1 The Ceterix NovoStitch Disposable Suture Passer Ceterix Orthopaedic cs 959 Hamilton Avenue Menlo Park, CA Customer Service: (650) IK D i Sterile Do Not Reusee See Instructions for Use THE CETERIX NOVOSTITCH DISPOSABLE SUTURE PASSER CAUTION: Federal law restricts this device to sale by or on the order of a physician. DESCRIPTION The Ceterix NovoStitch Disposable Suture Passer device is an arthroscopicc suture passer designed to pass USP size 2 0 or 0 braided surgical suture through soft tissue in arthroscopic surgery. The device has a diameter less than 6..5mm. The needle is retractable. INDICATION FOR USE The device is indicatedd for passing suture through soft tissue in orthopaedic surgery. CONTRAINDICATIONS The device is not to be used on bone or other hard tissue. P/N: LBL 0012 Rev: A Page 1

2 WARNINGS 1. Whether used arthroscopically or open surgery, the device must be used under direct visualization. 2. Do not force the device into tight joint spaces. Excessive pushing, twisting or levering may cause breakage. 3. Do not force the upper jaw open or closed. 4. Do not force the lower jaw into position. PRECAUTIONS This device should be used only by physicians with a thorough understanding of arthroscopic procedures. The device is provided STERILE for SINGLE USE ONLY. This product is for single use only. It has not been designed to be re used or re sterilized. Reprocessing may lead to changes in material characteristics such as corrosion and dulled edges, which may impact the strength of the device and compromise performance. Reprocessing of single use devices can also cause cross contamination leading to patient infections. These risks may potentially affect patient safety. PREPARATIONS FOR USE Read the Instructions for Use in its entirety prior to use of the device. Inspect the device prior to use to ensure proper mechanical function. Figure 1: The Ceterix NovoStitch Disposable Suture Passer Lever C Lower jaw retractor Radiused upper jaw Sliding lower jaw (retracted position) Lever A Upper jaw lever Lever B Lower jaw / needle lever 1 st squeeze advances lower jaw. Squeezing with advanced lower jaw drives the needle. Page 2

3 DIRECTIONS FOR USE PASSING SUTURE THROUGH MENISCAL TISSUE 1. Select USP size 2 0 or 0 braided suture and have available in the sterile field along with the device. CAUTION: Do NOT use suture other than braided USP size 2 0 or Suture Loading: Carefully follow these steps to ensure correct suture loading. a. Advance the lower jaw by holding the pistol grip (without Lever A) and squeezing Lever B until the lower jaw is fully advanced (see Figure 2). Figure 2: Fully advanced lower jaw. b. Load approximately 6 of one suture end into the lower jaw slot. Grab the short strand and the remaining suture, forming a loop around the left tine of the lower jaw. Pull the loop proximally (see Figure 3). Figure 3: Form a loop around the left tine of the lower jaw. Page 3

4 c. While maintaining proximal tension on the loop, slightly squeeze Lever B so that the needle moves forward about 1 mm (see Figure 4), then release Lever B. Do not fully advance Lever B at this stage. The suture strand will be locked in the lower jaw by the needle. Figure 4: Slightly squeeze Lever B to advance needle approximately 1mm. d. Retract the lower jaw by pushing down on Lever C (see Figure 1), the lower jaw retractor. e. The suture is now loaded for passing suture through soft tissue. 3. With the suture loaded and the lower jaw in the retracted position, pass the device into the surgical site under arthroscopic visualization. 4. Advance the upper jaw along the superior surface of the meniscus following the radius of the femoral condyle. 5. When the upper jaw is in position, fully advance the lower jaw by squeezing Lever B (see Figure 1 above) without squeezing Lever A, the upper jaw lever. Ensure that the lower jaw slides underneath the meniscus and release Lever B. 6. When both upper and lower jaws are in position, deploy the needle and suture limb by simultaneously squeezing Levers A and B (see Figure 1 above) until Lever B is fully advanced. The suture outside of the access port should be observed advancing in tandem with the needle trigger advancement. If the suture does not advance, or if the suture breaks, the suture may be pinched between the device and the surrounding structures. If this occurs, consider adjusting the patient position before redeploying the needle. 7. Release both Levers A and B and then retract the lower jaw by pushing down Lever C. Carefully remove the device from the joint. Remove the suture end from the upper jaw by pulling in the proximal direction. Page 4

5 8. If needed, repeat steps 2 through 7 using the opposing suture end. This will create a circumferential stitch. 9. Using standard surgical techniques and a commercially available knot pusher, advance a knot to the surface of the tissue until tissue approximation at the tear is observed. Place the appropriate number of additional throws to ensure that the knot is secure. 10. Using a commercially available arthroscopic suture cutter, trim the suture limbs from the knot. 11. Bench deployment testing has demonstrated that the device can be reloaded with suture and fully actuated 14 times. Cycling the device in excess of 14 deployments may impact needle integrity and compromise performance. 12. Immediately discard the Ceterix NovoStitch Disposable Suture Passer after completion of the surgery. The device is SINGLE USE ONLY. STORAGE Store in a cool, dry area. Page 5

The Ceterix NovoStitch Disposable Suture Passer. Do Not Reuse

The Ceterix NovoStitch Disposable Suture Passer. Do Not Reuse The Ceterix NovoStitch Disposable Suture Passer Ceterix Orthopaedics 959 Hamilton Avenue Menlo Park, CA 94025 Customer Service: (650) 241-1748 IK Sterile D Do Not Reuse i See Instructions for Use THE CETERIX

More information

Arthroscopic Meniscal Repair using the Meniscal Cinch Surgical Technique

Arthroscopic Meniscal Repair using the Meniscal Cinch Surgical Technique Arthroscopic Meniscal Repair using the Meniscal Cinch Surgical Technique Arthroscopic Meniscal Repair Small PEEK implants and 2-0 FiberWire provide secure, low profile fixation Slotted, curved cannula

More information

CrossFix II. All-Suture, All-Inside Meniscal Repair System. Surgical Technique

CrossFix II. All-Suture, All-Inside Meniscal Repair System. Surgical Technique CrossFix II All-Suture, All-Inside Meniscal Repair System Surgical Technique 3 CrossFix II All- Suture Repair System Surgical Technique All-Inside Repair with Inside-Out Results The CrossFix II Meniscal

More information

Visit Linvatec.com today to learn more. Surgical Technique: Sequential Meniscal Running Stitch

Visit Linvatec.com today to learn more. Surgical Technique: Sequential Meniscal Running Stitch ORDERING INFORMATION Sequent Meniscal Repair System MR004S MR007S MR004C MR007C SC047D Straight Needle, 4 Implants Straight Needle, 7 Implants Curved Needle, 4 Implants Curved Needle, 7 implants Sequent

More information

OMNISPAN MENISCAL REPAIR SYSTEM Prominent in Strength, Subtle in Profile

OMNISPAN MENISCAL REPAIR SYSTEM Prominent in Strength, Subtle in Profile OMNISPAN MENISCAL REPAIR SYSTEM Prominent in Strength, Subtle in Profile This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE The OMNISPAN Meniscal Repair System from DePuy

More information

Arthroscopic Shoulder Repair Using the Smith & Nephew KINSA Suture Anchor

Arthroscopic Shoulder Repair Using the Smith & Nephew KINSA Suture Anchor Shoulder Series Technique Guide *smith&nephew KINSA Suture Anchor Arthroscopic Shoulder Repair Using the Smith & Nephew KINSA Suture Anchor Reviewed by: Larry D. Field, MD Mississippi Sports Medicine and

More information

CHANGING THE WAY YOU LOOK AT THINGS

CHANGING THE WAY YOU LOOK AT THINGS CHANGING THE WAY YOU LOOK AT THINGS At ConMed Linvatec, we re constantly challenging ourselves to develop truly innovative arthroscopic products that not only complement your technique, but also lead to

More information

BIOKNOTLESSRC ROTATOR CUFF REPAIR SUTURE ANCHOR SURGICAL TECHNIQUE. Surgical Technique for Arthroscopic Rotator Cuff Repair. Raymond Thal, M.D.

BIOKNOTLESSRC ROTATOR CUFF REPAIR SUTURE ANCHOR SURGICAL TECHNIQUE. Surgical Technique for Arthroscopic Rotator Cuff Repair. Raymond Thal, M.D. SURGICAL TECHNIQUE ROTATOR CUFF REPAIR BIOKNOTLESSRC SUTURE ANCHOR Surgical Technique for Arthroscopic Rotator Cuff Repair Raymond Thal, M.D. Town Center Orthopaedic Associates Reston, Virginia Surgical

More information

GENERAL TECHNIQUE GUIDE

GENERAL TECHNIQUE GUIDE GENERAL TECHNIQUE GUIDE PRODUCT OVERVIEW The Eclipse Soft Tissue Anchor employs MedShape s shape memory PEEK Altera technology for soft tissue fixation procedures in the shoulder, elbow, knee, hand & wrist,

More information

Single Use Curlew TM Multiple Biopsy Forceps

Single Use Curlew TM Multiple Biopsy Forceps Single Use Curlew TM Multiple Biopsy Forceps 13 SPECIMEN WITH METAL STORAGE CYLINDER With In Situ Fixation, Batch or Single Specimen Collection US Patents 5,782,747; 5,980,468; 6,071,248; foreign patents

More information

Surgical Protocol written by Keith Lawhorn, M.D.

Surgical Protocol written by Keith Lawhorn, M.D. Surgical Protocol written by Keith Lawhorn, M.D. The MaxFire Meniscal Repair System is an all-inside, all-suture meniscal repair system utilizing ZipLoop Technology. Anchors are preloaded on needle inserters,

More information

RD180 SP TECHNOLOGY GUIDE READ THIS PRODUCT INSERT THOROUGHLY BEFORE USE

RD180 SP TECHNOLOGY GUIDE READ THIS PRODUCT INSERT THOROUGHLY BEFORE USE RD180 SP TECHNOLOGY GUIDE READ THIS PRODUCT INSERT THOROUGHLY BEFORE USE FIG. 1 RD180 SP - THE RUNNING DEVICE 1 2 6 3 7 4 5 1 NEEDLE 2 FERRULE 3 SUTURE 4 DEVICE TIP 5 ANGLED SHAFT 6 HANDLE 7 PINK LEVER

More information

Technique Guide. *smith&nephew N8TIVE ACL Anatomic ACL Reconstruction System

Technique Guide. *smith&nephew N8TIVE ACL Anatomic ACL Reconstruction System Technique Guide *smith&nephew N8TIVE ACL Anatomic ACL Reconstruction System N8TIVE ACL System The N8TIVE ACL Anatomic Reconstruction System provides a novel and simple approach to ACL repair. The N8TIVE

More information

MULTIFIX S Knotless Implants

MULTIFIX S Knotless Implants Technique Guide MULTIFIX S Knotless Implants The MULTIFIX S system offers 5.5mm and 6.5mm knotless, all-peek, poundin implants. The system provides multiple fixation options, a streamlined technique, and

More information

Echo PS Positioning System with Ventralight ST Mesh or Composix L/P Mesh

Echo PS Positioning System with Ventralight ST Mesh or Composix L/P Mesh Ventralight ST Mesh with Echo PS Positioning System Catalog Number Shape Mesh Size 5955450 Circle 4.5" (11.4 cm) 5955460 Ellipse 4" x 6" (10.2 cm x 15.2 cm) 5955600 Circle 6" (15.2 cm) 5955680 Ellipse

More information

Technique Guide. *smith&nephew SPEEDSCREW Fully Threaded Knotless Implant

Technique Guide. *smith&nephew SPEEDSCREW Fully Threaded Knotless Implant Technique Guide *smith&nephew SPEEDSCREW Fully Threaded Knotless Implant SPEEDSCREW system Fully threaded knotless implant system The SPEEDSCREW system is specifically designed for rotator cuff repair

More information

Technique Guide. *smith&nephew MAGNUM 2 Knotless Implant

Technique Guide. *smith&nephew MAGNUM 2 Knotless Implant Technique Guide *smith&nephew MAGNUM 2 Knotless Implant MAGNUM 2 knotless implant The MAGNUM 2 implant increases surgeon control by combining independent cortical bone lock, suture lock, and incremental

More information

Extracapsular Repair Monofilament Nylon Suture

Extracapsular Repair Monofilament Nylon Suture Extracapsular Repair Monofilament Nylon Suture Management of the ruptured Cranial Cruciate Ligament (CCL) by placing a non-absorbable suture between the lateral fabella and the proximal, cranial tibia

More information

Directions For Use. All directions should be read before use

Directions For Use. All directions should be read before use Directions For Use All directions should be read before use DEVICE DESCRIPTION: The CLEANER.XT Rotational Thrombectomy System is a percutaneous, 6Fr catheter based system (single piece construction) that

More information

DEVELOPED BY MEDSHAPE, INC. IN CONJUNCTION WITH PATRICK ST. PIERRE, M.D. BICEPS TENODESIS ARTHROSCOPIC AND SUBPECTORAL SURGICAL TECHNIQUE

DEVELOPED BY MEDSHAPE, INC. IN CONJUNCTION WITH PATRICK ST. PIERRE, M.D. BICEPS TENODESIS ARTHROSCOPIC AND SUBPECTORAL SURGICAL TECHNIQUE ! SURGICAL TECHNIQUE! DEVELOPED BY MEDSHAPE, INC. IN CONJUNCTION WITH PATRICK ST. PIERRE, M.D. ARTHROSCOPIC AND SUBPECTORAL BICEPS TENODESIS SURGICAL TECHNIQUE BICEPS TENODESIS Indications Tenodesis of

More information

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE INDICATIONS FOR USE The LATERA Absorbable Nasal Implant is indicated for supporting upper and lower lateral nasal cartilage. CAUTION: Federal law restricts

More information

Chart a course for meniscal preservation

Chart a course for meniscal preservation Chart a course for meniscal preservation 1 The clearly defined value of meniscal preservation A number of studies have been published that clearly define the benefits of preserving as much functional meniscus

More information

Nit-Occlud. Coil System for PDA Closure IMPLANTATION POCKET GUIDE. Rx only CV / B. Braun Interventional Systems Inc.

Nit-Occlud. Coil System for PDA Closure IMPLANTATION POCKET GUIDE. Rx only CV / B. Braun Interventional Systems Inc. Refer to the Nit-Occlud PDA Instructions for Use for relevant warnings, precautions, complications and contraindications. This device has been designed for single use only. Nit-Occlud Coil System for PDA

More information

Rotator Cuff Repair using JuggerKnot Soft Anchor 2.9mm Surgical Technique

Rotator Cuff Repair using JuggerKnot Soft Anchor 2.9mm Surgical Technique Rotator Cuff Repair using JuggerKnot Soft Anchor 2.9mm Surgical Technique It s small. It s strong. And it's all suture. The JuggerKnot Soft Anchor represents the next generation of suture anchor technology.

More information

Device Preparation (all steps to be performed per standard interventional technique)

Device Preparation (all steps to be performed per standard interventional technique) sertera Biopsy Device Instructions for Use Please read all information carefully. Failure to properly follow the instructions may lead to unintended consequences. Important: This package insert is designed

More information

GRAVITY Plantar Plate Repair System SURGIC AL TECHNIQUE

GRAVITY Plantar Plate Repair System SURGIC AL TECHNIQUE GRAVITY Plantar Plate Repair System SURGIC AL TECHNIQUE Contents PREFACE Preface 4 4 5 5 Chapter 1 6 6 7 8 9 11 12 13 13 Appendix 14 Introduction Positioning Indications Contraindications Surgical Technique

More information

The AperFix II System

The AperFix II System The AperFix II System A Complete Anatomic Solution Transtibial Surgical Technique 2 AperFix II System Transtibial Surgical Technique Figure 1 A Complete Anatomic Solution The Cayenne Medical AperFix and

More information

Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter

Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter Caution: Federal (USA) law restricts this device to sale by or on the order of a physician. DEVICE DESCRIPTION

More information

Knee Preservation System

Knee Preservation System Knee Preservation System Sequential Meniscal Running Stitch Surgical Technique Multiple continuous stitches for repair of any size meniscal tear. COMMITTED TO INNOVATION SURGICAL TECHNIQUE The Sequent

More information

Technique Guide. MULTIFIX P PEEK 4.5mm Knotless Fixation Implant

Technique Guide. MULTIFIX P PEEK 4.5mm Knotless Fixation Implant Technique Guide MULTIFIX P PEEK 4.5mm Knotless Fixation Implant MULTIFIX P system With the ability to accommodate 2-4 suture strands and lock suture internally, the 4.5mm MULTIFIX P system gives the surgeon

More information

Cardiva Catalyst III INSTRUCTIONS FOR USE

Cardiva Catalyst III INSTRUCTIONS FOR USE Cardiva Catalyst III INSTRUCTIONS FOR USE IFU 2469 Rev. G CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. For single use only GRAPHICAL SYMBOLS ON THE CARDIVA

More information

Ponsky * PEG Safety System - "Pull" Bard * PEG Safety System - "Guidewire" Information for Use

Ponsky * PEG Safety System - Pull Bard * PEG Safety System - Guidewire Information for Use Ponsky * PEG Safety System - "Pull" Bard * PEG Safety System - "Guidewire" Information for Use Rx only Single patient use DEHP-Free This product and package do not contain natural rubber latex STERILE

More information

Velocity Orthopedics Instrument Cleaning and Sterilization

Velocity Orthopedics Instrument Cleaning and Sterilization Velocity Orthopedics Instrument Cleaning and Sterilization It is important to read the Instructions For Use in its entirety prior to using the product. Caution: Federal law (USA) restricts this device

More information

FIXED PERFORMANCE. Soft Tissue ACL Reconstruction

FIXED PERFORMANCE. Soft Tissue ACL Reconstruction ADJUSTABLE CONVENIENCE, FIXED PERFORMANCE Soft Tissue ACL Reconstruction Surgical Technique The RIGIDLOOP Adjustable Cortical System The RIGIDLOOP Adjustable Cortical System is an innovative technology

More information

Technique Guide KISSloc Suture System

Technique Guide KISSloc Suture System Technique Guide KISSloc Suture System The KISSloc Suture System consists of a strong self-cinching suture assembly, a unique load-dispersing Arrow Plate and procedure specific instrumentation. Simple,

More information

AFX. Femoral Implant. System. The AperFix. AM Portal Surgical Technique Guide. with the. The AperFix System with the AFX Femoral Implant

AFX. Femoral Implant. System. The AperFix. AM Portal Surgical Technique Guide. with the. The AperFix System with the AFX Femoral Implant The AperFix System AFX with the Femoral Implant AM Portal Surgical Technique Guide The Cayenne Medical AperFix system with the AFX Femoral Implant is the only anatomic system for soft tissue ACL reconstruction

More information

INSTRUCTIONS FOR USE AND CARE

INSTRUCTIONS FOR USE AND CARE DIAMONDS INSTRUCTIONS FOR USE AND CARE DIAMONDS, MULTI-USE, FRICTION GRIP Quala Diamonds are a rotary cutting device made of stainless steel and coated with diamond particles on the working end. It is

More information

ROTATOR CUFF REPAIR WITH STATAK SUTURE ANCHORS

ROTATOR CUFF REPAIR WITH STATAK SUTURE ANCHORS ROTATOR CUFF REPAIR WITH STATAK ANCHORS SURGICAL TECHNIQUES ARTHROSCOPIC & OPEN ARTHROSCOPIC TECHNIQUE 1 CANNULA PLACEMENT 2CREATE TROUGH 1 Anterior cannula 2 Lateral cannula 3 Posterior cannula 1 2 3

More information

ComposiTCP Anchor with BroadBand Tape

ComposiTCP Anchor with BroadBand Tape ComposiTCP Anchor with BroadBand Tape featuring Medial Row Knot Tying Surgical Technique 2 ComposiTCP Anchor with BroadBand Tape Surgical Technique Figure 1 Figure 2 Step 1 Place the ComposiTCP punch/tap

More information

Absorbable Woven Polyglycolic Acid Mesh Tube (Absorbable Nerve Conduit Tube) INSTRUCTIONS FOR USE 2 6

Absorbable Woven Polyglycolic Acid Mesh Tube (Absorbable Nerve Conduit Tube) INSTRUCTIONS FOR USE 2 6 Absorbable Woven Polyglycolic Acid Mesh Tube (Absorbable Nerve Conduit Tube) INSTRUCTIONS FOR USE 2 6 1 0086 SYMBOL DEFINITIONS ENGLISH Do not Reuse Consult Instructions For Use Ethylene Oxide Sterilized

More information

St. Jude Medical 8-Channel Adapter. Clinician's Manual

St. Jude Medical 8-Channel Adapter. Clinician's Manual St. Jude Medical 8-Channel Adapter Clinician's Manual CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician. For U.S. California Only: Proposition 65, a State of California

More information

Directions For Use. All directions should be read before use. Page 1 of 8

Directions For Use. All directions should be read before use. Page 1 of 8 Directions For Use All directions should be read before use Page 1 of 8 WARNING: For single use only. Do not reuse, reprocess or re-sterilize. Reuse, reprocessing or re-sterilization may compromise the

More information

Instructions for Use io-flex Probe

Instructions for Use io-flex Probe DEVICE DESCRIPTION: The is an accessory of the Amendia io-flex System, which includes the MicroBlade Shaver device. The io-flex Probe is designed to access the neural foramen. It is comprised of an outer

More information

SureLock All-Suture Anchor System

SureLock All-Suture Anchor System SureLock All-Suture Anchor System Guide for Bankart Repair Surgical Technique 2 SureLock All-Suture System Bankart Repair Surgical Technique Figure 1 *Curved and straight drill guides are available for

More information

Duraloc CONSTRAINED LINER

Duraloc CONSTRAINED LINER SURGICAL TECHNIQUE Duraloc CONSTRAINED LINER A COMPREHENSIVE ACETABULAR REVISION SYSTEM DURALOC CONSTRAINED LINER Introduction Dislocation is the most common postoperative complication in total hip reconstruction.

More information

Peel-Apart Percutaneous Introducer Kits for

Peel-Apart Percutaneous Introducer Kits for Bard Access Systems Peel-Apart Percutaneous Introducer Kits for Table of Contents Contents Page Bard Implanted Ports Hickman*, Leonard*, Broviac*, Tenckhoff*, and Groshong* Catheters Introduction....................................

More information

Subpectoral Biceps Tenodesis using Cortical Buttons Surgical Technique

Subpectoral Biceps Tenodesis using Cortical Buttons Surgical Technique Subpectoral Biceps Tenodesis using Cortical Buttons Surgical Technique Subpectoral Biceps Tenodesis Subpectoral Biceps Tenodesis using Cortical Buttons Introduction Subpectoral biceps tenodesis using cortical

More information

CLARIVEIN INFUSION CATHETER

CLARIVEIN INFUSION CATHETER CLARIVEIN INFUSION CATHETER General Product Description Overview The ClariVein Infusion Catheter (ClariVein -IC) is an infusion catheter system designed to introduce physician-specified medicaments into

More information

FLEXIC ATH LTD. Peripherally Inserted. Instructions n For Use.

FLEXIC ATH LTD. Peripherally Inserted. Instructions n For Use. FLEXIC ATH LTD * M/29M Peripherally Inserted Catheter Instructions n For Use This leaflet contains instructions for both stan- dard needle-introducer er and protection con- tained M/29 models, i.e., with

More information

Step by step description - Use of Bonopty Bone Biopsy System, 14 gauge

Step by step description - Use of Bonopty Bone Biopsy System, 14 gauge Step by step description - Use of Bonopty Bone Biopsy System, 14 gauge Before use, please read the Instructions For Use which accompany the product for indications, contraindications, warnings and precautions.

More information

Instructions for Use Neulasta (nu-las-tah) (pegfilgrastim) Injection, for subcutaneous use Single-Dose Prefilled Syringe. Plunger rod Used plunger rod

Instructions for Use Neulasta (nu-las-tah) (pegfilgrastim) Injection, for subcutaneous use Single-Dose Prefilled Syringe. Plunger rod Used plunger rod Instructions for Use Neulasta (nu-las-tah) (pegfilgrastim) Injection, for subcutaneous use Single-Dose Prefilled Syringe Guide to parts Before use After use Plunger rod Used plunger rod Finger grip Label

More information

Lotus transducer Instructions for use

Lotus transducer Instructions for use Lotus transducer Instructions for use Instructions for use transducer Before using the product, please read the following information thoroughly Important This document provides instructions for using

More information

Transjugular liver access and biopsy

Transjugular liver access and biopsy Transjugular liver access and biopsy An illustrated guide Illustrations by Lisa Clark LABS LIVER ACCESS AND BIOPSY SET MEDICAL Support your procedures by using products that are specifically designed for

More information

EX-PRESS Glaucoma Filtration Device Surgical Procedure

EX-PRESS Glaucoma Filtration Device Surgical Procedure EX-PRESS Glaucoma Filtration Device Surgical Procedure Surgical Recommendations EX-PRESS Glaucoma Filtration Device preloaded device (plus 1 back-up) Sterile caliper Lid speculum Corneal forceps 0.12 forceps

More information

Precautionary Statement ( )

Precautionary Statement ( ) Precautionary Statement (21282008) Biomet Sports Medicine, Inc. 21282008 4861 E. Airport Dr. Rev. A Ontario, CA 91761 Date: 06/07 Sleeve and Button Soft Tissue Devices Utilizing ZipLoop Technology ATTENTION

More information

Step by step description - Use of Bonopty Bone Biopsy System, 12 gauge

Step by step description - Use of Bonopty Bone Biopsy System, 12 gauge Step by step description - Use of Bonopty Bone Biopsy System, 12 gauge Before use, please read the Instructions For Use which accompany the product for indications, contraindications, warnings and precautions.

More information

Doc no: IFU/CPL Issue date: Rev no: 00 Rev date: 1

Doc no: IFU/CPL Issue date: Rev no: 00 Rev date: 1 FUTURA SURGICARE PVT LTD INSTRUCTION FOR USE Brand name: PROGUT Material: Catgut Plain. Absorbable surgical suture U.S.P Description: Progut surgical catgut suture is a sterile absorbable suture composed

More information

Tibial Fixation. with TunneLoc Device. Surgical Technique by Mark J. Albritton, M.D. and Sherwin Ho, M.D.

Tibial Fixation. with TunneLoc Device. Surgical Technique by Mark J. Albritton, M.D. and Sherwin Ho, M.D. Tibial Fixation with TunneLoc Device Surgical Technique by Mark J. Albritton, M.D. and Sherwin Ho, M.D. Table of Contents Surgical Technique... 4 Ordering Information... 11 Indications For Use... 12 Contraindications...

More information

DISTAL RADIUS. Instructions for Use

DISTAL RADIUS. Instructions for Use DISTAL RADIUS Instructions for Use CAUTION: FEDERAL LAW RESTRICTS THESE DEVICES TO SALE BY OR ON THE ORDER OF A PHYSICIAN. Table of Contents 1. INTENDED USE... 3 2. DEVICE DESCRIPTION... 3 3. METHOD OF

More information

Comprehensive Product Offerings for Your Rotator Cuff Repair

Comprehensive Product Offerings for Your Rotator Cuff Repair Pioneering Rotator Cuff Repair Solutions Comprehensive Product Offerings for Your Rotator Cuff Repair Cu HEALICOIL REGENESORB Suture Anchor ULTRATAPE Suture HEALICOIL PK Suture Anchor SHO15_04100_V2_RC_Solutions_BRO_8.3x11_F.indd

More information

Instructions for Use Reprocessed Ethicon ENDOPATH XCEL TM Bladeless Trocar with OPTIVIEW Technology

Instructions for Use Reprocessed Ethicon ENDOPATH XCEL TM Bladeless Trocar with OPTIVIEW Technology Reprocessed by Instructions for Use Reprocessed Ethicon ENDOPATH XCEL TM Bladeless Trocar with OPTIVIEW Technology Reprocessed Device for Single Use Caution: Federal (U.S.A.) law restricts this device

More information

AERO DV Tracheobronchial Direct Visualization Stent System

AERO DV Tracheobronchial Direct Visualization Stent System AERO DV Tracheobronchial Direct Visualization Stent System Review Instructions For Use Before Using This System. Single Use Only Non-sterile MR Conditional CONTENTS Instructions for Use...............................

More information

ACL reconstruction with the ACUFEX Director Drill Guide and. ENDOBUTTON CL Fixation System. *smith&nephew. Knee Series Technique Guide ENDOBUTTON CL

ACL reconstruction with the ACUFEX Director Drill Guide and. ENDOBUTTON CL Fixation System. *smith&nephew. Knee Series Technique Guide ENDOBUTTON CL Knee Series Technique Guide *smith&nephew ENDOBUTTON CL Fixation System ACL reconstruction with the ACUFEX Director Drill Guide and ENDOBUTTON CL Fixation System Thomas D. Rosenberg, MD ACL Reconstruction

More information

ACL Primary Repair Surgical Technique

ACL Primary Repair Surgical Technique ACL Primary Repair Surgical Technique ACL Primary Repair ACL Primary Repair BioComposite SwiveLock and Labral Scorpion Suture Passing Technology There has been a recent resurgence of interest in the possibility

More information

Instructions for Use Reprocessed ENDOPATH XCEL Bladeless Endoscopic Trocars and Cannulas. Reprocessed Device for Single Use.

Instructions for Use Reprocessed ENDOPATH XCEL Bladeless Endoscopic Trocars and Cannulas. Reprocessed Device for Single Use. Reprocessed by Instructions for Use Reprocessed ENDOPATH XCEL Bladeless Endoscopic Trocars and Cannulas Reprocessed Device for Single Use Caution: Federal (U.S.A.) law restricts this device to sale by

More information

PCL GraftLink Surgical Technique

PCL GraftLink Surgical Technique PCL GraftLink Surgical Technique PCL GraftLink GraftLink Minimally Invasive PCL Reconstruction The GraftLink technique provides the ultimate in anatomic, minimally invasive, and reproducible PCL reconstruction

More information

Quality. Elegance. Innovation.

Quality. Elegance. Innovation. Quality. Elegance. Innovation. Triumph Orthodontic Instruments Quality and engineering come together for superior performance The Triumph Orthodontic Instrument line provides the orthodontic professional

More information

Document No. BMB/IFU/40 Rev No. & Date 00 & 15/11/2017 Issue No & Date 01 & 15/11/2017

Document No. BMB/IFU/40 Rev No. & Date 00 & 15/11/2017 Issue No & Date 01 & 15/11/2017 Central Venous Catheter Device Description Multi-lumen catheters incorporate separate, non-communicating vascular access lumens within a single catheter body. Minipunctur Access Sets And Trays: Used for

More information

Rotator Cuff Repair Utilizing the ALLthread Suture Anchor. by Scott Kuiper, M.D.

Rotator Cuff Repair Utilizing the ALLthread Suture Anchor. by Scott Kuiper, M.D. Rotator Cuff Repair Utilizing the ALLthread Suture Anchor by Scott Kuiper, M.D. The Material Difference Biomet Sports Medicine recognizes the benefit of material options. Many times surgeons require different

More information

ARTHROTUNNELER TUNNELPRO SYSTEM

ARTHROTUNNELER TUNNELPRO SYSTEM TORNIER ARTHROTUNNELER TUNNELPRO SYSTEM Transosseous Rotator Cuff Repair SURGICAL TECHNIQUE ARTHROTUNNELER TUNNELPRO SYSTEM ARTHROTUNNELER Surgical Technique Step 1. Drill medial tunnel(s) to a positive

More information

Three Arthroscopic Techniques for Repairing the Rotator Cuff using ULTRATAPE Suture

Three Arthroscopic Techniques for Repairing the Rotator Cuff using ULTRATAPE Suture *smith&nephew SHOULDER TECHNIQUE GUIDE Three Arthroscopic Techniques for Repairing the Rotator Cuff using ULTRATAPE Suture Scott W. Trenhaile, MD KNEE HIP SHOULDER EXTREMITIES As Described by: Scott W.

More information

RIGIDfix. Soft Tissue. Surgical Technique for Mitek RIGIDfix ACL Reconstruction PRODUCTS. Daniel J. McKernan, M.D. TISSUE SOFT.

RIGIDfix. Soft Tissue. Surgical Technique for Mitek RIGIDfix ACL Reconstruction PRODUCTS. Daniel J. McKernan, M.D. TISSUE SOFT. RIGIDfix A C L C R O S S P I N S Y S T E M Daniel J. McKernan, M.D. Toledo, Ohio SOFT TISSUE Surgical Technique for Mitek RIGIDfix ACL Reconstruction Soft Tissue PRODUCTS SURGICAL TECHNIQUE RIGIDfix A

More information

The SplitWire Percutaneous Transluminal Angioplasty Scoring Device. Instructions for Use

The SplitWire Percutaneous Transluminal Angioplasty Scoring Device. Instructions for Use The SplitWire Percutaneous Transluminal Angioplasty Scoring Device Instructions for Use Contents Contains one (1) SplitWire device. Sterile. Sterilized with ethylene oxide gas. Radiopaque. For single use

More information

Double Bundle PCL Reconstruction. Surgical Technique

Double Bundle PCL Reconstruction. Surgical Technique Double Bundle PCL Reconstruction Surgical Technique Double Bundle PCL Reconstruction With recent interest in double tunnel endoscopic PCL reconstruction, Arthrex has created a series of Femoral PCL Drill

More information

Corex HOSPITAL OVERVIEW AND TECHNICAL ASSESSMENT TECHNOLOGY OVERVIEW NEW TECHNOLOGY REFERENCE GUIDE. Minimally Invasive Bone Harvester

Corex HOSPITAL OVERVIEW AND TECHNICAL ASSESSMENT TECHNOLOGY OVERVIEW NEW TECHNOLOGY REFERENCE GUIDE. Minimally Invasive Bone Harvester NEW TECHNOLOGY REFERENCE GUIDE Corex Minimally Invasive Bone Harvester HOSPITAL OVERVIEW AND TECHNICAL ASSESSMENT The Corex Bone Harvester is a supplied sterile, single patient use, manually operated trephine

More information

Doc no: IFU/CC Issue date: Rev no: 04 Rev date:

Doc no: IFU/CC Issue date: Rev no: 04 Rev date: FUTURA SURGICARE PVT LTD INSTRUCTION FOR USE Brand name: PROGUT Material: Catgut Chromic Absorbable surgical suture U.S.P Description: Progut surgical catgut suture is a sterile absorbable suture composed

More information

Quick Reference Guide

Quick Reference Guide Quick Reference Guide Indications for Use The AFX Endovascular AAA System is indicated for endovascular treatment in patients with AAA. The devices are indicated for patients with suitable aneurysm morphology

More information

Orthopaedic Cable System

Orthopaedic Cable System Cerclage Solutions for General Surgery Orthopaedic Cable System Surgical Technique Table of Contents Introduction Orthopaedic Cable System 2 Indications 4 Contraindications 4 Surgical Technique Cerclage

More information

Stratis INSTRUCTIONS FOR USE. Needle-free Injection System. 0.5mL volume (+/-5%)

Stratis INSTRUCTIONS FOR USE. Needle-free Injection System. 0.5mL volume (+/-5%) Stratis Needle-free Injection System INSTRUCTIONS FOR USE 0.5mL volume (+/-5%) Stratis English Symbols Glossary (Note: All symbols are derived from ISO 15223-1, Medical Devices - Symbols to be used with

More information

AXS Catalyst Distal Access Catheter

AXS Catalyst Distal Access Catheter AXS Catalyst Distal Access Catheter Directions for Use 2 AXS Catalyst Distal Access Catheter ONLY Caution: Federal Law (USA) restricts this device to sale by or on the order of a physician. warning Contents

More information

Doxpal. Self-retaining Retractor

Doxpal. Self-retaining Retractor Doxpal Self-retaining Retractor Doxpal Easy to use and reposition Doxpal retractors are easy to use and easy to reposition due to the elastic properties of the plastic. There are no locking devices to

More information

Initial placement 24FR Pull PEG kit REORDER NO:

Initial placement 24FR Pull PEG kit REORDER NO: Initial placement 24FR Pull PEG kit REORDER NO: 00710805 INSTRUCTIONS FOR USE 1 of 5 These products have been manufactured not to include latex. Intended Use: The Initial placement 24FR Pull PEG kit is

More information

ACL Reconstruction Cross-Pin Technique

ACL Reconstruction Cross-Pin Technique ACL Reconstruction Cross-Pin Technique Surgical Technique Lonnie E. Paulos, MD Salt Lake City, Utah 325 Corporate Drive Mahwah, NJ 07430 t: 201 831 5000 www.stryker.com A surgeon should always rely on

More information

CATHETER ACCESS KIT. For use with Prometra Programmable Infusion Systems

CATHETER ACCESS KIT. For use with Prometra Programmable Infusion Systems CATHETER ACCESS KIT Caution: Federal (USA) Law restricts this device to sale by or on the order of a physician. Table of Contents Contents... 3 Description... 3 Indications... 3 Contraindications... 3

More information

JuggerLoc Bone-to-Bone System for Ankle Syndesmosis Fixation. Surgical Technique

JuggerLoc Bone-to-Bone System for Ankle Syndesmosis Fixation. Surgical Technique JuggerLoc Bone-to-Bone System for Ankle Syndesmosis Fixation Surgical Technique Table of Contents Position and Preparation... 2 Incision... 2 Fracture Reduction... 2 Drill Fibula and Tibia... 3 JuggerLoc

More information

Hip arthroscopy using the Smith & Nephew Hip Access System

Hip arthroscopy using the Smith & Nephew Hip Access System Hip Series Technique Guide *smith&nephew HIP ACCESS SYSTEM Hip Arthroscopy System Hip arthroscopy using the Smith & Nephew Hip Access System Victor M. Ilizaliturri, Jr., M.D. Hip arthroscopy using the

More information

EndoRelease ENDOSCOPIC CUBITAL TUNNEL RELEASE SYSTEM

EndoRelease ENDOSCOPIC CUBITAL TUNNEL RELEASE SYSTEM EndoRelease ENDOSCOPIC CUBITAL TUNNEL RELEASE SYSTEM SURGICAL TECHNIQUE Up p e r Ex t r e m i t y So l u t i o n s ENDOSCOPIC CUBITAL TUNNEL RELEASE SYSTEM Description: The EndoRelease Endoscopic Cubital

More information

Step by Step Description Use of Bonopty Coaxial Bone Biopsy System

Step by Step Description Use of Bonopty Coaxial Bone Biopsy System Step by Step Description Use of Bonopty Coaxial Bone Biopsy System Before use, please read the Instructions For Use which accompany the product for indications, contraindications, warnings and precautions.

More information

Flexible Fragment Fixation. Surgical Technique

Flexible Fragment Fixation. Surgical Technique Flexible Fragment Fixation Surgical Technique 2 F 3 Flexible Fragment Fixation The F 3 Fragment Plating System offers low profile, yet strong fixation in a locked plating construct that can be contoured

More information

Mini External Fixator

Mini External Fixator Stabilize the Phalanges and Metacarpals Mini External Fixator Surgical Technique Table of Contents Introduction Mini External Fixator 2 Indications 4 Surgical Technique Technique Overview 5 Product Information

More information

Initial placement 20FR Guidewire PEG kit REORDER NO:

Initial placement 20FR Guidewire PEG kit REORDER NO: Initial placement 20FR Guidewire PEG kit REORDER NO: 00710802 INSTRUCTIONS FOR USE 1 of 5 These products have been manufactured not to include latex. Intended Use: The Initial placement 20FR Guidewire

More information

TWISTR TM Retrograde Reamer & Cruciate+ Instruments Surgical Technique

TWISTR TM Retrograde Reamer & Cruciate+ Instruments Surgical Technique TWISTR TM Retrograde Reamer & Cruciate+ Instruments Surgical Technique Guide Carriage Suture Passing Pin Step 1: Set the TWISTR TM Retrograde Reamer to drill the desired socket / tunnel diameter by twisting

More information

Instructions for Use Reprocessed Arthroscopic Shavers

Instructions for Use Reprocessed Arthroscopic Shavers Reprocessed by Instructions for Use Reprocessed Arthroscopic Shavers Reprocessed Device for Single Use Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician. STERILE

More information

Integra SURGICAL TECHNIQUE. MemoFix Super Elastic Nitinol Staple System. Super Elastic Nitinol Staple System

Integra SURGICAL TECHNIQUE. MemoFix Super Elastic Nitinol Staple System. Super Elastic Nitinol Staple System Integra MemoFix Super Elastic Nitinol Staple System SURGICAL TECHNIQUE Super Elastic Nitinol Staple System Table of Contents Design Rationale...2 System Features...2 Indications...2 Contraindications...2

More information

Aspira* Peritoneal Drainage Catheter

Aspira* Peritoneal Drainage Catheter Aspira* Peritoneal Drainage Catheter Instructions For Use Access Systems Product Description: The Aspira* Peritoneal Drainage Catheter is a tunneled, long-term catheter used to drain accumulated fluid

More information

OptiFix Absorbable Fixation System

OptiFix Absorbable Fixation System OptiFix Absorbable Fixation System Absorbable Fixation Redefined Advancing the Fixation Experience. SOFT TISSUE REPAIR Right Procedure. Right Product. Right Outcome. Hernia Repair Fixation Challenges and

More information

Endorectal Balloon (ERB) Endorectal Balloon (ERB) Instructions for Use

Endorectal Balloon (ERB) Endorectal Balloon (ERB) Instructions for Use Endorectal Balloon (ERB) Instructions for Use GRF-0004-00 Rev. 08 Page 1 of 9 Contents Instructions for Use... 3 Indications for Use... 3 Contraindications... 3 Storage... 4 Warnings... 4 Accessories Provided...

More information

Positioning System. Laparoscopic ventral hernia repair KEY BENEFITS SOFT TISSUE REPAIR

Positioning System. Laparoscopic ventral hernia repair KEY BENEFITS SOFT TISSUE REPAIR Echo PS Positioning System with Ventralight ST Mesh or Composix L/P Mesh Laparoscopic ventral hernia repair Echo PS Positioning System with Ventralight ST Mesh Echo PS Positioning System with Composix

More information