1 Simply Complete. VA-LCP Elbow Plating System.

2 Building on success Founded upon the established principles of Synthes LCP technology and the first generation elbow plates, the Variable Angle LCP Elbow Plating System has the following features: Designed to reduce the risk of soft tissue irritation by taking into account the poor soft tissue coverage of the elbow, thereby improving the plate profile with an anatomical plate contour and enabling the screw heads to sit flush in the plate hole. Offers simplicity and adaptability: variable angle locking technology combines the simplicity of the established LCP screw insertion technique with the possibility of adapting screw angulations. Adaptability is enhanced during screw insertion by offering predefined screw angles while allowing +/-15 off-axis angulation, if needed. Responds to the specifics of proximal ulna fractures by recognizing the particular biomechanical requirements of each fracture type and therefore offering specific implants with optimized shapes and screw configurations. Provides multiple distal humerus plate configurations including parallel and perpendicular plating, allowing surgeons to choose their preferred solution. improving patient care.

3 Designed to reduce the risk of soft tissue irritation Poor soft tissue coverage of the elbow makes the area prone to implant prominence. The VA-LCP Elbow Plating System is designed to help reduce the risk of soft tissue irritation through focused improvements to the implant design and profile. Plate design Contoured metaphyseal plate profile, together with rounded edges and an improved anatomical plate fit help reduce the prominence of the construct without compromising stability. 1 2 Plate-screw interface designed for minimal screw-head prominence 2.7 mm variable angle locking screw: recess for screwhead minimizes screw prominence. 2.7 mm variable angle locking screws give the surgeon the ability to create a fixed-angle construct with the freedom of +/-15 off-axis screw angulation. This enables the surgeon to: Adapt screw angulations to patient anatomy Capture specific fracture fragments Adjust screw trajectory after plate bending Position screws precisely to avoid joint penetration 2.7 mm low-profile metaphyseal compression screw: Low-profile alternative to a cortex screw Pulls the plate to the bone. Fully threaded, therefore not intended to generate interfragmentary compression Same thread as a variable angle locking screw or locking screw Can be replaced with a locking screw after plate-to-bone compression has been achieved 2.7 mm metaphyseal screw Cross-section of the VA-LCP Distal Humerus Plate, medial (1) and the LCP Distal Humerus Plate, medial (2) at the level of the medial epicondyle. 2.7 mm cortex screw

4 2.7 mm/3.5 mm VA-LCP Elbow Plates Variable angle screw holes Recess for screwhead minimizes screw prominence to create a low-profile construct when used at the nominal angle. Screws can also be angled within a 30 cone around the central axis of the plate hole. Olecranon plates Designed to treat various olecranon fracture patterns Combi Holes Accept 3.5 mm locking, 3.5 mm cortex and 4.0 mm cancellous bone screws Reconstruction plate segments Allow additional contouring of plates to fit patient anatomy Limited-contact shaft profile Limits plate-to-bone contact to reduce impairment of blood supply Suture holes and undercuts Allow passage of suture needles through the undercut after plate application Metaphyseal Screw Options Features variable angle locking holes that accept 2.7 mm variable angle locking, 2.7 mm metaphyseal, 2.7 mm locking, 2.7 mm cortex and 2.4 mm cortex screws Tapered plate tip Tapered end for submuscular plate insertion which may help to preserve tissue viability Rounded plate profile Minimizes the risk for soft tissue irritation

5 Three Types of Olecranon Plates Proximal ulna plates enable the surgeon to address the specific biomechanical requirements of each fracture pattern while minimizing irritations of the adjacent soft tissue. Proximal Olecranon Plate Olecranon Plate Extra-articular Proximal Ulna Plate Long proximal extension and more proximal screw options secure small olecranon fragments; designed to help neutralize the forces of the triceps muscle. 2 Notches designed to minimize interference with the triceps tendon. 3 Reduced shaft thickness minimizes plate prominence. Available in 2 holes 1 Proximal extension with multiple screw options secures the olecranon; designed to help neutralize the forces of the triceps muscle. 2 Multiple screws target and stabilize the coronoid. 3 Intermediate shaft thickness Available in 2, 4, 6, and 8 holes 1 Minimized proximal extension designed to avoid interference with the triceps tendon. 2 Shaft strength at least equivalent to 3.5 mm LCP plate Available in longer shaft lengths, including 6, 8, 10, and 12 holes

6 Choose your preferred plate configuration Perpendicular Plate configurations The VA-LCP Elbow Plating System offers three main double-plating configurations for the distal humerus. VA-LCP Distal Humerus Plates The plates offer multiple screw configurations for the medial and lateral columns, and the articular block. 1 Medial Plate The standard medial column plate for both perpendicular and parallel plating configurations. 2 Extended Medial Plate The extension buttresses the medial epicondyle and includes an ascending screw that stabilizes the medial column. Perpendicular, with support 3 Lateral Plate The lateral plate for the parallel-plating configuration that allows long screws into the trochlea from lateral to medial. 4 Posterolateral Plate The posterolateral plate for the perpendicular-plating configuration with screws targeting the capitellum. 3 5 Posterolateral Plate, with lateral support The screws from the lateral support target the articular block. Parallel

7 Simply Complete Synthes products are a combination of Lateral Distal Humerus Plate Posterolateral Distal Humerus Plate innovation and surgeon partnerships. A dedicated, global surgeon team was integral to the design of this system through extensive consultation and participation in several cadaver workshops. Surgeon interviews and feedback determined the key components necessary for the Synthes VA-LCP Elbow System. ONE Synthes 2.7 mm/3.5 mm VA-LCP Elbow System that is simply complete 180 plating option shown with Medial and Lateral Distal Humerus Plates Olecranon Plate 105 Surgeons interviewed globally to identify clinical features Dedicated, global surgeon development team provided extensive consultation on the complete system Medial Distal Humerus Plate Proximal Olecranon Plate Extra-articular Proximal Ulna Plate 250 Constructs tested in both materials (SS and TI). Static and Fatigue testing completed using biomechanical elbow model.* Testing on file at Synthes. Bench tests do not necessarily reflect clinical performance. 120 Skeletal specimens were analyzed to create anatomic precontoured design 78 Total implant options with the two longest lengths available sterile Extended Medial Distal Humerus Plate

8 2.7 mm/3.5 mm VA-LCP Elbow System Plates 2.7 mm/3.5 mm VA-LCP Proximal Olecranon Plates 0X ,.102: 2 holes, 73 mm, right and left 2.7 mm/3.5 mm VA-LCP Olecranon Plates 0X : 2, 4 and 6 holes, right 0X : 2, 4 and 6 holes, left 0X S,.308S*: 8 holes, sterile, right and left 2.7 mm/3.5 mm VA-LCP Extra-articular Proximal Ulna Plates 0X : 6, 8, 10 and 12 holes, right 0X : 6, 8, 10 and 12 holes, left 2.7 mm/3.5 mm VA-LCP Posterolateral Distal Humerus Plates with Lateral Support 0X : 3, 4, 7 and 9 holes, right 0X : 3, 4, 7 and 9 holes, left 0X S,.013S*: 11 and 13 holes, sterile, right 0X S,.113S*: 11 and 13 holes, sterile, left 2.7 mm/3.5 mm VA-LCP Medial Distal Humerus Plates 0X : 1, 2, 4 and 6 holes, right 0X : 1, 2, 4 and 6 holes, left 0X S,.410S*: 8 and 10 holes, sterile, right 0X S,.510S*: 8 and 10 holes, sterile, left 2.7 mm/3.5 mm VA-LCP Extended Medial Distal Humerus Plates 0X : 1, 2, 4 and 6 holes, right 0X : 1, 2, 4 and 6 holes, left 0X S,.610S*: 8 and 10 holes, sterile, right 0X S,.710S*: 8 and 10 holes, sterile, left 2.7 mm/3.5 mm VA-LCP Lateral Distal Humerus Plates 0X : 1, 2, 5 and 7 holes, right 0X : 1, 2, 5 and 7 holes, left 0X S,.811S*: 9 and 11 holes, sterile, right 0X S,.911S*: 9 and 11 holes, sterile, left 2.7 mm/3.5 mm VA-LCP Posterolateral Distal Humerus Plates 0X : 3, 4, 7 and 9 holes, right 0X : 3, 4, 7 and 9 holes, left 0X S,.213S*: 11 and 13 holes, sterile, right 0X S,.313S*: 11 and 13 holes, sterile, left Screws 2.7 mm Metaphyseal Screws, self-tapping, with T8 StarDrive recess 0X : 10 mm 70 mm (2 mm increments) Also Available S S 2.7 mm Metaphyseal Screws, self-tapping, with T8 StarDrive recess, 75 mm, sterile 2.7 mm Metaphyseal Screws, self-tapping, with T8 StarDrive recess, 80 mm, sterile 2.7 mm Variable Angle Locking Screws, self-tapping, with T8 StarDrive recess 0X : 10 mm 60 mm (2 mm increments) X = 2: Stainless Steel X = 4: Titanium (Ti-6Al-7Nb) *Available sterile only

9 Synthes USA 1302 Wrights Lane East West Chester, PA Telephone: (610) To order: (800) Fax: (610) Synthes (Canada) Ltd Meadowpine Boulevard Mississauga, Ontario L5N 6P9 Telephone: (905) To order: (800) Fax: (905) Synthes, Inc. or its affiliates. All rights reserved. Combi, LCP and Synthes are trademarks of Synthes, Inc. or its affiliates. Printed in U.S.A. 6/12 J11618-A

2.4 mm LCP Volar Column Distal Radius Plates. Part of the 2.4 mm LCP Distal Radius System.

2.4 mm LCP Volar Column Distal Radius Plates. Part of the 2.4 mm LCP Distal Radius System. 2.4 mm LCP Volar Column Distal Radius Plates. Part of the 2.4 mm LCP Distal Radius System. 12 anatomically shaped volar plates Multiple screw options for fixedangle support to articular surface Combi holes

More information

2.7 mm/3.5 mm Variable Angle LCP Elbow System DJ9257-B 1

2.7 mm/3.5 mm Variable Angle LCP Elbow System DJ9257-B 1 2.7 mm/3.5 mm Variable Angle LCP Elbow System DJ9257-B 1 System overview Simply complete: A comprehensive system, consisting of five (5) distal humerus plates and three (3) types of olecranon plates Implant

More information

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. Technique Guide 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. Table of Contents Introduction 2.4 mm Variable Angle LCP

More information

2.7 mm/3.5 mm LCP Distal Fibula Plate System. Part of the Synthes locking compression plate (LCP) system.

2.7 mm/3.5 mm LCP Distal Fibula Plate System. Part of the Synthes locking compression plate (LCP) system. 2.7 mm/3.5 mm LCP Distal Fibula Plate System. Part of the locking compression plate (LCP) system. Anatomically contoured Multiple screw options for fixedangle support Coaxial holes minimize screw head

More information

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system.

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system. Technique Guide 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system. Table of Contents Introduction 3.5 mm LCP Olecranon Plates 2 AO Principles 3 Indications 3 Clinical

More information

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system. Technique Guide 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system. Table of Contents Introduction 3.5 mm LCP Low Bend Medial Distal Tibia Plates

More information

LCP Periprosthetic System. Part of the Synthes locking compression plate (LCP) system.

LCP Periprosthetic System. Part of the Synthes locking compression plate (LCP) system. LCP Periprosthetic System. Part of the Synthes locking compression plate (LCP) system. 4.5 mm LCP curved broad plates 5.0 mm periprosthetic locking screws Orthopaedic cable components LCP Periprosthetic

More information

Variable Angle LCP Locking Technology

Variable Angle LCP Locking Technology BUILDING ON SUCCESS Variable Angle LCP Locking Technology The Evolution of Plating Technology Round Screw Hole Dynamic Compression Plate Limited-Contact Dynamic Compression Less Invasive Stabilization

More information

2.4 mm LCP Radial Head Plates. Part of the Synthes LCP Distal Radius Plate System.

2.4 mm LCP Radial Head Plates. Part of the Synthes LCP Distal Radius Plate System. 2.4 mm LCP Radial Head Plates. Part of the Synthes LCP Distal Radius Plate System. Technique Guide Instruments and Implants approved by the AO Foundation Table of Contents Introduction 2.4 mm LCP Radial

More information

LCP Distal Femur Plates. Shape based on Distal Femur LISS Plate design.

LCP Distal Femur Plates. Shape based on Distal Femur LISS Plate design. LCP Distal Femur Plates. Shape based on Distal Femur LISS Plate design. Preshaped plate Round threaded holes in plate head Combi holes in plate shaft LCP Distal Femur Plates Plates The LCP Distal Femur

More information

Compact Distal Radius System. Consolidated solution for Distal Radius Plating Systems

Compact Distal Radius System. Consolidated solution for Distal Radius Plating Systems Compact Distal Radius System. Consolidated solution for Distal Radius Plating Systems Designed to allow customized system configurations Variable Angle (VA) and Locking Compression Plate (LCP ) options

More information

Technique Guide. 2.7 mm/3.5 mm LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

Technique Guide. 2.7 mm/3.5 mm LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system. Technique Guide 2.7 mm/3.5 mm LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system. Table of Contents Introduction 2.7 mm/3.5 mm LCP Distal Fibula Plates 2 AO Principles

More information

Technique Guide. 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system.

Technique Guide. 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system. Technique Guide 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system. Table of Contents Introduction 3.5 mm LCP Proximal Humerus Plate 2 AO Principles

More information

3.5 mm LCP Tibial Plateau Sets. Configuration options.

3.5 mm LCP Tibial Plateau Sets. Configuration options. 3.5 mm LCP Tibial Plateau Sets. Configuration options. Multiple trays Multiple levels Multiple options 3.5 mm LCP Tibial Plateau Sets The tibial plateau trays allow the hospital to build a custom - ized

More information

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation. Technique Guide LCP Small Fragment System Table of Contents Introduction

More information

3.5 mm LCP Extra-articular Distal Humerus Plate

3.5 mm LCP Extra-articular Distal Humerus Plate Part of the DePuy Synthes Locking Compression Plate (LCP ) System 3.5 mm LCP Extra-articular Distal Humerus Plate Surgical Technique Table of Contents Introduction 3.5 mm LCP Extra-articular Distal Humerus

More information

LCP Anterior Ankle Arthrodesis Plates. Part of the Synthes Locking Compression Plate (LCP) System.

LCP Anterior Ankle Arthrodesis Plates. Part of the Synthes Locking Compression Plate (LCP) System. LCP Anterior Ankle Arthrodesis Plates. Part of the Synthes Locking Compression Plate (LCP) System. Technique Guide Instruments and implants approved by the AO Foundation Table of Contents Introduction

More information

Technique Guide. VA-LCP Distal Humerus Plates 2.7/3.5. The low-profile fixation system with variable angle locking technology.

Technique Guide. VA-LCP Distal Humerus Plates 2.7/3.5. The low-profile fixation system with variable angle locking technology. Technique Guide VA-LCP Distal Humerus Plates 2.7/3.5. The low-profile fixation system with variable angle locking technology. Image intensifier control Warning This description alone does not provide sufficient

More information

LCP Metaphyseal Plate for distal medial tibia. Anatomically precontoured metaphyseal plate.

LCP Metaphyseal Plate for distal medial tibia. Anatomically precontoured metaphyseal plate. Indications The LCP Metaphyseal Plate for distal medial tibia is a preshaped plate that allows optimal treatment of juxta-articular fractures of the distal tibia extending into the shaft area. This plate

More information

LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.

LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius. Technique Guide LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius. Table of Contents Introduction LCP Proximal

More information

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System.

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System. Technique Guide 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System. Table of Contents Introduction 3.5 mm LCP Low Bend Medial Distal

More information

2.4 mm Variable Angle LCP Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

2.4 mm Variable Angle LCP Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis. 2.4 mm Variable Angle LCP Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis. Technique Guide Instruments and implants approved by the AO Foundation Table

More information

VA-LCP Distal Humerus Plates 2.7/3.5. The low-profile fixation system with variable angle locking technology.

VA-LCP Distal Humerus Plates 2.7/3.5. The low-profile fixation system with variable angle locking technology. VA-LCP Distal Humerus Plates 2.7/3.5. The low-profile fixation system with variable angle locking technology. Technique Guide This publication is not intended for distribution in the USA. Instruments and

More information

3.5 mm LCP Olecranon Plates

3.5 mm LCP Olecranon Plates Part of the DePuy Synthes Locking Compression Plate (LCP ) System 3.5 mm LCP Olecranon Plates Surgical Technique Table of Contents Introduction 3.5 mm LCP Olecranon Plates 2 AO Principles 3 Indications

More information

Long Volar Plates for Diaphyseal-Metaphyseal Radius Fractures LCP. Dia-Meta Volar Distal Radius Plates. Surgical Technique

Long Volar Plates for Diaphyseal-Metaphyseal Radius Fractures LCP. Dia-Meta Volar Distal Radius Plates. Surgical Technique Long Volar Plates for Diaphyseal-Metaphyseal Radius Fractures LCP Dia-Meta Volar Distal Radius Plates Surgical Technique Table of Contents Introduction LCP Dia-Meta Volar Distal Radius Plates 2 AO Principles

More information

Distal Radius Sterile Kit. Optimization And Efficiency You Can Rely On

Distal Radius Sterile Kit. Optimization And Efficiency You Can Rely On Distal Radius Sterile Kit Optimization And Efficiency You Can Rely On Introducing The Distal Radius Sterile Kit Improved OR Workflow The Distal Radius Sterile Kit provides high-quality single-use implants

More information

Technique Guide. Self-Drilling Schanz Screws. Designed to optimize the bone/pin interface.

Technique Guide. Self-Drilling Schanz Screws. Designed to optimize the bone/pin interface. Technique Guide Self-Drilling Schanz Screws. Designed to optimize the bone/pin interface. Self-Drilling Schanz Screws The self-drilling Schanz screw has been specifically designed to optimize the bone/pin

More information

Technique Guide. Small Fragment Locking Compression Plate (LCP) System. Stainless steel and titanium.

Technique Guide. Small Fragment Locking Compression Plate (LCP) System. Stainless steel and titanium. Technique Guide Small Fragment Locking Compression Plate (LCP) System. Stainless steel and titanium. Table of Contents Introduction Small Fragment Locking Compression Plate (LCP) System 2 AO Principles

More information

Low Bend Distal Tibia Plates

Low Bend Distal Tibia Plates Part of the DePuy Synthes Locking Compression Plate (LCP ) System 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique Table of Contents Introduction 3.5 mm LCP Low Bend Medial Distal Tibia

More information

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. Technique Guide 2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. Table of Contents Introduction 2.4

More information

3.5 mm LCP Distal Humerus Plates

3.5 mm LCP Distal Humerus Plates Part of the DePuy Synthes Locking Compression Plate (LCP ) System 3.5 mm LCP Distal Humerus Plates Surgical Technique Table of Contents Introduction 3.5 mm LCP Distal Humerus Plates 2 AO Principles 4 Indications

More information

Pediatric LCP Hip Plate. For osteotomy and trauma applications in the proximal femur.

Pediatric LCP Hip Plate. For osteotomy and trauma applications in the proximal femur. Pediatric LCP Hip Plate. For osteotomy and trauma applications in the proximal femur. Angular stability Intraoperative correction and flexibility Universal design Pediatric LCP Hip Plate The Pediatric

More information

2.7 mm/3.5 mm VA-LCP Anterior Clavicle Plates. Part of the Synthes modular clavicle plate system.

2.7 mm/3.5 mm VA-LCP Anterior Clavicle Plates. Part of the Synthes modular clavicle plate system. 2.7 mm/3.5 mm VA-LCP Anterior Clavicle Plates. Part of the Synthes modular clavicle plate system. Technique Guide Instruments and implants approved by the AO Foundation Table of Contents Introduction 2.7

More information

modular ClaVICle PlaTe system

modular ClaVICle PlaTe system modular ClaVICle PlaTe system 3.7 mm/3.3 mm VA LCP Anterior Clavicle Plates and 3.3 mm Superior Anterior Clavicle Plates surgical TeChnIque Table of Contents Introduction Modular Clavicle Plate System

More information

LCP Extra-articular Distal Humerus Plate.

LCP Extra-articular Distal Humerus Plate. Technique Guide LCP Extra-articular Distal Humerus Plate. The anatomically shaped and angular stable fixation system for extraarticular fractures of the distal humerus. Table of Contents Introduction

More information

OBSOLETED. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

OBSOLETED. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation. Surgical Technique LCP Small Fragment System This publication

More information

Technique Guide. TomoFix Osteotomy System. A comprehensive plating system for stable fixation of osteotomies around the knee.

Technique Guide. TomoFix Osteotomy System. A comprehensive plating system for stable fixation of osteotomies around the knee. Technique Guide TomoFix Osteotomy System. A comprehensive plating system for stable fixation of osteotomies around the knee. Table of Contents Introduction TomoFix Osteotomy System 2 AO Principles 4 Indications

More information

3.5 mm LCP Hook Plate

3.5 mm LCP Hook Plate Part of the DePuy Synthes Locking Compression Plate (LCP ) System 3.5 mm LCP Hook Plate Surgical Technique Table of Contents Introduction 3.5 mm LCP Hook Plate 2 AO Principles 4 Indications 5 Clinical

More information

Instrument and Implant for wrist fracture

Instrument and Implant for wrist fracture Instrument and Implant for wrist fracture Jansri Janpanya Product specialist The Bangkok Unitrade Co,.ltd. Objectives Type of LCP for distal radius Fx. The new LCP design for distal radius Fx. Have knowledge

More information

Technique Guide. Adjustable Distal Radius Fixator. Part of the Synthes External Fixation Systems.

Technique Guide. Adjustable Distal Radius Fixator. Part of the Synthes External Fixation Systems. Technique Guide Adjustable Distal Radius Fixator. Part of the Synthes External Fixation Systems. Table of Contents Introduction Adjustable Distal Radius Fixator 2 Indications 3 Surgical Technique Configure

More information

VA-LCP Olecranon Plates 2.7/3.5. The fracture-specific low-profile fixation system with variable angle locking technology.

VA-LCP Olecranon Plates 2.7/3.5. The fracture-specific low-profile fixation system with variable angle locking technology. VA-LCP Olecranon Plates 2.7/3.5. The fracture-specific low-profile fixation system with variable angle locking technology. Surgical Technique This publication is not intended for distribution in the USA.

More information

The Wrist Fusion Set. Stainless Steel and Titanium TECHNIQUE GUIDE. Instruments and implants approved by the AO Foundation

The Wrist Fusion Set. Stainless Steel and Titanium TECHNIQUE GUIDE. Instruments and implants approved by the AO Foundation The Wrist Fusion Set Stainless Steel and Titanium TECHNIQUE GUIDE Instruments and implants approved by the AO Foundation Three Plate Options Stainless Steel or Titanium* Standard Bend Stainless Steel [242.510]

More information

Pediatric LCP Plate System. For osteotomies and fracture fixation of the proximal and distal femur.

Pediatric LCP Plate System. For osteotomies and fracture fixation of the proximal and distal femur. Pediatric LCP Plate System. For osteotomies and fracture fixation of the proximal and distal femur. Angular stability Intraoperative correction and flexibility Universal design Indications The Pediatric

More information

LCP Low Bend Medial Distal Tibia Plates 3.5 mm. Anatomic plates with low profile head for intra- and extraarticular fractures.

LCP Low Bend Medial Distal Tibia Plates 3.5 mm. Anatomic plates with low profile head for intra- and extraarticular fractures. LCP Low Bend Medial Distal Tibia Plates 3.5 mm. Anatomic plates with low profile head for intra- and extraarticular fractures. Surgical Technique This publication is not intended for distribution in the

More information

The CerviFix System. Including the StarLock Components. CerviFix Clamp and Screw. StarLock Clamp and Screw

The CerviFix System. Including the StarLock Components. CerviFix Clamp and Screw. StarLock Clamp and Screw The CerviFix System Including the StarLock Components CerviFix Clamp and Screw StarLock Clamp and Screw The CerviFix System The CerviFix System is a comprehensive set of implants, including clamps, screws,

More information

Clinical. Solutions. Synthes Solutions. Foot and Ankle.

Clinical. Solutions. Synthes Solutions. Foot and Ankle. Clinical Solutions Foot and Ankle. Foot and Ankle. Fractures of the tibial shaft Fractures of the distal fibula Fractures of the distal tibia Fractures and osteotomies of the calcaneus Arthrodesis Fractures,

More information

2.7 mm/3.5 mm LCP Distal Fibula Plate

2.7 mm/3.5 mm LCP Distal Fibula Plate Part of the DePuy Synthes Locking Compression Plate (LCP ) System 2.7 mm/3.5 mm LCP Distal Fibula Plate Surgical Technique Table of Contents Introduction 2.7 mm/3.5 mm LCP Distal Fibula Plates 2 AO Principles

More information

3.5 mm Locking Attachment Plate

3.5 mm Locking Attachment Plate For Treatment of Periprosthetic Fractures 3.5 mm Locking Attachment Plate Surgical Technique Table of Contents Introduction 3.5 mm Locking Attachment Plate 2 Indications 4 Surgical Technique Preparation

More information

Technique Guide. 4.5 mm LCP Proximal Tibia Plates. Part of the Synthes LCP Periarticular Plating System.

Technique Guide. 4.5 mm LCP Proximal Tibia Plates. Part of the Synthes LCP Periarticular Plating System. Technique Guide 4.5 mm LCP Proximal Tibia Plates. Part of the Synthes LCP Periarticular Plating System. Table of Contents Introduction 4.5 mm LCP Proximal Tibia Plates 2 AO Principles 4 Indications 5 Surgical

More information

LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.

LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius. LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius. Surgical Technique This publication is not intended for

More information

Technique Guide. LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

Technique Guide. LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system. Technique Guide LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system. Table of Contents Introduction LCP Distal Fibula Plates 2 AO Principles 4 Indications 5 Surgical Technique

More information

3.5 mm LCP Superior and Superior Anterior Clavicle Plates. Part of the Synthes modular clavicle plate system.

3.5 mm LCP Superior and Superior Anterior Clavicle Plates. Part of the Synthes modular clavicle plate system. 3.5 mm LCP Superior and Superior Anterior Clavicle Plates. Part of the Synthes modular clavicle plate system. Technique Guide Instruments and implants approved by the AO Foundation Table of Contents Introduction

More information

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system. LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system. Technique Guide This publication is not intended for distribution in the USA. Instruments

More information

Thoracolumbar Spine Locking Plate (TSLP) System. A low-profile plating system for anterior stabilization of the thoracic and lumbar spine.

Thoracolumbar Spine Locking Plate (TSLP) System. A low-profile plating system for anterior stabilization of the thoracic and lumbar spine. Thoracolumbar Spine Locking Plate (TSLP) System. A low-profile plating system for anterior stabilization of the thoracic and lumbar spine. Technique Guide Instruments and implants approved by the AO Foundation

More information

Technique Guide. Midface Distractor System. For the temporary stabilization and gradual lengthening of the cranial or midfacial bones.

Technique Guide. Midface Distractor System. For the temporary stabilization and gradual lengthening of the cranial or midfacial bones. Technique Guide Midface Distractor System. For the temporary stabilization and gradual lengthening of the cranial or midfacial bones. Table of Contents Introduction Midface Distractor System 2 Indications

More information

Basic Trocar System. Basic transbuccal instrumentation system for simplified intraoral plate and screw application.

Basic Trocar System. Basic transbuccal instrumentation system for simplified intraoral plate and screw application. Basic Trocar System. Basic transbuccal instrumentation system for simplified intraoral plate and screw application. Lightweight, ergonomic design Allows placement of three screw sizes Size-specific, colorcoded

More information

Thoracolumbar Anterior Compression (TAC) System. Allows distraction, compression, and lateral fixation of the lower thoracic and lumbar spine.

Thoracolumbar Anterior Compression (TAC) System. Allows distraction, compression, and lateral fixation of the lower thoracic and lumbar spine. Thoracolumbar Anterior Compression (TAC) System. Allows distraction, compression, and lateral fixation of the lower thoracic and lumbar spine. Technique Guide Instruments and implants approved by the AO

More information

Variable Angle LCP Forefoot/Midfoot System 2.4/2.7. Procedure specific plates for osteotomies, arthrodeses and fractures of the foot.

Variable Angle LCP Forefoot/Midfoot System 2.4/2.7. Procedure specific plates for osteotomies, arthrodeses and fractures of the foot. Variable Angle LCP Forefoot/Midfoot System 2.4/2.7. Procedure specific plates for osteotomies, arthrodeses and fractures of the foot. Compression technology Variable angle locking technology Anatomic and

More information

Surgical Technique. Lower Extremity Plates and Straight Plates

Surgical Technique. Lower Extremity Plates and Straight Plates Surgical Technique Lower Extremity Plates and Straight Plates 2 Table of contents Overview...4 Indications... 4 Contraindications... 4 Screw Options... 5 Straight Plate Options... 6 Proximal Tibia Plate

More information

Variable Angle LCP Volar Rim Distal Radius Plate 2.4. For fragment-specific fracture fixation with variable angle locking technology.

Variable Angle LCP Volar Rim Distal Radius Plate 2.4. For fragment-specific fracture fixation with variable angle locking technology. Technique Guide Variable Angle LCP Volar Rim Distal Radius Plate 2.4. For fragment-specific fracture fixation with variable angle locking technology. Image intensifier control Warning This description

More information

VA-LCP Distal Humerus Plates 2.7/3.5. The low-profile fixation system with variable angle locking technology.

VA-LCP Distal Humerus Plates 2.7/3.5. The low-profile fixation system with variable angle locking technology. VA-LCP Distal Humerus Plates 2.7/3.5. The low-profile fixation system with variable angle locking technology. Surgical Technique This publication is not intended for distribution in the USA. Instruments

More information

MINI TIBIAL PLATEAU LEVELING OSTEOTOMY (TPLO) SYSTEM

MINI TIBIAL PLATEAU LEVELING OSTEOTOMY (TPLO) SYSTEM MINI TIBIAL PLATEAU LEVELING OSTEOTOMY (TPLO) SYSTEM For stabilizing osteotomies of the canine and feline proximal tibia SURGICAL TECHNIQUE TABLE OF CONTENTS INTRODUCTION Mini Tibial Plateau Leveling

More information

2.4 mm Variable Angle LCP Volar Rim Distal Radius Plates

2.4 mm Variable Angle LCP Volar Rim Distal Radius Plates For Fragment-Specific Fracture Fixation With Variable Angle Locking Technology 2.4 mm Variable Angle LCP Volar Rim Distal Radius Plates Surgical Technique Table of Contents Introduction 2.4 mm Variable

More information

Part of the DePuy Synthes Locking Compression Plate (LCP ) System. 3.5 mm LCP Medial Proximal Tibia Plates

Part of the DePuy Synthes Locking Compression Plate (LCP ) System. 3.5 mm LCP Medial Proximal Tibia Plates Part of the DePuy Synthes Locking Compression Plate (LCP ) System 3.5 mm LCP Medial Proximal Tibia Plates Surgical Technique Table of Contents Introduction 3.5 mm LCP Medial Proximal Tibia Plates 2 AO

More information

Technique Guide. Small Fragment Locking Compression Plate (LCP) System. Stainless Steel and Titanium.

Technique Guide. Small Fragment Locking Compression Plate (LCP) System. Stainless Steel and Titanium. Technique Guide Small Fragment Locking Compression Plate (LCP) System. Stainless Steel and Titanium. Table of Contents Introduction Small Fragment Locking Compression Plate (LCP) System 2 AO Principles

More information

A Fusion of Versatility, Performance and Ease.

A Fusion of Versatility, Performance and Ease. MATRIX Spine System. Degenerative and Deformity. System Guide A Fusion of Versatility, Performance and Ease. Instruments and implants approved by the AO Foundation The MATRIX Spine System is a universal

More information

designed to advance the treatment of hip fractures.

designed to advance the treatment of hip fractures. designed to advance the treatment of hip fractures. introducing the tfn-advanced proximal femoral nailing system (tfna). the tfna system is a new system designed to solve a wide range of unmet needs for

More information

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability. LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability. Technique Guide LCP Small Fragment System Table of Contents Introduction

More information

2.4 mm Variable Angle LCP Dorsal Distal Radius Plate

2.4 mm Variable Angle LCP Dorsal Distal Radius Plate For Fragment-Specific Fracture Fixation With Variable Angle (VA) Locking Technology 2.4 mm Variable Angle LCP Dorsal Distal Radius Plate Surgical Technique Table of Contents Introduction 2.4 mm VA LCP

More information

Surgical Technique. Elbow Plating System

Surgical Technique. Elbow Plating System Surgical Technique Elbow Plating System Acumed is a global leader of innovative orthopaedic and medical solutions. We are dedicated to developing products, service methods, and approaches that improve

More information

Surgical Technique. This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation.

Surgical Technique. This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. LCP Extra-articular Distal Humerus Plate. The anatomically shaped and angular stable fixation system for extraarticular fractures of the distal humerus. Surgical Technique This publication is not intended

More information

Technique Guide. DCP and LC-DCP Systems. Dynamic Compression Plates (DCP) and Dynamic Compression Plates with Limited Bone Contact (LC-DCP).

Technique Guide. DCP and LC-DCP Systems. Dynamic Compression Plates (DCP) and Dynamic Compression Plates with Limited Bone Contact (LC-DCP). Technique Guide DCP and LC-DCP Systems. Dynamic Compression Plates (DCP) and Dynamic Compression Plates with Limited Bone Contact (LC-DCP). Table of Contents Introduction DCP and LC-DCP Systems 2 Indications

More information

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. 2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. Surgical Technique This publication is not intended

More information

Small Fragment Locking Compression Plate (LCP ) System

Small Fragment Locking Compression Plate (LCP ) System Stainless Steel and Titanium Small Fragment Locking Compression Plate (LCP ) System Surgical Technique Table of Contents Introduction Small Fragment Locking Compression Plate (LCP) System 2 AO Principles

More information

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1) Distal Radius Plate Instrument and Implant Set Surgical Technique Discontinued December 2017 DSUS/TRM/0916/1063(1) The Distal Radius Plates Indications For fixation of fractures and osteotomies, including

More information

low ProfIle neuro PlaTIng system

low ProfIle neuro PlaTIng system low ProfIle neuro PlaTIng system surgical TeChnIque Table of Contents Introduction Low Profile Neuro Cranial Plating System 2 Surgical Technique Technique 5 Product Information Low Profile Neuro Plates

More information

VA-LCP Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

VA-LCP Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle. Technique Guide VA-LCP Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle. Table of Contents Introduction VA-LCP Anterior

More information

Locking Radial Head Plates

Locking Radial Head Plates Locking Radial Head Plates Locking Radial Head Plates Since 1988, Acumed has been designing solutions to the demanding situations facing orthopaedic surgeons, hospitals and their patients. Our strategy

More information

Ordering information. LCP Locking Compression Plate. Combine without compromise.

Ordering information. LCP Locking Compression Plate. Combine without compromise. Ordering information LCP Locking Compression Plate. Combine without compromise. Table of Contents Small Fragment System Large Fragment System LCP Instruments Emergency Instruments Implants Humerus Plates,

More information

Surgical Technique. Distal Humerus Locking Plate

Surgical Technique. Distal Humerus Locking Plate Surgical Technique Distal Humerus Locking Plate PERI-LOC Locked Plating System Distal Humerus Locking Plate Surgical Technique Table of Contents Introduction...2 Indications...3 Plate Features...3 Patient

More information

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System. Technique Guide LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System. Table of Contents Introduction Features and Benefits 2 AO ASIF Principles 4 Indications 5 Surgical

More information

Technique Guide. IMF Screw Set. For intermaxillary fixation.

Technique Guide. IMF Screw Set. For intermaxillary fixation. Technique Guide IMF Screw Set. For intermaxillary fixation. Table of Contents Introduction IMF Screw Set 2 Indications and Contraindications 3 Surgical Technique Preparation 4 Insert IMF Screw 6 Insert

More information

CSLP Quick Lock Screws. Preassembled expansionhead screw and locking screw for use with Cervical Spine Locking Plates (CSLP).

CSLP Quick Lock Screws. Preassembled expansionhead screw and locking screw for use with Cervical Spine Locking Plates (CSLP). CSLP Quick Lock Screws. Preassembled expansionhead screw and locking screw for use with Cervical Spine Locking Plates (CSLP). Technique Guide Instruments and implants approved by the AO Foundation Table

More information

MatrixMANDIBLE Subcondylar Plates. Specialized implants for the subcondylar region.

MatrixMANDIBLE Subcondylar Plates. Specialized implants for the subcondylar region. MatrixMANDIBLE Subcondylar Plates. Specialized implants for the subcondylar region. Addressing a variety of subcondylar fractures Optimized shapes and screw placement Stable fixation . Specialized implants

More information

LCP Distal Humerus Plates

LCP Distal Humerus Plates The anatomic fixation system for the distal humerus with angular stability Surgical technique LCP Locking Compression Plate Contents Indications and contraindications 2 Implants 3 Instruments 5 Preparation

More information

DOUBLE/TRIPLE PELVIC OSTEOTOMY PLATES For Treating Coxofemoral Joint Instability and Subluxation in Immature Dogs

DOUBLE/TRIPLE PELVIC OSTEOTOMY PLATES For Treating Coxofemoral Joint Instability and Subluxation in Immature Dogs DOUBLE/TRIPLE PELVIC OSTEOTOMY PLATES For Treating Coxofemoral Joint Instability and Subluxation in Immature Dogs Instruments and implants approved by the AO Foundation. This publication is not intended

More information

Elbow Plating System

Elbow Plating System Elbow Plating System Elbow Plating System Acumed is a global leader of innovative orthopaedic and medical solutions. We are dedicated to developing products, service methods and approaches that improve

More information

ANATOMIC LOCKED PLATING SYSTEM

ANATOMIC LOCKED PLATING SYSTEM ANATOMIC LOCKED PLATING SYSTEM There is only one...dvr Anatomic. There is only one... ANATOMIC LOCKED PLATING SYSTEM Distal Tibia TiMAX for strength, biocompatibility and enhanced imaging capabilities

More information

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability. LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability. Technique Guide LCP Small Fragment System Table of Contents Introduction

More information

Small External Fixator Nonspanning Wrist Frame. For the treatment of wrist fractures.

Small External Fixator Nonspanning Wrist Frame. For the treatment of wrist fractures. Small External Fixator Nonspanning Wrist Frame. For the treatment of wrist fractures. Technique Guide Part of the Small External Fixation System Small External Fixator Nonspanning Wrist Frame When to use

More information

Surgical Technique. Olecranon Locking Plate

Surgical Technique. Olecranon Locking Plate Surgical Technique Olecranon Locking Plate PERI-LOC Locked Plating System Olecranon Locking Plate Surgical Techniquealog Infor Table of Contents Introduction...2 Indications...3 Plate Features...3 Patient

More information

3.5 MM VA-LCP PROXIMAL TIBIA PLATE SYSTEM

3.5 MM VA-LCP PROXIMAL TIBIA PLATE SYSTEM 3.5 MM VA-LCP PROXIMAL TIBIA PLATE SYSTEM Part of the DePuy Synthes Variable Angle Periarticular Plating System SURGICAL TECHNIQUE TABLE OF CONTENTS INTRODUCTION 3.5 mm VA-LCP Proximal Tibial Plate 2 AO

More information

The Orthopaedic Cable System TECHNIQUE GUIDE

The Orthopaedic Cable System TECHNIQUE GUIDE The Orthopaedic Cable System TECHNIQUE GUIDE Original Instruments and Implants of the Association for the Study of Internal Fixation AO ASIF Table of Contents INTRODUCTION Indications.....................................

More information

Technique Guide. 3.5 mm LCP Proximal Tibia Plate. Part of the Synthes Small Fragment LCP System.

Technique Guide. 3.5 mm LCP Proximal Tibia Plate. Part of the Synthes Small Fragment LCP System. Technique Guide 3.5 mm LCP Proximal Tibia Plate. Part of the Synthes Small Fragment LCP System. Table of Contents AO ASIF Principles of Internal Fixation 4 Indications/Contraindications 5 Surgical Technique

More information

Medium External Fixator Humeral Shaft Frame. Modular frame for upper extremity use.

Medium External Fixator Humeral Shaft Frame. Modular frame for upper extremity use. Medium External Fixator Humeral Shaft Frame. Modular frame for upper extremity use. Technique Guide Part of the Medium External Fixation System MRI Information Synthes Medium External Fixation devices

More information

COMPACT ANKLE FRACTURE SYSTEM

COMPACT ANKLE FRACTURE SYSTEM COMPACT ANKLE FRACTURE SYSTEM Consolidated ankle fracture solution for surgery centers SURGICAL TECHNIQUE TABLE OF CONTENTS INTRODUCTION Compact Ankle Fracture System 2 AO Principles 8 Indications 9 Clinical

More information

2.4 mm LCP Distal Radius System

2.4 mm LCP Distal Radius System A Comprehensive Plating System to Address a Variety of Fracture Patterns 2.4 mm LCP Distal Radius System Surgical Technique Table of Contents Introduction 2.4 mm LCP Distal Radius System 2 AO Principles

More information

LCP Metaphyseal Plates. For extra-articular fractures.

LCP Metaphyseal Plates. For extra-articular fractures. LCP Metaphyseal Plates. For extra-articular fractures. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. Image intensifier

More information