Lipididentifizierung in der LC-MS-basierten Lipidomik mittels einer Kombination aus SWATH und DMS
|
|
- Godfrey Manning
- 5 years ago
- Views:
Transcription
1 Lipididentifizierung in der LC-MS-basierten Lipidomik mittels einer Kombination aus SWATH und DMS Michael Witting, et al. Helmholtz Zentrum München Research Unit Analytical BioGeoChemistry Berlin, 14/3/17
2 Lipid identification in LC-MS based lipidomics using a combination of SWATH and DMS Michael Witting, et al. Helmholtz Zentrum München Research Unit Analytical BioGeoChemistry Berlin, 14/3/17
3 Motivation Complexity of the C. elegans lipidome Witting, M, et al. The C. elegans lipidome. Arch Biochem Biophys. 215 Jun 1. pii: S3-9861(15)267-2
4 Motivation Complexity of the C. elegans lipidome
5 Motivation Complexity of the C. elegans lipidome and ways to tackle it Witting, M, et al. The C. elegans lipidome. Arch Biochem Biophys. 215 Jun 1. pii: S3-9861(15)267-2
6 Motivation Complexity of the C. elegans lipidome and ways to tackle it Witting, M, et al. The C. elegans lipidome. Arch Biochem Biophys. 215 Jun 1. pii: S3-9861(15)267-2
7 Lipid identification strategies DDA, DIA and DIA-SWATH DDA DIA DIA-SWATH + - Precursor known - No reconstruction of spectra required - - Coverage problem - Precursor unknown - Reconstruction of spectra required - Large overlap of signals - No coverage problem - Precursor range known - No coverage problem - Exact Precursor mass unknown - Reconstruction of spectra required - Partial overlap of signals - Overlap in DIA causes merged spectra - Merged spectra reduce MS/MS scoring Analysis of single lipid classes in one run Use DMS to clean spectra on the fly Witting, M, et al., LipidFrag: Improving reliability of in silico fragmentation of lipids and application to the Caenorhabditis elegans lipidome,
8 Experimental setup LC conditions UPLC Instrument: Agilent 129 Column: Waters Acquity UPLC HSS T3 Column, 1Å, 1.8 μm, 2.1 mm X 1 mm Mobile phase A: 6:4 Water:ACN with 1 mm NH 4 HCO 2 and.1% formic acid Mobile phase B: 9:1 IPA:ACN with 1 mm NH 4 HCO 2 and.1% formic acid Column Temperature: 5 C Flow rate: 4 ul/min
9 Experimental setup LC conditions TOF Selexion Parameter Value Parameter Value Accumulation Time 1. ms Separation Voltage 4 Curtain Gas 25 Compensation Voltage Varies Gas 1 3 DMS offset -3 Gas 2 5 Ionization Voltage 55 Declustering Potential 8 Source Temperature 6 Start Mass 3 End Mass 1 Resolution enhancement DMS Temperature Modifier Modifier Composition Low Low 1-Propanol Low
10 Development of XCMS workflow Building a SWATH support for XCMS Acquisition with SWATH (one run per COV) Conversion to.ml XCMS for processing (workflow for SWATH required)
11 Development of XCMS workflow Building a SWATH support for XCMS first tests Split data into MS1 and MS2 data Sort MS2 data into different SWATH pockets Perform peak picking on each in individual Select MS1 precursor and search for respective SWATH pocket Find fitting peaks based on RT Get EICs for Precursor and each fragment ion in RT region of precursor Perform correlation analysis Data file MS1 MS2 MS2 MS2 MS1 MS2 MS2 MS2 intensity rt massdiff cor
12 Development of XCMS workflow Spectra reconstruction: TG(12:/12:/12:) (m/z ) 3e+5 Fatty Acyl Substituent Neutral Loss (NL) RCOOH + NH 3 2e : 217 intensity massdiff 14: : 259 1e : : :1 285 e : rt : e+6 18: : : e+6 19: 315 2:5 319 cor.85 2e+6 2: : : : : e
13 Development of XCMS workflow Spectra reconstruction: TG(18:1/18:1/16:) (m/z 876.8) 6 Fatty Acyl Substituent Neutral Loss (NL) RCOOH + NH : 217 intensity massdiff 14: : : : : : rt : e+5 18: : : 31 3e+5 19: :5 319 cor 2e+5 2: : e+5 2: : :6 345 e
14 Development of Workflow with standards TIC of all standards
15 Development of Workflow with standards PC samples fragment m/z 184.7
16 Development of Workflow with standards PC samples fragment m/z V 1.6 V 2.4 V 3.2 V 4. V 4.8 V
17 Development of Workflow with standards C. elegans samples fragment m/z 184.7
18 Development of Workflow with standards C. elegans samples fragment m/z V 1. V 1.8 V 2.6 V 3.4 V 4.2 V
19 What can DMS now add? PC standards 4e+6 3e+6 2 sample PC_SWATH_pos_DMS15-PC variable PC_SWATH_pos_DMS16-PC value 2e+6 PC PC PC intensity PC_SWATH_pos_DMS17-PC PC_SWATH_pos_DMS18-PC PC_SWATH_pos_DMS19-PC PC PC_SWATH_pos_DMS2-PC PC_SWATH_pos_DMS21-PC 1e+6 PC_SWATH_pos_DMS22-PC e Cov rt
20 What can DMS no add? C. elegans samples PC(36:6) 1 3 Area intensity 2 1 sample Pos_LC-DMS-SWATH16 Pos_LC-DMS-SWATH17 Pos_LC-DMS-SWATH18 Pos_LC-DMS-SWATH2 Pos_LC-DMS-SWATH21 Pos_LC-DMS-SWATH22 Pos_LC-DMS-SWATH23 Pos_LC-DMS-SWATH24 Pos_LC-DMS-SWATH26 Pos_LC-DMS-SWATH Cov rt
21 What can DMS no add? C. elegans samples PC(36:6) 3-1 intensity 2 massdiff rt 8e e+5.8 cor 4e+5.6 2e+5.4 e
22 What can DMS no add? C. elegans samples TG(55:6) Fatty Acyl Substituent Neutral Loss (NL) RCOOH + NH : : 245 intensity 2 massdiff -2 15: : : : : rt : : : : : 315 cor.6 5 2: : : : : :6 345
23 Acknowledgment AB Sciex Cyrus Papan Bernd Müller TU München Andreas Dunkel IPB Halle Steffen Neumann BGC, especially Philippe Schmitt-Kopplin
24 Acknowledgment Funding sources
Lipidomic Analysis by UPLC-QTOF MS
Lipidomic Analysis by UPLC-QTOF MS Version: 1 Edited by: Oliver Fiehn Summary Reagents and Materials Protocol Summary:Lipidomic analysis by UPLC-QTOF mass spectrometry Reagents and Materials: Reagent/Material
More informationSelexION Technology for Lipid Analysis: Pushing the Boundaries of Lipidomics
ANSWERS FOR SCIENCE. KNOWLEDGE FOR LIFE. SelexION Technology for Lipid Analysis: Pushing the Boundaries of Lipidomics Baljit Ubhi, Ph.D ASMS Baltimore, June 2014 Lipidomics Profiling Needs and Deliverables
More informationAutomated Lipid Identification Using UPLC/HDMS E in Combination with SimLipid
Automated Lipid Identification Using UPLC/HDMS E in Combination with SimLipid Giorgis Isaac, Stephen McDonald, Giuseppe Astarita Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S
More informationMoving from targeted towards non-targeted approaches
Gesundheitsdirektion Moving from targeted towards non-targeted approaches Anton Kaufmann Official Food Control Authority of the Canton of Zurich () Switzerland 2 Overview I From single residue to multi
More informationNon targeted Lipidomic Analysis by Direct Infusion Mass Spectrometry. Jianzhong Chen, PhD Assistant Professor School of Optometry UAB
Non targeted Lipidomic Analysis by Direct Infusion Mass Spectrometry Jianzhong Chen, PhD Assistant Professor School of Optometry UAB 1 Lipidome: A subset of Metabolome https://en.wikipedia.org/wiki/lipidomics
More informationPhospholipid characterization by a TQ-MS data based identification scheme
P-CN1716E Phospholipid characterization by a TQ-MS data based identification scheme ASMS 2017 MP-406 Tsuyoshi Nakanishi 1, Masaki Yamada 1, Ningombam Sanjib Meitei 2, 3 1 Shimadzu Corporation, Kyoto, Japan,
More informationApplying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis
Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis Ying Qing Yu Waters Corporation, Milford, MA, USA APPLICATION BENEFITS
More informationSupporting Information
Supporting Information Development of a High Coverage Pseudotargeted Lipidomics Method Based on Ultra-High Performance Liquid Chromatography-Mass Spectrometry Qiuhui Xuan 1,2#, Chunxiu Hu 1#, Di Yu 1,2,
More informationA NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS.
A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS. Martin R Green*, Keith Richardson, John Chipperfield, Nick Tomczyk, Martin
More informationLC/MS Method for Comprehensive Analysis of Plasma Lipids
Application Note omics LC/MS Method for Comprehensive Analysis of Plasma s Authors Tomas Cajka and Oliver Fiehn West Coast Metabolomics Center, University of California Davis, 451 Health Sciences Drive,
More informationINTRODUCTION CH 3 CH CH 3 3. C 37 H 48 N 6 O 5 S 2, molecular weight Figure 1. The Xevo QTof MS System.
Fast and Sensitive in vitro Metabolism Study of Rate and Routes of Clearance for Ritonavir using UPLC CUPLED with the Xevo QTof MS System Jose Castro-Perez, Kate Yu, John Shockcor, Henry Shion, Emma Marsden-Edwards,
More informationObtaining Answers to Biological Questions Sample Prep to Data Analysis. Jeremiah D. Tipton, Ph.D. SCIEX Advanced Workflow Specialist in OMICS
Obtaining Answers to Biological Questions Sample Prep to Data Analysis Jeremiah D. Tipton, Ph.D. SCIEX Advanced Workflow Specialist in OMICS OMICS Research Why Quantitative OMICS? 2 2015 AB Sciex SCIEX
More informationImpact of Chromatography on Lipid Profiling of Liver Tissue Extracts
Impact of Chromatography on Lipid Profiling of Liver Tissue Extracts Application Note Clinical Research Authors Mark Sartain and Theodore Sana Agilent Technologies, Inc. Santa Clara, California, USA Introduction
More informationTargeted and untargeted metabolic profiling by incorporating scanning FAIMS into LC-MS. Kayleigh Arthur
Targeted and untargeted metabolic profiling by incorporating scanning FAIMS into LC-MS Kayleigh Arthur K.Arthur@lboro.ac.uk Introduction LC-MS is a highly used technique for untargeted profiling analyses
More informationRapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer
Robert Plumb, Michael D. Jones, and Marian Twohig Waters Corporation, Milford, MA, USA INTRODUCTION The detection and characterization of impurities and degradation products of an active pharmaceutical
More informationIncreasing the Peak Capacity of LC/MS/MS Systems for the Analysis of Complex Biological Samples
Increasing the Peak Capacity of LC/MS/MS Systems for the Analysis of Complex Biological Samples Mark A. McDowall Pharmaceutical Discovery & Life Sciences Waters Corporation, Manchester, UK 2011 Waters
More informationImproving Coverage of the Plasma Lipidome Using Iterative MS/MS Data Acquisition Combined with Lipid Annotator Software and 6546 LC/Q-TOF
Application Note Lipidomics Improving Coverage of the Plasma Lipidome Using Iterative MS/MS Data Acquisition Combined with Lipid Annotator Software and 6546 LC/Q-TOF Authors Jeremy Koelmel Department of
More informationFast Separation of Triacylglycerols in Oils using UltraPerformance Convergence Chromatography (UPC 2 )
Fast Separation of Triacylglycerols in Oils using UltraPerformance Convergence Chromatography (UPC 2 ) Mehdi Ashraf-Khorassani, 1 Larry T. Taylor, 1 Jinchuan Yang, 2 and Giorgis Isaac 2 1 Department of
More informationSWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids
SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids Data Independent Acquisition on TripleTOF and X-Series QTOF Systems for Seized Drug Analysis Oscar G. Cabrices
More informationMass Spectrometry based metabolomics
Mass Spectrometry based metabolomics Metabolomics- A realm of small molecules (
More information[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS
[ APPLICATI TE ] Ion Mobility-enabled Data-dependent Experiments Distinguishing Co-eluting Isomeric Metabolites Using an IMS-QTof Mass Spectrometer Jayne Kirk, 1 Russell Mortishire Smith, 1 Robert Beecher,
More informationMS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager
MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager Quick Start Guide Step 1. Calibrate the Q-TOF LC/MS for low m/z ratios 2 Step 2. Set up a Flow Injection Analysis (FIA) method for
More informationMASS SPECTROMETRY BASED METABOLOMICS. Pavel Aronov. ABRF2010 Metabolomics Research Group March 21, 2010
MASS SPECTROMETRY BASED METABOLOMICS Pavel Aronov ABRF2010 Metabolomics Research Group March 21, 2010 Types of Experiments in Metabolomics targeted non targeted Number of analyzed metabolites is limited
More informationLC-Based Lipidomics Analysis on QTRAP Instruments
LC-Based Lipidomics Analysis on QTRAP Instruments Junhua Wang and Paul RS Baker SCIEX LC-Based Lipidomics Analysis Topics Covered Lipid extraction techniques Hydrophilic Interaction Chromatography (HILIC)
More informationImpurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF
Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF PUSHER TOF DETECTOR ZSPRAY TM Ion Source SAMPLING CONE SKIMMER RF HEXAPOLE RF HEXAPOLE QUADRUPOLE IN NARROW BANDPASS MODE
More informationNew Developments in LC-IMS-MS Proteomic Measurements and Informatic Analyses
New Developments in LC-IMS-MS Proteomic Measurements and Informatic Analyses Erin Shammel Baker Kristin E. Burnum-Johnson, Xing Zhang, Cameron P. Casey, Yehia M. Ibrahim, Matthew E. Monroe, Tao Liu, Brendan
More informationMetabolomic and Lipidomic Research in Diabetes and Obesity 08/07/2013
Novel Tools for omics -based Analysis of Complex Mixtures; Application to a Investigation of the Effect of Prolonged Glucose Stimulation on the Lipid Profile of Mouse Heart Muscle John P. Shockcor, PhD,
More informationNON TARGETED SEARCHING FOR FOOD
NON TARGETED SEARCHING FOR FOOD CONTAMINANTS USING ORBITRAP HIGH RESOLUTION MASS SPECTROMETRY Michal Godula 1, Adrian Charlton 2 and Klaus Mittendorf 1 1 Thermo Fisher Scientific, Dreieich, Germany 2 Food
More information[ APPLICATION NOTE ] High Sensitivity Intact Monoclonal Antibody (mab) HRMS Quantification APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS
Yun Wang Alelyunas, Henry Shion, Mark Wrona Waters Corporation, Milford, MA, USA APPLICATION BENEFITS mab LC-MS method which enables users to achieve highly sensitive bioanalysis of intact trastuzumab
More informationMetabolite identification in metabolomics: Metlin Database and interpretation of MSMS spectra
Metabolite identification in metabolomics: Metlin Database and interpretation of MSMS spectra Jeevan K. Prasain, PhD Department of Pharmacology and Toxicology, UAB jprasain@uab.edu Outline Introduction
More informationRapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition
Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Evelyn Goh Waters Pacific, Singapore APPLICATION BENEFITS This method allows for the simultaneous analysis of 12 water-soluble
More informationLipids Analysis. Lipids
Lipids Analysis Stephen Barnes 3 5 15 Lipids Lipids are mostly very hydrophobic Most are conjugates of fatty acids of a variety of chain lengths, which have different degrees of unsaturation, cis trans
More informationDr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1
Development of an SPE-LC/MS/MS Assay for the Simultaneous Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid in Support of Alzheimer s Research Dr. Erin E. Chambers Waters Corporation Presented
More informationHow to Use TOF and Q-TOF Mass Spectrometers
How to Use TOF and Q-TOF Mass Spectrometers October 2011 What do TOF and Q-TOF offer? TOF Fast scanning of full spectrum High resolution full scan spectra Accurate mass measurements Q-TOF Fast scanning
More informationPTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System
Application Note LC/MS PTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System Purpose This application note describes an automated workflow
More informationProfiling Flavonoid Isomers in Highly Complex Citrus Juice Samples Using UPLC Ion Mobility Time-of-Flight Mass Spectrometry
Profiling Flavonoid Isomers in Highly Complex Citrus Juice Samples Using UPLC Ion Mobility Time-of-Flight Mass Spectrometry Michael McCullagh, 1 Kieran Neeson, 2 and Antonietta Gledhill 1 Waters Corporation,
More informationThe use of mass spectrometry in lipidomics. Outlines
The use of mass spectrometry in lipidomics Jeevan Prasain jprasain@uab.edu 6-2612 utlines Brief introduction to lipidomics Analytical methodology: MS/MS structure elucidation of phospholipids Phospholipid
More informationDiscovery Metabolomics - Quantitative Profiling of the Metabolome using TripleTOF Technology
ANSWERS FOR SCIENCE. KNOWLEDGE FOR LIFE. Discovery Metabolomics - Quantitative Profiling of the Metabolome using TripleTOF Technology Baljit Ubhi Ph.D ASMS Baltimore, June 2014 What is Metabolomics? Also
More informationMetabolite identification in metabolomics: Database and interpretation of MSMS spectra
Metabolite identification in metabolomics: Database and interpretation of MSMS spectra Jeevan K. Prasain, PhD Department of Pharmacology and Toxicology, UAB jprasain@uab.edu utline Introduction Putative
More information4-Fluoroethamphetamine
NMS Labs 2300 Stratford Ave Willow Grove, PA 19090 4-Fluoroethamphetamine Sample Type: Seized Material Latest Revision: January 3, 2019 Date Received: July 31, 2018 Date of Report: January 3, 2019 1. GENERAL
More informationIdentification of Ginsenosides Using the SCIEX X500R QTOF System
Identification of Ginsenosides Using the SCIEX X500R QTOF System Wang Sha, Cheng Haiyan, Liu Ting, Li Lijun, Jin Wenhai[Author] SCIEX, Pacific Applications Support Center (Beijing). China Background Ginseng
More informationAmadeo R. Fernández-Alba
% of compounds % of compounds % of compounds % of compounds Amadeo R. Fernández-Alba LC-Orbitrap QExactive Focus Instrumental LOQ 1% 9% 8% 7% 6% 5% 4% 3% 2% 1% %.1 mg/g.2 mg/g Tomato.5 mg/g ddms2 Target
More informationapplication Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS
application LC/MS Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS Introduction Many kinds of natural colors are used in beverages,
More informationMass-Spectrometric Analysis of Lipids (Lipidomics)
Mass-Spectrometric Analysis of Lipids (Lipidomics) 1. Identification 2. Quantification 3. Metabolism Why to do lipidomics? Biology: Functions of different lipids? Medicine: Diagnostics and Therapy Industry:
More informationO O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions
Simplifying Qual/Quan Analysis in Discovery DMPK using UPLC and Xevo TQ MS Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION The determination of the drug metabolism
More informationMetabolomic fingerprinting of serum samples by direct infusion mass spectrometry
Metabolomic fingerprinting of serum samples by direct infusion mass spectrometry Raúl González-Domínguez * Department of Chemistry, Faculty of Experimental Sciences. University of Huelva, Spain. * Corresponding
More informationfor the Identification of Phosphorylated Peptides
Application of a Data Dependent Neutral-Loss Experiment on the Finnigan LTQ for the Identification of Phosphorylated Peptides Gargi Choudhary Diane Cho Thermo Electron, San Jose, CA Abstracted from posters
More informationChemical Analysis Business Operations Waters Corporation Milford MA
The Detection and Identification of Unknown Contaminants During ToF Screening and Structural Elucidation for Pesticides in River Water Using an Integrated Software Approach Chemical Analysis Business Operations
More informationDevelopment of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid
Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid Joanne ( 乔安妮 ) Mather Senior Scientist Waters Corporation Data courtesy of Erin Chambers and Mary
More informationShotgun Proteomics MS/MS. Protein Mixture. proteolysis. Peptide Mixture. Time. Abundance. Abundance. m/z. Abundance. m/z 2. Abundance.
Abundance Abundance Abundance Abundance Abundance Shotgun Proteomics Protein Mixture 1 2 3 MS/MS proteolysis m/z 2 3 Time µlc m/z MS 1 m/z Peptide Mixture m/z Block Diagram of a Mass Spectrometer Sample
More informationUPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research
Stephen Balloch and Gareth Hammond Waters Corporation, Wilmslow, UK APPLICATION BENEFITS Analytical selectivity afforded by mass selective detection Wide linear measuring range Simple, inexpensive sample
More informationData Independent MALDI Imaging HDMS E for Visualization and Identification of Lipids Directly from a Single Tissue Section
Data Independent MALDI Imaging HDMS E for Visualization and Identification of Lipids Directly from a Single Tissue Section Emmanuelle Claude, Mark Towers, and Kieran Neeson Waters Corporation, Manchester,
More informationLatest Innovations in LC/MS/MS from Waters for Metabolism and Bioanalytical Applications
Latest Innovations in LC/MS/MS from Waters for Metabolism and Bioanalytical Applications Ignatius J. Kass Senior Field Marketing Manager Pharmaceutical MS Challenges in Pharmaceutical Sample Analysis Quantitative
More informationHigh Resolution Glycopeptide Mapping of EPO Using an Agilent AdvanceBio Peptide Mapping Column
High Resolution Glycopeptide Mapping of EPO Using an Agilent AdvanceBio Peptide Mapping Column Application Note BioPharma Authors James Martosella, Phu Duong, and Alex Zhu Agilent Technologies, Inc. Abstract
More informationAB Sciex QStar XL. AIMS Instrumentation & Sample Report Documentation. chemistry
Mass Spectrometry Laboratory AIMS Instrumentation & Sample Report Documentation AB Sciex QStar XL chemistry UNIVERSITY OF TORONTO AIMS Mass Spectrometry Laboratory Department of Chemistry, University of
More informationSUPPORTING INFORMATION:
1S SUPPORTING INFORMATION: The discovery of the once weekly glucagon like peptide 1 (GLP-1) analog semaglutide Jesper Lau*, Paw Bloch, Lauge Schäffer, Ingrid Pettersson, Jane Spetzler, Jacob Kofoed, Kjeld
More informationAccumulation and transformation of inorganic and organic arsenic in rice and role of
Supplementary Information: Accumulation and transformation of inorganic and organic arsenic in rice and role of thiol-complexation to restrict their translocation to shoot Seema Mishra 1,2 *, Jürgen Mattusch
More informationMS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine
Application Note: 346 MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine Gargi Choudhary and Diane Cho, Thermo Fisher Scientific, San Jose, CA Wayne Skinner and
More informationION MOBILITY COUPLED TO HIGH RESOLUTION MASS SPECTROMETRY: THE POSSIBILITIES, THE LIMITATIONS
ION MOBILITY COUPLED TO HIGH RESOLUTION MASS SPECTROMETRY: THE POSSIBILITIES, THE LIMITATIONS Anton Kaufmann Official Food Control Authority of the Canton of Zurich (Kantonales Labor Zürich) Switzerland
More informationIncreased Identification Coverage and Throughput for Complex Lipidomes
Increased Identification Coverage and Throughput for Complex Lipidomes Reiko Kiyonami, David Peake, Yingying Huang, Thermo Fisher Scientific, San Jose, CA USA Application Note 607 Key Words Q Exactive
More informationLipid Class Separation Using UPC 2 /MS
Michael D. Jones, 1,3 Giorgis Isaac, 1 Giuseppe Astarita, 1 Andrew Aubin, 1 John Shockcor, 1 Vladimir Shulaev, 2 Cristina Legido-Quigley, 3 and Norman Smith 3 1 Waters Corporation, Milford, MA, USA 2 Department
More informationRapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS
Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS Mark Ritchie and Evelyn Goh Waters Pacific Pte Ltd., Singapore A P P L I C AT ION B E N E F I T S Delivers a rapid 10-min MRM method
More informationNew Solvent Grade Targeted for Trace Analysis by UHPLC-MS
New Solvent Grade Targeted for Trace Analysis by UHPLC-MS Subhra Bhattacharya, Deva H. Puranam, and Stephen C. Roemer Thermo Fisher Scientific Fisher Chemical, One Reagent Lane, Fair Lawn, NJ Material
More informationJose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford, MA, U.S. and Manchester, UK
HIGH-THRUGHPUT REACTIVE METABLITE SCREEIG FR DICLFEAC BY UPLC AD XEV TQ MS WITH SCAWAVE Jose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford,
More informationMALDI Imaging Drug Imaging Detlev Suckau Head of R&D MALDI Bruker Daltonik GmbH. December 19,
MALDI Imaging Drug Imaging Detlev Suckau Head of R&D MALDI Bruker Daltonik GmbH December 19, 2014 1 The principle of MALDI imaging Spatially resolved mass spectra are recorded Each mass signal represents
More informationLC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS
LC/MS/MS SOLUTIONS FOR LIPIDOMICS Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS Lipids play a key role in many biological processes, such as the formation of cell membranes and signaling
More informationIdentification & Confirmation of Structurally Related Degradation Products of Simvastatin
Identification & Confirmation of Structurally Related Degradation Products of Simvastatin Power of QTRAP Systems for Identification and Confirmation of Degradation Products Dilip Reddy 1, Chandra Sekar
More informationQuantitation of Sphingolipids in Tissue Extracts by LC/MS/MS
Quantitation of Sphingolipids in Tissue Extracts by LC/MS/MS Alexei Belenky CASSS, Meritage Resort, Napa 2008 Outline Role of lipid analysis in drug discovery and disease diagnostics Analytical tools and
More informationHigh resolution mass spectrometry for bioanalysis at Janssen. Current experiences and future perspectives
High resolution mass spectrometry for bioanalysis at Janssen. Current experiences and future perspectives Lieve Dillen Drug Safety Sciences Analytical Sciences, Non-regulated Bioanalysis Presentation outline
More informationChoosing the metabolomics platform
Choosing the metabolomics platform Stephen Barnes, PhD Department of Pharmacology & Toxicology University of Alabama at Birmingham sbarnes@uab.edu Challenges Unlike DNA, RNA and proteins, the metabolome
More informationDon t miss a thing on your peptide mapping journey How to get full coverage peptide maps using high resolution accurate mass spectrometry
Don t miss a thing on your peptide mapping journey How to get full coverage peptide maps using high resolution accurate mass spectrometry Kai Scheffler, PhD BioPharma Support Expert,LSMS Europe The world
More informationSue D Antonio Application Chemist Cedar Creek, TX
Sue D Antonio Application Chemist Cedar Creek, TX What is Hemp Oil? CBD hemp oil is a natural botanical extract of the common hemp plant. CBD hemp oil is derived from the seeds and stem of the Cannabis
More informationSupporting information
Supporting information A novel lipidomics workflow for improved human plasma identification and quantification using RPLC-MSn methods and isotope dilution strategies Evelyn Rampler 1,2,3, Angela Criscuolo
More informationSupplementary Information
Supplementary Information Molecular imaging of brain localization of liposomes in mice using MALDI mass spectrometry Annabelle Fülöp 1,2, Denis A. Sammour 1,2, Katrin Erich 1,2, Johanna von Gerichten 4,
More informationA UPLC/MS Approach for the Diagnosis of Inborn Errors of Metabolism
Elizabeth Want, 1 Stephen McDonald 2 1 Imperial College, London, UK 2 Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S UPLC /MS E was used to profile diagnostic metabolites in a
More informationSimple Method (IS-MRM) to Monitor Lysophospholipids and Phospholipids During LC-MS Method Development via In-Source CID
Simple Method (IS-MRM) to Monitor Lysophospholipids and Phospholipids During LC-MS Method Development via In-Source CID James Little, Eastman Chemical Company, Kingsport, TN Overview Phospholipids and
More informationPosterREPRINT RAPID, SELECTIVE SCREENING OF URINE SAMPLES FOR GLUCURONIDES BY LC/MS/MS INTRODUCTION ABSTRACT
ABSTRACT The traditional study of in vivo drug metabolism in plasma or urine samples is often complicated by the presence of many endogenous compounds. Several mass spectrometric techniques are often applied
More informationAgilent 6470 Triple Quadrupole LC/MS System and EMR-Lipid. The Combination for Confident Pesticide Quantitation. Christoph Mueller
Agilent 670 Triple Quadrupole LC/MS System and EMR-Lipid The Combination for Confident Pesticide Quantitation Christoph Mueller Agilent Technologies LCMS Application Scientist EMEAI Food Market Program
More information[application note] DIRECT TISSUE IMAGING AND CHARACTERIZATION OF PHOSPHOLIPIDS USING A MALDI SYNAPT HDMS SYSTEM
DIRECT TISSUE IMAGING AND CHARACTERIZATION OF PHOSPHOLIPIDS USING A MALDI SYNAPT HDMS SYSTEM Emmanuelle Claude, Marten Snel, Thérèse McKenna, and James Langridge INTRODUCTION The last decade has seen a
More informationRelative Quantitation of Human Polymorphonuclear Leukocyte Cell Membrane GPEtn Lipids
Relative Quantitation of Human Polymorphonuclear Leukocyte Cell Membrane GPEtn Lipids Using the QTRAP System with mtraq Reagents Karin A. Zemski-Berry 1, John M. Hevko 2, and Robert C. Murphy 1 1 Department
More informationDetermination of Chlorophenoxyacetic Acid and Other Acidic Herbicides Using a QuEChERS Sample Preparation Approach and LC-MS/MS Analysis
Determination of Chlorophenoxyacetic Acid and Other Acidic Herbicides Using a QuEChERS Sample Preparation Approach and LC-MS/MS Analysis UCT Product Number: ECQUEU75CT-MP - Mylar pouch containing extraction
More informationUsing Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.
Using Software Tools to Improve the Detection of Impurities Application Note Christine Miller Introduction The analysis of raw materials and finished products for or impurities presents a challenge in
More informationLC-MS. Pre-processing (xcms) W4M Core Team. 29/05/2017 v 1.0.0
LC-MS Pre-processing (xcms) W4M Core Team 29/05/2017 v 1.0.0 Acquisition files upload and pre-processing with xcms: extraction, alignment and retention time drift correction. SECTION 1 2 LC-MS Data What
More informationDirect Analysis of Folic Acid in Digestive Juices by LC/TOF-MS Application
Direct Analysis of Folic Acid in Digestive Juices by LC/TOF-MS Application Food Safety Authors M. H. Blokland, P. W. Zoontjes, S. S. Sterk, and L. A. van Ginkel, National Institute of Public Health and
More informationIdentification of Imidacloprid Metabolites in Onions Using High Resolution Accurate Mass Spectrometry (LC/Q-TOF MS) and Accurate Mass Tools
Identification of Imidacloprid Metabolites in Onions Using High Resolution Accurate Mass Spectrometry (LC/Q-TOF MS) and Accurate Mass Tools Application ote Food Authors E. Michael Thurman and Imma Ferrer
More informationA Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids
A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids Jeremy Netto, 1 Stephen Wong, 1 Federico Torta, 2 Pradeep Narayanaswamy, 2
More informationANALYTICAL REPORT 1 3C-P (C14H23NO3) 1-(3,5-dimethoxy-4-propoxylphenyl)propan-2-amine.
Vodovodna 95, 1000 LJUBLJANA, SLOVENIA T: +386 (0)1 428 44 93 E: nfl@policija.si www.policija.si Remark other NPS detected: none ANALYTICAL REPORT 1 3C-P (C14H23NO3) 1-(3,5-dimethoxy-4-propoxylphenyl)propan-2-amine
More informationSunil Kulkarni Product Specialist Agilent Technologies
Drug Residue Analysis by LC/MS methods Sunil Kulkarni Product Specialist Agilent Technologies Outline General Drug Residue information Veterinary drug residue Analysis by LC/MS QQQ and Q-TOF method Analytical
More informationAnalysis of several common. organic acids in tobacco leaf, snus, and moist snuff
Analysis of several common organic acids in tobacco leaf, snus, and moist snuff S. C. Moldoveanu, W. A. Scott R.J. Reynolds Tobacco Co. Background Among the organic acids commonly present in tobacco, are
More informationAnalysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research
Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research Dominic Foley, Michelle Wills, and Lisa Calton Waters Corporation, Wilmslow, UK APPLICATION
More informationProfiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography
Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography Application Note Metabolomics Author Yuqin Dai Agilent Technologies, Inc. 31 Stevens Creek Blvd,
More informationAdvancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations
Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations For Research Use Only. Not for use in diagnostic procedures. 1 2015 AB Sciex RUO-MKT-11-1018-A For research
More informationUPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes
UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes Catalin E. Doneanu, Weibin Chen, and Jeffrey R. Mazzeo Waters Corporation, Milford, MA, U.S. A P P L I C AT ION B E N E F
More informationInternational Journal of Applied Pharmaceutical Sciences and Research
International Journal of Applied Pharmaceutical Sciences and Research 2017; 2(3): 55-63 Anas et al/international Journal of Applied Pharmaceutical Sciences and Research 2017; 2(3): 55-63 International
More informationMethod Development for the Analysis of Endogenous Steroids Using Convergence Chromatography with Mass Spectrometric Detection
Method Development for the Analysis of Endogenous Steroids Using Convergence Chromatography with Mass Spectrometric Detection Christopher J. Hudalla, Stuart Chadwick, Fiona Liddicoat, Andrew Peck, and
More informationMetabolomic and Proteomics Solutions for Integrated Biology. Christine Miller Omics Market Manager ASMS 2015
Metabolomic and Proteomics Solutions for Integrated Biology Christine Miller Omics Market Manager ASMS 2015 Integrating Biological Analysis Using Pathways Protein A R HO R Protein B Protein X Identifies
More informationQSTAR Operation. May 3, Bob Seward
QSTAR Operation May 3, 2005 Bob Seward Presentation CD Contents QSTAR Hardware QSTAR Schematic 10-7 torr QSTAR Schematic Chernushevich et al, JMS 2001, 36: 849-865 Curtain Plate ESI Source ESI Source Curtain
More informationSEPARATION OF BRANCHED PFOS ISOMERS BY UPLC WITH MS/MS DETECTION
SEPARATION OF BRANCHED PFOS ISOMERS BY UPLC WITH MS/MS DETECTION Marian Twohig 1, Nicholas Ellor 1, Keith Worrall 2, Tim Jenkins 2, Gordon Kearney 2 1 Waters Corporation, 1 Cummings Center, Beverly, MA
More informationA Metabolomics Approach to Profile Novel Chemical Markers for Identification and Authentification of Terminalia Species
A Metabolomics Approach to Profile Novel Chemical Markers for Identification and Authentification of Terminalia Species Bharathi Avula, 1 Kate Yu, 2 Yan-Hong Wang, 1 Jordan Blodgett, 2 Alan Millar, 2 and
More informationANALYTICAL REPORT 1 DPT (C16H24N2) [2-(1H-indol-3-yl)ethyl]dipropylamine.
Vodovodna 95 1000 Ljubljana SLOVENIJA T: +386 (0)1 428 44 93 E: nfl@policija.si www.policija.si Remark other NPS detected: none ANALYTICAL REPORT 1 DPT (C16H24N2) [2-(1H-indol-3-yl)ethyl]dipropylamine
More information