The measurements of pleural fluid WBC count

Size: px
Start display at page:

Download "The measurements of pleural fluid WBC count"

Transcription

1 Variations in Pleural Fluid WBC Count and Differential Counts With Different Sample Containers and Different Methods* Barrett D. Conner, MD; Y. C. Gary Lee, MD; Paul Branca, MD, FCCP; Jeffrey T. Rogers, RRT; R. Michael Rodriguez, MD; and Richard W. Light, MD, FCCP Objective: To compare the results of pleural fluid analysis for WBC counts and differential cell counts as follows: (1) counting performed manually vs that performed by an automated cell counter; (2) cells collected in different types of specimen containers; and (3) cell counts performed at 4 and 24 h postthoracentesis. Methods: Twenty-eight pleural fluid samples were each collected in five different containers (ie, ethylenediaminetetraacetic acid (EDTA)-treated glass, citrate-treated glass, heparinized glass, plain glass, and plain plastic tubes). The WBC counts and differential cell counts were obtained manually (on the EDTA tube) and with an automated counter on all tubes within4hofcollection, and again after 24 h of refrigeration. Results: There was a close correlation between the WBC counts obtained manually and those obtained with the automated counter from the pleural fluid samples collected in the EDTA tubes (r 0.92). With the automated counter, the pleural fluid WBC counts were similar among the three tubes containing anticoagulants, but the counts obtained from the tubes without anticoagulants were significantly lower. The differential cell counts obtained manually and those obtained with the automated cell counter differed substantially. Although the percentage of lymphocytes was similar, the automated counter was inaccurate in differentiating neutrophils from large monocytes or mesothelial cells. The WBC counts obtained within 4hofcollection and 24 h after collection were virtually identical. Conclusions: The WBC counts obtained manually and with the automated counter from pleural fluid samples in EDTA tubes correlated very closely. The pleural fluid WBC count was lower if the pleural fluids had been collected in tubes without an anticoagulant. Automated WBC counts from pleural fluid specimens were inaccurate, possibly due to difficulty in separating neutrophils from monocyte/mesothelial cells. Refrigerated storage for up to 24 h had no significant effect on the total WBC count or on the WBC count differential regardless of the tube utilized. (CHEST 2003; 123: ) Key words: cell counts; differential; pleural fluid; thoracentesis Abbreviations: CSF cerebrospinal fluid; EDTA ethylenediaminetetraacetic acid The measurements of pleural fluid WBC count and differential count are helpful in the diagnosis and management of patients with pleural effusion. In general, a WBC count of 1,000 cells/ L suggests an exudate, while most transudates have WBC counts of 1,000 cells/ L. Parapneumonic effusions usually have WBC counts of 10,000 cells/ L, *From the Department of Pulmonary Medicine, Saint Thomas Hospital and Vanderbilt University, Nashville, TN. This research was supported by The Saint Thomas Foundation, Nashville, TN, and Bayer Corporation, Tarrytown, NY. Manuscript received July 11, 2002; revision accepted September 24, however, similar WBC counts are also seen in pleural effusions that are related to pancreatitis, pulmonary infarction, collagen vascular diseases, malignancy, and tuberculosis. 1,2 The WBC count differential is one of the most informative tests performed on pleural fluid samples and can aid significantly in identifying the etiology of Reproduction of this article is prohibited without written permission from the American College of Chest Physicians ( permissions@chestnet.org). Correspondence to: Richard W. Light, MD, FCCP, Director of Pulmonary Disease Program, St. Thomas Hospital, 4420 Harding Rd, Nashville, TN 37202; rlight98@yahoo.com CHEST / 123 / 4/ APRIL,

2 many effusions. 2 A predominance of neutrophils in an exudative pleural fluid sample indicates acute inflammation of the pleural surface, as can be seen in pneumonia, pulmonary embolism, subphrenic abscess, early tuberculosis, and also pancreatitis. The discovery of an exudative effusion with 50% small lymphocytes is suggestive of a malignant disease, tuberculous pleuritis, or a pleural effusion after coronary artery bypass graft surgery. If a large percentage of lymphocytes is found, the pleural fluid may be sent for flow cytometry to determine whether a clonal cell population is present, as is seen in lymphoma. Mesothelial cells line the pleural cavity, become dislodged, and are a normal part of pleural effusions. Their presence or absence is useful diagnostically as they are usually absent in tuberculous pleural effusions and complicated parapneumonic effusions. These conditions are associated with a marked inflammatory response that covers the pleura and prevents the shedding of mesothelial cells into the pleural fluid. Eosinophils in the pleural fluid are most often the result of either air or blood in the pleural space. Other unusual diagnoses to consider in the presence of pleural fluid eosinophilia include asbestos-related diseases, drug reactions, or parasitic diseases such as paragonimiasis, hydatid disease, amebiasis, or ascariasis. 3 A recent review of the English medical literature, revealed no published data with regard to standards for pleural fluid collection and transport for the determination of the WBC counts and differential cell counts. Moreover, there are no data regarding changes in the measured WBC counts or differential cell counts in pleural fluid specimens over time. Currently, at our institution, pleural fluids for WBC count determination and differential cell counts are submitted in tubes that have been anticoagulated with ethylenediaminetetraacetic acid (EDTA), citrate, or heparin, and in plastic or glass tubes without anticoagulants. At most hospitals, cell counts and differential counts of body fluid samples are performed manually. Manual cell counts are dependent on the availability of skilled laboratory personnel, are costly, and often are available only during certain hours, making delays in cell count determinations common. Clearly, an alternative to manual cell counting that is accurate, expeditious, easily obtained, and more costefficient is attractive. The present study had the following three objectives: (1) to determine whether the pleural fluid WBC count and differential count, as determined by an automated cell counter, are comparable to the pleural fluid WBC count and differential count determined manually; (2) to compare the pleural fluid WBC count and differential count obtained using samples collected in tubes of varying composition and with varying anticoagulants (ie, EDTAtreated glass, heparinized glass, citrate-treated glass, plain glass, and plain plastic tubes); and (3) to compare the measured WBC counts and differential counts from the various tubes measured within 4 h of collection and at 24 h postcollection. Our hypotheses were as follows: (1) accurate pleural fluid WBC counts and differential counts could be obtained using the automated cell counter; (2) tubes containing an anticoagulant would provide more accurate pleural fluid WBC counts and differential counts than tubes without anticoagulants, because the cells might clump if no anticoagulant was present; and (3) a 24-h delay in performing WBC counts and differential counts on pleural fluid samples would not significantly affect the result. Materials and Methods Between March 16, 1999, and April 14, 1999, we prospectively studied 28 pleural fluid samples from 26 patients who had undergone thoracentesis under ultrasound guidance in the Department of Radiology. The study was approved by the Institutional Review Board of Saint Thomas Hospital, and written informed consent was obtained from each patient. The pleural fluid was obtained using a 17-gauge needle with a plastic catheter, the placement of which was directed under ultrasound guidance. Portions of each pleural fluid sample were placed in EDTA-treated, citrate-treated, heparinized, and plain glass tubes, as well as in the plain plastic tubes found in commercially available thoracentesis kits (Baxter; Deerfield, IL). The samples were refrigerated at 4 C until the WBC counts and differential counts were obtained. The pleural fluid WBC count and differential count from each of the tubes was determined within4hofthepatient undergoing thoracentesis, and again was performed at 24 h postthoracentesis using an automated cell counter (ADVIA-120; Bayer; Tarrytown, NY). Manual WBC counts and differential counts also were performed using a Neubauer hemocytometer (American Optical; Buffalo, NY), and a Wright stained blood smear, respectively, on the samples collected in the EDTA-treated glass tubes within 4 h of collection, and they were used as reference values. Statistical Analysis All data were analyzed with a statistics software program (Sigma Stat, version 3.0; Jandel Scientific; San Rafael, CA). The manual and automated WBC counts were compared using a paired t test and linear regression. The WBC counts in the five different tubes were compared utilizing the one-way analysis of variance with repeated measures. Results with p 0.05 were considered to be significant. Total WBC Count Results The total pleural fluid WBC counts obtained with manual and automated counting methods on the 1182 Clinical Investigations

3 EDTA-treated fluid samples were nearly identical (r 0.92; p 0.001) [Fig 1]. When the total WBC counts of the pleural fluids collected in the five different tubes were determined by the automated counter, there were significant differences (Table 1). The median cell counts obtained from the specimens in the plastic tubes and in the glass tubes were significantly (p 0.05) lower than those obtained in the EDTA-treated tubes. The median cell count in the glass tubes was only 55% of the median cell count in the EDTA-treated tubes. Moreover, the reduction in the cell count from patient to patient was not consistent (Fig 2), as some of the values approached 100% while others were 25%. When the three tubes with anticoagulation were compared, the citrate-treated tubes and heparinized tubes had significantly lower median WBC counts than the EDTA-treated tubes, but their median values were higher than those of the glass tubes. Manual vs Automated Pleural Fluid WBC Differential Counts In contrast to the results from the total pleural fluid WBC counts, the differential cell counts obtained manually and with the automated method were not closely correlated when the samples from the EDTA-treated tubes were compared. For example, the correlation coefficient between the percentage of neutrophils determined manually and that determined with the automated machine was only 0.63, with a standard error of the estimate of 12.8% (Fig 3, top). In addition, the correlation coefficient between the percentage of mononuclear/mesothelial cells determined by the two methods was only 0.19 with a standard error of the estimate of 12.5% (Fig 3, Table 1 Automated Total WBC Counts From Various Collection Tubes (n 28)* Tube Median 25% 75% EDTA ,636.1 Heparin ,151.2 Citrate ,235.3 Plastic ,889.8 Glass ,172.8 *Values given as cells/ L. Significantly different compared to EDTA. middle). However, there was an excellent correlation between the percentage of lymphocytes determined by the two methods (r 0.92) [Fig 3, bottom]. The pleural fluid differential cell counts determined with the automated counter from the five different tubes differed significantly (Table 2). In general, the neutrophil percentage and the mononuclear/mesothelial percentage tended to be higher in the EDTA-treated tubes, while the lymphocyte percentage and the eosinophil percentage tended to be lower in the EDTA-treated tubes. In general, the correlation coefficients were higher among the counts obtained using samples in the five different tubes with the automated counter than among the counts obtained with the automated counter and manual counting (Table 3). Nevertheless, the correlation coefficients obtained among the counts obtained using the five different tubes with the automated counter were frequently Effect of Storage on Pleural Fluid WBC Counts When the automated cell counts were repeated at 24 h and compared to the initial automated WBC Figure 1. Total WBC counts from EDTA-treated samples using automated and manual counting methods. Figure 2. Automated WBC counts from samples in EDTAtreated tubes vs those from glass tubes. CHEST / 123 / 4/ APRIL,

4 counts from similar tubes (eg, EDTA-treated or citrate-treated), there were virtually no differences (Table 4). When the differential cell counts that had been obtained initially and at 24 h using the automated cell counter were compared, the correlations were also good, except for the counts with the glass tubes (Table 4). Therefore, a 24-h delay in determining pleural fluid cell counts is acceptable, unless one is using glass tubes that have not been treated with an anticoagulant. Discussion Figure 3. Top: pleural fluid neutrophil counts of samples stored in EDTA-treated tubes using manual vs automated counting methods. Middle: pleural fluid monocyte/mesothelial cell counts of samples stored in EDTA-treated tubes using manual vs automated counting methods. Bottom: pleural fluid eosinophil counts of samples stored in EDTA-treated tubes using manual vs automated counting methods. The present study shows that the pleural fluid WBC counts obtained with manual and automated counting methods on the EDTA-preserved fluid samples were nearly identical. However, the tube in which the fluid was collected influenced the WBC count determined with the automated counter. The median cell counts from samples collected in tubes without anticoagulant treatment (ie, glass and plastic tubes) were significantly lower than those in samples collected in EDTA-treated tubes, with the median cell counts in glass tubes being only 55% of those in the EDTA-treated tubes. The differential cell counts obtained with the automated counter when compared to those obtained manually were not sufficiently accurate for clinical use. There was no significant change in the WBC counts or the differential cell counts when these measurements were delayed for 24 h. Since their introduction, automated cell counters have become indispensable instruments in the clinical laboratory for the analysis of blood samples. However, analyses of other body fluids are currently performed manually. Manual counting is a costly, time-consuming, labor-intensive laboratory procedure, which is dependent on the availability of skilled laboratory personnel. Moreover, the manual method of determining the WBC differential count has been shown to be imprecise and inaccurate in studies comparing results to a reference differential counting method. 4 Sampling error is the major cause of the imprecise measures, due to the relatively small numbers of cells counted manually. In order to achieve an acceptable degree of precision, at least 1,000 cells should be counted. 5 The modern automated cell counters are capable of performing 100 complete hematologic cell counts in an hour, greatly diminishing the hours of labor utilized. Since the automated cell counter analyzes 1,000 to 20,000 leukocytes from each sample, the accuracy and the reproducibility of the results are superior to counts obtained manually when only 100 cells are counted Clinical Investigations

5 Table 2 Automated Pleural Fluid WBC Differential Count Determined Within 4 h of Collection Neutrophils, % Lymphocytes, % Monocytes/Mesothelial Cells, % Eosinophils, % Tube Median 25% 75% Median 25% 75% Median 25% 75% Median 25% 75% EDTA 24* Citrate 20.7* Heparin Plastic Glass *Significantly different compared to plastic. Significantly different compared to heparin, glass, and plastic. The new generation of cell analyzers utilizes variations of flow cytometry alone or in combination with other modalities. The cell analyzer used in the present study (ADVIA 120; Bayer) obtained the WBC count by passing a column of cells, after the RBCs underwent hemolysis, through an orifice where they were counted using two-angle laser light scatter signals. The differential cell count with the cell analyzer used in the present study was obtained using the Perox method. With this method, the cells are initially incubated with a peroxidase solution that stains the granules. Then the cell suspension is passed through the flow cell where the absorption (peroxidase staining) and the forward light-scatter (size) of each WBC are measured. Then each cell is identified as a neutrophil, lymphocyte, monocyte, eosinophil, basophil, or large unstained cell from its position on a cytogram on which the peroxidase staining is plotted on the x-axis and the volume is plotted the y-axis. For the present study, the monocytes and the large undifferentiated cells were combined for the monocyte/mesothelial cell population. To date, automated cell counters have been utilized mostly for the analysis of blood. However, this technology is also utilized in many automated urine analyzers, which provide for the cell counting of urine sediment. 6,7 The automated particle- Table 3 Pearson Product Moment Correlation for Automated Differential Cell Counts from the Various Cell Types and Tubes* Cell Type Auto EDTA Auto Citrate Auto Heparin Auto Glass Auto Plastic Neutrophils Manual EDTA (0.011) Auto EDTA Auto citrate Auto heparin Auto glass Lymphocytes Manual EDTA Auto EDTA Auto citrate Auto heparin Auto glass Monocytes/mesothelial cells Manual EDTA Auto EDTA Auto citrate Auto heparin Auto glass Eosinophils Manual EDTA Auto EDTA Auto citrate Auto heparin Auto glass *Values given as r values. All p values were 0.001, unless otherwise indicated. Auto count performed with automated counter; Manual manual counting performed. p Values were not significant. CHEST / 123 / 4/ APRIL,

6 Table 4 Pearson Correlation Values for Total WBC and Differential Count Cell Types Determined With the Automated Counter Initially and After 24 h of Storage at 4 C* Tube Total WBC Count Monocytes/ Mesothelial Cells Neutrophils Lymphocytes Eosinophils EDTA Citrate Heparin Glass Plastic *Values given as r values. flow cytometers are more accurate and use less labor than visual microscopy. 8 There have been few reported studies using automated cell counters for cell counts and differential counts of other body fluids. Ziebig and coworkers 9 compared counts obtained with a hematology analyzer (Cell-Dyn 3500; Abbott Laboratories; Abbott Park, IL) and a urine flow cytometer (UF-100; Sysmex Corporation; Long Grove, IL) with counts obtained manually. They reported that in most cases the WBC counts from cerebrospinal fluid (CSF) were similar, but in CSF samples with high lymphocyte counts, the hematology analyzer gave a falsely high WBC count while the flow cytometer gave a falsely low rate. Van Acker and coworkers 10 reported similar results from the CSF samples using the urine flow cytometer (UF-100). However, Aune and Sandberg 11 reported that the automated cell counter (model H*2; Bayer) could replace visual microscopy in the analysis of CSF. Salinas and colleagues 12 compared manual and automated WBC cell counts in 100 EDTApreserved synovial fluid samples. They reported that the correlation coefficient between the two different methods was In addition, they found that on repeated measures of the same sample, the coefficient of variation was less for the automated counts than for the manual. The present study demonstrates that the total WBC counts from pleural fluid samples determined manually and using the automated counter are nearly identical when the fluids were collected in EDTAtreated tubes. It is noteworthy, however, that the total WBC count determined with the automated counter was dependent on the tube in which it was collected. If the pleural fluid had undergone anticoagulation, there was no significant difference in the total WBC count. However, the total WBC counts were significantly lower if the fluid had been collected in plastic or glass tubes without receiving anticoagulation (Table 2). The counts were nearly identical in the tubes with and without the anticoagulant for some specimens, while they were much lower in the tubes without the anticoagulant for other specimens (Fig 2). We speculate that lower counts in the tubes without anticoagulants were due to cell clumping. For determining a pleural fluid WBC count, we recommend that the fluid be collected in a tube with an anticoagulant, as opposed to the plain plastic tubes that are found in most commercially available thoracentesis kits. The present study demonstrates that the differential cell count obtained with the automated counter differed significantly from the differential cell count obtained manually from the specimens preserved with EDTA (Fig 3). The primary problem appeared to be in differentiating the neutrophils from the monocyte/mesothelial cells. The automated counter both overcounted and undercounted the percentage of monocyte/mesothelial cells. This problem could possibly be corrected if the assignment of cells on the cytogram were changed. The tube in which the specimen was collected influenced the differential cell count obtained with the automated counter. There was a higher percentage of neutrophils and monocyte/mesothelial cells and a lower percentage of lymphocytes in the EDTA-preserved specimen than in the other specimens. This observation suggests that the anticoagulant in the tube affects either the cell size or the peroxidase staining. An alternative explanation would be that there was clumping of the cells. If the cells other than the lymphocytes clumped and several cells that were clumped together were counted as one cell, then the percentage of lymphocytes would increase. In the present study, the WBC counts obtained initially and after a delay of 24 h were virtually identical. These findings are compatible with those reported 12 when cell counters have been used to determine the WBC count using samples of blood and synovial fluids. In conclusion, the present study documents that the pleural fluid WBC counts obtained manually and with an automated cell counter from specimens preserved with EDTA were virtually identical. When the WBC count of a pleural fluid is being determined, the fluid should be anticoagulated because the WBC count is lower in plain plastic or glass tubes, presumably due to cell clumping. The pleural fluid WBC count is not affected if the fluid is stored for 24 h. Differential cell counts from pleural fluid samples that were determined with the automated cell counter were not sufficiently accurate for clinical use Clinical Investigations

7 References 1 Light RW, Macgregor MI, Luchsinger PC, et al. Pleural effusions: the diagnostic separation of transudates and exudates. Ann Intern Med 1972; 77: Light RW, Erozan YS, Ball WC Jr. Cells in pleural fluid: their value in differential diagnosis. Arch Intern Med 1973; 132: Light R. Pleural diseases. 4th ed. Philadelphia, PA: Lippincott Williams & Wilkins, 2001; Dotson M, Koepke J. Description and manual method performance vs. reference method. Paper presented at: NCCLS Differential Count Symposium, November 26 28, 1984, Arlington, VA 5 Krause JR. The automated white blood cell differential: a current perspective. Hematol Oncol Clin North Am 1994; 8: Fenili D, Pirovano B. The automation of sediment urinalysis using a new urine flow cytometer (UF-100). Clin Chem Lab Med 1998; 36: Hannemann-Pohl K, Kampf S. Automation of urine sediment examination: a comparison of the Sysmex UF-100 automated flow cytometer with routine manual diagnosis (microscopy, test strips, and bacterial culture). Clin Chem Lab Med 1999; 37: Delanghe J, Kouri T, Huber A, et al. The role of automated urine particle flow cytometry in clinical practice. Clin Chim Acta 2000; 301: Ziebig R, Lun A, Sinha P. Leukocyte counts in cerebrospinal fluid with the automated hematology analyzer CellDyn 3500 and the urine flow cytometer UF-100. Clin Chem 2000; 46: Van Acker J, Delanghe J, Langlois M, et al. Automated flow cytometric analysis of cerebrospinal fluid. Clin Chem 2001; 47: Aune M, Sandberg S. Automated counting of white and red blood cells in the cerebrospinal fluid. Clin Lab Haematol 2000; 22: Salinas M, Rosas J, Iborra J, et al. Comparison of manual and automated cell counts in EDTA preserved synovial fluids: storage has little influence on the results. Ann Rheum Dis 1997; 56: CHEST / 123 / 4/ APRIL,

Comparison of Pleural Fluid ph Values Obtained Using Blood Gas Machine, ph Meter, and ph Indicator Strip*

Comparison of Pleural Fluid ph Values Obtained Using Blood Gas Machine, ph Meter, and ph Indicator Strip* Comparison of Pleural Fluid ph Values Obtained Using Blood Gas Machine, ph Meter, and ph Indicator Strip* Dong-sheng Cheng, MD; R. Michael Rodriguez, MD; Jeffrey Rogers, RRT; Marvin Wagster; DanielL. Starnes,

More information

Evaluation of the Abbott CELL-DYN 4000 Hematology Analyzer

Evaluation of the Abbott CELL-DYN 4000 Hematology Analyzer Hematopathology / EVALUATION OF THE ABBOTT CELL-DYN 4 HEMATOLOGY ANALYZER Evaluation of the Abbott CELL-DYN 4 Hematology Analyzer Ernesto Grimaldi, MD, and Francesco Scopacasa, PhD Key Words: Abbott CD

More information

Detail PRINCIPLE: Body fluids other than blood and urine will be analyzed according to their site of origin, and the providers specific orders.

Detail PRINCIPLE: Body fluids other than blood and urine will be analyzed according to their site of origin, and the providers specific orders. Subject Body Fluid Analysis - Affiliate Index Number Lab-8760 Section Laboratory Subsection Regional/Affiliates Category Departmental Contact Munson, Karen Last Revised 6/28/2017 References Required document

More information

Determination of hemoglobin is one of the most commonly

Determination of hemoglobin is one of the most commonly ORIGINAL ARTICLE Multiple-Site Analytic Evaluation of a New Portable Analyzer, HemoCue Hb 201+, for Point-of-Care Testing Sten-Erik Bäck, PhD,* Carl G. M. Magnusson, PhD, Lena K. Norlund, MD, PhD, Henning

More information

MLAB 1211 Body Fluids BF Differentials - pretest

MLAB 1211 Body Fluids BF Differentials - pretest MLAB 1211 BF Differentials - pretest Instructor: Carolyn Ragland MLAB 1211 pre-test #2 Spring No Extra Materials Needed Name Date Instructions: Neatly write your answer in the space provided. Unless otherwise

More information

2008 CAP TODAY Q & A

2008 CAP TODAY Q & A 2008 CAP TODAY Q & A Q. How often should we document hematology competencies to ensure consistency of morphologic observations for manual differentials and fluids? Should we do this every six months or

More information

Management of Pleural Effusion

Management of Pleural Effusion Management of Pleural Effusion Development of Pleural Effusion pulmonary capillary pressure (CHF) capillary permeability (Pneumonia) intrapleural pressure (atelectasis) plasma oncotic pressure (hypoalbuminemia)

More information

THE USE OF PLEURAL FLUID CHOLESTEROL IN IDENTIFYING THE TYPE OF PLEURAL EFFUSION

THE USE OF PLEURAL FLUID CHOLESTEROL IN IDENTIFYING THE TYPE OF PLEURAL EFFUSION THE USE OF PLEURAL FLUID CHOLESTEROL IN IDENTIFYING THE TYPE OF PLEURAL EFFUSION Hyacinth D. Jumalon, MD, DPCP West Visayas State University Medical Center Iloilo City Region VI introduction - The first

More information

Validation of the Efficacy of a Practical Method for Neutrophils Isolation from Peripheral Blood

Validation of the Efficacy of a Practical Method for Neutrophils Isolation from Peripheral Blood Validation of the Efficacy of a Practical Method for Neutrophils Isolation from Peripheral Blood JONATHAN DEGEL, MASIH SHOKRANI OBJECTIVE: The objectives of this study were to validate the Polymorphprep

More information

To study the combined use of pleural fluid lymphocyte/ neutrophil ratio and ADA for the diagnosis of tuberculous pleural effusion

To study the combined use of pleural fluid lymphocyte/ neutrophil ratio and ADA for the diagnosis of tuberculous pleural effusion and ADA for the diagnosis of tuberculous. IAIM, 2017; 4(9): 1-5. Original Research Article To study the combined use of fluid lymphocyte/ neutrophil ratio and ADA for the diagnosis of tuberculous Ramasamy

More information

Preechaya Wongkrajang, M.D., Chaicharoen Tantanate, M.D. ABSTRACT

Preechaya Wongkrajang, M.D., Chaicharoen Tantanate, M.D. ABSTRACT OriginalArticle Comparison of Leukocyte Differential Count by Beckman Coulter Unicel DxH800, Beckman Coulter LH780 and Sysmex XE-5000 Preechaya Wongkrajang, M.D., Chaicharoen Tantanate, M.D. Department

More information

Performance evaluation of Celltac G: a new automated hematology analyzer

Performance evaluation of Celltac G: a new automated hematology analyzer Original Article Performance evaluation of Celltac G: a new automated hematology analyzer Masaaki Sugiyama 1, Tsukasa Kobayashi 1, Yuki Jisyage 2, Shigeko Yamamoto 2, Yutaka Nagai 2,3 and Hiroshi Kondo

More information

Changes in Automated Complete Blood Cell Count and Differential Leukocyte Count Results Induced by Storage of Blood at Room Temperature

Changes in Automated Complete Blood Cell Count and Differential Leukocyte Count Results Induced by Storage of Blood at Room Temperature Changes in Automated Complete Blood Cell Count and Differential Leukocyte Count Results Induced by Storage of Blood at Room Temperature Gene L. Gulati, PhD; Lawrence J. Hyland, MD; William Kocher, MD;

More information

Literature List Body Fluids

Literature List Body Fluids Literature List Body Fluids Customer Information March 2018 Date: March 2018 Subject: Literature List body fluids Issued by: Scientific Customer Services Number: 180312 Note: Whether references are given

More information

Abbott Cell-Dyn Reticulocyte Method Comparison and Reticulocyte Normal Reference Range Evaluation

Abbott Cell-Dyn Reticulocyte Method Comparison and Reticulocyte Normal Reference Range Evaluation Laboratory Hematology 8:85-90 2002 Carden Jennings Publishing Co.. Ltd. Abbott Cell-Dyn Reticulocyte Method Comparison and Reticulocyte Normal Reference Range Evaluation T. SCHISANO, L. VAN HOVE Abbott

More information

ADVANCED HAEMATOLOGY BATTLE OF THE BANDS. Dennis B. DeNicola, DVM, PhD, DACVP IDEXX Laboratories, Inc. Westbrook, Maine, USA BACKGROUND

ADVANCED HAEMATOLOGY BATTLE OF THE BANDS. Dennis B. DeNicola, DVM, PhD, DACVP IDEXX Laboratories, Inc. Westbrook, Maine, USA BACKGROUND ADVANCED HAEMATOLOGY BATTLE OF THE BANDS Dennis B. DeNicola, DVM, PhD, DACVP IDEXX Laboratories, Inc. Westbrook, Maine, USA BACKGROUND The identification of immature neutrophils (bands, metamyelocytes,

More information

Bacterial pneumonia with associated pleural empyema pleural effusion

Bacterial pneumonia with associated pleural empyema pleural effusion EMPYEMA Synonyms : - Parapneumonic effusion - Empyema thoracis - Bacterial pneumonia - Pleural empyema, pleural effusion - Lung abscess - Complicated parapneumonic effusions (CPE) 1 Bacterial pneumonia

More information

Diagnostic Approach to Pleural Effusion

Diagnostic Approach to Pleural Effusion Diagnostic Approach to Pleural Effusion Objectives Define the leading causes of pleural effusion Classify the type of effusion Identify procedures and tests associated with diagnosis 2 Agenda Basic anatomy

More information

Dr. A.Torossian, M.D., Ph. D. Department of Respiratory Diseases

Dr. A.Torossian, M.D., Ph. D. Department of Respiratory Diseases Pleural effusions Dr. A.Torossian, M.D., Ph. D. Department of Respiratory Diseases A pleural effusion is an abnormal collection of fluid in the pleural space resulting from excess fluid production or decreased

More information

Full Blood Count analysis Is a 3 part-diff good enough? Dr Marion Münster, Sysmex South Africa

Full Blood Count analysis Is a 3 part-diff good enough? Dr Marion Münster, Sysmex South Africa Full Blood Count analysis Is a 3 part-diff good enough? Dr Marion Münster, Sysmex South Africa The Role of the FBC in clinical decision making History Examination Investigations Decision 70% FBC Laboratory

More information

Sysmex Journal International Vol.26 No.1 (2016)

Sysmex Journal International Vol.26 No.1 (2016) Sysmex Journal International Vol.26 No.1 (216) Performance Evaluation of the XN-55 Automated Hematology Analyzer Body Fluid Mode Considerations for Operational Conditions for Cell Counting with Cerebrospinal

More information

DIAGNOSTIC EVALUATION OF BLOODY PLEURAL EFFUSION

DIAGNOSTIC EVALUATION OF BLOODY PLEURAL EFFUSION DIAGNOSTIC EVALUATION OF BLOODY PLEURAL EFFUSION Mamatha S, Manish Kumar Singh, Pravati Dutta, Rekha Manjhi, Sudarsan Pothal,Amit Kumar Jha, Nilam Nigam, Sanjay Kumar Nigam 1. Senior Resident, Department

More information

Vascular endothelial growth factor levels in post-cabg pleural effusions are associated with pleural inflammation and permeability

Vascular endothelial growth factor levels in post-cabg pleural effusions are associated with pleural inflammation and permeability Respiratory Medicine (2007) 101, 223 229 Vascular endothelial growth factor levels in post-cabg pleural effusions are associated with pleural inflammation and permeability Ioannis Kalomenidis a,, Georgios

More information

PointCare NOW TM Technical Note

PointCare NOW TM Technical Note PointCare NOW TM Technical Note Introduction to our Technology And Summary of Evaluation and Performance data 1 of 19 Introduction The PointCare NOW is a portable, and very fast, diagnostic instrument

More information

Changes of hematological references depends on storage period and temperature conditions in rats and dogs

Changes of hematological references depends on storage period and temperature conditions in rats and dogs ISSN 1738-6055 (Print) ISSN 2233-7660 (Online) Lab Anim Res 2016: 32(4), 241-248 https://doi.org/10.5625/lar.2016.32.4.241 Changes of hematological references depends on storage period and temperature

More information

Pseudobasophilia in Pediatric Age Group

Pseudobasophilia in Pediatric Age Group Original Article DOI: 10.17354/ijss/2015/259 Pseudobasophilia in Pediatric Age Group Femela Muniraj 1, Vijay Amritraj 2 1 Assistant Professor, Department of Pathology, Chettinad Hospital & Research Institute,

More information

Combined efficacy of pleural fluid lymphocyte neutrophil ratio and pleural fluid adenosine deaminase for the diagnosis of tubercular pleural effusion

Combined efficacy of pleural fluid lymphocyte neutrophil ratio and pleural fluid adenosine deaminase for the diagnosis of tubercular pleural effusion Original article: Combined efficacy of pleural fluid lymphocyte neutrophil ratio and pleural fluid adenosine deaminase for the diagnosis of tubercular pleural effusion Kavita S Kore, Guruprasad Antin,

More information

Blood DLC, Retic count, PCV, Hb and ESR. Dr. Tamara Alqudah

Blood DLC, Retic count, PCV, Hb and ESR. Dr. Tamara Alqudah Blood DLC, Retic count, PCV, Hb and ESR Dr. Tamara Alqudah Differential Leukocyte Count (DLC) There are 5 main types of WBCs: 1. Neutrophils: 40-80% 2. Eosinophils: 1-6 % 3. Basophils: < 1-2% 4. Lymphocytes:

More information

Collect and label sample according to standard protocols. Gently invert tube 8-10 times immediately after draw. DO NOT SHAKE. Do not centrifuge.

Collect and label sample according to standard protocols. Gently invert tube 8-10 times immediately after draw. DO NOT SHAKE. Do not centrifuge. Complete Blood Count CPT Code: CBC with Differential: 85025 CBC without Differential: 85027 Order Code: CBC with Differential: C915 Includes: White blood cell, Red blood cell, Hematocrit, Hemoglobin, MCV,

More information

Analytic Performance of the iq200 Automated Urine Microscopy Analyzer and Comparison With Manual Counts Using Fuchs-Rosenthal Cell Chambers

Analytic Performance of the iq200 Automated Urine Microscopy Analyzer and Comparison With Manual Counts Using Fuchs-Rosenthal Cell Chambers Clinical Chemistry / PERFORMANCE OF THE IQ2 URINALYSIS SYSTEM Analytic Performance of the iq2 Automated Urine Microscopy Analyzer and Comparison With Manual Counts Using Fuchs-Rosenthal Cell Chambers David

More information

Autoanalyzer Generated Spurious Basophilia in Adolescents and Adults

Autoanalyzer Generated Spurious Basophilia in Adolescents and Adults Original Article DOI: 10.17354/ijss/2015/294 Autoanalyzer Generated Spurious Basophilia in Adolescents and Adults Femela Muniraj 1, Vijay Amritraj 2, Govindaraju Soundararajan 3 1 Assistant Professor,

More information

Pleural effusion occurs in up to 89% of patients

Pleural effusion occurs in up to 89% of patients Symptomatic Persistent Post-Coronary Artery Bypass Graft Pleural Effusions Requiring Operative Treatment* Clinical and Histologic Features Y. C. Gary Lee, MBChB; Marcelo A. C. Vaz, MD; Kim A. Ely, MD;

More information

CELL-DYN 3700 Strength in Technology, Proven Reliability

CELL-DYN 3700 Strength in Technology, Proven Reliability CELL-DYN 3700 Strength in Technology, Proven Reliability Optical WBC Technology Patented MAPSS Differential Multiple Technologies CELL-DYN 3700 Multiple Technologies One Superior Result Multiple Technologies

More information

Cholesterol Crystals Causing Falsely Elevated Automated Cell Count

Cholesterol Crystals Causing Falsely Elevated Automated Cell Count Hematopathology / CHOLESTEROL CRYSTALS INFLUENCE CELL COUNT Cholesterol Crystals Causing Falsely Elevated Automated Cell Count Peter U.F. Shen, MD, 1 and Judy L. Blair, MD 2 Key Words: Cholesterol crystal;

More information

Scoring System for Detecting Spurious Hemolysis in Anticoagulated Blood Specimens

Scoring System for Detecting Spurious Hemolysis in Anticoagulated Blood Specimens Original Article Laboratory Informatics Ann Lab Med 2015;35:341-347 http://dx.doi.org/10.3343/alm.2015.35.3.341 ISSN 2234-3806 eissn 2234-3814 Scoring System for Detecting Spurious Hemolysis in Anticoagulated

More information

Validation of Reagent Strips, Comparing with Automated and Manual Cell Counts for the Diagnosis of Spontaneous Bacterial Peritonitis ABSTRACT

Validation of Reagent Strips, Comparing with Automated and Manual Cell Counts for the Diagnosis of Spontaneous Bacterial Peritonitis ABSTRACT Original Article 91 Validation of Reagent Strips, Comparing with Automated and Manual Cell Counts for the Diagnosis of Spontaneous Bacterial Peritonitis Limmathurotsakul D 1 Bhokaisawan N 2 Thaimai P 1

More information

BACKGROUND. Absolute neutrophil counts (ANCs) and absolute phagocyte counts

BACKGROUND. Absolute neutrophil counts (ANCs) and absolute phagocyte counts 2681 Utility of Automated Counting to Determine Absolute Neutrophil Counts and Absolute Phagocyte Counts for Pediatric Cancer Treatment Protocols Nobuko Hijiya, M.D. 1,2 Mihaela Onciu, M.D. 3 Scott C.

More information

BODY FLUID ANALYSIS. Synovial Fluid. Synovial Fluid Classification. CLS 426 Urinalysis and Body Fluid Analysis Body Fluid Lecture Session 1

BODY FLUID ANALYSIS. Synovial Fluid. Synovial Fluid Classification. CLS 426 Urinalysis and Body Fluid Analysis Body Fluid Lecture Session 1 BODY FLUID ANALYSIS Synovial Fluid Serous fluids the 3 P s Peritoneal Pleural Pericardial Cerebrospinal Fluid Karen Keller, MT(ASCP), SH Synovial Fluid Lubricant and sole nutrient source of joint. Normal

More information

Incorporating Differentials Into Every Complete Blood Count. Paige Flowers, LVT Dogwood Veterinary Internal Medicine

Incorporating Differentials Into Every Complete Blood Count. Paige Flowers, LVT Dogwood Veterinary Internal Medicine Incorporating Differentials Into Every Complete Blood Count Paige Flowers, LVT Dogwood Veterinary Internal Medicine Complete Blood Count Diagnostic performed to evaluate the quantity and morphology of

More information

Introduction. 23 rd Annual Seminar in Pathology. FLUIDS, Part 1. Pittsburgh, PA Gladwyn Leiman UVMMC, VT

Introduction. 23 rd Annual Seminar in Pathology. FLUIDS, Part 1. Pittsburgh, PA Gladwyn Leiman UVMMC, VT 23 rd Annual Seminar in Pathology Pittsburgh, PA Gladwyn Leiman UVMMC, VT FLUIDS, Part 1 "Blue walls", Claudia Hansen, 2009 Introduction o Challenging to everyone o Almost any benign or malignant process

More information

Getting Beyond the Flags: Quantitative assessment of immature granulocyte (IG) populations may improve the assessment of sepsis and inflammation.

Getting Beyond the Flags: Quantitative assessment of immature granulocyte (IG) populations may improve the assessment of sepsis and inflammation. Getting Beyond the Flags: Quantitative assessment of immature granulocyte (IG) populations may improve the assessment of sepsis and inflammation. Sysmex America White Paper One Nelson C. White Parkway,

More information

HumaCount 5D. Outperforming 5-part Hematology System. CoreLab DX. Hematology

HumaCount 5D. Outperforming 5-part Hematology System. CoreLab DX. Hematology HumaCount 5D Outperforming 5-part Hematology System Direct Capillary Process by OptimalCount Technology Distinct 5-part Differentiation Definite Immature Cell Count (LIC, ALY) CoreLab DX Hematology 5-part

More information

Sysmex Educational Enhancement & Development

Sysmex Educational Enhancement & Development Sysmex Educational Enhancement & Development SEED-Africa Newsletter No 10 2011 Introducing automated body fluid analysis into the haematology laboratory Automated Body Fluid Analysis The purpose of this

More information

#2 - Hematology I Blood Typing

#2 - Hematology I Blood Typing #2 - Blood Typing Objectives: Learn the theory behind blood typing Be able to perform simulated blood typing and analysis Understand the theory behind blood transfusions (donors and recipients) Observe

More information

E valuation of the patient with a pleural effusion is

E valuation of the patient with a pleural effusion is The Diagnostic Value of Pleural Fluid ph* James T. Good, Jr., M.D.; David A. Taryle, M.D.; Robert M. Maulitz, M.D.; Robin L. Kaplan, M.D.; and Steven A. Sahn, M.D., F.C.C.P. One hundred eighty-three patients

More information

Eosinophilic Pleural Effusion as the First Presentation of Angioimmunoblastic T Cell Lymphoma

Eosinophilic Pleural Effusion as the First Presentation of Angioimmunoblastic T Cell Lymphoma CASE REPORT Eosinophilic Pleural Effusion as the First Presentation of Angioimmunoblastic T Cell Lymphoma Chia-Jung Chang, 1 Jen-Hsun Cheng, 1 Ming-Shian Lin, 1 Yuan-Chang Dai, 2 Tzuen-Ren Hsiue 3 * Eosinophilic

More information

The distinction between transudates and exudates

The distinction between transudates and exudates Journal of Biomedical Science (2005) 12:985 990 985 DOI 10.1007/s11373-005-9014-1 The distinction between transudates and exudates Ugur Gonlugur 1, * & Tanseli Efeoglu Gonlugur 2 1 Department of Chest

More information

Comparison between body fluid mode of Sysmex XN-9000 and optical microscopy for the counting of cells in ascitic fluid

Comparison between body fluid mode of Sysmex XN-9000 and optical microscopy for the counting of cells in ascitic fluid Original Article Page 1 of 5 Comparison between body fluid mode of Sysmex XN-9000 and optical microscopy for the counting of cells in ascitic fluid Vincenzo Roccaforte 1,2,3, Emanuela Zavaroni 1, Rosalba

More information

Evaluation of the Diagnostic Performance of the Sysmex XT-2000i Automated Hematology Analyzer in the Detection of Immature Granulocytes

Evaluation of the Diagnostic Performance of the Sysmex XT-2000i Automated Hematology Analyzer in the Detection of Immature Granulocytes Evaluation of the Diagnostic Performance of the Sysmex XT-2000i Automated Hematology Analyzer in the Detection of Immature Granulocytes A. M. CENCI *1, M. MACONI *2, and B. CASOLARI *1 *1 Laboratory of

More information

CAROL BRIGGS, DONNA GRANT, SAMUEL J. MACHIN INTRODUCTION. Department of Haematology, University College London Hospital, London, United Kingdom

CAROL BRIGGS, DONNA GRANT, SAMUEL J. MACHIN INTRODUCTION. Department of Haematology, University College London Hospital, London, United Kingdom ISLH Laboratory Hematology 7:75-80 2001 Carden Jennings Publishing Co., Ltd. Official Publication Comparison of the Automated Reticulocyte Counts and Immature Reticulocyte Fraction Measurements Obtained

More information

Comparison of manual and automated cell counts in EDTA preserved synovial fluids. Storage has little influence on the results

Comparison of manual and automated cell counts in EDTA preserved synovial fluids. Storage has little influence on the results 622 Annals of the Rheumatic Diseases 1997;56:622 626 CONCISE REPORTS Comparison of manual and automated cell counts in EDTA preserved synovial fluids. Storage has little influence on the results María

More information

The Role of Fiberoptic bronchoscopy in Evaluating The causes of Undiagnosed Pleural Effusion

The Role of Fiberoptic bronchoscopy in Evaluating The causes of Undiagnosed Pleural Effusion IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-083, p-issn: 2279-0861.Volume 16, Issue 1 Ver. VI (January. 2017), PP 80-84 www.iosrjournals.org The Role of Fiberoptic bronchoscopy

More information

Sue Jung Kim, MD, MS; Yoonjung Kim, MD; Saeam Shin, MD; Jaewoo Song, MD, MS; Jong Rak Choi, MD, PhD

Sue Jung Kim, MD, MS; Yoonjung Kim, MD; Saeam Shin, MD; Jaewoo Song, MD, MS; Jong Rak Choi, MD, PhD Comparison Study of the Rates of Manual Peripheral Blood Smear Review From 3 Automated Hematology Analyzers, Unicel DxH 800, ADVIA 2120i, and XE 2100, Using International Consensus Group Guidelines Sue

More information

Atypical Pleural Fluid Profiles in Tuberculous Pleural Effusion: Sequential Changes Compared with Parapneumonic and Malignant Pleural Effusions

Atypical Pleural Fluid Profiles in Tuberculous Pleural Effusion: Sequential Changes Compared with Parapneumonic and Malignant Pleural Effusions ORIGINAL ARTICLE Atypical Pleural Fluid Profiles in Tuberculous Pleural Effusion: Sequential Changes Compared with Parapneumonic and Malignant Pleural Effusions Chang Ho Kim, So Yeon Lee, Yong Dae Lee,

More information

Guide to the 1-3 Minute Blood Film Microscopic Review: Why and How?

Guide to the 1-3 Minute Blood Film Microscopic Review: Why and How? Guide to the 1-3 Minute Blood Film Microscopic Review: Why and How? Dennis B. DeNicola, DVM, PhD, DACVP Chief Veterinary Educator IDEXX Laboratories, Inc. Westbrook, ME USA Adjunct Professor of Veterinary

More information

Pleural fluid analysis

Pleural fluid analysis Pleural fluid analysis Dr Akash Verma Senior Consultant- Department of Respiratory and Critical Care Medicine Tan Tock Seng Hospital, Singapore 308433 Adj A/Professor- Lee Kong Chian School of Medicine

More information

International Journal of Health Sciences and Research ISSN:

International Journal of Health Sciences and Research   ISSN: International Journal of Health Sciences and Research www.ijhsr.org ISSN: 2249-9571 Original Research Article Utility of Modified Cell Block Technique in Cases of Pleural Effusion Suspected of Malignancy

More information

Comparative Evaluation of Two Flowcytometric Analysers as Diagnostic Tools for the Automated Detection of Malaria

Comparative Evaluation of Two Flowcytometric Analysers as Diagnostic Tools for the Automated Detection of Malaria 82 Available online at www.annclinlabsci.org Comparative Evaluation of Two Flowcytometric Analysers as Diagnostic Tools for the Automated Detection of Malaria S. Mohapatra 1, J. C. Samantaray 1, S. Arulselvi

More information

CELL-DYN Strength in Technology, Proven Reliability. Optical WBC Technology. Patented M.A.P.S.S. Differential. Multiple Technologies

CELL-DYN Strength in Technology, Proven Reliability. Optical WBC Technology. Patented M.A.P.S.S. Differential. Multiple Technologies CELL-DYN 3700 Strength in Technology, Proven Reliability Optical WBC Technology Patented M.A.P.S.S. Differential Multiple Technologies CELL-DYN 3700 Multiple Technologies One Superior Result Multiple Technologies

More information

CLINICAL PRACTICE. Clinical Practice

CLINICAL PRACTICE. Clinical Practice Clinical Practice This Journal feature begins with a case vignette highlighting a common clinical problem. Evidence supporting various strategies is then presented, followed by a review of formal guidelines,

More information

Clinical use of flow cytometry

Clinical use of flow cytometry Clinical use of flow cytometry Diagnosis of leukemia Combined use of intracellular staining and a cell surface marker Detection of stem cells CD34+ stem cells Monitoring of stem cell count following

More information

Screening for Urinary Tract Infection with the Sysmex UF-1000i Urine Flow Cytometer

Screening for Urinary Tract Infection with the Sysmex UF-1000i Urine Flow Cytometer JOURNAL OF CLINICAL MICROBIOLOGY, Mar. 2011, p. 1025 1029 Vol. 49, No. 3 0095-1137/11/$12.00 doi:10.1128/jcm.01669-10 Copyright 2011, American Society for Microbiology. All Rights Reserved. Screening for

More information

Refrigerated Storage Improves the Stability of the Complete Blood Cell Count and Automated Differential

Refrigerated Storage Improves the Stability of the Complete Blood Cell Count and Automated Differential H e m a t o p a t h o l o g y / REFRIGERATION IMPROVES CBC COUNT STABILITY Refrigerated Storage Improves the Stability of the Complete Blood Cell Count and Automated Differential Brent L. Wood, MD, PhD,

More information

Optimization of Criteria for Verification of Automated Platelet Counts Generated by the Sysmex XE-2100 Hematology Analyzer

Optimization of Criteria for Verification of Automated Platelet Counts Generated by the Sysmex XE-2100 Hematology Analyzer Optimization of Criteria for Verification of Automated Platelet Counts Generated by the Sysmex XE-2100 Hematology Analyzer Science Gene Gulati, PhD, Sean Cote, DO, Eric Behling, MD, William Kocher, MD

More information

Effective Date: SPECIMEN COLLECTION FOR CULTURE OF BACTERIAL PATHOGENS QUICK REFERENCE

Effective Date: SPECIMEN COLLECTION FOR CULTURE OF BACTERIAL PATHOGENS QUICK REFERENCE 1 of 9 Policy #: Subject: 611 (PLH-611-06) Effective Date: 9/30/2004 Reviewed Date: 8/1/2016 SPECIMEN COLLECTION FOR CULTURE OF BACTERIAL PATHOGENS QUICK REFERENCE Approved by: Laboratory Director, Jerry

More information

XN-SERIES. XN Technology and Case Studies

XN-SERIES. XN Technology and Case Studies XN Technology and Case Studies Karen Hoffman MT(ASCP) Clinical Applications Specialist OBJECTIVES Explain how scattergrams and histogram pictures can provide great insight into abnormal hematology samples

More information

Hematology Revision. By Dr.AboRashad . Mob

Hematology Revision. By Dr.AboRashad  . Mob 1 1- Hb A2 is consisting of: a) 3 ά chains and 2 γ chains b) 2 ά chains and 2 β chains c) 2 ά chains and 2 δ chains** d) 2 ά chains and 3 δ chains e) 3 ά chains and 2 δ chains 2- The main (most) Hb found

More information

A. SAP is the D-Lab's name for a specific set of serum biochemical tests.

A. SAP is the D-Lab's name for a specific set of serum biochemical tests. Understanding CBC, SAP, UA/Laura J. Steadman, DVM I. CBC - Complete Blood Count A. Three major types of cells are counted 1. Red Blood Cells 2. White Blood Cells 3. Platelets B. Cells are counted at the

More information

Cerebrospinal fluid - role

Cerebrospinal fluid - role Cerebrospinal fluid Cerebrospinal fluid CSF is a mixture of fluid generated locally in the brain and filtered serum Total volume 150 ml (the fluid that fills the cerebral ventricles, subarachnoid space

More information

Performance Evaluation of the CellaVision DM96 System WBC Differentials by Automated Digital Image Analysis Supported by an Artificial Neural Network

Performance Evaluation of the CellaVision DM96 System WBC Differentials by Automated Digital Image Analysis Supported by an Artificial Neural Network Hematopathology / DIGITAL IMAGE ANALYSIS IN HEMATOLOGY Performance Evaluation of the CellaVision DM96 System WBC Differentials by Automated Digital Image Analysis Supported by an Artificial Neural Network

More information

APPROACH TO PLEURAL EFFUSIONS. Raed Alalawi, MD, FCCP

APPROACH TO PLEURAL EFFUSIONS. Raed Alalawi, MD, FCCP APPROACH TO PLEURAL EFFUSIONS Raed Alalawi, MD, FCCP CASE 65-year-old woman with H/O breast cancer presented with a 1 week H/O progressively worsening exersional dyspnea. Physical exam: Diminished breath

More information

8.2 Principles of Quantitative Hematologic Determinations (1)

8.2 Principles of Quantitative Hematologic Determinations (1) 3 8. FIELD CENTER HEMATOLOGY SERVICES 8.1 Clinical Significance Quantitation of the formed elements of the blood (erythrocytes -RBCs, leukocytes - WBCs, and platelets) is important in the ARIC study primarily

More information

Vision Hema. Additional modules

Vision Hema. Additional modules Vision Hema Additional modules Vision Hema RTC Digital morphology of reticulocytes Innovative solution for the study of reticulocytes Reticulocytes Reticulocytes young erythrocytes that appear in the bone

More information

Incidence and aetiology of eosinophilic pleural effusion

Incidence and aetiology of eosinophilic pleural effusion Eur Respir J 2009; 34: 1111 1117 DOI: 10.1183/09031936.00197708 CopyrightßERS Journals Ltd 2009 Incidence and aetiology of eosinophilic pleural effusion R. Krenke*, J. Nasilowski*, P. Korczynski*, K. Gorska*,

More information

Changes in Hematologic Parameters Induced by Thermal Treatment of Human Blood

Changes in Hematologic Parameters Induced by Thermal Treatment of Human Blood Annals of Clinical & Laboratory Science, vol. 32, no. 4, 2002 393 Changes in Hematologic Parameters Induced by Thermal Treatment of Human Blood Jong Weon Choi and Soo Hwan Pai Department of Clinical Pathology,

More information

Diagnostic Approach to Pleural Effusion

Diagnostic Approach to Pleural Effusion Original Article GCSMC J Med Sci Vol (IV) No (I) January-June 2015 Diagnostic Approach to Pleural Effusion Rushi Patel*, Viral Shah*, Deepali Kamdar** Abstract : Aim : Normally the pleural cavities contain

More information

Pleural fluid. creatinine - urinothorax haematocrit -haemothorax bilirubin gut perforation. Fluid samples 1st Plain Universal ( cell count)

Pleural fluid. creatinine - urinothorax haematocrit -haemothorax bilirubin gut perforation. Fluid samples 1st Plain Universal ( cell count) Examination Purpose of test Sample 17725 Fluid Profile (appearance, culture, WBC differential, ph, total protein, glucose, amylase, triglyceride, albumin, HDL) Peritoneal/ascitic and pleural fluid are

More information

Malignant Effusions. Anantham Devanand Respiratory and Critical Care Medicine Singapore General Hospital

Malignant Effusions. Anantham Devanand Respiratory and Critical Care Medicine Singapore General Hospital Malignant Effusions Anantham Devanand Respiratory and Critical Care Medicine Singapore General Hospital Malignant Effusions Definition: Presence of malignant cells in the pleural space 75% are caused by

More information

Urine Sediment Photomicrographs/Photographs

Urine Sediment Photomicrographs/Photographs Urine Sediment Photomicrographs/Photographs Case History CMP-17 This urine sample is from a 48-year-old male with a 30-year history of diabetes mellitus and new onset renal failure. Laboratory data include:

More information

Tunn Ren Tay * and Augustine Tee

Tunn Ren Tay * and Augustine Tee Tay and Tee BMC Infectious Diseases 2013, 13:546 RESEARCH ARTICLE Open Access Factors affecting pleural fluid adenosine deaminase level and the implication on the diagnosis of tuberculous pleural effusion:

More information

Blutbild 2012: Automatisiert oder manuell? Georg Stüssi Servizio di Ematologia Istituto Oncologico della Svizzera Italiana

Blutbild 2012: Automatisiert oder manuell? Georg Stüssi Servizio di Ematologia Istituto Oncologico della Svizzera Italiana Blutbild 2012: Automatisiert oder manuell? Georg Stüssi Servizio di Ematologia Istituto Oncologico della Svizzera Italiana IS THERE STILL A ROLE FOR THE MANUAL BLOOD COUNT? Indication for examination

More information

Forum for Collaborative HIV Research External Validation of CD4 and Viral Load Assays Paris, France June 29, 2007

Forum for Collaborative HIV Research External Validation of CD4 and Viral Load Assays Paris, France June 29, 2007 Forum for Collaborative HIV Research External Validation of CD4 and Viral Load Assays Paris, France June 29, 2007 Thomas J. Spira, M.D. International Laboratory Branch Global AIDS Program Centers for Disease

More information

Med Chem 535P ~ Diagnostic Medicinal Chemistry. General Comments

Med Chem 535P ~ Diagnostic Medicinal Chemistry. General Comments Med Chem 535P ~ Diagnostic Medicinal Chemistry General Comments Most blood chemistry and serology assays are performed automatically. Larger clinical laboratories often use sophisticated analyzers that

More information

ROLE OF FIBREOPTIC BRONCHOSCOPY IN EVALUATION OF PLEURAL EFFUSION CASES

ROLE OF FIBREOPTIC BRONCHOSCOPY IN EVALUATION OF PLEURAL EFFUSION CASES ROLE OF FIBREOPTIC BRONCHOSCOPY IN EVALUATION OF PLEURAL EFFUSION CASES Somnath Dash, Sushanta Kumar Mishra, G. Srinivas, K. V. Ramana Rao, N. Durga Prasad 1. Associate Professor. Department of Pulmonary

More information

Precision and Accuracy of the Leukocyte Differential on the Sysmex XE-2100

Precision and Accuracy of the Leukocyte Differential on the Sysmex XE-2100 Precision and Accuracy of the Leukocyte Differential on the Sysmex XE-2100 R. HERKLOTZ and A. R. HUBER Zentrum für Labormedizin, Kantonsspital Aarau, 5001 Aarau, Switzerland. The automated leukocyte(wbc)

More information

Pulmonary Morning Report. Ashley Schmehl D.O. PGY-3 January,

Pulmonary Morning Report. Ashley Schmehl D.O. PGY-3 January, Pulmonary Morning Report Ashley Schmehl D.O. PGY-3 January, 8 2015 Pleural Effusion Unilateral versus Bilateral Associated symptoms Transudate versus Exudate Light s Criteria: Pleural protein: Serum protein

More information

First comparative evaluation of leucocyte differential and reticulocyte count between Abbott Cell -DYN 3700 and Beckman-Coulter Gen S

First comparative evaluation of leucocyte differential and reticulocyte count between Abbott Cell -DYN 3700 and Beckman-Coulter Gen S 111 Riv Med Lab - JLM, Vol. 4, N. 2, 2003 First comparative evaluation of leucocyte differential and reticulocyte count between Abbott Cell -DYN 3700 and Beckman-Coulter Gen S H. Vandeputte a, D. Darre

More information

Clinical & Laboratory Assessment

Clinical & Laboratory Assessment Clinical & Laboratory Assessment Dr Roger Pool NHLS & University of Pretoria Clinical Assessment (History) Anaemia ( haemoglobin) Dyspnoea (shortness of breath) Tiredness Angina Headache Clinical Assessment

More information

Pulmonary embolism is a common disorder associated. Biochemical and Cytologic Characteristics of Pleural Effusions Secondary to Pulmonary Embolism*

Pulmonary embolism is a common disorder associated. Biochemical and Cytologic Characteristics of Pleural Effusions Secondary to Pulmonary Embolism* Biochemical and Cytologic Characteristics of Pleural Effusions Secondary to Pulmonary Embolism* Santiago Romero Candeira, MD; Luis Hernández Blasco, MD; Maria J. Soler, MD; Alejandro Muñoz, MD; and Ignacio

More information

LAB TIME/DATE. 1. most numerous leukocyte. 3. also called an erythrocyte; anucleate formed element. 6. ancestral cell of platelets

LAB TIME/DATE. 1. most numerous leukocyte. 3. also called an erythrocyte; anucleate formed element. 6. ancestral cell of platelets ighapmlre29apg245_250 5/12/04 2:46 PM Page 245 impos03 302:bjighapmL:ighapmLrevshts:layouts: NAME Blood LAB TIME/DATE REVIEW SHEET exercise 29A Composition of Blood 1. What is the blood volume of an average-size

More information

Evaluation Report: Eurolyser CRP test (ST0100 and ST0102) on. CUBE analyser (CA0100)

Evaluation Report: Eurolyser CRP test (ST0100 and ST0102) on. CUBE analyser (CA0100) Evaluation Report: Eurolyser CRP test (ST0100 and ST0102) on CUBE analyser (CA0100) Location Location: Eurolyser Diagnostica GmbH Operators: Simone Wieser; Franz Helminger; Michael Gruber Date: July-November

More information

Evaluation of the Abbott Cell-DYN 3500 Hematology Analyzer in a University Hospital

Evaluation of the Abbott Cell-DYN 3500 Hematology Analyzer in a University Hospital HEMATOPATHOLOGY Evaluation of the Abbott Cell-DYN 3500 Hematology Analyzer in a University Hospital JOAN-LLUIS VIVES-CORRONS, MD, ISABEL BESSON, PHD, JOSEP MARIA JOU, MD, AND GABRIELA GUTIERREZ, MB The

More information

JMSCR Volume 03 Issue 05 Page May 2015

JMSCR Volume 03 Issue 05 Page May 2015 www.jmscr.igmpublication.org Impact Factor 3.79 ISSN (e)-2347-176x Time Effect Storage Artifacts of Anticoagulant EDTA on Peripheral Blood Cells Authors Dr. Ramu Thakur 1, Dr.O.P.Moorjani 2 1 Assitant

More information

Investigating the recheck rules for urine analysis in children

Investigating the recheck rules for urine analysis in children Investigating the recheck rules for urine analysis in children Y.M. He*, S.W. Yao*, Y.J. Huang, B.S. Liang and H.Y. Liu Clinical Laboratory, Guangzhou Women and Children s Medical Center, Guangzhou Medical

More information

We noted a problem with the use of the hematology

We noted a problem with the use of the hematology Standard Article J Vet Intern Med 2017;31:1708 1716 Feline Differential Leukocyte Count with ProCyte Dx: Frequency and Severity of a Neutrophil-Lymphocyte Error and How to Avoid It H.W. Tvedten, V. Andersson,

More information

Serous fluids. Dr. Mohamed Saad Daoud

Serous fluids. Dr. Mohamed Saad Daoud Serous fluids 1 Reference Books: Urinanalysis and body fluids (Susan King Strasinger- Marjorie Schaub De Lorenzo) Fifth edition 2 The closed cavities of the body namely, the pleural, pericardial, and peritoneal

More information

Evaluation of VACUETTE Urine CCM Tubes for Urine Strip Testing

Evaluation of VACUETTE Urine CCM Tubes for Urine Strip Testing Evaluation of VACUETTE Urine CCM Tubes for Urine Strip Testing Background The VACUETTE Urine is for the collection, transport and storage of urine samples for urine culture and urinalysis in the laboratory.

More information

Mesothelioma: diagnostic challenges from a pathological perspective. Naseema Vorajee August 2016

Mesothelioma: diagnostic challenges from a pathological perspective. Naseema Vorajee August 2016 Mesothelioma: diagnostic challenges from a pathological perspective Naseema Vorajee August 2016 Naseema.vorajee@nhls.ac.za Pleural diseases (whether neoplastic, reactive or infective) may have similar

More information

Manejo Práctico del Derrame Pleural

Manejo Práctico del Derrame Pleural Manejo Práctico del Derrame Pleural San José, Costa Rica Junio 29, 2017 Rodrigo Cartín Ceba, MD, MSc Consultant, Pulmonary and Critical Care Medicine Associate Professor of Medicine Mayo Clinic 2010 MFMER

More information