HxSil C18, 4.6 x 150mm, 5um (P/N 79868) 1. Oxybenzone 2. Octocrylene 3. Octyl Methoxycinnamate 4. Avobenzone (Parsol 1789) 5.

Size: px
Start display at page:

Download "HxSil C18, 4.6 x 150mm, 5um (P/N 79868) 1. Oxybenzone 2. Octocrylene 3. Octyl Methoxycinnamate 4. Avobenzone (Parsol 1789) 5."

Transcription

1 Page 1 of 5 U S A HPLC Application Index Ordering Information Contact HPLC Support Silica-based columns for general separations: Separation of closely related PAH's Better retention of poorly retained compounds Separation of neutral, acidic and basic compounds without tailing (tailing factor of less than 2.0). Product Features Two particle sizes: 3, 5, 7, 10 and 12-20um. Five column internal diameters: 2.1 to 21.5 mm. Analytical and semiprep/preparative guard columns in 316 stainless steel. What Types of Samples Can HxSil C8, C18 Columns Separate? Sunscreens in Lip Balm 1. Oxybenzone 2. Octocrylene 3. Octyl Methoxycinnamate 4. Avobenzone (Parsol 1789) 5. Octyl Salicylate Conditions: 85:15 Methanol : Water. Injection: 5 µl Detection: UV at 308nm. Sunscreen Compounds 1. 2-Hydroxy-4-methoxybenzophenone 2. 2-Ethylhexyl trans-4-methoxycinnamate 3. 2-Ethylhexylsalicylate Conditions:7:1 Acetonitrile : Water. Injection: 10µL Detection: UV at 254nm. Diphenhydramine in Itch Relief Gel 1. Diphenhydramine 10ppm Conditions:9:1 Methanol : 20mM Potassium Hydrogen Phosphate ph 7.0. Injection: 5µL Detection: UV at 254nm.

2 Page 2 of 5 Diphenhydramine in Itch Relief Gel In Figure 11 the antihistamine diphenhydramine is separated from other components present in the gel in just over 2 minutes. Easy sample preparation is characterized by water dilution, and filtration. The compound of interest (diphenhydramine) is an amine base. Meclizine in Pills 1. Meclizine 1mg/mL Conditions: 9:1 Methanol : 20mM Potassium Hydrogen Phosphate ph 7.0. Isocratic.

3 Page 3 of 5 Meclizine in Motion Sickness Pills The antiemetic, meclizine is separated from excipients in the motion sickness pills. This amine base drug exhibits excellent symmetry (Tailing Factor of 1.061) on a Hamilton HxSil C-18 column. Tetracycline by USP Method HxSil C18, 4.6 x 250mm, 5um (P/N 79869) 1. Tetracycline 0.5mg/mL Conditions: 680mL 0.1N Ammonium Oxalate, 270mL Dimethylformamide, 50mL 0.2M Dibasic Ammonium Phosphate ph 7.6. Injection: 10 µl Detection: UV at 280 nm USP Methods The Hamilton HxSil C-18 column meets the requirements of a USP L1 column and the HxSil C-8 column meets the requirements for an L7 column. The application above illustrates the analysis of tetracycline and the two applications below demonstrate the separation of oxytetracycline and tetracycline using a HxSil C-8 "L7" column and folic acid from methotrexate on a HxSil C-18 "L1" column. Oxytetracycline and Tetracycline HxSil C8, 4.6 x 150mm, 5um (P/N 79102) 1. Oxytetracycline 0.5mg/mL 2. Tetracycline 0.5mg/mL Conditions: 680mL 0.1N Ammonium Oxalate, 270mL Dimethylformamide, 50mL 0.2 M Dibasic Ammonium Phosphate ph 7.6. Injection: 20 ul Detection: UV at 280nm. Folic Acid and Methotrexate by USP Method 1. Folic Acid 100ug/mL 2. Methotrexate 100ug/mL Conditions: 9: M Sodium Phosphate, Dibasic, 0.037M Citric Acid ph 6.0 : Acetonitrile. Isocratic. Flow: 1.2 ml/min. Injection: 10 µl

4 Page 4 of 5 Detection: UV at 302nm. Antibiotics HxSil C8, 4.6 x 150mm (P/N 79102) 1.. Ampicillin 2. Oxacillin 3. Dicloxacillin Conditions: 3:1 0.05M Potassium Phosphate ph 7 : Acetonitrile. Isocratic. Injection: 5µL Small Molecules 1. Uracil 10ppm 2. Caffeine 10ppm 3. Phenol 10ppm 4. Toluene 10ppm 5. Butylbenzene 100ppm 6. Triphenylene 10ppm 7. Amylbenzene 100ppm 8. Terphenyl 10ppm Conditions: 7:3 Acetonitrile : Water. Injection: 50 µl

5 Page 5 of 5 ORDERING INFORMATION HxSil C8 Reversed Phase HPLC Columns C8 C18 I.D. x Length 3 µm 5 µm 3µm 5 µm 2.1 x 33 mm x 50 mm x 75mm x 100mm x 150 mm x 33 mm x 50 mm x 100 mm x 150 mm x 250 mm x 250 mm x 250 mm x 250 mm HxSil C8, C18 Guard Columns C8 C18 Analytical Starter Kits (1 holder, 2 cartridges) Analytical Replacement Cartridges (5/pk) Semiprep/Preparative Starter Kit (1 holder, 1 cartridge) Semiprep/Preparative Replacement Cartridges (2/pk) Guard Column Technical Information Column Care and Storage About Hamilton Contact Quick Order Service News & Promos Copyright Hamilton Company. All Rights Reserved. Terms of Use. Privacy Statement.

HC-75 Calcium Form. 305 x 7.8 mm HC-75 Calcium Form (P/N 79436)

HC-75 Calcium Form. 305 x 7.8 mm HC-75 Calcium Form (P/N 79436) Page 1 of 5 U S A Example Applications HPLC Application Index Ordering Information Contact HPLC Support Polymeric cross-linked soft-gel columns for cation, ligand exchange separation of carbohydrates:

More information

InertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior

InertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior InertSustain Phenylhexyl A ew Second Choice Column to Change Chromatographic Behavior Providing Alternative Selectivity to C8 Phases InertSustain Phenylhexyl columns are bonded with phenylhexyl groups,

More information

Analytical and Preparative SFC Columns

Analytical and Preparative SFC Columns Analytical and Preparative SFC Columns Best Performance for Supercritical Fluid Chromatography Sepax SFC-Cyano... Sepax SFC-Amino... Sepax SFC-Pyridine... Sepax SFC-SCX... 5 Sepax SFC-Diol... 6 Sepax SFC-Silica...

More information

Sepax Technologies, Inc.

Sepax Technologies, Inc. Sepax Technologies, Inc. Sepax Technologies, Inc. develops and manufactures products in the area of chemical and biological separations, biosurfaces and proteomics. Sepax product portfolio includes ) liquid

More information

A New Dimension in Preparative HPLC

A New Dimension in Preparative HPLC New Dimension in Preparative HPL... we Meet your Needs NULEODUR HTec 6 - key features: reliable and durable standard RP phase for up-scaling to preparative scale, suited for L/MS high loadability and excellent

More information

HPLC Column for Structural Isomers COSMOSIL Cholester

HPLC Column for Structural Isomers COSMOSIL Cholester HPLC Column for Structural Isomers COSMOSIL ol bonded stationary phase Increased stereoselectivity Improved resolution for geometric isomers Silica Gel Average Particle Size Average Pore Size Stationary

More information

RITONAVIRI COMPRESSI RITONAVIR TABLETS. Final text for addition to The International Pharmacopoeia (July 2012)

RITONAVIRI COMPRESSI RITONAVIR TABLETS. Final text for addition to The International Pharmacopoeia (July 2012) July 2012 RITONAVIRI COMPRESSI RITONAVIR TABLETS Final text for addition to The International Pharmacopoeia (July 2012) This monograph was adopted at the Forty-sixth WHO Expert Committee on Specifications

More information

TENOFOVIR TABLETS: Final text for addition to The International Pharmacopoeia (June 2010)

TENOFOVIR TABLETS: Final text for addition to The International Pharmacopoeia (June 2010) June 2010 TENOFOVIR TABLETS: Final text for addition to The International Pharmacopoeia (June 2010) This monograph was adopted at the Forty-fourth WHO Expert Committee on Specifications for Pharmaceutical

More information

Tenofovir disoproxil fumarate (Tenofoviri disoproxili fumaras)

Tenofovir disoproxil fumarate (Tenofoviri disoproxili fumaras) C 19 H 30 N 5 O 10 P. C 4 H 4 O 4 Relative molecular mass. 635.5. Chemical names. bis(1-methylethyl) 5-{[(1R)-2-(6-amino-9H-purin-9-yl)-1-methylethoxy]methyl}-5-oxo-2,4,6,8-tetraoxa-5-λ 5 - phosphanonanedioate

More information

Extended Application Note

Extended Application Note Extended Application Note Comparison of 4 μm vs. 2.o Columns in Analysis of Drospirenone/Ethinyl Estradiol Tablet APP A-339 www.mtc-usa.com 1-732-578-1777 INTRODUCTION The formulation of drospirenone and

More information

Roc On with These Dependable LC Columns

Roc On with These Dependable LC Columns Roc LC s Conventional column built to be the cornerstone for your lab; pressure rated for any 400 bar system. Solid and reliable delivers the peak shape, reproducibility, ruggedness, and performance you

More information

USP Method Transfer of Ziprasidone HCl from HPLC to UPLC

USP Method Transfer of Ziprasidone HCl from HPLC to UPLC Mia Summers and Kenneth J. Fountain Waters Corporation, Milford, MA, USA APPLICATION BENEFITS Updating USP Methods from HPLC to UPLC using sub-2 µm columns 85% decrease in analysis time, faster throughput

More information

Quetiapine Tablets. Expert Committee Monographs Chemical Medicines 4 Reason for Revision Compliance

Quetiapine Tablets. Expert Committee Monographs Chemical Medicines 4 Reason for Revision Compliance Quetiapine Tablets Type of Posting Revision Bulletin Posting Date 25 Sep 2015 Official Date 01 Nov 2015 Expert Committee Monographs Chemical Medicines 4 Reason for Revision Compliance In accordance with

More information

C30 ISOMERS HAVE MET THEIR MATCH

C30 ISOMERS HAVE MET THEIR MATCH C30 ISOMERS HAVE MET THEIR MATCH INTRODUCING THE NEW! Built on proven Fused-Core particle technology, the is designed to deliver fast separations ideal for lipids and isomers compared to your C18. FEATURES

More information

Revision Bulletin 23 Feb Mar 2018 Chemical Medicines Monographs 3 Compliance

Revision Bulletin 23 Feb Mar 2018 Chemical Medicines Monographs 3 Compliance Esomeprazole Magnesium Delayed-Release Capsules Type of Posting Posting Date Official Date Expert Committee Reason for Revision Revision Bulletin 23 Feb 2018 01 Mar 2018 Chemical Medicines Monographs 3

More information

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1 APPLICATIONS A Comparison of Various Kinetex C18 Phases Zeshan Aqeel and Jeff Layne Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA Introduction When performing reversed phase LC separations, there

More information

Telmisartan and Hydrochlorothiazide Tablets. Type of Posting. Revision Bulletin Posting Date. 26 Jan 2018 Official Date

Telmisartan and Hydrochlorothiazide Tablets. Type of Posting. Revision Bulletin Posting Date. 26 Jan 2018 Official Date Telmisartan and Hydrochlorothiazide Tablets Type of Posting Revision Bulletin Posting Date 26 Jan 2018 Official Date 01 Feb 2018 Expert Committee Chemical Medicines Monographs 2 Reason for Revision Compliance

More information

Should you have any questions, please contact Gerald Hsu, Ph.D., Senior Scientific Liaison ( or

Should you have any questions, please contact Gerald Hsu, Ph.D., Senior Scientific Liaison ( or Estradiol Transdermal System Type of Posting Revision Bulletin Posting Date 27 Jan 2017 Official Date 01 Feb 2017 Expert Committee Chemical Medicines Monographs 5 Reason for Revision Compliance In accordance

More information

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix Application Note Separation of clindamycin phosphate and process impurities Category Pharmaceutical analysis Matrix Drugs Method UHPLC Keywords Antibiotics, process impurities, quality control Analytes

More information

SeQuant ZIC -HILIC For all who expect more...

SeQuant ZIC -HILIC For all who expect more... SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany Poor

More information

SeQuant ZIC -HILIC For all who expect more...

SeQuant ZIC -HILIC For all who expect more... SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore is a division of Merck KGaA, Darmstadt, Germany Poor retention

More information

Systematic Evaluation of Solid Phase Extraction (SPE) Chemistries for the Determination of Acidic, Neutral, and Basic Drugs

Systematic Evaluation of Solid Phase Extraction (SPE) Chemistries for the Determination of Acidic, Neutral, and Basic Drugs Systematic Evaluation of Solid Phase Extraction (SPE) Chemistries for the Determination of Acidic, Neutral, and Basic Drugs Laura Marlatt, An Trinh, and David S. Bell Supelco, 595 North Harrison Road,

More information

Ultra Columns HPLC COLUMNS

Ultra Columns HPLC COLUMNS Acetaminophen, Narcotic Analgesics.............519 Aldehydes, Ketones...........................500 Beclomethasone.............................523 Corticosteroids..............................529 Explosives..................................501

More information

Am I getting the very best value from my UHPLC analyses?

Am I getting the very best value from my UHPLC analyses? Am I getting the very best value from my UHPLC analyses? Stephen Luke LC Columns Product Manager 1 Primary reasons for UHPLC use Very fast Very high resolution Column 2.1 x 50 mm Column 2.1 x 150 mm Run

More information

Title Revision n date

Title Revision n date A. THIN LAYER CHROMATOGRAPHIC TECHNIQUE (TLC) 1. SCOPE The method describes the identification of hydrocortisone acetate, dexamethasone, betamethasone, betamethasone 17-valerate and triamcinolone acetonide

More information

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography Application ote Food Safety Authors Chen-Hao Zhai and Yun Zou Agilent Technologies Co. Ltd.

More information

Column Stability and Performance under High Temperature HPLC Conditions

Column Stability and Performance under High Temperature HPLC Conditions Column Stability and Performance under High Temperature HPLC Conditions Stephanie J. Marin Brian Jones, Dale Felix, Jody Clark Selerity Technologies, Inc. Salt Lake City, UT www.selerity.com Introduction

More information

176 YMC Chiral Columns

176 YMC Chiral Columns 176 YMC Chiral Columns YMC Chiral Columns 177 Chiral Columns Content YMC Chiral NEA(R)(S)... 178-181 YMC Chiral CD BR... 182-185 Ordering Information... 186 HPLC Columns for Optical Isomer Separation Introduction

More information

Ultra Columns. also available. ordering note

Ultra Columns. also available. ordering note : 3μm or 5μm particles; 100Å pore size Our broadest selection of stationary phases, including unique phases. High density bondings, for maximum retention. High-purity, Type B silica gives excellent peak

More information

Eurospher II the logical choice. Physical properties of Eurospher II silica gel: Silica gel: ultra pure, > % Metal content: < 10 ppm

Eurospher II the logical choice. Physical properties of Eurospher II silica gel: Silica gel: ultra pure, > % Metal content: < 10 ppm HPLC SMB smometry Euroline Eurospher II Eurospher II the logical choice After more than years on the market, our Eurospher stationary phase has established a reputation for being a first-class packing

More information

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE Aeris Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations Aeris is a specialized line of reversed phase core-shell UHPLC columns, built exclusively for the ultra-high performance

More information

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column Application Note Pharmaceutical and Food Testing Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column Author Lu Yufei Agilent Technologies, Inc. Abstract A liquid chromatographic

More information

ARTESUNATE TABLETS: Final text for revision of The International Pharmacopoeia (December 2009) ARTESUNATI COMPRESSI ARTESUNATE TABLETS

ARTESUNATE TABLETS: Final text for revision of The International Pharmacopoeia (December 2009) ARTESUNATI COMPRESSI ARTESUNATE TABLETS December 2009 ARTESUNATE TABLETS: Final text for revision of The International Pharmacopoeia (December 2009) This monograph was adopted at the Forty-fourth WHO Expert Committee on Specifications for Pharmaceutical

More information

LC Columns with Liquid Separation Cell Technology

LC Columns with Liquid Separation Cell Technology Obelisc LC Columns with Liquid Separation Cell Technology Obelisc HPLC Columns - Liquid Separation Cell Technology Introduction Obelisc HPLC columns are the latest, innovative columns from SIELC Technologies,

More information

Revision Bulletin 28 Jul Aug 2017 Chemical Medicines Monographs 3

Revision Bulletin 28 Jul Aug 2017 Chemical Medicines Monographs 3 Oxybutynin Chloride Extended-Release Tablets Type of Posting Posting Date Official Date Expert Committee Reason for Revision Revision Bulletin 28 Jul 2017 01 Aug 2017 Chemical Medicines Monographs 3 Compliance

More information

Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016.

Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016. Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016 Aspartame This monograph was also published in: Compendium of Food Additive

More information

Should you have any questions, please contact Heather Joyce, Ph.D., Senior Scientific Liaison ( or

Should you have any questions, please contact Heather Joyce, Ph.D., Senior Scientific Liaison ( or Divalproex Sodium Delayed-Release Capsules Type of Posting Revision Bulletin Posting Date 29 July 2016 Official Date 01 Aug 2016 Expert Committee Chemical Medicines Monographs 4 Reason for Revision Compliance

More information

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined ProteCol LC Columns - Exceed the limit A premium inert range of LC columns delivering optimal peak shape. ProteCol -G Glass lined ProteCol -P PEEK lined B C A D E F A Column end cap B PEEK frit housing

More information

A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide in Bulk and Pharmaceutical Dosage Forms

A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide in Bulk and Pharmaceutical Dosage Forms OPEN ACCESS Eurasian Journal of Analytical Chemistry ISSN: 1306-3057 2017 12(2):31-44 DOI 10.12973/ejac.2017.00152a A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide

More information

Reversed-Phase Columns (Other than ODS)

Reversed-Phase Columns (Other than ODS) 7 Reversed-Phase Columns (ther than DS) Types and characteristics of reversed-phase columns -- 9, 9 YMC-Pack Pro C8, C--------------------------- 96 YMC-Pack C 8 --------------------------------------

More information

VertiSep TM PRP. HPLC Columns. VertiSep TM PRP HPLC Columns

VertiSep TM PRP. HPLC Columns. VertiSep TM PRP HPLC Columns VertiSep TM PRP ph stable range 1-14 Excellent analyte recovery Very rugged, long lasting materials Great peak shape for all types on compounds Good reproducibility from column to column VertiSep TM PRP-L21

More information

This revision also necessitates a change in the table numbering in the test for Organic Impurities.

This revision also necessitates a change in the table numbering in the test for Organic Impurities. Methylphenidate Hydrochloride Extended-Release Tablets Type of Posting Notice of Intent to Revise Posting Date 27 Jul 2018 Targeted Official Date To Be Determined, Revision Bulletin Expert Committee Chemical

More information

Normal Phase HPLC Column COSMOSIL SL-II

Normal Phase HPLC Column COSMOSIL SL-II Normal Phase HPLC Column COSMOSIL SL-II High purity silica gel (>99.99%) with special treatment Suitable for preparative separation Ultra-pure silica gel of more than 99.99% purity is used for the COSMOSIL

More information

CYCLOSERINI CAPSULAE - CYCLOSERINE CAPSULES (AUGUST 2015)

CYCLOSERINI CAPSULAE - CYCLOSERINE CAPSULES (AUGUST 2015) August 2015 Document for comment 1 2 3 4 5 CYCLOSERINI CAPSULAE - CYCLOSERINE CAPSULES DRAFT PROPOSAL FOR THE INTERNATIONAL PHARMACOPOEIA (AUGUST 2015) DRAFT FOR COMMENT 6 Should you have any comments

More information

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency

More information

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis X. Liu, C. Pohl, Dionex Corporation, Sunnyvale, CA, USA ABSTRACT Although reversed-phase (RP) silica columns (e.g., C18 and

More information

Agilent Technologies Prep LC Columns

Agilent Technologies Prep LC Columns Agilent Technologies Prep LC Columns Agilent Technologies Prep LC Columns Agilent Technologies has always taken seriously its responsibility to ensure your success. That s why all our instruments and supplies

More information

GlycanPac AXH-1 Columns

GlycanPac AXH-1 Columns Thermo Scientific GlycanPac AXH-1 Columns Product Manual P/N: 065479-01 January 2013 Part of Thermo Fisher Scientific Product Manual for GlycanPac AXH-1 Columns GlycanPac AXH-1, 1.9 µm, Analytical, 2.1

More information

contents of the currently official monograph. Please refer to the current edition of the USP NF for official text.

contents of the currently official monograph. Please refer to the current edition of the USP NF for official text. Diltiazem Hydrochloride Extended-Release Capsules Type of Posting Notice of Intent to Revise Posting Date 25 May 2018 Targeted Official Date To Be Determined, Revision Bulletin Expert Committee Chemical

More information

Isocratic Reversed Phase Liquid Chromatographic Method Validation for the Determination of Cilostazol in Pure and Formulations

Isocratic Reversed Phase Liquid Chromatographic Method Validation for the Determination of Cilostazol in Pure and Formulations Human Journals Research Article October 2015 Vol.:4, Issue:3 All rights are reserved by Rambabu K et al. Isocratic Reversed Phase Liquid Chromatographic Method Validation for the Determination of Cilostazol

More information

HPLC to UHPLC Transfer of USP Method for Amlodipine Besylate Using the Agilent 1290 Infinity II LC

HPLC to UHPLC Transfer of USP Method for Amlodipine Besylate Using the Agilent 1290 Infinity II LC HPLC to UHPLC Transfer of USP Method for Amlodipine Besylate Using the Agilent 129 Infinity II LC Application Note Small Molecule Pharmaceuticals Authors Gerd Vanhoenacker, Mieke Steenbeke, Koen Sandra,

More information

The LC Column Playbook

The LC Column Playbook The LC Column Playbook Mark Powell Applications Engineer Technical Support 1 Overview How do we achieve our goal: Resolution? Efficiency Particle size Column length Selectivity Bonded phase Mobile phase

More information

Diltiazem Hydrochloride Extended-Release Capsules. Type of Posting Posting Date Official Date

Diltiazem Hydrochloride Extended-Release Capsules. Type of Posting Posting Date Official Date Diltiazem Hydrochloride Extended-Release Capsules Type of Posting Posting Date Official Date Revision Bulletin 17 Nov 2017 01 Dec 2017 Expert Committee Chemical Medicines Monographs 2 Reason for Revision

More information

Continuation of Reversed-Phase HPLC Analysis Studies of Steviol Glycosides Isolated From Stevia rebaudiana Bertoni

Continuation of Reversed-Phase HPLC Analysis Studies of Steviol Glycosides Isolated From Stevia rebaudiana Bertoni Journal of Food Research; Vol. 4, No. 2; 2015 ISSN 1927-0887 E-ISSN 1927-0895 Published by Canadian Center of Science and Education Continuation of Reversed-Phase HPLC Analysis Studies of Steviol Glycosides

More information

ZIDOVUDINE, LAMIVUDINE AND ABACAVIR TABLETS Draft proposal for The International Pharmacopoeia (September 2006)

ZIDOVUDINE, LAMIVUDINE AND ABACAVIR TABLETS Draft proposal for The International Pharmacopoeia (September 2006) September 2006 RESTRICTED ZIDOVUDINE, LAMIVUDINE AND ABACAVIR TABLETS Draft proposal for The International Pharmacopoeia (September 2006) This document was provided by a contracted quality control laboratory.

More information

Choosing Preparative Columns

Choosing Preparative Columns Choosing Preparative Relationship between Column I.D., Sample Loading Volume and Flow Rate In preparative operations, column internal diameter sizes from 6.0 to 100 mm are widely used. When the analytical

More information

Restek Ultra II HPLC Columns

Restek Ultra II HPLC Columns Restek Ultra II HPLC Columns THE Choice for All U(HPLC) Systems November 2009 1 www.chromtech.net.au, sales@chromtech.net.au, Tel: 03 9762 2034, Fax: 03 9761 1169 Topics for Today Introducing Restek Ultra

More information

02009R1223 EN

02009R1223 EN ANNEX VI LIST OF UV FILTERS ALLOWED IN COSMETIC PRODUCTS CAS EC M1 1 2 N,N,N-Trimethyl-4-(2- oxoborn-3-ylidenemethyl) anilinium methyl sulfate Camphor Benzalkonium Methosulfate 52793-97-2 258-190-8 6 %

More information

ACE C18-AR Use the Power!

ACE C18-AR Use the Power! combines the retention and separation characteristics of a C18 phase with the extra selectivity of an integral phenyl functional group. The combination provides extra resolving power for a wide variety

More information

CLINDAMYCIN PALMITATE

CLINDAMYCIN PALMITATE February 2018 Document for comment 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 CLINDAMYCIN PALMITATE POWDER FOR ORAL

More information

Unequalled durability against water elution. % tr

Unequalled durability against water elution. % tr Unequalled durability against water elution 2 Revolutionary aqueous durability for aminopropyl phase 1 3 4 1. fructose (2.5mg/mL) 3. sucrose (2.5mg/mL) 500 hr 2. glucose 400 hr Aqueous to non-aqueous Normal

More information

LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D

LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D Introduction Components of pharmaceutical products and food products often include high

More information

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column APPLICATION NOTE 21673 Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column Authors Aaron Lamb and Brian King, Thermo Fisher Scientific, Runcorn, UK

More information

Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products)

Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products) Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products) The target compound to be determined is 2, 4, 5-T. 1. Instrument Liquid Chromatograph-tandem mass spectrometer (LC-MS/MS)

More information

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit Kinetex 5 µm Core-Shell Columns Deliver Significant Improvements in Chromatographic Efficiency and Resolution versus Traditional Fully Porous 5 µm Columns Philip J. Koerner and Jeff Layne Phenomenex, Inc.,

More information

DRAFT MONOGRAPH FOR THE INTERNATIONAL PHARMACOPOEIA EFAVIRENZ, EMTRICITABINE AND TENOFOVIR TABLETS

DRAFT MONOGRAPH FOR THE INTERNATIONAL PHARMACOPOEIA EFAVIRENZ, EMTRICITABINE AND TENOFOVIR TABLETS September 2010 RESTRICTED DRAFT MONOGRAPH FOR THE INTERNATIONAL PHARMACOPOEIA EFAVIRENZ, EMTRICITABINE AND TENOFOVIR TABLETS (August 2010) DRAFT FOR COMMENT This document was provided by a quality control

More information

Analysis of Counterfeit Antidiabetic Drugs by UHPLC with the Agilent 1220 Infinity Mobile LC

Analysis of Counterfeit Antidiabetic Drugs by UHPLC with the Agilent 1220 Infinity Mobile LC Analysis of Counterfeit Antidiabetic Drugs by UPLC with the Agilent 1 Infinity Mobile LC Application Note Small Molecule Pharmaceuticals & Generics Author Sonja Schneider Agilent Technologies, Inc. Waldbronn,

More information

Analysis of Limonin in Citrus Juice Using QuEChERS and LC-MS/MS

Analysis of Limonin in Citrus Juice Using QuEChERS and LC-MS/MS Analysis of Limonin in Citrus Juice Using QuEChERS and LC-MS/MS UCT Part Numbers ECQUEU7-MP Mylar pouch containing 4g MgSO4, 1g NaCl, 1g Na3Cit 2H2O and 0.5g Na2Cit 1.5H2O CUMPSC1875CB2CT 2mL dspe tube

More information

HPLC Separation Tools for Membrane Protein Purification and Drug Membrane Permeability Prediction

HPLC Separation Tools for Membrane Protein Purification and Drug Membrane Permeability Prediction IAM CHRMATGRAPHY IAM CHRMATGRAPHY HPLC Separation Tools for Membrane Protein Purification and Drug Membrane Permeability Prediction Immobilized Artificial Membrane (IAM) technology is an innovative approach

More information

Abstract. Introduction

Abstract. Introduction A Fast Dilute-And-Shoot Method for Simultaneous 5-Hydroxyindoleacetic Acid (5-HIAA), Vanillylmandelic Acid (VMA), and Homovanillic Acid (HVA) LC-MS/MS Analysis in Human Urine By Shun-Hsin Liang and Sue

More information

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD ESTIMATION OF TOLVAPTAN IN BULK PHARMACEUTICAL FORMULATION

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD ESTIMATION OF TOLVAPTAN IN BULK PHARMACEUTICAL FORMULATION http://www.rasayanjournal.com Vol.4, No.1 (2011), 165-171 ISSN: 0974-1496 CODEN: RJCABP DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR AND ITS PHARMACEUTICAL FORMULATION V. Kalyana Chakravarthy * and

More information

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific Thermo Scientific GlycanPac AXR-1 Column Product Manual P/N: April, 2014 Part of Thermo Fisher Scientific Product Manual for GlycanPac AXR-1 Columns GlycanPac AXR-1, 1.9 µm, Analytical, 2.1 x 150 mm (P/N

More information

CHAPTER-2. Table of Contents. S.No. Name of the Sub-Title Page No. 2.1 Literature survey for simultaneous estimation of selected drugs by RP-HPLC

CHAPTER-2. Table of Contents. S.No. Name of the Sub-Title Page No. 2.1 Literature survey for simultaneous estimation of selected drugs by RP-HPLC 21 CHAPTER-2 Table of Contents Chapter 2. Literature Survey S.No. Name of the Sub-Title Page No. 2.1 Literature survey for simultaneous selected drugs by RP-HPLC 2.2 Literature survey for simultaneous

More information

Thermo Scientific Hypersil BDS Columns

Thermo Scientific Hypersil BDS Columns Technical Guide Version 2 Thermo Scientific Hypersil BDS Columns Robust and rugged, delivering excellent reproducibility and peak symmetry Part of Thermo Fisher Scientific Thermo Scientific Hypersil BDS

More information

The International Pharmacopoeia TENOFOVIR DISOPROXIL FUMARATE (JULY 2012)

The International Pharmacopoeia TENOFOVIR DISOPROXIL FUMARATE (JULY 2012) July 2012 RESTRICTED PROPOSAL FOR REVISION OF MONOGRAPH PUBLISHED IN THE FOURTH EDITION OF The International Pharmacopoeia TENOFOVIR DISOPROXIL FUMARATE (JULY 2012) PROPOSED REVISION FOR COMMENT This document

More information

Compliance. Minor editorial changes have been made to update the monograph to the current USP style.

Compliance. Minor editorial changes have been made to update the monograph to the current USP style. Nifedipine Extended-Release Tablets Type of Posting Revision Bulletin Posting Date 28 Jul 2017 Official Date 01 Aug 2017 Expert Committee Chemical Medicines Monographs 2 Reason for Revision Compliance

More information

Extended Temperature Range Impact on HPLC Column Stability and Performance

Extended Temperature Range Impact on HPLC Column Stability and Performance Extended Temperature Range Impact on HPLC Column Stability and Performance Stephanie J. Marin Dale Felix, Jody Clark Selerity Technologies, Inc. Salt Lake City, UT www.selerity.com The Selerity Series

More information

The Nitrofurantoin Capsules Revision Bulletin supersedes the currently official monograph.

The Nitrofurantoin Capsules Revision Bulletin supersedes the currently official monograph. Nitrofurantoin Capsules Type of Posting Revision Bulletin Posting Date 28 Dec 2018 Official Date 01 Jan 2019 Expert Committee Chemical Medicines Monographs 1 Reason for Revision Compliance In accordance

More information

Pelagia Research Library

Pelagia Research Library Available online at www.pelagiaresearchlibrary.com Der Pharmacia Sinica, 2014, 5(5):91-98 ISSN: 0976-8688 CODEN (USA): PSHIBD A novel RP-HPLC method development and validation of Perindopril Erbumine in

More information

contents of the monograph in effect today. Please refer to the current edition of the USP NF for official text.

contents of the monograph in effect today. Please refer to the current edition of the USP NF for official text. Metoprolol Succinate Extended-Release Tablets Type of Posting Notice of Intent to Revise Posting Date 26 Jan 2018, revised 12 Feb 2018 1 Targeted Official Date To Be Determined, Revision Bulletin Expert

More information

Vitamin Analysis by HPLC

Vitamin Analysis by HPLC Vitamin Analysis by HPLC Technical Note Vitamins are trace-amount organic compounds that regulate physiological functions of an organ- COSMOSIL 5C18 Fat-soluble Vitamins (1) Fat-soluble Vitamins Standard

More information

Journal of Chemical and Pharmaceutical Research

Journal of Chemical and Pharmaceutical Research Available on line www.jocpr.com Journal of Chemical and Pharmaceutical Research ISSN No: 0975-7384 CODEN(USA): JCPRC5 J. Chem. Pharm. Res., 2011, 3(1):138-144 Simultaneous RP HPLC determination of Latanoprost

More information

Should you have any questions, please contact Heather Joyce, Ph.D., Senior Scientific Liaison ( or

Should you have any questions, please contact Heather Joyce, Ph.D., Senior Scientific Liaison ( or Duloxetine Delayed-Release Capsules Type of Posting Revision Bulletin Posting Date 28 July 2017 Official Date 01 Aug 2017 Expert Committee Chemical Medicines Monographs 4 Reason for Revision Compliance

More information

A simple validated RP-HPLC method for quantification of sumatriptan succinate in bulk and pharmaceutical dosage form

A simple validated RP-HPLC method for quantification of sumatriptan succinate in bulk and pharmaceutical dosage form IJPAR Vol.4 Issue 1 Jan-Mar-2015 Journal Home page: ISSN: 2320-2831 Research article Open Access A simple validated RP-HPLC method for quantification of sumatriptan succinate in bulk and pharmaceutical

More information

Phases Available Description Applications Additional Notes RCM-Monosaccharide (L19 packing)*

Phases Available Description Applications Additional Notes RCM-Monosaccharide (L19 packing)* Carbohydrate and Organic Acid Analysis Excellent resolution Wide range of selectivities Excellent column-to-column reproducibility Recommended alternative to Bio-Rad, Supelco Supelcogel and Waters Sugar-Pak

More information

Insulin SEC analysis. Insulin Samples:

Insulin SEC analysis. Insulin Samples: EE1 Insulin SEC analysis Insulin Samples: Lispro, identical in structure to Insulin Human, except that it has lysine and proline at positions 8 and 9, respectively, of chain B, whereas this sequence is

More information

STANDARD OPERATING PROTOCOL (SOP)

STANDARD OPERATING PROTOCOL (SOP) 1 STANDARD PERATING PRTCL (SP) Subject: To determine the Contents of isoflavone in soybean products by HPLC Analysis Project/Core No.: Core B Total 9 Pages SP No.: CB0102 Modified Date: 05/15/01 BTANICAL

More information

Chemical Biology of Tea Catechins

Chemical Biology of Tea Catechins Workshop Argentina-Japan Bioscience and Biotechnology for the Promotion of Agriculture and Food Production August 4 th 2009 Chemical Biology of Tea Catechins Tsutomu NAKAYAMA Laboratory of Molecular Food

More information

HPLC Analysis of Sugars

HPLC Analysis of Sugars HPLC Analysis of Sugars Pre-Lab Exercise: 1) Read about HPLC, sugars and the experiment and its background. 2) Prepare a flowchart as appropriate for the lab exercise. 3) Note the various sugar concentrations

More information

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword   Pinnacle II Columns : 3μm or 5μm particles; 110Å pore size Silica at, for total control of quality and reproducibility. Excellent replacement for the original Hypersil material. Physical and chromatographic properties similar

More information

Gerry Hendrickx Regional Sales Manager Central Europe. Developments in Waters Column Chemistries : BEH Technology

Gerry Hendrickx Regional Sales Manager Central Europe. Developments in Waters Column Chemistries : BEH Technology Gerry Hendrickx Regional Sales Manager Central Europe Developments in Waters Column Chemistries : BEH Technology XTerra Columns: First Generation Hybrid Particles Initial Launch 1999 Advantages of XTerra

More information

SPE Cartridges. All Finneran Products Are Certified. Conditioning Sample application Wash Elution

SPE Cartridges. All Finneran Products Are Certified. Conditioning Sample application Wash Elution All Finneran Products Are Certified Finneran Solid Phase Extraction (SPE) cartridges provide a fast and efficient sample clean-up and concentration prior to analysis through GC, HPLC, and/or other instrument

More information

Calibration Standards

Calibration Standards Calibration Standards/ Calibration Standards TSKgel standards polystyrene TSKgel standards poly(ethylene oxide) PStQuick polystyrene calibration standards TSKgel guard column products Fittings Pre-injector

More information

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis Product # LS-R1-4.6x150 Ludger Document # LS-R1-DMB-Guide-v5.1 Ludger Ltd Culham Science Centre Oxford OX14 3EB United

More information

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis Product # LS-UR2-2.1x100 Ludger Document # LS-uR2-DMB-Guide-v2.1 Ludger Ltd Culham Science Centre Oxford OX14 3EB United Kingdom

More information

Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016.

Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016. Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016 Allura Red AC This monograph was also published in: Compendium of Food Additive

More information

Hypersil BDS and Hypersil Classical HPLC Columns

Hypersil BDS and Hypersil Classical HPLC Columns LC Columns and Accessories Hypersil BDS and Hypersil Classical HPLC Columns Exceptionally reliable and reproducible general purpose columns Exceptionally reliable robust columns that guarantee you have

More information

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns Shuguang Li, Sky Countryman, and Erica Pike Phenomenex,

More information

UCT SELECTRA C18 HPLC COLUMN INNOVATION THROUGH CHEMISTRY

UCT SELECTRA C18 HPLC COLUMN INNOVATION THROUGH CHEMISTRY UCT SELECTRA C18 HPLC COLUMN INNOVATION THROUGH CHEMISTRY SELECTRA C18 HPLC COLUMNS Benefits Good choice for easily converting current C18 methods Suitable for most traditional reverse phase analyses High

More information