MALDI Mass Spectrometry: A Label-Free Solution for Ultra-High-Throughput Screening

Size: px
Start display at page:

Download "MALDI Mass Spectrometry: A Label-Free Solution for Ultra-High-Throughput Screening"

Transcription

1 MALDI Mass Spectrometry: A Label-Free Solution for Ultra-High-Throughput Screening MIPTEC Conference 2016 Meike Hamester, Jens Fuchser Bruker Daltonik, Bremen 1

2 MALDI PharmaPulse for: Biochemical Screening Enzyme small molecule interactions Fluorescence label Fluorescence label > compounds Typically fluorescence-based technologies are used for HTS/ultra HTS in Drug Discovery Typical HTS campaigns have 1-3% hit rates of which a significant proportion may be false positives or assay artefacts Numerous sections need to be performed to reduce hits down to manageable numbers risk of leaving the real hits behind Lengthy hit qualification occurs at the end of a screen to find the true hits using label-free or biophysical techniques Why Mass Spectrometry? Highly sensitive technique Direct quantification of substrate and product (label free) Eliminates need to develop specific antibodies or fluorescent labels Decreased risk of interference Fast assay development Low cost per well

3 MALDI TOF Basic principle of MALDI-Time-of-Flight mass analysis

4 Mass Spectrometry in Drug Discovery Hit Identification Primary HTS (Millions) Fluorescence Hit Confirmation 10,000s MALDI MS SPE MS Dose Response Confirmation (100 s) Hit Characterisation (hit to candidate) SAR/Selectivity Screening (100 s) Mechanism of Action/Kinetics (10 s) Off target effects/safety pharmacology (DMPK) (100 s) Multiplex LC MS/MS

5 Typical Applications of MALDI-TOF rapiflex MALDI TOF/TOF

6 rapiflex MALDI TOF Mass Spectrometry From Imaging to uhts 2 khz 10 khz Laser Smartbeam technology: HTS benefits from all those enhancements: Parallelization of the processes Laser/stage movement ( Run and Shoot ) & data processing Nd:YAG Laser Nd:YAG Laser: Smartbeam Cleaning: no high throughput with frequent cleaning

7 MALDI MS Imaging rapiflex (TOF/TOF) Drug Distribution in rat lung tissue 4mg CHCA matrix, sublimation 20µm pixel resolution, positions, 400 laser shots/position, Analysis time: 41 mins Samples courtesy of Peter Marshall, GSK 7

8 MALDI MS Imaging - rapiflex (TOF/TOF) Drug Distribution in rat lung tissue 4mg CHCA matrix, sublimation (Bruker Home-built device) 5µm pixel resolution, positions, 400 laser shots/position, Analysis time: 36 mins Samples courtesy of Peter Marshall, GSK 8

9 Speed -> huge throughput rapiflex: designed to accelarate imaging However, it meets all requirements of uhts Robustness -> constant operation Definition -> superior image quality 30-Sep samples on MPP Sample Plate

10 Typical Applications of MALDI-TOF Challenges to apply MALDI to HTS and uhts Fully automatic sample plate change every 8-10 min Fully automatic sample preparation ( spotting ) Robustness to analyze 2-3 mio samples without intervention Fit for purpose software package Cost per sample

11 Automation Fully automatic MALDI TOF uhts Courtesy of : CyBio / Analytik Jena 11

12 MALDI Sample Plate Preparation LABCYTE ECHO CyBio CyBi-Well 1536 Analytik Jena 30-Sep-16 12

13 MALDI TOF: Correlation with SPE Mass Spectrometry R=0,83 JMJD2c R=0,95 Acetylcholinesterase Courtesy of Melanie Leveridge (GSK Stevenage, UK)

14 NEW DUB Assay for MALDI TOF Courtesy of: Matthias Trost, University of Dundee

15 Assay transformation TR-Fret MALDI LC-MS SPE-MS

16 Assay Development Support for MALDI 384 MALDI Plate with different assay preparations and acquisition conditions 16

17 A How Can we Further Boost Throughput? Beyond B Increasing spot density from 1536 to 6144 per target can save 5 minutes per 1536 well plate ~ 100 hours over a 2 million compound screening campaign 1 7

18 The Boost for Higher Throughput New laser technology enables up to 20X speed compared to existing instruments We have demonstrated read times of 9.2 minutes/6144 spotted target and 7.3 minutes/1536 spotted target for the ACHe assay.

19 Summary The development of a 10 khz MALDI-TOF instrument (rapiflex) allows label free High Throughput Screening Automation of the rapiflex MALDI TOF fulfils the requirements for uhts and can be used in primary screening campaigns MS for primary screens Label-free 1536 well plate format 6144 possible Sample time: rapiflex: sec 100 x less solvent (& waste) compared to SPE/ LC-MS Low cost (2-3 cent per well) Sample volume nl multiple sampling per well time course studies

20 Thank you! 20

21 True 64-bit application: improved handling of FTMS datasets Skyline projection: shows highest intensity mass signal in dataset, making signals present only in small areas easy to find Integrated Spatial Segmentation using Hierarchal Clustering Rapid classification of up to 50,000 spectra without the need for exporting to external programs 21

Technical Note # TN-31 Redefining MALDI-TOF/TOF Performance

Technical Note # TN-31 Redefining MALDI-TOF/TOF Performance Bruker Daltonics Technical Note # TN-31 Redefining MALDI-TOF/TOF Performance The new ultraflextreme exceeds all current expectations of MALDI-TOF/TOF technology: A proprietary khz smartbeam-ii TM MALDI

More information

MALDI Imaging Drug Imaging Detlev Suckau Head of R&D MALDI Bruker Daltonik GmbH. December 19,

MALDI Imaging Drug Imaging Detlev Suckau Head of R&D MALDI Bruker Daltonik GmbH. December 19, MALDI Imaging Drug Imaging Detlev Suckau Head of R&D MALDI Bruker Daltonik GmbH December 19, 2014 1 The principle of MALDI imaging Spatially resolved mass spectra are recorded Each mass signal represents

More information

Bruker Daltonics. autoflex III smartbeam. The Standard in MALDI-TOF Performance MALDI-TOF/TOF. think forward

Bruker Daltonics. autoflex III smartbeam. The Standard in MALDI-TOF Performance MALDI-TOF/TOF. think forward Bruker Daltonics autoflex III smartbeam The Standard in MALDI-TOF Performance think forward MALDI-TOF/TOF Designed for a Routine High Level of Performance The autoflex III smartbeam brings the power of

More information

FPO. Label-Free Molecular Imaging. Innovation with Integrity. Discover, localize and quantify biochemical changes and molecular markers

FPO. Label-Free Molecular Imaging. Innovation with Integrity. Discover, localize and quantify biochemical changes and molecular markers FPO Label-Free Molecular Imaging Discover, localize and quantify biochemical changes and molecular markers Innovation with Integrity Mass Spectrometry Bruker, the global leader in MALDI-MS technology,

More information

Small Molecule Drug Imaging of Mouse Tissue by MALDI-TOF/TOF Mass Spectrometry and FTMS

Small Molecule Drug Imaging of Mouse Tissue by MALDI-TOF/TOF Mass Spectrometry and FTMS Bruker Daltonics Application Note # MT-93/FTMS-38 Small Molecule Drug Imaging of Mouse Tissue by MALDI-TOF/TOF Mass Spectrometry and FTMS Introduction Matrix Assisted Laser Desorption Ionization (MALDI)

More information

Application Note # MT-111 Concise Interpretation of MALDI Imaging Data by Probabilistic Latent Semantic Analysis (plsa)

Application Note # MT-111 Concise Interpretation of MALDI Imaging Data by Probabilistic Latent Semantic Analysis (plsa) Application Note # MT-111 Concise Interpretation of MALDI Imaging Data by Probabilistic Latent Semantic Analysis (plsa) MALDI imaging datasets can be very information-rich, containing hundreds of mass

More information

MALDI Imaging Mass Spectrometry

MALDI Imaging Mass Spectrometry MALDI Imaging Mass Spectrometry Nan Kleinholz Mass Spectrometry and Proteomics Facility The Ohio State University Mass Spectrometry and Proteomics Workshop What is MALDI Imaging? MALDI: Matrix Assisted

More information

The MALDI Biotyper An In Vitro Diagnostic System (IVD) for Identification of Bacteria and Yeasts with a Global Reach

The MALDI Biotyper An In Vitro Diagnostic System (IVD) for Identification of Bacteria and Yeasts with a Global Reach The MALDI Biotyper An In Vitro Diagnostic (IVD) for Identification of Bacteria and Yeasts with a Global Reach The MALDI Biotyper identifies microorganisms using MALDI-TOF (Matrix Assisted Laser Desorption

More information

Sequence Identification And Spatial Distribution of Rat Brain Tryptic Peptides Using MALDI Mass Spectrometric Imaging

Sequence Identification And Spatial Distribution of Rat Brain Tryptic Peptides Using MALDI Mass Spectrometric Imaging Sequence Identification And Spatial Distribution of Rat Brain Tryptic Peptides Using MALDI Mass Spectrometric Imaging AB SCIEX MALDI TOF/TOF* Systems Patrick Pribil AB SCIEX, Canada MALDI mass spectrometric

More information

Supporting information for: Memory Efficient. Principal Component Analysis for the Dimensionality. Reduction of Large Mass Spectrometry Imaging

Supporting information for: Memory Efficient. Principal Component Analysis for the Dimensionality. Reduction of Large Mass Spectrometry Imaging Supporting information for: Memory Efficient Principal Component Analysis for the Dimensionality Reduction of Large Mass Spectrometry Imaging Datasets Alan M. Race,,, Rory T. Steven,, Andrew D. Palmer,,,

More information

Applications for MALDI-TOF Imaging Present and Future

Applications for MALDI-TOF Imaging Present and Future Y Position 8563 / (3000-30000) 12124 / (3000-30000) 14044 / (3000-30000) 10158 35 / (3000-30000) 15012 / (3000-30000) 10894 / (3000-30000) 4964 / (3000-30000) 12414 / (3000-30000) Area Chromatogram - All

More information

Mass Spectrometry. Actual Instrumentation

Mass Spectrometry. Actual Instrumentation Mass Spectrometry Actual Instrumentation August 2017 See also http://www.uni-bielefeld.de/chemie/analytik/ms f additional infmation 1. MALDI TOF MASS SPECTROMETRY ON THE ULTRAFLEX 2 2. ESI MASS SPECTROMETRY

More information

Application Note # LCMS-89 High quantification efficiency in plasma targeted proteomics with a full-capability discovery Q-TOF platform

Application Note # LCMS-89 High quantification efficiency in plasma targeted proteomics with a full-capability discovery Q-TOF platform Application Note # LCMS-89 High quantification efficiency in plasma targeted proteomics with a full-capability discovery Q-TOF platform Abstract Targeted proteomics for biomarker verification/validation

More information

Automated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222

Automated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222 Automated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222 Joan Stevens, Ph.D.; Luke Roenneburg; Tim Hegeman; Kevin Fawcett

More information

Qualitative & Quantitative MS imaging technique for BAK distribution in eye. Stauber Jonathan, PhD CSO ImaBiotech

Qualitative & Quantitative MS imaging technique for BAK distribution in eye. Stauber Jonathan, PhD CSO ImaBiotech Q Qualitative & Quantitative MS imaging technique for BAK distribution in eye Stauber Jonathan, PhD CSO ImaBiotech EBF congress 2012, Bruxelles Q An innovative company with an innovative technology WHAT

More information

New Instruments and Services

New Instruments and Services New Instruments and Services Liwen Zhang Mass Spectrometry and Proteomics Facility The Ohio State University Summer Workshop 2016 Thermo Orbitrap Fusion http://planetorbitrap.com/orbitrap fusion Thermo

More information

The study of phospholipids in single cells using an integrated microfluidic device

The study of phospholipids in single cells using an integrated microfluidic device Supporting Information: The study of phospholipids in single cells using an integrated microfluidic device combined with matrix-assisted laser desorption/ionization mass spectrometry Weiyi Xie,, Dan Gao,

More information

Proteomic Biomarker Discovery in Breast Cancer

Proteomic Biomarker Discovery in Breast Cancer Proteomic Biomarker Discovery in Breast Cancer Rob Baxter Laboratory for Cellular and Diagnostic Proteomics Kolling Institute, University of Sydney, Royal North Shore Hospital robert.baxter@sydney.edu.au

More information

Application Note # MT-91. High Quality MALDI Imaging of Proteins and Peptides in Small Rodent Organ Tissues. Bruker Daltonics.

Application Note # MT-91. High Quality MALDI Imaging of Proteins and Peptides in Small Rodent Organ Tissues. Bruker Daltonics. Bruker Daltonics Application Note # MT-91 18385 Da 6230 Da 7843 Da High Quality MALDI Imaging of Proteins and Peptides in Small Rodent Organ Tissues New developments in MALDI instrumentation, laser technology

More information

Data Independent MALDI Imaging HDMS E for Visualization and Identification of Lipids Directly from a Single Tissue Section

Data Independent MALDI Imaging HDMS E for Visualization and Identification of Lipids Directly from a Single Tissue Section Data Independent MALDI Imaging HDMS E for Visualization and Identification of Lipids Directly from a Single Tissue Section Emmanuelle Claude, Mark Towers, and Kieran Neeson Waters Corporation, Manchester,

More information

Analysis of Peptides via Capillary HPLC and Fraction Collection Directly onto a MALDI Plate for Off-line Analysis by MALDI-TOF

Analysis of Peptides via Capillary HPLC and Fraction Collection Directly onto a MALDI Plate for Off-line Analysis by MALDI-TOF Analysis of Peptides via Capillary HPLC and Fraction Collection Directly onto a MALDI Plate for Off-line Analysis by MALDI-TOF Application Note 219 Joan Stevens, PhD; Luke Roenneburg; Kevin Fawcett (Gilson,

More information

Application Note # MT-94 Direct Read-out of Thin Layer Chromatography (TLC) using MALDI-TOF

Application Note # MT-94 Direct Read-out of Thin Layer Chromatography (TLC) using MALDI-TOF Bruker Daltonics Application Note # MT-94 Direct Read-out of Thin Layer Chromatography (TLC) using MALDI-TOF Thin Layer Chromatography (TLC) is broadly established to separate, characterize and quantify

More information

University of Dundee. Published in: SLAS Discovery DOI: / Publication date: 2017

University of Dundee. Published in: SLAS Discovery DOI: / Publication date: 2017 University of Dundee Identifying Inhibitors of Inflammation Heap, Rachel E.; Hope, Anthony G.; Pearson, Lesley; Reyskens, Kathleen M. S. E.; McElroy, Stuart P.; Hastie, C. James; Porter, David W.; Arthur,

More information

Application Note # ET-17 / MT-99 Characterization of the N-glycosylation Pattern of Antibodies by ESI - and MALDI mass spectrometry

Application Note # ET-17 / MT-99 Characterization of the N-glycosylation Pattern of Antibodies by ESI - and MALDI mass spectrometry Bruker Daltonics Application Note # ET-17 / MT-99 Characterization of the N-glycosylation Pattern of Antibodies by ESI - and MALDI mass spectrometry Abstract Analysis of the N-glycosylation pattern on

More information

Imaging Mass Microscope

Imaging Mass Microscope Imaging Mass Microscope imscope C146-E220 Introducing the New Era of Imaging Mass Spectrometry Imaging mass spectrometry is a revolutionary new technology. The instrument is a combination of an optical

More information

MALDI-TOF analysis of whole blood: its usefulness and potential in the assessment of HbA1c levels

MALDI-TOF analysis of whole blood: its usefulness and potential in the assessment of HbA1c levels MALDI-TOF analysis of whole blood: its usefulness and potential in the assessment of HbA1c levels Jane Y. Yang, David A. Herold Department of Pathology, University of California San Diego, 9500 Gilman

More information

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS LC/MS/MS SOLUTIONS FOR LIPIDOMICS Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS Lipids play a key role in many biological processes, such as the formation of cell membranes and signaling

More information

Edgar Naegele. Abstract

Edgar Naegele. Abstract Simultaneous determination of metabolic stability and identification of buspirone metabolites using multiple column fast LC/TOF mass spectrometry Application ote Edgar aegele Abstract A recent trend in

More information

SCS Mass Spectrometry Laboratory

SCS Mass Spectrometry Laboratory SCS Mass Spectrometry Laboratory Contact Information Staff 31 Noyes Laboratory (8:00-5:00 M-F) 217-333-2545 http://scs.illinois.edu/massspec/ Furong Sun (frs@illinois.edu) Furong Sun Director Training

More information

INTRODUCTION TO MALDI IMAGING

INTRODUCTION TO MALDI IMAGING INTRODUCTION TO MALDI IMAGING Marten F. Snel, Emmanuelle Claude, Thérèse McKenna, and James I. Langridge Waters Corporation, Manchester, UK INT RODUCTION The last few years have seen a rapid increase in

More information

Clinical Microbiology

Clinical Microbiology Clinical Microbiology MALDI Biotyper Fast & Accurate Identification of Microorganisms Innovation with Integrity MALDI-TOF In Microbiology, Every Minute Counts A Powerful Technology for Better Results To

More information

LOCALISATION, IDENTIFICATION AND SEPARATION OF MOLECULES. Gilles Frache Materials Characterization Day October 14 th 2016

LOCALISATION, IDENTIFICATION AND SEPARATION OF MOLECULES. Gilles Frache Materials Characterization Day October 14 th 2016 LOCALISATION, IDENTIFICATION AND SEPARATION OF MOLECULES Gilles Frache Materials Characterization Day October 14 th 2016 1 MOLECULAR ANALYSES Which focus? LOCALIZATION of molecules by Mass Spectrometry

More information

CyBio Felix Your Automated Application Starts Here

CyBio Felix Your Automated Application Starts Here Title Label Lab Automation CyBio Felix Your Automated Application Starts Here 2 CyBio FeliX Future-Proof Liquid Handling Automation Transform your manual workflows to automated processes on your benchtop!

More information

Three Dimensional Mapping and Imaging of Neuropeptides and Lipids in Crustacean Brain

Three Dimensional Mapping and Imaging of Neuropeptides and Lipids in Crustacean Brain Three Dimensional Mapping and Imaging of Neuropeptides and Lipids in Crustacean Brain Using the 4800 MALDI TOF/TOF Analyzer Ruibing Chen and Lingjun Li School of Pharmacy and Department of Chemistry, University

More information

The J105 SIMS. A New Instrument for 3-Dimensional Imaging and Analysis. Paul Blenkinsopp, Ionoptika Ltd

The J105 SIMS. A New Instrument for 3-Dimensional Imaging and Analysis. Paul Blenkinsopp, Ionoptika Ltd The J105 SIMS A New Instrument for 3-Dimensional Imaging and Analysis Paul Blenkinsopp, Ionoptika Ltd The J105 SIMS Why a new ToF Mass Spectrometer? The J105 ToF has been designed to allow us to separate

More information

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions Simplifying Qual/Quan Analysis in Discovery DMPK using UPLC and Xevo TQ MS Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION The determination of the drug metabolism

More information

Components of a Mass Spectrometer

Components of a Mass Spectrometer Components of a Mass Spectrometer Sample Introduction Inlet GC LC Direct Insertion (Syringe/Probe) Ionization Ion Separation Ion Detection Ion Source EI,CI,,, MALDI Mass Analyzer Under vacuum TOF, Quadrupole,

More information

Mass spectrometry is the standard for tracelevel

Mass spectrometry is the standard for tracelevel MALDI-TOF MS as a Label-Free Approach to Rapid Inhibitor Screening Kenneth D. Greis, Songtao Zhou, Thomas M. Burt, Andrew N. Carr, Elizabeth Dolan, Vijayasurian Easwaran, Artem Evdokimov, Richard Kawamoto,

More information

Comprehensive Study of SLE as a Sample. Preparation Tool for Bioanalysis

Comprehensive Study of SLE as a Sample. Preparation Tool for Bioanalysis Comprehensive Study of SLE as a Sample Preparation Tool for Bioanalysis Wan Wang, Warren Chen, Jerry Wang Bonna-Agela Technologies 179 Southern Street, West TEDA, Tianjin, China Abstract A simple, fast,

More information

Supplementary Information

Supplementary Information Supplementary Information Molecular imaging of brain localization of liposomes in mice using MALDI mass spectrometry Annabelle Fülöp 1,2, Denis A. Sammour 1,2, Katrin Erich 1,2, Johanna von Gerichten 4,

More information

Matrix Assisted Laser Desorption Ionization Time-of-flight Mass Spectrometry

Matrix Assisted Laser Desorption Ionization Time-of-flight Mass Spectrometry Matrix Assisted Laser Desorption Ionization Time-of-flight Mass Spectrometry Time-of-Flight Mass Spectrometry. Basic principles An attractive feature of the time-of-flight (TOF) mass spectrometer is its

More information

A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography

A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography Application Note LCMS-109 A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography Time of Flight (LC-TOF) Mass Spectrometry Introduction Many clinical

More information

iplex genotyping IDH1 and IDH2 assays utilized the following primer sets (forward and reverse primers along with extension primers).

iplex genotyping IDH1 and IDH2 assays utilized the following primer sets (forward and reverse primers along with extension primers). Supplementary Materials Supplementary Methods iplex genotyping IDH1 and IDH2 assays utilized the following primer sets (forward and reverse primers along with extension primers). IDH1 R132H and R132L Forward:

More information

Brooke Dilmetz. Quantitation of PFAS using MALDI-TOF MS

Brooke Dilmetz. Quantitation of PFAS using MALDI-TOF MS Brooke Dilmetz Quantitation of PFAS using MALDI-TOF MS Per and polyfluoroalkyl substances PFOS and PFOA manufactured from early 1950 s present 1 Highly persistent and bioaccumulative PFOS (Perfluorooctanesulfonate)

More information

PHOSPHOPEPTIDE ANALYSIS USING IMAC SAMPLE PREPARATION FOLLOWED BY MALDI-MS and MALDI PSD MX

PHOSPHOPEPTIDE ANALYSIS USING IMAC SAMPLE PREPARATION FOLLOWED BY MALDI-MS and MALDI PSD MX PHOSPHOPEPTIDE ANALYSIS USING IMAC SAMPLE PREPARATION FOLLOWED BY MALDI-MS and MALDI PSD MX E. Claude 1, E. Emekwue 2, M. Snel 1, T. McKenna 1 and J. Langridge 1 1: Waters Corporation, Manchester, UK 2:

More information

New Developments in LC-IMS-MS Proteomic Measurements and Informatic Analyses

New Developments in LC-IMS-MS Proteomic Measurements and Informatic Analyses New Developments in LC-IMS-MS Proteomic Measurements and Informatic Analyses Erin Shammel Baker Kristin E. Burnum-Johnson, Xing Zhang, Cameron P. Casey, Yehia M. Ibrahim, Matthew E. Monroe, Tao Liu, Brendan

More information

Mass spectrometry Technologies in Lipid chemistry

Mass spectrometry Technologies in Lipid chemistry Mass spectrometry Technologies in Lipid chemistry Rabah Soliymani University Of Helsinki Protein Chemistry Unit Biomedicum Helsinki Rabah.soliymani@helsinki.fi Complex_&_dynamic_mixtures (few copies to

More information

PesticideScreener. Innovation with Integrity

PesticideScreener. Innovation with Integrity PesticideScreener A complete multi-residue solution for pesticide screening using high resolution full scan accurate mass data Innovation with Integrity LC-MS The Challenge of Ever Increasing Number of

More information

Systematic analysis of protein-detergent complexes applying dynamic light scattering to optimize solutions for crystallization trials

Systematic analysis of protein-detergent complexes applying dynamic light scattering to optimize solutions for crystallization trials Supporting information 1 2 3 Volume 71 (2015) Supporting information for article: 4 5 6 7 8 Systematic analysis of protein-detergent complexes applying dynamic light scattering to optimize solutions for

More information

MALDI-TOF MS: Translating Microbiology Laboratory Alphabet Soup to Optimize Antibiotic Therapy

MALDI-TOF MS: Translating Microbiology Laboratory Alphabet Soup to Optimize Antibiotic Therapy MALDI-TOF MS: Translating Microbiology Laboratory Alphabet Soup to Optimize Antibiotic Therapy September 8, 2017 Amy Carr, PharmD PGY-2 Infectious Diseases Pharmacy Resident Seton Healthcare Family amy.carr@ascension.org

More information

Fundamentals of Soft Ionization and MS Instrumentation

Fundamentals of Soft Ionization and MS Instrumentation Fundamentals of Soft Ionization and MS Instrumentation Ana Varela Coelho varela@itqb.unl.pt Mass Spectrometry Lab Analytical Services Unit Index Mass spectrometers and its components Ionization methods:

More information

Proteomics of body liquids as a source for potential methods for medical diagnostics Prof. Dr. Evgeny Nikolaev

Proteomics of body liquids as a source for potential methods for medical diagnostics Prof. Dr. Evgeny Nikolaev Proteomics of body liquids as a source for potential methods for medical diagnostics Prof. Dr. Evgeny Nikolaev Institute for Biochemical Physics, Rus. Acad. Sci., Moscow, Russia. Institute for Energy Problems

More information

(3) Cyclic Nucleotide Gated (CNG) Assay Technology. (4) Developing uhts CNG Assays on the FLIPR Tetra

(3) Cyclic Nucleotide Gated (CNG) Assay Technology. (4) Developing uhts CNG Assays on the FLIPR Tetra Miniaturized Cyclic Nucleotide-Gated (CNG) Channel Assays to Discover Neuropeptide Y Receptor Modulators Sanjay Saldanha, PhD, HTS/Lead ID Department Slide 1 Presentation Outline (1) Intro to Scripps Florida

More information

Advances in Hybrid Mass Spectrometry

Advances in Hybrid Mass Spectrometry The world leader in serving science Advances in Hybrid Mass Spectrometry ESAC 2008 Claire Dauly Field Marketing Specialist, Proteomics New hybrids instruments LTQ Orbitrap XL with ETD MALDI LTQ Orbitrap

More information

New Instruments and Services

New Instruments and Services New Instruments and Services http://planetorbitrap.com/orbitrap fusion Combining the best of quadrupole, Orbitrap, and ion trap mass analysis in a revolutionary Tribrid architecture, the Orbitrap Fusion

More information

Use of RapidFire/MS for Metabolomics. - from untargeted to targeted and Pathway driven analysis. RapidFire/MS. Moritz Wagner Agilent Technologies

Use of RapidFire/MS for Metabolomics. - from untargeted to targeted and Pathway driven analysis. RapidFire/MS. Moritz Wagner Agilent Technologies Use of RapidFire/MS for Metabolomics RapidFire/MS - from untargeted to targeted and Pathway driven analysis Moritz Wagner Agilent Technologies 1 Agilent RapidFire TM High-throughput Mass Spectrometry System

More information

MALDI Sepsityper Kit

MALDI Sepsityper Kit Instructions for Use MALDI Sepsityper Kit Kit for identification of microorganisms from positive blood cultures using the MALDI Biotyper system CARE products are designed to support our worldwide customers

More information

Solving practical problems. Maria Kuhtinskaja

Solving practical problems. Maria Kuhtinskaja Solving practical problems Maria Kuhtinskaja What does a mass spectrometer do? It measures mass better than any other technique. It can give information about chemical structures. What are mass measurements

More information

Chemical Analysis Business Operations Waters Corporation Milford MA

Chemical Analysis Business Operations Waters Corporation Milford MA The Detection and Identification of Unknown Contaminants During ToF Screening and Structural Elucidation for Pesticides in River Water Using an Integrated Software Approach Chemical Analysis Business Operations

More information

Introduction to Proteomics 1.0

Introduction to Proteomics 1.0 Introduction to Proteomics 1.0 CMSP Workshop Pratik Jagtap Managing Director, CMSP Objectives Why are we here? For participants: Learn basics of MS-based proteomics Learn what s necessary for success using

More information

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations For Research Use Only. Not for use in diagnostic procedures. 1 2015 AB Sciex RUO-MKT-11-1018-A For research

More information

2. Ionization Sources 3. Mass Analyzers 4. Tandem Mass Spectrometry

2. Ionization Sources 3. Mass Analyzers 4. Tandem Mass Spectrometry Dr. Sanjeeva Srivastava 1. Fundamental of Mass Spectrometry Role of MS and basic concepts 2. Ionization Sources 3. Mass Analyzers 4. Tandem Mass Spectrometry 2 1 MS basic concepts Mass spectrometry - technique

More information

Discovery Metabolomics - Quantitative Profiling of the Metabolome using TripleTOF Technology

Discovery Metabolomics - Quantitative Profiling of the Metabolome using TripleTOF Technology ANSWERS FOR SCIENCE. KNOWLEDGE FOR LIFE. Discovery Metabolomics - Quantitative Profiling of the Metabolome using TripleTOF Technology Baljit Ubhi Ph.D ASMS Baltimore, June 2014 What is Metabolomics? Also

More information

Sample Preparation Techniques for Biological Matrices: Finding the right balance to achieve optimal results

Sample Preparation Techniques for Biological Matrices: Finding the right balance to achieve optimal results Sample Preparation Techniques for Biological Matrices: Finding the right balance to achieve optimal results Presenter: Diana Wang Applications Engineer SPP-Support@agilent.com 1 Today s Agenda - Why sample

More information

High-Throughput Analysis of Oligonucleotides using Automated Electrospray Ionization Mass Spectrometry

High-Throughput Analysis of Oligonucleotides using Automated Electrospray Ionization Mass Spectrometry High-Throughput Analysis of Oligonucleotides using Automated Electrospray Ionization Mass Spectrometry Mark E. Hail 1, Brian Elliott 2, Kerry Nugent 3, Jeffrey L. Whitney 1, and David J. Detlefsen 1 1

More information

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS SCIEX QTRAP 4500 LC-MS/MS System and Spark Holland PICO Adrian M. Taylor 1, Peter Ringeling 2, Martin Sibum 2, Stefan Sturm

More information

METABOSCAPE A METABOLITE PROFILING PIPELINE DRIVEN BY AUTOMATIC COMPOUND IDENTIFICATION

METABOSCAPE A METABOLITE PROFILING PIPELINE DRIVEN BY AUTOMATIC COMPOUND IDENTIFICATION METABOSCAPE A METABOLITE PROFILING PIPELINE DRIVEN BY AUTOMATIC COMPOUND IDENTIFICATION OR W TO LINK HRAM QTOF PLANT METABOLOMICS DATA TO BIOLOGY Aiko Barsch, Bruker Daltonics, Bremen, Germany 1 Outline

More information

Mass spectrometry imaging. What does MS imaging offer?

Mass spectrometry imaging. What does MS imaging offer? BMG 744 Mass spectrometry imaging Stephen Barnes, PhD With sincere acknowledgments to David Stella, PhD and Kyle A. Floyd, MS, former students in the Barnes Laboratory (2005 2012) and Kevin Schey, PhD,

More information

Target Analyses in Parallel Reaction Monitoring Mode (PRM)

Target Analyses in Parallel Reaction Monitoring Mode (PRM) Target Analses in Parallel Reaction Monitoring Mode (PRM) Skline Webinar Januar 13, 2015 Bruno Domon, PhD Head Luxembourg Clinical Proteomics Center Invited Professor Universit of Luxembourg INTRODUCTION

More information

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

Mass Spectrometry Made Simple for Clinical Diagnostic Labs Mass Spectrometry Made Simple for Clinical Diagnostic Labs The SCIEX Topaz System with FDA-Cleared Topaz Vitamin D 200M Assay Kit Mass Spectrometry Made Simple SCIEX Topaz System for Clinical Diagnostics

More information

[application note] DIRECT TISSUE IMAGING AND CHARACTERIZATION OF PHOSPHOLIPIDS USING A MALDI SYNAPT HDMS SYSTEM

[application note] DIRECT TISSUE IMAGING AND CHARACTERIZATION OF PHOSPHOLIPIDS USING A MALDI SYNAPT HDMS SYSTEM DIRECT TISSUE IMAGING AND CHARACTERIZATION OF PHOSPHOLIPIDS USING A MALDI SYNAPT HDMS SYSTEM Emmanuelle Claude, Marten Snel, Thérèse McKenna, and James Langridge INTRODUCTION The last decade has seen a

More information

Introduction to the Oligo HTCS Systems. Novatia, LLC

Introduction to the Oligo HTCS Systems. Novatia, LLC Introduction to the Oligo HTCS Systems Novatia, LLC What is the Oligo HTCS and what can it do? Automated ESI/MS system that can analyze up to 14 oligonucleotide samples/day (>3/day with twin autosampler)

More information

Proteomics/Peptidomics

Proteomics/Peptidomics Proteomics/Peptidomics System biology tools and preclinical models for translational research in endometriosis, ESHRE Campus workshop, 4-5 September 2009 E. Waelkens Proteomics: What? Proteins Proteomics

More information

9/11/2017. Disclosures. Imaging Mass Spectrometry. Technical Advances and Clinical Problem Solving. High Mass Resolution Imaging (FTICR MS)

9/11/2017. Disclosures. Imaging Mass Spectrometry. Technical Advances and Clinical Problem Solving. High Mass Resolution Imaging (FTICR MS) Disclosures Academic Affiliation Vanderbilt University School of Medicine MALDI Imaging Mass Spectrometry: Technical Advances and Clinical Problem Solving Industry Affiliations Co-founder & CEO Frontier

More information

Agilent 7700x ICP-MS

Agilent 7700x ICP-MS Agilent 7700x ICP-MS Metals analysis Mid ppt to low ppb detection range Option to detect in four different gas modes to gain optimum detection of multiple metals or interferences in a sample Autosampler

More information

Keeping an Eye on Molecular Imaging: Drug Efficacy & Toxicity in Ophthalmology

Keeping an Eye on Molecular Imaging: Drug Efficacy & Toxicity in Ophthalmology Application Note #MSI-11 Keeping an Eye on Molecular Imaging: Drug Efficacy & Toxicity in Ophthalmology Introduction Mass spectrometry Imaging (MSI) applications for ophthalmic drug discovery have recently

More information

SimGlycan. A high-throughput glycan and glycopeptide data analysis tool for LC-, MALDI-, ESI- Mass Spectrometry workflows.

SimGlycan. A high-throughput glycan and glycopeptide data analysis tool for LC-, MALDI-, ESI- Mass Spectrometry workflows. PREMIER Biosoft SimGlycan A high-throughput glycan and glycopeptide data analysis tool for LC-, MALDI-, ESI- Mass Spectrometry workflows SimGlycan software processes and interprets the MS/MS and higher

More information

SUPPORTING INFORMATION. Multimodal Mass Spectrometry Imaging of N-glycans and Proteins from the Same

SUPPORTING INFORMATION. Multimodal Mass Spectrometry Imaging of N-glycans and Proteins from the Same SUPPORTING INFORMATION Multimodal Mass Spectrometry Imaging of N-glycans and Proteins from the Same Tissue Section. Bram Heijs 1, Stephanie Holst 1, Inge H. Briaire-de Bruijn 2, Gabi W. van Pelt 3, Arnoud

More information

for new contaminants at ultra trace level by using high resolution mass spectrometry

for new contaminants at ultra trace level by using high resolution mass spectrometry Non-targeted screening for new contaminants at ultra trace level by using high resolution mass spectrometry Dr Igor Fochi LSMS Product Specialist Thermo Fisher Scientific What is Environmental Analysis

More information

NON TARGETED SEARCHING FOR FOOD

NON TARGETED SEARCHING FOR FOOD NON TARGETED SEARCHING FOR FOOD CONTAMINANTS USING ORBITRAP HIGH RESOLUTION MASS SPECTROMETRY Michal Godula 1, Adrian Charlton 2 and Klaus Mittendorf 1 1 Thermo Fisher Scientific, Dreieich, Germany 2 Food

More information

Future of Metabolomics. Issues in metabolomics research

Future of Metabolomics. Issues in metabolomics research Knowledge that will change your world Ist UAB Metabolomics Workshop July 22 25, 2013 Future of Metabolomics Stephen Barnes, PhD Director, Targeted Metabolomics and Proteomics Laboratory Issues in metabolomics

More information

GE Healthcare. LOGIQ E9 XDclear 2.0. Complete Ultrasound HEAD TO TOE OBESE TO THIN NEONATE TO GERIATRIC

GE Healthcare. LOGIQ E9 XDclear 2.0. Complete Ultrasound HEAD TO TOE OBESE TO THIN NEONATE TO GERIATRIC GE Healthcare LOGIQ E9 XDclear 2.0 Complete Ultrasound HEAD TO TOE OBESE TO THIN NEONATE TO GERIATRIC In addition to extraordinary image quality, the system has been further enhanced to meet the needs

More information

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates Application Note Clinical Research Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates Authors Limian Zhao and Megan Juck Agilent Technologies, Inc. Abstract

More information

SYNAPT G2-S High Definition MS (HDMS) System

SYNAPT G2-S High Definition MS (HDMS) System SYNAPT G2-S High Definition MS (HDMS) System High performance, versatility, and workflow efficiency of your MS system all play a crucial role in your ability to successfully reach your scientific and business

More information

Bildgebende Massenspektrometrie Erfolgreiche Anwendungen in der biomedizinischen Forschung. Markus Stoeckli

Bildgebende Massenspektrometrie Erfolgreiche Anwendungen in der biomedizinischen Forschung. Markus Stoeckli Bildgebende Massenspektrometrie Erfolgreiche Anwendungen in der biomedizinischen Forschung Markus Stoeckli MALDI Mass Spectrometric Imaging Principle 2 MALDI MSI Markus Stoeckli September 2014 Comparison

More information

SUPPORTING INFORMATION. High Throughput Reaction Screening using Desorption Electrospray Ionization Mass Spectrometry

SUPPORTING INFORMATION. High Throughput Reaction Screening using Desorption Electrospray Ionization Mass Spectrometry Electronic Supplementary Material (ESI) for Chemical Science. This journal is The Royal Society of Chemistry 2018 SUPPORTING INFORMATION High Throughput Reaction Screening using Desorption Electrospray

More information

SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids

SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids Data Independent Acquisition on TripleTOF and X-Series QTOF Systems for Seized Drug Analysis Oscar G. Cabrices

More information

amazon speed Innovation with Integrity Ion Trap Performance Beyond Imagination Ion Trap MS

amazon speed Innovation with Integrity Ion Trap Performance Beyond Imagination Ion Trap MS amazon speed Ion Trap Performance Beyond Imagination Innovation with Integrity Ion Trap MS amazon Turning Speed into Solutions The amazon speed ion trap series sets new analytical standards for proteomics

More information

A systematic investigation of CID Q-TOF-MS/MS collision energies to allow N- and O-glycopeptide identification by LC-MS/MS

A systematic investigation of CID Q-TOF-MS/MS collision energies to allow N- and O-glycopeptide identification by LC-MS/MS A systematic investigation of CID Q-TO-MS/MS collision energies A systematic investigation of CID Q-TO-MS/MS collision energies to allow N- and O-glycopeptide identification by LC-MS/MS Abstract The MS

More information

Mass Spectrometry. Mass spectrometer MALDI-TOF ESI/MS/MS. Basic components. Ionization source Mass analyzer Detector

Mass Spectrometry. Mass spectrometer MALDI-TOF ESI/MS/MS. Basic components. Ionization source Mass analyzer Detector Mass Spectrometry MALDI-TOF ESI/MS/MS Mass spectrometer Basic components Ionization source Mass analyzer Detector 1 Principles of Mass Spectrometry Proteins are separated by mass to charge ratio (limit

More information

MALDI-IMS (MATRIX-ASSISTED LASER DESORPTION/IONIZATION

MALDI-IMS (MATRIX-ASSISTED LASER DESORPTION/IONIZATION MALDI-IMS (MATRIX-ASSISTED LASER DESORPTION/IONIZATION IMAGING MASS SPECTROMETER) IN TISSUE STUDY YANXIAN CHEN MARCH 8 TH, WEDNESDAY. SEMINAR FOCUSING ON What is MALDI imaging mass spectrometer? How does

More information

LC-MS/MS Method for the Determination of Tenofovir from Plasma

LC-MS/MS Method for the Determination of Tenofovir from Plasma LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract

More information

Automated Practical System Qualification, Validation and Reporting acc. ASTM E

Automated Practical System Qualification, Validation and Reporting acc. ASTM E 4th International Symposium on NDT in Aerospace 2012 - Tu.4.A.4 Automated Practical System Qualification, Validation and Reporting acc. ASTM E2737-10 Peter KRAMM *, Malte KURFIß * * YXLON International

More information

The use of random projections for the analysis of mass spectrometry imaging data Palmer, Andrew; Bunch, Josephine; Styles, Iain

The use of random projections for the analysis of mass spectrometry imaging data Palmer, Andrew; Bunch, Josephine; Styles, Iain The use of random projections for the analysis of mass spectrometry imaging data Palmer, Andrew; Bunch, Josephine; Styles, Iain DOI: 10.1007/s13361-014-1024-7 Citation for published version (Harvard):

More information

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification 22 SEPARATION SCIENCE REDEFINED MAY 2005 Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification In the drug discovery process the detection and

More information

GE Healthcare. LOGIQ E9 XDclear 2.0. Complete Ultrasound HEAD TO TOE OBESE TO THIN NEONATE TO GERIATRIC

GE Healthcare. LOGIQ E9 XDclear 2.0. Complete Ultrasound HEAD TO TOE OBESE TO THIN NEONATE TO GERIATRIC GE Healthcare LOGIQ E9 XDclear 2.0 Complete Ultrasound HEAD TO TOE OBESE TO THIN NEONATE TO GERIATRIC Complete Ultrasound HEAD TO TOE OBESE TO THIN NEONATE TO GERIATRIC OUR BEST JUST GOT BETTER. With the

More information

The Agilent MassHunter Software. One Software for all Agilent Mass Spec Systems

The Agilent MassHunter Software. One Software for all Agilent Mass Spec Systems The Agilent MassHunter Software One Software for all Agilent Mass Spec Systems MassHunter The most innovative MS SW! MassHunter Workstation One software for all Agilent MS Systems Minimize learning (and

More information

CHARACTERIZATION AND DETECTION OF OLIVE OIL ADULTERATIONS USING CHEMOMETRICS

CHARACTERIZATION AND DETECTION OF OLIVE OIL ADULTERATIONS USING CHEMOMETRICS CHARACTERIZATION AND DETECTION OF OLIVE OIL ADULTERATIONS USING CHEMOMETRICS Paul Silcock and Diana Uria Waters Corporation, Manchester, UK AIM To demonstrate the use of UPLC -TOF to characterize and detect

More information

Protein and peptides in pictures: Imaging with MALDI mass spectrometry

Protein and peptides in pictures: Imaging with MALDI mass spectrometry Proteomics 2008, 8, 3785 3800 DOI 10.1002/pmic.200800320 3785 REVIEW Protein and peptides in pictures: Imaging with MALDI mass spectrometry Richard J. A. Goodwin 1, Stephen R. Pennington 2 and Andrew R.

More information