Polyester distribution boxes

Size: px
Start display at page:

Download "Polyester distribution boxes"

Transcription

1 for Zone and Zone Description have been of great advantage in many industrial plants. They offer safe protection even when they are exposed to extreme environmental conditions, aggressive chemical media or high mechanical stress. The narrow sides within the enclosure hold threaded bushings for the fixing of terminal rails or mounting panels. The enclosure is mounted by means of insulated screws outside of the lid sealing gasket. These black high-quality explosion-proofed enclosures are used in hazardous areas by inflammable dust (Zone and ).The fundamental prerequisites of the protection through enclosure protection class are fulfilled with the heating up calculation as per the accompanying sheet and a separate IP protection test. EC model test certification was issued in 000 by the nominated body IBExU. Option External feet of high-quality stainless steel Components Rail-mounted terminals, terminal markers, cable glands, mounting panels, rails, type labels, labels Installation instructions The installer must make sure that the enclosure used is suitable for the corresponding field of application. This means that the marking must correspond to the classification of the Ex area. Also must the temperature class of the distribution box meet the respective requirements /A-0/0-BCS-08/ 9

2 for Zone and Zone IP distribution box / /... Ex e distribution box / /... Ex i distribution box / /... black grey /A-0/0-BCS-08/ Explosion protection Ex protection type II G Ex e II T resp. T II G Ex e II T resp. T (according to EN 009-0) II G Ex ia IIC T resp. T II G Ex ia IIC T resp. T II D Ex td A IPx T 80 C Ambient temperature ranges -0 C (- C) to +0 C at T -0 C (- C) to +0 C at T (special temperature ranges on request) -0 C (- C) to + C at T -0 C (- C) to + C at T Certification For Zone and PTB 08 ATEX 0 PTB 08 ATEX 0 For Zone and IBExU00ATEX08 IBExU00ATEX08 (further certifications on request) Germanischer LLoyd (Germany) HH HH IECEx PTB X PTB X INMETRO (Brazil) 009EC0CP00 009EC0CP00 Gost-R (Russia) POCC SI.ME 9.BO POCC SI.ME 9.BO RTN (Russia) PPC 00-0 PPC 00-0 KOSHA (Korea) 09-AVB0-00X 09-AVB0-00X NEPSI (China) GYJ00 GYJ00 Technical data Material glass-fibre reinforced polyester, EN glass-fibre reinforced polyester, EN surface resistance < 0 9 Ω surface resistance > 0 Ω halogen-free halogen-free Colour RAL 900, black RAL 000/RAL 00, grey Lid screws stainless steel, captive stainless steel, captive (other models on request) cross-head (+ -) cross-head (+ -) Standard seals EPDM -0 C to +00 C EPDM -0 C to +00 C optional silicone - C to +00 C silicone - C to +00 C Mechanical resistance impact energy Nm impact energy Nm according to EN Protection class EN 09/IEC 09 IP IP Rated voltage max. 00 V max. 00 V 9

3 IP distribution box black /... Ex e distribution box black /... Ex i distribution box black /... IP distribution box grey /... Ex e distribution box grey /... Ex i distribution box grey /... Rail-mounted terminal components/maximum number Article no. Mini-terminal AKZ WDU. WDU. bl WDU mounting Terminals mounting Terminals mounting Terminals mounting Terminals mounting Terminals rail per rail rail per rail rail per rail rail per rail rail per rail / / / / / / / / / / / / / / / / / /08-BCS-08/ / /

4 IP distribution box black /... IP distribution box grey /... Ex e distribution box black /... Ex e distribution box grey /... Ex i distribution box black /... Ex i distribution box grey /... A Cable glands/maximum number C D B Article no. Side M x. M x. M x. M0 x. M0 x. M x. M x. M0 x. M0 x. M x. extended extended / A/B / A/B / A/B / A/B /090 A/B /0 A/B /090 A/B /090 A/B /0 A/B /090 A/B /090 A/B /0 A/B /0 A/B /0 A/B /0 A/B /0 A/B C/D /08-BCS-08/ /0 A/B C/D /0 A/B Each enclosure side wall has only a limited number of gland entries to ensure the mechanical stability of the enclosure. 98

5 IP distribution box black /... IP distribution box grey /... Ex e distribution box black /... Ex e distribution box grey /... Ex i distribution box black /... Ex i distribution box grey /... External dimensions, earth bars, mounting panels Article no. External dimensions in mm Earth bars Mounting panel Polyester enclosure Length Width Height Type Order no. Type Order no. Order no / 80 MK / 0 MK / 0 MK / 90 MK / QS LS /0 0 0 QS LS / QS LS / QS LS / QS LS / QS LS / QS LS /0 0 0 QS LS /0 0 0 QS LS / QS LS / QS LS / QS LS / QS LS /08-BCS-08/ / QS LS

IECEx Certificate of Conformity CESI

IECEx Certificate of Conformity CESI Description of the equipment: Luminaries (pendant lighting fixtures) series EV.., EW.., EWA.., are used in hazardous area, indoor and/or outdoor, where inflammable or explosive vapours gas or dust are

More information

747 Series Stopper Plugs Cable Gland Accessories Flameproof.

747 Series Stopper Plugs Cable Gland Accessories Flameproof. 747 Series Stopper Plugs Flameproof. Class I, Groups, A, B, C, D Type 4X; Ex d II Component Equipment Stopper plug is designed for use from the outside of the Idea for use on flameproof electrical equipment

More information

Accessories for LV AirGuard Cables Glands, Connectors and Installation Tools.

Accessories for LV AirGuard Cables Glands, Connectors and Installation Tools. Accessories for LV AirGuard Cables Glands, Connectors and Installation Tools. A Non-Potted Gland TECHNICAL DATA Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444 Mechanical Classifications*

More information

SWITCHGEAR PBD. fuse bases

SWITCHGEAR PBD. fuse bases SWITCHGEAR PBD fuse bases designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links ENERGY SAFELY SWITCHED SWITCHGEAR

More information

SWITCHGEAR PBD. fuse bases

SWITCHGEAR PBD. fuse bases SWITCHGEAR PBD fuse bases designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links ENERGY SAFELY SWITCHED SWITCHGEAR

More information

ADAPTER IECEx-ATEX, RNC, IP66 / 68, NICKEL PLATED BRASS

ADAPTER IECEx-ATEX, RNC, IP66 / 68, NICKEL PLATED BRASS ADAPTER IECEx-ATEX, RNC, IP66 / 68, NICKEL PLATED BRASS Anamet IECEx-ATEX adapter fitting, type RNC and RAC, nickel plated brass Type RNC IECEx-ATEX approved 45 or 90 nickel plated brass adapter, male

More information

C O M P R E H E N S I V E S A F E T Y W I T H A T E X B Y C O N T R O L W E L L

C O M P R E H E N S I V E S A F E T Y W I T H A T E X B Y C O N T R O L W E L L C O M P R E H E N S I V E S A F E T Y W I T H A T E X B Y C O N T R O L W E L L The current international regulations for machine manufacturers (94/9/EC) and operators (99/9/EC) prescribe high safety levels.

More information

Description. Specifications and Ordering Information Proximitor Sensor / interface module/ VDC Housings

Description. Specifications and Ordering Information Proximitor Sensor / interface module/ VDC Housings Specifications and Ordering Information Proximitor Sensor / interface module/ VDC Housings R Description Although Proximitor and interface are rugged by design, these units and their electrical connections

More information

Technical Data Sheet SONOFLOW CO.55 V1.0

Technical Data Sheet SONOFLOW CO.55 V1.0 Technical Data Sheet SONOFLOW CO.55 V1.0 The sensor series SONOFLOW CO.55 V1.0 designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a

More information

Features CONSTANT WATTAGE AUTOTRANSFORMER 1.9 SQ FT Lamp Included 0 MOGUL BASE HIGH PRESSURE SODIUM

Features CONSTANT WATTAGE AUTOTRANSFORMER 1.9 SQ FT Lamp Included 0 MOGUL BASE HIGH PRESSURE SODIUM GAM671L48I2 250W HPS Flood Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category GAM671L48I2 Appleton/Oz Gedney Floodlight, Mogul Base High Pressure Sodium Lamp; Lamp

More information

type AKS and ESM Introduction

type AKS and ESM Introduction Temperature sensors type AKS and ESM Introduction Temperature sensors AKS and ESM are temperature dependent resistance sensors. The sensor unit consists of a platinum element the resistance value of which

More information

RJA RJA. Welded cabinet with demountable side panels and back panel, IP 20, loading capacity 600 kg

RJA RJA. Welded cabinet with demountable side panels and back panel, IP 20, loading capacity 600 kg 0 0 0 0 0 1 1 0 0 1 0 0 0 1 1 1 1 0 1 0 1 0 1 0 1 1 1 1 Welded cabinet with demountable side panels and back panel, IP 20, loading capacity kg 37 Strenghtened skeleton Cold-rolled steel 1,3 mm. Fringe

More information

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit > A Higher Level of Performance Data Sheet Centurion Guided Radar CGR Series For more information, please visit > www.hawkmeasure.com / Dimensions Centurion Guided Wave Radar Radar Principle of Operation

More information

All dimensions are in mm. Plug: Coding Pin: HOODS TOP ENTRY HOODS. NPT Part # NP NP 10.

All dimensions are in mm. Plug: Coding Pin: HOODS TOP ENTRY HOODS. NPT Part # NP NP 10. HA 3&4 Plugs & Receptacles HA 3&4 Housings: Single Lever on Base SCREW TERMINATED INSERTS HA 3 HA 4 All dimensions are in mm. HA 3 HA 4 Plug: 10.40 10.4310 Receptacle: 10.40 10.43 Coding Pin: 10.4513 TOP

More information

44 CE - SURFACE-MOUNTING BOXES IN GW PLAST 75; GWT 650 C FOR ORDINARY JUNCTIONS TECHNICAL CHARACTERISTICS

44 CE - SURFACE-MOUNTING BOXES IN GW PLAST 75; GWT 650 C FOR ORDINARY JUNCTIONS TECHNICAL CHARACTERISTICS 44 CE - SURFACE-MOUNTING BOXES IN GW PLAST 75; GWT 650 C FOR ORDINARY JUNCTIONS Standard: EN 60670-1 (CEI 23-48); EN 60670-22 (23-94) Degree of protection: IP44; IP55; IP56 Protection against indirect

More information

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0 The sensor series SONOFLOW CO.55/xxx V2.0 designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a few milliseconds. For applications on

More information

RLS /M MX SERIES

RLS /M MX SERIES The RLS/M MX series of burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above

More information

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit > A Higher Level of Performance Data Sheet Centurion Guided Radar CGR Series For more information, please visit > www.hawkmeasure.com / Dimensions Centurion Guided Wave Radar Radar Principle of Operation

More information

Vibration Limit Switch liquiphant S FTL 70, FTL 71

Vibration Limit Switch liquiphant S FTL 70, FTL 71 Technical Information TI 354F/00/en Vibration Limit Switch liquiphant S FTL 70, FTL 71 Level limit switch for all liquids. Version for high medium temperatures. Suitable for use in explosion hazardous

More information

RLS /M MX SERIES

RLS /M MX SERIES RLS/M burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above all, more flexible.

More information

Company. Our. Our product range consists of the following groups:

Company. Our. Our product range consists of the following groups: Our Company Bimed begun in 1978 as a manufacturer of medical and mechanical components. Today Bimed is a family owned organization with more than 300 people and a 20,000 square meter facility. The Istanbul,

More information

Areamaster 250/400 Integrally Ballasted Floodlights 100 W to 400 W HID For hazardous and marine locations.

Areamaster 250/400 Integrally Ballasted Floodlights 100 W to 400 W HID For hazardous and marine locations. Lighting HID NEC/CEC ENCLOSED AND GASKETED CLASS/ZONE RATED FLOODLIGHT Applications Powerful, efficient weatherproof lighting for medium and large areas such as: Pulp and paper mills Processing plants

More information

RLS/E-EV MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES

RLS/E-EV MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES The RLS/E-EV MX series of burners covers a firing range from 350 to 2400 kw, and they have been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil

More information

2017-07-26 Annex 01 to Certificate IECEx LCI 07.0015 X issue 11 FULL EQUIPMENT DESCRIPTION Electromagnetic control valve with 2, 3, 4 or 5 channels. xxx (1) NF xxx (2) (1) without symbol xxx : aluminum

More information

RLS/BP MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES. RLS 300/BP MX 600/ kw RLS 400/BP MX 800/ kw DUAL FUEL.

RLS/BP MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES. RLS 300/BP MX 600/ kw RLS 400/BP MX 800/ kw DUAL FUEL. RLS/BP MX series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above all,

More information

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type ABB MS132-6.3 Manual Motor Starter General Information Extended Product Type Product ID MS132-6.3 1SAM350000R1009 EAN 4013614400094 Catalog Description Long Description MS132-6.3 Manual Motor Starter The

More information

With extended functionality the sensors are also applicable for the detection of air bubbles.

With extended functionality the sensors are also applicable for the detection of air bubbles. Technical Data Sheet The sensor series designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a few milliseconds. With extended functionality

More information

Enclosures & Storage

Enclosures & Storage ON-LINE Enclosures & Storage - contents 51 Electrical / Industrial Enclosures 1172 1193 Industrial 1193 Electrical 1200 53 Knobs, Hinges, Latches & Locks 1217 54 Component Storage & Cases 1257 1192 OM

More information

Applications. Projected Area: 1.9 Sq. Ft. Dimensions in Inches/Millimeters

Applications. Projected Area: 1.9 Sq. Ft. Dimensions in Inches/Millimeters NEC/CEC: Applications Powerful, efficient weatherproof lighting for medium and large areas such as: Shopping malls Parking lots Sports areas New-car lot lighting Security lighting Industrial process lighting

More information

RL/B MZ SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL RL 300/B MZ RL 400/B MZ. 600/ kw 1000/ kw

RL/B MZ SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL RL 300/B MZ RL 400/B MZ. 600/ kw 1000/ kw RL/B MZ series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above all, more

More information

WNK5 Series High Precision Pressure Transmitter

WNK5 Series High Precision Pressure Transmitter WNK5 Series High Precision Pressure Transmitter WNK5 series pressure transmitter is the high performance pressure transmitters provided by nhui WNK Electronic Engineering Co., Ltd. It transforms the physical

More information

Mechanically actuated valves

Mechanically actuated valves Mechanically actuated valves /2-5/2 spool valves with /8 NPT threaded ports Installation in any position Comprehensive range of actuations, direct or servo-piloted Special versions on request Materials

More information

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type ABB Manual Motor Starter General Information Extended Product Type Product ID 1SAM250000R1008 EAN 4013614320316 Catalog Description Long Description Manual Motor Starter The manual motor starter (also

More information

TECHNICAL CHARACTERISTICS

TECHNICAL CHARACTERISTICS 40 CDi - PROTECTED DECORATIVE ENCLOSURES - IP40 even with open door Impact : IK 08 Heat : thermo-pressure with ball 70 C e: IP40 even with open door guaranteed thanks to flush-mounting wall installation,

More information

Miniature Circuit Breaker - S200-1P - B - 2 ampere. acc. to IEC / 400 V AC acc. to IEC V AC

Miniature Circuit Breaker - S200-1P - B - 2 ampere. acc. to IEC / 400 V AC acc. to IEC V AC ABB Miniature Circuit Breaker - S200-1P - B - 2 ampere General Information Extended Product Type S201-B2 Product ID 2CDS251001R0025 EAN 4016779612944 Catalog Description Miniature Circuit Breaker - S200-1P

More information

General Information. Ordering. Popular Downloads. Dimensions. Products Low Voltage Products and Systems Circuit Breakers Manual Motor Starters

General Information. Ordering. Popular Downloads. Dimensions. Products Low Voltage Products and Systems Circuit Breakers Manual Motor Starters MS132-1.6-HKF1-11 Products Low Voltage Products and Systems Circuit Breakers Manual Motor Starters Products Low Voltage Products and Systems Control Products Manual Motor Starters Manual Motor Starters

More information

Round Duct Slot Diffusers Model SKD-13

Round Duct Slot Diffusers Model SKD-13 April 2010 Round Duct Slot Diffusers Round Duct Slot Diffusers Model SKD-13 Features Steel Construction 1 to 14 Slots or 1 to 4 slots Duct diameters of Ø150mm to Ø900mm Cylinder Inner Deflectors Swivel

More information

3. Dimensions, weights Placement and Assembly Pressure drops Noise data Material... 14

3. Dimensions, weights Placement and Assembly Pressure drops Noise data Material... 14 These technical specifications state a row of manufactured sizes and models of smoke extraction dampers - single (further only dampers) SEDS-L. It is valid for production, designing, ordering, delivery,

More information

S201-Z2. Miniature Circuit Breaker - S200-1P - Z - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

S201-Z2. Miniature Circuit Breaker - S200-1P - Z - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions. ABB Miniature Circuit Breaker - S200-1P - Z - 2 ampere General Information Extended Product Type Product ID S201-Z2 2CDS251001R0278 EAN 40167795054 Catalog Description Long Description Miniature Circuit

More information

12 EEx d-conduit Material

12 EEx d-conduit Material 12 EEx d-conduit Conduit Fittings Conduit fittings, BMF, with female/male union Series Nominal Ordering code Weight RN2095 BMF 1 1 /2" NPT 461 557 0 0,15 BMF 2 3 461 558 0 0,20 BMF 3 1" NPT 461 559 0 0,28

More information

Keylock switches for PCB

Keylock switches for PCB lock switch for PCB General data lock switch for PCB mounting. Matching with the RS 76 full-travel keyswitch and the RF 15 and RF 19 short-travel keyswitch. Content lock switch IP5, MICROMEC - 18 lock

More information

Side Channel R ing Blower

Side Channel R ing Blower Side Channel R ing Blower ------------------------------------- INSTRUCTION MNUL ------------------------------------ RB20../ 30../ 40../ 50../ 60 / 80.. SERIES CONTENT PGE 1. SFETY REQUIREMENT... 1 2.

More information

S202M-K2UC. Miniature Circuit Breaker - S200MUC - 2P - K - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

S202M-K2UC. Miniature Circuit Breaker - S200MUC - 2P - K - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions. ABB Miniature Circuit Breaker - S00MUC - P - K - ampere General Information Extended Product Type Product ID S0M-KUC CDS7061R077 EAN 4013614433146 Catalog Description Long Description Miniature Circuit

More information

Exchangeable Thermocouple Probes

Exchangeable Thermocouple Probes 106 Exchangeable Thermocouple Probes For each application, ebro provides the right thermometer and also offers a wide selection of precise and robust probes for the following thermometers: TTX 120 (see

More information

aks bed concepts for the day-to-day nursing routine for homecare and in-patient applications

aks bed concepts for the day-to-day nursing routine for homecare and in-patient applications 84 aks bed concepts for the day-to-day nursing routine for homecare and in-patient applications Simple knee bend (aks L4) Knee bend with foot elevation Foot end lowering Low entry bed aks care beds Standard

More information

Datasheet BR Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors

Datasheet BR Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors Datasheet BR Series /CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors NEW Compared to traditional fuse installation, the /CSA C22.2 No.5-02, UL1077/CSA

More information

Article No. see price AT4/11-2/I/S ,3 3,7 6 mm Zw = 4,9 mm AT4/11-S/I/S AT4/11-2/IA/S AT4/11-S/IA/S

Article No. see price AT4/11-2/I/S ,3 3,7 6 mm Zw = 4,9 mm AT4/11-S/I/S AT4/11-2/IA/S AT4/11-S/IA/S 06/014 AT 4 Oiltight Contact N.O. = normally open N.C. = normally closed f = safety function with positively opening contacts to IEC/EN 60 947-5-1 Contact Sequence U closed u open Zw = positive opening

More information

S201-C2. Miniature Circuit Breaker - S200-1P - C - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

S201-C2. Miniature Circuit Breaker - S200-1P - C - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions. ABB Miniature Circuit Breaker - S200-1P - C - 2 ampere General Information Extended Product Type Product ID 2CDS251001R0024 EAN 40167795225 Catalog Description Long Description Miniature Circuit Breaker

More information

Liquid level transmitter Type AKS 41 / 41U REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Liquid level transmitter Type AKS 41 / 41U REFRIGERATION AND AIR CONDITIONING. Technical leaflet Liquid level transmitter Type AKS 41 / 41U REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3

More information

Exchangeable Thermocouple Probes

Exchangeable Thermocouple Probes 118 Temperature Exchangeable Thermocouple Probes Exchangeable Thermocouple Probes For each application, ebro provides the right thermometer and also offers a wide selection of precise and robust probes

More information

General Information. Ordering. Popular Downloads. Dimensions. Technical

General Information. Ordering. Popular Downloads. Dimensions. Technical S201M-B6 Products Low Voltage Products and Systems Modular DIN Rail Products Miniature Circuit Breakers MCBs General Information Extended Product Type: S201M-B6 Product ID: 2CDS271001R0065 EAN: 4016779549424

More information

Installation Guide for ultrasonic transducers

Installation Guide for ultrasonic transducers Installation Guide for ultrasonic transducers 1 1. Welcome at systec Thank you very much for using deltawave. This document provides you with all necessary information to install the transducers accurately

More information

Axle Counting Cable Accessories

Axle Counting Cable Accessories Axle Counting Cable Accessories Cable Joint Kits Earth Bond Kits Moisture Barrier Kits Disaster Recovery Joint Kits Gapping Kits For Electrified & Non Electrified Railway Infrastructure Approval; Network

More information

Stax Disposable Depth Filters

Stax Disposable Depth Filters USD 2758 Stax Disposable Depth Filters Featuring Seitz AKS Activated Carbon Media Highest Efficiency in Adsorption and Design Powdered activated carbon (PAC) is widely used in the pharmaceutical industry

More information

Instruction Manual. DSRn. Density & Sound Velocity Transducers

Instruction Manual. DSRn. Density & Sound Velocity Transducers Instruction Manual DSRn Density & Sound Velocity Transducers Instruction Manual DSRn Density & Sound Velocity Transducers While every precaution has been taken in the preparation of this document, Anton

More information

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications Data Sheet 10/63-6.47-EN Rev. C PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

More information

2YEARS. three-phase kVA. Digital voltage stabiliser Orion Plus. Standard features. Voltage stabilisation PC selectable output voltage

2YEARS. three-phase kVA. Digital voltage stabiliser Orion Plus. Standard features. Voltage stabilisation PC selectable output voltage «WARRANTY«WARRANTY«WARRANTY«WARRANTY 2YEARS Digital stabiliser Standard features Voltage stabilisation PC selectable output Independent phase control Frequency 50/60Hz ±5% Admitted load variation Up to

More information

TECHNICAL CHARACTERISTICS BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS

TECHNICAL CHARACTERISTICS BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS LE GLNS able glands and plastic accessories Regulatory ompliance: able Glands: EN 50262; IE 62444 Metric pitch: IE/EN 60243 PG pitch: IN 40430 ouplings and cable glands: EN 61386-1 e EN 60670-1 as applicable

More information

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113 ata sheet ON/OFF zone valves (PN 16) MZ 112, MZ 11 escription MZ 112 / 2-port valve N15-N2 MZ 112 / 2-port valve N40-N50 MZ 11 / -port valve The ON / OFF zone valves type MZ 112 and MZ 11 are typical used

More information

RLS/M MZ SERIES. Modulating Dual Fuel Burners FIRING RATES DUAL FUEL

RLS/M MZ SERIES. Modulating Dual Fuel Burners FIRING RATES DUAL FUEL The RLS/M MZ series of burners covers a fi ring range from 550 to 2460 kw, and they have been designed for use in hot or superheated water boilers, hot air or steam generators, diathermic oil boilers.

More information

Fittings & Accessories

Fittings & Accessories Fittings & Accessories Adalet offers a range of fittings and accessories for use in general purpose or industrial locations. These fittings and accessories are used in conjunction with our industrial electrical

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the

More information

EPIC CONNECTORS. STA Series

EPIC CONNECTORS. STA Series STA Series The STA inserts with solid spring designed contacts are used extensively in the construction of devices, in control units, laboratories, and withdrawable unit design. These inserts are available

More information

MS MS Manual Motor Starter. Generell informasjon. Ordering. Popular Downloads. Dimensions. Technical MS Extended Product Type

MS MS Manual Motor Starter. Generell informasjon. Ordering. Popular Downloads. Dimensions. Technical MS Extended Product Type ABB Manual Motor Starter Generell informasjon Extended Product Type Product ID 1SAM451000R1015 EAN 401614486098 Catalog Description Long Description Manual Motor Starter MS165 is a compact and powerful

More information

RLS /E-EV MX SERIES

RLS /E-EV MX SERIES RLS 300 800/E-EV MX SERIES RLS/E-EV MX series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier,

More information

THS74/75 Industrial Temperature & Humidity Transmitter. Operation Manual

THS74/75 Industrial Temperature & Humidity Transmitter. Operation Manual THS74/75 Industrial Temperature & Humidity Transmitter Operation Manual 1. Features 2. Security considerations 3. Installation 4. Connection 5. Display and LED instruction 6. Software setting and calibration

More information

Preparation and Installation of the SANITRX / SANITRX LP (IS) Rupture Disc for Use With Industry Standard Ferrules

Preparation and Installation of the SANITRX / SANITRX LP (IS) Rupture Disc for Use With Industry Standard Ferrules Preparation and Installation of the SANITRX / SANITRX LP (IS) Rupture Disc for Use With Industry Standard Ferrules GEP-6063 Rev. T 102335 Ref. I.D.: 12978 WARNING USER SHOULD READ AND THOROUGHLY UNDERSTAND

More information

HRM Series PCB Power Relays

HRM Series PCB Power Relays Features: SPCO contacts. Sealed to allow washing after flow soldering. Specifications: Coil Data: Nominal Voltage Nominal Power consumption : 3V dc to 24V dc. : 540mW to 720mW. Contact Data: Contact Arrangement

More information

RLS /E MX SERIES

RLS /E MX SERIES RLS 310 610/E MX SERIES The RLS/E-MX series of burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier,

More information

BU 0,6/1(1,2)kV P17 Power cable, Unarmoured MGT/EPR/EVA. Standards applied. No inner covering. (Additional tapes may be applied) Armour/screen

BU 0,6/1(1,2)kV P17 Power cable, Unarmoured MGT/EPR/EVA. Standards applied. No inner covering. (Additional tapes may be applied) Armour/screen Page 1 of 5 Fire resistant, flame retardant halogen-free power cable. Mud resistant BU 0,6/1(1,2)kV MGT/EPR/EVA NEK TS 606 CodeP17 Operating temperature : 90 C Operating Voltage : 0,6/1(1,2)kV Application

More information

IEC 309 HP. The synthesis of perfection

IEC 309 HP. The synthesis of perfection IEC 309 HP The synthesis of perfection IEC 309 HP 2 Perfection without compromise Perfection is a state of completeness and flawlessness. It's the quality of what is excellent, free of defects and with

More information

RLS/M MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES. RLS 68/M MX 200/ kw RLS 120/M MX. 300/ kw RLS 160/M MX

RLS/M MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES. RLS 68/M MX 200/ kw RLS 120/M MX. 300/ kw RLS 160/M MX Low NOx Modulating Dual Fuel Burners RLS/M MX SERIES The RLS/M MX series of burners covers a fi ring range from 350 to 1840 kw, and they have been designed for use in low or medium temperature hot water

More information

KA 164F/24/ae/ liquiphant M FTL 50 H- ######## 7 #, FTL 51 H- ######## 7 # Level Limit Switch. Endress+Hauser. The Power of Know How

KA 164F/24/ae/ liquiphant M FTL 50 H- ######## 7 #, FTL 51 H- ######## 7 # Level Limit Switch. Endress+Hauser. The Power of Know How KA 164F/24/ae/11.01 52015422 liquiphant M FTL 50 H- ######## 7 #, FTL 51 H- ######## 7 # Level Limit Switch Endress+Hauser The Power of Know How IMPORTANT NOTICE RETURN AUTHORIZATION POLICY Endress+Hauser

More information

Easy assembly with standard tools. Fully insulated for direct mounting to steel panels

Easy assembly with standard tools. Fully insulated for direct mounting to steel panels Cam-Lok J Series Connectors or NEMA 4 Cam-Lok J Series Connectors are specifically designed to meet the needs of demanding portable applications. J Series Plugs and Receptacles are the proven industry

More information

Product Guide. NH Fuse System

Product Guide. NH Fuse System Product Guide NH Fuse System NH Fuse System NH Fuse System p. 2 MULTIBLOC NH-fuse switch disconnector GP050 p. 3 to 73 MULTIVERT NH-vertical fuse switch disconnector GP088 p. 74 to 124 BSL NH-fuse rail

More information

LKH-10. Connections for FSS and DMSS R1/8"(BSP) male thread.

LKH-10. Connections for FSS and DMSS R1/8(BSP) male thread. . kyhe Premium Pump ky LK Centrifugal Pump Applications he LK pump is a highly efficient and economical centrifugal pump, which meets the requirements of sanitary applications and thus gentle product treatment

More information

lighting system 2014

lighting system 2014 LIGHTING lighting system 2014 GEWISS GROUP GEWISS is an international leader in the production of systems and components for low voltage electrical installations. The fact that development is seen as a

More information

HPS MILLENNIUM GENERAL PURPOSE MEDIUM VOLTAGE Distribution

HPS MILLENNIUM GENERAL PURPOSE MEDIUM VOLTAGE Distribution HPS MILLENNIUM GENERAL PURPOSE MEDIUM VOLTAGE Distribution TRANSFORMERS 2.5 KV to 5KV Class Dry Type Single Phase and Three Phase Medium Voltage Energy Efficient Guidelines... 254 Energy Efficient Guidelines

More information

kythe Premium Pump LKH Centrifugal Pump

kythe Premium Pump LKH Centrifugal Pump . kyhe Premium Pump LK Centrifugal Pump Applications he LK pump is a highly efficient and economical centrifugal pump, which meets the requirements of sanitary and gentle product treatment and chemical

More information

Fortimo LED Square. Datasheet

Fortimo LED Square. Datasheet LED Square 380 mm 5000 lm HV1 Datasheet Fortimo LED Square Fortimo LED Square systems consist of white light LED modules with square outer dimensions delivering high energy efficiency and high quality

More information

Piping technology steel

Piping technology steel model no. page model no. page model no. page model no. page model no. page Megapress with SC-Contur Piping technology steel 1 ZM_F2_int_en_20170201_065731_5.pdf 1 01.02.2017 07:37:33 Press connector system

More information

Catalogue for Measuring Technology 2009 / Bulletin E

Catalogue for Measuring Technology 2009 / Bulletin E Industry Chemistry Pharmaceutical Catalogue for Measuring Technology 2009 / 2010 Bulletin E-05-0409 Wireless Temperature Monitoring Logger EBI 25 Pharmaceutical Chemistry Industry NEW EBI 25 Temperature

More information

Central Institute of Plastics Engineering & Technology (CIPET), SP- 1298, Sitapura Industrial Area, Phase III, Tonk Road, Jaipur, Rajasthan

Central Institute of Plastics Engineering & Technology (CIPET), SP- 1298, Sitapura Industrial Area, Phase III, Tonk Road, Jaipur, Rajasthan Certificate Number TC-7082 Page 1 of 14 CHEMICAL TESTING I. PLASTIC & RESINS 1. Resin, Plastic & Polymers, Raw material, Plastic Films Resistance to Sulphuric Acid Vicat Softening Temperature IS 12235-2004

More information

JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA

JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA TYPICAL APPLICATIONS All general loads, indoors or outdoors, including lighting, industrial & commercial Schools Hospitals Factories Office

More information

UNIBOX II III & IV. Exclusive CD edition March 2006

UNIBOX II III & IV. Exclusive CD edition March 2006 Exclusive CD edition March 2006 UniBox II and III: Fibre-optic Solutions for Fixed Connections The ready-to-install splice modules for the UniBox II and III combine the advantages of the UniBox family

More information

The Custom Interconnect Leader

The Custom Interconnect Leader QC Series 1.24 (31.5) 0.93 TYP (23.6) 0.180 (4.6) 0.413 (10.5) 0.112 (2.8) Figure 1: Standard 1.25" Mounting ELECTRICAL Nominal Impedance: Frequency Range: Voltage Rating: Dielectric Withstanding Voltage:

More information

BA 213F/24/ae/ liquiphant M FTL 50, FTL 51. Level Limit Switch. Endress+Hauser. The Power of Know How

BA 213F/24/ae/ liquiphant M FTL 50, FTL 51. Level Limit Switch. Endress+Hauser. The Power of Know How BA 213F/24/ae/04.02 52005008 liquiphant M FTL 50, FTL 51 Level Limit Switch Endress+Hauser The Power of Know How IMPORTANT NOTICE RETURN AUTHORIZATION POLICY Endress+Hauser must pre-approve and assign

More information

Gewässer Umwelt Schutz

Gewässer Umwelt Schutz Gewässer Umwelt Schutz GmbH CUW Oil protector Assembly instructions 2 Foreword Always study this assembly instruction manual before Installation and initial operation. This assembly instruction manual

More information

BUSHINGS: GENERAL INFORMATION

BUSHINGS: GENERAL INFORMATION BUSHINGS: GENERAL INFORMATION 1.0 Electrical characteristics (Ir = rated current; Ur = rated voltage) 1.1Standard insulation levels Rated voltage Ur kv (r.m.s.) 1 3,6 12 24 36 52 One minute power frequency

More information

BS 5467 PVC. stranded / Class 2 0,387 0,268 0,193 0,153 0,124 0,099 0,075. Insulation resistance Min. MΩxkm Individual conductor 1000 Test voltage

BS 5467 PVC. stranded / Class 2 0,387 0,268 0,193 0,153 0,124 0,099 0,075. Insulation resistance Min. MΩxkm Individual conductor 1000 Test voltage BS 5467 PVC Cable Instrument Cable Standard BS 5467 Voltage 06/1KV Description Copper, Multi Core, XLPE-, Armour, PVC Sheath Cable type BS 5467 Electrical data a 20ºC Conductor size Nom mm² 1,5 2,5 4 6

More information

Surge Arrestor. System The low-voltage surge arrestors are equipped with metaloxide varistors installed in robust and aging-resistant ceramic

Surge Arrestor. System The low-voltage surge arrestors are equipped with metaloxide varistors installed in robust and aging-resistant ceramic As a specialist for safety interfaces, EFEN provides surge arrestors for power distribution grids that respond to power surges within nanoseconds, thereby reliably preventing damage. System The low-voltage

More information

ST SERIES. design, development, production made in Germany

ST SERIES. design, development, production made in Germany ST SERIES design, development, production made in Germany ST 01 - Crunch Bench ST 02 - Push-up Bars ST 03 - Pull-up Bars ST 04 - Back Bench ST 05 - Balance Board ST 06 - Stretching Bars SE ST 01 - Crunch

More information

LED light engines LED linear / area. Module ELA G1 SNC Modules ELA ESSENCE

LED light engines LED linear / area. Module ELA G1 SNC Modules ELA ESSENCE Module ELA G1 SNC Modules ELA ESSENCE Product description Edgelit panel for direct recessed mount and surface or suspended mount with accessories Two luminous flux range variants 2,8 or 3,8 lm For suspended

More information

Tilkoblingsklemmer. Produktnavn Serie OTL, 1 polt, 2 tilkoblinger 1,5 50mm 2. Ouneva group

Tilkoblingsklemmer. Produktnavn Serie OTL, 1 polt, 2 tilkoblinger 1,5 50mm 2. Ouneva group FDV DOKUMENTASJON Nr.: 061 Rev.: Dato: 5.1.2016 Produktspesifikasjon Tilkoblingsklemmer Produktnavn Serie OTL, 1 polt, 2 tilkoblinger 1,5 50mm 2 Anvisning for drift Ingen Vedlikehold Produktet er vedlikeholdsfritt

More information

BM, BMhp. Lenntech. Lenntech. Booster modules 50/60 Hz. Tel Fax.

BM, BMhp. Lenntech. Lenntech. Booster modules 50/60 Hz. Tel Fax. GRUNDFOS DATA BOOKLET BM, BMhp Booster modules 5/6 z Lenntech info@lenntech.com Tel. +31-152-61-9 www.lenntech.com Fax. +31-152-616-289 Lenntech BM, BMhp Table of contents 1. Performance ranges 3 BM, 5

More information

Typ 1 19" electronic cabinet without front and rear door Features

Typ 1 19 electronic cabinet without front and rear door Features Standard cabinets NOVASTAR Typ 1 1" electronic cabinet without front and rear door Features Free choice of door- and rear door combination All uprights (front and rear) with 1" cut-outs Flush cladding

More information

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL 1 2 Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...

More information

RBL High-pressure AISI 316L stainless steel. For all fluids

RBL High-pressure AISI 316L stainless steel. For all fluids RBL High-pressure AISI 316L stainless steel For all fluids Connections in high-pressure circuits carrying corrosive liquids and gases... Applications - High-pressure hydrogen circuits - High-pressure circuits

More information