1 NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE GUIDANCE EXECUTIVE (GE) Review of TA167; Endovascular stent-grafts for abdominal aortic aneurysms Final recommendation post consultation The guidance should be updated in an on-going clinical guideline. 1. Background This guidance was issued in February At the GE meeting of 18 August 2015 it was agreed that we would consult on the recommendations made in the GE proposal paper. A four week consultation has been conducted with consultees and commentators and the responses are presented below. 2. Proposal put to consultees and commentators The guidance should be updated in an on-going clinical guideline. 3. Rationale for selecting this proposal No new evidence has emerged that is expected to substantially change the recommendation in section 1.1. More experience with endovascular aortic stent grafts is now available which means that recommendations 1.2 and 1.3 could be further developed. More evidence has emerged that is relevant to recommendation 1.4. In order to develop up to date and consistent guidance, we propose that all recommendations are updated in the forthcoming clinical guideline on the diagnosis and management of abdominal aortic aneurysms. 4. Summary of consultee and commentator responses Page 1 of 13

2 Comments received in the course of consultations carried out by NICE are published in the interests of openness and transparency, and to promote understanding of how recommendations are developed. The comments are published as a record of the submissions that NICE has received, and are not endorsed by NICE, its officers or advisory committees. Respondent: Medtronic Response to proposal: Agree (with caveat) Medtronic support the proposal to supersede and update the TA167 recommendations into the forthcoming clinical guideline. However we wish it to be noted that we do have concerns that the removal of the mandated TA may impact patient access and politely request that audit measures or quality standards are concurrently developed to ensure patient access is not unduly impacted and objective measures are in place to monitor this access and unmet need. Medtronic look forward to offering input into the new guidelines and providing supporting clinical evidence related to Medtronic technologies where appropriate. Comment from Technology Appraisals Comment noted. NICE ensures that implementation issues are analysed and considered as an integral part of guideline development. NICE provides additional support for some guideline topics informed by priorities identified in the quality standards library and the selection of improvement areas within the quality standard development process. Respondent: Royal College of Surgeons Response to proposal: No comment We have passed this on to the Vascular Society. Comment from Technology Appraisals No action required Respondent: Royal College of Nursing Response to proposal: No comment Comment from Technology Appraisals No action required Page 2 of 13

3 Respondent: Endologix Response to proposal: We agree with the proposal to update the guidance based on the availability of new information relevant to the treatment of ruptured infrarenal abdominal aortic aneurysms. We agree with the statement made in section 7 regarding endovascular stent grafts for un-ruptured infra-renal aneurysm: there is no data to suggest that different brands of endovascular stent grafts should be considered separately. Further in section 7, several new brands that have been CE Marked since TA167 was first issued are identified, including Anaconda, Endurant, Ovation, InCraft, and Aptus. Two brands are excluded, and we request that these be added: o AFX Endovascular AAA System, CE Marked in 2011 o We note that the LEOPARD randomized trial was included in the list of registered clinical trials (page 11). o Nellix EndoVascular Aneurysm Sealing System, CE Marked in o We note that the Nellix registered clinical studies (NCT and NCT ) are not shown in the list of registered clinical trials (page 11); we request these are added. o In addition, peer-review publications (excluding case reports) are available for reference: 1. Böckler D, Holden A, Thompson M, et al. Multicenter Nellix EndoVascular Aneurysm Sealing system experience in aneurysm sac sealing. J Vasc Surg 2015; 62: Brownrigg JRW, de Bruin JL, Rossi L, et al. Endovascular aneurysm sealing for infrarenal abdominal aortic aneurysms: 30-day outcomes of 105 patients in a single centre. Eur J Vasc Endovasc Surg 2015:50; Carpenter JP, Cuff RF, Böckler D, et al. Thirty-day results of the pivotal trial of the Nellix System for endovascular aneurysm sealing (EVAS). J Vasc Surg 2015;61:8S (abstract). Accepted for publication. 4. D Abate F, Harrison SA, Karthikesalingam A, et al. Sonographic appearance following endovascular aneurysm repair using the Nellix endovascular sealing system. J Endovasc Ther 2015;22(2): Commentary: Holden A and Reijnen MP. J Endovasc Ther 2015; 22: Ezite N, Savlovskis J, Gedins M, et al. Duplex ultrasound versus computed tomography for follow-up of complications after EVAR with Nellix endograft: first clinical experience. Acta Chir Lat 2013;13: Hill A. Nellix EVAS: Early Results From the Forward Registry and Beyond. J Vasc Surg 2015;62: Holden A. Endovascular sac sealing concept: will the Endologix Nellix device solve the deficiencies? J Comment from Technology Appraisals Comments noted. NICE acknowledges that the 2 brands highlighted by Endologix were omitted from the table of new brands that have become available since TA167 in the review proposal paper (AFX Endovascular AAA System and Nellix EndoVascular Aneurysm Sealing System). It should be noted that the AFX Endovascular AAA System is described on page 10 of the review proposal paper. NICE also acknowledges that the Nellix registered clinical studies (NCT and NCT ) were omitted from the list of registered clinical trials (page 11). Thank you for bringing these to our attention. NICE considers that, in the absence of additional further evidence for clinical or cost effectiveness, the additional products and registered trials noted by Endologix would not have changed the recommendations of the review proposal paper to update the guidance in an on-going clinical guideline. The processes of the technology appraisals programme do not allow for combining with assessments in the interventional procedures programme. Consideration of efficacy and safety in the interventional Page 3 of 13

4 Cardiovasc Surg 2015;56: Karthikesalingam A, Cobb RJ, Khoury A, et al. The morphological applicability of a novel endovascular aneurysm sealing (EVAS) system (Nellix) in patients with abdominal aortic aneurysms. Eur J Vasc Endovasc Surg 2013;46(4): Commentary: Tshomba Y and Chiesa R. Commentary: Eur J Vasc Endovasc Surg 2013;46(4): Karthikesalingham A, de Bruin JL, Patel SR, et al. Appearance of the Nellix Endovascular Aneurysm Sealing System on computed tomography: implications for postoperative imaging surveillance. J Endovasc Ther 2015;22(3): Commentary: Holden A, Reijnen MP. J Endovasc Ther 2015; 22: McWilliams RG, Fisher RK, England A, and Torella F. Observations on surveillance imaging after endovascular sealing of abdominal aortic aneurysms with the Nellix System. J Endovasc Ther 2015; 22: Commentary: Holden A and Reijnen MP. J Endovasc Ther 2015; 22: Savlovskis J, Krievins D, de Vries JP, et al. Aortic neck enlargement after endovascular aneurysm repair using balloon-expandable versus self-expanding endografts. J Vasc Surg 2015 (e-published). 12. van den Ham LH, Zeebregts CJ, de Vries JP, and Reijnen MM. Abdominal aortic aneurysm repair using Nellix EndoVascular Aneurysm Sealing. Surg Technol Int 2015;26: In Appendix 1, the fourth option is stated as A review of the guidance should be combined with a new technology appraisal that has recently been referred to NICE. The review will be conducted through the MTA process. This option was not selected. We believe the in process assessment for endovascular aneurysm sealing (IP1283) should be combined with TA167, because IP1283 currently only includes the CE Marked Nellix EndoVascular Aneurysm Sealing System. The Nellix EndoVascular Aneurysm Sealing (EVAS) System is among a class of CE Marked medical devices intended for the endovascular repair of abdominal aortic aneurysm (AAA). Its intended patient population and mode of action in providing an endovascular conduit to prevent aneurysm rupture in appropriately selected patients is consistent with other endovascular repair devices included or proposed for inclusion under TA167. Note that Endologix completed patient enrollment in the Nellix US Investigational Device Exemption (IDE) pivotal trial and in the Global Post-market Registry in Both studies are registered under (NCT and NCT , respectively). o The primary safety endpoint results from the Nellix IDE Study are reported in a procedures programme occurs before a Technology Appraisal Programme can address the clinical and cost effectiveness. NICE has considered the availability of the additional highlighted products (including the Nellix EVAS System), and as noted above, we consider the recommendations of the review proposal paper to update the guidance in an on-going clinical guideline should still stand. The appropriateness of including the Nellix EVAS System in the ongoing clinical guideline will be considered separately within that programme. Page 4 of 13

5 manuscript accepted for publication in the Journal of Vascular Surgery see Appendix A at the end of this paper. o Presented results from the Nellix Global Registry are summarized in comparison to the published results from the ENGAGE and GREAT Registries (see Appendix). Note that the 1-year results of the Registry are intended for publication (manuscript in preparation). To illustrate the appropriateness for inclusion of the Nellix System in TA167 and the ongoing guideline, please see a comparative summary of the Indications for Use for the Nellix EVAS System and two other devices for which post-market registry data are available (Medtronic Endurant, ENGAGE Registry; Gore Excluder, GREAT Registry) below: Anatomical Dimension Nellix Indication Endurant Indication Excluder Indication Access vessel diameter Compatible with 17Fr outer profile Compatible with 18 to 20Fr outer profile Compatible with 18Fr introducer (inner profile) Infrarenal neck diameter 18 to 32mm 19 to 32mm 19 to 32mm Infrarenal neck length and angulation to the aneurysm sac 10mm with 60 (without significant calcium or thrombus) 10mm with 60 (without significant calcium or thrombus) 15mm with 75 (without significant calcium or thrombus) Suprarenal neck angulation (10mm neck length) 60 (15mm neck length) Common iliac artery diameter 9 to 35mm (lumen diameter) 8 to 25mm (vessel diameter) 15mm with 60 (without significant calcium or thrombus) to 25mm (vessel diameter) The Nellix EVAS System received marketing authorization in Europe in February 2013 based upon the 1-year results of a multicenter single arm clinical study with continuing post-market follow-up. Since that time, more than 3,000 patients have received the Nellix device in Europe and abroad. Likewise, all EVAR devices have received European marketing authorization based upon an initial single arm clinical study of Page 5 of 13

6 similar design and size with continuing follow-up. It is therefore appropriate to include the Nellix System in TA167 and the on-going guidance for endovascular repair of abdominal aortic aneurysm. Paper signed off by: Elisabeth George, 10 December 2015 Contributors to this paper: Technical Lead: Project Manager: Chris Chesters Andrew Kenyon Page 6 of 13

7 % Pts with Reintervention Appendix A additional evidence from Endologix In a published assessment, it has been reported that post-evar secondary intervention rates increase with time and with more hostile neck anatomy as encountered in clinical practice: 1 Secondary Intervention Rates Over Time: Favorable and Hostile Neck Anatomy 25 Favorable Anatomy Hostile Anatomy 20 20% 15 15% 12% % 5% 7% 6% 9% 8% 10% 10% 2.8% 0 1Mo 1Yr 2Yrs 3Yrs 4Yrs 5Yrs Among published 5-year reports of the European EVAR randomized trials and large observational studies of relatively unselected patients, secondary intervention rates of 13% to 26% are reported. This fairly consistent profile suggests that post-evar secondary intervention remains a considerable concern. 1 Stather PW, Sayers RD, Cheah A, et al. Outcomes in endovascular aneurysm repair in patients with hostile neck anatomy. Eur J Vasc Endovasc Surg 2012;44: Page 7 of 13

8 It is important to recognize that EVAR stent graft devices typically leave the aneurysm sac intact and therefore remain prone to type II endoleak from collateral vessels. In their long-term follow-up of EVAR patients, researchers in France determined that the presence of type II endoleak doubled the reintervention rate and led to sac expansion in 40% of patients as illustrated below. 2 Although endovascular intervention is routinely performed for type II endoleak with sac expansion, it does not appear to alter the rate of sac growth, and the majority of patients display persistent/recurrent endoleak. 3 This clinical problem of secondary interventions due to endoleaks of all kinds also translates to a significant economic problem for the healthcare system. 4 In a 5-year follow-up of post-placement costs, Noll and colleagues identified nearly a 5-fold increase in costs to the healthcare system when an endoleak is present post-evar. To address the continued unmet clinical need, the Nellix EVAS System was designed to seal the aneurysm sac from all forms of endoleak. When placed properly, the Polymer-filled Endobags consume the blood lumen space from the 2 El Batti S, Cochennec, F, Roudot-Thoraval F, Becquemin JP. Type II Endoleaks after endovascular repair of abdominal aortic aneurysm are not always a benign condition. J Vasc Surg 2013;57: Aziz A, Menias CO, Sanchez LA, et. al. Outcomes of percutaneous endovascular intervention for Type II endoleak with aneurysm expansion. J Vasc Surg 2012;55: Noll RE, Tonnessen BH, Mannava K, et al. Long-term postplacement cost after endovascular aneurysm repair. J Vasc Surg 2007;46:9-15. Page 8 of 13

9 infrarenal segment to the distal common iliac arteries, thereby minimizing the potential for failure modes leading to endoleak, including migration or lateral movement. CE Mark approval for the Nellix EVAS System was granted in February Following site selection, qualification, and ethics committee approvals, the EVAS Global Post-market Registry was initiated, enrolling 300 unselected (i.e., referred commonly to as real world ) patients at 18 sites in Europe and New Zealand. The 300-patient enrollment chart and top-level site enrollment information by country is shown below. Germany (5 sites): N=43 Latvia (1 site): N=10 Luxembourg (1 site): N=9 Netherlands (5 sites): N=90 New Zealand (1 site): N=38 Norway (1 site): N=5 UK (2 sites): N=98 Sweden (2 sites): N=7 After enrollment, patients are to be followed per the institutional standard of care at 30 days, 6 months, 1 year, and annually thereafter through 5 years. A Core Lab evaluates CT scans for evidence of endoleak of any type, stent fracture, migration, occlusion, or other device integrity issue. Adverse events are adjudicated by an independent assessor for analysis. Procedural outcomes and follow-up results to one year were presented at the 2015 Charing Cross (London, UK) meeting by Principal Investigator Matt Thompson, MD (St. George s Institute, London, UK). A broad array of aneurysm anatomies were treated, including those generally within the approved indications for use (Cohort 1, 64%), and those outside of the indications for use: Cohort 2 (short neck or highly angulated anatomies, 13%), Cohort 3 (juxtarenal/pararenal aneurysms, 12%), and Cohort 4 (failed EVAR repair; ruptured AAA repair; paraanastamotic aneurysm repair, 8.3%). For benchmarking purposes, the characteristics of patients enrolled with challenging anatomies in the Nellix EVAS Registry are compared to those in published post- Page 9 of 13

10 market registry studies (Endurant ENGAGE and Excluder GREAT Registries). 5,6 These are reasonable comparators because the Nellix, Endurant, and Excluder intended uses are all for the endovascular repair of AAA, and the indicated patient populations and mode of action to prevent aneurysm rupture are similar. This comparison suggests the Nellix Registry has a higher prevalence of patient anatomies treated that are outside of the approved IFU than the comparator Registries. The increasing anatomical challenge among Cohorts 1 to 3 in the Nellix Registry is further reflected in the baseline aneurysm characteristics, summarized below. Key procedural characteristics among Cohorts 1 to 3 are shown below. The overall data suggest predictable and favorable fluoroscopy and procedure times. As would be expected, the more complex repairs in Cohort 3 required more time. One 5 Stokmans RA, Teijink JA, Forbes TL, et al. Early results from the ENGAGE registry: real-world performance of the Endurant Stent Graft for endovascular AAA repair in 1262 patients. Eur J Vasc Endovasc Surg 2012;44: Verhoeven ELG, Katsargyris A, Bachoo P, et al. Real-world performance of the new C3 Gore Excluder stent graft: 1-year results from the European C3 module of the global registry for endovascular aortic treatment (GREAT). Eur J Vasc Endovasc Surg 2014;48: Cohort 4 is not included due to the severe departure in device use in treating ruptures and failed EVAR/surgical implants. Page 10 of 13

11 procedural conversion to open repair occurred in Cohort 3 (catheter retraction issue), resulting in a procedural technical success rate of 99.7%. This success rate is similar to that in ENGAGE (98.6%) and GREAT (99%). The incidence of protocol-defined major adverse events (MAEs) within 30 days and in follow-up >30 days to 1 year are show below. Three perioperative deaths were related to co-morbidities in this elderly patient population and were determined by the independent assessor to be not device-related. By way of comparison, the ENGAGE 30-day MAE rate is reported similarly as 3.9%. GREAT does not report events using a similar categorization. Despite the prevalence of high-risk enrolled patients, Nellix Registry patient follow-up to 1 year identifies Kaplan-Meier estimated freedom from all-cause mortality of 96%. This compares favorably with the corresponding results from the GREAT Registry (96%) and the ENGAGE Registry (92%). The Nellix freedom from aneurysm-related mortality at 1 year is 99%, similar to the comparator reported results (ENGAGE, 98.8%). Page 11 of 13

12 Core Lab assessment of 30-day CT scans identified no stent fracture or occlusion. Two patients (0.7%) were identified with type IA endoleak, both of which were attributed to procedural malplacement. No type II endoleak was observed. This total endoleak profile among a broad array of patient anatomies treated compares favorably with the rate for the reporting comparator (ENGAGE, 12% [1.5% type I or III, 11% type 2). The incidence of type I or III endoleak, occlusion, or implant compression/kinking/twisting at 30 days in the Nellix Registry and each comparator are shown in the table below, confirming the relative acceptability of the Nellix results. Core Lab Finding at 30 Days Nellix Registry [(n (%)] Comparison 1 (ENGAGE) Comparison 2 (GREAT) Occlusion/Stenosis 0 2.0%/1.4% 1.3% Endoleak Type I or III 2 (0.7%) 1.5% 1.0% Stent Graft Compression/Kinking/Twisting 0 1.7% 0.5% TOTAL 0.7% 3.2% 2.8% Endoleak: type 1=attachment point; 3=junctional separation or fabric hole/tear. Core Lab assessment at 1 year identified two Nellix patients (0.7%) with type IA endoleak, both of which were attributed to procedural malplacement in off-label anatomies. No type II endoleak was observed. A comparison to the outcomes among multiple devices (Cook Zenith, Medtronic Endurant, Lombard Aorfix, Gore Excluder, Cordis Incraft, and Trivascular Ovation) in selected patients enrolled in either US IDE or CE studies demonstrates a positive profile consistent with the 1- month outcomes: As illustrated below, the Nellix Registry 1-year freedom from secondary intervention for occlusion and endoleak is 99% and 96%, respectively. The overall freedom from any endovascular or surgical secondary intervention is 93%, consistent with the ENGAGE and GREAT Registry reported overall freedom from secondary intervention at 1 year (95%). It is noted that differing definitions for secondary intervention is used in the comparator reports. Page 12 of 13

13 These results in the Nellix EVAS System Registry are consistent with the comparator results, with low rates of endoleak and reintervention observed despite treating a broad range of patient anatomies. Page 13 of 13

Nellix Endovascular System: Clinical Outcomes and Device Overview

Nellix Endovascular System: Clinical Outcomes and Device Overview Nellix Endovascular System: Clinical Outcomes and Device Overview Jeffrey P. Carpenter, MD Professor and Chief, Department of Surgery CAUTION: Investigational device. This product is under clinical investigation

More information

Treatment options of late failures of EVAS. Michel Reijnen Rijnstate Arnhem The Netherlands

Treatment options of late failures of EVAS. Michel Reijnen Rijnstate Arnhem The Netherlands Treatment options of late failures of EVAS Michel Reijnen Rijnstate Arnhem The Netherlands Disclosure Speaker name: Michel Reijnen I have the following potential conflicts of interest to report: Consulting

More information

EndoVascular Aneurysm Sealing (EVAS) with Nellix

EndoVascular Aneurysm Sealing (EVAS) with Nellix 1 2 EndoVascular Aneurysm Sealing (EVAS) with Nellix Designed to seal entire aneurysm with contained biostable polymer Non-modular design with complete fixation Expands endovascular patient eligibility

More information

The Auckland Experience with the Nellix EVAS System. Andrew Holden, MBChB, FRANZCR

The Auckland Experience with the Nellix EVAS System. Andrew Holden, MBChB, FRANZCR The Auckland Experience with the Nellix EVAS System Andrew Holden, MBChB, FRANZCR Disclosure Speaker name: Associate Professor Andrew Holden I have the following potential conflicts of interest to report:

More information

Influence of patient selection and IFU compliance on outcomes following EVAS

Influence of patient selection and IFU compliance on outcomes following EVAS Influence of patient selection and IFU compliance on outcomes following EVAS LUNCH SYMPOSIUM LINC 2017 Jan MM Heyligers, MD, PhD, FEBVS Consultant Vascular Surgeon Elisabeth TweeSteden Hospital Tilburg,

More information

The Ventana Off-the-Shelf Graft for Pararenal AAA. Andrew Holden Associate Professor of Radiology Auckland Hospital

The Ventana Off-the-Shelf Graft for Pararenal AAA. Andrew Holden Associate Professor of Radiology Auckland Hospital The Ventana Off-the-Shelf Graft for Pararenal AAA Andrew Holden Associate Professor of Radiology Auckland Hospital Disclosures Andrew Holden, MBChB, FRANZCR Investigator in Nellix and Ventana Trials Clinical

More information

EVAS using Nellix in my practice Where are we today?

EVAS using Nellix in my practice Where are we today? EVAS using Nellix in my practice Where are we today? Prof. dr. Michel MPJ Reijnen Department of Vascular Surgery, Rijnstate Hospital Arnhem Faculty of Science and Technology, University of Twente The Netherlands

More information

NASDAQ: ELGX December Innovation that Empowers

NASDAQ: ELGX  December Innovation that Empowers NASDAQ: ELGX www.endologix.com December 2014 Innovation that Empowers Safe Harbor This presentation contains forward-looking statements within the meaning of the Private Securities Litigation Reform Act

More information

Important Update to Field Safety Notice Nellix EndoVascular Aneurysm Sealing System Updated Instructions for Use (IFU)

Important Update to Field Safety Notice Nellix EndoVascular Aneurysm Sealing System Updated Instructions for Use (IFU) October 6, 2017 Important Update to Field Safety Notice Nellix EndoVascular Aneurysm Sealing System Updated Instructions for Use (IFU) Dear Physician, This notification is to provide you with further information

More information

Aortic Neck Issues Associated Clinical Sequelae/Implications for Graft Choice

Aortic Neck Issues Associated Clinical Sequelae/Implications for Graft Choice Aortic Neck Issues Associated Clinical Sequelae/Implications for Graft Choice Eric Verhoeven, MD, PhD, A. Katsargyris, MD Department of Vascular and Endovascular Surgery, Paracelsus Medical University,

More information

ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients

ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients The Ovation System is approved to treat infrarenal abdominal aortic aneurysms and is not

More information

Current Status of EVAR for Infrarenal AAA. 31 st Annual Florida Vascular Society. PENN Surgery

Current Status of EVAR for Infrarenal AAA. 31 st Annual Florida Vascular Society. PENN Surgery Current Status of EVAR for Infrarenal AAA 31 st Annual Florida Vascular Society PENN Surgery No Disclosures Stent Grafts Design Related Differences What really matters? Modular Unibody Supported Unsupported

More information

Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC

Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC Interventional Cardiologist/Endovascular Specialist Bradenton Cardiology Center Bradenton, FL, USA Disclosures

More information

Chimney endovascular aneurysm sealing (ch-evas) for ruptured abdominal aortic aneurysms (AAA) due to type Ia endoleak following failed EVAS

Chimney endovascular aneurysm sealing (ch-evas) for ruptured abdominal aortic aneurysms (AAA) due to type Ia endoleak following failed EVAS Chimney endovascular aneurysm sealing (ch-evas) for ruptured abdominal aortic aneurysms (AAA) due to type Ia endoleak following failed EVAS Saritphat Orrapin MD FRCS (Thailand), Thoetphum Benyakorn, Tunyarat

More information

No Neck Is Needed! Treat the Aneurysm Instead! Andrew Holden, MD Associate Professor of Radiology Auckland City Hospital

No Neck Is Needed! Treat the Aneurysm Instead! Andrew Holden, MD Associate Professor of Radiology Auckland City Hospital No Neck Is Needed! Treat the Aneurysm Instead! Andrew Holden, MD Associate Professor of Radiology Auckland City Hospital Disclosures Andrew Holden, MBChB, FRANZCR No financial investment to disclose Investigator

More information

Lessons learned from Ch-EVAR for the treatment of. Miltos Matsagkas MD, PhD, FEBVS Professor of Vascular Surgery University of Thessaly

Lessons learned from Ch-EVAR for the treatment of. Miltos Matsagkas MD, PhD, FEBVS Professor of Vascular Surgery University of Thessaly Lessons learned from Ch-EVAR for the treatment of pararenal AAAs Miltos Matsagkas MD, PhD, FEBVS Professor of Vascular Surgery University of Thessaly Ch-EVAR Ch-EVAR = Chimney-EVAR Placement of single

More information

Improving Endograft Durability with EndoAnchors

Improving Endograft Durability with EndoAnchors Improving Endograft Durability with EndoAnchors William D. Jordan, Jr., M.D. John E. Skandalakis Chair in Surgery Professor and Chief Division of Vascular Surgery and Endovascular Therapy Emory University

More information

CAUTION: The Nellix EndoVascular Aneurysm Sealing System is an investigational device. Limited by federal (or United States) law to investigational

CAUTION: The Nellix EndoVascular Aneurysm Sealing System is an investigational device. Limited by federal (or United States) law to investigational Safety and Effectiveness Results of the Nellix System IDE Pivotal Trial for Endovascular Aneurysm Sealing PRESENTED BY: Jeffrey P. Carpenter, MD National Principal Investigator Professor and Chairman,

More information

Why Nellix? Treating Concomitant Common Iliac Aneurysms

Why Nellix? Treating Concomitant Common Iliac Aneurysms INDICATIONS FOR USE The Nellix EndoVascular Aneurysm Sealing System can be used in patients who have an infrarenal abdominal aortic (AAA) or aortoiliac aneurysm with suitable anatomy as indicated below:

More information

Mid-term results from ANCHOR: How does this data influence the treatment algorithm for hostile EVAR anatomies

Mid-term results from ANCHOR: How does this data influence the treatment algorithm for hostile EVAR anatomies Mid-term results from ANCHOR: How does this data influence the treatment algorithm for hostile EVAR anatomies Jean-Paul P.M. de Vries Head Department of Surgery, University Medical Centre Groningen The

More information

Predictors of abdominal aortic aneurysm sac enlargement after EVAR Longterm results from the ENGAGE Registry

Predictors of abdominal aortic aneurysm sac enlargement after EVAR Longterm results from the ENGAGE Registry Predictors of abdominal aortic aneurysm sac enlargement after EVAR Longterm results from the ENGAGE Registry D. Böckler Department of Vascular and Endovascular Surgery University Hospital Heidelberg Disclosure

More information

Mid-term results of 300+ patients treated by endovascular aortic sealing (EVAS)

Mid-term results of 300+ patients treated by endovascular aortic sealing (EVAS) Mid-term results of 300+ patients treated by endovascular aortic sealing (EVAS) Jean-Paul P.M. de Vries Dept Vascular Surgery St. Antonius Hospital, Nieuwegein,The Netherlands On behalf of the DEVASS study

More information

Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System,

Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System, Young-Guk Ko, M.D., Dangas G, J Am Coll Cardiol Intv 2012;5:1071 All-cause Mortality Dangas Severance G, J Am Coll Cardiovascular Cardiol Intv Hospital, 2012;5:1071 Yonsei University Health System Aneurysm-related

More information

Disclosures. EVAR follow-up: actual recommendation. EVAR follow-up: critical issues

Disclosures. EVAR follow-up: actual recommendation. EVAR follow-up: critical issues Disclosures is it time to discuss individualized follow-up schemes based on preoperative anatomy and high quality completion angiography? Consultant / Speaker / Proctor Cook Cordis Medtronic Invatec W.L.

More information

Access More Patients. Customize Each Seal.

Access More Patients. Customize Each Seal. Access More. Customize Each Seal. The Least Invasive Path Towards Proven Patency ULTRA LOW PROFILE TO EASE ADVANCEMENT The flexible, ultra-low 12F ID Ovation ix delivery system enables you to navigate

More information

14F OD Ovation Abdominal Stent Graft System

14F OD Ovation Abdominal Stent Graft System 14F OD Ovation Abdominal Stent Graft System 2 Year Results from the European Study Dierk Scheinert, MD Center for Vascular Medicine Angiology and Vascular Surgery Park Hospital Leipzig, Germany Disclosure

More information

Conflicts of Interest. When and Why Complex EVAR in Tx of juxta/suprarenal AAA? Summary. Infrarenal EVAR for short necks 2y postop

Conflicts of Interest. When and Why Complex EVAR in Tx of juxta/suprarenal AAA? Summary. Infrarenal EVAR for short necks 2y postop When and Why Complex EVAR in Tx of juxta/suprarenal AAA? Tim Resch MD Vascular Center Skane University Hospital Conflicts of Interest COOK Medical - Consulting, Speakers Bureau, IP, Research support Medtronic

More information

EVAS How does this Impact EVAR Therapy

EVAS How does this Impact EVAR Therapy EVAS How does this Impact EVAR Therapy John S. Lane III, MD, FACS Professor and Acting Chief of Vascular Surgery University of California, San Diego PNEC, 2017 Endologix products and associated components

More information

GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability. Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands

GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability. Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands Disclosure Speaker name: Michel Reijnen I have the following potential conflicts

More information

Optimizing Accuracy of Aortic Stent Grafts in Short Necks

Optimizing Accuracy of Aortic Stent Grafts in Short Necks Optimizing Accuracy of Aortic Stent Grafts in Short Necks Venkatesh Ramaiah, MD, FACS Medical Director Arizona Heart Hospital Director Peripheral Vascular and Endovascular Research Arizona Heart Institute

More information

EVAR Revision Setting - How can Heli-FX EndoAnchors improve the outcomes?

EVAR Revision Setting - How can Heli-FX EndoAnchors improve the outcomes? D. Böckler Department of Vascular and Endovascular Surgery University Hospital Heidelberg EVAR Revision Setting - How can Heli-FX EndoAnchors improve the outcomes? Disclosures Speaker name: Dittmar Böckler

More information

Type 1a Endoleak in hostile neck anatomies: Endoanchor can fix it! D. Böckler University Hospital Heidelberg, Germany

Type 1a Endoleak in hostile neck anatomies: Endoanchor can fix it! D. Böckler University Hospital Heidelberg, Germany Type 1a Endoleak in hostile neck anatomies: Endoanchor can fix it! D. Böckler University Hospital Heidelberg, Germany Disclosures Speaker name: Dittmar Böckler I have the following potential conflicts

More information

Ovation. Sean Lyden, MD Department Chair, Vascular Surgery Cleveland Clinic

Ovation. Sean Lyden, MD Department Chair, Vascular Surgery Cleveland Clinic Ovation Sean Lyden, MD Department Chair, Vascular Surgery Cleveland Clinic Disclosure Statement of Financial Interest Within the past 12 months, I or my spouse/partner have had a financial interest/arrangement

More information

How to Categorize the Infrarenal Neck Properly? I Van Herzeele Dept. Thoracic and Vascular Surgery, Ghent University, Belgium

How to Categorize the Infrarenal Neck Properly? I Van Herzeele Dept. Thoracic and Vascular Surgery, Ghent University, Belgium How to Categorize the Infrarenal Neck Properly? I Van Herzeele Dept. Thoracic and Vascular Surgery, Ghent University, Belgium Disclosure Speaker name: Isabelle Van Herzeele I have the following potential

More information

EVAS is Associated with Lower All-Cause Mortality

EVAS is Associated with Lower All-Cause Mortality EVAS is Associated with Lower All-Cause Mortality Marc L Schermerhorn, MD Chief, Division of Vascular and Endovascular Surgery Beth Israel Deaconess Medical Center Professor of Surgery Harvard Medical

More information

Less Invasive EVAR Transitioning to a Fast-Track Protocol

Less Invasive EVAR Transitioning to a Fast-Track Protocol Less Invasive EVAR Transitioning to a Fast-Track Protocol Mario Lachat, MD University of Zurich Department of Cardiovascular Surgery Switzerland LINC 2015 1 Disclosure Speaker name: Mario Lachat, MD I

More information

How to select FEVAR versus EVAR + endoanchors in short-necked AAAs

How to select FEVAR versus EVAR + endoanchors in short-necked AAAs How to select FEVAR versus EVAR + endoanchors in short-necked AAAs Jean-Paul P.M. de Vries, Richte C.L. Schuurmann St. Antonius Hospital Nieuwegein, The Netherlands 21st Critical Issues Congress Nuernberg,

More information

LOWERING THE PROFILE RAISING THE BAR

LOWERING THE PROFILE RAISING THE BAR LOWERING THE PROFILE RAISING THE BAR INNOVATIVE LOW PROFILE. ADVANCED CLINICAL PERFORMANCE. The AFX TM Endovascular AAA System integrates anatomical fixation with an advanced delivery system and graft

More information

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ History of the Powerlink System Design and Clinical Results Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ Powerlink System: Unibody-Bifurcated Design Long Main Body Low-Porosity Proprietary eptfe

More information

Hostile Neck During EVAR, The Role Of Endoanchores

Hostile Neck During EVAR, The Role Of Endoanchores Hostile Neck During EVAR, The Role Of Endoanchores Samer Koussayer, MD, FACS, RVT Prof, Al Faisal University Section Head and consultant Vascular & Endovascular Surgery Division King Faisal Specialist

More information

When to use standard EVAR with EndoAnchors or CHEVAR in short-neck AAAs LINC ASIA 18

When to use standard EVAR with EndoAnchors or CHEVAR in short-neck AAAs LINC ASIA 18 When to use standard EVAR with EndoAnchors or CHEVAR in short-neck AAAs JEAN-PAUL P.M. DE VRIES, DIRECTOR OF VASCULAR SURGERY ST.ANTONIUS HOSPITAL NIEUWEGEIN, THE NETHERLANDS. LINC ASIA-PACIFIC HongKong,

More information

Considerations for a Durable Repair

Considerations for a Durable Repair Considerations for a Durable Repair Eric Verhoeven, MD, PhD, A. Katsargyris, MD Department of Vascular and Endovascular Surgery, Paracelsus Medical University, Nuremberg, Germany Disclosures William Cook

More information

EVAS Sealing Technology: The new paradigm in AAA therapy

EVAS Sealing Technology: The new paradigm in AAA therapy June 2016 EDUCATIONAL SUPPLEMENT EVAS Sealing Technology: The new paradigm in AAA therapy This educational supplement has been supported by an unrestricted educational grant from Endologix MM1398 Rev 01

More information

Durability of The Endurant Stent-Graft through 5 Years

Durability of The Endurant Stent-Graft through 5 Years Durability of The Endurant Stent-Graft through 5 Years Michel S. Makaroun MD Co-Director, UPMC Heart and Vascular Institute Professor and Chair, Division of Vascular Surgery University of Pittsburgh School

More information

Is EVAS a proper choice in women?

Is EVAS a proper choice in women? Is EVAS a proper choice in women? CACVS 2018 Jan MM Heyligers, PhD, FEBVS Consultant Vascular Surgeon Elisabeth TweeSteden Hospital Tilburg The Netherlands Disclosures Consultant for Endologix DEVASS =Dutch

More information

Hostile Proximal Neck: A New Conformable EVAR Device

Hostile Proximal Neck: A New Conformable EVAR Device Hostile Proximal Neck: A New Conformable EVAR Device Young-Guk Ko, M.D., Seoul, Korea Currently Available Devices for EVAR in Korea, 2018 Zenith Flex, Cook Endurant IIs, Medtronic INCRAFT, Cordis AFX2,

More information

TriVascular Ovation Prime Abdominal Stent Graft System

TriVascular Ovation Prime Abdominal Stent Graft System TriVascular Ovation Prime Abdominal Stent Graft System Science of the Seal O-Ring Sealing Technology O-Ring Sealing in Proven Engineering Solutions O-rings are designed to seal by blocking the flow of

More information

Abdominal and thoracic aneurysm repair

Abdominal and thoracic aneurysm repair Abdominal and thoracic aneurysm repair William A. Gray MD Director, Endovascular Intervention Cardiovascular Research Foundation Columbia University Medical Center Abdominal Aortic Aneurysm Endografts

More information

My personal experience with INCRAFT in standard and challenging cases

My personal experience with INCRAFT in standard and challenging cases My personal experience with INCRAFT in standard and challenging cases G Pratesi, MD Vascular Surgery University of Rome Tor Vergata giovanni.pratesi@uniroma2.it Disclosure Speaker name: Giovanni Pratesi,

More information

Analysis of Type IIIb Endoleaks Encountered with Endologix Endografts

Analysis of Type IIIb Endoleaks Encountered with Endologix Endografts Analysis of Type IIIb Endoleaks Encountered with Endologix Endografts Alan R. Wladis, MD, FACS, David Varnagy, MD, FACS, Manuel R. Perez-Izquierdo, MD, Mark Ranson, MD FACS, Delos Clift, MD FACS, Rebecca

More information

Evolution of gender-related differences in outcome of EVAR

Evolution of gender-related differences in outcome of EVAR Evolution of gender-related differences in outcome of EVAR Erik Debing Department of Vascular Surgery University Hospital Brussels Disclosure Speaker name: ERIK DEBING... I have the following potential

More information

Degeneration of the Neck Post Implementation - a New Era of AAA Stent

Degeneration of the Neck Post Implementation - a New Era of AAA Stent Degeneration of the Neck Post Implementation - a New Era of AAA Stent New Mexico Heart Institute Albuquerque, New Mexico USA - Gore Current FDA-Approved EVAR Devices Sealing Mechanism Endologix Lombard

More information

Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment

Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment Robert Y. Rhee, MD Chief, Vascular and Endovascular Surgery Director, Aortic Center Maimonides Medical Center Brooklyn,

More information

Clinical trial and real-world outcomes of an endovascular iliac aneurysm repair with the GORE Iliac Branch Endoprosthesis (IBE)

Clinical trial and real-world outcomes of an endovascular iliac aneurysm repair with the GORE Iliac Branch Endoprosthesis (IBE) Clinical trial and real-world outcomes of an endovascular iliac aneurysm repair with the GORE Iliac Branch Endoprosthesis (IBE) Jan MM Heyligers, PhD, FEBVS Consultant Vascular Surgeon The Netherlands

More information

Endovascular Aneurysm Sealing: Early and Midterm Results From the EVAS FORWARD Global Registry

Endovascular Aneurysm Sealing: Early and Midterm Results From the EVAS FORWARD Global Registry 664365JETXXX10.1177/1526602816664365Journal of Endovascular TherapyThompson et al research-article2016 Clinical Investigation Endovascular Aneurysm Sealing: Early and Midterm Results From the EVAS FORWARD

More information

Use of Aptus Heli-FX EndoAnchor implants with standard endografts to strengthen seal in hostile anatomies:

Use of Aptus Heli-FX EndoAnchor implants with standard endografts to strengthen seal in hostile anatomies: Use of Aptus Heli-FX EndoAnchor implants with standard endografts to strengthen seal in hostile anatomies: technical tips, case experience and clinical results CACVS Medtronic Symposium Paris, France January

More information

INCRAFT system: Update from the Pivotal INSPIRATION Study

INCRAFT system: Update from the Pivotal INSPIRATION Study INCRAFT system: Update from the Pivotal INSPIRATION Study Michel S. Makaroun MD Co-Director, UPMC Heart and Vascular Institute Professor and Chair, Division of Vascular Surgery University of Pittsburgh

More information

Abdominal Aortic Aneurysm (AAA)

Abdominal Aortic Aneurysm (AAA) Abdominal Aortic Aneurysm (AAA) Vascular Workshop: Objectives Anatomy Keith VanHaltren Indications Technique Cases Abdominal Aorta: Normal Size Abdominal aortic aneurysm: Definition Normal diameter of

More information

A New EVAR Device for Infrarenal AAAs

A New EVAR Device for Infrarenal AAAs A New EVAR Device for Infrarenal AAAs Peter Nelson, MD, MS Assistant Professor of Surgery MM0203 Rev. 01 Current U.S. EVAR Devices Anatomical Fixation Proximal Fixation Powerlink - Endologix Excluder WL

More information

THE ENDURANT STENT GRAFT IN HOSTILE ANEURYSM NECK ANATOMY

THE ENDURANT STENT GRAFT IN HOSTILE ANEURYSM NECK ANATOMY THE ENDURANT STENT GRAFT IN HOSTILE ANEURYSM NECK ANATOMY Patrice Mwipatayi FCS (SA), MMed, FRACS Professor of Vascular surgery Royal Perth Hospital, University of Western Australia, Perth, WA Co-Authors:

More information

Reduction in cardiovascular related adverse events following active sac management with Nellix vs. EVAR: Are there biological advantages?

Reduction in cardiovascular related adverse events following active sac management with Nellix vs. EVAR: Are there biological advantages? February 1, 2018 Reduction in cardiovascular related adverse events following active sac management with Nellix vs. EVAR: Are there biological advantages? Patrick Berg M.D. Marienhospital Kevelaer Germany

More information

Feasibility of aortic neck anatomy for endovascular aneurysm repair in Korean patients with abdominal aortic aneurysm

Feasibility of aortic neck anatomy for endovascular aneurysm repair in Korean patients with abdominal aortic aneurysm LINC 2019 Leipzig, Germany Feasibility of aortic neck anatomy for endovascular aneurysm repair in Korean patients with abdominal aortic aneurysm Deokbi Hwang, Sujin Park, Hyung-Kee Kim, Seung Huh Division

More information

Hinchliffe, R. (2017). Aneurysm sealing. British Journal of Surgery, 104(2),

Hinchliffe, R. (2017). Aneurysm sealing. British Journal of Surgery, 104(2), Hinchliffe, R. (2017). Aneurysm sealing. British Journal of Surgery, 104(2), 163 165. https://doi.org/10.1002/bjs.10436 Peer reviewed version License (if available): Other Link to published version (if

More information

Endovascular Aneurysm Sealing System for Treating Abdominal Aortic Aneurysms: Early Outcomes from a Single Center

Endovascular Aneurysm Sealing System for Treating Abdominal Aortic Aneurysms: Early Outcomes from a Single Center Endovascular Aneurysm Sealing System for Treating Abdominal Aortic Aneurysms: Early Outcomes from a Single Center Thiti Chanmayka MD*, Anucha Ahooja MD**, Chalach Mitprachapranee MD*, Chawalit Wongbhuddha

More information

Observations on surveillance imaging after endovascular sealing of abdominal aortic aneurysms with the Nellix system

Observations on surveillance imaging after endovascular sealing of abdominal aortic aneurysms with the Nellix system Observations on surveillance imaging after endovascular sealing of abdominal aortic aneurysms with the Nellix system McWilliams, RG, Fisher, RK, England, A and Torella, F http://dx.doi.org/10.1177/1526602815582209

More information

Endovascular Repair o Abdominal. Aortic Aneurysms. Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida

Endovascular Repair o Abdominal. Aortic Aneurysms. Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida Endovascular Repair o Abdominal Aortic Aneurysms Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida Disclosure Nothing to disclose. 2 Mr. X AAA Mr. X. Is a 70 year old male who presented to

More information

2015 Clinical Update Endovascular Systems for AAA Repair

2015 Clinical Update Endovascular Systems for AAA Repair Endovascular Systems for AAA Repair 2 Musick Irvine, CA 92618 Tel 949.595.7200 Fax 949.612.1893 www.endologix.com TABLE OF CONTENTS Section Page ABSTRACT... 3 READER S GUIDE... 4 SECTION 1: US PIVOTAL

More information

Talent Abdominal Stent Graft

Talent Abdominal Stent Graft Talent Abdominal with THE Xcelerant Hydro Delivery System Expanding the Indications for EVAR Treat More Patients Short Necks The Talent Abdominal is the only FDA-approved device for proximal aortic neck

More information

From 1996 to 1999, a total of 1,193 patients with

From 1996 to 1999, a total of 1,193 patients with THE ANEURX CLINICAL TRIAL AT 8 YEARS Lessons learned following the US AneuRx clinical trial from 1996 to 2004. BY CHRISTOPHER K. ZARINS, MD From 1996 to 1999, a total of 1,193 patients with infrarenal

More information

Faculty Disclosure. Glue, Particulates, Thrombin, Coils and the Kitchen Sink for Type II Endoleak Management. Background.

Faculty Disclosure. Glue, Particulates, Thrombin, Coils and the Kitchen Sink for Type II Endoleak Management. Background. Glue, Particulates, Thrombin, Coils and the Kitchen Sink for Type II Endoleak Management Faculty Disclosure I disclose the following financial relationships: UCSF Vascular Symposium 2013 Receive grant/research

More information

Current Status of Abdominal Aortic Stent Grafts. John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center

Current Status of Abdominal Aortic Stent Grafts. John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center Current Status of Abdominal Aortic Stent Grafts John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center Autumn Greetings Disclosure Statement of Financial Interest Within

More information

Endovascular Aneurysm Sealing for the Treatment of Ruptured Abdominal Aortic Aneurysms

Endovascular Aneurysm Sealing for the Treatment of Ruptured Abdominal Aortic Aneurysms 582529JETXXX10.1177/1526602815582529Journal of Endovascular Therapyde Bruin et al research-article2015 Case Report Endovascular Aneurysm Sealing for the Treatment of Ruptured Abdominal Aortic Aneurysms

More information

What does the data tell us about outcomes of EVAR in challenging anatomy?

What does the data tell us about outcomes of EVAR in challenging anatomy? What does the data tell us about outcomes of EVAR in challenging anatomy? UCSF Vascular Surgery Symposium 2018 Sukgu M Han, MD, MS Assistant Professor of Clinical Surgery Co-director, Comprehensive Aortic

More information

FEVAR FIFTEEN YEARS OF EFFICIENCY E.DUCASSE MD PHD FEBVS CHU DE BORDEAUX

FEVAR FIFTEEN YEARS OF EFFICIENCY E.DUCASSE MD PHD FEBVS CHU DE BORDEAUX FEVAR FIFTEEN YEARS OF EFFICIENCY E.DUCASSE MD PHD FEBVS CHU DE BORDEAUX 2018 A BIT OF HISTORY First use of F-EVAR : 1990s Park et al. J Vasc Interv Radiol. 1996;7:819-823. Faruqi et al. J Endovasc Surg.

More information

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully Physician Training Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully supported by self-expanding z-stents H&L-B

More information

Description. Section: Surgery Effective Date: April 15, Subsection: Surgery Original Policy Date: December 6, 2012 Subject:

Description. Section: Surgery Effective Date: April 15, Subsection: Surgery Original Policy Date: December 6, 2012 Subject: Last Review Status/Date: March 2015 Page: 1 of 6 Description Wireless sensors implanted in an aortic aneurysm sac after endovascular repair are being investigated to measure post procedural pressure. It

More information

Increased Flexibility of AneuRx Stent-Graft Reduces Need for Secondary Intervention Following Endovascular Aneurysm Repair

Increased Flexibility of AneuRx Stent-Graft Reduces Need for Secondary Intervention Following Endovascular Aneurysm Repair 583 Increased Flexibility of AneuRx Stent-Graft Reduces Need for Secondary Intervention Following Endovascular Aneurysm Repair Frank R. Arko, MD; W. Anthony Lee, MD; Bradley B. Hill, MD; Paul Cipriano,

More information

Aorfix Pythagoras US Clinical Trial:

Aorfix Pythagoras US Clinical Trial: Overall 1 Year Results from the Aorfix Pythagoras US Clinical Trial: 1 st IDE Study in Highly Angulated 60 133 Aortic Necks Mark Fillinger MD for the PYTHAGORAS Investigators Disclosure Speaker name: Mark

More information

Bilateral use of the Gore IBE device for bilateral CIA aneurysms and a first interim analysis of the prospective Iceberg registry

Bilateral use of the Gore IBE device for bilateral CIA aneurysms and a first interim analysis of the prospective Iceberg registry Bilateral use of the Gore IBE device for bilateral CIA aneurysms and a first interim analysis of the prospective Iceberg registry Michel MPJ Reijnen, MD, PhD Department of Vascular Surgery, Rijnstate Hospital

More information

Insights from the PROTAGORAS/PERICLES Registries: impact on ChEVAR results

Insights from the PROTAGORAS/PERICLES Registries: impact on ChEVAR results Insights from the PROTAGORAS/PERICLES Registries: impact on ChEVAR results Konstantinos P. Donas, Giovanni Torsello Department of Vascular Surgery St. Franziskus Hospital Münster, Germany Disclosure Speaker

More information

Right Choice for Right Angles

Right Choice for Right Angles Right Choice for Right Angles The Anatomy of Technology Aorfix gives you technology that conforms to patient anatomy, optimising both procedure and post-operative performance. Fishmouth for optimum neck

More information

Now that Endoanchors are Approved (and paid for) We have a Durable Solution to Short Necks That s so Easy!

Now that Endoanchors are Approved (and paid for) We have a Durable Solution to Short Necks That s so Easy! Now that Endoanchors are Approved (and paid for) We have a Durable Solution to Short Necks That s so Easy! David H. Deaton, MD Vascular Surgery / University of South Carolina / Palmetto Health Chief Medical

More information

Endovascular Treatment of Symptomatic Abdominal Aortic Aneurysms

Endovascular Treatment of Symptomatic Abdominal Aortic Aneurysms 춘계심장학회, April 2013 Endovascular Treatment of Symptomatic Abdominal Aortic Aneurysms Seung-Hyuk Choi Division of Cardiology Samsung Medical Center SungKyunKwan Univ. Contents Introduction EVAR vs. Open

More information

EVAR replaced standard repair in most cases. Why?

EVAR replaced standard repair in most cases. Why? EVAR replaced standard repair in most cases. Why? Initial major steps in endograft evolution Papazoglou O. Konstantinos M.D. The story of a major breakthrough in vascular surgery 1991 Parodi introduces

More information

Endoanchor-assisted TEVAR

Endoanchor-assisted TEVAR Endoanchor-assisted TEVAR May 29, 2015 NCVH2015 Grayson H. Wheatley III, MD Director of Aortic and Endovascular Surgery Associate Professor of Surgery Temple University School of Medicine Disclosures Consultant

More information

Management of Endoleaks

Management of Endoleaks Management of Endoleaks Murray Shames, MD Professor and Chief, Director Tampa General Hospital Aortic Program Vice Chair of Research, Dept. of Surgery Conflict of Interests: Speaker: Gore, Medtronic, Cook

More information

Technique and Tips for Complicated AAA Cases with Stent Graft

Technique and Tips for Complicated AAA Cases with Stent Graft Technique and Tips for Complicated AAA Cases with Stent Graft Seung-Woon Rha, MD, PhD FACC, FAHA, FESC, FSCAI, FAPSIC Cardiovascular Center, Korea University Guro Hospital Mar 15, 2018 LINC AP 2018 Endoleak;

More information

Overcoming Challenging Aortic Anatomy: from Hostile Necks to Tortuous Iliac arteries

Overcoming Challenging Aortic Anatomy: from Hostile Necks to Tortuous Iliac arteries Overcoming Challenging Aortic Anatomy: from Hostile Necks to Tortuous Iliac arteries Robert Fisher Royal Liverpool University Hospital, UK Liverpool Vascular and Endovascular Service Introduction Late

More information

MODERN METHODS FOR TREATING ABDOMINAL ANEURYSMS AND THORACIC AORTIC DISEASE

MODERN METHODS FOR TREATING ABDOMINAL ANEURYSMS AND THORACIC AORTIC DISEASE MODERN METHODS FOR TREATING ABDOMINAL ANEURYSMS AND THORACIC AORTIC DISEASE AAA FACTS 200,000 New Cases Each Year Ruptured AAA = 15,000 Deaths per Year in U.S. 13th Leading Cause of Death 80% Chance of

More information

Anatomical challenges in EVAR

Anatomical challenges in EVAR Anatomical challenges in EVAR M.H. EL DESSOKI, MD,FRCS PROFESSOR OF VASCULAR SURGERY CAIRO UNIVERSITY Disclosure Speaker name:... I have the following potential conflicts of interest to report: Consulting

More information

NEW INNOVATIONS IN ENDOLEAK MANAGEMENT

NEW INNOVATIONS IN ENDOLEAK MANAGEMENT DISCLOSURES NEW INNOVATIONS IN ENDOLEAK MANAGEMENT Kelley HodgkissHarlow, MD, RPVI, FACS Vascular and Endovascular Surgery Kaiser Permanente, San Diego Nothing to disclose GOALS BACKGROUND Background Surveillance

More information

Abdominal Aortic Aneurysms. A Surgeons Perspective Dr. Derek D. Muehrcke

Abdominal Aortic Aneurysms. A Surgeons Perspective Dr. Derek D. Muehrcke Abdominal Aortic Aneurysms A Surgeons Perspective Dr. Derek D. Muehrcke Aneurysm Definition The abnormal enlargement or bulging of an artery caused by an injury or weakness in the blood vessel wall A localized

More information

AAA: DEBATE THERE ARE NO LIMITS USING EVAR FOR AAA. 2 nd -3 rd June 2016.

AAA: DEBATE THERE ARE NO LIMITS USING EVAR FOR AAA. 2 nd -3 rd June 2016. AAA: DEBATE THERE ARE NO LIMITS USING EVAR FOR AAA JORGE FERNÁNDEZ NOYA ANGIOLOGY AND VASCULAR SURGERY DEPARTMENT UNIVERSITARY CLINICAL HOSPITAL SANTIAGO DE COMPOSTELA 2 nd -3 rd June 2016. 1888 ENDOANEURYSMORRHAPHY

More information

The clinical update for the Zenith AAA Endovascular Graft has included results from the Zenith AAA Endovascular Graft multi-center clinical study,

The clinical update for the Zenith AAA Endovascular Graft has included results from the Zenith AAA Endovascular Graft multi-center clinical study, The clinical update for the Zenith AAA Endovascular Graft has included results from the Zenith AAA Endovascular Graft multi-center clinical study, the 36 mm diameter Zenith Flex AAA Endovascular Graft

More information

Case Report Early and Late Endograft Limb Proximal Migration with Resulting Type 1b Endoleak following an EVAR for Ruptured AAA

Case Report Early and Late Endograft Limb Proximal Migration with Resulting Type 1b Endoleak following an EVAR for Ruptured AAA Hindawi Case Reports in Vascular Medicine Volume 2017, Article ID 4931282, 5 pages https://doi.org/10.1155/2017/4931282 Case Report Early and Late Endograft Limb Proximal Migration with Resulting Type

More information

Technology. The introduction of endovascular aortic repair. cover story

Technology. The introduction of endovascular aortic repair. cover story Infrarenal EVAR Technology Review Steady evolution in device design and delivery has expanded endovascular repair to more patients, but further advancements are integral to this technology s future. By

More information

Standardization of the CHEVAR procedure: How a standard approach has improved outcomes. Prof Peter Holt St George s, London

Standardization of the CHEVAR procedure: How a standard approach has improved outcomes. Prof Peter Holt St George s, London Standardization of the CHEVAR procedure: How a standard approach has improved outcomes Prof Peter Holt St George s, London Disclosure Speaker name: Prof Peter Holt I have the following potential conflicts

More information

EXPERIENCE AFTER 500 ENDOLUMINAL STENT GRAFTS. DEVICES SPECIFIC OUTCOME AND LESSONS LEARNED.

EXPERIENCE AFTER 500 ENDOLUMINAL STENT GRAFTS. DEVICES SPECIFIC OUTCOME AND LESSONS LEARNED. EXPERIENCE AFTER 500 ENDOLUMINAL STENT GRAFTS. DEVICES SPECIFIC OUTCOME AND LESSONS LEARNED. A/Prof. B. Patrice Mwipatayi MD, MMed (Surg), MClinEd (Melb), FCS, FRACS Department of Vascular Surgery, Royal

More information

Ultrasound Evaluation after EVAR: (Trying to) Let the CAT Scan Out of the Bag

Ultrasound Evaluation after EVAR: (Trying to) Let the CAT Scan Out of the Bag Ultrasound Evaluation after EVAR: (Trying to) Let the CAT Scan Out of the Bag Joseph-Vincent V. Blas, MD Division of Vascular Surgery Department of Surgery Greenville Health System University of South

More information