Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-09 FEATURES

Size: px
Start display at page:

Download "Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-09 FEATURES"

Transcription

1 AVAILABLE SIZES: CERTIFICATION: Nominal sizes available from 018 through 060 to meet the needs of residential and light commercial applications. All models are listed with UL, (U.S. and Canada), ARI, and CEC. ELECTRICAL RANGE: Units are offered in v, single phase 018 through 060 sizes; 208/230v, three phase in 036, 048 and 060 sizes; and 460v, three phase in 060 size. FAN MOTOR: CABINET: The totally enclosed fan motor provides greater reliability under adverse conditions and dependable performance for many years. The permanent split capacitor type motor was designed for optimum efficiency. The motor was then qualified under extreme conditions to help ensure a long, reliable life. A weather protective cabinet of steel is protected with a galvanized coating and treated with a layer of zinc phosphate. A coat of modified polyester powder coating is then applied and baked on, providing each unit with a hard, smooth finish that will last for many years. All screws on cabinet exterior are coated for a long-lasting, rustresistant, quality appearance. FEATURES UNIT DESIGN: COMPRESSOR: SERVICE VALVES: SERVICEABILITY: The copper tube, enhanced sine wave, aluminum fin coil is designed for optimum heat transfer. Vertical air discharge carries sound and hot condenser air up and away from adjacent patio areas and foliage. The base pan is designed for easy removal of water, dirt, and leaves. Each compressor is protected with internal temperature- and current-sensitive overloads. An internal pressure relief valve provides high-pressure protection to the refrigerant system. For improved serviceability, all models are equipped with a compressor terminal plug. Both service valves are brass, front seating type with sweat connections. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures. One panel provides access to electrical controls. Removal of top gives access to fan motor, compressor, and condenser coil. Model PA10 ELECTRIC CONDITIONER SS-PA10-09

2 NOTES: 1. Allow 30 in. clearance to service side of unit, 48 in. above unit, 6 in. on one side, 12 in. on remaining side, and 24 in. between units for proper airflow. 2. Minimum outdoor operating ambient in cooling mode is 55 F max 125 F. 3. Series designation is the 14th position of the unit model number. 4. Center of gravity. A 3/ 8 IN. DIA TIEDOWN KNOCKOUTS (2) PLACES IN IN DISCHARGE IN DISCHARGE DISCHARGE FIELD POWER SUPPLY CONN 7 / 8 IN. DIA HOLE WITH 1 1 / 8 IN. DIA KNOCKOUT AND 1 3 / 8 IN. DIA KNOCKOUT FIELD CONTROL SUPPLY CONN 7 / 8 IN. DIA HOLE B J N P 3 / 8 IN. DIA LIQUID LINE CONN DISCHARGE IN 2 7 / 8 C E M F D DIA VAPOR LINE CONN 1 1 / 4 A937 DIMENSIONS (IN.) UNIT SIZE SERIES A B C D E F J M N P NOTE: The data in this publication is displayed for all series, however, every series may not be available from manufacturer. SHIPPING WEIGHT (Lb) 018 C 22-1/ /16 3-3/16 5/8 18-1/2 4-1/16 8-3/ /8 12-1/4 9-3/ C 22-1/ /16 3-3/16 5/8 18-1/2 4-1/16 8-3/ /8 12-1/4 10-3/ C 22-1/ /16 3-3/16 3/4 18-1/2 4-1/16 8-3/ /8 12-1/4 11-1/ B 22-1/ /16 3-3/16 3/4 18-1/2 4-1/16 8-3/ /8 12-1/4 11-3/ C 22-1/ /16 3-3/16 3/4 18-1/2 4-1/16 8-3/ /8 12-1/4 11-3/ C, D 22-1/ /16 3-1/4 7/8 18-1/2 4-1/16 8-3/ /8 12-1/4 11-3/ C 22-1/ /16 3-1/4 7/8 18-1/2 4-1/16 8-3/ /8 12-1/ C 22-1/ /16 3-1/4 7/8 18-1/2 4-1/16 8-3/ /8 12-1/ D 22-1/ /16 3-1/4 7/8 18-1/2 4-1/16 8-3/ /8 12-1/4 15-1/ C /16 3-1/4 7/8 23-1/2 6-1/ / UNITARY CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 REGISTERED QUALITY SYSTEM SOUND POWER (A-wtd., non-pure tone corrected.) NOTE: Tested in accordance with ARI standard (Not listed with ARI.) 2 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. UNIT SOUND OCTAVE BAND CENTER FREQUENCY (Hz) SIZE LEVEL C C C B C C D C C D C

3 See notes on page 5. METERING DEVICE PISTON* UNIT SIZE-SERIES IDENTIFICATION NO. 018-C C C B C C D C C, D C 93 * Piston listed is for any approved coil non-capillary tube combination. Piston is shipped with outdoor unit and must be installed in an approved indoor coil. SPECIFICATIONS UNIT SIZE SERIES C C C ELECTRICAL Unit Volts Hertz Phase Operating Voltage Range* Compressor Rated Load Amps Locked Rotor Amps Condenser Fan Motor Full Load Amps Min Unit Ampacity for Wire Sizing Min Wire Size (60 C/75 F Copper) AWG 14/14 14/14 14/14 Max Wire Length (60 C/75 F) (Ft) 66/ 53/50 39/37 Max Branch Circuit Fuse Size** COMPRESSOR & REFRIGERANT Compressor Type Reciprocating Temperature and Current Protection Internal Line Break Refrigerant Type and Amount (Lbs) R R R Refrigerant Tubes (In. OD) Vapor and Liquid (Up to 50 Ft) 5/8 and 3/8 3/4 and 3/8 CONDENSER COIL & FAN Coil Face Area (Sq Ft) Fan Motor HP, Type, and RPM 1/12 PSC and /10 PSC and 1125 Volts Hertz Phase 208/ Condenser Airflow (CFM) OPTIONAL EQUIPMENT Cycle Protector KSACY0101AAA Start Assist PTC Type KAACS0201PTC Start Assist Capacitor/Relay Type KSAHS0901AAA Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Time-Delay Relay KAATD0101TDR Winter Start Control KAAWS0101AAA Evaporator Freeze Thermostat KAAFT0101AAA Crankcase Heater KAACH1001AAA Liquid Line Solenoid Valve KAALS0101LLS Filter Drier P S Coastal Filter KAACF0401MED TXV Kit (RPB) KAATX0201RPB KAATX0301RPB KAATX0401RPB TXV (Hard Shutoff) KSATX0601HSO Thermostat, Manual Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATPPBAC01-B Thermostat, Manual Changeover, 5-2-Day Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATPPSAC01-B Backplate for Standard Thermostat TSTATXXBBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Outdoor Air Temperature Sensor TSTATXXSEN01-B MotorMaster Control 32LT Ball Bearing Fan Motor HC34GE232 3

4 SPECIFICATIONS Continued UNIT SIZE SERIES C B C/D C ELECTRICAL Unit Volts Hertz Phase / Operating Voltage Range* Compressor Rated Load Amps / Locked Rotor Amps / Condenser Fan Motor Full Load Amps 1.4 Min Unit Ampacity for Wire Sizing / Min Wire Size (60 C/75 F Copper) AWG 12/12 14/14 10/10 Max Wire Length (60 C/75 F) (Ft) 57/54 65/ 67/63 Max Branch Circuit Fuse Size** COMPRESSOR & REFRIGERANT Compressor Type Reciprocating Scroll/Recip Scroll Temperature and Current Protection Internal Line Break Refrigerant Type and Amount (Lbs) R R R R Refrigerant Tubes (In. OD) Vapor and Liquid (Up to 50 Ft) 3/4 and 3/8 7/8 and 3/8 CONDENSER COIL & FAN Coil Face Area (Sq Ft) Fan Motor HP, Type, and RPM 1/4 PSC and 1125 Volts Hertz Phase 208/ Condenser Airflow (CFM) 2500 OPTIONAL EQUIPMENT Cycle Protector KSACY0101AAA Start Assist PTC Type KAACS0201PTC Start Assist Capacitor/Relay Type KSAHS1901AAA N/A KSAHS1501AAA/ KSAHS2201AAA KSAHS1601AAA Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Time-Delay Relay KAATD0101TDR Winter Start Control KAAWS0101AAA Evaporator Freeze Thermostat KAAFT0101AAA Crankcase Heater KAACH1001AAA KAACH1201AAA/ KAACH1001AAA KAACH1201AAA Liquid Line Solenoid Valve KAALS0101LLS Filter Drier P S P S Coastal Filter KAACF0401MED TXV Kit (RPB) KAATX0501RPB KAATX0601RPB TXV (Hard Shutoff) KSATX0601 HSO KSATX0701HSO Thermostat, Manual Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATPPBAC01-B Thermostat, Manual Changeover, 5-2-Day Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATPPSAC01-B Backplate for Standard Thermostat TSTATXXBBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Outdoor Air Temperature Sensor TSTATXXSEN01-B MotorMaster Control 32LT Ball Bearing Fan Motor HC40GE232 See notes on page 5. 4

5 SPECIFICATIONS Continued UNIT SIZE SERIES C/D C/D C C C ELECTRICAL Unit Volts Hertz Phase / / Operating Voltage Range* Compressor Rated Load Amps 24.4/ / Locked Rotor Amps 140.0/ / Condenser Fan Motor Full Load Amps Min Unit Ampacity for Wire Sizing 31.9/ / Min Wire Size (60 C/75 F Copper) AWG 8/10 14/14 8/8 12/12 14/14 Max Wire Length (60 C/75 F) (Ft) 97/59 48/46 82/78 58/55 152/144 Max Branch Circuit Fuse Size** COMPRESSOR & REFRIGERANT Compressor Type Scroll Temperature and Current Protection Internal Line Break Refrigerant Type and Amount (Lbs) R /6.10 R Refrigerant Tubes (In. OD) Vapor and Liquid (Up to 50 Ft) 7/8 and 3/8 1-1/8 and 3/8 CONDENSER COIL & FAN Coil Face Area (Sq Ft) 9.45/ Fan Motor HP, Type, and RPM 1/4 PSC and 1125 Volts Hertz Phase Condenser Airflow (CFM) OPTIONAL EQUIPMENT Cycle Protector KSACY0101AAA Start Assist PTC KAACS0201PTC N/A KAACS0201PTC N/A Start Assist Capacitor/RelayType KSAHS1601AAA/ KSAHS1501AAA N/A KSAHS1601AAA N/A Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Time-Delay Relay KAATD0101TDR Winter Start Control KAAWS0101AAA Evaporator Freeze Thermostat KAAFT0101AAA Crankcase Heater KAACH1201AAA KAACH1301AAA Liquid Line Solenoid Valve KAALS0101LLS Filter Drier P S Coastal Filter KAACF0401MED KAACF0501LRG TXV Kit (RPB) KAATX0601RPB KAATX0701RPB TXV Hard Shutoff KSATX0701HSO Thermostat, Manual Changeover, Non-Programmable, F/ C, 1 Stage Heat, 1 Stage Cool TSTATPPBAC01-B Thermostat, Manual Changeover, 5-2-Day Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATPPSAC01-B Backplate for Standard Thermostat TSTATXXBBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Outdoor Air Temperature Sensor TSTATXXSEN01-B MotorMaster Control 32LT LT Ball Bearing Fan Motor HC40GE232 HC40GE4 * Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure. If wire is applied at ambient greater than 30 C (86 F), consult Table of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60 C (140 F) conductors, per the NEC (ANSI/NFPA 70) Article Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time-delay fuse or circuit breaker. Start assist capacitor and relay required when using liquid solenoid valve or hard shutoff TXV (except 048 and 060 Sizes). Do not use hard shutoff TXV with liquid solenoid valve. Furnace model numbers P08UA, P08LA, and PG8HA are not compatible with this thermostat. N/A Not applicable in this application. NOTES: 1. Control circuit is 24v on all units and requires external power source. 2. All motors/compressors contain internal overload protection. 3. Copper wire must be used from service disconnect to unit. 5

6 ACCESSORY USAGE GUIDELINE ACCESSORY REQUIRED FOR LOW-AMBIENT APPLICATIONS (Below 55 F) REQUIRED FOR LONG-LINE APPLICATIONS* (Over 50 Ft) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 Miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Winter Start Control Yes No No Accumulator No No No Compressor Start Assist Capacitor and Relay Yes Yes No MotorMaster Control Yes No No Wind Baffle See low-ambient instructions No No Coastal Filter No No Yes Support Feet Recommended No Recommended Liquid-Line Solenoid Valve or Hard Shutoff TXV No See Long-Line Application Guideline Ball Bearing Fan Motor Yes No No * For tubing line sets between 50 and 175 ft and/or 20 ft vertical differential, refer to Residential s Split s Long-Line Application Guidelines. Only when low-pressure switch is used. No ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) 1. Ball Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. SUGGESTED USE: Required on all units where Low-Ambient kit (full modulation feature) or MotorMaster Control has been added. 2. Coastal Filter A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow. SUGGESTED USE: In geographic areas where salt damage could occur. 3. Compressor Start Assist Capacitor/Relay Type Start capacitor and start relay gives hard boost to compressor motor at each start-up. SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft. Installations where outdoor design temperature exceeds 105 F (40.6 C). Replacement installations with hard shutoff expansion valve on indoor coil. 4. Compressor Start Assist PTC Type Solid-state electrical device which gives a soft boost to the compressor at each start-up. SUGGESTED USE: Installations with marginal power supply. Replacement installations with rapid pressure balance (RPB) expansion valve on indoor coil. 5. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control. SUGGESTED USE: When interconnecting tube length exceeds 50 ft. When unit will be operated below 55 F (12.8 C) outdoor air temperature. Use with low-ambient controller. All commercial installations. 6. Cycle Protector Solid-state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including normal room thermostat cycling. SUGGESTED USE: Installations in areas where power interruptions are frequent. Where user is likely to play with the room thermostat. All commercial installations. Installations where interconnecting tube length exceeds 50 ft. High-rise applications. 7. Evaporator Freeze Thermostat An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions. SUGGESTED USE: All units where winter start control has been added. 8. High-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to about 400 psig. Provides additional protection against compressor damage due to loss of outdoor airflow. To prevent rapid compressor recycling, cycle protector can be used with this switch. SUGGESTED USE: Installations exposed to very dirty outdoor air. Installations where condenser inlet air temperature exceeds 125 F (51.7 C). 9. Liquid Solenoid Valve (LSV) An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration) and which stops and starts refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle. Note: Compressor start assist capacitor/relay type must also be used. SUGGESTED USE: For improved system performance in air conditioners for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. In certain long line applications. (Refer to Long-Line Application Guideline.) 6

7 ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued 10. Low-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on low side of refrigerant circuit. Cycles compressor off if refrigerant pressure drops to about 27 psig. Prevents indoor coil freeze-up due to loss of indoor airflow. Also, provides additional protection against compressor damage due to loss of refrigerant charge. To prevent rapid compressor recycling. Cycle protector can be used with this switch. SUGGESTED USE: Where indoor coil is exposed to dirty air. All commercial installations. 11. MotorMaster Control A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to 20 F, it maintains condensing temperature at 100 F ± 10 F. SUGGESTED USE: operation at outdoor temperatures below 55 F. All commercial installations. 12. Sound Hood Wraparound sound attenuation cover for the compressor. Reduces unit sound level by about 2dBA. SUGGESTED USE: Unit installed closer than 15 ft to quiet areas bedrooms, etc. Unit installed between 2 houses less than 10 ft apart. 13. Thermostatic Expansion Valve (TXV) Kits A modulating flow control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shutoff and RPB type valves are available. SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. 14. Time-Delay Relay An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off. SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. 15. Winter Start Control An SPST delay relay which bypasses the low-pressure switch for approximately 3 minutes to permit start-up for cooling operation under low-load conditions. SUGGESTED USE: All air conditioners where low-ambient controller has been added. 7

8 RATINGS AND PERFORMANCE UNIT SIZE-SERIES 018-C 024-C 030-C 036-B (3 Phase) 036-C (1 Phase) See notes on page 10. INDOOR MODEL TOT. CAP. BTUH FACTORY SUPPLIED ENHANCE- MENT STANDARD RATING SEER PAYNE GAS FURNACE OR ACCESSORY TDR ACCESSORY TXV *CC5A/CD5AA018 17,200 NONE CC5A/CD5AA024 17,400 NONE CC5A/CD5AW024 17,400 NONE CE3AA024 17,400 NONE CF5AA024 17,400 NONE CK3BA024 17,400 NONE CK5A/CK5BA018 17,200 NONE CK5A/CK5BA024 17,400 NONE CK5A/CK5BW024 17,400 NONE FF1DNA018 17,200 TDR FF1DNA024 17,400 TDR FF1DNE018 17,200 TDR&TXV FF1DNE024 17,400 TDR&TXV PF1MNA018 17,200 TDR PF1MNA024 17,400 TDR PF1MNB018 17,200 TDR PF1MNB024 17,400 TDR *CC5A/CD5AA024 22,000 NONE CC5A/CD5AA030 22,400 NONE CC5A/CD5AW024 22,000 NONE CC5A/CD5AW030 22,400 NONE CE3AA024 22,000 NONE CE3AA030 22,400 NONE CF5AA024 22,000 NONE CK3BA024 22,000 NONE CK3BA030 22,400 NONE CK5A/CK5BA024 22,000 NONE CK5A/CK5BA030 22,400 NONE CK5A/CK5BW024 22,000 NONE CK5A/CK5BW030 22,400 NONE FF1DNA024 22,200 TDR FF1DNA030 22,800 TDR FF1DNE024 22,200 TDR&TXV FF1DNE030 22,800 TDR&TXV PF1MNA024 22,200 TDR PF1MNA030 22,400 TDR PF1MNB024 22,200 TDR PF1MNB030 22,400 TDR *CC5A/CD5AA030 27,600 NONE CC5A/CD5AA036 28,400 NONE CC5A/CD5AW030 27,600 NONE CC5A/CD5AW036 28,400 NONE CE3AA030 27,600 NONE CE3AA036 28,400 NONE CF5AA036 28,400 NONE CK3BA030 27,600 NONE CK3BA036 28,400 NONE CK5A/CK5BA030 27,600 NONE CK5A/CK5BA036 28,400 NONE CK5A/CK5BT036 28,400 NONE CK5A/CK5BW030 27,600 NONE CK5A/CK5BW036 28,400 NONE FF1DNA030 27,600 TDR FF1DNE030 27,600 TDR&TXV PF1MNA030 27,600 TDR PF1MNA036 28,400 TDR PF1MNB030 27,600 TDR PF1MNB036 28,400 TDR *CC5A/CD5AA036 33,800 NONE CC5A/CD5AA042 33,800 NONE CC5A/CD5AW036 33,800 NONE CE3AA036 33,400 NONE CE3AA042 33,600 NONE CF5AA036 33,600 NONE CK3BA036 33,800 NONE CK3BA042 33,800 NONE CK5A/CK5BA036 33,800 NONE CK5A/CK5BA042 33,800 NONE CK5A/CK5BT036 33,800 NONE CK5A/CK5BT042 33,800 NONE CK5A/CK5BW036 33,800 NONE *CC5A/CD5AA036 33,800 NONE CC5A/CD5AA042 33,800 NONE CC5A/CD5AW036 33,800 NONE CC5A/CD5AW042 33,800 NONE CE3AA036 33,400 NONE CE3AA042 33,600 NONE CF5AA036 33,600 NONE CK3BA036 33,800 NONE CK3BA042 33,800 NONE CK5A/CK5BA036 33,800 NONE CK5A/CK5BA042 33,800 NONE CK5A/CK5BT036 33,800 NONE CK5A/CK5BT042 33,800 NONE CK5A/CK5BW036 33,800 NONE EER 8

9 RATINGS AND PERFORMANCE Continued UNIT SIZE-SERIES 036-C (1 Phase) 042-C, D 047-C 048-C, D (1 & 3 Phase) 060-C (1 & 3 Phase) See notes on page 10. INDOOR MODEL TOT. CAP. BTUH FACTORY SUPPLIED ENHANCE- MENT STANDARD RATING SEER PAYNE GAS FURNACE OR ACCESSORY TDR ACCESSORY TXV PF1MNA036 33,200 TDR PF1MNA042 33,800 TDR PF1MNA071 35,000 TDR&TXV PF1MNB036 33,200 TDR PF1MNB042 33,800 TDR PF1MNB071 35,000 TDR&TXV *CC5A/CD5AA042 40,000 NONE CC5A/CD5AC048 39,500 NONE CC5A/CD5AW042 40,000 NONE CC5A/CD5AW048 40,500 NONE CD5AA048 40,500 NONE CE3AA042 40,000 NONE CE3AA048 40,500 NONE CF5AA048 40,500 NONE CK3BA042 40,000 NONE CK3BA048 40,500 NONE CK5A/CK5BA042 40,000 NONE CK5A/CK5BA048 40,500 NONE CK5A/CK5BE042 40,500 NONE CK5A/CK5BT042 40,000 NONE CK5A/CK5BT048 40,500 NONE CK5A/CK5BW048 40,500 NONE PF1MNB042 40,000 TDR PF1MNB048 41,000 TDR PF1MNB071 42,000 TDR&TXV *CD5AA048 44,000 NONE CC5A/CD5AA060 44,000 NONE CC5A/CD5AC048 43,000 NONE CC5A/CD5AW048 44,000 NONE CC5A/CD5AW060 44,500 NONE CE3AA048 44,000 NONE CE3AA060 44,500 NONE CF5AA048 44,000 NONE CK3BA048 44,000 NONE CK3BA060 44,000 NONE CK5A/CK5BA048 44,000 NONE CK5A/CK5BA060 44,000 NONE CK5A/CK5BT048 44,000 NONE CK5A/CK5BT060 44,000 NONE CK5A/CK5BW048 44,000 NONE CK5A/CK5BX060 44,500 NONE PF1MNA048 44,500 TDR PF1MNA060 45,000 TDR PF1MNA070 45,500 TDR PF1MNA071 45,000 TDR&TXV PF1MNB048 44,500 TDR PF1MNB060 45,000 TDR PF1MNB070 45,500 TDR PF1MNB071 45,000 TDR&TXV *CD5AA048 45,500 NONE CC5A/CD5AA060 45,500 NONE CC5A/CD5AC048 44,500 NONE CC5A/CD5AW048 45,500 NONE CC5A/CD5AW060 46,000 NONE CE3AA048 45,500 NONE CE3AA060 46,000 NONE CF5AA048 45,500 NONE CK3BA048 45,500 NONE CK3BA060 45,500 NONE CK5A/CK5BA048 45,500 NONE CK5A/CK5BA060 45,500 NONE CK5A/CK5BT048 45,500 NONE CK5A/CK5BT060 45,500 NONE CK5A/CK5BW048 45,500 NONE CK5A/CK5BX060 46,000 NONE PF1MNB048 45,500 TDR PF1MNB060 46,000 TDR PF1MNB070 46,500 TDR PF1MNB071 46,500 TDR&TXV *CC5A/CD5AW060 57,000 NONE CC5A/CD5AA060 56,000 NONE CE3AA060 57,000 NONE CK3BA060 56,000 NONE CK5A/CK5BA060 56,000 NONE CK5A/CK5BT060 56,000 NONE CK5A/CK5BX060 57,000 NONE PF1MNA060 57,500 TDR PF1MNA070 58,000 TDR PF1MNA071 58,000 TDR&TXV PF1MNB060 57,500 TDR PF1MNB070 58,000 TDR PF1MNB071 58,000 TDR&TXV EER 9

10 * Tested Combination In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Payne furnaces are equipped with TDR. Requires hard shutoff TXV; based on computer simulation. EER Energy Efficiency Ratio SEER Seasonal Energy Efficiency Ratio TDR Time-Delay Relay TXV Thermostatic Expansion Valve N/A Not Applicable NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan-coil or furnace-coil literature. 4. Minimum outdoor operating ambient in cooling mode is 55 F (12.8 C), maximum 115 F (46.1 C). 5. The dashes ( ) appearing in the SEER WITH ACCESSORY TDR column indicate no improvement in efficiency due to time-delay function built into unit as manufactured (see table). 10

11 EVAPORATOR CFM EWB DETAILED COOLING CAPACITIES* CONDENSER ENTERING TEMPERATURES F Sens kw** Sens kw** Sens kw** Sens kw** Sens PA10JA018-C Outdoor Section With CC5A/CD5AA018 Section kw** Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA FF1DNA CC5A/CD5AW FF1DNE CE3AA CF5AA PF1MNA CK3BA CK5A/CK5BA PF1MNB CK5A/CK5BW PA10JA024-C Outdoor Section With CC5A/CD5AA024 Section Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA CK5A/CK5BW CC5A/CD5AW FF1DNA CE3AA FF1DNE CF5AA PF1MNA CK3BA PF1MNB CK5A/CK5BA See notes on page

12 EVAPORATOR CFM EWB DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING TEMPERATURES F Sens kw** Sens kw** Sens kw** Sens kw** Sens PA10JA030-C Outdoor Section With CC5A/CD5AA030 Section kw** Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA CK5A/CK5BT CK5A/CK5BW CC5A/CD5AW FF1DNA CE3AA FF1DNE PF1MNA CF5AA CK3BA PF1MNB CK5A/CK5BA PA10JA036-B Outdoor Section With CC5A/CD5AA036 Section Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA CK3BA CC5A/CD5AW CK5A/CK5BA CE3AA CK5A/CK5BT CF5AA CK5A/CK5BW See notes on page

13 EVAPORATOR CFM EWB DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING TEMPERATURES F Sens kw** Sens kw** Sens kw** Sens kw** Sens PA10JA036-C Outdoor Section With CC5A/CD5AA036 Section kw** Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA CK5A/CK5BT CC5A/CD5AW CK5A/CK5BW PF1MNA CE3AA CF5AA PF1MNB CK3BA CK5A/CK5BA PA10JA042-C, D Outdoor Section With CC5A/CD5AA042 Section Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA CK5A/CK5BA CC5A/CD5AC CC5A/CD5AW CK5A/CK5BE CK5A/CK5BT CD5AA CE3AA CK5A/CK5BW PF1MNB CF5AA CK3BA See notes on page

14 EVAPORATOR CFM EWB DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING TEMPERATURES F Sens kw** Sens kw** Sens kw** Sens kw** Sens PA10JA047-C Outdoor Section With CC5A/CD5AA048 Section kw** Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA CK5A/CK5BT CC5A/CD5AC CC5A/CD5AW CK5A/CK5BW CK5A/CK5BX CD5AA PF1MNA CE3AA CF5AA CK3BA PF1MNB CK5A/CK5BA PA10JA048-C, D Outdoor Section With CC5A/CD5AA048 Section Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA CK5A/CK5BA CC5A/CD5AC CC5A/CD5AW CK5A/CK5BT CD5AA CK5A/CK5BW CE3AA CK5A/CK5BX PF1MNB CF5AA CK3BA See notes on page

15 EVAPORATOR CFM EWB DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING TEMPERATURES F Sens kw** Sens kw** Sens kw** Sens kw** Sens PA10JA060-C Outdoor Section With CC5A/CD5AA060 Section kw** Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA PF1MNA CC5A/CD5AW PF1MNA CE3AA PF1MNA CK3BA PF1MNB CK5A/CK5BA PF1MNB CK5A/CK5BT PF1MNB CK5A/CK5BX * Detailed cooling capacities are based on indoor and outdoor unit at same elevation per ARI standard 210/ If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. and sensible capacities are net capacities. Blower motor heat has been subtracted. Sensible capacities shown are based on 80 F (27 C) entering air at the indoor coil. For sensible capacities at other than 80 F (27 C), deduct 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80 F (27 C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air per degree above 80 F (27 C). When the required data falls between the published data, interpolation may be performed. ** Unit kw is total of indoor and outdoor unit kilowatts. 15

16 SYSTEM DESIGN 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc. 2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55 F (12.8 C). 3. Maximum outdoor operating air temperature is 125 F (51.7 C). 4. For reliable operation, unit should be level in all horizontal planes. 5. Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 50 ft, indoor coil below = 150 ft. 6. For interconnecting refrigerant tube lengths greater than 50 ft or 20 ft vertical differential, consult Long-Line Application Guideline available from equipment distributor. 7. Crankcase heater required when interconnecting refrigerant tube length exceeds 50 ft. 8. If any refrigerant tubing is buried, provide a minimum 6 in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in. may be buried without further consideration. For buried lines longer than 3 ft, consult your local distributor. 9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: SS-PA Payne Heating & P.O. Box 70, Indianapolis, IN 406 PRINTED IN U.S.A. Catalog No. 52PA

Product Data. 38CKC 60 Hz Air Conditioner. Sizes 018 thru 060 AVAILABLE OPTIONS

Product Data. 38CKC 60 Hz Air Conditioner. Sizes 018 thru 060 AVAILABLE OPTIONS Product Data 38CKC 60 Hz Air Conditioner Sizes 018 thru 060 Model 38CKC Energy-Efficient Air Conditioner incorporates innovative technology to provide reliable summer cooling performance. Built into these

More information

Product Data. 38TKB (60 Hz) Air Conditioner. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38TKB (60 Hz) Air Conditioner. Sizes 018 thru 060 FEATURES/BENEFITS HEATING & COOLING Product Data 38TKB (60 Hz) Air Conditioner Sizes 018 thru 060 Model 38TKB Energy-Efficient Air Conditioner incorporates innovative technology to provide quiet, reliable summer cooling

More information

Bosch BOVA Split System Heat Pump

Bosch BOVA Split System Heat Pump Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications Product Specifications Split System Heat Pump Up to 18 SEER 2-3-4-5 Ton Capacity R410A

More information

AIR COOLED CONDENSERS

AIR COOLED CONDENSERS AIR COOLED CONDENSERS SELECTION GUIDE Data Aire, Inc. 230 W. BlueRidge Ave. Orange, CA 92865 www.dataaire.com TABLE OF CONTENTS DARC - Standard outdoor condenser general description... 3 DARC LD - Low

More information

AA1C AIR CONDITIONER SS-AA1C-03

AA1C AIR CONDITIONER SS-AA1C-03 VILLE SIZES: NMINL SEER RTINGS: ERTIFITIN: ELETRIL RNGE: MPRESSR PRTETIN: FN MTR: IL DESIGN: 1 18,000 to 60,000 tuh 1 10.0 UL, c-ul, RI, and E Listed 208 230v, 60 Hertz, 1 Phase Each compressor is protected

More information

Side Channel R ing Blower

Side Channel R ing Blower Side Channel R ing Blower ------------------------------------- INSTRUCTION MNUL ------------------------------------ RB20../ 30../ 40../ 50../ 60 / 80.. SERIES CONTENT PGE 1. SFETY REQUIREMENT... 1 2.

More information

SED2 VFD NEMA Type 3R Bypass, and Type 3R Harsh Environment (3RHE) Bypass

SED2 VFD NEMA Type 3R Bypass, and Type 3R Harsh Environment (3RHE) Bypass Document No. 129-405 SED2 VFD NEMA Type 3R Bypass, and Type 3R Harsh Environment (3RHE) Bypass Product Description The SED2 VFD NEMA Type 3R/3RHE, Bypasses are companion packages for the family of SED2

More information

Datasheet BR Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors

Datasheet BR Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors Datasheet BR Series /CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors NEW Compared to traditional fuse installation, the /CSA C22.2 No.5-02, UL1077/CSA

More information

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options Product Description The SED2 Conventional Bypass (C-Bypass) Options are companion packages for the family of SED2 Variable Frequency

More information

JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA

JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA TYPICAL APPLICATIONS All general loads, indoors or outdoors, including lighting, industrial & commercial Schools Hospitals Factories Office

More information

Areamaster 250/400 Integrally Ballasted Floodlights 100 W to 400 W HID For hazardous and marine locations.

Areamaster 250/400 Integrally Ballasted Floodlights 100 W to 400 W HID For hazardous and marine locations. Lighting HID NEC/CEC ENCLOSED AND GASKETED CLASS/ZONE RATED FLOODLIGHT Applications Powerful, efficient weatherproof lighting for medium and large areas such as: Pulp and paper mills Processing plants

More information

MOTOR STARTING AUTOTRANSFORMERS

MOTOR STARTING AUTOTRANSFORMERS S Copper Wound Two Coil and Three Coil Description and Applications... 132 Copper Standard Specifications... 133 Copper, Three Phase, 2 Coil Selection Tables... 134 Copper, Three Phase, 3 Coil Selection

More information

Standards. n Built in accordance with NEMA, ANSI, UL and CSA standards

Standards. n Built in accordance with NEMA, ANSI, UL and CSA standards Drive Isolation 4 3 to 990 kva Applications n For industrial and commercial applications with SCR-controlled adjustable speed motor drives, and AC adjustable frequency or DC drives Specifications n NEMA1

More information

System Multiplexer / Permissive Module

System Multiplexer / Permissive Module System Multiplexer / (Cat 2030-MLXxxx-SYSx) ATTETIO: Hazardous Voltage or other forms of energy could be present. To avoid serious injury or death: rior to beginning the installation and wiring process,

More information

PROBE CONDITIONING SYSTEM- P/N FOR BATCH FURNACES

PROBE CONDITIONING SYSTEM- P/N FOR BATCH FURNACES December 3, 2007 PROBE CONDITIONING SYSTEM- P/N 13011 FOR BATCH FURNACES INSTRUCTION MANUAL M4505E SSi SUPER SYSTEMS INC. 7205 Edington Drive Cincinnati, Ohio 45249 1-513- 772-0060 1-800- 666-4330 FAX

More information

STATE-COM-GAS-State Commercial Gas Water Heaters RW List Prices - Page T-59

STATE-COM-GAS-State Commercial Gas Water Heaters RW List Prices - Page T-59 RW List Prices - Page T-59 SANDBLASTER SBS LIGHT DUTY GAS 3 Year Limited Warranty on Tank 1 Year Limited Warranty on Parts Part # Description Price 26310110 SBS65-65NE 3Yr Nat Com Wtr Htr Call 26310210

More information

VLT HVAC Drive. Variable Frequency Drive w/ Electro-Mechanical Bypass Guide Specification. Section 15172

VLT HVAC Drive. Variable Frequency Drive w/ Electro-Mechanical Bypass Guide Specification. Section 15172 VLT HVAC Drive Variable Frequency Drive w/ Electro-Mechanical Bypass Guide Specification I. PART 1- GENERAL A. DESCRIPTION Section 15172 1. This specification covers complete a variable frequency drives

More information

HarmonicGuard Series Drive-Applied Harmonic Filter Installation, Operation, and Maintenance Manual

HarmonicGuard Series Drive-Applied Harmonic Filter Installation, Operation, and Maintenance Manual HarmonicGuard Series Drive-Applied Harmonic Filter Installation, Operation, and Maintenance Manual TCI, LLC W132 N10611 Grant Drive Germantown, Wisconsin 53022 Phone: 414-357-4480 Fax: 414-357-4484 Helpline:

More information

McQuay. Enclosed Variable Frequency Drive MED. Replacement Parts List No New 09/2008

McQuay. Enclosed Variable Frequency Drive MED. Replacement Parts List No New 09/2008 Replacement Parts List No. 700011800 New 09/2008 McQuay Enclosed Variable Frequency Drive MED To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com Contents

More information

KM-1600SWE KM-1600SWE3 KM-1600SRE KM-1600SRE3

KM-1600SWE KM-1600SWE3 KM-1600SRE KM-1600SRE3 ISSUED: REVISED: 71089 DEC. 22, 1992 DEC. 1, 2004 HOSHIZAKI STACKABLE CRESCENT CUBER MODEL KM-1600SWE KM-1600SWE3 KM-1600SRE KM-1600SRE3 (FINAL) S LIST KM-1600SWE D-0 May, 1994 E-0 Jan., 1995 E-1 June,

More information

Medescan Nebuliser Med - S600A Instructions Manual

Medescan Nebuliser Med - S600A Instructions Manual Medescan Nebuliser Med - S600A Instructions Manual Please read this guidebook carefully before operating this unit Your Nebuliser is intended for use in the treatment of asthma, COPD and other respiratory

More information

NOE LOBBY RANGE NOE LOBBY C - 1/2 hrs CMV/Collective extraction units Flow rate 400 to m 3 /h COLLECTIVE VENTILATION

NOE LOBBY RANGE NOE LOBBY C - 1/2 hrs CMV/Collective extraction units Flow rate 400 to m 3 /h COLLECTIVE VENTILATION COLLECTIVE VENTILATION NOE LOBBY RANGE NOE LOBBY 4 4 C - 1/2 hrs CMV/Collective extraction units Flow rate 4 to 114 m 3 /h 4 4 COLLECTIVE VENTILATION Ventilation unit PULLEY/BELT TRANSMISSION 4 to 114

More information

VLT HVAC Drive. Variable Frequency Drive w/ Electronically Controlled Bypass Guide Specification. Section 15172

VLT HVAC Drive. Variable Frequency Drive w/ Electronically Controlled Bypass Guide Specification. Section 15172 VLT HVAC Drive Variable Frequency Drive w/ Electronically Controlled Bypass Guide Specification I. PART 1- GENERAL A. DESCRIPTION Section 15172 1. This specification covers complete a variable frequency

More information

Installation Instructions

Installation Instructions Instructions Midrange Self-Contained Unit Accessory: Indeeco Electric Heat Used with Models SCWJ, SCRJ 3, 5, 7.5, 10, 12, and 15 Tons AO and later design sequence SAFETY WARNING Only qualified personnel

More information

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type ABB Manual Motor Starter General Information Extended Product Type Product ID 1SAM250000R1008 EAN 4013614320316 Catalog Description Long Description Manual Motor Starter The manual motor starter (also

More information

3. Dimensions, weights Placement and Assembly Pressure drops Noise data Material... 14

3. Dimensions, weights Placement and Assembly Pressure drops Noise data Material... 14 These technical specifications state a row of manufactured sizes and models of smoke extraction dampers - single (further only dampers) SEDS-L. It is valid for production, designing, ordering, delivery,

More information

QUALITY WEATHERPROOF ELECTRICAL EQUIPMENT

QUALITY WEATHERPROOF ELECTRICAL EQUIPMENT MIDWEST ELETRI PRODUTS, IN IR ONDITIONIN DISONNETS Metallic & Non-Metallic QULITY WETHERPROOF ELETRIL EQUIPMENT / DISONNETS P065P1 PPLITION INFORMTION rticle 440 of the National Electrical ode applies

More information

Compressor Accessories

Compressor Accessories Compressor Accessories Series 11 Superior quality for superior performance COMPRESSOR OIL Description MINERAL 11.1100 1 litre container 11.1400 4 litre container SYNTHETIC 11.1200 1 litre container 11.1500

More information

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type ABB MS132-6.3 Manual Motor Starter General Information Extended Product Type Product ID MS132-6.3 1SAM350000R1009 EAN 4013614400094 Catalog Description Long Description MS132-6.3 Manual Motor Starter The

More information

Compressor Nebulizer System

Compressor Nebulizer System MedPro The Professional Choice Le choix des professionnels MedProTM MC Compressor Nebulizer System 705-445 Instruction Manual Index 1. Introduction...2 2. Product Identification...2 3. Important Safeguards...3

More information

Frequently Asked Questions

Frequently Asked Questions Frequently Asked Questions How does the SMRT-Y work? The SMRT-Y sensor accurately measures the moisture level in the soil. When the soil is dry, the SMRT-Y allows the irrigation controller to water as

More information

PORTABLE COMPRESSOR NEBULIZER Guidebook & Manual Reorder No. 5606

PORTABLE COMPRESSOR NEBULIZER Guidebook & Manual Reorder No. 5606 PORTABLE COMPRESSOR NEBULIZER Guidebook & Manual Reorder No. 5606 Please read this guidebook carefully before operating this unit. Your Nebulizer is intended for use in the treatment of asthma, COPD and

More information

MS MS Manual Motor Starter. Generell informasjon. Ordering. Popular Downloads. Dimensions. Technical MS Extended Product Type

MS MS Manual Motor Starter. Generell informasjon. Ordering. Popular Downloads. Dimensions. Technical MS Extended Product Type ABB Manual Motor Starter Generell informasjon Extended Product Type Product ID 1SAM451000R1015 EAN 401614486098 Catalog Description Long Description Manual Motor Starter MS165 is a compact and powerful

More information

HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT. Instruction Manual

HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT. Instruction Manual HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT Instruction Manual TABLE OF CONTENTS IEC Symbols...2 Important Safeguards...2 Introduction...3 Specifications...4

More information

GRUNDFOS DATA BOOKLET. BM, BMhp. Booster Modules 50/60 Hz

GRUNDFOS DATA BOOKLET. BM, BMhp. Booster Modules 50/60 Hz GRUNDFOS DATA BOOKLET BM, BMhp Booster Modules 5/6 z BM, BMhp Table of contents 1. BM applications 4 Pumped liquids 4 2. BM product introduction 4 Standard pumps 4 Construction 4 Motor 4 3. BM, BMhp performance

More information

Armstrong IVS 102 Drive Specification

Armstrong IVS 102 Drive Specification Armstrong IVS 102 Drive Specification Part I: General Description 1. This specification covers complete variable frequency drives (VFDs) designated on the drawing schedules to be variable speed. All standard

More information

Compressor Nebulizer. Guidebook

Compressor Nebulizer. Guidebook NSTRU Compressor Nebulizer Guidebook MODEL: MQ6002 READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE Compressor Nebulizer MODEL NO: MQ6002 INSTRUCTIONS INDEX 1. Introduction ----------------------------------------------------------------

More information

Premium Chemical Free Iron/Sulphur Filter Installation Manual

Premium Chemical Free Iron/Sulphur Filter Installation Manual Premium Chemical Free Iron/Sulphur Filter Installation Manual 220 Bayview Avenue Unit 18 Barrie, Ontario, Canada, L4N 4Y8 www.excaliburwater.com EXCALIBUR PREMIUM CHEMICAL FREE IRON/SULPHUR FILTER INSTALLATION

More information

BH Fitness T4 / T6 SPORT Treadmill Owner s Manual

BH Fitness T4 / T6 SPORT Treadmill Owner s Manual BH Fitness T4 / T6 SPORT Treadmill Owner s Manual BEFORE YOU BEGIN It is very important to become familiar with the frequently used components of your treadmill. Computer Console Circuit Breaker ON/OFF

More information

Easy assembly with standard tools. Fully insulated for direct mounting to steel panels

Easy assembly with standard tools. Fully insulated for direct mounting to steel panels Cam-Lok J Series Connectors or NEMA 4 Cam-Lok J Series Connectors are specifically designed to meet the needs of demanding portable applications. J Series Plugs and Receptacles are the proven industry

More information

OWNER'S MANUAL OxyTrainer

OWNER'S MANUAL OxyTrainer M Model # 7102 OWNER'S MANUAL OxyTrainer WE WE ARE ARE HERE HERE TO TO HELP HELP YOU YOU 1-866-924-1688 Email: service@paradigmhw.com Address: Paradigm Health & Wellness, Inc. 1189 Jellick Ave. City of

More information

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL 1 2 Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...

More information

2YEARS. three-phase kVA. Digital voltage stabiliser Orion Plus. Standard features. Voltage stabilisation PC selectable output voltage

2YEARS. three-phase kVA. Digital voltage stabiliser Orion Plus. Standard features. Voltage stabilisation PC selectable output voltage «WARRANTY«WARRANTY«WARRANTY«WARRANTY 2YEARS Digital stabiliser Standard features Voltage stabilisation PC selectable output Independent phase control Frequency 50/60Hz ±5% Admitted load variation Up to

More information

Stepper Motors and Control Part II - Bipolar Stepper Motor and Control (c) 1999 by Rustle Laidman, All Rights Reserved

Stepper Motors and Control Part II - Bipolar Stepper Motor and Control (c) 1999 by Rustle Laidman, All Rights Reserved Copyright Notice: (C) June 2000 by Russell Laidman. All Rights Reserved. ------------------------------------------------------------------------------------ The material contained in this project, including

More information

Cerus P-Series General Specifications Section 15172

Cerus P-Series General Specifications Section 15172 Cerus P-Series s Section 15172 Variable Frequency Drives PART 1-GENERAL 1.01 SECTION INCLUDES A. Variable Frequency Drive(VFD) 1.02 RELATED SECTIONS A. Section 16195 1.03 REFERENCES A. NEMA250 B. EN 50178

More information

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...

More information

HPS MILLENNIUM GENERAL PURPOSE MEDIUM VOLTAGE Distribution

HPS MILLENNIUM GENERAL PURPOSE MEDIUM VOLTAGE Distribution HPS MILLENNIUM GENERAL PURPOSE MEDIUM VOLTAGE Distribution TRANSFORMERS 2.5 KV to 5KV Class Dry Type Single Phase and Three Phase Medium Voltage Energy Efficient Guidelines... 254 Energy Efficient Guidelines

More information

Variable Frequency Drives

Variable Frequency Drives Variable Frequency Drives Date : Feb 09, 2015-07:30 AM - Feb 10, 04:30 PM Event URL : http:///events/variable-frequency-drives-feb-2015-rochester- Organizer : American Traincoâ Venue : Location : Rochester

More information

AC CENTRIFUGAL FORWARD CURVED FAN 133 x 190

AC CENTRIFUGAL FORWARD CURVED FAN 133 x 190 Micromotori Elettrici Svizzera Motor Type AC CENTRIFUGAL FORWARD CURVED FAN 133 x 19 Code: 3.9775 Project code: Poles Stator Impeller Type -4 V 5/6 Hz ~ 1 1 M35 Centrifugal Forward Curved Blade double

More information

CABINA S40 USER MANUAL AUDIOMETRIC TEST BOOTH MU2 REV. 1.05

CABINA S40 USER MANUAL AUDIOMETRIC TEST BOOTH MU2 REV. 1.05 CABINA S40 AUDIOMETRIC TEST BOOTH USER MANUAL 501-700-MU2 REV. 1.05 S40 AUDIOMETRIC TEST BOOTH * USER MANUAL * Rev. 1.05 CONTENTS 1. INSTRUCTIONS FOR USE AND INSTALLATION 1-1 1.1. INTRODUCTION 1-1 1.2.

More information

ER75 Electro-Acoustic Ear Simulator. Operating Manual

ER75 Electro-Acoustic Ear Simulator. Operating Manual ER75 Electro-Acoustic Ear Simulator Operating Manual ABOUT THIS MANUAL READ THIS OPERATING MANUAL BEFORE ATTEMPTING TO USE THE INSTRUMENT. Amplivox Ltd. 6 Oasis Park, Eynsham Oxfordshire, OX29 4TP United

More information

Mini UPS and Power Sensor. Power Output Cord. Power Input Port. Switch Port

Mini UPS and Power Sensor. Power Output Cord. Power Input Port. Switch Port AVTECH Mini UPS and Power Sensor AVTECH s Mini UPS and Power Sensor (MUPS) monitors the on/off state of a power source, such as main power, a UPS, surge protector or standard wall outlet, and also provides

More information

S201-C2. Miniature Circuit Breaker - S200-1P - C - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

S201-C2. Miniature Circuit Breaker - S200-1P - C - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions. ABB Miniature Circuit Breaker - S200-1P - C - 2 ampere General Information Extended Product Type Product ID 2CDS251001R0024 EAN 40167795225 Catalog Description Long Description Miniature Circuit Breaker

More information

THE TOTALLY WICKED TORNADO NC CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED TORNADO NC ELECTRONIC CIGARETTE KIT

THE TOTALLY WICKED TORNADO NC CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED TORNADO NC ELECTRONIC CIGARETTE KIT USER MANUAL THE TOTALLY WICKED TORNADO NC CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED TORNADO NC ELECTRONIC CIGARETTE KIT 3 QUICK START GUIDE For those familiar with e-cigarettes, the steps below

More information

RDP/DDP REDUNDANT/DUPLEX DRIVE PACKAGE

RDP/DDP REDUNDANT/DUPLEX DRIVE PACKAGE RDP/DDP REDUNDANT/DUPLEX DRIVE PACKAGE USER MANUAL Franklin Control Systems 11/11/2013 Table of Contents 1. Safety precautions... 1 2. Legends & Introduction... 2 3. Installation and wiring... 3 4. Setup...

More information

Environmental Submersible Pumps

Environmental Submersible Pumps Environmental Submersible Pumps Grundfos 85S Enviro Retrofitted Submersible Pumps These Grundfos submersible pumps are made of stainless steel and retrofitted with PTFE to handle the rigors of contaminated

More information

SPECIFICATION GUIDE. Phoenix EX AC Drive Closed Loop AC Vector Control 3 HP to 3500 HP 200 to 600 VAC Input

SPECIFICATION GUIDE. Phoenix EX AC Drive Closed Loop AC Vector Control 3 HP to 3500 HP 200 to 600 VAC Input US Drives Inc. 2221 Niagara Falls Boulevard P.O. Box 281 Niagara Falls, NY 14304-0281 Tel: (716) 731-1606 Fax: (716) 731-1524 Visit us at www.usdrivesinc.com GUIDE Phoenix EX AC Drive Closed Loop AC Vector

More information

BM, BMhp. Lenntech. Lenntech. Booster modules 50/60 Hz. Tel Fax.

BM, BMhp. Lenntech. Lenntech. Booster modules 50/60 Hz. Tel Fax. GRUNDFOS DATA BOOKLET BM, BMhp Booster modules 5/6 z Lenntech info@lenntech.com Tel. +31-152-61-9 www.lenntech.com Fax. +31-152-616-289 Lenntech BM, BMhp Table of contents 1. Performance ranges 3 BM, 5

More information

Compressor Nebulizer. Guidebook

Compressor Nebulizer. Guidebook NSTRU Compressor Nebulizer Guidebook MODEL: CN02WS (MQ6003) READ ALL INSTRUCTION BEFORE USE Airial TM Compressor Nebulizer INSTRUCTIONS INDEX 1. Introduction ----------------------------------------------------------------

More information

Applications. Projected Area: 1.9 Sq. Ft. Dimensions in Inches/Millimeters

Applications. Projected Area: 1.9 Sq. Ft. Dimensions in Inches/Millimeters NEC/CEC: Applications Powerful, efficient weatherproof lighting for medium and large areas such as: Shopping malls Parking lots Sports areas New-car lot lighting Security lighting Industrial process lighting

More information

Environmental Submersible Pumps

Environmental Submersible Pumps Environmental Submersible Pumps Grundfos 300S Enviro Retrofitted Submersible Pumps These Grundfos submersible pumps are made of stainless steel and retrofitted with PTFE to handle the rigors of contaminated

More information

DIVISION 15 - MECHANICAL. Section Variable Frequency Drives. Introduction

DIVISION 15 - MECHANICAL. Section Variable Frequency Drives. Introduction DIVISION 15 - MECHANICAL Section 15870 Variable Frequency Drives Introduction This specification is to cover a complete variable frequency motor drive (VFD) consisting of a pulse width modulated (PWM)

More information

ELECTRONIC CIGARETTE KIT USER MANUAL

ELECTRONIC CIGARETTE KIT USER MANUAL ELECTRONIC CIGARETTE KIT USER MANUAL Mouthpiece Sliding Top Cap CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED OPTIMUS ELECTRONIC CIGARETTE KIT. Airflow Control Ring LED Indicator Light OLED Screen

More information

Advanced Research Systems, Inc.

Advanced Research Systems, Inc. 4/17/01 Page 1 Huber Goniometer Interface 6.5K to 800K Closed Cycle Cryostat DESCRIPTION The DE-202G has been designed for applications requiring movement of the refrigerator, specifically for goniometers.

More information

Compressor Nebulizer Instruction Manual Part No.: 5055

Compressor Nebulizer Instruction Manual Part No.: 5055 Compressor Nebulizer Instruction Manual Part No.: 5055 DISTRIBUTED BY: SAVE THESE INSTRUCTIONS. CAUTION - U.S. Federal Law restricts this device to sale by or on the order of a physician. 666002-6310 V1.3

More information

Air Preparation Equipment

Air Preparation Equipment FRLS Improve system efficiency Side-by-side and stacking units available Modular design for easy connection and maintenance Variety of port sizes from #10-30 to 1" NPT pp. 170-174 FILTERS Capture solid

More information

Environmental Submersible Pumps

Environmental Submersible Pumps Environmental Submersible Pumps Grundfos 230S Enviro Retrofitted Submersible Pumps These Grundfos submersible pumps are made of stainless steel and retrofitted with PTFE to handle the rigors of contaminated

More information

PAMA PASSIVES 1GHz DROP PASSIVES WITH F CONNECTORS

PAMA PASSIVES 1GHz DROP PASSIVES WITH F CONNECTORS PAMA PASSIVES 1GHz DROP PASSIVES WITH F CONNECTORS Vertical Splitters ISV Series Vertical from two to eight ports Frequency range: 5-1000 MHz Two-way system compatible Outdoor/Indoor Uses IM2: -60/55 dbmv/dbmv

More information

RLS/BP MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES. RLS 300/BP MX 600/ kw RLS 400/BP MX 800/ kw DUAL FUEL.

RLS/BP MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES. RLS 300/BP MX 600/ kw RLS 400/BP MX 800/ kw DUAL FUEL. RLS/BP MX series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above all,

More information

Features CONSTANT WATTAGE AUTOTRANSFORMER 1.9 SQ FT Lamp Included 0 MOGUL BASE HIGH PRESSURE SODIUM

Features CONSTANT WATTAGE AUTOTRANSFORMER 1.9 SQ FT Lamp Included 0 MOGUL BASE HIGH PRESSURE SODIUM GAM671L48I2 250W HPS Flood Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category GAM671L48I2 Appleton/Oz Gedney Floodlight, Mogul Base High Pressure Sodium Lamp; Lamp

More information

TABLE OF CONTENTS. 2.0 USING MANAGER PREFERENCE 2.1 Using manager preference mode 2.2 Selecting US or metric 2.3 Using CSafe

TABLE OF CONTENTS. 2.0 USING MANAGER PREFERENCE 2.1 Using manager preference mode 2.2 Selecting US or metric 2.3 Using CSafe E L L I P T I C A L T O T A L B O D O W N E R S M A N U A L TABLE OF CONTENTS 1.0 IMPORTANT SAFET INSTRUCTIONS Read and save these instructions Setting up the Elliptical total body 1.1 Installation requirements

More information

Manu Part # Global # Item Description For use with Global#

Manu Part # Global # Item Description For use with Global# Manu Part # Global # Item Description For use with Global# ZD41000C B2144826 Nilfisk-Advance Replacement Part - Motor 120V Vn1500 - ZD41000C 261120 VF99024D B2144876 Nilfisk-Advance Replacement Part -

More information

The Phalanx. Featuring Evolv DNA250 Technology. ***Keep Out of reach of children. This device is for persons 18yrs of age or older ***

The Phalanx. Featuring Evolv DNA250 Technology. ***Keep Out of reach of children. This device is for persons 18yrs of age or older *** The Phalanx Featuring Evolv DNA250 Technology ***Keep Out of reach of children. This device is for persons 18yrs of age or older *** Congratulations on your purchase of the Phalanx DNA250 temperature protected

More information

EXPANSION VALVES (TXV)

EXPANSION VALVES (TXV) Table of Contents Basic Information (TXV) The expansion valve (also referred to as TXV) is located at the evaporator inlet; controlling the flow of refrigerant entering the evaporator based on the cooling

More information

SPORTSART C521M BI-DIRECTIONAL BIKE

SPORTSART C521M BI-DIRECTIONAL BIKE 2011.12 C521M BIKE SPORTSART C521M BI-DIRECTIONAL BIKE TABLE OF CONTENTS 1. INTRODUCTION... 2. IMPORTANT SAFETY PRECAUTIONS... 3. LIST OF PARTS... 1 2 6 4. ASSEMBLING THE PRODUCT STEP 0 Separate the Product

More information

RL/B MZ SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL RL 300/B MZ RL 400/B MZ. 600/ kw 1000/ kw

RL/B MZ SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL RL 300/B MZ RL 400/B MZ. 600/ kw 1000/ kw RL/B MZ series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above all, more

More information

DeVilbiss Pulmo-Aide Compact Compressor/Nebulizer Instruction Guide

DeVilbiss Pulmo-Aide Compact Compressor/Nebulizer Instruction Guide EN DeVilbiss Pulmo-Aide Compact Compressor/Nebulizer Instruction Guide Models 36D and 36I CAUTION Federal (U.S.A.) law restricts this device to sale by, or on the order of a physician. Made in U.S.A. of

More information

Trane TR150 Variable Frequency Drive Guide Specification Section GENERAL II. PRODUCTS

Trane TR150 Variable Frequency Drive Guide Specification Section GENERAL II. PRODUCTS Trane TR150 Variable Frequency Drive Guide Specification Section 15172 I. GENERAL A. This specification covers all variable frequency drives (VFDs) designated on the drawing schedules. All standard and

More information

RLS /M MX SERIES

RLS /M MX SERIES The RLS/M MX series of burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above

More information

Active Imaging TM transducers: Active Imaging 3-IN-1 Active Imaging SideScan

Active Imaging TM transducers: Active Imaging 3-IN-1 Active Imaging SideScan Active Imaging TM transducers: Active Imaging 3-IN-1 Active Imaging SideScan Installation manual ENGLISH www.simrad-yachting.com www.lowrance.com 1 Preface Warning: It is your sole responsibility to install

More information

Geräteblatt Pallazza III PGI

Geräteblatt Pallazza III PGI Technische Dokumentation Geräteblatt Pallazza III 535.08 PGI Geräteblatt Pallazza III 535.08 PGI Geräteblatt Pelletofen Fiche technique Poêle à pellets Scheda tecnica Stufe pellet Equipment sheet Pellet

More information

components IC, PB PSCK Pressure switches Digital pressure gauges Pressure gauges GA, GS NV, FM Gauge accessories A, AH/R HLS, H, T

components IC, PB PSCK Pressure switches Digital pressure gauges Pressure gauges GA, GS NV, FM Gauge accessories A, AH/R HLS, H, T Pressure switches t series IC, PB PSCK t page 188 Digital pressure gauges DG 189 Pressure gauges Gauge accessories Manifolds, couplers, hoses, tubing G GA, GS NV, FM A, AH/R HLS, H, T 190 191 192 High

More information

Installation Instructions

Installation Instructions Installation Instructions 1View Manager 96 Enhanced OUCH RACKER Contents About his Document...1 Planning the OUCH RACKER Network...1 Backbone Network Guidelines...2 Star Network Guidelines...2 Installing

More information

GlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

GlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System GlucCell TM SYSTEM USER S GUIDE Ver 2.1 Intended Use The GlucCell TM Glucose Monitoring System (The GlucCell TM System) is designed to quantitatively measure the concentration of glucose during cell culture.

More information

RJA RJA. Welded cabinet with demountable side panels and back panel, IP 20, loading capacity 600 kg

RJA RJA. Welded cabinet with demountable side panels and back panel, IP 20, loading capacity 600 kg 0 0 0 0 0 1 1 0 0 1 0 0 0 1 1 1 1 0 1 0 1 0 1 0 1 1 1 1 Welded cabinet with demountable side panels and back panel, IP 20, loading capacity kg 37 Strenghtened skeleton Cold-rolled steel 1,3 mm. Fringe

More information

X [dream] Gebrauchsanweisung User manual

X [dream] Gebrauchsanweisung User manual X [dream] Gebrauchsanweisung User manual English 09 10 Copyright 2015. StattQualm GmbH SQuape is a registered trademark of StattQualm GmbH in Switzerland and/or other Countries. Table of contents 1. Description

More information

Motorised Treadmill Model No: JI1625

Motorised Treadmill Model No: JI1625 BODYWORX Motorised Treadmill Model No: JI1625 Retain this owner s manual for future reference Read and follow all instructions in this owner s manual Version A 1 TABLE OF CONTENTS OVERVIEW DRAWING 2 ASSEMBLY

More information

Portable Equine Nebuliser System. User Manual

Portable Equine Nebuliser System. User Manual Portable Equine Nebuliser System User Manual Table of Contents INTENDED USE... 3 SAFETY INFORMATION... 3 TECHNICAL SPECIFICATION... 4 INSTRUCTIONS FOR USE... 6 MAINTENANCE... 12 TROUBLESHOOTING... 13 WARRANTY...

More information

MOTOR STARTING AUTOTRANSFORMERS

MOTOR STARTING AUTOTRANSFORMERS SCTION 5 MOTOR STARTING AUTOTRANSFORMRS Copper Wound Two Coil and Three Coil escription and Applications... 144 Copper Standard Specifications... 145 imensional rawings... 145 Copper, Three Phase, 2 Coil

More information

POWERED BY. 200Watts. Dual Batteries in Series

POWERED BY. 200Watts. Dual Batteries in Series POWERED BY 200Watts Dual 18650 Batteries in Series 1 1. OVERVIEW 2. STANDARD PACKAGE 3. MAIN FEATURES 4. BASIC OPERATION 5. PRECAUTIONS 6. WARRANTY 2 1. OVERVIEW Fire Button OLED Screen Display 510 Atomizer

More information

COLD LEAD OPTIONS FOR XMI MINERAL INSULATED (MI) HEATING CABLES

COLD LEAD OPTIONS FOR XMI MINERAL INSULATED (MI) HEATING CABLES FOR XMI MINERAL INSULATED (MI) HEATING CABLES PRODUCT OVERVIEW XMI with standard MI cold lead and Type X connector MI cable heated section PRODUCT OVERVIEW XMI with PyroFLX cold lead and Type K connector

More information

CITY OF WAUPACA, WISCONSIN WATER DEPARTMENT WATER SERVICE LATERAL THAWING RULES AND PROCEDURES (prepared February 24, 2015)

CITY OF WAUPACA, WISCONSIN WATER DEPARTMENT WATER SERVICE LATERAL THAWING RULES AND PROCEDURES (prepared February 24, 2015) CITY OF WAUPACA, WISCONSIN WATER DEPARTMENT WATER SERVICE LATERAL THAWING RULES AND PROCEDURES (prepared February 24, 2015) Pursuant to Wisconsin Public Service Commission 185.88 rules on Frozen Laterals:

More information

TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO

TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO THE AUDIOMETER PERFECT FOR EVERY PATIENT POPULATION GSI AUDIOSTAR PRO FAST AND EFFICIENT The GSI AudioStar Pro continues the tradition of excellence in clinical

More information

BH Fitness T8 SPORT Treadmill Owner s Manual

BH Fitness T8 SPORT Treadmill Owner s Manual BH Fitness T8 SPORT Treadmill Owner s Manual BEFORE YOU BEGIN It is very important to become familiar with the frequently used components of your treadmill. User Safety: SECTION 1 IMPORTANT SAFETY INSTRUCTIONS

More information

S201-Z2. Miniature Circuit Breaker - S200-1P - Z - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

S201-Z2. Miniature Circuit Breaker - S200-1P - Z - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions. ABB Miniature Circuit Breaker - S200-1P - Z - 2 ampere General Information Extended Product Type Product ID S201-Z2 2CDS251001R0278 EAN 40167795054 Catalog Description Long Description Miniature Circuit

More information

RLS/E-EV MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES

RLS/E-EV MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES The RLS/E-EV MX series of burners covers a firing range from 350 to 2400 kw, and they have been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil

More information

DeVilbiss Pulmo-Aide Compressor/Nebulizer Instruction Guide

DeVilbiss Pulmo-Aide Compressor/Nebulizer Instruction Guide EN DeVilbiss Pulmo-Aide Compressor/Nebulizer Instruction Guide Models 5650C, 5650D, 5650F, 5650I, 5650K & 5650P CAUTION Federal (U.S.A.) law restricts this device to sale by, or on the order of a physician.

More information