The Ventana Off-the-Shelf Graft for Pararenal AAA. Andrew Holden Associate Professor of Radiology Auckland Hospital

Size: px
Start display at page:

Download "The Ventana Off-the-Shelf Graft for Pararenal AAA. Andrew Holden Associate Professor of Radiology Auckland Hospital"

Transcription

1 The Ventana Off-the-Shelf Graft for Pararenal AAA Andrew Holden Associate Professor of Radiology Auckland Hospital

2 Disclosures Andrew Holden, MBChB, FRANZCR Investigator in Nellix and Ventana Trials Clinical Consultant to Endologix

3 Ventana Fenestrated System Designed for Broad Range of Anatomies Fenestrations are movable in situ Integrated System Pre-cannulated fenestrations with 6Fr sheaths Renal Stent Grafts compatible with 6Fr sheaths 120-cm length, 6Fr compatible angiographic catheters Anatomical Fixation For foundational stability and bifurcation preservation 22Fr OD delivery system

4 Procedure Steps Outer sheath retracted and 6Fr sheath exposure RA cannulation with device fully constrained Proximal deployment with reference to SMA (encompass SMA and celiac) Distal deployment to overlap bifurcated body Covered renal stent positioning, expansion, and flaring

5

6 Ventana Clinical Program Overview Enrolled 15 2 sites Pilot Enrolled 34 8 sites Feasibility Enrolled sites US IDE Total Enrollment = 125 Compassionate Use =

7 Ventana Initial Clinical Experience Enrollment (N=15) 11/10 08/11 Holden A, et al. J Vasc Surg 2013;57:

8 Ventana CE Trial Enrollment (N=31) 11/10 04/12 Adequate iliac /femoral artery access Renal arteries with length 13mm, diameters 4 to 8mm, and with <70% ostial stenosis Absence of essential accessory renal artery (supplies <25% of parenchyma) Limited suprarenal mural thrombus Infra-SMA neck length 15mm, diameter 18 to 34mm, angle to the aneurysm sac 60 Renal arteries 0 to 35mm below the SMA, within ±30mm and 90 to 210 (clock) Celiac artery to SMA angle 60 (clock) SMA to bifurcation length 90mm Ventana overlap with bifurcated device at least 3cm length

9 CE Trial Sites Indiana University A. Sawchuk, MD Cleveland Clinic M. Eagleton, MD St. George s Institute M. Thompson, MD Hôpital Mondor JP Becquemin, MD UCLA Medical Ctr W. Quiñones-Baldrich, MD Pontifica Universidad Católica R. Mertens, MD Auckland City Hospital A. Holden, MD

10 Anatomical Baseline Characteristics Parameter Mean ± SD (Range) N=31 Sac Diameter, cm 6.0 ± 0.9 (4.9, 10) Infra-SMA Neck Length (mm) 27 ± 11 (9, 35) Infra-SMA Neck Diameter (mm) 25 ± 2.8 (21, 30) Infra-renal Neck Length (mm) 6.9 ±3.4 (0, 14) Infra-SMA to Sac Angle, 36 ± 12 (20, 53) SMA to Celiac Artery, (clockface) 14 ± 9.0 (0.8, 30) L to R Renal Artery, (clockface) 148 ± 25 (96, 204) L to R Renal Artery Length (mm) 6.6 ±5.0 (0, 20)

11 Major Adverse Events at 30 Days Event Ventana Endograft 1 (n=31) Infrarenal Endograft 2 (n=192) Open Surgical Control 2 (n=66) Patients with >1 MAE 5 (16%) 16 (8.3%) 44 (67%) All Cause Mortality 0 2 (1.0%) 4 (6.1%) Bowel Ischemia (9.1%) Myocardial Infarction 0 3 (1.5%) 5 (7.6%) Paraplegia Renal Failure 0 2 (1.0%) 6 (9.1%) Respiratory Failure 1 (3.2%) 2 (1.0%) 5 (7.6%) Stroke (1.5%) Blood Loss > 1,000cc 4 (13%) 11 (5.7%) 38 (58%) 1 Quinones-Baldrich W, et al. J Vasc Surg 2013 (in press). 2 Carpenter JP, et al. J Endovasc Ther 2010;17:

12 Results >30 Days to 18 Months Device Performance in 30-properly selected patients o No Conversion to Open or Aneurysm Rupture o No Type I, III, IV Endoleaks o No Migration or Aneurysm Sac Expansion o No aneurysm-related death Secondary Procedure (n=4) 1. Liquid embolization (n=1) for endoleak of unknown origin 2. Balloon angioplasty and self expanding stent deployment (n=2) for distal renal artery stenosis 3. Renal bypass due to device movement and bilateral stent fracture (n=1) Renal re-intervention 3/31 (9.7%)

13 Post f-evar Renal Re-Intervention Author Reference Number of Centers N Mean follow up (mos) Renal Reintervention Rate O Neill EJVES % Greenberg JVS % Verhoeven EJVES % Amiot EJVES % Vallabhaneni Circulation % Mastracci JVS % Quinones- Baldrich JVS %

14 Ventana Clinical Experience CE Trial and OUS Experience US IDE Experience

15 Ventana Interim IDE Observations Baseline Aneurysm Characteristics Parameter Maximum aneurysm diameter (mm) Infra-SMA neck length (mm) Infra-renal neck length (mm) Infra-SMA to aneurysm sac angle ( ) SMA to aortic bifurcation length (mm) Renal-renal angulation ( ) Total 58.4 ±7.9 (43.8, 91.8) 26.1 ±3.3 (17.6, 33.7) 4.1 ±8.2 (-49.4, 18.7) 32.2 ±12.9 (4.8, 58.8) ±17.0 (101.8, 179.5) ±27.4 (85.6, 214.3)

16 All procedures completed successfully US IDE Trial Cohort is free from rupture or conversion to open repair Core Lab (CCF PVCL) identifies no type I/III endoleak, gross migration, or sac diameter enlargement Major Adverse Events 0-30 Days (N=74 Enrolled) 31 Dy to 1 Yr (N=61) Pts. with 1 MAE 8 (11%) 2 (3.3%) All-Cause Mortality 2 (2.7%) 1 (1.6%) Bowel Ischemia 1 (1.4%) 0 Myocardial Infarction 2 (2.7%) 0 Paraplegia 0 0 Renal Failure 5 (6.8%) 1 (1.6%) Respiratory Failure 2 (2.7%) 1 (1.6%) Blood Loss >1,000cc 3 (4.1%) ---

17 Considerations in Renal Artery Stenting Pre SES Stenting - Expiration Pre SES Stenting - Inspiration Post SES Stenting - Expiration Post SES Stenting - Inspiration

18 5mm *Fenestration Marker

19 Before 59mm X 54mm 1 Month 58mm X 53mm 6 Months 55mm X 52mm 12 Months 53mm X 51mm

20 Conclusion The multicenter experience supports the early safety and feasibility of the ready to implant Ventana Fenestrated System in selected patients with juxtarenal AAA Because of some of the device issues, Endologix has paused enrolment in the US IDE Trial as well as the European launch Re-release of Ventana will occur once the company are satisfied durable solutions have been reached

The Auckland Experience with the Nellix EVAS System. Andrew Holden, MBChB, FRANZCR

The Auckland Experience with the Nellix EVAS System. Andrew Holden, MBChB, FRANZCR The Auckland Experience with the Nellix EVAS System Andrew Holden, MBChB, FRANZCR Disclosure Speaker name: Associate Professor Andrew Holden I have the following potential conflicts of interest to report:

More information

EndoVascular Aneurysm Sealing (EVAS) with Nellix

EndoVascular Aneurysm Sealing (EVAS) with Nellix 1 2 EndoVascular Aneurysm Sealing (EVAS) with Nellix Designed to seal entire aneurysm with contained biostable polymer Non-modular design with complete fixation Expands endovascular patient eligibility

More information

Nellix Endovascular System: Clinical Outcomes and Device Overview

Nellix Endovascular System: Clinical Outcomes and Device Overview Nellix Endovascular System: Clinical Outcomes and Device Overview Jeffrey P. Carpenter, MD Professor and Chief, Department of Surgery CAUTION: Investigational device. This product is under clinical investigation

More information

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ History of the Powerlink System Design and Clinical Results Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ Powerlink System: Unibody-Bifurcated Design Long Main Body Low-Porosity Proprietary eptfe

More information

No Neck Is Needed! Treat the Aneurysm Instead! Andrew Holden, MD Associate Professor of Radiology Auckland City Hospital

No Neck Is Needed! Treat the Aneurysm Instead! Andrew Holden, MD Associate Professor of Radiology Auckland City Hospital No Neck Is Needed! Treat the Aneurysm Instead! Andrew Holden, MD Associate Professor of Radiology Auckland City Hospital Disclosures Andrew Holden, MBChB, FRANZCR No financial investment to disclose Investigator

More information

A New EVAR Device for Infrarenal AAAs

A New EVAR Device for Infrarenal AAAs A New EVAR Device for Infrarenal AAAs Peter Nelson, MD, MS Assistant Professor of Surgery MM0203 Rev. 01 Current U.S. EVAR Devices Anatomical Fixation Proximal Fixation Powerlink - Endologix Excluder WL

More information

Treatment options of late failures of EVAS. Michel Reijnen Rijnstate Arnhem The Netherlands

Treatment options of late failures of EVAS. Michel Reijnen Rijnstate Arnhem The Netherlands Treatment options of late failures of EVAS Michel Reijnen Rijnstate Arnhem The Netherlands Disclosure Speaker name: Michel Reijnen I have the following potential conflicts of interest to report: Consulting

More information

INCRAFT system: Update from the Pivotal INSPIRATION Study

INCRAFT system: Update from the Pivotal INSPIRATION Study INCRAFT system: Update from the Pivotal INSPIRATION Study Michel S. Makaroun MD Co-Director, UPMC Heart and Vascular Institute Professor and Chair, Division of Vascular Surgery University of Pittsburgh

More information

Aortic Neck Issues Associated Clinical Sequelae/Implications for Graft Choice

Aortic Neck Issues Associated Clinical Sequelae/Implications for Graft Choice Aortic Neck Issues Associated Clinical Sequelae/Implications for Graft Choice Eric Verhoeven, MD, PhD, A. Katsargyris, MD Department of Vascular and Endovascular Surgery, Paracelsus Medical University,

More information

Durability of The Endurant Stent-Graft through 5 Years

Durability of The Endurant Stent-Graft through 5 Years Durability of The Endurant Stent-Graft through 5 Years Michel S. Makaroun MD Co-Director, UPMC Heart and Vascular Institute Professor and Chair, Division of Vascular Surgery University of Pittsburgh School

More information

FEVAR FIFTEEN YEARS OF EFFICIENCY E.DUCASSE MD PHD FEBVS CHU DE BORDEAUX

FEVAR FIFTEEN YEARS OF EFFICIENCY E.DUCASSE MD PHD FEBVS CHU DE BORDEAUX FEVAR FIFTEEN YEARS OF EFFICIENCY E.DUCASSE MD PHD FEBVS CHU DE BORDEAUX 2018 A BIT OF HISTORY First use of F-EVAR : 1990s Park et al. J Vasc Interv Radiol. 1996;7:819-823. Faruqi et al. J Endovasc Surg.

More information

Lessons learned from Ch-EVAR for the treatment of. Miltos Matsagkas MD, PhD, FEBVS Professor of Vascular Surgery University of Thessaly

Lessons learned from Ch-EVAR for the treatment of. Miltos Matsagkas MD, PhD, FEBVS Professor of Vascular Surgery University of Thessaly Lessons learned from Ch-EVAR for the treatment of pararenal AAAs Miltos Matsagkas MD, PhD, FEBVS Professor of Vascular Surgery University of Thessaly Ch-EVAR Ch-EVAR = Chimney-EVAR Placement of single

More information

My personal experience with INCRAFT in standard and challenging cases

My personal experience with INCRAFT in standard and challenging cases My personal experience with INCRAFT in standard and challenging cases G Pratesi, MD Vascular Surgery University of Rome Tor Vergata giovanni.pratesi@uniroma2.it Disclosure Speaker name: Giovanni Pratesi,

More information

Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System,

Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System, Young-Guk Ko, M.D., Dangas G, J Am Coll Cardiol Intv 2012;5:1071 All-cause Mortality Dangas Severance G, J Am Coll Cardiovascular Cardiol Intv Hospital, 2012;5:1071 Yonsei University Health System Aneurysm-related

More information

ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients

ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients The Ovation System is approved to treat infrarenal abdominal aortic aneurysms and is not

More information

Ventana Fenestrated Stent-Graft System for Endovascular Repair of Juxtarenal Aortic Aneurysms

Ventana Fenestrated Stent-Graft System for Endovascular Repair of Juxtarenal Aortic Aneurysms J ENDOVASC THER 173 TECHNICAL NOTE Ventana Fenestrated Stent-Graft System for Endovascular Repair of Juxtarenal Aortic Aneurysms Renato Mertens, MD; Michel Bergoeing, MD; Leopoldo Mariné, MD; Francisco

More information

LOWERING THE PROFILE RAISING THE BAR

LOWERING THE PROFILE RAISING THE BAR LOWERING THE PROFILE RAISING THE BAR INNOVATIVE LOW PROFILE. ADVANCED CLINICAL PERFORMANCE. The AFX TM Endovascular AAA System integrates anatomical fixation with an advanced delivery system and graft

More information

Associate Professor Walter W. Buckley Endowed Chair in Research Cleveland Clinic Lerner College of Medicine-CWRU. Houston Aortic Symposium 2017

Associate Professor Walter W. Buckley Endowed Chair in Research Cleveland Clinic Lerner College of Medicine-CWRU. Houston Aortic Symposium 2017 Matthew J. Eagleton, MD Associate Professor Walter W. Buckley Endowed Chair in Research Cleveland Clinic Lerner College of Medicine-CWRU Houston Aortic Symposium 2017 Aortica: Advisory Board Centerline

More information

CAUTION: The Nellix EndoVascular Aneurysm Sealing System is an investigational device. Limited by federal (or United States) law to investigational

CAUTION: The Nellix EndoVascular Aneurysm Sealing System is an investigational device. Limited by federal (or United States) law to investigational Safety and Effectiveness Results of the Nellix System IDE Pivotal Trial for Endovascular Aneurysm Sealing PRESENTED BY: Jeffrey P. Carpenter, MD National Principal Investigator Professor and Chairman,

More information

Ovation. Sean Lyden, MD Department Chair, Vascular Surgery Cleveland Clinic

Ovation. Sean Lyden, MD Department Chair, Vascular Surgery Cleveland Clinic Ovation Sean Lyden, MD Department Chair, Vascular Surgery Cleveland Clinic Disclosure Statement of Financial Interest Within the past 12 months, I or my spouse/partner have had a financial interest/arrangement

More information

Conflicts of Interest. When and Why Complex EVAR in Tx of juxta/suprarenal AAA? Summary. Infrarenal EVAR for short necks 2y postop

Conflicts of Interest. When and Why Complex EVAR in Tx of juxta/suprarenal AAA? Summary. Infrarenal EVAR for short necks 2y postop When and Why Complex EVAR in Tx of juxta/suprarenal AAA? Tim Resch MD Vascular Center Skane University Hospital Conflicts of Interest COOK Medical - Consulting, Speakers Bureau, IP, Research support Medtronic

More information

Off-the-Shelf Devices. Mark A Farber, MD FACS Director, Aortic Center Professor of Radiology and Surgery University of North Carolina

Off-the-Shelf Devices. Mark A Farber, MD FACS Director, Aortic Center Professor of Radiology and Surgery University of North Carolina Off-the-Shelf Devices Mark A Farber, MD FACS Director, Aortic Center Professor of Radiology and Surgery University of North Carolina Disclosures Cook - Research Support, Consultant, Clinical Trials WL

More information

EVAR replaced standard repair in most cases. Why?

EVAR replaced standard repair in most cases. Why? EVAR replaced standard repair in most cases. Why? Initial major steps in endograft evolution Papazoglou O. Konstantinos M.D. The story of a major breakthrough in vascular surgery 1991 Parodi introduces

More information

How to select FEVAR versus EVAR + endoanchors in short-necked AAAs

How to select FEVAR versus EVAR + endoanchors in short-necked AAAs How to select FEVAR versus EVAR + endoanchors in short-necked AAAs Jean-Paul P.M. de Vries, Richte C.L. Schuurmann St. Antonius Hospital Nieuwegein, The Netherlands 21st Critical Issues Congress Nuernberg,

More information

Optimizing Accuracy of Aortic Stent Grafts in Short Necks

Optimizing Accuracy of Aortic Stent Grafts in Short Necks Optimizing Accuracy of Aortic Stent Grafts in Short Necks Venkatesh Ramaiah, MD, FACS Medical Director Arizona Heart Hospital Director Peripheral Vascular and Endovascular Research Arizona Heart Institute

More information

14F OD Ovation Abdominal Stent Graft System

14F OD Ovation Abdominal Stent Graft System 14F OD Ovation Abdominal Stent Graft System 2 Year Results from the European Study Dierk Scheinert, MD Center for Vascular Medicine Angiology and Vascular Surgery Park Hospital Leipzig, Germany Disclosure

More information

Influence of patient selection and IFU compliance on outcomes following EVAS

Influence of patient selection and IFU compliance on outcomes following EVAS Influence of patient selection and IFU compliance on outcomes following EVAS LUNCH SYMPOSIUM LINC 2017 Jan MM Heyligers, MD, PhD, FEBVS Consultant Vascular Surgeon Elisabeth TweeSteden Hospital Tilburg,

More information

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE GUIDANCE EXECUTIVE (GE)

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE GUIDANCE EXECUTIVE (GE) NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE GUIDANCE EXECUTIVE (GE) Review of TA167; Endovascular stent-grafts for abdominal aortic aneurysms Final recommendation post consultation The guidance should

More information

EVAS is Associated with Lower All-Cause Mortality

EVAS is Associated with Lower All-Cause Mortality EVAS is Associated with Lower All-Cause Mortality Marc L Schermerhorn, MD Chief, Division of Vascular and Endovascular Surgery Beth Israel Deaconess Medical Center Professor of Surgery Harvard Medical

More information

When to use standard EVAR with EndoAnchors or CHEVAR in short-neck AAAs LINC ASIA 18

When to use standard EVAR with EndoAnchors or CHEVAR in short-neck AAAs LINC ASIA 18 When to use standard EVAR with EndoAnchors or CHEVAR in short-neck AAAs JEAN-PAUL P.M. DE VRIES, DIRECTOR OF VASCULAR SURGERY ST.ANTONIUS HOSPITAL NIEUWEGEIN, THE NETHERLANDS. LINC ASIA-PACIFIC HongKong,

More information

EVAS using Nellix in my practice Where are we today?

EVAS using Nellix in my practice Where are we today? EVAS using Nellix in my practice Where are we today? Prof. dr. Michel MPJ Reijnen Department of Vascular Surgery, Rijnstate Hospital Arnhem Faculty of Science and Technology, University of Twente The Netherlands

More information

GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability. Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands

GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability. Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands Disclosure Speaker name: Michel Reijnen I have the following potential conflicts

More information

Improving Endograft Durability with EndoAnchors

Improving Endograft Durability with EndoAnchors Improving Endograft Durability with EndoAnchors William D. Jordan, Jr., M.D. John E. Skandalakis Chair in Surgery Professor and Chief Division of Vascular Surgery and Endovascular Therapy Emory University

More information

Mid-term results of 300+ patients treated by endovascular aortic sealing (EVAS)

Mid-term results of 300+ patients treated by endovascular aortic sealing (EVAS) Mid-term results of 300+ patients treated by endovascular aortic sealing (EVAS) Jean-Paul P.M. de Vries Dept Vascular Surgery St. Antonius Hospital, Nieuwegein,The Netherlands On behalf of the DEVASS study

More information

Talent Abdominal Stent Graft

Talent Abdominal Stent Graft Talent Abdominal with THE Xcelerant Hydro Delivery System Expanding the Indications for EVAR Treat More Patients Short Necks The Talent Abdominal is the only FDA-approved device for proximal aortic neck

More information

NASDAQ: ELGX December Innovation that Empowers

NASDAQ: ELGX  December Innovation that Empowers NASDAQ: ELGX www.endologix.com December 2014 Innovation that Empowers Safe Harbor This presentation contains forward-looking statements within the meaning of the Private Securities Litigation Reform Act

More information

Robert F. Cuff, MD FACS SHMG Vascular Surgery

Robert F. Cuff, MD FACS SHMG Vascular Surgery Robert F. Cuff, MD FACS SHMG Vascular Surgery Objectives To become familiar with the commercially available fenestrated EVAR graft Discuss techniques to increase success Review available data to determine

More information

Bilateral use of the Gore IBE device for bilateral CIA aneurysms and a first interim analysis of the prospective Iceberg registry

Bilateral use of the Gore IBE device for bilateral CIA aneurysms and a first interim analysis of the prospective Iceberg registry Bilateral use of the Gore IBE device for bilateral CIA aneurysms and a first interim analysis of the prospective Iceberg registry Michel MPJ Reijnen, MD, PhD Department of Vascular Surgery, Rijnstate Hospital

More information

What's on the Horizon for AAA: Unilateral & Percutaneous, "UP-EVAR" System Zoran Rancic M.D., Ph.D.

What's on the Horizon for AAA: Unilateral & Percutaneous, UP-EVAR System Zoran Rancic M.D., Ph.D. What's on the Horizon for AAA: Unilateral & Percutaneous, "UP-EVAR" System Zoran Rancic M.D., Ph.D. Clinic for Cardiovascular Surgery University Hospital Zurich DISCLOSURES COMMON SITUATIONS FOR UNILATERAL

More information

Considerations for a Durable Repair

Considerations for a Durable Repair Considerations for a Durable Repair Eric Verhoeven, MD, PhD, A. Katsargyris, MD Department of Vascular and Endovascular Surgery, Paracelsus Medical University, Nuremberg, Germany Disclosures William Cook

More information

Hostile Proximal Neck: A New Conformable EVAR Device

Hostile Proximal Neck: A New Conformable EVAR Device Hostile Proximal Neck: A New Conformable EVAR Device Young-Guk Ko, M.D., Seoul, Korea Currently Available Devices for EVAR in Korea, 2018 Zenith Flex, Cook Endurant IIs, Medtronic INCRAFT, Cordis AFX2,

More information

for Thoracoabdominal Aneurysms

for Thoracoabdominal Aneurysms Durability of F/BEVAR for Thoracoabdominal Aneurysms Athanasios Katsargyris, MD, Eric Verhoeven MD, PhD Department of Vascular and Endovascular Surgery Paracelsus Medical University, Nuremberg, Germany

More information

Endovascular Repair o Abdominal. Aortic Aneurysms. Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida

Endovascular Repair o Abdominal. Aortic Aneurysms. Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida Endovascular Repair o Abdominal Aortic Aneurysms Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida Disclosure Nothing to disclose. 2 Mr. X AAA Mr. X. Is a 70 year old male who presented to

More information

Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC

Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC Interventional Cardiologist/Endovascular Specialist Bradenton Cardiology Center Bradenton, FL, USA Disclosures

More information

Feasibility of aortic neck anatomy for endovascular aneurysm repair in Korean patients with abdominal aortic aneurysm

Feasibility of aortic neck anatomy for endovascular aneurysm repair in Korean patients with abdominal aortic aneurysm LINC 2019 Leipzig, Germany Feasibility of aortic neck anatomy for endovascular aneurysm repair in Korean patients with abdominal aortic aneurysm Deokbi Hwang, Sujin Park, Hyung-Kee Kim, Seung Huh Division

More information

Abdominal and thoracic aneurysm repair

Abdominal and thoracic aneurysm repair Abdominal and thoracic aneurysm repair William A. Gray MD Director, Endovascular Intervention Cardiovascular Research Foundation Columbia University Medical Center Abdominal Aortic Aneurysm Endografts

More information

Anatomical challenges in EVAR

Anatomical challenges in EVAR Anatomical challenges in EVAR M.H. EL DESSOKI, MD,FRCS PROFESSOR OF VASCULAR SURGERY CAIRO UNIVERSITY Disclosure Speaker name:... I have the following potential conflicts of interest to report: Consulting

More information

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully Physician Training Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully supported by self-expanding z-stents H&L-B

More information

Access More Patients. Customize Each Seal.

Access More Patients. Customize Each Seal. Access More. Customize Each Seal. The Least Invasive Path Towards Proven Patency ULTRA LOW PROFILE TO EASE ADVANCEMENT The flexible, ultra-low 12F ID Ovation ix delivery system enables you to navigate

More information

Endovascular Treatment of the Aorta with Fenestrated and Branched Grafts

Endovascular Treatment of the Aorta with Fenestrated and Branched Grafts Endovascular Treatment of the Aorta with Fenestrated and Branched Grafts Eric LG Verhoeven,MD, PhD, A. Katsargyris, MD Vascular and Endovascular Surgery, Paracelsus Medical University, Nuremberg, Germany

More information

2015 Clinical Update Endovascular Systems for AAA Repair

2015 Clinical Update Endovascular Systems for AAA Repair Endovascular Systems for AAA Repair 2 Musick Irvine, CA 92618 Tel 949.595.7200 Fax 949.612.1893 www.endologix.com TABLE OF CONTENTS Section Page ABSTRACT... 3 READER S GUIDE... 4 SECTION 1: US PIVOTAL

More information

Chimney endovascular aneurysm sealing (ch-evas) for ruptured abdominal aortic aneurysms (AAA) due to type Ia endoleak following failed EVAS

Chimney endovascular aneurysm sealing (ch-evas) for ruptured abdominal aortic aneurysms (AAA) due to type Ia endoleak following failed EVAS Chimney endovascular aneurysm sealing (ch-evas) for ruptured abdominal aortic aneurysms (AAA) due to type Ia endoleak following failed EVAS Saritphat Orrapin MD FRCS (Thailand), Thoetphum Benyakorn, Tunyarat

More information

Now that Endoanchors are Approved (and paid for) We have a Durable Solution to Short Necks That s so Easy!

Now that Endoanchors are Approved (and paid for) We have a Durable Solution to Short Necks That s so Easy! Now that Endoanchors are Approved (and paid for) We have a Durable Solution to Short Necks That s so Easy! David H. Deaton, MD Vascular Surgery / University of South Carolina / Palmetto Health Chief Medical

More information

Hostile Neck During EVAR, The Role Of Endoanchores

Hostile Neck During EVAR, The Role Of Endoanchores Hostile Neck During EVAR, The Role Of Endoanchores Samer Koussayer, MD, FACS, RVT Prof, Al Faisal University Section Head and consultant Vascular & Endovascular Surgery Division King Faisal Specialist

More information

TriVascular Ovation Prime Abdominal Stent Graft System

TriVascular Ovation Prime Abdominal Stent Graft System TriVascular Ovation Prime Abdominal Stent Graft System Science of the Seal O-Ring Sealing Technology O-Ring Sealing in Proven Engineering Solutions O-rings are designed to seal by blocking the flow of

More information

Clinical trial and real-world outcomes of an endovascular iliac aneurysm repair with the GORE Iliac Branch Endoprosthesis (IBE)

Clinical trial and real-world outcomes of an endovascular iliac aneurysm repair with the GORE Iliac Branch Endoprosthesis (IBE) Clinical trial and real-world outcomes of an endovascular iliac aneurysm repair with the GORE Iliac Branch Endoprosthesis (IBE) Jan MM Heyligers, PhD, FEBVS Consultant Vascular Surgeon The Netherlands

More information

Disclosures. EVAR follow-up: actual recommendation. EVAR follow-up: critical issues

Disclosures. EVAR follow-up: actual recommendation. EVAR follow-up: critical issues Disclosures is it time to discuss individualized follow-up schemes based on preoperative anatomy and high quality completion angiography? Consultant / Speaker / Proctor Cook Cordis Medtronic Invatec W.L.

More information

Current Status of EVAR for Infrarenal AAA. 31 st Annual Florida Vascular Society. PENN Surgery

Current Status of EVAR for Infrarenal AAA. 31 st Annual Florida Vascular Society. PENN Surgery Current Status of EVAR for Infrarenal AAA 31 st Annual Florida Vascular Society PENN Surgery No Disclosures Stent Grafts Design Related Differences What really matters? Modular Unibody Supported Unsupported

More information

Analysis of Type IIIb Endoleaks Encountered with Endologix Endografts

Analysis of Type IIIb Endoleaks Encountered with Endologix Endografts Analysis of Type IIIb Endoleaks Encountered with Endologix Endografts Alan R. Wladis, MD, FACS, David Varnagy, MD, FACS, Manuel R. Perez-Izquierdo, MD, Mark Ranson, MD FACS, Delos Clift, MD FACS, Rebecca

More information

Cook Medical. Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training

Cook Medical. Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training Cook Medical Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full-thickness,

More information

Insights from the PROTAGORAS/PERICLES Registries: impact on ChEVAR results

Insights from the PROTAGORAS/PERICLES Registries: impact on ChEVAR results Insights from the PROTAGORAS/PERICLES Registries: impact on ChEVAR results Konstantinos P. Donas, Giovanni Torsello Department of Vascular Surgery St. Franziskus Hospital Münster, Germany Disclosure Speaker

More information

Challenging anatomies demand versatility.

Challenging anatomies demand versatility. Challenging anatomies demand versatility. The Distinct Advantages of Separating Seal and Fixation ANATOMICAL FIXATION Unlike proximal fixation designs, the AFX bifurcated unibody endograft allows for natural

More information

FROM THE EVERYDAY TO THE EXTRAORDINARY

FROM THE EVERYDAY TO THE EXTRAORDINARY FROM THE EVERYDAY TO THE EXTRAORDINARY Created with the collaboration of more than 250 physicians around the world, ENDURANT empowers you to create stronger outcomes for more patients, including those

More information

Mid-term results from ANCHOR: How does this data influence the treatment algorithm for hostile EVAR anatomies

Mid-term results from ANCHOR: How does this data influence the treatment algorithm for hostile EVAR anatomies Mid-term results from ANCHOR: How does this data influence the treatment algorithm for hostile EVAR anatomies Jean-Paul P.M. de Vries Head Department of Surgery, University Medical Centre Groningen The

More information

Endoanchor-assisted TEVAR

Endoanchor-assisted TEVAR Endoanchor-assisted TEVAR May 29, 2015 NCVH2015 Grayson H. Wheatley III, MD Director of Aortic and Endovascular Surgery Associate Professor of Surgery Temple University School of Medicine Disclosures Consultant

More information

GORE EXCLUDER AAA Endoprosthesis ANNUAL CLINICAL UPDATE OCTOBER Section I Clinical experience. Section II Worldwide commercial experience

GORE EXCLUDER AAA Endoprosthesis ANNUAL CLINICAL UPDATE OCTOBER Section I Clinical experience. Section II Worldwide commercial experience GORE EXCLUDER AAA Endoprosthesis ANNUAL CLINICAL UPDATE OCTOBER 2018 Abstract This annual clinical update provides a review of the ongoing experience with the GORE EXCLUDER AAA Endoprosthesis used in the

More information

EVAS Sealing Technology: The new paradigm in AAA therapy

EVAS Sealing Technology: The new paradigm in AAA therapy June 2016 EDUCATIONAL SUPPLEMENT EVAS Sealing Technology: The new paradigm in AAA therapy This educational supplement has been supported by an unrestricted educational grant from Endologix MM1398 Rev 01

More information

ChEVAR Vs. fevar for juxtarenal Aneurysm. E.Ducasse MD PhD FEVBS Unit of vascular surgery CHU bordeaux

ChEVAR Vs. fevar for juxtarenal Aneurysm. E.Ducasse MD PhD FEVBS Unit of vascular surgery CHU bordeaux ChEVAR Vs. fevar for juxtarenal Aneurysm E.Ducasse MD PhD FEVBS Unit of vascular surgery CHU bordeaux CH-EVAR VS. F-EVAR IN JAAAs Meta-analysis, 2001-2012 5 CH-EVAR studies (94 patients, 151 target vessels)

More information

Case Report A Case of Successful Coil Embolization for a Late-Onset Type Ia Endoleak after Endovascular Aneurysm Repair with the Chimney Technique

Case Report A Case of Successful Coil Embolization for a Late-Onset Type Ia Endoleak after Endovascular Aneurysm Repair with the Chimney Technique Case Reports in Vascular Medicine Volume 2016, Article ID 5307416, 4 pages http://dx.doi.org/10.1155/2016/5307416 Case Report A Case of Successful Coil Embolization for a Late-Onset Type Ia Endoleak after

More information

Low profile TEVAR: is it an added value? Michel Bosiers, G. Torsello Münster

Low profile TEVAR: is it an added value? Michel Bosiers, G. Torsello Münster Low profile TEVAR: is it an added value? Michel Bosiers, G. Torsello Münster Disclosure Speaker name:...michel Bosiers... I have the following potential conflicts of interest to report: Consulting Employment

More information

Why Nellix? Treating Concomitant Common Iliac Aneurysms

Why Nellix? Treating Concomitant Common Iliac Aneurysms INDICATIONS FOR USE The Nellix EndoVascular Aneurysm Sealing System can be used in patients who have an infrarenal abdominal aortic (AAA) or aortoiliac aneurysm with suitable anatomy as indicated below:

More information

MODERN METHODS FOR TREATING ABDOMINAL ANEURYSMS AND THORACIC AORTIC DISEASE

MODERN METHODS FOR TREATING ABDOMINAL ANEURYSMS AND THORACIC AORTIC DISEASE MODERN METHODS FOR TREATING ABDOMINAL ANEURYSMS AND THORACIC AORTIC DISEASE AAA FACTS 200,000 New Cases Each Year Ruptured AAA = 15,000 Deaths per Year in U.S. 13th Leading Cause of Death 80% Chance of

More information

Fenestrated Implantation: How I do it. Tara M Mastracci, FRCSC, FACS, FRCS, MSc Royal Free London

Fenestrated Implantation: How I do it. Tara M Mastracci, FRCSC, FACS, FRCS, MSc Royal Free London Fenestrated Implantation: How I do it. Tara M Mastracci, FRCSC, FACS, FRCS, MSc Royal Free London Disclosures Cook Medical Inc -- Proctorship and Consultation All speaking and consultation fees are donated

More information

From 1996 to 1999, a total of 1,193 patients with

From 1996 to 1999, a total of 1,193 patients with THE ANEURX CLINICAL TRIAL AT 8 YEARS Lessons learned following the US AneuRx clinical trial from 1996 to 2004. BY CHRISTOPHER K. ZARINS, MD From 1996 to 1999, a total of 1,193 patients with infrarenal

More information

EVAS How does this Impact EVAR Therapy

EVAS How does this Impact EVAR Therapy EVAS How does this Impact EVAR Therapy John S. Lane III, MD, FACS Professor and Acting Chief of Vascular Surgery University of California, San Diego PNEC, 2017 Endologix products and associated components

More information

Degeneration of the Neck Post Implementation - a New Era of AAA Stent

Degeneration of the Neck Post Implementation - a New Era of AAA Stent Degeneration of the Neck Post Implementation - a New Era of AAA Stent New Mexico Heart Institute Albuquerque, New Mexico USA - Gore Current FDA-Approved EVAR Devices Sealing Mechanism Endologix Lombard

More information

COMBINED TECHNIQUE CHIMNEY + FENESTRATED ENDOGRAFT FOR COMPLEX ANEURYSMS ERIC DUCASSE - MD PHD FEVBS CHU BORDEAUX

COMBINED TECHNIQUE CHIMNEY + FENESTRATED ENDOGRAFT FOR COMPLEX ANEURYSMS ERIC DUCASSE - MD PHD FEVBS CHU BORDEAUX COMBINED TECHNIQUE CHIMNEY + FENESTRATED ENDOGRAFT FOR COMPLEX ANEURYSMS ERIC DUCASSE - MD PHD FEVBS CHU BORDEAUX DISCLOSURE SPEAKER NAME: PR. E. DUCASSE I HAVE THE FOLLOWING POTENTIAL CONFLICTS OF INTEREST

More information

EVAR Revision Setting - How can Heli-FX EndoAnchors improve the outcomes?

EVAR Revision Setting - How can Heli-FX EndoAnchors improve the outcomes? D. Böckler Department of Vascular and Endovascular Surgery University Hospital Heidelberg EVAR Revision Setting - How can Heli-FX EndoAnchors improve the outcomes? Disclosures Speaker name: Dittmar Böckler

More information

Important Update to Field Safety Notice Nellix EndoVascular Aneurysm Sealing System Updated Instructions for Use (IFU)

Important Update to Field Safety Notice Nellix EndoVascular Aneurysm Sealing System Updated Instructions for Use (IFU) October 6, 2017 Important Update to Field Safety Notice Nellix EndoVascular Aneurysm Sealing System Updated Instructions for Use (IFU) Dear Physician, This notification is to provide you with further information

More information

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up Zenith Renu AAA Converter Graft Device Description Planning and Sizing Deployment Sequence Patient Follow-Up Device description: Device indications The Zenith Renu AAA Converter Graft with Z-Trak Introduction

More information

Right Choice for Right Angles

Right Choice for Right Angles Right Choice for Right Angles The Anatomy of Technology Aorfix gives you technology that conforms to patient anatomy, optimising both procedure and post-operative performance. Fishmouth for optimum neck

More information

Dr Peter Bungay Derbyshire Vascular Services Royal Derby Hospital Derby UK

Dr Peter Bungay Derbyshire Vascular Services Royal Derby Hospital Derby UK Dr Peter Bungay Derbyshire Vascular Services Royal Derby Hospital Derby UK Disclosure I have the following potential conflicts of interest to report Consultant, proctor and paid speaker for Vascutek UK

More information

Standardization of the CHEVAR procedure: How a standard approach has improved outcomes. Prof Peter Holt St George s, London

Standardization of the CHEVAR procedure: How a standard approach has improved outcomes. Prof Peter Holt St George s, London Standardization of the CHEVAR procedure: How a standard approach has improved outcomes Prof Peter Holt St George s, London Disclosure Speaker name: Prof Peter Holt I have the following potential conflicts

More information

Predictors of abdominal aortic aneurysm sac enlargement after EVAR Longterm results from the ENGAGE Registry

Predictors of abdominal aortic aneurysm sac enlargement after EVAR Longterm results from the ENGAGE Registry Predictors of abdominal aortic aneurysm sac enlargement after EVAR Longterm results from the ENGAGE Registry D. Böckler Department of Vascular and Endovascular Surgery University Hospital Heidelberg Disclosure

More information

Current Status of Abdominal Aortic Stent Grafts. John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center

Current Status of Abdominal Aortic Stent Grafts. John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center Current Status of Abdominal Aortic Stent Grafts John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center Autumn Greetings Disclosure Statement of Financial Interest Within

More information

FLEXIBLE, BALOON EXPANDABLE

FLEXIBLE, BALOON EXPANDABLE EARLY RESULTS OF A CLINICAL TRIAL OF FLEXIBLE, BALOON EXPANDABLE COVERED STENT GRAFT IN ILIAC OCCLUSIVE DISEASE Chris LeCroy Coastal Vascular and Interventional Pensacola, Florida Clinical Trial WL GORE

More information

Prospective, multicenter experience with the Ventana Fenestrated System for juxtarenal and pararenal aortic aneurysm endovascular repair

Prospective, multicenter experience with the Ventana Fenestrated System for juxtarenal and pararenal aortic aneurysm endovascular repair From the Western Vascular Society CLINICAL RESEARCH STUDIES Prospective, multicenter experience with the Ventana Fenestrated System for juxtarenal and pararenal aortic aneurysm endovascular repair William

More information

Durable outcomes. Proven performance.

Durable outcomes. Proven performance. Durable outcomes. Proven performance. GORE EXCLUDER AAA Endoprosthesis GORE EXCLUDER Iliac Branch Endoprosthesis GORE EXCLUDER AAA Endoprosthesis The most-studied* EVAR stent graft designed for durable

More information

Three year experience with multilayer stent in the treatment of thoracoabdominal aneurysms no evidence for aneurysm stabilization

Three year experience with multilayer stent in the treatment of thoracoabdominal aneurysms no evidence for aneurysm stabilization Three year experience with multilayer stent in the treatment of thoracoabdominal aneurysms no evidence for aneurysm stabilization Thomas Larzon, MD, PhD Head of Vascular Surgery Dept of Cardiothoracic

More information

Trattamento Endovascolare degli Aneurismi dell Aorta Addominale con Colletto Prossimale Ostile:

Trattamento Endovascolare degli Aneurismi dell Aorta Addominale con Colletto Prossimale Ostile: Trattamento Endovascolare degli Aneurismi dell Aorta Addominale con Colletto Prossimale Ostile: Risultati Precoci e a Medio Termine in Esperienza Monocentrica A.Lauricella - R.Silingardi Chirurgia Vascolare,

More information

Ancillary Components with Z-Trak Introduction System

Ancillary Components with Z-Trak Introduction System Ancillary Components with Z-Trak Introduction System Zenith Flex AAA Endovascular Graft Ancillary Components Converter Converters can be used to convert a bifurcated graft into an aortouniiliac graft if

More information

Endoleaks after F-BEVAR How to Assess & Treat? Gustavo S. Oderich, MD Mayo Clinic Rochester, MN

Endoleaks after F-BEVAR How to Assess & Treat? Gustavo S. Oderich, MD Mayo Clinic Rochester, MN Endoleaks after F-BEVAR How to Assess & Treat? Gustavo S. Oderich, MD Mayo Clinic Rochester, MN FACULTY DISCLOSURE Gustavo S. Oderich MD Consulting, DSMB, CEC* Cook Medical Inc., WL Gore, Lombardi Honoraria

More information

Redo treatment and open conversion after TEVAR

Redo treatment and open conversion after TEVAR Redo treatment and open conversion after TEVAR Roberto Chiesa Vascular Surgery, Vita-Salute University Scientific Institute San Raffaele Milan, Italy Number of procedures Off-Label indications for TEVAR

More information

Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment

Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment Robert Y. Rhee, MD Chief, Vascular and Endovascular Surgery Director, Aortic Center Maimonides Medical Center Brooklyn,

More information

12-year Experience with the Endologix Powerlink R Device in Endovascular Repair of Abdominal Aortic Aneurysms

12-year Experience with the Endologix Powerlink R Device in Endovascular Repair of Abdominal Aortic Aneurysms 11 12-year Experience with the Endologix Powerlink R Device in Endovascular Repair of Abdominal Aortic Aneurysms Ziheng Wu 1, Lefeng Qu 2, Dieter Raithel 3 and Konstantinos Xiromeritis³ 1 Department of

More information

Is EVAS a proper choice in women?

Is EVAS a proper choice in women? Is EVAS a proper choice in women? CACVS 2018 Jan MM Heyligers, PhD, FEBVS Consultant Vascular Surgeon Elisabeth TweeSteden Hospital Tilburg The Netherlands Disclosures Consultant for Endologix DEVASS =Dutch

More information

Treatment of Thoracoabdominal Aneurysms Is there a need for custom-made devices?

Treatment of Thoracoabdominal Aneurysms Is there a need for custom-made devices? : FETURED TECHNOLOGY: JOTEC E-XTR DESIGN ENGINEERING Treatment of Thoracoabdominal neurysms Is there a need for custom-made devices? INTERVIEW ND CSE PRESENTTIONS WITH DNIEL RNZN, MD, ND NDREJ SCHMIDT,

More information

Combined Endovascular and Surgical Repair of Thoracoabdominal Aortic Pathology: Hybrid TEVAR

Combined Endovascular and Surgical Repair of Thoracoabdominal Aortic Pathology: Hybrid TEVAR Combined Endovascular and Surgical Repair of Thoracoabdominal Aortic Pathology: Hybrid TEVAR William J. Quinones-Baldrich MD Professor of Surgery Director UCLA Aortic Center UCLA Medical Center Los Angeles,

More information

Taming The Aorta. David Minion, MD Program Director, Vascular Surgery University of Kentucky Medical Center Lexington, Kentucky, USA

Taming The Aorta. David Minion, MD Program Director, Vascular Surgery University of Kentucky Medical Center Lexington, Kentucky, USA Taming The Aorta David Minion, MD Program Director, Vascular Surgery University of Kentucky Medical Center Lexington, Kentucky, USA Faculty Disclosure Consulting: Endologix, Cook 1 Objectives Review the

More information