ZIVAK TECHNOLOGIES. Multitasker-LC Walk Away UHPLC Analyzer For LC-MS/MS

Size: px
Start display at page:

Download "ZIVAK TECHNOLOGIES. Multitasker-LC Walk Away UHPLC Analyzer For LC-MS/MS"

Transcription

1 ZIVAK TECHNOLOGIES Multitasker-LC Walk Away UHPLC Analyzer For LC-MS/MS

2 Clinical Diagnostic Market Roche, Siemens,Midray Abbott, Beckman Currrent Clinical Diagnostic Market Immunoassay, ELISA, RIA,FIA Sciex, Agilent, Thermo Shimadzu, Waters.. Clinical Diagnosis with LC-MS/MS and HPLC Gold Standart Methods WHY?

3 2. False positive samples, when the results of the reference assay (LC-MS/MS-total-D) were less than 40 nmol/l but one or more of the immunoassays gave greater than or equal to 40 nmol/l. State-of-the-Art Vitamin D Assays: A Comparison of Automated Immunoassays with Liquid Chromatography Tandem Mass Spectrometry Methods Christopher-John L. Farrell,1,2 Steven Martin,1 Brett McWhinney,3 Isabella Straub,4 Paul Williams,5 and Markus Herrmann1,4* Clinical Chemistry 58: (2012)

4 NIST USA Traceability Report for Different Technics for Vit D2-D3 (Zivak 243A and 243B)

5 Limitations of HPLC and LC-MS/MS For Routine Clinical Use Roche, Siemens,Midray Abbott, Beckman Currrent Clinical Diagnostic Market Immunoassay, ELISA, RIA,FIA %95-97 FUTURE Ready to Use Analysis Kits Automation and Barcode Reading Walk-away HPLC and LC-MS/MS Analysers Sciex, Agilent, Thermo Shimadzu, Waters.. Clinical Diagnosis with LC-MS/MS and HPLC Gold Standart Methods %3-5

6 LC-MS/MS vs Immunoassay Advantages Disadvantages MS/MS methods High Specificity High Sensitivity Lower Kit Costs Multiplexing Measurements High Throughput Non-Automated Qualified staff required The need of rigorous kit validation Automated Barcode Reading Direct injection from Vacu tube Higher maintenance cost (20 K USD / year) Higher owner capital cost (200 K USD / device) Immunoassay Automated No need for qualified staff Validated kits Affordable prices Better traceability (barcode readers, Online LIS connection) Low Specificity Low Sensitivity Higher Kit Costs High Potential for interference

7 LC-MS/MS vs Immunoassay Advantages Disadvantages Zivak Multitasker Automated LC-MS/MS System High Specificity High Sensitivity Lower Kit Costs Multiplexing Measurements High Throughput Non-Automated Qualified staff required The need of rigorous kit validation Automated Barcode Reading Direct injection from Vacutube Online LIS connection Higher maintenance cost (20 K USD / year) Higher owner capital cost (200 K USD / device) Immunoassay Automated No need for qualified staff Validated kits Affordable prices Better traceability (barcode readers, Online LIS connection) Low Specificity Low Sensitivity Higher Kit Costs High Potential for interference

8 Turn Your LC-MS/MS Instrument into Walk Away Clinical Analyzer Roche, Siemens, Midray Abbott, Beckman Currrent Clinical Diagnostic Market Immunoassay, ELISA, RIA,FIA Sciex, Agilent, Thermo Shimadzu, Waters.. Clinical Diagnosis with LC-MS/MS and HPLC Gold Standart Methods

9 Zivak Multitasker-LC OUR VISION Each LC-MS/MS will need an automated sample prep LC Zivak Multitasker Full Automated Sample Preparation and Injection System

10 Multitasker - LC with TandemGold MS Turkey

11 Multitasker - LC with Shimadzu 8040 MS India

12 Multitasker LC with Sciex 4500 MS Italy

13 Multitasker - LC with Thermo TSQ MS South Korea

14 HB-100 New Design 2017 The New HBA1c Analyser 1,5 min analysis time for HbA1c and HbF 6,0 min analysis time for A1c, F, A0, A2, S, C, D, E Variants Real walk-away system with unique modules

15 Zivak NEW VD-200 D2-D3 Analyser UHPLC System World s only Walk-Away 25-OH Vitamin D2-D3 UHPLC-UV System April-2016

16 HPLC and LC/MS/MS Kits 16

17 Kit Test Times (sample prep. + run time) Psychoactive Drugs Urine LC-MS/MS Analysis Kit Amino Acid Biological Fluids LC-MS/MS Analysis Kit PKU Serum LC-MS/MS Analysis Kit PKU Dried Blood Spots LC-MS/MS Analysis Kit Organic Acid Urine LC-MS/MS Analysis Kit Neonatal Screening Dried Blood Spots LC-MS/MS Analysis Kit Immunosuppressant Whole Blood LC-MS/MS Analysis Kit VMA HVA 5-HIAA Urine LC-MS/MS Analysis Kit Catecholamines Urine LC-MS/MS Analysis Kit Metanephrine Urine LC-MS/MS Analysis Kit Neurotransmitters in Urine LC-MS/MS Analysis Kit 25-Hydroxyvitamin D2-D3 Serum LC-MS/MS APCIAnalysis Kit Total Homocysteine Serum LC-MS/-MS Analysis Kit Hemoglobin A1c Whole Blood HPLC Analysis Kit Hemoglobin Variant Whole Blood HPLC Analysis Kit PKU Serum HPLC Analysis Kit PKU Dried Blood Spots HPLC Analysis Kit 25-Hydroxyvitamin D2-D3 Serum HPLC Analysis Kit Vitamin A-E Serum HPLC Analysis Kit 25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit 7 min 20 min 2 min 2 min 20 min 1.5 min 2 min 15 min 16 min 13 min 13 min 2 min 2.5 min 1.5 min 6.5 min 2 min 2 min 6 min 8 min 3 min

18 Matrix /IS Labeled Standarts,Controls and Calibrators. 18

19 Clinical HPLC Analysis Kits HbA1C in Whole Blood Hb Variant and ß-Thalassemia 25-OH Vitamin D2/D3 in Serum Phe, Tyr and Trp in Serum & Plasma and DBS

20

Distribuido en España por: INGENIERIA ANALITICA S.L Tel: Fax:

Distribuido en España por: INGENIERIA ANALITICA S.L Tel: Fax: Distribuido en España por: INGENIERIA ANALITICA S.L Tel: +34 902.45.6677 Fax: +34 902.46.6677 www.ingenieria-analitica.com inf@ingenieria-analitica.com FUTURANAYSIS About Zivak UNIQUE SOLUTION FROM ONE

More information

SCIEX Vitamin D 200M Assay for the Topaz System

SCIEX Vitamin D 200M Assay for the Topaz System The First FDA-Cleared LC-MS/MS Assay for Vitamin D SCIEX Vitamin D 200M Assay for the Topaz System The first FDA-cleared LC-MS/MS assay for Vitamin D Vitamin D is an important building block for human

More information

A High-throughput Mass Spectrometry Multiplexed Assay to Measure Insulin and C- peptide

A High-throughput Mass Spectrometry Multiplexed Assay to Measure Insulin and C- peptide A High-throughput Mass Spectrometry Multiplexed Assay to Measure Insulin and C- peptide Steven W. Taylor 1, Zhaohui Chen 1,2, Richard E. Reitz 1, Michael J. McPhaul 1, Nigel J. Clarke 1 1 Quest Diagnostics

More information

25-Hydroxyvitamin D assay performance. Graham Carter Imperial College

25-Hydroxyvitamin D assay performance. Graham Carter Imperial College 25-Hydroxyvitamin D assay performance Graham Carter Imperial College www.deqas.org Outline of Talk 1. DEQAS: Organization and Objectives 2. Mean Assay Bias and Precision 3. Bias of individual samples

More information

Nutrition: obtaining reliable biomarker data to study the health status of populations

Nutrition: obtaining reliable biomarker data to study the health status of populations Nutrition: obtaining reliable biomarker data to study the health status of populations Christine M. Pfeiffer, Ph.D. Chief, Nutritional Biomarkers Branch, DLS AAAS 2011 Annual Meeting Science Without Borders

More information

PKU (Phenylketonuria) Serum LC-MS/MS Analysis Kit User Manual

PKU (Phenylketonuria) Serum LC-MS/MS Analysis Kit User Manual Page 1 / 24 PKU (Phenylketonuria) Serum LC-MS/MS Analysis Kit User Manual ZV-3003-0200-10 200 2-8 C Page 2 / 24 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. TEST PRINCIPLE...

More information

All stocks and calibration levels were prepared in water: methanol (50:50) v/v to cover range of all steroid concentrations (refer Table 1).

All stocks and calibration levels were prepared in water: methanol (50:50) v/v to cover range of all steroid concentrations (refer Table 1). Application LCMS-8040 Simultaneous determination of 11 steroids and Vitamin D2/D3 in human serum using LC/MS/MS - Introduction Quantification of endogenous hormonal steroids and their precursors is essential

More information

Disclosure: No conflict of interests to disclose

Disclosure: No conflict of interests to disclose Mei Chung, PhD MPH Assistant Professor Nutrition/Infection Unit, Department of Public Health and Community Medicine, School of Medicine, Tufts University 0 1 Disclosure: No conflict of interests to disclose

More information

An Introduction to the Use of itraq Reagents for Amino Acid Analysis

An Introduction to the Use of itraq Reagents for Amino Acid Analysis An Introduction to the Use of itraq Reagents for Amino Acid Analysis Lisa Sapp Clinical Research and Forensic Toxicology Product Manager Mass Spectrometry Systems Amino Acid Analysis Using itraq Reagents

More information

Cortisol Assays. The Good, The Bad and The Indifferent. David Ducroq. Cardiff and Vale ulhb WEQAS. Unit 6, Parc Tŷ Glas. Llanishen.

Cortisol Assays. The Good, The Bad and The Indifferent. David Ducroq. Cardiff and Vale ulhb WEQAS. Unit 6, Parc Tŷ Glas. Llanishen. Cortisol Assays The Good, The Bad and The Indifferent David Ducroq Cardiff and Vale ulhb WEQAS Unit 6, Parc Tŷ Glas Llanishen Cardiff www.weqas.com Summary Brief overview of current methods and challenges

More information

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

Mass Spectrometry Made Simple for Clinical Diagnostic Labs Mass Spectrometry Made Simple for Clinical Diagnostic Labs The SCIEX Topaz System with FDA-Cleared Topaz Vitamin D 200M Assay Kit Mass Spectrometry Made Simple SCIEX Topaz System for Clinical Diagnostics

More information

Abstract. Introduction

Abstract. Introduction A Fast Dilute-And-Shoot Method for Simultaneous 5-Hydroxyindoleacetic Acid (5-HIAA), Vanillylmandelic Acid (VMA), and Homovanillic Acid (HVA) LC-MS/MS Analysis in Human Urine By Shun-Hsin Liang and Sue

More information

Catecholamines and neurotransmitter. Comprehensive tools for routine and research

Catecholamines and neurotransmitter. Comprehensive tools for routine and research Catecholamines and neurotransmitter diagnostics Comprehensive tools for routine and research Neurotransmitters in human and animals Catecholamines and neurotransmitters play essential roles in both humans

More information

PKU (Phenylketonuria) Serum HPLC Analysis Kit User Manual

PKU (Phenylketonuria) Serum HPLC Analysis Kit User Manual Page 1 / 20 PKU (Phenylketonuria) Serum HPLC Analysis Kit User Manual ZV-4003-0200-10 200 2-8 C Page 2 / 20 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. TEST PRINCIPLE... 3

More information

Dayana Argoti, Kerry Hassell, Sarah J. Fair, and Joseph Herman Thermo Fisher Scientific, Franklin, MA, USA

Dayana Argoti, Kerry Hassell, Sarah J. Fair, and Joseph Herman Thermo Fisher Scientific, Franklin, MA, USA The Utilization of Novel Platform in a LC-MS/MS Workflow for the Analysis of Vitamin D, Testosterone, Immunosuppressants, Chemotherapeutics and Cortisol Dayana Argoti, Kerry Hassell, Sarah J. Fair, and

More information

Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation

Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation Valérie Thibert, Bénédicte Duretz Thermo Fisher Scientific, Courtaboeuf,

More information

Clinical Mass Spectrometry Case Studies: How we can Read Between the Lines

Clinical Mass Spectrometry Case Studies: How we can Read Between the Lines Clinical Mass Spectrometry Case Studies: How we can Read Between the Lines Alec Saitman Ph.D., DABCC (CC, TC) Director Special Chemistry and Toxicology Providence Regional Laboratories Disclosures None

More information

LC-MS/MS Challenges in a High-Throughput Clinical Chemistry Laboratory Michael Wright

LC-MS/MS Challenges in a High-Throughput Clinical Chemistry Laboratory Michael Wright LC-MS/MS Challenges in a High-Throughput Clinical Chemistry Laboratory Michael Wright SEALS Prince of Wales Hospital Randwick, NSW Clinical Chemistry From an Analytical Chemist Perspective How do you test

More information

LC-MS/MS Method for the Determination of Tenofovir from Plasma

LC-MS/MS Method for the Determination of Tenofovir from Plasma LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract

More information

Evaluation of the LIAISON 25 OH Vitamin D TOTAL Assay on the new LIAISON XL analyser

Evaluation of the LIAISON 25 OH Vitamin D TOTAL Assay on the new LIAISON XL analyser Evaluation of the LIAISON 25 OH Vitamin D TOTAL Assay on the new LIAISON XL analyser Prof. Etienne Cavalier Department of Clinical Chemistry University of Liège, CHU Sart-Tilman Liège, Belgium etienne.cavalier@chu.ulg.ac.be

More information

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring and in Urine Xiaolei Xie, Joe DiBussolo, Marta Kozak; Thermo Fisher Scientific, San Jose, CA Application Note 627 Key Words, norbuprenorphine,

More information

Fully automated sensitive determination of immunosuppressant drugs in whole blood, using high quality internal standardization

Fully automated sensitive determination of immunosuppressant drugs in whole blood, using high quality internal standardization PO-CON1773E Fully automated sensitive determination of immunosuppressant drugs in whole blood, using high quality internal standardization ASMS 2017 ThP-086 Marc FERNANDEZ 1, Aurore JAFFUEL 1, Fanny DAYOT

More information

Procedure for Toxicology Analysis Version 7 Toxicology Unit Effective Date: 03/14/2014 Issued by Drug Chemistry Forensic Scientist Manager

Procedure for Toxicology Analysis Version 7 Toxicology Unit Effective Date: 03/14/2014 Issued by Drug Chemistry Forensic Scientist Manager Toxicology Analysis 1.0 Purpose - This procedure specifies the required elements for analyzing toxicology submissions and reporting drug testing results. 2.0 Scope This procedure applies to all submissions

More information

DIRECT ENZYMATIC HbA1c ASSAY

DIRECT ENZYMATIC HbA1c ASSAY DIRECT ENZYMATIC HbA1c ASSAY ACCURATE AND SIMPLE DIAZYME INNOVATIONS IN CLINICAL DIAGNOSTICS About Diazyme Diazyme Laboratories is a Division of General Atomics located in Poway, California. Diazyme uses

More information

25 OH Vitamin D Rapid test

25 OH Vitamin D Rapid test INSTRUCTION FOR USE REF:GDB 7120-25T 25 OH Vitamin D Rapid test Rapid Whole Blood Vitamin D Test A Rapid Sandwich Immunochromatographic Test for the Quantitative Detection of total 25-OH Vitamin D in human

More information

Real-time PK Measurement of the Chemotherapeutic Drug Melphalan in Whole Blood by a Novel PaperSpray Mass Spectrometry

Real-time PK Measurement of the Chemotherapeutic Drug Melphalan in Whole Blood by a Novel PaperSpray Mass Spectrometry Palm Springs, California February 21-25 Real-time PK Measurement of the Chemotherapeutic Drug Melphalan in Whole Blood by a Novel PaperSpray Mass Spectrometry Junfang Zhao, Chandra Sharat, Parinda A. Mehta,

More information

25 OH Vitamin D Rapid Test

25 OH Vitamin D Rapid Test INSTRUCTION FOR USE REF:GDB 7120-25T 25 OH Vitamin D Rapid Test A Rapid Sandwich Immunochromatographic Test for Quantitative Detection of total 25-OH Vitamin D in human finger-prick blood For In Vitro

More information

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis The Investigation of Factors Contributing to Immunosuppressant Drugs Variability in LC-MS/MS Analysis Joseph Herman, Dayana Argoti, and Sarah Fair Thermo Fisher Scientific, Franklin, MA, USA Overview Purpose:

More information

Neonatal Screening using Shimadzu LCMS-8040

Neonatal Screening using Shimadzu LCMS-8040 PO-CON1355E Neonatal Screening using Shimadzu LCMS-8040 HPLC 2013 BIOM-31 Stefano Zaza 1 ; G. La Marca 2 ; S.Malvagia 2 1 Shimadzu Italy, Milano, Italy 2 Mass Spectrometry and Pharmacology Laboratory,

More information

Use of a Tandem Mass Spectrometry Research Method for the Analysis of Amino Acids and Acylcarnitines in Dried Blood Spots

Use of a Tandem Mass Spectrometry Research Method for the Analysis of Amino Acids and Acylcarnitines in Dried Blood Spots Use of a Tandem Mass Spectrometry Research Method for the Analysis of Amino Acids and Acylcarnitines in Dried Blood Spots Xiaolei Xie and Marta Kozak Thermo Fisher Scientific, San Jose, CA, USA Application

More information

APCCMS2010 Hong Kong Jan th Applied Biosystems LCMSMS Industry Workshop. Dr Matthew Grigg Asia Pacific Marketing and Support Manager

APCCMS2010 Hong Kong Jan th Applied Biosystems LCMSMS Industry Workshop. Dr Matthew Grigg Asia Pacific Marketing and Support Manager APCCMS2010 Hong Kong Jan 14-16 th Applied Biosystems LCMSMS Industry Workshop Dr Matthew Grigg Asia Pacific Marketing and Support Manager 2 2010 Applied Biosystems LLC and MDS Inc. Joint Owners AB SCIEX

More information

Methodology Report Total 25-Hydroxyvitamin D Determination by an Entry Level Triple Quadrupole Instrument: Comparison between Two Commercial Kits

Methodology Report Total 25-Hydroxyvitamin D Determination by an Entry Level Triple Quadrupole Instrument: Comparison between Two Commercial Kits BioMed Volume 213, Article ID 27426, 5 pages http://dx.doi.org/1.1155/213/27426 Methodology Report Total 25-Hydroxyvitamin D Determination by an Entry Level Triple Quadrupole Instrument: Comparison between

More information

Maria João Mendes Mendonça Barreira Department of Health Promotion and Chronic Deseases, INSA

Maria João Mendes Mendonça Barreira Department of Health Promotion and Chronic Deseases, INSA Quantification of four immunosuppressant drugs by Liquid Chomatography-Tandem Mass Spectrometry using Direct Injection. Maria João Mendes Mendonça Barreira Department of Health Promotion and Chronic Deseases,

More information

Vitamin D A game changer for Clinical Laboratories

Vitamin D A game changer for Clinical Laboratories Vitamin D A game changer for Clinical Laboratories Michael Wright Clinical Chemistry and Endocrinology Department, SEALS Prince of Wales Hospital Sydney, Australia What is 25OH Vitamin D? 25OH Vitamin

More information

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual Page 1 / 14 Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual ZV-3051-0200-15 200 Page 2 / 14 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. TEST

More information

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA

More information

Discrepancy between Vitamin D Total Immunoassays due to Various Cross-reactivities

Discrepancy between Vitamin D Total Immunoassays due to Various Cross-reactivities J Bone Metab ;22:7-112 http://dx.doi.org/.105/jbm..22.3.7 pissn 2287-6375 eissn 2287-7029 Original Article Discrepancy between Vitamin D Total Immunoassays due to Various Cross-reactivities Jun Hyung Lee,

More information

Bio-Rad Laboratories. Hemoglobin Testing. VARIANT II Hemoglobin Testing System For HbA 1c

Bio-Rad Laboratories. Hemoglobin Testing. VARIANT II Hemoglobin Testing System For HbA 1c Bio-Rad Laboratories Hemoglobin Testing VARIANT II Hemoglobin Testing System For HbA 1c Bio-Rad CDM System CDM 5.1 VII Instrument Patient Report V2_A1c_NU Patient Data Sample ID: AD Patient ID: Name: Physician:

More information

Drug Testing Policy. Reimbursement Policy CMS Approved By. Policy Number. Annual Approval Date. Reimbursement Policy Oversight Committee

Drug Testing Policy. Reimbursement Policy CMS Approved By. Policy Number. Annual Approval Date. Reimbursement Policy Oversight Committee Reimbursement Policy CMS 1500 Drug Testing Policy Policy Number 2017R6005A Annual Approval Date 05/10/2017 Approved By Reimbursement Policy Oversight Committee IMPORTANT NOTE ABOUT THIS REIMBURSEMENT POLICY

More information

Lab Guide 2019 Metabolic Section Lab Guide

Lab Guide 2019 Metabolic Section Lab Guide Lab Guide 2019 Metabolic Section Lab Guide Quantitative Amino acids Plasma Plasma. Container/Tube: Preferred EDTA, Place immediately in ice. Acceptable: lithium heparin, sodium heparin. Patient preparation:

More information

Evidence Based HbA1c Accuracy. Sabrina Koetsier Medical Scientist RCPAQAP Chemical Pathology

Evidence Based HbA1c Accuracy. Sabrina Koetsier Medical Scientist RCPAQAP Chemical Pathology Evidence Based HbA1c Accuracy Sabrina Koetsier Medical Scientist RCPAQAP Chemical Pathology Fresh lycohaemoglobin This program is designed to assist laboratories to assess the accuracy of their hihba1c

More information

Improving the Accuracy of Hemoglobin A 1c. : Your Help Is Needed

Improving the Accuracy of Hemoglobin A 1c. : Your Help Is Needed Improving the Accuracy of Hemoglobin A 1c : Your Help Is Needed Kristina Jackson Behan, PhD, MT(ASCP) (Clinical Laboratory Sciences Program, University of West Florida, Pensacola, FL) DOI: 10.1309/RTVTWPYPTPA5YAGU

More information

25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual

25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual Page 1 / 12 25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual ZV-4027-0500-10 500 2-8 C Page 2 / 12 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. IVD SYMBOLS...

More information

HPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. First HPLC Analyzer to Aid in Diagnosis of Diabetes

HPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. First HPLC Analyzer to Aid in Diagnosis of Diabetes HPLC ANALYZER Gold Standard Accuracy by Ion-Exchange HbA1c First HPLC Analyzer to Aid in Diagnosis of Diabetes TOSOH BIOSCIENCE www.tosohbioscience.us HPLC ANALYZER HbA1c analysis in 1.6 minutes Direct

More information

Detection of Cannabinoids in Oral Fluid with the Agilent 7010 GC-MS/MS System

Detection of Cannabinoids in Oral Fluid with the Agilent 7010 GC-MS/MS System Application Note Forensics, Workplace Drug Testing Detection of Cannabinoids in Oral Fluid with the Agilent 7010 GC-MS/MS System Authors Fred Feyerherm and Anthony Macherone Agilent Technologies, Inc.

More information

Improving Benzodiazepine Immunoassay Sensitivity by Rapid Glucuronide Hydrolysis Technology

Improving Benzodiazepine Immunoassay Sensitivity by Rapid Glucuronide Hydrolysis Technology Improving Benzodiazepine Immunoassay Sensitivity by Rapid Glucuronide Hydrolysis Technology Pongkwan (Nikki) Sitasuwan, Margarita Marinova, and L. Andrew Lee Integrated Micro-Chromatography Systems, LLC

More information

Identification and Quantification of Psychedelic Phenethylamine 2C Series using SPE and LC-MS/MS

Identification and Quantification of Psychedelic Phenethylamine 2C Series using SPE and LC-MS/MS Identification and Quantification of Psychedelic Phenethylamine 2C Series using SPE and LC-MS/MS UCT Part Numbers: CSXCE106-Clean Screen XCEL I 130mg/6mL SLDA100ID21-3UM - Selectra DA HPLC column, 100

More information

Drug Testing Policy. Approved By 05/10/2017. Application This reimbursement policy applies to UnitedHealthcare Community Plan Medicaid products.

Drug Testing Policy. Approved By 05/10/2017. Application This reimbursement policy applies to UnitedHealthcare Community Plan Medicaid products. Policy Number 2017R6005B Annual Approval Date Drug Testing Policy 05/10/2017 Approved By Reimbursement Policy Oversight Committee IMPORTANT NOTE ABOUT THIS REIMBURSEMENT POLICY You are responsible for

More information

Drug Testing Policy. Reimbursement Policy CMS Approved By. Policy Number. Annual Approval Date. Reimbursement Policy Oversight Committee

Drug Testing Policy. Reimbursement Policy CMS Approved By. Policy Number. Annual Approval Date. Reimbursement Policy Oversight Committee Reimbursement Policy CMS 1500 Drug Testing Policy Policy Number 2018R6005A Annual Approval Date 07/11/2018 Approved By Reimbursement Policy Oversight Committee IMPORTANT NOTE ABOUT THIS REIMBURSEMENT POLICY

More information

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine High-Throughput Quantitative LC-MS/MS Analysis of and 14 Benzodiazepines in Urine Bill Yu, Kristine Van Natta, Marta Kozak, Thermo Fisher Scientific, San Jose, CA Application Note 588 Key Words Opiates,

More information

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS FORENSICS AND TOXICOLOGY ANALYSIS DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS Solutions for Your Analytical Business Markets and Applications

More information

Supplementary Information. Effects of Perfluorooctanoic Acid on Metabolic Profiles in Brain and Liver of Mouse by a

Supplementary Information. Effects of Perfluorooctanoic Acid on Metabolic Profiles in Brain and Liver of Mouse by a Supplementary Information Effects of Perfluorooctanoic Acid on Metabolic Profiles in Brain and Liver of Mouse by a High-throughput Targeted Metabolomics Approach Nanyang Yu, Si Wei, *, Meiying Li, Jingping

More information

Challenges of implementing JCTLM methods in the routine Clinical Laboratories. R.J. Singh, Ph.D. Mayo Clinic

Challenges of implementing JCTLM methods in the routine Clinical Laboratories. R.J. Singh, Ph.D. Mayo Clinic Challenges of implementing JCTLM methods in the routine Clinical Laboratories R.J. Singh, Ph.D. Mayo Clinic 100s of Millions of 25-OH Vitamin D test have been run. Total 25-OH Vitamin D test is not a useful

More information

Chemical Metrology for Human Health Assessment

Chemical Metrology for Human Health Assessment Chemical Metrology for Human Health Assessment Metrology and Physical Constants International School of Physics Enrico Fermi Stephen A. Wise Analytical Chemistry Division Material Measurement Laboratory

More information

Xiaolei Xie, Marta Kozak. Thermo Fisher Scientific, 355 River Oaks Parkway, San Jose, CA Introduction

Xiaolei Xie, Marta Kozak. Thermo Fisher Scientific, 355 River Oaks Parkway, San Jose, CA Introduction Comparison of Non-derivatization and Derivatization Tandem Mass Spectrometry Methods for Analysis of Amino Acids, Acylcarnitines, and Succinylacetone in Dried Blood Spots Xiaolei Xie, Marta Kozak Thermo

More information

Successful implementation of online SPE LC-MS/MS in the clinical research laboratory

Successful implementation of online SPE LC-MS/MS in the clinical research laboratory Successful implementation of online SPE LC-MS/MS in the clinical research laboratory Martijn van Faassen, PhD student Prof. Dr. Ido Kema University Medical Center Groningen Department of Laboratory Medicine,

More information

Agilent 7700x ICP-MS

Agilent 7700x ICP-MS Agilent 7700x ICP-MS Metals analysis Mid ppt to low ppb detection range Option to detect in four different gas modes to gain optimum detection of multiple metals or interferences in a sample Autosampler

More information

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS TECHNICAL NOTE 21882 Robust extraction, separation, and quantitation of structural isomer steroids human plasma by SPE-UHPLC-MS/MS Authors Jon Bardsley 1, Kean Woodmansey 1, and Stacy Tremintin 2 1 Thermo

More information

Medical Policy Outpatient Drug Screening and Testing. No Prior Authorization X X

Medical Policy Outpatient Drug Screening and Testing. No Prior Authorization X X Medical Policy Outpatient Drug Screening and Testing Document Number: 030 Authorization required Commercial and Qualified Health Plans MassHealth No Prior Authorization X X Overview The purpose of this

More information

Overview. Introduction. Experimental. Cliquid Software for Routine LC/MS/MS Analysis

Overview. Introduction. Experimental. Cliquid Software for Routine LC/MS/MS Analysis A Fast and Sensitive LC/MS/MS Method for the Quantification and Confirmation of 3 Benzodiazepines and Nonbenzodiazepine Hypnotics in Forensic Urine Samples Cliquid Software for Routine LC/MS/MS Analysis

More information

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1. APPLICATIONS A Simple and Effective High ph LC/MS/MS Method for Determination of Underivatized Vitamin B1 and B6 in Human Whole Blood Ramkumar Dhandapani Technical Manager Ramkumar loves to write poems,

More information

Comparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D

Comparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D Comparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D Julie A. Horner 1, Marta Kozak 1, Subodh Nimkar 1, and August A. Specht 1 1 Thermo Fisher Scientific, San Jose,

More information

Introduction. Etienne Cavalier*, Olivier Rousselle, Nunzio Ferrante, Agnes Carlisi, Caroline Le Goff and Jean-Claude Souberbielle.

Introduction. Etienne Cavalier*, Olivier Rousselle, Nunzio Ferrante, Agnes Carlisi, Caroline Le Goff and Jean-Claude Souberbielle. DOI 1.1515/cclm-13-138 Clin Chem Lab Med 13; aop Etienne Cavalier*, Olivier Rousselle, Nunzio Ferrante, Agnes Carlisi, Caroline Le Goff and Jean-Claude Souberbielle Technical and clinical evaluation of

More information

DIAZYME PRODUCT LIST LIST INNOVATIONS IN CLINICAL DIAGNOSTICS

DIAZYME PRODUCT LIST LIST INNOVATIONS IN CLINICAL DIAGNOSTICS DIAZYME PRODUCT LIST LIST PRODUCT 2 14 INNOVATIONS IN CLINICAL DIAGNOSTICS About Diazyme Diazyme Laboratories is a Division of General Atomics located in Poway, California. Diazyme uses its proprietary

More information

Fast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS

Fast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS Fast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS Christophe Deckers, M.Sc. Sample prep Application Scientist Types of ``Interferences``

More information

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS TECHNICAL NOTE 21883 Fast and easy separation of 23 drugs of abuse including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS Authors Kean Woodmansey 1, Jon Bardsley 1 and Stacy

More information

Amino Acid Methods: Present and Future. Claire Hart Sheffield Children s Hospital

Amino Acid Methods: Present and Future. Claire Hart Sheffield Children s Hospital Amino Acid Methods: Present and Future Claire Hart Sheffield Children s Hospital The Status Quo Questionnaire shows everybody using HPLC or ion-exchange amino acid analysers for routine quantitative services

More information

The analysis of Glucocorticoid Steroids in Plasma, Urine and Saliva by UPLC/MS/MS

The analysis of Glucocorticoid Steroids in Plasma, Urine and Saliva by UPLC/MS/MS The analysis of Glucocorticoid Steroids in Plasma, Urine and Saliva by UPLC/MS/MS Brett McWhinney, Supervising Scientist, HPLC Section, Pathology Central, Pathology Queensland Overview 1. Overview of Pathology

More information

Manual. Transfer step. Figure 1. Workflow comparison of manual phenylalanine assay and automated GSP Neonatal Phenylalanine assay

Manual. Transfer step. Figure 1. Workflow comparison of manual phenylalanine assay and automated GSP Neonatal Phenylalanine assay TECHNICAL NOTE GSP Neonatal Phenylalanine kit 3308-0010/3308-001B GSP Neonatal Phenylalanine kit (3308-0010/3308-001B) is a fully Introduction automated enzymatic assay for the GSP system. Optimized for

More information

2013 Endocrine Function Testing Market in Germany: Hospitals, Commercial Labs, Physician Offices. Table of Contents

2013 Endocrine Function Testing Market in Germany: Hospitals, Commercial Labs, Physician Offices. Table of Contents Introduction 2013 Endocrine Function Testing Market in Germany: Hospitals, Commercial Labs, Physician Offices Table of Contents Worldwide Market and Technology Overview A. Major Endocrine Function Tests

More information

Meeting the LC-MS needs of a highthroughput. laboratory. April 18 th. 10:00 [New York]/ 15:00 [London]

Meeting the LC-MS needs of a highthroughput. laboratory. April 18 th. 10:00 [New York]/ 15:00 [London] Meeting the LC-MS needs of a highthroughput clinical laboratory April 18 th 10:00 [New York]/ 15:00 [London] Meeting the LC-MS Needs of a High-Throughput Clinical Chemistry Laboratory With examples from

More information

ImmunoCAP Systems. Optimized for allergy testing - Precision - Accuracy - Consistency

ImmunoCAP Systems. Optimized for allergy testing - Precision - Accuracy - Consistency ImmunoCAP Systems Optimized for allergy testing - Precision - Accuracy - Consistency 1 The ImmunoCAP systems from Phadia offer an optimal allergy testing solution for every laboratory, regardless of testing

More information

Analysis of 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 in Serum Using Ultra-performance Liquid Chromatography with Tandem Mass Spectrometry

Analysis of 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 in Serum Using Ultra-performance Liquid Chromatography with Tandem Mass Spectrometry Analysis of 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 in Serum Using Ultra-performance Liquid Chromatography with Tandem Mass Spectrometry Yong-Wha Lee Department of Laboratory Medicine and Genetics,

More information

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system Xiang He 1, Adrian Taylor 2 and Alexandre Wang 1 1 SCIEX, Redwood City, USA. 2 SCIEX, Concord,

More information

Cardiac Assessment Controls

Cardiac Assessment Controls Bio-Rad Laboratories CARDIAC ASSESSMENT CONTROLS Cardiac Assessment Controls Value Assigned for Clinical Laboratory and Point of Care Test Systems Solving the Challenges of Troponin I Testing for the Central

More information

SERVICE SCHEDULE, FEES & GUIDELINES FOR SAMPLE SHIPMENT

SERVICE SCHEDULE, FEES & GUIDELINES FOR SAMPLE SHIPMENT SERVICE SCHEDULE, FEES & GUIDELINES FOR SAMPLE SHIPMENT ACYLCARNITINE PROFILE: PLASMA/SERUM, PKU CARD, WHOLE BLOOD Amount of sample: Plasma (heparinized is preferred, EDTA acceptable) or serum: 0.5 ml

More information

Drug Testing Policy. Approved By 06/14/2017

Drug Testing Policy. Approved By 06/14/2017 Drug Testing Policy Policy Number Annual Approval Date 06/14/2017 Approved By Oversight Committee IMPORTANT NOTE ABOUT THIS REIMBURSEMENT POLICY This policy is applicable to UnitedHealthcare Medicare Advantage

More information

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS Introduction Drug analysis from whole blood is gaining popularity due to a more complete measurement

More information

Neonatal Screening using Shimadzu LCMS- 8040

Neonatal Screening using Shimadzu LCMS- 8040 SEG- 2050 Application Note for The Analytical Scientist 11-13 Neonatal Screening using Shimadzu LCMS- 8040 Introduction The development of electrospray tandem mass spectrometry (LCMS/MS) in recent years

More information

2017 Drug Screen Tests

2017 Drug Screen Tests 2017 Drug Screen Tests The ABCs of Applying the CMS 2017 HCPCS Codes Written by: Karen D. Chappell, EJD, MBA, CIRCC, CPMA, CPC-I, CHC Terminology Immunoassay Qualitative Therapeutic Quantitative GC/MS

More information

AbsoluteIDQ Kit: Targeted Metabolomics Identification and Quantification

AbsoluteIDQ Kit: Targeted Metabolomics Identification and Quantification AbsoluteIDQ Kit: Targeted Metabolomics Identification and Quantification Accurate, Reproducible, Metabolomics Studies The word metabolome refers to the complete set of small molecule metabolites arising

More information

Analytical Variability Among Methods for the Measurement of 25-Hydroxyvitamin D. Still Adding to the Noise

Analytical Variability Among Methods for the Measurement of 25-Hydroxyvitamin D. Still Adding to the Noise Analytical Variability Among Methods for the Measurement of 25-Hydroxyvitamin D Still Adding to the Noise Earle W. Holmes, PhD, 1 Jean Garbincius, 2 and Kathleen M. McKenna, MBA, MT 2 From the 1 Departments

More information

Analytes, instrumentation and software for neonatal screening. Complete solutions for screening newborns

Analytes, instrumentation and software for neonatal screening. Complete solutions for screening newborns Analytes, instrumentation and software for neonatal screening Complete solutions for screening newborns w w w. p e r k i n e l m e r. c o m 1 Everything you need for efficient neonatal screening PerkinElmer

More information

Standardization and Certification of the ADVIA Centaur Vitamin D Total Assay

Standardization and Certification of the ADVIA Centaur Vitamin D Total Assay Standardization and Certification of the ADVIA Centaur Vitamin D Total Assay Authors: James Freeman Paul Sibley, PhD Neil Parker, MSc Ryan Spears Kimberly S. Wilson H. Roma Levy, MS Affiliations: Siemens

More information

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis Application Note AN782 Extraction of Multiple Mycotoxins from Grain Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis This application

More information

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis Application Note AN807 Extraction of Aflatoxin M From Infant Formula Using ISLUTE Myco Page Extraction of Aflatoxin M From Infant Formula Using ISLUTE Myco SPE Columns prior to LC-MS/MS Analysis This application

More information

DRUG TESTING POLICY. Policy Number: ADMINISTRATIVE T0 Effective Date: March 1, Related Policies None

DRUG TESTING POLICY. Policy Number: ADMINISTRATIVE T0 Effective Date: March 1, Related Policies None DRUG TESTING POLICY UnitedHealthcare Oxford Reimbursement Policy Policy Number: ADMINISTRATIVE 259.3 T0 Effective Date: March 1, 2018 Table of Contents Page INSTRUCTIONS FOR USE... 1 APPLICABLE LINES OF

More information

Can glycated albumin assist in management of diabetes mellitus? Jasna Lenicek Krleza, PhD. Children s Hospital Zagreb, Croatia

Can glycated albumin assist in management of diabetes mellitus? Jasna Lenicek Krleza, PhD. Children s Hospital Zagreb, Croatia Can glycated albumin assist in management of diabetes mellitus? Jasna Lenicek Krleza, PhD. Children s Hospital Zagreb, Croatia DIABETES MELLITUS COURSE SUBJECT 2001 2014 WHEN WE PREPARED PROGRAMME of THIS

More information

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column Diamond Analytics Technical Note: T131-1 Separation of Vitamin D and Vitamin D Metabolites on FLARE C1 MM (Mixed Mode) HPLC Column Introduction In this technical note, the versatility of the diamond-based

More information

Phenylalanine. in cases of hyperphenylalaninemia and tetrahydrobiopterin deficiency

Phenylalanine. in cases of hyperphenylalaninemia and tetrahydrobiopterin deficiency Evolving Methods for the Measurement of Phenylalanine A vital diagnostic marker and indicator for follow-up in cases of hyperphenylalaninemia and tetrahydrobiopterin deficiency Dr. Zoltan Lukacs Department

More information

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates Application Note Clinical Research Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates Authors Limian Zhao and Megan Juck Agilent Technologies, Inc. Abstract

More information

MEDICAL POLICY Drug Testing

MEDICAL POLICY Drug Testing POLICY: PG0069 ORIGINAL EFFECTIVE: 01/01/11 LAST REVIEW: 11/13/18 MEDICAL POLICY Drug Testing GUIDELINES This policy does not certify benefits or authorization of benefits, which is designated by each

More information

Enzymatic Analysis for Food and Feed

Enzymatic Analysis for Food and Feed Enzymatic Analysis for Food and Feed Enzymatic tests are widely used as analytical tools for the analysis of food products such as fruit juices, wine or beer, dairy products, eggs and meat. Enzymatic test

More information

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid Application Note Clinical Research Authors Derick Lucas and Limian Zhao Agilent Technologies, Inc. Abstract Lipids from

More information

Beckman Coulter introduces Sentinel Pancreatic Amylase reagent and calibrator on AU Clinical Chemistry Analyzers

Beckman Coulter introduces Sentinel Pancreatic Amylase reagent and calibrator on AU Clinical Chemistry Analyzers PREVIOUSLY RELEASED BREA, CALIF. (June 23, 2016) Beckman Coulter Diagnostics is pleased to announce the release of a new pancreas specific amylase assay. The Sentinel Pancreatic Amylase reagent and calibrator

More information

DRUG TESTING POLICY. Policy Number: ADMINISTRATIVE T0 Effective Date: October 1, Related Policies None

DRUG TESTING POLICY. Policy Number: ADMINISTRATIVE T0 Effective Date: October 1, Related Policies None DRUG TESTING POLICY UnitedHealthcare Oxford Reimbursement Policy Policy Number: ADMINISTRATIVE 259.1 T0 Effective Date: October 1, 2017 Table of Contents Page INSTRUCTIONS FOR USE... 1 APPLICABLE LINES

More information

College of American Pathologists (CAP) GH2 Survey Data: (updated 12/09) 2009 GH2-B (fresh pooled samples) * = NGSP certified at the time of the survey

College of American Pathologists (CAP) GH2 Survey Data: (updated 12/09) 2009 GH2-B (fresh pooled samples) * = NGSP certified at the time of the survey College of American Pathologists (CAP) GH2 Survey Data: (updated 12/09) The American Diabetes Association (ADA) recommends that laboratories use only HbA1c assay methods that have been NGSP certified and

More information

Therapeutic Drug Monitoring

Therapeutic Drug Monitoring Therapeutic Drug Monitoring news from the laboratory Pieter Vermeersch, Steven Pauwels, Matthijs Oyaert Laboratory Medicine, UZ Leuven Overview 1. Introduction 2. Analytical methods 3. Testing on dry blood

More information

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis Application Note AN784 Extraction of Multiple Mycotoxins from Nuts Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis This application note

More information