The IMZ Implant System
|
|
- Christine Newman
- 5 years ago
- Views:
Transcription
1 The Implant System The Implant System was developed in Germany by Dr. xel Kirsch in the early 1970 s. is the only major implant system using a shock absorbing intermobile element designed to simulate the periodontal ligament. Two types of implants were made the Original nonhex and the Hex Head external hex (ranemark RP compatible). Original & non-hex Hex Head & external hex - Original - Hex Head Original The original implant was manufactured in two diameters mm and mm. The internal thread of the mm implant is 2.3mm and the mm implant has a 3.0mm internal thread. The external implant body is either titanium plasma sprayed or H coated with hydroxalappetite. The implant body is no longer sold, however, restorative components, such as the IME, IMC, and UM are still available from ttachments International. Hex Head - ranemark RP Compatible The Hex Head implant also manufactured in two diameters mm and mm was added in oth are restoratively compatible with the ranemark Regular Platform implant. For restorative compatible components refer to the ranemark section of this manual. Compatible components made by ttachments International are available for: Implants Original & non-hex Restoratively Compatible To none Hex Head & external hex ranemark, Regular Platform 4.1 Refer to ranemark RP Section for 3i Minimplant & Standard Osseotite compatible Hex Head Implamed RP components Innova Entegra 3.25 & REmark-ST RP Steri-Oss Hex-Loc 3.8 & 4.5 Restore RD & Sustain RD Taper-Lock ømm 2.3mm Thread Diameter ømm 3.0mm Thread Diameter ø4.1mm Platform 2.0mm Thread Diameter 2.7mm 3.4mm External Hex 2.7mm 2.3mm Thread 3.0mm Thread 2.0mm Thread Original Original Hex Head Non-Hex Non-Hex ranemark RP Implant Diameter Implant Diameter Compatible Implant Diameters & ll product names referenced herein are trademarks of their Copyright 2007 ttachments International, Inc., San Mateo, C 249
2 Terminology of Components & Page Header Sample Guide Direct To The Implant Healing Caps Implant nalog Components listed on page Compatible Implant Name Direct To The Implant Indirect Components - Original Restoration Connection Restorative Components: For ease in selecting components, the ranemark Section is divided by Restoration Connection: Direct To The Implant or Indirect To n Intermediate Component (Tissue Extensions/butments). Overdenture ttachments, ar Systems, Indirect Individual Parts and Tools are found following in the Indirect Section. NEW: 7 REFERENCE CHRTS are found at end of this section to illustrate the complex relationship of the - IME - IMC components. The Direct Restorative Components are the elements used to fabricate a restoration that will be connected directly to the implant(s). The Indirect / Intermediate Restorative Components fit to an intermediate tissue extension (abutment) which in turn is connected to the implant(s). Implant ody: The implant body is surgically placed into the bone. One surgical method traditionally involved a two-stage surgery, leaving the implant unloaded in the bone to allow for osseointegration, followed by tissue surgery to uncover the implant before the restorative components are added. nother method, called Immediate Loading, is a one-stage surgery where the abutment and restoration are attached to the implant at the time of implant placement. IME & TIE UM Intermediate Connector / Tissue Extension / IME / TIE: The TE (Tissue Extension) is the intermediate connector between the implant and the restoration, it may extend above the tissue. In some instances, a TE extension is subgingival, to provide a more esthetic restoration. The original tissue extension was the plastic IME (Inter Mobile Element) with the metal TIE. Implant Standardization: The UM tissue extension was developed to standardize the components and instruments for many different implant allowing for an economical inventory and for simplicity of restorative procedures. Its tapered/hexagon fitting surface is identical, regardless of the size or type of implant employed, while its screw-in base is implant specific. Compatibility: Implants Original & non-hex Restoratively Compatible To none Hex Head & external hex ranemark, Regular Platform 4.1 Refer to NOELranemark RP Section 3i Minimplant & Standard Osseotite for compatible Hex Head Implamed RP components Innova Entegra 3.25 & REmark-ST RP Steri-Oss Hex-Loc 3.8 & 4.5 Taper-Lock ll product names referenced herein are trademarks of their respective companies. Copyright 2006 ttachments International, Inc., San Mateo, C 248
3 Non-Hex & Direct To The Implant Healing Caps Impression Copings nalogs HELING CPS Healing caps are used to maintain access through tissue during healing phase. They are available in various heights to accommodate tissue depth and require the.050" hex driver. Small Implant Diameter Medium Implant Diameter Description Dimensions Order # Order # Healing Caps To Fit Implant Implant Healing Cap H=2.0mm Implant Healing Cap H=mm Implant Healing Cap H=6.0mm TOOLS DDS Hex Driver.050" IMPRESSION COPINGS Impression copings are used to take an impression of the implant body. The Impression Copings which fit the implant bodies are made of titanium and transfer the thread timing. For the -Hex Head implant, refer to the ranemark RP compatible section. Small Implant Diameter Medium Implant Diameter Description Order # Order # Impression Copings To Fit Implant Impression Coping for NLOGS nalogs are used for the fabrication of a master model. They are replicas of the implant body. Description Order # Order # nalogs To Fit Implant Implant ody nalog to fit, rass ll product names referenced herein are trademarks of their Copyright 2007 ttachments International, Inc., San Mateo, C 251 dditional Information:
4 Non-Hex & Direct To The Implant Titanium Posts Ti-locs TITNIUM POSTS The direct titanium abutment posts screw into the implant body and are indicated for ridge Restorations only. They may be secured with Teflon tape or thread adhesive. The titanium tapered posts can be altered like a preparation. Fabricate a soft tissue model whenever preparations are made in the laboratory. Small Implant Diameter Medium Implant Diameter Description Order # Order # Direct Titanium Posts () USE WITH: Impression Coping Implant ody nalog REQUIRES.050" HEX DRIVER: DDS.050" Hex Driver Lab.050" Driver IO-TORQ Tip Hex.050", Short (Use with io-torq Wrench) IO-TORQ Tip Hex.050", Long (Use with io-torq Wrench) TI-LOC The titanium bloc screws into the non-hexed implant body and may be secured with Teflon tape or thread adhesive. The Ti-loc requires more preparation as it is a true cylindrical bloc. However, the Ti-loc can be prepared like a posterior prep, thereby increasing the esthetics and comfort. It can also be prepared to correct for divergency. Insertion requires.050" hex driver..050" hex.050" hex Description Dimensions Order # Order # Ti-loc small () ø=4.7mm Ti-loc small () ø=5.0mm USE WITH: Impression Coping Implant ody nalog REQUIRES.050" HEX DRIVER: DDS.050" Hex Driver Lab.050" Driver IO-TORQ Tip Hex.050", Short (Use with io-torq Wrench) IO-TORQ Tip Hex.050", Long (Use with io-torq Wrench) ll product names referenced herein are trademarks of their Copyright 2010 ttachments International, Inc., urlingame, C 256 dditional Information:
5 Non-Hex & Indirect IME butments Titanium Plastic IME with TIE IME COMPONENTS Titanium Plastic Modified IME IME UTMENT IME butments (tissue extensions) are intermediate components made to fit between the implant and the restoration. The IME, in plastic or Titanium, requires the Titanium TIE. The Modified IME, in plastic or Titanium, fits directly to the implant. Restorations can be made on the abutment using abutment cylinders. The UM Healing Cap protects the IME until restoration is delivered. The Impression Coping takes an impression of the abutment and transfers abutment position and thread timing. The nalog is a replica of the abutment and is used for fabrication of a master model. The CSP (Cylinder, Screw & Plug) is used for crown & bridge and bar restorations. SEE REFERENCE CHRTS #1 & #2 (at end of section) Reference UM Indirect page for Healing Caps to fit IME. Tapered C 2 Pc C 2 Pc C D E E Impression Coping Imp Coping 2pc Imp Coping 2pc nalog CSP mm CSP mm Description Dimensions Intended Use Order # Order # C D E IME (Intramobile Element) Tissue Extension Height Tissue Extension / butment IME, Plastic (requires TIE) 2.0mm U U IME, Plastic (requires TIE) mm N/ U IME, Titanium (requires TIE) 2.0mm TU TU IME, Titanium (requires TIE) mm N/ TU TIE (Transmucosal Implant Extension) Collar Extension TIE, Titanium (not for Mod. IME) 1.0mm TIE, Titanium (not for Mod. IME) 2.0mm TIE, Titanium (not for Mod. IME) mm Modified IME (Modified Intramobile Element) Tissue Extension / butment IME, Plastic (direct to implant) MU MU IME, Titanium (direct to implant) MU MU Components To Fit IME and Modified IME/ Tissue Extension Impression Coping Impression Taking / Transfer Timing Tapered Impression coping, transfer thread timing (closed tray) Impression coping, 2 piece, transfer thread timing (open tray) nalog Model Fabrication IME / nalog, rass (Replicates both IME & Modified IME) CSP (Cylinder, Screw & Plug) Crown & ridge / ar Restorations IME CSP, Non-Engaging Cylinder,.050" Hex Screw and Plug PRTS Plastic Cylinder Only, Long for or (also fits the IMC & ) Plastic Cylinder Only, Short for or (also fits the IMC & ) Ti Hex.050" Screw Only (To fit IME and Complete butment) TOOLS Reamer, UM butment Carbide.0880" (requires Pin Vise ) Pin Vise for Carbide Reamers " UM, Lapping Tool and Guide Pin Reamer Friction Grip Driver (for plastic IME) Pin Vise IO-TORQ Tip, UM, Short (for Titanium IME only) IO-TORQ Wrench 30 N/cm ll product names referenced herein are trademarks of their Copyright 2007 ttachments International, Inc., San Mateo, C 253
6 Non-Hex & Indirect IMC butment Titanium IMC Connector IMC UTMENTS (Intramobile Connector) The original IMC (Intramobile Connector) consists of a titanium insert and a plastic element (donut). The Ti IMC is a onepiece titanium abutment that replaces the original titanium insert and plastic element. The IMC two-piece impression coping connects to the original plastic IMC or the Ti IMC. The Plastic IMC Element C IMC analog is used to fabricate a working model. Castablemachined plastic cylinders are used in the fabrication of the screw-retained framework. SEE REFERENCE CHRTS #1 - #4 (end of section) IMC Titanium Insert Ti IMC Connector IMC COMPONENTS Note: Thread is only in lower portion of both the IMC Connector and the IMC nalog, requiring the longer IMC screw. Original IMC Ti Insert & IMC Plastic Element Fits: IME & IMC & Fits: IME & IMC & D Impression Coping E nalog Thread in lower portion F Description Dimensions Intended Use Order # Order # Long F Short C D E F IMC Titanium Connector IMC Ht Overall Ht Tissue Extension / butment Ti IMC, Titanium 1.0mm 1.8mm CU Ti IMC, Titanium 2.0mm 2.8mm CU CU Ti IMC, Titanium Conversion 3.5mm CU Ti IMC, Titanium 3.0mm 3.8mm CU CU Ti IMC, Titanium mm 4.8mm CU CU IMC Titanium Insert Insert & Element IMC Ti Insert (requires IMC Element) 1.0mm 1.8mm C IMC Ti Insert (requires IMC Element) 2.0mm 2.8mm C C IMC Ti Insert (requires IMC Element) Conversion 3.5mm C IMC Ti Insert (requires IMC Element) 3.0mm 3.8mm C C IMC Ti Insert (requires IMC Element) mm 4.8mm C IMC Plastic Element Insert with butment IMC, Intramobile Element, Plastic ushing ("donut") C C Components To Fit IMC Connector and IMC Insert Impression Coping, 2 Piece Impression Taking / Transfer Timing IMC 2 Piece Impression coping, transfers thread timing nalog Model Fabrication IMC nalog, rass PRTS Plastic Cylinder Only, Non-Engaging, Long for or (also fits the IME & ) Plastic Cylinder Only, Non-Engaging, Short for or (also fits the IME & ) NOTE: Screws indicated depend on initial restoration. See Flow Charts #5 & #6 for complete list of available screws. Contact Technical Support for further information, TOOLS Reamer, UM butment Carbide.0880" (requires Pin Vise ) Pin Vise for Carbide Reamers " UM, Lapping Tool and Guide Pin IO-TORQ Tip / IMC, Short IO-TORQ Wrench 30 N/cm ll product names referenced herein are trademarks of their Copyright 2007 ttachments International, Inc., San Mateo, C 254
7 Non-Hex & Compatible Indirect UM butment UM COMPONENTS UM UTMENT The UM butment (tissue extension) is an intermediate component made to fit between the implant and the restoration. The UM has a standardized fitting surface, which allows the UM restorative components to be interchangeable regardless of the implant type. The UM Healing Cap protects the UM until the restoration is delivered. The ridge Tapered UM Impression Coping transfers the UM position while the Hex UM Impression Coping transfers the hex orientation of the UM butment. The UM nalog replicates the UM for the model. The UM Hex or Non-Hex Plastic Cylinders are used to make frameworks for bridges or bars. The UM CL System is used for a passive fit technique. For restorations the fit directly to the implant refer to the UCL System for the specific implant type. C C D E E Healing Cap Impression Coping Impression Coping nalog CSP CSP CL Cylinder Tapered 1 piece Hex 2 piece rass Hex Cyl, Hex screw Non-Hex Cyl, Hex Screw Description Dimensions Intended Use Order # Order # C D E F UM butment Tissue Extension Height Tissue Extension / butment UM, butment H=0.5mm N/ UM, butment H=1.0mm N/ UM, butment H=2.0mm UM, butment H=3.0mm UM, butment H=mm UM, butment H=5.0mm UM, butment H=6.0mm UM, butment H=7.0mm Components To Fit UM butment / Tissue Extension Healing Cap Tissue Healing / Management One Thread Size Fits ll UMs UM Healing Cap H=2.0mm ø=4.5mm UM Healing Cap H=mm ø=4.5mm UM Healing Cap H=6.0mm ø=4.5mm Impression Coping Impression Taking / Transfer Timing UM Impression Coping Tapered, one piece UM Impression Coping Hex with.050" Hex Guide Pin, two piece nalog Model Fabrication UM nalog, rass CSP (Cylinder, Screw & Plug) Crown & ridge / ar Restorations UM Hex Cylinder (blue), Ti.050" Hex Screw & Occlusal Plug UM Hex Cylinder (blue), Ti Slot Screw & Occlusal Plug UM Non-Hex Cylinder (yellow), Ti.050" Hex Screw & Occlusal Plug UM Non-Hex Cylinder (yellow), Ti Slot Screw & Occlusal Plug CL Cylinder (Passive Fit) ars / Fixed Detachable UM CL Cylinder, Ti.050" Hex Screw, Waxing Sleeve & Spacer NOTE: Slot Screws (# ) may be ordered separately. PRTS UM.050" Hex Titanium Screw, only UM, Short ar Cylinder only, Red FOR INDIVIDUL UM PRTS & TOOLS Refer to the UM Section of this Manual. ll product names referenced herein are trademarks of their respective companies. Copyright 2006 ttachments International, Inc., San Mateo, C 253 dditional Information:
8 Non-Hex & Dalla ona & ORS Overdenture ttachments OVERDENTURE STUD TYPE TTCHMENTS Three types of overdenture attachments are most commonly used to directly screw into the implant the Dalla ona, the ORS, (O-Ring system) and the Locator. Connectors are made of titanium. Dalla ona male, ORS male and Locator female are sold separately by tissue height. The D Female Kit includes 1 adjustable female, 1 spacer and 1 brass analog. The ORS Female Kit includes 1 gold plated retainer ring, 3 white final & 3 red processing O-Rings and 1 brass analog. Locators are listed on a separate page. D D ORS ORS or C C llegro Implant Female Kit Optional for D Small Implant Diameter Medium Implant Diameter Description Dimensions Order # Order # Dalla ona System () Dalla ona, male only H=1mm Dalla ona, male only H=2mm Dalla ona, male only H=3mm Dalla ona, male only H=4mm H Dalla ona, male only H=5mm Dalla ona, male only H=6mm Dalla ona, male only H=7mm Dalla ona, Implant Ti Female: Fe, Spacer & nalog Fø=3.4mm llegro, Implant Female Kit (option for Dalla ona female) () includes Metal Housing, 4 Females, Implant Spacer & rass nalog ORS, O-Ring System (C) ORS, male only H=1mm ORS, male only H=2mm ORS, male only H=3mm ORS, male only H=4mm H ORS, male only H=5mm ORS, male only H=6mm ORS, male only H=7mm ORS, Implant Female Kit, includes Retainer Ring, nalog & O-Rings (6) PRTS & TOOLS For Dalla ona, llegro & ORS Parts and Tools, refer to next page. Locators are listed on a separate page. For Hex Head & External Hex compatible components, refer to the ranemark RP / Direct section of this manual. ll product names referenced herein are trademarks of their Copyright 2010 ttachments International, Inc., urlingame, C 263 dditional Information:
9 Non-Hex & Compatible Dalla ona, ORS & llegro Parts & Tools for Overdenture Stud Type ttachments OVERDENTURE STUD TYPE TTCHMENT PRTS & TOOLS Two types of overdenture attachments are most commonly 1 spacer and 1 brass analog. The llegro Female Kit is used to directly screw into the implant the Dalla ona and offered as an option for the Dalla ona System. The ORS the ORS, (O-Ring system). Connectors are made of titanium. Female Kit includes 1 gold plated retainer ring, 3 white final & Dalla ona males and ORS males are sold separately by tissue height. The D Female Kit includes 1 adjustable 3 red processing O-Rings and 1 brass analog. female, PRTS Description Dimensions Order # DLL ON FOR IMPLNTS Dalla ona, Implant Female Kit: includes Female, Spacer & rass nalog Dalla ona, Resilient Female, Gold FH=3.1mm Dalla ona, Resilient Female, Titanium FH=3.4mm Dalla ona, Resilient Female, Plastic (4) FH=3.5mm Dalla ona Hex nalog, rass (2) Dalla ona Hex Spacer, rass (2) PVC Ring (6), replacement ring for Dalla ona female LLEGRO FOR IMPLNTS llegro, Implant Female Kit (option for Dalla ona female) includes Metal Housing, 4 Females, Implant Spacer & rass nalog ORS FOR IMPLNTS ORS, Retainer Rings (6) H=2.0mm ø=5.1mm ORS, Combo O-Rings: 6 blue, 6 red (processing), 6 wt, 6 blk Outside ø=4.5mm Inside ø=1.4mm ORS, Implant Female Kit: includes Retainer Ring, rass nalog and 3 red processing & 3 white final O-Rings O-Ring Hex nalog, rass (2) TOOLS IO-TORQ Wrenches, Socket & Driver IO-TORQ Wrench 10 N/cm IO-TORQ Wrench 20 N/cm IO-TORQ Wrench 30 N/cm IO-TORQ Wrench 35 N/cm IO-TORQ Socket IO-TORQ Extension IO-TORQ ORS / Dalla ona Tip/Driver LT/R DRIVER LT/R R Hand Driver LT/R R Handle / Socket LT/ R ORS / Dalla ona Tip Dalla ona ctivating Tool, lue Dalla ona Deactivating Tool, Yellow LLEGRO (for replacement parts see llegro OD section page 99) llegro OD/DE Micro/Regular Insertion Tool Dalla ona ctivating Tool Dalla ona Deactivating Tool ll product names referenced herein are trademarks of their Copyright 2010 ttachments International, Inc., urlingame, C 264 dditional Information:
10 Non-Hex & Compatible Overdenture ar Restorations IDEL R RESTORTIONS There are numerous options for implant bar restorations available today. To simplify your search, we have selected the most proven and popular systems on this page. For a complete listing of all bar system components, refer to the ar and Clip Quick Reference Charts. Most implant bar restorations involve from 2 to 5 implants. The ideal implant bar system incorporates a bar and retentive clips in the anterior section and locking pin attachments distally for support and stability. The Hader-EDS ar Master kit is the preferred choice. The CM Gold Clips may be used as an alternative. The locking SwissLoc NG ttachment is the preferred distal attachment to prevent lift-off and still provide resiliency. The Lew ttachment is a viable alternative. For Laser Welding Technique, use only titanium bars and posts. Recommended parts needed for a successful bar restoration: PPM ar 0 degree SwissLoc ttachments Hader-EDS Clips Hader-EDS ar Description Order # HDER-EDS R MSTER KIT Master Kit includes 6 yellow plastic clips, 6 metal housings, 2 seating tools and 2 short plastic bars (50mm) TOOLS: Hader-EDS ar nalog 50mm, aluminum (1) Hader-EDS Fabricating Rider / Clip (6) Green Hader-EDS Impression Clip (6) lue CM HDER-EDS R KIT CM Kit includes 6 CM gold riders (clips) with spacers and 2 short plastic Hader-EDS bars (50mm) TOOLS: CM djusting Tool (can be used with all metal riders / sleeves) CM ar nalog 50mm (aka Hader-EDS ar nalog), aluminum PRTS Hader-EDS Combo Clips (18) 6 white, 6 yellow, 6 red and 1 seating instrument Hader-EDS ar, short plastic (6) Green Hader-EDS Metal Housings (6) Gold SWISSLOC NG TTCHMENT SwissLoc NG mm *L=4.5mm Housingø=3.4mm Plungerø=1.5mm X SwissLoc NG 6.0 mm *L=6.8mm Housingø=3.4mm Plungerø=1.5mm X SwissLoc NG 7.5 mm *L=8.0mm Housingø=3.4mm Plungerø=1.5mm X *Note: SwissLoc NG 7.5 can be reduced to 4mm. Length is measured in closed position from head of plunger to end of housing. TOOLS: SwissLoc NG Screwdriver SwissLoc NG Processing Jigs (2) SwissLoc NG 1.5mm Drill (1) PPM PLSTIC R PTTERNS (50mm) PPM ar 0 degree (3 short 3.7mm, 3 tall 8.0mm), blue PPM ar 2 degree (3 short 3.7mm, 3 tall 8.0mm), red PPM ar 4 degree (3 short 3.7mm, 3 tall 8.0mm), yellow TOOLS: PPM ar Mandrel 0 degree (for plastic or titanium bar) PPM ar Mandrel 2 degree (for plastic or titanium bar) PPM ar Mandrel 4 degree Hader-EDS Housing REPLCEMENT R CLIP WITH SCREWS & CKPLTE White ar Clip & Screw (2) ssembly and ackplate Fits original 2mm diameter bar. Used for overdenture bar restorations. Includes: 1 white clip, 2 screws and 1 backplate. PRTS White ar Clip only Screw only ackplate only ll product names referenced herein are trademarks of their respective companies. Copyright 2006 ttachments International, Inc., San Mateo, C 256 dditional Information:
11 Non-Hex & Insertion Drivers Tools INSERTION DRIVERS The IO-TORQ (-T) and LT / R Systems were designed to facilitate the insertion of implant components. The IO- TORQ insertion tips may be utilized with the IO-TORQ hand held socket or the IO-TORQ wrenches. The LT / R (latch type) tips are used with right angle handpiece type drivers. IO-TORQ LT / R C D F G H J Socket Extension Slot Hex IMC IMC UM sht UM long C D E H Handle Slot Hex Complete UM Description Order # Order # io-torq LT/R Driver Hand Held Socket / Handle () IO-TORQ Extension () N/ Slot Tip Short Slot Tip Long (C) " Hex Tip Short " Hex Tip Long (D) " Hex Tip Short " Hex Tip Long Dalla ona / ORS Hex Tip Locator Tip, short Locator Tip, long Complete butment LT / R Tip (E) N/ IO-TORQ Tip / IMC, Short (F) N/ IO-TORQ Tip / IMC, Short (G) N/ UM Tip Short (H) UM Tip Long (J) N/.9mm CS Hex Tip Short N/ STNDRD DRIVERS, -T WRENCHES & LT / R DRIVER Note: For Slot Screws do not exceed 10 N/cm of torque. C D Description Order # Standard Drivers and FG Drivers DDS.050" Hex Driver () DDS Slot Screwdriver () Lab.050" Driver (C) Friction Grip Driver (D) IO-TORQ Wrenches & LT / R Driver IO-TORQ Wrench 10 N/cm IO-TORQ Wrench 20 N/cm IO-TORQ Wrench 30 N/cm IO-TORQ Wrench 35 N/cm LT / R Driver ll product names referenced herein are trademarks of their Copyright 2007 ttachments International, Inc., San Mateo, C 259
12 Non-Hex & Compatible Reamers Lapping Tools REMERS The carbide reamers are used to refine the internal access hole of a castable cylinder. They also refine the seat for the head of the screw. Each carbide reamer and Pin Vise are sold separately. The Pin Vise will fit all carbide reamers. The Reamer fits all UM and IME European new style cylinders. Pin Vise Reamer Description Order # Reamer, UM butment Carbide.0880" (also fits & Paragon UCL Cylinders) (requires Pin Vise ) Pin Vise for Carbide Reamers " LPPING TOOLS The Lapping tools are used with diamond polishing paste to refine the fitting surface of the cast cylinder. We recommend that you use it not more than 5-6 times. For superior restorations, you may want to use the 1 micron white diamond lapping paste. The lapping tool fits the cylinders for the Complete butment, IME and UM. Description Order # UM, Lapping Tool and Guide Pin ll product names referenced herein are trademarks of their respective companies. Copyright 2006 ttachments International, Inc., San Mateo, C 258 dditional Information:
13 Non-Hex & Screws for Original Parts SCREWS FOR ORIGINL COMPONENTS & & Hex Hex Hex C D E F G H IMC Conversion IMC Coping Screw IME Coping Screw IMC Fastening IMC Fastening IME Fastening Screw Securing Screw Hex Head Screw for Plastic Cylinder for Gold Cylinder for Gold Cylinders ar Clip to & ack Plate Implant Screw LL SCREWS HVE.050" HEX except ack Plate Screw (slot) Description Order # Order # mm mm IMC Conversion Screw,.050" Hex () C C Used when converting from IME to IMC butment. Threads must be shortened to appropriate length. mm ONLY fits IMC butment mm Fits both IMC & IME butments. 2.2mm ø head. IMC Coping Screw,.050" Hex () C C Used for overdenture bars. Screw has 2.8mm diameter head. IME Coping Screw,.050" Hex (C) Used for overdenture bars. Screw has 2.8mm diameter head. IMC Fastening Screw for Plastic Cylinder,.050" Hex (D) C C Screw has 2.4mm diameter head. IMC Fastening Screw for Gold Cylinder,.050" Hex (E) C C Screw has 2.2mm diameter head. IME Fastening Screw for Gold Cylinder,.050" Hex (F) Hex is in base of screw head allowing screw head to be shortened if necessary. 2.2mm ø head. Screw to Secure ar Clip to ack Plate &, slot (G) For securing plastic clip to the ack Plate ONLY. Screw for & Hex Head Implant,.050" Hex (H) For Hex Head & Implant ONLY. Note: For detailed dimensions of screws see Reference Charts immediately following this page. ll screws have.050" hex. IME butment Inner thread is located in TOP portion of abutment IMC butment Inner thread is located in OTTOM portion of abutment Note the difference in placement of screw threads in the abutments. IME threads are located at the top, IMC threads are located at the bottom. ll product names referenced herein are trademarks of their Copyright 2007 ttachments International, Inc., San Mateo, C 261 dditional Information:
Steri-Oss Compatible Components
Original Non-Hex & Direct To The Implant Impression opings nalogs IMPRESSION OPING To Fit Implant The impression coping for the Steri-Oss Original Non-Hex implant is used to take an impression of the implant
More informationFor Threadloc 3.75 (implant discontinued - components available in Branemark section) For Spline SD, RD & WD (only Locator components available)
Integral Integral Internal Non-Hex (flat-top) Implants The Integral Implant System was developed in the early 1980 s by Calcitek of Carlsbad, C. Calcitek, acquired by Zimmer Dental, was a pioneer and market
More informationExternal Hex 4.1 & 5.0 platform
Biomet 3i System External 4.1 & 5.0 platform Internal Certain 3.4, 4.1 & 5.0 platform Osseotite Standard Osseotite TG Osseotite CERTAIN 3i was founded in 1987 by Dr. Lazarra and Keith Beatty in West Palm
More informationPart 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants
Select Part 2 Internal Tri-Channel Connection Replace Select NobelSpeedy Replace NobelReplace and compatible implants listed below Select Part 2 contains only the Tri-Channel Internal Connection compatible
More informationRENEW BIOCARE GENERIC RESTORATIVE COMPONENTS
RENEW IOCRE GENERIC RESTORTIVE COMPONENTS COMPTILE WITH: RENEW UM Universal Modification butment Nobel iocare ranemark, NP, RP, WP Hex-Loc, Replace Steri-Oss ITI onefit Straumann Osseotite 3i Implant Innovations,
More informationPRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable.
PRODUCT CATALOG Since 1985» Simple. Predictable. Profitable. 2014 IMPLANTS HEALING PLUG INSERTERS COLLAGEN PRODUCTS 3.0mm Well Integra-CP Part No. DIAMETER LENGTH Price 345-306 4.5mm mm $280.00 345-308
More informationProduct Catalog. Since 1985» Simple. Predictable. Profitable.
Product Catalog Since 1985» Simple. Predictable. Profitable. 2011 IMPLANTS 3.0mm Well Integra-CP Part No. DIAMETER LENGTH 345-306 4.5mm 6.0mm 345-308 4.5mm 8.0mm 345-311 4.5mm 11.0mm 350-305 5.0mm 5.0mm
More information4766 Research Dr. San Antonio, TX insightdentalsystems.com
OVERVIEW OF THE INSIGHT DENTAL IMPLANT DELIVERY SYSTEM The IDS system comes in a unit dose implant system where its advantage provides sterile instrumentation in one single-use kit. It is organized to
More informationNARROW DIAMETER implant
ND NARROW DIAMETER implant TABLE OF CONTENTS ND - NARROW DIAMETER implant Implant characteristics page 04 Dental implant page 05 Open Tray Impression Transfer page 06 Titanium Abutments page 07 O-Ball
More informationUniversal Plunger Loc Attachment
Universal Plunger Loc Attachment www.preat.com 800-232-7732 Universal Plunger Loc Complete Universal 7.5mm length TI plunger attachment. Compatible with Lew Passive and Swiss Loc NG. 1.5mm plunger, 7.5mm
More informationLegacy Prosthetic Catalog
Legacy Prosthetic Catalog Straight Snap-On Straight Contoured Angled Contoured Ball Attachment Gold/Plastic Castable Locator Attachment Plastic Temporary Screw Receiving Plastic Non-Engaging Castable 15
More informationSwissPlant Prosthetic Catalog. SwissPlant
SwissPlant Prosthetic Catalog Contoured Snap-On Angled Contoured Ball Attachment Gold/Plastic Castable Locator Attachment Plastic Temporary Screw Receiving Plastic Non-Engaging Castable Narrow Titanium
More informationEXTERNAL HEX INTERNAL HEX NTERNAL. ENDOPORE Product Catalog
Osteotome PROCEDURES perfect NTERNAL PERFECT SURFACE ENDOPORE Product Catalog INTERNAL HEX PerfeCT SURFACE EXTERNAL HEX Implant Placement Procedure ENDOPORE Table of Contents ENDOPORE Contents Endopore
More informationOT EQUATOR CASTABLE Single Attachment for Overdentures
OT EQUATOR CASTABLE Single Attachment for Overdentures pick-up impression OT EQUATOR PROFILE CASTABLE MALE ATTACHMENT individual tray RETENTIVE CAPS OT EQUATOR HOUSING VIOLET CAP RIGID RETENTION (2.7Kg)
More informationSimpleLine II Surgical / Prosthesis Manual
SimpleLine II Surgical / Prosthesis Manual SimpleLine II SURGICAL MANUAL Surgical Drill Sequence 04 Fixture Installation 05 Fixture Connection 06 Surgical Kit Maintenance 08 Warnings 09 04 SimpleLine ll
More informationHeight* FC width Prep depth RC width 4.0mm+ 4.3mm N/A 6.3mm
STERN ERA IMPLANT ABUTMENT Summary Resilient precision overdenture attachment. Universal hinge with vertical movement. Titanium abutment, nylon male. Manufactured for most popular screw and cylinder implants.
More informationCATALOG. Since 1985» Simple. Predictable. Profitable.
CATALOG Since 1985» Simple. Predictable. Profitable. 2018 19 IMPLANTS SYNTHOGRAFT TEMPORARY ABUTMENTS (Ti) 3.0mm Well Integra-CP PART NO. DIAMETER LENGTH PRICE 345-305 4.5mm 5.0mm $290.00 345-306 4.5mm
More informationUS Implant System 2013 PROSTHETIC PROCEDURE
US Implant System 2013 PROSTHETIC PROCEDURE Contents TS Implant System Cement retained restoration 06 Cement retained bridges with the Cement abutment system 18 Cement retained crown with the Angled abutment
More information- RESTORATIVE PRODUCT CATALOG
- RESTORATIVE PRODUCT CATALOG MADE IN USA Others make Implants to sell... Tatum Surgical makes Implants to treat your Patients. Your Source for Implants To Meet Every Clinical Need Tatum... 4 Angled Post
More informationSmarter Thinking. Simpler Design. TiLobe Prosthetic Manual for PrimaConnex & Genesis implants
Smarter Thinking. Simpler Design. TiLobe Prosthetic Manual for PrimaConnex & Genesis implants Dear Customer, Thank you for allowing Keystone Dental Inc. the opportunity to provide solutions which we hope
More informationSwishPlant. SwishPlant System Catalog. 4.8mmD mmD. 4.8mmD mmD. 3.7mmD mmD. 6.5mmD
SwishPlant System Catalog ------------ 4.1mmD ------------ 3.7mmD ------------ 3.3mmD SwishPlant 6.5mmD ------------ 6.5mmD ------------ 5.7mmD Table of Contents SwishPlant Fixture Mount Packaging Page
More informationcement-retained single crowns using cementable abutments
cement-retained single crowns using cementable abutments cement-retained restorations cement-retained single crowns using cementable abutments Cement-retained implant restorations are similar to conventional
More informationLegacy TM. System Catalog. Legacy TM 1 Legacy TM 2 Legacy TM 3 Legacy TM 4
Legacy TM System Catalog Legacy TM 1 Legacy TM 2 Legacy TM 3 Legacy TM 4 Table of Contents Page # Design, Surface & Dimensions 1-5 6-13 Legacy TM 1, Legacy TM 2, Legacy TM 3 & Legacy TM 4 s Labeling &
More informationBlue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants
BIO Multi-Units are available for all our Bone Level Implants Multi-Units abutments are ideal for following restorative plans Blue Sky Bio offers a variety of components that can be used with BIO Multi-units.
More informationTRINON. Index. Index. Overview Page 4. Catalogue
QK-Implant Information Components are updated periodically, check with your local Trinon partner on current models Please follow Instructions for Use for individual components Images are not to scale see
More informationProduct Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER
Product Catalogue 1 Product Chart Follow the lines to see which products that fits both diameters and which that are special. In true OSPOL philosophy, most of the instruments and abutments fits both diameters.
More informationStep-by-Step Cemented Bridge Using Using CPK Abutments. Internal Hex. Implant System
4. 6. Step-by-Step Cemented Bridge Using Using CPK Abutments Internal Hex. Implant System MIS Corporation. All rights reserved. Published by MIS, which reserves the right to ameliorate the products described
More informationTreatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l
Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l Two-Piece ReActive Tri-Lobe Implants with Multi-Unit Abutments One-Piece ScrewIndirect Implants
More informationIMPRESSION PROCEDURES TRAINING MANUAL
IMPRESSION PROCEDURES TRAINING MANUAL 01 01 A.B. DENTAL A.B. Dental is proud to present this impression taking procedure protocol. This manual explains, step by step, the procedure while using A.B. Dental
More informationSuperLine & Implantium Surgical / Prosthesis Manual
SuperLine & Implantium Surgical / Prosthesis Manual SuperLine & Implantium SURGICAL MANUAL Surgical Drill Sequence I 04 Surgical Drill Sequence II 06 Drilling Depth Guide 08 Fixture Connection 10 Installation
More informationInterActive System Catalog
InterActive System Catalog Table of Contents Page # Implant Design & Surface 1 2-3 2 Implant Dimensions Fixture Mount & IQity Impression Technique 3 4-5 InterActive Implants Selection Chart 10-11 6-7 8
More informationN E W S M I L E S E V E R Y D AY
C ATA LO G 2 0 6 N E W S M I L E S E V E R Y D AY Neodent provides you with a complete range of products and services that are designed and produced by a team of professionals who truly love what they
More informationsynocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions
synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions INTRODUCTION synocta Meso abutment for cement-retained restorations 1 The synocta Meso abutments, available
More informationRePlant System Prosthetic Catalog
RePlant System Prosthetic Catalog Healing Collars, Transfers, Analogs & Alignment Tools Healing Collars Components include Dual-Grip feature for use with 1.25mmD Hex Tool or Nobel Unigrip ScrewDriver Width
More informationSuperLine & Implantium Surgical / Prosthesis Manual
SuperLine & Implantium Surgical / Prosthesis Manual SuperLine & Implantium SURGICAL MANUAL Surgical Drill Sequence 04 Drilling Depth Guide 06 Fixture Connection 08 Installation Procedure & Warnings 09
More informationQZ-Implant TRINON. Bone level implant with hexagonal internal cone connection
QZ-Implant Information Components are updated periodically, check with your local Trinon partner on current models Please follow Instructions for Use for individual components Images are not to scale see
More informationSS Implant System 2013 PROSTHETIC PROCEDURE
SS Implant System 2013 PROSTHETIC PROCEDURE Contents TS Implant System Cement retained restoration 06 Cement-retained bridges with the Solid abutment system (non-modified abutment) 16 Cement-retained bridges
More informationsimply simply digital simply crown & bridge simply removable simply fixed simply à la carte
TM crown & bridge fixed removable digital à la carte imagine... being able to order the way you treatment plan so you can focus on the dentistry, rather than the components knowing your treatment costs
More informationIMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit
a perfect fit IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS Open and closed impression-taking Impression-taking for option platform switching Bite registration Temporary
More informationINSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)
INSTRUCTIONS FOR THE DENTIST synocta impression procedure, Screw-retained and Snap-on Screw-retained (Open tray) Snap-on (Closed tray) click 1. Attach synocta Impression caps to implants. Hand-tighten
More informationAstra Tech Implant System. Product catalog. OsseoSpeed TX
Astra Tech Implant System Product catalog OsseoSpeed TX Astra Tech Implant System CONTENTS Astra Tech Implant System 4 Product overview 3.0 5 Product overview 3.5/4.0 6 Product overview 4.5/5.0 8 Surgical
More informationMulti-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants
Multi-Unit Abutment System SIC Safe on Four Optimum use of available bone by angled placement of implants Multi-Unit Abutment System SIC Safe on Four Safe on Four The SIC Safe on Four system is a further
More informationproduct catalog
product catalog 2014-2015 02 Table of Contents About ADN 03 ntroduction About ADN... 3 Dental mplant Systems... 5 Surface Treatments... 6 nternal Conical Connection mplant Systems Touareg CloseFit mplant
More informationImplant Phase Flow Chart
Implant Phase Flow Chart 1. Surgical Phase Immediate Load 1. Place implant 1-2 mm below bone. 2. Attach crown posts at time of surgery using S17000 series abutments and (AS7001) Alan Key, and (AS7033)
More informationHow something small, can make such a big difference!! Your best choice in overdenture
How something small, can make such a big difference!! Your best choice in overdenture Why? Kerator has the worldʼs most powerful competitiveness in overdenture attachment system. KERATOR was chosen over
More informationHEXAGON Implant System
HEXAGON Implant System PRODUCT N 1 CATALOG 2018 2 Table of contents Implants... 4 Prosthetics Lab Components, Abutments... 5 Zest LOCATOR, R-Tx and F-Tx...6 Multi-Unit Abutments...7 Instruments...8 Zest
More informationprosthetic technique manual
prosthetic technique manual table of contents table of contents introduction modules why choose BioHorizons prosthetics? surgical and prosthetic options & impression technique overview impression technique
More informationInterActive System CONICAL. Prosthetic Catalog. simplycrown & bridge SMART PACK. InterActive All-in-1 Packaging simplyinteractive Mount-Free
InterActive System Prosthetic Catalog simplycrown & bridge SMART PACK InterActive All-in-1 Packaging simplyinteractive Mount-Free CONICAL Cover Screws, Healing Collars & Transfers Replacement Surgical
More informationMulti-unit abutment bar overdenture
Multi-unit abutment bar overdenture Use this technique for the fabrication of a multiple-unit, implant-supported, screw-retained bar with an overdenture in a totally edentulous patient. component options
More informationAbutment level impression Ⅰ. Combi abutment/dual abutment Multi units
Pr osthetic par t Abutment level impression Ⅰ Combi abutment/dual abutment Multi units Prosthetic part Remove Cover screw Prosthetic part Remove Healing abutment Prosthetic part Select suitable Combi abutment,
More informationcontents the smarter case approach reasons to choose simplyintegrated 5 system overview 6 ordering 7 mount-free implants 8-9
simply fixed angled contents the smarter case approach 3-4 3 reasons to choose simplyintegrated 5 system overview 6 ordering 7 mount-free implants 8-9 SMART PACK prosthetics 10 simplyinteractive details
More information. Simplification. High Performance. Safety and Longevity. The fundamental goal is to restore the quality of life of patients.
Catalog 4 P-I product line was developed by te Osseointegration pioneer, Professor Per-Ingvar Brånemark, jointly wit experienced scientists in world recognized entities to meet modern implant dentistry
More informationß For cement-retained crowns and bridges. Note: synocta cementable abutments. ß Can be especially helpful with large multi-unit cases Note:
Choosing the correct Straumann abutment for crowns, bridges, and bars Straumann abutments are torqued to 35 Ncm by using the ratchet with torque control device and the appropriate abutment driver. Abutments
More informationTS Implant System 2013 PROSTHETIC PROCEDURE
TS Implant System 2013 PROSTHETIC PROCEDURE Contents TS Implant System Cement retained restoration Screw retained restoration 08 When abutment reduction is unnecessary 66 Screw retained restoration 21
More informationNR Line Product Catalog
NR Line Product Catalog NR Line Contents Introduction S.L.A. Surface 04 NR Line Characteristics 06 NR Line Color Coding by Diameter 08 NR Line Fixture 09 Surgical Components Cover Screw 10 Healing Abutment
More information» For multi-unit restorations -
» For multi-unit restorations - conventional or digital «Multi-Unit Abutments 2 The Multi-unit product range is being contiunally expanded to include other abutment series. Available for a large number
More informationESTHETIC LINE implant
EL ESTHETIC LINE implant EL ESTHETIC LINE implant TABLE OF CONTENTS EL - ESTHETIC LINE implant Implant characteristics page 04 Dental implants page 05 Closed tray impression transfer page 06 Open tray
More informationXive. Product Catalog
Xive Product Catalog Versatility and ease For more than a decade, the Xive implant system has provided full restorative options. From the narrowest gap to the fully atrophied edentulous jaw, in hard or
More informationProsthetics Systems Conical Hex Connection Platform
Prosthetics Systems onical Hex onnection Platform lpha-io Tec's diverse prosthetic system provides comprehensive solutions for the onical onnection platform. Restoration options include a wide range of
More informationINTERNAL HEX ( ps) PLATFORM SHIFT PRESERVATION OF BONE NEVER LOOKED BETTER
INTERNAL HEX ( ps) PRESERVATION OF BONE NEVER LOOKED BETTER infinite opportunities in implantology For almost 50 years ACE Surgical has been dedicated to dental surgical advancements. We continue to develop
More informationOPENING MINDS AND EXPANDING PRACTICE REVENUE OPPORTUNITIES
GIVE YOUR PATIENTS THE FREEDOM TO EAT, SPEAK AND LAUGH AGAIN. OPENING MINDS AND EXPANDING PRACTICE REVENUE OPPORTUNITIES Since the McGill Consensus in 2002, the dental industry has recognized that implant-supported
More informationcement-retained crown using the Laser-Lok Easy Ti temp abutment and PEEK plastic sleeves
cement-retained crown using the Laser-Lok Easy Ti temp abutment and PEEK plastic sleeves temporary restorations cement-retained crown using the Laser-Lok Easy Ti temp abutment and PEEK plastic sleeves
More informationOCTAGON BONE LEVEL Implant System
CGN BNE EVE Implant System www.infinitydentalimplant.com he infinity CGN Dental Implant System delivers a truly compatible, functional and aesthetic dental implant solution for you and your patients. he
More informationFOR PROFESSIONALS. Product Catalogue. Cochlear Vistafix 3 System A BONE ANCHORED PROSTHETIC SOLUTION
FOR PROFESSIONALS Product Catalogue Cochlear Vistafix 3 System A BONE ANCHORED PROSTHETIC SOLUTION 1 The Vistafix 3 System consists of: Cochlear Vistafix VXI300 Implant (Vistafix 3 Implant) Cochlear Vistafix
More informationOPENING MINDS AND EXPANDING PRACTICE REVENUE OPPORTUNITIES
GIVE YOUR PATIENTS THE FREEDOM TO EAT, SPEAK AND LAUGH AGAIN. OPENING MINDS AND EXPANDING PRACTICE REVENUE OPPORTUNITIES Since the McGill Consensus in 2002, the dental industry has recognized that implant-supported
More informationHigh-end solution STEP-BY-STEP USER GUIDE
High-end solution STEP-BY-STEP USER GUIDE System Contents REAL TIME Restoration Guided Conical drill Multi-Unit abutment, Conical connection Guided kit for conical connection implant procedure C1 & V3
More informationIQ IMPLANTS Smart Choice PRODUCT C ATA L O G
IQ IMPLANTS Smart Choice PRODUCT C ATA L O G www.iqimplants.com info@iqimplants.com 2 TABLE OF CONTENTS GENERAL Company Profile 3 IMPLANTS 5 PROSTHETICS 13 TOOLS 27 3 COMPANY PROFILE IQ Implants Ltd. reflects
More informationUDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments
Indications Instructions The Locator Root Attachment is designed for use with overdentures or partial dentures, retained in whole or in part by endodontically treated roots in the mandibular or maxilla.
More informationNARROW DIAMETER implant
N NARROW IAMETER implant N Precision dental solutions C-Tech Implant is a dynamic company with aggressive growth, producing components and product lines primarily for dental implantology. International
More informationMulti-unit abutment hybrid or fixed-detachable screw-retained restoration
Multi-unit abutment hybrid or fixed-detachable screw-retained restoration Use this technique for the fabrication of a multiple unit implant-supported, screw-retained hybrid in a partially or fully edentulous
More informationRestoring Straumann implants. with Locator abutments.
Restoring Straumann implants with Locator abutments. 1 1 Straumann is the industrial partner of the ITI (International Team for Implantology) in the areas of research, development, and education. Contents.
More informationNobelReplace Conical Connection Product overview
NobelReplace Conical Connection Product overview High primary stability, even in compromised bone situations1 The tapered implant body is designed for high primary stability and is ideal for Immediate
More informationORTH easy. The Complete System for Cortical Anchorage. OrthoEasy Pins
ORTH easy The Complete System for Cortical Anchorage Pins ORTH easy - easy and economic. An innovative head and three colour coded lengths for all of your orthodontic anchorage needs. Transgingival conic
More informationQuick start Prosthetics
EN Quick start Prosthetics Easy and effective YELLOW PROSTHETIC PLATFORM QN CEMENTED RESTORATIONS ESTHETIC AUTMENTS OPEN TRAY POST IMPLANT ANALOG Indexed components with internal conical connection. 0.7
More informationProduct catalog. ASTRA TECH Implant System EV
Product catalog ASTRA TECH Implant System EV CONTENTS Overview Product overview 3.0 Product overview 3.6 6 Product overview.2 8 Product overview.8 10 Product overview 5. 12 OVERVIEW Surgery Implants OsseoSpeed
More informationsurgical and prosthetic options & impression technique overview
surgical and prosthetic options & impression technique overview surgical options Multiple surgical protocols are used to achieve the prosthetic outcome of choice. The technique selected may be dependent
More informationContinuing Education. Implant Prosthetics for the General Practice. Samuel M. Strong, DDS
Implant Prosthetics for the General Practice Samuel M. Strong, DDS We are pleased to offer you free CE in your Dentaltown Magazine! You can now read a CE article in the magazine and go online to www. to
More informationintroduction to BioHorizons prosthetics
to BioHorizons prosthetics why choose BioHorizons prosthetics? BioHorizons offers a broad array of abutments for a wide range of restorative applications and individual needs including the versatile 3inOne
More informationverification jig fabrication
verification jig fabrication full-arch restorations verification jig fabrication Use this technique to verify and achieve passive fitting metal framework for a bridge, hybrid prosthesis or for an overdenture
More informationInterActive TM System. Catalog
InterActive TM System Catalog Table of Contents Page # Implant Design 1 2-3 2 Implant Dimensions Impression Technique 3 4-5 Implant Details Selection Charts: Implants, Abutments, Components 10-11 6-7 8
More informationHex-Lock Abutment System. Restorative Manual
System Restorative Manual 32 Restorative options with s s are manufactured from titanium alloy and used as the support foundation for single- or multiple-unit cement-retained, partially edentulous fixed
More informationProduct Catalog. Others make Implants to sell... Tatum Surgical makes Implants to treat your Patients.
Product Catalog Others make Implants to sell... Tatum Surgical makes Implants to treat your Patients. Advantages of Tatum Implant System: 1. Only one surgical procedure is required to place and load the
More informationProduct Catalog. Since 1985» Simple. Predictable. Profitable.
Product Catalog Since 1985» Simple. Predictable. Profitable. 2010 11 Table of Contents Implants...1 Implants...3 Implant Level Impression Components...6 Abutments...7 Temporary Abutments...9 Healing Abutments...
More informationOpening minds and expanding practice revenue opportunities
GIVE YOUR PATIENTS THE FREEDOM TO EAT, SPEAK AND LAUGH AGAIN. Opening minds and expanding practice revenue opportunities Since the McGill Consensus in 2002, the dental industry has recognized that implant-supported
More informationNEODENT GUIDED SURGERY
NEODENT GUIDED SURGERY MANUAL Grand Morse Connection Helix Implant GRAND POSSIBILITIES WITH A LIMITLESS SOLUTION. GRAND MORSE NEODENT GUIDED SURGERY. 4 5 6 CONTENTS 1. CLINICAL STEP BY STEP OF GRAND
More informationProduct catalog. ASTRA TECH Implant System EV
Product catalog ASTRA TECH Implant System EV 2 CONTENTS Overview Product overview 3.0 4 Product overview 3.6 6 Product overview 4.2 8 Product overview 4.8 10 Product overview 5.4 12 OVERVIEW Surgery Implants
More informationSIMPLE INSERTION, NATURAL STABILITY. Self-cutting capacity in both directions Makes it possible to achieve high primary stability with low torque
JD EVOLUTION PLUS+ SIMPLE INSERTION, NATURAL STABILITY. FEATURES ADVANTAGES Internal hex connection with lead-in bevel, 100% compatible with Zimmer Screw-Vent The Connection is universally recognized by
More informationSmarter Thinking. Simpler Design. STAGE-1. Product catalog
Smarter Thinking. Simpler Design. STAGE-1 SC Product catalog table of contents The STAGE-1 System STAGE-1 System Overview & Prosthetic Tables 3 RBM Surface & Patented Implant Delivery System 4 Implants
More informationINTERNAL HEX Implant System
Dental Implant Systems INTERNAL HEX Implant System infinite OPPORTUNITIES IN IMPLANTOLOGY For over 50 years ACE Surgical has been dedicated to dental surgical advancements. We continue to develop and manufacture
More informationPROSTHETIC PROCEDURE for TS & GS Implant System
Edition 03/2012 Prosthetic Procedure for TS & GS Implant System PROSTHETIC PROCEDURE for TS & GS Implant System OSSTEM Germany GmbH Mergenthalerallee 25 D-65760 Eschborn Tel: +49 (0) 61 96 / 777 55-0 www.osstem.com
More information3M ESPE MDI. Mini Dental Implants. Quick Order Guide
3M ESPE MDI Mini Dental Implants Quick Order Guide MDI Prosthetic Flow Chart 1.8mm, 2.1mm & 2.4mm Implants with Collar without Collar Square Head with Collar Corresponds with Lab Analog LAOB Corresponds
More informationLOCATOR F-Tx FIXED ATTACHMENT SYSTEM
LOCATOR F-Tx FIXED ATTACHMENT SYSTEM U.S. RETAIL PRODUCT ORDERING INFORMATION AND PRICE LIST* *Products and pricing listed in this guide may not be available in all countries. ZEST DANVILLE MATERIALS PERIOSCOPY
More informationThe Uniti implant system is designed to be simple to learn and use. A seamless surgical protocol renders the system user friendly.
Surgical Manual The Uniti implant system is designed to be simple to learn and use. A seamless surgical protocol renders the system user friendly. For the experienced practitioner it will take no more
More informationPROSTHETIC COMPONENTS
MILO 3.0mm 3.0mm Ø MILO Implants Prosthetic Connection: Ø 1.8 mm O-Ball Lengths: 10, 11.5, 13, 15 & 17 mm. Surface treatment: Blasted + Progressively Acid Etched Titanium 3.0mm MILO Fine Pitch Implants
More informationAstra Tech Implant System. Manual and product catalog. Guided surgery. Computer guided implant treatment with the Astra Tech Implant System EV
Astra Tech Implant System Manual and product catalog Guided surgery Computer guided implant treatment with the Astra Tech Implant System EV Simplicity without compromise The design philosophy of the Astra
More informationscrew-retained crown using the Laser-Lok Easy Ti temp abutment
screw-retained crown using the Laser-Lok Easy Ti temp abutment temporary restorations screw-retained crown using the Laser-Lok Easy Ti temp abutment Use this technique for the fabrication of long-term
More informationBiomimetic PEARL. Product catalogue
Biomimetic PEARL Product catalogue PEARL is the AVINENT system of mini implants, an innovative product with unique features that aims to provide a quality alternative to what is available today as regards
More informationINTRODUCTION. Why Choose Cortex Prosthetics?
Prosthetic Manual 4 INDEX Introduction 6-14 Impression Techniques 15-29 Abutments Selection Handling 30-33 Temporary Restorations 34-38 Screw Reiained Restorations 39-52 Removable Restorations 53-63 5
More informationAnchorage system. tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282
tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282 266 . innovative comprehensive efficient. Dentaurum Online Shop shop.dentaurum.com