1 True IOP No Doubt Facts and Figures Figures and Facts Ziemer Ophthalmic Systems AG a Ziemer Group Company Allmendstrasse 11 CH-2562 Port, Switzerland

2 There is increasing evidence that DCT measures IOP more accurately than any other tonometer. F. Bochmann et al, Expert Review Ophthalmology 2010

3 The Early Manifest Glaucoma Trial showed that every millimeter of IOP reduction lowers the risk of glaucoma progression by 10 %. 1 However, the Goldmann applanation tonometer, which is current gold standard, is not precise enough to measure the true IOP within an error of 1 mmhg. 2 A recent in-vivo study including cannulation and IOP measurement in the anterior chamber has shown that PASCAL measurements are closest to the actual pressure in the chamber and that its accuracy is clearly superior to traditional Goldmann Tonometry (GAT). 4 This new method of corneal-independent tonometry allows the detection of more true ocular hypertensives and therefore more of the true glaucoma patients. 3 This reduces the risk for blindness due to late or missed diagnosis and treatment. a At 20 mmhg

4 The ideal tonometer is expected to be accurate, repeatable, reproducible, and minimally influenced by factors such as corneal properties and different examiners. A. Wang, L. Alencar, R. Weinreb et al., J Glaucoma 2011

5 PASCAL s clinical benefits True IOP No corneal influence Superior Precison Highest repeatability and reproducability Ocular Pulse Amplitude A measure for the short term pressure fluctuations Detect the real glaucoma suspects Less false negatives than applanation tonometry

6 25 IOP [mmhg] MMHG MMHG 0 5 PASCAL Intracameral 10 t [sec] Cannulation study by A. Böhm; 2009: DCT measurements come close to the true IOP 4 Correlation of in-vivo direct manometric measurements (black curve) with simultaneous PASCAL DCT measurements (red curve) performed during cataract surgery in the study of A. Böhm 2009.

7 Accuracy True IOP! The accuracy of tonometric readings is defined by how close they come to the true IOP as measured intracamerally. This accuracy is an important criterion for tonometry as IOP measurements are critical elements in making sound treatment decisions. The PASCAL was validated by comparing its measurements with manometric readings in a large series of cannulated eyes with patients undergoing cataract surgery. A mean difference of DCT to true IOP of only -0.2 mmhg was found, at the level of 20 mmhg. Results of the original study from A. Böhm et al The concordance between true IOP and [DCT] measured IOP seems to be higher compared with the GAT meas urements, as CCT and other parameters had no clinically relevant effect, and therefore no correction of the IOP measurements [on DCT] was necessary. According to our data, the DCT measurements came close to the true IOP.

8 Correction nomograms that adjust GAT IOP based solely on CCT are neither valid nor useful in individual patients. R. Weinreb, J. Brandt, D. Garway Heath, F. Medeiros 2006, world Glaucoma consensus on IOP

9 Influence of corneal properties on GAT 4 th World Glaucoma Consensus on IOP 10 Consensus Points: Measurement of Intraocular Pressure: 1. On average, greater central corneal thickness (CCT) results in overestimation of intraocular pressure (IOP) as measured by Goldmann applanation tonometry (GAT). [ ] 2. Compared to GAT, CCT has a lesser effect on IOP measured by DCT and the OcularResponse Analyser (ORA), CCT has a greater effect on IOP measured by NCT and Rebound Tonometry. [ ] 6. A thick cornea gives rise to a greater probability of an IOP being over-estimated (and a thin cornea of an IOP being under-estimated), but the extent of measurement error in individual patients cannot be ascertained from the CCT alone. [ ] 8. The corneal modulus of elasticity likely has a greater effect on GAT IOP measurement error than CCT. R. Weinreb, J. Brandt, D. Garway Heath, F. Medeiros 2006

10 Correcting GAT-IOP for CCT, 31 % of patients with NTG could be reclassified as having POAG and 56 % with OHT as normal. Copt et al, Arch Ophthalmol. 1999

11 25 IOP [mmhg] DCT R 2 = GAT R 2 = 0.14 CCT [μm] Distribution of IOP relative to CCT 7 DCT, in contrast to GAT, is nearly independent of CCT. Correction of a single IOP value for CCT is not possible due to the heavy scatter. Correcting applanation IOP for Corneal Thickness (CCT) does not work as it can be seen in the heavy scatter of GAT values. In many cases corrections would work in the wrong direction and even magnify the error. Other factors like corneal rigidity influence the applanation measurement to probably even a bigger extent.

12 DCT-IOP is more closely related to extent of glaucoma damage than is Goldmann IOP. M. Sullivan Mee et al, J. Glaucoma 2007

13 [n] (total = 2175) Detecting the real glaucomas = 1.7 mmhg DCT GAT Correlating IOP with glaucomatous damage: Conclusion of a study from M. Sullivan Mee IOP [mmhg] Frequency Distribution of GAT-IOP and DCT-IOP eyes of primarliy Mexican ancestry showed a mean IOP between DCT and GAT of 1.7 mmhg. DCT is calibrated to true IOP while GAT was calibrated to cadaver eyes in the 1950s. These findings suggest that DCT-IOP is correlated with glaucomatous damage, and moreover, DCT-IOP is more closely related to extent of glaucoma damage than is Goldmann IOP (GAT-IOP). The most likely explanation for these results is that GAT-IOP systematically underestimates IOP compared with DCT-IOP. Our findings also support the hypothesis that corneal biomechanical factors other than CCT are major confounders of applanation tonometry measurements.

14 4.5 [mmhg] Intraobserver variability 4 [mmhg] Interobserver mean difference and 95 % limits of agreement DCT GAT ORA Repeat measurements by the same observer would be within these limits in 95 % of the measurements 5 Variability of non contact tonometers (NCT) was found to be twice as high compared to contact techniques. As NCT measure only over a period of milliseconds, they are influenced by the ocular pulse. Repeat measurements by different observers would be within these limits in 95 % of the measurements 5 PASCAL shows less variability than the traditional Gold Standard GAT and ORA, because its semiautomatic recording is highly independent from user and environmental influences.

15 Repeatability and Reproducibility The precision of a device is defined by its repeatability and reproducibility and is a measure of independency from any user interaction. High precision allows for the detection of a gradual IOP increase earlier in a highly refined IOP progression analysis. Precision is even more important to monitor IOP when several users are involved. Conclusion of the original study from A. Wang et al The results of this study suggest that the DCT demonstrates a reproducibility that is better than the GAT or the ORA. The better reproducibility of the DCT may result in more precise measurements for monitoring lop changes over time compared to GAT and ORA. Conclusion of the original study from A. Kotecha et al The PASCAL DCT shows excellent measurement precision, displaying the best repeatability and reproducibility of the 3 tonometers [ ]. (GAT, ORA, DCT)

16 IOP [mmhg] IOP [mmhg] DCT GAT ORA (non CC) 0 DCT GAT ΔIOP Controlgroup DCT GAT ΔIOP Trabeculectomy DCT GAT ΔIOP Prostaglandines IOP after LASIK 11 Surgery changes corneal biomechanics, not IOP. GAT and conventional Airpuffs give a false impression by underestimating IOP post-surgery while PASCAL stays unaffected. IOP in different treatment groups 13 After trabeculectomy or with prostaglandin use, higher than normal IOP = DCT GAT was found. This finding may reflect structural changes in the ocular rigidity or hemodynamics which compromise the accuracy of GAT in a magnitude similar to LASIK.

17 Accuracy and Precision with unusual corneas Many surgeries and treatments affect the biomechanical properties of the cornea and lead to an underestimation of IOP by applanation tonometry. PASCAL eliminates most false negative readings because its measurements are independent of corneal biomechanics. PASCAL is accurate and precise with LASIK or PRK 11 Lamellar and penetrating keratoplasty 12 Trabeculectomy 13 Prostaglandin therapy 14 Keratoconus 15 Corneal crosslinking therapy 16

18 25 IOP [mmhg] systolic IOP 14 Median OPA [mmhg] +50 % confidence interval OPA diastolic IOP t [sec] 0 n = 20 n = 20 n = 20 n = 20 IOP and OPA The Ocular Pulse Amplitdue OPA is the difference between systolic and diastolic IOP stemming from vascular influences. OPA in different glaucoma groups 18 Ocular Pulse amplitude is reduced in patients with NTG or POAG as compared to healthy individuals and OHT.

19 OPA An other Glaucoma Parameter PASCAL measures IOP 100 times per second, recording the dynamics of the heart rate and the ocular pulse curve. This is displayed as the Ocular Pulse Amplitude (OPA) and the full cycles can be transmitted to a PC. OPA and glaucoma: Conclusion of the study by M. Kynigopoulos Decreased OPA seems to be correlated with increased glaucomatous functional and structural damage in OAG. Assessment of OPA by DCT could therefore serve as an important additional parameter in the evaluation of glaucoma patients. 6 th World Glaucoma Consensus on Ocular blood flow 19 Dynamic Contour Tonometer and OPA Clinical Utility OPA is reduced in patients with NTG or POAG as compared to healthy individuals and OHT. In patients with glaucoma higher OPA seems to correlate with less severe glaucoma. Conversely, a small OPA is correlated with moderate to severe glaucomatous visual field loss and might be a risk factor for the development of glaucomatous visual field defects. OPA has been correlated with the resistive index in the retrobulbar vessels. I. Stalmans, R. Weinreb, A. Harris 2009

20 DTC Principle Prof. Goldmann stated, for a correct measurement of the IOP the corneal tissue must be tension free IOP induces tensions in the cornea as it pushes against the cornea, but the non-stretchable collagen matrix holds the corneal shape. 2. The cornea is tension free when the pressure is equal on both sides. (Pascal s Law) 3. When the pressure is made equal just in a small part around the center of the cornea, the center becomes radial tension free and flattens. The flattening comes from surrounding tensions pulling on the relaxed middle section. This new shape is called the DCTshape and the DCT tonometer tip is formed accordingly. 4. During a measurement a tonometer tip with the DCT shape is brought in contact with the eye. The adhesion of the tear film causes the cornea to conform to the DCT shape of the tip and frees the cornea again from its radial tensions. This allows direct measurement of the IOP as if there were no cornea.

21 How it works The PASCAL is a slit lamp mounted tonometer. Its measurement technique, which is similar to Goldmann and pneumotonometry, is relatively user independent and provides an acoustical feedback during measurement. Unlike Goldmann tonometry, the PASCAL dynamic contour tonometer (DCT) sensor tip does not applanate the cornea. Its concave shape causes a relaxation of the cornea, which helps minimize any influence on measurements that are attributed to various corneal properties. The pressure itself is acquired by a piezoresistive sensor embedded into the tonometer tip and is digitally sampled 100 times per second. An internal microprocessor analyses this direct proportional signal and extracts IOP and the ocular pulse amplitude (OPA) together with a measurement quality index (Q). These values are then displayed digitally on the PASCAL LCD screen. A measurement with good quality takes approximately six seconds. Additionally, a quick mode can be selected, to enable measurements in even a shorter period of time. The DCT principle combined with the LCD display provides IOP measurements which are relatively unaffected by various corneal properties or user bias.

22 The PASCAL DCT is certainly an improvement and great step forward within glaucoma diagnostics. Handling is amazingly simple. Dr. H. Buchholz, Bremen

23 1 Leske MC et al. Factors for glaucoma progression and the effect of treatment: EMGT; (Arch Ophthalmol Jan;121(1):48 56) 2 Chihara E. Assessment of true IOP: the gap between theory and practical data. (SurvOphthalmol 2008, May Jun, 53(3):203 18) 3 M. Sullivan Mee et al. Clinical comparison of PASCAL DCTand GAT in asymmetric open-angle glaucoma; (J Glaucoma 2007 Dec;16(8):694 9) 4 A. Böhm et al. DCT in Comparison to Intracameral IOP Measurements; (Invest Ophthalmol Vis Sci. 2008;49: ) 5 A. Kotecha et al. IOP Precision with the GAT, DCT and ORA; (Ophthalmology Apr;117(4):730 7) 6 Wang et al. Repeatability and Reproducability of GAT DCT and ORA; (J Glaucoma 2011 Jun 22) 7 Schneider E, Grehn F; Intraocular pressure measurement comparison of DCT and GAT; (J Glaucoma. 2006;15: 2 6) 8 A. Francis et al. Effects of CCT, Curvature, and IOP Level on GAT and DCT; ( /j.ophtha ) 9 Copt et al, CCT in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma; (Arch Ophthalmol Jan;117(1):14 6) 10 R. Weinreb, J. Brandt, D. Garway-Heath, F. Medeiros, 4th World Glaucoma Consensus on IOP; (Kugler Publications ISBN-10: ) 11 E. M. Kirstein et al. Evaluation of the Orssengo-Pye IOP corrective algorithm in LASIK patients with thick corneas; (Optometry 2005;76: ) 12 Papastergiou et al. Effect of recipient corneal pathology on DCT and GAT readings in eyes after PK; (Eur J Ophthalmol Jan Feb;20(1):29 34.) 13 E. Detorakis et al, Differences between Goldmann Applanation Tonometry and Dynamic Contour Tonometry following Trabeculectomy; (J of Ophthalmology doi: /2010/357387) 14 E. Detorakis et al, GAT Versus DCT in Eyes Treated With Latanoprost; (J Glaucoma 2010;19: ) 15 Read SA, Collins MJ. IOP in keratoconus. (Acta Ophthalmol 2011 Jun;89(4):358 64) 16 Gkika MG;Tonometry in keratoconic eyes before and after riboflavin/uva; corneal collagen crosslinking using three different tonometers; (Eur J Ophthalmol 2011 May 11) 17 M. Kynigopoulos et al. Decreased ocular pulse amplitude associated with functional and structural damage in open-angle glaucoma; (Eur J Ophthalmol 2012 Jan;22(1)) 18 N. Pfeiffer et al. OPA in patients with POAG, NTG, and OHT; (Br J Ophthalmol 2002;86: ) 19 R. Weinreb, A. Harris; 6th World Glaucoma Consensus on Ocular Blood Flow; (Kugler Publications ISBN-10: ) 20 H. Goldmann, Th. Schmidt; Über Applanationstonometrie; (Ophthalmologica 134, 221;1957) Disclaimer: The information contained in this brochure is for general purposes only. Ziemer Ophthalmic Systems makes no representation or warranties of any kind, expressed or implied, about the completeness, accuracy, reliability, of the content or the original studies referenced. Article No

24 The PASCAL-DCT is the first totally new concept in tonometry in over 100 years. R. Stamper, Optom Vis Sci For further information please visit our website on

Dina H. Erickson, O.D., a Denise Goodwin, O.D., a Michael Rollins, O.D., b Amber Belaustegui, O.D., c and Chad Anderson a

Dina H. Erickson, O.D., a Denise Goodwin, O.D., a Michael Rollins, O.D., b Amber Belaustegui, O.D., c and Chad Anderson a Optometry (2009) 80, 169-174 Comparison of dynamic contour tonometry and Goldmann applanation tonometry and their relationship to corneal properties, refractive error, and ocular pulse amplitude Dina H.

More information

INTRODUCTION S. HERDENER, D. HAFIZOVIC, M. PACHE, S. LAUTEBACH, J. FUNK. University Eye Hospital, Freiburg - Germany

INTRODUCTION S. HERDENER, D. HAFIZOVIC, M. PACHE, S. LAUTEBACH, J. FUNK. University Eye Hospital, Freiburg - Germany European Journal of Ophthalmology / Vol. 18 no. 1, 2008 / pp. 39-43 Is the PASCAL -Tonometer suitable for measuring intraocular pressure in clinical routine? Long- and short-term reproducibility of dynamic

More information

NIIOS. Cornea Specialist, Melles Cornea Clinic, NIIOS, Rotterdam, the Netherlands Naval Hospital, Athens, Greece VASILIS S.

NIIOS. Cornea Specialist, Melles Cornea Clinic, NIIOS, Rotterdam, the Netherlands Naval Hospital, Athens, Greece VASILIS S. Cornea Specialist, Melles Cornea Clinic, NIIOS, Rotterdam, the Netherlands Naval Hospital, Athens, Greece Goldman applanation tonometry is still the gold standard for measuring IOP, but its accuracy is

More information

MEDICAL POLICY SUBJECT: CORNEAL ULTRASOUND PACHYMETRY. POLICY NUMBER: CATEGORY: Technology Assessment

MEDICAL POLICY SUBJECT: CORNEAL ULTRASOUND PACHYMETRY. POLICY NUMBER: CATEGORY: Technology Assessment MEDICAL POLICY SUBJECT: CORNEAL ULTRASOUND,, PAGE: 1 OF: 5 If a product excludes coverage for a service, it is not covered, and medical policy criteria do not apply. If a commercial product, including

More information

Intro to Glaucoma/2006

Intro to Glaucoma/2006 Intro to Glaucoma/2006 Managing Patients with Glaucoma is Exciting Interesting Challenging But can often be frustrating! Clinical Challenges To identify patients with risk factors for possible glaucoma.

More information

Make a more confident glaucoma risk assessment with Corneal Hysteresis, a superior predictor of glaucoma progression.

Make a more confident glaucoma risk assessment with Corneal Hysteresis, a superior predictor of glaucoma progression. Make a more confident glaucoma risk assessment with Corneal Hysteresis, a superior predictor of glaucoma progression. Advancing Eye Care. American Innovation. Reichert Ocular Response Analyzer G3. Make

More information

Correlating central corneal thickness and intraocular pressure in ocular hypertension and glaucoma

Correlating central corneal thickness and intraocular pressure in ocular hypertension and glaucoma VOL. 3 NO. 1 PHILIPPINE JOURNAL OF Ophthalmology JANUARY ORIGINAL ARTICLE JUNE 07 Jonathan G. Soriano, MD 1 Ma. Margarita L. Lat-Luna, MD 1, 3 Patricia M. Khu, MD 1, 1 Department of Ophthalmology and Visual

More information

Policy #: 354 Latest Review Date: July 2011

Policy #: 354 Latest Review Date: July 2011 Name of Policy: Corneal Hysteresis Policy #: 354 Latest Review Date: July 2011 Category: Medicine Policy Grade: Active Policy but no longer scheduled for regular literature reviews and updates. Background/Definitions:

More information

Jose M. Martinez-de-la-Casa, Julian Garcia-Feijoo, Ana Fernandez-Vidal, Carmen Mendez-Hernandez, and Julian Garcia-Sanchez METHODS

Jose M. Martinez-de-la-Casa, Julian Garcia-Feijoo, Ana Fernandez-Vidal, Carmen Mendez-Hernandez, and Julian Garcia-Sanchez METHODS Ocular Response Analyzer versus Goldmann Applanation Tonometry for Intraocular Pressure Measurements Jose M. Martinez-de-la-Casa, Julian Garcia-Feijoo, Ana Fernandez-Vidal, Carmen Mendez-Hernandez, and

More information

Clinical Study Evaluation of the New Digital Goldmann Applanation Tonometer for Measuring Intraocular Pressure

Clinical Study Evaluation of the New Digital Goldmann Applanation Tonometer for Measuring Intraocular Pressure Ophthalmology, Article ID 461681, 5 pages http://dx.doi.org/1.1155/214/461681 Clinical Study Evaluation of the New Digital Goldmann Applanation Tonometer for Measuring Intraocular Pressure Yuta Sakaue,

More information

Comparison of IOP measurement by ocular response analyzer, dynamic contour, Goldmann applanation, and noncontact tonometry

Comparison of IOP measurement by ocular response analyzer, dynamic contour, Goldmann applanation, and noncontact tonometry European Journal of Ophthalmology / Vol. 19 no. 6, 2009 / pp. 936-941 Comparison of IOP measurement by ocular response analyzer, dynamic contour, Goldmann applanation, and noncontact tonometry BANU ONCEL,

More information

NON-INVASIVE OCULAR RIGIDITY MEASUREMENT: A DIFFERENTIAL TONOMETRY APPROACH

NON-INVASIVE OCULAR RIGIDITY MEASUREMENT: A DIFFERENTIAL TONOMETRY APPROACH ORIGINAL ARTICLE NON-INVASIVE OCULAR RIGIDITY MEASUREMENT: A DIFFERENTIAL TONOMETRY APPROACH Efstathios T. Detorakis 1,2, Emmanuela Tsaglioti 1, George Kymionis 1,2 Institute of Vision & Optics, University

More information

CLINICAL SCIENCES. Effect of Central Corneal Thickness, Corneal Curvature, and Axial Length on Applanation Tonometry

CLINICAL SCIENCES. Effect of Central Corneal Thickness, Corneal Curvature, and Axial Length on Applanation Tonometry CLINICAL SCIENCES Effect of Central Corneal Thickness, Corneal Curvature, and Axial Length on Applanation Tonometry Markus Kohlhaas, MD; Andreas G. Boehm, MD; Eberhard Spoerl, PhD; Antje Pürsten, Dipl-Ing

More information

Comparison of Intraocular Pressure Measurements by the Ocular Response Analyzer and Goldmann Applanation Tonometer after Penetrating Keratoplasty

Comparison of Intraocular Pressure Measurements by the Ocular Response Analyzer and Goldmann Applanation Tonometer after Penetrating Keratoplasty Comparison of Intraocular Pressure Measurements by the Ocular Response Analyzer and Goldmann Applanation Tonometer after Penetrating Keratoplasty in Keratoconic Patients Sepehr Feizi, MD 1 Mohammad Pakravan,

More information

Peretyagin O.A., Cand. Med. Sc., Ass. Prof.; Dmitriev S.K., Dr. Med. Sc., Prof.; Lazar Yu.M., Cand. Med. Sc.; Tatarina Yu.A., Junior Research Fellow

Peretyagin O.A., Cand. Med. Sc., Ass. Prof.; Dmitriev S.K., Dr. Med. Sc., Prof.; Lazar Yu.M., Cand. Med. Sc.; Tatarina Yu.A., Junior Research Fellow Changes in corneoscleral rigidity and corneal thickness at various target intraocular pressures in patients with stabilized primary open-angle glaucoma Peretyagin O.A., Cand. Med. Sc., Ass. Prof.; Dmitriev

More information

CORNEAL HYSTERESIS AND INTRAOCULAR PRESSURE MEASUREMENT

CORNEAL HYSTERESIS AND INTRAOCULAR PRESSURE MEASUREMENT CORNEAL HYSTERESIS AND INTRAOCULAR PRESSURE MEASUREMENT Protocol: OPT018 Effective Date: August 1, 2017 Table of Contents Page COMMERCIAL, MEDICARE & MEDICAID COVERAGE RATIONALE... 1 DESCRIPTION OF SERVICES...

More information

Central corneal thickness determined with optical coherence tomography in various types of glaucoma

Central corneal thickness determined with optical coherence tomography in various types of glaucoma Br J Ophthalmol 2000;84:1233 1237 1233 Department of Ophthalmology, Ludwig-Maximilians- University, Munich, Germany M Bechmann M J Thiel B Roesen S Ullrich M W Ulbig K Ludwig Correspondence to: Martin

More information

Central corneal thickness and vascular risk factors in normal tension glaucoma

Central corneal thickness and vascular risk factors in normal tension glaucoma Central corneal thickness and vascular risk factors in normal tension glaucoma Aoife Doyle, Ahmed Bensaid and Yves Lachkar L Institut du Glaucome, Fondation Hoˆpital St. Joseph, Paris, France ABSTRACT.

More information

Role of central corneal thickness measurement in management of open angle glaucoma and glaucoma suspects in Calabar, Nigeria

Role of central corneal thickness measurement in management of open angle glaucoma and glaucoma suspects in Calabar, Nigeria Original Research Article Role of central corneal thickness measurement in management of open angle glaucoma and glaucoma suspects in Calabar, Nigeria Nkanga DG 1,2, Ibanga AA 1,2, Nkanga ED 2, Etim BA

More information

Deep anterior lamellar keratoplasty (DALK) is considered

Deep anterior lamellar keratoplasty (DALK) is considered Cornea Comparison of the Ocular Response Analyzer and the Goldmann Applanation Tonometer for Measuring Intraocular Pressure after Deep Anterior Lamellar Keratoplasty Sepehr Feizi, 1,2 Ali Hashemloo, 1,2

More information

Goldmann Tonometer Prism with an Optimized Error Correcting Applanation Surface

Goldmann Tonometer Prism with an Optimized Error Correcting Applanation Surface Goldmann Tonometer Prism with an Optimized Error Correcting Applanation Surface Item Type Article Authors McCafferty, Sean; Lim, Garrett; Duncan, William; Enikov, Eniko; Schwiegerling, Jim Citation Goldmann

More information

An Ultra-High-Speed Scheimpflug Camera for Evaluation of Corneal Deformation Response and Its Impact on IOP Measurement

An Ultra-High-Speed Scheimpflug Camera for Evaluation of Corneal Deformation Response and Its Impact on IOP Measurement Glaucoma An Ultra-High-Speed Scheimpflug Camera for Evaluation of Corneal Deformation Response and Its Impact on IOP Measurement Christopher Kai-Shun Leung, 1 Cong Ye, 1 and Robert N. Weinreb 2 1 Department

More information

CORNEAL HYSTERESIS AND INTRAOCULAR PRESSURE MEASUREMENT

CORNEAL HYSTERESIS AND INTRAOCULAR PRESSURE MEASUREMENT CORNEAL HYSTERESIS AND INTRAOCULAR PRESSURE MEASUREMENT UnitedHealthcare Oxford Clinical Policy Policy Number: DIAGNOSTIC 048.12 T2 Effective Date: July 1, 2017 Table of Contents Page INSTRUCTIONS FOR

More information

Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer

Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer 518 EXTENDED REPORT Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer P Gunvant, M Baskaran, L Vijaya, I S Joseph, R J Watkins,

More information

CLINICAL SCIENCES. Clinical Significance of Central Corneal Thickness in the Management of Glaucoma

CLINICAL SCIENCES. Clinical Significance of Central Corneal Thickness in the Management of Glaucoma CLINICAL SCIENCES Clinical Significance of Central Corneal Thickness in the Management of Glaucoma Carolyn Y. Shih, MD; Joshua S. Graff Zivin, PhD; Stephen L. Trokel, MD; James C. Tsai, MD Objective: To

More information

The Heritability of Corneal Hysteresis and Ocular Pulse Amplitude: A Twin Study

The Heritability of Corneal Hysteresis and Ocular Pulse Amplitude: A Twin Study The Heritability of Corneal Hysteresis and Ocular Pulse Amplitude: A Twin Study Francis Carbonaro 1, Toby Andrew 2, David A Mackey 3, Tim D Spector 1, Chris J Hammond 1,4 1. Twin Research and Genetic Epidemiology

More information

December 2016, Volume: 8, Issue: 12, Pages: , DOI:

December 2016, Volume: 8, Issue: 12, Pages: , DOI: Electronic Physician (ISSN: 2008-5842) http://www.ephysician.ir December 2016, Volume: 8, Issue: 12, Pages: 3429-3433, DOI: http://dx.doi.org/10.19082/3429 Refinement of Intraocular Pressure Measurements

More information

Analysis of differences in intraocular pressure evaluation performed with contact and non-contact devices

Analysis of differences in intraocular pressure evaluation performed with contact and non-contact devices Lanza et al. BMC Ophthalmology (2018) 18:233 https://doi.org/10.1186/s12886-018-0900-5 RESEARCH ARTICLE Open Access Analysis of differences in intraocular pressure evaluation performed with contact and

More information

Evaluation of the Effect of Diabetes Mellitus on Corneal Biomechanics

Evaluation of the Effect of Diabetes Mellitus on Corneal Biomechanics The Egyptian Journal of Hospital Medicine (January 2019) Vol. 74 (4), Page 782-788 Abd Elmagid Mohamed Tag Eldin, Abdulmoez Haddad Ahmed, Amr Khalil Abdelmonem* Ophthalmology department, Faculty of Medicine,

More information

1 Birmingham and Midland Eye Centre, City Hospital, Birmingham, 2 Ophthalmic Research Group, Life and Health Sciences, Aston

1 Birmingham and Midland Eye Centre, City Hospital, Birmingham, 2 Ophthalmic Research Group, Life and Health Sciences, Aston Accuracy of Goldmann, Ocular Response Analyser, Pascal and TonoPen XL Tonometry in Keratoconic and Normal Eyes Susan P Mollan MB CHB MRCOphth 1, James S Wolffsohn BSc PhD PgDip MCOptom 2, Maged Nessim

More information

GLAUCOMA REPEAT READINGS PATHWAY

GLAUCOMA REPEAT READINGS PATHWAY GLAUCOMA REPEAT READINGS PATHWAY Level 1a: Goldmann style applanation tonometry repeat readings A first level community service for IOP refinement where other signs of glaucoma are not present will reduce

More information

4/06/2013. Medication Observation POAG. Proportion. Native American 0.1% 0.4%

4/06/2013. Medication Observation POAG. Proportion. Native American 0.1% 0.4% Clinical Research in Glaucoma: Putting Science into Practice J. James Thimons, O.D., FAAO Chairman, National Glaucoma Society www.nationalglaucomasociety.org Ocular Hypertension Treatment Study (OHTS)

More information

LOCSU Community Services. Glaucoma Repeat Readings & OHT Monitoring Community Service Pathway. Issued by Local Optical Committee Support Unit May 2009

LOCSU Community Services. Glaucoma Repeat Readings & OHT Monitoring Community Service Pathway. Issued by Local Optical Committee Support Unit May 2009 LOCSU Community Services Glaucoma Repeat Readings & OHT Monitoring Community Service Pathway Issued by Local Optical Committee Support Unit May 2009 [Revised May 2016, Version 3.3] Contents Page Executive

More information

Comparison of Goldmann applanation tonometry and dynamic contour tonometry in healthy and glaucomatous eyes

Comparison of Goldmann applanation tonometry and dynamic contour tonometry in healthy and glaucomatous eyes (2009) 23, 262 269 & 2009 Macmillan Publishers Limited All rights reserved 0950-222X/09 $32.00 www.nature.com/eye CLINICAL STUDY Comparison of Goldmann applanation tonometry and dynamic contour tonometry

More information

Central Corneal Thickness (CCT) among Glaucoma and Non Glaucoma Patients in a Hospital Based Population

Central Corneal Thickness (CCT) among Glaucoma and Non Glaucoma Patients in a Hospital Based Population ISSN 2278 0211 (Online) Central Corneal Thickness (CCT) among Glaucoma and Non Glaucoma Patients in a Hospital Based Population Dr. Sheldon James Goudinho Professor, Department of Ophthalmology, Dr. Somervell

More information

The innovative aspects are that ORA G3 is currently the only device capable of measuring corneal hysteresis.

The innovative aspects are that ORA G3 is currently the only device capable of measuring corneal hysteresis. pat hways ORA G3 to measure corneal hysteresis Medtech innovation briefing Published: 18 June 2018 nice.org.uk/guidance/mib150 Summary The technology described in this briefing is Ocular Response Analyzer

More information

Role of Central Corneal Thickness in Circadian Intraocular Pressure Fluctuations among Patients with Primary Open Angle Glaucoma

Role of Central Corneal Thickness in Circadian Intraocular Pressure Fluctuations among Patients with Primary Open Angle Glaucoma Role of Central Corneal Thickness in Circadian Intraocular Pressure Fluctuations among Patients with Primary Open Angle Glaucoma Mohannad Albdour MD*, Karanjit Kooner MD, PHD** ABSTRACT Objectives: To

More information

Comparison of a New Non-Contact Tonometer with Goldmann Applanation

Comparison of a New Non-Contact Tonometer with Goldmann Applanation Eye (1989) 3, 332-337 Comparison of a New Non-Contact Tonometer with Goldmann Applanation M. J. MOSELEY, N. M. EVANS and A. R. FIELDER Leicester Summary A comparison of a new non-contact tonometer (Keeler

More information

Intraocular pressure (IOP) is of fundamental importance in

Intraocular pressure (IOP) is of fundamental importance in Glaucoma Effect of Corneal Stiffening on Goldmann Applanation Tonometry and Tono-Pen Measurements in Canine Eyes Junhua Tang, 1 Xueliang Pan, 2 Paul A. Weber, 3 and Jun Liu 1,3 PURPOSE. To experimentally

More information

CLINICAL SCIENCES. Comparison of Ocular Response Analyzer Parameters in Chinese Subjects With Primary Angle-Closure and Primary Open-Angle Glaucoma

CLINICAL SCIENCES. Comparison of Ocular Response Analyzer Parameters in Chinese Subjects With Primary Angle-Closure and Primary Open-Angle Glaucoma CLINICAL SCIENCES Comparison of Ocular Response Analyzer Parameters in Chinese Subjects With Primary Angle-Closure and Primary Open-Angle Glaucoma Arun Narayanaswamy, DNB; Daniel H. Su, FRCS(Edin); Mani

More information

Central corneal thickness among glaucoma patients attending Menelik II Hospital, Addis Ababa, Ethiopia

Central corneal thickness among glaucoma patients attending Menelik II Hospital, Addis Ababa, Ethiopia Original article Central corneal thickness among glaucoma patients attending Menelik II Hospital, Addis Ababa, Ethiopia Zelalem Gizachew 1, Abiy Mulugeta 1* Abstract Background: Glaucoma is one of the

More information

Clinical Profile of Primary Open Angle Glaucoma Suspects.

Clinical Profile of Primary Open Angle Glaucoma Suspects. DOI: 10.21276/aimdr.2018.4.2.OT3 Original Article ISSN (O):2395-2822; ISSN (P):2395-2814 Clinical Profile of Primary Open Angle Glaucoma Suspects. Pradnya Abhinav Mohan 1 1 Fellow Phaco-surgery, Department

More information

Present relevant clinical findings of four landmark glaucoma trials OHTS, EMGT, CNTGS and CIGTS.

Present relevant clinical findings of four landmark glaucoma trials OHTS, EMGT, CNTGS and CIGTS. Course title: The Glaucoma Compass Course length: 1 hour +/- 31 slides Corse Description: Even with the technology and available information, glaucoma decision making can still be confusing. How should

More information

The Egyptian Journal of Hospital Medicine (January 2018) Vol. 70 (8), Page

The Egyptian Journal of Hospital Medicine (January 2018) Vol. 70 (8), Page The Egyptian Journal of Hospital Medicine (January 2018) Vol. 70 (8), Page 1371-1376 Relationship Between Corneal Astigmatism and Intraocular Pressure Abdulrahman E. Algarni 1, Mohammad Abahussin 2, Nuha

More information

The Role of the RNFL in the Diagnosis of Glaucoma

The Role of the RNFL in the Diagnosis of Glaucoma Chapter 1. The Role of the RNFL in the Diagnosis of Glaucoma Introduction Glaucoma is an optic neuropathy characterized by a loss of of retinal ganglion cells and their axons, the Retinal Nerve Fiber Layer

More information

Intraocular pressure (IOP) is one of the most critical risk factors

Intraocular pressure (IOP) is one of the most critical risk factors PERSPECTIVE Brenda Nuyen, MD* and Kaweh Mansouri, MD, MPHÞþ Abstract: According to the World Health Organization, glaucoma is the leading cause of irreversible blindness worldwide. Although intraocular

More information

Elevated intraocular pressure (IOP) is the most important. The Effect of Trabeculectomy on Ocular Pulse Amplitude. Glaucoma

Elevated intraocular pressure (IOP) is the most important. The Effect of Trabeculectomy on Ocular Pulse Amplitude. Glaucoma Glaucoma The Effect of Trabeculectomy on Ocular Pulse Amplitude Christophe Breusegem, 1 Steffen Fieuws, 2 Thierry Zeyen, 1 and Ingeborg Stalmans 1 PURPOSE. To investigate whether trabeculectomy, besides

More information

Goldmann applanation tonometry error relative to true intracameral intraocular pressure in vitro and in vivo

Goldmann applanation tonometry error relative to true intracameral intraocular pressure in vitro and in vivo McCafferty et al. BMC Ophthalmology (2017) 17:215 DOI 10.1186/s12886-017-0608-y RESEARCH ARTICLE Goldmann applanation tonometry error relative to true intracameral intraocular pressure in vitro and in

More information

Corneal Hysteresis and Visual Field Asymmetry in Open Angle Glaucoma SUBJECTS AND METHODS

Corneal Hysteresis and Visual Field Asymmetry in Open Angle Glaucoma SUBJECTS AND METHODS Glaucoma Corneal Hysteresis and Visual Field Asymmetry in Open Angle Glaucoma Aashish Anand, 1 Carlos Gustavo V. De Moraes, 1,2 Christopher C. Teng, 1,2,3 Celso Tello, 1,3 Jeffrey M. Liebmann, 1,2 and

More information

The changes in corneal biomechanical parameters after phototherapeutic keratectomy in eyes with granular corneal dystrophy

The changes in corneal biomechanical parameters after phototherapeutic keratectomy in eyes with granular corneal dystrophy (2009) 23, 1790 179 & 2009 Macmillan Publishers Limited All rights reserved 090-222X/09 $32.00 www.nature.com/eye CLINICAL STUDY The changes in corneal biomechanical parameters after phototherapeutic keratectomy

More information

Prevalence Of Primary Open Angle Glaucoma in Diabetic Patients

Prevalence Of Primary Open Angle Glaucoma in Diabetic Patients IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861.Volume 16, Issue 6 Ver. III (June. 2017), PP 147-151 www.iosrjournals.org Prevalence Of Primary Open Angle Glaucoma

More information

Glaucoma. Glaucoma. Optic Disc Cupping

Glaucoma. Glaucoma. Optic Disc Cupping Glaucoma What is Glaucoma? Bruce James A group of diseases in which damage to the optic nerve occurs as a result of intraocualar pressure being above the physiological norm for that eye Stoke Mandeville

More information

Ever since the recognition that certain forms of blindness. Central corneal thickness, tonometry, and glaucoma risk a guide for the perplexed

Ever since the recognition that certain forms of blindness. Central corneal thickness, tonometry, and glaucoma risk a guide for the perplexed CJO LECTURE 2007 Central corneal thickness, tonometry, and glaucoma risk a guide for the perplexed James D. Brandt, MD ABSTRACT RÉSUMÉ The results of the Ocular Hypertension Treatment Study (OHTS) brought

More information

Correspondence should be addressed to Fusako Fujimura;

Correspondence should be addressed to Fusako Fujimura; BioMed Research International Volume 2013, Article ID 370592, 5 pages http://dx.doi.org/10.1155/2013/370592 Research Article Repeatability and Reproducibility of Measurements Using a NT-530P Noncontact

More information

Using Biomechanics to Advance Glaucoma Care

Using Biomechanics to Advance Glaucoma Care 1 FEBRUARY 2012 Using Biomechanics to Advance Glaucoma Care A panel of experts discusses how affordable new technology expands screening, diagnosis and monitoring of glaucoma. Sponsored by Ben Gaddie,

More information

Medical Management of Glaucoma

Medical Management of Glaucoma Medical Management of Glaucoma Medical Management of Glaucoma Keith Barton Consultant Ophthalmologist Moorfields Eye Hospital Foundation Trust Honorary Reader Department of Epidemiology and Genetics Institute

More information

Comparison of icare Tonometer with Pulsair and Tonopen in Domiciliary Work

Comparison of icare Tonometer with Pulsair and Tonopen in Domiciliary Work Optometry in Practice Vol 6 (2005) 33 39 Comparison of icare Tonometer with Pulsair and Tonopen in Domiciliary Work Dawn E C Roberts BSc(Hons) MSc MCOptom Healthcall Optical Services, Luton, Bedfordshire,

More information

LOCSU Community Services. Glaucoma Repeat Readings & OHT Monitoring Community Service Pathway. Issued by Local Optical Committee Support Unit May 2009

LOCSU Community Services. Glaucoma Repeat Readings & OHT Monitoring Community Service Pathway. Issued by Local Optical Committee Support Unit May 2009 LOCSU Community Services Glaucoma Repeat Readings & OHT Monitoring Community Service Pathway Issued by Local Optical Committee Support Unit May 2009 [Revised November 2013] Contents Page Executive Summary...

More information

Glaucoma is the most frequent

Glaucoma is the most frequent Refined glaucoma referral practice offers prospect of improved capacity and expanded role for primary eye care professionals BY ROD MCNEIL Glaucoma is the most frequent cause of irreversible blindness

More information

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma Med. J. Cairo Univ., Vol. 83, No. 2, September: 67-72, 2015 www.medicaljournalofcairouniversity.net Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

More information

Glaucoma is the leading cause of irreversible blindness in

Glaucoma is the leading cause of irreversible blindness in CLINICAL SCIENCE Determinants of Postoperative Corneal Edema and Impact on Goldmann Intraocular Pressure Yuqiang Huang, MBBS,* Mingzhi Zhang, MD,* Chukai Huang, MBBS,* Bin Chen, PhD,* Dennis S. C. Lam,

More information

Collaboration in the care of glaucoma patients and glaucoma suspects. Barry Emara MD FRCS(C) Nico Ristorante November 29, 2012

Collaboration in the care of glaucoma patients and glaucoma suspects. Barry Emara MD FRCS(C) Nico Ristorante November 29, 2012 Collaboration in the care of glaucoma patients and glaucoma suspects Barry Emara MD FRCS(C) Nico Ristorante November 29, 2012 Goals of Collaboration Patient-centred and evidence based approach Timely access

More information

3/23/2016. Regina Smolyak, MD Glaucoma Service Flaum Eye Institute

3/23/2016. Regina Smolyak, MD Glaucoma Service Flaum Eye Institute Under the Affordable Care Act providers are pressured to maintain a high level of medical care, while reducing the cost of the treatment delivered Regina Smolyak, MD Glaucoma Service Flaum Eye Institute

More information

PRESCRIBING IN GLAUCOMA: GUIDELINES FOR NZ OPTOMETRISTS

PRESCRIBING IN GLAUCOMA: GUIDELINES FOR NZ OPTOMETRISTS PRESCRIBING IN GLAUCOMA: GUIDELINES FOR NZ OPTOMETRISTS Introduction Independent prescribing relates to the capacity to use clinical judgement in respect of diagnosis and treatment. It does not mean working

More information

Fluctuation of Intraocular Pressure and Glaucoma Progression in the Early Manifest Glaucoma Trial

Fluctuation of Intraocular Pressure and Glaucoma Progression in the Early Manifest Glaucoma Trial Fluctuation of Intraocular Pressure and Glaucoma Progression in the Early Manifest Glaucoma Trial Boel Bengtsson, PhD, 1 M. Cristina Leske, MD, MPH, 2 Leslie Hyman, PhD, 2 Anders Heijl, MD, PhD, 1 Early

More information

Spontaneous Intraocular Pressure Reduction in Normal-Tension Glaucoma and Associated Clinical Factors

Spontaneous Intraocular Pressure Reduction in Normal-Tension Glaucoma and Associated Clinical Factors CLINICAL INVESTIGATIONS Spontaneous Intraocular Pressure Reduction in Normal-Tension Glaucoma and Associated Clinical Factors Akihiro Oguri, Tetsuya Yamamoto and Yoshiaki Kitazawa Department of Ophthalmology,

More information

This policy is applicable to Commercial Products only. For BlueCHiP for Medicare, see related policy section.

This policy is applicable to Commercial Products only. For BlueCHiP for Medicare, see related policy section. Medical Coverage Policy Ophthalmologic Techniques that Evaluate the Posterior Segment for Glaucoma EFFECTIVE DATE: 01 01 2017 POLICY LAST UPDATED: 09 18 2018 OVERVIEW Several techniques have been developed

More information

THE TAMILNADU DR.M.G.R. MEDICAL UNIVERSITY CHENNAI, TAMILNADU

THE TAMILNADU DR.M.G.R. MEDICAL UNIVERSITY CHENNAI, TAMILNADU A STUDY ON COMPARISON OF CENTRAL CORNEAL THICKNESS IN NORMALS, PRIMARY OPEN ANGLE GLAUCOMA AND OCULAR HYPERTENSIVES DISSERTATION SUBMITTED FOR MASTER OF SURGERY DEGREE BRANCH III - OPHTHALMOLOGY APRIL

More information

In Practice. Surgical Procedures Diagnosis New Drugs

In Practice. Surgical Procedures Diagnosis New Drugs In Practice Surgical Procedures Diagnosis New Drugs 32 35 Bowman + Bulk = Better Results Mid-stromal lamellar keratoplasty (MSLK) offers a new approach to the management of advanced keratoconus that can

More information

AR CS205 Clinical Pilot Study Topline Results

AR CS205 Clinical Pilot Study Topline Results AR-13324-CS205 Clinical Pilot Study Topline Results 1 Important Information The information in this presentation is current only as of its date and may have changed or may change in the future. We undertake

More information

Correlation between presence of primary irisand cilliary body cysts and intraocular pressure

Correlation between presence of primary irisand cilliary body cysts and intraocular pressure European Review for Medical and Pharmacological Sciences 2017; 21: 3985-3989 Correlation between presence of primary irisand cilliary body cysts and intraocular pressure R. ZHU, L. CHENG, D.-M. WANG Institute

More information

Central Cornea Thickness in Glaucoma and Non- Glaucoma African Population

Central Cornea Thickness in Glaucoma and Non- Glaucoma African Population Ophthalmology Research: An International Journal 6(4): 1-8, 2016; Article no.or.31121 ISSN: 2321-7227 SCIENCEDOMAIN international www.sciencedomain.org Central Cornea Thickness in Glaucoma and Non- Glaucoma

More information

Clinical Study Differences between Goldmann Applanation Tonometry and Dynamic Contour Tonometry following Trabeculectomy

Clinical Study Differences between Goldmann Applanation Tonometry and Dynamic Contour Tonometry following Trabeculectomy Ophthalmology Volume 2010, Article ID 357387, 5 pages doi:10.1155/2010/357387 Clinical Study Differences between Goldmann Applanation Tonometry and Dynamic Contour Tonometry following Trabeculectomy Efstathios

More information

Glaucoma: Diagnostic Modalities

Glaucoma: Diagnostic Modalities Glaucoma: Diagnostic Modalities - Dr. Barun Kumar Nayak, Dr. Sarika Ramugade Glaucoma is a leading cause of blindness in the world, especially in older people. Early detection and treatment by ophthalmologist

More information

Goldmann applanation tonometry compared with corneal-compensated intraocular pressure in the evaluation of primary open-angle Glaucoma

Goldmann applanation tonometry compared with corneal-compensated intraocular pressure in the evaluation of primary open-angle Glaucoma Ehrlich et al. BMC Ophthalmology 2012, 12:52 RESEARCH ARTICLE Open Access Goldmann applanation tonometry compared with corneal-compensated intraocular pressure in the evaluation of primary open-angle Glaucoma

More information

Corneal hysteresis in patients with glaucoma-like optic discs, ocular hypertension and glaucoma

Corneal hysteresis in patients with glaucoma-like optic discs, ocular hypertension and glaucoma Murphy et al. BMC Ophthalmology (2017) 17:1 DOI 10.1186/s12886-016-0396-9 RESEARCH ARTICLE Open Access Corneal hysteresis in patients with glaucoma-like optic discs, ocular hypertension and glaucoma Melissa

More information

pat hways Medtech innovation briefing Published: 15 March 2016 nice.org.uk/guidance/mib57

pat hways Medtech innovation briefing Published: 15 March 2016 nice.org.uk/guidance/mib57 pat hways Icare rebound tonometer to measure intraocular pressure Medtech innovation briefing Published: 15 March 2016 nice.org.uk/guidance/mib57 Summary Icare products are the only devices that currently

More information

City, University of London Institutional Repository

City, University of London Institutional Repository City Research Online City, University of London Institutional Repository Citation: Dabasia, P. L., Lawrenson, J. & Murdoch, I. E. (2015). Evaluation of a new rebound tonometer for self-measurement of intraocular

More information

Kathryn L. Wotman, DVM, DACVIM Jeffrey E. Bowersox, DVM, DACVO. Veterinary Specialty Center of Delaware

Kathryn L. Wotman, DVM, DACVIM Jeffrey E. Bowersox, DVM, DACVO. Veterinary Specialty Center of Delaware Kathryn L. Wotman, DVM, DACVIM Jeffrey E. Bowersox, DVM, DACVO Veterinary Specialty Center of Delaware Contact Lensesuse in Veterinary Ophthalmology -Corneal erosions Spontaneous Chronic Corneal Epithelial

More information

Effect of brimonidine on intraocular pressure in normal tension glaucoma: A short term clinical trial

Effect of brimonidine on intraocular pressure in normal tension glaucoma: A short term clinical trial European Journal of Ophthalmology / Vol. 13 no. 7, 2003 / pp. 611-615 Effect of brimonidine on intraocular pressure in normal tension glaucoma: A short term clinical trial S.A. GANDOLFI, L. CIMINO, P.

More information

Intraocular Pressure Measurements Referring to the Corneal Thickness in Keratoconic Eyes After Corneal Crosslinking with Riboflavin and Ultraviolet A

Intraocular Pressure Measurements Referring to the Corneal Thickness in Keratoconic Eyes After Corneal Crosslinking with Riboflavin and Ultraviolet A ORIGINAL PAPER doi: 10.5455/medarh.2015.69.334-338 Med Arh. 2015 Oct; 69(5): 334-338 Received: August 25th 2015 Accepted: October 05th 2015 2015 Sanja Sefic Kasumovic, Milka Mavija, Aida Kasumovic, Orhan

More information

Central Corneal Thickness-An important variable for prognostication in Primary Open Angle glaucoma; A Kolkata based study in Eastern India

Central Corneal Thickness-An important variable for prognostication in Primary Open Angle glaucoma; A Kolkata based study in Eastern India Original article: Central Corneal Thickness-An important variable for prognostication in Primary Open Angle glaucoma; A Kolkata based study in Eastern India 1Dr. Apala Bhattacharya, 2 Dr Gautam Bhaduri,

More information

1/31/2018. Course Objectives. Diagnostic Testing. Optic Nerve Damage ANATOMY AND PHYSIOLOGY OF A GLAUCOMA WORK-UP/TONOMETRY TECHNICIAN: -SDP

1/31/2018. Course Objectives. Diagnostic Testing. Optic Nerve Damage ANATOMY AND PHYSIOLOGY OF A GLAUCOMA WORK-UP/TONOMETRY TECHNICIAN: -SDP ANATOMY AND PHYSIOLOGY OF A GLAUCOMA WORK-UP/TONOMETRY KNOW THE DISEASE PROCESS TECHNICIAN: EXPLAIN PROCESS OF EXAMINATION Presenters: Dana McMahan, COA Nicole Smith, COA Engage with patient s, help alleviate

More information

The Ocular Response Analyzer (ORA; Reichert Ophthalmic

The Ocular Response Analyzer (ORA; Reichert Ophthalmic Glaucoma Lack of Association Between Corneal Hysteresis and Corneal Resistance Factor With Glaucoma Severity in Primary Angle Closure Glaucoma Monisha E. Nongpiur, 1,2 Owen Png, 2 Jestin W. Chiew, 3 Kenric

More information

Targeting Intraocular Pressure in Glaucoma: a Teaching Case Report 1

Targeting Intraocular Pressure in Glaucoma: a Teaching Case Report 1 Targeting Intraocular Pressure in Glaucoma: a Teaching Case Report 1 By: Andrew Kemp, OD, Marcus Gonzales, OD, FAAO, Joe DeLoach, OD, FAAO, and Zanna Kruoch, OD FAAO Background Glaucoma is a range of conditions

More information

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists 3,700 108,500 1.7 M Open access books available International authors and editors Downloads Our

More information

Comparison of Central Corneal Thickness Measurements with Pentacam, Orbscan II, and Ultrasound Pachymeter

Comparison of Central Corneal Thickness Measurements with Pentacam, Orbscan II, and Ultrasound Pachymeter Comparison of Central Corneal Thickness Measurements with Pentacam, Orbscan II, and Ultrasound Pachymeter Abbas-Ali Yekta, PhD 1 Hassan Hashemi, MD 2,3 Mehdi KhabazKhoob, MSc 3 Asghar Dostdar, MSc 4 Shiva

More information

24-hour IOP fluctuation: myth or reality?

24-hour IOP fluctuation: myth or reality? Journal for Modeling in Ophthalmology 2016; 2:103-109 Review article 24-hour IOP fluctuation: myth or reality? Luciano Quaranta 1, Ivano Riva 1, Francesco Oddone 2 1 Department of Medical and Surgical

More information

Kobe University Repository : Kernel

Kobe University Repository : Kernel Kobe University Repository : Kernel タイトル Title 著者 Author(s) 掲載誌 巻号 ページ Citation 刊行日 Issue date 資源タイプ Resource Type 版区分 Resource Version 権利 Rights DOI JaLCDOI URL Agreement of Rebound Tonometer in Measuring

More information

The Association of Central corneal thickness with Intra-ocular Pressure and Refractive Error in a Nigerian Population

The Association of Central corneal thickness with Intra-ocular Pressure and Refractive Error in a Nigerian Population Peer Reviewed, Open Access, Free Published Quarterly Mangalore, South India ISSN 0972-5997 Volume 6, Issue 3; Jul-Sep 2007 Original Article The Association of Central corneal thickness with Intra-ocular

More information

Comparison between Pascal dynamic contour tonometer and Goldmann applanation tonometer after different types of refractive surgery

Comparison between Pascal dynamic contour tonometer and Goldmann applanation tonometer after different types of refractive surgery DOI 10.1007/s00417-010-1431-9 REFRACTIVE SURGERY Comparison between Pascal dynamic contour tonometer and Goldmann applanation tonometer after different types of refractive surgery Antonios P. Aristeidou

More information

Effects of Intracorneal Ring Segment on Corneal Biomechanics in Keratoconic Eyes. Abstract

Effects of Intracorneal Ring Segment on Corneal Biomechanics in Keratoconic Eyes. Abstract Effects of Intracorneal Ring Segment on Corneal Biomechanics in Keratoconic Eyes Javad Amoozadeh, MD 1 Nima Mirzaee Rad, MD 2 Amir Houshang Beheshtnejad, MD 3 Ahmad Kheirkhah, MD 1 Hassan Hashemi, MD 4,5

More information

Modalities of Tonometry and their Accuracy with Respect to Corneal Thickness and Irregularities

Modalities of Tonometry and their Accuracy with Respect to Corneal Thickness and Irregularities REVIEW J Optom 2008;1:43-49 Modalities of Tonometry and their Accuracy with Respect to Corneal Thickness and Irregularities Carlos Gustavo V. De Moraes 1, Tiago S. Prata 1, Jeffrey Liebmann 2,3 and Robert

More information

IOP in Perspective. IOP in Perspective

IOP in Perspective. IOP in Perspective IOP in Perspective Commercial Interest Disclosures Nature of Relevant Financial Relationship (Why are we so hung up on IOP?) Leo Semes, OD, FAAO Maculogix Honorarium Speaker Science Based Health Honorarium

More information

Original Article Effects of topical travoprost 0.004% on intraocular pressure and corneal biomechanical properties in an animal model

Original Article Effects of topical travoprost 0.004% on intraocular pressure and corneal biomechanical properties in an animal model Original Article Effects of topical travoprost 0.004% on intraocular pressure and corneal biomechanical properties in an animal model Gabriel Lazcano-Gomez, MD, a David Ancona-Lezama, MD, b Felix Gil-Carrasco,

More information

Long Term Efficacy of Repeat Treatment with SLT: Seven Years Follow up

Long Term Efficacy of Repeat Treatment with SLT: Seven Years Follow up Long Term Efficacy of Repeat Treatment with SLT: Seven Years Follow up Lawrence F. Jindra, MD Columbia University Winthrop University Hospital Disclosure Speaker has independently conducted and financed

More information

CLINICAL SCIENCES. tonometry (GAT) has become the gold standard against which other tonometers

CLINICAL SCIENCES. tonometry (GAT) has become the gold standard against which other tonometers CLINICAL SCIENCES Dynamic Contour Tonometry A Comparative Study on Human Cadaver Eyes Christoph Kniestedt, MD; Michelle Nee, MD; Robert L. Stamper, MD Objective: To compare intraocular pressure measurements

More information

Aerie Pharmaceuticals, Inc. Additional Rhopressa Rocket 1 Analyses and Path Forward

Aerie Pharmaceuticals, Inc. Additional Rhopressa Rocket 1 Analyses and Path Forward Aerie Pharmaceuticals, Inc. Additional Rhopressa Rocket 1 Analyses and Path Forward May 7, 2015 1 Important Information Any discussion of the potential use or expected success of our product candidates

More information

Is NTG different from POAG?

Is NTG different from POAG? Is NTG different from POAG? Sunita Radhakrishnan, M.D Glaucoma Center of San Francisco Glaucoma Research and Education Group Subset of POAG 1 Connective tissue structure within ONH Ganglion cell susceptibility

More information