2017 myresearch Science Internship Program: Applied Medicine. Civic Education Office of Government and Community Relations

Size: px
Start display at page:

Download "2017 myresearch Science Internship Program: Applied Medicine. Civic Education Office of Government and Community Relations"

Transcription

1 2017 myresearch Science Internship Program: Applied Medicine Civic Education Office of Government and Community Relations

2 Nevaeh Miller Science Internship Program: Applied Medicine

3 A Combined Spiral CT Scan of Sinus and the Brain May Alter the Amount of Radiation Delivered to the Patient Nevaeh Miller Frank Dong, PHD Ellen Park, MD

4 Abstract When performing CT Scans in pediatric patients for simple sinus and the brain, two different techniques are performed. An axial scan is utilized for a CT of the brain and a spiral scan is performed for a CT of the simple sinus. There is an overlap of scan around the orbits when performing both scans at the same time, however, radiation to the orbits should be minimized as the orbits are radiosensitive. Performing a CT scan utilizing a single spiral technique may change the overall radiation dose when compared to performing both a CT sequential scan through the brain and a CT spiral scan through the limited sinuses.

5 Background Traditionally, a CT of the brain is performed in sequential technique and a CT of the simple sinus is performed in spiral technique, covering only a limited amount of the sinus. In the outpatient setting, both CT of the brain and CT of the simple sinus may be ordered for the evaluation of headaches.

6 Background Computed Tomography Dose Index (CTDI) is a standardized dose metric for CT. CTDIvol represents the average dose across the field-of-view (FOV) in the mid-plane of the scanned volume for helical scans. DLP refers to Dose Length Product DLP = exposure length x CTDI vol DLP approximates the integrated dose along the scan range; therefore, clinically DLP is often used to indicate total energy deposited.

7 Problem/Purpose There is an overlap of radiation to the orbits when a pediatric patient receives separate CT scans of the brain and simple sinus at the same time. The purpose of the study was to evaluate radiation dose to the patient and orbits when performing CT scans of the brain and simple sinus with two different techniques using sequential and spiral versus one spiral technique, and compare the overall radiation doses.

8 Hypothesis Performing a CT of the brain and simple sinus utilizing the single spiral technique rather than sequential and spiral techniques may reduce radiation doses to the orbits and patient.

9 Methodology Experimented with a 16 cm diameter head phantom Performed a combined CT scan of the brain followed by another CT scan for sinus in single spiral technique Performed a separate CT scan of the brain in sequential technique Performed a separate CT scan for simple sinus in spiral technique Recorded the Computed Tomography Dose Index (CTDI) & recorded the Dose Length Product (DLP)

10

11 Data (cont.) All patients under 18 years old who had CT of the simple sinuses were first identified and there were 329 total. Of these patients, the patients who had both CT of brain and simple sinus on the same day were isolated which were 30 in total. The CTDI and DLP were recorded and added for both the CT of the brain and simple sinus.

12 Data (cont.) Name CTDI_Sinus DLP_Sinus CTDI_Brain DLP_Brain Patient Patient Patient Patient Patient Patient Patient Patient Patient Patient Patient Patient Patient Patient Patient Patient Patient Patient Patient Patient

13 Results A total of 5 patients between the ages of 0-5 years old were identified who received both CT of the brain and simple sinuses. The average CTDI of total brain + sinus in 0-5 year old patients was with mean of This average and mean CTDI vol is similar to that of the phantom imaging of 32.7 in the typical scenario.

14 Conclusions No significant difference in the amount of CTDI vol and Patient Orbit Dose was observed between the group of single spiral technique imaging of CT brain and simple sinus versus two different techniques of CT brain and CT simple sinus. This may be secondary to comparing CT of simple sinuses rather than CT of stereo sinus, which images the sinuses entirety as would be performed under single spiral CT of the brain and sinus

15 Recommendations Further study is needed to compare the radiation doses in studies where patients have received a stereo sinus procedure which is a procedure that makes it more easier for a physician to get a view of the sinus.

16 References Beale T, Brown J, Route J. ENT, neck and dental radiology. In: Adam A, Dixon AK, Gillard JH, Schaefer- Prokop CM, eds. Grainger & Allison's Diagnostic Radiology: A Textbook of Medical Imaging. 6th ed. New York, NY: Churchill Livingstone; 2014:chap 67. Shaw, A.S., Dixon, A.K. Multidetector computed tomography. In: Adam A, Dixon AK, eds. Grainger & Allison's Diagnostic Radiology: A Textbook of Medical Imaging. 5th ed. New York, NY: Churchill Livingstone; 2008:chap 4. Thomsen, H.S., Reimer, P. Intravascular contrast media for radiology, CT, and MRI. In: Adam A, Dixon AK, Gillard JH, Schaefer-Prokop CM, eds. Grainger & Allison's Diagnostic Radiology: A Textbook of Medical Imaging. 6th ed. New York, NY: Churchill Livingstone; 2014:chap 2. Walden, M.J., Zinreich, S.J., Aygun N. In: Flint PW, Haughey BH, Lund LJ, et al, eds. Cummings Otolaryngology: Head & Neck Surgery. 6th ed. Philadelphia, PA: Elsevier Mosby; 2015:chap 41. Menoch, M. J., Herish, D. A., Khan, N. S., Simon, H. K., & Sterm, J. J. (2012, March). Trends in Computed Tomography Utilization in the Pediatric Emergency Department. Retrieved July 17, 2017, from

17 Special Thanks Ellen Park, MD Frank Dong, PHD Darlene Bublavy Nedra Starling, MA, MPH, DrPH/ABD Cleveland Clinic Office of Government and Community Relations Department of Civic Education

18 Copyright 2017 Cleveland Clinic Foundation

2016 myresearch Science Internship Program: Radiology. Civic Education Office of Government and Community Relations

2016 myresearch Science Internship Program: Radiology. Civic Education Office of Government and Community Relations 2016 myresearch Science Internship Program: Radiology Civic Education Office of Government and Community Relations Kayla Siladi Science Internship Program: Radiology Pediatric Computed Tomography Scans

More information

2018 myresearch Science Internship Program: Health Horizons. Civic Education Office of Government and Community Relations

2018 myresearch Science Internship Program: Health Horizons. Civic Education Office of Government and Community Relations 2018 myresearch Science Internship Program: Health Horizons Civic Education Office of Government and Community Relations Amnerys Camacho Science Internship Program: Health Horizons Alternative Treatments

More information

State of the art and future development for standardized estimation of organ doses in CT

State of the art and future development for standardized estimation of organ doses in CT State of the art and future development for standardized estimation of organ doses in CT March 2015 William J. O Connel, Dr. Ph, Senior Medical Physicist Imagination at work. Agenda Introduction Duke Florida

More information

CT Dose Estimation. John M. Boone, Ph.D., FAAPM, FSBI, FACR Professor and Vice Chair of Radiology. University of California Davis Medical Center

CT Dose Estimation. John M. Boone, Ph.D., FAAPM, FSBI, FACR Professor and Vice Chair of Radiology. University of California Davis Medical Center CT Dose Estimation John M. Boone, Ph.D., FAAPM, FSBI, FACR Professor and Vice Chair of Radiology 1 University of California Davis Medical Center CT Dose Estimation Introduction The CTDI Family of Metrics

More information

2016 myresearch Science Internship Program: Laboratory Medicine. Civic Education Office of Government and Community Relations

2016 myresearch Science Internship Program: Laboratory Medicine. Civic Education Office of Government and Community Relations 2016 myresearch Science Internship Program: Laboratory Medicine Civic Education Office of Government and Community Relations Aliya Ansari Science Internship Program: Laboratory Medicine Cytologic Differentiation

More information

2016 myresearch Science Internship Program: Applied Medicine. Civic Education Office of Government and Community Relations

2016 myresearch Science Internship Program: Applied Medicine. Civic Education Office of Government and Community Relations 2016 myresearch Science Internship Program: Applied Medicine Civic Education Office of Government and Community Relations Nadia Paskert Science Internship Program: Applied Medicine Breast Reconstruction

More information

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery Comparison of radiation dose and imaging performance for the standard Varian x-ray tube and the Richardson Healthcare ALTA750 replacement tube for the Toshiba Aquillion CT scanners. by Robert L. Dixon,

More information

2015 myresearch Science Internship Program: Nursing Care. Civic Education Office of Government and Community Relations

2015 myresearch Science Internship Program: Nursing Care. Civic Education Office of Government and Community Relations 2015 myresearch Science Internship Program: Nursing Care Civic Education Office of Government and Community Relations Mary Chudy Science Internship Program: Nursing Care Patients with a Deep Brain Stimulator

More information

Patient / Organ Dose in CT

Patient / Organ Dose in CT Patient / Organ Dose in CT Patient specific and organ dose estimation H.D. Nagel Dr. HD Nagel, Science & Technology for Radiology Buchholz / Germany www.sascrad.com 1 Topics CTDI & patient dose SSDE Organ

More information

Spine MRI and Spine CT Test Request Tip Sheet

Spine MRI and Spine CT Test Request Tip Sheet Spine MRI and Spine CT With/Without Contrast CT, MRI Studies should NOT be ordered simultaneously as dual studies (i.e., with and without contrast). Radiation exposure is doubled and both views are rarely

More information

SPECIFIC PRINCIPLES FOR DOSE REDUCTION IN HEAD CT IMAGING. Rajiv Gupta, MD, PhD Neuroradiology, Massachusetts General Hospital Harvard Medical School

SPECIFIC PRINCIPLES FOR DOSE REDUCTION IN HEAD CT IMAGING. Rajiv Gupta, MD, PhD Neuroradiology, Massachusetts General Hospital Harvard Medical School SPECIFIC PRINCIPLES FOR DOSE REDUCTION IN HEAD CT IMAGING Rajiv Gupta, MD, PhD Neuroradiology, Massachusetts General Hospital Harvard Medical School OUTLINE 1 st Presentation: Dose optimization strategies

More information

Citation Hong Kong Practitioner, 1996, v. 18 n. 12, p

Citation Hong Kong Practitioner, 1996, v. 18 n. 12, p Title Radiological conference. Frontal sinus osteoma complicated by pneumocephalus Author(s) Fung, WT; Peh, WCG Citation Hong Kong Practitioner, 1996, v. 18 n. 12, p. 658-662 Issued Date 1996 URL http://hdl.handle.net/10722/44655

More information

Why is CT Dose of Interest?

Why is CT Dose of Interest? Why is CT Dose of Interest? CT usage has increased rapidly in the past decade Compared to other medical imaging CT produces a larger radiation dose. There is direct epidemiological evidence for a an increase

More information

Spine MRI and Spine CT Test Request Tip Sheet

Spine MRI and Spine CT Test Request Tip Sheet Spine MRI and Spine CT MRI is almost always preferred over CT scan; if ordering CT, CLEARLY document why MRI is not appropriate. In cases of back pain without red flags, six weeks of multimodality supervised

More information

2015 myresearch Science Internship Program: Applied Medicine. Civic Education Office of Government and Community Relations

2015 myresearch Science Internship Program: Applied Medicine. Civic Education Office of Government and Community Relations 2015 myresearch Science Internship Program: Applied Medicine Civic Education Office of Government and Community Relations Harguneet Singh Science Internship Program: Applied Medicine Comparisons of Outcomes

More information

Dose Metrics in the Patient Report: Myopic or Foresighted?

Dose Metrics in the Patient Report: Myopic or Foresighted? Dose Metrics in the Patient Report: Myopic or Foresighted? BEVERLEY NEWMAN M.B.B.CH FACR Professor Of Radiology, Stanford University, Lucile Packard Children s Hospital, Palo Alto, CA Background: California

More information

CURRENT CT DOSE METRICS: MAKING CTDI SIZE-SPECIFIC

CURRENT CT DOSE METRICS: MAKING CTDI SIZE-SPECIFIC CURRENT CT DOSE METRICS: MAKING CTDI SIZE-SPECIFIC Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine Acknowledgments John Boone, PhD Michael McNitt-Grey,

More information

Spine MRI and Spine CT Test Request Tip Sheet

Spine MRI and Spine CT Test Request Tip Sheet Spine MRI and Spine CT With/Without Contrast CT, MRI The study considered best for a specific clinical scenario should be ordered. The second study should be done ONLY if the first study does not provide

More information

Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use?

Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use? Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use? Eva Godske Friberg * Norwegian Radiation Protection Authority, P.O. Box, Østerås, Norway Abstract.

More information

Downloaded from tumj.tums.ac.ir at 17:29 IRDT on Friday March 22nd 2019

Downloaded from tumj.tums.ac.ir at 17:29 IRDT on Friday March 22nd 2019 8-22 387 2 66 8 :.... (radiofrequency palatoplasty) :.. non randomized prospective quasi-experimental.( ) 2 :.. 2 BMI. %57. 25-65 (SD=/7) 47. %7/4.(SD=4/5)...(p=/5).(p

More information

Pediatric Imaging Spine MRI and Spine CT Test Request Tip Sheet

Pediatric Imaging Spine MRI and Spine CT Test Request Tip Sheet Pediatric Imaging Spine MRI and Spine CT MRI is almost always preferred over CT scan; if ordering CT, CLEARLY document why MRI is not appropriate. In cases of ongoing back pain, six weeks of conservative

More information

CT Head Dose Reduction Using Spiral Scanning Protocol

CT Head Dose Reduction Using Spiral Scanning Protocol CT Head Dose Reduction Using Spiral Scanning Protocol Reed, William J MD; Broderick, Daniel F, MD; Weindling, Steven M, MD; Czervionke, Leo F MD; and Morin, Richard L; PhD; Mayo Clinic, Department of Radiology;

More information

Pediatric Imaging Spine MRI and Spine CT Test Request Tip Sheet

Pediatric Imaging Spine MRI and Spine CT Test Request Tip Sheet Pediatric Imaging Spine MRI and Spine CT MRI is almost always preferred over CT scan; if ordering CT, CLEARLY document why MRI is not appropriate. In cases of back pain without red flags, six weeks of

More information

Spine MRI and Spine CT Test Request Tip Sheet

Spine MRI and Spine CT Test Request Tip Sheet Spine MRI and Spine CT With/Without Contrast CT, MRI The study considered best for a specific clinical scenario should be ordered. The second study should be done ONLY if the first study does not provide

More information

Accounting for Imaging Dose

Accounting for Imaging Dose Accounting for Imaging Dose High Profile Over-exposures Lead to Growing Concern FDA issues warning in October 2009-209 patients exposed to 8 times typical dose for CT brain perfusion scan (3-4 Gy) - Some

More information

CT Radiation Risks and Dose Reduction

CT Radiation Risks and Dose Reduction CT Radiation Risks and Dose Reduction Walter L. Robinson, M.S. D.A.B.S.N.M., D.A.B.M.P., D.A.B.R. Consultant Certified Medical Radiation Health & Diagnostic Imaging Physicist Medical Radiation and Children

More information

Chief Radiographer TEI Clinical Associate 2016

Chief Radiographer TEI Clinical Associate 2016 MDCT Principles i and Applications Ε ΑGADAKOS MSc Ε. ΑGADAKOS MSc Chief Radiographer TEI Clinical Associate 2016 Aim To understand d recent technological advances in MSCT and how they can be effectively

More information

Dianna Cody, PhD, DABR, FAAPM Professor & Clinical Operations Director Imaging Physics U.T. M.D. Anderson Cancer Center Houston, TX

Dianna Cody, PhD, DABR, FAAPM Professor & Clinical Operations Director Imaging Physics U.T. M.D. Anderson Cancer Center Houston, TX Dianna Cody, PhD, DABR, FAAPM Professor & Clinical Operations Director Imaging Physics U.T. M.D. Anderson Cancer Center Houston, TX Learning Objectives: Limitations for estimating patient dose for CT Methods

More information

Regional diagnostic reference levels and collective effective doses from CT scanners in India

Regional diagnostic reference levels and collective effective doses from CT scanners in India Regional diagnostic reference levels and collective effective doses from CT scanners in India Roshan S Livingstone and Paul M Dinakaran Department of Radiology Christian Medical College, Vellore, S India

More information

In pursuit of high value practice: Designing a strategic plan to reduce unnecessary imaging in an academic radiology department.

In pursuit of high value practice: Designing a strategic plan to reduce unnecessary imaging in an academic radiology department. In pursuit of high value practice: Designing a strategic plan to reduce unnecessary imaging in an academic radiology department April 17, 2017 1 Authors and Disclosure Matthew D. Alvin, MD, MBA, MS, MA

More information

Doses from Cervical Spine Computed Tomography (CT) examinations in the UK. John Holroyd and Sue Edyvean

Doses from Cervical Spine Computed Tomography (CT) examinations in the UK. John Holroyd and Sue Edyvean Doses from Cervical Spine Computed Tomography (CT) examinations in the UK John Holroyd and Sue Edyvean Why a new dose survey? Number of enquires received concerning the current NDRL Concern that could

More information

Calculation of Effective Doses for Radiotherapy Cone-Beam CT and Nuclear Medicine Hawkeye CT Laura Sawyer

Calculation of Effective Doses for Radiotherapy Cone-Beam CT and Nuclear Medicine Hawkeye CT Laura Sawyer Calculation of Effective Doses for Radiotherapy Cone-Beam CT and Nuclear Medicine Hawkeye CT Laura Sawyer Department of Medical Physics and Bioengineering, Royal United Hospital, Bath Overview Varian Acuity

More information

Downloaded from journal.skums.ac.ir at 11: on Tuesday August 29th * 1

Downloaded from journal.skums.ac.ir at 11: on Tuesday August 29th * 1 47-53 /1391 /4 14 / 1 * 1 2 2 1. 90/6/21 :.(4).(5) 0/6.(6) 90/5/10 : 90/1/29 : :. :. (NSAID).. 3-12 3-12 160 : 40 0/5 mg/kg 2. 24.. 0/5 mg/kg. Oucher 6. 24 : (P

More information

2013 myresearch Public Health Internship Program

2013 myresearch Public Health Internship Program 2013 myresearch Public Health Internship Program Joo Kim Public Health Internship Program Open Repair: Significance of Mesh Type on Inguinal Herniorrhaphy Joo Kim Richard T. Guttman Jr., MD, FACS Abstract

More information

Thoracic examinations with 16, 64, 128 and 256 slices CT: comparison of exposure doses measured with an anthropomorphic phantom and TLD dosimeters

Thoracic examinations with 16, 64, 128 and 256 slices CT: comparison of exposure doses measured with an anthropomorphic phantom and TLD dosimeters Thoracic examinations with 16, 64, 128 and 256 slices CT: comparison of exposure doses measured with an anthropomorphic phantom and TLD dosimeters Poster No.: C-2584 Congress: ECR 2015 Type: Scientific

More information

2014 myresearch Radiology Internship Program

2014 myresearch Radiology Internship Program 2014 myresearch Radiology Internship Program Aryah Basu Radiology Internship Program CT Guided Random Renal Biopsies: Assessing for any Differences in Biopsy Techniques and their Resulting Specimen Quality

More information

JUSTIFICATION PROTOCOLS FOR CT SCANNING ALBURY WODONGA HEALTH WODONGA CAMPUS

JUSTIFICATION PROTOCOLS FOR CT SCANNING ALBURY WODONGA HEALTH WODONGA CAMPUS JUSTIFICATION PROTOCOLS FOR CT SCANNING ALBURY WODONGA HEALTH WODONGA CAMPUS JUSTIFICATION PROTOCOLS FOR CT SCANNING INTRODUCTION: In accordance with the Victorian Radiation Act 2005 Wodonga Medical Imaging,

More information

Survey of patients CT radiation dose in Jiangsu Province

Survey of patients CT radiation dose in Jiangsu Province Original Article Page 1 of 6 Survey of patients CT radiation dose in Jiangsu Province Yuanyuan Zhou 1, Chunyong Yang 1, Xingjiang Cao 1, Xiang Du 1, Ningle Yu 1, Xianfeng Zhou 2, Baoli Zhu 1, Jin Wang

More information

SAUDI BOARD RESIDENCY TRAINING PROGRAM. OTORHINOLARYNGOLOGY HEAD AND NECK SURGERY End of Year Progress Examination 2018

SAUDI BOARD RESIDENCY TRAINING PROGRAM. OTORHINOLARYNGOLOGY HEAD AND NECK SURGERY End of Year Progress Examination 2018 SAUDI BOARD RESIDENCY TRAINING PROGRAM OTORHINOLARYNGOLOGY HEAD End of Year Progress Examination 2018 Objectives: The general objective of the annual assessment is to evaluate that the trainee has satisfactorily

More information

Pediatric CT Protocols (18 years old or less)

Pediatric CT Protocols (18 years old or less) Pediatric CT Protocols (18 years old or less) Ped1: Head CT Ped2: Cervical spine CT Ped3: Sinus CT Ped4: Neck CT Ped5: Chest CT Ped6: Abdomen and pelvis CT Ped7: Thoracic or lumbar spine CT Ped8: Extremity

More information

Fetal Dose Calculations and Impact on Patient Care

Fetal Dose Calculations and Impact on Patient Care Fetal Dose Calculations and Impact on Patient Care Matt Hough, MS, DABR, DABMP Florida Hospital Diagnostic Medical Physics and Radiation Safety Resource ACR-SPR Practice Parameter for Imaging Pregnant

More information

Computed tomography Acceptance testing and dose measurements

Computed tomography Acceptance testing and dose measurements Computed tomography Acceptance testing and dose measurements Jonas Andersson Medical Physicist, Ph.D. Department of Radiation Sciences University Hospital of Norrland, Umeå Sweden Contents The Computed

More information

A multicentric study on patient dose in multislice CT

A multicentric study on patient dose in multislice CT A multicentric study on patient dose in multislice CT A.Stratis 1, M.Molfetas 1, S.Kottou 2, A.Louizi 2 1. Medical Physics department, Evangelismos General hospital of Athens, Athens, Greece 2. Medical

More information

National Imaging Associates, Inc. Clinical guidelines/considerations SINUS & MAXILLOFACIAL AREA CT 70486, 70487, 70488

National Imaging Associates, Inc. Clinical guidelines/considerations SINUS & MAXILLOFACIAL AREA CT 70486, 70487, 70488 National Imaging Associates, Inc. Clinical guidelines/considerations SINUS & MAXILLOFACIAL AREA CT 70486, 70487, 70488 Date: September 1997 Page 1 of 5 LIMITED OR LOCALIZED FOLLOW UP - SINUS CT 76380 Guideline

More information

An audit of radiation dose of 4D CT in a radiotherapy department

An audit of radiation dose of 4D CT in a radiotherapy department An audit of radiation dose of 4D CT in a radiotherapy department Poster No.: R-0097 Congress: Type: Authors: Keywords: DOI: 2014 CSM Scientific Exhibit T. Hubbard, J. Callahan, J. Cramb, R. Budd, T. Kron;

More information

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols Personalization of Pediatric Imaging in Terms of Needed Indication-Based Quality Per Dose Acknowledgments Duke University Medical Center Ehsan Samei, PhD Donald Frush, MD Xiang Li PhD DABR Cleveland Clinic

More information

Ask EuroSafe Imaging Tips & Tricks. CT Working Group

Ask EuroSafe Imaging Tips & Tricks. CT Working Group Ask EuroSafe Imaging Tips & Tricks CT Working Group Organ Based Tube Current Modulation to Reduce Radiation Dose to Superficial Radiosensitive Organs Eileen Kelly (Galway University Hospitals, IE) Matthias

More information

3/5/2015. Don t Electrocute Me!: Common Misconceptions in Imaging and Radiation Safety (and What to Do About Them)

3/5/2015. Don t Electrocute Me!: Common Misconceptions in Imaging and Radiation Safety (and What to Do About Them) Don t Electrocute Me!: Common Misconceptions in Imaging and Radiation Safety (and What to Do About Them) Rebecca Milman Marsh, Ph.D. University of Colorado Department of Radiology Who in the Facility Works

More information

Maxillary Sinus Measurements in Different Age Groups of Human Cadavers

Maxillary Sinus Measurements in Different Age Groups of Human Cadavers Tikrit Journal for Dental Sciences 1(2013)107-112 Maxillary Sinus Measurements in Different Age Groups of Human Cadavers Mohammad A. Abd-alla BDS, MSc., Ph.D. (1) Abdul-Jabbar J. Mahdi BDS, MSc., Ph.D.

More information

SOMATOM Drive System Owner Manual Dosimetry and imaging performance report

SOMATOM Drive System Owner Manual Dosimetry and imaging performance report www.siemens.com/healthcare SOMATOM Drive System Owner Manual Dosimetry and imaging performance report Table of contents 1 Dosimetry and imaging performance report 5 1.1 Dose information 5 1.1.1 General

More information

2013 myresearch Science Internship Program

2013 myresearch Science Internship Program 2013 myresearch Science Internship Program Ryan Palko Science Internship Program Association and Frequency of Antithyroid Antibodies in Fibromyalgia Cohort at the Cleveland Clinic Ryan Palko Mehrnaz Hojjati

More information

Radiation Dosimetry for CT Protocols

Radiation Dosimetry for CT Protocols Radiation Dosimetry for CT Protocols This document contains radiation dosimetry information from CT scans and can be used by investigators to estimate the dosimetry information required by the JRSC or

More information

CT examination is a high-radiation-dose imaging technique

CT examination is a high-radiation-dose imaging technique ORIGINAL RESEARCH J.S.P. Tan K.-L. Tan J.C.L. Lee C.-M. Wan J.-L. Leong L.-L. Chan Comparison of Eye Lens Dose on Neuroimaging Protocols between 16- and 64-Section Multidetector CT: Achieving the Lowest

More information

CT Quality Control Manual FAQs

CT Quality Control Manual FAQs CT Quality Control Manual FAQs General Question: How often will the QC Manual be updated and how will those updates be communicated? Answer: The ACR CT Physics Subcommittee will review any comments, issues

More information

2013 myresearch Science Internship Program for Nursing

2013 myresearch Science Internship Program for Nursing 2013 myresearch Science Internship Program for Nursing Tamarea Townes Science Internship Program for Nursing An Investigation of Risk Factors Associated with Hypoglycemia in Adult Hospitalized Patients

More information

Methods of Counting Ribs on Chest CT: The Modified Sternomanubrial Approach 1

Methods of Counting Ribs on Chest CT: The Modified Sternomanubrial Approach 1 Methods of Counting Ribs on Chest CT: The Modified Sternomanubrial Approach 1 Kyung Sik Yi, M.D., Sung Jin Kim, M.D., Min Hee Jeon, M.D., Seung Young Lee, M.D., Il Hun Bae, M.D. Purpose: The purpose of

More information

School of Health Professions Summer 2018 Textbook List

School of Health Professions Summer 2018 Textbook List CC 4521 Prenat Cytogen Clin Rotat CC 4531 Cytgn of Hem Mal Clin Rot CL 4260 Capstone Seminar CL 4321 Clinical Microbiology CL 4332 Clinical Immunohematology CL 4530 Clinical Core Rotation DG 6100 Clinical

More information

CT Dose Reduction in Pediatric Patients

CT Dose Reduction in Pediatric Patients CT Dose Reduction in Pediatric Patients By Kelly Firestine, RT(R)(CT)(M) Executive Summary CT is an incredibly valuable imaging tool, but there are unique concerns with pediatric patients, including the

More information

Debra Pennington, MD Director of Imaging Dell Children s Medical Center

Debra Pennington, MD Director of Imaging Dell Children s Medical Center Debra Pennington, MD Director of Imaging Dell Children s Medical Center 1 Gray (Gy) is 1 J of radiation energy/ 1 kg matter (physical quantity absorbed dose) Diagnostic imaging doses in mgy (.001 Gy)

More information

Re: PSM of the National Voluntary Consensus Standard for Patient Safety Measures, 2 nd Report

Re: PSM of the National Voluntary Consensus Standard for Patient Safety Measures, 2 nd Report Re: PSM-044-10 of the National Voluntary Consensus Standard for Patient Safety Measures, 2 nd Report Dear members of the National Quality Forum Board: As Professors of Radiologic Physics (at Mayo Clinic

More information

What is head and neck cancer? How is head and neck cancer diagnosed and evaluated? How is head and neck cancer treated?

What is head and neck cancer? How is head and neck cancer diagnosed and evaluated? How is head and neck cancer treated? Scan for mobile link. Head and Neck Cancer Head and neck cancer is a group of cancers that start in the oral cavity, larynx, pharynx, salivary glands, nasal cavity or paranasal sinuses. They usually begin

More information

A clinical study on branchial arch anomalies

A clinical study on branchial arch anomalies IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861.Volume 18, Issue 1 Ver. 5 (January. 2019), PP 05-10 www.iosrjournals.org Ashim Sarkar 1, Ritam Ray 2 1 (Clinical

More information

ADI Procedure Codes. August 2016 Revised April 2017 Page 1 of 7 ADI Procedure Codes

ADI Procedure Codes. August 2016 Revised April 2017 Page 1 of 7 ADI Procedure Codes Code Description 70450 CT Head without contrast 70460 CT Head with contrast 70470 CT Head with & without contrast 70480 CT Orbit, et al without contrast 70481 CT Orbit, et al with contrast 70482 CT Orbit,

More information

Pushing the limits of cardiac CT. Steven Dymarkowski Radiology / Medical Imaging Research Centre

Pushing the limits of cardiac CT. Steven Dymarkowski Radiology / Medical Imaging Research Centre Pushing the limits of cardiac CT Steven Dymarkowski Radiology / Medical Imaging Research Centre 5 X 2013 Introduction Rapid technological advances and new clinical applications in cardiovascular imaging

More information

Introduction and Background

Introduction and Background CT Lung Cancer Screening and the Medical Physicist: Background, Findings and Participant Dosimetry Summary of the National Lung Screening Trial (NLST) Randell Kruger, PhD, DABR Medical Physics Section

More information

8/1/2017. Financial Disclosures. Dose Tracking at MGH. How Dose Tracking Affected Protocol Optimization in a Tertiary Quaternary Healthcare Center

8/1/2017. Financial Disclosures. Dose Tracking at MGH. How Dose Tracking Affected Protocol Optimization in a Tertiary Quaternary Healthcare Center How Dose Tracking Affected Protocol Optimization in a Tertiary Quaternary Healthcare Center Mannudeep K. Kalra, MD Webster Center for Quality and Safety Massachusetts General Hospital Harvard Medical School

More information

X-Ray & CT Physics / Clinical CT

X-Ray & CT Physics / Clinical CT Computed Tomography-Basic Principles and Good Practice X-Ray & CT Physics / Clinical CT INSTRUCTORS: Dane Franklin, MBA, RT (R) (CT) Office hours will be Tuesdays from 5pm to 6pm CLASSROOM: TIME: REQUIRED

More information

Study of correlation between patient symptomatology and incidental paranasal sinus abnormalities detected on CT & MRI Brain imaging

Study of correlation between patient symptomatology and incidental paranasal sinus abnormalities detected on CT & MRI Brain imaging Original article Study of correlation between patient symptomatology and incidental paranasal sinus abnormalities detected on CT & MRI Brain imaging 1 DR. SHAIKH IMRAN NIZAMUDDIN, 2 DR. Y.P.SACHDEV*, 3

More information

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method Iran. J. Radiat. Res., 2004; 1(4): 187-194 Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method M.R. Ay 1, M. Shahriari 2, S. Sarkar 3, P.

More information

8/18/2011. Acknowledgements. Managing Pediatric CT Patient Doses INTRODUCTION

8/18/2011. Acknowledgements. Managing Pediatric CT Patient Doses INTRODUCTION Managing Pediatric CT Patient Doses Keith J. Strauss, MSc, FAAPM, FACR President X-Ray Computations, Inc. Boston, Massachusetts Acknowledgements Marilyn Goske, MD John Boone, PhD Cynthia McCollough, PhD

More information

Radiation Dose To Pediatric Patients in Computed Tomography in Sudan

Radiation Dose To Pediatric Patients in Computed Tomography in Sudan Radiation Dose To Pediatric Patients in Computed Tomography in Sudan Omer Osman,Saeed Medical Physics Department, ALNeelain University, Sudan Presentation outlines Introduction Objectives Materials and

More information

Planmeca Ultra Low Dose

Planmeca Ultra Low Dose OWN THE FUTURE Practice Ultra Low Dose 3D imaging with lower dose than panoramic imaging Ultra Low Dose Pioneering low dose 3D imaging 3D units offer a unique Ultra Low Dose imaging protocol that enables

More information

Machine Learning Powered Automatic Organ Classification for Patient Specific Organ Dose Estimation

Machine Learning Powered Automatic Organ Classification for Patient Specific Organ Dose Estimation Machine Learning Powered Automatic Organ Classification for Patient Specific Organ Dose Estimation Junghwan Cho, Eunmi Lee, Hyunkwang Lee, Bob Liu, Xinhua Li, Shahein Tajmir, Dushyant Sahani, and Synho

More information

2018 OPTIONS FOR INDIVIDUAL MEASURES: REGISTRY ONLY. MEASURE TYPE: Efficiency

2018 OPTIONS FOR INDIVIDUAL MEASURES: REGISTRY ONLY. MEASURE TYPE: Efficiency Quality ID #333: Adult Sinusitis: Computerized Tomography (CT) for Acute Sinusitis (Overuse) National Quality Strategy Domain: Efficiency and Cost Reduction 2018 OPTIONS FOR INDIVIDUAL MEASURES: REGISTRY

More information

Head and Neck Cancer. What is head and neck cancer?

Head and Neck Cancer. What is head and neck cancer? Scan for mobile link. Head and Neck Cancer Head and neck cancer is a group of cancers that usually originate in the squamous cells that line the mouth, nose and throat. Typical symptoms include a persistent

More information

Ask EuroSafe Imaging. Tips & Tricks. CT Working Group. Optimization of scan length to reduce CT radiation dose

Ask EuroSafe Imaging. Tips & Tricks. CT Working Group. Optimization of scan length to reduce CT radiation dose Ask EuroSafe Imaging Tips & Tricks CT Working Group Optimization of scan length to reduce CT radiation dose Alban Gervaise (Centre Hospitalier Universitaire Nancy, FR) Mika Kortesniemi (HUS Medical Imaging

More information

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine ESTABLISHING DRLs in PEDIATRIC CT Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine CT Dose Indices CTDI INTRODUCTION CTDI 100, CTDI w, CTDI vol

More information

Technology Assessment Institute: Summit on CT Dose Cardiac CT - Optimal Use of Evolving Scanner Technologies

Technology Assessment Institute: Summit on CT Dose Cardiac CT - Optimal Use of Evolving Scanner Technologies Cardiac CT - Optimal Use of Evolving Scanner Technologies P. Rogalla, M.D. Dept. of Medical Imaging University of Toronto Special thanks to Dr. Lembcke, Dr. Hein Charité, Berlin Disclosures No salaries

More information

Radiation Dose Reduction Strategies in Coronary CT Angiography

Radiation Dose Reduction Strategies in Coronary CT Angiography Radiation Dose Reduction Strategies in Coronary CT Angiography Noor Diyana Osman, PhD noordiyana@usm.my Contents: Introduction Radiation dosimetry in CT Radiation risk associated with coronary CT angiography

More information

An Update of VirtualDose Software Used for Assessing Patient Organ Doses from CT Examinations

An Update of VirtualDose Software Used for Assessing Patient Organ Doses from CT Examinations An Update of VirtualDose Software Used for Assessing Patient Organ Doses from CT Examinations Aiping Ding, X. George Xu Rensselaer Polytechnic Institute Troy, NY USA http://rrmdg.rpi.edu 1 Acknowledgements

More information

Managing Patient Dose in Computed Tomography (CT) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION

Managing Patient Dose in Computed Tomography (CT) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION Managing Patient Dose in Computed Tomography (CT) International Commission on Radiological Protection Information abstracted from ICRP Publication 87 Available at www.icrp.org Task Group: M.M. Rehani,

More information

Implementation & optimization of a lung cancer screening CT program. Presented by Izabella Barreto at the 2016 Florida AAPM Chapter Meeting

Implementation & optimization of a lung cancer screening CT program. Presented by Izabella Barreto at the 2016 Florida AAPM Chapter Meeting Implementation & optimization of a lung cancer screening CT program Presented by Izabella Barreto at the 2016 Florida AAPM Chapter Meeting Izabella Barreto, Nathan Quails, Catherine Carranza, Nathalie

More information

, David Stultz, MD. Cardiac CT. David Stultz, MD Cardiology Fellow, PGY 6 March 28, 2006

, David Stultz, MD. Cardiac CT. David Stultz, MD Cardiology Fellow, PGY 6 March 28, 2006 Cardiac CT David Stultz, MD Cardiology Fellow, PGY 6 March 28, 2006 Courtesy Tom Kracus Courtesy Kettering Tom Medical Kracus Cente Kettering Medical Center 2003-2006, David Stultz, MD Courtesy Tom Kracus

More information

True Dual Energy. Dr. Stefan Ulzheimer, Siemens Healthcare GmbH. DEfinitely Siemens

True Dual Energy. Dr. Stefan Ulzheimer, Siemens Healthcare GmbH. DEfinitely Siemens DEfinitely Siemens True Dual Energy Dr. Stefan Ulzheimer, Siemens Healthcare GmbH International version. Not for distribution in the US. Unrestricted Siemens AG 2015 All rights reserved. The products/features

More information

Ask EuroSafe Imaging Tips & Tricks. CT Working Group. On the use of Diagnostic Reference Levels in CT

Ask EuroSafe Imaging Tips & Tricks. CT Working Group. On the use of Diagnostic Reference Levels in CT Ask EuroSafe Imaging Tips & Tricks CT Working Group On the use of Diagnostic Reference Levels in CT Robert Bujila (Karolinska University Hospital, SE) Eileen Kelly (Galway University Hospitals, IE) Matthias

More information

ORIGINAL ARTICLE. Ighodaro O. Emmanuel, Ehigiamusoe O. Festus

ORIGINAL ARTICLE. Ighodaro O. Emmanuel, Ehigiamusoe O. Festus ORIGINAL ARTICLE Lund-Mackay Scoring of Incidental Paranasal Sinus Collection on Computed Tomography Scan of Head and Neck in the University of Benin Teaching Hospital, Nigeria Ighodaro O. Emmanuel, Ehigiamusoe

More information

Image Diagnostic Technology Ltd IDT Ireland, 15 Market Street, Kinsale, Co. Cork, Ireland P17 XN65 Tel: Mob: IRL:

Image Diagnostic Technology Ltd IDT Ireland, 15 Market Street, Kinsale, Co. Cork, Ireland P17 XN65 Tel: Mob: IRL: Image Diagnostic Technology Ltd IDT Ireland, 15 Market Street, Kinsale, Co. Cork, Ireland P17 XN65 Tel: +44 20 8819 9158 Mob: +44 7767 366596 IRL: +353 21 470 9501 Web: www.simplantscans.com Email: info@ctscan.co.uk

More information

Low Dose Era in Cardiac CT

Low Dose Era in Cardiac CT Low Dose Era in Cardiac CT DIANA E. LITMANOVICH, MD Department of Radiology Beth Israel Deaconess Medical Center Harvard Medical School Disclosures Neither I nor my immediate family members have a financial

More information

2014 myresearch SCIENCE Internship Program

2014 myresearch SCIENCE Internship Program 2014 myresearch SCIENCE Internship Program Maya Gaines-Smith Science Internship Program Does Mobilization of Patients With a Cancer Diagnosis Decrease Pain? Maya Gaines-Smith Marianne Douglas, MS CCC/SLP

More information

Estimating Patient Radiation Dose from Computed Tomography

Estimating Patient Radiation Dose from Computed Tomography Estimating Patient Radiation Dose from Computed Tomography C. Cagnon, J. DeMarco, E. Angel, M. McNitt-Gray UCLA David Geffen School of Medicine 1 Patient Dose from CT Advances in Technology... Helical

More information

JMSCR Vol 06 Issue 12 Page December 2018

JMSCR Vol 06 Issue 12 Page December 2018 www.jmscr.igmpublication.org Impact Factor (SJIF): 6.379 Index Copernicus Value: 79.54 ISSN (e)-2347-176x ISSN (p) 2455-0450 DOI: https://dx.doi.org/10.18535/jmscr/v6i12.80 Diagnostic Reference Levels:

More information

Conventional and spiral CT dose indices in Yazd general hospitals, Iran

Conventional and spiral CT dose indices in Yazd general hospitals, Iran Iran. J. Radiat. Res., 2006; 3 (4): 183-189 Conventional and spiral CT dose indices in Yazd general hospitals, Iran F. Bouzarjomehri 1*,M.H.Zare 2, D. Shahbazi 2 1 Department of Medical Physics, Shahid

More information

Quality Control and Patient Dosimetry on line for Computed Tomography

Quality Control and Patient Dosimetry on line for Computed Tomography Quality Control and Patient Dosimetry on line for Computed Tomography Jose I. Ten 1,2, Eliseo Vano 2,3, Jose M. Fernandez-Soto 2,3, Roberto Sanchez 3, Juan Arrazola 1,2 1 Diagnostic Radiology Service and

More information

The Choosing Wisely Project. Disclosures. Learning Objectives 3/18/2014. Marie Gilbert, PA C, DFAAPA

The Choosing Wisely Project. Disclosures. Learning Objectives 3/18/2014. Marie Gilbert, PA C, DFAAPA The Choosing Wisely Project Marie Gilbert, PA C, DFAAPA Disclosures This speaker has no commercial relationships to disclose. Learning Objectives List the five "Choosing Wisely" program items for Otolaryngology.

More information

AIM 2014 CPT Radiology & Cardiac Codes Requiring Review

AIM 2014 CPT Radiology & Cardiac Codes Requiring Review AIM 2014 CPT Radiology & Cardiac Codes Requiring Review Modality Body Part CT Head 1 70480 CT orbit, sella or posterior fossa; w/o contrast 1 CT Head 1 70481 CT orbit, sella or posterior fossa; with CT

More information

Value of Multidisciplinary Lecture Series in Appropriate Use of Imaging Studies

Value of Multidisciplinary Lecture Series in Appropriate Use of Imaging Studies Value of Multidisciplinary Lecture Series in Appropriate Use of Imaging Studies Authors: Nathan Kolderman, James Davis, Alexander Copelan, Mina Zaki, Paul Thottakara, Farnoosh Sokhandon The authors have

More information

Patient Dose Estimates. from CT Examinations. Patient Dose Estimates

Patient Dose Estimates. from CT Examinations. Patient Dose Estimates Patient Dose Estimates from CT Examinations Patient Dose Estimates from CT Examinations John M. Boone, Ph.D. Professor and Vice Chairman of Radiology Professor of Biomedical Engineering University of California,

More information

Managing Patient Dose in Computed Tomography (CT)

Managing Patient Dose in Computed Tomography (CT) Managing Patient Dose in Computed Tomography (CT) International Commission on Radiological Protection Information abstracted from ICRP Publication 87 Available at www.icrp.org Task Group: M.M. Rehani,

More information

International Journal of Health Sciences and Research ISSN:

International Journal of Health Sciences and Research  ISSN: International Journal of Health Sciences and Research www.ijhsr.org ISSN: 2249-9571 Original Research Article Anatomical Study of the Middle Meatus with Emphasis to the Maxillary Ostium and Their Clinical

More information

The diagnostic value of Computed Tomography in evaluation of maxillofacial Trauma

The diagnostic value of Computed Tomography in evaluation of maxillofacial Trauma The diagnostic value of Computed Tomography in evaluation of maxillofacial Trauma Qais H. Muassa FICMS College of Dentistry, Babylon University Ibrahim S. Gataa, BDS, FICMS College of Dentistry, Sulaimania

More information