CERAMIC-ON-METAL. References: Cat No: version 2

Size: px
Start display at page:

Download "CERAMIC-ON-METAL. References: Cat No: version 2"

Transcription

1 CERAMIC-ON-METAL References: 1. Beaule, P. E., et al. Jumbo femoral head for the treatment of recurrent dislocation following total hip replacement. J.Bone Joint Surg (2002). 84-A: Jolles, B. M., P. Zangger, and P. F. Leyvraz. Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis. J.Arthroplasty (2002) 17: Lachiewicz, P. F. and E. S. Soileau. Dislocation of Primary Total Hip Arthroplasty with 36 and 40 mm Femoral Heads. Clin Orthop Relat Res. (2006). 453: Padgett, D. E., et al. Influence of total hip design on dislocation: a computer model and clinical analysis. Clin.Orthop.Relat Res. 447 (2006) Firkins, P. J., et al. A novel low wearing differential hardness, ceramic-on-metal hip joint prosthesis1. J.Biomech. (2001) 34: Figueiredo-Pina, CG, Yan, Y, Neville, A, and Fisher, J. Analysis of Corrosive Wear in Metal on Metal and Ceramic on Metal Bearings for Hip Prostheses. Poster 1777, 53rd Annual Meeting of the Orthopaedic Research Society, San Diego, California, Nevelos et al. Biomaterials, 1999, 20, Wear of HIPed and Non-HIPed Alumina-Alumina Hip Joints Under Standard and Severe Simulator Testing Conditions. Biomaterials. Aug: 22(16):2191-7, Williams, S., et al. Ceramic-on-Metal Hip Replacements: Part 1 - In Vitro Testing. Engineers and Surgeons: Joined at the Hip. ImechE Conference, London, Schepers, A., MBBCh, et al. Ceramic-on-Metal Hip Replacements: Part 2 - Early Clinical Metal Ion Levels. Engineers and Surgeons: Joined at the Hip. ImechE Conference, London, Min, B. W., et al. Delayed Fracture of a Ceramic Insert With Modern Ceramic Total Hip Replacement. J.Arthroplasty 22.1 (2007): This publication is not intended for distribution in the USA S-ROM and Articul/eze are registered trademarks and Pinnacle, Ceramax, and Ultamet are trademarks of DePuy Orthopaedics, Inc. Biolox Delta is a registered trademark of Ceramtec AG DePuy International Limited. All rights reserved. Cat No: version 2 DePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0) Fax: +44 (0) Revised: 12/07

2 RECOVERY FUNCTION SURVIVORSHIP DePuy believes in an approach to total hip replacement that places equal importance on recovery, function and survivorship. 3

3 Combining the extremely low wear of ceramic with the toughness of metal, for active, demanding patients. 4 The ceramic-on-metal bearing combination brings a new option for the surgeon within the DePuy high performance bearing range. The use of differential hardness bearings has been common in many different industries, as a solution for optimised wear performance. DePuy has embraced this technology by extensively testing the combination of their Biolox Delta ceramic head and their Ultamet metal liner. 5

4 Smaller cup, bigger head. The inherent strength of Ultamet metal liners allow a smaller Pinnacle acetabular cup to be used in conjunction with a larger diameter Biolox Delta ceramic head. The potential to use a larger head means that ceramic-on-metal bearings can offer superior resistance to dislocation with increased range of motion, reduced wear, and enhanced bone preservation. 1,2,3,4 6

5 Mean wear rates for metal-on-metal, ceramic-on-metal and ceramic-on-ceramic bearing combinations 8 (The ceramic-on-metal combination used was Biolox Delta ceramic heads on Ultamet metal liners) The tribology of a unique low-wear combination. Biolox Delta heads and Ultamet metal liners. Metal Ion release levels for all bearing options 9 (The ceramic-on-metal combination used was Biolox Delta ceramic heads on Ultamet metal liners) The differential hardness bearing improves fluid film lubrication and reduces adhesive wear. 6,8,9 The ceramic-on-metal bearing minimises corrosive wear. 6,8,9 Improved wear performance results in reduced metal ions levels. 5,8,9 8 9

6 Overcoming stripe wear. Microseparation and rim loading can cause stripe wear in ceramic-on-ceramic bearings. 5,7 In-vitro tests have proven that differential hardness achieved through a ceramic-on-metal combination avoids stripe wear. 7,

7 Potential for liner fracture or chipping eliminated. Whilst modern ceramics are very tough there is still a potential for mechanical failure. Use of Ultamet liners and ceramic-on-metal bearings eliminates the potential damage to the ceramic liner. The chipping of the liner caused by prosthesis femoral neck impingement is eliminated by using ceramic-on-metal.10 Possible liner fracture due to extreme trauma is eliminated

8 Ordering Information DePuy High Performance Bearings Polyethylene XL Polyethylene 28 mm 9/10 Biolox Delta Head mm 9/10 Biolox Delta Head Neck Length mm 9/10 Biolox Delta Head Neck Length mm 12/14 Articul/eze Biolox Delta Head mm 12/14 Articul/eze Biolox Delta Head Neck Length mm 12/14 Articul/eze Biolox Delta Head Neck Length +5 Metal-on-metal mm 9/10 Biolox Delta Head Neck Length mm 12/14 Articul/eze Biolox Delta Head Neck Length +8.5 Ceramic-on-metal 28 mm 11/13 S-ROM Biolox Delta Head mm 12/14 Articul/eze Biolox Delta Head Neck Length +12 FUNCTION / INCREASED STABILITY PE 28 XLPE 36 XLPE COM 28 COM 36 LOW WEAR Ceramic-on-ceramic COC mm 11/13 S-ROM Biolox Delta Head Neck Length mm 11/13 S-ROM Biolox Delta Head Neck Length mm 11/13 S-ROM Biolox Delta Head Neck Length mm 12/14 Articul/eze Biolox Delta Head mm 12/14 Articul/eze Biolox Delta Head Neck Length mm 12/14 Articul/eze Biolox Delta Head Neck Length mm 12/14 Articul/eze Biolox Delta Head Neck Length mm 9/10 Biolox Delta Head mm 9/10 Biolox Delta Head Neck Length mm 9/10 Biolox Delta Head Neck Length mm 9/10 Biolox Delta Head Neck Length mm 11/13 S-ROM Biolox Delta Head mm 11/13 S-ROM Biolox Delta Head Neck Length mm 11/13 S-ROM Biolox Delta Head Neck Length mm 11/13 S-ROM Biolox Delta Head Neck Length mm 11/13 S-ROM Biolox Delta Head Neck Length mm Ultamet Alternative Bearing Insert mm Ultamet Alternative Bearing Insert OD 44 mm mm Ultamet Alternative Bearing Insert OD 46 mm mm Ultamet Alternative Bearing Insert OD 48 mm mm Ultamet Alternative Bearing Insert OD 50 mm mm Ultamet Alternative Bearing Insert OD 52 mm mm Ultamet Alternative Bearing Insert OD 54 mm mm Ultamet Alternative Bearing Insert OD 56 mm mm Ultamet Alternative Bearing Insert OD 58 mm mm Ultamet Alternative Bearing Insert OD 60 mm 36 mm Ultamet Alternative Bearing Insert mm Ultamet Alternative Bearing Insert OD 50 mm mm Ultamet Alternative Bearing Insert OD 52 mm mm Ultamet Alternative Bearing Insert OD 54 mm mm Ultamet Alternative Bearing Insert OD 56 mm mm Ultamet Alternative Bearing Insert OD 58 mm mm Ultamet Alternative Bearing Insert OD 60 mm mm Ultamet Alternative Bearing Insert OD 62 mm mm Ultamet Alternative Bearing Insert OD 64 mm mm Ultamet Alternative Bearing Insert OD 66 mm 14 15

Understanding Hip Implant Options

Understanding Hip Implant Options Understanding Hip Implant Options Cup (Socket) Bearing (Liner) Head Stem (Femur) Modern Hip Implants (Ball) Metal Femoral Head on Marathon Cross-linked Polyethylene Liner Proven materials Polyethylene

More information

Featuring. Technology. Product Rationale

Featuring. Technology. Product Rationale Featuring Technology Product Rationale 2 Optimum implant geometry Extending proven TRI-LOCK heritage The original TRI-LOCK Stem was introduced in 1981. This implant was the first proximally coated tapered-wedge

More information

Optimum implant geometry

Optimum implant geometry Design Rationale Optimum implant geometry Extending proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available

More information

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574) References 1. Sanchez-Sotelo J, Haidukewych GJ, Boberg CJ. Hospital Cost of Dislocation After Primary Total Hip Arthroplasty. J Bone Joint Surg. 2006;88A:290-294. 2. Brodner W, Grübl A, Jankovsky R, Meisinger

More information

Impingement in THA. Georgi I. Wassilew. Orthopaedic Department, Centrum für Muskuloskeletale Chirurgie Univ.-Prof. Dr. med. C.

Impingement in THA. Georgi I. Wassilew. Orthopaedic Department, Centrum für Muskuloskeletale Chirurgie Univ.-Prof. Dr. med. C. Georgi I. Wassilew Orthopaedic Department, Centrum für Muskuloskeletale Chirurgie Univ.-Prof. Dr. med. C. Perka Charité - Universitätsmedizin Berlin Orthoload club, Berlin Reasons for revision in THA Reason

More information

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique Enhanced Stability Constrained Liners Design Rationale Surgical Technique The Pinnacle Acetabular Cup System was designed to maximize the number of options available to the surgeon, and provide those options

More information

Product Rationale. Where Strength and Modularity Connect

Product Rationale. Where Strength and Modularity Connect Product Rationale Where Strength and Modularity Connect 2 ReClaim Modular Revision Hip System Advanced Strength 1 Advanced Strength Over 600 million cycles of testing 1 Advanced Fixation Advanced Instrumentation

More information

PINNACLE REVISION CUP SYSTEM

PINNACLE REVISION CUP SYSTEM PINNACLE REVISION CUP SYSTEM This publication is not intended for distribution in the USA. DESIGN RATIONALE FLEXIBILITY. PRECISION. CONFIDENCE. DePuy Synthes Joint Reconstruction is proud to offer the

More information

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis? Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis? Diagnosis: Ceramic head fracture In the 1970 s, Boutin implemented ceramic in modern total hip arthroplasty (THA).

More information

Optimum implant geometry

Optimum implant geometry Design Rationale Optimum implant geometry Extending the proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available

More information

Optimum implant geometry

Optimum implant geometry Surgical Technique Optimum implant geometry Extending proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available

More information

D E S I G N R A T I O N A L E

D E S I G N R A T I O N A L E D E S I G N R A T I O N A L E FREEDOM TO CHOOSE 1 PROVEN MODULAR SOLUTIONS The Pinnacle Acetabular Cup System is uniquely designed with a range of acetabular cup options, biological and mechanical fixation

More information

Enhancing stability and increasing range of motion. Metasul LDH Large Diameter Head

Enhancing stability and increasing range of motion. Metasul LDH Large Diameter Head Enhancing stability and increasing range of motion Metasul LDH Large Diameter Head The Metasul large diameter head technology is the result of in-depth research, development and clinical experience that

More information

Product Information. *smith&nephew POLARCUP Dual Mobility System

Product Information. *smith&nephew POLARCUP Dual Mobility System APPLYING SCIENCE TO MOBILITY Combined with VERILAST Technology for unmatched performance Product Information *smith&nephew POLARCUP Dual Mobility System APPLYING SCIENCE TO MOBILITY Combined with VERILAST

More information

CeramTec Medical Products. BIOLOX DUO Ceramic Bipolar System. Bone-sparing joint reconstruction with a maximum range of motion

CeramTec Medical Products. BIOLOX DUO Ceramic Bipolar System. Bone-sparing joint reconstruction with a maximum range of motion CeramTec Medical Products BIOLOX DUO Ceramic Bipolar System Bone-sparing joint reconstruction with a maximum range of motion 2 BIOLOX DUO Ceramic Bipolar System Less is more BIOLOX DUO is an alternative

More information

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5. Surgical Technique Contents Templating and Pre Operative Planning 2 Preparation of the Acetabulum 4 Trial Sizing and Impaction of the Shell 5 Cup Positioning 6 Joint Stability 7 Trial sizing and Impaction

More information

R3think your options. For US distribution only.

R3think your options. For US distribution only. R3think your options For US distribution only. R3think acetabular surgery It is widely accepted that total hip replacement surgery is one of the most successful procedures done today. Typically more thought

More information

The Leader in Orthopaedic Innovation

The Leader in Orthopaedic Innovation The Leader in Orthopaedic Innovation Wright is a leading international manufacturer and distributor of superior, easy to use, and innovative orthopaedic implants and instrumentation. For over 50 years,

More information

BIOTRIBOLOGICAL AND MECHANICAL ANALYSIS OF TOTAL HIP ARTHROPLASTIY FAILURE: How to break the code

BIOTRIBOLOGICAL AND MECHANICAL ANALYSIS OF TOTAL HIP ARTHROPLASTIY FAILURE: How to break the code BIOTRIBOLOGICAL AND MECHANICAL ANALYSIS OF TOTAL HIP ARTHROPLASTIY FAILURE: How to break the code Patrick Chaboche, MD patrick.chaboche@wanadoo.fr Former Head of Department of Orthopaedic Surgery. Centre

More information

PRODUCT RATIONALE & SURGICAL TECHNIQUE

PRODUCT RATIONALE & SURGICAL TECHNIQUE This publication is not intended for distribution in the USA. PRODUCT RATIONALE & SURGICAL TECHNIQUE THE PRODUCT OF LONG-TERM CLINICAL EXPERIENCE The TRILOC cemented UHMWPE cup is a direct descendant of

More information

FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY

FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY Fixation First FIXATION FIRST 1958 Charnley Hip Over 1,000,000 implanted 1 96.2 percent survivorship at 32 years

More information

Medical Products Division. BIOLOX DUO Ceramic Bipolar System. Bone-sparing joint reconstruction with a maximum range of motion

Medical Products Division. BIOLOX DUO Ceramic Bipolar System. Bone-sparing joint reconstruction with a maximum range of motion Medical Products Division BIOLOX DUO Ceramic Bipolar System Bone-sparing joint reconstruction with a maximum range of motion 2 BIOLOX DUO Keramisches Bipolarsystem BIOLOX DUO Ceramic Bipolar System Less

More information

All Ceramic Tripolar THA to Prevent Dislocations in Risky Patients

All Ceramic Tripolar THA to Prevent Dislocations in Risky Patients Chapter 6 All Ceramic Tripolar THA to Prevent Dislocations in Risky Patients Jean-Yves Lazennec, Adrien Brusson and Marc Antoine Rousseau Additional information is available at the end of the chapter http://dx.doi.org/10.5772/53251

More information

An Investigation into the Dynamic Loading of Ceramic-on-Ceramic Total Hip Replacements and its Relevance to Squeaking

An Investigation into the Dynamic Loading of Ceramic-on-Ceramic Total Hip Replacements and its Relevance to Squeaking An Investigation into the Dynamic Loading of Ceramic-on-Ceramic Total Hip Replacements and its Relevance to Squeaking Jim W. Pierrepont, MEng 1, Andrew J. Shimmin, MBBS, FRACS 2, Jonathan V. Baré, MBBS,

More information

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE CONTENTS Introduction 2 Pre-operative Planning 4 Determining the Centre of Rotation 5 Surgical Technique 6 Acetabular Preparation

More information

Move Ahead with Confidence. Hip Replacement Solutions from DePuy Orthopaedics

Move Ahead with Confidence. Hip Replacement Solutions from DePuy Orthopaedics Move Ahead with Confidence Hip Replacement Solutions from DePuy Orthopaedics The Healthy Hip Joint Pelvis Acetabulum (hip socket) Head of femur Neck of femur Femur (thigh bone) Head of femur in the acetabulum

More information

AUTOBLOQUANTE AUTOBLOQUANTE. Product Rationale Surgical Technique

AUTOBLOQUANTE AUTOBLOQUANTE. Product Rationale Surgical Technique AUTOBLOQUANTE AUTOBLOQUANTE Product Rationale Surgical Technique AUTOBLOQUANTE The Product of Long-Term Clinical Experience The AUTOBLOQUANTE femoral component is a direct descendant of the original straight

More information

PINNACLE Acetabular Cup System

PINNACLE Acetabular Cup System PINNACLE Acetabular Cup System Clinical Summary A Prospective, Randomized Study of Cross-Linked and Non-Cross-Linked Polyethylene for Total Hip Arthroplasty at 10-Year Follow-Up Engh CA Jr., Hopper RH

More information

CUTTING GUIDE SYSTEM PRODUCT RATIONALE. Custom-Made Patient Instruments for Total Knee Replacement

CUTTING GUIDE SYSTEM PRODUCT RATIONALE. Custom-Made Patient Instruments for Total Knee Replacement CUTTING GUIDE SYSTEM Custom-Made Patient Instruments for Total Knee Replacement This publication is not intended for distribution in the USA. PRODUCT RATIONALE 1 DePuy Synthes Joint Reconstruction TRUMATCH

More information

SELF-CENTERING Bipolar/Modular Cathcart Unipolar

SELF-CENTERING Bipolar/Modular Cathcart Unipolar SELF-CENTERING Bipolar/Modular Cathcart Unipolar Modular Endo Heads Surgical Technique Responding To The Surgeon The SELF-CENTERING Bipolar and Modular Cathcart Unipolar Endo Heads add versatility to the

More information

ARTICLE IN PRESS. Surface Oxidized Zirconium Total Hip Arthroplasty Head Damage Due to Closed Reduction. Effects on Polyethylene Wear

ARTICLE IN PRESS. Surface Oxidized Zirconium Total Hip Arthroplasty Head Damage Due to Closed Reduction. Effects on Polyethylene Wear The Journal of Arthroplasty Vol. 00 No. 0 2008 Surface Oxidized Zirconium Total Hip Arthroplasty Head Damage Due to Closed Reduction Effects on Polyethylene Wear William L. Jaffe, MD,* Eric J. Strauss,

More information

CORAIL Hip System. Clinical Summary

CORAIL Hip System. Clinical Summary CORAIL Hip System Clinical Summary 25-year ARTRO Results: A Special Vintage from the Old World Vidalain, J-P The CORAIL Hip System: A Pratical approach based on 25 years of experience. 2011; Chapter 4.2.1:94-101

More information

Ceramic Femoral Heads and Acetabular Cup Liners

Ceramic Femoral Heads and Acetabular Cup Liners Important Information: Please read prior to use in a clinical setting. The Surgeon should be familiar with the operative technique. Caution: Federal (U.S.A) law restricts this device to sale by or on the

More information

JOINT RECONSTRUCTION PORTFOLIO OVERVIEW

JOINT RECONSTRUCTION PORTFOLIO OVERVIEW JOINT RECONSTRUCTION PORTFOLIO OVERVIEW At DePuy Synthes Companies, we are inspired by you. DEPUY SYNTHES JOINT RECONSTRUCTION Uniquely focused on understanding today s opportunities and tomorrow s DePuy

More information

Amy Hendrickson Complaint/M DR Administrator DePuy Johnson & Johnson Phone: x 7179 Fax:

Amy Hendrickson Complaint/M DR Administrator DePuy Johnson & Johnson Phone: x 7179 Fax: From: To: CC: Sent: Subject: Hendrickson, Amy [DPYUS] Cary, Polly [DPYUS) Reimink, Matt [DPYUS] 12/ 19/2008 3:21:21 PM FW: ASR XL metal bearings demonstrated 99.2% survivorship at 3 years does NOT match

More information

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique ESC Enhanced Stability Liners Design Rationale & Surgical Technique Choice Without Compromise DePuy Synthes PINNACLE Hip Solutions are designed with a wide range of acetabular cup options, biological and

More information

Developing techniques for the dimensional assessment of true clinical wear in retrieved total joint replacements.

Developing techniques for the dimensional assessment of true clinical wear in retrieved total joint replacements. Developing techniques for the dimensional assessment of true clinical wear in retrieved total joint replacements. P. Bills*, L. Blunt*, G. Chakrabarty** *University of Huddersfield, Huddersfield, UK **West

More information

GENESIS II/ LEGION Total Knee System

GENESIS II/ LEGION Total Knee System GENESIS II/ LEGION Total Knee System The GENESIS II/LEGION knee with the VERILAST technology The knee tested to simulate 30 years of wear performance DISCLAIMER: Always speak to your doctor about the options

More information

INSTRUMENTS. Product Rationale

INSTRUMENTS. Product Rationale INSTRUMENTS Product Rationale R E C O V E R Y F U N C T I O N S U R V I V O R S H I P DePuy believes in an approach to knee arthroplasty that places equal importance on recovery, function and survivorship.

More information

Acetabular Cup System. Clinical Summary

Acetabular Cup System. Clinical Summary Acetabular Cup System Clinical Summary A Prospective, Randomized Study of Cross-Linked and Non-Cross-Linked Polyethylene for Total Hip Arthroplasty at 10-Year Follow-Up Engh CA Jr., Hopper RH Jr., Huynh

More information

G7 ACETABULAR SYSTEM. beautifully. efficient.

G7 ACETABULAR SYSTEM. beautifully. efficient. G7 ACETABULAR SYSTEM beautifully efficient. HERITAGE MEETS MODERN DESIGN SIMPLICITY, EFFICIENCY AND PERFORMANCE The G7 System is a multi-bearing acetabular platform delivering simplicity, efficiency and

More information

Stability without compromise. Epsilon Durasul Constrained Insert

Stability without compromise. Epsilon Durasul Constrained Insert Stability without compromise Epsilon Durasul Constrained Insert History of Dislocation and Constrained Acetabular Inserts The Need for a Better Solution The Problem Dislocation is the second most common

More information

The information contained in this document is intended for healthcare professionals only.

The information contained in this document is intended for healthcare professionals only. The information contained in this document is intended for healthcare professionals only. Trident Hemispherical Acetabular Shell Trident PSL HA Acetabular Shell Featuring: The Trident Acetabular System

More information

Zimmer TM. Continuum Acetabular System. Bringing together proven technologies.

Zimmer TM. Continuum Acetabular System. Bringing together proven technologies. Zimmer TM Continuum Acetabular System Bringing together proven technologies. The power to meet individual patient needs. Zimmer Continuum Acetabular System provides highly flexible solutions for orthopaedic

More information

SUMMIT and DURALOC. Clinical Summary

SUMMIT and DURALOC. Clinical Summary SUMMIT and DURALOC Clinical Summary Ten-year results of a press-fit, porous-coated acetabular component Grobler G.P. Learmonth I.D. Bernstein B.P. Dower B.J. (2005) The Journal of Bone and Joint Surgery;

More information

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter Design Philosophy Cementless Stems of 12/14 Taper Stem Length Neck shaft Angle STEM-N3 STEM-N4 STEM-N5 STEM-N6 STEM-N7 STEM-N8 STEM-N9 123 mm 125 mm 130 mm 135 mm 140 mm 145 mm 150 mm 132 Cement Polished

More information

Merete BioBall The Innovative Hip Endoprosthesis Head Adapter System

Merete BioBall The Innovative Hip Endoprosthesis Head Adapter System Merete the «BioBall Company» You are better off with BioBall Your Indispensable Assistant in Hip Arthroplasties. Merete BioBall The Innovative Hip Endoprosthesis Head Adapter System 2 BioBall System Merete

More information

This publication is not intended for distribution in the USA.

This publication is not intended for distribution in the USA. This publication is not intended for distribution in the USA. Extraction of a CORAIL Stem Surgical Technique Introduction Given the excellent long-term results of the CORAIL stem, 1,2,3 its extraction

More information

MetaFix Cementless Total Hip Replacement Product overview

MetaFix Cementless Total Hip Replacement Product overview MetaFix Cementless Total Hip Replacement Product overview MetaFix Evolution Versatility Simplicity Founded on 20 years experience in cementless technology with a proven, world-leading stem design, MetaFix

More information

Effect of Femoral Head Size to Contact Stress at Pure Titanium Femoral Ball Head Outer Surface of Hip Joint Implant

Effect of Femoral Head Size to Contact Stress at Pure Titanium Femoral Ball Head Outer Surface of Hip Joint Implant Effect of Femoral Head Size to Contact Stress at Pure Titanium Femoral Ball Head Outer Surface of Hip Joint Implant Agung Setyo Darmawan, Waluyo Adi Siswanto, Haryanti Samekto Faculty of Mechanical and

More information

THE ATTUNE REVISION FIXED BEARING KNEE SYSTEM

THE ATTUNE REVISION FIXED BEARING KNEE SYSTEM THE ATTUNE REVISION FIXED BEARING KNEE SYSTEM Instrumentation Designed to Enhance Efficiency and Versatility Surgical Process and Key Instrument Overview Introduction TABLE OF CONTENTS ADDRESS VARYING

More information

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE DePuy Synthes DURALOC Surgical Technique CONTENTS Templating and Pre Operative Planning 2 Preparation of the Acetabulum

More information

Scan Bi-Polar 22/28. Operative Technique

Scan Bi-Polar 22/28. Operative Technique Scan Bi-Polar 22/28 Operative Technique Disclaimer This publication and all content, artwork, photographs, names, logos and marks contained in it are protected by copyright, trademarks and other intellectual

More information

1.1 Ceramic on Ceramic Bearings Used with Proximal Modular Stems in THA K. J. Keggi, J. M. Keggi, R. E. Kennon and T. McTighe

1.1 Ceramic on Ceramic Bearings Used with Proximal Modular Stems in THA K. J. Keggi, J. M. Keggi, R. E. Kennon and T. McTighe 1.1 Ceramic on Ceramic Bearings Used with Proximal Modular Stems in THA K. J. Keggi, J. M. Keggi, R. E. Kennon and T. McTighe Abstract Introduction: Osteolysis generated by wear debris remains a problem

More information

*smith&nephew EP-FIT PLUS Cementless Press-Fit Cup System. Product Information

*smith&nephew EP-FIT PLUS Cementless Press-Fit Cup System. Product Information Product Information *smith&nephew EP-FIT PLUS Cementless Press-Fit Cup System EP-FIT PLUS Press-Fit Acetabular Cup System A new generation in press-fit cup technology Proven anchoring concept in combination

More information

Optimizing function Maximizing survivorship Accelerating recovery

Optimizing function Maximizing survivorship Accelerating recovery Surgical Technique Optimizing Function Maximizing Survivorship Accelerating Recovery The company believes in an approach to patient treatment that places equal importance on: Optimizing function Maximizing

More information

Bone Bangalore

Bone Bangalore Dr Suresh Annamalai MBBS, MRCS(Edn), FRCS( Tr & Orth)(Edn), FEBOT(European Board), Young Hip and Knee Fellowship(Harrogate, UK) Consultant Arthroplasty and Arthroscopic Surgeon Manipal Hospital, Whitefield,

More information

TaperFit. Cemented Total Hip Replacement Surgical technique

TaperFit. Cemented Total Hip Replacement Surgical technique TaperFit Cemented Total Hip Replacement Surgical technique TaperFit Contents Operative summary 4 Pre-operative templating 5 Surgical exposure 5 Femoral neck resection 5 Acetabular preparation 5 Cenator

More information

The information contained in this document is intended for healthcare professionals only.

The information contained in this document is intended for healthcare professionals only. The information contained in this document is intended for healthcare professionals only. Trident Poly Acetabular System Trident PSL HA Acetabular Shell with X3 Poly insert Trident Hemispherical Acetabular

More information

DePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0) Fax: +44 (0)

DePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0) Fax: +44 (0) This publication is not intended for distribution in the USA. DePuy Orthopaedics EMEA is a trading division of DePuy International Limited. Registered Office: St. Anthony s Road, Leeds LS11 8DT, England

More information

Prevention of dislocation after hip replacement in elderly patients. Piotr WOJCIECHOWSKI, Damian KUSZ, Mariusz NOWAK, Konrad KOPEĆ

Prevention of dislocation after hip replacement in elderly patients. Piotr WOJCIECHOWSKI, Damian KUSZ, Mariusz NOWAK, Konrad KOPEĆ Prevention of dislocation after hip replacement in elderly patients. Piotr WOJCIECHOWSKI, Damian KUSZ, Mariusz NOWAK, Konrad KOPEĆ Department of Orthopedics and Traumatology Medical University of Silesia

More information

Femoral Revision Algorithm. A practical guide for the use of the CORAIL Hip System in femoral revision surgery

Femoral Revision Algorithm. A practical guide for the use of the CORAIL Hip System in femoral revision surgery Femoral Revision Algorithm A practical guide for the use of the CORAIL Hip System in femoral revision surgery Introduction The principles that govern the mode of prosthetic fixation, implant stability

More information

Bone Preservation Stem

Bone Preservation Stem TRI-LOCK Bone Preservation Stem Featuring GRIPTION Coating Surgical Technique Implant Geometry Extending the TRI-LOCK Stem heritage The original TRI-LOCK Stem was introduced in 1981. This implant was

More information

RECLAIM REVISION HIP SYSTEM

RECLAIM REVISION HIP SYSTEM RECLAIM REVISION HIP SYSTEM Where Strength and Modularity Connect DESIGN RATIONALE System Overview RECLAIM Modular Revision Hip System WHERE STRENGTH & MODULARITY CONNECT 2 Offset Options Proximal Body

More information

Ceramic-on-metal bearings in total hip replacement

Ceramic-on-metal bearings in total hip replacement Ceramic-on-metal bearings in total hip replacement WHOLE BLOOD METAL ION LEVELS AND ANALYSIS OF RETRIEVED COMPONENTS G. H. Isaac, C. Brockett, A. Breckon, D. van der Jagt, S. Williams, C. Hardaker, J.

More information

Reaching new heights. Comprehensive. Efficient. Simple.

Reaching new heights. Comprehensive. Efficient. Simple. Reaching new heights Comprehensive. Efficient. Simple. Various acetabular cup choices Compatible with the different head and liner options including VERILAST Technology Reach for proven OR efficient Instrumentation

More information

Triple Tapered Stabilised Hip C-STEM AMT. Surgical Technique

Triple Tapered Stabilised Hip C-STEM AMT. Surgical Technique Triple Tapered Stabilised Hip C-STEM AMT Surgical Technique CONTENTS Pre-operative planning: X-ray templating 2 Step 1: Femoral Neck Resection 3 Step 2: Opening the Femoral Canal 4 Step 3: Metaphyseal

More information

Orthopaedics Business. Dave Illingworth, President February

Orthopaedics Business. Dave Illingworth, President February Orthopaedics Business Dave Illingworth, President February 23 2005 1 Smith & Nephew Orthopaedics Attractive market Strong performance Momentum 2 Attractive market Demographics - 2x Growth by 2020 Active

More information

S U R G I C A L T E C H N I Q U E

S U R G I C A L T E C H N I Q U E SURGICAL TECHNIQUE RECOVERY FUNCTION SURVIVORSHIP DePuy believes in an approach to total hip replacement that places equal importance on recovery, function and survivorship. The DePuy PROXIMA Hip System

More information

CAUTION: Ceramic liners are not approved for use in the United States.

CAUTION: Ceramic liners are not approved for use in the United States. Total Hip Prostheses, Self-Centering Hip Prostheses and Hemi-Hip Prostheses IMPORTANT: This essential product information sheet does not include all of the information necessary for selection and use of

More information

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS INTRODUCTION The Summit Tapered Hip System s comprehensive set of implants and instruments

More information

Approach Patients with Confidence

Approach Patients with Confidence Approach Patients with Confidence The is the first stem specifically designed to be utilized with tissue sparing approaches, such as the anterior approach, as well as traditional approaches. The implant

More information

LEGION Total Knee System. Exceptional Durability

LEGION Total Knee System. Exceptional Durability LEGION Total Knee System Exceptional Durability How many knee systems have been lab-tested to 30 years of simulated wear? Just one: LEGION Primary Knee System with VERILAST Technology The LEGION Primary

More information

THE ATTUNE REVISION ROTATING PLATFORM KNEE SYSTEM

THE ATTUNE REVISION ROTATING PLATFORM KNEE SYSTEM THE ATTUNE REVISION ROTATING PLATFORM KNEE SYSTEM Instrumentation Designed to Enhance Efficiency and Versatility Surgical Process and Key Instrument Overview Introduction TABLE OF CONTENTS ADDRESS VARYING

More information

Case Report Recurrent Catastrophic Ceramic Femoral Head Failure in Total Hip Arthroplasty

Case Report Recurrent Catastrophic Ceramic Femoral Head Failure in Total Hip Arthroplasty Case Reports in Orthopedics, Article ID 837954, 4 pages http://dx.doi.org/10.1155/2014/837954 Case Report Recurrent Catastrophic Ceramic Femoral Head Failure in Total Hip Arthroplasty S. M. M. Tai, 1 L.

More information

The arc of pelvic motion has been shown to be as great as 70 through sit to stand activities 1 DiGioia CORR 2006

The arc of pelvic motion has been shown to be as great as 70 through sit to stand activities 1 DiGioia CORR 2006 The arc of pelvic motion has been shown to be as great as 70 through sit to stand activities 1 DiGioia CORR 2006 Overview Every patient moves differently 1 and their total hip replacement should be optimised

More information

FLH /11

FLH /11 FLH 225 04/11 This publication has been issued by: European Central Marketing Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom Tel: +44 (0)1656 655221 Fax: +44 (0)1656 645454 www.biomet.com

More information

8.3 Tips and Tricks: Fracture of a Ceramic Insert

8.3 Tips and Tricks: Fracture of a Ceramic Insert Tips and Tricks 311 8.3 Tips and Tricks: Fracture of a Ceramic Insert with modern Ceramic Total Hip Replacement B.-W. Min, K.-S. Song, C.-H. Kang, K.-J. Lee, K.-C. Bae, C.-H. Cho and Y.-Y. Won Abstract

More information

System Surgical Protocol

System Surgical Protocol ADM X3 Mobile Bearing Hip System Surgical Protocol Available with X3 Advanced Bearing Technology For Use With Restoration ADM Cups and Inserts ADM X3 Mobile Bearing Hip System Surgical Protocol Warnings

More information

ReCap Product Rationale

ReCap Product Rationale ReCap Product Rationale A Complete resurfacing system designe engineering principles, tried and tested m clinically proven fixation methods Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales

More information

Exeter. Technical Guide

Exeter. Technical Guide Exeter Technical Guide Exeter Hip System Anatomic Restoration The Exeter hip system allows interoperative changes in offset, leg length and version, all independent of one another. This flexibility facilitates

More information

REFLECTION Constrained Liner Introduction

REFLECTION Constrained Liner Introduction Surgical Technique REFLECTION Constrained Liner Introduction Surgical treatment of recurrent dislocation should be directed toward correction of any mechanical abnormalities. If dislocation is caused

More information

DEPUY SYNTHES JOINT RECONSTRUCTION PATIENT EDUCATION SEMINAR

DEPUY SYNTHES JOINT RECONSTRUCTION PATIENT EDUCATION SEMINAR DEPUY SYNTHES JOINT RECONSTRUCTION PATIENT EDUCATION SEMINAR Welcome! Thank you for joining us! We hope today s information will help you on a path to reducing your pain and gaining mobility. This informational

More information

OXINIUM Femoral Heads. *smith&nephew

OXINIUM Femoral Heads. *smith&nephew Femoral Heads *smith&nephew Less wear More options Without the risks Even the best cobalt chrome and ceramic femoral heads come with the risks of wear or breakage. But with femoral heads, those risks are

More information

The Challenge of Durability in Hip Replacement

The Challenge of Durability in Hip Replacement The Challenge of Durability in Hip Replacement Gregory A. Tocks, D.O. Orthopedic Associates of Lancaster Ltd. INTRODUCTION Hip replacement is a very common operation, and the number of long-term postoperative

More information

Bi-Polar 22.2mm & 28mm System - Operative technique

Bi-Polar 22.2mm & 28mm System - Operative technique Disclaimer Biomet UK Ltd, as the manufacturer of this device, does not practice medicine and does not recommend any particular surgical technique for use on a specific patient. The surgeon who performs

More information

National Joint Replacement Registry. Lay Summary 2015 Annual Report Hip and Knee Replacement

National Joint Replacement Registry. Lay Summary 2015 Annual Report Hip and Knee Replacement National Joint Replacement Registry Lay Summary 2015 Annual Report Hip and Knee Replacement SUPPLEMENTARY REPORT 2015 TABLE OF CONTENTS Introduction... 1 A brief history of the Registry origins... 1 The

More information

Experimental Prediction of Contact Area in Hip Replacement and Hemi- Arthroplasty

Experimental Prediction of Contact Area in Hip Replacement and Hemi- Arthroplasty Experimental Prediction of Contact Area in Hip Replacement and Hemi- Arthroplasty Qianqian Wang, John Fisher, Sophie Williams. Institute of Medical and Biological Engineering, School of Mechanical Engineering,

More information

Cemented Cup. Surgical Technique

Cemented Cup. Surgical Technique Cemented Cup Surgical Technique Contents Introduction 2 Surgical Technique 5 Templating and Pre-Operative Planning 5 Approach to the Acetabulum 6 Reaming 6 Cup Positioning 8 Trial 9 Prepare Acetabulum

More information

Active Articulation E1

Active Articulation E1 Active Articulation E1 Dual Mobility Hip System Design Rationale Knees Hips Extremities Cement and Accessories PMI Trauma Technology Active Articulation E1 Dual Mobility Hip System Dual Mobility: Not a

More information

*smith&nephew POLARCUP Dual Mobility System. Product Information

*smith&nephew POLARCUP Dual Mobility System. Product Information Product Information *smith&nephew POLARCUP Dual Mobility System Dual Mobility 30 Years of Clinical Experience Concept combining an extended ROM, a low rate of dislocation and unexpectedly limited wear.

More information

Automated Industry Report 824 Depuy Synthes Australia Attune PS Total Knee

Automated Industry Report 824 Depuy Synthes Australia Attune PS Total Knee Automated Industry Report 824 Depuy Synthes Australia Total Knee Report Generated: 9 January 2019 This report has been prepared by the Australian Orthopaedic Association National Joint Replacement Registry

More information

CHARNLEY Wires. Surgical Techniques

CHARNLEY Wires. Surgical Techniques CHARNLEY Wires Surgical Techniques BACKGROUND CHARNLEY Trochanteric Wires are indicated for use in re-attachment of the greater trochanter following a trochanteric osteotomy. The use of a double wire

More information

We would like to thank the following surgeons for their participation as part of the R3 Acetabular System design team:

We would like to thank the following surgeons for their participation as part of the R3 Acetabular System design team: Design Rationale We would like to thank the following surgeons for their participation as part of the R3 Acetabular System design team: Robert Barrack, MD St. Louis, Missouri Robert Bourne, MD London Health

More information

Furlong H-A.C. THR System

Furlong H-A.C. THR System Important Information Please read prior to use in a clinical setting. The Surgeon should be familiar with the operative technique. Caution Federal (U.S.A) law restricts this device to sale by or on the

More information

What is the Best Bearing Type? 1/11/2011

What is the Best Bearing Type? 1/11/2011 What is the Best Bearing Type? 1/11/2011 A comparison of modern bearing types. Thomas P. Gross, M.D. As a patient there are four reasons you should consider a metal-on-metal bearing total hip replacement

More information

Disclosure. Direct Anterior THA via Extension Table. History 11/3/2015

Disclosure. Direct Anterior THA via Extension Table. History 11/3/2015 Direct Anterior THA via Extension Table J. Masonis, M.D. OrthoCarolina Hip & Knee Center Chief Adult Hip & Knee reconstruction Carolinas Medical Center Disclosure Consultant & Design Smith & Nephew Zimmer

More information

FLH183 04/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel. +44 (0) Fax: +44 (0)

FLH183 04/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel. +44 (0) Fax: +44 (0) FLH183 04/08 Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom Tel. +44 (0)1656 655221 Fax: +44 (0)1656 645454 Exceed ABT Operative Technique The Exceed ABT TM acetabular

More information