ZIVAK TECHNOLOGIES. Multitasker-LC Walk Away UHPLC Analyzer For LC-MS/MS
|
|
- Maximilian Strickland
- 6 years ago
- Views:
Transcription
1 ZIVAK TECHNOLOGIES Multitasker-LC Walk Away UHPLC Analyzer For LC-MS/MS
2 Clinical Diagnostic Market Roche, Siemens,Midray Abbott, Beckman Currrent Clinical Diagnostic Market Immunoassay, ELISA, RIA,FIA Sciex, Agilent, Thermo Shimadzu, Waters.. Clinical Diagnosis with LC-MS/MS and HPLC Gold Standart Methods WHY?
3 2. False positive samples, when the results of the reference assay (LC-MS/MS-total-D) were less than 40 nmol/l but one or more of the immunoassays gave greater than or equal to 40 nmol/l. State-of-the-Art Vitamin D Assays: A Comparison of Automated Immunoassays with Liquid Chromatography Tandem Mass Spectrometry Methods Christopher-John L. Farrell,1,2 Steven Martin,1 Brett McWhinney,3 Isabella Straub,4 Paul Williams,5 and Markus Herrmann1,4* Clinical Chemistry 58: (2012)
4 NIST USA Traceability Report for Different Technics for Vit D2-D3 (Zivak 243A and 243B)
5 Limitations of HPLC and LC-MS/MS For Routine Clinical Use Roche, Siemens,Midray Abbott, Beckman Currrent Clinical Diagnostic Market Immunoassay, ELISA, RIA,FIA %95-97 FUTURE Ready to Use Analysis Kits Automation and Barcode Reading Walk-away HPLC and LC-MS/MS Analysers Sciex, Agilent, Thermo Shimadzu, Waters.. Clinical Diagnosis with LC-MS/MS and HPLC Gold Standart Methods %3-5
6 LC-MS/MS vs Immunoassay Advantages Disadvantages MS/MS methods High Specificity High Sensitivity Lower Kit Costs Multiplexing Measurements High Throughput Non-Automated Qualified staff required The need of rigorous kit validation Automated Barcode Reading Direct injection from Vacu tube Higher maintenance cost (20 K USD / year) Higher owner capital cost (200 K USD / device) Immunoassay Automated No need for qualified staff Validated kits Affordable prices Better traceability (barcode readers, Online LIS connection) Low Specificity Low Sensitivity Higher Kit Costs High Potential for interference
7 LC-MS/MS vs Immunoassay Advantages Disadvantages Zivak Multitasker Automated LC-MS/MS System High Specificity High Sensitivity Lower Kit Costs Multiplexing Measurements High Throughput Non-Automated Qualified staff required The need of rigorous kit validation Automated Barcode Reading Direct injection from Vacutube Online LIS connection Higher maintenance cost (20 K USD / year) Higher owner capital cost (200 K USD / device) Immunoassay Automated No need for qualified staff Validated kits Affordable prices Better traceability (barcode readers, Online LIS connection) Low Specificity Low Sensitivity Higher Kit Costs High Potential for interference
8 Turn Your LC-MS/MS Instrument into Walk Away Clinical Analyzer Roche, Siemens, Midray Abbott, Beckman Currrent Clinical Diagnostic Market Immunoassay, ELISA, RIA,FIA Sciex, Agilent, Thermo Shimadzu, Waters.. Clinical Diagnosis with LC-MS/MS and HPLC Gold Standart Methods
9 Zivak Multitasker-LC OUR VISION Each LC-MS/MS will need an automated sample prep LC Zivak Multitasker Full Automated Sample Preparation and Injection System
10 Multitasker - LC with TandemGold MS Turkey
11 Multitasker - LC with Shimadzu 8040 MS India
12 Multitasker LC with Sciex 4500 MS Italy
13 Multitasker - LC with Thermo TSQ MS South Korea
14 HB-100 New Design 2017 The New HBA1c Analyser 1,5 min analysis time for HbA1c and HbF 6,0 min analysis time for A1c, F, A0, A2, S, C, D, E Variants Real walk-away system with unique modules
15 Zivak NEW VD-200 D2-D3 Analyser UHPLC System World s only Walk-Away 25-OH Vitamin D2-D3 UHPLC-UV System April-2016
16 HPLC and LC/MS/MS Kits 16
17 Kit Test Times (sample prep. + run time) Psychoactive Drugs Urine LC-MS/MS Analysis Kit Amino Acid Biological Fluids LC-MS/MS Analysis Kit PKU Serum LC-MS/MS Analysis Kit PKU Dried Blood Spots LC-MS/MS Analysis Kit Organic Acid Urine LC-MS/MS Analysis Kit Neonatal Screening Dried Blood Spots LC-MS/MS Analysis Kit Immunosuppressant Whole Blood LC-MS/MS Analysis Kit VMA HVA 5-HIAA Urine LC-MS/MS Analysis Kit Catecholamines Urine LC-MS/MS Analysis Kit Metanephrine Urine LC-MS/MS Analysis Kit Neurotransmitters in Urine LC-MS/MS Analysis Kit 25-Hydroxyvitamin D2-D3 Serum LC-MS/MS APCIAnalysis Kit Total Homocysteine Serum LC-MS/-MS Analysis Kit Hemoglobin A1c Whole Blood HPLC Analysis Kit Hemoglobin Variant Whole Blood HPLC Analysis Kit PKU Serum HPLC Analysis Kit PKU Dried Blood Spots HPLC Analysis Kit 25-Hydroxyvitamin D2-D3 Serum HPLC Analysis Kit Vitamin A-E Serum HPLC Analysis Kit 25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit 7 min 20 min 2 min 2 min 20 min 1.5 min 2 min 15 min 16 min 13 min 13 min 2 min 2.5 min 1.5 min 6.5 min 2 min 2 min 6 min 8 min 3 min
18 Matrix /IS Labeled Standarts,Controls and Calibrators. 18
19 Clinical HPLC Analysis Kits HbA1C in Whole Blood Hb Variant and ß-Thalassemia 25-OH Vitamin D2/D3 in Serum Phe, Tyr and Trp in Serum & Plasma and DBS
20
Distribuido en España por: INGENIERIA ANALITICA S.L Tel: Fax:
Distribuido en España por: INGENIERIA ANALITICA S.L Tel: +34 902.45.6677 Fax: +34 902.46.6677 www.ingenieria-analitica.com inf@ingenieria-analitica.com FUTURANAYSIS About Zivak UNIQUE SOLUTION FROM ONE
More informationSCIEX Vitamin D 200M Assay for the Topaz System
The First FDA-Cleared LC-MS/MS Assay for Vitamin D SCIEX Vitamin D 200M Assay for the Topaz System The first FDA-cleared LC-MS/MS assay for Vitamin D Vitamin D is an important building block for human
More informationA High-throughput Mass Spectrometry Multiplexed Assay to Measure Insulin and C- peptide
A High-throughput Mass Spectrometry Multiplexed Assay to Measure Insulin and C- peptide Steven W. Taylor 1, Zhaohui Chen 1,2, Richard E. Reitz 1, Michael J. McPhaul 1, Nigel J. Clarke 1 1 Quest Diagnostics
More information25-Hydroxyvitamin D assay performance. Graham Carter Imperial College
25-Hydroxyvitamin D assay performance Graham Carter Imperial College www.deqas.org Outline of Talk 1. DEQAS: Organization and Objectives 2. Mean Assay Bias and Precision 3. Bias of individual samples
More informationNutrition: obtaining reliable biomarker data to study the health status of populations
Nutrition: obtaining reliable biomarker data to study the health status of populations Christine M. Pfeiffer, Ph.D. Chief, Nutritional Biomarkers Branch, DLS AAAS 2011 Annual Meeting Science Without Borders
More informationPKU (Phenylketonuria) Serum LC-MS/MS Analysis Kit User Manual
Page 1 / 24 PKU (Phenylketonuria) Serum LC-MS/MS Analysis Kit User Manual ZV-3003-0200-10 200 2-8 C Page 2 / 24 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. TEST PRINCIPLE...
More informationAll stocks and calibration levels were prepared in water: methanol (50:50) v/v to cover range of all steroid concentrations (refer Table 1).
Application LCMS-8040 Simultaneous determination of 11 steroids and Vitamin D2/D3 in human serum using LC/MS/MS - Introduction Quantification of endogenous hormonal steroids and their precursors is essential
More informationDisclosure: No conflict of interests to disclose
Mei Chung, PhD MPH Assistant Professor Nutrition/Infection Unit, Department of Public Health and Community Medicine, School of Medicine, Tufts University 0 1 Disclosure: No conflict of interests to disclose
More informationAn Introduction to the Use of itraq Reagents for Amino Acid Analysis
An Introduction to the Use of itraq Reagents for Amino Acid Analysis Lisa Sapp Clinical Research and Forensic Toxicology Product Manager Mass Spectrometry Systems Amino Acid Analysis Using itraq Reagents
More informationCortisol Assays. The Good, The Bad and The Indifferent. David Ducroq. Cardiff and Vale ulhb WEQAS. Unit 6, Parc Tŷ Glas. Llanishen.
Cortisol Assays The Good, The Bad and The Indifferent David Ducroq Cardiff and Vale ulhb WEQAS Unit 6, Parc Tŷ Glas Llanishen Cardiff www.weqas.com Summary Brief overview of current methods and challenges
More informationMass Spectrometry Made Simple for Clinical Diagnostic Labs
Mass Spectrometry Made Simple for Clinical Diagnostic Labs The SCIEX Topaz System with FDA-Cleared Topaz Vitamin D 200M Assay Kit Mass Spectrometry Made Simple SCIEX Topaz System for Clinical Diagnostics
More informationAbstract. Introduction
A Fast Dilute-And-Shoot Method for Simultaneous 5-Hydroxyindoleacetic Acid (5-HIAA), Vanillylmandelic Acid (VMA), and Homovanillic Acid (HVA) LC-MS/MS Analysis in Human Urine By Shun-Hsin Liang and Sue
More informationCatecholamines and neurotransmitter. Comprehensive tools for routine and research
Catecholamines and neurotransmitter diagnostics Comprehensive tools for routine and research Neurotransmitters in human and animals Catecholamines and neurotransmitters play essential roles in both humans
More informationPKU (Phenylketonuria) Serum HPLC Analysis Kit User Manual
Page 1 / 20 PKU (Phenylketonuria) Serum HPLC Analysis Kit User Manual ZV-4003-0200-10 200 2-8 C Page 2 / 20 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. TEST PRINCIPLE... 3
More informationDayana Argoti, Kerry Hassell, Sarah J. Fair, and Joseph Herman Thermo Fisher Scientific, Franklin, MA, USA
The Utilization of Novel Platform in a LC-MS/MS Workflow for the Analysis of Vitamin D, Testosterone, Immunosuppressants, Chemotherapeutics and Cortisol Dayana Argoti, Kerry Hassell, Sarah J. Fair, and
More informationQuantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation
Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation Valérie Thibert, Bénédicte Duretz Thermo Fisher Scientific, Courtaboeuf,
More informationClinical Mass Spectrometry Case Studies: How we can Read Between the Lines
Clinical Mass Spectrometry Case Studies: How we can Read Between the Lines Alec Saitman Ph.D., DABCC (CC, TC) Director Special Chemistry and Toxicology Providence Regional Laboratories Disclosures None
More informationLC-MS/MS Challenges in a High-Throughput Clinical Chemistry Laboratory Michael Wright
LC-MS/MS Challenges in a High-Throughput Clinical Chemistry Laboratory Michael Wright SEALS Prince of Wales Hospital Randwick, NSW Clinical Chemistry From an Analytical Chemist Perspective How do you test
More informationLC-MS/MS Method for the Determination of Tenofovir from Plasma
LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract
More informationEvaluation of the LIAISON 25 OH Vitamin D TOTAL Assay on the new LIAISON XL analyser
Evaluation of the LIAISON 25 OH Vitamin D TOTAL Assay on the new LIAISON XL analyser Prof. Etienne Cavalier Department of Clinical Chemistry University of Liège, CHU Sart-Tilman Liège, Belgium etienne.cavalier@chu.ulg.ac.be
More informationHigh-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine
High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring and in Urine Xiaolei Xie, Joe DiBussolo, Marta Kozak; Thermo Fisher Scientific, San Jose, CA Application Note 627 Key Words, norbuprenorphine,
More informationFully automated sensitive determination of immunosuppressant drugs in whole blood, using high quality internal standardization
PO-CON1773E Fully automated sensitive determination of immunosuppressant drugs in whole blood, using high quality internal standardization ASMS 2017 ThP-086 Marc FERNANDEZ 1, Aurore JAFFUEL 1, Fanny DAYOT
More informationProcedure for Toxicology Analysis Version 7 Toxicology Unit Effective Date: 03/14/2014 Issued by Drug Chemistry Forensic Scientist Manager
Toxicology Analysis 1.0 Purpose - This procedure specifies the required elements for analyzing toxicology submissions and reporting drug testing results. 2.0 Scope This procedure applies to all submissions
More informationDIRECT ENZYMATIC HbA1c ASSAY
DIRECT ENZYMATIC HbA1c ASSAY ACCURATE AND SIMPLE DIAZYME INNOVATIONS IN CLINICAL DIAGNOSTICS About Diazyme Diazyme Laboratories is a Division of General Atomics located in Poway, California. Diazyme uses
More information25 OH Vitamin D Rapid test
INSTRUCTION FOR USE REF:GDB 7120-25T 25 OH Vitamin D Rapid test Rapid Whole Blood Vitamin D Test A Rapid Sandwich Immunochromatographic Test for the Quantitative Detection of total 25-OH Vitamin D in human
More informationReal-time PK Measurement of the Chemotherapeutic Drug Melphalan in Whole Blood by a Novel PaperSpray Mass Spectrometry
Palm Springs, California February 21-25 Real-time PK Measurement of the Chemotherapeutic Drug Melphalan in Whole Blood by a Novel PaperSpray Mass Spectrometry Junfang Zhao, Chandra Sharat, Parinda A. Mehta,
More information25 OH Vitamin D Rapid Test
INSTRUCTION FOR USE REF:GDB 7120-25T 25 OH Vitamin D Rapid Test A Rapid Sandwich Immunochromatographic Test for Quantitative Detection of total 25-OH Vitamin D in human finger-prick blood For In Vitro
More informationThe Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis
The Investigation of Factors Contributing to Immunosuppressant Drugs Variability in LC-MS/MS Analysis Joseph Herman, Dayana Argoti, and Sarah Fair Thermo Fisher Scientific, Franklin, MA, USA Overview Purpose:
More informationNeonatal Screening using Shimadzu LCMS-8040
PO-CON1355E Neonatal Screening using Shimadzu LCMS-8040 HPLC 2013 BIOM-31 Stefano Zaza 1 ; G. La Marca 2 ; S.Malvagia 2 1 Shimadzu Italy, Milano, Italy 2 Mass Spectrometry and Pharmacology Laboratory,
More informationUse of a Tandem Mass Spectrometry Research Method for the Analysis of Amino Acids and Acylcarnitines in Dried Blood Spots
Use of a Tandem Mass Spectrometry Research Method for the Analysis of Amino Acids and Acylcarnitines in Dried Blood Spots Xiaolei Xie and Marta Kozak Thermo Fisher Scientific, San Jose, CA, USA Application
More informationAPCCMS2010 Hong Kong Jan th Applied Biosystems LCMSMS Industry Workshop. Dr Matthew Grigg Asia Pacific Marketing and Support Manager
APCCMS2010 Hong Kong Jan 14-16 th Applied Biosystems LCMSMS Industry Workshop Dr Matthew Grigg Asia Pacific Marketing and Support Manager 2 2010 Applied Biosystems LLC and MDS Inc. Joint Owners AB SCIEX
More informationMethodology Report Total 25-Hydroxyvitamin D Determination by an Entry Level Triple Quadrupole Instrument: Comparison between Two Commercial Kits
BioMed Volume 213, Article ID 27426, 5 pages http://dx.doi.org/1.1155/213/27426 Methodology Report Total 25-Hydroxyvitamin D Determination by an Entry Level Triple Quadrupole Instrument: Comparison between
More informationMaria João Mendes Mendonça Barreira Department of Health Promotion and Chronic Deseases, INSA
Quantification of four immunosuppressant drugs by Liquid Chomatography-Tandem Mass Spectrometry using Direct Injection. Maria João Mendes Mendonça Barreira Department of Health Promotion and Chronic Deseases,
More informationVitamin D A game changer for Clinical Laboratories
Vitamin D A game changer for Clinical Laboratories Michael Wright Clinical Chemistry and Endocrinology Department, SEALS Prince of Wales Hospital Sydney, Australia What is 25OH Vitamin D? 25OH Vitamin
More informationCarnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual
Page 1 / 14 Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual ZV-3051-0200-15 200 Page 2 / 14 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. TEST
More informationSPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine
SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA
More informationDiscrepancy between Vitamin D Total Immunoassays due to Various Cross-reactivities
J Bone Metab ;22:7-112 http://dx.doi.org/.105/jbm..22.3.7 pissn 2287-6375 eissn 2287-7029 Original Article Discrepancy between Vitamin D Total Immunoassays due to Various Cross-reactivities Jun Hyung Lee,
More informationBio-Rad Laboratories. Hemoglobin Testing. VARIANT II Hemoglobin Testing System For HbA 1c
Bio-Rad Laboratories Hemoglobin Testing VARIANT II Hemoglobin Testing System For HbA 1c Bio-Rad CDM System CDM 5.1 VII Instrument Patient Report V2_A1c_NU Patient Data Sample ID: AD Patient ID: Name: Physician:
More informationDrug Testing Policy. Reimbursement Policy CMS Approved By. Policy Number. Annual Approval Date. Reimbursement Policy Oversight Committee
Reimbursement Policy CMS 1500 Drug Testing Policy Policy Number 2017R6005A Annual Approval Date 05/10/2017 Approved By Reimbursement Policy Oversight Committee IMPORTANT NOTE ABOUT THIS REIMBURSEMENT POLICY
More informationLab Guide 2019 Metabolic Section Lab Guide
Lab Guide 2019 Metabolic Section Lab Guide Quantitative Amino acids Plasma Plasma. Container/Tube: Preferred EDTA, Place immediately in ice. Acceptable: lithium heparin, sodium heparin. Patient preparation:
More informationEvidence Based HbA1c Accuracy. Sabrina Koetsier Medical Scientist RCPAQAP Chemical Pathology
Evidence Based HbA1c Accuracy Sabrina Koetsier Medical Scientist RCPAQAP Chemical Pathology Fresh lycohaemoglobin This program is designed to assist laboratories to assess the accuracy of their hihba1c
More informationImproving the Accuracy of Hemoglobin A 1c. : Your Help Is Needed
Improving the Accuracy of Hemoglobin A 1c : Your Help Is Needed Kristina Jackson Behan, PhD, MT(ASCP) (Clinical Laboratory Sciences Program, University of West Florida, Pensacola, FL) DOI: 10.1309/RTVTWPYPTPA5YAGU
More information25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual
Page 1 / 12 25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual ZV-4027-0500-10 500 2-8 C Page 2 / 12 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. IVD SYMBOLS...
More informationHPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. First HPLC Analyzer to Aid in Diagnosis of Diabetes
HPLC ANALYZER Gold Standard Accuracy by Ion-Exchange HbA1c First HPLC Analyzer to Aid in Diagnosis of Diabetes TOSOH BIOSCIENCE www.tosohbioscience.us HPLC ANALYZER HbA1c analysis in 1.6 minutes Direct
More informationDetection of Cannabinoids in Oral Fluid with the Agilent 7010 GC-MS/MS System
Application Note Forensics, Workplace Drug Testing Detection of Cannabinoids in Oral Fluid with the Agilent 7010 GC-MS/MS System Authors Fred Feyerherm and Anthony Macherone Agilent Technologies, Inc.
More informationImproving Benzodiazepine Immunoassay Sensitivity by Rapid Glucuronide Hydrolysis Technology
Improving Benzodiazepine Immunoassay Sensitivity by Rapid Glucuronide Hydrolysis Technology Pongkwan (Nikki) Sitasuwan, Margarita Marinova, and L. Andrew Lee Integrated Micro-Chromatography Systems, LLC
More informationIdentification and Quantification of Psychedelic Phenethylamine 2C Series using SPE and LC-MS/MS
Identification and Quantification of Psychedelic Phenethylamine 2C Series using SPE and LC-MS/MS UCT Part Numbers: CSXCE106-Clean Screen XCEL I 130mg/6mL SLDA100ID21-3UM - Selectra DA HPLC column, 100
More informationDrug Testing Policy. Approved By 05/10/2017. Application This reimbursement policy applies to UnitedHealthcare Community Plan Medicaid products.
Policy Number 2017R6005B Annual Approval Date Drug Testing Policy 05/10/2017 Approved By Reimbursement Policy Oversight Committee IMPORTANT NOTE ABOUT THIS REIMBURSEMENT POLICY You are responsible for
More informationDrug Testing Policy. Reimbursement Policy CMS Approved By. Policy Number. Annual Approval Date. Reimbursement Policy Oversight Committee
Reimbursement Policy CMS 1500 Drug Testing Policy Policy Number 2018R6005A Annual Approval Date 07/11/2018 Approved By Reimbursement Policy Oversight Committee IMPORTANT NOTE ABOUT THIS REIMBURSEMENT POLICY
More informationHigh-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine
High-Throughput Quantitative LC-MS/MS Analysis of and 14 Benzodiazepines in Urine Bill Yu, Kristine Van Natta, Marta Kozak, Thermo Fisher Scientific, San Jose, CA Application Note 588 Key Words Opiates,
More informationDETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS
FORENSICS AND TOXICOLOGY ANALYSIS DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS Solutions for Your Analytical Business Markets and Applications
More informationSupplementary Information. Effects of Perfluorooctanoic Acid on Metabolic Profiles in Brain and Liver of Mouse by a
Supplementary Information Effects of Perfluorooctanoic Acid on Metabolic Profiles in Brain and Liver of Mouse by a High-throughput Targeted Metabolomics Approach Nanyang Yu, Si Wei, *, Meiying Li, Jingping
More informationChallenges of implementing JCTLM methods in the routine Clinical Laboratories. R.J. Singh, Ph.D. Mayo Clinic
Challenges of implementing JCTLM methods in the routine Clinical Laboratories R.J. Singh, Ph.D. Mayo Clinic 100s of Millions of 25-OH Vitamin D test have been run. Total 25-OH Vitamin D test is not a useful
More informationChemical Metrology for Human Health Assessment
Chemical Metrology for Human Health Assessment Metrology and Physical Constants International School of Physics Enrico Fermi Stephen A. Wise Analytical Chemistry Division Material Measurement Laboratory
More informationXiaolei Xie, Marta Kozak. Thermo Fisher Scientific, 355 River Oaks Parkway, San Jose, CA Introduction
Comparison of Non-derivatization and Derivatization Tandem Mass Spectrometry Methods for Analysis of Amino Acids, Acylcarnitines, and Succinylacetone in Dried Blood Spots Xiaolei Xie, Marta Kozak Thermo
More informationSuccessful implementation of online SPE LC-MS/MS in the clinical research laboratory
Successful implementation of online SPE LC-MS/MS in the clinical research laboratory Martijn van Faassen, PhD student Prof. Dr. Ido Kema University Medical Center Groningen Department of Laboratory Medicine,
More informationAgilent 7700x ICP-MS
Agilent 7700x ICP-MS Metals analysis Mid ppt to low ppb detection range Option to detect in four different gas modes to gain optimum detection of multiple metals or interferences in a sample Autosampler
More informationRobust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS
TECHNICAL NOTE 21882 Robust extraction, separation, and quantitation of structural isomer steroids human plasma by SPE-UHPLC-MS/MS Authors Jon Bardsley 1, Kean Woodmansey 1, and Stacy Tremintin 2 1 Thermo
More informationMedical Policy Outpatient Drug Screening and Testing. No Prior Authorization X X
Medical Policy Outpatient Drug Screening and Testing Document Number: 030 Authorization required Commercial and Qualified Health Plans MassHealth No Prior Authorization X X Overview The purpose of this
More informationOverview. Introduction. Experimental. Cliquid Software for Routine LC/MS/MS Analysis
A Fast and Sensitive LC/MS/MS Method for the Quantification and Confirmation of 3 Benzodiazepines and Nonbenzodiazepine Hypnotics in Forensic Urine Samples Cliquid Software for Routine LC/MS/MS Analysis
More informationRun 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.
APPLICATIONS A Simple and Effective High ph LC/MS/MS Method for Determination of Underivatized Vitamin B1 and B6 in Human Whole Blood Ramkumar Dhandapani Technical Manager Ramkumar loves to write poems,
More informationComparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D
Comparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D Julie A. Horner 1, Marta Kozak 1, Subodh Nimkar 1, and August A. Specht 1 1 Thermo Fisher Scientific, San Jose,
More informationIntroduction. Etienne Cavalier*, Olivier Rousselle, Nunzio Ferrante, Agnes Carlisi, Caroline Le Goff and Jean-Claude Souberbielle.
DOI 1.1515/cclm-13-138 Clin Chem Lab Med 13; aop Etienne Cavalier*, Olivier Rousselle, Nunzio Ferrante, Agnes Carlisi, Caroline Le Goff and Jean-Claude Souberbielle Technical and clinical evaluation of
More informationDIAZYME PRODUCT LIST LIST INNOVATIONS IN CLINICAL DIAGNOSTICS
DIAZYME PRODUCT LIST LIST PRODUCT 2 14 INNOVATIONS IN CLINICAL DIAGNOSTICS About Diazyme Diazyme Laboratories is a Division of General Atomics located in Poway, California. Diazyme uses its proprietary
More informationFast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS
Fast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS Christophe Deckers, M.Sc. Sample prep Application Scientist Types of ``Interferences``
More informationFast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS
TECHNICAL NOTE 21883 Fast and easy separation of 23 drugs of abuse including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS Authors Kean Woodmansey 1, Jon Bardsley 1 and Stacy
More informationAmino Acid Methods: Present and Future. Claire Hart Sheffield Children s Hospital
Amino Acid Methods: Present and Future Claire Hart Sheffield Children s Hospital The Status Quo Questionnaire shows everybody using HPLC or ion-exchange amino acid analysers for routine quantitative services
More informationThe analysis of Glucocorticoid Steroids in Plasma, Urine and Saliva by UPLC/MS/MS
The analysis of Glucocorticoid Steroids in Plasma, Urine and Saliva by UPLC/MS/MS Brett McWhinney, Supervising Scientist, HPLC Section, Pathology Central, Pathology Queensland Overview 1. Overview of Pathology
More informationManual. Transfer step. Figure 1. Workflow comparison of manual phenylalanine assay and automated GSP Neonatal Phenylalanine assay
TECHNICAL NOTE GSP Neonatal Phenylalanine kit 3308-0010/3308-001B GSP Neonatal Phenylalanine kit (3308-0010/3308-001B) is a fully Introduction automated enzymatic assay for the GSP system. Optimized for
More information2013 Endocrine Function Testing Market in Germany: Hospitals, Commercial Labs, Physician Offices. Table of Contents
Introduction 2013 Endocrine Function Testing Market in Germany: Hospitals, Commercial Labs, Physician Offices Table of Contents Worldwide Market and Technology Overview A. Major Endocrine Function Tests
More informationMeeting the LC-MS needs of a highthroughput. laboratory. April 18 th. 10:00 [New York]/ 15:00 [London]
Meeting the LC-MS needs of a highthroughput clinical laboratory April 18 th 10:00 [New York]/ 15:00 [London] Meeting the LC-MS Needs of a High-Throughput Clinical Chemistry Laboratory With examples from
More informationImmunoCAP Systems. Optimized for allergy testing - Precision - Accuracy - Consistency
ImmunoCAP Systems Optimized for allergy testing - Precision - Accuracy - Consistency 1 The ImmunoCAP systems from Phadia offer an optimal allergy testing solution for every laboratory, regardless of testing
More informationAnalysis of 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 in Serum Using Ultra-performance Liquid Chromatography with Tandem Mass Spectrometry
Analysis of 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 in Serum Using Ultra-performance Liquid Chromatography with Tandem Mass Spectrometry Yong-Wha Lee Department of Laboratory Medicine and Genetics,
More informationFast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system
Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system Xiang He 1, Adrian Taylor 2 and Alexandre Wang 1 1 SCIEX, Redwood City, USA. 2 SCIEX, Concord,
More informationCardiac Assessment Controls
Bio-Rad Laboratories CARDIAC ASSESSMENT CONTROLS Cardiac Assessment Controls Value Assigned for Clinical Laboratory and Point of Care Test Systems Solving the Challenges of Troponin I Testing for the Central
More informationSERVICE SCHEDULE, FEES & GUIDELINES FOR SAMPLE SHIPMENT
SERVICE SCHEDULE, FEES & GUIDELINES FOR SAMPLE SHIPMENT ACYLCARNITINE PROFILE: PLASMA/SERUM, PKU CARD, WHOLE BLOOD Amount of sample: Plasma (heparinized is preferred, EDTA acceptable) or serum: 0.5 ml
More informationDrug Testing Policy. Approved By 06/14/2017
Drug Testing Policy Policy Number Annual Approval Date 06/14/2017 Approved By Oversight Committee IMPORTANT NOTE ABOUT THIS REIMBURSEMENT POLICY This policy is applicable to UnitedHealthcare Medicare Advantage
More informationA Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS
A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS Introduction Drug analysis from whole blood is gaining popularity due to a more complete measurement
More informationNeonatal Screening using Shimadzu LCMS- 8040
SEG- 2050 Application Note for The Analytical Scientist 11-13 Neonatal Screening using Shimadzu LCMS- 8040 Introduction The development of electrospray tandem mass spectrometry (LCMS/MS) in recent years
More information2017 Drug Screen Tests
2017 Drug Screen Tests The ABCs of Applying the CMS 2017 HCPCS Codes Written by: Karen D. Chappell, EJD, MBA, CIRCC, CPMA, CPC-I, CHC Terminology Immunoassay Qualitative Therapeutic Quantitative GC/MS
More informationAbsoluteIDQ Kit: Targeted Metabolomics Identification and Quantification
AbsoluteIDQ Kit: Targeted Metabolomics Identification and Quantification Accurate, Reproducible, Metabolomics Studies The word metabolome refers to the complete set of small molecule metabolites arising
More informationAnalytical Variability Among Methods for the Measurement of 25-Hydroxyvitamin D. Still Adding to the Noise
Analytical Variability Among Methods for the Measurement of 25-Hydroxyvitamin D Still Adding to the Noise Earle W. Holmes, PhD, 1 Jean Garbincius, 2 and Kathleen M. McKenna, MBA, MT 2 From the 1 Departments
More informationAnalytes, instrumentation and software for neonatal screening. Complete solutions for screening newborns
Analytes, instrumentation and software for neonatal screening Complete solutions for screening newborns w w w. p e r k i n e l m e r. c o m 1 Everything you need for efficient neonatal screening PerkinElmer
More informationStandardization and Certification of the ADVIA Centaur Vitamin D Total Assay
Standardization and Certification of the ADVIA Centaur Vitamin D Total Assay Authors: James Freeman Paul Sibley, PhD Neil Parker, MSc Ryan Spears Kimberly S. Wilson H. Roma Levy, MS Affiliations: Siemens
More informationExtraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis
Application Note AN782 Extraction of Multiple Mycotoxins from Grain Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis This application
More informationExtraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis
Application Note AN807 Extraction of Aflatoxin M From Infant Formula Using ISLUTE Myco Page Extraction of Aflatoxin M From Infant Formula Using ISLUTE Myco SPE Columns prior to LC-MS/MS Analysis This application
More informationDRUG TESTING POLICY. Policy Number: ADMINISTRATIVE T0 Effective Date: March 1, Related Policies None
DRUG TESTING POLICY UnitedHealthcare Oxford Reimbursement Policy Policy Number: ADMINISTRATIVE 259.3 T0 Effective Date: March 1, 2018 Table of Contents Page INSTRUCTIONS FOR USE... 1 APPLICABLE LINES OF
More informationCan glycated albumin assist in management of diabetes mellitus? Jasna Lenicek Krleza, PhD. Children s Hospital Zagreb, Croatia
Can glycated albumin assist in management of diabetes mellitus? Jasna Lenicek Krleza, PhD. Children s Hospital Zagreb, Croatia DIABETES MELLITUS COURSE SUBJECT 2001 2014 WHEN WE PREPARED PROGRAMME of THIS
More informationSeparation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column
Diamond Analytics Technical Note: T131-1 Separation of Vitamin D and Vitamin D Metabolites on FLARE C1 MM (Mixed Mode) HPLC Column Introduction In this technical note, the versatility of the diamond-based
More informationPhenylalanine. in cases of hyperphenylalaninemia and tetrahydrobiopterin deficiency
Evolving Methods for the Measurement of Phenylalanine A vital diagnostic marker and indicator for follow-up in cases of hyperphenylalaninemia and tetrahydrobiopterin deficiency Dr. Zoltan Lukacs Department
More informationProtein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates
Application Note Clinical Research Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates Authors Limian Zhao and Megan Juck Agilent Technologies, Inc. Abstract
More informationMEDICAL POLICY Drug Testing
POLICY: PG0069 ORIGINAL EFFECTIVE: 01/01/11 LAST REVIEW: 11/13/18 MEDICAL POLICY Drug Testing GUIDELINES This policy does not certify benefits or authorization of benefits, which is designated by each
More informationEnzymatic Analysis for Food and Feed
Enzymatic Analysis for Food and Feed Enzymatic tests are widely used as analytical tools for the analysis of food products such as fruit juices, wine or beer, dairy products, eggs and meat. Enzymatic test
More informationVitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid
Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid Application Note Clinical Research Authors Derick Lucas and Limian Zhao Agilent Technologies, Inc. Abstract Lipids from
More informationBeckman Coulter introduces Sentinel Pancreatic Amylase reagent and calibrator on AU Clinical Chemistry Analyzers
PREVIOUSLY RELEASED BREA, CALIF. (June 23, 2016) Beckman Coulter Diagnostics is pleased to announce the release of a new pancreas specific amylase assay. The Sentinel Pancreatic Amylase reagent and calibrator
More informationDRUG TESTING POLICY. Policy Number: ADMINISTRATIVE T0 Effective Date: October 1, Related Policies None
DRUG TESTING POLICY UnitedHealthcare Oxford Reimbursement Policy Policy Number: ADMINISTRATIVE 259.1 T0 Effective Date: October 1, 2017 Table of Contents Page INSTRUCTIONS FOR USE... 1 APPLICABLE LINES
More informationCollege of American Pathologists (CAP) GH2 Survey Data: (updated 12/09) 2009 GH2-B (fresh pooled samples) * = NGSP certified at the time of the survey
College of American Pathologists (CAP) GH2 Survey Data: (updated 12/09) The American Diabetes Association (ADA) recommends that laboratories use only HbA1c assay methods that have been NGSP certified and
More informationTherapeutic Drug Monitoring
Therapeutic Drug Monitoring news from the laboratory Pieter Vermeersch, Steven Pauwels, Matthijs Oyaert Laboratory Medicine, UZ Leuven Overview 1. Introduction 2. Analytical methods 3. Testing on dry blood
More informationExtraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis
Application Note AN784 Extraction of Multiple Mycotoxins from Nuts Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis This application note
More information