Abutment level impression Ⅰ. Combi abutment/dual abutment Multi units
|
|
- Jocelin Houston
- 5 years ago
- Views:
Transcription
1 Pr osthetic par t
2 Abutment level impression Ⅰ Combi abutment/dual abutment Multi units
3 Prosthetic part Remove Cover screw
4 Prosthetic part Remove Healing abutment
5 Prosthetic part Select suitable Combi abutment, then tighten it to 25~30N.cm [Re-tighten after 15 minutes]
6 Prosthetic part Connect Impression coping over the Abutment firmly [Snap-on mechanism]
7 Prosthetic part Take Impression [closed tray]
8 Prosthetic part Take Impression [closed tray]
9 Prosthetic part Fabricate provisional restoration, or use Comfort cap
10 Insert Lab analog into Impression coping [Match flat side of both analog & coping]
11 Fabricate soft tissue model
12 Fabricate master cast
13 PFM prosthesis: Seat Burn-out cylinder securely into Lab analog
14 Wax-up
15 Cut-back
16 Metal framework
17 Opaque
18 Porcelain build-up
19 Before delivery of final prosthesis
20 Delivery of final prosthesis
21 Zirconia prosthesis: Scanning of Lab analogs and adjacent teeth on master cast
22 Scanning of Lab analogs and adjacent teeth on master cast
23 Wax-up Cut-back
24 Zirconia framework
25 Porcelain build-up
26 Before delivery of final prosthesis
27 Delivery of final prosthesis
28 Abutment level impression Ⅱ Screw abutment PFM/PFG multi units
29 Screw abutment with delivery holder
30 Select and seat appropriate Screw abutment with delivery holder
31 After insertion, tighten it with Ratchet adapter [Tighten it to 25~30N.cm then Re-tighten after 15minutes]
32 Seat Impression coping on Screw abutment
33 Take impression (closed tray)
34 Seat comfort cap on the Screw abutment
35 Remove the impression coping from oral cavity and connect it with analog firmly
36 Insert the connected Impression coping and Analog into the impression
37 Fabricate soft tissue model
38 Fabricate master cast
39 Seat the Gold-cylinder on the Screw abutment Analog [Tighten it to 10N.cm with Ti-Retaining screw]
40 Consider the distance of opposing teeth, modify cylinder to its proper height if needed
41 Wax-up
42 Cut-back
43 Completed gold framework
44 Opaque
45 Porcelain build-up
46 Final prosthesis [Tighten it to 10N.cm with Ti-Retaining screw]
47 Delivery of final prosthesis
48 Fixture level impression Ⅰ Dual abutment/dual- milling abutment Transfer type
49 Remove Cover screw
50 Remove Healing abutment
51 Insert Impression coping (transfer type) into Fixture
52 Take Impression [closed tray]
53 Insert Lab analog into Impression coping [Match flat side of both analog & coping]
54 Fabricate soft tissue model
55 Fabricate master cast
56 Select abutment with proper diameter and gingival height
57 Fabricate positioning jig
58 Scanning of Lab analogs and adjacent teeth on master cast
59 Wax-up Cut-back
60 Zirconia framework
61 Porcelain build-up
62 Abutment tightening with positioning jig [Tighten it to 25~30N.cm and Re-tighten after 15 minutes]
63 Delivery of final prosthesis
64 Fixture level impression Ⅱ Dual abutment/dual- milling abutment Pick- up type
65 Remove Cover screw
66 Remove Healing abutment
67 Insert Impression coping (pick-up) into Fixture
68 Take impression [open tray]
69 Unscrew Impression coping screw before removing the impression tray
70 Fabricate soft tissue model
71 Fabricate master cast
72 Select abutment with proper diameter and gingival height
73 Fabricate positioning jig
74 Scanning of Lab analogs and adjacent teeth on master cast
75 Wax-up Cut-back
76 Zirconia framework
77 Porcelain build-up
78 Abutment tightening with positioning jig [Tighten it to 25~30N.cm and Re-tighten after 15 minutes] Delivery of final prosthesis
79 Fixture level impression Ⅲ Angled abutment Transfer type
80 Remove Healing abutment
81 Connect Impression coping
82 Connect Impression coping
83 Take impression [closed tray]
84 Fabricate master cast
85 Select proper Angled abutment
86 Fabricate positioning jig
87 Wax-up
88 Cut back
89 Completed Metal framework
90 Opaque
91 Porcelain build-up
92 Abutment tightening with positioning jig [Tighten it to 25~30N.cm and Re-tighten after 15 minutes]
93 Delivery of final prosthesis
SimpleLine II Surgical / Prosthesis Manual
SimpleLine II Surgical / Prosthesis Manual SimpleLine II SURGICAL MANUAL Surgical Drill Sequence 04 Fixture Installation 05 Fixture Connection 06 Surgical Kit Maintenance 08 Warnings 09 04 SimpleLine ll
More informationSuperLine & Implantium Surgical / Prosthesis Manual
SuperLine & Implantium Surgical / Prosthesis Manual SuperLine & Implantium SURGICAL MANUAL Surgical Drill Sequence I 04 Surgical Drill Sequence II 06 Drilling Depth Guide 08 Fixture Connection 10 Installation
More informationSuperLine & Implantium Surgical / Prosthesis Manual
SuperLine & Implantium Surgical / Prosthesis Manual SuperLine & Implantium SURGICAL MANUAL Surgical Drill Sequence 04 Drilling Depth Guide 06 Fixture Connection 08 Installation Procedure & Warnings 09
More informationTS Implant System 2013 PROSTHETIC PROCEDURE
TS Implant System 2013 PROSTHETIC PROCEDURE Contents TS Implant System Cement retained restoration Screw retained restoration 08 When abutment reduction is unnecessary 66 Screw retained restoration 21
More informationSS Implant System 2013 PROSTHETIC PROCEDURE
SS Implant System 2013 PROSTHETIC PROCEDURE Contents TS Implant System Cement retained restoration 06 Cement-retained bridges with the Solid abutment system (non-modified abutment) 16 Cement-retained bridges
More informationUS Implant System 2013 PROSTHETIC PROCEDURE
US Implant System 2013 PROSTHETIC PROCEDURE Contents TS Implant System Cement retained restoration 06 Cement retained bridges with the Cement abutment system 18 Cement retained crown with the Angled abutment
More informationLegacy Prosthetic Catalog
Legacy Prosthetic Catalog Straight Snap-On Straight Contoured Angled Contoured Ball Attachment Gold/Plastic Castable Locator Attachment Plastic Temporary Screw Receiving Plastic Non-Engaging Castable 15
More informationBlue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants
BIO Multi-Units are available for all our Bone Level Implants Multi-Units abutments are ideal for following restorative plans Blue Sky Bio offers a variety of components that can be used with BIO Multi-units.
More informationSolid Zirconia Full-Arch Implant Prosthesis (Protocol C All-CAD with Multi-Unit Abutments) BruxZir. FIRST Appointment. The BruxZir
(Protocol C All-CAD with Multi-Unit Abutments) Step-by-Step Restorative Protocol C The BruxZir Full-Arch Implant Prosthesis offers a fixed, all-zirconia implant solution for edentulous patients desiring
More informationsynocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions
synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions INTRODUCTION synocta Meso abutment for cement-retained restorations 1 The synocta Meso abutments, available
More informationPROSTHETIC PROCEDURE for TS & GS Implant System
Edition 03/2012 Prosthetic Procedure for TS & GS Implant System PROSTHETIC PROCEDURE for TS & GS Implant System OSSTEM Germany GmbH Mergenthalerallee 25 D-65760 Eschborn Tel: +49 (0) 61 96 / 777 55-0 www.osstem.com
More informationSlimLine CATALOG & MANUAL
www.implantium.com SlimLine CATALOG & MANUAL SLM-07(REV.2) Specifications are subject to change without notice. HQ (Korea) 4401 Trade tower 159, Samsung-dong, Kangnam-gu, Seoul, South Korea 135-729 T +82-2-501-8560
More informationElement-Z Screw-Retained Hybrid
Element-Z Screw-Retained Hybrid Implant-Level Restoration Step-by-Step Restorative Protocol The Element-Z Screw-Retained Hybrid offers a fixed, all-ceramic implant solution for edentulous patients desiring
More informationBIO-SERIES. compatible to: BioHorizons / internal. PLATFORM 3,0 mm 3,5 mm 4,5 mm 5,7 mm TITANIUM BASE SCAN BODY 3D-GUIDE NT-MILL LAB ANALOG
TITANIUM BASE for individual milled Zirconium Abutment incl. screw BIO 80300000 BIO 80350000 BIO 80450000 BIO 80570000 SCAN BODY 3D-GUIDE for intra + extra oral scanning BIO 9.S3D3.000 BIO 9.S3D3.500 BIO
More informationIMPRESSION PROCEDURES TRAINING MANUAL
IMPRESSION PROCEDURES TRAINING MANUAL 01 01 A.B. DENTAL A.B. Dental is proud to present this impression taking procedure protocol. This manual explains, step by step, the procedure while using A.B. Dental
More informationBEG-SERIES. compatible to: BEGO Implant Systems / Semados S, RS-RX, RI-Line 12 NT-TRADING CATALOGUE
TITANIUM BASE for individual milled Zirconium Abutment incl. screw BEG 80323700 BEG 80410000 BEG 80450000 BEG 80550000 SCAN BODY 3D-GUIDE for intra + extra oral scanning BEG 9.S3D3.237 BEG 9.S3D4.100 BEG
More informationStraight Octagon Abutment for Tissue Level Implant
Cover screw in place The presentation that follows lists only one combination of parts. Obviously the clinical situation may call for substitution of another part on this slide Prosthetic instruments needed
More informationfor individual milled Zirconium Abutment incl. screws Titanium Grade 5 ELI CAM CAM CAM CAM
TITANIUM BASE for individual milled Zirconium Abutment incl. screws CAM 80330000 CAM 80380000 CAM 80430000 CAM 80500000 SCAN BODY 3D-GUIDE for intra + extra oral scanning CAM 9.S3D3.300 CAM 9.S3D3.800
More information4766 Research Dr. San Antonio, TX insightdentalsystems.com
OVERVIEW OF THE INSIGHT DENTAL IMPLANT DELIVERY SYSTEM The IDS system comes in a unit dose implant system where its advantage provides sterile instrumentation in one single-use kit. It is organized to
More informationMiNi Overdenture Fixture
MiNi Overdenture Option MiNi Overdenture Fixture 1. Product Concept 1. Fast osseointegration for thanks to our SLA surface treatment. 2. Excellent for maxillary lateral incisor and mandible anterior. 3.
More informationSwissPlant Prosthetic Catalog. SwissPlant
SwissPlant Prosthetic Catalog Contoured Snap-On Angled Contoured Ball Attachment Gold/Plastic Castable Locator Attachment Plastic Temporary Screw Receiving Plastic Non-Engaging Castable Narrow Titanium
More informationTreatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l
Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l Two-Piece ReActive Tri-Lobe Implants with Multi-Unit Abutments One-Piece ScrewIndirect Implants
More informationINSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)
INSTRUCTIONS FOR THE DENTIST synocta impression procedure, Screw-retained and Snap-on Screw-retained (Open tray) Snap-on (Closed tray) click 1. Attach synocta Impression caps to implants. Hand-tighten
More informationPRODUCT CATALOG. Introduction. Prosthetic Procedure 1 Solid / Dual / SCA Abutment 13. Prosthetic Procedure 3 Screw Abutment 23.
PRODUCT CATALOG Introduction S.L.A. Surface 04 SimpleLine II Characteristics 05 SimpleLine II Color Coding by Diameter- G/H 1.6mm 08 SimpleLine II Fixture- G/H 1.6mm 09 SimpleLine II Color Coding by Diameter-
More informationNR Line Product Catalog 1. NR Line Product/Manual Catalog
NR Line Product Catalog 1 NR Line Product/Manual Catalog 2 NR Line Product Catalog NR Line Narrow Diameter Implant NR Line Product Catalog 3 Contents Introduction NR Line Characteristics 04 NR Line Fixture
More informationR-SERIES. compatible to: Zimmer Dental / Tapered Screw-Vent 36 NT-TRADING CATALOGUE PLATFORM 3,5 mm 4,5 mm 5,7 mm TITANIUM BASE
PLATFORM 3,5 mm 4,5 mm 5,7 mm TITANIUM BASE for individual milled Zirconium Abutment R 800 R 810 R 820 SCAN BODY 3D-GUIDE for intra + extra oral scanning R 9.S3D3.500 R 9.S3D4.500 R 9.S3D5.700 LAB ANALOG
More informationT-SERIES. compatible to: DENTSPLY Implants / Xive. PLATFORM 3,4 mm 3,8 mm 4,5 mm 5,5 mm TITANIUM BASE SCAN BODY 3D-GUIDE LAB ANALOG IMPLANT PICK-UP
PLATFORM 3,4 mm 3,8 mm 4,5 mm 5,5 mm TITANIUM BASE for individual milled Zirconium Abutment T 800 T 805 T 810 T 820 SCAN BODY 3D-GUIDE for intra + extra oral scanning T 9.S3D3.400 T 9.S3D3.800 T 9.S3D4.555
More informationUser Manual Complete Prosthetic Kit (CPK)
User Manual Complete Prosthetic Kit (CPK) The Complete Prosthetic Kit is designed to enable easy impression and transfer technique and to prevent the need to remove and to re-tighten the abutments. Advantages
More informationPart 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants
Select Part 2 Internal Tri-Channel Connection Replace Select NobelSpeedy Replace NobelReplace and compatible implants listed below Select Part 2 contains only the Tri-Channel Internal Connection compatible
More informationRestoring Straumann implants. with Locator abutments.
Restoring Straumann implants with Locator abutments. 1 1 Straumann is the industrial partner of the ITI (International Team for Implantology) in the areas of research, development, and education. Contents.
More informationcement-retained single crowns using cementable abutments
cement-retained single crowns using cementable abutments cement-retained restorations cement-retained single crowns using cementable abutments Cement-retained implant restorations are similar to conventional
More informationImplant Phase Flow Chart
Implant Phase Flow Chart 1. Surgical Phase Immediate Load 1. Place implant 1-2 mm below bone. 2. Attach crown posts at time of surgery using S17000 series abutments and (AS7001) Alan Key, and (AS7033)
More informationE-SERIES. compatible to: Nobel Biocare / Replace Select. PLATFORM 3,5 mm NP 4,3 mm RP 5,0 mm WP 6,0 mm TITANIUM BASE SCAN BODY 3D-GUIDE LAB ANALOG
PLATFORM 3,5 mm NP 4,3 mm RP 5,0 mm WP 6,0 mm TITANIUM BASE for individual milled Zirconium Abutment E 800 E 810 E 820 E 830 SCAN BODY 3D-GUIDE for intra + extra oral scanning E 9.S3D3.500 E 9.S3D4.300
More informationStep-by-Step Cemented Bridge Using Using CPK Abutments. Internal Hex. Implant System
4. 6. Step-by-Step Cemented Bridge Using Using CPK Abutments Internal Hex. Implant System MIS Corporation. All rights reserved. Published by MIS, which reserves the right to ameliorate the products described
More informationMulti-Unit Abutment Guide
Multi-Unit Abutment Guide SpiralTech TM Screw-Retained & Multi-Unit Restorations Our multi-unit abutment system is designed for restoration of both partially or fully edentulous arch cases Straight Multi
More informationUFII : Unique Fixture, 2 nd Generation. UFII Design Characteristics
UFII : Unique Fixture, 2 nd Generation UFII Design Characteristics 1. Hybrid SLA Surface Treatment 2. Tapered-Straight Combined Shape 3. Hex Internal Connection 4. Dual Morse Tapered Connection (11 Morse)
More informationNEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix
NEW The SmartFix Concept Prosthetic solution on tilted implants SmartFix The SmartFix Concept Prosthetic solution on tilted implants The SmartFix Concept is an effective and time-saving technique for immediate
More information/NobelReplace Ø4.3mm. /NobelReplace Ø3.5mm
Neoss Matrix Manual Neoss Matrix System Introduction The Neoss Matrix System has been designed to facilitate the fabrication of custom designed gold, titanium, other alloys and ceramic abutments or frameworks,
More informationReal World Implant Prosthetics: Fixed and Removable Samuel M. Strong, DDS
Real World Implant Prosthetics: Fixed and Removable Samuel M. Strong, DDS Presurgical planning Health history-systemic conditions Case presentation Financial agreement Radiographs- PA s, FMX, Panoramic,
More informationVery small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants
Very small abutment head easy and secure handling Ankylos The SmartFix concept Prosthetic solution on angled implants Stable prosthetic fit The area supporting the prosthesis is extended distally by the
More informationHex-Lock Abutment System. Restorative Manual
System Restorative Manual 32 Restorative options with s s are manufactured from titanium alloy and used as the support foundation for single- or multiple-unit cement-retained, partially edentulous fixed
More informationThe LOCATOR concept. Simplicity and versatility for prosthesis fixation
The concept Simplicity and versatility for prosthesis fixation The concept Experience the freedom in prosthesis fixation Simple and secure fixation of implant-supported prostheses is essential for successful
More informationOT EQUATOR CASTABLE Single Attachment for Overdentures
OT EQUATOR CASTABLE Single Attachment for Overdentures pick-up impression OT EQUATOR PROFILE CASTABLE MALE ATTACHMENT individual tray RETENTIVE CAPS OT EQUATOR HOUSING VIOLET CAP RIGID RETENTION (2.7Kg)
More informationS-SERIES. compatible to: DENTSPLY Implants / Astra Tech Implant System OsseoSpeed TX. PLATFORM 3,5 / 4,0 mm 4,5 / 5,0 mm TITANIUM BASE
TITANIUM BASE for individual milled Zirconium Abutment S 800 S 820 SCAN BODY 3D-GUIDE for intra + extra oral scanning S 9.S3D3.540 S 9.S3D4.550 LAB ANALOG S 50 S 52 IMPLANT PICK-UP for open-tray with integrated
More informationprosthetic technique manual
prosthetic technique manual table of contents table of contents introduction modules why choose BioHorizons prosthetics? surgical and prosthetic options & impression technique overview impression technique
More informationSlimLine Product Catalog & Manual 1. Unit:mm, Scale 1: 1.5 / mm. SlimLine. Product Catalog / Manual
SlimLine Product Catalog & Manual 1 Unit:mm, Scale 1: 1.5 / mm SlimLine Product Catalog / Manual 2 SlimLine Product Catalog & Manual Unit:mm, Scale 1: 1.5 / mm Contents Introduction S.L.A. Surface 04 SlimLine
More informationINSTRUCTIONS FOR USE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment
INSTRUCTIONS FOR USE STRAUMANN VARIOBASE ABUTMENT Straumann Variobase Abutment The ITI (International Team for Implantology) is the academic partner of Institut Straumann in the areas of research and education.
More informationWE VE MADE FIXED FULL-ARCH RESTORATIONS A SNAP. NO SCREWS. NO CEMENT. NO COMPROMISES.
WE VE MADE FIXED FULL-ARCH RESTORATIONS A SNAP. NO SCREWS. NO CEMENT. NO COMPROMISES. LOCATOR F-Tx A NEW WAY TO THINK ABOUT FIXED FULL-ARCH RESTORATIONS. LOCATOR F-Tx IS A SIMPLIFIED, TIME SAVING SOLUTION
More informationN-SERIES. compatible to: Straumann / SynOcta 32 NT-TRADING CATALOGUE PLATFORM 3,5 mm NN 4,8 mm RN 6,5 mm WN TITANIUM BASE SCAN BODY 3D-GUIDE
PLATFORM 3,5 mm NN 4,8 mm RN 6,5 mm WN TITANIUM BASE for individual milled Zirconium Abutment N 800 N 810 N 820 SCAN BODY 3D-GUIDE for intra + extra oral scanning N 9.S3D3.500 N 9.S3D4.800 N 9.S3D6.500
More informationImplant Restorations: A Step-By-Step Guide
Implant Restorations: A Step-By-Step Guide Drago, Carl DDS, MS ISBN-13: 9780813828831 Table of Contents Contributors. Foreword. Acknowledgments. Chapter 1. Introduction To Implant Dentistry. 1. Introduction.
More informationSmarter Thinking. Simpler Design. TiLobe Prosthetic Manual for PrimaConnex & Genesis implants
Smarter Thinking. Simpler Design. TiLobe Prosthetic Manual for PrimaConnex & Genesis implants Dear Customer, Thank you for allowing Keystone Dental Inc. the opportunity to provide solutions which we hope
More informationStraumann Dental System Indication-based prosthetic workflow. Technical Information
Straumann Dental System Indication-based prosthetic workflow Technical Information Contents Tissue Level Single Crown Screw-retained 2 Tissue Level Single Crown Cement-retained 4 Tissue Level Bridge Screw-retained
More informationA novel technique for fabrication of immediate provisional restorations
Clinical A novel technique for fabrication of immediate provisional restorations Pär-Olov Östman 1 Prosthetic rehabilitation of the edentulous patient with implant-supported restorations is a commonly
More information» For multi-unit restorations -
» For multi-unit restorations - conventional or digital «Multi-Unit Abutments 2 The Multi-unit product range is being contiunally expanded to include other abutment series. Available for a large number
More informationRePlant System Prosthetic Catalog
RePlant System Prosthetic Catalog Healing Collars, Transfers, Analogs & Alignment Tools Healing Collars Components include Dual-Grip feature for use with 1.25mmD Hex Tool or Nobel Unigrip ScrewDriver Width
More informationFIXED-HYBRID EMERGENCY! Why Redo When You Can Rescue?
FIXED-HYBRID EMERGENCY! Why Redo When You Can Rescue? FIXED-HYBRID FAILURES HAPPEN When a failing implant needs to be replaced in a fixed-hybrid case, it often leads to a prosthesis emergency. Replacing
More informationFor the oral rehabilitation
For the oral rehabilitation Contents For superstructures Chapter 1 Overview of prosthetic modes 1. Prosthetic modes of the PLATON system 2. Factors involved in prosthetic design Chapter 2 Cement-retained
More informationINDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag.
PROSTHESIS MANUAL INDEX PRESENTATION Pag. 05 CEMENT-SCREWED PROSTHESIS Pag. 12 INTRODUCTION PROSTHESIS MANUAL WARNINGS Pag. 06 Pag. 06 IMPRESSION TAKING: NECESSARY MATERIAL PROSTHESIS: NECESSARY MATERIAL
More informationMulti-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants
Multi-Unit Abutment System SIC Safe on Four Optimum use of available bone by angled placement of implants Multi-Unit Abutment System SIC Safe on Four Safe on Four The SIC Safe on Four system is a further
More informationWE VE MADE FIXED FULL-ARCH RESTORATIONS A SNAP.
LOCATOR F-Tx A NEW WAY TO THINK ABOUT FIXED FULL-ARCH RESTORATIONS. LOCATOR F-Tx IS A SIMPLIFIED, TIME SAVING SOLUTION for fixed full-arch restorations with no compromise to prosthesis strength or esthetics.
More informationStraumann synocta Prosthetic System Basic Information. Technical Information
Straumann synocta Prosthetic System Basic Information Technical Information About this guide The Basic Information on the Straumann synocta Prosthetic System provide dental practitioners and related specialists
More informationFull Arch Rehabilitation All-on-4 Technique Restorative Steps Recipe for Success
Full Arch Rehabilitation All-on-4 Technique Restorative Steps Recipe for Success Treatment Planning/Diagnosis 1. Setup meeting with Treatment Team to discuss case communication is key 2. Qualifying the
More informationLocator retained mandibular complete prosthesis (isy Implant System)
Locator retained mandibular complete prosthesis (isy Implant System) Mucosa-supported complete prostheses with poor fit greatly reduce people's quality of life. This is why the importance of implant-supported
More informationLegacy TM. System Catalog. Legacy TM 1 Legacy TM 2 Legacy TM 3 Legacy TM 4
Legacy TM System Catalog Legacy TM 1 Legacy TM 2 Legacy TM 3 Legacy TM 4 Table of Contents Page # Design, Surface & Dimensions 1-5 6-13 Legacy TM 1, Legacy TM 2, Legacy TM 3 & Legacy TM 4 s Labeling &
More informationNR Line Product/Manual Catalog
1 NR Line Product Catalog NR Line Product Catalog 2 NR Line Product Catalog NRPMC-1804 [Rev.0] NR Line Product/Manual Catalog NR Line Product/Manual Catalog Specifications are subject to change without
More informationSwishPlant. SwishPlant System Catalog. 4.8mmD mmD. 4.8mmD mmD. 3.7mmD mmD. 6.5mmD
SwishPlant System Catalog ------------ 4.1mmD ------------ 3.7mmD ------------ 3.3mmD SwishPlant 6.5mmD ------------ 6.5mmD ------------ 5.7mmD Table of Contents SwishPlant Fixture Mount Packaging Page
More informationQuick start Prosthetics
EN Quick start Prosthetics Easy and effective YELLOW PROSTHETIC PLATFORM QN CEMENTED RESTORATIONS ESTHETIC AUTMENTS OPEN TRAY POST IMPLANT ANALOG Indexed components with internal conical connection. 0.7
More informationContinuing Education. Implant Prosthetics for the General Practice. Samuel M. Strong, DDS
Implant Prosthetics for the General Practice Samuel M. Strong, DDS We are pleased to offer you free CE in your Dentaltown Magazine! You can now read a CE article in the magazine and go online to www. to
More informationinternal Impression Technique Guide Internal Implant System
internal Impression Technique Guide Internal Implant System Science Simplicity Value Impression Technique - Indirect Transfer with the 3inOne Abutment / Ball-top Screw Combo Procedure Objective: Make an
More informationMulti-unit abutment open tray technique using the direct pick-up coping
Multi-unit abutment open tray technique using the direct pick-up coping impression techniques Multi-unit abutment open tray technique using the direct pick-up coping Use this technique to make an impression
More informationEven faster thanks to ExpertEase Immediate restoration directly following implant placement. new
Even faster thanks to ExpertEase Immediate restoration directly following implant placement new The Initial Situation: Patients want beautiful teeth quickly preferably directly after the implantation Patients
More informationNR Line Product Catalog
NR Line Product Catalog NR Line Contents Introduction S.L.A. Surface 04 NR Line Characteristics 06 NR Line Color Coding by Diameter 08 NR Line Fixture 09 Surgical Components Cover Screw 10 Healing Abutment
More informationCROWN AND BRIDGE RESTORATIONS WITH THE SYNOCTA PROSTHETIC SYSTEM
CROWN AND BRIDGE RESTORATIONS WITH THE SYNOCTA PROSTHETIC SYSTEM Straumann is the industrial partner of the ITI (International Team for Implantology) in the areas of research, development, and education.
More informationAstra Tech Implant System. Clinical & laboratory manual. Screw-retained restorations. Astra Tech Implant System EV
Astra Tech Implant System Clinical & laboratory manual Screw-retained restorations Astra Tech Implant System EV The Astra Tech Implant System EV is designed for ease of use and versatility in providing
More informationInterActive TM System. Catalog
InterActive TM System Catalog Table of Contents Page # Implant Design 1 2-3 2 Implant Dimensions Impression Technique 3 4-5 Implant Details Selection Charts: Implants, Abutments, Components 10-11 6-7 8
More informationStraumann Screw-retained Prosthetics
Straumann Screw-retained Prosthetics Straumann Screw-retained Abutments Straumann Screw-retained abutments Indication and product features Abutments for fixed screw-retained restorations; for multi-unit
More informationinternal impression quick reference guide
internal impression quick reference guide IMPRESSION TECHNIQUE OVERVIEW Procedure Objective: This guide provides you with 3 of the most common impression techniques using the BioHorizons Tapered Internal
More informationAnkylos. Product Catalog
Product Catalog General prosthetic advice for In order to obtain utmost benefit from the unique restorative features of the implant system, please observe the following guidelines: Avoid occlusal overload,
More informationMulti-unit abutment closed tray technique using the indirect transfer coping
Multi-unit abutment closed tray technique using the indirect transfer coping impression techniques Multi-unit abutment closed tray technique using the indirect transfer coping Use this technique to make
More informationA Clinician s Guide to Restoring Conus
1994 A Clinician s Guide to Restoring Conus CONUS CONCEPT PROVIDED BY Dear Doctor, Absolute Dental has specialized in fixed prosthetics with an emphasis on Implant dentistry for more than two decades.
More informationPART 6. Implant Prosthodontics
PART 6 Implant Prosthodontics 26/11/2015 LIMU Dr. Rafik M. Alkowafi 188 In many respects the prosthodontic treatment for a single tooth is straightforward if the planning and placement of the implant is
More informationESTHETIC LINE implant
EL ESTHETIC LINE implant EL ESTHETIC LINE implant TABLE OF CONTENTS EL - ESTHETIC LINE implant Implant characteristics page 04 Dental implants page 05 Closed tray impression transfer page 06 Open tray
More informationInterActive System CONICAL. Prosthetic Catalog. simplycrown & bridge SMART PACK. InterActive All-in-1 Packaging simplyinteractive Mount-Free
InterActive System Prosthetic Catalog simplycrown & bridge SMART PACK InterActive All-in-1 Packaging simplyinteractive Mount-Free CONICAL Cover Screws, Healing Collars & Transfers Replacement Surgical
More informationImplant And Abutment Level Impressions
Implant And Abutment Level Impressions Implant And Abutment Level Impressions Pick-Up Impression Copings Certain Internal Connection is illustrated below. 1. Select the proper Pick-Up Impression Coping
More informationUniversal Plunger Loc Attachment
Universal Plunger Loc Attachment www.preat.com 800-232-7732 Universal Plunger Loc Complete Universal 7.5mm length TI plunger attachment. Compatible with Lew Passive and Swiss Loc NG. 1.5mm plunger, 7.5mm
More informationTRI-TAPERED Implant System
Implant System PRODUCT N 1 CATALOG 2018 Table of contents mplants... 3 Prosthetics Lab Components, Abutments... 4 Zest LOCATOR, R-Tx and F-Tx...5 Multi-Unit Abutments...6 Instruments...7 DRS International
More informationINTRODUCTION. Why Choose Cortex Prosthetics?
Prosthetic Manual 4 INDEX Introduction 6-14 Impression Techniques 15-29 Abutments Selection Handling 30-33 Temporary Restorations 34-38 Screw Reiained Restorations 39-52 Removable Restorations 53-63 5
More informationNARROW DIAMETER implant
ND NARROW DIAMETER implant TABLE OF CONTENTS ND - NARROW DIAMETER implant Implant characteristics page 04 Dental implant page 05 Open Tray Impression Transfer page 06 Titanium Abutments page 07 O-Ball
More informationIMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit
a perfect fit IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS Open and closed impression-taking Impression-taking for option platform switching Bite registration Temporary
More informationProsthetic Guideline. Dental Implant System Tissue Level
Prosthetic Guideline Dental Implant System Tissue Level TL Contents Dental Implant System Implant Characteristics 7 Prosthetic Systems 41 Implant Series 8 Solid Abutment System 43 This guideline was developed
More informationInterActive System Catalog
InterActive System Catalog Table of Contents Page # Implant Design & Surface 1 2-3 2 Implant Dimensions Fixture Mount & IQity Impression Technique 3 4-5 InterActive Implants Selection Chart 10-11 6-7 8
More informationPROSTHETIC OPTIONS FOR NARROW NECK IMPLANTS
PROSTHETIC OPTIONS FOR NARROW NECK IMPLANTS CONTENTS 1. Introduction 2 2. System overview 3 3. Product overview 4 4. Restorative procedures for the Narrow Neck implant 6 Fabrication of a provisional 6
More informationExtraction with Immediate Implant Placement and Ridge Preservation in the Posterior
Extraction with Immediate Implant Placement and Ridge Preservation in the Posterior by Timothy F. Kosinski, DDS, MAGD The following case presentation illustrates the diagnosis, planning and treatment for
More informationSimple Solutions Prosthetic Technique Manual
Simple Solutions Prosthetic Technique Manual simple solutions Simple Solutions Technique Guide Overview Introduction Abutment Selection Restorative Kits Individual Simple Solutions Components 1 2-3 4 5
More informationBasic information on the. Straumann Pro Arch TL. Straumann Pro Arch TL
Basic information on the Straumann Pro Arch TL Straumann Pro Arch TL Contents 1. Introduction 2 1.1 Discover more treatment options with the 4 mm Short Implant 2 2. Technical information 3 3. Step-by-step
More informationTrabecular Metal and Tapered Screw-Vent Implant Systems. Restorative Manual
Trabecular Metal and Tapered Screw-Vent Implant Systems Restorative Manual Table of Contents Overview 3 General Information 3 Platform Plus Connection 3 Restorative Options 4 Partially Edentulous 4 Fully
More informationThe solution for the edentulous patients. Prosthetics compatibillity 3i Multi-unit Abutment Regular Abutment (MegaGen)
The solution for the edentulous patients Various s Straight Type : 2, 3, 4, 5mm Angled Type : 1, 2, 3, 4mm Prosthetics compatibillity 3i Regular Abutment (MegaGen) Various Angles Straight, 17, 29 Design
More informationß For cement-retained crowns and bridges. Note: synocta cementable abutments. ß Can be especially helpful with large multi-unit cases Note:
Choosing the correct Straumann abutment for crowns, bridges, and bars Straumann abutments are torqued to 35 Ncm by using the ratchet with torque control device and the appropriate abutment driver. Abutments
More informationAll Ceramic KZR Solid (Full Contour Posterior Zirconia Crown) $79 KZR Anterior (Full Contour Anterior Zirconia Crown) $99 KZR Layered (Porcelain Layer
Full Service Fee Schedule CAD/CAM Flexible Partials Implants IPS e.max Prosthetics Orthodontics PFM Nightguards All Ceramic KZR Solid (Full Contour Posterior Zirconia Crown) $79 KZR Anterior (Full Contour
More informationHEXAGON Implant System
HEXAGON Implant System PRODUCT N 1 CATALOG 2018 2 Table of contents Implants... 4 Prosthetics Lab Components, Abutments... 5 Zest LOCATOR, R-Tx and F-Tx...6 Multi-Unit Abutments...7 Instruments...8 Zest