MATERIAL SAFETY DATA SHEET (MSDS) Information about stainless steel for Surgical/Dental/Orthodontic Instruments.
|
|
- Noreen Lawrence
- 5 years ago
- Views:
Transcription
1 MATERIAL SAFETY DATA SHEET (MSDS) THE INFORMATION BELOW IS BELIEVED TO BE ACCURATE AND REPRESENTS THE BEST INFORMATION CURRENTYLY AVAILABLE TO US. HOWEVER, WE MAKE NO WARRANTY OF MERCHANTABILITY OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, WITH RESPECT TO SUCH INFORMATION, AND WE ASSUME NO LIABILITY RESULTING FROM ITS USE. USERS SHOULD MAKE THEIR OWN INVESTIGATIONS TO DETERMINE THE SUITABILITY OF THE INFORMATION FOR THEIR PARTICULAR PURPOSES. Information about stainless steel for Surgical/Dental/Orthodontic Instruments. 1. Preparation for disinfection and cleaning Instruments should be disinfected and cleaned immediately after use. Any soiling left to dry will make eventual cleaning much more difficult and could result in damage to the instruments. The instruments should be taken apart, if necessary, allowing the disinfectant to cover all surfaces. For disinfection of the instruments either humid heat or chemical disinfection can be used. Humid heat is preferable providing the instruments are suitable for treatment in this manner. Under no circumstances must instruments be soared in physiological saline solution as prolonged contact causes pitting and rust, and Passivation of Instruments with Tungsten Carbide inserts is prohibited. (where nitric acid and sodium dichromate solution is used which will have drastic effect on the T/C instruments) Undue dropping can cause damage to the Instruments. Hard metal tips on Scissors/Cutters may be chipped or small delicate Clamps can be deformed. In order to avoid this, carefully handle and deposit the Instruments after use. To avoid encrustation and corrosion, in case of removal in dry condition and return to the CSSD (Central Sterilization Service Department), the Instruments must immediately be subject to machine treatment. For this treatment, deposit the Instruments on suitable trays, e.g. perforated sterilizing trays. For effective cleaning, hinged Instruments have to be
2 opened (such as Scissors, Clamps, Gouge Forceps). Instruments that are subject to machine treatment have to be immersed into a combined disinfecting and cleaning agent. For removal in wet condition and return to CSSD(Central Sterilization Service Department) use only non-corrosive agents in prescribed concentrations. Water alone is not sufficient. The Instruments have to be fully covered by the solution. Instruments should never be left overnight before cleaning as the risk of causing permanent damage increases with the length of time between use and preparation. 2. Manual disinfecting and cleaning. For manual preparation, Instruments have to be immersed into a combined disinfecting and cleaning solution with proven disinfecting effect. The instructions of the manufacturer have to be strictly followed regarding concentration, temperature and induction time. Use fresh disinfecting and cleaning solutions every day. The following problems may occur due to using the same solution for too long. Risk of corrosion due to soiling Risk of corrosion due to increasing concentration caused by evaporation. Decrease of disinfecting effect due to excessive dirt concentration. Instruments with a narrow lumen (tubing, cannulae) or with cavities are generally difficult to prepare. One must, therefore take care that the passages are free and that the inside is completely in contact with the solution. After chemical disinfection and cleaning, the Instruments must always be rinsed well under running water. Any residue has to be removed manually (no metal brushes, no scouring agents) In order to avoid water spots, a final rinsing with demineralized water is recommended. Finally, the Instruments have to be dried immediately 3. Machine Disinfection and cleaning. Machine preparation is usually done in the case of a dry return to CSSD. When wet removal to CSSD(Central Sterilization Service Department) is the case, then either a low-foam
3 producing disinfectant has to be used or else the Instruments have to be thoroughly prewashed as foam development in the machine can considerably influence the cleaning results. The temperature of the inflowing water should not exceed 45 C as higher temperatures lead to protein coagulation and cause cleaning problems. Disinfection can either be performed chemo-thermally or thermally. Attention has to be paid to the following:- Hinged Instruments have to be opened, thus guaranteeing through cleaning in the joint Do not overload the perforated trays so that all Instruments can be well rinsed A thorough internal flow has to be guaranteed with Instruments having long, narrow cavities (tubing, cannulae, breathing systems). Use special inserts. Remnants from the cleaning phase have to be totally removed in the subsequent rinsing procedures as otherwise spotting and/or discoloration may occur. Additional use of a suitable neutralizing agent improves the rinsing results. For final rinsing, a temperature of C has proved to be best. Sterile and demineralized water should be used. 4. Ultrasonic treatment. Ultrasonic treatment is particularly suitable for cleaning Instruments of high-grade steel. Attention should be paid to the following points: Fill the bath up to the makings. Add a suitable cleaning and/or disinfecting agent to the water. Temperature above 40 C promotes degreasing and cleaning. When using disinfecting and cleaning agents make sure that the concentration and temperature are correctly maintained. Instruments have to be completely covered by the cleaning solution. Hinged Instruments e.g. Scissors and Clamps etc have to be opened. After ultrasonic treatment, the Instruments have to be thoroughly rinsed either manually or by machine. Rinsing has to be performed with clear water of at least drinking quality or better still, with demineralized water in order to avoid water spots.
4 The Instruments should then be thoroughly dried. 5. Care and maintenance. Instruments with joints or ratchets have to be treated with suitable lubricating agent during the cleaning process. 6. Inspection. After each cleaning the Instruments have to be macroscopically cleaned, i.e. visible protein remnants and other contamination. Worn out or damaged Instruments should be removed for repair or replacement. Corroded Instruments should be discarded immediately as these can cause contact corrosion even on a perfect Surgical Instruments. Stains on Surgical Instruments are due to improper preparation. Causes of such stains or spots can be: Insufficient mechanical or manual cleaning Unsuitable cleaning, disinfecting and care agents. Failure to observe the dosage instructions for cleaning, disinfecting or care agents. Remnants of cleaning and disinfecting agents insufficient rinsing Poor water quality. Residues in the sterilizing steam when steam quality is not in accordance with recommendations. Remnants of medications, marking pens or chemo-indicators. Procedural faults e.g. not cleaning brand-new Instruments prior to sterilization. 7. Sterilization. The following proposals have to be observed. Sterilization conditions as well as units have to be in conformity with valid quality standards. Follow the sterilization instructions of the manufacturer. Autoclaving.
5 Temperature 134 C Hinged Instruments like Scissors, Clamps to be opened. The loading weight of perforated trays filled with Instruments should not exceed 10 Kgs. Temperature 180 C Not suitable for rigid and flexible endoscopes. Care & Handling of Instruments Some basic points for the care and handling of dental and surgical instruments, that will extend the life of instruments, eliminate staining or corrosion. 1. Instruments should be rinsed as soon as possible after use to remove blood, serum and saline. Do not use sponge basin as any residue from normal saline solution can cause corrosion to develop over a period of time. 2. Instruments should be thoroughly dried after cleaning and before rewrapping or sorting, as moisture left in the box lock or serrations can cause rust or corrosion to develop. 3. Do not leave instruments in a cold sterilization soak solution for extended periods as these solutions tend to be corrosive, after cold sterilization, rinse the instruments in distilled or demineralized water and dry thoroughly. 4. If using cold sterilization technique, change the solution according to directions as prolonged use will cause the solution to become corrosive. 5. Do not use caustic cleaners or any other cleaner except those specified for cleaning surgical instruments. 6. Do not clean instruments with steel wool or scouring powder, or use him PH detergents. If cleaning by hand, use specific instruments cleaner or a natural detergent soap and a soft brush (rinse with demineralized or distilled water). 7. Check your autoclave. Iron, sodium, calcium, magnesium or copper in your water can cause spotting, staining or corrosion to occur. In hard water areas, clean the line deposits from your autoclave, install a steam filter if possible. It will remove most of dirt, rust and pipe scale. 8. Make sure the wraps are rinsed sufficiently (6-8 times) to remove all chlorine bleach as any residue can cause staining or corrosion during autoclaving.
6 9. Do not leave instruments in the following solution for extended periods as corrosion can result - a) Aluminum, Barium, Calcium, Ferrous or stannous chloride solutions. b) Phenol, Lysol or Lodine. c) Dakin s Solution or Zephirin. d) Any acid, Mercury or potassium solution. 10. Do not sterilize stainless steel instruments with chrome plated instruments if possible, as any break in surface of the chrome plate will allow and electrolytic action develop between the dissimilar metals, causing pitting and/or a rusty appearance to develop. 11. Preheat instruments in autoclave before allowing steam to enter, if possible, to prevent an excessive amount of condensation forming on the surface of the instruments. 12. Don t open the autoclave too quickly after the sterilization cycles as excessive condensation will develop on the surface of the instruments (crack the clave to allow drying before opening fully). By above steps and using instruments cleaners and lubricant, your instruments should remain rust, spot and stain free. We hope it has answered any questions you might have on care of the stainless steel instruments. COMPOSITION OF STAINLESS STEEL USED: Composition Table (%) C : 20 Si : 51 Mn : 44 P : 17 S : 4 Ni : 7 Cr : 13.10
Scope This policy applies to all personnel and departments that clean, prepare and/or sterilize items intended for patient care use.
Dental Sterilization Procedures Policy Number VIM4(4)-10 Purpose The purpose of this policy is to ensure patient and employee safety when using instruments with potential for exposure to bloodborne pathogens
More informationM6-C Artificial Cervical Disc Surgical Instruments
CARE AND HANDLING INSTRUCTIONS Orthofix Inc. 3451 Plano Parkway Lewisville, Texas 75056-9453 U.S.A. 1-214-937-3199 1-888-298-5700 www.orthofix.com OSI-CustomerService@Orthofix.com Spinal Kinetics LLC,
More informationINSTRUCTIONS FOR USE AND CARE
DIAMONDS INSTRUCTIONS FOR USE AND CARE DIAMONDS, MULTI-USE, FRICTION GRIP Quala Diamonds are a rotary cutting device made of stainless steel and coated with diamond particles on the working end. It is
More informationAesculap Implant Systems
Aesculap Implant Systems Aesculap Implant Systems Spine USA Instructions for use/technical description Page 1 of 9 A 2 1 4 B 3 Page 2 of 9 USA Aesculap Implant Systems Instrument Legend A Rigid Inserter
More informationReprocessing Guide. Autoclavable Arthroscope and Hardware Sterilization Tray
Reprocessing Guide Autoclavable Arthroscope and Hardware Sterilization Tray 0233032116 Contents Introduction...2 Intended Use of Sterilization Trays...4 Warnings...5 Cautions...5 Instructions...6 Sterilization
More informationPreparation Instructions for the CAMLOG /CONELOG Implant System
J8000.0032 Rev.6 EN 06/2015 Preparation Instructions for the CAMLOG /CONELOG Implant System ENGLISH The following descriptions contain detailed instructions on cleaning, disinfection and sterilization
More informationAesculap Long and Short Ventriculoscope Systems Instructions for Use
Aesculap Long and Short Ventriculoscope Systems Instructions for Use INDICATIONS FOR USE Aesculap s short and long ventriculoscopes and associated instruments are designed for visual orientation and therapeutic
More informationSI-BONE ifuse Implant System Instruments Hospital Cleaning and Sterilization Instructions 0344
HOW SUPPLIED The SI-BONE instruments are supplied non-sterile and must be cleaned and sterilized prior to use. The ifuse Implant is provided separately and supplied sterile. Please refer to the ifuse System
More informationManufacturer s information
WARNINGS: Observe the standard German accident prevention regulations (UVV) We are not aware of any warnings if the instructions for the devices and disinfection and cleaning agents to be used are followed.
More informationProUltra ULTRASONIC SURGICAL TIPS
ProUltra ULTRASONIC SURGICAL TIPS EN FOR DENTAL USE ONLY DIRECTIONS FOR USE (ULTRASONIC SURGICAL TIPS) A0640 A0650 Satelec M3 x 0,6 EMS M3 x 0,5 ProUltra Surgical tips Ref. A0640 Ref. A0650 1) INDICATIONS
More informationa perfect fit INSTRUCTION MANUAL CAMLOG TORQUE WRENCH WITH CONTINUOUS TORQUE ADJUSTMENT Handling Sterilization Care
a perfect fit INSTRUCTION MANUAL CAMLOG TORQUE WRENCH WITH CONTINUOUS TORQUE ADJUSTMENT Handling Sterilization Care CAMLOG TORQUE WRENCH WITH CONTINUOUS TORQUE ADJUSTMENT INTRODUCTION The torque wrench
More informationRecommendations for cleaning, disinfection and sterilization of orthopaedic instruments and devices from Swemac.
Recommendations for cleaning, disinfection and sterilization of orthopaedic instruments and devices from Swemac. This document is intended as guidance for decontamination and sterilization for medical
More informationB&H SURGICAL. Laparoscopic Reference Guide. P.O. Box Santa Clarita, CA Toll Free: Ph: Fax:
B&H SURGICAL Laparoscopic Reference Guide P.O. Box 800192 Santa Clarita, CA 91380-0192 Toll Free: 800-971-9066 Ph: 661-257-0788 Fax: 661-257-0688 5mm Diameter Shaft NE300 Allis 12mm Jaw Length NE377 Babcock
More informationCARE AND MAINTENANCE O F S U R G I C A L A N D PROSTHETIC INSTRUMENTS
CARE AND MAINTENANCE O F S U R G I C A L A N D PROSTHETIC INSTRUMENTS w w w. c e r a r o o t. c o m Contents 3 Precise instruments 6 Be AWARE 7 Your responsability 8 Preoperative, intraoperative, and postoperative
More informationORTHODONTIC INSTRUMENTS
Swiss Quality and Reliability ORTHODONTIC INSTRUMENTS SWISS DENTAL SPECIALTIES Swiss Dental Specialties GmbH CH-6440 Brunnen Switzerland Phone +41 (0)41 810 42 42 Fax +41 (0)41 810 43 43 info@swissdentalspecialties.ch
More informationVelocity Orthopedics Instrument Cleaning and Sterilization
Velocity Orthopedics Instrument Cleaning and Sterilization It is important to read the Instructions For Use in its entirety prior to using the product. Caution: Federal law (USA) restricts this device
More informationUNICLIP DIRECTIONS FOR USE REF C226U - 0,8 MM / 1 MM FOR DENTAL USE ONLY. FISDR / F EN / 11 / updated 06/2016 1/7
UNICLIP FOR DENTAL USE ONLY DIRECTIONS FOR USE REF C226U - 0,8 MM / 1 MM EN FISDR / F19 02 31.EN / 11 / 2001 - updated 06/2016 1/7 1) Indications for use These products have to be used only in hospital
More informationEndoscopic Technology. Operating Manual. Cannula system
Endoscopic Technology Operating Manual AlphaPort Cannula system This manual contains proprietary information that is protected by copyright. All rights are reserved. This manual or excerpts thereof may
More informationHow clean are your instruments?
How clean are your instruments? Pre cleaning & preparation Samuel Morais Technical Director January 25 th 2015 Overview 1. Correct Preparation will result on good cleaning results that are visible and
More informationProUltra Ultrasonic Non Surgical Endo Tips
ProUltra Ultrasonic Non Surgical Endo Tips EN FOR DENTAL USE ONLY DIRECTIONS FOR USE (ULTRASONIC NON SURGICAL TIPS) A0620 A0621 A0630 A0631 Satelec M3 x 0,6 EMS M3 x 0,5 ProUltra Endo tips, Zirconium Ref.
More informationINSTRUMENT INSPECTION
INSTRUMENT INSPECTION CIS Self-Study Lesson Plan Lesson No. CIS 245 (Instrument Continuing Education - ICE) Sponsored by: by Donna Swenson, BS, CRCST, CHL, ACE, CSPDM President, Sterile Processing Quality
More informationCURVES. Anatomically Adaptable IPR strips. Brochure Instructions for use Processing instructions
CURVES Anatomically Adaptable IPR strips Brochure Instructions for use Processing instructions Visit us online! To learn more about all our orthodontic products plus many helpful user videos Innovative
More informationCleaning and disinfection Tonometer measuring prisms, contact lenses and Desinset
SVENSKA NEDERLANDS PORTUGUÊS ESPAÑOL ITALIANO FRANÇAIS DEUTSCH ENGLISH INSTRUCTIONS FOR USE Cleaning and disinfection Tonometer measuring prisms, contact lenses and Desinset 6. Edition / 2018 04 HAAG-STREIT
More informationINSTRUCTIONS FOR CLEANING, DISINFECTION AND STERILIZATION OF DFS INSTRUMENTS
Preparation (cleaning, disinfection and sterilization) of reusable rotating dental instruments General principles All instruments must be cleaned, disinfected and sterilized before each use; this applies
More informationM Manufacturer by: Guide for Cleaning, Sterilization and Storage of Instruments for Caldera Medical Desara Product Family of Implants
Guide for Cleaning, Sterilization and Storage of Instruments for Caldera Medical Desara Product Family of Implants M Manufacturer by: Caldera Medical, Inc. 5171 Clareton Drive Agoura Hills, CA 91301 U.S.
More informationTHE. Curve THE CURVE STRIPPING TOOL
THE Curve THE CURVE STRIPPING TOOL Innovative Product Made in Germany THE Curve Mastering the perfect curve Curvable polishing strips for interproximal reduction Sterilizable, double-sided diamond instruments
More informationHygienic Reprocessing
Hygienic Reprocessing HEINE UniSpec Instrument head General warning and safety information: WARNING! This symbol draws attention to a potentially dangerous situation. Non-observance can result in moderate
More informationSurgical Technique Guide
Surgical Technique Guide Flow-FX, LLC - 815.531.4424-9110 Darvin Drive, Mokena, IL 60448 - www.flow-fx.net Contents Implant Overview 1 Implant Features and Benefits 2 Instrument Overview 3 Surgical Technique
More informationRolimeter 50A. Operator s Manual for measuring anterior/posterior knee laxity
Rolimeter 50A Operator s Manual for measuring anterior/posterior knee laxity Rolimeter 50A 1 Contents Introduction................................................ 2 Design Philosophy..........................................
More informationEN MANUFACTURER S INFORMATION regarding the preparation of resterilisable medical devices complies with EN ISO 17664 Please read carefully! Medical devices which may be re-processed are tools for abutments
More informationThe A-Space SIBD Spinal System is a stand-alone device intended to be used with the four supplied bone screws if no supplemental fixation is used.
Instructions for Aesculap Implant Systems A-Space SIBD Spinal System Indications The A-Space SIBD Spinal System is a stand-alone device intended to be used with the four supplied bone screws if no supplemental
More informationBryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL
Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL Table of Contents Bryan-DUmon Series II rigid bronchoscope 1. 2. 3. 4. 5. Diagram and Overview Universal Barrel Bronchial and
More information1) INDICATIONS FOR USE These products have to be used only in hospital environments, clinics or dental offices by qualified dental personnel.
ProFile 04/06 & O.S. EN DENTAL USE ONLY DIRECTIONS FOR USE PROFILE 0) COMPOSITION The cutting part of these instruments is made of a nickel-titanium alloy. 1) INDICATIONS FOR USE These products have to
More informationQuality. Elegance. Innovation.
Quality. Elegance. Innovation. Triumph Orthodontic Instruments Quality and engineering come together for superior performance The Triumph Orthodontic Instrument line provides the orthodontic professional
More informationDISCLAIMER OF WARRANTY AND LIMITATION OF REMEDY
0086 Instructions for Use RCS Anterior Buttress Plate System Caution: Federal (USA) law restricts this device to sale by or on the order of a physician DISCLAIMER OF WARRANTY AND LIMITATION OF REMEDY There
More informationIt is recommended to use titanium coils. ph meter to control ph of the process. It is advised to use an automatic dosage for the maintenance products.
CRODA III Decorative Trivalent Chrome Process CRODA III is a hexavalent free chrome process, allowing to obtain slightly blue and bright deposits, optimal for decorative applications. ADVANTAGES Depuration
More informationDentium Surgery Kit Dental Implant Surgical Instrument Set
www.dentium.com Dentium Surgery Kit Dental Implant Surgical Instrument Set Dentium Surgery Kit is a cassette of surgical instruments for periodontal and dental implant surgery. The cassette is divided
More informationcare NCDC-Cleanser
Medical White Oil in an oil pen 24.950.12 Optimum cleaning with care As an instrument manufacturer the company Helmut Zepf developed a product line for the optimum processing of dental instruments, in
More informationPolicy x.xxx. Issued: Artificial Airways and Airway Care. ABC Home Medical Company Policy & Procedure Manual. A. Tracheostomy Tubes ( trach tubes)
A. Tracheostomy Tubes ( trach tubes) A tracheotomy is a surgical procedure whereby an opening is cut into the trachea of the patient for the purpose of inserting a tube (trach tube). The trach tube allows
More informationLBL-014. Rev
Package Insert Z- CLAMP ISP System Device Description: The Z-CLAMP ISP System is supplemental fixation device consisting of a variety of shapes and sizes of one-level lumbar and sacral plates and screws.
More informationChapter 5: Checking and Maintaining Ultrasound Equipment
Chapter 5: Checking and Maintaining Ultrasound Equipment Care and Cleaning (BB1564-AJ) Chapter 5: Checking and Maintaining Ultrasound Equipment 45 Ultrasound equipment requires regular checks and maintenance.
More informationAltus Product description / Instructions for Use IFU 6 Rev. 1
Content: 1 Introduction... 2 1.1 Legend... 2 1.2 Indication... 2 1.3 Contraindication... 2 1.4 Field of Application... 2 1.5 Sterilization... 2 1.6 Storage... 2 1.7 Allergies... 2 2 SYSTEM DESCRIPTION...
More informationAquaJogg Hydro Treadmill
AquaJogg Hydro Treadmill PART #: F-WXAQJG 330 LB. [150 kg] MAXIMUM WEIGHT CAPACITY MANDATORY LEAVE THIS MANUAL WITH TREADMILL OWNER To assemble your equipment read entire manual and follow all instructions.
More informationANATOMY OF A DENTAL INSTRUMENT
ANATOMY OF A DENTAL INSTRUMENT SCALERS & CURETTES All dental instruments follow basic design characteristics. The following diagrams outline the key principles of scaler and curette instrument design.
More informationAS Medizintechnik GmbH Sattlerstraße Tuttlingen Germany
Before using the intramedullary. please ensure that it is functioning properly and free of any defects. In addition, please follow these instructions, including the information regarding repair as wellas
More informationIntegra Total Foot System 2
Instructions for Use CAUTION: U.S. federal law restricts this device to sale by or on the order of a physician. Integra Total Foot System 2 DESCRIPTION The Integra Total Foot System (TFS2) is a system
More informationIN THE HEALTHCARE SETTING, GENERAL INSTRUMENTS REFER TO
CIS Self-Study Lesson Plan Lesson No. CIS 268 (Instrument Continuing Education - ICE) by Kristen Bursey, CRCST Sponsored by: General Instrumentation: An Overview LEARNING OBJECTIVES 1. Discuss the most
More informationTECHNICAL NOTE SURFACE PREPARATION GUIDE
TECHNICAL NOTE SURFACE PREPARATION GUIDE For high strength structural bonds, paint, oxide films, oils, dust, mould, release agents and all other surface contaminants must be completely removed. However,
More informationPENETRANT TESTING OF AEROSPACE MATERIALS
PREFERRED RELIABILITY PRACTICES PRACTICE NO. PT-TE-1426 PAGE 1 OF 6 PENETRANT TESTING OF AEROSPACE MATERIALS Practice: Penetrant testing improves hardware reliability by detecting surface flaws and defects
More informationSURGICAL TECHNIQUE GUIDE BRECKENRIDGE. Intervertebral Body/VBR Fusion System. ACDF Anterior Cervical Discectomy and Fusion
SURGICAL TECHNIQUE GUIDE TM BRECKENRIDGE Intervertebral Body/VBR Fusion System ACDF Anterior Cervical Discectomy and Fusion The following general Surgical Technique Guide is for illustrative purposes only.
More informationInstructions for Use Reform POCT System Caution: Federal (USA) law restricts this device to sale by or on the order of a physician
Instructions for Use Reform POCT System Caution: Federal (USA) law restricts this device to sale by or on the order of a physician DISCLAIMER OF WARRANTY AND LIMITATION OF REMEDY There is no express or
More informationINFORMATION TO THE PRODUCT RANGES. Instructions for Cleaning, Disinfection, Sterilization, Inspection and Maintenance of Medartis Products APTUS MODUS
INFORMATION TO THE PRODUCT RANGES Instructions for Cleaning, Disinfection, Sterilization, Inspection and Maintenance of Medartis Products APTUS MODUS Instructions for Cleaning, Disinfection, Sterilization,
More informationDISCLAIMER OF WARRANTY AND LIMITATION OF REMEDY
0086 Instructions for Use ShurFit Anterior Cervical Interbody Fusion System Caution: Federal (USA) law restricts this device to sale by or on the order of a physician DISCLAIMER OF WARRANTY AND LIMITATION
More informationCOMPRESSOR NEBULIZER MODEL: JB USER S MANUAL
COMPRESSOR NEBULIZER MODEL: JB0112-062 USER S MANUAL Read this manual before operating the nebulizer Save these instructions for future reference Caution: Federal law restricts this device to sale by or
More informationAquaJogg Hydro Treadmill
AquaJogg Hydro Treadmill PART #: F-WXAQJG 330 LB. [150 kg] MAXIMUM WEIGHT CAPACITY MANDATORY LEAVE THIS MANUAL WITH TREADMILL OWNER To assemble your equipment read entire manual and follow all instructions.
More informationInstructions for Use AccuFit Lateral Plate System Caution: Federal (USA) law restricts this device to sale by or on the order of a physician
Instructions for Use AccuFit Lateral Plate System Caution: Federal (USA) law restricts this device to sale by or on the order of a physician DISCLAIMER OF WARRANTY AND LIMITATION OF REMEDY There is no
More informationMASCOU FLUIDS 2017 CATALOG HIGH-GRADE QUALITY TAPPING AND CUTTING FLUIDS!
MASCOU FLUIDS 2017 CATALOG HIGH-GRADE QUALITY TAPPING AND CUTTING FLUIDS! AT THE EXCEPTION OF THE, MADE IN GERMANY MASCOU FLUIDS MASCOU-CUT SYNTHETIC EXCEPTIONAL PERFORMANCES! 100 % SYNTHETIC SOLUBLE CUTTING
More informationSURGICAL TECHNIQUE GUIDE BRECKENRIDGE. Intervertebral Body/VBR Fusion System. Oblique Lumbar Interbody Fusion
SURGICAL TECHNIQUE GUIDE BRECKENRIDGE TM Intervertebral Body/VBR Fusion System Oblique Lumbar Interbody Fusion The following general Surgical Technique Guide is for illustrative purposes only. As with
More informationAesculap Implant Systems
Aesculap Implant Systems Aesculap Implant Systems Spine USA Instructions for Use / Technical Description Arcadius XP C Instruments Page 1 of 28 USA Aesculap Implant Systems Arcadius XP C Instruments Page
More informationOBSOLETE. Visit for the latest version. Ankle Plating System 3 PKGI-79-B EFFECTIVE
Ankle Plating System 3 MediMark Europe Sarl. 11 rue Emile ZOLA. BP 2332 38033 GRENOBLE CEDEX 2 FRANCE +33.4.76.86.43.22 Acumed LLC 5885 NW Cornelius Pass Road Hillsboro, OR 97124-9432 +1.503.627.9957 acumed.net
More informationSelectTech 4.1 Bench. Assembly Manual
SelectTech 4.1 Bench Assembly Manual Table of Contents Important Safety Instructions...3 Safety Warning Labels and Serial Number...4 Specifications...5 Before Assembly...5 Parts...6 Hardware...7 Tools...7
More informationSelectTech 4.1 Bench Assembly / Owner s Manual
SelectTech 4.1 Bench Assembly / Owner s Manual This product is compliant with the applicable CE requirements. Table of Contents Important Safety Instructions...3 Safety Warning Labels and Serial Number...4
More informationASTM Workshop on Medical Device Cleanliness
ASTM Workshop on Medical Device Cleanliness Steve Goldstine Consultants SteveGoldstine@Yahoo.com 11/16/2010 ASTM: Cleanliness of Medical Devices ASTM Workshop on Medical Device Cleanliness Standard Practices
More informationTJF-160F/VF Cleaning and Disinfection Checklist
TJF-160F/VF Cleaning and Disinfection Checklist TJF-160F/VF Cleaning and Disinfection Checklist This checklist is used to evaluate and confirm if cleaning and disinfection of the TJF-160F/VF has been performed
More informationSIDEKICK EZ FRAME EXTERNAL FIXATION SYSTEM The following languages are included in this packet:
EN SIDEKICK EZ FRAME EXTERNAL FIXATION SYSTEM 149369-0 English (en) The following languages are included in this packet: For additional languages, visit our website www.wmt.com. Then click on the Prescribing
More informationTable of Contents. Introduction Indications For Use Contraindications Warnings Precautions...5
User Manual 3 Table of Contents Introduction....4 1. Indications For Use...4 2. Contraindications...4 3. Warnings...5 4. Precautions...5 5. Adverse Reactions...5 6. Step-By-Step Instructions...6 A. Contents...6
More informationEVOLVE TRIAD BONE SCREWS
EN EVOLVE TRIAD BONE SCREWS 146886-1 English (en) The following languages are included in this packet: For additional languages, visit our website www.wmt.com. Then click on the Prescribing Information
More informationRibLoc U Plus CHEST WALL PLATING SYSTEM FOR THE PERSONAL ATTENTION OF THE OPERATING SURGEON
ACUTE Innovations LLC RibLoc U Plus CHEST WALL PLATING SYSTEM FOR THE PERSONAL ATTENTION OF THE OPERATING SURGEON INSTRUCTIONS FOR USE DESCRIPTION The ACUTE Innovations RibLoc U Plus Chest Wall Plating
More informationMedescan Nebuliser Med - S600A Instructions Manual
Medescan Nebuliser Med - S600A Instructions Manual Please read this guidebook carefully before operating this unit Your Nebuliser is intended for use in the treatment of asthma, COPD and other respiratory
More informationGlobal Standards Engineering Policy & Procedure
Global Standards Engineering Policy & Procedure Revision History Number: G2-3 Section: G Subject: Liquid Penetrant Examination Procedure 1. SCOPE This procedure describes the technique, materials and acceptance
More informationChapter 8 ADMINISTRATION OF BLOOD COMPONENTS
Chapter 8 ADMINISTRATION OF BLOOD COMPONENTS PRACTICE POINTS Give the right blood product to the right patient at the right time. Failure to correctly check the patient or the pack can be fatal. At the
More informationConvalescent Kelly. Directions for Use
Convalescent Kelly Directions for Use 302-00001 2 Table of Contents Recommends 4 Items Included 4 Skills Taught 4 Airway System 5 Arms 6 Legs 6 Colon Reservoir 7 Genitalia 7 Urinary Catheterization and
More informationMANUAL FOR USE NO. 5 FLEXIBLE INTRAMEDULLARY REAMER REV ( GB ) non - sterile
MANUAL FOR USE NO. 5 FLEXIBLE INTRAMEDULLARY REAMER REV. 10.10.2013 ( GB ) non - sterile Before using the intramedullary reamer. please ensure that it is functioning properly and free of any defects. In
More informationREDUCING TEST BIAS IN EVALUATING REACH COMPLIANT PAINT SYSTEMS SAFRAN TECH (SAFRAN RESEARCH CENTER)
REDUCING TEST BIAS IN EVALUATING REACH COMPLIANT PAINT SYSTEMS NIHAD BEN SALAH, R&T MANAGER ADVANCED PROCESSES BAPTISTE FEDI, R&T ENGINEER ELECTROCHEMICAL PROCESSES VIRGINIE MATHIVET, STUDENT IN ENGINEERING
More informationDisinfection and Decontamination Core Subject. The Process of Instrument Decontamination
Disinfection and Decontamination Core Subject The Process of Instrument Decontamination Aims: To give an overview of the processes involved in dental instrument decontamination using essential quality
More informationAesculap Spine Instructions for use
Aesculap Spine S 4 Spondylolisthesis Reduction Instrument (SRI) Instructions for use S 4 Spondylolisthesis Reduction Instrument (SRI) 5 4 3 2 Fig. 1 1 9 10 11 8 6 7 Fig. 2 Aesculap Spine S 4 Spondylolisthesis
More informationCleaning and Care Instructions
Cleaning and Care Instructions Westmed recommends that principles and practices related to cleaning and disinfection of nebulizers and related respiratory equipment, as published in the Infection Prevention
More informationREDUCT Headless Compression Screw System
REDUCT Headless Compression Screw System INSTRUCTIONS FOR USE : For use by physicians only. Federal Law restricts this device to sale by or on the order of a physician. Failure to follow instructions may
More informationUSER SPECIFICATIONS FOR QUINTOLUBRIC 888 Series DESCRIPTION OF THE MOST IMPORTANT PROPERTIES AND THE POSSIBLE VARIATIONS AND TOLERANCES
USER SPECIFICATIONS FOR QUINTOLUBRIC 888 Series OVERVIEW The QUINTOLUBRIC 888 Series of fluids are based on a synthetic organic ester, which is the main base component, plus a number of selected additives
More informationSYMBOLOGY. = Manufacturer. = Manufacturing Serial Number. = Manufacturing Lot Number = Catalog Number LOT REF. = Do not resterilize Single Use Only
damage or expenses directly or indirectly arising from use of this product. This warranty is in lieu of and excludes all other warranties not expressly set forth herein, whether express or implied by operation
More informationATHLET VBR. The real winner. VBR in PEEK-OPTIMA PRODUCT INFORMATION
ATHLET VBR in PEEK-OPTIMA The real winner PRODUCT INFORMATION VBR PRODUCT INFORMATION The Concept A vertebral body replacement requires top performance Simple intra- and postoperative control Anatomic
More informationPeninsula Dental Social Enterprise (PDSE)
Peninsula Dental Social Enterprise (PDSE) Decontamination - Cleaning and Disinfection Version 3.0 Date approved: November 2016 Approved by: The Board Review due: November 2019 Policy will be updated as
More informationTuberculocidal 2-Minute Hard, Non-porous Surface Disinfectant
70144-1-51003_Birex Quat_20180911_11_51003_.pdf Fragrance REORDER NO. 296000 See back panel for First Aid and additional Precautionary Statements Net Contents: 24 fl. oz. (710 ml M60059-84561A-0118 11-2016
More informationFor use by an Accredited Orthopaedic Surgeon only
Page 1 of 5 For use by an Accredited Orthopaedic Surgeon only 1. Purpose: External fixators are intended to aid in surgical stabilization following operative procedures to treat fractures, enable correction
More information7.2.7 Analytical Techniques
7.2.7 Analytical Techniques 55 minutes 59 marks Page 1 of 20 Q1. A company making sweets uses different colour additives in different countries. In some countries the company uses Allura Red to colour
More informationEngineering Materials
Engineering Materials PREPARED BY Academic Services August 2011 Applied Technology High Schools, 2011 Module Objectives After the completion of this module, the student will be able to: Explain the basic
More informationE-type Straight Nose Cone
OPERATION MANUAL E-type Straight Nose Cone Please read this Operation Manual carefully before use and file for future reference. Caution This handpiece is intended for use by dental professionals only.
More informationINSTRUMENT MANAGEMENT CHAIRSIDE PRACTICE MORE CLEANING HU-FRIEDY CASSETTES & STORAGE STERILIZATION
INSTRUMENT MANAGEMENT CHAIRSIDE PRACTICE MORE CLEANING STORAGE STERILIZATION HU-FRIEDY CASSETTES & INSTRUMENT MANAGEMENT IT S EASY TO GET STARTED IMS is the first step in helping you meet your growth objectives.
More informationNondestructive Testing Procedure: Liquid Penetrant Testing
MOGAS INDUSTRIES, INC. Nondestructive Testing Procedure: Liquid Penetrant Testing Specification: NDT 0200 Version: 2.0 November 10, 2014 Approved by: Signature Paul T. Marks Consulting Level III ACCP Professional
More informationMaxillofacial Patient Information Leaflet
Denture Care Maxillofacial Patient Information Leaflet Your New Dentures New complete or partial dentures will feel strange. You must expect a period of awkwardness while you are getting used to them.
More informationORTHOLOC 3Di PLANTAR LAPIDUS PLATE
ORTHOLOC 3Di PLANTAR LAPIDUS PLATE 152130-0 The following languages are included in this packet: English (en) Deutsch (de) Nederlands (nl) Français (fr) Español (es) Italiano (it) Português (pt) 中文 - Chinese
More informationThe fitting process of SomnoGuard AP. Hints to complement the user instructions
The fitting process of SomnoGuard AP Hints to complement the user instructions Essential equipment and instruments Spray disinfectant for all instruments Boling water bath Water boiler Disposable gloves
More informationEnglish G EMINU S Select Distal Radius S ystem INSTRUCTIONS FOR USE
English G EMINU S Select Distal Radius S ystem INSTRUCTIONS FOR USE : For use by physicians only. Caution: Federal Law restricts this device to sale by or on the order of a physician. Failure to follow
More informationPrinciples and Techniques of Disinfection
Principles and Techniques of Disinfection Chapter 20 Copyright 2018, Elsevier Inc. All Rights Reserved. 1 Learning Objectives Lesson 20.1: Principles and Techniques of Disinfection 1. Pronounce, define,
More informationProduct Information Dairy
Product Information Dairy February 2010 alcaline cleaning description main ingredients calgonit R flüssig Concentrated caustic detergent, non Caustic, stabilizers foaming. Canbecombinedwithactive chlorine.
More informationStraumann ProClean Cassette. Basic Information on the
Straumann ProClean Cassette Basic Information on the Straumann ProClean Cassette Contents 1. Straumann ProClean Cassette Uncompromised hygiene 2 2. Straumann ProClean Cassette product at a glance 3 2.1
More informationYasargil Permanent Aneurysm Clips
Yasargil Permanent Aneurysm Clips Yasargil aneurysm clips Figure captions 1 Yasargil Phynox aneurysm clip, example of a straight clip 2 Yasargil titanium aneurysm clip, example of a straight clip 3 Yasargil
More informationGUIDELINES FOR PROCESSING CELTRA DUO
GUIDELINES FOR PROCESSING CELTRA DUO 2 CONTENTS Minimum wall thickness 4 CAD / CAM processing 5 Finishing / polishing 5 Staining and glazing 5 Firing recommendations 8 Cementing 9 Ordering information
More informationISO 9001 EN ISO Digital Pneumatic Tourniquet system CUFF USER MANUAL
ISO 9001 EN ISO 13485 Digital Pneumatic Tourniquet system CUFF USER MANUAL 1. Intended use Tourniquet cuffs intended to occlude the blood flow to obtain hemostasis field during limb surgery. 2. Warning
More informationMidwest E Motor. Directions For Use. Doc. No
Midwest E Motor Directions For Use CAUTION: US Federal law restricts this device to sale by or on the order of a licensed dental professional. Doc. No. 87513-0814 All trademarks referred to are the property
More information