Relative motion sensors
|
|
- Imogene Curtis
- 6 years ago
- Views:
Transcription
1 Relative motion sensors
2 Approvals DISPLACEMENT TRANSDUCERS Name Operating measurement range Output signal Operating frequency range, Hz Operating temperature range, С Explosion protection level Page in catalogue IKV--4- (axial shift) 0,5-,75 mm 0,5-5,5 mm 5,5-9,5 mm,0-9,0 mm current loop ExiallCT6 (, DS-, DS-3) 0ExiallCT5 (measuring unit) 4 IKV--3- (vibration displacement peak-to-peak) 0-00 µm 0-50 µm µm µm µm current loop ExiallCT6 (, DS-, DS-3) 0ExiallCT5 (measuring unit) 6, 8 IKV--4-. (speed of rotation, mark detection) IKV multi-purpose (axial shift, displ. pk-to-pk, rpm, mark detecting) RPM 0-50 µm µm µm 0,5-,75 mm 0,5-5,5 mm 5,5-9,5 mm,0-9,0 mm RPM current loop 4-0 ма current loop ; 0-0 V; RS ExiallCT6 (, DS-, DS-3) 0ExiallCT5 (measuring unit) 0ExiallCT6 (, DS-, DS-3) 0ExiallCT5 (measuring unit) 0
3 4-0 ESD User-friendly Design having built-in preamplifier and detachable joint allows for connection of any standard cable. Communication link length is up to 700 meters. Reliability The channel includes (DS-, DS-3) eddy-current probe, AS4 (in measuring unit), or AS4 on connecting cable. If measured parameters are required to be displayed, a display unit (DU) is provided optionally. The measuring unit can locate up to 6 display units. AS4 preamplifier AS 4 Display unit Measuring unit for version V IKV--4- vibration measuring channel IKV--4- is designed to measure axial shift in Emergency Shut-Down (ESD) systems; Output signal type: (4-0) ma Specifications Metrological parameters Axial shift measurement range (distance), mm with eddy-current probe ,5-,75 with DS- eddy-current probe ,5-5,5 with DS-3 eddy-current probe ,5-9,5(,0...9,0) Installation clearance (by default), mm ,5 ± 0, DS ,0 ± 0, DS ,5 (5) ± 0, Measurement cycle time, s w/ jumper ,0005 w/o jumper Electric resistance of insulation between electrical circuits of and its casing at 5±0ºC and relative humidity max. 90% non-condensing (min., Mohm) Interface Output signal current loop Power supply voltage, V (min. supply source voltage is 0V, +V per each 50 Ohm) Explosion protection Type intrinsically safe circuit (DS-, DS-3) marking EхiaIICT6 Measuring unit marking EхiaIICT5 Connection through safety barrier through TIK-PLC * controller * controller acts as ESD, power source and safety barrier Performance data Operating temperature range of DS-x in T6 temperature class environment, С Design parameters Mounting type М0х threaded hole DS М6х threaded hole DS М4х threaded hole Dimensions (excl. cable), mm eddy-current probe D(8,5) L(50;70;90) DS- eddy-current probe d(4,5) L(90) DS-3 eddy-current probe D(,5) L(95,4) AS x8x59 display unit х8х47 measuring unit х7х84 Weight (excl. cable) (max., kg) eddy-current probe ,35 DS- eddy-current probe ,40 DS-3 eddy-current probe ,50 AS4/AS , measuring unit ,50 Protection rating DS-х eddy-current probe IP67 AS IP0 per ГОСТ 454 measuring unit IP66 Modifications IKV--4- ver. А (DS-x ver.00(0), AS4, measuring unit) IKV--4- ver. B (DS-x ver.0 with AS4 on the cable, measuring unit) IKV--4- ver. V (DS-x ver.0 with AS4 on the cable, measuring unit, display unit) Reliability and manufacturer warranties Mean time between failures, hours, no less than Guaranteed service life, month Lifetime, years, no less than
4 БИ БИ БИ КАНАЛ КАНАЛ КАНАЛ 3 КАНАЛ 4 КАНАЛ 5 КАНАЛ БИ БИ DV-K БИ DV-K Configurations Eddy-current probes: (DS-, DS-3) Type А, ver. 0 Connecting Cable М0х () М6х (DS-) M4x (DS-3) AS 4 Male connector РМГБ0ШЕБ +U (0) 0 (+U) Contact, 9, 0 Cable female connector РМДБ0ШЕБ +U (0) 0 (+U) ХS Contact, 9, 0 0 ХР Ø30 L (50, 70, 90, 00) 000±0 L +U Measuring unit (ver. V) Display Unit (DU) (for IKV--4- ver. V) Display unit Аппаратура виброизмерительная ИКВ ИСКРОБЕЗОПАСНЫЕ ЦЕПИ,5 упр. инф. БИ Transducer Преобразователь AS 4 AS 4 XT Вибро- (DS-, преобра- зователь DS-3) vibration (DS-, type DS-3) A ver. 0 (исп. 0) 0ExiаIICT6 Terminal зажим with bolt ЗБХ and clip Channel components connection diagram Конт. Hazardous area Цепь, 3,4 Ur Measuring Блок измерительный unit Конт. +U 0 Цепь SW SW 3 IN КР. (Ж) СЕР. (Б) Ur 4 XT Цепь Конт. 0ExiаIICT5 Hazardous area Measuring unit Intrinsically safe grounding BIS-- safety barrier IN P Safe area IN P +4 V [Exib]IIC Safe area BIS-- safety barrier E R H R H E Loading range, Ohm: 00<(R H, R H)<400 Eddy-current probe mounting (DS-, DS-3) Axial shift determination Axial shift measurement range (0,5-,75)mm; DS- (0,5-5,5)mm; DS-3 (5,5-9,5)/(,0-9,0)mm Machine component intended for mounting Installation clearance =,5 mm; DS-=3,0 mm; DS-3=5,5 (5,0) mm 8 mm shift Shaft,5±0, mm Ж 0 mm (DS-, DS-3) vibration type A ver. 0 0ExiаIICT6 Terminal with bolt and clip,9 +U,0 0 XT +U Ur 0 0ExiаIICT5 Intrinsically safe grounding IN P +4 V [Exib]IIC E R H R H E Loading range, Ohm: 00<(R H, R H)<400 4 mm Target surface ЦRa0,8 ЦRa0,4 Order example: IKV--4-; type A ver. 00 L90; 6 meter cable. Shaft
5 4-0 ESD diagnostic Safety Breakdown and short circuit control of the cable connecting eddy-current probe with AS3. Reliability The channel includes (DS-, DS-3) eddy-current probe, the AS3 (in measuring unit), or AS3 on connecting cable. AS 3 Measuring unit IKV--3- vibration measuring channel is designed to measure vibration displacement peak-to-peak in diagnostic and ESD systems; Output signal type: (4-0)mA Specifications Metrological parameters Peak-to-peak displacement measurement range, µm , 0-50 DS , DS Installation clearance (by default, mm) ± 0, DS (,5) ± 0, DS ± 0, Measurement frequency range of displacement pk-to-pk, Hz Electric resistance of insulation between electrical circuits of and its casing at 5±0ºC and relative humidity max. 90% non-condensing (min., Mohm) Interface Output signal current loop Power supply voltage, V (min. supply source voltage is 0V, +V per each 50 Ohm) Explosion protection Type intrinsically safe circuit (DS-, DS-3) marking EхiaIICT6 Measuring unit marking EхiaIICT5 Connection through safety barrier through TIK-PLC * controller *controller acts as ESD, power source and safety barrier Performance data Operating temperature range of DS-x in T6 temperature class environment, С Design parameters Mounting type М0х threaded hole DS М6х threaded hole DS М4х threaded hole Dimensions (excl. cable), mm eddy-current probe D(8,5) L(50;70;90) DS- eddy-current probe D(4,5) L(90) DS-3 eddy-current probe D(,5) L(95,4) AS х8х59 display unit х8х47 measuring unit х7х84 Weight (excl. cable), max., kg eddy-current probe ,35 DS- eddy-current probe ,40 DS-3 eddy-current probe ,50 AS3/AS ,0 measuring unit ,50 Protection rating DS-х eddy-current probe IP67 AS IP0 per ГОСТ 454 measuring unit IP66 Modifications IKV--3- ver. А (DS-x ver.00(0), AS3, measuring unit) IKV--3- ver. B (DS-x ver.0 with AS3 on the cable, measuring unit) Reliability and manufacturer warranties Mean time between failures, hours, no less than Guaranteed service life, month Lifetime, years, no less than
6 R Configurations Eddy-current probe: (DS-, DS-3) type А, ver. 00 AS 3 M0x () M6x (DS-) M4x (DS-3) L(50, 70, 90, 00) L±0* (S) (grey, white) (central core) (red, yellow) 59 4,5 ХТ ХТ Eddy-current probe: (DS-, DS-3) type А, ver. 0 M0x () M6x (DS-) M4x (DS-3) L (50, 70, 90, 00) Connector РМД8БПЭ4Г Contact (central core), (shield) 3, 4 ХS Connecting cable L Measuring unit Male РМДТ8КПЭ4Ш5ВВ Contact (central core), (shield) 3, 4 L±0* ХР (S) (grey, white) (central core) (red, yellow) 7,5 SW SW IN 3 4 исп.0 Uo : 6,8 В Io : 0 ма Lo : 0, мгн Сo : 0,0 мкф ИКВ--3- AS 3 мм/с Гц 98,5 0 г. Ui : 4 В Ii : 0 ма Li : 0, мгн Сi : 0,0 мкф ХТ ХТ Amplifier 3 4 AS 3/ (DS-) SW SW IN +U 0 Ui, Ii, Li, Ci, U0, I0, L0, Amplifier C 0, V ma mh ufd V ma mh ufd AS , 0,0 6,8 0 0, 0,0 Channel components connection diagram Hazardous area Safe area +U 0 Measuring unit BIS-- safety barrier AS 3 7 ø7 4 holes AS 3 vibration type A ver. 00 XT 0 +U SW SW 3 IN Ur 4 XT IN P +4 V E E R H R H 0ExiаIICT6 0ExiаIICT5 [Exib]IIC Intrinsically safe grounding Loading range, Оhm: 00<(R H, R H)<400 Typical installation diagram Machine component intended for mounting Target surface 8 mm ЦRa0,8 ЦRa0,4 Order example: IKV--3-; type A ver. 00 L90; 6 meter cable.,0±0, mm Ж 0 mm Shaft vibration type A ver. 0 0ExiаIICT6 Hazardous area, 3,4 Ur Measuring unit Ur 4 AS 3 XT 0 +U SW SW 3 IN XT 0ExiаIICT5 Intrinsically safe grounding Safe area BIS-- safety barrier IN P +4 V [Exib]IIC R H E R H E Loading range, Оhm: 00<(R H, R H)<400
7 IKV--3- configurations for compressors Type B eddy-current probe ,7* 73, *customized for particular sizes
8 IKV--3- configurations for compressors Type С eddy-current probe * Type С eddy-current probe * 40 Type D eddy-current probe 0 40 L* 40 *customized for particular sizes
9 4-0 ESD User-friendly Design having built-in preamplifier and detachable joint allows for connection of any standard cable. Communication link length is up to 700 meters. Reliability The channel includes (DS-, DS-3) eddy-current probe, AS4 (in measuring unit), or AS4 on connecting cable. If measured parameters are required to be displayed, a display unit (DU) is provided optionally. The measuring unit can locate up to 6 display units. Preamplifier AS4 AS 4 Display unit Measuring unit for version V IKV--4-. vibration measuring channel IKV--4-. is designed to measure speed of rotation (factory mode) and to detect mark in the ESD Output signal type: (4-0) ma Specifications Metrological parameters Max. range of revolution speed measurement (RPM*) Speed measurement conversion ratio (no jumper mounted), ma/rpm*mm ¹* ,00 Installation clearance (by default, mm) ,5 DS ,0 DS ,5 (5,0) Mark detection measurement cycle time, ms Electric resistance of insulation between electrical circuits of and its casing at 5±0ºC and relative humidity max. 90% non-condensing, min., Mohm Interface Output signal current loop Power supply voltage, V (min. supply source voltage is 0V. +V per each 50 Ohm) Explosion protection Type intrinsically safe circuit (DS-, DS-3) marking EхiaIICT6 Measuring unit marking EхiaIICT5 Connection through safety barrier through TIK-PLC ** controller **controller acts as ESD, power source and safety barrier Performance data Operating temperature range of DS-x in T6 temperature class environment, С *may be modified upon customer's request Design parameters Mounting type М0х threaded hole DS М6х threaded hole DS М4х threaded hole Dimensions (excl. cable), mm eddy-current probe D(8,5) L(50;70;90) DS- eddy-current probe D(4,5) L(90) DS-3 eddy-current probe D(,5) L(95,4) AS x8x59 display unit х8х47 measuring unit х7х84 Weight (excl. cable), max., kg eddy-current probe ,35 DS- eddy-current probe ,40 DS-3 eddy-current probe ,50 AS4/AS , measuring unit ,50 Protection rating DS-х eddy-current probe IP67 AS IP0 per ГОСТ 454 measuring unit IP66 Modifications IKV--4-. ver. А (DS-x ver.00(0), AS4, measuring unit) IKV--4-. ver. B (DS-x ver.0 with AS4 on the cable, measuring unit) IKV--4-. ver. V (DS-x ver.0 with AS4 on the cable, measuring unit, display unit) Reliability and manufacturer warranties Mean time between failures, hours, no less than Guaranteed service life, month Lifetime, years, no less than
10 R Конструктивные Configurations исполнения Eddy-current probes: (DS-, DS-3) Type А, ver. 0 AS 4 M0x () M6x (DS-) M4x (DS-3) Male РМДТ8КПЭ4Ш5ВВ Contact (central core), (shield) 3, 4 ХР 4,5 ХТ ХТ L (50, 70, 90) L±0* 59 Connector РМД8БПЭ4Г Contact (central core), (shield) 3, 4 Connecting cable ХS L (S) (grey, white) (central core) (red, yellow) 7,5 SW SW IN 3 4 исп.0 Uo : 6,8 В Io : 0 ма Lo : 0, мгн Сo : 0,0 мкф ИКВ--4-. ИКВ--3- AS 3 4 мм/с Гц 0 г. Ui : 4 В Ii : 0 ма Li : 0, мгн Сi : 0,0 мкф 98,5 +U 0 Measuring unit AS 4 Схема Channel подключения components элементов connection канала diagram Hazardous area Safe area Measuring unit BIS-- safety barrier 7 AS 4 Eddy-current Типовая схема probe установки mounting (DS-, DS-3) Shaft (DS-, DS-3) vibration type A ver. 00 0ExiаIICT6 XT XT Цепь Конт. 0 +U SW SW 3 IN Ur 4 0ExiаIICT5 IN P +4 V [Exib]IIC R H E R H E Determination of rotational speed and mark detecting Mark Hazardous area Intrinsically safe grounding Safe area Loading range, Оhm: 00<(R H, R H)<400 Machine component intended for mounting Installation clearance =,5 mm; DS-=3,0 mm; DS-3=5,0 (5,5) mm 8 mm,0±0, mm 3 mm 5 mm Ж 0 mm (DS-, DS-3) vibration type A ver. 0 0ExiаIICT6, 3,4 Ur Measuring unit Ur 4 AS 4 XT 0 +U SW SW 3 IN XT 0ExiаIICT5 BIS-- safety barrier IN P +4 V [Exib]IIC R H E R H E Intrinsically safe grounding Loading range, Оhm: 00<(R H, R H)<400 Mark 4 mm Target surface ЦRa0,8 ЦRa0,4 Shaft Order example: IKV--4-.; type A ver. 00 L90; 6 meter cable.
11 4-0 ПАЗ диагностика All-in-one Ability to monitor rotational speed, operate in phase marker mode, measure working surface clearance, and vibration displacement peak-to-peak Reliability The channel includes (DS-, DS-3) eddy-current probe and AS3-V (in measuring unit). If measured parameters are required to be displayed, a display unit (DU) is provided optionally. AV 3-V Measuring unit IKV vibration measuring channel multi-purpose is designed to measure vibration displacement peak-to-peak, rotational speed, axial shift and detect marks in the vibration monitoring systems for rotary machinery; Output signal type: (4-0) ma, (0-0) V, Modbus RTU Specifications Metrological parameters Peak-to-peak displacement measurement range, µm eddy-current probe DS- eddy-current probe DS-3 eddy-current probe Clearance measurement range, mm eddy-current probe ,5-,75 DS- eddy-current probe ,5-5,5 DS-3 eddy-current probe ,5-9,5 Range of revolution speed measurement (RPM) Sampling frequency of phase marker, khz Measurement cycle time, sec ,0000 Rotational speed measurement error, % over 0.0 to of max. measurement range value below 0.0 of max. measurement range value Clearance measurement accuracy, µm for ±50 for DS ±00 for DS ±300 Pk-to-Pk measurement error, % over 0.0 to of max. vibration acceleration value below 0.0 of max. vibration acceleration value Installation clearance (by default), mm eddy-current probe ,5 ± 0, DS- eddy-current probe ,0 ± 0, DS-3 eddy-current probe ,5(5) ± 0, Interface Output signal current loop V Modbus RTU (RS-485) Power supply voltage, V Explosion protection Type intrinsically safe circuit (DS-, DS-3) marking EхiaIICT6 Measuring unit marking EхiaIICT5 Performance data Operating temperature range, С vibration AV3-V Design parameters Mounting type М0х threaded hole DS М6х threaded hole DS М4х threaded hole Dimensions (excl. cable), mm eddy-current probe D(8,5) L(50;70;90) DS- eddy-current probe D(4,5) L(90) eddy-current probe D(,5) L(95,4) display unit х8х47 measuring unit х7х84 Weight (excl. cable), max., kg eddy-current probe ,35 DS- eddy-current probe ,40 DS-3 eddy-current probe ,50 measuring unit ,50 Protection rating DS-х eddy-current probe IP67 measuring unit IP66 Reliability and manufacturer warranties Mean time between failures, hours, no less than Guaranteed service life, month Lifetime, years, no less than
12 *5007* TIK Research & Production Enterprise, Limited Liability Company 4A, Marii Zagummennykh St., Perm, 64067, Russia Tel./Fax+7 (34) , Web-site: tik.perm.ru
Relative motion sensors
Relative motion sensors DISPLACEMENT TRANSDUCERS Name Operating measurement range Output signal Operating frequency range, Hz Operating temperature range, С Explosion protection level Page in catalogue
More informationLION. Application Note PRECISION. Linear Position Measurement with Eddy-Current Sensors. LA March, Applicable Equipment: Applications:
LION PRECISION Application Note LA02-0061 March, 2013 Linear Position Measurement with Eddy-Current Sensors Position, Displacement Applicable Equipment: Eddy-Current position measurement systems. Applications:
More informationTechnical Tip: How to Connect and Troubleshoot Transducer Feedback. Product(s): iqpump1000 and iqpump Micro Drives
This Technical Tip assists users in applying Yaskawa iqpump1000 and iqpump Micro products to pump systems and provides useful information on: running without a transducer fixing Fdb-L or Feedback Loss
More informationTechnical Data Sheet SONOFLOW CO.55 V1.0
Technical Data Sheet SONOFLOW CO.55 V1.0 The sensor series SONOFLOW CO.55 V1.0 designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a
More informationTEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP
TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL 1 2 Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...
More informationWith extended functionality the sensors are also applicable for the detection of air bubbles.
Technical Data Sheet The sensor series designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a few milliseconds. With extended functionality
More informationDescription. Specifications and Ordering Information Proximitor Sensor / interface module/ VDC Housings
Specifications and Ordering Information Proximitor Sensor / interface module/ VDC Housings R Description Although Proximitor and interface are rugged by design, these units and their electrical connections
More informationTechnical support: +49 (0)7223 /
ISO 9001 certified Technical support: +49 (0)7223 / 9493-0 Technical description ADDIVARIOUS PX 901 Screw terminal board 8 th edition 08/2000 Copyright All rights reserved. This manual is intended for
More informationINSTRUCTION MANUAL (MAN-70254)
INSTRUCTION MANUAL (MAN-70254) CLEVELAND-KIDDER ULTRA SERIES UNDER PILLOW BLOCK TRANSDUCER MODELS: UPB1 & UPB2 REVISION AA Industrial Products Division 7550 Hub Parkway Cleveland, Ohio 44125 Phone: 216.524.8800
More informationTechnical Data Sheet SONOFLOW CO.55/xxx(H) V2.0
The sensor series SONOFLOW CO.55/xxx V2.0 designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a few milliseconds. For applications on
More informationSignet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems
Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems Features Certificate of calibration supplied with all sensors. Universal Mount Custom cell constant programmed into the electronics.
More informationPROFIBUS Products Overview P PROFIBUS Converter/Repeater P PROFIBUS Gateway P6-3-1
.1. Overview P-1-1.2. PROFIBUS Converter/Repeater P-2-1.3. PROFIBUS Gateway P-3-1.4. PROFIBUS Remote I/O Modules P-4-1.5. PROFIBUS I/O Unit P-5-1 Overview.1. Overview PROFIBUS (Process Field Bus) is a
More informationCerus P-Series General Specifications Section 15172
Cerus P-Series s Section 15172 Variable Frequency Drives PART 1-GENERAL 1.01 SECTION INCLUDES A. Variable Frequency Drive(VFD) 1.02 RELATED SECTIONS A. Section 16195 1.03 REFERENCES A. NEMA250 B. EN 50178
More informationWNK5 Series High Precision Pressure Transmitter
WNK5 Series High Precision Pressure Transmitter WNK5 series pressure transmitter is the high performance pressure transmitters provided by nhui WNK Electronic Engineering Co., Ltd. It transforms the physical
More informationJEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA
JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA TYPICAL APPLICATIONS All general loads, indoors or outdoors, including lighting, industrial & commercial Schools Hospitals Factories Office
More informationSignet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor
Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Features Test certificate supplied with all sensors Universal Mount Custom cell constant programmed into the
More informationGoniometer series 400
User s Manual Huber Diffraktionstechnik GmbH & Co. KG Sommerstrasse 4 D - 83253 Rimsting Phone +49 (0) 8501 6878-0 Fax +49 (0) 8051 6878-10 info@xhuber.com www.xhuber.com series 400 Manual 400_en-A05 2005
More informationE200 ORT - Optical Rotary Torque Transducer. Contents
E200 ORT - Optical Rotary Torque Transducer Contents Optical Rotary Torque Transducer [E200 ORT]: TSE2038R Rotary Torque Transducer Installation Guide: TS3001J Optical Rotary Torque Transducer [E200 ORT]
More informationThe Do s and Don ts of Pressure Transducers
The Do s and Don ts of Pressure Transducers ABSTRACT When specifying a pressure transducer for a process measurement, a number of items have to be considered. Some of the more important ones are discussed
More informationSystem Multiplexer / Permissive Module
System Multiplexer / (Cat 2030-MLXxxx-SYSx) ATTETIO: Hazardous Voltage or other forms of energy could be present. To avoid serious injury or death: rior to beginning the installation and wiring process,
More informationSPECIFICATION GUIDE. Phoenix EX AC Drive Closed Loop AC Vector Control 3 HP to 3500 HP 200 to 600 VAC Input
US Drives Inc. 2221 Niagara Falls Boulevard P.O. Box 281 Niagara Falls, NY 14304-0281 Tel: (716) 731-1606 Fax: (716) 731-1524 Visit us at www.usdrivesinc.com GUIDE Phoenix EX AC Drive Closed Loop AC Vector
More informationProduct reference. LV switch-disconnectors 3. Product panorama 9. Functions and characteristics 17. Installation and connection 47
Product reference LV switch-disconnectors 3 Product panorama 9 Functions and characteristics 17 Installation and connection 47 Technical details 71 IS40 to 160 78 IS250 to 630 80 IV100 to 630 (visible
More informationSide Channel R ing Blower
Side Channel R ing Blower ------------------------------------- INSTRUCTION MNUL ------------------------------------ RB20../ 30../ 40../ 50../ 60 / 80.. SERIES CONTENT PGE 1. SFETY REQUIREMENT... 1 2.
More informationAC CENTRIFUGAL FORWARD CURVED FAN 133 x 190
Micromotori Elettrici Svizzera Motor Type AC CENTRIFUGAL FORWARD CURVED FAN 133 x 19 Code: 3.9775 Project code: Poles Stator Impeller Type -4 V 5/6 Hz ~ 1 1 M35 Centrifugal Forward Curved Blade double
More information(all beam angles defined as, -3dB or half power inclusive)
Transducers Transducers: Standard Range Encapsulated ATEX ( EEx m) for zones 1 and 2 as standard On NPT threaded versions, FM Class I, Div 1, Group A, B, C and D. Class II, Div 1, Group E, F and G. Class
More informationRDP/DDP REDUNDANT/DUPLEX DRIVE PACKAGE
RDP/DDP REDUNDANT/DUPLEX DRIVE PACKAGE USER MANUAL Franklin Control Systems 11/11/2013 Table of Contents 1. Safety precautions... 1 2. Legends & Introduction... 2 3. Installation and wiring... 3 4. Setup...
More informationDigital Dentistry Solution
Digital Dentistry Solution Digital Dentistry Solution 02 Digital Dentistry Solution CAD/CAM System Mill - Clinic Optimized for glass-ceramic High speed and steady quality in milling Simple and elegant
More informationMicroSwitcher TMS Series 6, 10, 15, 25 Watt
Features Ultraminiature AC/DC Switching Power Supply Modules Fully encapsulated Plastic Package Universal Input 85-264 VAC, 50/60 Hz High Efficiency Low Ripple and Noise Overload Protection EMI meets EN
More informationTEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP
TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...
More informationLiquid level transmitter Type AKS 41 / 41U REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Liquid level transmitter Type AKS 41 / 41U REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3
More informationLexium 05 Servo Drives. Motion control The high concentrate solution for your machines
Lexium 05 Servo Drives Motion control The high concentrate solution for your machines Lexium 05 Servo Drives Leveraging ingenuity and intelligence for ease of use Top grade performance With this new generation
More informationRLS/E-EV MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES
The RLS/E-EV MX series of burners covers a firing range from 350 to 2400 kw, and they have been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil
More informationFittings & Accessories
Fittings & Accessories Adalet offers a range of fittings and accessories for use in general purpose or industrial locations. These fittings and accessories are used in conjunction with our industrial electrical
More informationMechanical Vibration Causes, Effect, Analysis & Prevention Techniques
Training Title Mechanical Vibration Causes, Effect, Analysis & Prevention Techniques Training Duration 5 days Training Date Ref ME125 Mechanical Vibration Causes, Effect, Analysis & Prevention Techniques
More informationDefining Cutting Edge Quality. Laser Cutting Head BIMO-FSC
Defining Cutting Edge Quality Laser Cutting Head BIMO-FSC Optical System Perfectly Focused on Highest Productivity The BIMO-FSC s optical system is set-up modularly. This provides different options for
More informationOIML R 122 Annex C RECOMMENDATION. Edition 1999 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION
INTERNATIONAL RECOMMENDATION OIML R 122 Annex C Edition 1999 (E) Equipment for speech audiometry Annex C Test report format Appareils pour l audiométrie vocale Annexe C Format du rapport d essai OIML R
More informationTHS74/75 Industrial Temperature & Humidity Transmitter. Operation Manual
THS74/75 Industrial Temperature & Humidity Transmitter Operation Manual 1. Features 2. Security considerations 3. Installation 4. Connection 5. Display and LED instruction 6. Software setting and calibration
More informationDescription The 4000 Series offers up to 8600 in-lb of torque and 25 gpm (continuous ratings). This is the corner stone of the Char-Lynn line.
Highlights Features ety of mounting flanges and output shafts options Benefits motor into a system tough applications Applications Description The 0 Series offers up to 0 in-lb of torque and gpm (continuous
More informationSWITCHGEAR PBD. fuse bases
SWITCHGEAR PBD fuse bases designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links ENERGY SAFELY SWITCHED SWITCHGEAR
More informationSWITCHGEAR PBD. fuse bases
SWITCHGEAR PBD fuse bases designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links ENERGY SAFELY SWITCHED SWITCHGEAR
More informationSignet 2850 Conductivity/Resistivity Sensor Electronics * *
Signet 850 Conductivity/Resistivity Sensor Electronics *-850.090-* English -850.090- Rev. H 06/ English SAFETY PRECAUTIS. Depressurize and vent system prior to installation or removal.. Confi rm chemical
More informationWhen worker safety is mission critical. Thermo Scientific EPD TruDose Electronic Dosimeter
When worker safety is mission critical. Thermo Scientific EPD TruDose Electronic Dosimeter For over 25 years, Thermo Scientific EPD s have set the standard for trusted radiological performance in electronic
More informationDefining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC
Defining Cutting Edge Quality Laser Cutting Head BIMO-FSC BIMO-FSC Modules 40 Laser light cable receiver Cover slide in front of collimation 9 46,5 0,2 86,5 64,4 2,5 131,2 Collimation module with manual
More informationCANADA SENSORS TECHNOLOGY INC.
CANADA SENSORS TECHNOLOGY INC. Manufacturer of Advanced Technology Pressure & Level Transmitters PRESSURE TRANSMITTER PROCESS 1 HART Enabled Intrinsically Safe Model Canada Sensors intelligent transmitters
More informationArmstrong IVS 102 Drive Specification
Armstrong IVS 102 Drive Specification Part I: General Description 1. This specification covers complete variable frequency drives (VFDs) designated on the drawing schedules to be variable speed. All standard
More informationPHYSICAL THERAPY. Combination therapy. Laser therapy. Traction therapy MAGCELL. Electrotherapy. Shockwave therapy. Cryotherapy.
GENERAL CATALOGUE PHYSICAL THERAPY Laser therapy Traction therapy MAGCELL Electrotherapy Shockwave therapy Cryotherapy vocastim Ultrasound therapy Shortwave therapy Magnetotherapy Vacuum application Microwave
More informationNOE LOBBY RANGE NOE LOBBY C - 1/2 hrs CMV/Collective extraction units Flow rate 400 to m 3 /h COLLECTIVE VENTILATION
COLLECTIVE VENTILATION NOE LOBBY RANGE NOE LOBBY 4 4 C - 1/2 hrs CMV/Collective extraction units Flow rate 4 to 114 m 3 /h 4 4 COLLECTIVE VENTILATION Ventilation unit PULLEY/BELT TRANSMISSION 4 to 114
More informationTSH Series, 2 Watt. 12 VDC 165 ma 82 % TSH 1212D ±12 VDC ±80 ma 82 % TSH 1215D ±15 VDC ±65 ma 82 % TSH 2405S 5 VDC 400 ma 78 % TSH 2412S 24 VDC ±10%
TSH Series, 2 Watt Features Ultra compact SMD package (SOIC-14/18) Isolated single and dual output models I/O isolation 1 000 VDC High efficiency up to 82% Operating temperature 40 C to +85 C Reflow solder
More informationThere are many varieties of particulate pollutants in our homes and offices. Ones from outside include industrial
Model: IAQ Indoor PM2.5 -PM2.5 Particulate matter (PM) is a particle pollution, which is produced in a great number of ways that can be classified into either mechanical or chemical processes. Traditionally,
More informationRiGO801 Laboratory Requirements
RiGO801 Laboratory Requirements 2015-11-25 Air Conditioning According to EN 13032 1 and LM-79-08 the temperature in the environment of the DUT needs to be 25 C +/- 1 C during the measurement. EN 13032-4
More informationTC65B, WG6. IEC Industrial Process Control Systems Guideline for evaluating process control systems. Micaela Caserza Magro Paolo Pinceti
COMITATO ELETTROTECNICO ITALIANO TC65B, WG6 IEC 62603 Industrial Process Control s Guideline for evaluating process control systems Micaela Caserza Magro Paolo Pinceti The origin of the idea F UK Group
More informationRLS /M MX SERIES
The RLS/M MX series of burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above
More informationScrew Compressor Pulsation & Vibration
Case Histories Screw Compressor Pulsation & Vibration Ethan Clark, Signet Monitoring & Analysis Inc. June 2017 Windrock User Group The Whole Story The Myths Screw compressors are pulsation & vibration
More informationGyroscope. The gyroscope apparatus could easily malfunction or produce incorrect results. It should be treated with extra care.
General Physics Lab Department of PHYSICS YONSEI University Lab Manual (Lite) Gyroscope Ver.20180419 NOTICE This LITE version of manual includes only experimental procedures for easier reading on your
More information2YEARS. three-phase kVA. Digital voltage stabiliser Orion Plus. Standard features. Voltage stabilisation PC selectable output voltage
«WARRANTY«WARRANTY«WARRANTY«WARRANTY 2YEARS Digital stabiliser Standard features Voltage stabilisation PC selectable output Independent phase control Frequency 50/60Hz ±5% Admitted load variation Up to
More informationE-Link Gateway Installation Instructions
E-Link Gateway Installation Instructions Issue Date December 3, 2007 E-Link Gateway Installation Instructions Applications The E-Link Gateway provides Johnson Controls and York mechanical equipment, such
More informationDefining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC
Defining Cutting Edge Quality Laser Cutting Head BIMO-FSC BIMO-FSC Laser Cutting Head BIMO-FSC for Flexible Flat Sheet Cutting The use of fibre lasers for cutting applications is growing steadily. The
More informationDEVICE FOR MUSCLE COORDINATION IMPROVEMENT
9th International DAAAM Baltic Conference "INDUSTRIAL ENGINEERING - 24-26 April 2014, Tallinn, Estonia DEVICE FOR MUSCLE COORDINATION IMPROVEMENT Gorordo, I.; Mäntylä, J.; Popkov, A.; Saastamoinen, J.;
More informationLiquid ring vacuum pumps single-stage
Liquid ring vacuum pumps single-stage LOH 20103, LOH 20107 Pressure range: Suction volume flow: 150 to 1013 mbar 7 to 58 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum pumps are displacement pumps
More informationVIAVI IFR6000 DME Mode Signal Generator Reply Pulse Width Output Frequency Echo Reply Output Level Reply Pulse Rise and Fall Times (all pulses)
Specification Sheet VIAVI IFR6000 Transponder/DME/TCAS Flight Line Test Set VIAVI Solutions DME Mode A 5-minute warm-up period is required for all specifications. Output Reply : 962 to 1213 MHz : Output
More informationMini UPS and Power Sensor. Power Output Cord. Power Input Port. Switch Port
AVTECH Mini UPS and Power Sensor AVTECH s Mini UPS and Power Sensor (MUPS) monitors the on/off state of a power source, such as main power, a UPS, surge protector or standard wall outlet, and also provides
More informationLexium 05 motion control
00 0 V single-phase supply voltage Servo drive/servo motor combinations Lexium 0A or 0B servo drive/brh or BSH servo motor combinations Servo motors Lexium 0A and 0B servo drives 00 0 V single-phase supply
More informationDescription The 4000 Series offers up to 8600 in-lb of torque and 25 gpm (continuous ratings). This is the corner stone of the Char-Lynn line.
Highlights Features displacements, a variety of mounting flanges and output shafts Reliable, proven design High efficiency Environmental protection options Benefits Flexiblilty in designing this motor
More informationTABLE OF CONTENTS. 2.0 USING MANAGER PREFERENCE 2.1 Using manager preference mode 2.2 Selecting US or metric 2.3 Using CSafe
E L L I P T I C A L T O T A L B O D O W N E R S M A N U A L TABLE OF CONTENTS 1.0 IMPORTANT SAFET INSTRUCTIONS Read and save these instructions Setting up the Elliptical total body 1.1 Installation requirements
More informationStandards. n Built in accordance with NEMA, ANSI, UL and CSA standards
Drive Isolation 4 3 to 990 kva Applications n For industrial and commercial applications with SCR-controlled adjustable speed motor drives, and AC adjustable frequency or DC drives Specifications n NEMA1
More informationRLS /M MX SERIES
RLS/M burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above all, more flexible.
More informationCONTENTS. page 2. page 2. page 3. page 4. page 5-7. page page 12 PRECAUTIONS OPERATING INSTRUCTION EXPLODED DRAWING PARTS LIST
CONTENTS PRECAUTIONS OPERATING INSTRUCTION EXPLODED DRAWING PARTS LIST ASSEMBLY INSTRUCTIONS MONITOR INSTRUCTION MANUAL WARRANTY INFORMATION page 2 page 2 page 3 page 4 page 5-7 page 8-11 page 12 1 PRECAUTIONS
More informationWe bring quality to light. LGS 350 Goniophotometer
We bring quality to light. LGS 350 Goniophotometer The features at a glance Type C goniophotometer with horizontal optical axis For samples up to max. 700 mm diameter and 8 kg weight Accurate determination
More informationAMS 200. Goniophotometer for small to medium-sized lamps and modules
AMS 200 Goniophotometer for small to medium-sized lamps and modules 02 \\ Equipment and function Ke features at a glance CIE Tpe A goniometer for small to medium-sized lamps and modules High-precision
More informationSignet 2850 Conductivity/Resistivity Sensor Electronics
Signet 850 Conductivity/Resistivity Sensor Electronics -850.090- -850.090- Rev. C 08/07 English ENGLISH SAFETY INSTRUCTIONS. Depressurize and vent system prior to installation or removal.. Confi rm chemical
More informationFundamentals of Pressure Transducers
print close Fundamentals of Pressure Transducers (Unpublished) Hydraulics & Pneumatics Alan Hitchcox Tue, 2013 09 17 (All day) Pressure is a key factor in almost every fluid power circuit. Pressure transducers
More informationLINESCAPES SYSTEM. Made in Italy
LINESCAPES SYSTEM LINESCAPES SYSTEM Made in Italy 03 Linescapes is a modular system that is completely changing the approach to high performance diffused direct and indirect lighting. The singular modules
More informationMost of the Conductivity/Resistivity electrodes used with the 2850 can be installed into standard 3 /4 in. (NPT or ISO 7-R 3 /4) fittings.
InLine Installation Most of the Conductivity/Resistivity electrodes used with the 850 can be installed into standard /4 in. (NPT or ISO 7R /4) fittings. The 8505X models are designed for integral systems,
More informationPROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. C PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
More informationDigital Dentistry Solution
Digital Dentistry Solution Digital Dentistry Solution 02 Digital Dentistry Solution CAD/CAM System Optimized for glass ceramic High speed and steady quality in milling Simple and elegant design Bar, Disk
More informationRLS /E-EV MX SERIES
RLS 300 800/E-EV MX SERIES RLS/E-EV MX series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier,
More informationAdvanced Research Systems, Inc.
4/17/01 Page 1 Huber Goniometer Interface 6.5K to 800K Closed Cycle Cryostat DESCRIPTION The DE-202G has been designed for applications requiring movement of the refrigerator, specifically for goniometers.
More informationVariable Frequency Drives
Variable Frequency Drives Date : Feb 09, 2015-07:30 AM - Feb 10, 04:30 PM Event URL : http:///events/variable-frequency-drives-feb-2015-rochester- Organizer : American Traincoâ Venue : Location : Rochester
More informationRLS/BP MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES. RLS 300/BP MX 600/ kw RLS 400/BP MX 800/ kw DUAL FUEL.
RLS/BP MX series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above all,
More informationEvolve 3 & 5 Service Manual
Evolve 3 & 5 Service Manual 1 Product Browse 2 Contents CHAPTER 1: SERIAL NUMBER LOCATION... 5 CHAPTER 2: CONSOLE INSTRUCTIONS 2.1 Console Overview... 6 2.1.1 Evolve 3 Console Overview... 6 2.1.2 Evolve
More informationMINISTAR DIGITAL AND CONTROL /// The new compact stirrers
30 /// OVERHEAD STIRRERS OVERHEAD STIRRERS MICROSTARS 31 IKA offers the ideal overhead stirrer for your stirring and mixing tasks in the lab for low to high viscosities. IKA overhead stirrers effortlessly
More informationStrain Gage Measurements
Strain Gage Measurements Strain Gage Measurements Strain gauge measurements The electrical resistance strain gauge technique is based on measuring the variation in electrical resistance undergone by a
More informationPHYSICAL THERAPY. Combination therapy. Laser therapy. Traction therapy MAGCELL. Electrotherapy. Shockwave therapy. Cryotherapy.
GENERAL CATALOGUE PHYSICAL THERAPY Laser therapy Traction therapy MAGCELL Electrotherapy Shockwave therapy Cryotherapy vocastim Ultrasound therapy Shortwave therapy Magnetotherapy Vacuum application Microwave
More informationThe comparison between the acquisition vibration data obtained by different types of transducers for hydraulic turbine head cover
Journal of Physics: Conference Series PAPER OPEN ACCESS The comparison between the acquisition vibration data obtained by different types of transducers for hydraulic turbine head cover To cite this article:
More informationAUTOMATIONWORX. User Manual. UM EN IBS SRE 1A Order No.: INTERBUS Register Expansion Chip IBS SRE 1A
AUTOMATIONWORX User Manual UM EN IBS SRE 1A Order No.: 2888741 INTERBUS Register Expansion Chip IBS SRE 1A AUTOMATIONWORX User Manual INTERBUS Register Expansion Chip IBS SRE 1A 06/2006 Designation: Revision:
More informationWe bring quality to light. LGS 1000 Goniophotometer
We bring quality to light. LGS 1000 Goniophotometer Instrument description Measurement options Spatial radiation patterns Luminous flux integration Specifications Key features at a glance Goniophotometer
More informationMOBOTIX Product Announcement D14
MOBOTI Product Announcement D14 MOBOTI Product Announcement D14 1. Product Description 3 2. D14 Product Line 4 2.1. Product Image 4 2.2. Differences of D14 versus D12 6 2.3. Maximum Frame Rates 7 2.4.
More informationMEGGITT SENSING SYSTEMS Endevco short course guide
MEGGITT SENSING SYSTEMS Endevco short course guide Shock and vibration measurement technology I Shock and vibration measurement technology II Instructors: Jon Wilson, Jon S. Wilson Consulting Michael Phan,
More informationXstress 3000 G3/G3R. X-ray Stress Analyzer. Portable X-ray diffractometer specially designed for residual stress and retained austenite measurements
Xstress 3000 G3/G3R X-ray Stress Analyzer Portable X-ray diffractometer specially designed for residual stress and retained austenite measurements Xstress 3000 G3 measures residual stresses and retained
More informationBIADC. Computer Controlled Biomedical Auditory and Diagnostic Teaching Unit, with SCADA. Key features:
Engineering and Technical Teaching Equipment Computer Controlled Biomedical Auditory and Diagnostic Teaching Unit, with SCADA BIADC Teaching Technique used EDIBON SCADA System 2 Control Interface Box 3
More informationHOW TO USE THE SHURE MXA910 CEILING ARRAY MICROPHONE FOR VOICE LIFT
HOW TO USE THE SHURE MXA910 CEILING ARRAY MICROPHONE FOR VOICE LIFT Created: Sept 2016 Updated: June 2017 By: Luis Guerra Troy Jensen The Shure MXA910 Ceiling Array Microphone offers the unique advantage
More informationActive Imaging TM transducers: Active Imaging 3-IN-1 Active Imaging SideScan
Active Imaging TM transducers: Active Imaging 3-IN-1 Active Imaging SideScan Installation manual ENGLISH www.simrad-yachting.com www.lowrance.com 1 Preface Warning: It is your sole responsibility to install
More informationGRUNDFOS DATA BOOKLET. BM, BMhp. Booster Modules 50/60 Hz
GRUNDFOS DATA BOOKLET BM, BMhp Booster Modules 5/6 z BM, BMhp Table of contents 1. BM applications 4 Pumped liquids 4 2. BM product introduction 4 Standard pumps 4 Construction 4 Motor 4 3. BM, BMhp performance
More information3. Dimensions, weights Placement and Assembly Pressure drops Noise data Material... 14
These technical specifications state a row of manufactured sizes and models of smoke extraction dampers - single (further only dampers) SEDS-L. It is valid for production, designing, ordering, delivery,
More informationTC TC500-X...Proportional TC1000-X...Proportional TC500-D...3-Position TC1000-D...3-Position. Electric Actuator
Datasheet No.: TC500-02 TC500-X...Proportional TC000-X...Proportional TC500-D...3-Position TC000-D...3-Position Electric Actuator Suitable for valve stroke 20mm. Rating force 500N/000N TC500-X.../ TC000-X...
More informationPulmo Waves Device for respiratory physiotherapy
MADE IN ITALY Pulmo Waves Device for respiratory physiotherapy Respiratory physiotherapy Accumulation of secretions in certain parts of the human respiratory system can take place for different reasons.
More informationKeylock switches for PCB
lock switch for PCB General data lock switch for PCB mounting. Matching with the RS 76 full-travel keyswitch and the RF 15 and RF 19 short-travel keyswitch. Content lock switch IP5, MICROMEC - 18 lock
More informationThe Phalanx. Featuring Evolv DNA250 Technology. ***Keep Out of reach of children. This device is for persons 18yrs of age or older ***
The Phalanx Featuring Evolv DNA250 Technology ***Keep Out of reach of children. This device is for persons 18yrs of age or older *** Congratulations on your purchase of the Phalanx DNA250 temperature protected
More information5GHz Band SPDT Switch + LNA GaAs MMIC
5GHz Band SPDT Switch + LNA GaAs MMIC GENERAL DESCRIPTION The NJG1739K51 is a 5GHz band SPDT switch + low noise amplifier GaAs MMIC designed for wireless LAN front-end applications. The NJG1739K51 features
More information