Easy assembly with standard tools. Fully insulated for direct mounting to steel panels
|
|
- Eric Lyons
- 5 years ago
- Views:
Transcription
1 Cam-Lok J Series Connectors or NEMA 4 Cam-Lok J Series Connectors are specifically designed to meet the needs of demanding portable applications. J Series Plugs and Receptacles are the proven industry standard single pole connectors for reliability and service with added safety. Applications: J Series Plugs and Receptacles are specifically designed for industrial power distribution applications requiring quick, tool-free connections Ideal for portable power, power distribution, motors, generators, and entertainment applications J Series replaces traditional hard wiring while cutting downtime and maintenance J Series Connectors are insulated, shatter/crack-resistant and watertight, plus heat-, weather-, ozone-, oil-, and abrasion-resistant Certifications and Compliances: Listed to UL498, File No. E67181 CSA certified to C22.2 No LR13963 Environmental Ratings: or NEMA 4 Standard Materials: Accepts cable sizes: #8 AWG MCM Insulator - elastomeric or rubber Contact - brass or copper Electrical Ratings: 600 Volts AC/DC 690 Amps continuous Temperature Ratings: -40 C to 105 C 1 Non-metallic retaining screw provides safe, strong and reliable contact retention 2 Easy assembly with standard tools 3 Retaining screw snaps into place to prevent loss 4 E-Z align drive pin increases torque and longitudinal strength 300% 5 Accommodates a wide range of cable sizes: #2 4/0 6 Integrated strain relief system s retaining wire prevents cable jacket pull-away 7 Non-vulcanized E1016 & EZ1016 plugs feature a high-strength, molded-inplace locking ring to capture and secure the insulator to the contact 8 Double set screw termination for added strength (crimp also available) 9 Fully insulated for direct mounting to steel panels 11 Snapback covers provide environmental seal 12 High impact-resistant thermoplastic protects receptacles from damage 10 Threaded stud and double set screw receptacles available (other terminations available) 1497
2 Cam-Lok J Series E1017 Non-vulcanized Plugs Cable Size MCM Up to 545A Continuous J Series E1017, Rubber, Non-vulcanized, Double Set Screw Connection Environmental rating: Accepts a wide range of cable sizes Ordering Information - Double Set Screw Non-vulcanized Male Plugs: MCM Black E A A MCM Red E A A MCM Green E A A MCM White E A A MCM Blue E A A MCM Brown E A A MCM Orange E A A MCM Yellow E A A E Ordering Information - Double Set Screw Non-vulcanized Female Plugs: MCM Black E A A MCM Red E A A MCM Green E A A MCM White E A A MCM Blue E A A MCM Brown E A A MCM Orange E A A MCM Yellow E A A E
3 Cam-Lok J Series E1017 Cable Size 250 MCM Up to 340A Continuous Environmental rating: Ordering Information - Crimp Vulcanized Male Plugs (Not UL Listed): 250 MCM Black E A A MCM Red E A A MCM Green E A A MCM White E A A MCM Blue E A A MCM Brown E A A MCM Orange E A A MCM Yellow E A A E Ordering Information - Crimp Vulcanized Female Plugs (Not UL Listed): 250 MCM Black E A A MCM Red E A A MCM Green E A A MCM White E A A MCM Blue E A A MCM Brown E A A MCM Orange E A A MCM Yellow E A A E
4 Cam-Lok J Series E1017 Cable Size 350 MCM Up to 445A Continuous Environmental rating: Ordering Information - Crimp Vulcanized Male Plugs: E Ordering Information - Crimp Vulcanized Female Plugs: 350 MCM Black E A A MCM Red E A A MCM Green E A A MCM White E A A MCM Blue E A A MCM Brown E A A MCM Orange E A A MCM Yellow E A A MCM Black E A A MCM Red E A A MCM Green E A A MCM White E A A MCM Blue E A A MCM Brown E A A MCM Orange E A A MCM Yellow E A A E
5 Cam-Lok J Series E1017 Cable Size 500 MCM Up to 545A Continuous Environmental rating: Ordering Information - Crimp Vulcanized Male Plugs: E Ordering Information - Crimp Vulcanized Female Plugs: 500 MCM Black E A A MCM Red E A A MCM Green E A A MCM White E A A MCM Blue E A A MCM Brown E A A MCM Orange E A A MCM Yellow E A A MCM Black E A A MCM Red E A A MCM Green E A A MCM White E A A MCM Blue E A A MCM Brown E A A MCM Orange E A A MCM Yellow E A A E
6 Cam-Lok J Series E1017 Cable Size 750 MCM Up to 690A Continuous Environmental rating: Ordering Information - Crimp Vulcanized Male Plugs: E Ordering Information - Crimp Vulcanized Female Plugs: 750 MCM Black E A A MCM Red E A A MCM Green E A A MCM White E A A MCM Blue E A A MCM Brown E A A MCM Orange E A A MCM Yellow E A A MCM Black E A A MCM Red E A A MCM Green E A A MCM White E A A MCM Blue E A A MCM Brown E A A MCM Orange E A A MCM Yellow E A A E
7 Cam-Lok J Series E1017 Cable Size 800 MCM Up to 690A Continuous Environmental rating: Ordering Information - Crimp Vulcanized Male Plugs (Not UL Listed): E MCM Black E A A MCM Red E A A MCM Green E A A MCM White E A A MCM Blue E A A MCM Brown E A A MCM Orange E A A MCM Yellow E A A Ordering Information - Crimp Vulcanized Female Plugs (Not UL Listed): 800 MCM Black E A A MCM Red E A A MCM Green E A A MCM White E A A MCM Blue E A A MCM Brown E A A MCM Orange E A A MCM Yellow E A A E
All dimensions are in mm. Plug: Coding Pin: HOODS TOP ENTRY HOODS. NPT Part # NP NP 10.
HA 3&4 Plugs & Receptacles HA 3&4 Housings: Single Lever on Base SCREW TERMINATED INSERTS HA 3 HA 4 All dimensions are in mm. HA 3 HA 4 Plug: 10.40 10.4310 Receptacle: 10.40 10.43 Coding Pin: 10.4513 TOP
More informationDatasheet BR Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors
Datasheet BR Series /CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors NEW Compared to traditional fuse installation, the /CSA C22.2 No.5-02, UL1077/CSA
More informationFittings & Accessories
Fittings & Accessories Adalet offers a range of fittings and accessories for use in general purpose or industrial locations. These fittings and accessories are used in conjunction with our industrial electrical
More informationMOTOR STARTING AUTOTRANSFORMERS
S Copper Wound Two Coil and Three Coil Description and Applications... 132 Copper Standard Specifications... 133 Copper, Three Phase, 2 Coil Selection Tables... 134 Copper, Three Phase, 3 Coil Selection
More informationHigh current plug-in connector
2017.12 High current plug-in connector with a wrong insertion prevention mechanism Plug-in Connector (A Wrong Insertion Prevention Mechanism) Features of the high current plug-in connector with a wrong
More informationSep2018 Rev B1
Product Specification 12Sep2018 Rev B1 HD30 Series Connector System 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the TE Connectivity (TE) HD30 Series
More informationAccessories for LV AirGuard Cables Glands, Connectors and Installation Tools.
Accessories for LV AirGuard Cables Glands, Connectors and Installation Tools. A Non-Potted Gland TECHNICAL DATA Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444 Mechanical Classifications*
More informationHPS MILLENNIUM GENERAL PURPOSE MEDIUM VOLTAGE Distribution
HPS MILLENNIUM GENERAL PURPOSE MEDIUM VOLTAGE Distribution TRANSFORMERS 2.5 KV to 5KV Class Dry Type Single Phase and Three Phase Medium Voltage Energy Efficient Guidelines... 254 Energy Efficient Guidelines
More informationProduct reference. LV switch-disconnectors 3. Product panorama 9. Functions and characteristics 17. Installation and connection 47
Product reference LV switch-disconnectors 3 Product panorama 9 Functions and characteristics 17 Installation and connection 47 Technical details 71 IS40 to 160 78 IS250 to 630 80 IV100 to 630 (visible
More informationEPIC CONNECTORS. STA Series
STA Series The STA inserts with solid spring designed contacts are used extensively in the construction of devices, in control units, laboratories, and withdrawable unit design. These inserts are available
More informationCOLD LEAD OPTIONS FOR XMI MINERAL INSULATED (MI) HEATING CABLES
FOR XMI MINERAL INSULATED (MI) HEATING CABLES PRODUCT OVERVIEW XMI with standard MI cold lead and Type X connector MI cable heated section PRODUCT OVERVIEW XMI with PyroFLX cold lead and Type K connector
More informationSPLICING CUSTOMER PREMISE WIRE AND CABLE GENERAL INSTRUCTIONS FOR SPLICING PREMISE WIRE...* *...
SOUTHWESTERN BELL TELEPHONE PRACTICE SWBT Standard SECTION SW 461-200-901 Issue A, June 1989 SPLICING CUSTOMER PREMISE AND CABLE CONTENTS PAGE 1. GENERAL...*..*...***.....0.0.00 0......0.....0......00..
More informationReplacement Parts for Raymond 8300, 8400 and 8500 Series
Replacement Parts for Raymond 8300, 800 and 800 Series Contents Quick Wheel Lookup Electrical System Components Battery Connector, Motor Controllers 6 Drive Unit & Drive Motor 8 Control Handle Arm, Throttle
More informationAssembly Instruction for Fiber Optic Series FOH Fischer Connectors
Assembly Instruction for Fiber Optic Series FOH Fischer Connectors Table des matières 1 Introduction... 3 2 Document history... 3 3 Definitions and Acronyms... 3 4 FOH Plugs & Receptacles with Potting
More informationStandards. n Built in accordance with NEMA, ANSI, UL and CSA standards
Drive Isolation 4 3 to 990 kva Applications n For industrial and commercial applications with SCR-controlled adjustable speed motor drives, and AC adjustable frequency or DC drives Specifications n NEMA1
More informationJEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA
JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA TYPICAL APPLICATIONS All general loads, indoors or outdoors, including lighting, industrial & commercial Schools Hospitals Factories Office
More informationBUSHINGS: GENERAL INFORMATION
BUSHINGS: GENERAL INFORMATION 1.0 Electrical characteristics (Ir = rated current; Ur = rated voltage) 1.1Standard insulation levels Rated voltage Ur kv (r.m.s.) 1 3,6 12 24 36 52 One minute power frequency
More informationSlideDriver 50VF. Modbus Controlled VFD Replacement Kit (MX4210, MX4211) REQUIRED TOOLS PARTS WORK SAFELY!
SlideDriver 50VF Modbus Controlled VFD Replacement Kit (MX420, MX42) The following instructions are intended to assist the user in the installation of post-202 manufactured VFDs for use on the SlideDriver
More informationThe Do s and Don ts of Pressure Transducers
The Do s and Don ts of Pressure Transducers ABSTRACT When specifying a pressure transducer for a process measurement, a number of items have to be considered. Some of the more important ones are discussed
More informationSERVING THE DEWATERING MARKETS
ELECTRIC ELECTRIC SERVING THE DEWATERING MARKETS ABOUT MODY, INC..... The Initial Start in India. The roots of Mody Pumps, Inc. began in India in 1957, almost 5 years ago by D.N. Mody; a successful businessman
More informationADAPTER IECEx-ATEX, RNC, IP66 / 68, NICKEL PLATED BRASS
ADAPTER IECEx-ATEX, RNC, IP66 / 68, NICKEL PLATED BRASS Anamet IECEx-ATEX adapter fitting, type RNC and RAC, nickel plated brass Type RNC IECEx-ATEX approved 45 or 90 nickel plated brass adapter, male
More informationInstallation, operation and service manual BMA 04
BMA 04 Please read this manual carefully before installing and using the BMA 04 safe measuring coupling. Wigersma & Sikkema warranty obligations do not apply in case of non-observance of this manual. 1
More informationThe Custom Interconnect Leader
QC Series 1.24 (31.5) 0.93 TYP (23.6) 0.180 (4.6) 0.413 (10.5) 0.112 (2.8) Figure 1: Standard 1.25" Mounting ELECTRICAL Nominal Impedance: Frequency Range: Voltage Rating: Dielectric Withstanding Voltage:
More informationAreamaster 250/400 Integrally Ballasted Floodlights 100 W to 400 W HID For hazardous and marine locations.
Lighting HID NEC/CEC ENCLOSED AND GASKETED CLASS/ZONE RATED FLOODLIGHT Applications Powerful, efficient weatherproof lighting for medium and large areas such as: Pulp and paper mills Processing plants
More informationBronze Parallel, Cross, and Bar Taps TYPE DGF, DGG. Ordering Information. or Copper Grounding Connector
TYPE DGF, DGG Copper Grounding Connector Copper grounding connector for cable to structural steel, fence posts or groundplates. DGF accommodates two conductors and DGG accommodates one conductor. L L S
More informationInstallation, operation and service manual BMA 05
BMA 05 Please read this manual carefully before installing and using the BMA 05 safe measuring coupling. Wigersma & Sikkema warranty obligations do not apply in case of non-observance of this manual. 1
More informationPreparation and Installation of the SANITRX / SANITRX LP (IS) Rupture Disc for Use With Industry Standard Ferrules
Preparation and Installation of the SANITRX / SANITRX LP (IS) Rupture Disc for Use With Industry Standard Ferrules GEP-6063 Rev. T 102335 Ref. I.D.: 12978 WARNING USER SHOULD READ AND THOROUGHLY UNDERSTAND
More informationTECHNICAL CHARACTERISTICS BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS
LE GLNS able glands and plastic accessories Regulatory ompliance: able Glands: EN 50262; IE 62444 Metric pitch: IE/EN 60243 PG pitch: IN 40430 ouplings and cable glands: EN 61386-1 e EN 60670-1 as applicable
More informationBMA 85 SERIES SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
BMA 85 SERIES SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE MECHANICAL MATERIALS: Bodies: Stainless Steel Per ASTM-A-582 Contacts: Beryllium Copper Per ASTM-B-196 Insulators: Teflon (PTFE) Per ASTM-D-1457
More informationApplications. Projected Area: 1.9 Sq. Ft. Dimensions in Inches/Millimeters
NEC/CEC: Applications Powerful, efficient weatherproof lighting for medium and large areas such as: Shopping malls Parking lots Sports areas New-car lot lighting Security lighting Industrial process lighting
More informationMOTOR STARTING AUTOTRANSFORMERS
SCTION 5 MOTOR STARTING AUTOTRANSFORMRS Copper Wound Two Coil and Three Coil escription and Applications... 144 Copper Standard Specifications... 145 imensional rawings... 145 Copper, Three Phase, 2 Coil
More informationDURASEAL. High Integrity, Double Block and Bleed Plug Valve.
DURASEAL High Integrity, Double Block and Bleed Plug Valve www.franklinvalve.com How the DuraSeal Works An improved valve with a proven history We took an alternative path. Unlike many valve manufacturers
More informationStandard VPX Cable Accessories
Standard VPX Cable Accessories 14 June 2010 rev 8 Brief 1 Cable Assemblies page 1 Elma p/n MG06X1OO04SS01 MG06X1EE04SS01 MG06X1OE04SS01 Description Odd to Odd Wafer/4 Lns Coax/ 6 x1 double ended Even to
More informationKnee for Aspiration Mk 2 User Guide
Knee for Aspiration Mk User Guide Designed and manufactured by Limbs & Things Limited, Sussex Street, St. Philips, Bristol, BS 0RA, UK. Telephone: +44 (0)7 0500 Fax: +44 (0)7 050 sales@limbsandthings.com
More informationSWITCHGEAR PBD. fuse bases
SWITCHGEAR PBD fuse bases designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links ENERGY SAFELY SWITCHED SWITCHGEAR
More informationSWITCHGEAR PBD. fuse bases
SWITCHGEAR PBD fuse bases designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links ENERGY SAFELY SWITCHED SWITCHGEAR
More information747 Series Stopper Plugs Cable Gland Accessories Flameproof.
747 Series Stopper Plugs Flameproof. Class I, Groups, A, B, C, D Type 4X; Ex d II Component Equipment Stopper plug is designed for use from the outside of the Idea for use on flameproof electrical equipment
More informationFAST1 Intraosseous Infusion System. Training Session
FAST1 Intraosseous Infusion System Training Session Why IO? Peripheral IV is often difficult to obtain Requires an average of 3-12 minutes Failure rate ranges between 10-40% AHA & ILCOR guidelines now
More informationMagnum. PRO Semiautomatic Guns
Magnum Processes MIG, Pulsed MIG, Flux-Cored Product Number K265-x Magnum PRO 0 K2652-x Magnum PRO 350 K2653-x Magnum PRO 450 K2655-x Magnum PRO 550 ACCESSORIES PRO Semiautomatic Guns Amperage Rating @
More informationMEDICAL CORPORATION Asbury Rd., P.O. Box 758, Farmingdale, NJ USA Fax
MEDICAL CORPORATION 5206 Asbury Rd., P.O. Box 758, Farmingdale, NJ 07727 USA 732-938-2266 800-323-4035 Fax 732-938-2399 MYO/WIRE Temporary Cardiac Pacing Wire System MYO/WIRE temporary cardiac pacing wires.
More informationCSA Z32 TESTING GUIDELINE AND PROCEDURES
CSA-Z32 Testing CSA Z32 TESTING GUIDELINE AND PROCEDURES Table of Contents CSA Z32 TESTING GUIDELINE AND PROCEDURES...1 Table of Contents...1 FACILITIES REQUIRED TO MEET CSA Z32:...1 TEST #1: INSULATION
More informationINSTRUCTION MANUAL LEG PRESS (NEW MODEL) OPTION OF K2 GYM
INSTRUCTION MANUAL LEG PRESS (NEW MODEL) OPTION OF K2 GYM QUESTION? As a quality home gym supplier we are committed to your complete satisfaction. If you have questions, or find missing or damaged parts,
More informationSECTION B ELECTRICAL/MECHANICAL LUGS & NEUTRAL BARS
1850 ilson Avenue, Toronto, Ontario, Canada, M9M 1A1 Ph: 416-741-7336 Fax: 416-741-9104 SECTION B EECTRICA/MECHANICA UGS & NEUTRA BARS B1 Electrical and Mechanical ug Overview and Numbering System B2-B3
More informationTHS74/75 Industrial Temperature & Humidity Transmitter. Operation Manual
THS74/75 Industrial Temperature & Humidity Transmitter Operation Manual 1. Features 2. Security considerations 3. Installation 4. Connection 5. Display and LED instruction 6. Software setting and calibration
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS CC34, B32, & C32 FOOD PROCESSORS CC34 B32 C32 FORM 43143 Rev. B (May 2016) F-43143 Rev. B (May 2016) - 2-2016 Table of Contents 5 FEED HEAD AND HOUSING 7 ELECTRICAL COMPONENTS
More informationInstallation Instructions
Installation Instructions 1View Manager 96 Enhanced OUCH RACKER Contents About his Document...1 Planning the OUCH RACKER Network...1 Backbone Network Guidelines...2 Star Network Guidelines...2 Installing
More information3. Dimensions, weights Placement and Assembly Pressure drops Noise data Material... 14
These technical specifications state a row of manufactured sizes and models of smoke extraction dampers - single (further only dampers) SEDS-L. It is valid for production, designing, ordering, delivery,
More informationHeight* FC width Prep depth RC width 4.0mm+ 4.3mm N/A 6.3mm
STERN ERA IMPLANT ABUTMENT Summary Resilient precision overdenture attachment. Universal hinge with vertical movement. Titanium abutment, nylon male. Manufactured for most popular screw and cylinder implants.
More informationTECH 2 Dew Point Retrofit Kit
TECH 2 Dew Point Retrofit Kit THORESON McCOSH TECH II Instruction Manual 412765A THORESON-McCOSH INC 1885 Thunderbird St. Troy MI. 48084 Phone 1-248-362-0960 Fax 1-248-362-5270 sales@thoresonmccosh.com
More informationUniversal Bussed Gutters, Amp Bussed Gutters for TB/MTB Units, Amp Termination Enclosures, Amp...
Universal Bussed Gutters, 400-2000 Amp........................................... 49-50 Bussed Gutters for TB/MTB Units, 400-800 Amp................................... 51-52 Termination Enclosures, 100-1200
More informationTABLE OF CONTENTS. 2.0 USING MANAGER PREFERENCE 2.1 Using manager preference mode 2.2 Selecting US or metric 2.3 Using CSafe
E L L I P T I C A L T O T A L B O D O W N E R S M A N U A L TABLE OF CONTENTS 1.0 IMPORTANT SAFET INSTRUCTIONS Read and save these instructions Setting up the Elliptical total body 1.1 Installation requirements
More informationBase S D T B
SD-00/000 RoHS compliant INTERNAL STRUCTURE SD-00 / 000 series 3 6 7 5 FEATURES RoHS compliant Fine click with metallic spring Low profile of 3.9 mm makes perfect for high density board mounting applications
More informationTEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP
TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...
More informationTEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP
TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL 1 2 Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...
More informationProcess lock Dalton. Use: Features: Door and hatches
Process lock Dalton Use: Door and hatches Features: Small and robust Integrated with Eden High enclosure classification IP Withstands harsh enviroments Low current consumption Status information with LED
More informationTEKNOCRAFT INC. Proportional Valves. Mini Valves. Outlet Balanced Valves. Standard Valves. Your Proportional Valve Specialists
TEKNOCRAFT INC. Your Proportional Valve Specialists Proportional Valves Mini Valves Outlet Balanced Valves Standard Valves Table of Contents Teknocraft Unique Designs... 3 Mini Valves... 6 Outlet Balanced
More informationPROFIBUS DP cables. 1 Order data. PROFIBUS DP cables. Table 1: X67CA0Bxx PROFIBUS DP cables - Order data. Data sheet V
PROFIBUS DP cables 1 Order data, model number Length PROFIBUS DP connection cable PROFIBUS DP attachment cable PROFIBUS DP open-ended cable 2.0 m X67CA0B02.0020 X67CA0B12.0020.0 m X67CA0B02.000 X67CA0B12.000
More informationMS/Standard B - Class
MS/Standard B lass mphenol R mphenol ML5015 onnectors MS B lass MSB class connector is a general duty standard cylindrical connector. t is a widely used for the automotive machine tool & welding industries,
More informationChapter 5: Checking and Maintaining Ultrasound Equipment
Chapter 5: Checking and Maintaining Ultrasound Equipment Care and Cleaning (BB1564-AJ) Chapter 5: Checking and Maintaining Ultrasound Equipment 45 Ultrasound equipment requires regular checks and maintenance.
More informationGeschrieben von: Yadira Jones
Brother PT-1290 LCD Screen Replacement When the LCD becomes damaged, it makes it hard to utilize this device, so here is a guide that will walk you through the process of replacing it and resume your printing
More informationInstrumentation Cables
Instrumentation Cables Introduction....2 300 V PVC Insulated, PVC Jacketed PLTC/ITC Rated Applications and Description....3 Overall Shielded Pairs....4 Overall Shielded Triads...5 Individual and Overall
More informationMS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type
ABB Manual Motor Starter General Information Extended Product Type Product ID 1SAM250000R1008 EAN 4013614320316 Catalog Description Long Description Manual Motor Starter The manual motor starter (also
More informationCompressor Accessories
Compressor Accessories Series 11 Superior quality for superior performance COMPRESSOR OIL Description MINERAL 11.1100 1 litre container 11.1400 4 litre container SYNTHETIC 11.1200 1 litre container 11.1500
More informationUSER'S MANUAL QUESTIONS? Mon. Fri., 6 a.m. 6 p.m. MST CAUTION. Visit our website at.
Model No. DRTL5940 Serial No. USER'S MANUAL Serial Number Decal QUESTIONS? If you have questions, or if there are missing or damaged parts, we will guarantee complete satisfaction through direct assistance
More informationProduct Catalog. Since 1985» Simple. Predictable. Profitable.
Product Catalog Since 1985» Simple. Predictable. Profitable. 2011 IMPLANTS 3.0mm Well Integra-CP Part No. DIAMETER LENGTH 345-306 4.5mm 6.0mm 345-308 4.5mm 8.0mm 345-311 4.5mm 11.0mm 350-305 5.0mm 5.0mm
More informationINSTRUMENTATION. 300 Volt and 600 Volt Cables LEAD FREE O V E R Y E A R S O F E X P E R I E N C E. w w w. n e x a n s e n e r g y.
INSTRUMENTATION 300 Volt and 600 Volt Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Instrumentation Cables Introduction....2 300 V
More informationCanon Powershot A70 Button Flex Assembly Replacement
Canon Powershot A70 Button Flex Assembly Replacement Geschrieben von: Brian ifixit CC BY-NC-SA de.ifixit.com Seite 1 von 15 EINLEITUNG This guide will walk through the process of removing the button flex
More informationSide Channel R ing Blower
Side Channel R ing Blower ------------------------------------- INSTRUCTION MNUL ------------------------------------ RB20../ 30../ 40../ 50../ 60 / 80.. SERIES CONTENT PGE 1. SFETY REQUIREMENT... 1 2.
More informationKnee for Aspiration Mk2
User Guide Knee for Aspiration Mk Part No: 6060 Part No: 065-05 Issue, June 04 04 Limbs & Things For more skills training products visit limbsandthings.com Limbs & Things Ltd. Sussex Street, St Philips
More informationWhaT s included. gun requires. Gun Connector Kit Gun Liner
Magnum Processes MIG, Pulsed MIG, Flux-Cored Product Number K265-x Magnum PRO 0 K2652-x Magnum PRO 350 K2653-x Magnum PRO 450 K2655-x Magnum PRO 550 ACCESSORIES pro semiautomatic guns Amperage Rating @
More informationPremium Chemical Free Iron/Sulphur Filter Installation Manual
Premium Chemical Free Iron/Sulphur Filter Installation Manual 220 Bayview Avenue Unit 18 Barrie, Ontario, Canada, L4N 4Y8 www.excaliburwater.com EXCALIBUR PREMIUM CHEMICAL FREE IRON/SULPHUR FILTER INSTALLATION
More informationX [dream] Gebrauchsanweisung User manual
X [dream] Gebrauchsanweisung User manual English 09 10 Copyright 2015. StattQualm GmbH SQuape is a registered trademark of StattQualm GmbH in Switzerland and/or other Countries. Table of contents 1. Description
More informationENGINEERED ELASTOMER SOLUTIONS FOR VEHICLE SYSTEMS DESIGN
Automotive and Transportation Consumer Solutions ENGINEERED ELASTOMER SOLUTIONS FOR VEHICLE SYSTEMS DESIGN Smart science drives component durability innovation Cover Footer (optional)-dow Corporate-Bold-9/12+White
More informationReplacement Parts for Raymond 102XM Walkie
Replacement Parts for Contents Quick Wheel Lookup Electrical System Components Battery Connector, Motor Controllers 6 Drive Unit Drive Motor Parts, Brake Assembly 8 Control Handle Arm, Throttle Assembly
More informationPB PMA Series Attachment BASE Attachment Plate model Applicable models F-PBA10-1 F-PBA15-1 F-PBA30-1 F-PBA50-1 F-PBA75-1 F-PBA100-1 F-PBA150-1
al Parts PB PMA Series Attachment BASE Attachment Plate model Applicable models F-PBA0- F-PBA- F-PBA0- F-PBA0- F-PBA- F-PBA00- F-PBA0- PBA0F PBAF, PBWF PBA0F, PBW0F, PMAF PBA0F, PBW0F, PMA0F PBAF, PMA0F
More informationAnchorage system. tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282
tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282 266 . innovative comprehensive efficient. Dentaurum Online Shop shop.dentaurum.com
More informationIECEx Certificate of Conformity CESI
Description of the equipment: Luminaries (pendant lighting fixtures) series EV.., EW.., EWA.., are used in hazardous area, indoor and/or outdoor, where inflammable or explosive vapours gas or dust are
More informationFendall Pure Flow 1000 eyewash station, English Ea
Requirements specify that... suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area... Visit www.osha.gov for complete details and regulation requirements.
More informationOT EQUATOR CASTABLE Single Attachment for Overdentures
OT EQUATOR CASTABLE Single Attachment for Overdentures pick-up impression OT EQUATOR PROFILE CASTABLE MALE ATTACHMENT individual tray RETENTIVE CAPS OT EQUATOR HOUSING VIOLET CAP RIGID RETENTION (2.7Kg)
More informationGeschrieben von: Mark
DualShock 4 Touch Pad Replacement Remove the touchpad on the Dualshock 4 controller. Geschrieben von: Mark ifixit CC BY-NC-SA de.ifixit.com Seite 1 von 9 EINLEITUNG Use this guide to remove a defective
More informationGeschrieben von: Valentina Cerruty
Wii U GamePad LCD Display Replacement Replace the LCD display in order to fixed the broken LCD display Geschrieben von: Valentina Cerruty ifixit CC BY-NC-SA de.ifixit.com Seite 1 von 13 EINLEITUNG This
More informationSURETEST Torque Calibration System
SURETEST TM The SURETEST is a laboratory grade instrument which captures torque measurements with a user friendly interface. It features a large LCD graphical display. It may be used with a single transducer
More informationSurgical Technique. Targeter Systems Overview
Surgical Technique Targeter Systems Overview PERI-LOC Locked Plating System Targeter Systems Overview Table of contents Product overview... 2 Introduction... 2 Indications... 2 Design features and benefits...
More informationTechnical support: +49 (0)7223 /
ISO 9001 certified Technical support: +49 (0)7223 / 9493-0 Technical description ADDIVARIOUS PX 901 Screw terminal board 8 th edition 08/2000 Copyright All rights reserved. This manual is intended for
More informationcomponents IC, PB PSCK Pressure switches Digital pressure gauges Pressure gauges GA, GS NV, FM Gauge accessories A, AH/R HLS, H, T
Pressure switches t series IC, PB PSCK t page 188 Digital pressure gauges DG 189 Pressure gauges Gauge accessories Manifolds, couplers, hoses, tubing G GA, GS NV, FM A, AH/R HLS, H, T 190 191 192 High
More informationSED2 VFD NEMA Type 3R Bypass, and Type 3R Harsh Environment (3RHE) Bypass
Document No. 129-405 SED2 VFD NEMA Type 3R Bypass, and Type 3R Harsh Environment (3RHE) Bypass Product Description The SED2 VFD NEMA Type 3R/3RHE, Bypasses are companion packages for the family of SED2
More informationA-dec 372L or 572L Dental Light on an A-dec Performer Dental Chair INSTALLATION GUIDE
A-dec 37L or 57L Dental Light on an A-dec Performer Dental Chair INSTALLATION GUIDE Contents Before You Begin.......... Remove the Covers........ Choose the Procedure...... 3 Install the Rigid Arm.......
More informationENERGY EFFICIENT DISTRIBUTION TRANSFORMERS
ENERGY EFFICIENT GENERAL PURPOSE Low Voltage DISTRIBUTION TRANSFORMERS 600V Class, Single Phase & Three Phase Low Voltage Distribution Transformer Energy Efficiency Guidelines U.S.A... 154 Low Voltage
More information(12) Patent Application Publication (10) Pub. No.: US 2014/ A1
(19) United States (12) Patent Application Publication (10) Pub. No.: US 2014/0287886 A1 Patti US 20140287886A1 (43) Pub. Date: Sep. 25, 2014 (54) (71) (72) (21) (22) (60) PROTECTOR FOR EXERCISE BAR Applicant:
More informationQuick Sealing with a Twist to Connect Actuation Method
- Finger tighten seals up to 689 bar (10,000 psi) for pneumatic and hydraulic testing - Safe and Reliable leak tight connections to male and female threads - Eliminate thread damage, sealant and wrenches
More informationProduct Specifications and Usage Information P4405, P4410, & P4420 Genesys 30 Dosimeter Holder System
DESCRIPTION The Thermo Genesys 30 Spectrophotometer (G30) is supplied with specially designed dosimeter holders to fit a variety of dosimeters, including the B3 DoseStix and B3 WINdose dosimeters. The
More informationGT350 Red Starter Button Kit M-10B776-MR
Please visit www.fordracingparts.com for the most current instruction and warranty information. PLEASE READ ALL OF THE FOLLOWING INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION. AT ANY TIME YOU DO NOT UNDERSTAND
More informationAsus Zenfone 2 Display Assembly
Asus Zenfone 2 Display Assembly Replacement Step by step tear-down and replacement of display assembly. Geschrieben von: zacxzac ifixit CC BY-NC-SA de.ifixit.com Seite 1 von 15 EINFÜHRUNG Step by step
More informationMacBook Pro 15" Core 2 Duo Models A1226 and A1260 ExpressCard Cage Replacement
MacBook Pro 15" Core 2 Duo Models A1226 and A1260 ExpressCard Cage Replacement Geschrieben von: Walter Galan ifixit CC BY-NC-SA de.ifixit.com Seite 1 von 15 EINLEITUNG You can again use ExpressCard accessories
More informationFasMate Quick Connectors Industry Applications:
FasMate Quick Connectors Industry Applications: The FasMate Series instantly seals threaded ports from vacuum up to 344.7 bar. The patented proprietary design makes sealing threaded ports as easy as 1,
More information1 Service factor Determine the required service factor from tables 9 and 10 on pages 87 and 88.
SKF Couplings SKF Flex Couplings SKF Flex Couplings are designed to accommodate misalignment and shock loads and dampen vibration levels. These easy to install, maintenance-free couplings are available
More informationS202M-K2UC. Miniature Circuit Breaker - S200MUC - 2P - K - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.
ABB Miniature Circuit Breaker - S00MUC - P - K - ampere General Information Extended Product Type Product ID S0M-KUC CDS7061R077 EAN 4013614433146 Catalog Description Long Description Miniature Circuit
More informationSDS 4.0 Reference Guide
SDS 4.0 Reference Guide Content Important information 2 SDS 4.0 Fit and Go Box overview 3 Selecting the receiver length 4 Choosing the correct earpiece for the receiver 5 Attaching / removing the retention
More informationMeter Equipment Group
Metering Mounting Equipment MTRFLA-17 B-LINE SERIES Meter Equipment Group Table of contents Introduction... 1 Table of Contents... 2 Single Meter Sockets - Without Bypass 125 & 200 Amp... 4-5 Single Meter
More informationV New HGP 20. Standard grippers 7.5. Economical and versatile. Self centring. Choice of gripping action. Standard grippers.
V New HGP 20 Economical and versatile Self centring Choice of gripping action 2004/10 Subject to change Products 2004/2005 1 / 1 Key features HGD HGP 06 HGP... B HGR HGW System product for handling and
More information