EVALUATION OF MIL-STD-883/TEST METHOD FOR BIPOLAR LINEAR CIRCUITS

Size: px
Start display at page:

Download "EVALUATION OF MIL-STD-883/TEST METHOD FOR BIPOLAR LINEAR CIRCUITS"

Transcription

1 EVALUATION OF MIL-STD-883/TEST METHOD 09.6 FOR BIPOLAR LINEAR CIRCUITS Introduction. Ronald Pease, RLP Research, Los Lunas, NM 8703 John Seiler, NAVSEA Crane, IN A true dose rate response was first reported in bipolar linear circuit transistors in 99 [] and in bipolar linear circuits in 994 [2-4]. In these papers it was made clear that the standard test condition in MIL-STD-883 Test Method 09 (TM09 test condition A) did not work for many bipolar linear circuits used in a low dose rate space environment. In addition, the post irradiation annealing test ( rebound test), of TM09.4 required for MOS circuits in a low dose rate environment was not conservative for bipolar linear circuits. At that time the only test that could be recommended was a low dose rate test. In 994 a model of the enhanced low dose rate sensitivity, ELDRS, was proposed that suggested an accelerated test for ELDRS consisting of irradiation at an elevated temperature [5]. Several studies have been conducted to establish the appropriate dose rate and temperature for the elevated temperature irradiation test [6-8] and recommendations were made in 997 for ELDRS tests [9]. These recommendations were incorporated in an ASTM guideline document (F892-98) Standard Guide for Ionizing Radiation (Total Dose) Effects Testing of Semiconductor Devices, which has recently been updated (F892-03). In March of 2003 TM09 was revised to include tests for bipolar linear circuits, TM09.6, consisting of a low dose rate test and an accelerated (elevated temperature irradiation) test. The purpose of this paper is to present data on four circuit types that have shown enhanced low dose rate response, to evaluate the effectiveness of the new test methods in TM09.6. TM09.6 test options. For all linear and mixed-signal circuits that are comprised of bipolar circuit elements and have not been demonstrated to be free of enhanced low dose rate sensitivity (ELDRS), there are three options for total dose testing (TM09.6 paragraph 3.3.), a) test at the agreed to dose rate, b) test at a prescribed low dose rate, or c) test at an elevated temperature. These options are shown in Fig., taken from TM09.6, Figure 2. Option a) is the standard option that allows testing at the mission dose rate or one agreed to by the procurement agency (Condition C). Option b) allows testing at 0 m for specification doses 25 krad or for a total irradiation time of 000 hours if the specification is > 25 krad (Condition D). For Condition D the test level is.5 times the specification level if the dose rate is 0 m and 2.0 times the specification level if the dose rate is > 0 m. Option c) allows testing at an irradiation temperature of 00 C with a dose rate between 0.5 and 5 to the specification dose with a parameter delta design margin of 3.0 (Condition E). For Condition E the test is limited to a specification dose of 50 krad unless it can be demonstrated that the test works above that dose. For the low dose rate tests, Condition D, the design margin or overtest factor is included because of the uncertainty in bounding the maximum enhancement that may occur at lower dose rates. The overtest factors (.5 and 2.0) are safety margins that are educated guesses, since there is not a large data base for dose rates below 0 m. For the elevated temperature tests, Condition E, no overtest factor is included since longer times at elevated temperature may cause recovery of the parts (this is also why the test is limited to 50 krad). Instead, the design margin or

2 2 safety factor is applied to the irradiation induced change in the critical parameters. The factor of 3 is based on data taken on several part types from a 998 study [0]. Determine the need for ELDRS testing See Para. 3.3 Yes No Pass Perform standard test (Para 3.6. Condition A) See Para Test at the agreed to dose rate per Para Condition C Pass Perform low dose rate test per Para Condition D. 25 krad: 0 m, dose=.5 spec 2. >25 krad: 000 hrs, dose=2 spec Pass Perform elevated temperature irradiation per Para Condition E. May be used if spec dose 50 krad (see 3.6.5) , 00 C 3. Parameter delta design margin = 3 Pass Figure. The ELDRS test flow taken from TM09.6, Figure 2. Evaluation test circuits and test conditions. For this evaluation of TM09.6 four circuit types were purchased in quantities of 00 from single date code lots; Texas Instruments LM24 quad op amp, Texas Instruments LM39 quad comparator, ON Semi (Motorola) LM224 quad op amp and ON semi LM239 quad comparator. The LM24 and LM39 are widely used in space systems and previous data on these manufacturer s parts have shown them to be ELDRS []. While widely characterized in recent years, samples from National Semiconductor were not chosen, since their current commercial process is not ELDRS, and their space qualified process is undergoing modification and has not stabilized. Five samples of each type were irradiated under bias. The irradiation bias conditions are shown in Fig. 2. The bias condition for the op amps was a voltage follower with Vcc =+5V, Vee=0V and input voltage of 0.5V for each op amp in the package. For the comparators the supply voltages were the same as for the op amps and the two inputs of each comparator were at 0.5 and V, with two outputs high and two low. The test matrix showing the dose rates, total dose levels, irradiation temperature and test facility is shown in Table.

3 3 0.5V V LM24.0V +5V + LM V K 0.5V Figure 2. Irradiation bias conditions for the LM24/LM224 (left) and LM39/LM239 (right). All electrical measurements were made at room temperature on an Eagle linear test system. While all of the basic specification parameters were measured, the only parameters to change significantly were the input bias currents (Ib+ and Ib-), the offset voltage, Vos, and the offset current, Ios. Measurements were made on all four of the circuits in each package. The test at 2.6 m is used as the baseline low dose rate test to determine if the TM09.6 tests bound the low dose rate response. The specification total dose levels were originally assumed to be 30 and 50 krad for the ON Semi parts and 50 and 00 krad for the Texas Instruments parts, for the purpose of establishing the dose rates for the 000 hour tests. These specifications lead to the dose rates of 6.7, 27.8, and 55.6 m (2X specification dose /000 hours). The high dose rate test (00 ) is used to establish the low dose rate enhancement factors as a function of dose. The elevated temperature irradiation tests were performed using a Thermostream forced air heating unit to bring the temperature of the parts up to 00 C prior to irradiation. The parts were cooled to room temperature for post irradiation electrical characterization. Table. Irradiation test matrix. Dose rate () Dose (krad) Rad Temp ( C) Test facility ,5,0,20,30,50 25 RTI 0.0 5,0,20,30,50,75,00,50 25 RTI ,45,60 (000 hrs) 25 Crane ,75,00 (000 hrs) 25 Crane ,00,200 (000 hrs) 25 Crane 0.5 0,20,30,50,00 00 Crane 5 0,20,30,50,00 00 Crane 00 0,20,30,50,00,200, Crane Test results. Data for the four most sensitive parameters, Ib+, Ib-, Vos and Ios, have been analyzed for the irradiation induced parameter change for each circuit in each package. To illustrate the raw data (not processed according to the TM09.6 design margins) Figs. 3 and 4 show the changes in Ib+ vs. dose for each of the tests listed in Table for the Texas Instruments parts and the ON Semi parts, respectively. The data are presented as the absolute values of the average changes for all circuits in each of the five packages.

4 Del Ib(0.0026) Del Ib(0.0) Del Ib(0.027) Del Ib(0.055) Del Ib(00) Del Ib(ETI-0.5) Del Ib(ETI-5) Del Ib (na) Spec Del Ib (na) 00 Spec 0 Del Ib(0.0026) Del Ib(0.0) Del Ib(0.027) Del Ib(0.055) Del Ib(00) Del Ib(ETI-0.5) Del Ib(ETI-5) Dose (krad) Dose (krad) Figure 3. Absolute value of ave. Del Ib+ vs. dose for all irradiation tests for T.I. parts with LM24 op amp on the left and LM39 comparator on the right Del Ib(0.0026) Del Ib(0.0) Del Ib(0.027) Del Ib(00) Del Ib(ETI-0.5) Del Ib(ETI-5) Del Ib (na) 00 Spec Del Ib(0.0026) Del Ib(0.0) Del Ib(0.027) Del Ib(00) Del Ib(ETI-0.5) Del Ib(ETI-5) Del Ib (na) 00 Spec Dose (krad) Dose (krad) Figure 4. Absolute value of ave. Del Ib+ vs. dose for all irradiation tests for ON Semi parts with LM224 op amp on the left and LM239 comparator on the right. From Fig. 3 we can see that the Texas Instrument parts demonstrate a very large low dose rate enhancement factor and that all low dose rate (LDR) and elevated temperature irradiation (ETI) tests result in significantly more degradation than the high dose rate (HDR) test. On the other hand the ON Semi parts, shown in Fig. 4, only demonstrate ELDRS at relatively low total dose

5 5 levels, less than 20 krad for the LM224 and less than krad for the LM239, since above these levels the HDR test results in more degradation than the 2.6 m test. Since the ON Semi parts are only ELDRS at relatively low dose levels the test method cannot be applied to these parts except at dose levels below about 20 krad. Hence the 000 hour test is not applicable to these parts. In fact the ON Semi parts proved to be a poor choice for this validation test, although previous data on these Motorola parts showed a strong ELDRS behavior. This demonstrates once again the large amount of variation that can be expected lot to lot for many ELDRS parts. The test method was applied on the T.I. parts at 25 krad and 50 krad and on the ON Semi parts at 0 krad and 20 krad. To evaluate the test method, the low dose rate test was applied at 0 m for the ON Semi parts and at 25 krad for the T.I. parts by comparing the average change in parameter at.5x the specification dose to the average change in parameter at the specification dose for the 2.6 m irradiation. For the T. I. parts at 50 k the average change in parameter at 00 krad for the 27.8 mrad was compared to the average change in parameter at 50 krad for the 2.6 m irradiation (000 hour test with design margin of 2). For the ETI tests the two extremes of the dose rate range of 0.5 to 5 were used. The average change in parameters at the specification dose were multiplied by three and compared to the average change in parameter at the specification dose at 2.6 m. The ratio of the parameter change for the LDR and ETI tests per TM09.6 to the average parameter change at 2.6 m was calculated. If this ratio exceeds one then the test is conservative and if the ratio is less than one the test is non-conservative and the TM09.6 test fails. If the degraded parameter did not exceed the pre-irradiation specification limit at the specification dose at 2.6 m, then the test was not applied, since the part would not be considered a failure in a lot acceptance test. In order to illustrate the variation that may occur for the four circuits in a quad package, the average change of the five samples was calculated for each of the four circuits within a package. Fig. 5 shows the results of the application of TM09.6 tests for the T.I. parts for an assumed specification dose of 50 krad. For this dose the LDR test is a 000 hour test at 27.8 m. The LM24 op amp is shown on the left and the LM39 comparator is shown on the right. 6 4 Ratio TM09 test to baseline Blue Del Ib+ Red Del Vos Green Del Ios Ratio TM09 test to baseline 3 2 Blue Del Ib+ Red Del Vos Green Del Ios 0 PASS 27 m 000 hour PASS ETI 5 PASS ETI to show ELDRS 0 27 m 000 hour ETI 5 ETI to show ELDRS Figure 5. Ratio of TM09.6 test to baseline 2.6 m test for T. I. parts for a spec dose of 50 krad, with the LM24 on the left and LM39 on the right.

6 6 The groups of columns show results for the 000 hour LDR test at 27.8 m, the ETI test at 5 and the ETI test at 0.5. Within each group are results for Del Ib+ (blue), Del Vos (red) and Del Ios (green). The four bars in each group are for the four circuits in a package. The notation pass indicates that the part did not fail the parameter at 2.6 m at 50 krad. The data on the right of each figure for 00 illustrates the amount of low dose rate enhancement. There are two cases where the TM09.6 ELDRS tests failed to bound the very low dose rate results. First the 000 hour test did not work for the op amps for Del Ib+. This means that the change at 00 krad and 27.8 m was not as great as the change at 50 krad at 2.6 m. The second case is the ETI test at 5 for Del Ios on the comparator. In this case there was a very large spread in results for the four circuits in the package. While the test worked for two circuits and not the other two it must be considered a failure. Fig. 6 shows the results for the ON Semi parts with the LM224 on the left for a specification dose of 0 krad and the LM239 on the right for a specification dose of 20 krad. In both cases the LDR test is at 0 m. For the op amp the offset parameters did not fail the prerad specification at 2.6 m so the test did not apply. However, for the comparator the offset parameters did exceed the pre-rad spec and the changes for the ETI test at 5, when multiplied by three, were less than the changes at 2.6 mrd/s, hence the test failed. Ratio TM09 test to baseline Blue Del Ib+ Red Del Vos Green Del Ios Ratio TM09 test to baseline Blue Del Ib+ Red Del Vos Green Del Ios pass pass pass 0 0 m ETI 5 ETI to show ELDRS 0 0 m ETI 5 ETI to show ELDRS Figure 6. Ratio of TM09.6 test to baseline 2.6 m test for ON Semi parts with LM224 on the left for a spec dose of 0 krad and the LM239 on the right for a spec dose of 20 krad. The results of the evaluation of the TM09.6 ELDRS tests are summarized for two specification levels for each of the circuit types in Tables 2 and 3. Table 2 shows the results for the T.I. parts at 25 krad and 50 krad and Table 3 shows the results for the ON Semi parts at 0 krad and 20 krad. In Table 2 the comparator is shown at the top and the op amp at the bottom. At 25 krad the LDR test is at 0 m and at 50 krad the LDR test is at 000 hours. The notation in the table is the following: yes means the test worked, i.e. the results were conservative; pass means the parameter passed the pre-rad spec at the specification dose at 2.6 m; no means the test failed for all four circuits in the package and x/4 means that only x of four circuits in the package passed the test. However, as we have stated before, if any of the circuits in the package fail, the test fails. The ETI test at 5 does not work well for offset

7 7 parameters, especially for the comparators. There was one case where the 00 hour test did not work, i.e. for Del Ib+ on the op amp at 50 krad. Table 2. Summary of TM09 validation tests for T. I. parts at 25 and 50 krad. TI comparator LM39 25 krad 50 krad Del Ib Del Ios Del Vos Del Ib Del Ios Del Vos 0 m test Yes Yes Yes 000 hr (50 krad) Yes Yes Yes ETI test at 5 Yes /4 No Yes 3/4 Yes ETI test at 0.5 Yes Yes Yes Yes Yes Yes TI op amp LM24 25 krad 50 krad Del Ib Del Ios Del Vos Del Ib Del Ios Del Vos 0 m test Yes Yes Pass 000 hr (50 krad) No Yes Pass ETI test at 5 Yes Yes Pass 3/4 Yes Pass ETI test at 0.5 Yes Yes Pass Yes Yes Pass Table 3. Summary of TM09 validation tests for ON Semi parts at 0 and 20 krad. ON Semi comparator LM239 0 krad 20 krad Del Ib Del Ios Del Vos Del Ib Del Ios Del Vos 0 m test Yes Yes Yes Yes Yes Yes ETI test at 5 Yes 3/4 3/4 Yes No 2/4 ETI test at 0.5 Yes Yes Yes Yes Yes Yes ON Semi op amp LM224 0 krad 20 krad Del Ib Del Ios Del Vos Del Ib Del Ios Del Vos 0 m test Yes Pass Pass Yes Pass Pass ETI test at 5 Yes Pass Pass Yes Pass Pass ETI test at 0.5 Yes Pass Pass Yes Pass Pass For the ON Semi parts shown in Table 3 the ETI test at 5 did not work for the comparator offset parameters. Conclusions. The latest version of MIL-STD-883/Test Method 09 for total dose, dated March 2003, includes several tests for linear and mixed-signal circuits containing bipolar elements. Four part types, previously shown to demonstrate ELDRS, were selected to evaluate the efficiency of these test options for bounding the space like low dose rate response. The parts from Texas Instruments proved to be a good choice but the parts from ON Semi only demonstrated ELDRS at low doses and were of limited usefulness for evaluating the standard. The criteria used as the baseline for the evaluation is a test at 2.6 m. The results of the evaluations are that the 0 m test and the ETI test at 0.5 worked in all cases investigated. However, the elevated temperature irradiation test at 00 C and 5 did not work for offset parameters, especially for the comparator. These results are consistent with those published in reference 8. While the

8 8 000 hour LDR test was only applied on the Texas Instruments parts, it was found not to be conservative for the op amp Ib+ parameter at 50 krads. Hence this evaluation has shown that in the next revision of TM09 the upper dose rate range for the 00 C test should probably be substantially lowered. Additional testing to evaluate the 000 hour LDR test should be done before any recommended changes to TM09 can be made. Acknowledgements This work was funded by the Defense Threat Reduction Agency Radiation Hardened Microelectronics Program. The authors would like to thank Lew Cohn, Dale Platteter, and Nathan Nowlin for technical discussions. References [] E. W. Enlow, R. L. Pease, W. E. Combs, R. D. Schrimpf and R. N. Nowlin, "Response of Advanced Bipolar Processes to Ionizing Radiation", IEEE Trans. Nuc. Sci. NS-38, No.6, , December 99. [2] S. McClure, R. L. Pease, W. Will and G. Perry, "Dependence of Total Dose Response of Bipolar Linear Microcircuits on Applied Dose Rate", IEEE Trans. Nuc. Sci. NS-4, No.6, , December 994. [3] A. H Johnston, G. M. Swift and B. G. Rax, Total Dose Effects in Conventional Bipolar Transistors and Linear Integrated Circuits, IEEE Trans. Nuc. Sci. NS-4, No.6, , December 994. [4] J. T. Beaucour, T. Carriere, A. Gach, D. Laxague and P. Poirot, Total Dose Effects on Negative Voltage Regulator, IEEE Trans. Nuc. Sci. NS-4, No.6, , December 994. [5] D. M. Fleetwood, S. L. Kosier, R. N. Nowlin, R. D. Schrimpf, R. A. Reber, Jr., M. DeLaus, P. S. Winokur, A. Wei, W. E. Combs and R. L. Pease, "Physical Mechanisms Contributing to Enhanced Bipolar Gain Degradation at Low Dose Rates", IEEE Trans. Nuc. Sci. NS-4, No.6, , December 994. [6] Witczak, S. C., R. D. Schrimpf, K. F. Galloway, D. M. Fleetwood, R. L. Pease, J. M. Puhl, D. M. Schmidt, W. E. Combs, and J. S. Suehle, "Accelerated Tests for Simulating Low Dose Rate Gain Degradation of Lateral and Substrate PNP Bipolar Junction Transistors, IEEE Trans. Nuc. Sci. NS- 43, No.6, , December 996. [7] Pease, R. L. and M. Gehlhausen, "Elevated Temperature Irradiation of Bipolar Linear Microcircuits", IEEE Trans. Nuc. Sci. NS-43, No.6, , December 996. [8] T. Carriere, R. Ecoffet and P. Poirot, Evaluation of Accelerated Total Dose Testing of Linear Bipolar Circuits, IEEE Trans. Nucl. Sci. NS-47, No.6, , December [9] Pease, R. L., L. M. Cohn, D. M. Fleetwood, M. A. Gehlhausen, T. L. Turflinger, D. B. Brown and A. H. Johnston, A Proposed Hardness Assurance Test Methodology for Bipolar Linear Circuits and Devices in a Space Ionizing Radiation Environment, IEEE Trans. Nucl. Sci. NS-44, No.6, , December 997. [0] Pease, R. L., M. Gehlhausen, J. Krieg, J. Titus, T. Turflinger, D. Emily and L. Cohn, Evaluation of Proposed Hardness Assurance Method for Bipolar Linear Circuits with Enhanced Low Dose Rate Sensitivity (ELDRS), IEEE Trans. Nucl. Sci. NS-45, No.6, December 998. [] Pease, R. L., S. McClure, A. H. Johnston, J. Gorelick, T. L. Turflinger, M. Gehlhausen, J. Krieg, T. Carriere, and M. Shaneyfelt, An Updated Compendium of Enhanced Low Dose Rate Sensitive (ELDRS) Bipolar Linear Circuits, 200 IEEE Radiation Effects Data Workshop Record, p. 27.

TOTAL IONIZING DOSE RADIATION TEST REPORT RH3080

TOTAL IONIZING DOSE RADIATION TEST REPORT RH3080 TOTAL IONIZING DOSE RADIATION TEST REPORT RH3080 April 2018 Product: Total ionizing dose level: Source: Dose Rate: Facilities: Radiation Test Report RH3080 High dose rate: 200 krad(si) Low dose rate: 100

More information

CCT radiation Assurance radiation dans un projet : Effets de dose ionisante (TID)

CCT radiation Assurance radiation dans un projet : Effets de dose ionisante (TID) CCT radiation Assurance radiation dans un projet : Effets de dose ionisante (TID) Renaud Mangeret EADS ASTRIUM SAS Toulouse 27 Mars 2006 Page 1 CCT Radiation & composants - 27 Mars 2006 Radiation : why

More information

Silicon Amnesia and Dementia:

Silicon Amnesia and Dementia: Silicon Amnesia and Dementia: Radiation effects in microelectronics Dr. Robert Baumann TI and IEEE Fellow Technology Office Aerospace and Defense Products Robert Baumann Robert Baumann Slide 1/20 Texas

More information

IRUH3301 Voltage Regulator. Enhanced Low Dose Rate Sensitivity Test Report. July 2010

IRUH3301 Voltage Regulator. Enhanced Low Dose Rate Sensitivity Test Report. July 2010 Regulator Enhanced Low Dose Rate Sensitivity Test Report International Rectifier currently does not have a DSCC approved Radiation Hardness Assurance Program for MIL-PRF-38534. Table of Contents Introduction..

More information

Total Ionizing Dose Test Report. No. 16T-RT3PE3000L-CG896-QMLPK

Total Ionizing Dose Test Report. No. 16T-RT3PE3000L-CG896-QMLPK Total Ionizing Dose Test Report No. 16T-RT3PE3000L-CG896-QMLPK December 1, 2016 Table of Contents I. Summary Table... 3 II. Total Ionizing Dose (TID) Testing... 3 A. Device-Under-Test (DUT) and Irradiation

More information

TOTAL IONIZING DOSE TEST REPORT

TOTAL IONIZING DOSE TEST REPORT TOTAL IONIZING DOSE TEST REPORT No. 07T-RTAX2000S-D2S8N5 Sept. 5, 2007 J.J. Wang (650) 318-4576 jih-jong.wang@actel.com I. SUMMARY TABLE Parameter Tolerance 1. Functionality Passed 300 krad(sio 2 ) 2.

More information

Total Ionizing Dose Test Report. No. 18T-RT4G150-LG1657-K04J0

Total Ionizing Dose Test Report. No. 18T-RT4G150-LG1657-K04J0 Total Ionizing Dose Test Report No. 18T-RT4G150-LG1657-K04J0 March 27, 2018 Table of Contents I. Summary Table...3 II. Total Ionizing Dose (TID) Testing...3 A. Device-Under-Test (DUT) and Irradiation Parameters...3

More information

RDHA710FR10A1NK. Neutron and Total Ionizing Dose Test Report. October 2009

RDHA710FR10A1NK. Neutron and Total Ionizing Dose Test Report. October 2009 Neutron and Total Ionizing Dose Test Report International Rectifier currently does not have a DSCC approved Radiation Hardness Assurance Program for MIL-PRF-38534. 205 Crawford St, Leominster, Ma 01453

More information

TOTAL IONIZING DOSE TEST REPORT

TOTAL IONIZING DOSE TEST REPORT October 10, 2000 TOTAL IONIZING DOSE TEST REPORT No. 00T-RT14100-UCL082 J. J. Wang (408)522-4576 jih-jong.wang@actel.com I. SUMMARY TABLE Parameters Tolerance 1. Gross Functional > 20krad(Si), exact number

More information

DOWNLOAD OR READ : TAKE CHARGE OF BIPOLAR DISORDER PDF EBOOK EPUB MOBI

DOWNLOAD OR READ : TAKE CHARGE OF BIPOLAR DISORDER PDF EBOOK EPUB MOBI DOWNLOAD OR READ : TAKE CHARGE OF BIPOLAR DISORDER PDF EBOOK EPUB MOBI Page 1 Page 2 take charge of bipolar disorder take charge of bipolar pdf take charge of bipolar disorder A bipolar junction transistor

More information

NEW METHODS FOR SENSITIVITY TESTS OF EXPLOSIVE DEVICES

NEW METHODS FOR SENSITIVITY TESTS OF EXPLOSIVE DEVICES NEW METHODS FOR SENSITIVITY TESTS OF EXPLOSIVE DEVICES Amit Teller 1, David M. Steinberg 2, Lina Teper 1, Rotem Rozenblum 2, Liran Mendel 2, and Mordechai Jaeger 2 1 RAFAEL, POB 2250, Haifa, 3102102, Israel

More information

Application of Op-amp Fixators in Analog Circuits

Application of Op-amp Fixators in Analog Circuits Application of Op-amp Fixators in Analog Circuits R. Rohith Krishnan #1, S. Krishnakumar *2 # Department of Electronics, S.T.A.S, M.G. University Regional Centre Edappally, Kochi, Kerala, India 1 rohithpunnoor@gmail.com

More information

Verilog-AMS-PAM: Verilog-AMS integrated with Parasitic-Aware Metamodels for Ultra-Fast and Layout-Accurate Mixed- Signal Design Exploration

Verilog-AMS-PAM: Verilog-AMS integrated with Parasitic-Aware Metamodels for Ultra-Fast and Layout-Accurate Mixed- Signal Design Exploration Verilog-AMS-PAM: Verilog-AMS integrated with Parasitic-Aware Metamodels for Ultra-Fast and Layout-Accurate Mixed- Signal Design Exploration G. Zheng 1, S. P. Mohanty 2, E. Kougianos 3, and O. Garitselov

More information

Texas A&M University Electrical Engineering Department. ELEN 665 RF Communication Circuits Laboratory Fall 2010

Texas A&M University Electrical Engineering Department. ELEN 665 RF Communication Circuits Laboratory Fall 2010 Texas A&M University Electrical Engineering Department ELEN 665 RF Communication Circuits Laboratory Fall 2010 Laboratory #6: Analysis and Simulation of a CMOS VCO Objectives: To learn the use of periodic

More information

Comparative Analysis of Voltage Controlled Oscillator using CMOS

Comparative Analysis of Voltage Controlled Oscillator using CMOS Indian Journal of Science and Technology, Vol 9(14), DOI: 10.17485/ijst/2016/v9i14/84749, April 2016 ISSN (Print) : 0974-6846 ISSN (Online) : 0974-5645 Comparative Analysis of Voltage Controlled Oscillator

More information

A low supply voltage and wide-tuned CMOS Colpitts VCO

A low supply voltage and wide-tuned CMOS Colpitts VCO This article has been accepted and published on J-STAGE in advance of copyediting. Content is final as presented. IEICE Electronics Express, Vol.* No.*,*-* A low supply voltage and wide-tuned CMOS Colpitts

More information

Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN 37235, USA 2

Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN 37235, USA 2 Rajan Arora 1, S. R. Kulkarni 2, Jerome Mitard 3, 4, Eddy Simoen 3, E. X. Zhang 1, D. M. Fleetwood 1, 5, B. K. Choi 1, R. D. Schrimpf 1, K. F. Galloway 1, M. Meuris 3, and Cor Claeys 3, 4 1 Department

More information

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD Dosimetry Planning CPT Codes: 77295, 77300, 77301, 77306, 77307, 77321, 77316, 77317, 77318, 77331, 77399 Original Date: April, 2011 Last Reviewed

More information

Input Load (ma) Typ.

Input Load (ma) Typ. 1. Features Wide 2 : 1 Input Range Low Ripple And Noise Input / Output Isolation 1.5K Vdc Or K Vdc 100% Burn-In Input - Filter Custom Design Available Net Weight : 12 g / g Typical RoHS Converter Certified

More information

Product Family Part Number CCT. LUXEON D L130-xxyy003000W21 white

Product Family Part Number CCT. LUXEON D L130-xxyy003000W21 white Philips Lumileds IESNA LM-80 Test Report Philips Lumileds IESNA LM-80 Test Report 1. Applicable LUXEON Series part number(s) This IESNA LM-80 Test Report applies to the following LUXEON part numbers: Product

More information

Product Family Part Number Nominal CCT LUXEON D L W K LUXEON D L W K

Product Family Part Number Nominal CCT LUXEON D L W K LUXEON D L W K Philips Lumileds IESNA LM-80 Test Report Philips Lumileds IESNA LM-80 Test Report 1. Applicable LUXEON Series part number(s) This IESNA LM-80 Test Report applies to the following LUXEON part numbers: Product

More information

Current Testing Procedure for Deep Submicron Devices

Current Testing Procedure for Deep Submicron Devices Current Testing Procedure for Deep Submicron Devices Anton Chichkov Dirk Merlier Peter Cox anton.chichkov@mie.alcatel.be dirk.merlier@mie.alcatel.be peter.cox@mie.alcatel.be Alcatel Microelectronics Westerring

More information

HIGH-VOLTAGE SUPER-JUNCTION SOI-LDMOSFETS WITH REDUCED DRIFT LENGTH

HIGH-VOLTAGE SUPER-JUNCTION SOI-LDMOSFETS WITH REDUCED DRIFT LENGTH HIGH-VOLTAGE SUPER-JUNCTION SOI-LDMOSFETS WITH REDUCED DRIFT LENGTH J.M. Park, T. Grasser, and S. Selberherr Institute for Microelectronics, TU Vienna Gußhausstraße 27 29/E360, A 1040 Vienna, Austria Abstract.

More information

Determination of Iodine in Biological Materials using Instrumental Neutron Activation and Anti-coincidence Gamma-ray Spectrometry

Determination of Iodine in Biological Materials using Instrumental Neutron Activation and Anti-coincidence Gamma-ray Spectrometry AU9817352 Determination of Iodine in Biological Materials using Instrumental Neutron Activation and Anti-coincidence Gamma-ray Spectrometry W ZHANG and A CHATT Trace Analysis Research Centre, Department

More information

LIMITED-LIFE ITEMS ANALYSIS FOR THE GLAST Anti-Coincidence Detector (ACD)

LIMITED-LIFE ITEMS ANALYSIS FOR THE GLAST Anti-Coincidence Detector (ACD) CDR REVISION Page 1 of 10 LIMITED-LIFE S ANALYSIS FOR THE GLAST Anti-Coincidence Detector (ACD) LAT-TD-01123-01 ACD-RPT-000039 Revision - October 21, 2002 Goddard Space Flight Center Greenbelt, Maryland

More information

Standard Products ACT15530 CMOS Manchester Encoder / Decoder May 16, 2005

Standard Products ACT15530 CMOS Manchester Encoder / Decoder  May 16, 2005 Standard Products ACT15530 CMOS Manchester Encoder / Decoder www.aeroflex.com/avionics May 16, 2005 FEATURES MIL-STD-1553 Compatible 1.25 Megabit/sec Maximum Data Rate Sync Identification and Lock-in Clock

More information

Contents. Helpline No. UK/ North Ireland Rep. Ireland Web Support Model Number: 12005

Contents. Helpline No. UK/ North Ireland Rep. Ireland Web Support   Model Number: 12005 Contents 1 02 03 04 06 07 11 12 13 15 17 18 19 19 Contents Welcome Safety Instructions Box Contents Notes on Measurements Getting Started Measuring Weight Saving Personal Data Measuring Body Fat, Water

More information

Module 34: Legal aspects, ADI and GRAS status of food additives

Module 34: Legal aspects, ADI and GRAS status of food additives Paper No.: 13 Paper Title: FOOD ADDITIVES Module 34: Legal aspects, ADI and GRAS status of food additives 34.1 Legal Aspects of Food Additives The data provided by Joint Expert Committee on Food Additives

More information

Y FILMS DOSIMETR Nederland België / Belgique

Y FILMS DOSIMETR Nederland België / Belgique DOSIMETRY FILMS GAFCHROMIC Dosimetry Films The Self-developing Dosimetry Films that Allow You to Go Filmless Do away with the cost and headache of calibrating and maintaining a processor Do away with hazardous

More information

Standardization of Nuclear Component Off-Carrier Processing. ASTM E61 New Orleans, LA January 27, 2015 Ryan Tracy, STERIS Isomedix Services

Standardization of Nuclear Component Off-Carrier Processing. ASTM E61 New Orleans, LA January 27, 2015 Ryan Tracy, STERIS Isomedix Services Standardization of Nuclear Component Off-Carrier Processing ASTM E61 New Orleans, LA January 27, 2015 Ryan Tracy, STERIS Isomedix Services History of Nuclear Component Processing Nuclear components processed

More information

Measurement of Dose Rate Dependence of Radiation Induced Damage to the Current Gain in Bipolar Transistors 1

Measurement of Dose Rate Dependence of Radiation Induced Damage to the Current Gain in Bipolar Transistors 1 Measurement of Dose Rate Dependene of Radiation Indued Damage to the Current Gain in Bipolar Transistors 1 D. Dorfan, T. Dubbs, A. A. Grillo, W. Rowe, H. F.-W. Sadrozinski, A. Seiden, E. Spener, S. Stromberg,

More information

COMMITMENT. &SOLUTIONS Act like someone s life depends on what we do. TAKE THE FUZE SAFETY DESIGN QUIZ, PART I UNPARALLELED

COMMITMENT. &SOLUTIONS Act like someone s life depends on what we do. TAKE THE FUZE SAFETY DESIGN QUIZ, PART I UNPARALLELED TAKE THE FUZE SAFETY DESIGN QUIZ, PART I 61 st NDIA Fuze Conference, May 2018 Presented by: Homesh Lalbahadur Army Fuze Management Office ENTERPRISE AND SYSTEMS INTEGRATION CENTER (ESIC) / ARDEC UNPARALLELED

More information

Market Survey. Technical Description Irradiation Tests

Market Survey. Technical Description Irradiation Tests EDMS No. 1959184 The R2E Project Group Code: EN-STI Market Survey Technical Description Irradiation Tests Abstract This Technical Description concerns the performance of irradiation testing of CERN samples.

More information

STUDY ON APPLICATION OF STRAIN MEASURING TECHNOLOGY IN BOARD LEVEL ASSEMBLY PROCESS

STUDY ON APPLICATION OF STRAIN MEASURING TECHNOLOGY IN BOARD LEVEL ASSEMBLY PROCESS As originally published in the SMTA Proceedings STUDY ON APPLICATION OF STRAIN MEASURING TECHNOLOGY IN BOARD LEVEL ASSEMBLY PROCESS Yabing Zou, Daojun Luo, Weiming Li China Electronic Product Reliability

More information

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy C. Talamonti a*, M. Bucciolini a, L. Marrazzo a, D. Menichelli a. a) Department

More information

Good manufacturing practices (GMP) utilized on human blood irradiation process

Good manufacturing practices (GMP) utilized on human blood irradiation process Artigos Good manufacturing practices (GMP) utilized on human blood irradiation process Cláudio Boghi Pesquisador do IPEN-USP. cboghi@uol.com.br; cboghi@usp.br Dorlivete M. Shitsuka Professora de Organização

More information

FOOD ACT No.26 OF 1980

FOOD ACT No.26 OF 1980 FOOD ACT No.26 OF 1980 REGULATIONS made by the Minister of Health in consultation with the Food Advisory Committee under section 32 of the Food Act No. 26 of 1980. Colombo 15 th November, 2005 Nimal Siripala

More information

TSH Series, 2 Watt. 12 VDC 165 ma 82 % TSH 1212D ±12 VDC ±80 ma 82 % TSH 1215D ±15 VDC ±65 ma 82 % TSH 2405S 5 VDC 400 ma 78 % TSH 2412S 24 VDC ±10%

TSH Series, 2 Watt. 12 VDC 165 ma 82 % TSH 1212D ±12 VDC ±80 ma 82 % TSH 1215D ±15 VDC ±65 ma 82 % TSH 2405S 5 VDC 400 ma 78 % TSH 2412S 24 VDC ±10% TSH Series, 2 Watt Features Ultra compact SMD package (SOIC-14/18) Isolated single and dual output models I/O isolation 1 000 VDC High efficiency up to 82% Operating temperature 40 C to +85 C Reflow solder

More information

Stepper Motors and Control Part II - Bipolar Stepper Motor and Control (c) 1999 by Rustle Laidman, All Rights Reserved

Stepper Motors and Control Part II - Bipolar Stepper Motor and Control (c) 1999 by Rustle Laidman, All Rights Reserved Copyright Notice: (C) June 2000 by Russell Laidman. All Rights Reserved. ------------------------------------------------------------------------------------ The material contained in this project, including

More information

EVALUATING THE UNCERTAINTY OF MEASUREMENT ON BLOOD'S GLUCOSE LEVEL

EVALUATING THE UNCERTAINTY OF MEASUREMENT ON BLOOD'S GLUCOSE LEVEL BIOMEDICAL ENGINEERING- APPLICATIONS, BASIS & COMMUNICATIONS EVALUATING THE UNCERTAINTY OF MEASUREMENT ON BLOOD'S GLUCOSE LEVEL 91 HUNG-CHUN HUANG 1,2, CHIA-HUNG CHIEN 1,2, CHENG-YI WANG 1, FOK-CHING CHONG

More information

Review of Veterinary Epidemiologic Research by Dohoo, Martin, and Stryhn

Review of Veterinary Epidemiologic Research by Dohoo, Martin, and Stryhn The Stata Journal (2004) 4, Number 1, pp. 89 92 Review of Veterinary Epidemiologic Research by Dohoo, Martin, and Stryhn Laurent Audigé AO Foundation laurent.audige@aofoundation.org Abstract. The new book

More information

Viability of Low Temperature Deep and Ultra Deep Submicron Scaled Bulk nmosfets on Ultra Low Power Applications

Viability of Low Temperature Deep and Ultra Deep Submicron Scaled Bulk nmosfets on Ultra Low Power Applications Journal of Electron Devices, Vol. 11, 2011, pp. 567-575 JED [ISSN: 1682-3427 ] Viability of Low Temperature Deep and Ultra Deep Submicron Scaled Bulk nmosfets on Ultra Low Power Applications Subhra Dhar

More information

Application Note 201

Application Note 201 201 Application note: Determination of the of Milk Application note no.: 201 By: E. de Jong Date: January 2001 Copyright Delta Instruments 2005 www.deltainstruments.com Table of contents Table of contents

More information

Design of Low-Power CMOS Cell Structures Using Subthreshold Conduction Region

Design of Low-Power CMOS Cell Structures Using Subthreshold Conduction Region International Journal of Scientific & Engineering Research, Volume 2, Issue 2, February-2011 1 Design of Low-Power CMOS Cell Structures Using Subthreshold Conduction Region Vishal Sharma, Sanjay Kumar

More information

Standard Operating Procedure for Cycle Ergometry on Monarks

Standard Operating Procedure for Cycle Ergometry on Monarks Standard Operating Procedure for Cycle Ergometry on Monarks Effective date: 26.07.2017 Review due date: 26.04.2019 Original Author Name: Richard Metcalfe Position: Ph.D. Student Date: 14.12.2012 Reviewer

More information

D DAVID PUBLISHING. Uncertainties of in vivo Dosimetry Using Semiconductors. I. Introduction. 2. Methodology

D DAVID PUBLISHING. Uncertainties of in vivo Dosimetry Using Semiconductors. I. Introduction. 2. Methodology Journal of Life Sciences 9 (2015) 120-126 doi: 10.17265/1934-7391/2015.03.005 D DAVID PUBLISHING Uncertainties of in vivo Dosimetry Using Semiconductors Zeina Al Kattar, Hanna El Balaa and Saeed Zahran

More information

Leakage Currents of Zinc Oxide Surge Arresters in 22 kv Distribution System Using Thermal Image Camera

Leakage Currents of Zinc Oxide Surge Arresters in 22 kv Distribution System Using Thermal Image Camera Journal of Power and Energy Engineering, 2014, 2, 712-717 Published Online April 2014 in SciRes. http://www.scirp.org/journal/jpee http://dx.doi.org/10.4236/jpee.2014.24095 Leakage Currents of Zinc Oxide

More information

SEMICON West Standards Meeting Schedule San Francisco Marriott Marquis and Moscone Center (North Hall), San Francisco, CA. Sunday, July 8, 2012

SEMICON West Standards Meeting Schedule San Francisco Marriott Marquis and Moscone Center (North Hall), San Francisco, CA. Sunday, July 8, 2012 and Moscone Center (North Hall), San Francisco, CA 1 1 1 Sunday, July 8, 2012 NARSC Regulations -1 Informal Working Session for ISC Regulations (SC) -1 (15) JA NA Regional Standards Committee (NARSC) 1-21:00

More information

GENERAL STANDARD FOR THE LABELLING OF FOOD ADDITIVES WHEN SOLD AS SUCH CODEX STAN Adopted in Revision: 2016.

GENERAL STANDARD FOR THE LABELLING OF FOOD ADDITIVES WHEN SOLD AS SUCH CODEX STAN Adopted in Revision: 2016. GENERAL STANDARD FOR THE LABELLING OF FOOD ADDITIVES WHEN SOLD AS SUCH CODEX STAN 107-1981 Adopted in 1981. Revision: 2016. CODEX STAN 107-1981 2 1. SCOPE This standard applies to the labelling of food

More information

What is a stepper motor?

What is a stepper motor? What is a stepper motor? 1. A stepper motor (or step motor) is a brushless, synchronous electric motor that can divide a full rotation into a large number of steps. The motor's position can be controlled

More information

CODEX GENERAL STANDARD FOR THE LABELLING OF FOOD ADDITIVES WHEN SOLD AS SUCH CODEX STAN

CODEX GENERAL STANDARD FOR THE LABELLING OF FOOD ADDITIVES WHEN SOLD AS SUCH CODEX STAN CODEX STAN 107 Page 1 of 5 1. SCOPE CODEX GENERAL STANDARD FOR THE LABELLING OF FOOD ADDITIVES WHEN SOLD AS SUCH CODEX STAN 107-1981 1 This standard applies to the labelling of "food additives" sold as

More information

Hydrogen-Sensing Characteristics of Palladium-Doped Zinc-Oxide Nanostructures

Hydrogen-Sensing Characteristics of Palladium-Doped Zinc-Oxide Nanostructures Hydrogen-Sensing Characteristics of Palladium-Doped Zinc-Oxide Nanostructures Undergraduate Researcher Saranya Sathananthan University of Tennessee, Knoxville Faculty Mentor Vinayak P. Dravid Department

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60601-2-37 2001 AMENDMENT 1 2004-08 Amendment 1 Medical electrical equipment Part 2-37: Particular requirements for the safety of ultrasonic medical diagnostic and monitoring

More information

MicroSwitcher TMS Series 6, 10, 15, 25 Watt

MicroSwitcher TMS Series 6, 10, 15, 25 Watt Features Ultraminiature AC/DC Switching Power Supply Modules Fully encapsulated Plastic Package Universal Input 85-264 VAC, 50/60 Hz High Efficiency Low Ripple and Noise Overload Protection EMI meets EN

More information

Model 3500 Manual TLD Reader with WinREMS 3500-W-O-0602 Page 5-1 Operator's Manual

Model 3500 Manual TLD Reader with WinREMS 3500-W-O-0602 Page 5-1 Operator's Manual Model 35 Manual TLD Reader with WinREMS 35-W-O-62 Page 5-1 5. Quality Assurance The procedures in this section help you maintain the accuracy and reliability of your Model 35. The main topics covered are:!

More information

5th ADAMAS Workshop at GSI December 15-16, 2016, Darmstadt, Germany

5th ADAMAS Workshop at GSI December 15-16, 2016, Darmstadt, Germany Evaluation of 3D diamond detectors for application in medical radiation dosimetry K. Kanxheri (1,2), L. Servoli (2), C. Zucchetti (5), A. C. Dipilato (5), M. Iacco (5), S. Lagomarsino (3,4), A. Morozzi

More information

Calculation methods in Hermes Medical Solutions dosimetry software

Calculation methods in Hermes Medical Solutions dosimetry software Calculation methods in Hermes Medical Solutions dosimetry software Helena McMeekin MSc. Clinical Applications Scientist, Hermes Medical Solutions MRTDosimetry Scientific Workshop The Principals and Clinical

More information

EE 4BD4 Lecture 20. Therapeutic Stimulation

EE 4BD4 Lecture 20. Therapeutic Stimulation EE 4BD4 Lecture 20 Therapeutic Stimulation 1 2 Extracellular Stimulation (at cathode) 3 4 Design of FES (cont.): Example stimulus waveform shapes: monophasic, biphasic, chopped, triphasic, and asymmetric,

More information

Correlating Trust with Signal Detection Theory Measures in a Hybrid Inspection System

Correlating Trust with Signal Detection Theory Measures in a Hybrid Inspection System Correlating Trust with Signal Detection Theory Measures in a Hybrid Inspection System Xiaochun Jiang Department of Industrial and Systems Engineering North Carolina A&T State University 1601 E Market St

More information

MODELLING A GAMMA IRRADIATION PROCESS USING THE MONTE CARLO METHOD

MODELLING A GAMMA IRRADIATION PROCESS USING THE MONTE CARLO METHOD 2011 International Nuclear Atlantic Conference - INAC 2011 Belo Horizonte, MG, Brazil, October 24-28, 2011 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-04-5 MODELLING A GAMMA IRRADIATION

More information

Pb-Free/RoHS Solutions

Pb-Free/RoHS Solutions Pb-Free/RoHS Solutions Environmental Policy: Exar Corporation is committed to protecting the environment and individual health and safety. We shall comply with all environmental regulations, health and

More information

Albert Lisbona Medical Physics Department CLCC Nantes Atlantique a

Albert Lisbona Medical Physics Department CLCC Nantes Atlantique a The Equipment : safety, commissioning, re commissioning calibration : Equipements : sûreté, recette, modification calibration A medical physicist point of view. Albert Lisbona Medical Physics Department

More information

A study on the transmittivity of Tyvek

A study on the transmittivity of Tyvek A study on the transmittivity of Tyvek Alvaro Chavarria, Physics Department, Duke University June 20, 2005 Abstract In this experiment the transmittivity of Tyvek (Dupont, 1073B) was studied. Results were

More information

Section 7 ALARA Program

Section 7 ALARA Program Page 7-1 Section 7 ALARA Program Contents A. ALARA Principle... 7-2 1. Biological Basis... 7-2 2. Applied Practices... 7-3 3. Operational Dose Limits... 7-3 4. Collective Dose... 7-3 B. Radiation Safety

More information

MSD P13038 Hearing Aid Design. Final Review May 10, 2013

MSD P13038 Hearing Aid Design. Final Review May 10, 2013 MSD P13038 Hearing Aid Design Final Review May 10, 2013 Agenda 5.10.13 Project Overview (2) Mechanical Needs & Spec Review (10) Electrical & Computer Needs & Spec Review (10) Budget Review (2) Schedule

More information

Characteristics of Liquids Atomization Using Surface Acoustic Wave

Characteristics of Liquids Atomization Using Surface Acoustic Wave Characteristics of Liquids Atomization Using Surface Acoustic Wave Minoru Kurosawa, Akira Futami, and Toshiro Higuchi Dept. of Precision Machinery Engineering, The University of Tokyo, Hongo, Bunkyo-ku,

More information

Infrastructure for Rapid Assessment of Reliability

Infrastructure for Rapid Assessment of Reliability Infrastructure for Rapid Assessment of Reliability Infrastructure and process improvements in the reliability testing of a high density microelectronic packaging technology Hannah Varner Draper Outline

More information

Standard Errors and Uncertainty in Agentbased

Standard Errors and Uncertainty in Agentbased Standard Errors and Uncertainty in Agentbased Models Presented by Georgiy Bobashev RTI International Presented at NISS Workshop April, 2011 3040 Cornwallis Road P.O. Box 12194 Research Triangle Park, NC

More information

Clinical Applications of Brachytherapy Radiobiology. Radiobiology is Essential

Clinical Applications of Brachytherapy Radiobiology. Radiobiology is Essential Clinical Applications of Brachytherapy Radiobiology Dr Alexandra Stewart University of Surrey St Luke s Cancer Centre Guildford, England Radiobiology is Essential Knowledge of radiobiological principles

More information

Operations Manual. Far West Technology, Inc. September, Revision 2A. 330 D South Kellogg Ave. Goleta, California USA

Operations Manual. Far West Technology, Inc. September, Revision 2A. 330 D South Kellogg Ave. Goleta, California USA MODEL FWT-92D Radiachromic Reader Operations Manual September, 1996 Revision 2A Far West Technology, Inc. 330 D South Kellogg Ave. Goleta, California 93117 USA MODEL FWT-92D RADIACHROMIC READER PAGE 1

More information

Neutron Induced Radiation Damage in BaF 2, LYSO and PWO Scintillation Crystals

Neutron Induced Radiation Damage in BaF 2, LYSO and PWO Scintillation Crystals Neutron Induced Radiation Damage in BaF 2, LYSO and PWO Scintillation Crystals Chen Hu, Fan Yang, Liyuan Zhang, Ren-Yuan Zhu California Institute of Technology Jon Kapustinsky, Ron Nelson and Zhehui Wang

More information

Automatic Definition of Planning Target Volume in Computer-Assisted Radiotherapy

Automatic Definition of Planning Target Volume in Computer-Assisted Radiotherapy Automatic Definition of Planning Target Volume in Computer-Assisted Radiotherapy Angelo Zizzari Department of Cybernetics, School of Systems Engineering The University of Reading, Whiteknights, PO Box

More information

SSO Simulation with IBIS

SSO Simulation with IBIS SSO Simulation with IBIS Manfred Maurer manfred.maurer@siemens.com Industrial Solutions and Services Your Success is Our Goal www.siemens.de/edh Manfred Maurer Folie 1 Motivation SSN with IBIS in 2000

More information

Oral cavity cancer Post-operative treatment

Oral cavity cancer Post-operative treatment Oral cavity cancer Post-operative treatment Dr. Christos CHRISTOPOULOS Radiation Oncologist Centre Hospitalier Universitaire (C.H.U.) de Limoges, France Important issues RT -techniques Patient selection

More information

B Bibliography. TOC Index. Quit file

B Bibliography. TOC Index. Quit file B 359 [1] R. S. Muller and T. I. Kamins, Device electronics for integrated circuits. Wiley, New York, 2nd ed., 1986. [2] S.M. Sze, Physics of Semiconductor Devices. Wiley, New York, 2 ed., 1981. [3] P.

More information

About bioassay of Oximes:? New isolation alternatives from biomatrices? Chromatographic separation issues? Reserve on using MS or MS/MS detection

About bioassay of Oximes:? New isolation alternatives from biomatrices? Chromatographic separation issues? Reserve on using MS or MS/MS detection State of the art: xime-type AChE Reactivators: Wide use as antidotes in organo phosphorous compounds poisoning; Synthesis of new congeners; Intense studies on their transfer through BBB; Intense studies

More information

REVISED CODEX GENERAL STANDARD FOR IRRADIATED FOODS CODEX STAN , REV

REVISED CODEX GENERAL STANDARD FOR IRRADIATED FOODS CODEX STAN , REV Irradiated foods Page 1 of 10 1. SCOPE REVISED CODEX GENERAL STANDARD FOR IRRADIATED FOODS CODEX STAN 106-1983, REV.1-2003 This standard applies to foods processed by ionizing radiation that is used in

More information

SO14 IC Serial Output IC For 14 Bits of Output

SO14 IC Serial Output IC For 14 Bits of Output ABCircuits www.abcircuits.com POB New Hill () 0-0 General Description SO IC Serial Output IC For Bits of Output The SO IC is designed to provide bits of output data to connect to RS-, RS-, USB, Ethernet

More information

For general queries, contact

For general queries, contact Much of the work in Bayesian econometrics has focused on showing the value of Bayesian methods for parametric models (see, for example, Geweke (2005), Koop (2003), Li and Tobias (2011), and Rossi, Allenby,

More information

Radiobiological principles of brachytherapy

Radiobiological principles of brachytherapy Radiobiological principles of brachytherapy Low dose rate (LDR) Medium dose rate (MDR) High dose rate (HDR) The effect of dose rate As the dose rate is decreased, there is more time during irradiation

More information

A Very Fast and Radiation Hard BaF 2 Calorimeter for Mu2e-II. Ren-Yuan Zhu

A Very Fast and Radiation Hard BaF 2 Calorimeter for Mu2e-II. Ren-Yuan Zhu A Very Fast and Radiation Hard BaF 2 Calorimeter for Mu2e-II Ren-Yuan Zhu California Institute of Technology December 8, 2017 Mu2e-II Workshop at ANL Introduction Mu2e-I is building a pure CsI calorimeter,

More information

Estimating Risk of Low Radiation Doses (from AAPM 2013) María Marteinsdóttir Nordic Trauma,

Estimating Risk of Low Radiation Doses (from AAPM 2013) María Marteinsdóttir Nordic Trauma, Estimating Risk of Low Radiation Doses (from AAPM 2013) María Marteinsdóttir Nordic Trauma, 20140521 Stochastic effects Linear No Threshold - LNT-model Uncertain Material produced by William R. Hendee

More information

Power Turn-On. IEEE 802.3af DTE Power via MDI March Dieter Knollman AVAYA

Power Turn-On. IEEE 802.3af DTE Power via MDI March Dieter Knollman AVAYA Power Turn-On IEEE 802.3af DTE Power via MDI March 2001 Dieter Knollman AVAYA djhk@netzero.net 1 Outline Simulate Power in PSE and PD Switches Switch Junction Temperature Examine PSE Current Limiting Options

More information

To investigate the safe levels of radiotherapy administered to patients who have an implanted cardiac device.

To investigate the safe levels of radiotherapy administered to patients who have an implanted cardiac device. 043 Lauren Evans To investigate the safe levels of radiotherapy administered to patients who have an implanted cardiac device. 4061.40 Summary With an ageing UK population, the number of patients with

More information

ISO INTERNATIONAL STANDARD. Implants for surgery Active implantable medical devices Part 2: Cardiac pacemakers

ISO INTERNATIONAL STANDARD. Implants for surgery Active implantable medical devices Part 2: Cardiac pacemakers INTERNATIONAL STANDARD ISO 14708-2 Second edition 2012-08-15 Implants for surgery Active implantable medical devices Part 2: Cardiac pacemakers Implants chirurgicaux Dispositifs médicaux implantables actifs

More information

Updating WENRA Reference Levels for existing reactors in the light of TEPCO Fukushima Dai-ichi accident lessons learned

Updating WENRA Reference Levels for existing reactors in the light of TEPCO Fukushima Dai-ichi accident lessons learned Updating WENRA Reference Levels for existing reactors in the light of TEPCO Fukushima Daiichi accident lessons learned November 2013 Table of Content Updating WENRA Reference Levels for existing reactors

More information

A low magnification SEM image of the fabricated 2 2 ZnO based triode array is

A low magnification SEM image of the fabricated 2 2 ZnO based triode array is Chapter 6 Characteristics of Field Emission Triode 6.1 Planar Gated Field Emission Triode 6.1.1 Structural and Electrical Analysis A low magnification SEM image of the fabricated 2 2 ZnO based triode array

More information

2016 Children and young people s inpatient and day case survey

2016 Children and young people s inpatient and day case survey NHS Patient Survey Programme 2016 Children and young people s inpatient and day case survey Technical details for analysing trust-level results Published November 2017 CQC publication Contents 1. Introduction...

More information

Breast Cancer. What is breast cancer?

Breast Cancer. What is breast cancer? Scan for mobile link. Breast Cancer Breast cancer is a malignant tumor in or around breast tissue. It usually begins as a lump or calcium deposit that develops from abnormal cell growth. Most breast lumps

More information

Heart Abnormality Detection Technique using PPG Signal

Heart Abnormality Detection Technique using PPG Signal Heart Abnormality Detection Technique using PPG Signal L.F. Umadi, S.N.A.M. Azam and K.A. Sidek Department of Electrical and Computer Engineering, Faculty of Engineering, International Islamic University

More information

Chapter VI Development of ISFET model. simulation

Chapter VI Development of ISFET model. simulation Chapter VI Development of ISFET model using ZnO as gate and its simulation Introduction Theory of ISFET Experimental work Results and discussion Conclusion 6.1 General: The human bodies ph and electrolyte

More information

Design and Implementation of Programmable Hearing Aid Using FPAA

Design and Implementation of Programmable Hearing Aid Using FPAA Design and Implementation of Programmable Hearing Aid Using FPAA Priya. K *1 and P. Eswaran *2 *Department of Electronics and Communication Engineering, SRM University, Chennai, Tamilnadu-603 203 Abstract.

More information

PERSONNEL MONITORING AND DOSIMETRY POLICIES

PERSONNEL MONITORING AND DOSIMETRY POLICIES PERSONNEL MONITORING AND DOSIMETRY POLICIES All individuals who are required to have their exposure to ionizing radiation monitored must be trained prior to using the source(s) of radiation. The radioactive

More information

A 1.2V operation 5 GHz CMOS VCO with series

A 1.2V operation 5 GHz CMOS VCO with series Adanced Science and Technology Letters, pp.3-7 http://dx.doi.org/0.4257/astl.204.75.04 A.2V operation 5 GHz CMOS VCO with series aractor bank Mi-young Lee Dept. of Electronic Eng., Hannam Uniersity, Ojeong

More information

Analog Design and System Integration Lab. Graduate Institute of Electronics Engineering National Taiwan University

Analog Design and System Integration Lab. Graduate Institute of Electronics Engineering National Taiwan University Designs of Low-Noise K-band K VCO Analog Design and System Integration Lab. Graduate Institute of Electronics Engineering National Taiwan University Introduction Outlines The proposed VCO architecture

More information

KINGS COLLEGE OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK. Subject Name: ELECTRONICS AND MICRIPROCESSORS UNIT I

KINGS COLLEGE OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK. Subject Name: ELECTRONICS AND MICRIPROCESSORS UNIT I KINGS COLLEGE OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK Subject Name: ELECTRONICS AND MICRIPROCESSORS UNIT I Year/Sem:II / IV PART-A(2 MARKS) SEMICONDUCTORS AND RECTIFIERS 1. What

More information

VIAVI IFR6000 DME Mode Signal Generator Reply Pulse Width Output Frequency Echo Reply Output Level Reply Pulse Rise and Fall Times (all pulses)

VIAVI IFR6000 DME Mode Signal Generator Reply Pulse Width Output Frequency Echo Reply Output Level Reply Pulse Rise and Fall Times (all pulses) Specification Sheet VIAVI IFR6000 Transponder/DME/TCAS Flight Line Test Set VIAVI Solutions DME Mode A 5-minute warm-up period is required for all specifications. Output Reply : 962 to 1213 MHz : Output

More information

SEVENTH INTERNATIONAL WORKSHOP ON DOSIMETRY FOR RADIATION PROCESSING

SEVENTH INTERNATIONAL WORKSHOP ON DOSIMETRY FOR RADIATION PROCESSING INTRODUCTION ASTM Subcommittee E10.01, Radiation Processing: Dosimetry and Applications, is proud to present the seventh edition of our International Workshop on Dosimetry for Radiation Processing. This

More information

David Hunter Cell Color Measurement on Budget. Audience

David Hunter Cell Color Measurement on Budget. Audience Audience Creative/ Brand Owner! You own - your suppliers, producers own instrument! How well do they match! Use one Instrument for Spot, and different one for Process? Production/ Press Press! Proofer

More information

Low-Power 1-bit CMOS Full Adder Using Subthreshold Conduction Region

Low-Power 1-bit CMOS Full Adder Using Subthreshold Conduction Region International Journal of Scientific & Engineering Research Volume 2, Issue 6, June-2011 1 Low-Power 1-bit CMOS Full Adder Using Subthreshold Conduction Region Vishal Sharma, Sanjay Kumar Abstract In balancing

More information