- Adrian Jenkins
- 6 years ago
- Views:
Transcription
1
2 Yellow-Star Tumor-Stent Double-J Ureteral Stents-Set PC-coated Set Components YELLOW-STAR Tumor-Stent pusher guide wire Ureteral Stent Polyurethane (PUR) PC coating to minimise risk of infection and encrustation, resulting in extended indwelling time Pressure resistant shaft, without drainage openings for preventing ingrowth of tumor tissue Soft pigtails for better wearing comfort Drainage openings only in pigtails Open tip Markings for exact positioning Radiopaque Pusher Length: 40 cm Hydrophilic coating for better gliding ability prior to application, guide wire must be moistened in dispenser 1.1
3 Yellow-Star Tumor-Stent Double-J Ureteral Stents-Set PC-coated Open tip Size (FR/CH) Length (cm) without with Length (cm) Diameter Tip Stiffness 0 22 TU TU straight standard 0 24 TU TU straight standard 0 2 TU-4102 TU straight standard 0 28 TU TU straight standard 0 30 TU TU straight standard 0 32 TU TU straight standard TU TU straight standard TU TU straight standard 07 2 TU TU straight standard TU TU straight standard TU TU straight standard TU TU straight standard TU TU straight standard TU TU straight standard 08 2 TU TU straight standard TU TU straight standard TU TU straight standard TU TU straight standard 1.1
4 YELLOW-STAR Tumor-Stent Double-J Ureteral Stents-Set PC-coated, steerable Set Components YELLOW-STAR Tumor-Stent steering device guide wire Ureteral Stent Polyurethane (PUR) PC coating to minimise risk of infection and encrustation, resulting in extended indwelling time Pressure resistant shaft, without drainage openings for preventing ingrowth of tumor tissue Soft pigtails for better wearing comfort Drainage openings only in pigtails Open tip Markings for exact positioning Radiopaque Steering Device Pusher Disconnector Length: 53 cm Hydrophilic coating for better gliding ability prior to application, guide wire must be moistened in dispenser 1.17
5 YELLOW-STAR Tumor-Stent Double-J Ureteral Stents-Set PC-coated, steerable Open tip Size (FR/CH) Length (cm) without with Length (cm) Diameter Tip Stiffness 0 22 TU TU straight standard 0 24 TU TU straight standard 0 2 TU-4702 TU straight standard 0 28 TU TU straight standard 0 30 TU TU straight standard 0 32 TU TU straight standard TU TU straight standard TU TU straight standard 07 2 TU TU straight standard TU TU straight standard TU TU straight standard TU TU straight standard TU TU straight standard TU TU straight standard 08 2 TU TU straight standard TU TU straight standard TU TU straight standard TU TU straight standard 1.17
6 Yellow-Star Tumor-Stent Double-J Ureteral Stent-Set PC-coated, steerable with coupling Set Components YELLOW-STAR Tumor-Stent steering device with coupling guide wire Ureteral Stent Polyurethane (PUR) PC coating to minimise risk of infection and encrustation, resulting in extended indwelling time Pressure resistant shaft, without drainage openings for preventing ingrowth of tumor tissue Soft pigtails for better wearing comfort Drainage openings only in pigtails Open tip Markings for exact positioning Radiopaque Steering Device with Coupling Pusher Disconnector Coupling to fasten guide wire Length: 43 cm Hydrophilic coating for better gliding ability prior to application, guide wire must be moistened in dispenser 1.18
7 Ureteral Stents Introduction and general information Introduction On the following pages, we would like to provide you with a comprehensive portfolio of our ureteral stents. Regardless of the indication, you are sure to find the appropriate product here. Material Polyurethane (PUR) All UROTECH ureteral stents are produced from aliphatic polyurethane (PUR) that has been specifically developed for medical applications. Unlike other materials, PUR shows minimal adhesion to blood cells and has a very low-grade inflammatory effect on tissue due to its physical and chemical properties. PUR becomes soft in a moist environment at body temperature, significantly limiting the risks of traumatic injury to surrounding tissue. Experimental tests and practical experience have shown that PUR is one of the least thrombogenic and most tissuecompatible materials for implantable medical products. Indwelling time All UROTECH ureteral stents are approved for long-term use and can remain inside a patient for several months. The additional layer of phosphorylcholine (PC) on the ureteral stents significantly reduces the risk of encrustation and infection. However, due to the heterogeneity of indications and individual differences between patients, regular follow-up examinations should be performed by the treating physician. Length measurements In accordance with international norms (ASTMF-1828), the length of our ureteral stents is always indicated without including the J-tip this equals the shaft length (Fig. 1). Variations In addition to our large catalog of standard ureteral stents, you can order many different custom variations based on your clinical needs. E.g. stents: with attached suture without drainage openings in shaft Fig. 1 bladder end length specification of all double-j ureteral stents (without pigtails) kidney end bladder side kidney side 1.1 (1) Referenzen: Russel JC.; Bacteria, Biofilm and Devices: The Possible Protective Role of Phosphorylcholine Materials; J. Endourology 2000; 14(1): Stickler DJ, Evans A. et al.; Strategies for the control of catheter encrustation; Int. J. of Antimicrobial Agents 2002; 19(): Heidenreich A., Becker T. et al.; Morbidity of internal Ureteral Stents: Prospective randomized Trial of Polyurethane versus Phosphorylcholine Coated Stents; Poster # 139 XVIIth Congress of European Association of Urology (EAU) Birmingham 2002
8 Yellow-Star Tumor-Stent Double-J Ureteral Stent-Set PC-coated, steerable with coupling Open tip Size (FR/CH) Length (cm) without with Length (cm) Diameter Tip Stiffness 0 22 TU TU straight standard 0 24 TU TU straight standard 0 2 TU-5702 TU straight standard 0 28 TU TU straight standard 0 30 TU TU straight standard 0 32 TU TU straight standard TU TU straight standard TU TU straight standard 07 2 TU TU straight standard TU TU straight standard TU TU straight standard TU TU straight standard TU TU straight standard TU TU straight standard 08 2 TU TU straight standard TU TU straight standard TU TU straight standard TU TU straight standard 1.18
9 PHOSPHORYLCHOLINE COATING UROTECH the worldwide only Manufacturer of PC coated Urological Devices More than 10 years Phosphorylcholine coating Phosphorylcholine is a biocompatible and durable sealing of the inner and outer surface of implants to prevent biofi lm formation and subsequent encrustation. It is successfully used not only in urology but also in other medical fi elds (coronary stents, contact lenses). Since 10 years now UROTECH is successfully using Phosphorylcholine coating (PC) on urological devices. Phosphorylcholine verifi ably lowers the risk of encrustations and infections, which results in prolonging the indwelling time of ureteral stents and nephrostomy catheters. The PC coated surfaces show, independent from the material, signifi cant less adsorptions of bacteria. As a result Phosphorylcholine is highly suitable for urological applications. a. b. Cross-section of a catheter after three month implantation in the same patient a. uncoated b. PC coated Phosphorylcholine coated ureteral stents minimize significant stent associated morbidity frequency of urinary tract infections cost for accompanying medication (anticholinergics, antibiotics) 4
10 The Effect is comparable to the camoufl age protection of a chameleon. Chameleons change colour in response to changes in light, or temperature thus protecting itselves from enemies by adopting visually to its surroundings. PC coated ureteral stents use an intelligent thermal and biological camoufl age effect sealing its surface against any environmental infl uences. For devices implanted in the urinary tract, encrustation of the implant`s surface is the most common technical problem. The camouflage effect of PC coated stents Even a short time after implantation a biofi lm formation on the surface of catheters is observed, containing multiple microorganism and extracellular matrices. This biofi lm can be seen as a permanent reservoir of these bacteria, protecting them against antibiotic therapy and maintaining a catheter associated urinary tract infection (CAUTI). Most of these microorganism are forming ureasplitting enzymes (urease) resulting in an increasing ph-level of urine and in the biofi lm. If the ph-level exceeds the neutral point (ph=7), different soluted molecules precipitate and cristalize on the surface of the implant. An encrustation is formed, the inner lumen of the catheter narrows and the implant doesn t function anymore. Phosphorylcholine coating keeps the ph level on the stent surface constant which minimizes the cristalization of molecules leading to a signifi cantly lower incrustation rate. Various clinical studies exist proving the effectiveness of Phosphorylcholine`s capacity of increasing the maximum indwelling time of ureteral stents. 5 VERTELLUS BIOMATERIALS PC is a trademark of Vertellus Specialties UK, Limited, all rights reserved.
Ureteral Stent. Pusher. Guide Wire. Clamp
YELLOW-STAR Ureteral Stents YELLOW-STAR Double-J Ureteral Stents-Set PC-coated Set Components YELLOW-STAR pusher guide wire Ureteral Stent Polyurethane (PUR) PC coating to minimise risk of infection and
More informationEndosil Silicone Double Loop Ureteral Stent
Endosil Silicone Double Loop Ureteral Stent B B Indwelling Up to 12 month ENDOUROLOGY C F B Soft Silicone C Better Tolerance for the patient R R RR Prevent risk of Migration ProductsCatalogue.EN.2.3 17
More informationCatheters and Wires. Dr. Vaibhav Jain MD,DNB,MNAMS Senior Consultant, IR Medanta, the Medicity, Gurgaon
Catheters and Wires Dr. Vaibhav Jain MD,DNB,MNAMS Senior Consultant, IR Medanta, the Medicity, Gurgaon Guidewires: Guidewires (solid wires navigated within the vascular system / extravascular tract) act
More informationContributor contact details
Contributor contact details Preface Fundamentals p. 1 Introduction to biofilms in urology p. 3 Introduction p. 3 What is a biofilm and why do they form? p. 4 Biofilm formation and structure p. 5 p. xv
More informationS I L I CONE BALLOON CATHETER. 98en TRANSURETHRAL BLADDER DRAINAGE
MiroMed Pfleiderer Medical Produkte GmbH Lindleystr. 12 60314 Frankfurt Internet: www.miromed.de E-Mail: mail@miromed.de Telefon (069) 489878-0 Telefax (069) 489878-70 FOLEY SILICONE BALLOON CATHETER WITH
More informationBactiguard Infection Protection. BIP Foley Catheter. For prevention of healthcare associated infections
Bactiguard Infection Protection BIP Foley Catheter For prevention of healthcare associated infections Bactiguard benefits Reduced healthcare costs Reduced use of antibiotics Save lives Catheter associated
More informationBactiguard Infection Protection. BIP Foley Catheter. For prevention of healthcare associated infections
Bactiguard Infection Protection BIP Foley Catheter For prevention of healthcare associated infections Bactiguard benefits Reduced healthcare costs Reduced use of antibiotics Save lives Catheter associated
More informationRüsch Urology Catalogue For Almost Every Application
Rüsch Urology Catalogue For Almost Every Application Urology Colour Code, Tips and Material Information Transurethral Foley Catheters 02 Transurethral Foley Catheters. Standard 2-Way Drainage 03.2 Catheters
More informationUreteroscopy solutions for your most challenging cases.
Ureteroscopy solutions for your most challenging cases. IT TAKES INSIGHT TO SEE THAT NO TWO STONE PATIENTS ARE ALIKE. THAT S THE DIFFERENCE BETWEEN MAKING DEVICES AND MAKING PROGRESS. There is nothing
More informationMP A Prospective Evaluation of the Catheter Science M3 Mini Catheter for Patients with Prostatic Obstruction. Gaines W. Hammond Jr.
MP73-06 - A Prospective Evaluation of the Catheter Science M3 Mini Catheter for Patients with Prostatic Obstruction Gaines W. Hammond Jr. MD FACS M3 Mini Catheter M3 Segmented M3 Plus Dynamic Wings M3
More informationBacterial biofilm formation on urologic devices and heparin coating as preventive strategy
International Journal of Antimicrobial Agents 23S1 (2004) S67 S74 Bacterial biofilm formation on urologic devices and heparin coating as preventive strategy Peter Tenke a,, Claus R. Riedl b, Gwennan Ll.
More informationHigh Flow Family. Short Term Dialysis Catheters. Dialysis
High Flow Family Short Term Dialysis Catheters Dialysis High Flow Triple Lumen 13.5 Fr Unique tip design, superior to the classic sidehole design: Clotting risk is considerably reduced Adhesion risk to
More informationDAll that you need to know
DAll that you need to know ouble - J Stenting D.Dalela UroHealth Education Cell UroHealth Research Centre, Lucknow What is a Double-J Stent? Double J (D.J.) Stent is a fine tube made of silicone coated
More informationBiliary Metal Stents MAKING A DIFFERENCE TO HEALTH
Biliary Metal Stents In a fast paced and maturing market, Diagmed Healthcare s Hanarostent has managed to continue to innovate and add unique and clinically superior features to its already premium range.
More informationMAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES
MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES PUSHING BOUNDARIES Terumo Interventional Systems is committed to your success with innovative procedural solutions and ongoing support for your most challenging
More informationUrinary catheters - a matter of convenience? Aniruddha Chakravarti Consultant Urological Surgeon
Urinary catheters - a matter of convenience? Aniruddha Chakravarti Consultant Urological Surgeon Indications Any absolute? Relative Retention - ISC vs IDC? Incontinence - containment devices/drugs/nursing
More informationUrological Products PRODUCT CATALOG ONE FOCUS, ONE MISSION: improving lives
Urological Products PRODUCT CATALOG ONE FOCUS, ONE MISSION: improving lives PRODUCTS FOR A greater well-being Rochester Medical is at the forefront of innovation and design of 100% silicone urological
More informationSilver makes it better. Silicone makes it best. COMPLICATIONS RELIABILITY & FUNCTION COATINGS PRODUCT INFORMATION
Silver makes it better. Silicone makes it best. COMPLICATIONS RELIABILITY & FUNCTION COATINGS PRODUCT INFORMATION COMPLICATIONS A BROAD-SPECTRUM REAL SOLUTION for catheter complications. Complications
More informationCaring for a Nephrostomy and what is Ureteric Stenting
Useful contacts: Macmillan Cancer Support Tel: 0808 808 00 00 www.macmillan.org.uk Buckinghamshire Healthcare NHS Trust Cancer Education, Information & Support Service Tel: 01296 316954 How can I help
More informationColonic Metal Stents MAKING A DIFFERENCE TO HEALTH
Colonic Metal Stents In a fast paced and maturing market, Diagmed Healthcare s Hanarostent has managed to continue to innovate and add unique and clinically superior features to its already premium range.
More informationCATHETER SELECTION & CATHETERISATION
CATHETER SELECTION & CATHETERISATION Wilma Nicolson BAUN Study Day 8 th May 2015 PRINCIPLES OF CARE NHS Quality Improvement Scotland Best Practice Statement Urinary Catheterisation & Catheter Care Continence
More informationDRAINAGE. MeritEMEA.com
DRAINAGE MeritEMEA.com Thoracentesis Biliary Drainage Nephrostomy Paracentesis Abscess Drainage COMPLETE DRAINAGE SOLUTIONS Merit Medical offers an integrated suite of products designed to support your
More informationQUALITY PRODUCTS FOR ALMOST EVERY APPLICATION
Care at home QUALITY PRODUCTS FOR ALMOST EVERY APPLICATION Catheters and urine collection bags for urinary drainage 2 introduction QUALITY UROLOGY PRODUCTS FOR ALMOST EVERY APPLICATION Comprehensive continence
More information3. Urinary Catheters. Indications. Methods of Bladder Catheterization. Hashim Hashim
3. Urinary Catheters Hashim Hashim Indications Urinary catheters are used to drain urine from the bladder. The main indications are: A. Diagnostic Measure post-void residual in the absence of ultrasound
More informationObjectives: To analyze various factors predicting success of retrograde ureteric stenting in managing patients with ureteric obstruction.
ISPUB.COM The Internet Journal of Urology Volume 14 Number 1 Factors Predicting Success Rate Of Retrograde Ureteric Stenting In Managing Patients With Ureteric Obstruction- Our Experiences In A South Indian
More informationHydrophilic Coating - Living tissue interaction
Tailoring polymer friction, wear and hydrophilic lubricity of intermittent catheters Page 1 Content Introduction to hydrophilic coating technology Development and applications of hydrophilic coatings on
More informationURETERAL OBSTRUCTION IN SMALL ANIMALS. Courtney Ikuta, DVM Department of Surgery VCA West Coast Specialty and Emergency Animal Hospital
URETERAL OBSTRUCTION IN SMALL ANIMALS Courtney Ikuta, DVM Department of Surgery VCA West Coast Specialty and Emergency Animal Hospital URETERAL OBSTRUCTION Vague history and clinical signs Difficult diagnosis
More informationMrs Maya Harris Consultant Urologist INDWELLING CATHETERS: COMPLICATIONS AND SOLUTIONS
Mrs Maya Harris Consultant Urologist INDWELLING CATHETERS: COMPLICATIONS AND SOLUTIONS AIMS OF PRESENTATION Discuss what can go wrong Discuss reducing risks Discuss managing troublesome problems and when
More informationDesigned to offer choices that empower life. Relative Recovery of Staphylococcus aureus. Intermittent Catheter 3. Intermittent Catheter 2
Advance Plus Catheters Designed to offer choices that empower life. Developed with life s details in mind, Advance and Advance Plus intermittent catheters provide the choices that help people manage continence
More informationMEDICAL EQUIPMENT. Program. 6 Ureteral Stents Specialities 9 Ureteral Stents hydrophilic
Program Page Article Urology 4 Ureteral Stents Standard 6 Ureteral Stents Specialities 9 Ureteral Stents hydrophilic 10 Ureteral Superstents Long Life 11 Ureteral Stents soft Loops 12 Steerable Stent Pusher
More informationEverFlow Dolphin Protect Higher performance, better protection
EverFlow Dolphin Protect Higher performance, better protection Now available with Glid In bevel for an even smoother insertion EverFlow Dolphin Protect long-term hemodialysis catheter EverFlow Dolphin
More informationComplication of long indwelling urinary catheter and stent COMPLICATION OF LONG INDWELLING URINARY CATHETER AND STENT
151 COMPLICATION OF LONG INDWELLING URINARY CATHETER AND STENT Jain A 1 *, Srivastava R 1, Prasad A 1, Marwah K 1 1. Department of surgery, Subharti medical college, Meerut U.P. India Correspondence: Dr.
More informationCook Europe Shared Service Centre
www.cookmedical.com Cook Europe Shared Service Centre Country Telephone E-mail Austria (+43) 1-795-67-121 oeorders@cook.ie Belgium ench (+32) 27-00-16-33 beorders@cook.ie Belgium Flemish (+32) 27-00-16-33
More informationUreteral Stenting and Nephrostomy
Scan for mobile link. Ureteral Stenting and Nephrostomy Ureteral stenting and nephrostomy help restore urine flow through blocked ureters and return the kidney to normal function. Ureters are long, narrow
More informationTimes have have changed... you? OptiFlo IRRIGATION SOLUTION. Foley Catheter Maintenance Solutions
Times have have changed... you? OptiFlo Foley Catheter Maintenance Solutions Contents 1. Introduction Causes of Catheter Blockage 2. Recurrent Blockage Causes of Encrustation 3. Investigating Encrustation
More informationDIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS
DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS HALYARD* MIC* AND MIC-KEY* INTRODUCER KITS HALYARD* MIC* and MIC-KEY* Introducer Kits provide physicians with an innovative solution to facilitate the primary
More informationcreating stability a bess group company Stents for Gastroenterology
a bess group company Stents for Gastroenterology a bess group company Page 2 CONTENTS aixstent self-expanding Nitinol stents aixstent OES Esophageal Stent... 6 aixstent OEL Esophageal Leakage Stent...
More informationBIOPSY GUN. Delivered in sterile peel-open package. Device is made of Stainless Steel and PP material.
BIOPSY GUN Biopsy Gun is a reusable system for histological core biopsies. It has a throw (advancement) of 25mm and is used in conjunction with a single use needle. This device is used to obtain tissue
More informationLoFric catheters: PROVING THEMSELVES DAY IN, DAY OUT. wellspect.com
LoFric catheters: PROVING THEMSELVES DAY IN, DAY OUT wellspect.com LoFric catheters proven over time Introduced in 1983, LoFric was the world s first hydrophilic urinary catheter for clean intermittent
More informationUnit Title: Urinary Catheterisation
Unit Credit Value: 3 Unit Level: Three Unit Guided Learning Hours: 21 Ofqual Unit Reference Number: M/505/7684 Unit Review Date: 31/10/2018 Unit Sector: 1.2 Nursing and Subjects and Vocations Allied to
More informationGalt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family
Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family MICRO-INTRODUCERS Micro-Introducer Kits Galt s Micro-Introducer Kits with smooth transition,
More informationA Novel New Approach to Treatment of Catastrophic Urinary Dysfunction
A Novel New Approach to Treatment of Catastrophic Urinary Dysfunction John B. Devine II, M.D., FACOG 1,2, Stanley E. Rittgers, PhD (Ret.) 1,3, Michael D. Serene, M.D. (Ret.) 1,4 1 3D Urologic, LLC, Akron,
More informationAntegrade ureteric stent insertion Patient information
Antegrade ureteric stent insertion Patient information This leaflet tells you about having antegrade ureteric stenting. It explains what is involved and what the possible risks are. It is not meant to
More informationZenith Alpha T HORACIC ENDOVASCULAR GRAFT
Deployment Sequence Zenith Alpha T HORACIC ENDOVASCULAR GRAFT www.cookmedical.com AI-D21183-EN-F Preparation and flush Proximal and distal components Remove the yellow hubbed inner stylet from the dilator
More information2013 Product Catalog
2013 Product Catalog LT 95033 D Table of Contents Men s Liberty.... 3 Men's Liberty Supporter 4 Additional Faceplate Seals.. 4 Safe n Dry..... 5 Cath Grip - Catheter Securement System... 6 UniGrip. 7 Grip
More informationWhat is the ICD 10 code for indwelling Foley catheter
What is the ICD 10 code for indwelling Foley catheter 2018 ICD-10 code for Encounter for fitting and adjustment of urinary device is Z46.6. indwelling catheter - Z46.6 stent. Sep 6, 2017. Can someone to
More informationHaving a Ureteric Stent What to expect and how to manage
Service: Urology Having a Ureteric Stent What to expect and how to manage Exceptional healthcare, personally delivered Introduction In patients who have, or might have, an obstruction (blockage) of the
More informationSecond-line Treatment for OAB
Patient Information English 35 Second-line Treatment for OAB The underlined terms are listed in the glossary. Sometimes the drugs your doctor prescribed do not improve your overactive symptoms (OAB). In
More informationEvidence Summary: The inflow Urinary Prosthesis FDA De Novo Approval DEN130044
Evidence Summary: The inflow Urinary Prosthesis FDA De Novo Approval DEN130044 Unique alternative to urinary catheters for women with permanent urinary retention Therapeutic benefits o Highly effective
More informationTHE THE MORE MORE NATURAL APPROACH TO OPTIMAL FIT
THE THE MORE MORE NATURAL APPROACH Natural Approach TO Optimal Fit TO OPTIMAL FIT Conformability without Compromise THE STANDARD IN Conformability AND Designed for flexibility and conformability in tortuous
More informationContinence Control System USER S MANUAL
Continence Control System USER S MANUAL Continence Control System User's Manual Caution: Read this user s manual completely before using this system Causes of Incontinence Causes are many and varied. Most
More informationLisette Ramos-Voigt November 25, Kidney Stone Formation. substances found in the urine (Leslie & Swierzewski, 1998). There are various types of
Lisette Ramos-Voigt November 25, 2008 Kidney Stone Formation Kidney stones are hard solid pieces of material that form in the kidneys out of substances found in the urine (Leslie & Swierzewski, 1998).
More informationKIDNEY STONES. When to call for help Call these rooms if any of the following occur:
KIDNEY STONES Background Kidney stones that move into the ureter (the narrow tube that drains each kidney) often cause a lot of pain. If the stones measure 5mm or less in diameter then most will eventually
More informationManaging your bladder with a Supra-pubic catheter at home
Managing your bladder with a Supra-pubic catheter at home Providing a range of NHS services in Gateshead, South Tyneside and Sunderland. Managing your bladder with a Supra-pubic catheter at home The purpose
More informationBIP Endotracheal Tube
Bactiguard Infection Protection BIP Endotracheal Tube For prevention of healthcare associated infections Ventilator associated pneumonia Infections of the respiratory tract are serious and common healthcare
More informationPatient information leaflet. Royal Surrey County Hospital. NHS Foundation Trust. Nephrostomy. Radiology
Patient information leaflet Royal Surrey County Hospital NHS Foundation Trust Nephrostomy Radiology This leaflet informs you about the procedure known as a nephrostomy. It explains what is involved and
More informationANTIBIOTIC USE DURING ENDOUROLOGIC SURGERY
ANTIBIOTIC USE DURING ENDOUROLOGIC SURGERY Comprehensive Kidney Stone Center at Duke University Medical Center Durham, North Carolina Glenn M. Preminger LEADING EDGE UROLOGY 49th Annual Duke Urologic Assembly
More information-vita THORACIC 3G. Stent Graft System SOLUTIONS FOR VASCULAR DISEASE
Stent Graft SOLUTIONS FOR VASCULAR DISEASE 1 PURE PERFORMANCE AND QUALITY: STENT GRAFT SYSTEMS BY JOTEC JOTEC is an innovation-oriented company with consistent focus on its core competencies: the development
More informationContinuous Bladder Irrigation
Continuous Bladder Irrigation Introduction Continuous bladder irrigation, or CBI, is the infusion of a sterile solution into the urinary bladder. The purpose of CBI is to prevent the formation of blood
More informationPROFESSIONAL RELIABLE
PROFESSIONAL RELIABLE SINGLE USE NEGATIVE PRESSURE WOUND THERAPY KIT REDUCE WOUND CARE TIME, BRAND NEW KIT WITH BIOCOMPATIBLE MATERIALS, MORE EFFECTIVE AND EASIER WOUND HEALING EXPERIENCE. REDUCE WOUND
More informationAntegrade ureteric stent
All of our publications are available in different languages, larger print, braille (English only), audio tape or another format of your choice. Tha gach sgrìobhainn againn rim faotainn ann an diofar chànanan,
More informationAcute Therapy Systems. provencare Catheter Sets
Acute Therapy Systems provencare Catheter Sets Catheter Sets Contents provencare Catheter Sets 4 provencare Product Features and Accessories 6 provencare Single Lumen Catheter Sets 8 provencare Paediatric
More informationNephrostomy. Radiology Department. Patient information leaflet
Nephrostomy Radiology Department Patient information leaflet This leaflet informs you about the procedure known as a nephrostomy. It explains what is involved and the possible risks. The benefits and risks
More informationAntegrade ureteric stent
Antegrade ureteric stent Information for you Follow us on Twitter @NHSaaa Find us on Facebook at www.facebook.com/nhsaaa Visit our website: www.nhsaaa.net All our publications are available in other formats
More informationDesigned to Reduce the Risk of Occlusion (1)
Designed to Reduce the Risk of Occlusion (1) more efficient flushing better outcomes The Vortex* ports feature the Vortex Technology for a more efficient flushing. The Vortex Technology sets up efficient
More informationOrtho Hygiene. #2078, Tuscany Blvd. NW, Calgary, AB T3L 2V7 Phone: Fax:
Ortho Hygiene You already know that maintaining good oral hygiene is important for everyone but when you re having orthodontic treatment, it s even more critical. Why? Because, while the appliances (such
More informationExperience the Innovative Therapy for Benign Prostate Enlargement
Experience the Innovative Therapy for Benign Prostate Enlargement A Guide to Treatment of Benign Prostatic Hyperplasia 1. 2. The Prostate The prostate gland is a part of the male reproductive system. A
More informationCystoscopy and insertion of a ureteric stent
Cystoscopy and insertion of a ureteric stent Urology Department Patient Information Leaflet Introduction This leaflet is for people who have been recommended to have a procedure called cystoscopy and insertion
More informationDJ STENT PROCEDURE. What does the procedure involve? What are the alternatives to this procedure?
What does the procedure involve? DJ STENT PROCEDURE Telescopic inspection of the bladder and urethra combined with insertion, removal or changing of a soft plastic tube placed between the kidney and the
More informationKey Definitions. Downloaded from
Key Definitions In order to make sure that every member of the team is clear about the definitions that will be used, we have provided a list of key terms in the next few pages along with commonly used
More informationRÜSCH CLOSED URINE DRAINAGE SYSTEMS. For maximum protection against nosocomial urinary tract infections
RÜSCH CLOSED URINE DRAINAGE SYSTEMS For maximum protection against nosocomial urinary tract infections 2 introduction TELEFLEX S RÜSCH CLOSED URINE DRAINAGE SYSTEMS SIMPLE, SAFE AND HYGIENIC Trusted brands
More informationAchieving Independence
Bard: Intermittent Self-Catheterization A Guide to Self-Catheterization Achieving Independence Introduction This brochure is provided by Bard, a leading provider of urology products since 1907. The best
More informationTypes of Intermittent Catheters and Access to Urological Supplies
Types of Intermittent Catheters and Access to Urological Supplies Anna Markiewicz; Sr Reimbursement Specialist Hollister Incorporated Lydia Cannady; Sr Product Manager Hollister Incorporated Why Catheterize?
More informationNEW INSTRUMENTS & DEVICES
NEW INSTRUMENTS & DEVICES Dalela Triple J Stent The commonly used Double J Stent causes a certain amount of dysuria and other storage LUTS because of trigonal irritation by lower coil of D J Stent. I have
More informationNegative Pressure Wound Therapy
ATMOS S 042 NPWT Negative Pressure Wound Therapy USER FRIENDLY SELF-EXPLANATORY RELIABLE Negative Pressure Wound Therapy A therapy with new approaches For many indications in the areas of chronic and traumatic
More informationTracheostomy/ Laryngectomy PRODUCT CATALOG
1 Tracheostomy/ Laryngectomy PRODUCT CATALOG 2 3 is a highly experienced manufacturer of medical devices for tracheostomized and laryngectomized patients. For many years we have been supplying our customers
More informationCATHETER-ASSOCIATED URINARY TRACT INFECTIONS
CATHETER-ASSOCIATED URINARY TRACT INFECTIONS Hamid Emadi M.D Associate professor of Infectious diseases Department Tehran university of medical science The most common nosocomial infection The urinary
More informationsleeve leg bag holder
independence with confidence optimum medical support Have you visited the patient support area of our website? It s been created to help you understand more about the procedures you experience, and the
More informationFor more than 2,500 years urinary catheters have been
Diamond-Like Carbon Coatings on Ureteral Stents A New Strategy for Decreasing the Formation of Crystalline Bacterial Biofilms? Norbert Laube,* Lisa Kleinen, Jörg Bradenahl and Andreas Meissner From the
More informationImaging of double J ureteral stents - what to look for?
Imaging of double J ureteral stents - what to look for? Poster No.: C-1181 Congress: ECR 2014 Type: Educational Exhibit Authors: V. Urban, M. Djosev, J. Ilic, G. Lukic, T. Nastasic, S. M. 1 2 1 1 3 1 3
More informationCatheter-Associated Urinary Tract Infection (CAUTI) Event
Device-associated Events Catheter-Associated Urinary Tract Infection () Event Introduction: The urinary tract is the most common site of healthcare-associated infection, accounting for more than 30% of
More informationGastric / EUS Metal Stents
Gastric / EUS Metal Stents In a fast paced and maturing market, Diagmed Healthcare s Hanarostent has managed to continue to innovate and add unique and clinically superior features to its already premium
More informationBARD LATEX FOLEY CATHETERS. Together, advancing the world of health. Utilization. Insertion. Maintenance. Duration
BARD LATEX FOLEY CATHETERS Utilization Insertion Maintenance Duration Together, advancing the world of health LATEX ALLERGIES ARE NOT NEW Approximately 1% of the U.S. population is estimated to be at risk
More informationPrevention of Important HAIs: Principle & Case Scenario in VAP/CAUTI. CPT. Pasri Maharom MD, MPH Dec 15, 2015
Prevention of Important HAIs: Principle & Case Scenario in VAP/CAUTI CPT. Pasri Maharom MD, MPH Dec 15, 2015 Catheter Associated Urinary Tract Infection CAUTI CAUTI Epidemiology Key Principles of Preventing
More informationNHS GREATER GLASGOW & CLYDE CONTROL OF INFECTION COMMITTEE STANDARD OPERATING PROCEDURE (SOP) INSERTION & MAINTENANCE OF INDWELLING
Page Page 1 of 6 AIM STATEMENT REQUIREMENTS LOCATION TIMING PROCEDURE To minimise the risk of secondary infection as a result of urinary catheterisation. A urinary catheter bypasses the body s normal defence
More informationProtecting Patients. Preserving Access.
MAHURKAR * Family of Acute Care Catheters Protecting Patients. Preserving Access. A full spectrum of acute care catheters for use in hemodialysis, apheresis, infusion and renal replacement therapy The
More informationIndwelling Urinary Catheters And Drainage systems
If you require this leaflet in any other format, e.g., large print, please telephone 01935 384256 Indwelling Urinary Catheters And Drainage systems Useful organisations Ms Society Helpline Tel: 0808 800
More informationZenith Alpha T HORACIC ENDOVASCULAR GRAFT
Device description Zenith Alpha T HORACIC ENDOVASCULAR GRAFT www.cookmedical.com AI-D21181-EN-F Modular design The two-piece modular system allows the physician to customize a graft system to fit each
More information90% of bladder tumours are transitional cell carcinoma (TCC), the remaining 10% of cases are squamous cell carcinoma, adenocarcinoma and sarcoma.
The Role of the Interventional Radiologist in Management of Post-Radical Cystectomy Ureteral Obstruction : A Case Review of Retrograde Transileal Conduit Ureteric Stents. Poster No.: C-2288 Congress: ECR
More informationEndoscopic Ultrasound Endoskopischer Ultraschall
Endoscopic Ultrasound Endoskopischer Ultraschall SonoTip Pro Control Endoscopic Ultrasound-Guided FNA System Single Use Twist-Lock Technology for Sheath & Needle Length Adjustments Offering Physician Controlled
More informationBioCath for your temporary vascular access
BioCath for your temporary vascular access MaxFlo and MaxFlo Slim Highflow Catheter Dual Lumen Catheter Single Lumen Catheter www.vascular-access.com BioCath MaxFlo and MaxFlo Slim MaxFlo Slim Catheter
More informationSurveillance will occur in all inpatient locations in Kuwait Ministry of Health hospitals.
Urinary Tract Infection (Catheter-Associated Urinary Tract Infection [CAUTI] Non-Catheter-Associated Urinary Tract Infection [UTI]) Other Urinary System Infection [USI]) Events Settings: Surveillance will
More informationCATHETERS: INSERTION, TIPS, AND TYPES - DALHOUSIE UNIVERSITY
PDF [PDF] COUDE CATHETER SIZES - 77PDFS.COM CATHETERS: INSERTION, TIPS, AND TYPES - DALHOUSIE UNIVERSITY 1 / 5 2 / 5 3 / 5 coude urinary catheter pdf catheter care guidelines. ANZUNS recommendations for
More informationQuick Reference Guide
Quick Reference Guide Indications for Use The AFX Endovascular AAA System is indicated for endovascular treatment in patients with AAA. The devices are indicated for patients with suitable aneurysm morphology
More informationIndwelling urinary catheter
Indwelling urinary catheter Information for patients and carers RDaSH leading the way with care What is a catheter? A catheter is a hollow flexible tube designed to drain urine from the bladder. Following
More informationRecanalisation of urethral strictures with new-generation temporary covered biocompatible metal endoprostheses
Acta Chirurgica Iugoslavica (ACI) Vol: LIV, (3) 2007, pages 123-127 SCIENTIFIC PAPER UDC: 616.65-007.271-089.819.5 Recanalisation of urethral strictures with new-generation temporary covered biocompatible
More informationHaving a ureteric stent inserted
Having a ureteric stent inserted This leaflet explains more about having a ureteric stent inserted. It describes the benefits, risks, alternatives and what you can expect when you come to hospital. If
More informationCombine the best of both worlds
S c i e n c e B a s e d E v o l u t i o n s l e a d t o R e v o l u t i o n a r y S o l u t i o n s PIONEER CoCr STENT ON DEB Combine the best of both worlds A next step in cardiovascular treatment should
More informationVersatility and Proven Safety
Versatility and Proven Safety Indicated for: Temporary or Permanent placement Standard or Over-The-Wire Delivery Jugular, Femoral, Antecubital, and Popliteal Access > Proven Safety Initial Clinical Trial
More information