1 MEDICAL CORPORATION 5206 Asbury Rd., P.O. Box 758, Farmingdale, NJ USA Fax

2 MYO/WIRE Temporary Cardiac Pacing Wire System MYO/WIRE temporary cardiac pacing wires. MYO/KLIP connectors to protect the exposed proximal end of the temporary pacing wire. MEDICAL CORPORATION

3 MYO/WIRE Temporary Cardiac Pacing Wires SMOOTH INSULATION A single layer of extruded insulation provides the smoothest coating used among cardiac pacing wires. This reduces tissue trauma on insertion and removal. MULTIFILAMENT STAINLESS STEEL WIRE Forty-nine braided strands of 316 stainless steel wire provide excellent flexibility, strength, conductivity and corrosion resistance. This flexible construction assists in atraumatic implantation and removal of wire from the patient. COLOR CODING OF WIRE INSULATION Choice of three wire insulation colors: orange, light orange and white. coding can assist the hospital personnel in the identification of implanted wires. CUSTOM KITS Up to four pacing wires can be packaged into a single sterile pouch at no premium in price to meet the specific needs of surgeons in your hospital (minimum 10 box order). INTERRUPTED ELECTRODE STYLES Two styles, M-25 and M-26, have 13.0mm 2 of electrode surface exposed two inches from the curved needle to permit complete implantation of bare wire in the myocardium. This reduces the possibility of ionization and the need to adjust threshold levels post-operatively. SNAP OFF KEITH NEEDLE Sharp Keith needle is easily broken off at the groove in the shaft thereby eliminating the need to cut the needle with wire cutters. Epicardial Electrodes Intramyocardial Electrodes Cat. No. 020-### M-20 Styles. One inch of bare wire which can be bent into desired configuration by surgeon. Cat. No. 024-### M-24 Styles. Two and one half inches of bare wire exposed immediately adjacent to the curved needle. Cat. No. 021-### M-21 Styles. One eighth inch diameter bare wire loop can be secured onto myocardium with non-tied continuous suture through wire loop and myocardium. Suture unravels during removal. Cut wire loop to permit removal if suture is tied around loop and myocardium. Cat. No. 025-### M-25 Styles. is peeled back to form a winged electrode. One centimeter of bare wire provides 13.0mm 2 of exposed electrode surface area which can be totally implanted into the myocardium. Cat. No. 022-### M-22 Styles. Robicsek Atrial Temporary Cardiac Pacing Electrode. Six millimeter diameter bare tapered wire loop. Place suture snug but not tight around neck of electrode. Loop will compress through suture upon removal. Cat. No. 026-### M-26 Styles. One centimeter of bare wire provides 13.0mm 2 of electrode surface area which can be totally implanted into the myocardium. is tapered at the electrode to facilitate insertion and removal. ###Last three digits identify needle and color options. See ordering information.

4 INDIFFERENT LEAD An eight inch ground or indifferent electrode is designed to be implanted in subcutaneous tissue. A special curved cutting needle permits this subcutaneous electrode placement. This electrode can eliminate the need for an indifferent electrode in the heart. Available in 8 and 24 lengths. Cat. No MYO/KLIP Connection System The MYO/KLIP connector provides a closed system from the myocardium to the pacing equipment. These connectors: 1. Protect the proximal end of the temporary pacing wire from body fluids, 2. Electrically insulate the electrode connector, 3. Provide a reliable and convenient connector to the MYO/LEAD. Sealing Plug U.S. Patent 4,442,840 Connector Body MYO/WIRE Snap-off Needle Locking End Cap Cat. Nos (sterile) (non-sterile) MYO/KLIP Assembly Instructions 1. Snap off the Keith needle by gripping the needle on either side of the groove and bending it with a brisk motion. Discard the sharp portion of the needle. 2. Insert the needle shank portion into the aperture at the back end of the connector body as far as it will go. Bend the protruding wire at right angles as shown above. MYO/LEAD Extension Cord The MYO/LEAD cable accepts the MYO/KLIP connector at one end and plugs into the pacing equipment on the other. It allows monitoring and pacing equipment to be located in a remote position. To connect the electrode to the pacing equipment, simply remove the sealing plug and insert the connector into the MYO/LEAD cable. This cable is available in 6 lengths with choice of two temporary pacing unit connectors. 3. Lock the end cap into position by forcing the tabs up against the back end of the connector body and aligning them with the corresponding grooves in the connector body. Force the two pieces together so that the locking tabs spread outward then pop into place. The end is now hermetically sealed. 4. Insert the sealing plug into the open end of the connector body to hermetically seal it when the connector is not in use.

5 MYO/WIRE Temporary Cardiac Pacing Wire System Ordering Information M-20 Style Box of 24 Description: Epicardial MYO/WIRE Temporary Cardiac Pacing Wire. One inch of bare wire at the cardiac end. Length: 61cm, Size 2-0. Actual Size Style has no curved needle options. Lt. Lt * * * * * M-21 Style Box of 24 Actual Size Description: Epicardial MYO/WIRE Temporary Cardiac Pacing Wire. One eighth inch diameter bare wire loop at the cardiac end. Length: 61cm, Size 2-0. Lt. Lt. Style has no curved needle options * * * * * M-22 Style Box of 24 Actual Size Description: Robicsek Atrial Temporary Cardiac Pacing Electrode. One quarter inch diameter tapered bare wire loop at the cardiac end. Length: 61cm, Size 2-0. Lt. Lt. Style has no curved needle options * * * *Non-stock product. Available as custom order product in minimum 10 box quantities.

6 MYO/WIRE Temporary Cardiac Pacing Wire System Ordering Information M-24 Style Box of 24 Taper Point Curved Needle Options Description: Intramyocardial MYO/WIRE Temporary Cardiac Pacing Wire. Two and one half inches of bare wire exposed immediately adjacent to curved needle. Length: 61cm, Size mm 16mm 3/8 Circle 17mm Lt * * * * * * * * Lt * * * * * * * * * * * M-25 Style Box of 24 Taper Point Curved Needle Options Description: Intramyocardial MYO/WIRE Temporary Cardiac Pacing Wire. is laid away to form a winged electrode with 13.0mm 2 of exposed electrode surface area. Length: 61cm, Size mm 16mm 3/8 Circle Lt * * * Lt * * * * * * * * * *Non-stock product. Available as custom order product in minimum 10 box quantities.

7 MYO/WIRE Temporary Cardiac Pacing Wire System Ordering Information M-26 Style Box of 24 Taper Point Curved Needle Options Description: Intramyocardial MYO/WIRE Temporary Cardiac Pacing Wire. One half inch of bare wire provides 13.0mm 2 of exposed electrode surface area. Length: 61cm, Size mm 16mm 3/8 Circle 17mm Lt * * * * * * * * * * * Lt * * * * * * * * * * * * Indifferent Leads, 8 Box of 24 Taper Cutting Taper Point Description: Eight inch ground or indifferent electrode. Special curved cutting needle permits subcutaneous placement of electrode. Length: 20cm, Size mm Straight Electrode 1.0mm Diameter x 22mm Length Lt * * * * Indifferent Leads, 24 Box of 24 Taper Cutting Description: Twenty-four inch ground or indifferent electrode. Special curved cutting needle permits subcutaneous placement of electrode. Length: 61cm, Size 2-0. Electrode 1.0mm Diameter x 22mm Length *Non-stock product. Available as custom order product in minimum 10 box quantities. Lt * *

8 MYO/WIRE Temporary Cardiac Pacing Wire System Ordering Information MYO/KLIP Box Description: MYO/KLIP connector protects exposed distal end of temporary pacing wire. MYO/KLIP Sterile, 12/Box MYO/KLIP Non-Sterile, 120/Box MYO/LEAD Each Description: MYO/LEAD cable accepts MYO/KLIP connector at one end and plugs into temporary pacing unit at other end. MYO/LEAD 6 Cable MYO/LEAD Description: MYO/LEAD cable accepts MYO/KLIP connector at one end and plugs into temporary pacing unit at other end. (Medtronic 5348 and 5388) MYO/LEAD 6 Cable 2001 A&E Medical Corporation AE/0101/5M

Single Use Curlew TM Multiple Biopsy Forceps

Single Use Curlew TM Multiple Biopsy Forceps Single Use Curlew TM Multiple Biopsy Forceps 13 SPECIMEN WITH METAL STORAGE CYLINDER With In Situ Fixation, Batch or Single Specimen Collection US Patents 5,782,747; 5,980,468; 6,071,248; foreign patents

More information

Percutaneous Leads. Directions for Use Content: REV A

Percutaneous Leads. Directions for Use Content: REV A Percutaneous Leads Directions for Use CAUTION: Federal law restricts this device to sale, distribution and use by or on the order of a physician. 91078744-07 Content: 92190387 REV A Guarantees Boston Scientific

More information

DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS

DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS HALYARD* MIC* AND MIC-KEY* INTRODUCER KITS HALYARD* MIC* and MIC-KEY* Introducer Kits provide physicians with an innovative solution to facilitate the primary

More information

Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL

Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL Table of Contents Bryan-DUmon Series II rigid bronchoscope 1. 2. 3. 4. 5. Diagram and Overview Universal Barrel Bronchial and

More information

7% - 15% Single Tunnel Repair of Plantar Plate. Savings of. are common with EcoSMART *Patent Pending

7% - 15% Single Tunnel Repair of Plantar Plate. Savings of. are common with EcoSMART *Patent Pending * Provide Value Sterile kit packaging provides high quality, surgical grade instruments and implants making your O.R. more efficient. No hassles or expense from cleaning, storing, sterilizing, and maintaining

More information

Safe-T-Centesis catheter drainage system. Innovations in patient safety, clinician safety and procedural efficacy.

Safe-T-Centesis catheter drainage system. Innovations in patient safety, clinician safety and procedural efficacy. Safe-T-Centesis catheter drainage system Innovations in patient safety, clinician safety and procedural efficacy. Safe-T-Centesis catheter drainage system This innovative drainage system is designed to

More information

DYNAMIC, TRANSVERSE COMPRESSION. Low Profile, Anatomic Design, Type II Anodized. Mechanical Compression Designed to Stimulate the Fusion Process

DYNAMIC, TRANSVERSE COMPRESSION. Low Profile, Anatomic Design, Type II Anodized. Mechanical Compression Designed to Stimulate the Fusion Process CoLink_XP_ST_080218.pdf 1 8/2/18 8:36 AM SURGICAL TECHNIQUE CoLink XP Plates DYNAMIC, TRANSVERSE COMPRESSION C M Y CM MY CY CMY K MTP Std. Plate MTP Revision Plate Lapidus Standard +1mm and +2mm Y Plate

More information

MARKING RING VEIN GRAFT VALVE INSTRUMENTS. Hook, Valve. TFX SURGICAL SPECIALTIES Phone Toll Free: Fax:

MARKING RING VEIN GRAFT VALVE INSTRUMENTS. Hook, Valve. TFX SURGICAL SPECIALTIES Phone Toll Free: Fax: 355838 351785 351749 355175 MARKING RING VEIN GRAFT MARKING RING-VEIN GRAFT The aorta to coronary saphenous vein graft is widely used for the treatment of coronary atherosclerosis. Assessment of the post-operative

More information

Knee spanning solutions

Knee spanning solutions Knee spanning solutions System features Indications Intended to be used on adults or pediatric patients as required for fracture fixation (open or closed); post-traumatic joint contracture which has resulted

More information

Transtibial PCL Reconstruction. Surgical Technique. Transtibial PCL Reconstruction

Transtibial PCL Reconstruction. Surgical Technique. Transtibial PCL Reconstruction Transtibial PCL Reconstruction Surgical Technique Transtibial PCL Reconstruction The Arthrex Transtibial PCL Reconstruction System includes unique safety features for protecting posterior neurovascular

More information

Implanting an Adult Rat with the Single-Channel Epoch Transmitter for Recording Electrocardiogram in the Type II electrode configuration.

Implanting an Adult Rat with the Single-Channel Epoch Transmitter for Recording Electrocardiogram in the Type II electrode configuration. Implanting an Adult Rat with the Single-Channel Epoch Transmitter for Recording Electrocardiogram in the Type II electrode configuration. Recommended Surgical Tools A. Scalpel handle B. Scalpel blade (#15)

More information

CABLE GRIP SYSTEM COMPREHENSIVE CABLE GRIP SYSTEM. Family Ties

CABLE GRIP SYSTEM COMPREHENSIVE CABLE GRIP SYSTEM. Family Ties CABLE GRIP SYSTEM COMPREHENSIVE CABLE GRIP SYSTEM Family Ties Contoured for Optimal Fit with Proximal Femur The GTR cradles the bone anatomically while the strategically placed proximal and distal fins

More information

Zenith Alpha T HORACIC ENDOVASCULAR GRAFT

Zenith Alpha T HORACIC ENDOVASCULAR GRAFT Device description Zenith Alpha T HORACIC ENDOVASCULAR GRAFT www.cookmedical.com AI-D21181-EN-F Modular design The two-piece modular system allows the physician to customize a graft system to fit each

More information

4766 Research Dr. San Antonio, TX insightdentalsystems.com

4766 Research Dr. San Antonio, TX insightdentalsystems.com OVERVIEW OF THE INSIGHT DENTAL IMPLANT DELIVERY SYSTEM The IDS system comes in a unit dose implant system where its advantage provides sterile instrumentation in one single-use kit. It is organized to

More information

Technique Guide KISSloc Suture System

Technique Guide KISSloc Suture System Technique Guide KISSloc Suture System The KISSloc Suture System consists of a strong self-cinching suture assembly, a unique load-dispersing Arrow Plate and procedure specific instrumentation. Simple,

More information

Acute Therapy Systems. provencare Catheter Sets

Acute Therapy Systems. provencare Catheter Sets Acute Therapy Systems provencare Catheter Sets Catheter Sets Contents provencare Catheter Sets 4 provencare Product Features and Accessories 6 provencare Single Lumen Catheter Sets 8 provencare Paediatric

More information

INNOVATIVE PRODUCTS G, J AND GJ-TUBES WITH ENFit TM CONNECTION

INNOVATIVE PRODUCTS G, J AND GJ-TUBES WITH ENFit TM CONNECTION MIC * & MIC-KEY * Enterostomy Tubes INNOVATIVE PRODUCTS G, J AND GJ-TUBES WITH ENFit TM CONNECTION DIGESTIVE HEALTH PRODUCT CATALOGUE INNOVATIVE PRODUCTS - G, J AND GJ-TUBES WITH ENFit TM CONNECTION DIGESTIVE

More information

Pinit Plate Small Bone Fusion System Bone Plate & Screw System

Pinit Plate Small Bone Fusion System Bone Plate & Screw System Pinit Plate Small Bone Fusion System Bone Plate & Screw System Description The Pinit Plate Small Bone Fusion System consists of 2-hole bone plates made available in three length options and two thickness

More information

Adult Cannulae. product catalog

Adult Cannulae. product catalog Adult Cannulae product catalog cardiac cardiac surgery solutions Table of Contents Arterial Cannulae 4 Curved Tip Aortic Arch Cannulae 4 Straight Tip Aortic Arch Cannulae 11 Flexible Aortic Arch Cannulae

More information

Surgical Technique. 3.5mm and 4.5mm Lateral Proximal Tibia Locking Plates

Surgical Technique. 3.5mm and 4.5mm Lateral Proximal Tibia Locking Plates Surgical Technique 3.5mm and 4.5mm Lateral Proximal Tibia Locking Plates PERI-LOC Periarticular Locked Plating System 3.5mm and 4.5mm Lateral Proximal Tibia Locking Plate Surgical Technique Contents Product

More information

Surgical Technique. Distal Radius and Foot

Surgical Technique. Distal Radius and Foot Surgical Technique Distal Radius and Foot JET-X BAR Unilateral Fixator Distal Radius and Foot Surgical Technique Contents Design Features...2 Distal Radius Surgical Technique Indications...10 Surgical

More information

Bio-TransFix ACL Reconstruction. Surgical Technique

Bio-TransFix ACL Reconstruction. Surgical Technique Bio-TransFix ACL Reconstruction Surgical Technique Bio-TransFix ACL Reconstruction 1 Semitendinosus and gracilis tendon autografts or tibialis tendon allografts are mounted on the GraftPro workstation.

More information

Surgical Technique. Anterolateral and Medial Distal Tibia Locking Plates

Surgical Technique. Anterolateral and Medial Distal Tibia Locking Plates Surgical Technique Anterolateral and Medial Distal Tibia Locking Plates PERI-LOC Periarticular Locked Plating System Anterolateral and Medial Distal Tibia Locking Plates Surgical Technique Contents Product

More information

MULTIPOLAR BIPOLAR CUP. Surgical Technique

MULTIPOLAR BIPOLAR CUP. Surgical Technique MULTIPOLAR BIPOLAR CUP Surgical Technique MULTIPOLAR BIPOLAR CUP ASSEMBLY 1PREASSEMBLY (BACK TABLE) TECHNIQUE INSERT FEMORAL HEAD Seat the femoral head securely in the polyethylene liner. The inner split

More information

CrossTIE. PIP Arthrodesis Implant. surgical technique ordering information PEEK IMPLANTS PEEK IMPLANTS ALLOGRAFT IMPLANTS CROSSTIE INSERTER

CrossTIE. PIP Arthrodesis Implant. surgical technique ordering information PEEK IMPLANTS PEEK IMPLANTS ALLOGRAFT IMPLANTS CROSSTIE INSERTER ordering information x x 0o 1443-3301 1444-3300 x x 10o 1443-3311 1444-3310 2.5mm x 2.5mm x 0o 1443-2501 1444-2500 2.5mm x 2.5mm x 10o 1443-2511 1444-2510 ALLOGRAFT IMPLANTS * Sterile Packaged in Saline,

More information

Versatility and Proven Safety

Versatility and Proven Safety Versatility and Proven Safety Indicated for: Temporary or Permanent placement Standard or Over-The-Wire Delivery Jugular, Femoral, Antecubital, and Popliteal Access > Proven Safety Initial Clinical Trial

More information

Set-up Instructions. MANUFACTURED BY COMMUNICATIONS-APPLIED TECHNOLOGY CO., INC. RESTON, VA. CAGE CODE: 0EEY2

Set-up Instructions. MANUFACTURED BY COMMUNICATIONS-APPLIED TECHNOLOGY CO., INC. RESTON, VA. CAGE CODE: 0EEY2 Set-up Instructions C-AT Level A/B Radio Interface with: Push-to-Talk Assembly, Shaped Audio Throat Microphone Bi-aural Speaker Assembly (two configurations) MANUFACTURED BY COMMUNICATIONS-APPLIED TECHNOLOGY

More information

Ligation. Port Systems. Other Solutions. New and Upcoming. Instrumentation. Suction & Irrigation. Retrieval Systems

Ligation. Port Systems. Other Solutions. New and Upcoming. Instrumentation. Suction & Irrigation. Retrieval Systems Product Catalog Port Systems Natura 2 GeniLook 3 GeniPalm 4 GeniShield Hasson 6 GeniPort 7 GeniFirst 8 Cannula 9 Instrumentation GeniSurge 11 NanoSurge 3mm 13 Ligation GeniClip Open Applier 21 GeniClip

More information

SURGICAL TECHNIQUE. SECURIS Pedicle Screw System for Minimally Invasive Surgery. 2 I SECURIS Pedicle Screw System

SURGICAL TECHNIQUE. SECURIS Pedicle Screw System for Minimally Invasive Surgery. 2 I SECURIS Pedicle Screw System Surgical Technique e Guide SECURIS Pedicle Screw System for Minimally Invasive Surgery Securis Pedicle Screw System has been engineered to provide temporary posterior stabilization of the thoracolumbar

More information

Technique Guide Hammertoe Correction System

Technique Guide Hammertoe Correction System Technique Guide Hammertoe Correction System TM The ToeMATE Hammertoe Correction System is an easy to implant bone screw system intended for the correction of hammertoe deformity. It is provided in a complete

More information

Visit Linvatec.com today to learn more. Surgical Technique: Sequential Meniscal Running Stitch

Visit Linvatec.com today to learn more. Surgical Technique: Sequential Meniscal Running Stitch ORDERING INFORMATION Sequent Meniscal Repair System MR004S MR007S MR004C MR007C SC047D Straight Needle, 4 Implants Straight Needle, 7 Implants Curved Needle, 4 Implants Curved Needle, 7 implants Sequent

More information

Merete BLP. Surgical Technique. - Bunion Locking Plate - Low Profile Locking Bone Plate System

Merete BLP. Surgical Technique. - Bunion Locking Plate - Low Profile Locking Bone Plate System Merete BLP - Bunion Locking Plate - Low Profile Locking Bone Plate System Surgical Technique Merete Medical, Inc. 49 Purchase Street Rye, N.Y. 10580 Phone: 914 967-1532 www.merete-medical.com - Surgical

More information

Technique Guide. *smith&nephew MAGNUM 2 Knotless Implant

Technique Guide. *smith&nephew MAGNUM 2 Knotless Implant Technique Guide *smith&nephew MAGNUM 2 Knotless Implant MAGNUM 2 knotless implant The MAGNUM 2 implant increases surgeon control by combining independent cortical bone lock, suture lock, and incremental

More information

ErgoSys Ergonomics to perfection

ErgoSys Ergonomics to perfection ErgoSys Ergonomics to perfection Laparoscopic instruments 2 ErgoSys Ergonomic, economic and precise The modern handle system for maximum precision PAJUNK ErgoSys sets new standards in laparoscopy in terms

More information

Surgical Technique. Proximal Humerus Locking Plate

Surgical Technique. Proximal Humerus Locking Plate Surgical Technique Proximal Humerus Locking Plate PERI-LOC Upper Extremity Locked Plating System 3.5mm & 4.5mm Proximal Humerus Locking PlatesCatalog Infor Table of Contents Introduction.........................................................2

More information

Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter

Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter Caution: Federal (USA) law restricts this device to sale by or on the order of a physician. DEVICE DESCRIPTION

More information

MICS & FEMORAL CANNULAE

MICS & FEMORAL CANNULAE MICS & FEMORAL CANNULAE Cannulae that can High performance cannulae for direct and femoral cannulation, either in conventional or minimally invasive cardiac surgery 1. Pfeiffer et al. Interactive Cardiovascular

More information

Technique Guide Small Bone Fusion System

Technique Guide Small Bone Fusion System Technique Guide Small Bone Fusion System The Pinit Plate Small Bone Fusion System is a super low profile, modular bone plate and screw system designed to stabilize a bunionectomy with a medial to lateral

More information

Correction System. Surgical Technique

Correction System. Surgical Technique Nextra Hammertoe Correction System Surgical Technique Maximized Bone Purchase* Stable and Secure Phalanx Optimized Screw Design Adjustable Bone-to-Bone Apposition Progressive Ratchet Tightening Mechanism

More information

New Dimensions in Medical Technology

New Dimensions in Medical Technology New Dimensions in Medical Technology MEDIONICS INTERNATIONAL INC. Table of Contents Adult Tenckhoff... pg. 1 Paediatric Tenckhoff... pg. 2 Neonatal Tenckhoff... pg. 2 Adult Coil... pg. 3 Paediatric Coil...

More information

Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family

Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family MICRO-INTRODUCERS Micro-Introducer Kits Galt s Micro-Introducer Kits with smooth transition,

More information

Simply Complete. VA-LCP Elbow Plating System.

Simply Complete. VA-LCP Elbow Plating System. Simply Complete. VA-LCP Elbow Plating System. Building on success Founded upon the established principles of Synthes LCP technology and the first generation elbow plates, the Variable Angle LCP Elbow Plating

More information

Home Health Foundation, Inc. To create more permanent IV access for patients undergoing long term IV therapy.

Home Health Foundation, Inc. To create more permanent IV access for patients undergoing long term IV therapy. PROCEDURE ORIGINAL DATE: 06/99 Revised Date: 09/02 Home Health Foundation, Inc. SUBJECT: PURPOSE: MIDLINE CATHETER INSERTION To create more permanent IV access for patients undergoing long term IV therapy.

More information

Восток-пром CATALOGUE INSEMINATION & IN VITRO FERTILIZATION КАТАЛОГ ИНСЕМИНАЦИЯ & РЕПРОДУКТИВНАЯ МЕДИЦИНА. медикал

Восток-пром CATALOGUE INSEMINATION & IN VITRO FERTILIZATION КАТАЛОГ ИНСЕМИНАЦИЯ & РЕПРОДУКТИВНАЯ МЕДИЦИНА. медикал CATALOGUE INSEMINATION & IN VITRO FERTILIZATION КАТАЛОГ ИНСЕМИНАЦИЯ & РЕПРОДУКТИВНАЯ МЕДИЦИНА Central HQ Karadžičová St. Nb 8-A 82108 Bratislava - SLOVAKIA Phone/Fax Land-line: +421 (0) 2 5939 6000 Fax:

More information

Overview. The Team Concept. Chapter 7. Assisting the ALS Provider 9/11/2012. The Team Concept ALS Procedures and Equipment

Overview. The Team Concept. Chapter 7. Assisting the ALS Provider 9/11/2012. The Team Concept ALS Procedures and Equipment Chapter 7 Assisting the ALS Provider Slide 1 Overview The Team Concept ALS Procedures and Equipment Electrocardiogram (ECG) Monitoring Slide 2 The Team Concept Prehospital care involves many individuals

More information

RD180 SP TECHNOLOGY GUIDE READ THIS PRODUCT INSERT THOROUGHLY BEFORE USE

RD180 SP TECHNOLOGY GUIDE READ THIS PRODUCT INSERT THOROUGHLY BEFORE USE RD180 SP TECHNOLOGY GUIDE READ THIS PRODUCT INSERT THOROUGHLY BEFORE USE FIG. 1 RD180 SP - THE RUNNING DEVICE 1 2 6 3 7 4 5 1 NEEDLE 2 FERRULE 3 SUTURE 4 DEVICE TIP 5 ANGLED SHAFT 6 HANDLE 7 PINK LEVER

More information

The Ceterix NovoStitch Disposable Suture Passer. Do Not Reuse

The Ceterix NovoStitch Disposable Suture Passer. Do Not Reuse The Ceterix NovoStitch Disposable Suture Passer Ceterix Orthopaedics 959 Hamilton Avenue Menlo Park, CA 94025 Customer Service: (650) 241-1748 IK Sterile D Do Not Reuse i See Instructions for Use THE CETERIX

More information

OSS Modular Arthrodesis System. Assembly Guide

OSS Modular Arthrodesis System. Assembly Guide OSS Modular Arthrodesis System Assembly Guide One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized care to one patient. The science and art of medical

More information

QUICK REFERENCE GUIDE. The PreFix Fixator (92000 Series) ALWAYS INNOVATING

QUICK REFERENCE GUIDE. The PreFix Fixator (92000 Series) ALWAYS INNOVATING 21 The PreFix Fixator (92000 Series) ALWAYS INNOVATING INTRODUCTION The PreFix fixator is designed to provide temporary external fixation. This may be needed when local facilities or the condition of the

More information

Part 1: General requirements

Part 1: General requirements Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 10555-1 Second edition 2013-06-15 Corrected version 2014-01-15 Intravascular catheters Sterile and single-use catheters Part 1: General requirements

More information

INSTRUCTIONS FOR USE AND CARE

INSTRUCTIONS FOR USE AND CARE DIAMONDS INSTRUCTIONS FOR USE AND CARE DIAMONDS, MULTI-USE, FRICTION GRIP Quala Diamonds are a rotary cutting device made of stainless steel and coated with diamond particles on the working end. It is

More information

Implantation Procedure

Implantation Procedure VNS Therapy System For Healthcare Professionals October 2010 Worldwide Version Caution: U.S. federal law restricts this device to sale by or on the order of a physician. 2011 0344 Note: This is one part

More information

LMH. Minimal Bone Resection. Lesser Metatarsal Head Implant. Thin, low-profile design for minimal bone resection

LMH. Minimal Bone Resection. Lesser Metatarsal Head Implant.   Thin, low-profile design for minimal bone resection Minimal Bone Resection LMH Lesser Metatarsal Head Implant Thin, low-profile design for minimal bone resection Stem offset dorsally for anatomically correct alignment in medullary canal Rectangular shape

More information

MULTIFIX S Knotless Implants

MULTIFIX S Knotless Implants Technique Guide MULTIFIX S Knotless Implants The MULTIFIX S system offers 5.5mm and 6.5mm knotless, all-peek, poundin implants. The system provides multiple fixation options, a streamlined technique, and

More information

Retrieval Systems. Port Systems. Ligation. Other Solutions. Instrumentation. New and Upcoming. Suction & Irrigation

Retrieval Systems. Port Systems. Ligation. Other Solutions. Instrumentation. New and Upcoming. Suction & Irrigation Product Catalog Port Systems Natura 2 GeniLook 3 GeniPalm 4 GeniShield Hasson 6 GeniPort 7 GeniFirst Cannula 9 Instrumentation GeniSurge 11 NanoSurge 13 BiSurge 1 Suction & Irrigation GeniFlow 17 Aquas

More information

Instructions for Use. IJ Catheter Ultrasound Model Version 2400 Series

Instructions for Use. IJ Catheter Ultrasound Model Version 2400 Series Instructions for Use IJ Catheter Ultrasound Model Version 2400 Series 3601 Sagamore Parkway North, Suite B Lafayette, IN 47904 Phone 765.742.4813 www.hemocleanse.com Instructions Revision 3.0 2014 Table

More information

Document No. BMB/IFU/40 Rev No. & Date 00 & 15/11/2017 Issue No & Date 01 & 15/11/2017

Document No. BMB/IFU/40 Rev No. & Date 00 & 15/11/2017 Issue No & Date 01 & 15/11/2017 Central Venous Catheter Device Description Multi-lumen catheters incorporate separate, non-communicating vascular access lumens within a single catheter body. Minipunctur Access Sets And Trays: Used for

More information

Surgical Leads. Directions for Use. CAUTION: Federal law restricts this device to sale, distribution and use by or on the order of a physician.

Surgical Leads. Directions for Use. CAUTION: Federal law restricts this device to sale, distribution and use by or on the order of a physician. Surgical Leads Directions for Use CAUTION: Federal law restricts this device to sale, distribution and use by or on the order of a physician. 91078747-08 Content: 92190987 REV A Guarantees Boston Scientific

More information

Surgical procedure. METS Modular Proximal Femur

Surgical procedure. METS Modular Proximal Femur Surgical procedure METS Modular Proximal Femur Surgical Procedure Contents 1.0 2.0 3.0 4.0 5.0 Device information 2 3 1.1 Product overview 1.2 Indications 1.3 Absolute contra-indications 1.4 Relative

More information

CONVENTIONAL ADULT CANNULAE

CONVENTIONAL ADULT CANNULAE CONVENTIONAL ADULT CANNULAE Cannulae that can Comprehensive portfolio of aortic, venous and cardioplegia cannulae, vents, suction wands and sumps 1. Assmann et al. Artificial Organs 214; 39(3): 23-211

More information

CONVENTIONAL ADULT CANNULAE

CONVENTIONAL ADULT CANNULAE CONVENTIONAL ADULT CANNULAE Cannulae that can Comprehensive portfolio of aortic, venous and cardioplegia cannulae, vents, suction wands and sumps CONVENTIONAL ADULT CANNULAE Conventional Adult Cannulae

More information

Cannula Portfolio NEW

Cannula Portfolio NEW NEW Cannula Portfolio Part of CONMED s Shoulder Restoration System. For arthroscopic shoulder procedures, CONMED has a diverse portfolio of unique cannulas in multiple sizes, materials, and thread designs

More information

Technique Guide Lapidus Arthrodesis System

Technique Guide Lapidus Arthrodesis System Technique Guide Lapidus Arthrodesis System HVA Angle IMA Angle The AlignMate Lapidus Arthrodesis System features low-profile, anatomically pre-contoured Bone Plates with either a combination of locking

More information

MPJ Implant System. Patents Pending Worldwide

MPJ Implant System. Patents Pending Worldwide MPJ Implant System Patents Pending Worldwide OVERVIEW ACTIVE STABILIZATION The DynaFORCE Active Stabilization System is the first to offer a hybrid implant system designed to address the most common rearfoot,

More information

Imbibe Bone marrow aspiration needle. Operative technique

Imbibe Bone marrow aspiration needle. Operative technique Imbibe Bone marrow aspiration needle Operative technique Imbibe Bone Marrow Aspiration Needle Imbibe Bone marrow aspiration needle Contents 1. Smart design... 3 2. Operative technique... 4 Posterior iliac

More information

A U X I L I A R Y C O N N E C T O R S Surgical Technique

A U X I L I A R Y C O N N E C T O R S Surgical Technique A U X I L I A R Y C O N N E C T O R S Surgical Technique AUXILIARY CONNECTORS ISSYS LP Auxiliary Connectors The ISSYS LP auxiliary connectors were designed to provide medial-lateral variability for the

More information

System. Humeral Nail. Surgical Technique

System. Humeral Nail. Surgical Technique System Humeral Nail Surgical Technique Contents IMPLANT FEATURES 2 1. INDICATIONS 3 2. PRE-OPERATIVE PLANNING 3 3. PATIENT POSITIONING & FRACTURE REDUCTION 3 4. INCISION 4 5. ENTRY POINT 4-6 6. PROXIMAL

More information

3.5 mm Locking Attachment Plate

3.5 mm Locking Attachment Plate For Treatment of Periprosthetic Fractures 3.5 mm Locking Attachment Plate Surgical Technique Table of Contents Introduction 3.5 mm Locking Attachment Plate 2 Indications 4 Surgical Technique Preparation

More information

Correction System. Surgical Technique

Correction System. Surgical Technique Nextra Hammertoe Correction System Surgical Technique Maximized Bone Purchase* Stable and Secure Phalanx Optimized Screw Design Adjustable Bone-to-Bone Apposition Progressive Ratchet Tightening Mechanism

More information

OPTIONAL/ADDITIONAL INSTRUMENTS

OPTIONAL/ADDITIONAL INSTRUMENTS 20 Elevated 6320-36-22 20 Elevated Rim Liner, 36mm OD x 22mm ID 6320-80-22 20 Elevated Rim Liner, 80mm OD x 22mm ID 6320-42-26 20 Elevated Rim Liner, 42mm OD x 26mm ID 6320-80-26 20 Elevated Rim Liner,

More information

Maximize Safety in Trendelenburg

Maximize Safety in Trendelenburg Pink Pad XL Maximize Safety in Trendelenburg Prevents Patient Sliding The advanced material of the Pink Pad molds and conforms to greatly enhance patient safety, ensuring better surgical outcomes. Eliminating

More information

REAL NON-STICK BIPOLAR FORCEPS & MICRO MONOPOLAR FORCEPS

REAL NON-STICK BIPOLAR FORCEPS & MICRO MONOPOLAR FORCEPS NOBLE REAL NON-STICK BIPOLAR FORCEPS & MICRO MONOPOLAR FORCEPS Now Available With Irrigation! The key to the Noble Metal s Non-Stick property is that the energy is moved to and from the distal tips and

More information

Petite Wound Drainage System. 13mm CWV Drainage System. CWSump. CWV with Trocar

Petite Wound Drainage System. 13mm CWV Drainage System. CWSump. CWV with Trocar CWVDrain Designed to assure optimum cosmetic results Tapered, hubless design provides atraumatic insertion and removal Internal ribs prevent collapsing or kinking Large 150cc capacity reservoir decreases

More information

Technique Guide. 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system.

Technique Guide. 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system. Technique Guide 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system. Table of Contents Introduction 3.5 mm LCP Proximal Humerus Plate 2 AO Principles

More information

FS MTS. Micro Periodontal Tissue Scissors

FS MTS. Micro Periodontal Tissue Scissors FEATHERLITE SCISSORS Our patented Flex Series Scissors are designed to have a 300% increase in its shearing angulation compared to conventional scissors. The result is that, no mater what is being cut,

More information

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13 Contents IMPLANT FEATURES 2 1. INDICATIONS 3 2. PRE-OPERATIVE PLANNING 3 3. PATIENT POSITIONING & FRACTURE REDUCTION 3 4. INCISION 4 5. ENTRY POINT 4-6 6. PROXIMAL NAIL INSERTION 6-7 7. PROXIMAL LOCKING

More information

Surgical Technique. Targeter Systems Overview

Surgical Technique. Targeter Systems Overview Surgical Technique Targeter Systems Overview PERI-LOC Locked Plating System Targeter Systems Overview Table of contents Product overview... 2 Introduction... 2 Indications... 2 Design features and benefits...

More information

ompanionport Speciality Medical Devices For The Veterinary Community Surgical Suggestions

ompanionport Speciality Medical Devices For The Veterinary Community Surgical Suggestions Speciality Medical Devices For The Veterinary Community suture holes Place the CompanionPort in the subcutaneous port pocket off to one side so that the septum of the port will not lie directly beneath

More information

(51) Int Cl.: A61B 17/16 ( ) A61B 17/82 ( )

(51) Int Cl.: A61B 17/16 ( ) A61B 17/82 ( ) (19) TEPZZ 8 Z_ B_T (11) EP 2 8 12 B1 (12) EUROPEAN PATENT SPECIFICATION (4) Date of publication and mention of the grant of the patent: 03.08.16 Bulletin 16/31 (21) Application number: 13713282. (22)

More information

fassier DUVal TelescoPIc IM system s RESCUE SYSTEM 2.0

fassier DUVal TelescoPIc IM system s RESCUE SYSTEM 2.0 fassier DUVal TelescoPIc IM system s RESCUE SYSTEM 2.0 The Rescue System was conceived to retrieve components of the Fassier- Duval telescopic IM System after the treatment has been completed or in case

More information

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system.

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system. Technique Guide 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system. Table of Contents Introduction 3.5 mm LCP Olecranon Plates 2 AO Principles 3 Indications 3 Clinical

More information

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation. Technique Guide LCP Small Fragment System Table of Contents Introduction

More information

Integra. ADVANSYS Plating System SURGICAL TECHNIQUE

Integra. ADVANSYS Plating System SURGICAL TECHNIQUE Integra ADVANSYS Plating System SURGICAL TECHNIQUE Table of Contents Dorsal Lisfranc Plate Indications...2 Contraindications...2 Description...2 Surgical Technique...3 Surgical Site Preparation...3 Step

More information

CPT 6 Stainless Steel Primary Hip System

CPT 6 Stainless Steel Primary Hip System CPT 6 Stainless Steel Primary Hip System Surgical Technique The proven, simple solution 1Osteotomy of the Femoral Neck Superimpose the Osteotomy Guide on the proximal femur. Position the guide over the

More information

ACL Reconstruction with Flipped BTB Graft Surgical Technique

ACL Reconstruction with Flipped BTB Graft Surgical Technique ACL Reconstruction with Flipped BTB Graft Surgical Technique Flipped BTB Graft "Based on the clinical success of GraftLink soft tissue grafts*, I wanted to develop a technique using the same tensioning

More information

TRUSTED SOLUTIONS FOR SIMPLIFIED PATIENT CARE. Shiley Tracheostomy Product Guide GettyImages

TRUSTED SOLUTIONS FOR SIMPLIFIED PATIENT CARE. Shiley Tracheostomy Product Guide GettyImages TRUSTED SOLUTIONS FOR SIMPLIFIED PATIENT CARE. Shiley Tracheostomy Product Guide GettyImages 503532118 TABLE OF CONTENTS Shiley Flexible Adult Tracheostomy Tubes 3 Shiley Extended-Length Tracheostomy Tubes

More information

Veterinary Products Catalog. I.V. Catheters Needles Syringes Winged Infusion Sets

Veterinary Products Catalog. I.V. Catheters Needles Syringes Winged Infusion Sets Veterinary Products Catalog I.V. Catheters Needles Syringes Winged Infusion Sets Contents SurGuard 3 Safety Hypodermic Needles & Syringes 4 Sur-Vet Surflo ETFE I.V. Catheters 5 SURFLO ETFE I.V. Catheters

More information

COMPARING KIRSCHNER WIRE FIXATION TO A NEW DEVICE USED FOR PROXIMAL INTERPHALANGEAL FUSION

COMPARING KIRSCHNER WIRE FIXATION TO A NEW DEVICE USED FOR PROXIMAL INTERPHALANGEAL FUSION C H A P T E R 3 0 COMPARING KIRSCHNER WIRE FIXATION TO A NEW DEVICE USED FOR PROXIMAL INTERPHALANGEAL FUSION Scott R. Roman, DPM INTRODUCTION The most common fixation for proximal interphalangeal fusion

More information

A Legacy of Serving the Surgical Community

A Legacy of Serving the Surgical Community TM A Legacy of Serving the Surgical Community Step By Step Instructions For over half a century, Stryker has been developing products based on the expressed needs of leading practitioners. Introducing

More information

CLARIVEIN INFUSION CATHETER

CLARIVEIN INFUSION CATHETER CLARIVEIN INFUSION CATHETER General Product Description Overview The ClariVein Infusion Catheter (ClariVein -IC) is an infusion catheter system designed to introduce physician-specified medicaments into

More information

Humeral SuturePlate. Surgical Technique

Humeral SuturePlate. Surgical Technique Humeral SuturePlate Surgical Technique The humeral SuturePlate is an anatomically designed, low profile, titanium polyaxial locking plate and screw system. Multiple chamfered suture eyelets along the margin

More information

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable.

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable. PRODUCT CATALOG Since 1985» Simple. Predictable. Profitable. 2014 IMPLANTS HEALING PLUG INSERTERS COLLAGEN PRODUCTS 3.0mm Well Integra-CP Part No. DIAMETER LENGTH Price 345-306 4.5mm mm $280.00 345-308

More information

3 Hearing Protection Products

3 Hearing Protection Products 3 Hearing Protection Products page 1 of 5 Issue Date 01/01/04 Disposable Ear Plugs 3M TM Foam Ear Plugs 1100 & 1110 Tapered shape to fit the ear canal comfortably Soft foam seals the ear comfortably Smooth,

More information

Quality. Elegance. Innovation.

Quality. Elegance. Innovation. Quality. Elegance. Innovation. Triumph Orthodontic Instruments Quality and engineering come together for superior performance The Triumph Orthodontic Instrument line provides the orthodontic professional

More information

Simply Great Wire! Great prices.

Simply Great Wire! Great prices. 2017 CATALOG Simply Great Wire! Great prices. CONTENTS 2-4 NiTi Wires 5 Stainless Steel Wires 6-7 Archforms 8 Beta Titanium Molybdenum Wires 9 Wire Auxiliaries WWW.HIGHLANDMETALS.COM NiTi Wires SuperElastic

More information

DISCOVER NEW HORIZONS IN FLUID DRAINAGE. Bringing Safety and Convenience to Fluid Drainage Management

DISCOVER NEW HORIZONS IN FLUID DRAINAGE. Bringing Safety and Convenience to Fluid Drainage Management DISCOVER NEW HORIZONS IN FLUID DRAINAGE Bringing Safety and Convenience to Fluid Drainage Management DRAIN ASEPT Pleural and Peritoneal Drainage Catheter System 600mL or 1,000mL Evacuated Drainage Bottle

More information

American Orthodontics americanortho.com (800) The Aarhus System Mini-Implant Screws/TADs Ti6AL4V surgical grade titanium alloy

American Orthodontics americanortho.com (800) The Aarhus System Mini-Implant Screws/TADs Ti6AL4V surgical grade titanium alloy Focus On TADS 3M Oral Care 3m.com/ortho (800) 423-4588 American Orthodontics americanortho.com (800) 558-7687 Comfort Solutions Inc comfortsolutions.ca Dentaurum Inc dentaurum.com (800) 523-3946 Information

More information

Optimize your hemodialysis procedural bundle.

Optimize your hemodialysis procedural bundle. Optimize your hemodialysis procedural bundle. Cook Turbo-Flo HD ACUTE HEMODIALYSIS CATHETER SETS AND TRAYS Featuring Sof-Flex catheter material for balanced performance and feel. MEDICAL Choose from two

More information

i INTERACTIVE CATALOG FIND YOUR IDEAL CANNULAE

i INTERACTIVE CATALOG FIND YOUR IDEAL CANNULAE i INTERACTIVE CATALOG FIND YOUR IDEAL CANNULAE Catalog 2017 i USER TIPS Easily navigate through the pages in our 2017 Cannula Catalog by using the mini-menu shown on upper right of each page. Navigate

More information

US Patent No. 6,309,396B1. G. David Ritland, M.D.

US Patent No. 6,309,396B1. G. David Ritland, M.D. US Patent No. 6,309,396B1 G. David Ritland, M.D. The Femur Finder is designed to direct the guide wire into the medullary canal. Do not use it to manipulate the fracture fragments, reduce the fracture,

More information