Performance Evaluation of 200 and 400 mm PARTI MAG II, Bailey Fischer & Porter Electromagnetic Flowmeters, Installed in Partially Filled Pipes

Size: px
Start display at page:

Download "Performance Evaluation of 200 and 400 mm PARTI MAG II, Bailey Fischer & Porter Electromagnetic Flowmeters, Installed in Partially Filled Pipes"

Transcription

1 Performance Evaluation of 200 and 400 mm PARTI MAG II, Bailey Fischer & Porter Electromagnetic Flowmeters, Installed in Partially Filled Pipes A Report for NMSPU Department of Trade and Industry 151 Buckingham Palace Road London, SW1W 9SS Project No: WSDC54 Report No: 195/99 Date: 13 April 1999

2 Flow Centre National Engineering Laboratory East Kilbride, Glasgow, G75 0QU Tel: Fax: Performance Evaluation of 200 and 400 mm, PARTI MAG II, Bailey Fischer & Porter Electromagnetic Flowmeters, Installed in Partially Filled Pipes A Report for NSMPU Department of Trade and Industry 151 Buckingham Palace Road London, SW1W 9SS Prepared by: Mr W C Brunton... Approved by: Mr J Williamson... Date: 13 April 1999 for Dr F C Kinghorn General Manager Report No: 195/99 Page 1 of?

3 C O N T E N T S Page EXECUTIVE SUMMARY INTRODUCTION DETAILS OF THE ELECTROMAGNETIC FLOWMETERS mm NB Flowmeter mm NB Flowmeter METHOD OF TEST mm NB Flowmeter mm NB Flowmeter UNCERTAINTY RESULTS mm NB Flowmeter mm NB Flowmeter... 5 APPENDIX: MANUFACTURER S SPECIFICATION FOR BAILEY FISCHER & PORTER, PART MAG II, ELECTROMAGNETIC FLOWMETERS FOR PART FILLED AND FULLY CHARGED PIPE FLOWS... Report No: 195/99 Page 2 of?

4 EXECUTIVE SUMMARY One 200 and one 400 mm nominal bore PARTI MAG II, electromagnetic flowmeter, designed for measuring flowrates in partially filled pipes and manufactured by Bailey Fischer & Porter were calibrated in the large water flow facility at NEL. The 200 mm flowmeter was first installed for calibration in the NEL facility in December 1997 and following that a series of investigations were carried with the Manufacturer to resolve problems with the meter. However, although the meter was calibrated successfully at the Manufacturers premises, these results could no be replicated at NEL. The 400 mm flowmeter was calibrated in May 1998 at various flowrates and hence various fill heights, including full pipe conditions. The flowmeter was then calibrated at three fill heights chosen approximately in the lower half, at the middle, and in the upper half of the pipe line and the flowrates varied with the fill heights held nominally constant. 1 INTRODUCTION This is one of a series of evaluations carried out under DTI Flow Programme Project Reference WSDC54, on 200 mm and 400 mm nominal bore (NB) electromagnetic flowmeters designed for use in part filled and fully filled pipe flows. The calibrations were carried out in the large water flow facility at NEL. The facility is normally used for fully filled pipe flows, but a modified method of use allowed the water level in the test lines to be held steady at the selected value, whilst the flowrate was measured using the primary gravimetric system. This report gives the results of the flowmeter calibrations. A comprehensive report describing the flow measurement facility, test method and operational findings of the flowmeter is in preparation. 2 DETAILS OF THE ELECTROMAGNETIC FLOWMETERS mm NB Flowmeter Meter type: Manufacturer: Primary: Converter: PARTI MAG II range Bailey Fischer & Porter Model No ODP4111A Order No 9704L1080/A1 Model No 50XPZ101A Order No 9704L1080/B mm NB Flowmeter Meter type: Manufacturer: Primary: Converter: PARTI MAG II range Bailey Fischer & Porter Model No ODP4111A Order No 9703L0007/A1 Model No 50XP2101A Order No 9703L0007/B1 Report No: 195/99 Page 3 of?

5 Note: Both flowmeter were calibrated in water with the electrical conductivity varying between µs/cm. 3 METHOD OF TEST mm NB Flowmeter The 200 mm NB flowmeter was installed in the 200 mm NB test line with approximately 30D upstream and 14D downstream of similar diameter pipework. Care was taken to ensure that the flowmeter was mounted with the axis of the upper electrode pair horizontal using the spirit level installed in the primary junction box for this purpose. The flowmeter and the adjacent pipework along with the upstream pipework were level, and while the rest of the downstream pipework was running at a slight decline, the bubble in a spirit level used for checking this was either within or just over the appropriate line marking on the spirit level. Figure 1 shows the internal diameters of the pipework adjacent to the flowmeter. The fill heights were measured at the two perspex spool sections using a vernier height gauge and the mean value corrected to give the fill heights relative to the flowmeter mm NB Flowmeter The 400 mm NB flowmeter was installed in the NEL 457 mm NB pipe test line with approximately 20D upstream and 14.5D downstream of 400 mm NB pipework. The upstream pipework along with the flowmeter and its adjacent pipework were level while the rest of the downstream pipework was running at a slight decline. Figure 2 shows the internal diameters of the pipework adjacent to the flowmeter. The fill heights were measured at the perspex pipe section using the vernier height gauge and corrected to give the fill heights at the flowmeter. 4 UNCERTAINTY The large water test facility, used for the present calibrations, is NAMAS accredited with a best measurement capability uncertainty of 0.1 per cent of measured flow. The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of approximately 95 per cent. The uncertainty evaluation has been carried out in accordance with UKAS requirements. 5 RESULTS mm NB Flowmeter In the initial test in December 1997, covering several flowrates up to approximately 20 l/s, the flowmeter gave erroneous results. A representative from the manufacturer checked the flowmeter and a printed circuit board in the converter was changed. However, the flowmeter still gave erroneous results and it was decided to return the flowmeter to the factory for further examination. After the manufacturer had checked the meter, a representative from NEL witnessed the flowmeter being calibrated at the factory and it gave deviations within its specified uncertainty, which for this flowmeter is within 5 per cent for flowrates up to 6 l/s and 3 per cent for higher flowrates. Report No: 195/99 Page 4 of?

6 The flowmeter was returned to NEL and re installed in the NEL facility in January Test points were taken at various flowrates (and hence various fill heights) including full pipe conditions up to a flowrate of approximately 22 l/s. This was achieved by adjusting a valve upstream of the test line keeping all other valves in the test line open and the water allowed to fall under gravity to the weighbridge. At flowrates of approximately 3 l/s the flowmeter gave deviations of approximately 29 per cent. At flowrates of approximately 6.5 l/s to 16 l/s the deviation varied from 3 per cent to 6 per cent and at 30 l/s, (full bore conditions), the deviation was approximately 8 per cent. On further discussion with representatives from the manufacturer, it was thought the high electrical conductivity values of the water at NEL was causing the problem with the flowmeter affecting the lower pair of electrodes, although the information for this flowmeter does not specify any upper limit for the conductivity. It was decided to postpone further testing with this flowmeter until the problem had been resolved mm NB Flowmeter The calibration results are given in Tables 1 and 2. In the first part of the test, test point Nos 1 4, 11 15, 17 18, and 25 27, (Test No 3188C), the flowmeter was calibrated at various flowrates and hence various fill heights, including full pipe conditions, up to a flowrate of approximately 122 l/s. This was achieved by adjusting a valve upstream of the test line and the water allowed to fall under gravity to the weighbridge. These results are shown in Figure 3. In the second part of the test, the rest of the test points including the test points in Test No 3188D, were taken at three fill heights chosen approximately in the lower half, at the middle, and upper half of the flowmeter diameter and the flowrates varied up to 163 l/s. These conditions were achieved by adjusting the same upstream valve along with an additional valve at the downstream end of the test line. These results are shown in Figure 4. Test point Nos 13 and 14 are excluded from the graphs as they gave large deviations. This may have been due to the fill heights being close to the lower pair of electrodes and the high value for the electrical conductivity having an effect at this level. The velocities given in Tables 1 and 2 are mean values derived from the wetted cross sectional areas of the flowmeter and the volumetric flowrate in the pipe. Report No: 195/99 Page 5 of?

7 Report No: 195/99 Page 6 of?

8 Report No: 195/99 Page 7 of?

9 Report No: 195/99 Page 8 of?

10 Report No: 195/99 Page 9 of?

11 APPENDIX MANUFCTURER S SPECIFICTION FOR BAILEY FISCHER & PORTER, PARTI MAG II, ELECTROMAGNETIC FLOWMETERS FOR PART FILLED AND FULLY CHARGED PIPE FLOWS Report No: 195/99 Page 10 of?

1. Introduction. 2. API 5.7 Testing Protocol for Differential Pressure Flow Measurement Devices

1. Introduction. 2. API 5.7 Testing Protocol for Differential Pressure Flow Measurement Devices Testing the Wafer V-Cone Flowmeters in accordance with API 5.7 Testing Protocol for Differential Pressure Flow Measurement Devices in the CEESI Colorado Test Facility Dr R.J.W.Peters Flow Measurement Technology

More information

EXPERIMENTAL INVESTIGATION OF STROUHAL S NUMBER LINEARITY FOR DUAL TRAPEZOIDAL BLUFF BODY VORTEX FLOWMETER

EXPERIMENTAL INVESTIGATION OF STROUHAL S NUMBER LINEARITY FOR DUAL TRAPEZOIDAL BLUFF BODY VORTEX FLOWMETER ISSN: 244-787 EXPERIMENTAL INVESTIGATION OF STROUHAL S NUMBER LINEARITY FOR DUAL TRAPEZOIDAL BLUFF BODY VORTEX FLOWMETER ATUL S. BACHAL Mechanical Engineering Department Government College of Engineering

More information

ORIFICE FLOW METERS WITH CHAMBERS MEASURING RINGS

ORIFICE FLOW METERS WITH CHAMBERS MEASURING RINGS Bulletin E79 rev0 02/03/03 ORIFICE FLOW METERS WITH CHAMBERS MEASURING RINGS POP-U-S SERIES FEATURES UNI PN6 flanges: iron Chamber measuring rings: iron Disc: AISI30 Max. operating temperature: 00 C Max.

More information

GUIDANCE NOTE. Application of MEMS Ultrasonic Transducers to Flow Measurement.

GUIDANCE NOTE. Application of MEMS Ultrasonic Transducers to Flow Measurement. GUIDANCE NOTE Application of MEMS Ultrasonic Transducers www.tuvnel.com Application of MEMS Ultrasonic Transducers Introduction This Guidance Note provides a review of the key issues associated with the

More information

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems Features Certificate of calibration supplied with all sensors. Universal Mount Custom cell constant programmed into the electronics.

More information

Dave van Woensel 08 June Installation effects in ultrasonic gas flow meters Calibration results of a Z-configuration measurement skid

Dave van Woensel 08 June Installation effects in ultrasonic gas flow meters Calibration results of a Z-configuration measurement skid Dave van Woensel 08 June 2017 Installation effects in ultrasonic gas flow meters Calibration results of a Z-configuration measurement skid 1. Installation Effects 2. Skid Calibration 3. Results Ultrasonic

More information

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Features Test certificate supplied with all sensors Universal Mount Custom cell constant programmed into the

More information

The design and development of a force comparator standard machine to provide national traceability in force measurement to industry.

The design and development of a force comparator standard machine to provide national traceability in force measurement to industry. The design and development of a force comparator standard machine to provide national traceability in force measurement to industry. Speaker/ Author: S. Dlamini Co-author: C. Gouws National Metrology Institute

More information

Electromagnetic Field Measurement Survey

Electromagnetic Field Measurement Survey Electromagnetic Field Measurement Survey BS Number: Site Name: Site Address: Broadhurst Methodist Church Corner of Hukutswe and Kasane Roads Broadhurst 36 Broadhurst Methodist Church Site visit date: Site

More information

PROBE CONDITIONING SYSTEM- P/N FOR BATCH FURNACES

PROBE CONDITIONING SYSTEM- P/N FOR BATCH FURNACES December 3, 2007 PROBE CONDITIONING SYSTEM- P/N 13011 FOR BATCH FURNACES INSTRUCTION MANUAL M4505E SSi SUPER SYSTEMS INC. 7205 Edington Drive Cincinnati, Ohio 45249 1-513- 772-0060 1-800- 666-4330 FAX

More information

ENGR 83 Final Project

ENGR 83 Final Project ENGR 83 Final Project Affordable Flowmeter for Measurement of Low- Flowrate Suspended- Particulate Flow Julian Leland ENGR 83, 2011 Swarthmore College Introduction Measurement of fluid flow is an important

More information

Installation of force transducers

Installation of force transducers Installation of force transducers Force transducers have reached a high technical standard in recent years. Transducers achieve part of their high accuracy due to improved possibilities for calibration.

More information

INFLUENCE OF AFTERBODY SHAPE ANGLE OF TRAPEZOIDAL BLUFF BODY ON MEASURED SIGNAL PARAMETERS

INFLUENCE OF AFTERBODY SHAPE ANGLE OF TRAPEZOIDAL BLUFF BODY ON MEASURED SIGNAL PARAMETERS 27 P a g e INFLUENCE OF AFTERBODY SHAPE ANGLE OF TRAPEZOIDAL BLUFF BODY ON MEASURED SIGNAL PARAMETERS ATUL BACHAL Mechanical Department, Government College of Engineering Aurnagbad, MH, India, atul.bachal@in.endress.com

More information

Lowering of the Alcohol Limits for Drivers in Ireland and the Analytical Impact

Lowering of the Alcohol Limits for Drivers in Ireland and the Analytical Impact Lowering of the Alcohol Limits for Drivers in Ireland and the Analytical Impact Helen Kearns, Pauline Leavy, David Reynolds, Denis Cusack. Medical Bureau of Road Safety, University College Dublin. Abstract

More information

CSTR Digestion of Manure and Food Wastes. Co-Digestion of Manure and Food Wastes at Inland Empire California

CSTR Digestion of Manure and Food Wastes. Co-Digestion of Manure and Food Wastes at Inland Empire California CSTR Digestion of Manure and Food Wastes Co-Digestion of Manure and Food Wastes at Inland Empire California Torsten Fischer and Dr. Katharina Backes Krieg & Fischer Ingenieure GmbH Hannah-Vogt-Strasse

More information

Protein quantitation guidance (SXHL288)

Protein quantitation guidance (SXHL288) Protein quantitation guidance (SXHL288) You may find it helpful to print this document and have it to hand as you work onscreen with the spectrophotometer. Contents 1. Introduction... 1 2. Protein Assay...

More information

Choose smart valves for balancing Flow

Choose smart valves for balancing Flow Choose smart valves for balancing Flow For easy balancing of the flow NC Flow balancing valves NC Flow is designed for balancing heating and cooling systems. Incorrectly balanced flow is a common cause

More information

Fundamentals of Pressure Transducers

Fundamentals of Pressure Transducers print close Fundamentals of Pressure Transducers (Unpublished) Hydraulics & Pneumatics Alan Hitchcox Tue, 2013 09 17 (All day) Pressure is a key factor in almost every fluid power circuit. Pressure transducers

More information

Standard compliance - NDT performance demonstration in the CANDU industry

Standard compliance - NDT performance demonstration in the CANDU industry Paper Standard compliance - NDT performance demonstration in the CANDU industry Evan Choi, P.Eng. Project Manager CANDU Owners Group Abstract: CANDU nuclear power plants are operated in 3 provinces in

More information

Contents INTRODUCTION AND BACKGROUND 1. SECTION 1 Data collection methodology 2

Contents INTRODUCTION AND BACKGROUND 1. SECTION 1 Data collection methodology 2 Contents Page No INTRODUCTION AND BACKGROUND 1 SECTION 1 Data collection methodology 2 SECTION 2 5 DATASHEETS. 1. Push and pull strength 5 2. Push with the thumb or 2 or more fingers 11 3. Push with the

More information

Withdrawn at December 31, Guideline DKD-R 6-2. Calibration of Measuring Devices for Vacuum DEUTSCHER KALIBRIERDIENST. Part 1.

Withdrawn at December 31, Guideline DKD-R 6-2. Calibration of Measuring Devices for Vacuum DEUTSCHER KALIBRIERDIENST. Part 1. DEUTSCHER KALIBRIERDIENST Guideline DKD-R 6-2 Part 1 Calibration of Measuring Devices for Vacuum Fundamentals Edition 03/2002 Page 1 of 6 Published by the Accreditation Body of the Deutscher Kalibrierdienst

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CONBRACO CALIBRATION SERVICES 1418 S. Pearl Street Pageland, SC 29728 Scott McKay Phone: 843 672 1616 CALIBRATION Valid To: March 31,

More information

-SQA-SCOTTISH QUALIFICATIONS AUTHORITY HIGHER NATIONAL UNIT SPECIFICATION GENERAL INFORMATION MARCH

-SQA-SCOTTISH QUALIFICATIONS AUTHORITY HIGHER NATIONAL UNIT SPECIFICATION GENERAL INFORMATION MARCH -SQA-SCOTTISH QUALIFICATIONS AUTHORITY HIGHER NATIONAL UNIT SPECIFICATION GENERAL INFORMATION -Unit number- 3451068 -Unit title- -Superclass category- -Date of publication- (month and year) -Originating

More information

MONTANA FLUME. User s Manual. Montana (Short Parshall) Flume User s Manual

MONTANA FLUME. User s Manual. Montana (Short Parshall) Flume User s Manual MONTANA FLUME User s Manual i Montana (Short Parshall) Flume User s Manual TABLE OF CONTENTS Introduction to the Montana Flume... 1 Function... 1 Design... 1 Standards... 2 Accuracy... 3 Dimensions...

More information

Test-Report No.:

Test-Report No.: Date: 25-04-2016 Ear Plugs EN 352-2 Page 1 of 12 I. Device under test Test object: Universal ear plug Noizezz swim Trade name / Model reference: Noizezz sleep Noizezz fly State of construction: Production

More information

PART 1c: Time of Flight Diffraction Ultrasonic Inspector (TOFD) of Welds in Ferritic and Non-Ferritic Materials, Levels 1, 2 and 3

PART 1c: Time of Flight Diffraction Ultrasonic Inspector (TOFD) of Welds in Ferritic and Non-Ferritic Materials, Levels 1, 2 and 3 CERTIFICATION SCHEME FOR PERSONNEL DOCUMENT No. CSWIP-ISO-NDT-11/93-R Requirements for the Certification of Personnel Engaged in Non- Destructive Testing in accordance with the requirement of BS EN ISO

More information

Application(s) of Alanine

Application(s) of Alanine Application(s) of Alanine Simon Duane Radiotherapy Standards User Group, 5 June 2007 Outline Alanine/EPR dosimetry characteristics, usage (dis)advantages for reference dosimetry Traceable dosimetry for

More information

Sterilization of health care products Radiation. Part 3: Guidance on dosimetric aspects of development, validation and routine control

Sterilization of health care products Radiation. Part 3: Guidance on dosimetric aspects of development, validation and routine control Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 11137-3 Second edition 2017-06 Sterilization of health care products Radiation Part 3: Guidance on dosimetric aspects of development, validation

More information

DURASEAL. High Integrity, Double Block and Bleed Plug Valve.

DURASEAL. High Integrity, Double Block and Bleed Plug Valve. DURASEAL High Integrity, Double Block and Bleed Plug Valve www.franklinvalve.com How the DuraSeal Works An improved valve with a proven history We took an alternative path. Unlike many valve manufacturers

More information

Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy

Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy Simon Duane, Hugo Palmans, Peter Sharpe NPL, UK Stefaan Vynckier UCL, Brussels, Belgium LNE-LNHB / BIPM workshop,

More information

CORESTA RECOMMENDED METHOD NÄ 9

CORESTA RECOMMENDED METHOD NÄ 9 CORESTA RECOMMENDED METHOD NÄ 9 DETERMINATION OF NICOTINE IN CIGARETTE FILTERS BY GAS CHROMATOGRAPHIC ANALYSIS (April 2009) 0. INTRODUCTION In 2001 the CORESTA Routine Analytical Chemistry Sub-Group was

More information

COLD LEAD OPTIONS FOR XMI MINERAL INSULATED (MI) HEATING CABLES

COLD LEAD OPTIONS FOR XMI MINERAL INSULATED (MI) HEATING CABLES FOR XMI MINERAL INSULATED (MI) HEATING CABLES PRODUCT OVERVIEW XMI with standard MI cold lead and Type X connector MI cable heated section PRODUCT OVERVIEW XMI with PyroFLX cold lead and Type K connector

More information

Convex Array Transducer

Convex Array Transducer User Guide Type 8802 Convex Array Transducer English BB0334-I August 2012 For Professional Users Only WORLD HEADQUARTERS Mileparken 34 DK-2730 Herlev Denmark Tel.:+45 44528100 / Fax:+45 44528199 www.bkmed.com

More information

Drug and Alcohol Management within the workplace

Drug and Alcohol Management within the workplace Drug and Alcohol Management within the workplace Introduction A business of any size can experience issues relating to drug and alcohol misuse at some point with their employees. It has become a growing

More information

4-20 ma Pressure Transducer

4-20 ma Pressure Transducer 4-20 ma Pressure Transducer 56410099 Copyright 2017 Durham Geo Slope Indicator All Rights Reserved. This equipment should be installed, maintained, and operated by technically qualified personnel. Any

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 11904-1 First edition 2002-10-01 Acoustics Determination of sound immission from sound sources placed close to the ear Part 1: Technique using a microphone in a real ear (MIRE

More information

GUIDANCE ON MINIMUM UNIT PRICING FOR RETAILERS GUIDANCE ON MINIMUM UNIT PRICING FOR RETAILERS

GUIDANCE ON MINIMUM UNIT PRICING FOR RETAILERS GUIDANCE ON MINIMUM UNIT PRICING FOR RETAILERS GUIDANCE ON MINIMUM UNIT PRICING FOR RETAILERS GUIDANCE ON MINIMUM UNIT PRICING FOR RETAILERS MARCH 2018 1 WELCOME One of the key aims of SGF is to promote responsible community retailing. This guide is

More information

Influence of Frequency on Difference Thresholds for Magnitude of Vertical Sinusoidal Whole-Body Vibration

Influence of Frequency on Difference Thresholds for Magnitude of Vertical Sinusoidal Whole-Body Vibration Industrial Health 2002, 40, 313 319 Original Article Influence of Frequency on Difference Thresholds for Magnitude of Vertical Sinusoidal Whole-Body Vibration Yasunao MATSUMOTO 1 *, Setsuo MAEDA 2 and

More information

ATyS Bypass Enclosed solution from 40 to 3200 A

ATyS Bypass Enclosed solution from 40 to 3200 A ATyS Bypass Enclosed solution from 40 to 3200 A A complete enclosed range of ATyS dedicated to bypass function Architecture SINGLE LINE DOUBLE LINE Voltage Sensing Voltage Sensing RANGE FROM 40 TO 3200

More information

Morgan Sindall. NW PSBP Dee Point Primary School. Environmental Noise Report. Job No: RPT Latest Revision: - Date: 1/10/2014

Morgan Sindall. NW PSBP Dee Point Primary School. Environmental Noise Report. Job No: RPT Latest Revision: - Date: 1/10/2014 Morgan Sindall NW PSBP Dee Point Primary School Environmental Noise Report Job No: 1010273 Doc No: 1010273-RPT-00001 Latest Revision: - Date: 1/10/2014 Cundall Johnston and Partners LLP 4th Floor Cathedral

More information

UKAS Guidance on the Application of ISO/IEC Dealing with Expressions of Opinions and Interpretations

UKAS Guidance on the Application of ISO/IEC Dealing with Expressions of Opinions and Interpretations LAB 13 Expression of opinions & interpretations UKAS Guidance on the Application of ISO/IEC 17025 Dealing with Expressions of Opinions and Interpretations [UKAS Publication ref: LAB 13] Contents Section

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 6565 Fifth edition 2015-12-15 Tobacco and tobacco products Draw resistance of cigarettes and pressure drop of filter rods Standard conditions and measurement Tabac et produits

More information

The General Practice Research Database (GPRD) Further Information for Patients

The General Practice Research Database (GPRD) Further Information for Patients The General Practice Research Database (GPRD) Further Information for Patients The General Practice Research Database (GPRD) What is the GPRD? The GPRD is a computerised database of anonymised data from

More information

SUCCESS STORY. Bürkert < > Novo Nordisk A new formulation line for insulin vials

SUCCESS STORY. Bürkert < > Novo Nordisk A new formulation line for insulin vials SUCCESS STORY Bürkert < > Novo Nordisk A new formulation line for insulin vials 2 SUCCESS STORY Novo Nordisk 3 A new formulation line for insulin vials Diaphragm valve type 2103 with control head type

More information

Convex Array Transducer

Convex Array Transducer User Guide Type 8823 Convex Array Transducer English BB1740-C June 2012 For Professional Users Only BK MEDICAL Mileparken 34 2730 Herlev Denmark Tel.:+45 4452 8100 / Fax:+45 4452 8199 www.bkmed.com Email:

More information

CONE-MTG RADIAL (Y) Deflection (mm) CONE-MTG AX IAL (X ) Deflec tion (mm)

CONE-MTG RADIAL (Y) Deflection (mm) CONE-MTG AX IAL (X ) Deflec tion (mm) Ø. Ø. Ø. Ø.. CRS. Ø. Ø. Ø.. CRS. Ø. Cone Mountings: Section Tel: (+)()9 77 Fax: (+)()9 7 E-mail: sales@gmtrubber.com www.gmtrubber.com Cone Mountings A range of sizes is available with many held in stock.

More information

Qualification and Performance Specification for Rigid Printed Boards

Qualification and Performance Specification for Rigid Printed Boards Qualification and Performance Specification for Rigid Printed Boards Developed by the Rigid Printed Board Performance Specifications Task Group (D-33a) of the Rigid Printed Board Committee (D-30) of IPC

More information

CASE STUDY: Solution for PD Pump Suction Piping System Pulsation/Vibration Problem

CASE STUDY: Solution for PD Pump Suction Piping System Pulsation/Vibration Problem CASE STUDY: Solution for PD Pump Suction Piping System Pulsation/Vibration Problem Eugene L. Broerman, III Buddy Sr. Research Engineer Ray G. Durke Sr. Research Engineer Southwest Research Institute Author

More information

Qingtian Instrument Kaifeng Qingtianweiye Flow Instrument Co.,Ltd

Qingtian Instrument Kaifeng Qingtianweiye Flow Instrument Co.,Ltd Qingtian Instrument Kaifeng Qingtianweiye Flow Instrument Co.,Ltd Section One Company Profile 2 Kaifeng Qingtianweiye Flow instrument Co., Ltd was founded in 2005,located in China flow instrument production

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 15197 First edition 2003-05-01 In vitro diagnostic test systems Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus Systèmes d'essais

More information

A Novel Phased Array Ultrasonic Testing (PAUT) System for On-Site Inspection of Welded Joints in Plastic Pipes

A Novel Phased Array Ultrasonic Testing (PAUT) System for On-Site Inspection of Welded Joints in Plastic Pipes 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic More Info at Open Access Database www.ndt.net/?id=16621 A Novel Phased Array Ultrasonic Testing

More information

CORESTA RECOMMENDED METHOD N 22

CORESTA RECOMMENDED METHOD N 22 CORESTA RECOMMENDED METHOD N 22 ROUTINE ANALYTICAL CIGARETTE-SMOKING MACHINE SPECIFICATIONS, DEFINITIONS AND STANDARD CONDITIONS (August 1991) 0. INTRODUCTION This CORESTA Recommended Method includes the

More information

Analysis of the human risk factor which affects the reliability and safety of machinery

Analysis of the human risk factor which affects the reliability and safety of machinery Safety and Security Engineering VI 287 Analysis of the human risk factor which affects the reliability and safety of machinery G. Hotta 1, D. Ishibashi 1, Y. Ohbuchi 2 & H. Sakamoto 3 1 Department of Mechanical

More information

AN ULTRASONIC MESH SENSOR FOR TWO-PHASE FLOW VISUALISATION

AN ULTRASONIC MESH SENSOR FOR TWO-PHASE FLOW VISUALISATION AN ULTRASONIC MESH SENSOR FOR TO-PHASE FLO ISUALISATION.. Kontelev,. I. Melnikov Technical State University of Nishny Novgorod, Russian Federation 1. Introduction This paper presents an ultrasonic mesh

More information

The Efficacy of a Self-Harm Awareness Training Programme

The Efficacy of a Self-Harm Awareness Training Programme The Efficacy of a Self-Harm Awareness Training Programme Report of an Independent Evaluation Dr. Ella Arensman Ms. Claire Coffey National Suicide Research Foundation Commissioned by the National Office

More information

Alcohol Related Harm in Western Australia

Alcohol Related Harm in Western Australia Occasional Paper Number 11 Alcohol Related Harm in Western Australia Drug and Alcohol Office Department of Health May 2002 This publication is available on the WA Drug Strategy web site http://www.wa.gov.au/drugwestaus

More information

UK National Aerospace NDT Board

UK National Aerospace NDT Board UK National Aerospace NDT Board c/o The British Institute of NDT Newton Building, St George s Avenue Northampton, NN2 6JB United Kingdom Tel: +44 (0)1604-893-811. Fax: +44 (0)1604-893-868. E-mail: Nicole.scutt@bindt.org

More information

IMPACT OF DEPENDENT FAILURE ON SIL ASSESSMENT

IMPACT OF DEPENDENT FAILURE ON SIL ASSESSMENT IMPACT OF DEPENDENT FAILURE ON SIL ASSESSMENT Alan G King ABB Engineering Services, Pavilion 9, Belasis Hall Technology Park, Billingham, Cleveland TS23 4YS, UK; Tel: þ44 (0) 1642 372252, Fax: þ44 (0)

More information

AviagenBrief. Evaluating Comparative Broiler Performance through Trials INTRODUCTION KEY CONSIDERATIONS. November 2018

AviagenBrief. Evaluating Comparative Broiler Performance through Trials INTRODUCTION KEY CONSIDERATIONS. November 2018 AviagenBrief Evaluating Comparative Broiler Performance through Trials INTRODUCTION November 2018 Carefully planned broiler trials will allow the customer to clearly evaluate the effect of the treatment,

More information

High Frequency Linear Array Transducer

High Frequency Linear Array Transducer User Guide Type 8870 High Frequency Linear Array Transducer English BB1980-C May 2016 For Professional Users Only BK MEDICAL Mileparken 34 2730 Herlev Denmark Tel.:+45 4452 8100 / Fax:+45 4452 8199 www.bkultrasound.com

More information

Length: 507 mm Width: 581 mm Height: 854 mm. Materials: Frame: Ø16 mm metal tubes Shell: 6 mm plastic

Length: 507 mm Width: 581 mm Height: 854 mm. Materials: Frame: Ø16 mm metal tubes Shell: 6 mm plastic Four Design A/S Faaborgvej 14 DK-5854 Gislev Order no. 645296-2-1 Appendices 2 Test Report Material: Model: Four Cast 2 Four Type: Chair Length: 507 mm Width: 581 mm Height: 854 mm Weight: 5,7 kg Materials:

More information

Study protocol. Version 1 (06 April 2011) Ethics ref: R&D ref: UK CRC portfolio ID:

Study protocol. Version 1 (06 April 2011) Ethics ref: R&D ref: UK CRC portfolio ID: Identifying and prioritising important research questions for the treatment of eczema a collaborative partnership between patients, carers, clinicians and researchers Study protocol Version 1 (06 April

More information

ER75 Electro-Acoustic Ear Simulator. Operating Manual

ER75 Electro-Acoustic Ear Simulator. Operating Manual ER75 Electro-Acoustic Ear Simulator Operating Manual ABOUT THIS MANUAL READ THIS OPERATING MANUAL BEFORE ATTEMPTING TO USE THE INSTRUMENT. Amplivox Ltd. 6 Oasis Park, Eynsham Oxfordshire, OX29 4TP United

More information

Effects Of Red Blood Cell Aggregation On Wall Shear Stress In µ-tube System

Effects Of Red Blood Cell Aggregation On Wall Shear Stress In µ-tube System Effects Of Red Blood Cell Aggregation On Wall Shear Stress In µ-tube System Tan Z. 1, Yang S 2 and Kim S.H. 3 Division of Bioengineering, Faculty of Engineering, National University of Singapore 21 Lower

More information

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 6.3 PSYCHOLOGICAL EVALUATION

More information

HIGHLANDS STRONGMAN COMPETITION

HIGHLANDS STRONGMAN COMPETITION Power is often associated with mechanical engines, or electrical motors. Many other devices also produce power. Light bulbs dissipate power in order to provide light. The human body converts stored energy

More information

Dynamic Routing Applied to an Urban Subsurface Drainage System

Dynamic Routing Applied to an Urban Subsurface Drainage System Dynamic Routing Applied to an Urban Subsurface Drainage System Michelle Iblings, PE, CFM (Freese and Nichols, Inc.) Jim Dulac,, PE (City of Richardson) TFMA Spring Conference May 1, 2008 Project Overview

More information

PETROSYSTEM Srl OG METER SERIES

PETROSYSTEM Srl OG METER SERIES 02-08.1 OG METER SERIES High accuracy oval gear meters Excellent chemical resistance Rugged construction Individual multi-point calibration Proved design Comprehensive product range High viscosità capability

More information

DOSIMETRY PRODUCTS & SERVICES 2018 PRICE LIST

DOSIMETRY PRODUCTS & SERVICES 2018 PRICE LIST DOSIMETRY PRODUCTS & SERVICES 2018 PRICE LIST Dosimetry Products & Services Dosimetry and Calibration Products and Services All prices are in Canadian Dollars. Delivery for most items is 6 weeks subject

More information

Basic Press Information

Basic Press Information Basic Press Information Contact MedAustron EBG MedAustron GmbH Marie Curie-Strasse 5 A-2700 Wiener Neustadt Austria T +43 2622 26 100-0 e-mail: office@medaustron.at Internet: www.medaustron.at Press contact:

More information

Chapter 20: Test Administration and Interpretation

Chapter 20: Test Administration and Interpretation Chapter 20: Test Administration and Interpretation Thought Questions Why should a needs analysis consider both the individual and the demands of the sport? Should test scores be shared with a team, or

More information

Reducing the Health Risks from Radon in the UK Overground Workplace

Reducing the Health Risks from Radon in the UK Overground Workplace Reducing the Health Risks from Radon in the UK Overground Workplace A.R.Denman School of Health, The University of Northampton, Northampton, NN2 7AL, UK. Abstract. In response to the potential health risk

More information

Sterile hypodermic needles for single use Requirements and test methods

Sterile hypodermic needles for single use Requirements and test methods Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 7864 Fourth edition 2016-08-01 Sterile hypodermic needles for single use Requirements and test methods Aiguilles hypodermiques stériles, non réutilisables

More information

IPC-6018A. Microwave End Product Board Inspection and Test IPC-6018A. A standard developed by IPC. Supersedes IPC-6018 January 1998

IPC-6018A. Microwave End Product Board Inspection and Test IPC-6018A. A standard developed by IPC. Supersedes IPC-6018 January 1998 ASSOCIATION CONNECTING ELECTRONICS INDUSTRIES Microwave End Product Board Inspection and Test January 2002 A standard developed by IPC Supersedes IPC-6018 January 1998 2215 Sanders Road, Northbrook, IL

More information

Standards. Certification. Education & Training. Publishing. Conferences & Exhibits. Table of Contents. View Excerpt. Buy the Book

Standards. Certification. Education & Training. Publishing. Conferences & Exhibits. Table of Contents. View Excerpt. Buy the Book Standards Certification Education & Training Publishing Conferences & Exhibits Table of Contents View Excerpt Buy the Book Industrial Flow Measurement 3rd Edition David W. Spitzer Notice The information

More information

Honorable Mayor and Members of the City Council. Mitigation Agreement with Safeway for Expansion at 6310 College Avenue, Oakland

Honorable Mayor and Members of the City Council. Mitigation Agreement with Safeway for Expansion at 6310 College Avenue, Oakland Public Works Department CONSENT CALENDAR July 17, 2012 To: From: Honorable Mayor and Members of the City Council Christine Daniel, City Manager Submitted by: Andrew Clough, Director, Public Works Subject:

More information

SHRUGs national report Information & Statistics Division The National Health Service in Scotland Edinburgh June 2000

SHRUGs national report Information & Statistics Division The National Health Service in Scotland Edinburgh June 2000 Scottish Health Resource Utilisation Groups SHRUGs national report 1999 Information & Statistics Division The National Health Service in Scotland Edinburgh June 2000 Contents -- click on the section of

More information

An ISO 9001:2008 Certified Company

An ISO 9001:2008 Certified Company NDT Procedure for Magnetic Partcle Inspection NDT Procedure suitable for General Magnetic Particle Inspections. This is a sample MT procedure and may be required to be modified as per Clients / Projects

More information

ilearnalignment Training topics covered in the introduction and master versions

ilearnalignment Training topics covered in the introduction and master versions ilearnalignment Training topics covered in the introduction and master versions ilearnalignment [Introduction] If you need an introduction to shaft alignment in order to understand the benefits and the

More information

Frequently Asked Questions

Frequently Asked Questions Frequently Asked Questions How does the SMRT-Y work? The SMRT-Y sensor accurately measures the moisture level in the soil. When the soil is dry, the SMRT-Y allows the irrigation controller to water as

More information

Patient Group Direction for the Supply of Orlistat (Xenical) from Designated Community Pharmacies

Patient Group Direction for the Supply of Orlistat (Xenical) from Designated Community Pharmacies Patient Group Direction for the Supply of Orlistat (Xenical) from Designated Community Pharmacies Written by: Sheila Brown, Prescribing Adviser Date: September 2006 Reviewed by: Date: Ratified by: East

More information

Materials: scale metric ruler stairs stopwatch

Materials: scale metric ruler stairs stopwatch Lab # : Power Work-Out Lab Name: Period: Date: Partner name (s): Purpose: 1. To approximate how much work and power your body generates against gravity when climbing stairs and when performing a physical

More information

EVALUATION OF THE CYCLEX IMPACTOR PHASE 2: REPORT 3

EVALUATION OF THE CYCLEX IMPACTOR PHASE 2: REPORT 3 EVALUATION OF THE CYCLEX IMPACTOR PHASE 2: COLLECTION EFFICIENCY EVALUATION WITH MICROBIAL SPORES (IMPACTOR S CONFIGURATIONS 1, 2, AND 3) REPORT 3 Submitted to: ENVIRONMENTAL MONITORING SYSTEMS, INC. Prepared

More information

Chair and Members, The Etobicoke York Community Council. Mark Sraga, Director and Deputy Chief Building Official

Chair and Members, The Etobicoke York Community Council. Mark Sraga, Director and Deputy Chief Building Official STAFF REPORT ACTION REQUIRED Sign Variance Report 2150 Lake Shore Blvd W Date: October 27, 2009 To: From: Chair and Members, The Etobicoke York Community Council Mark Sraga, Director and Deputy Chief Building

More information

Current Voltage characteristic of biological tissue: Body resistance

Current Voltage characteristic of biological tissue: Body resistance 6_Current Voltage characteristic of biological tissue.xlsx/work procedure Study group: Year of study: Current Voltage characteristic of biological tissue: Body resistance Objective: Establish the mean

More information

Discussion of Technical Issues Required to Implement a Frequency Response Standard

Discussion of Technical Issues Required to Implement a Frequency Response Standard Reference 1 Discussion of Technical Issues Required to Implement a Frequency Response Standard Howard F. Illian Abstract NERC is investigating the implementation of a Frequency Response Standard on the

More information

Novel Modifications of Twin-fluid Atomizers: Performance, Advantages and Drawbacks

Novel Modifications of Twin-fluid Atomizers: Performance, Advantages and Drawbacks ILASS Europe 010, 3rd Annual Conference on Liquid Atomization and Spray Systems, Brno, Czech Republic, September 010 J. Jedelsky * and M. Jicha Faculty of Mechanical Engineering Brno University of Technology

More information

IsoAcoustics Technology Explained!

IsoAcoustics Technology Explained! IsoAcoustics Technology Explained! IsoAcoustics Inc. has been developing products for the audio industry since January 2012. IsoAcoustics produces a growing range of products for both Home Audio and Professional

More information

Alcohol and Tobacco Available for Consumption: Year ended December 2009

Alcohol and Tobacco Available for Consumption: Year ended December 2009 Embargoed until 10:45am 19 February 2010 Alcohol and Tobacco Available for Consumption: Year ended December 2009 Highlights For the December 2009 year compared with the December 2008 year unless otherwise

More information

SAFETY SHOWERS AND EYEWASHES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

SAFETY SHOWERS AND EYEWASHES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS 224500 SAFETY SHOWERS AND EYEWASHES PART 1 GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 013010 Accessibility for People with Disabilities B. Section 115000 Laboratory Equipment

More information

Technical Data Sheet SONOFLOW CO.55 V1.0

Technical Data Sheet SONOFLOW CO.55 V1.0 Technical Data Sheet SONOFLOW CO.55 V1.0 The sensor series SONOFLOW CO.55 V1.0 designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a

More information

Pictures for illustration purposes only. Hearing loop solutions. Selecting the best solution for your requirement

Pictures for illustration purposes only. Hearing loop solutions. Selecting the best solution for your requirement Hearing loop solutions Selecting the best solution for your requirement Listen to the difference Hearing loop solutions A hearing loop, also known as an induction loop or T-Loop, is an assistive listening

More information

Liquid level transmitter Type AKS 41 / 41U REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Liquid level transmitter Type AKS 41 / 41U REFRIGERATION AND AIR CONDITIONING. Technical leaflet Liquid level transmitter Type AKS 41 / 41U REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3

More information

Clay Sewer Pipe-Joint Infiltration Leak-Rate Testing

Clay Sewer Pipe-Joint Infiltration Leak-Rate Testing Clay Sewer Pipe-Joint Infiltration Leak-Rate Testing 1. ABSTRACT While numbers of small to large older cities are undertaking repairs and maintenance, several other newer cities are planning on installing

More information

Glass Body Fat Scale Instructions for use

Glass Body Fat Scale Instructions for use Glass Body Fat Scale Instructions for use The scale is specially designed to test your body weight, body fat, hydration, muscle and bone percentages and to help you keep a close eye on the daily changes

More information

Performance evaluation of force transducers

Performance evaluation of force transducers Indian Journal of Pure & Applied Physics Vol. 50, February 2012, pp. 86-90 Performance evaluation of force transducers Harish Kumar 1,2 * & Chitra Sharma 3 1 CSIR-National Physical Laboratory, New Delhi

More information

Please see the attached drug alert for onward transmission as below.

Please see the attached drug alert for onward transmission as below. Chief Medical Officer Directorate Pharmacy and Medicines Division T: 0131-244 2528 E: irene.fazakerley@gov.scot IMMEDIATE MESSAGE TO: 1. Directors of Pharmacy 2. Medical Directors NHS Boards 18 April 2018

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Suite S01a Kestrel Court Harbour Road Portishead Bristol BS20 7AN Contact: Mr James Gibb Tel: +44 (0) 1275 390 568 Email: jg@advancedcertification.co.uk

More information

Childcare Provider Satisfaction Survey Report

Childcare Provider Satisfaction Survey Report Childcare Provider Satisfaction Survey Report 450525 / April 2005 Prepared for: Ofsted Office for Standards in Education Prepared by: NOP Social and Political Ludgate House 245 Blackfriars Road London

More information

WOMEN ENTREPRENEUR PROBLEMS- ANOVA TEST BETWEEN FAMILY CONSTRAINTS AND FACTORS FOR SUCCESS

WOMEN ENTREPRENEUR PROBLEMS- ANOVA TEST BETWEEN FAMILY CONSTRAINTS AND FACTORS FOR SUCCESS WOMEN ENTREPRENEUR PROBLEMS- ANOVA TEST BETWEEN FAMILY CONSTRAINTS AND FACTORS FOR SUCCESS Dr.S.Valli Devasena Assistant Professor of Commerce, Mother Teresa Women s University, Kodaikanal, Dindigul Dt..

More information