PROFIBUS DP cables. 1 Order data. PROFIBUS DP cables. Table 1: X67CA0Bxx PROFIBUS DP cables - Order data. Data sheet V

Size: px
Start display at page:

Download "PROFIBUS DP cables. 1 Order data. PROFIBUS DP cables. Table 1: X67CA0Bxx PROFIBUS DP cables - Order data. Data sheet V"

Transcription

1 PROFIBUS DP cables 1 Order data, model number Length PROFIBUS DP connection cable PROFIBUS DP attachment cable PROFIBUS DP open-ended cable 2.0 m X67CA0B X67CA0B m X67CA0B X67CA0B X67CA0B X67CA0B X67CA0B X67CA0B m X67CA0B X67CA0B m X67CA0B X67CA0B X67CA0B X67CA0B X67CA0B X67CA0B m X67CA0B X67CA0B X67CA0B X67CA0B2.000 Page Table 1: X67CA0Bxx PROFIBUS DP cables - Order data Data sheet V

2 2 Technical data 2.1 X67CA0B02. Product ID X67CA0B X67CA0B X67CA0B X67CA0B Flame resistant in accordance with VDE 0482 part / IEC PROFIBUS DP connection cable Connection cables B&R X67CA0Bxx. Fine stranded wires 0.34 (22 AWG) Max. 12 V AC/DC Conductor resistance 14 Ω/km at 20 C resistance 1 Ω/km at 20 C Insulation resistance GΩ/km at 20 C EN 6029 protection Fixed installation -2 to 70 C Flexible installation -2 to 70 C Length 2 m m 10 m 1 m 6 mm when flexed > million Max. 4.0 m/s with. m horiz. traverse path distance Table 2: X67CA0B , X67CA0B02.000, X67CA0B , X67CA0B Technical data 2 Data sheet V 2.10

3 2.2 X67CA0B12. Product ID X67CA0B X67CA0B X67CA0B X67CA0B Flame resistant in accordance with VDE 0482 part / IEC PROFIBUS DP connection cable, angled Connection cables B&R X67CA0Bxx. Fine stranded wires 0.34 (22 AWG) Max. 12 V AC/DC Conductor resistance 14 Ω/km at 20 C resistance 1 Ω/km at 20 C Insulation resistance GΩ/km at 20 C EN 6029 protection Fixed installation -2 to 70 C Flexible installation -2 to 70 C Length 2 m m 10 m 1 m 6 mm when flexed > million Max. 4.0 m/s with. m horiz. traverse path distance Table 3: X67CA0B , X67CA0B12.000, X67CA0B , X67CA0B Technical data Data sheet V

4 2.3 X67CA0B22. Product ID X67CA0B X67CA0B X67CA0B Flame resistant in accordance with VDE 0482 part / IEC PROFIBUS DP attachment cable Attachment cable B&R X67CA0Bxx. Fine stranded wires 0.34 (22 AWG) Max. 12 V AC/DC Conductor resistance 14 Ω/km at 20 C resistance 1 Ω/km at 20 C Insulation resistance GΩ/km at 20 C EN 6029 protection Fixed installation -2 to 70 C Flexible installation -2 to 70 C Length m 1 m 0 m 6 mm when flexed > million Max. 4.0 m/s with. m horiz. traverse path distance Table 4: X67CA0B22.000, X67CA0B22.010, X67CA0B Technical data 4 Data sheet V 2.10

5 2.4 X67CA0B32. Product ID X67CA0B X67CA0B X67CA0B Flame resistant in accordance with VDE 0482 part / IEC PROFIBUS DP attachment cable, angled Attachment cable B&R X67CA0Bxx. Fine stranded wires 0.34 (22 AWG) Max. 12 V AC/DC Conductor resistance 14 Ω/km at 20 C resistance 1 Ω/km at 20 C Insulation resistance GΩ/km at 20 C EN 6029 protection Fixed installation -2 to 70 C Flexible installation -2 to 70 C Length m 1 m 0 m 6 mm when flexed > million Max. 4.0 m/s with. m horiz. traverse path distance Table : X67CA0B32.000, X67CA0B32.010, X67CA0B Technical data Data sheet V 2.10

6 2. X67CA0B42. Product ID X67CA0B X67CA0B X67CA0B Flame resistant in accordance with VDE 0482 part / IEC PROFIBUS DP open-ended cable Open-ended cable B&R X67CA0Bxx. Fine stranded wires 0.34 (22 AWG) Max. 12 V AC/DC Conductor resistance 14 Ω/km at 20 C resistance 1 Ω/km at 20 C Insulation resistance GΩ/km at 20 C EN 6029 protection Fixed installation -2 to 70 C Flexible installation -2 to 70 C Length m 1 m 0 m 6 mm when flexed > million Max. 4.0 m/s with. m horiz. traverse path distance Table 6: X67CA0B42.000, X67CA0B42.010, X67CA0B Technical data 6 Data sheet V 2.10

7 2.6 X67CA0B2. Product ID X67CA0B2.000 X67CA0B2.010 X67CA0B2.000 Flame resistant in accordance with VDE 0482 part / IEC PROFIBUS DP open-ended cable, angled Open-ended cable B&R X67CA0Bxx. Fine stranded wires 0.34 (22 AWG) Max. 12 V AC/DC Conductor resistance 14 Ω/km at 20 C resistance 1 Ω/km at 20 C Insulation resistance GΩ/km at 20 C EN 6029 protection Fixed installation -2 to 70 C Flexible installation -2 to 70 C Length m 1 m 0 m 6 mm when flexed > million Max. 4.0 m/s with. m horiz. traverse path distance Table 7: X67CA0B2.000, X67CA0B2.010, X67CA0B Technical data Data sheet V

8 3 X67CA0B02. 1 M Male connector Pin Name Wire color Female connector 1 + V 1) SHLD Table 8: X67CA0B02 PROFIBUS DP connection cables - and pinout 2) ing on M12 knurled-head screw 360 as well as pin. X67CA0B X67CA0B X67CA0B X67CA0B X67CA0B12. Table 9: X67CA0B02 PROFIBUS DP connection cables M Male connector Pin Name Wire color Female connector 1 + V 1) SHLD Table 10: X67CA0B12 PROFIBUS DP connection cables - and pinout 2) ing on M12 knurled-head screw 360 as well as pin. X67CA0B X67CA0B X67CA0B X67CA0B Table 11: X67CA0B12 PROFIBUS DP connection cables - 8 Data sheet V 2.10

9 X67CA0B22. 1 Braided shield, twisted wires and approx. mm tinned 39 0 Female connector Pin Name Wire color Open V 1) SHLD Table 12: X67CA0B22 PROFIBUS DP attachment cables - and pinout 2) ing on M12 knurled-head screw 360 as well as pin. For custom Wiring X67CA0B X67CA0B X67CA0B X67CA0B32. Table 13: X67CA0B22 PROFIBUS DP attachment cables - Braided shield, twisted wires and approx. mm tinned Female connector Pin Name Wire color Open V 1) SHLD Table 14: X67CA0B32 PROFIBUS DP attachment cables - and pinout 2) ing on M12 knurled-head screw 360 as well as pin. For custom Wiring X67CA0B X67CA0B X67CA0B Table 1: X67CA0B32 PROFIBUS DP attachment cables - Data sheet V

10 7 X67CA0B42. 1 M12 Braided shield, twisted wires and approx. mm tinned 42 0 Male connector Pin Name Open V 1) SHLD Table 16: X67CA0B42 PROFIBUS DP DP open-ended cables - and pinout 2) ing on M12 knurled-head screw 360 as well as pin. For custom Wiring X67CA0B X67CA0B X67CA0B X67CA0B2. Table 17: X67CA0B42 PROFIBUS DP open-ended cables - Braided shield, twisted wires and approx. mm tinned 3 0 M Male connector Pin Name Open V 1) SHLD Table 18: X67CA0B2 PROFIBUS DP DP open-ended cables - and pinout 2) ing on M12 knurled-head screw 360 as well as pin. For custom Wiring X67CA0B X67CA0B X67CA0B Table 19: X67CA0B2 PROFIBUS DP open-ended cables - 10 Data sheet V 2.10

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications Data Sheet 10/63-6.47-EN Rev. C PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

More information

Datasheet BR Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors

Datasheet BR Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors Datasheet BR Series /CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors NEW Compared to traditional fuse installation, the /CSA C22.2 No.5-02, UL1077/CSA

More information

BU 0,6/1(1,2)kV P17 Power cable, Unarmoured MGT/EPR/EVA. Standards applied. No inner covering. (Additional tapes may be applied) Armour/screen

BU 0,6/1(1,2)kV P17 Power cable, Unarmoured MGT/EPR/EVA. Standards applied. No inner covering. (Additional tapes may be applied) Armour/screen Page 1 of 5 Fire resistant, flame retardant halogen-free power cable. Mud resistant BU 0,6/1(1,2)kV MGT/EPR/EVA NEK TS 606 CodeP17 Operating temperature : 90 C Operating Voltage : 0,6/1(1,2)kV Application

More information

Fieldbus Systems. Fieldbus System: Devicenet

Fieldbus Systems. Fieldbus System: Devicenet Fieldbus Systems Fieldbus System: Devicenet For a simple choice of outstanding network components, Balluff offers the entire spectrum of high-performance network technology. For applications in the USA,

More information

SPLICING CUSTOMER PREMISE WIRE AND CABLE GENERAL INSTRUCTIONS FOR SPLICING PREMISE WIRE...* *...

SPLICING CUSTOMER PREMISE WIRE AND CABLE GENERAL INSTRUCTIONS FOR SPLICING PREMISE WIRE...* *... SOUTHWESTERN BELL TELEPHONE PRACTICE SWBT Standard SECTION SW 461-200-901 Issue A, June 1989 SPLICING CUSTOMER PREMISE AND CABLE CONTENTS PAGE 1. GENERAL...*..*...***.....0.0.00 0......0.....0......00..

More information

Al and AlCu terminals and connectors mm²

Al and AlCu terminals and connectors mm² Al and AlCu terminals and connectors 16-1200 ² General information 2 Al terminals 16-1200 ² 3 Through connectors with partition 16-1200 ² 4 Through connectors without partition 0-240 ² Through connectors

More information

Guidelines for Identifying Externalized Conductors on Radiographic Images

Guidelines for Identifying Externalized Conductors on Radiographic Images Guidelines for Identifying Externalized Conductors on Radiographic Images These guidelines for determining the presence of externalized conductors were used by independent physician adjudicators in the

More information

Multi-Conductor, Unshielded, Riser NEC Type CMR and/or CL3R

Multi-Conductor, Unshielded, Riser NEC Type CMR and/or CL3R Multi-Conductor, Unshielded, Riser NEC Type CMR and/or CL3R W221P-1052 2 22 7/30 0.008 0.20 0.015 0.38 0.122 9 lbs. W223C-1193 3 22 7/30 0.008 0.20 0.015 0.38 0.129 11 lbs. W224C-1108 4 22 7/30 0.008 0.20

More information

Easy assembly with standard tools. Fully insulated for direct mounting to steel panels

Easy assembly with standard tools. Fully insulated for direct mounting to steel panels Cam-Lok J Series Connectors or NEMA 4 Cam-Lok J Series Connectors are specifically designed to meet the needs of demanding portable applications. J Series Plugs and Receptacles are the proven industry

More information

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC Defining Cutting Edge Quality Laser Cutting Head BIMO-FSC BIMO-FSC Laser Cutting Head BIMO-FSC for Flexible Flat Sheet Cutting The use of fibre lasers for cutting applications is growing steadily. The

More information

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC Defining Cutting Edge Quality Laser Cutting Head BIMO-FSC BIMO-FSC Modules 40 Laser light cable receiver Cover slide in front of collimation 9 46,5 0,2 86,5 64,4 2,5 131,2 Collimation module with manual

More information

Installation Instructions

Installation Instructions Installation Instructions 1View Manager 96 Enhanced OUCH RACKER Contents About his Document...1 Planning the OUCH RACKER Network...1 Backbone Network Guidelines...2 Star Network Guidelines...2 Installing

More information

Fortimo LED Square. Datasheet

Fortimo LED Square. Datasheet LED Square 380 mm 5000 lm HV1 Datasheet Fortimo LED Square Fortimo LED Square systems consist of white light LED modules with square outer dimensions delivering high energy efficiency and high quality

More information

High current plug-in connector

High current plug-in connector 2017.12 High current plug-in connector with a wrong insertion prevention mechanism Plug-in Connector (A Wrong Insertion Prevention Mechanism) Features of the high current plug-in connector with a wrong

More information

COLD LEAD OPTIONS FOR XMI MINERAL INSULATED (MI) HEATING CABLES

COLD LEAD OPTIONS FOR XMI MINERAL INSULATED (MI) HEATING CABLES FOR XMI MINERAL INSULATED (MI) HEATING CABLES PRODUCT OVERVIEW XMI with standard MI cold lead and Type X connector MI cable heated section PRODUCT OVERVIEW XMI with PyroFLX cold lead and Type K connector

More information

All dimensions are in mm. Plug: Coding Pin: HOODS TOP ENTRY HOODS. NPT Part # NP NP 10.

All dimensions are in mm. Plug: Coding Pin: HOODS TOP ENTRY HOODS. NPT Part # NP NP 10. HA 3&4 Plugs & Receptacles HA 3&4 Housings: Single Lever on Base SCREW TERMINATED INSERTS HA 3 HA 4 All dimensions are in mm. HA 3 HA 4 Plug: 10.40 10.4310 Receptacle: 10.40 10.43 Coding Pin: 10.4513 TOP

More information

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC Defining Cutting Edge Quality Laser Cutting Head BIMO-FSC Optical System Perfectly Focused on Highest Productivity The BIMO-FSC s optical system is set-up modularly. This provides different options for

More information

Fortimo LED Strip Gen3

Fortimo LED Strip Gen3 Strip Gen3 2 ft 2200 lm 1R HV3 Datasheet Fortimo LED Strip Gen3 Fortimo LED Strip systems are ideal for use in designer or miniaturized, slim linear luminaires for architectural applications, which were

More information

S202M-K2UC. Miniature Circuit Breaker - S200MUC - 2P - K - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

S202M-K2UC. Miniature Circuit Breaker - S200MUC - 2P - K - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions. ABB Miniature Circuit Breaker - S00MUC - P - K - ampere General Information Extended Product Type Product ID S0M-KUC CDS7061R077 EAN 4013614433146 Catalog Description Long Description Miniature Circuit

More information

Nexans Olex New Zealand

Nexans Olex New Zealand Nexans Olex New Zealand Price list Effective 1 st September 2012 The Olex Range Low Voltage Power and Control Cables Building Wires Flats PVC/PVC SDIs XLPE/PVC Single Cores PVC/PVC Circulars XLPE/PVC Multicores

More information

MS MS Manual Motor Starter. Generell informasjon. Ordering. Popular Downloads. Dimensions. Technical MS Extended Product Type

MS MS Manual Motor Starter. Generell informasjon. Ordering. Popular Downloads. Dimensions. Technical MS Extended Product Type ABB Manual Motor Starter Generell informasjon Extended Product Type Product ID 1SAM451000R1015 EAN 401614486098 Catalog Description Long Description Manual Motor Starter MS165 is a compact and powerful

More information

NASA Space-Qualified Thermistors

NASA Space-Qualified Thermistors NASA Space-Qualified Thermistors YSI 44900 Series Goddard Space Flight Center GSFC S-3-P-8 NASA has qualified YSI epoxy-encapsulated thermistors for use in extended space flight. The Goddard Space Flight

More information

BS 5467 PVC. stranded / Class 2 0,387 0,268 0,193 0,153 0,124 0,099 0,075. Insulation resistance Min. MΩxkm Individual conductor 1000 Test voltage

BS 5467 PVC. stranded / Class 2 0,387 0,268 0,193 0,153 0,124 0,099 0,075. Insulation resistance Min. MΩxkm Individual conductor 1000 Test voltage BS 5467 PVC Cable Instrument Cable Standard BS 5467 Voltage 06/1KV Description Copper, Multi Core, XLPE-, Armour, PVC Sheath Cable type BS 5467 Electrical data a 20ºC Conductor size Nom mm² 1,5 2,5 4 6

More information

Miniature Circuit Breaker - S200-1P - B - 2 ampere. acc. to IEC / 400 V AC acc. to IEC V AC

Miniature Circuit Breaker - S200-1P - B - 2 ampere. acc. to IEC / 400 V AC acc. to IEC V AC ABB Miniature Circuit Breaker - S200-1P - B - 2 ampere General Information Extended Product Type S201-B2 Product ID 2CDS251001R0025 EAN 4016779612944 Catalog Description Miniature Circuit Breaker - S200-1P

More information

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0 The sensor series SONOFLOW CO.55/xxx V2.0 designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a few milliseconds. For applications on

More information

MEDICAL CORPORATION Asbury Rd., P.O. Box 758, Farmingdale, NJ USA Fax

MEDICAL CORPORATION Asbury Rd., P.O. Box 758, Farmingdale, NJ USA Fax MEDICAL CORPORATION 5206 Asbury Rd., P.O. Box 758, Farmingdale, NJ 07727 USA 732-938-2266 800-323-4035 Fax 732-938-2399 MYO/WIRE Temporary Cardiac Pacing Wire System MYO/WIRE temporary cardiac pacing wires.

More information

Assembly Instruction for Fiber Optic Series FOH Fischer Connectors

Assembly Instruction for Fiber Optic Series FOH Fischer Connectors Assembly Instruction for Fiber Optic Series FOH Fischer Connectors Table des matières 1 Introduction... 3 2 Document history... 3 3 Definitions and Acronyms... 3 4 FOH Plugs & Receptacles with Potting

More information

SWITCHGEAR PBD. fuse bases

SWITCHGEAR PBD. fuse bases SWITCHGEAR PBD fuse bases designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links ENERGY SAFELY SWITCHED SWITCHGEAR

More information

SWITCHGEAR PBD. fuse bases

SWITCHGEAR PBD. fuse bases SWITCHGEAR PBD fuse bases designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links ENERGY SAFELY SWITCHED SWITCHGEAR

More information

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type ABB Manual Motor Starter General Information Extended Product Type Product ID 1SAM250000R1008 EAN 4013614320316 Catalog Description Long Description Manual Motor Starter The manual motor starter (also

More information

General Information. Ordering. Popular Downloads. Dimensions. Products Low Voltage Products and Systems Circuit Breakers Manual Motor Starters

General Information. Ordering. Popular Downloads. Dimensions. Products Low Voltage Products and Systems Circuit Breakers Manual Motor Starters MS132-1.6-HKF1-11 Products Low Voltage Products and Systems Circuit Breakers Manual Motor Starters Products Low Voltage Products and Systems Control Products Manual Motor Starters Manual Motor Starters

More information

Installation Instructions

Installation Instructions Instructions Midrange Self-Contained Unit Accessory: Indeeco Electric Heat Used with Models SCWJ, SCRJ 3, 5, 7.5, 10, 12, and 15 Tons AO and later design sequence SAFETY WARNING Only qualified personnel

More information

S201-Z2. Miniature Circuit Breaker - S200-1P - Z - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

S201-Z2. Miniature Circuit Breaker - S200-1P - Z - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions. ABB Miniature Circuit Breaker - S200-1P - Z - 2 ampere General Information Extended Product Type Product ID S201-Z2 2CDS251001R0278 EAN 40167795054 Catalog Description Long Description Miniature Circuit

More information

Bio Mechanical Hoof Tester Operator s Manual

Bio Mechanical Hoof Tester Operator s Manual Bio Mechanical Hoof Tester Operator s Manual Introduction: To inform the user, this manual will begin with a set of reference figures outlining the components of the Bio Mechanical Hoof Tester. The manual

More information

Instrumentation Cables

Instrumentation Cables Instrumentation Cables Introduction....2 300 V PVC Insulated, PVC Jacketed PLTC/ITC Rated Applications and Description....3 Overall Shielded Pairs....4 Overall Shielded Triads...5 Individual and Overall

More information

A-dec Dental Light on an A-dec 200 Dental Chair I NSTALLATION GUIDE

A-dec Dental Light on an A-dec 200 Dental Chair I NSTALLATION GUIDE A-dec 371-00 Dental Light on an A-dec 00 Dental Chair I NSTALLATION GUIDE Install the Dental Light 1 3 4 1. Insert and fully seat the bearing in the support center post.. Place the trim cover on top of

More information

INSTRUMENTATION. 300 Volt and 600 Volt Cables LEAD FREE O V E R Y E A R S O F E X P E R I E N C E. w w w. n e x a n s e n e r g y.

INSTRUMENTATION. 300 Volt and 600 Volt Cables LEAD FREE O V E R Y E A R S O F E X P E R I E N C E. w w w. n e x a n s e n e r g y. INSTRUMENTATION 300 Volt and 600 Volt Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Instrumentation Cables Introduction....2 300 V

More information

Based on the selected Content Inventory Threshold:

Based on the selected Content Inventory Threshold: PUFR6X04**-UG TX6A 10 Gig Category 6A U/FTP CMR by Panduit CLASSIFICATION: 27 10 00 PRODUCT DESCRIPTION: Category 6A, riser (CMR), 4-pair, U/FTP shielded copper cable. Copper conductors are 23 AWG with

More information

Technical support: +49 (0)7223 /

Technical support: +49 (0)7223 / ISO 9001 certified Technical support: +49 (0)7223 / 9493-0 Technical description ADDIVARIOUS PX 901 Screw terminal board 8 th edition 08/2000 Copyright All rights reserved. This manual is intended for

More information

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type ABB MS132-6.3 Manual Motor Starter General Information Extended Product Type Product ID MS132-6.3 1SAM350000R1009 EAN 4013614400094 Catalog Description Long Description MS132-6.3 Manual Motor Starter The

More information

PROFIBUS Products Overview P PROFIBUS Converter/Repeater P PROFIBUS Gateway P6-3-1

PROFIBUS Products Overview P PROFIBUS Converter/Repeater P PROFIBUS Gateway P6-3-1 .1. Overview P-1-1.2. PROFIBUS Converter/Repeater P-2-1.3. PROFIBUS Gateway P-3-1.4. PROFIBUS Remote I/O Modules P-4-1.5. PROFIBUS I/O Unit P-5-1 Overview.1. Overview PROFIBUS (Process Field Bus) is a

More information

BUSHINGS: GENERAL INFORMATION

BUSHINGS: GENERAL INFORMATION BUSHINGS: GENERAL INFORMATION 1.0 Electrical characteristics (Ir = rated current; Ur = rated voltage) 1.1Standard insulation levels Rated voltage Ur kv (r.m.s.) 1 3,6 12 24 36 52 One minute power frequency

More information

S201-C2. Miniature Circuit Breaker - S200-1P - C - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

S201-C2. Miniature Circuit Breaker - S200-1P - C - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions. ABB Miniature Circuit Breaker - S200-1P - C - 2 ampere General Information Extended Product Type Product ID 2CDS251001R0024 EAN 40167795225 Catalog Description Long Description Miniature Circuit Breaker

More information

Fittings & Accessories

Fittings & Accessories Fittings & Accessories Adalet offers a range of fittings and accessories for use in general purpose or industrial locations. These fittings and accessories are used in conjunction with our industrial electrical

More information

Technical Data Sheet SONOFLOW CO.55 V1.0

Technical Data Sheet SONOFLOW CO.55 V1.0 Technical Data Sheet SONOFLOW CO.55 V1.0 The sensor series SONOFLOW CO.55 V1.0 designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a

More information

System Multiplexer / Permissive Module

System Multiplexer / Permissive Module System Multiplexer / (Cat 2030-MLXxxx-SYSx) ATTETIO: Hazardous Voltage or other forms of energy could be present. To avoid serious injury or death: rior to beginning the installation and wiring process,

More information

SUN VALLEY STOVE COMPANY

SUN VALLEY STOVE COMPANY LO HI ON PILOT LO HI ON PILOT SUN VALLEY STOVE COMPANY VENT-FREE NATURAL GAS STOVE HEATER ILLUSTRATED PARTS BREAKDOWN MSVFBNR 1 2 6 21 3 7 4 21 11 22 9 12 23 10 13 OFF 1 17 24 14 16 17 1 19 OFF 12 OWNER

More information

DLD channels PRO LINE Device Manual FW 1.0

DLD channels PRO LINE Device Manual FW 1.0 Tel: 032230 30 10 order@ledlab.se Rev. 20170309 pag. 1/38 FEATURES Output: 12 channels BUSSEQUENCERFADERDIMMERDRIVER Input: DC 12/24/48 Vdc (Supply voltage range 10,8Vdc 53,5Vdc) BUS Command: DMX512ARDM,

More information

General Information. Ordering. Popular Downloads. Dimensions. Technical

General Information. Ordering. Popular Downloads. Dimensions. Technical S201M-B6 Products Low Voltage Products and Systems Modular DIN Rail Products Miniature Circuit Breakers MCBs General Information Extended Product Type: S201M-B6 Product ID: 2CDS271001R0065 EAN: 4016779549424

More information

Tilkoblingsklemmer. Produktnavn Serie OTL, 1 polt, 2 tilkoblinger 1,5 50mm 2. Ouneva group

Tilkoblingsklemmer. Produktnavn Serie OTL, 1 polt, 2 tilkoblinger 1,5 50mm 2. Ouneva group FDV DOKUMENTASJON Nr.: 061 Rev.: Dato: 5.1.2016 Produktspesifikasjon Tilkoblingsklemmer Produktnavn Serie OTL, 1 polt, 2 tilkoblinger 1,5 50mm 2 Anvisning for drift Ingen Vedlikehold Produktet er vedlikeholdsfritt

More information

Mounting and Wiring VMA1200 Series Controllers

Mounting and Wiring VMA1200 Series Controllers Technical Bulletin Issue Date July 1, 2003 Mounting and Wiring VMA1200 Series Controllers Mounting and Wiring VMA1200 Series Controllers...2 Introduction... 2 Key Concepts... 3 VMA Position and Orientation...

More information

TECHNICAL CHARACTERISTICS BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS

TECHNICAL CHARACTERISTICS BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS LE GLNS able glands and plastic accessories Regulatory ompliance: able Glands: EN 50262; IE 62444 Metric pitch: IE/EN 60243 PG pitch: IN 40430 ouplings and cable glands: EN 61386-1 e EN 60670-1 as applicable

More information

With extended functionality the sensors are also applicable for the detection of air bubbles.

With extended functionality the sensors are also applicable for the detection of air bubbles. Technical Data Sheet The sensor series designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a few milliseconds. With extended functionality

More information

A-dec Dental Light on an A-dec 200 Dental Chair INSTALLATION GUIDE

A-dec Dental Light on an A-dec 200 Dental Chair INSTALLATION GUIDE A-dec 57-00 Dental Light on an A-dec 00 Dental Chair INSTALLATION GUIDE Install the Dental Light CAUTION When removing or replacing covers, take care not to damage any wiring. Verify that the covers are

More information

Electrosurgical Instruments & Accessories

Electrosurgical Instruments & Accessories Electrosurgical Instruments & Accessories Our product portfolio offers a trusted range of Electrosurgery resources for Surgeons and Clinical members. & Reusable Products 2017 Bipolar Forceps & Cables Colposcopy

More information

OPTRAL CDIR TOTALLY DIELECTRIC MOISTURE PROTECTED

OPTRAL CDIR TOTALLY DIELECTRIC MOISTURE PROTECTED CDIR Breakout Cable (Up to 16 FO) Descripción cable 01. Tight Buffer Fibre (0.9 mm) 02. Aramid 03. Individual Jacket ( 2.5 mm) 04. Outer Jacket Jackets: PVC / LSZH / PE / PU / PA Totally dielectric / Direct

More information

Scalable PLC AC500 Communication AC500 PROFIBUS DP S500- I/Os Basic module

Scalable PLC AC500 Communication AC500 PROFIBUS DP S500- I/Os Basic module Scalable PLC AC500 Communication AC500 PROFIBUS DP S500- I/Os Basic module Contents PROFIBUS: General Information Configuration with PS501 Configuration with SYCON.net: PROFIBUS Master Configuration with

More information

NO: 250 / 2 NC: 250 / 1 AC 15 6) NO: 250 / 3 NC: 250 / 2 DC 13 5) NO: 24 / 1 NC: 24 / 1 DC 13 5) at 0.1 Hz. NO: 24 / 4 NC: 24 / 4 to UL 508

NO: 250 / 2 NC: 250 / 1 AC 15 6) NO: 250 / 3 NC: 250 / 2 DC 13 5) NO: 24 / 1 NC: 24 / 1 DC 13 5) at 0.1 Hz. NO: 24 / 4 NC: 24 / 4 to UL 508 PCB relays Safety relays OA 5611, OA 5612 According to DIN EN 618-1, DIN EN 618-3 With forcibly guided contacts High switching reliability due to crown contacts Low rated power consumption High mechanical

More information

Activated Transponder & Activator Instruction Manual

Activated Transponder & Activator Instruction Manual Activated Transponder & Activator Instruction Manual Westhold Corporation General Warranty Modules and other equipment ("Goods") purchased from Westhold Corporation are warranted against defects in materials

More information

Application guide. High speed migration SYSTIMAX Ultra-Low-Loss configuration guide

Application guide. High speed migration SYSTIMAX Ultra-Low-Loss configuration guide Application guide High speed migration SYSTIMAX Ultra-Low-Loss configuration guide Contents The MPO connector, MPO pins, keys and polarity 3 - Figure 1. Pinned and unpinned MPO connectors 3 - Figure 2.

More information

Technical Parameters. 10-9:9-11:7-12:12-8 & 15-16:16-14:1-13:13-2 Turn Ratios(Choke) 1:1:1:1±1% 7-5:8-4:1-3:2-6

Technical Parameters. 10-9:9-11:7-12:12-8 & 15-16:16-14:1-13:13-2 Turn Ratios(Choke) 1:1:1:1±1% 7-5:8-4:1-3:2-6 This specification sheet is to be supplied together with the samples to customers. Customers test the samples and assess the test results to determine whether these samples meet the technical requirements.

More information

44 CE - SURFACE-MOUNTING BOXES IN GW PLAST 75; GWT 650 C FOR ORDINARY JUNCTIONS TECHNICAL CHARACTERISTICS

44 CE - SURFACE-MOUNTING BOXES IN GW PLAST 75; GWT 650 C FOR ORDINARY JUNCTIONS TECHNICAL CHARACTERISTICS 44 CE - SURFACE-MOUNTING BOXES IN GW PLAST 75; GWT 650 C FOR ORDINARY JUNCTIONS Standard: EN 60670-1 (CEI 23-48); EN 60670-22 (23-94) Degree of protection: IP44; IP55; IP56 Protection against indirect

More information

IEC 309 HP. The synthesis of perfection

IEC 309 HP. The synthesis of perfection IEC 309 HP The synthesis of perfection IEC 309 HP 2 Perfection without compromise Perfection is a state of completeness and flawlessness. It's the quality of what is excellent, free of defects and with

More information

Accessories for LV AirGuard Cables Glands, Connectors and Installation Tools.

Accessories for LV AirGuard Cables Glands, Connectors and Installation Tools. Accessories for LV AirGuard Cables Glands, Connectors and Installation Tools. A Non-Potted Gland TECHNICAL DATA Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444 Mechanical Classifications*

More information

Installation Guide for ultrasonic transducers

Installation Guide for ultrasonic transducers Installation Guide for ultrasonic transducers 1 1. Welcome at systec Thank you very much for using deltawave. This document provides you with all necessary information to install the transducers accurately

More information

Adapters, Couplers and Fittings.

Adapters, Couplers and Fittings. Adapters, Couplers and Fittings www.alliedhpi.com 1 Table of Contents QUICK-CONNECT ADAPTERS AND COUPLERS Chemetron Quick-Connect Adapters 3 Chemetron Quick-Connect Adapters ISO 4 Chemetron Quick-Connect

More information

IPC-6018A. Microwave End Product Board Inspection and Test IPC-6018A. A standard developed by IPC. Supersedes IPC-6018 January 1998

IPC-6018A. Microwave End Product Board Inspection and Test IPC-6018A. A standard developed by IPC. Supersedes IPC-6018 January 1998 ASSOCIATION CONNECTING ELECTRONICS INDUSTRIES Microwave End Product Board Inspection and Test January 2002 A standard developed by IPC Supersedes IPC-6018 January 1998 2215 Sanders Road, Northbrook, IL

More information

Bronze Parallel, Cross, and Bar Taps TYPE DGF, DGG. Ordering Information. or Copper Grounding Connector

Bronze Parallel, Cross, and Bar Taps TYPE DGF, DGG. Ordering Information.   or Copper Grounding Connector TYPE DGF, DGG Copper Grounding Connector Copper grounding connector for cable to structural steel, fence posts or groundplates. DGF accommodates two conductors and DGG accommodates one conductor. L L S

More information

Companion One. Silversphere Bedside Monitoring. Wireless. Wireless Compatibility

Companion One. Silversphere Bedside Monitoring. Wireless. Wireless Compatibility Silversphere Bedside Monitoring Silversphere bedside monitoring devices allow higher-acuity residents and their caregivers to feel safe while residents are in their beds. With both active and passive alerting

More information

SlideDriver 50VF. Modbus Controlled VFD Replacement Kit (MX4210, MX4211) REQUIRED TOOLS PARTS WORK SAFELY!

SlideDriver 50VF. Modbus Controlled VFD Replacement Kit (MX4210, MX4211) REQUIRED TOOLS PARTS WORK SAFELY! SlideDriver 50VF Modbus Controlled VFD Replacement Kit (MX420, MX42) The following instructions are intended to assist the user in the installation of post-202 manufactured VFDs for use on the SlideDriver

More information

RUBBER WATERBLAST HOSES

RUBBER WATERBLAST HOSES up to 15, PSI (1 Bar) RUBBER WATERBLAST HOSES These high pressure hose assemblies combine rugged construction, dependability and safe performance. Designed specifically for waterblast applications Lightweight

More information

CITY OF WAUPACA, WISCONSIN WATER DEPARTMENT WATER SERVICE LATERAL THAWING RULES AND PROCEDURES (prepared February 24, 2015)

CITY OF WAUPACA, WISCONSIN WATER DEPARTMENT WATER SERVICE LATERAL THAWING RULES AND PROCEDURES (prepared February 24, 2015) CITY OF WAUPACA, WISCONSIN WATER DEPARTMENT WATER SERVICE LATERAL THAWING RULES AND PROCEDURES (prepared February 24, 2015) Pursuant to Wisconsin Public Service Commission 185.88 rules on Frozen Laterals:

More information

Product Guide. NH Fuse System

Product Guide. NH Fuse System Product Guide NH Fuse System NH Fuse System NH Fuse System p. 2 MULTIBLOC NH-fuse switch disconnector GP050 p. 3 to 73 MULTIVERT NH-vertical fuse switch disconnector GP088 p. 74 to 124 BSL NH-fuse rail

More information

Jun06 Rev A

Jun06 Rev A Product Specification 108-2235 15Jun06 Rev A NETCONNECT* MRJ21 Gigabit Ethernet Cable Assemblies 1. SCOPE 1.1. Content This specification covers performance, test and quality requirements for NETCONNECT*

More information

MDR-xx Microdrive User Guide

MDR-xx Microdrive User Guide MDR-xx Microdrive User Guide (Rev. 2.0) Axona Ltd Unit 4U St. Albans Enterprise Centre Long Spring, Porters Wood St. Albans, Herts, AL3 6EN United Kingdom http://www.axona.com Table of Contents Axona MDR-xx

More information

The Custom Interconnect Leader

The Custom Interconnect Leader QC Series 1.24 (31.5) 0.93 TYP (23.6) 0.180 (4.6) 0.413 (10.5) 0.112 (2.8) Figure 1: Standard 1.25" Mounting ELECTRICAL Nominal Impedance: Frequency Range: Voltage Rating: Dielectric Withstanding Voltage:

More information

CSA Z32 TESTING GUIDELINE AND PROCEDURES

CSA Z32 TESTING GUIDELINE AND PROCEDURES CSA-Z32 Testing CSA Z32 TESTING GUIDELINE AND PROCEDURES Table of Contents CSA Z32 TESTING GUIDELINE AND PROCEDURES...1 Table of Contents...1 FACILITIES REQUIRED TO MEET CSA Z32:...1 TEST #1: INSULATION

More information

Convex Array Transducer

Convex Array Transducer User Guide Type 8823 Convex Array Transducer English BB1740-C June 2012 For Professional Users Only BK MEDICAL Mileparken 34 2730 Herlev Denmark Tel.:+45 4452 8100 / Fax:+45 4452 8199 www.bkmed.com Email:

More information

Introduction to the Taylor Spatial Frame Hardware. Trademark of Smith & Nephew. Certain marks Reg. US Pat. & TM Off.

Introduction to the Taylor Spatial Frame Hardware. Trademark of Smith & Nephew. Certain marks Reg. US Pat. & TM Off. Introduction to the Taylor Spatial Frame Hardware Trademark of Smith & Nephew. Certain marks Reg. US Pat. & TM Off. What is the Taylor Spatial Frame? Next generation circular fixator capable of 6 axes

More information

Q-Sense fmri in the MRI environment

Q-Sense fmri in the MRI environment Q-Sense fmri in the MRI environment An evaluation at the Erwin L. Hahn Institute for Magnetic Resonance Imaging, and at the Institute of Diagnostic and Interventional Radiology and Neuroradiology, Essen

More information

Mini UPS and Power Sensor. Power Output Cord. Power Input Port. Switch Port

Mini UPS and Power Sensor. Power Output Cord. Power Input Port. Switch Port AVTECH Mini UPS and Power Sensor AVTECH s Mini UPS and Power Sensor (MUPS) monitors the on/off state of a power source, such as main power, a UPS, surge protector or standard wall outlet, and also provides

More information

ULTR A SERIES G7-S13

ULTR A SERIES G7-S13 ULTR A SERIES G7-S13 PROPER USAGE 1. Do not exceed weight limits of the exercise device.. If applicable, set safety stops to appropriate height. 3. If applicable, adjust seat pads, leg pads, foot pads,

More information

PB PMA Series Attachment BASE Attachment Plate model Applicable models F-PBA10-1 F-PBA15-1 F-PBA30-1 F-PBA50-1 F-PBA75-1 F-PBA100-1 F-PBA150-1

PB PMA Series Attachment BASE Attachment Plate model Applicable models F-PBA10-1 F-PBA15-1 F-PBA30-1 F-PBA50-1 F-PBA75-1 F-PBA100-1 F-PBA150-1 al Parts PB PMA Series Attachment BASE Attachment Plate model Applicable models F-PBA0- F-PBA- F-PBA0- F-PBA0- F-PBA- F-PBA00- F-PBA0- PBA0F PBAF, PBWF PBA0F, PBW0F, PMAF PBA0F, PBW0F, PMA0F PBAF, PMA0F

More information

NO: 24 / 2 NC: 24 / 2 at 0.1 Hz

NO: 24 / 2 NC: 24 / 2 at 0.1 Hz PCB Relays Safety Relay with double contacts OA 621, OA 6 According to DIN EN 618-1, DIN EN 618-3 With forcibly guided contacts High switching safety because of gold plated double contacts Clearance and

More information

Product reference. LV switch-disconnectors 3. Product panorama 9. Functions and characteristics 17. Installation and connection 47

Product reference. LV switch-disconnectors 3. Product panorama 9. Functions and characteristics 17. Installation and connection 47 Product reference LV switch-disconnectors 3 Product panorama 9 Functions and characteristics 17 Installation and connection 47 Technical details 71 IS40 to 160 78 IS250 to 630 80 IV100 to 630 (visible

More information

ULTR A SERIES G7-S51

ULTR A SERIES G7-S51 ULTR A SERIES G7-S51 PROPER USAGE 1. Do not exceed weight limits of the exercise device.. If applicable, set safety stops to appropriate height. 3. If applicable, adjust seat pads, leg pads, foot pads,

More information

AC CENTRIFUGAL FORWARD CURVED FAN 133 x 190

AC CENTRIFUGAL FORWARD CURVED FAN 133 x 190 Micromotori Elettrici Svizzera Motor Type AC CENTRIFUGAL FORWARD CURVED FAN 133 x 19 Code: 3.9775 Project code: Poles Stator Impeller Type -4 V 5/6 Hz ~ 1 1 M35 Centrifugal Forward Curved Blade double

More information

XRS-5/XRS-5CTRANSDUCER

XRS-5/XRS-5CTRANSDUCER XRS-5/XRS-5CTRANSDUCER Instruction Manual PL-590 January 2001 33455900 Rev. 2.0 RS-5 TRANSDUCER Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and

More information

Sep2018 Rev B1

Sep2018 Rev B1 Product Specification 12Sep2018 Rev B1 HD30 Series Connector System 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the TE Connectivity (TE) HD30 Series

More information

Polyester distribution boxes

Polyester distribution boxes for Zone and Zone Description have been of great advantage in many industrial plants. They offer safe protection even when they are exposed to extreme environmental conditions, aggressive chemical media

More information

LED Modules. Fortimo LED Line

LED Modules. Fortimo LED Line LED Modules Fortimo LED Line 1ft 1100lm 3R Fortimo LED Line gen 4 will enable you to upgrade your linear LED luminaires to latest high-performance technology while offering the freedom to tune and differentiate

More information

Chapter 5: Checking and Maintaining Ultrasound Equipment

Chapter 5: Checking and Maintaining Ultrasound Equipment Chapter 5: Checking and Maintaining Ultrasound Equipment Care and Cleaning (BB1564-AJ) Chapter 5: Checking and Maintaining Ultrasound Equipment 45 Ultrasound equipment requires regular checks and maintenance.

More information

Straumann Basic Guided Surgery Cassette. More than a simple cassette. A smart Guided Surgery solution.

Straumann Basic Guided Surgery Cassette. More than a simple cassette. A smart Guided Surgery solution. Straumann Basic Guided Surgery Cassette More than a simple cassette. A smart Guided Surgery solution. Guided Surgery Cassette smartly delivered The Straumann Basic Guided Surgery Cassette has been designed

More information

Patent Number: 5,837,006 Ocel et al. (45) Date of Patent: Nov. 17, 1998

Patent Number: 5,837,006 Ocel et al. (45) Date of Patent: Nov. 17, 1998 United States Patent (19) 11 USOO5837006A Patent Number: Ocel et al. (45) Date of Patent: Nov. 17, 1998 54 RETRACTION STOPFOR HELICAL FOREIGN PATENT DOCUMENTS MEDICAL LEAD ELECTRODE 0149431 7/1985 European

More information

Central Institute of Plastics Engineering & Technology (CIPET), SP- 1298, Sitapura Industrial Area, Phase III, Tonk Road, Jaipur, Rajasthan

Central Institute of Plastics Engineering & Technology (CIPET), SP- 1298, Sitapura Industrial Area, Phase III, Tonk Road, Jaipur, Rajasthan Certificate Number TC-7082 Page 1 of 14 CHEMICAL TESTING I. PLASTIC & RESINS 1. Resin, Plastic & Polymers, Raw material, Plastic Films Resistance to Sulphuric Acid Vicat Softening Temperature IS 12235-2004

More information

SDS 4.0 Tips and Tricks

SDS 4.0 Tips and Tricks SDS 4.0 Tips and Tricks Content Important information 3 SDS 4.0 Fit and Go Box overview 4 Selecting the receiver length 5 Choosing the correct earpiece for the receiver 6 Attaching / removing the retention

More information

MicroSwitcher TMS Series 6, 10, 15, 25 Watt

MicroSwitcher TMS Series 6, 10, 15, 25 Watt Features Ultraminiature AC/DC Switching Power Supply Modules Fully encapsulated Plastic Package Universal Input 85-264 VAC, 50/60 Hz High Efficiency Low Ripple and Noise Overload Protection EMI meets EN

More information

Based on the selected Content Inventory Threshold:

Based on the selected Content Inventory Threshold: PFP6X04**-UG TX6A 10 Gig Category 6A F/UTP CMP by Panduit Health Product Declaration v2.0 created via: HPDC Online Builder CLASSIFICATION: 27 10 00 PRODUCT DESCRIPTION: Category 6A, plenum (CMP), 4-pair,

More information

A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y. Rev 2/15. D a n s e r e a u

A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y. Rev 2/15. D a n s e r e a u A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y Rev 2/15 D a n s e r e a u (8 0 0 )423-5657 / WWW.DHPDENTAL.COM DANSEREAU HEALTH PRO DUCTS, INC. AM ERIC A S DENT AL EQU I PMENT COMPAN Y Dansereau

More information