RAYHACK Radial Malunion Distraction System

Size: px
Start display at page:

Download "RAYHACK Radial Malunion Distraction System"

Transcription

1 RAYHACK Radial Malunion Distraction System SURGICAL TECHNIQUE Surgical Technique as described by John M. Rayhack, MD

2 RAYHACK Radial Malunion Distraction System Surgical Technique Indicated for use in severe radial malunions, the Rayhack Radial Malunion Distraction System utilizes a multi-plane distractor which controls the distal fragment with the plate already in place. A multi-angled drill guide facilitates correction of pronation or supination deformities, and radial or ulnar translation is easily corrected. The narrow plate width minimizes tendon and soft-tissue irritation. Bone graft may be compressed to secure placement.

3 Contents Chapter 1 5 The Components Chapter 2 9 RAYHACK Radial Malunion Distraction System Surgical Technique STEP 1 - Surgical Approach - Trimming Lister s Tubercle - Preliminary Placement of the Saw Guide Base and Multi-Angled Drill Guide 10 STEP 2 - Drilling the.062 K-Wire - Drilling the Two Saw Guide Base Holes - Temporarily Removing the.062 K-Wire - Drilling the Distal Ulnar Fixation Hole 11 STEP 3 - Remove the Drill Guide and X-ray Confirmation of the Fixation Screw Hole - Performing the Osteotomy - Dilemma of the Dorsally-Translated Radius Fracture - Dilemma of the Distal Radius Non-Union 12 STEP 4 - Reapply the Multi-Angled Drill Guide and Replace the.062 K-Wire - Measuring and Tapping the Distal Ulnar Fixation Hole - Trimming the Diaphyseal Fragment - Removal of the Saw Guide 13 STEP 5 - Trimming the Dorsal Radial Metaphysis - Application of the Plate Over the K-Wire - Distractor Application - Fixation of the Distractor and Plate with Temporary Screws 14 STEP 6 - Application of the Long Ulnar Fixation Screw - Drilling the Radial Fixation Hole - Linear Distraction of the Osteotomy Proper surgical procedures and techniques are the responsibility of the medical professional. The following guidelines are furnished for information purposes only. Each surgeon must evaluate the appropriateness of the procedures based on his or her personal medical training and experience. Prior to use of the system, the surgeon should refer to the product package insert for complete warnings, precautions, indications, contraindications and adverse effects. Package inserts are also available by contacting Wright Medical Technology, Inc.

4 15 STEP 7 - Adding Additional Bone Screw A - Maximal Safe Osteotomy Distraction 16 STEP 8 - Caution: Binding of the Ball and Socket Mechanism - Gaining Radial Length Preferentially 17 STEP 9 - Gaining Ulnar Length Preferentially - Gaining Additional Volar or Dorsal Tilt - Check X-Rays 18 STEP 10 - Insertion of the Cortical-Cancellous Bone Graft - Minimal Compression of the Bone Graft after Insertion - Radial Screw Application 19 STEP 11 - Ulnar Screw Application - Proximal Screw Application - Round Hole Screw R Application - Self-Tapping Screws 20 STEP 12 - Final Fixation of Screws in the Slotted Plate/Distractor Removal - Optional Screw B in the Proximal Elongated Slot - K-Wire Fixation of the Bone Graft - Volar Translation of the Distal Fragment - Additional Cancellous Bone Graft and Wound Closure 21 STEP 13 - Post-Operative Immobilization - Delayed Unions, Non-Unions, Plate Breakage - Prophylactic Carpal Tunnel and Guyon s Canal Release Appendix 1 22 RAYHACK Radial Malunion Distraction System Instrumentation Appendix 2 23 Ordering Information

5 The Components chapter 1 FIGURE 1 Positioning Holes (Proximal) Preferred #1 #2 Radial Distraction Saw and Drill Guide Base The saw guide base serves as a template for two holes (#1 and #2) numbered from distal to proximal through which the saw guide, radial distractor and bone plate will be secured to the radius. Two sets of five transverse positioning holes will allow the secure temporary fixation of the multi-angled drill guide to the saw guide base. Proximal (preferred) or distal placement and specific increments of medial or lateral translation can be chosen depending on the position of the distal radial malunion fragment relative to the diaphysis. The distal positioning holes are only used in the rare case of excessive volar tilt of the distal radius in order to avoid drilling the fixation holes into the osteotomy site. Figure 1 The Saw Guide Osteotomy Attachment The saw guide attachment contains 5 prongs to allow positioning on the saw guide base. Osteotomy angles of 0, 10, 20, and 30 degrees are possible with this attachment. The saw guide attachment can be shifted laterally or medially to permit osteotomies of translated radial malunions. Figure 2 FIGURE 2 Degrees of Lateral Tilt Correction Multi-Angled Drill Guide The multi-angled drill guide allows fixation drill holes to be made into the distal radial fragment from +30 degrees proximally to -30 degrees distally at 5 degree increments. These 13 drill holes will permit up to the first 30 degrees of volar or dorsal correction of the articular surface in either volar or dorsal directions. For example: If the radial articular surface is dorsally angulated 20 degrees and 0 degrees of volar tilt is needed upon final correction, the +20 degree holes will be used for drilling the fixation holes with the multi-angled drill guide in the distal radius. In volarly-angulated fracture malunions, the -5 to -30 degree holes will be used. If the radius is too narrow to permit firm placement of these fixation holes, this system will not be suitable for use. Figure 3 FIGURE 3 Chapter 1 The Components 5

6 FIGURE 4 FIGURE 5 Set Screw Drill guide translated radially by 9mm (three prongs seated).062 K-Wire Holes Between each set of 2.5mm holes in the drill guide is a corresponding hole for a.062 inch K-wire for all 13 sets of holes in the drill guide. This.062 K-wire will be used to provisionally fix the multi-angled drill guide during drilling of screws #1 and #2. It will also align the distal fragment vertically for application of the fixation screws during placement of the distractor, and help to trim the dorsal cortical fragment to assure a tangential bone surface. Figure 4 Supination and Pronation Correction (Rotation mechanism of the drill guide.) In rare instances, the distal fragment has healed in a pronated or supinated position. It is possible to correct this rotational deformity through the use of a rotation mechanism, built into the drill guide. The set screw can be loosened (counter-clockwise) by a standard 2.5mm hex screw driver and the guide can be rotated to the side and relocked into position with the set screw. Up to 15 degrees of rotational correction in both directions is possible with this device but it is suggested to make only minimal corrections to avoid overly complicating the procedure. The degrees of angulation are marked on the semi-circular distal portion of the drill guide in 5 degree increments. Usually this will be set at 0 degrees unless modification of angulation is needed. Figure 5 EXAMPLE: If the radius is supinated 5 degrees, the guide should be set in a supinated position relative to the proximal portion of the drill guide. The fixation holes are rotated 5 degrees in the coronal plane (a plane running from dorsal to volar and medial to lateral). Once the osteotomy is completed and the distractor is applied, these holes will be vertical and aligned equal distance from the midline, thus correcting the supination abnormality. Medial and Lateral Translational Deformity The 5 prongs of the multi-angled drill guide permit medial, lateral, proximal and distal placement of the multi-angled drill guide on the saw guide base. This option is to correct any displacement of the distal radial fragment which may have healed in translated position relative to the shaft. Shift the 5 prongs medially or laterally by one, two, or three holes. This will allow placement of the fixation holes into the distal radial fragment. Each hole that is shifted represents a 4.5mm translation. Figure 6 At least two prongs of the multi-angled drill guide must be seated in two of the saw guide base holes. Once the osteotomy is performed, manually shift the fragment in the desired direction relative to the shaft. The multi-plane distractor holes are aligned by inserting the long cortical fixation screws into the distal radial holes. This will correct the original translation. If no translational correction is indicated, all 5 prongs of the drill guide should be seated into the 5 saw guide holes. FIGURE 6 6 Chapter 1 The Components

7 Distal slot Double-Slotted Radial Distraction Plate Distal holes FIGURE 7 Round holes Proximal slot The radial distraction plate features a low-profile distal portion with three round screw holes, a round hole in the middle and two slotted holes proximally. It is only available in stainless steel. Figure 7 In this procedure the plate is to remain flat and is not to be contoured. The implant provided in the set is shipped non-sterile and must be appropriately sterilized prior to the procedure. This is also true for the tray and all the additional equipment in the set. The saw blade is packaged in a sterile pouch. RAYHACK Radial Distractor 10mm FIGURE 8 The distractor allows the surgeon to gain length and to correct angulatory deformities in both PA and lateral planes. Two 10mm screw columns in the distal aspect of the distractor allow long fixation screws to control the distal fragment. The distractor straddles the plate and uses the same two screw holes for fixation in the radial diaphysis as the previously placed saw guide base. (These screws pass through the distractor, and the slots in the plate permit the plate to move distally during distraction, while the distractor remains in its original position.) Three ball and socket mechanisms permit the concurrent correction of multiple deformities. Radial inclination correction will be accomplished using preferential distraction of the screws on the radial side once the final length is achieved. The same distractor is used for both left and right radii. Compression of the cortical cancellous bone graft is accomplished at the completion of the procedure by one half counterclockwise turn of all three adjusting screws. Figure 8 Chapter 1 The Components 7

8 How Much Correction is Possible with this System? FIGURE 9 16mm 1 2 In the maximum safe distraction of this system, screw #1 will start at the distal end of the middle slot and end in the proximal aspect. This represents approximately 16mm of displacement. In a dorsally angulated radius which has been corrected, this measurement of 16mm represents the distance between the dorsal cortices of the diaphysis and the distal radial fragment. Due to angular correction, the volar cortical distance will be significantly less than16mm (this assumes a transverse osteotomy). This amount of distraction allows the round hole in the plate to fix to the diaphysis within the recommended limit of this system. In lieu of further distraction the surgeon should consider a concurrent ulnar shortening, after correction of all other parameters has occurred within the safe limit of this system. Figure 9 Note: Ulnar shortening equipment should be ordered in addition to the radial malunion distraction system. Additional Equipment Needed to Complete Procedure A Hall /LINVATEC, Microaire mount sagittal saw is required to use the specialized saw blade for the osteotomy. 8 Chapter 1 The Components

9 RAYHACK Radial Malunion Distraction System Surgical Technique chapter 12 Trim FIGURE 1 Degrees of Lateral Tilt Correction 1cm STEP 1 - Surgical Approach A dorsal linear incision (about 13-15cm) is used for the approach. This requires considerable exposure and the EPL and strap muscles will need to be retracted throughout the procedure. Open the capsule of the radial carpal articulation to identify the position and quality of the articular surface. The skin incision should not extend distally past the radial-carpal articulation but should allow this articulation to be examined intraoperatively. The fascia over the strap muscles should be adequately released. Trimming Lister s Tubercle Lister s tubercle should be shaved flat. A smooth dorsal surface of the radius is necessary to allow placement of the template and bone plate. This surface is prepared at the beginning of the procedure before preliminary placement of the saw guide and plate template. Failure to shave this area flat may result in a distal plate area which is not flush with the dorsal radius during final screw fixation. This is critical. After the osteotomy is performed, it may be necessary to trim the dorsal aspect of the distal fragment for the plate to lie flat on the radius. Unless this is performed the distal radius may be volarly displaced, thus minimizing bone-plate contact. Figure 1 Preliminary Placement of the Saw Guide Base and Multi-Angled Drill Guide FIGURE 2 Note: This is the most critical step in the entire procedure. Attach the multi-angled drill guide to the saw guide in the desired two to five holes to correct any translational deformity. If any pronation or supination deformity is present, the drill guide is set to the appropriate degrees of rotational correction. Manually hold the saw guide and attach the multi-angled drill guide on the dorsal radius. FIGURE 2 Before any screw holes are drilled into the radius to fix the saw guide base, open the radial carpal articulation and assure a distance of 1cm from the radial-lunate joint to the template. Insert the two 2.5mm drill bits through the multi-angled drill guide and ensure the drill bits make good contact with the distal radial fragment. Make sure the fixation holes are not placed too far distally. Apply the template against these drill bits. Align the ulnar 2.5mm drill bit as far to the ulnar side as possible. It is recommended that the distal radial articular surface is placed in a neutral lateral tilt of the distal radial articular surface. This will leave some margin for any loss of volar tilt correction that occurs in the post-operative period and will diminish the amount of bone trimming necessary on the dorsal radial metaphyseal surface. Chapter 2 Rayhack Radial Malunion Distraction System Surgical Technique 9

10 Degrees of Lateral Tilt Correction FIGURE 3 FIGURE 4 #1 #2 STEP 2 - Drilling the.062 K-Wire Drill a.062 K-wire in the angulated hole corresponding to the same degree of lateral tilt correction* chosen for the 2.5mm fixation holes. Drill through both cortices. This will help to hold the entire apparatus in position until the screws are inserted into the saw guide base. FIGURE 3 *Aim for neutral articular tilt on the lateral projection. Drilling the Two Saw Guide Base Holes The proximal screw hole (#2) is drilled through the saw guide using a 2.5mm drill bit and the handheld drill guide. Prior to drilling, ensure the saw guide is positioned properly on the radial shaft. Measure and tap using a 3.5mm tap. Many surgeons will add 2mm to the length of this screw as these screws will ultimately fix the bone plate. Do not be overly concerned about this additional length of screw protruding into the pronator quadratus muscle. This decision is used with discretion. Once the appropriate sized proximal screw is applied, the distal screw hole #1 is drilled, measured, tapped and the screw (also possibly 2mm longer) is applied. FIGURE 4 Over-tightening these screws may strip the hex socket in the screw head upon later screw removal. The same two screw holes that fix the saw guide to the radial diaphysis will ultimately be used to fix the radial distractor and the bone plate to the radius. Temporarily Remove the.062 K-Wire Temporarily remove the K-wire to allow unobstructed access to drill the ulnar fixation hole through the desired angulation hole. Degrees of Lateral Tilt Correction Drilling the Distal Ulnar Fixation Hole through the Multi-Angled Drill Guide The drill bit is now drilled into the ulnar side of the distal radial fragment at the chosen degree of angulation. Confirm the drill bit is not glancing off the radius. Drill this hole with a 2.5mm drill bit through both cortices. The screw hole has been converged 5 degrees toward the midline in order to avoid interference with the radial cortex, but not enough to converge and hit the opposite fixation screw. Long cortical screws placed through the distractor and into this fixation hole will later press against the ulnar flared portion of the plate and will help push the plate distally during the distraction. FIGURE 5 FIGURE 5 10 Chapter 2 Rayhack Radial Malunion Distraction System Surgical Technique

11 STEP 3 - Remove the Drill Guide - X-Ray Confirmation of the Position of the Fixation Screw Hole Remove the drill guide by gently pulling perpendicular to the axis of the five drill guide holes. Take a postero anterior X-ray with the ulnar fixation hole drilled, the drill guide removed, and the saw-guide base still attached. Confirm the intended location of the fixation hole has been obtained for the plate to be appropriately positioned and not placed too far distally. If there is an error, reposition the saw guide base and re-drill the ulnar 2.5mm hole. This is a critical confirmatory step! FIGURE 6 FIGURE 7 Undesired Performing the Osteotomy Apply the saw guide attachment and choose an osteotomy of 0, 10, 20, or 30 degrees. Use only the saw blade provided as it coordinates with the width of the radius and the saw guide cutting slot. The dimensions of this blade permit use of a Hall /LINVATEC or Microaire mount sagittal saws. Use a gentle side-to-side motion and cool with slush saline during this procedure to minimize bone necrosis. Protect the soft tissues on all sides of the radius with a standard retractor to avoid soft tissue damage. FIGURE 6 The radial osteotomy may be freehanded at any location or angulation desired but must not compromise the angled distal radial fixation holes or hole #1 of the saw guide base. Using the 0 degree vertical hole (recommended) will minimize later metaphyseal trimming. Dilemma of the Dorsally-Translated Radius Fracture (Lateral Projection) In cases in which the radius has healed in a dorsally translated position, it is tempting to perform the osteotomy at the site of the original fracture. However, this must allow sufficient space for placement of the 2.5mm fixation holes into the distal fragment. If the fracture has occurred in a very distal position, it will be impossible to osteotomize the radius; as there needs to be sufficient area to affix the plate to the distal radius without being placed too far distally. Attempts to make the osteotomy more proximal will leave a stepped distal radius which may be unacceptable. Additionally, there may be insufficient space for placement of the fixation screw holes. Under these circumstances, the procedure may not be able to be performed with this system. FIGURE 7 Dilemma of the Distal Radial Non-Union (Non-Translated) If the radius is fractured at this distal location but not translated as discussed above and healing has not yet occurred, there will be insufficient space for the fixation screws. It is advisable to await fracture healing before a more proximal osteotomy is performed in order to allow for sufficient space for the fixation holes. Chapter 2 Rayhack Radial Malunion Distraction System Surgical Technique 11

12 FIGURE 8 FIGURE 9 Trim STEP 4 - Reapply the Multi-Angled Drill Guide and Replace the.062 K-Wire After the ulnar 2.5mm drill bit fixation hole is drilled, the.062 K-wire is reinserted through the previously drilled hole in the distal radius. Since the osteotomy has been performed, it will be necessary to hold the radius in its original position during reinsertion. Apply the drill guide to assure placement in the original hole. Measuring and Tapping the Distal Ulnar Fixation Hole Measure and record the depth of the ulnar distal fixation hole. This ulnar hole was drilled at a complex angle and the depth gauge will also be angled into the hole. Hold the K-wire vertically to help align the tap with this hole. Record this length and tap this hole with a 3.5mm tap. FIGURE 8 Trimming the Diaphyseal Fragment While holding the K-wire vertical, trim any diaphyseal fragment that projects above the plane of the distal radius. This allows the plate to lie flush on the dorsal radial surface. Always trim more rather than less of the triangular fragment. Failure to do so will result in loss of volar tilt correction when the three distal plate screws are finally tightened. If removal of cortical bone down to cancellous bone is necessary for the plate to lie flush with the base at this limited area, it should be performed. This is a non-critical area for stability of the construct once grafting has been performed. FIGURE 9 Removal of the Saw Guide Carefully remove screws #1 and #2 from the saw guide base and place the screws in the corresponding temporary holding slots in the tray. These screws will be used at the end of the procedure to replace the tem porary longer screws in holes #1 and #2 when the distractor is removed. When removing the screws, be careful not to strip the hex head as this will require a lengthy delay to remove the head with screw removal instrumentation. Ensure no debris is in the screw head hex hole by fully seating the screwdriver and applying counter-traction to the forearm while the screw is turning in a counter-clockwise direction. Stripping of this screw head and its ultimate removal also risks damage to the saw guide base. FIGURE 10 Tray Slots #1 #2 #3 #4 FIGURE Chapter 2 Rayhack Radial Malunion Distraction System Surgical Technique

13 FIGURE 11 FIGURE 12 Round Hole of Distractor Optional Trimming Distractor Slot #1 #2 STEP 5 - Trimming the Dorsal Radial Metaphysis It may be necessary to remove the distractor and plate to trim additional bone to avoid any space between the radius and the distractor plate. This is especially apparent if additional volar or dorsal tilt correction is performed using the precision distraction feature. Most of the volar or dorsal correction should be achieved previously by choosing the appropriately angled fixation holes to be drilled through the drill guide. It is important to keep the plate flush against the bone distally where the three cortical screws are applied. Some space between the plate and bone, proximal to the distal three screws, is desirable superior to this distal fragment provided that the distal plate-bone contact area is flush. FIGURE 11 If this space is not adequate and a dorsal diaphyseal spike impinges on the plate, the distal fragment may angulate dorsally once the three distal screws are tightened and the desired correction could be lost. Use cancellous bone graft for any bone defects below the plate. Application of the Plate Over the K-Wire Do Not Bend or Contour the STAINLESS STEEL Plate Place the most proximal of the three distal screw holes of the flared end of the radial distractor plate over the.062 K-wire. With the plate held in place, assure a flush surface with the distal radial fragment. Hold the K-wire vertically and trim additional bone as indicated. FIGURE 12 Distractor Application Prior to application, separate the two vertical columns of the distractor by approximately 7mm. Apply the precision distractor over the plate. Longitudinal ridges on the under surface of the distractor straddle the radial plate. Fixation of the Distractor and Plate to the Diaphysis with Temporary Screws that are 4mm Longer Choose a 2.5mm screw which is 4mm longer than screw #1 and place it through the distractor, the middle plate slot, and then into the most distal radial diaphyseal hole. This holds the plate and the distractor concurrently. This will also be done for screw #2. These two screws (#1 and #2) should not be excessively tightened. FIGURE 13 Screw #1 will pass through the round hole of the distractor and the middle oblong slot in the distractor plate. Screw #2 will be placed through the slot of the distractor and in the distal end of the proximal oblong slot in the plate. FIGURE 13 Chapter 2 Rayhack Radial Malunion Distraction System Surgical Technique 13

14 STEP 6 - Application of the Long Ulnar Fixation Screw 14mm 4mm Correct Position Avoid This Volar Translation Place a 3.5mm x 36mm cortical screw, provided in the kit, through the ulnar distal hole of the distractor and into the pre-drilled and tapped ulnar fixation hole of the distal radial fragment. The reason for this seemingly excessive length is as follows: the column of the distal portion of the distractor accounts for 10mm of this length and there may be approximately 4mm between the bone and the under surface of this distractor. This is added to the original length of the fixation holes drilled into the distal radial fragment and measured and tapped previously. Hold the distal fragment against the plate to avoid any volar translation. Manually line up the ulnar fixation hole with the distractor by looking down the 10mm fixation column of the distractor. Hold the.062 K-wire vertically to align the fixation column with the ulnar hole in the distal fragment. Gently distract or compress the adjusting screws to permit the lining up process. If difficulty is still encountered, loosen screws #1 and #2 holding the distractor to the plate and bone to allow more play to assist alignment. Once applied, retighten screws #1 and #2. FIGURE 14 FIGURE 14 Drilling the Radial Fixation Hole If additional radial inclination on the PA is anticipated in excess of 15 degrees, use a laminar spreader or Freer elevator to gently distract the radial side of the osteotomy before drilling this radial distractor hole. Ensure the drill bit will engage the distal radial fragment. FIGURE 15 Place the attached distractor into the radial distractor hole and drill hole with a 2.5mm drill bit. Measure, tap, and insert a 3.5mm screw into this hole. Re-tighten these screws prior to distraction. It is imperative that the distal fragment is held to the plate when applying these screws or the distal fragment will be translated volarly from the plate. Do not over-tighten the fixation screws. The 10mm column length of metal in the distractor keeps the fixation screws vertical and corrects the volar or dorsal tilt from its pre-drilled angular position in the distal radial fragment. Remove the.062 K-wire. FIGURE 15 Linear Distraction of the Osteotomy Gently use the screwdriver and gradually distract the three adjusting screws in the compression-distraction device an equal amount. Distract the bottom screw first. Important: first correct the desired length. Initially, all screws should be distracted an equal amount. Avoid excessive force as the adjusting screw heads may strip or the cortical bone could break at the point of application of the 3.5mm distraction screws. FIGURE 16 FIGURE Chapter 2 Rayhack Radial Malunion Distraction System Surgical Technique

15 FIGURE 17 Screw A Screw #1 #2 STEP 7 - Adding an Additional Bone Screw A Proximal to the Round Hole in the Plate As additional distraction occurs, the distal portion of the middle elongated slot in the plate will appear distal to the round hole in the distractor. Use the handheld drill guide to drill an additional hole through the plate. This will be approximately 8-11mm distal to screw #1. This screw must be kept slightly loose so it is recommended to add 2mm to the depth gauge measurement. This screw will help to avoid separation (dorsally) of the plate from the bone as additional distraction occurs. Screw A will not engage the distractor, just the bone plate. Do not over tighten this screw. If only minimal distraction occurs in the procedure, there may not be an opportunity to place this screw in the distal portion of the middle slot due to insufficient space distal to screw #1. FIGURE 17 At the completion of the distraction of the osteotomy, space may be available to place an additional screw B in the distal portion of the proximal slot. Use the handheld drill guide when drilling the hole. Maximal Safe Osteotomy Distraction FIGURE 18 Round Hole Screw R A 1 5mm 2 Eventually, the distraction may reach the point where the round hole (screw R ) in the plate (distal to the long slot) is about 5mm proximal to the proximal radial cut surface. Once this screw is applied, the plate cannot slide proximally. If the round hole is distal to the osteotomy, the only holes fixing the plate are the two slotted holes and proximal plate slippage could occur. It is important to assure the round hole for screw R (between the middle slot and the solid portion of the plate) permits secure cortical fixation on the proximal diaphysis. In lieu of further distraction, correct the radial styloid angulation, translation, dorsal or volar tilt, any pronation or supination deformity, and consider a concurrent ulnar shortening procedure. This will minimize tension on the system during excessive distraction and diminish the healing time necessary for incorporation of the bone graft. FIGURE 18 Note: Ulnar shortening equipment should be ordered in addition to the Radial Malunion Distraction system. Chapter 2 Rayhack Radial Malunion Distraction System Surgical Technique 15

16 FIGURE 19 STEP 8 - Caution: Binding of the Ball and Socket Mechanism The ball and socket is designed to assist in placing the distal fragment of the radius in a desired position relative to the diaphysis. There is a limit to the amount of distraction, and concurrent angulation in three planes that this system can tolerate. The linear distraction itself places a considerable amount of tension on the system. Additional angulation of the distal fragment, as seen in the next three steps, by clockwise rotation of the adjusting screw on one side and counter-clockwise rotation of the adjusting screws on the other side will add to the total tension on the system. Most of the volar and dorsal tilt correction should have been achieved by the use of the appropriate angled holes in the multi-angled drill guide. Do not rely on the distractor to any great extent to control volar and dorsal tilt correction. Attention to this detail will limit the overall stress on the ball and socket mechanism and perhaps more importantly, obviate the need for additional trimming of the dorsal diaphyseal lip to permit the plate to sit flush on the radius. Avoid excessive stressing of the intended limits of this device. This limit will be perceived in the amount of torque required to tighten the adjusting screws. Damage to the adjusting screws or distractor could prevent use of this equipment in order to complete the procedure. If excessive resistance is perceived, assure the long fixation screws are not too tight thus preventing manipulation of the distal radial fragment. Consider additional soft tissue release and allow creep to occur while the bone graft is procured and then an additional attempt may be made. If it is still too tight to manipulate the distal radial fragment, a concurrent ulnar shortening may be appropriate. Always correct length before attempting angulatory corrections. FIGURE 19 Gaining Radial Length Preferentially It is possible to angulate the radial side more than the ulnar side by tightening the radial adjusting screw(s) clockwise (lengthening) and slightly turning the ulnar screw(s) counter-clockwise (shortening). The right and left radii will have two adjusting screws (top and bottom) on the ulnar side for the left wrist and on the radial side for the right wrist. Avoid correcting one screw on the double-adjusting screw side more than the other or an unwanted volar or dorsal tilt may occur. However, this may be desired as seen in Figure 22. With significant radial styloid length adjustment, the distal portion of the plate may approach the radial lunate articulation on the ulnar side. It should not surpass this articulation and can be clinically confirmed by observing the articular surfaces. FIGURE 20 FIGURE Chapter 2 Rayhack Radial Malunion Distraction System Surgical Technique

17 FIGURE 21 FIGURE 22 STEP 9 - Gaining Ulnar Length Preferentially It is possible to angulate the ulnar side more than the radial side by turning the ulnar adjusting screw(s) clockwise (lengthening) and slightly turning the radial screw(s) counter-clockwise (shortening). The right and left radii will have the two side-adjusting screws (top and bottom) on the ulnar side for the left wrist and on the radial side for the right wrist. Avoid correcting one screw on the double-adjusting screw side more than the other or an unwanted volar or dorsal tilt may occur. However, this may be desired as seen in the next step below. FIGURE 21 Gaining Additional Volar or Dorsal Tilt It is possible to fine tune the correction of volar and dorsal tilt to some degree through the preferential lengthening and shortening of the top and bottom adjusting screws on the same side of the distractor. Most of this correction should have occurred earlier by choosing the appropriately angled-fixation drill holes in the distal radius at the beginning of the procedure (Figure 3). In the example shown, some dorsal tilt is accomplished by clockwise rotation of the bottom adjusting screw. Additional dorsal correction may be accomplished by clockwise rotation of the bottom adjusting screw or concurrent counter-clockwise rotation of the top two adjusting screws an equal amount. If additional volar tilt is required, confirm the plate lies flush on the radius distally and the dorsal diaphyseal lip is adequately trimmed. FIGURE 22 Check X-Rays After distraction and angular corrections are achieved, take X-rays to confirm the position of the distal radial fragment in both PA and Lateral projections. Compare with the scout films of the non-affected extremity to approach an anatomical correction. This may be simplified by image intensification or fluoroscopy as opposed to plain films. The equipment is designed to permit unobstructed view of the distal radial articular surface in both the PA and Lateral projections. The long 3.5mm cortical fixation screws in the distal radial fragment (outside the plate in the distractor) are tightened at this point (prior to the X-rays). Tightening the three screws through the plate proximal to the osteotomy ( A, #1, #2) is also advisable. This will permit an accurate representation of the final bone position before the distal three cortical bone screws and the round hole screw R in the plate proximal to the osteotomy are drilled, tapped, and inserted. If further angular or length correction adjustment is needed, it is imperative to again loosen these screws slightly to permit plate gliding. If the dorsal metaphyseal spike has not been trimmed sufficiently, dorsal angulation may occur as these screws are tightened. If necessary, remove the distractor and perform additional bone trimming of the dorsal-diaphyseal spike (FIGURE 9). Chapter 2 Rayhack Radial Malunion Distraction System Surgical Technique 17

18 FIGURE 23 Trim STEP 10 - Insertion of the Cortical-Cancellous Bone Graft (and Additional Cancellous Bone Graft) Cut a tricortical bone graft and make sure it is trimmed and wedged in securely (especially volarly) to assure that no collapse of the distal fragment occurs. This is critical and failure to do so may cause the three distal radial screws to angulate in the holes of the plate due to the small amount of plate-screw contact. Purely cancellous bone graft (without the cortical-cancellous bone graft) is not recommended unless cortical contact is assured on the volar cortex (opposite the plate). Use the thick portion of the iliac crest 2 to 3 inches lateral to the anterior-superior iliac spine for harvesting. Placing the superior crest volarly, the inner and outer iliac tables medially and laterally, and the cancellous cut surfaces proximally and distally, is recommend ed. In most instances the cortical-cancellous bone graft may be inserted from the radial side and placed under the plate. Trim the volar triangular cortical margins to create a more reliable contact surface for insertion of the bone graft. Trimming can also be performed on the distal fragment if necessary to assure vertical surfaces for the bone graft. FIGURE 23 Alternative Bone Grafts: Synthetic bone graft substitutes are not recommended. Composite bone graft substitutes with DBM may be used, but rigid fixation is key. Minimal Compression of the Bone Graft after Insertion The two long, distal cortical fixation screws in the compression device are situated proximal to the flare of the radial distraction plate. They effectively push the plate distally with gradual distraction of the adjusting screws. A small amount of compression of the graft can be performed once the graft is inserted. This is accomplished by one half to one full counter-clockwise turn of all three adjusting screws an equal amount. The plate may need to be tapped proximally due to being pushed into a more distal position by the long distal fixation screws during distraction. Radial Screw Application Use the 2.5mm drill bit and handheld drill guide to insert the two most distal screws. The intent to ASSURE DIVER GENCE. Direct the radial screw 5 degrees radially. FIGURE 24 FIGURE Chapter 2 Rayhack Radial Malunion Distraction System Surgical Technique

19 STEP 11 - Ulnar Screw Application Direct the ulnar distal screw ulnarly at 5 degrees. Ensure the distal radial ulnar and radial carpal joints are free of any screw intrusion. Visualize the radial carpal joint surfaces to assure appropriate screw placement. FIGURE 25 FIGURE 25 FIGURE 26 FIGURE 27 Proximal Screw Application The most proximal of these three screws is directed proximally by 5 degrees. Thus, a tripod fixation of the distal radius will occur by these distal three screws. Note excessive angulation (>5 degrees) of the screws could cause the screw heads to become prominent and could cause undesired tendon or soft tissue irritation. The plate is designed to fully seat the screw heads to avoid tendon irritation. With significant angulation of the distal fragment (gaining radial styloid length for example), it may not be possible to apply the third screw (the first screw distal to the osteotomy) until after the radial distractor has been removed. This is due to the fact that the distractor may block access to the bone plate screw hole. It is unlikely that any loss of fixation will occur before the final screw is inserted, however, do not manipulate the radius until the third screw is inserted and all proximal screws through the round hole and two long slots have been inserted. FIGURES 26 and 27 Round Hole Screw R Application If a satisfactory position has been achieved, the round hole R in the plate is now drilled, measured, and tapped. The screw may be 2mm longer than the measurement to assure good bicortical fixation. Avoid undesired angulation of this screw into the osteotomy surface. FIGURE 28 Self-Tapping Screws (Not Recommended) Preference may be to use self-tapping screws in the three distal plate holes after drilling with the 2.5mm drill bit. Use of self-tapping screws throughout the procedure in which these same self-tapping screws are removed and replaced, may not preserve the integrity of the threaded holes and is not recommended. R FIGURE 28 Chapter 2 Rayhack Radial Malunion Distraction System Surgical Technique 19

20 FIGURE 29 FIGURE 30 FIGURE 31 R A 1 2 R A 1 B 2 K-wires R A 1 B 2 Screw Designations STEP 12 - Final Fixation of Screws in the Slotted-Plate/Distractor Removal Securely tighten screw R and screw A. Remove the distractor and replace screws #1 and #2 from the temporary holding slots in the tray. Replace these screws in their respective holes through the plate. Discard the temporary longer screws #1 and #2, and the excessively long fixation screws placed in the distractor, into an appropriate biohazardous container. A total of 4 screws are now in the diaphysis fixing the plate: one through the round hole R, two in the middle elongated slot (screw #1 and A ). Screw #1 will now be located in the proximal aspect of the middle slot of the plate, and screw A will be in the distal aspect of this middle slot. Screw #2 will now be located in the proximal aspect of the proximal slot of the plate. FIGURE 29 Optional Screw B in the Proximal Elongated Slot There may be room for an additional screw in the distal aspect of the proximal elongated slot distal to screw #2. Application of screw B is by surgeon discretion. Use a handheld drill guide to drill this 2.5mm hole. FIGURE 30 Ensure that all screws are securely tightened. K-Wire Fixation of the Bone Graft Insert K-wires in order to maintain secure fixation of the cortical graft to the diaphysis and distal radial fragment. FIGURE 31 (K-wires are not provided by Wright.) Volar Translation of the Distal Fragment (Possible Advantage) As viewed on the lateral projection, some volar translation or displacement of the distal radial fragment (relative to its anatomic position) will occur in most radial malunions treated with this system. The reason is the plate is straight (and should not be contoured) and the distal radial fragment lies under the plate. Additional trimming of the dorsal radial surface may translate this fragment dorsally relative to the shaft, however, this may weaken the screw contact point for the three distal plate screws. Since the distal fragment is slightly displaced volarly by the straight plate, its original axis may lie below the axis of the diaphysis. The lunate should remain properly aligned with the radial lunate fossa and no clinical deformity should be apparent. There may be less tendency for the extensor tendons to rub on the plate and it is conceivable that this volar displacement may be advantageous. Additional Cancellous Bone Graft and Wound Closure Prior to closing, add additional cancellous bone graft around the osteotomy to maximize chances for healing. Any defect between the plate and the bone should also be filled with autogenous cancellous bone graft. It is usually impossible to completely cover the plate with surrounding periosteum and capsule. A small portion of the extensor retinaculum may be used to assist in this partial plate coverage. 20 Chapter 2 Rayhack Radial Malunion Distraction System Surgical Technique

21 STEP 13 - Post-Operative Immobilization It is recommended that a long-arm, sugar-tong splint be applied at surgery. This should be converted to a long-arm cast for a minimum of 4-6 weeks post surgery or a volar-dorsal plaster splint in trustworthy patients. A short-arm cast may be applied earlier if the surgeon is assured that the patient will be sufficiently cautious to protect the construct until healing occurs. Eventually a thermoplastic splint may replace the short-arm cast until complete healing occurs. No activity against resistance should be allowed until complete osteotomy healing is assured. Patients felt to have reckless tendencies should be additionally protected. Delayed Unions, Non-Unions, Plate Breakage Due to the difficult nature of this procedure, a small percentage of cases may experience delayed unions or non-unions. The addition of abundant cancellous bone graft at the site of the cortical-cancellous bone graft may help to diminish the non-union rate. Delayed unions and non-unions need to be addressed by appropriate immobilization, external stimulation, or additional surgery before loss of bone fixation and/or plate breakage occurs. Prophylactic Carpal Tunnel and Guyon s Canal Release Lengthening the radius could precipitate median or ulnar nerve symptoms and surgeons should consider a prophylactic release of the carpal tunnel and Guyon s canal intraoperatively. Post-operative surveillance for these symptoms should be undertaken as well. Signs of soft tissue ischemia or necrosis due to excessive soft tissue stretching should also be closely monitored. Some surgeons may elect a concurrent ulnar shortening rather than to consider any excessive radial lengthening. Patients should be carefully counseled about these and other potential complications of this extremely difficult and often lengthy procedure prior to the surgical procedure. Chapter 2 Rayhack Radial Malunion Distraction System Surgical Technique 21

22 RAYHACK Headline Radial Headline Malunion Distraction Instrumentation 2.5 Handheld Drill Guide Multi-Angled Drill Guide 3.5mm Cortical Screws Saw Guide on Base Radial Distractor Screwdriver Shaft Screwdriver Handle Drill Bits and Taps Additional Radial Distractor Screws Radial Malunion Plate 2.7mm Cortical Screws Depth Gauge 22 Appendix 1 Rayhack Radial Malunion Distraction System Instrumentation

23 Ordering Information rayhack RADIAL MALUNION DISTRACTION SYSTEM CATALOG CATALOG DESCRIPTION no. No. 4020KITA 4021KITA* RAYHACK PLATE RAYHACK DIST SAW BLADE RAYHACK CORT SCR 3.5MM, 10MM RAYHACK CORT SCR 3.5MM, 12MM RAYHACK CORT SCR 3.5MM, 14MM RAYHACK CORT SCR 3.5MM, 16MM RAYHACK CORT SCR 3.5MM, 18MM RAYHACK CORT SCR 3.5MM, 20MM RAYHACK CORT SCR 3.5MM, 22MM RAYHACK CORT SCR 3.5MM, 24MM RAYHACK CORT SCR 2.7MM, 14MM RAYHACK CORT SCR 2.7MM, 16MM RAYHACK CORT SCR 2.7MM, 18MM RAYHACK CORT SCR 2.7MM, 20MM RAYHACK CORT SCR 2.7MM, 22MM RAYHACK CORT SCR 2.7MM, 24MM RAYHACK DRILL BIT 2.0MM RAYHACK DRILL BIT 2.5MM RAYHACK DRILL BIT 2.7MM *4021KITA US distribution only. 23

24 Headline Headline rayhack RADIAL MALUNION DISTRACTION SYSTEM CATALOG CATALOG DESCRIPTION no. No. 4020KIT1 4021KIT1* RAYHACK DRILL GUIDE RAYHACK DEPTH GAUGE RADIAL DISTRACTOR SAW GUIDE BASE RADIAL DISTRACTOR SAW GUIDE BLOCK RAYHACK DISTRACTION DEVICE RAYHACK CORTICAL SCREWS RAYHACK MULTI-PLANE DISTRACTOR RAYHACK BONE TAP 2.7MM RAYHACK BONE TAP 3.5MM RAYHACK SCREWDRIVER SHAFT RAYHACK SCREWDRIVER HANDLE *4021KIT1 US distribution only. 24

25

26

27

28 Wright Medical Technology, Inc Airline Road Arlington, TN phone toll-free Wright Medical EMEA Krijgsman DM Amstelveen The Netherlands Trademarks and Registered marks of Wright Medical Technology, Inc Wright Medical Technology, Inc. All Rights Reserved. SO

RAYHACK Kienbock Radial Shortening System

RAYHACK Kienbock Radial Shortening System RAYHACK Kienbock Radial Shortening System SURGICAL TECHNIQUE Surgical Technique as described by John M. Rayhack, MD RAYHACK Kienbock Radial Shortening System Surgical Technique Contents RAYHACK Kienbock

More information

RAYHACK OSTEOTOMY SYSTEMS. Indicated For Severe Radial Malunions RENTAL SETS AVAILABLE. Surgical Protocol 9/1/99. Revised 10/30/04

RAYHACK OSTEOTOMY SYSTEMS. Indicated For Severe Radial Malunions RENTAL SETS AVAILABLE. Surgical Protocol 9/1/99. Revised 10/30/04 RAYHACK RADIAL MALUNION DISTRACTION SYSTEM Revised 10/30/04 Indicated For Severe Radial Malunions RENTAL SETS AVAILABLE Drill Guide DEGREESOFLATERALTILT CORRECTION Distractor Saw Guide Base Saw Guide Double

More information

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation. Technique Guide LCP Small Fragment System Table of Contents Introduction

More information

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1) Distal Radius Plate Instrument and Implant Set Surgical Technique Discontinued December 2017 DSUS/TRM/0916/1063(1) The Distal Radius Plates Indications For fixation of fractures and osteotomies, including

More information

MICRONAIL. Intramedullary Distal Radius System SURGICAL TECHNIQUE

MICRONAIL. Intramedullary Distal Radius System SURGICAL TECHNIQUE MICRONAIL II Intramedullary Distal Radius System SURGICAL TECHNIQUE Contents Introduction 3 4 Chapter 1 5 Chapter 2 6 Appendix A 18 Appendix B 19 Surgeon Design Team Introduction Product Information Surgical

More information

Zimmer Small Fragment Universal Locking System. Surgical Technique

Zimmer Small Fragment Universal Locking System. Surgical Technique Zimmer Small Fragment Universal Locking System Surgical Technique Zimmer Small Fragment Universal Locking System 1 Zimmer Small Fragment Universal Locking System Surgical Technique Table of Contents Introduction

More information

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. Technique Guide 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. Table of Contents Introduction 2.4 mm Variable Angle LCP

More information

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system. Technique Guide 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system. Table of Contents Introduction 3.5 mm LCP Low Bend Medial Distal Tibia Plates

More information

The Wrist Fusion Set. Stainless Steel and Titanium TECHNIQUE GUIDE. Instruments and implants approved by the AO Foundation

The Wrist Fusion Set. Stainless Steel and Titanium TECHNIQUE GUIDE. Instruments and implants approved by the AO Foundation The Wrist Fusion Set Stainless Steel and Titanium TECHNIQUE GUIDE Instruments and implants approved by the AO Foundation Three Plate Options Stainless Steel or Titanium* Standard Bend Stainless Steel [242.510]

More information

OBSOLETED. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

OBSOLETED. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation. Surgical Technique LCP Small Fragment System This publication

More information

Distal Radius Plate 2.4/2.7 dorsal and volar

Distal Radius Plate 2.4/2.7 dorsal and volar Distal Radius Plate 2.4/2.7 dorsal and volar Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. Distal Radius Plate

More information

CHARLOTTE. Snap-Off Screws SURGICAL TECHNIQUE

CHARLOTTE. Snap-Off Screws SURGICAL TECHNIQUE CHARLOTTE Snap-Off Screws SURGICAL TECHNIQUE CHARLOTTE snap-off screws surgical technique SURGICAL ADVISORS ROBERT ANDERSON, MD BRUCE COHEN, MD W. HODGES DAVIS, MD Proper surgical procedures and techniques

More information

LCP Distal Humerus Plates

LCP Distal Humerus Plates The anatomic fixation system for the distal humerus with angular stability Surgical technique LCP Locking Compression Plate Contents Indications and contraindications 2 Implants 3 Instruments 5 Preparation

More information

Instrument and Implant for wrist fracture

Instrument and Implant for wrist fracture Instrument and Implant for wrist fracture Jansri Janpanya Product specialist The Bangkok Unitrade Co,.ltd. Objectives Type of LCP for distal radius Fx. The new LCP design for distal radius Fx. Have knowledge

More information

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System. Technique Guide LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System. Table of Contents Introduction Features and Benefits 2 AO ASIF Principles 4 Indications 5 Surgical

More information

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability. LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability. Technique Guide LCP Small Fragment System Table of Contents Introduction

More information

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. Technique Guide 2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. Table of Contents Introduction 2.4

More information

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system.

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system. Technique Guide 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system. Table of Contents Introduction 3.5 mm LCP Olecranon Plates 2 AO Principles 3 Indications 3 Clinical

More information

Surgical Technique Guide

Surgical Technique Guide Surgical Technique Guide Minimally Invasive, Intramedullary Device For Distal Radius Fragility Fractures The Sonoma WRx Wrist Fracture Repair Device is flexible, inserting easily through a small incision

More information

Long Volar Plates for Diaphyseal-Metaphyseal Radius Fractures LCP. Dia-Meta Volar Distal Radius Plates. Surgical Technique

Long Volar Plates for Diaphyseal-Metaphyseal Radius Fractures LCP. Dia-Meta Volar Distal Radius Plates. Surgical Technique Long Volar Plates for Diaphyseal-Metaphyseal Radius Fractures LCP Dia-Meta Volar Distal Radius Plates Surgical Technique Table of Contents Introduction LCP Dia-Meta Volar Distal Radius Plates 2 AO Principles

More information

DARCO. LPS Plate SURGICAL TECHNIQUE

DARCO. LPS Plate SURGICAL TECHNIQUE DARCO LPS Plate SURGICAL TECHNIQUE Contents Preface 3 Chapter 1 4 Chapter 2 5 5 6 7 9 Appendix 10 10 11 Design Rationale Preoperative Planning Surgical Technique Surgical Approach Joint Preparation Surgical

More information

Surgical Technique. Targeter Systems Overview

Surgical Technique. Targeter Systems Overview Surgical Technique Targeter Systems Overview PERI-LOC Locked Plating System Targeter Systems Overview Table of contents Product overview... 2 Introduction... 2 Indications... 2 Design features and benefits...

More information

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability. LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability. Technique Guide LCP Small Fragment System Table of Contents Introduction

More information

Wrist Fusion Instrument and Implant Set.

Wrist Fusion Instrument and Implant Set. Wrist Fusion Instrument and Implant Set. Surgical Technique Discontinued December 2016 DSEM/TRM/0815/0479(2) This publication is not intended for distribution in the USA. Instruments and implants approved

More information

Integra. Spider and Mini Spider Limited Wrist Fusion System SURGICAL TECHNIQUE

Integra. Spider and Mini Spider Limited Wrist Fusion System SURGICAL TECHNIQUE Integra Spider and Mini Spider Limited Wrist Fusion System SURGICAL TECHNIQUE Table of contents Description... 02 Indications... 02 Contraindications... 02 Surgical Technique... 03 Spider Introduction-Four

More information

Surgical Technique. Proximal Humerus Locking Plate

Surgical Technique. Proximal Humerus Locking Plate Surgical Technique Proximal Humerus Locking Plate PERI-LOC Upper Extremity Locked Plating System 3.5mm & 4.5mm Proximal Humerus Locking PlatesCatalog Infor Table of Contents Introduction.........................................................2

More information

DARCO. Bow 2 Plate SURGIC AL TECHNIQUE

DARCO. Bow 2 Plate SURGIC AL TECHNIQUE DARCO Bow 2 Plate SURGIC AL TECHNIQUE Contents 2 Preface 3 Chapter 1 4 Chapter 2 5 6 7 8 9 Appendix 10 10 11 Intended Use Indications/Contraindications Design Rationale Preoperative Planning Surgical Technique

More information

Zimmer Trabecular Metal Ankle Interpositional Spacer and Trabecular Metal Ankle Fusion Spacer

Zimmer Trabecular Metal Ankle Interpositional Spacer and Trabecular Metal Ankle Fusion Spacer Zimmer Trabecular Metal Ankle Interpositional Spacer and Trabecular Metal Ankle Fusion Spacer Surgical Technique 2 Zimmer Trabecular Metal Ankle Interpositional Spacer and Trabecular Metal Ankle Fusion

More information

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System.

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System. Technique Guide 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System. Table of Contents Introduction 3.5 mm LCP Low Bend Medial Distal

More information

Technique Guide. VA-Locking Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

Technique Guide. VA-Locking Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis. Technique Guide VA-Locking Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis. Table of Contents Introduction VA-Locking Intercarpal Fusion System 2 Indications

More information

Osteotomy System. The reference lines on the plate help facilitate the creation of the osteotomy, when a free hand cut is preferred.

Osteotomy System. The reference lines on the plate help facilitate the creation of the osteotomy, when a free hand cut is preferred. Osteotomy System Osteotomy System Since 1988, Acumed has been designing solutions for the demanding situations facing orthopaedic surgeons, hospitals and their patients. Our strategy has been to know the

More information

Acu-Loc Wrist Spanning Plate System. Surgical Technique

Acu-Loc Wrist Spanning Plate System. Surgical Technique Acu-Loc Wrist Spanning Plate System Surgical Technique Acumed is a global leader of innovative orthopaedic and medical solutions. We are dedicated to developing products, service methods, and approaches

More information

Open reduction; plate fixation 1 Principles

Open reduction; plate fixation 1 Principles Executive Editor: Peter Trafton Authors: Martin Jaeger, Frankie Leung, Wilson Li Proximal humerus 11-A2 Open reduction, plate fixation Search search... Shortcuts All Preparations All Approaches All Reductions

More information

LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.

LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius. Technique Guide LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius. Table of Contents Introduction LCP Proximal

More information

Contents. Chapter 1 4 Chapter Chapter Chapter Chapter 5 15

Contents. Chapter 1 4 Chapter Chapter Chapter Chapter 5 15 Contents Chapter 1 4 Chapter 2 5 5 Chapter 3 6 6 7 Chapter 4 8 8 8 8 9 10 10 11 12 13 14 14 Chapter 5 15 Introduction Intended Use Indications Device Description Implant Options and Sizing Instrumentation

More information

Surgical Technique. Distal Humerus Locking Plate

Surgical Technique. Distal Humerus Locking Plate Surgical Technique Distal Humerus Locking Plate PERI-LOC Locked Plating System Distal Humerus Locking Plate Surgical Technique Table of Contents Introduction...2 Indications...3 Plate Features...3 Patient

More information

Clover Staple. Surgical Technique

Clover Staple. Surgical Technique Clover Staple Surgical Technique Contents Product The BioPro Clover Staple is a permanent implant that removes minimal cross-sectional fusion area, allows easy radiographical monitoring and may permit

More information

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are inserted in a multiplanar and multi-directional fashion

More information

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

Surgical Technique. CONQUEST FN Femoral Neck Fracture System Surgical Technique CONQUEST FN Femoral Neck Fracture System Table of Contents Introduction... 3 Indications... 3 Product Overview... 4 Surgical Technique... 5 Patient Positioning... 5 Reduce the Fracture...

More information

Cannulated Angled Blade Plate 3.5 and 4.5, 90.

Cannulated Angled Blade Plate 3.5 and 4.5, 90. Cannulated Angled Blade Plate 3.5 and 4.5, 90. Technique Guide This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. Table of Contents Introduction

More information

AcUMEDr. FoREARM ROD SYSTEM

AcUMEDr. FoREARM ROD SYSTEM AcUMEDr FoREARM ROD SYSTEM FoREARM ROD SYSTEM Since 1988 Acumed has been designing solutions to the demanding situations facing orthopedic surgeons, hospitals and their patients. Our strategy has been

More information

Chapter 4: Forearm 4.3 Forearm shaft fractures, transverse (12-D/4)

Chapter 4: Forearm 4.3 Forearm shaft fractures, transverse (12-D/4) AO Manual of ESIN in children s fractures Chapter 4: Forearm 4.3 Forearm shaft fractures, transverse (12-D/4) Title AO Manual of ESIN in children Subtitle Elastic stable intramedullary nailing (ESIN) Author

More information

Surgical Technique Carpal Fusion

Surgical Technique Carpal Fusion Carpal Fusion Patent and Patent Pending CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a physician. INDICATIONS FOR USE The Extremity Medical Lag Screw and X-Post System

More information

Surgical Technique. Forearm Fracture Solutions

Surgical Technique. Forearm Fracture Solutions Surgical Technique Forearm Fracture Solutions Acumed is a global leader of innovative orthopaedic and medical solutions. We are dedicated to developing products, service methods, and approaches that improve

More information

2.7 mm/3.5 mm Variable Angle LCP Elbow System DJ9257-B 1

2.7 mm/3.5 mm Variable Angle LCP Elbow System DJ9257-B 1 2.7 mm/3.5 mm Variable Angle LCP Elbow System DJ9257-B 1 System overview Simply complete: A comprehensive system, consisting of five (5) distal humerus plates and three (3) types of olecranon plates Implant

More information

Low Bend Distal Tibia Plates

Low Bend Distal Tibia Plates Part of the DePuy Synthes Locking Compression Plate (LCP ) System 3.5 mm LCP Low Bend Medial Distal Tibia Plates Surgical Technique Table of Contents Introduction 3.5 mm LCP Low Bend Medial Distal Tibia

More information

Locking Radial Head Plates

Locking Radial Head Plates Locking Radial Head Plates Locking Radial Head Plates Since 1988, Acumed has been designing solutions to the demanding situations facing orthopaedic surgeons, hospitals and their patients. Our strategy

More information

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13 Contents IMPLANT FEATURES 2 1. INDICATIONS 3 2. PRE-OPERATIVE PLANNING 3 3. PATIENT POSITIONING & FRACTURE REDUCTION 3 4. INCISION 4 5. ENTRY POINT 4-6 6. PROXIMAL NAIL INSERTION 6-7 7. PROXIMAL LOCKING

More information

2.4 mm LCP Radial Head Plates. Part of the Synthes LCP Distal Radius Plate System.

2.4 mm LCP Radial Head Plates. Part of the Synthes LCP Distal Radius Plate System. 2.4 mm LCP Radial Head Plates. Part of the Synthes LCP Distal Radius Plate System. Technique Guide Instruments and Implants approved by the AO Foundation Table of Contents Introduction 2.4 mm LCP Radial

More information

LCP Distal Tibia Plate

LCP Distal Tibia Plate Surgical Technique LCP Locking Compression Plate Original Instruments and Implants of the Association for the Study of Internal Fixation AO/ASIF Table of contents Indications 3 Implants/Instruments 5 Surgical

More information

DISTAL ELBOW SET. proximal ulna plate SURGICAL TECHNIQUE GUIDE

DISTAL ELBOW SET. proximal ulna plate SURGICAL TECHNIQUE GUIDE SURGICAL TECHNIQUE GUIDE DISTAL ELBOW SET proximal ulna plate As described by: Jorge L. Orbay, M.D. Miami Hand & Upper Extremity Institute Miami, Florida DISTAL ELBOW SET proximal ulna plate Indications

More information

Distal Ulnar Locking Plate

Distal Ulnar Locking Plate INDEX Indications Patient Position Surgical Technique - Step 1 Approach - Step 2 Plate Contouring - Step 3 Fracture Reduction - Step 4 Distal Plate Fixation - Step 5 Confirm Proper Reconstruction - Step

More information

LCP Low Bend Medial Distal Tibia Plates 3.5 mm. Anatomic plates with low profile head for intra- and extraarticular fractures.

LCP Low Bend Medial Distal Tibia Plates 3.5 mm. Anatomic plates with low profile head for intra- and extraarticular fractures. LCP Low Bend Medial Distal Tibia Plates 3.5 mm. Anatomic plates with low profile head for intra- and extraarticular fractures. Surgical Technique This publication is not intended for distribution in the

More information

Technique Guide. 2.7 mm/3.5 mm LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

Technique Guide. 2.7 mm/3.5 mm LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system. Technique Guide 2.7 mm/3.5 mm LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system. Table of Contents Introduction 2.7 mm/3.5 mm LCP Distal Fibula Plates 2 AO Principles

More information

Surgical Technique. Olecranon Locking Plate

Surgical Technique. Olecranon Locking Plate Surgical Technique Olecranon Locking Plate PERI-LOC Locked Plating System Olecranon Locking Plate Surgical Techniquealog Infor Table of Contents Introduction...2 Indications...3 Plate Features...3 Patient

More information

Acu-Loc Wrist Plating System. Surgical Technique

Acu-Loc Wrist Plating System. Surgical Technique Acu-Loc Wrist Plating System Surgical Technique Acumed is a global leader of innovative orthopaedic and medical solutions. We are dedicated to developing products, service methods, and approaches that

More information

SMV Scientific Bone Plate and Screw System Surgical Technique

SMV Scientific Bone Plate and Screw System Surgical Technique SMV Scientific Bone Plate and Screw System Surgical Technique Description: The SMV Scientific Bone Plate and Screw System consists of non-locking plates and bone screw fasteners in a variety of lengths,

More information

Surgical Technique. Elbow Plating System

Surgical Technique. Elbow Plating System Surgical Technique Elbow Plating System Acumed is a global leader of innovative orthopaedic and medical solutions. We are dedicated to developing products, service methods, and approaches that improve

More information

Technique Guide. Adjustable Distal Radius Fixator. Part of the Synthes External Fixation Systems.

Technique Guide. Adjustable Distal Radius Fixator. Part of the Synthes External Fixation Systems. Technique Guide Adjustable Distal Radius Fixator. Part of the Synthes External Fixation Systems. Table of Contents Introduction Adjustable Distal Radius Fixator 2 Indications 3 Surgical Technique Configure

More information

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system. LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system. Technique Guide This publication is not intended for distribution in the USA. Instruments

More information

Zimmer MIS Periarticular 3.5mm Proximal Tibial Locking Plate

Zimmer MIS Periarticular 3.5mm Proximal Tibial Locking Plate Zimmer MIS Periarticular 3.5mm Proximal Tibial Locking Plate Surgical Technique The Science of the Landscape Zimmer MIS Periarticular 3.5mm Proximal Tibial Locking Plate Surgical Technique 1 Zimmer MIS

More information

Surgical Technique. Cannulated Angled Blade Plate 3.5 and 4.5, 90

Surgical Technique. Cannulated Angled Blade Plate 3.5 and 4.5, 90 Surgical Technique Cannulated Angled Blade Plate 3.5 and 4.5, 90 Cannulated Angled Blade Plate 3.5 and 4.5, 90 Table of contents Indications/Contraindications 2 Implants 3 Surgical technique 5 Implant

More information

Locking Ankle Plating System. Surgical Technique

Locking Ankle Plating System. Surgical Technique Locking Ankle Plating System Surgical Technique Acumed is a global leader of innovative orthopaedic and medical solutions. We are dedicated to developing products, service methods, and approaches that

More information

LCP Wrist Fusion Set. Anatomic plates for total wrist fusion.

LCP Wrist Fusion Set. Anatomic plates for total wrist fusion. LCP Wrist Fusion Set. Anatomic plates for total wrist fusion. Technique Guide This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. Table

More information

AxSOS. Locking Plate System. Operative Technique. Small Fragment Basic Fragment

AxSOS. Locking Plate System. Operative Technique. Small Fragment Basic Fragment AxSOS Locking Plate System Operative Technique Small Fragment Basic Fragment Stryker Plating Contents Page 1. Introduction 4 2. Features & Benefits 5 4 and 5 Compression Plates 5 Reconstruction and 1/3

More information

3.5 mm LCP Extra-articular Distal Humerus Plate

3.5 mm LCP Extra-articular Distal Humerus Plate Part of the DePuy Synthes Locking Compression Plate (LCP ) System 3.5 mm LCP Extra-articular Distal Humerus Plate Surgical Technique Table of Contents Introduction 3.5 mm LCP Extra-articular Distal Humerus

More information

AxSOS Locking Plate System

AxSOS Locking Plate System AxSOS Locking Plate System Operative Technique Small Fragment Basic Fragment 1 2 Contents Page 1. Introduction 4 2. Features & Benefits 5 4 and 5mm Compression Plates 5 Reconstruction and 1/3 Tubular Locking

More information

Surgical Technique. Anterolateral and Medial Distal Tibia Locking Plates

Surgical Technique. Anterolateral and Medial Distal Tibia Locking Plates Surgical Technique Anterolateral and Medial Distal Tibia Locking Plates PERI-LOC Periarticular Locked Plating System Anterolateral and Medial Distal Tibia Locking Plates Surgical Technique Contents Product

More information

NCB Distal Femur System. Surgical Technique

NCB Distal Femur System. Surgical Technique NCB Distal Femur System Surgical Technique NCB Distal Femur System Surgical Technique 3 Surgical Technique NCB Distal Femur System Table of Contents Introduction 4 Indications 8 Preoperative Planning

More information

Distal Radius and Distal Ulna Plates System Self-Tapping Spherical Locking Screw Self-Tapping Conical Locking Screw Cortex Screw

Distal Radius and Distal Ulna Plates System Self-Tapping Spherical Locking Screw Self-Tapping Conical Locking Screw Cortex Screw DISTAL RADIUS AND ULNA LOCKING PLATE SYSTEM Surgical Technique Distal Radius and Distal Ulna Plates System Self-Tapping Spherical Locking Screw Self-Tapping Conical Locking Screw Cortex Screw Approved

More information

The Flower Medial Column Fusion Plate

The Flower Medial Column Fusion Plate The Flower Medial Column Fusion Plate PROCEDURE GUIDE www.flowerortho.com The Flower Foot & Ankle Application NC FUSION PLATE 2-HOLE COMPRESSION PLATE TMT FUSION PLATE LAPIDUS FUSION PLATE COMPRESSION

More information

PROXIMAL TIBIAL PLATE

PROXIMAL TIBIAL PLATE SURGICAL NÁSTROJE TECHNIQUE PRO ARTROSKOPII PROXIMAL INSTRUMENTS TIBIAL FOR PLATE ARTHROSCOPY Proximal Tibial Plate Description of medical device The Proximal Tibial Plate is used in epyphyseal and metaphyseal

More information

3.5 MM VA-LCP PROXIMAL TIBIA PLATE SYSTEM

3.5 MM VA-LCP PROXIMAL TIBIA PLATE SYSTEM 3.5 MM VA-LCP PROXIMAL TIBIA PLATE SYSTEM Part of the DePuy Synthes Variable Angle Periarticular Plating System SURGICAL TECHNIQUE TABLE OF CONTENTS INTRODUCTION 3.5 mm VA-LCP Proximal Tibial Plate 2 AO

More information

MINI TIBIAL PLATEAU LEVELING OSTEOTOMY (TPLO) SYSTEM

MINI TIBIAL PLATEAU LEVELING OSTEOTOMY (TPLO) SYSTEM MINI TIBIAL PLATEAU LEVELING OSTEOTOMY (TPLO) SYSTEM For stabilizing osteotomies of the canine and feline proximal tibia SURGICAL TECHNIQUE TABLE OF CONTENTS INTRODUCTION Mini Tibial Plateau Leveling

More information

Surgical Technique. Clavicle Locking Plate

Surgical Technique. Clavicle Locking Plate Surgical Technique Clavicle Locking Plate PERI-LOC Locked Plating System Clavicle Locking Plate Surgical Technique Table of Contents Introduction...2 Indications...3 Plate Features...3 Patient Positioning...4

More information

Technique Guide. 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system.

Technique Guide. 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system. Technique Guide 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system. Table of Contents Introduction 3.5 mm LCP Proximal Humerus Plate 2 AO Principles

More information

2.4 mm Variable Angle LCP Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

2.4 mm Variable Angle LCP Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis. 2.4 mm Variable Angle LCP Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis. Technique Guide Instruments and implants approved by the AO Foundation Table

More information

Technique Guide. 3.5 mm LCP Proximal Tibia Plate. Part of the Synthes Small Fragment LCP System.

Technique Guide. 3.5 mm LCP Proximal Tibia Plate. Part of the Synthes Small Fragment LCP System. Technique Guide 3.5 mm LCP Proximal Tibia Plate. Part of the Synthes Small Fragment LCP System. Table of Contents AO ASIF Principles of Internal Fixation 4 Indications/Contraindications 5 Surgical Technique

More information

SURGICAL TECHNIQUE GUIDE

SURGICAL TECHNIQUE GUIDE DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a potentially hazardous situation which, if not avoided, could result

More information

Merete PlantarMAX Lapidus Plate Surgical Technique. Description of Plate

Merete PlantarMAX Lapidus Plate Surgical Technique. Description of Plate Merete PlantarMAX Lapidus Plate Surgical Technique Description of Plate Merete Medical has designed the PlantarMax; a special Plantar/Medial Locking Lapidus plate which places the plate in the most biomechanically

More information

WINSTA-R. Distal Radius System

WINSTA-R. Distal Radius System Distal Radius System Table of Contents Introduction WINSTA-R System 2 Indication 2 Surgical Technique Palmar Access for Radius Plate 3 Dorsal Access for Radius Plate 3 Positioning of the Radius Plate

More information

CHARLOTTE. 7.0 Multi-Use Compression Screw System SURGICAL TECHNIQUE

CHARLOTTE. 7.0 Multi-Use Compression Screw System SURGICAL TECHNIQUE CHARLOTTE 7.0 Multi-Use Compression Screw System SURGICAL TECHNIQUE Contents Chapter 1 1 Chapter 2 2 2 3 4 Appendix A 5 6 Appendix B 7 8 Preoperative Planning Surgical Technique Subtalar Arthrodesis Guide

More information

VA-LCP Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

VA-LCP Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle. Technique Guide VA-LCP Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle. Table of Contents Introduction VA-LCP Anterior

More information

System. Humeral Nail. Surgical Technique

System. Humeral Nail. Surgical Technique System Humeral Nail Surgical Technique Contents IMPLANT FEATURES 2 1. INDICATIONS 3 2. PRE-OPERATIVE PLANNING 3 3. PATIENT POSITIONING & FRACTURE REDUCTION 3 4. INCISION 4 5. ENTRY POINT 4-6 6. PROXIMAL

More information

Wrist Fixation System

Wrist Fixation System Wrist Fixation System Anatomy / Fracture Implant EXTRA & SIMPLE ARTICULAR Volar Radius Volar Fixed Angle Plate Volar Bearing Plate Radial Peg Plate Volar Hook Plate Volar Buttress Pin Volar Shear Plate

More information

CANNULINK. Intraossous Fixation System SURGICAL TECHNIQUE

CANNULINK. Intraossous Fixation System SURGICAL TECHNIQUE CANNULINK Intraossous Fixation System SURGICAL TECHNIQUE Contents Chapter 1 4 Introduction The CANNULINK Advantage Indications for Use Preoperative Planning Chapter 2 5 Surgical Technique CANNULINK Standard

More information

3.5 mm LCP Olecranon Plates

3.5 mm LCP Olecranon Plates Part of the DePuy Synthes Locking Compression Plate (LCP ) System 3.5 mm LCP Olecranon Plates Surgical Technique Table of Contents Introduction 3.5 mm LCP Olecranon Plates 2 AO Principles 3 Indications

More information

Olecranon Locking Plate II

Olecranon Locking Plate II INDEX Indications Patient Position Fracture Reduction and Fixation Surgical Technique Step 1 Surgical Approach Step 2 Implantation Step 3 Proximal Locking Screw Insertion Step 4 Distal Screw Insertion

More information

Technique Guide. LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

Technique Guide. LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system. Technique Guide LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system. Table of Contents Introduction LCP Distal Fibula Plates 2 AO Principles 4 Indications 5 Surgical Technique

More information

PediLoc 3.5mm and 4.5mm Contour Femur Plate Surgical Technique

PediLoc 3.5mm and 4.5mm Contour Femur Plate Surgical Technique PediLoc 3.5mm and 4.5mm Contour Femur Plate Surgical Technique Surgical Technique Contour Femur Plate The technique description herein is made available to the healthcare professional to illustrate the

More information

Axi+LineTM Proximal Bunion CorrectionSystem. Surgical Technique

Axi+LineTM Proximal Bunion CorrectionSystem. Surgical Technique Axi+LineTM Proximal Bunion CorrectionSystem Surgical Technique A i Line Proximal Bunion Correction System TM Desired angle correction is built into the plate, providing a self-reducing, 5-hole construct

More information

CHARLOTTE. 7.0 Multi-Use Compression Screw System SURGICAL TECHNIQUE

CHARLOTTE. 7.0 Multi-Use Compression Screw System SURGICAL TECHNIQUE CHARLOTTE 7.0 Multi-Use Compression Screw System SURGICAL TECHNIQUE Contents Chapter 1 1 Chapter 2 2 Chapter 3 3-9 Chapter 4 10-12 Appendix A 13-14 Design Rationale Screw Behavior Surgical Technique Procedure

More information

Zimmer Small Fragment Universal Locking System

Zimmer Small Fragment Universal Locking System Zimmer Small Fragment Universal Locking System Surgical Technique Flexibility and compatibility in one system Zimmer Small Fragment Universal Locking System Zimmer Small Fragment Universal Locking System

More information

QUICK REFERENCE GUIDE. The Pennig Dynamic Wrist Fixator. Part A: Trans-articular application

QUICK REFERENCE GUIDE. The Pennig Dynamic Wrist Fixator. Part A: Trans-articular application 10 The Pennig Dynamic Wrist Fixator Part A: Trans-articular application B1 B2 B3 III IV TRANS-ARTICULAR APPLICATION The fractures that can be treated with this technique include AO type B and C fractures,

More information

Surgical Technique. 3.5mm and 4.5mm Lateral Proximal Tibia Locking Plates

Surgical Technique. 3.5mm and 4.5mm Lateral Proximal Tibia Locking Plates Surgical Technique 3.5mm and 4.5mm Lateral Proximal Tibia Locking Plates PERI-LOC Periarticular Locked Plating System 3.5mm and 4.5mm Lateral Proximal Tibia Locking Plate Surgical Technique Contents Product

More information

Biomet Large Cannulated Screw System

Biomet Large Cannulated Screw System Biomet Large Cannulated Screw System s u r g i c a l t e c h n i q u e A Complete System for Simplified Fracture Fixation 6.5mm & 7.3mm The Titanium, Self-drilling, Self-tapping Large Cannulated Screw

More information

Conventus CAGE PH Surgical Techniques

Conventus CAGE PH Surgical Techniques Conventus CAGE PH Surgical Techniques Conventus Orthopaedics The Conventus CAGE PH (PH Cage) is a permanent implant comprised of an expandable scaffold, made from nitinol and titanium, which is deployed

More information

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. 2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. Surgical Technique This publication is not intended

More information