The hemodynamic effects of artificial ventilation. Determinants of Aortic Pressure Variation During Positive-Pressure Ventilation in Man*

Size: px
Start display at page:

Download "The hemodynamic effects of artificial ventilation. Determinants of Aortic Pressure Variation During Positive-Pressure Ventilation in Man*"

Transcription

1 Determinants of Aortic Pressure Variation During Positive-Pressure Ventilation in Man* André Y. Denault, MD; Thomas A. Gasior, MD; John Gorcsan III, MD; William A. Mandarino, MSME; Lee G. Deneault, MS; and Michael R. Pinsky, MD, FCCP Study objectives: To define the relation between systolic arterial pressure (SAP) changes during ventilation and left ventricular (LV) performance in humans. Design: Prospective repeat-measures series. Setting: University of Pittsburgh Medical Center Operating Room. Patients: Fifteen anesthetized cardiac surgery patients before and after cardiopulmonary bypass when the mediastinum was either closed or open. Interventions: Positive-pressure ventilation. Measurements and results: SAP and LV midaxis cross-sectional areas were measured during apnea and then were measured for three consecutive breaths. SAP increased during inspiration, this being the greatest during closed chest conditions (p < 0.05). Changes in SAP could not be correlated with changes in either LV end-diastolic areas (EDAs), end-systolic areas, or stroke areas (SAs). If SAP decreased relative to apnea, the decrease occurred during expiration and was often associated with increasing LV EDAs and SAs. SAP often decreased after a positive-pressure breath, but the decrease was unrelated to SA deficits during the breath. Increases in SAP were in phase with increases in airway pressure, whereas decreases in SAP, if present, followed inspiration. No consistent relation between SAP variation and LV area could be identified. Conclusions: In this patient group, changes in SAP reflect changes in airway pressure and (by inference) intrathoracic pressure (as in a Valsalva maneuver) better than they reflect concomitant changes in LV hemodynamics. (CHEST 1999; 116: ) Key words: cardiovascular function; heart-lung interactions; hemodynamic monitoring; pulsus paradoxus Abbreviations: ABD automated border detector; 2D two dimensional; down maximum decrease in SAP after a positive-pressure breath, as compared to apneic SAP; EDA end-diastolic area; ESA end-systolic area; IABP intra-aortic balloon pump; ITP intrathoracic pressure; LV left ventricular; Ppao pulmonary artery occlusion pressure; SA stroke area; SAP systolic arterial pressure; TEE transesophageal echocardiography; up maximum increase in SAP during the positive-pressure breath, as compared to apneic SAP; Vt tidal volume The hemodynamic effects of artificial ventilation are complex, interrelated, and dependent on the initial cardiovascular state of the subject. 1 It has been proposed that the aortic pressure variation in response to a positive-pressure breath can be used to define, in a nonambiguous fashion, the primary determinants of the existing hemodynamic state. 2 If *From the Department of Anesthesiology and Critical Care Medicine (Drs. Denault, Gasior, and Pinsky, and Mr. Deneault) and the Division of Cardiology (Dr. Gorcsan and Mr. Mandarino), Department of Medicine, University of Pittsburgh Medical Center, Pittsburgh, PA. Support for this study was provided by the Veterans Administration. Manuscript received May 13, 1997; revision accepted February 16, Correspondence to: Michael R. Pinsky, MD, FCCP, 604 Scaife Hall, 3550 Terrace St, Pittsburgh, PA 15261; pinsky@ smtp.anes.upmc.edu correct, this bedside test would be useful for evaluating the hemodynamic condition for all patients requiring mechanical ventilation. In the present study, we sought to define the determinants of aortic pressure variation relative to estimates of left ventricular (LV) area and function in humans. Several investigators have defined ventilation-associated changes in arterial pressure as the variable that would define overall heart-lung interactions. Perel et al 2 observed that, when compared with an apneic baseline, systolic arterial pressure (SAP) decreased more in response to a positive-pressure breath in dogs that were hemorrhaged and presumably more preload-dependent, than in animals that were fluid resuscitated. This suggested to these investigators that in preload-dependent states, posi- 176 Clinical Investigations in Critical Care

2 tive-pressure breathing decreased SAP by decreasing the LV preload. Massumi et al 3 observed that SAP may also increase after positive-pressure ventilation in patients with LV failure. They called this observation reversed pulsus paradoxus. Pizov et al 4 demonstrated a similar phenomenon in dogs with acute ventricular failure, but only following fluid resuscitation. These data led them to speculate that once LV preload was adequate (following fluid resuscitation), positive-pressure ventilation-induced changes in intrathoracic pressure (ITP) would augment the LV ejection by reducing the LV afterload. 5 The increase in SAP in their studies was thought to represent the associated increase in LV stroke volume. Whether or not LV stroke volume increases during positive-pressure inspiration in heart failure and the mechanisms by which LV stroke volume increases are not known. Potentially, LV stroke volume could increase by one of three mechanisms: (1) an increase in LV filling (increased end-diastolic volume), as the alveolar vessels are compressed during inspiration 6 ; (2) a decrease in right ventricular residual enddiastolic volume, which increases LV diastolic compliance 7 ; or (3) a decrease in afterload (decreased end-systolic volume), as the increase in ITP during positive-pressure inspiration decreases the transmural LV ejection pressure. 1,5 Although it is tempting to conclude that changes in SAP during positive-pressure ventilation reflect perturbations in LV preload and afterload, the relation between changes in SAP and ventricular volumes during ventilation is unknown. Furthermore, the mechanism by which SAP varies during ventilation could involve processes independent of changes in the LV preload or afterload. SAP could vary during positive-pressure ventilation because of a direct transmission of the increased ITP to the aorta in a fashion analogous to phases 1 and 2 of a Valsalva maneuver. Inspiration would increase SAP similarly to the way it increases in the initial phase of a Valsalva maneuver. 8 If this were the case, stroke volume would eventually decrease because of the associated decrease in venous return, 9 although SAP would remain elevated as long as ITP remained elevated. Most importantly, however, is that the increase in SAP would be in phase with inspiration, whereas any decrease in SAP would not. Furthermore, SAP could decrease during positive-pressure expiration because of the withdrawal of ITP-supported arterial pressure in the setting of a decreased aortic blood volume and in a fashion analogous to the release phase (phase 3) of a Valsalva maneuver. Here the decrease in SAP would invariably follow inspiration but need not reflect a decrease in stroke volume. Furthermore, these ventilation-associated changes in SAP need not be related to changes in LV volume, nor do they need to be influenced to a relative degree by the level of LV contractility, but they would reflect only the changes in ITP. To separate these mechanisms, we studied the effect of positive-pressure ventilation on SAP and the LV midaxis cross-sectional area in patients undergoing coronary artery bypass surgery. We tested the hypothesis that changes in SAP during a positivepressure breath are induced solely by in-phase changes in ITP and need not reflect changes in stroke volume, end-diastolic volume, or end-systolic volume. We reasoned that if the inspiration-associated increases in the pulmonary blood flow 6 increased the LV preload, thus increasing SAP, then the increase in SAP would be similar whether the chest was open or closed, because changes in ITP would not primarily alter this interaction. However, if changes in ITP or ventricular interdependence were the primary factors altering LV SAP or preload, respectively, then closing the chest would accentuate the effect by inducing greater amounts of increased ITP and reduced systemic venous return. Finally, since Perel et al 10 initially described this phenomena in patients following a cardiopulmonary bypass, we strove to assess the above interaction both before and after a bypass to ascertain whether the hemodynamic alterations known to occur following a bypass altered the subjects response. 11 Patients Materials and Methods After approval of our protocol by the Institutional Review Board committee of the University of Pittsburgh, we studied 17 sequential patients undergoing elective coronary artery bypass surgery at the University of Pittsburgh Medical Center. The first 15 patients studied on the protocol are described below, whereas the last 2 patients were used to validate the accuracy of the LV area measurements. Informed consent was obtained. Profiles of the 15 initial patients are summarized in Table 1. General anesthesia was induced by using high-dose narcotics and oxygen with no inhalation anesthetics. All patients were instrumented and monitored with a flow-directed balloon-tipped pulmonary artery catheter, central aortic catheter (femoral arterial line), endotracheal tube, and ECG. Airway pressure at the proximal end of the endotracheal tube was also monitored, and ventilation was provided with a volume-cycled ventilator (Servo Ventilator 900; Siemens-Elena; Solna, Sweden). All pressures were calibrated at zero at the midaxillary level, and they were transduced by using high-displacement transducers (TXX-R; Viggo-Spectramed; Oxnard, CA). We excluded patients with a contraindication to the use of transesophageal echocardiography (TEE), simultaneous use of an intra-aortic balloon pump (IABP), lack of sinus rhythm, numerous premature ventricular complexes during the data acquisition periods, and the inability to obtain an adequate transgastric view from the midpapillary level. In the criteria put forward by Schnittger et al, 12 an inadequate echocardiographic view was CHEST / 116 / 1/ JULY,

3 Table 1 Steady-State Apneic Hemodynamic Data* Subject Systolic Pa, Diastolic Pa, HR, min 1 CO, L/min FAC, % Ppao, Pra, Systolic Ppa, Diastolic Ppa, NA NA NA NA *CO cardiac output; FAC fractional area of contraction; HR heart rate; NA not available; Pa arterial pressure; Ppa pulmonary artery pressure; Pra right atrial pressure. defined as 75% of the perimeter of the ventricular image being defined by contiguous endocardial echoes. In practice, no patients were excluded because of a contraindication to the use of the TEE, and only 2 patients out of 17 were excluded because of the inability to obtain an appropriate echocardiographic image. The TEE probe was positioned at the beginning of the experiment and not moved until the data acquisition was completed. As a further form of quality control, the quality of the TEE images was analyzed on-line by a cardiac anesthesiologist. The images were recorded on videotape and reviewed by a cardiologist who specialized in echocardiography, using the same criteria. Because the purpose of our study was to examine the effect of positivepressure on LV volume and SAP, subsequent analysis was performed using only the TEE images that both observers, who were blinded to the other s opinions, agreed were acceptable in quality. Transesophageal Echocardiographic Examination Two-dimensional (2D) TEE signals were acquired by an echocardiographic automated border detector ([ABD]; Sonos 1500; Hewlett Packard Systems; Andover, CA). This methodology has been described and validated previously for this type of patient population. 13 Briefly, an automated-edge border-detection algorithm is superimposed on the 2D echocardiographic image and displayed in real time on the video monitor as a red line that follows the endocardial contour (Fig 1). If the endocardial contours are still unclear, lateral or total gain control is adjusted to improve image resolution. The tracing of a region of interest is then drawn manually. Within this region of interest, integration of the edge-detected area occurs, which allows measurements of instantaneous area-time relation of the blood-pool area in square centimeters. From these data, stroke area (SA), which is the difference between the maximum end-diastolic area (EDA) and minimum end-systolic area (ESA), is calculated. SA, EDA, and ESA were taken to reflect stroke volume, end-diastolic volume, and end-systolic volume, respectively. The images analyzed from the TEE-ABD were obtained from a transgastric, midventricular, short-axis view by using the LV midpapillary level as an anatomic landmark. The area signal was calibrated at zero on both the ABD and the computer workstation with a predetermined area. These measurements and calculations, along with the pressure measures, were displayed on-line and stored on computer disk for subsequent analysis. An example of the recorded signal is shown in Figure 2. The TEE technique using this border-detection algorithm has been previously validated by us and others, and it has demonstrated a good correlation between LV stroke volume and LV SA in both animal and human studies when different modes were used to measure LV volume and when offline tracing was compared with manual planimetry tracing To further validate the findings of the TEE, two additional patients were subsequently studied separately. In these patients (the validation group) an appropriately sized and calibrated electromagnetic flow probe (Cineflow II; Carolina Medical; King, NC) was placed around the ascending aorta immediately above the coronary artery. Estimations of apneic cardiac output, which were achieved by averaging three thermodilution curves by using 10 ml 5% dextrose solution at 4 C, were used for initial calibration Figure 1. A transgastric, midventricular, short-axis view obtained from TEE with ABD. The LV endocardial blood/tissue interface is shown in red. The region of interest encircles the LV and represents the area analyzed continuously. Shown below the echocardiographic image is the ECG and the LV area signal displayed over time. 178 Clinical Investigations in Critical Care

4 Figure 2. ECG, arterial pressure (Pa), right atrial pressure (Pra), pulmonary artery pressure (Ppa), LV area (LVA), and airway pressure (Paw) recorded over time following apnea in a patient after cardiac bypass surgery during the closed chest condition. to apneic SAP was defined as up. Changes in SAP from the apneic baseline were analyzed in relation to the maximum variation in LV area before and after the positive-pressure breath during each of the four steps. SAP variation, mean LV area measurements, and their variations were compared within each condition by using analysis of variance. Statistical significance was defined as p In an attempt to quantify any additional effect that the positive-pressure breath may have had on subsequent decreases in SAP, we estimated the cumulative SA deficit throughout the breath relative to mean apneic values and correlated this SA deficit with down. The mean apneic SA was taken as the mean SA of the three cardiac cycles preceding the breath, whereas the SA deficit was taken as the sum of each SA minus the mean SA for each cardiac cycle from the start of the breath until the lowest systolic BP occurred. This volume is referred to in the text as the cumulative SA deficit. Data are expressed as mean ( SD). Because the phase relation between positive-pressure ventilation and both SAP and LV area data would be different, depending on which process described above determined the response, we further analyzed the relations between airway pressure, arterial pressure, and LV area by Fourier analysis using the ventilatory cycle as the primary harmonic for three sequential breaths. Furthermore, we examined the effects of positivepressure inspiration and expiration on the matching cardiac cycles to ascertain if single beat changes in EDA, ESA, or SA occurred relative to the ventilatory cycle. In the validation group, TEE-ABD-derived SA and electromagnetic flow probe-derived stroke volume were compared over one complete ventilatory cycle by using simple correlation statistics and the method of least squares. of the electromagnetic flow signal. Integration of the aortic flow signal per beat was used to derive LV stroke volume. Stroke volume changes during ventilation were compared to SA changes to see if TEE-ABD signals accurately tracked LV volume changes. Protocol The protocol sequence consisted of observing the effects of a brief apneic interval (15 to 20 s), followed by performing standard positive-pressure ventilation (tidal volume [Vt], 8 to 10 ml/kg; frequency, 15 breaths/min; fraction of inspired oxygen, 100%) on the dependent measured variables. This apnea-ventilation sequence was repeated three times at each step within the surgical procedure. Data were recorded before and after bypass and during both open and closed chest conditions, thereby yielding four sequential, separate steps. We assumed that the differences between the responses that occurred during closed conditions and the responses that occurred during open chest conditions would reflect the differences in ITP swings during ventilation, whereas the differences between responses that occurred before bypass and responses that occurred after bypass would reflect changes in the contractile state because a bypass induces a transient decrease in contractility. 13 The validation group studies were only performed during open chest conditions. The pericardium was kept closed during the study before and after bypass. Data Analysis Mean apneic steady-state values for all variables were used to define baseline values for each step of the protocol. The maximum decrease in SAP after a positive-pressure breath, as compared to apneic SAP, was defined as down. The maximum increase in SAP during the positive-pressure breath as compared Results In total, 114 apnea/positive-pressure ventilation sequences in 15 patients were collected. The quality of the recorded images on videotapes using the criteria of Schnittger et al 12 was assessed by two observers, each blinded to the interpretation of the other. Only data from sequences accepted by both observers were subjected to further analysis. Based on this screening criteria, 70 of the sequences (61%) were then analyzed. Thirty-six sequences were in open chest conditions, with 18 being recorded before bypass; whereas 34 sequences were in closed chest conditions, with 13 being recorded before bypass. Some subjects had more than one sequence acceptable for a specific condition. In these cases, the individual runs were compared in order to assess the reproducibility of the measurements. Intracondition variability was a 10% maximal difference in LV EDA and a 2.5 maximal difference in SAP during apnea. The first run was chosen for subsequent analysis. Based on this algorithm, we compared the effect of positive-pressure ventilation relative to apnea in 11 subjects during the closed chest condition (5 before bypass) and 14 subjects during the open chest condition (10 before bypass). All subjects remained hemodynamically stable throughout the study protocol, and they were with- CHEST / 116 / 1/ JULY,

5 out the use of IABP counterpulsation or changes in inotropic therapy (Table 1). Effects of Positive-Pressure Ventilation on SAP and LV Area There was an increase or no change in SAP in 22 of the sequences (88%) during positive-pressure inspiration. When SAP increased, the increase in airway and arterial pressure occurred together. If SAP decreased, the decrease occurred during expiration. SAP never increased during expiration. The magnitude of increase or decrease in SAP was similar among subjects (Table 2). Overall, SAP increased by and decreased by mm Hg with inspiration and expiration, respectively. Although SAP tended to vary with the phase of ventilation, no consistent pattern of SA, EDA, or ESA with ventilation could be identified. During positive-pressure inspiration, SA increased in 11 sequences (44%), decreased in 13 sequences (52%), and stayed the same in 1 sequence (4%; mean change, ; Table 3). The EDA increased in 5 sequences (20%), decreased in 19 sequences (76%), and stayed the same in 1 sequence (4%; mean change, ). The ESA increased in 3 sequences (12%), decreased in 19 sequences (76%), and stayed the same in 3 sequences (12%; mean change, ). Furthermore, there was no consistent relation between changes in SAP and changes in SA, EDA, or ESA (Fig 3, left) or between down (Table 2) and changes in SA, EDA, or ESA (Fig 3, right). In most subjects, however, both EDA and ESA decreased during the positive-pressure inspiration (Fig 4), but there was no difference between the degree of decrease in EDA compared with ESA. In the validation group, changes in LV SA were associated with concomitant changes in the electromagnetic flow probe-derived LV stroke volumes during ventilation. Effect of Cardiopulmonary Bypass on SAP and LV Area Relations Before bypass, SAP increased during the positivepressure inspiration in the majority of subjects (93%; Fig 5). During this period (15 sequences), positivepressure ventilation increased the SA in 9 sequences (60%), decreased the SA in 5 sequences (33%) and caused no change in the SA in 1 sequence (7%; mean change, ). The down tended to be greater after bypass, but this did not reach statistical significance. As for the group as a whole, positivepressure inspiration had an inconsistent effect on LV areas: EDA increased in 4 sequences (27%), decreased in 10 sequences (67%), and stayed the same in 1 sequence (7%; mean change, ). ESA had a similar response during positive-pressure inspiration, increasing in 2 sequences (13%), decreasing in 12 sequences (80%), and staying the same in 1 sequence (7%; mean change, ). After cardiopulmonary bypass, the effects of positive-pressure inspiration on SAP were similar to prebypass responses, with SAP increasing in seven sequences (70%) and decreasing in three sequences (30%). In most sequences, however, after cardiopulmonary bypass, SA, EDA, and ESA decreased 80%, 90%, and 70%, respectively, during inspiration, compared with an apneic baseline (p 0.05). Mean apneic EDA was smaller after bypass and demonstrated a greater decrease after a positive-pressure breath than before bypass (p 0.05). Effect of Open and Closed Chest Conditions In both closed and open chest conditions (Fig 6), increases in SAP ( up) occurred in phase with the positive-pressure inspiration (86% open and 82% closed), whereas the down occurred in expiration. The down was greater in the closed than in the open chest condition (Table 2; p 0.05). Changes in SA after positive-pressure ventilation were minimal (mean open chest change, and mean Table 2 Changes in SAP Following a Positive-Pressure Breath* Conditions n % SAP Up Up, % SAP Down Down, All sequences Prebypass Postbypass Open chest Closed chest FAC 30% FAC 30% *Values are expressed as mean SD. % SAP up percentage of maximum SAP during a positive-pressure breath minus SAP during apnea. % SAP down % decrease in SAP during apnea minus minimal SAP during a positive-pressure breath. See Table 1 for expansion of abbreviation. p 0.05 in open vs closed chest. 180 Clinical Investigations in Critical Care

6 Table 3 Changes in Sum SA and LV Area Following a Positive-Pressure Breath* Conditions n Sum SA, Mean SA, SA Change, Mean EDA, EDA Change, Mean ESA, ESA Change, All sequences Prebypass Postbypass Open chest Closed chest FAC 30% FAC 30% *Values are expressed as mean SD. Sum SA sum of each SA minus apneic SA during the positive-pressure breath. See Table 1 for expansion of abbreviation. p 0.05 pre- vs postbypass. p 0.05 open vs closed chest. p 0.05 low vs high FAC. closed chest change, ), and they were not significantly different between open and closed chest conditions, with SA decreasing in 55% of the closed and in 50% of the open chest condition runs. Interestingly, in the closed chest condition, both EDA and ESA decreased during the positive-pressure inspiration in all the sequences, whereas in the open chest condition, this occurred in only 57% of the sequences (p 0.05). Furthermore, EDA and ESA decreased more in the closed compared with the open chest condition (p 0.05). Cumulative SA Deficit and Down There was no measurable relation between the maximal decrease in SAP after a breath and the cumulative SA deficit (summed SA decrease relative to apneic SA; Fig 7). The cumulative SA deficit was higher in the postbypass period, and this was associated with a greater decrease in EDA (p 0.05). The presence of an open or closed chest did not influence this relation. Fourier Analysis A Fourier analysis of the LV area and arterial pressure was done. In the closed chest condition, an Figure 3. Relation between percentage of change in SAP and changes in LV area (left column), and the relation between percentage of absolute decrease in SAP and changes in LV area (right column) during a positive-pressure breath. f SA; F EDA; ΠESA. Figure 4. Relation between the change in EDA and ESA after a positive-pressure breath. CHEST / 116 / 1/ JULY,

7 Figure 5. Relation between percentage change in SAP and changes in LV area during the prebypass (left column) and postbypass (right column) periods. f SA; F EDA; ΠESA. Figure 6. Relation between percent change in SAP and changes in LV area during open chest (left column) and closed chest (right column) conditions. f SA; F EDA; ΠESA. SAP harmonic signal at the same frequency as the airway signal was found in 55% of the runs, whereas it was invariably seen in all of the LV area signals. In the open chest condition, this common harmonic signal was present in only 36% and 64% of the SAP and LV area signals, respectively. However, the phase angles of the SAP and LV area signals relative to the airway signal were different. The airway phase angle slightly preceded the arterial in 80% of the runs by approximately one heartbeat in both the open and closed chest condition, and the two signals had indistinguishable phase angles in 15% of the runs. The airway pressure and the echo area were never in identical phase. In the closed chest condition, the change in the SAP signal preceded the change in the echo area in all cases, with the SAP tending to increase while the echo area was decreasing. In the open chest condition, this occurred 67% of the time. Discussion We observed that changes in SAP during positivepressure ventilation in humans cannot be explained by proportional changes in LV volume. The effects of positive-pressure ventilation on LV volume and SAP are complex and not interpretable by a single mechanism. If SAP increases relative to apneic values during ventilation, it does so during the inspiratory phase, whereas if SAP decreases, it does so during the expiratory phase. These changes in SAP are inconsistently associated with changes in SA, EDA, or ESA, suggesting that coupled changes in LV performance are not primary determinants of SAP variations during ventilation. Although the decrease in SAP after a positive-pressure breath appears to be accentuated during hypovolemic states, 2 the mechanism for these changes does not appear to relate to coupled changes in LV preload. Because the changes in SAP during positive-pressure ventilation are in phase with the change in the airway pressure, we favor the hypothesis that positive-pressure, ventilation-induced changes in SAP may reflect concomitant changes in ITP similar to those in phase 3 of a Valsalva maneuver. Consistent with a direct effect of ITP on SAP variations, the decrease in SAP was more pronounced in the closed (p 0.05) than in the open chest condition for the same Vt. If the observed 182 Clinical Investigations in Critical Care

8 Figure 7. Relation between the fall in SAP expressed as down and the sum of the SA difference (sum SAa SAx for all patients during the open and closed chest condition and for patients with a fractional area of contraction 30% or 30%). decrease in SAP was secondary to a decrease in venous return, then we would expect to see a decrease in SA and EDA. This was not the case. Although SA decreased in 56% of our subjects and EDA decreased in 80% of our subjects (Fig 3), this decrease occurred during the time that SAP was increasing. Furthermore, the relation between the degree of decrease in SAP and the corresponding decrease in SA and EDA (Fig 3) was variable. From the Fourier analysis, we saw that in the closed chest condition, the SAP signal always preceded the change in LV area. These data are consistent with the hypothesis that the increase in ITP from positivepressure ventilation directly alters the SAP. Finally, if the decrease in SAP represents a deficit in LV output secondary to the positive-pressure breath, we would expect that SAP would decrease in proportion to the SA deficit preceding it during the breath. The data show that was also not the case (Fig 7), and it implies that a decrease in SAP during positivepressure ventilation is not necessarily secondary to a decrease in LV stroke volume. Our observations and those from Figure 6 in the study of Abel et al 19 demonstrate less variation in SAP during the open chest condition rather than during the closed chest condition. Based on observations in three subjects, Perel et al 10 and Pizov et al 4 hypothesized that the absence of variation in SAP may indicate the presence of an underlying LV dysfunction during the open chest condition. Neither the data of Abel et al 19 nor ours support this conclusion. Although we saw less SAP variation in our study group following cardiopulmonary bypass, when contractility is reduced, 13 there is a considerable overlap in response between subjects before and after bypass. However, the average apneic EDA in our subjects with variation in SA during a positivepressure breath of 0.5 (n 14) was compared with a mean apneic EDA of only in those subjects (n 11) with 0.5 variation. These data are consistent with results from subjects having a relatively fixed stroke volume, as is commonly seen in patients with heart failure. 13 According to these data, it appears that limiting ITP fluctuations (open chest conditions) minimized the SAP changes seen in response to positive-pressure ventilation, whereas impaired LV function minimizes the changes seen in LV area. This impaired LV function could be secondary to postbypass ischemia, stunning myocardium, or hibernating myocardium. Massumi et al, 3 Jardin et al, 20 and Perel et al 10 suggested that increases in SAP or reversed pulsus paradoxus during a positive-pressure breath would represent an increase in stroke volume either from an increase in preload 6 or a decrease in afterload. 1 A subset of our subjects appears to behave in a fashion similar to that described by these authors. In 10 of our subjects, SA increased during the positive-pressure inspiration, and in all but 1, this increase was in phase with the increase in SAP (Fig 3). In the nine subjects in whom both SAP and SA increased, the increase in SA was associated with an increase in EDA in only three subjects and a decrease in ESA in the remaining six subjects. These data imply that both increasing preload (increase in EDA) and decreasing afterload (decrease in ESA) may be the mechanisms inducing these changes. However, in this subset of our subjects, the reduction in afterload appears to be the more prevalent mechanism responsible for the changes in SAP and LV area. Unfortunately, because many variables can affect the relation between SAP and LV volume, it is still difficult to infer cardiovascular status from changes in SAP. The multiple determinants of SAP variation operating in all patients could explain the variability of findings in both the literature and in our data on this relation. Scharf et al, 21 in their demonstration in an animal model, used intramyocardial radiopaque CHEST / 116 / 1/ JULY,

9 markers to assess sequential volume changes and aortic flow probe data to assess stroke volume, and they found that changes in SAP resulted from a combined interaction between decreases in aortic flow and transmitted increases in ITP. They demonstrated that the aortic flow could decrease as the SAP increased and that this difference was even more pronounced with faster respiratory rates (as seen in their Figure 2). 21 We made similar observations in our validation group study. The disparity in the interpretations of results obtained in these studies could be explained by the varied methods used for measuring LV volume and also by the effects of ventilation on LV area and SAP, which are not measured and recorded on-line. 20,19 In the study of Jardin et al, 20 measurements were also done from a transthoracic approach, as opposed to a transesophageal view, from which image quality is significantly improved. Most of the studies on the effect of positive-pressure ventilation on LV volume and SAP were done in the closed chest condition, except for one in which four subjects had measurements made during the open chest condition. 19 Interestingly, in those open chest subjects, as in our study, minimal variation in SAP occurred during positive-pressure ventilation. Finally, although these workers felt that SAP variations, specifically increases in SAP, reflected a fluid-resuscitated heartfailure state, our data did not support this hypothesis. We saw no differences in the SAP response to positive-pressure ventilation between subjects when referenced either to LV EDA, as a measure of preload, or to fractional area of contraction, as a measure of contractility. Study Limitations Although care was taken to study similar types of subjects undergoing comparable surgical stresses, marked variability in response among subjects occurred. This variation might be a reflection of differing intravascular volume status, as well as differing LV systolic and diastolic function. EDA as an estimate of LV filling volume varied from 3.4 to 26.4 in our patients, although most patients had an EDA around 9.8. Furthermore, we saw that subjects with a larger EDA had less variation in their LV area after a positive-pressure breath. Alteration in diastolic function can also occur after cardiac surgery. 11 The average EDA and pulmonary artery occlusion pressure (Ppao) in our subjects before cardiopulmonary bypass were not significantly different before (EDA, ; Ppao, 14 4mm Hg) and after bypass (EDA, ; Ppao, 12 5 ). We studied similar patients with various levels of cardiac function. All of these patients had coronary artery disease and were undergoing the same type of surgery with open and closed chest conditions. Vasoactive medications were not changed during the protocol. IABP was used transiently in two patients, but it was turned off shortly prior to and during the positive-pressure breath because the arterial pressure waveform would not have been interpretable. Patients with severe left main disease have a prophylactic IABP inserted prior to the operation to prevent decompensation before the bypass, as in our patients. We deliberately chose to evaluate patients with nonhomogeneous cardiac functions because, as stated in the introduction, the goal of our study was to study the effect of positive-pressure ventilation on systolic arterial pressure over a spectrum of cardiac contractility. Because our results seem to reflect a spectrum of responses in LV area to positive-pressure ventilation as opposed to a single mechanism, one could question the validity of our measurements, especially after considering that we accepted only 60% of the data for interpretation, based on our criteria. TEE has limited application during positive-pressure ventilation because the image can shift out of the region of interest. This is why we analyzed only high-quality images after two independent observers using accepted criteria reviewed them. The overall percentage of good-quality images in our study is nevertheless comparable to other studies in which the ABD technique has been used to assess the ventricular area. 14,16,18 Still, issues of the rotational artifact of the LV cavity relative to the TEE, induced by positivepressure breaths, need to be addressed. This rotational artifact can be either lateral or vertical to the plane of the 2D image. In both instances, the area measured by the ABD method may not reflect LV area at the same anatomic location seen during apnea. Lateral movement was clearly seen in several breaths in some of our subjects. In these examples, the ABD measurement moved off the region of interest borders, and these data were rejected. No data with lateral rotational artifacts were used in our analysis. Rotational artifacts were not the only cause for rejecting data. Despite the fact that the TEE probe was not moved during the data acquisition, upward and downward cardiac movement could have been missed because the esophageal position allows for no reference point within the thorax. However, Smith et al 22 addressed this issue previously. They moved the TEE probe 2 cm in and out (4 cm total distance) in the transgastric position from a midpapillary short-axis vein. When they compared measures of EDA and ESA from these three vertical positions, they saw no difference. Because it is highly unlikely that vertical movement of the mediastinal 184 Clinical Investigations in Critical Care

10 block (including esophagus and heart) exceeded 2 cm during a positive-pressure breath, vertical rotational artifacts likely had little influence on our measured values. Furthermore, in two patients in open chest condition, we were able to validate our measurements further by using the electromagnetic flow probe on the aorta. Close correlation was observed between TEE SA and flow probe-derived stroke volume during both ventilation and inferior vena caval occlusion maneuvers. 9 As a final note of validation, Leithner et al 23 demonstrated in normal subjects that lung distention to levels similar to those used in our study reduced LV end-diastolic volume and induced an anterior rotational movement on the heart. They used MRI techniques and thus were limited to end-expiratory analysis as lung volume was progressively increased by the application of 15 cm H 2 O positive endexpiratory pressure. Because the movement they saw did not alter the midventricular short-axis orientation, if TEE had been used in their subjects, TEE would have not seen this movement as a volume artifact. Thus, it seems highly unlikely that our data in this selected population reflect rotational artifacts. The variations that we measured in SAP were small, especially if they were expressed as a percentage. 2 However, we did not limit our analysis to patients in which pulsus paradoxus, defined by a change in SAP 10, was present. Indeed, Rooke et al 24 have shown in a human hemorrhage model that a SAP variation 5mmHgor down 2 indicates minimal intravascular depletion. Their observed changes in SAP following a 500-mL blood removal was (their Table 1). We cannot exclude the possibility that, for larger variations in SAP, changes in ventricular volumes may play a more important role. Our data on closed chest conditions are similar to those obtained by Coriat et al, 25 especially with regard to their Figure 4, which relates the percentage change in EDA with the down. It illustrates how variable the response can be. Two patients had 10% changes in EDA with a down of 5, and two others had EDA changes 40% with a down 5mm Hg. We both observed an average fall in EDA and an increase in down, but there are large individual variations. However, Coriat et al 25 did not record the area measurement simultaneously with the arterial and airway pressure and did not demonstrate that changes in SAP reflect simultaneous changes in LV volume. It has been previously shown that for the same decrease in SAP or pulsus paradoxus occurring during normal inspiration, the aortic flow will decrease when associated with tamponade, but it will remain constant when associated with airway obstruction. 24,26 Consequently, we observed that SAP variation with respiration in the range cannot be explained entirely by changes in LV volume. We saw no difference between changes in EDA vs ESA within each subgroup. Because the absolute value of the end-systolic volume must be less than that of the end-diastolic volume, an equal decrease in both values might be interpreted differently if one used either the absolute volume or a percentage change. We used the absolute value of the area changes in our experiment, as based on previous studies 20,27 to minimize this potentially confounding effect of proportionality. We did not evaluate in our patients the effect of open or closed pericardium. We recorded the hemodynamic parameters when the chest was closed, open before and after bypass during closed pericardial conditions. We did not study the effect of a closed vs open pericardium because the clinical use of our observations, for the most part, is directed toward patients with a closed chest and pericardium. Pericardial constraint is a significant factor in relating positive-pressure ventilation and SAP. Pulsus paradoxus is a typical manifestation of an exaggerated increased pericardial pressure that would reduce venous return. 28 In addition, changes in pericardial pressure will alter the pressure-volume relationship of the left and right ventricles, and systolic performance is augmented by an intact pericardium. 29 Schertz and Pinsky 30 observed, using an animal model, that LV ejection can enhance right ventricular stroke volume, but volume loading or the presence of an intact pericardium did not appreciably alter this interaction. Interestingly, we observed in our study that the presence of an open or closed chest condition did not significantly change SA during a positive-pressure breath (Table 3). Mean airway pressure was not measured; we gave avt, and this raised the peak airway pressure. We did not readjust the Vt during the study in order to keep the same mean airway pressure for each patient. We used a volume-cycled ventilator, not a pressure-cycled ventilator. Because lung compliance can change after a bypass, it is possible that for an identical volume, a variable transpulmonary pressure could be generated. This could alter the change in SAP variation. We preferred to use a defined volume for the simplicity of the test and also because previous studies were done in this fashion. Furthermore, we have previously demonstrated in an intact canine model 31 that if Vt is held constant, then ITP increases by similar amounts, despite markedly changing lung compliance induced by oleic acid infusion. Thus, our ventilatory protocol was more likely to sustain a constant ITP variation across conditions than a protocol in which Vt was varied to CHEST / 116 / 1/ JULY,

11 maintain a common peak airway pressure during positive-pressure ventilation. In summary, the degree of variation in SAP in patients during cardiac surgery cannot be explained by matched changes in LV area, and these results suggest that changes in SAP during ventilation cannot be used solely to assess the determinants of cardiovascular instability. References 1 Pinsky MR, Matuschak GM, Klain M. Determinants of cardiac augmentation by elevations in intrathoracic pressure. J Appl Physiol 1985; 58: Perel A, Pizov R, Cotev S. Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage. Anesthesiology 1987; 67: Massumi RA, Mason DT, Vera Z, et al. Reversed pulsus paradoxus. N Engl J Med 1973; 289: Pizov R, Ya ari Y, Perel A. The arterial pressure waveform during acute ventricular failure and synchronized external chest compression. Anesth Analg 1989; 68: Buda AJ, Pinsky MR, Ingles NB, et al. Effect of intrathoracic pressure on left ventricular performance. N Engl J Med 1979; 301: Brower R, Wise RA, Hassapoyannes C, et al. Effect of lung inflation on lung blood volume and pulmonary venous flow. J Appl Physiol 1985; 58: Taylor RR, Corell JW, Sonnenblick EH, et al. Dependence of ventricular distensibility on filling the opposite ventricle. Am J Physiol 1967; 213: Nishimura RA, Tajik AJ. The Valsalva maneuver and response revisited. Mayo Clin Proc 1986; 61: Robertson D, Stevens RM, Friesinger GC, et al. The effect of Valsalva maneuver on echocardiographic dimensions in man. Circulation 1977; 55: Perel A, Koman V, Geva D, et al. The systolic pressure variation may unmask acute left ventricular ischemic dysfunction upon weaning from cardiopulmonary bypass [abstract]. Anesthesiology 1990; 73:A Humphrey LS, Topol EJ, Rosenfeld GI. Immediate enhancement of left ventricular relaxation by coronary artery bypass grafting: intraoperative assessment. Circulation 1988; 77: Schnittger I, Fitzgerald PJ, Daughters GT, et al. Limitations of comparing left ventricular volumes by two-dimensional echocardiography, myocardial markers and cineangiography. Am J Cardiol 1982; 50: Gorcsan J, Gasior T, Mandarino WA, et al. Assessment of the immediate effects of cardiopulmonary bypass on LV performance by on-line pressure-area relations. Circulation 1994; 89: Pérez JE, Waggoner AD, Barzilai B, et al. On-line assessment of ventricular function by automatic boundary detection and ultrasonic backscatter imaging. J Am Coll Cardiol 1992; 19: Gorcsan J, Morita S, Mandarino WA, et al. Two-dimensional echocardiographic automated border detection accurately reflects changes in left ventricular volume. J Am Soc Echocardiogr 1993; 6: Cahalan MK, Ionescu P, Melton HE, et al. Automated real-time analysis of intraoperative transesophageal echocardiograms. Anesthesiology 1993; 78: Gorcsan J, Lazar J, Romand JA, et al. On-line estimation of stroke volume by means of echocardiographic automated border detection in the canine left ventricle. Am Heart J 1993; 125: Vandenberg BF, Rath LS, Stuhlmuller P, et al. Estimation of left ventricular cavity area with an on-line, semiautomated echocardiographic edge detection system. Circulation 1992; 86: Abel JG, Salerno TA, Panos A, et al. Cardiovascular effects of positive pressure ventilation in humans. Ann Thorac Surg 1987; 43: Jardin F, Farcot JC, Gueret P, et al. Cyclic changes in arterial pulse during respiratory support. Circulation 1983; 68: Scharf SM, Brown R, Saunders N, et al. Hemodynamic effects of positive-pressure inflation. J Appl Physiol 1980; 49: Smith JS, Cahalan MK, Benefiel DJ, et al. Intraoperative detection of myocardial ischemia in high-risk patients: electrocardiographic versus two-dimensional transesophageal echocardiography. Circulation 1985; 72: Leithner C, Podolsky A, Globits S, et al. Magnetic resonance imaging of the heart during positive end-expiratory pressure ventilation in normal subjects. Crit Care Med 1994; 22: Rooke GA, Schwid HA, Shapira Y. The effect of graded hemorrhage and intravascular volume replacement on systolic pressure variation in humans during mechanical and spontaneous ventilation. Anesth Analg 1995; 80: Coriat P, Vrillon M, Perel A, et al. A comparison of systolic blood pressure variations and echocardiographic estimates of end-diastolic left ventricular size in patients after aortic surgery. Anesth Analg 1994; 78: Shabetai R, Fowler NO, Gueron M. The effect of respiration on aortic pressure and flow. Am Heart J 1963; 65: Jardin F, Farcot JC, Gueret P, et al. Echocardiographic evaluation of ventricles during continuous positive airway pressure. J Appl Physiol 1984; 56: Shabetai R, Fowler NO, Fenton JC, et al. Pulsus paradoxus. J Clin Invest 1965; 44: Janicki JS, Weber KT. The pericardium and ventricular interaction, distensibility, and function. Am J Physiol 1980; 238:H494 H Schertz C, Pinsky MR. Effect of the pericardium on systolic ventricular interdependence in the dog. J Crit Care 1993; 8: Romand JA, Shi W, Pinsky MR. Cardiopulmonary effects of positive pressure ventilation during acute lung injury. Chest 1995; 108: Clinical Investigations in Critical Care

Review Article. Interactive Physiology in Critical Illness : Pulmonary and Cardiovascular Systems. Introduction

Review Article. Interactive Physiology in Critical Illness : Pulmonary and Cardiovascular Systems. Introduction 310 Indian Deepak J Physiol Shrivastava Pharmacol 2016; 60(4) : 310 314 Indian J Physiol Pharmacol 2016; 60(4) Review Article Interactive Physiology in Critical Illness : Pulmonary and Cardiovascular Systems

More information

Recent advances in the clinical application of heart-lung interactions Michael R. Pinsky, MD

Recent advances in the clinical application of heart-lung interactions Michael R. Pinsky, MD Recent advances in the clinical application of heart-lung interactions Michael R. Pinsky, MD Clinical applications of heart-lung interactions have centered on the impact of ventilation on regional blood

More information

UPMC Critical Care

UPMC Critical Care UPMC Critical Care www.ccm.pitt.edu Cardiovascular insufficiency with Initiation and Withdrawal of Mechanical Ventilation Michael R. Pinsky, MD, Dr hc Department of Critical Care Medicine University of

More information

Index. K Knobology, TTE artifact, image resolution, ultrasound, 14

Index. K Knobology, TTE artifact, image resolution, ultrasound, 14 A Acute aortic regurgitation (AR), 124 128 Acute aortic syndrome (AAS) classic aortic dissection diagnosis, 251 263 evolutive patterns, 253 255 pathology, 250 251 classifications, 247 248 incomplete aortic

More information

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the Edwards PreSep oximetry catheter

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the Edwards PreSep oximetry catheter 1 2 The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the Edwards PreSep oximetry catheter for continuous central venous oximetry (ScvO2) 3

More information

suggested by Katz and Gauchat (3) for the ex- diaphragm during inspiration, traction is applied Dornhorst, Howard, and Leathart (2), using an

suggested by Katz and Gauchat (3) for the ex- diaphragm during inspiration, traction is applied Dornhorst, Howard, and Leathart (2), using an Journal of Clinical Investigation Vol. 42, No. 2, 1963 THE MECHANISM OF PULSUS PARADOXUS DURING ACUTE PERICARDIAL TAMPONADE * By RICHARD J. GOLINKO,t NEVILLE KAPLAN, AND ABRAHAM M. RUDOLPH t (From the

More information

On-line estimation of left ventricular stroke volume using transoesophageal echocardiography and acoustic quantification

On-line estimation of left ventricular stroke volume using transoesophageal echocardiography and acoustic quantification British Journal of Anaesthesia 1996;77:365 369 On-line estimation of left ventricular stroke volume using transoesophageal echocardiography and acoustic quantification C.-A. GREIM, N. ROEWER, G. LAUX AND

More information

Intra-operative Echocardiography: When to Go Back on Pump

Intra-operative Echocardiography: When to Go Back on Pump Intra-operative Echocardiography: When to Go Back on Pump GREGORIO G. ROGELIO, MD., F.P.C.C. OUTLINE A. Indications for Intraoperative Echocardiography B. Role of Intraoperative Echocardiography C. Criteria

More information

Hemodynamic Monitoring and Circulatory Assist Devices

Hemodynamic Monitoring and Circulatory Assist Devices Hemodynamic Monitoring and Circulatory Assist Devices Speaker: Jana Ogden Learning Unit 2: Hemodynamic Monitoring and Circulatory Assist Devices Hemodynamic monitoring refers to the measurement of pressure,

More information

PROBLEM SET 2. Assigned: February 10, 2004 Due: February 19, 2004

PROBLEM SET 2. Assigned: February 10, 2004 Due: February 19, 2004 Harvard-MIT Division of Health Sciences and Technology HST.542J: Quantitative Physiology: Organ Transport Systems Instructors: Roger Mark and Jose Venegas MASSACHUSETTS INSTITUTE OF TECHNOLOGY Departments

More information

Cardiac Output MCQ. Professor of Cardiovascular Physiology. Cairo University 2007

Cardiac Output MCQ. Professor of Cardiovascular Physiology. Cairo University 2007 Cardiac Output MCQ Abdel Moniem Ibrahim Ahmed, MD Professor of Cardiovascular Physiology Cairo University 2007 90- Guided by Ohm's law when : a- Cardiac output = 5.6 L/min. b- Systolic and diastolic BP

More information

Hemodynamic Monitoring

Hemodynamic Monitoring Perform Procedure And Interpret Results Hemodynamic Monitoring Tracheal Tube Cuff Pressure Dean R. Hess PhD RRT FAARC Hemodynamic Monitoring Cardiac Rate and Rhythm Arterial Blood Pressure Central Venous

More information

(Ann Thorac Surg 2008;85:845 53)

(Ann Thorac Surg 2008;85:845 53) I Made Adi Parmana The utility of intraoperative TEE has become increasingly more evident as anesthesiologists, cardiologists, and surgeons continue to appreciate its potential application as an invaluable

More information

The Use of Dynamic Parameters in Perioperative Fluid Management

The Use of Dynamic Parameters in Perioperative Fluid Management The Use of Dynamic Parameters in Perioperative Fluid Management Gerard R. Manecke Jr., M.D. Chief, Cardiac Anesthesia UCSD Medical Center San Diego, CA, USA Thanks to Tom Higgins, M.D. 1 Goals of today

More information

Mechanical Ventilation & Cardiopulmonary Interactions: Clinical Application in Non- Conventional Circulations. Eric M. Graham, MD

Mechanical Ventilation & Cardiopulmonary Interactions: Clinical Application in Non- Conventional Circulations. Eric M. Graham, MD Mechanical Ventilation & Cardiopulmonary Interactions: Clinical Application in Non- Conventional Circulations Eric M. Graham, MD Background Heart & lungs work to meet oxygen demands Imbalance between supply

More information

Sepsis Wave II Webinar Series. Sepsis Reassessment

Sepsis Wave II Webinar Series. Sepsis Reassessment Sepsis Wave II Webinar Series Sepsis Reassessment Presenters Nova Panebianco, MD Todd Slesinger, MD Fluid Reassessment in Sepsis Todd L. Slesinger, MD, FACEP, FCCM, FCCP, FAAEM Residency Program Director

More information

Coronary Artery Bypass Graft: Monitoring Patients and Detecting Complications

Coronary Artery Bypass Graft: Monitoring Patients and Detecting Complications Coronary Artery Bypass Graft: Monitoring Patients and Detecting Complications Madhav Swaminathan, MD, FASE Professor of Anesthesiology Division of Cardiothoracic Anesthesia & Critical Care Duke University

More information

Relax and Learn At the Farm 2012

Relax and Learn At the Farm 2012 Relax and Learn At the Farm Session 9: Invasive Hemodynamic Assessment and What to Do with the Data Carol Jacobson RN, MN Cardiovascular Nursing Education Associates Function of CV system is to deliver

More information

Arterial Pulse Pressure Variation During Positive Pressure Ventilation and Passive Leg Raising

Arterial Pulse Pressure Variation During Positive Pressure Ventilation and Passive Leg Raising Arterial Pulse Pressure Variation During Positive Pressure Ventilation and Passive Leg Raising J.-L. Teboul, X. Monnet, and C. Richard Introduction Inadequate cardiac preload can play a major role in the

More information

Final October 24, 2001

Final October 24, 2001 American Society of Echocardiography and Society of Cardiovascular Anesthesiologists Task Force Guidelines for Training in Perioperative Echocardiography Introduction and Overview When expertly utilized,

More information

Left atrial function. Aliakbar Arvandi MD

Left atrial function. Aliakbar Arvandi MD In the clinic Left atrial function Abstract The left atrium (LA) is a left posterior cardiac chamber which is located adjacent to the esophagus. It is separated from the right atrium by the inter-atrial

More information

PERICARDIAL DIAESE. Kaijun Cui Associated professor Sichuan University

PERICARDIAL DIAESE. Kaijun Cui Associated professor Sichuan University PERICARDIAL DIAESE Kaijun Cui Associated professor Sichuan University CLASSIFICATION acute pericarditis pericardial effusion cardiac tamponade constrictive pericarditis congenitally absent pericardium

More information

Clinical Commentary. Clinical Usefulness of Respiratory Variations in Arterial Pressure PHYSIOLOGIC BASIS OF THE PHENOMENA.

Clinical Commentary. Clinical Usefulness of Respiratory Variations in Arterial Pressure PHYSIOLOGIC BASIS OF THE PHENOMENA. Clinical Commentary Clinical Usefulness of Respiratory Variations in Arterial Pressure Sheldon Magder Division of Critical Care, McGill University, McGill University Health Centre, Montreal, Quebec There

More information

Echocardiography as a diagnostic and management tool in medical emergencies

Echocardiography as a diagnostic and management tool in medical emergencies Echocardiography as a diagnostic and management tool in medical emergencies Frank van der Heusen MD Department of Anesthesia and perioperative Care UCSF Medical Center Objective of this presentation Indications

More information

When expertly utilized, perioperative echocardiography

When expertly utilized, perioperative echocardiography CARDIOVASCULAR ANESTHESIA SECTION EDITOR KENNETH J. TUMAN SOCIETY OF CARDIOVASCULAR ANESTHESIOLOGISTS American Society of Echocardiography and Society of Cardiovascular Anesthesiologists Task Force Guidelines

More information

CATCH A WAVE.. INTRODUCTION NONINVASIVE HEMODYNAMIC MONITORING 4/12/2018

CATCH A WAVE.. INTRODUCTION NONINVASIVE HEMODYNAMIC MONITORING 4/12/2018 WAVES CATCH A WAVE.. W I S C O N S I N P A R A M E D I C S E M I N A R A P R I L 2 0 1 8 K E R I W Y D N E R K R A U S E R N, C C R N, E M T - P Have you considered that if you don't make waves, nobody

More information

Effect of physiological heart rate changes on left ventricular dimensions and mitral blood flow velocities in the normal fetus

Effect of physiological heart rate changes on left ventricular dimensions and mitral blood flow velocities in the normal fetus ELSEVIER Early Human Development 40 (1995) 109-114 Effect of physiological heart rate changes on left ventricular dimensions and mitral blood flow velocities in the normal fetus P.B. Tsyvian a, K.V. Malkin

More information

Normal Pericardial Physiology

Normal Pericardial Physiology Normal Pericardial Physiology Normal pericardium contains 20-30 ml of lymphoid fluid lubricating function that facilitates normal myocardial rotation and translation during each cardiac cycle in that the

More information

Advanced Multi-Layer Speckle Strain Permits Transmural Myocardial Function Analysis in Health and Disease:

Advanced Multi-Layer Speckle Strain Permits Transmural Myocardial Function Analysis in Health and Disease: Advanced Multi-Layer Speckle Strain Permits Transmural Myocardial Function Analysis in Health and Disease: Clinical Case Examples Jeffrey C. Hill, BS, RDCS Echocardiography Laboratory, University of Massachusetts

More information

Velocity Vector Imaging as a new approach for cardiac magnetic resonance: Comparison with echocardiography

Velocity Vector Imaging as a new approach for cardiac magnetic resonance: Comparison with echocardiography Velocity Vector Imaging as a new approach for cardiac magnetic resonance: Comparison with echocardiography Toshinari Onishi 1, Samir K. Saha 2, Daniel Ludwig 1, Erik B. Schelbert 1, David Schwartzman 1,

More information

PHYSIOLOGY MeQ'S (Morgan) All the following statements related to blood volume are correct except for: 5 A. Blood volume is about 5 litres. B.

PHYSIOLOGY MeQ'S (Morgan) All the following statements related to blood volume are correct except for: 5 A. Blood volume is about 5 litres. B. PHYSIOLOGY MeQ'S (Morgan) Chapter 5 All the following statements related to capillary Starling's forces are correct except for: 1 A. Hydrostatic pressure at arterial end is greater than at venous end.

More information

Georgios C. Bompotis Cardiologist, Director of Cardiological Department, Papageorgiou Hospital,

Georgios C. Bompotis Cardiologist, Director of Cardiological Department, Papageorgiou Hospital, Georgios C. Bompotis Cardiologist, Director of Cardiological Department, Papageorgiou Hospital, Disclosure Statement of Financial Interest I, Georgios Bompotis DO NOT have a financial interest/arrangement

More information

Section 6 Intra Aortic Balloon Pump

Section 6 Intra Aortic Balloon Pump Section 6 Intra Aortic Balloon Pump The Intra Aortic Balloon Pump (IABP) The balloon is synthetic and is made for single use only. It is threaded into the aorta, usually via a femoral approach. The balloon

More information

Cardiac Output Monitoring - 6

Cardiac Output Monitoring - 6 Cardiac Output Monitoring - 6 How to use Wrexham s Cardiac Output Monitors. Wrexham Maelor Critical Care Version 02.05.16 Introduction Types of Devices: NICOM - Cheetah Oesophageal Doppler +/- Pulse Contour

More information

Cardiovascular Nursing Practice: A Comprehensive Resource Manual and Study Guide for Clinical Nurses 2 nd Edition

Cardiovascular Nursing Practice: A Comprehensive Resource Manual and Study Guide for Clinical Nurses 2 nd Edition Cardiovascular Nursing Practice: A Comprehensive Resource Manual and Study Guide for Clinical Nurses 2 nd Edition Table of Contents Volume 1 Chapter 1: Cardiovascular Anatomy and Physiology Basic Cardiac

More information

Adult Echocardiography Examination Content Outline

Adult Echocardiography Examination Content Outline Adult Echocardiography Examination Content Outline (Outline Summary) # Domain Subdomain Percentage 1 2 3 4 5 Anatomy and Physiology Pathology Clinical Care and Safety Measurement Techniques, Maneuvers,

More information

Hemodynamic monitoring beyond cardiac output

Hemodynamic monitoring beyond cardiac output Hemodynamic monitoring beyond cardiac output Prof Xavier MONNET Medical Intensive Care Unit Bicêtre Hospital Assistance publique Hôpitaux de Paris FRANCE Conflicts of interest Lilly GlaxoSmithKline Pulsion

More information

Transesophageal Echocardiography

Transesophageal Echocardiography N. Kolev, G. Huemer, M. Zimpfer Transesophageal Echocardiography A New Monitoring Technique Springer-Verlag Wien New York Nikolai Kolev, MD, FACC Research Cardiologist Associate in Anesthesia and Consultant

More information

Review Using heart lung interactions to assess fluid responsiveness during mechanical ventilation Frédéric Michard and Jean-Louis Teboul

Review Using heart lung interactions to assess fluid responsiveness during mechanical ventilation Frédéric Michard and Jean-Louis Teboul Review Using heart lung interactions to assess fluid responsiveness during mechanical ventilation Frédéric Michard and Jean-Louis Teboul Université Paris XI, Kremlin Bicêtre, France Received: 21 July 2000

More information

Coronary artery bypass grafting (CABG) without an

Coronary artery bypass grafting (CABG) without an Coronary Artery Bypass Grafting on the Beating Heart Evaluated With Integrated Backscatter Kenichi Imasaka, MD, Shigeki Morita, MD, Ichiro Nagano, MD, Munetaka Masuda, MD, Ryuji Tominaga, MD, and Hisataka

More information

Breakout Session: Transesophageal Echocardiography

Breakout Session: Transesophageal Echocardiography Breakout Session: Transesophageal Echocardiography Doris Ockert, MD Andrew Schroeder, MD University of Wisconsin School of Medicine and Public Health Jutta Novalija, MD, PhD Medical College of Wisconsin

More information

Shape and Movement of the Interatrial Septum Predicts Change in Pulmonary Capillary Wedge Pressure

Shape and Movement of the Interatrial Septum Predicts Change in Pulmonary Capillary Wedge Pressure Shape and Movement of the Interatrial Septum Predicts Change in Pulmonary Capillary Wedge Pressure Colin F. Royse, MBBS, MD, FANZCA, 1 Alistair G. Royse, MD, MBBS, FRACS, 2 Paul F. Soeding, MBBS, FANZCA,

More information

Protocolized Cardiovascular Management Based on Ventricular-arterial Coupling

Protocolized Cardiovascular Management Based on Ventricular-arterial Coupling Protocolized Cardiovascular Management Based on Ventricular-arterial Coupling M. R. Pinsky Introduction Central to the management of any hemodynamically unstable patient is the rapid assessment of the

More information

Research. Relationship of Pericardial to Pleural Pressure During Quiet Respiration and Cardiac Tamponade

Research. Relationship of Pericardial to Pleural Pressure During Quiet Respiration and Cardiac Tamponade Research JUNE VOL. XVI An Official Journal of the American Heart Association 19 NO. Relationship of Pericardial to Pleural Pressure During Quiet Respiration and Cardiac Tamponade M.D., Warren G. Gunrherorh,

More information

Trends In Hemodynamic Monitoring: A Review For Tertiary Care Providers

Trends In Hemodynamic Monitoring: A Review For Tertiary Care Providers ISPUB.COM The Internet Journal of Advanced Nursing Practice Volume 12 Number 1 Trends In Hemodynamic Monitoring: A Review For Tertiary Care Providers M E Zerlan Citation M E Zerlan.. The Internet Journal

More information

Admission of patient CVICU and hemodynamic monitoring

Admission of patient CVICU and hemodynamic monitoring Admission of patient CVICU and hemodynamic monitoring Prepared by: Rami AL-Khatib King Fahad Medical City Pi Prince Salman Heart tcentre CVICU-RN Admission patient to CVICU Introduction All the patients

More information

Right Ventricle. Interaction with the pulmonary circulation. Fellowship Intensive Care Nijmegen

Right Ventricle. Interaction with the pulmonary circulation. Fellowship Intensive Care Nijmegen Right Ventricle Interaction with the pulmonary circulation Fellowship Intensive Care Nijmegen Normal right ventricle PAP 25/10 EF 62 ± 8% Constant low pressure perfusion of the lung Maintain low RA pressure

More information

A NONINVASIVE METHOD FOR CHARACTERIZING VENTRICULAR DIASTOLIC FILLING DYNAMICS

A NONINVASIVE METHOD FOR CHARACTERIZING VENTRICULAR DIASTOLIC FILLING DYNAMICS A NONINVASIVE METHOD FOR CHARACTERIZING VENTRICULAR DIASTOLIC FILLING DYNAMICS R. Mukkamala, R. G. Mark, R. J. Cohen Haard-MIT Division of Health Sciences and Technology, Cambridge, MA, USA Abstract We

More information

Impedance Cardiography (ICG) Method, Technology and Validity

Impedance Cardiography (ICG) Method, Technology and Validity Method, Technology and Validity Hemodynamic Basics Cardiovascular System Cardiac Output (CO) Mean arterial pressure (MAP) Variable resistance (SVR) Aortic valve Left ventricle Elastic arteries / Aorta

More information

Nothing to Disclose. Severe Pulmonary Hypertension

Nothing to Disclose. Severe Pulmonary Hypertension Severe Ronald Pearl, MD, PhD Professor and Chair Department of Anesthesiology Stanford University Rpearl@stanford.edu Nothing to Disclose 65 year old female Elective knee surgery NYHA Class 3 Aortic stenosis

More information

² C Y E N G R E M E ssignac Cardiac Arrest Resuscitation Device uob

² C Y E N G R E M E ssignac Cardiac Arrest Resuscitation Device uob E M E R G E N C Y Boussignac Cardiac Arrest Resuscitation Device ² What is b-card? b-card Boussignac Cardiac Arrest Resuscitation Device has been designed specifically for the treatment of cardiac arrest.

More information

WORKSHEET for Evidence-Based Review of Science for Veterinary CPCR

WORKSHEET for Evidence-Based Review of Science for Veterinary CPCR RECOVER 2011 1 of 6 WORKSHEET for Evidence-Based Review of Science for Veterinary CPCR 1. Basic Demographics Worksheet author(s) Kate Hopper Mailing address: Dept Vet Surgical & Radiological Sciences Room

More information

General Cardiovascular Magnetic Resonance Imaging

General Cardiovascular Magnetic Resonance Imaging 2 General Cardiovascular Magnetic Resonance Imaging 19 Peter G. Danias, Cardiovascular MRI: 150 Multiple-Choice Questions and Answers Humana Press 2008 20 Cardiovascular MRI: 150 Multiple-Choice Questions

More information

Background: Bedside ultrasound is emerging as a useful tool in the assessment of

Background: Bedside ultrasound is emerging as a useful tool in the assessment of Abstract: Background: Bedside ultrasound is emerging as a useful tool in the assessment of intravascular volume status by examining measurements of the inferior vena cava (IVC). Many previous studies do

More information

SUPPLEMENTAL MATERIAL

SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL Supplemental methods Pericardium In several studies, it has been shown that the pericardium significantly modulates ventricular interaction. 1-4 Since ventricular interaction has

More information

Constrictive Pericarditis in the Modern Era

Constrictive Pericarditis in the Modern Era Journal of the American College of Cardiology Vol. 51, No. 3, 2008 2008 by the American College of Cardiology Foundation ISSN 0735-1097/08/$34.00 Published by Elsevier Inc. doi:10.1016/j.jacc.2007.09.039

More information

Point-of-Care Ultrasound Closer look at the Inferior Vena Cavae &

Point-of-Care Ultrasound Closer look at the Inferior Vena Cavae & Point-of-Care Ultrasound Closer look at the Inferior Vena Cavae & Brief Introduction to Gross Systolic Function Omar S. Darwish, MS, DO Certified in Point-of-Care Ultrasound Hospitalist University of California,

More information

Assessing Preload Responsiveness Using Arterial Pressure Based Technologies. Patricia A. Meehan, RN, MS Education Consultant Edwards Lifesciences, LLC

Assessing Preload Responsiveness Using Arterial Pressure Based Technologies. Patricia A. Meehan, RN, MS Education Consultant Edwards Lifesciences, LLC Assessing Preload Responsiveness Using Arterial Pressure Based Technologies Patricia A. Meehan, RN, MS Education Consultant Edwards Lifesciences, LLC Content Description : Fluid administration is a first

More information

Interesting Cases - A Case Report: Renal Cell Carcinoma With Tumor Mass In IVC And Heart. O Wenker, L Chaloupka, R Joswiak, D Thakar, C Wood, G Walsh

Interesting Cases - A Case Report: Renal Cell Carcinoma With Tumor Mass In IVC And Heart. O Wenker, L Chaloupka, R Joswiak, D Thakar, C Wood, G Walsh ISPUB.COM The Internet Journal of Thoracic and Cardiovascular Surgery Volume 3 Number 2 Interesting Cases - A Case Report: Renal Cell Carcinoma With Tumor Mass In IVC And Heart O Wenker, L Chaloupka, R

More information

Pericardial Diseases. Smonporn Boonyaratavej, MD. Division of Cardiology, Department of Medicine Chulalongkorn University

Pericardial Diseases. Smonporn Boonyaratavej, MD. Division of Cardiology, Department of Medicine Chulalongkorn University Pericardial Diseases Smonporn Boonyaratavej, MD Division of Cardiology, Department of Medicine Chulalongkorn University Cardiac Center, King Chulalongkorn Memorial Hospital 21 AUGUST 2016 Pericardial

More information

Rationale for Prophylactic Support During Percutaneous Coronary Intervention

Rationale for Prophylactic Support During Percutaneous Coronary Intervention Rationale for Prophylactic Support During Percutaneous Coronary Intervention Navin K. Kapur, MD, FACC, FSCAI Assistant Director, Interventional Cardiology Director, Interventional Research Laboratories

More information

Respiratory Physiology and the Impact of Different Modes of Ventilation on the Photoplethysmographic Waveform

Respiratory Physiology and the Impact of Different Modes of Ventilation on the Photoplethysmographic Waveform Sensors 2012, 12, 2236-2254; doi:10.3390/s120202236 Review OPEN ACCESS sensors ISSN 1424-8220 www.mdpi.com/journal/sensors Respiratory Physiology and the Impact of Different Modes of Ventilation on the

More information

Adel Hasanin Ahmed 1

Adel Hasanin Ahmed 1 Adel Hasanin Ahmed 1 PERICARDIAL DISEASE The pericardial effusion ends anteriorly to the descending aorta and is best visualised in the PLAX. PSAX is actually very useful sometimes for looking at posterior

More information

Handling Common Problems & Pitfalls During. Oxygen desaturation in patients receiving mechanical ventilation ACUTE SEVERE RESPIRATORY FAILURE

Handling Common Problems & Pitfalls During. Oxygen desaturation in patients receiving mechanical ventilation ACUTE SEVERE RESPIRATORY FAILURE Handling Common Problems & Pitfalls During ACUTE SEVERE RESPIRATORY FAILURE Pravit Jetanachai, MD QSNICH Oxygen desaturation in patients receiving mechanical ventilation Causes of oxygen desaturation 1.

More information

SymBioSys Exercise 2 Cardiac Function Revised and reformatted by C. S. Tritt, Ph.D. Last updated March 20, 2006

SymBioSys Exercise 2 Cardiac Function Revised and reformatted by C. S. Tritt, Ph.D. Last updated March 20, 2006 SymBioSys Exercise 2 Cardiac Function Revised and reformatted by C. S. Tritt, Ph.D. Last updated March 20, 2006 The goal of this exercise to explore the behavior of the heart as a mechanical pump. For

More information

Mechanics of Cath Lab Support Devices

Mechanics of Cath Lab Support Devices Mechanics of Cath Lab Support Devices Issam D. Moussa, MD Professor of Medicine Mayo Clinic College of Medicine Chair, Division of Cardiovascular Diseases Mayo Clinic Jacksonville, Florida DISCLOSURE Presenter:

More information

Citation Acta medica Nagasakiensia. 1984, 29

Citation Acta medica Nagasakiensia. 1984, 29 NAOSITE: Nagasaki University's Ac Title Author(s) Efficacy of Coenzyme Q10 Administra Aortic Stenosis and Pacemaker Induc Igarashi, Katsuro Citation Acta medica Nagasakiensia. 1984, 29 Issue Date 1984-10-25

More information

Learning Objectives. Denver Health Medical Center. Nothing to Disclose... Advanced Topics in Anesthesia

Learning Objectives. Denver Health Medical Center. Nothing to Disclose... Advanced Topics in Anesthesia Nothing to Disclose... Learning Objectives 1. Describe which clinical situations are appropriate for TEE monitoring in noncardiac surgery including indications / contraindications for TEE placement. 2.

More information

Shock, Monitoring Invasive Vs. Non Invasive

Shock, Monitoring Invasive Vs. Non Invasive Shock, Monitoring Invasive Vs. Non Invasive Paula Ferrada MD Assistant Professor Trauma, Critical Care and Emergency Surgery Virginia Commonwealth University Shock Fluid Pressors Ionotrope Intervention

More information

Global left ventricular circumferential strain is a marker for both systolic and diastolic myocardial function

Global left ventricular circumferential strain is a marker for both systolic and diastolic myocardial function Global left ventricular circumferential strain is a marker for both systolic and diastolic myocardial function Toshinari Onishi 1, Samir K. Saha 2, Daniel Ludwig 1, Erik B. Schelbert 1, David Schwartzman

More information

MASSACHUSETTS INSTITUTE OF TECHNOLOGY

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Harvard-MIT Division of Health Sciences and Technology HST.542J: Quantitative Physiology: Organ Transport Systems Instructors: Roger Mark and Jose Venegas MASSACHUSETTS INSTITUTE OF TECHNOLOGY Departments

More information

Mechanism of Pulsus Paradoxus in Clinical Shock *

Mechanism of Pulsus Paradoxus in Clinical Shock * The Journal of Clinical Investigatton Vol. 46, No. 11, 1967 Mechanism of Pulsus Paradoxus in Clinical Shock * JAY N. COHN,$ ALAN L. PINKERSON, AND FELIX E. TRISTANI (From the Medical Service, Veterans

More information

Outline. Echocardiographic Assessment of Pericardial Effusion/Tamponade: The Essentials

Outline. Echocardiographic Assessment of Pericardial Effusion/Tamponade: The Essentials Echocardiographic Assessment of Pericardial Effusion/Tamponade: The Essentials John R Schairer DO FACC Henry Ford Heart and Vascular Institute No Disclosures Outline Normal Anatomy and Physiology Pathophysiology

More information

The Cardiac Cycle Clive M. Baumgarten, Ph.D.

The Cardiac Cycle Clive M. Baumgarten, Ph.D. The Cardiac Cycle Clive M. Baumgarten, Ph.D. OBJECTIVES: 1. Describe periods comprising cardiac cycle and events within each period 2. Describe the temporal relationships between pressure, blood flow,

More information

Disclaimer. Improving MET-based patient care using treatment algorithms. Michael R. Pinsky, MD, Dr hc. Different Environments Demand Different Rules

Disclaimer. Improving MET-based patient care using treatment algorithms. Michael R. Pinsky, MD, Dr hc. Different Environments Demand Different Rules Michael R. Pinsky, MD - June 29, 26 Improving MET-based patient care using Michael R. Pinsky, MD, Dr hc Department of Critical Care Medicine University of Pittsburgh Disclaimer Michael R. Pinsky, MD is

More information

Automated Assessment of Ventricular Volume and Function by Echocardiography: Validation of Automated Border Detection

Automated Assessment of Ventricular Volume and Function by Echocardiography: Validation of Automated Border Detection ORIGINAL ARTICLES Automated Assessment of Ventricular Volume and Function by Echocardiography: Validation of Automated Border Detection Richard L. Morrissey, MD, Samuel C. Siu, MD,]. Luis Guerrero, BS,

More information

Uncommon Doppler Echocardiographic Findings of Severe Pulmonic Insufficiency

Uncommon Doppler Echocardiographic Findings of Severe Pulmonic Insufficiency Uncommon Doppler Echocardiographic Findings of Severe Pulmonic Insufficiency Rahul R. Jhaveri, MD, Muhamed Saric, MD, PhD, FASE, and Itzhak Kronzon, MD, FASE, New York, New York Background: Two-dimensional

More information

Mechanics of Cath Lab Support Devices

Mechanics of Cath Lab Support Devices Mechanics of Cath Lab Support Devices Issam D. Moussa, MD Chief Medical Officer First Coast Cardiovascular Institute, Jacksonville, FL Professor of Medicine, UCF, Orlando, FL None DISCLOSURE Percutaneous

More information

Copyright 2017 American College of Emergency Physicians. All rights reserved.

Copyright 2017 American College of Emergency Physicians. All rights reserved. POLICY Approved April 2017 Guidelines for the Use of Transesophageal Echocardiography (TEE) in the ED for Cardiac Arrest Approved by the ACEP Board of Directors April 2017 1. Introduction The American

More information

Technique. Technique. Technique. Monitoring 1. Local anesthetic? Aseptic technique Hyper-extend (if radial)

Technique. Technique. Technique. Monitoring 1. Local anesthetic? Aseptic technique Hyper-extend (if radial) Critical Care Monitoring Hemodynamic Monitoring Arterial Blood Pressure Cannulate artery Uses 2 Technique Sites Locate artery, prep 3 1 Technique Local anesthetic? Aseptic technique Hyper-extend (if radial)

More information

CARDIOLOGY AND CARDIOVASCULAR ANESTHESIA

CARDIOLOGY AND CARDIOVASCULAR ANESTHESIA CARDIOLOGY AND CARDIOVASCULAR ANESTHESIA STANFORD UNIVERSITY HOSPITAL Perioperative Echocardiography Educational Program and Clinical Services Program Goals I. Provide Cardiovascular Anesthesia fellows

More information

Using Ventilator and Cardiovascular Graphics in the Patient Who Is Hemodynamically Unstable

Using Ventilator and Cardiovascular Graphics in the Patient Who Is Hemodynamically Unstable Using Ventilator and Cardiovascular Graphics in the Patient Who Is Hemodynamically Unstable Bryant A Murphy MD and Charles G Durbin Jr MD FAARC Introduction Venous Return and Intrathoracic Pressure Variation

More information

stroke volume in cardiac tamponade

stroke volume in cardiac tamponade British Heart journal, 1970, 32, 592-596. Effect of respiration on venous return and stroke volume in cardiac tamponade I. T. Gabe, D. T. Mason, J. H. Gault, J. Ross, Jr., R. Zelis, C. J. Mills, E. Braunwald,

More information

The potential value of increasing negative intrathoracic

The potential value of increasing negative intrathoracic Optimizing Standard Cardiopulmonary Resuscitation With an Inspiratory Impedance Threshold Valve* Keith G. Lurie, MD; Katherine A. Mulligan, BA; Scott McKnite, BS; Barry Detloff, BA; Paul Lindstrom, BS;

More information

37 1 The Circulatory System

37 1 The Circulatory System H T H E E A R T 37 1 The Circulatory System The circulatory system and respiratory system work together to supply cells with the nutrients and oxygen they need to stay alive. a) The respiratory system:

More information

Cardiac Physiology an Overview

Cardiac Physiology an Overview Cardiac Physiology an Overview Dr L J Solomon Department of Paediatrics and Child Health School of Medicine Faculty of Health Sciences University of the Free State and PICU Universitas Academic Hospital

More information

-12. -Ensherah Mokheemer - ABDULLAH ZREQAT. -Faisal Mohammad. 1 P a g e

-12. -Ensherah Mokheemer - ABDULLAH ZREQAT. -Faisal Mohammad. 1 P a g e -12 -Ensherah Mokheemer - ABDULLAH ZREQAT -Faisal Mohammad 1 P a g e In the previous lecture we talked about: - cardiac index: we use the cardiac index to compare the cardiac output between different individuals,

More information

Evaluation of Left Ventricular Diastolic Dysfunction by Doppler and 2D Speckle-tracking Imaging in Patients with Primary Pulmonary Hypertension

Evaluation of Left Ventricular Diastolic Dysfunction by Doppler and 2D Speckle-tracking Imaging in Patients with Primary Pulmonary Hypertension ESC Congress 2011.No 85975 Evaluation of Left Ventricular Diastolic Dysfunction by Doppler and 2D Speckle-tracking Imaging in Patients with Primary Pulmonary Hypertension Second Department of Internal

More information

Topics to be Covered. Cardiac Measurements. Distribution of Blood Volume. Distribution of Pulmonary Ventilation & Blood Flow

Topics to be Covered. Cardiac Measurements. Distribution of Blood Volume. Distribution of Pulmonary Ventilation & Blood Flow Topics to be Covered MODULE F HEMODYNAMIC MONITORING Cardiac Output Determinants of Stroke Volume Hemodynamic Measurements Pulmonary Artery Catheterization Control of Blood Pressure Heart Failure Cardiac

More information

TEE Outside of the Cardiac OR

TEE Outside of the Cardiac OR TEE Outside of the Cardiac OR STEVE GIBSON MD PHD OU DEPARTMENT OF ANESTHEIOLOGY I have no financial relationships or conflicts of interest to disclose TRANSESOPHAGEAL ECHOCARDIOGRAPHY Basic principles

More information

Left Ventricular End-Diastolic Pressure in Evaluating Left Ventricular Function

Left Ventricular End-Diastolic Pressure in Evaluating Left Ventricular Function Clin. Cardiol. 4,28-33 (1981) 0 G. Witzstrock Publishing House, nc. Practitioner s Corner Left Ventricular End-Diastolic Pressure in Evaluating Left Ventricular Function A. s. SKANDRAN, M.D., B. L. SEGAL,

More information

Tailored Volume Resuscitation in the Critically Ill is Achievable. Objectives. Clinical Case 2/16/2018

Tailored Volume Resuscitation in the Critically Ill is Achievable. Objectives. Clinical Case 2/16/2018 Tailored Volume Resuscitation in the Critically Ill is Achievable Heath E Latham, MD Associate Professor Fellowship Program Director Pulmonary and Critical Care Objectives Describe the goal of resuscitation

More information

Determination of Stroke Volume from Left Ventricular Isovolumetric Contraction and Ejection Times

Determination of Stroke Volume from Left Ventricular Isovolumetric Contraction and Ejection Times Determination of Stroke Volume from Left Ventricular Isovolumetric Contraction and Ejection Times Clarence M. AGRESS, M.D. and Stanley WEGNER SUMMARY Examination was made of the relationship of left ventricular

More information

Chapter 9, Part 2. Cardiocirculatory Adjustments to Exercise

Chapter 9, Part 2. Cardiocirculatory Adjustments to Exercise Chapter 9, Part 2 Cardiocirculatory Adjustments to Exercise Electrical Activity of the Heart Contraction of the heart depends on electrical stimulation of the myocardium Impulse is initiated in the right

More information

Cigna - Prior Authorization Procedure List Cardiology

Cigna - Prior Authorization Procedure List Cardiology Cigna - Prior Authorization Procedure List Cardiology Category CPT Code CPT Code Description 33206 Insertion of new or replacement of permanent pacemaker with transvenous electrode(s); atrial 33207 Insertion

More information

Hemodynamic Assessment. Assessment of Systolic Function Doppler Hemodynamics

Hemodynamic Assessment. Assessment of Systolic Function Doppler Hemodynamics Hemodynamic Assessment Matt M. Umland, RDCS, FASE Aurora Medical Group Milwaukee, WI Assessment of Systolic Function Doppler Hemodynamics Stroke Volume Cardiac Output Cardiac Index Tei Index/Index of myocardial

More information

Cardiology. Objectives. Chapter

Cardiology. Objectives. Chapter 1:44 M age 1121 Chapter Cardiology Objectives art 1: Cardiovascular natomy and hysiology, ECG Monitoring, and Dysrhythmia nalysis (begins on p. 1127) fter reading art 1 of this chapter, you should be able

More information

University of Florida Department of Surgery. CardioThoracic Surgery VA Learning Objectives

University of Florida Department of Surgery. CardioThoracic Surgery VA Learning Objectives University of Florida Department of Surgery CardioThoracic Surgery VA Learning Objectives This service performs coronary revascularization, valve replacement and lung cancer resections. There are 2 faculty

More information

QUIZ 1. Tuesday, March 2, 2004

QUIZ 1. Tuesday, March 2, 2004 Harvard-MIT Division of Health Sciences and Technology HST.542J: Quantitative Physiology: Organ Transport Systems Instructors: Roger Mark and Jose Venegas MASSACHUSETTS INSTITUTE OF TECHNOLOGY Departments

More information

Introduction to Chest Radiography

Introduction to Chest Radiography Introduction to Chest Radiography RSTH 366: DIAGNOSTIC TECHNIQUES Alan Alipoon BS, RCP, RRT Instructor Department of Cardiopulmonary Sciences 1 Introduction Discovered in 1895 by Wilhelm Roentgen Terminology

More information