Ureteral Stent. Pusher. Guide Wire. Clamp

Size: px
Start display at page:

Download "Ureteral Stent. Pusher. Guide Wire. Clamp"

Transcription

1

2 YELLOW-STAR Ureteral Stents

3 YELLOW-STAR Double-J Ureteral Stents-Set PC-coated Set Components YELLOW-STAR pusher guide wire Ureteral Stent Polyurethane (PUR) PC coating to minimise risk of infection and encrustation, resulting in extended indwelling time Drainage openings in pigtails and shaft Open or closed tip Markings for exact positioning Radiopaque Pusher : 40 cm PTFE-coated Clamp Only in sets with closed tip 1.2

4 YELLOW-STAR Double-J Ureteral Stents-Set PC-coated Open tip without with Stiffness EP EP straight standard EP EP straight standard 0 24 EP EP straight standard 0 2 EP-4102 EP straight standard 0 28 EP EP straight standard 0 30 EP EP straight standard EP EP straight standard 07 2 EP EP straight standard EP EP straight standard EP EP straight standard EP EP straight standard 08 2 EP EP straight standard EP EP straight standard EP EP straight standard Closed tip without with Stiffness EP EP straight standard EP EP straight standard 0 24 EP EP straight standard 0 2 EP-4002 EP straight standard 0 28 EP EP straight standard 0 30 EP EP straight standard EP EP straight standard 07 2 EP EP straight standard EP EP straight standard EP EP straight standard EP EP straight standard 08 2 EP EP straight standard EP EP straight standard EP EP straight standard 1.2

5 YELLOW-STAR Double-J Ureteral Stent-Set PC-coated, flexible length Set Components YELLOW-STAR pusher guide wire Ureteral Stent Polyurethane (PUR) PC coating to minimise risk of infection and encrustation, resulting in extended indwelling time Multiple coils on both ends for flexible shaft length from 22 to 30 cm Less risk of dislocation Drainage openings in pigtails and shaft Open or closed tip Markings for exact positioning Radiopaque Pusher : 40 cm PTFE-coated Clamp Only in sets with closed tip bladder side kidney side 1.3

6 YELLOW-STAR Double-J Ureteral Stent-Set PC-coated, flexible length Open tip without with Stiffness EP BS EP BS straight standard EP BS EP BS straight standard EP BS EP BS straight standard EP BS EP BS straight standard Closed tip with Stiffness EP BS straight standard EP BS straight standard EP BS straight standard EP BS straight standard 1.3

7 YELLOW-STAR Double-J Ureteral Stents-Set PC-coated, steerable Set Components YELLOW-STAR steering device Ureteral Stent Polyurethane (PUR) PC coating to minimise risk of infection and encrustation, resulting in extended indwelling time Drainage openings in pigtails and shaft Open or closed tip Markings for exact positioning Radiopaque Steering Device Pusher Disconnector : 53 cm PTFE-coated Clamp Only in sets with closed tip 1.4

8 YELLOW-STAR Double-J Ureteral Stents-Set PC-coated, steerable Open tip without with Stiffness EP EP straight standard EP EP straight standard 0 24 EP EP straight standard / movable core 0 2 EP-4702 EP straight standard / movable core 0 28 EP EP straight standard / movable core 0 30 EP EP straight standard / movable core EP EP straight standard / movable core 07 2 EP EP straight standard / movable core EP EP straight standard / movable core EP EP straight standard / movable core EP EP straight standard / movable core 08 2 EP EP straight standard / movable core EP EP straight standard / movable core EP EP straight standard / movable core Closed tip with Stiffness EP straight standard EP straight standard 0 24 EP J-tip standard / movable core 0 2 EP J-tip standard / movable core 0 28 EP J-tip standard / movable core 0 30 EP J-tip standard / movable core EP J-tip standard / movable core 07 2 EP J-tip standard / movable core EP J-tip standard / movable core EP J-tip standard / movable core EP J-tip standard / movable core 08 2 EP J-tip standard / movable core EP J-tip standard / movable core EP J-tip standard / movable core 1.4

9 YELLOW-STAR Double-J Ureteral Stent-Set PC-coated, steerable with coupling Set Components YELLOW-STAR steering device with coupling Ureteral Stent Polyurethane (PUR) PC coating to minimise risk of infection and encrustation, resulting in extended indwelling time Drainage openings in pigtails and shaft Open or closed tip Markings for exact positioning Radiopaque Steering Device with Coupling Pusher Disconnector Coupling to fasten guide wire : 43 cm PTFE-coated 1.5

10 Ureteral Stents Introduction and general information Introduction On the following pages, we would like to provide you with a comprehensive portfolio of our ureteral stents. Regardless of the indication, you are sure to find the appropriate product here. Material Polyurethane (PUR) All UROTECH ureteral stents are produced from aliphatic polyurethane (PUR) that has been specifically developed for medical applications. Unlike other materials, PUR shows minimal adhesion to blood cells and has a very low-grade inflammatory effect on tissue due to its physical and chemical properties. PUR becomes soft in a moist environment at body temperature, significantly limiting the risks of traumatic injury to surrounding tissue. Experimental tests and practical experience have shown that PUR is one of the least thrombogenic and most tissuecompatible materials for implantable medical products. Indwelling time All UROTECH ureteral stents are approved for long-term use and can remain inside a patient for several months. The additional layer of phosphorylcholine (PC) on the ureteral stents significantly reduces the risk of encrustation and infection. However, due to the heterogeneity of indications and individual differences between patients, regular follow-up examinations should be performed by the treating physician. measurements In accordance with international norms (ASTMF-1828), the length of our ureteral stents is always indicated without including the J-tip this equals the shaft length (Fig. 1). Variations In addition to our large catalog of standard ureteral stents, you can order many different custom variations based on your clinical needs. E.g. stents: with attached suture without drainage openings in shaft Fig. 1 bladder end length specification of all double-j ureteral stents (without pigtails) kidney end bladder side kidney side 1.1 (1) Referenzen: Russel JC.; Bacteria, Biofilm and Devices: The Possible Protective Role of Phosphorylcholine Materials; J. Endourology 2000; 14(1): Stickler DJ, Evans A. et al.; Strategies for the control of catheter encrustation; Int. J. of Antimicrobial Agents 2002; 19(): Heidenreich A., Becker T. et al.; Morbidity of internal Ureteral Stents: Prospective randomized Trial of Polyurethane versus Phosphorylcholine Coated Stents; Poster # 139 XVIIth Congress of European Association of Urology (EAU) Birmingham 2002

11 YELLOW-STAR Double-J Ureteral Stent-Set PC-coated, steerable with coupling Open tip without with Stiffness EP EP straight standard EP EP straight standard 0 24 EP EP straight standard / movable core 0 2 EP-5702 EP straight standard / movable core 0 28 EP EP straight standard / movable core 0 30 EP EP straight standard / movable core EP EP straight standard / movable core 07 2 EP EP straight standard / movable core EP EP straight standard / movable core EP EP straight standard / movable core EP EP straight standard / movable core 08 2 EP EP straight standard / movable core EP EP straight standard / movable core EP EP straight standard / movable core Closed tip with Stiffness EP straight standard EP straight standard 0 24 EP J-tip standard / movable core 0 2 EP J-tip standard / movable core 0 28 EP J-tip standard / movable core 0 30 EP J-tip standard / movable core EP J-tip standard / movable core 07 2 EP J-tip standard / movable core EP J-tip standard / movable core EP J-tip standard / movable core EP J-tip standard / movable core 08 2 EP J-tip standard / movable core EP J-tip standard / movable core EP J-tip standard / movable core 1.5

12 PHOSPHORYLCHOLINE COATING UROTECH the worldwide only Manufacturer of PC coated Urological Devices More than 10 years Phosphorylcholine coating Phosphorylcholine is a biocompatible and durable sealing of the inner and outer surface of implants to prevent biofi lm formation and subsequent encrustation. It is successfully used not only in urology but also in other medical fi elds (coronary stents, contact lenses). Since 10 years now UROTECH is successfully using Phosphorylcholine coating (PC) on urological devices. Phosphorylcholine verifi ably lowers the risk of encrustations and infections, which results in prolonging the indwelling time of ureteral stents and nephrostomy catheters. The PC coated surfaces show, independent from the material, signifi cant less adsorptions of bacteria. As a result Phosphorylcholine is highly suitable for urological applications. a. b. Cross-section of a catheter after three month implantation in the same patient a. uncoated b. PC coated Phosphorylcholine coated ureteral stents minimize significant stent associated morbidity frequency of urinary tract infections cost for accompanying medication (anticholinergics, antibiotics) 4

13 The Effect is comparable to the camoufl age protection of a chameleon. Chameleons change colour in response to changes in light, or temperature thus protecting itselves from enemies by adopting visually to its surroundings. PC coated ureteral stents use an intelligent thermal and biological camoufl age effect sealing its surface against any environmental infl uences. For devices implanted in the urinary tract, encrustation of the implant`s surface is the most common technical problem. The camouflage effect of PC coated stents Even a short time after implantation a biofi lm formation on the surface of catheters is observed, containing multiple microorganism and extracellular matrices. This biofi lm can be seen as a permanent reservoir of these bacteria, protecting them against antibiotic therapy and maintaining a catheter associated urinary tract infection (CAUTI). Most of these microorganism are forming ureasplitting enzymes (urease) resulting in an increasing ph-level of urine and in the biofi lm. If the ph-level exceeds the neutral point (ph=7), different soluted molecules precipitate and cristalize on the surface of the implant. An encrustation is formed, the inner lumen of the catheter narrows and the implant doesn t function anymore. Phosphorylcholine coating keeps the ph level on the stent surface constant which minimizes the cristalization of molecules leading to a signifi cantly lower incrustation rate. Various clinical studies exist proving the effectiveness of Phosphorylcholine`s capacity of increasing the maximum indwelling time of ureteral stents. 5 VERTELLUS BIOMATERIALS PC is a trademark of Vertellus Specialties UK, Limited, all rights reserved.

Ureteral Stent. Pusher. Guide Wire

Ureteral Stent. Pusher. Guide Wire Yellow-Star Tumor-Stent Double-J Ureteral Stents-Set PC-coated Set Components YELLOW-STAR Tumor-Stent pusher guide wire Ureteral Stent Polyurethane (PUR) PC coating to minimise risk of infection and encrustation,

More information

Endosil Silicone Double Loop Ureteral Stent

Endosil Silicone Double Loop Ureteral Stent Endosil Silicone Double Loop Ureteral Stent B B Indwelling Up to 12 month ENDOUROLOGY C F B Soft Silicone C Better Tolerance for the patient R R RR Prevent risk of Migration ProductsCatalogue.EN.2.3 17

More information

Catheters and Wires. Dr. Vaibhav Jain MD,DNB,MNAMS Senior Consultant, IR Medanta, the Medicity, Gurgaon

Catheters and Wires. Dr. Vaibhav Jain MD,DNB,MNAMS Senior Consultant, IR Medanta, the Medicity, Gurgaon Catheters and Wires Dr. Vaibhav Jain MD,DNB,MNAMS Senior Consultant, IR Medanta, the Medicity, Gurgaon Guidewires: Guidewires (solid wires navigated within the vascular system / extravascular tract) act

More information

Contributor contact details

Contributor contact details Contributor contact details Preface Fundamentals p. 1 Introduction to biofilms in urology p. 3 Introduction p. 3 What is a biofilm and why do they form? p. 4 Biofilm formation and structure p. 5 p. xv

More information

S I L I CONE BALLOON CATHETER. 98en TRANSURETHRAL BLADDER DRAINAGE

S I L I CONE BALLOON CATHETER. 98en TRANSURETHRAL BLADDER DRAINAGE MiroMed Pfleiderer Medical Produkte GmbH Lindleystr. 12 60314 Frankfurt Internet: www.miromed.de E-Mail: mail@miromed.de Telefon (069) 489878-0 Telefax (069) 489878-70 FOLEY SILICONE BALLOON CATHETER WITH

More information

Ureteroscopy solutions for your most challenging cases.

Ureteroscopy solutions for your most challenging cases. Ureteroscopy solutions for your most challenging cases. IT TAKES INSIGHT TO SEE THAT NO TWO STONE PATIENTS ARE ALIKE. THAT S THE DIFFERENCE BETWEEN MAKING DEVICES AND MAKING PROGRESS. There is nothing

More information

Rüsch Urology Catalogue For Almost Every Application

Rüsch Urology Catalogue For Almost Every Application Rüsch Urology Catalogue For Almost Every Application Urology Colour Code, Tips and Material Information Transurethral Foley Catheters 02 Transurethral Foley Catheters. Standard 2-Way Drainage 03.2 Catheters

More information

DAll that you need to know

DAll that you need to know DAll that you need to know ouble - J Stenting D.Dalela UroHealth Education Cell UroHealth Research Centre, Lucknow What is a Double-J Stent? Double J (D.J.) Stent is a fine tube made of silicone coated

More information

BIOPSY GUN. Delivered in sterile peel-open package. Device is made of Stainless Steel and PP material.

BIOPSY GUN. Delivered in sterile peel-open package. Device is made of Stainless Steel and PP material. BIOPSY GUN Biopsy Gun is a reusable system for histological core biopsies. It has a throw (advancement) of 25mm and is used in conjunction with a single use needle. This device is used to obtain tissue

More information

High Flow Family. Short Term Dialysis Catheters. Dialysis

High Flow Family. Short Term Dialysis Catheters. Dialysis High Flow Family Short Term Dialysis Catheters Dialysis High Flow Triple Lumen 13.5 Fr Unique tip design, superior to the classic sidehole design: Clotting risk is considerably reduced Adhesion risk to

More information

Bacterial biofilm formation on urologic devices and heparin coating as preventive strategy

Bacterial biofilm formation on urologic devices and heparin coating as preventive strategy International Journal of Antimicrobial Agents 23S1 (2004) S67 S74 Bacterial biofilm formation on urologic devices and heparin coating as preventive strategy Peter Tenke a,, Claus R. Riedl b, Gwennan Ll.

More information

Bactiguard Infection Protection. BIP Foley Catheter. For prevention of healthcare associated infections

Bactiguard Infection Protection. BIP Foley Catheter. For prevention of healthcare associated infections Bactiguard Infection Protection BIP Foley Catheter For prevention of healthcare associated infections Bactiguard benefits Reduced healthcare costs Reduced use of antibiotics Save lives Catheter associated

More information

Having a Ureteric Stent What to expect and how to manage

Having a Ureteric Stent What to expect and how to manage Service: Urology Having a Ureteric Stent What to expect and how to manage Exceptional healthcare, personally delivered Introduction In patients who have, or might have, an obstruction (blockage) of the

More information

Caring for a Nephrostomy and what is Ureteric Stenting

Caring for a Nephrostomy and what is Ureteric Stenting Useful contacts: Macmillan Cancer Support Tel: 0808 808 00 00 www.macmillan.org.uk Buckinghamshire Healthcare NHS Trust Cancer Education, Information & Support Service Tel: 01296 316954 How can I help

More information

Bactiguard Infection Protection. BIP Foley Catheter. For prevention of healthcare associated infections

Bactiguard Infection Protection. BIP Foley Catheter. For prevention of healthcare associated infections Bactiguard Infection Protection BIP Foley Catheter For prevention of healthcare associated infections Bactiguard benefits Reduced healthcare costs Reduced use of antibiotics Save lives Catheter associated

More information

MP A Prospective Evaluation of the Catheter Science M3 Mini Catheter for Patients with Prostatic Obstruction. Gaines W. Hammond Jr.

MP A Prospective Evaluation of the Catheter Science M3 Mini Catheter for Patients with Prostatic Obstruction. Gaines W. Hammond Jr. MP73-06 - A Prospective Evaluation of the Catheter Science M3 Mini Catheter for Patients with Prostatic Obstruction Gaines W. Hammond Jr. MD FACS M3 Mini Catheter M3 Segmented M3 Plus Dynamic Wings M3

More information

DRAINAGE. MeritEMEA.com

DRAINAGE. MeritEMEA.com DRAINAGE MeritEMEA.com Thoracentesis Biliary Drainage Nephrostomy Paracentesis Abscess Drainage COMPLETE DRAINAGE SOLUTIONS Merit Medical offers an integrated suite of products designed to support your

More information

Biliary Metal Stents MAKING A DIFFERENCE TO HEALTH

Biliary Metal Stents MAKING A DIFFERENCE TO HEALTH Biliary Metal Stents In a fast paced and maturing market, Diagmed Healthcare s Hanarostent has managed to continue to innovate and add unique and clinically superior features to its already premium range.

More information

Urinary catheters - a matter of convenience? Aniruddha Chakravarti Consultant Urological Surgeon

Urinary catheters - a matter of convenience? Aniruddha Chakravarti Consultant Urological Surgeon Urinary catheters - a matter of convenience? Aniruddha Chakravarti Consultant Urological Surgeon Indications Any absolute? Relative Retention - ISC vs IDC? Incontinence - containment devices/drugs/nursing

More information

3. Urinary Catheters. Indications. Methods of Bladder Catheterization. Hashim Hashim

3. Urinary Catheters. Indications. Methods of Bladder Catheterization. Hashim Hashim 3. Urinary Catheters Hashim Hashim Indications Urinary catheters are used to drain urine from the bladder. The main indications are: A. Diagnostic Measure post-void residual in the absence of ultrasound

More information

Silver makes it better. Silicone makes it best. COMPLICATIONS RELIABILITY & FUNCTION COATINGS PRODUCT INFORMATION

Silver makes it better. Silicone makes it best. COMPLICATIONS RELIABILITY & FUNCTION COATINGS PRODUCT INFORMATION Silver makes it better. Silicone makes it best. COMPLICATIONS RELIABILITY & FUNCTION COATINGS PRODUCT INFORMATION COMPLICATIONS A BROAD-SPECTRUM REAL SOLUTION for catheter complications. Complications

More information

CATHETER SELECTION & CATHETERISATION

CATHETER SELECTION & CATHETERISATION CATHETER SELECTION & CATHETERISATION Wilma Nicolson BAUN Study Day 8 th May 2015 PRINCIPLES OF CARE NHS Quality Improvement Scotland Best Practice Statement Urinary Catheterisation & Catheter Care Continence

More information

QUALITY PRODUCTS FOR ALMOST EVERY APPLICATION

QUALITY PRODUCTS FOR ALMOST EVERY APPLICATION Care at home QUALITY PRODUCTS FOR ALMOST EVERY APPLICATION Catheters and urine collection bags for urinary drainage 2 introduction QUALITY UROLOGY PRODUCTS FOR ALMOST EVERY APPLICATION Comprehensive continence

More information

Mrs Maya Harris Consultant Urologist INDWELLING CATHETERS: COMPLICATIONS AND SOLUTIONS

Mrs Maya Harris Consultant Urologist INDWELLING CATHETERS: COMPLICATIONS AND SOLUTIONS Mrs Maya Harris Consultant Urologist INDWELLING CATHETERS: COMPLICATIONS AND SOLUTIONS AIMS OF PRESENTATION Discuss what can go wrong Discuss reducing risks Discuss managing troublesome problems and when

More information

Complication of long indwelling urinary catheter and stent COMPLICATION OF LONG INDWELLING URINARY CATHETER AND STENT

Complication of long indwelling urinary catheter and stent COMPLICATION OF LONG INDWELLING URINARY CATHETER AND STENT 151 COMPLICATION OF LONG INDWELLING URINARY CATHETER AND STENT Jain A 1 *, Srivastava R 1, Prasad A 1, Marwah K 1 1. Department of surgery, Subharti medical college, Meerut U.P. India Correspondence: Dr.

More information

DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS

DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS HALYARD* MIC* AND MIC-KEY* INTRODUCER KITS HALYARD* MIC* and MIC-KEY* Introducer Kits provide physicians with an innovative solution to facilitate the primary

More information

Cook Europe Shared Service Centre

Cook Europe Shared Service Centre www.cookmedical.com Cook Europe Shared Service Centre Country Telephone E-mail Austria (+43) 1-795-67-121 oeorders@cook.ie Belgium ench (+32) 27-00-16-33 beorders@cook.ie Belgium Flemish (+32) 27-00-16-33

More information

Versatility and Proven Safety

Versatility and Proven Safety Versatility and Proven Safety Indicated for: Temporary or Permanent placement Standard or Over-The-Wire Delivery Jugular, Femoral, Antecubital, and Popliteal Access > Proven Safety Initial Clinical Trial

More information

RÜSCH CLOSED URINE DRAINAGE SYSTEMS. For maximum protection against nosocomial urinary tract infections

RÜSCH CLOSED URINE DRAINAGE SYSTEMS. For maximum protection against nosocomial urinary tract infections RÜSCH CLOSED URINE DRAINAGE SYSTEMS For maximum protection against nosocomial urinary tract infections 2 introduction TELEFLEX S RÜSCH CLOSED URINE DRAINAGE SYSTEMS SIMPLE, SAFE AND HYGIENIC Trusted brands

More information

Objectives: To analyze various factors predicting success of retrograde ureteric stenting in managing patients with ureteric obstruction.

Objectives: To analyze various factors predicting success of retrograde ureteric stenting in managing patients with ureteric obstruction. ISPUB.COM The Internet Journal of Urology Volume 14 Number 1 Factors Predicting Success Rate Of Retrograde Ureteric Stenting In Managing Patients With Ureteric Obstruction- Our Experiences In A South Indian

More information

A Novel New Approach to Treatment of Catastrophic Urinary Dysfunction

A Novel New Approach to Treatment of Catastrophic Urinary Dysfunction A Novel New Approach to Treatment of Catastrophic Urinary Dysfunction John B. Devine II, M.D., FACOG 1,2, Stanley E. Rittgers, PhD (Ret.) 1,3, Michael D. Serene, M.D. (Ret.) 1,4 1 3D Urologic, LLC, Akron,

More information

What is the ICD 10 code for indwelling Foley catheter

What is the ICD 10 code for indwelling Foley catheter What is the ICD 10 code for indwelling Foley catheter 2018 ICD-10 code for Encounter for fitting and adjustment of urinary device is Z46.6. indwelling catheter - Z46.6 stent. Sep 6, 2017. Can someone to

More information

Key Definitions. Downloaded from

Key Definitions. Downloaded from Key Definitions In order to make sure that every member of the team is clear about the definitions that will be used, we have provided a list of key terms in the next few pages along with commonly used

More information

creating stability a bess group company Stents for Gastroenterology

creating stability a bess group company Stents for Gastroenterology a bess group company Stents for Gastroenterology a bess group company Page 2 CONTENTS aixstent self-expanding Nitinol stents aixstent OES Esophageal Stent... 6 aixstent OEL Esophageal Leakage Stent...

More information

Evidence Summary: The inflow Urinary Prosthesis FDA De Novo Approval DEN130044

Evidence Summary: The inflow Urinary Prosthesis FDA De Novo Approval DEN130044 Evidence Summary: The inflow Urinary Prosthesis FDA De Novo Approval DEN130044 Unique alternative to urinary catheters for women with permanent urinary retention Therapeutic benefits o Highly effective

More information

KIDNEY STONES. When to call for help Call these rooms if any of the following occur:

KIDNEY STONES. When to call for help Call these rooms if any of the following occur: KIDNEY STONES Background Kidney stones that move into the ureter (the narrow tube that drains each kidney) often cause a lot of pain. If the stones measure 5mm or less in diameter then most will eventually

More information

Guide Wires design and selection Abbott Vascular. All rights reserved.

Guide Wires design and selection Abbott Vascular. All rights reserved. Guide Wires design and selection the cardiac catheter was...the key in the lock Cournand AF, Nobel lecture December 11, 1956; nowadays, the coronary guidewire is the master key to all locks Colombo et

More information

Catheter-Associated Urinary Tract Infection (CAUTI) Event

Catheter-Associated Urinary Tract Infection (CAUTI) Event Device-associated Events Catheter-Associated Urinary Tract Infection () Event Introduction: The urinary tract is the most common site of healthcare-associated infection, accounting for more than 30% of

More information

Lisette Ramos-Voigt November 25, Kidney Stone Formation. substances found in the urine (Leslie & Swierzewski, 1998). There are various types of

Lisette Ramos-Voigt November 25, Kidney Stone Formation. substances found in the urine (Leslie & Swierzewski, 1998). There are various types of Lisette Ramos-Voigt November 25, 2008 Kidney Stone Formation Kidney stones are hard solid pieces of material that form in the kidneys out of substances found in the urine (Leslie & Swierzewski, 1998).

More information

BioCath for your temporary vascular access

BioCath for your temporary vascular access BioCath for your temporary vascular access MaxFlo and MaxFlo Slim Highflow Catheter Dual Lumen Catheter Single Lumen Catheter www.vascular-access.com BioCath MaxFlo and MaxFlo Slim MaxFlo Slim Catheter

More information

BIP Endotracheal Tube

BIP Endotracheal Tube Bactiguard Infection Protection BIP Endotracheal Tube For prevention of healthcare associated infections Ventilator associated pneumonia Infections of the respiratory tract are serious and common healthcare

More information

ANTIBIOTIC USE DURING ENDOUROLOGIC SURGERY

ANTIBIOTIC USE DURING ENDOUROLOGIC SURGERY ANTIBIOTIC USE DURING ENDOUROLOGIC SURGERY Comprehensive Kidney Stone Center at Duke University Medical Center Durham, North Carolina Glenn M. Preminger LEADING EDGE UROLOGY 49th Annual Duke Urologic Assembly

More information

Acute Therapy Systems. provencare Catheter Sets

Acute Therapy Systems. provencare Catheter Sets Acute Therapy Systems provencare Catheter Sets Catheter Sets Contents provencare Catheter Sets 4 provencare Product Features and Accessories 6 provencare Single Lumen Catheter Sets 8 provencare Paediatric

More information

MEDICAL EQUIPMENT. Program. 6 Ureteral Stents Specialities 9 Ureteral Stents hydrophilic

MEDICAL EQUIPMENT. Program. 6 Ureteral Stents Specialities 9 Ureteral Stents hydrophilic Program Page Article Urology 4 Ureteral Stents Standard 6 Ureteral Stents Specialities 9 Ureteral Stents hydrophilic 10 Ureteral Superstents Long Life 11 Ureteral Stents soft Loops 12 Steerable Stent Pusher

More information

Continuous Bladder Irrigation

Continuous Bladder Irrigation Continuous Bladder Irrigation Introduction Continuous bladder irrigation, or CBI, is the infusion of a sterile solution into the urinary bladder. The purpose of CBI is to prevent the formation of blood

More information

-vita THORACIC 3G. Stent Graft System SOLUTIONS FOR VASCULAR DISEASE

-vita THORACIC 3G. Stent Graft System SOLUTIONS FOR VASCULAR DISEASE Stent Graft SOLUTIONS FOR VASCULAR DISEASE 1 PURE PERFORMANCE AND QUALITY: STENT GRAFT SYSTEMS BY JOTEC JOTEC is an innovation-oriented company with consistent focus on its core competencies: the development

More information

Colonic Metal Stents MAKING A DIFFERENCE TO HEALTH

Colonic Metal Stents MAKING A DIFFERENCE TO HEALTH Colonic Metal Stents In a fast paced and maturing market, Diagmed Healthcare s Hanarostent has managed to continue to innovate and add unique and clinically superior features to its already premium range.

More information

Quick Reference Guide

Quick Reference Guide Quick Reference Guide Indications for Use The AFX Endovascular AAA System is indicated for endovascular treatment in patients with AAA. The devices are indicated for patients with suitable aneurysm morphology

More information

Recanalisation of urethral strictures with new-generation temporary covered biocompatible metal endoprostheses

Recanalisation of urethral strictures with new-generation temporary covered biocompatible metal endoprostheses Acta Chirurgica Iugoslavica (ACI) Vol: LIV, (3) 2007, pages 123-127 SCIENTIFIC PAPER UDC: 616.65-007.271-089.819.5 Recanalisation of urethral strictures with new-generation temporary covered biocompatible

More information

NEW INSTRUMENTS & DEVICES

NEW INSTRUMENTS & DEVICES NEW INSTRUMENTS & DEVICES Dalela Triple J Stent The commonly used Double J Stent causes a certain amount of dysuria and other storage LUTS because of trigonal irritation by lower coil of D J Stent. I have

More information

EverFlow Dolphin Protect Higher performance, better protection

EverFlow Dolphin Protect Higher performance, better protection EverFlow Dolphin Protect Higher performance, better protection Now available with Glid In bevel for an even smoother insertion EverFlow Dolphin Protect long-term hemodialysis catheter EverFlow Dolphin

More information

Cardiovascular Catalog

Cardiovascular Catalog Cardiovascular Catalog Table of Contents About Us 4 CORDIS Access Portfolio 5 AVANTI + Sheath Introducer 6 AVANTI + Mid-Length Sheath Introducer 7 AVANTI + Valveless Portless Sheath Introducer with Mini-Guidewire

More information

URETERAL OBSTRUCTION IN SMALL ANIMALS. Courtney Ikuta, DVM Department of Surgery VCA West Coast Specialty and Emergency Animal Hospital

URETERAL OBSTRUCTION IN SMALL ANIMALS. Courtney Ikuta, DVM Department of Surgery VCA West Coast Specialty and Emergency Animal Hospital URETERAL OBSTRUCTION IN SMALL ANIMALS Courtney Ikuta, DVM Department of Surgery VCA West Coast Specialty and Emergency Animal Hospital URETERAL OBSTRUCTION Vague history and clinical signs Difficult diagnosis

More information

Cystoscopy and insertion of a ureteric stent

Cystoscopy and insertion of a ureteric stent Cystoscopy and insertion of a ureteric stent Urology Department Patient Information Leaflet Introduction This leaflet is for people who have been recommended to have a procedure called cystoscopy and insertion

More information

DJ STENT PROCEDURE. What does the procedure involve? What are the alternatives to this procedure?

DJ STENT PROCEDURE. What does the procedure involve? What are the alternatives to this procedure? What does the procedure involve? DJ STENT PROCEDURE Telescopic inspection of the bladder and urethra combined with insertion, removal or changing of a soft plastic tube placed between the kidney and the

More information

Indwelling pleural drainage system explained

Indwelling pleural drainage system explained Indwelling pleural drainage system explained Respiratory Medicine Patient Information Leaflet Introduction This leaflet is about the procedure to fit an indwelling drainage system. It tells you what the

More information

Antegrade ureteric stent insertion Patient information

Antegrade ureteric stent insertion Patient information Antegrade ureteric stent insertion Patient information This leaflet tells you about having antegrade ureteric stenting. It explains what is involved and what the possible risks are. It is not meant to

More information

Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family

Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family MICRO-INTRODUCERS Micro-Introducer Kits Galt s Micro-Introducer Kits with smooth transition,

More information

Catheter-Associated Urinary Tract Infection (CAUTI) Event

Catheter-Associated Urinary Tract Infection (CAUTI) Event Catheter-Associated Urinary Tract Infection () Event Introduction: The urinary tract is the most common site of healthcare-associated infection, accounting for more than 30% of infections reported by acute

More information

CATHETER-ASSOCIATED URINARY TRACT INFECTIONS

CATHETER-ASSOCIATED URINARY TRACT INFECTIONS CATHETER-ASSOCIATED URINARY TRACT INFECTIONS Hamid Emadi M.D Associate professor of Infectious diseases Department Tehran university of medical science The most common nosocomial infection The urinary

More information

Novatech Products for Interventional Pulmonology

Novatech Products for Interventional Pulmonology Novatech Products for Novatech and Boston Medical Products Bringing you the finest products for Novatech is a manufacturer of top-quality medical products used successfully worldwide in the growing specialty

More information

Imaging of double J ureteral stents - what to look for?

Imaging of double J ureteral stents - what to look for? Imaging of double J ureteral stents - what to look for? Poster No.: C-1181 Congress: ECR 2014 Type: Educational Exhibit Authors: V. Urban, M. Djosev, J. Ilic, G. Lukic, T. Nastasic, S. M. 1 2 1 1 3 1 3

More information

For more than 2,500 years urinary catheters have been

For more than 2,500 years urinary catheters have been Diamond-Like Carbon Coatings on Ureteral Stents A New Strategy for Decreasing the Formation of Crystalline Bacterial Biofilms? Norbert Laube,* Lisa Kleinen, Jörg Bradenahl and Andreas Meissner From the

More information

New Devices Pedro Pinto Cardoso

New Devices Pedro Pinto Cardoso New Devices Pedro Pinto Cardoso HSM, CHLN, CALM for CTOs Guidewires Microcatheters Radiofrequency Pharmacotherapy Pedro Pinto Cardoso, Serviço de Cardiologia HSM CHLN New Guidewires SENTAI family Samurai

More information

Unit Title: Urinary Catheterisation

Unit Title: Urinary Catheterisation Unit Credit Value: 3 Unit Level: Three Unit Guided Learning Hours: 21 Ofqual Unit Reference Number: M/505/7684 Unit Review Date: 31/10/2018 Unit Sector: 1.2 Nursing and Subjects and Vocations Allied to

More information

MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES

MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES PUSHING BOUNDARIES Terumo Interventional Systems is committed to your success with innovative procedural solutions and ongoing support for your most challenging

More information

Times have have changed... you? OptiFlo IRRIGATION SOLUTION. Foley Catheter Maintenance Solutions

Times have have changed... you? OptiFlo IRRIGATION SOLUTION. Foley Catheter Maintenance Solutions Times have have changed... you? OptiFlo Foley Catheter Maintenance Solutions Contents 1. Introduction Causes of Catheter Blockage 2. Recurrent Blockage Causes of Encrustation 3. Investigating Encrustation

More information

Managing your bladder with a Supra-pubic catheter at home

Managing your bladder with a Supra-pubic catheter at home Managing your bladder with a Supra-pubic catheter at home Providing a range of NHS services in Gateshead, South Tyneside and Sunderland. Managing your bladder with a Supra-pubic catheter at home The purpose

More information

BARD LATEX FOLEY CATHETERS. Together, advancing the world of health. Utilization. Insertion. Maintenance. Duration

BARD LATEX FOLEY CATHETERS. Together, advancing the world of health. Utilization. Insertion. Maintenance. Duration BARD LATEX FOLEY CATHETERS Utilization Insertion Maintenance Duration Together, advancing the world of health LATEX ALLERGIES ARE NOT NEW Approximately 1% of the U.S. population is estimated to be at risk

More information

Indwelling Urinary Catheters And Drainage systems

Indwelling Urinary Catheters And Drainage systems If you require this leaflet in any other format, e.g., large print, please telephone 01935 384256 Indwelling Urinary Catheters And Drainage systems Useful organisations Ms Society Helpline Tel: 0808 800

More information

Gastric / EUS Metal Stents

Gastric / EUS Metal Stents Gastric / EUS Metal Stents In a fast paced and maturing market, Diagmed Healthcare s Hanarostent has managed to continue to innovate and add unique and clinically superior features to its already premium

More information

Patient information leaflet. Royal Surrey County Hospital. NHS Foundation Trust. Nephrostomy. Radiology

Patient information leaflet. Royal Surrey County Hospital. NHS Foundation Trust. Nephrostomy. Radiology Patient information leaflet Royal Surrey County Hospital NHS Foundation Trust Nephrostomy Radiology This leaflet informs you about the procedure known as a nephrostomy. It explains what is involved and

More information

Catheter-Associated Urinary Tract Infection (CAUTI) Event

Catheter-Associated Urinary Tract Infection (CAUTI) Event Catheter-Associated Urinary Tract Infection () Event Introduction: Urinary tract infections (UTIs) are tied with pneumonia as the second most common type of healthcare-associated infection, second only

More information

A Patients Guide to Caring for a Nephrostom y Tube at Home

A Patients Guide to Caring for a Nephrostom y Tube at Home Department of Urology The Urinary S ystem A Patients Guide to Caring for a Nephrostom y Tube at Home The urinary system is made up of several different parts including the kidneys, ureters, the bladder

More information

90% of bladder tumours are transitional cell carcinoma (TCC), the remaining 10% of cases are squamous cell carcinoma, adenocarcinoma and sarcoma.

90% of bladder tumours are transitional cell carcinoma (TCC), the remaining 10% of cases are squamous cell carcinoma, adenocarcinoma and sarcoma. The Role of the Interventional Radiologist in Management of Post-Radical Cystectomy Ureteral Obstruction : A Case Review of Retrograde Transileal Conduit Ureteric Stents. Poster No.: C-2288 Congress: ECR

More information

Steerable Antegrade Stenting: A New Trick of the Trade

Steerable Antegrade Stenting: A New Trick of the Trade Surgical Technique Steerable Antegrade Stenting International Braz J Urol Vol. 33 (3): 389-394, May - June, 2007 Steerable Antegrade Stenting: A New Trick of the Trade Udo Nagele, Aristotelis G. Anastasiadis,

More information

Zenith Alpha T HORACIC ENDOVASCULAR GRAFT

Zenith Alpha T HORACIC ENDOVASCULAR GRAFT Deployment Sequence Zenith Alpha T HORACIC ENDOVASCULAR GRAFT www.cookmedical.com AI-D21183-EN-F Preparation and flush Proximal and distal components Remove the yellow hubbed inner stylet from the dilator

More information

THE THE MORE MORE NATURAL APPROACH TO OPTIMAL FIT

THE THE MORE MORE NATURAL APPROACH TO OPTIMAL FIT THE THE MORE MORE NATURAL APPROACH Natural Approach TO Optimal Fit TO OPTIMAL FIT Conformability without Compromise THE STANDARD IN Conformability AND Designed for flexibility and conformability in tortuous

More information

Ureteral Stenting and Nephrostomy

Ureteral Stenting and Nephrostomy Scan for mobile link. Ureteral Stenting and Nephrostomy Ureteral stenting and nephrostomy help restore urine flow through blocked ureters and return the kidney to normal function. Ureters are long, narrow

More information

Hydrophilic Coating - Living tissue interaction

Hydrophilic Coating - Living tissue interaction Tailoring polymer friction, wear and hydrophilic lubricity of intermittent catheters Page 1 Content Introduction to hydrophilic coating technology Development and applications of hydrophilic coatings on

More information

Surveillance will occur in all inpatient locations in Kuwait Ministry of Health hospitals.

Surveillance will occur in all inpatient locations in Kuwait Ministry of Health hospitals. Urinary Tract Infection (Catheter-Associated Urinary Tract Infection [CAUTI] Non-Catheter-Associated Urinary Tract Infection [UTI]) Other Urinary System Infection [USI]) Events Settings: Surveillance will

More information

Indwelling urinary catheter

Indwelling urinary catheter Indwelling urinary catheter Information for patients and carers RDaSH leading the way with care What is a catheter? A catheter is a hollow flexible tube designed to drain urine from the bladder. Following

More information

Second-line Treatment for OAB

Second-line Treatment for OAB Patient Information English 35 Second-line Treatment for OAB The underlined terms are listed in the glossary. Sometimes the drugs your doctor prescribed do not improve your overactive symptoms (OAB). In

More information

Endoscopic Ultrasound Endoskopischer Ultraschall

Endoscopic Ultrasound Endoskopischer Ultraschall Endoscopic Ultrasound Endoskopischer Ultraschall SonoTip Pro Control Endoscopic Ultrasound-Guided FNA System Single Use Twist-Lock Technology for Sheath & Needle Length Adjustments Offering Physician Controlled

More information

Continence Control System USER S MANUAL

Continence Control System USER S MANUAL Continence Control System USER S MANUAL Continence Control System User's Manual Caution: Read this user s manual completely before using this system Causes of Incontinence Causes are many and varied. Most

More information

Antegrade ureteric stent

Antegrade ureteric stent All of our publications are available in different languages, larger print, braille (English only), audio tape or another format of your choice. Tha gach sgrìobhainn againn rim faotainn ann an diofar chànanan,

More information

Nephrostomy. Radiology Department. Patient information leaflet

Nephrostomy. Radiology Department. Patient information leaflet Nephrostomy Radiology Department Patient information leaflet This leaflet informs you about the procedure known as a nephrostomy. It explains what is involved and the possible risks. The benefits and risks

More information

+91-8048764958 Nidhi Meditech Systems http://www.nidhiurologyproducts.com/ We are an ISO 13485:2003, WHO-GMP & CE certified Manufacturer, Supplier and Exporter in Urological Equipment & Instrument. These

More information

Subcutaneous pyelovesical bypass Detour bypass as a solution for ureteric obstruction

Subcutaneous pyelovesical bypass Detour bypass as a solution for ureteric obstruction 429 O R I G I N A L P A P E R TRAUMA AND RECONSTRUCTIVE UROLOGY Subcutaneous pyelovesical bypass Detour bypass as a solution for ureteric obstruction Andrzej Jerzy Wrona, Jarosław Zgajewski, Norbert Kopeć,

More information

ISO INTERNATIONAL STANDARD. Sterile single-use intravascular catheter introducers

ISO INTERNATIONAL STANDARD. Sterile single-use intravascular catheter introducers INTERNATIONAL STANDARD ISO 11070 First edition 1998-05-01 Sterile single-use intravascular catheter introducers Introducteurs de cathéters intravasculaires stériles, non réutilisables A Reference number

More information

Antegrade ureteric stent

Antegrade ureteric stent Antegrade ureteric stent Information for you Follow us on Twitter @NHSaaa Find us on Facebook at www.facebook.com/nhsaaa Visit our website: www.nhsaaa.net All our publications are available in other formats

More information

Biomaterials in the Urinary Tract: New Concepts

Biomaterials in the Urinary Tract: New Concepts Biomaterials in the Urinary Tract: New Concepts Ben H. Chew, MD, MSc, FRCSC Endourology & Laparoscopy Fellow The University of Western Ontario London, Canada 1. Ureteral Stent Encrustation 2. Stent-related

More information

Having a Ureteric Stent: What to expect and how to manage

Having a Ureteric Stent: What to expect and how to manage Having a Ureteric Stent: What to expect and how to manage This leaflet explains: In patients who have, or might have, an obstruction (blockage) of the kidney, an internal drainage tube called a stent is

More information

Abutments for all indications. Individualized CAD/CAM and prefabricated implant restorations

Abutments for all indications. Individualized CAD/CAM and prefabricated implant restorations Abutments for all indications. Individualized CAD/CAM and prefabricated implant restorations 2 Abutments for all indications Comprehensive and effective the Nobel Biocare abutment portfolio. The Nobel

More information

Two cases of retained ureteral stents presenting with breakage and encrustations

Two cases of retained ureteral stents presenting with breakage and encrustations Available online at www.ijmrhs.com ISSN No: 2319-5886 International Journal of Medical Research & Health Sciences, 2016, 5, 10:208-212 Two cases of retained ureteral stents presenting with breakage and

More information

Designed to Reduce the Risk of Occlusion (1)

Designed to Reduce the Risk of Occlusion (1) Designed to Reduce the Risk of Occlusion (1) more efficient flushing better outcomes The Vortex* ports feature the Vortex Technology for a more efficient flushing. The Vortex Technology sets up efficient

More information

Angioplasty Summit TCTAP Technical Aspects of Overview in CTO-PCI Toyohashi Heart Center Takahiko Suzuki, M.D

Angioplasty Summit TCTAP Technical Aspects of Overview in CTO-PCI Toyohashi Heart Center Takahiko Suzuki, M.D Angioplasty Summit TCTAP 2010 Technical Aspects of Overview in CTO-PCI Toyohashi Heart Center Takahiko Suzuki, M.D Introduction CTO-PCI has been technically and technologically evolved over the past two

More information

Measurement of Mechanical Properties of Coronary Stents according to the European Standard pren

Measurement of Mechanical Properties of Coronary Stents according to the European Standard pren February 1999 45 Measurement of Mechanical Properties of Coronary Stents according to the European Standard pren 12006-3 W. SCHMIDT, P. BEHRENS, D. BEHREND, K.-P. SCHMITZ Institute for Biomedical Engineering,

More information

United States Patent (19)

United States Patent (19) United States Patent (19) Goldberg et al. (54) URETERAL STENTSYSTEM 75 Inventors: Jay R. Goldberg, Northbrook, Ill.; Donald V. Hillegass, Franksville, Wis. 73) Assignee: Medical Engineering Corporation,

More information

NIRxcell CoCr Coronary Stent System

NIRxcell CoCr Coronary Stent System cordis.com/nirxcell NIRxcell CoCr Coronary Stent System Exceptional Outcomes by Design Exceptionally low TLR rate of 5.1 % at 9 months 1 Superior Deliverability and Crossability 2 Best-in-class Conformability

More information