Advances in OCT Murray Fingeret, OD
|
|
- Irene Johnson
- 5 years ago
- Views:
Transcription
1 Disclosures Advances in OCT Murray Fingeret, OD Consultant Alcon, Allergan, Bausch & Lomb, Carl Zeiss Meditec, Diopsys, Heidelberg Engineering, Reichert, Topcon Currently Approved OCT Devices OCT Devices FDA Approved in US Full approval including NDB Optovue RTVue, Avanti and ivue Carl Zeiss Meditec Cirrus and Cirrus Photo Heidelberg Spectralis RNFL only Only instrument, No Normative Database Topcon 3D-2000 Nidek RS-3000 Advance Optos OCT SLO Bioptigen OCT Imaging Fovea To Disc Angle (FOD) Fovea to Disc angle measurement varies among healthy individuals and the foveal position in relation to the optic nerve head might cause asymmetry in the distribution of the RNFL On average in healthy individuals, the fovea is located 6.3 ±3.0 vertically below the optic disc disc Heidelberg is the only company that currently compensates for this Other companies did not find it a factor No evidence that compensating for the foveal position relative to the OD will improve variability or ability to detect glaucoma Improves variability in one sector but makes it worse in another Position of Retinal Blood Vessels - evaluate 1
2 OCT Imaging OCT Imaging The circumpapillary retinal nerve fiber layer (RNFL) thickness profile shows a double hump pattern, with its peak in the superior and inferior quadrants Glaucoma is characterized by a loss of retinal ganglion cells and their axons and consequently by a reduction of circumpapillary RNFL thickness RNFL thickness measurements support the diagnosis of glaucoma by comparing the resulting RNFL thickness profiles with normative values derived from a healthy population However, considerable variation in RNFL thickness profiles exists in the normal population Known factors determining RNFL distribution are retinal blood vessel position, age, ethnicity, sex, axial length, optic disc (OD) area and refractive error Retinal blood vessel distribution (RVD) may also influence on the RNFL thickness profile and responsible for inter-subject variability Currently OCT s are not able to take into account blood vessels in the RNFL measurements Blood vessels are included in RNFL measurement no matter where they are located In future, it is important to assess RVD as an important anatomical factor responsible for inter-subject variability in circumpapillary RNFL measurements One possibility is to remove BV from RNFL before measurement is taken Advantages of Flipping the RNFL Use All the Parts of the Printout to Evaluate the RNFL RNFL Analysis is the Most Important Part of the OCT Printout TSNIT was an arbitrary designation 25 years ago Temporal region is most important part of curve and with NITSN, region is not broken up and loss more obvious Easier to recognize structure-function correlation RNFL loss correlates easily with field loss Easier to understand if macula area may be involved and central field loss present Is there a reduction in RNFL within the central 8 0 RNFL - Two Methods for Display 2
3 There is a Benefit to See Where the Measurement Falls with the Normative Range Optic Disc Analysis How is the rim tissue identified? What is the disc margin? Optic Disc Analysis How Does An Instrument Decide on Optic Disc Size? Use Bruch s Membrane Opening (BMO) Use BMO with New parameter- Minimal Rim Width (MRW) Both Cirrus and Spectralis use this metric Line drawn perpendicular from BMO to Rim 3
4 A new method for documentation of optic nerve & peripapillary anatomical structure Burgoyne, Chauhan, & colleagues reminded us all that 3-D is better than 2-D The clinically perceived disc margin is most likely not the innermost edge of Bruch s membrane detected by SD-OCT. (Ophthalmology APR2012) Minimal Rim Width New Metric to Assess Optic Disc BMO-MRW (minimum rim width based upon BM opening) quantifies the neuroretinal rim from a true anatomical outer border... (IOVS APR2012) Macula Testing in Glaucoma Imaging to detect glaucoma damage has concentrated around RNFL and optic nerve evaluation Complicating the assessment of the optic nerve when evaluating for glaucoma damage is: High variability of the ONH size and shape Even among healthy individuals Wide range of optic cup shapes and sizes Variable size and configuration of blood vessels Variable angle of penetration into the eyeball of the optic nerve (tilted disc) Parapapillary changes such as atrophy These are the reasons why it is difficult to detect early glaucomatous damage Macula Testing in Glaucoma Imaging allows measurement of features that are not possible otherwise Imaging can detect changes in the macular region The eye has about 1 million retinal ganglion cells, and their numbers are densest in the macula about six cells deep About 50% of ganglion cells are in the central 4.5 mm of the retina an area that represents only 7% of the total retinal area This area is not well covered in most visual field testing Measuring the ganglion cell complex directly (ILM IPL) Inner retinal layers and provides complete Ganglion cell assessment: Nerve fiber layer (g-cell axons) Ganglion cell layer (g-cell body) Inner plexiform layer (g-cell dendrites) What is EDI? Enhanced Depth Imaging For spectral domain, sensitivity is highest at top of window (vitreous) and declines with depth With EDI, sensitivity in window is flipped and now sensitivity is higher on bottom (lamina or choroid) Loss of sensitivity at top (vitreous) Advantage of swept source is less drop off in sensitivity with depth of imaging Valuable to examine lamina cribosa visibility All OCTs have ability to shift sensitivity with depth Images courtesy of Dr. Ou Tan, USC 4
5 Blood Flow Measurements using Spectral Domain OCT OCT Angiography Measuring Blood Flow Ocular blood flow and optic nerve injury have been linked The question still not answered is which comes first Can a device be developed that provides reproducible, quantitative, objective assessment of retinal and optic nerve blood flow Both global and local Does not require expert operator Measurement should correlate with structure and function Measuring Blood Flow There have been numerous devices to measure blood flow over the years Varying degrees of invasiveness, accuracy and precision From injectable dyes to ultrasonography to laser Poorly reproducible or variations in acquisition of data Optical Coherence Tomography Angiography Used to map retinal and superficial optic nerve vasculature and blood flow Not clear if there is a floor effect Is technique useful from early to advanced disease? SDOCT measurements are highly reproducible. 2-4 Steps in Range We can measure multiple steps of statistically significant change while a glaucoma suspect still is in the green normal range. Normal significance Limits for Average RNFLT 95th percentile = 107 microns 50th percentile = 89 microns 5 th percentile = 75 microns 1 st percentile = 67 microns Leung et al. Ophthalmology 2009;116:1257 Roh et al. Ophthalmology 2013;120:969 Wong et al. Optom Vis Sci 2014;92 Matlatch et al, IOVS Sep Risk of Disability <50 microns Values shown are for a 69 year old normal. 5
6 6
New Technologies in Glaucoma Management: From ERG to OCT
What s New and What s Next in Glaucoma New Technologies in Glaucoma Management: From ERG to OCT Ben Gaddie, OD FAAO Murray Fingeret, OD FAAO IOP 24- Hour IOP Role of hysteresis in glaucoma risk Cerebrospinal
More informationStructural examina.on: Imaging
ManaMa: Glaucoma Structural examina.on: Imaging Luís Abegão Pinto, MD, PhD Department of Ophthalmology CHLC Lisbon Faculty of Medicine, Lisbon University 1 11-10- 2013 Structural changes Qualitative changes
More informationMark Dunbar: Disclosure
Important Things to Understand About OCT Mark T. Dunbar, O.D., F.A.A.O. Bascom Palmer Eye Institute University of Miami, School of Medicine Mark Dunbar: Disclosure Optometry Advisory Board for: Allergan
More informationHow to Be Efficient and Effective. Disclosure. Topics CASE CM. Case JF 2007 OHTN / POAG? How to Be Efficient and Effective with. with New Technology
How to Be Efficient and Effective with Disclosure COPE Course ID: 40750 GL Michael Chaglasian has the following disclosures: 1. Advisory Board: Allergan, Inc., Alcon Labs, B+L Carl Zeiss Meditec 2. Research:
More information8/6/17. Disclosures Aerie Pharmaceuticals Alcon BioTissue Diopsys Optovue Shire
Nathan Lighthizer, O.D., F.A.A.O. Associate Professor Assistant Dean for Clinical Care Director of Continuing Education Chief of Specialty Care Clinics Oklahoma College of Optometry Tahlequah, OK lighthiz@nsuok.edu
More informationIl contributo dell'angio-oct: valutazione integrata della componente nervosa e vascolare della malattia glaucomatosa
SIMPOSIO G.O.A.L. - LE NUOVE FRONTIERE DIAGNOSTICHE E LE LINEE DI INDIRIZZO AMBULATORIALI DEL GLAUCOMA Coordinatore e moderatore: D. Mazzacane Presidente: L. Rossetti Il contributo dell'angio-oct: valutazione
More informationHistory/principles of the OCT What does the normal retinal OCT look like Vitreal disorders Retinal/RPE disorders Choroidal disorders
Nathan Lighthizer, O.D., F.A.A.O. Assistant Professor Assistant Dean for Clinical Care Director of Continuing Education Chief of Specialty Care Clinics Chief of Electrodiagnostics Clinic Oklahoma College
More informationSTRUCTURE & FUNCTION An Integrated Approach for the Detection and Follow-up of Glaucoma. Module 3a GDx
STRUCTURE & FUNCTION An Integrated Approach for the Detection and Follow-up of Glaucoma Module 3a GDx Educational Slide Deck Carl Zeiss Meditec, Inc. November 2005 1 Structure & Function Modules Module
More informationCirrus TM HD-OCT. Details defi ne your decisions
Cirrus TM HD-OCT Details defi ne your decisions 2 With high-defi nition OCT Carl Zeiss Meditec takes you beyond standard spectral domain Built on 10 years experience at the vanguard of innovation, Carl
More informationNew Concepts in Glaucoma Ben Gaddie, OD Moderator Murray Fingeret, OD Louis Pasquale, MD
New Concepts in Glaucoma Ben Gaddie, OD Moderator Murray Fingeret, OD Louis Pasquale, MD New Concepts in Glaucoma Optical Coherence Tomography: Is it necessary and needed to diagnose and monitor glaucoma?
More informationGlaucoma Pearls and Grand Rounds Vision Expo East 2016
Glaucoma Pearls and Grand Rounds Vision Expo East 2016 Murray Fingeret, Ben Gaddie, Richard Madonna Disclosures Murray Fingeret - Consultant Alcon, Allergan, Bausch & Lomb, Carl Zeiss Meditec, Dyopsys,
More informationOptical Coherence Tomography (OCT)
Understanding and Interpreting OCT Mark Dunbar: Disclosure The Swiss Army Pocket Knife of Eye Care Mark T. Dunbar, O.D., F.A.A.O. Bascom Palmer Eye Institute University of Miami, School of Medicine Consultant
More informationCirrus TM HD-OCT. Details define your decisions
Cirrus TM HD-OCT Details define your decisions 2 With high-definition OCT Carl Zeiss Meditec takes you beyond standard spectral domain Built on 10 years experience at the vanguard of innovation, Carl Zeiss
More informationAutomated Visual Field Analysis for Glaucoma
Island of Vision Automated Visual Field Analysis for Glaucoma Normal Visual Field Parameters 60 superior 60 nasal 75 inferior 100 temporal Macula the central 13 Fovea the central 3 Visual field is limited
More informationGanglion cell complex scan in the early prediction of glaucoma
Original article in the early prediction of glaucoma Ganekal S Nayana Super Specialty Eye Hospital and Research Center, Davangere, Karnataka, India Abstract Objective: To compare the macular ganglion cell
More informationEvolving glaucoma management True diagnostic integration for the preservation of vision
Evolving glaucoma management True diagnostic integration for the preservation of vision // GLAUCOMA MANAGEMENT MADE BY ZEISS The moment you are certain it is glaucoma. This is the moment we work for. There
More informationOCT Interpretation in Retinal Disease
OCT Interpretation in Retinal Disease Jay M. Haynie, OD, FAAO Financial Disclosure I have received honoraria or am on the advisory board for the following companies: Carl Zeiss Meditec Advanced Ocular
More informationIncorporating OCT Angiography Into Patient Care
Incorporating OCT Angiography Into Patient Care Beth A. Steele, OD, FAAO OCT A: Introduction Isolates microvascular circulation from OCT image data Axial resolution = 5 microns (i.e. fine capillaries visible)
More informationOtticaFisiopatologica
Anno quindicesimo dicembre 2010 How to assess the retinal nerve fiber layer thickness Antonio Ferreras Miguel Servet University Hospital, Zaragoza. Aragón Health Sciences Institute University of Zaragoza
More informationReproducibility of Bruch Membrane Opening-Minimum Rim Width Measurements With Spectral Domain Optical Coherence Tomography
ORIGINAL STUDY Reproducibility of Bruch Membrane Opening-Minimum Rim Width Measurements With Spectral Domain Optical Coherence Tomography Keunheung Park, MD,* Jinmi Kim, PhD, and Jiwoong Lee, MD, PhD*
More informationTitle: OCT Analysis Workshop: Interpretation of OCT printouts
Title: OCT Analysis Workshop: Interpretation of OCT printouts Authors: David Yang, OD, FAAO Staff Optometrist, VA Palo Alto Health Care System Associate Clinical Professor, UC Berkeley School of Optometry
More informationIntroducing ANGIOVUE ESSENTIAL. Built on the Avanti Widefield OCT Platform. OCT Angiography for Primary Eye Care
Introducing ANGIOVUE ESSENTIAL Built on the Avanti Widefield OCT Platform OCT Angiography for Primary Eye Care Transform Your View of the Retina OCT Angiography (OCTA) is a quick non-invasive test that
More informationRetinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography
Original Article Philippine Journal of OPHTHALMOLOGY Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography Dennis L. del Rosario, MD and Mario M. Yatco, MD University of Santo
More informationInternational Journal of Scientific & Engineering Research, Volume 4, Issue 12, December ISSN
International Journal of Scientific & Engineering Research, Volume 4, Issue 12, December-2013 108 Name of Chief and Corresponding Author : Dr Chandrima Paul TITLE : Comparison of glaucoma diagnostic ability
More informationGlaucoma Diagnosis. Definition of Glaucoma. Diagnosing Glaucoma. Vision Institute Annual Fall Conference
Glaucoma Diagnosis Vision Institute Annual Fall Conference Mitchell W. Dul, OD, MS, FAAO mdul@sunyopt.edu Richard J. Madonna, MA, OD, FAAO rmadonna@sunyopt.edu Definition of Glaucoma Glaucoma can be regarded
More informationSOUTH-EAST EUROPEAN JOURNAL of OPHTHALMOLOGY 2015; 1 (1) 34 40
Review article SOUTH-EAST EUROPEAN JOURNAL of OPHTHALMOLOGY 2015; 1 (1) 34 40 Retinal nerve fiber layer versus peripapillary capillary density assessment A powerful tool for detecting optic nerve head
More informationAvailable online at Pelagia Research Library. Advances in Applied Science Research, 2013, 4(6):
Available online at www.pelagiaresearchlibrary.com Advances in Applied Science Research, 2013, 4(6):201-206 ISSN: 0976-8610 CODEN (USA): AASRFC Comparison of glaucoma diagnostic ability of retinal nerve
More informationOptical Coherence Tomography (OCT) in Uveitis Piergiorgio Neri, BMedSc, MD, PhD Head Ocular Immunology Unit
The Eye Clinic Polytechnic University of Marche Head: Prof Alfonso Giovannini November, 1991 Optical Coherence Tomography (OCT) in Uveitis Piergiorgio Neri, BMedSc, MD, PhD Head Ocular Immunology Unit
More informationOCT in the Diagnosis and Follow-up of Glaucoma
OCT in the Diagnosis and Follow-up of Glaucoma Karim A Raafat MD. Professor Of Ophthalmology Cairo University Hmmmm! Do I have Glaucoma or not?! 1 Visual Function 100% - N Gl Structure : - 5000 axon /
More informationWhat Is O.C.T. and Why Should I Give A Rip? OCT & Me How Optical Coherence Tomography Changed the Life of a Small Town Optometrist 5/19/2014
OCT & Me How Optical Coherence Tomography Changed the Life of a Small Town Optometrist Email: myoder@wcoil.com Mark A. Yoder, O.D. 107 N. Main Street PO Box 123 Bluffton, OH 45817 @yoderod 115.02 Histoplasma
More informationTo assess the glaucoma diagnostic ability of Fourier Domain Optical Coherence Tomography
American Journal of Engineering Research (AJER) e-issn : 2320-0847 p-issn : 2320-0936 Volume-02, Issue-11, pp-104-110 www.ajer.org Research Paper Open Access To assess the glaucoma diagnostic ability of
More informationGanglion cell analysis by optical coherence tomography (OCT) Jonathan A. Micieli, MD Valérie Biousse, MD
Ganglion cell analysis by optical coherence tomography (OCT) Jonathan A. Micieli, MD Valérie Biousse, MD Figure 1. Normal OCT of the macula (cross section through the line indicated on the fundus photo)
More informationMacular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma
Med. J. Cairo Univ., Vol. 83, No. 2, September: 67-72, 2015 www.medicaljournalofcairouniversity.net Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma
More informationMethod for comparing visual field defects to local RNFL and RGC damage seen on frequency domain OCT in patients with glaucoma.
Method for comparing visual field defects to local RNFL and RGC damage seen on frequency domain OCT in patients with glaucoma. Donald C. Hood 1,2,* and Ali S. Raza 1 1 Department of Psychology, Columbia
More informationOCT Angiography. Financial Disclosures: Pre-Test: Which one is Correct?
OCT Angiography Brandon Lujan, MD Medical Director, Casey Reading Center Assistant Professor of Ophthalmology Financial Disclosures: Genentech (Consultant, Grant support, Educational training) UC Berkeley
More informationSwept-Source OCT Angiography: SS OCT Angio TM
Swept-Source OCT Angiography: SS OCT Angio TM Not available in all countries, please check with your distributor. 2015.09 Swept-Source OCT Angiography: SS OCT Angio TM Introduction Optical coherence tomography
More informationFinancial Disclosure. Maximizing OCT in Diagnosis and Management of Glaucoma. Case 1: Dennis, 65yo WM DIAGNOSIS: CASES 1 2 7/29/2016
Financial Disclosure Maximizing OCT in Diagnosis and Management of Glaucoma Aerie Pharmaceuticals Alcon Laboratories Allergan Carl Zeiss Meditec Danica J. Marrelli, OD, FAAO AAO Diplomate, Glaucoma University
More informationOptical coherence tomography (OCT) is a relatively new noninvasive. The Use of Optical Coherence Tomography in Neurology DIAGNOSTIC UPDATE
DIAGNOSTIC UPDATE The Use of Optical Coherence Tomography in Neurology Cédric Lamirel, MD,* Nancy Newman, MD,* Valérie Biousse, MD* Departments of *Ophthalmology, Neurology, and Neurological Surgery, Emory
More informationtracking progression we can better manage our patients. Like any tool, any instrument you ve got to
EIYESS ALBEINUTI, MD 1 As we know OCT has become very instrumental in taking care of glaucoma patients whether we have the ability to objectively image the RNFL and therefore pickup earlier signs of damage
More informationGlaucoma: a disease of the macula?
Glaucoma: a disease of the macula? Derek MacDonald, OD, FAAO Waterloo, Ontario, Canada Please silence all mobile devices and remove items from chairs so others can sit. Unauthorized recording of this session
More informationNoel de Jesus Atienza, MD, MSc and Joseph Anthony Tumbocon, MD
Original Article Philippine Journal of OPHTHALMOLOGY Diagnostic Accuracy of the Optical Coherence Tomography in Assessing Glaucoma Among Filipinos. Part 1: Categorical Outcomes Based on a Normative Database
More informationEnhanced structure-function relationship in glaucoma with an anatomically and geometrically accurate neuroretinal rim measurement
Enhanced structure-function relationship in glaucoma with an anatomically and geometrically accurate neuroretinal rim measurement Item Type Article Authors Danthurebandara, V.M.; Sharpe, G.P.; Hutchison,
More informationOCT & Optic nerve. Pr. Jean-Philippe Nordmann Glaucoma Centre - Hôpital des Quinze-Vingts, Paris
OCT & Optic nerve Pr. Jean-Philippe Nordmann Glaucoma Centre - Hôpital des Quinze-Vingts, Paris Edition Published by: Laboratoire Théa 12 rue Louis Blériot 63000 Clermont-Ferrand - France Tel: 04 73 98
More informationGlaucoma Diagnosis & Tracking with Optical Coherence Tomography
Glaucoma Diagnosis & Tracking with Optical Coherence Tomography David Huang, MD, PhD Charles C. Manger III, MD Chair of Corneal Laser Surgery Assoc. Prof. of Ophthalmology & Biomedical Engineering Doheny
More informationCorporate Medical Policy
Corporate Medical Policy Glaucoma, Evaluation by Ophthalmologic Techniques File Name: Origination: Last CAP Review: Next CAP Review: Last Review: glaucoma_evaluation_by_ophthalmologic_techniques 3/2001
More informationC a t a r a c t G l a u c o m a R e t i n a R e f r a c t i v e. The GDxVCC Early answers and ongoing assessment for glaucoma
C a t a r a c t G l a u c o m a R e t i n a R e f r a c t i v e The GDxVCC Early answers and ongoing assessment for glaucoma The quantifiable approach to quality care Only Humphrey GPA software Early insight
More informationStructural & Functional Optical Coherence Tomography for Glaucoma Diagnosis
Congreso Argentino de Oftalmologia, May 2009, Buenos Aires Structural & Functional Optical Coherence Tomography for Glaucoma Diagnosis David Huang, MD, PhD Assoc. Prof. of Ophthalmology & Biomedical Engineering
More informationUniversity Hospital Basel. Optical Coherence Tomography Emerging Role in the Assessment of MS PD Dr. Konstantin Gugleta
University Hospital Basel Optical Coherence Tomography Emerging Role in the Assessment of MS PD Dr. Konstantin Gugleta 15th State of the Art SMSS, Lucerne January 2013 Retinal Nerve Fiber Layer 1.200.000
More informationCourse # Getting to Know Your OCT
Course # 140 Getting to Know Your OCT Course Title: Lecturer: Getting to Know Your OCT Brad Sutton, OD, FAAO IU School of Optometry Financial Disclosures No financial disclosures Optical Coherence Tomography-OCT
More informationThe Measure of Confidence
Heidelberg_936357.qxd:Layout 1 5/9/08 12:01 PM 12:02 Page 1 (Cyan (Magenta (Yellow (Black (UV Five Powerful Solutions to Fit Your Practice PowerCheck Glaucoma FastCheck+ GPS Software and Retina Edema Index
More informationGlaucoma Evaluation. OCT Pearls for Glaucoma. OCT: Retinal Nerve Fiber Layer. Financial Disclosures. OCT: Macula. Case Example
OCT Pearls for Glaucoma using OCT of the macula for glaucoma Glaucoma Evaluation Right eye Visual Acuity 20/25 20/25 IOP 13 13 Central corneal 530 530 thickness Anterior exam Normal with PCIOL Normal with
More informationPRIMUS 200 from ZEISS The essential OCT
PRIMUS 200 from ZEISS The essential OCT Seeing beyond the surface. ZEISS PRIMUS 200 // INNOVATION MADE BY ZEISS Clear Visualization. Advanced Technology. Reliability. Essential elements of your first OCT.
More informationRetinal nerve fiber layer thickness in Indian eyes with optical coherence tomography
Original articles in Indian eyes with optical coherence tomography Malik A, Singh M, Arya SK, Sood S, Ichhpujani P Department of Ophthalmology Government Medical College and Hospital, Sector 32, Chandigarh,
More informationPRIMUS 200 from ZEISS The essential OCT
EN 00_00I The contents of the brochure may differ from the current status of approval of the product in your country. Please contact your regional representative for more information. Subject to change
More informationSeiji T. Takagi, Yoshiyuki Kita, Asuka Takeyama, and Goji Tomita. 1. Introduction. 2. Subjects and Methods
Ophthalmology Volume 2011, Article ID 914250, 5 pages doi:10.1155/2011/914250 Clinical Study Macular Retinal Ganglion Cell Complex Thickness and Its Relationship to the Optic Nerve Head Topography in Glaucomatous
More informationOPTOMETRY RESEARCH PAPER
C L I N I C A L A N D E X P E R I M E N T A L OPTOMETRY RESEARCH PAPER Interocular symmetry of retinal nerve fibre layer thickness in healthy eyes: a spectral-domain optical coherence tomographic study
More informationComparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements
Original article Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements Dewang Angmo, 1 Shibal Bhartiya, 1 Sanjay K Mishra,
More informationThe World s fastest OCT. As simple as pressing. the start button
The World s fastest OCT As simple as pressing the start button lution continues Optopol engineering team, designers of the first commercially available Spectral Domain OCT in the world, are proud to present
More informationOCT Image Analysis System for Grading and Diagnosis of Retinal Diseases and its Integration in i-hospital
Progress Report for1 st Quarter, May-July 2017 OCT Image Analysis System for Grading and Diagnosis of Retinal Diseases and its Integration in i-hospital Milestone 1: Designing Annotation tool extraction
More informationConfocal Adaptive Optics Imaging of Peripapillary Nerve Fiber Bundles: Implications for Glaucomatous Damage Seen on Circumpapillary OCT Scans
Article DOI: 10.1167/tvst.4.2.12 Confocal Adaptive Optics Imaging of Peripapillary Nerve Fiber Bundles: Implications for Glaucomatous Damage Seen on Circumpapillary OCT Scans Donald C. Hood 1, Monica F.
More informationComparison of cross sectional optical coherence tomography images of elevated optic nerve heads across acquisition devices and scan protocols
Patel et al. Eye and Vision (2018) 5:17 https://doi.org/10.1186/s40662-018-0112-3 RESEARCH Open Access Comparison of cross sectional optical coherence tomography images of elevated optic nerve heads across
More information1/25/2019 OCT & OCTA RETINAL IMAGING: HOW TO PREVENT RAGING GLAUCOMA! THE ORIGINAL RAGING GLAUCOMA OCT RETINAL IMAGING OPTIC NERVE HEAD EXAMINATION
OCT & OCTA RETINAL IMAGING: HOW TO PREVENT RAGING GLAUCOMA! Craig Thomas, O.D. 3900 West Wheatland Road Dallas, Texas 75237 972-780-7199 thpckc@yahoo.com THE ORIGINAL RAGING GLAUCOMA 47-year-old Black
More informationVisualize. Analyze. Personalize. OCT + OCTA
Visualize. Analyze. Personalize. OCT + OCTA A New Approach to Protecting Vision AngioVue OCT Angiography brings valuable new information to clinical practice. Non-invasive visualization of retinal vasculature.
More informationVisualize. Analyze. Personalize. OCT + OCTA. with
Visualize. Analyze. Personalize. OCT + OCTA with Avanti Widefield OCT with AngioVue OCTA Imaging Comprehensive Structural and Functional Imaging in a Single Imaging Platform Comprehensive OCT Imaging The
More informationNew Normative Database of Inner Macular Layer Thickness Measured by Spectralis OCT Used as Reference Standard for Glaucoma Detection
Article https://doi.org/10.1167/tvst.7.1.20 New Normative Database of Inner Macular Layer Thickness Measured by Spectralis OCT Used as Reference Standard for Glaucoma Detection María Nieves-Moreno 1,2,
More informationRates of Abnormal Retinal Nerve Fiber Layer and Ganglion Cell Layer OCT Scans in Healthy Myopic Eyes: Cirrus Versus RTVue
CLINICAL SCIENCE Rates of Abnormal Retinal Nerve Fiber Layer and Ganglion Cell Layer OCT Scans in Healthy Myopic Eyes: Cirrus Versus RTVue Jean-Claude Mwanza, MD, MPH, PhD; Fouad E. Sayyad, MD; Ahmad A.
More informationSOCT Copernicus REVO. * - Currently import and overlay are avaibale in manual mode only
SOCT Copernicus REVO Easy Operation (Full auto & Auto mode) Auto alignment (Z-position, C-gate, Focus, Tomogram) Voice guide (support patient through examination) Powerful analysis tools Enhanced tomograms
More informationRETINA REVEALED. Dynamic Developments in AMD Diagnosis and Treatment (2014) The Dawn of: Pharmaco-Genetics (aka Nutrigenomics) Jerome Sherman, OD
RETINA REVEALED Dynamic Developments in AMD Diagnosis and Treatment (2014) The Dawn of: Pharmaco-Genetics (aka Nutrigenomics) Jerome Sherman, OD Disclosures: Jerome Sherman Dr. Sherman has lectured, received
More informationOCT Angiography in Primary Eye Care
OCT Angiography in Primary Eye Care An Image Interpretation Primer Julie Rodman, OD, MS, FAAO and Nadia Waheed, MD, MPH Table of Contents Diabetic Retinopathy 3-6 Choroidal Neovascularization 7-9 Central
More informationStructure WGA. Structure WGA. Structural Assessment in Glaucoma. What s New
New Developments in the Structural and Functional Assessment of the Glaucomas John G. Flanagan PhD, MCOptom, FAAO Professor, School of Optometry, University of Waterloo Professor, Dept of Ophthalmol &
More informationA spectral-domain OCT study of formerly premature children. Prat Itharat MD May 30, 2008 Vanderbilt Eye Institute Preceptor: Dr.
A spectral-domain OCT study of formerly premature children. Prat Itharat MD May 30, 2008 Vanderbilt Eye Institute Preceptor: Dr. Recchia Background: Optical coherence tomography (OCT) OCT analogous to
More informationMATERIALS AND METHODS
Glaucoma Analysis of Peripapillary Retinal Nerve Fiber Distribution in Normal Young Adults Seung Woo Hong, 1,2 Myung Douk Ahn, 2 Shin Hee Kang, 1,3 and Seong Kyu Im 1,4 PURPOSE. To determine the anatomic
More informationEarly Detection Of Glaucoma Clinical Clues. Points To Live By. Glaucoma Risk Factors 10/3/2014
Early Detection Of Glaucoma Clinical Clues Eric E. Schmidt, O.D. Omni Eye Specialists Wilmington, NC schmidtyvision@msn.com Points To Live By 25% of G pxs NEVER have IOP >21mm 50% of G pxs have trough
More informationJong Chul Han, Da Ye Choi, and Changwon Kee. 1. Introduction
Ophthalmology Volume 2015, Article ID 641204, 7 pages http://dx.doi.org/10.1155/2015/641204 Clinical Study The Different Characteristics of Cirrus Optical Coherence Tomography between Superior Segmental
More informationDeterminants of Optical Coherence Tomography Derived Minimum Neuroretinal Rim Width in a Normal Chinese Population
Glaucoma Determinants of Optical Coherence Tomography Derived Minimum Neuroretinal Rim Width in a Normal Chinese Population Tin A. Tun, 1 Chen-Hsin Sun, 2,3 Mani Baskaran, 1,2,4 Michael J. A. Girard, 1,5
More informationA Review Of Risk Factors. Early Detection Of Glaucoma Clinical Clues. A risk factor analysis is critical. Points To Live By
A Review Of Risk Factors Early Detection Of Glaucoma Clinical Clues Eric E. Schmidt, O.D. Omni Eye Specialists Wilmington, NC schmidtyvision@msn.com FINDACAR Family history IOP Nearsightedness Diabetes/Vascular
More informationRETINAL NERVE FIBER LAYER
CLINICAL SCIENCES The Effect of Scan Diameter on Retinal Nerve Fiber Layer Thickness Measurement Using Stratus Optic Coherence Tomography Giacomo Savini, MD; Piero Barboni, MD; Michele Carbonelli, MD;
More informationResearch Article Repeatability of Perimacular Ganglion Cell Complex Analysis with Spectral-Domain Optical Coherence Tomography
Ophthalmology Volume 2015, Article ID 605940, 5 pages http://dx.doi.org/10.1155/2015/605940 Research Article Repeatability of Perimacular Ganglion Cell Complex Analysis with Spectral-Domain Optical Coherence
More informationMoving forward with a different perspective
Moving forward with a different perspective The Leader In Vision Diagnostics Offers A New Perspective Marco has served the eyecare community by offering exceptional lane products and automated high tech
More informationThe optic nerve head ONH) is an important anatomic
Glaucoma Deep Optic Nerve Head Morphology Is Associated With Pattern of Glaucomatous Visual Field Defect in Open-Angle Glaucoma Jong Chul Han, Jae Hwan Choi, Do Young Park, Eun Jung Lee, and Changwon Kee
More informationOptical Coherence Tomography Imaging for Glaucoma Today and Tomorrow. Christopher Kai-Shun Leung
REVIEW ARTICLE Optical Coherence Tomography Imaging for Glaucoma Today and Tomorrow Christopher Kai-Shun Leung Abstract: Digital imaging technologies for glaucoma diagnostics have evolved rapidly over
More informationNIH Public Access Author Manuscript Br J Ophthalmol. Author manuscript; available in PMC 2010 April 29.
NIH Public Access Author Manuscript Published in final edited form as: Br J Ophthalmol. 2009 August ; 93(8): 1057 1063. doi:10.1136/bjo.2009.157875. Retinal nerve fibre layer thickness measurement reproducibility
More informationOptical Coherence Tomography: Pearls for the Anterior Segment Surgeon Basic Science Michael Stewart, M.D.
Optical Coherence Tomography: Pearls for the Anterior Segment Surgeon Basic Science Michael Stewart, M.D. Disclosure OCT Optical Coherence Tomography No relevant financial relationships I will refer to
More informationPosition of retinal blood vessels correlates with retinal nerve fibre layer thickness profiles as measured with GDx VCC and ECC
Department of Ophthalmology, Medical University of Vienna, Austria Correspondence to Clemens Vass, Department of Ophthalmology and Optometry, Medical University of Vienna, General Hospital, Währinger Gürtel
More informationCorrespondence should be addressed to Verena Prokosch;
Hindawi Ophthalmology Volume 2017, Article ID 8014294, 6 pages https://doi.org/10.1155/2017/8014294 Research Article Comparison between the Correlations of Retinal Nerve Fiber Layer Thickness Measured
More informationReproducibility of Choroidal Thickness Measurements Across Three Spectral Domain Optical Coherence Tomography Systems
Reproducibility of Choroidal Thickness Measurements Across Three Spectral Domain Optical Coherence Tomography Systems The MIT Faculty has made this article openly available. Please share how this access
More information53 year old woman attends your practice for routine exam. She has no past medical history or family history of note.
Case 1 Normal Tension Glaucoma 53 year old woman attends your practice for routine exam. She has no past medical history or family history of note. Table 1. Right Eye Left Eye Visual acuity 6/6 6/6 Ishihara
More informationMeasurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1000 Spectral Domain Optical Coherence Tomography
pissn: 111-8942 eissn: 292-9382 Korean J Ophthalmol 212;26(4):255-259 http://dx.doi.org/1.3341/kjo.212.26.4.255 Original Article Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1 Spectral
More informationCLINICAL SCIENCES. Felipe A. Medeiros, MD; Linda M. Zangwill, PhD; Christopher Bowd, PhD; Robert N. Weinreb, MD
CLINICAL SCIENCES Comparison of the GDx VCC Scanning Laser Polarimeter, HRT II Confocal Scanning Laser Ophthalmoscope, and Stratus OCT Optical Coherence Tomograph for the Detection of Glaucoma Felipe A.
More informationAngio-OCT. Degenerazione Maculare Legata all Eta. Giuseppe Querques
Angio-OCT Degenerazione Maculare Legata all Eta Giuseppe Querques Department of Ophthalmology, IRCCS Ospedale San Raffaele, University Vita Salute San Raffaele, Milan, Italy Financial Disclosure ADVISORY
More informationTranslating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects
Romanian Journal of Ophthalmology, Volume 60, Issue 3, July-September 2016. pp:158-164 GENERAL ARTICLE Translating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects
More informationObjective Assessment of Macula and Optic Nerve
Objective Assessment of Macula and Optic Nerve Jerry Sherman Disclosure: Dr. Sherman has lectured and received honorarium from Carl Zeiss Meditec, Topcon, Optovue, Optos, and PHP, Diopsys, Eye Solutions,Quantel,
More informationOptical coherence tomography (OCT) is an imaging
Glaucoma Adjusting Circumpapillary Retinal Nerve Fiber Layer Profile Using Retinal Artery Position Improves the Structure Function Relationship in Glaucoma Yuri Fujino, 1 Takehiro Yamashita, 2 Hiroshi
More informationDiagnostic Accuracy of the Optical Coherence Tomography in Assessing Glaucoma Among Filipinos. Part 2: Optic Nerve Head and Retinal
Original Article Philippine Journal of OPHTHALMOLOGY Diagnostic Accuracy of the Optical Coherence Tomography in Assessing Glaucoma Among Filipinos. Part 2: Optic Nerve Head and Retinal Nerve Fiber Layer
More informationComparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis OCT
pissn: 1011-8942 eissn: 2092-9382 Korean J Ophthalmol 2011;25(3):166-173 DOI: 10.3341/kjo.2011.25.3.166 Original Article Comparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis
More informationOCT Angiography The Next Frontier
Choroid Retina avascular 5/13/2017 OCT Angiography The Next Frontier Pierce Kenworthy OD, FAAO June 9, 2017 OCT Angiography (OCTA) 2016 Non-invasive, motion contrast imaging Represents erythrocyte movement
More informationDeeper visualizations for intervening with confidence.
CIRRUS OCT with AngioPlex from ZEISS Making the revolutionary routine New vascular quantification Deeper visualizations for intervening with confidence. CIRRUS OCT with AngioPlex from ZEISS can be a much
More informationOCT Angiography. SriniVas Sadda, MD
OCT Angiography SriniVas Sadda, MD Professor of Ophthalmology Director, Medical Retina Unit Ophthalmic Imaging Unit University of Southern California Los Angeles, California, USA Disclosure Consulting
More informationResearch Article The Pattern of Retinal Nerve Fiber Layer and Macular Ganglion Cell-Inner Plexiform Layer Thickness Changes in Glaucoma
Hindawi Ophthalmology Volume 2017, Article ID 78365, 8 pages https://doi.org/10.1155/2017/78365 Research Article The Pattern of Retinal Nerve Fiber Layer and Macular Ganglion Cell-Inner Plexiform Layer
More informationRelationship between the GDx VCC and Stratus OCT in Primary Open Angle Glaucoma
Relationship between the GDx VCC and Stratus OCT in Primary Open Angle Glaucoma Reza Zarei, MD 1 Mohammad Soleimani, MD 2 Sasan Moghimi, MD 3 Mohammad Yaser Kiarudi, MD 2 Mahmoud Jabbarvand, MD 1 Yadollah
More information