BD FACSCanto II. Tel :

Size: px
Start display at page:

Download "BD FACSCanto II. Tel :"

Transcription

1 BD FACSCanto II Tel :

2 BD FACSCanto II BD FACSCanto 03 BD FACSCanto 13 Surface Markers.. 22 DNA Analysis FACSDiva

3 BD FACSCanto II BD FACSCanto II 488nm 20mw 633nm 17mw 6~ % 120 ul/min 10,000 events/sec BD FACSCanto II 3

4 1.1 BD FACSCanto II BD FACStation FACSCanto II 4

5 1.2 Fluidics Sample injection tube (SIT) aspirator arm flow cell SIT SIT flow cell tubing SIT aspirator arm aspirator arm bar SIT tube guide SIT (Loader ) tube eject cylinder (Loader ) tube sensor SIT bal seal access Bal seal BD FACSCanto II 5

6 SIT SIT SIT SIT BD FACSDiva SIT Acquisition Dashboard SIT Flush Checkbox SIT FACSCalibur 3 ml Flow Cell 6

7 1.3 Optics BD FACSCanto II Excitation Optics 1-3 FACSCanto II BD FACSCanto II nm mw Coherent R Sapphire TM FITC, PE, PE-Texas Red, PerCP, PerCP-Cy5.5, PE-Cy7,PI JDS Uniphase TM HeNe APC,APC-Cy7 ( ) BD FACSCanto II 7

8 1.3.2 Collection Optics ( 1-3) 4-2 FACSCanto ( 4-2 ) Longpass DM PMT PMT PMT bandpass Blue A 750~810 nmblue B 670~730nmBlue D 564~606nmBlue E 515~545nmBlue F 488nm 8

9 photodiode ( 1-2) ( 4-2 ) PMT Position LP Filter nm BP or LP Filters Fluorochromes nm 488 Laser Blue A: /60 PE-Cy7 Blue B: LP PerCP, PerCP-Cy5.5 Blue C: 610 Blank filter N.A Blue D: /42 PE Blue E: /30 FITC Blue F: Blank filter 488/10 SSC 633 Laser Red A: /60 APC-Cy7 Red B: 685 Blank filter N.A Red C: Blank filter 660/20 APC BD FACSCanto II 9

10 1.4 Electronics PMT BD FACSCanto II BD FACSCanto User s Guide Signal detection Power Panel Port or Button System Power FACSCanto II Power Out FACSCanto II Communication cable System AC power plug System circuit breaker 10

11 1.4.2 Acquisition Indicator Lights BD FACSCanto II 11

12 FACSFlow 10 5 FACS Shutdown 5 FACSClean BD FACSCanto BD FACSDiva 12

13 1.5.2 FACSCanto II Off Circuit Breaker On Powering Off Condensation Trap 60~70psi 50psi BD ( ) BD FACSCanto II 13

14 BD FACSCanto II BD FACSCanto II FACSCanto II BD FACSCanto II Clinical or FACSDiva BD PC Pentium R IV 1GB RAM 40GB Windows XP Professional (US-English) 17 BD FACSCanto II Clinical Software version 2.1 or above Instrument QC, Lymphocyte subset TBNK, HLA-B27, Stem Cell Enumeration BD FACSDiva version 5.0 or above BD FACSDiva Data Manager 14

15 Cytometer > Fluidics Startup OK BD FACSCanto II BDIS ( )Enter BD FACSDiva 5. Instrument 6. Instrument Instrument Connected Instrument FACSFlow Instrument Disconnected FACSDiva 7. : Shutdown solution Sheath buffer System Prime -- Bubble filter purge Degas flow cell 5~10 BD FACSCanto II 15

16 Instrument > Automatic Cleaning FACSDiva FACSDiva Automatic Clean Automatic Clean 8. OK : For Diva Instrument Remaining warmup time 7:27 The system is ready

17 2.2 (Controls in Instrument Frame) Fluid Level Indicators BD FACSDiva FACSFlow 17% 34% 51% 68% shutdown cleaning 20% FACSFlow FACSFlow ( ) ( ) FACSFlow <17% >83% FACSFlow 0% >99% Laser Tab Window Extension FSC Area Scaling BD FACSCanto II 17

18 Status Tab 2.3 Acquisition Dashboard Next Tube Acquire Data Record Data list mode data Restart Acquire Record SIT Flush SIT 18

19 Flow Rate Low 10 µl /min Medium 60 µl /min High: 120 µl /min Fluidics Startup 2. 55~65 Psi 3. 1X10 6 cells/ml 0.5 ml 4. FALCON Fluidics Shutdown BD FACS Shutdown solution 1. 3 ml FACSClean 10%Bleach 2. Basic controls Acquire Data 3. High Flow Rate Acquire 5 5 Acquire 4. FACSClean 3 ml dh2o BD FACSCanto II 19

20 5. Acquisition controls Acquire High Flow Rate Acquire Acquire Fluidics Shutdown 7. Cytometer > Fluidics Shutdown OK OK Automatic Cleaning FACSDiva Fluidics Shutdown 1 ml SIT 8. dh2o 9. 1/ Condensation Trap 20

21 2.6 FACSCanto II Clean Flow Cell.. Instrument/Clean Modes/Clean Flow Cell.. 3 ml FACSClean FACSClean fluidics startup fluidics shutdown BD FACSCanto II 21

22 De-Gas or Bubble Filter Purge CV Instrument > Cleaning Modes > De-gas Flow Cell.. Instrument > Cleaning Modes > Bubble Filter Purge.. Priming Instrument > Cleaning Modes > Prime After Tank Refill.. OK (Long Clean) Long Clean FACSClean FACS shutdown 75 FACSClean >275 ml >1,100 ml Instrument > Cleaning Modes > Long Clean

23 2.7 FACSCanto II BD FACS 7-color setup beads Cat. No Rainbow fluorescent particles Cat. No Nile Red fluorescent particle Cat. No BD FACSFlow sheath fluid Cat. No BD FACS cleaning solution Cat. No BD FACS shutdown solution* Cat. No House hold bleach for waste 5mL polystyrene test tubes (BD Falcon ) uncapped, 125 per bag BD Cat. No capped, 125 per bag BD Cat. No capped, 25 per bag BD Cat. No with cell-strainer cap BD Cat. No *BD FACS shutdown solution BD FACSCanto II 23

24 Surface Markers BD FACSDivia Experiment Global Sheet 24

25 Surface Markers Instrument Setting ( ) 3.1 BD FACSDivia 1 2 BD FACSDivia 3 View View>>Reset positions Browser ( ) >> >> >> (Folder>>Experiment>>Specimen>>Tube BD FACSCanto II 25

26 5 Folder Folder 6 Experiment Folder Experiment Experiment>>New Experiment Experiment templates Blank Experiment with Sample Tube 7 FACSDiva Blank Experiment with Pop-up Menu 2-color exp Enter 26

27 8 Blank Experiment with Sample Tube Specimen_001 Specimen Specimen Specimen Tube_001 Specimen_001 Tube color exp Instr Settings ( ) Inspector Parameters Parameters PerCP-Cy5-5 PE-Cy7 APC APC-Cy7 FITC PE Parameters Add or Delete FITC EGFP Alexa 488 PerCP-Cy5-5 PerCP PI 3.4 Global Sheet BD FACSCanto II 27

28 10 Global Sheet1 Dot Plot 1 FSC-A vs SSC-A 2 FITC-A vs PE-A 3.5 Optimize Settings FSC SSC Surface Markers CD3 FITC 3 CD4 PE FSC SSC 11 Instument Tube_ Basic Controls Acquire Record 28

29 FSC SSC Voltage Instrument Parameters FSC SSC FSC SSC Acquire 13 Basic Controls Acquire Instrument Threshold FSC 14 Global Sheet1 FSC-A vs SSC-A P1 P1 BD FACSCanto II 29

30 15 Shift Show Population P1 P1 Instument Voltage 16 Tube_001Basic Controls Acquire Record Instrument Parameter Acquisition Controls Acquire FITC-A vs PE-A quadrants 30

31 17 FITC Tube_001 Basic Controls Acquire PE-%FITC unstained(q3) FITC alone(q4) PE-A Mean 18 PE Tube_001 Basic Controls Acquire FITC-%PE unstained(q3) PE alone(q1) FITC-A Mean BD FACSCanto II 31

32 19 Experiment Instr Settings Inpector Print Typical Instrument Setting for 2-color experiment on FACSCanto II Specimen_001_Tube_001 Specimen_001 Inspector Sample_0831 Enter 32

33 21 Tube_001 Inspector Name CD3_CD4_001 Enter Diva 22 Labels Lable ( ) FITC Label CD3 23 Lable ( ) Events to record Stopping gate Storage gete Global sheet1 FSC/SSC P1 populations marker quadrants 24 CD3 FITC/CD4 PE Sample_001 CD3_CD4_001 Acquisition Controls Acquire P1 Acquisition Controls Record BD FACSCanto II 33

34 25 10, Acquisition Controls Next Tube Tube CD3_CD4_002 CD3_CD4_002 CD3 FITC/CD4 PE Acquisition Controls Acquire P1 Record 26 34

35 DNA Analysis DNA BD FACSDivia DNA Analysis Global Sheet ModFit LT BD FACSCanto II 35

36 DNA Instrument Setting ( ) 4.1 BD FACSDivia 1 2 BD FACSDivia For Diva 4.X.X or 5.X.X : Instrument>Instrument Configuration DNA PI DAPI Duplicate DNA_001 OK Parameter Add PI Blue (Laser) D(Detector) OK Set 36

37 3.2.1 For Diva 6.0 or above : Cytometer>View Configurations DNA PI DAPI Configuration Duplicate DNA_ Edi Ctrl Parameters PE PI Blue D Set Configuration OK 4.2 DNA Analysis 7 Folder Folder 8 Experiment Folder Experiment Experiment>>New Experiment Experiment templates Blank Experiment with Sample Tube BD FACSCanto II 37

38 9 FACSDiva Blank Experiment with Inspector DNA_001 Enter 10 DNA_001 Specimen_001 Specimen Specimen Specimen Tube_001 Specimen_001 Tube DNA_001 Instr Settings ( ) Inspector Parameters Parameters PerCP-Cy5-5 PE-Cy7 APC APC-Cy7 FITC PE 12 Parameters Add or Delete PE P 38

39 13 PI LIN PI-W 4.4 Global Sheet 14 Global Sheet1 Dot Plot 1 FSC-A vs SSC-A 2 PI-W vs PI-A Histogram 3 PI-A histogram BD FACSCanto II 39

40 4.5 Optimize Settings PI=5,000 DNA FSC SSC optional DNA Unstimulated PI Stimulated Positive PI PI 15 Tube_001 Instrument Threshold PI PI 5, DNA Low 40

41 17 Basic Controls Acquire Record PI Voltage G0 PI-A 50 X Global Sheet1 PI-W vs PI-A Single Cells P1 P1 FSC SSC 19 Instrument Parameters FSC SSC FSC SSC FSC SSC Voltage Jurkat Acquire BD FACSCanto II 41

42 20 PI-A Show Population P1 PI-A P1Jurkat 21 Basic Controls Acquire Instrument Threshold PI 22 DNA Experiment Instr Settings Inpector Print 42

43 Specimen_001_Tube_001 Specimen_001 Inspector Sample_0831 Ente 26 Tube_001 Inspector Name PI_001 Enter Diva 27 Labels Experiment>Experiment Layout Experiment Layout Lable ( ) 28 Experiment Layout Acquisition ( ) PI_001 Events to Record 20,000 OK BD FACSCanto II 43

44 29 Acquisition Controls Low Stopping gate Storage gete 30 Global sheet1 PI-W/PI-A P1 P1 31 PI Sample_001 PI_001 Acquisition Controls Acquire P1 Acquisition Controls Record 20, Acquisition Controls Next Tube Tube PI_002 PI_002 Acquisition Controls Acquire P1 Record 33 44

45 DNA ModFit LT Cell Cycle DNA_001 File>>Export>>FCS files 35 FCS2.0 BD FACSCanto II 45

46 36 Cell Cycle G0/1-S-G2/M ModFit LT 46

47 FACSDiva FACSDiva BD FACSDvia Global sheet BDISEnter BD FACSDiva Experiment>>New Experiment Experiment templates Blank Experiment BD FACSCanto II 47

48 2 File>>Import>>FCS Files D:/BD EXPORT/EXPERIMENT/6 Color cocktails Global Worksheet 3 New Global Worksheet Global Sheet2 Analysis 48

49 4 Analysis 1 FSC-A vs SSC-A 2 FITC-A vs PE-A 5 tube_001 Analysis FSC-A X FSC-H BD FACSCanto II 49

50 6 snap-to-gate FSC-A SSC-A Diva 7 FITC-A PE-A Show Populations P1 8 FITC-A PE-A P1 50

51 9 Create statistics View 10 Edit Statistics View 11 P1 Q1~4 BD FACSCanto II 51

52 12 Statistics Analysis File >> Print CSV File >> Export >> statistics 52

53 15 test1 Save Shift 17 File >> Export >> Worksheet Elements 18 Expor BD FACSCanto II 53

54 P Color LnL Inspector Analysis 21 6 Color LnL Batch Analysis Print Statistics START 54

55 22 test 1 Save BD FACSCanto II 55

56 5.7 Log Out 23 - FACSDiva 24 File >> Quit File >> Log Out Quit 5.8 Excel 25 Excel >> Microsoft Excel 26 D:\BD Export\Statistic CSV 56

57 27 30 BD FACSCanto II 57

58 (PMTs 4-2 ) (nm) (nm) Fluorescein, FITC (Blue E) Phycoerythrin-R, PE (Blue D) Peridinin-chlorophyll, (Blue B) PerCP PerCP-Cy (Blue B) Cy-Chrome (Blue B) PE-Texas Red (B or D) PE-Cy (Blue B) PE-Cy (Blue A) Allophycocyanine (Red C) APC-Cy (Red A) Ethidium Bromide 510 (+ds DNA) 595 (Blue D) Propidium Iodide 536 (+ds DNA) 623 (B or D) Acridine Orange 480 (+ DNA) (+ RNA) 520 (Blue E) 650 (Blue B) Thiazole Orange 509 (+ RNA) 533 (Blue E) Viability Propidium Iodide (B or D) YOPRO (Blue E) Acridine Orange (Blue E) 7-AAD (Blue B) DiO-C6 (3) (Blue E) Mitochondrial Rhodamine (Blue E) ph BCECF-AM 488 Ratio 520/620 SNARF1-AM 514 Ratio 587/640 Fluo4-AM (Blue E) Calcium Green (Blue E) Fura Red (Blue B) H2O2 sensitive Dihydrorhodamine (Blue E) DCFH-DA (Blue E) O2- radical sensitive Hydroethidine (Blue D) Esterase sensitive Fluorescein -DA (Blue E) 58

59 Optical Configurations nm mw Coherent R Sapphire TM FITC, PE, PE-Texas Red, PerCP, PerCP-Cy5.5, PE-Cy7, PI JDS Uniphase TM HeNe APC, APC-Cy7 Point Source iflex Pacific Blue, AmCyan ( ) PMT Position LP Filter nm BP or LP Filters Fluorochromes nm 488 Laser Blue A: /60 PE-Cy7 Blue B: LP PerCP, PerCP-Cy5.5 Blue C: 610 Blank filter N.A Blue D: /42 PE Blue E: /30 FITC Blue F: Blank filter 488/10 SSC 633 Laser Red A: /60 APC-Cy7 Red B: 685 Blank filter N.A Red C: Blank filter 660/20 APC 405 Laser Viiolet A: /50 AmCyan Violet B: Blank filter 450/50 Pacific blue BD FACSCanto II 59

60 ( 5-3 ) PMT Position LP Filter nm BP or LP Filters Fluorochromes nm 488 Laser Blue A: /60 PE-Cy7 Blue B: LP PerCP, PerCP-Cy5.5 Blue C: /23 PE-Texas Red Blue D: /42 PE Blue E: /30 FITC Blue F: Blank filter 488/10 SSC 633 Laser Red A: /60 APC-Cy7 Red B: /21 Alexa Fluor-700 Red C: Blank filter 660/20 APC 60

BD FACSCanto. BD FACSCanto. 488nm 20mw 633nm 17mw 0.1% 120uL/min 10,000events/sec. BD Biosciences 1

BD FACSCanto. BD FACSCanto. 488nm 20mw 633nm 17mw 0.1% 120uL/min 10,000events/sec. BD Biosciences 1 BD FACSCanto BD FACSCanto 488nm 20mw 633nm 17mw 6 2 0.1% 120uL/min 10,000events/sec BD Biosciences 1 BD FACSCCanto BD FACStation 1.1 FACSCanto 1.1.1 Fluidics Sample injection tube Aspirator arm flow cell

More information

BD FACSCanto II. A proven platform for maximum reliability and the highest quality results

BD FACSCanto II. A proven platform for maximum reliability and the highest quality results BD FACSCanto II A proven platform for maximum reliability and the highest quality results A proven platform for maximum reliability and the highest quality results Built on more than 25 years of BD experience

More information

BD OneFlow LST Application Guide

BD OneFlow LST Application Guide BD OneFlow LST Application Guide IVD 23-16165-00 7/2014 EC REP Becton, Dickinson and Company BD Biosciences 2350 Qume Drive San Jose, CA 95131 USA Benex Limited Pottery Road, Dun Laoghaire, Co. Dublin,

More information

Application Information Bulletin: Human NK Cells Phenotypic characterizing of human Natural Killer (NK) cell populations in peripheral blood

Application Information Bulletin: Human NK Cells Phenotypic characterizing of human Natural Killer (NK) cell populations in peripheral blood Application Information Bulletin: Human NK Cells Phenotypic characterizing of human Natural Killer (NK) cell populations in peripheral blood Christopher A Fraker, Ph.D., University of Miami - Miami, Florida

More information

Application Note. Productivity and Efficiency of 6-Color BD Multitest and BD Trucount Technologies for Enumeration of Lymphocyte Subsets

Application Note. Productivity and Efficiency of 6-Color BD Multitest and BD Trucount Technologies for Enumeration of Lymphocyte Subsets Sept 27 Productivity and Efficiency of 6-Color BD Multitest and BD Trucount Technologies for Enumeration of Lymphocyte Subsets Phillip Ruiz, MD, PhD*, Michael J. Borowitz, MD, PhD**, Henok Tilahun***,

More information

BD Multitest IMK Kit

BD Multitest IMK Kit BD Multitest IMK Kit 50 Tests Catalog No. 340503 50 Tests with BD Trucount Tubes Catalog No. 340504 IVD 2016 BD. BD, the BD Logo and all other trademarks are property of Becton, Dickinson and Company.

More information

BD CBA on the BD Accuri C6: Bringing Multiplexed Cytokine Detection to the Benchtop

BD CBA on the BD Accuri C6: Bringing Multiplexed Cytokine Detection to the Benchtop BD CBA on the BD Accuri C6: Bringing Multiplexed Cytokine Detection to the Benchtop Maria Dinkelmann, PhD Senior Marketing Applications Specialist BD Biosciences, Ann Arbor, MI 23-14380-00 Cellular Communication

More information

WHO Prequalification of Diagnostics Programme PUBLIC REPORT

WHO Prequalification of Diagnostics Programme PUBLIC REPORT WHO Prequalification of Diagnostics Programme PUBLIC REPORT Product: BD FACSCount Instrument System with FACSCount Control Kit and BD FACSCount Reagent Kit (Absolute CD4+, CD8+, and CD3+ Counts) Number:

More information

Concentration Estimation from Flow Cytometry Exosome Data Protocol

Concentration Estimation from Flow Cytometry Exosome Data Protocol Concentration Estimation from Flow Cytometry Exosome Data Protocol 1. STANDARD CURVE Create a standard curve for the target exosome by plotting the mean fluorescence (y axis) against the protein concentration

More information

A step-by-step approach to build and analyze a multicolor panel

A step-by-step approach to build and analyze a multicolor panel Analyze A step-by-step approach to build and analyze a multicolor panel For Research Use Only. Not for use in diagnostic or therapeutic procedures. Alexa Fluor is a registered trademark of Life Technologies

More information

Graphical User Interface for Windows for MCM Module

Graphical User Interface for Windows for MCM Module Page 1 of 8 Installation:- Please ensure that you have the latest updated GUI and download the GUIv.x.x.x.x.ZIP from our website. Extract the folder to a temporary location (These files can be deleted

More information

Multi-Parameter Apoptosis Assay Kit

Multi-Parameter Apoptosis Assay Kit Multi-Parameter Apoptosis Assay Kit Catalog Number KA1335 5 x 96 assays Version: 05 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Background... 3 Principle of the Assay...

More information

ab Exosome Isolation and Analysis Kit - Flow Cytometry, Cell Culture (CD63 / CD81)

ab Exosome Isolation and Analysis Kit - Flow Cytometry, Cell Culture (CD63 / CD81) Version 1 Last updated 26 September 2018 ab239682 Exosome Isolation and Analysis Kit - Flow Cytometry, Cell Culture (CD63 / For the isolation and analysis of exosome from cell culture. This product is

More information

Gladstone Institutes, University of California (UCSF), San Francisco, USA

Gladstone Institutes, University of California (UCSF), San Francisco, USA Fluorescence-linked Antigen Quantification (FLAQ) Assay for Fast Quantification of HIV-1 p24 Gag Marianne Gesner, Mekhala Maiti, Robert Grant and Marielle Cavrois * Gladstone Institutes, University of

More information

Supplementary Table 1

Supplementary Table 1 Supplementary Table 1 Flow Cytometry Antibodies Antibody Fluorochrome Clone Vendor CD45 PE-cyanine 7 30-F11 D ioscience CD3 Pacific lue 17A2 iolegend (San Diego, CA) CD11b APC M1/70 iolegend (San Diego,

More information

B and T-Cells. CD8+ Cytotoxic T Cells

B and T-Cells. CD8+ Cytotoxic T Cells Sony Biotechnology Inc. Application Data, SA38 Spectral Analyzer TBNK Panel Page 1 TBNK panel on the SA38 Spectral Analyzer TBNK (B-Cell, T-Cell, and natural killer cells) panels are frequently used to

More information

BD Phosflow T Cell Activation Kit

BD Phosflow T Cell Activation Kit BD Phosflow T Cell Activation Kit Instruction Manual Catalog No. 560750 ii BD Phosflow T Cell Activation Kit The information in this guide is subject to change without notice. BD Biosciences reserves the

More information

A simple and rapid flow cytometry-based assay to identify a competent embryo prior to embryo transfer.

A simple and rapid flow cytometry-based assay to identify a competent embryo prior to embryo transfer. A simple and rapid flow cytometry-based assay to identify a competent embryo prior to embryo transfer. Eva Pallinger 1, Zoltan Bognar 2,5,7, Jozsef Bodis 3,4,7, Timea Csabai 2,5,7, Nelli Farkas 6 Krisztina

More information

Technical Resources. BD Immunocytometry Systems. FastImmune Intracellular Cytokine Staining Procedures

Technical Resources. BD Immunocytometry Systems. FastImmune Intracellular Cytokine Staining Procedures FastImmune Intracellular Cytokine Staining Procedures BD has developed protocols for the detection of intracellular cytokines in activated lymphocytes and in activated monocytes. The procedures have been

More information

Sleep Apnea Therapy Software Clinician Manual

Sleep Apnea Therapy Software Clinician Manual Sleep Apnea Therapy Software Clinician Manual Page ii Sleep Apnea Therapy Software Clinician Manual Notices Revised Notice Trademark Copyright Sleep Apnea Therapy Software Clinician Manual 103391 Rev A

More information

Technical Bulletin. Technical Information for Quidel Molecular Influenza A+B Assay on the Bio-Rad CFX96 Touch

Technical Bulletin. Technical Information for Quidel Molecular Influenza A+B Assay on the Bio-Rad CFX96 Touch Technical Bulletin Technical Information for Quidel Molecular Influenza A+B Assay on the Bio-Rad CFX96 Touch Quidel Corporation has verified the performance of the Quidel Molecular Influenza A+B Assay

More information

Sleep Apnea Therapy Software User Manual

Sleep Apnea Therapy Software User Manual Sleep Apnea Therapy Software User Manual Page ii Notices Revised Notice Trademark Copyright 103392 Rev B Published February 8, 2013 and supersedes all previous versions. The information contained in this

More information

The Annexin V Apoptosis Assay

The Annexin V Apoptosis Assay The Annexin V Apoptosis Assay Development of the Annexin V Apoptosis Assay: 1990 Andree at al. found that a protein, Vascular Anticoagulant α, bound to phospholipid bilayers in a calcium dependent manner.

More information

BD Flow Cytometry Reagents Multicolor Panels Designed for Optimal Resolution with the BD LSRFortessa X-20 Cell Analyzer

BD Flow Cytometry Reagents Multicolor Panels Designed for Optimal Resolution with the BD LSRFortessa X-20 Cell Analyzer Multicolor Panels Designed for Optimal Resolution with the BD LSRFortessa X-2 Cell Analyzer Proper multicolor panel design takes into account fluorochrome brightness, antigen density, co-expression, and

More information

BD Cytometric Bead Array (CBA) Mouse Th1/Th2/Th17 Cytokine Kit

BD Cytometric Bead Array (CBA) Mouse Th1/Th2/Th17 Cytokine Kit BD Cytometric Bead Array (CBA) Mouse Th1/Th2/Th17 Cytokine Kit Instruction Manual Catalog No. 560485 ii Mouse Th1/Th2/Th17 Cytokine Kit 2009, Becton, Dickinson and Company. All rights reserved. No part

More information

a Beckman Coulter Life Sciences: White Paper

a Beckman Coulter Life Sciences: White Paper a Beckman Coulter Life Sciences: White Paper An 8-color DuraClone IM panel for detection of Human blood dendritic cells by flow cytometry Nathalie Dupas 1, Snehita Sattiraju 2, Neha Girish 2, Murthy Pendyala

More information

x Lymphocyte count /µl CD8+ count/µl 800 Calculated

x Lymphocyte count /µl CD8+ count/µl 800 Calculated % Lymphocyte in CBC A. 50 40 30 20 10 Lymphocyte count /µl B. x10 3 2.5 1.5 C. 50 D. 1000 % CD3+CD8+ Cells 40 30 20 Calculated CD8+ count/µl 800 600 400 200 10 0 #61 #63 #64 #65 #68 #71 #72 #75 Figure

More information

CyFlow SL_3. Healthcare Immunology. Portable FCM System for Routine HIV/AIDS Monitoring of Adult and Pediatric Patients

CyFlow SL_3. Healthcare Immunology. Portable FCM System for Routine HIV/AIDS Monitoring of Adult and Pediatric Patients CyFlow SL_3 Healthcare Immunology Portable FCM System for Routine HIV/AIDS Monitoring of Adult and Pediatric Patients 01 COMPANY Flow Cytometry made in Germany New sophisticated applications and increasing

More information

In vitro human regulatory T cell expansion

In vitro human regulatory T cell expansion - 1 - Human CD4 + CD25 + CD127 dim/- regulatory T cell Workflow isolation, in vitro expansion and analysis In vitro human regulatory T cell expansion Introduction Regulatory T (Treg) cells are a subpopulation

More information

Human Progenitor Cell Enumeration by Flow Cytometry Practical Considerations

Human Progenitor Cell Enumeration by Flow Cytometry Practical Considerations Human Progenitor Cell Enumeration by Flow Cytometry Practical Considerations Bruce Briggs, M.S., S.I. (A.S.C.P.) OSU Medical Center Clinical Flow Cytometry Objectives Conceptual overview: How the Flow

More information

BD Cytometric Bead Array (CBA) Human Th1/Th2/Th17 Cytokine Kit

BD Cytometric Bead Array (CBA) Human Th1/Th2/Th17 Cytokine Kit BD Cytometric Bead Array (CBA) Human Th1/Th2/Th17 Cytokine Kit Instruction Manual Catalog No. 560484 ii Human Th1/Th2/Th17 Cytokine Kit 2009, Becton, Dickinson and Company. All rights reserved. No part

More information

Flow Cytometry Based Exosome Detection and Analysis Using the ZE5 Cell Analyzer

Flow Cytometry Based Exosome Detection and Analysis Using the ZE5 Cell Analyzer Flow Cytometry ased Exosome Detection and nalysis Using the ZE5 Cell nalyzer Yasha Talaga, Elizabeth Dreskin, Joyce Lee io-rad Laboratories, Inc. 2000 lfred Nobel Drive, Hercules C 94547 Flow Cytometry

More information

AudioConsole. User Guide. Doc. No EN/01 Part No EN

AudioConsole. User Guide. Doc. No EN/01 Part No EN AudioConsole Doc. No. 7-50-2180-EN/01 Part No. 7-50-21800-EN Copyright notice [2003], 2018 Inmedico A/S. All rights reserved. Oscilla is aregistered trademark of Inmedico A/S in the U.S.A. and/or other

More information

In vitro human regulatory T cell expansion

In vitro human regulatory T cell expansion - 1 - Human CD4 + CD25 + regulatory T cell isolation, Workflow in vitro expansion and analysis In vitro human regulatory T cell expansion Introduction Regulatory T (Treg) cells are a subpopulation of T

More information

Nature Protocols: doi: /nprot Supplementary Figure 1

Nature Protocols: doi: /nprot Supplementary Figure 1 Supplementary Figure 1 Traditional electronic gating strategy for analysing cell death based on A5-FITC and 7-AAD. a, Flow cytometry analysis showing the traditional two-stage electronic gating strategy

More information

Comprehensive evaluation of human immune system reconstitution in NSG. and NSG -SGM3 mouse models toward the development of a novel ONCO-HU

Comprehensive evaluation of human immune system reconstitution in NSG. and NSG -SGM3 mouse models toward the development of a novel ONCO-HU Comprehensive evaluation of human immune system reconstitution in NSG and NSG -SGM3 mouse models toward the development of a novel ONCO-HU xenograft model Aaron Middlebrook, 1 Eileen Snowden, 2 Warren

More information

Evaluation of a Single-Platform Technology for Lymphocyte Immunophenotyping

Evaluation of a Single-Platform Technology for Lymphocyte Immunophenotyping CLINICAL AND VACCINE IMMUNOLOGY, Oct. 2007, p. 1342 1348 Vol. 14, No. 10 1556-6811/07/$08.00 0 doi:10.1128/cvi.00168-07 Copyright 2007, American Society for Microbiology. All Rights Reserved. Evaluation

More information

LiteLink mini USB. Diatransfer 2

LiteLink mini USB. Diatransfer 2 THE ART OF MEDICAL DIAGNOSTICS LiteLink mini USB Wireless Data Download Device Diatransfer 2 Diabetes Data Management Software User manual Table of Contents 1 Introduction... 3 2 Overview of operating

More information

Detection. personal. Now, you can optimize your personal workflow. Promega instruments and reagents integrate easily.

Detection. personal. Now, you can optimize your personal workflow. Promega instruments and reagents integrate easily. personal Detection Now, you can optimize your personal workflow. Promega instruments and reagents integrate easily. An ultra-sensitive, versatile, and affordable single tube luminometer for Life Science

More information

Dosimeter Setting Device

Dosimeter Setting Device Instruction Manual Dosimeter Setting Device For Electronic Personal Dosimeter Dose-i (Unit:Sv, Version:1.05 English) WTA529748 a 1 / 38 Foreword Thank you for purchasing the Dosimeter Setting Device; a

More information

BD OneFlow LST. 20 tests per kit Catalog No

BD OneFlow LST. 20 tests per kit Catalog No BD OneFlow LST 20 tests per kit Catalog No. 658619 IVD BD, BD Logo and all other trademarks are property of Becton, Dickinson and Company. 2014 BD 7/2014 23-15586-00 Becton, Dickinson and Company BD Biosciences

More information

BD Leucocount Kit. Rx Only IVD

BD Leucocount Kit. Rx Only IVD 2/217 23-19381- IVD BD Leucocount Kit For enumeration of residual leucocytes in leucoreduced blood products 5 Tests Catalog No. 662415 217 BD. BD, the BD logo and all other trademarks are property of Becton,

More information

MATERIALS. Peptide stimulation and Intracellular Cytokine Staining- EFFECTOR 45RA PANEL

MATERIALS. Peptide stimulation and Intracellular Cytokine Staining- EFFECTOR 45RA PANEL v Peptide stimulation and Intracellular Cytokine Staining- EFFECTOR 45RA PANEL Authors S. Kutscher, A. Cosma, MATERIALS REAGENTS: - PBMCs - Culture medium - Costimulating antibodies - Peptide pools including

More information

7-AAD/CFSE Cell-Mediated Cytotoxicity Assay Kit

7-AAD/CFSE Cell-Mediated Cytotoxicity Assay Kit 7-AAD/CFSE Cell-Mediated Cytotoxicity Assay Kit Catalog Number KA1293 96 assays Version: 02 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Background... 3 Principle of

More information

Circulating Endothelial Cells and Their Clinical Significance Jaco Kraan

Circulating Endothelial Cells and Their Clinical Significance Jaco Kraan Circulating Endothelial Cells and Their Clinical Significance Jaco Kraan Department of Medical Oncology Erasmus MC Cancer Institute Rotterdam, The Netherlands ISLH 2016 - Milano, Italy Financial disclosure

More information

Peptide stimulation and Intracellular Cytokine Staining

Peptide stimulation and Intracellular Cytokine Staining v Peptide stimulation and Intracellular Cytokine Staining Authors A. Cosma, S. Allgayer MATERIALS Date 01-02-2007 REAGENTS: Version 1.0 - PBMCs - Culture medium - Costimulating antibodies - Peptide pools

More information

ab Annexin V- mfluor Blue 570 Detection

ab Annexin V- mfluor Blue 570 Detection Version 1 Last updated 26 March 2018 ab219914 Annexin V- mfluor Blue 570 Detection Reagent For the rapid, sensitive and accurate measurement of PS exposure in live cells This product is for research use

More information

SANAKO Lab 100 STS USER GUIDE

SANAKO Lab 100 STS USER GUIDE SANAKO Lab 100 STS USER GUIDE Copyright 2008 SANAKO Corporation. All rights reserved. Microsoft is a registered trademark. Microsoft Windows 2000 and Windows XP are trademarks of Microsoft Corporation.

More information

Superior Fluorescent Labeling Dyes Spanning the Full Visible Spectrum...1. Trademarks: HiLyte Fluor (AnaSpec, Inc.)

Superior Fluorescent Labeling Dyes Spanning the Full Visible Spectrum...1. Trademarks: HiLyte Fluor (AnaSpec, Inc.) Table of Contents Fluor TM Labeling Dyes Superior Fluorescent Labeling Dyes Spanning the Full Visible Spectrum....1 Fluor TM 405 Dye, an Excellent Alternative to Alexa Fluor 405 & DyLight 405....2 Fluor

More information

Use of standardized lyophilized reagents to develop a functional T- cell signature. John F. Dunne, PhD Assoc. Scientific Director BD Biosciences

Use of standardized lyophilized reagents to develop a functional T- cell signature. John F. Dunne, PhD Assoc. Scientific Director BD Biosciences Use of standardized lyophilized reagents to develop a functional T- cell signature John F. Dunne, PhD Assoc. Scientific Director BD Biosciences Functional T cell responses to tumor antigens in breast cancer

More information

For Electric Personal Dosimete Dose-i

For Electric Personal Dosimete Dose-i Instruction Manual Dosime eter Setting Device For Electric Personal Dosimete er Dose-i (Unit:rem, Version:1.05 English) Issued on March 2015 WTA529893 1 / 38 Foreword Thank you for purchasing the Dosimeter

More information

Supplementary information

Supplementary information Supplementary information Lipid peroxidation causes endosomal antigen release for cross-presentation Ilse Dingjan 1, Daniëlle RJ Verboogen 1, Laurent M Paardekooper 1, Natalia H Revelo 1, Simone P Sittig

More information

Welcome! With a little effort you can have a big effect

Welcome! With a little effort you can have a big effect Pausit version 1.9 User Guide Welcome! Copyright 2014 Pausit AB medföljer programvaran Pausit With a little effort you can have a big effect Life today, both at work and play, demands a constant fast pace,

More information

BlueBayCT - Warfarin User Guide

BlueBayCT - Warfarin User Guide BlueBayCT - Warfarin User Guide December 2012 Help Desk 0845 5211241 Contents Getting Started... 1 Before you start... 1 About this guide... 1 Conventions... 1 Notes... 1 Warfarin Management... 2 New INR/Warfarin

More information

User s Manual for Eclipse(AccuCap)

User s Manual for Eclipse(AccuCap) InnoCaption Agent Program User s Manual for Eclipse(AccuCap) VER 2.1.4 InnoCaptionAgent Ver 2.1.4 2015-10-12 InnoCaption 1 / 24 InnoCaption Agent User s Manual for Eclipse Table of Contents 1. GENERAL...

More information

Phagocytosis of FITC labelled opsonized and non-opsonized E. coli bacteria by monocytes and granulocytes in a whole blood assay

Phagocytosis of FITC labelled opsonized and non-opsonized E. coli bacteria by monocytes and granulocytes in a whole blood assay Phagocytosis of FITC labelled opsonized and non-opsonized E. coli bacteria by monocytes and granulocytes in a whole blood assay APPLICATION NOTE Author: Andreas Spittler, MD, Associate Professor for Pathophysiology

More information

The Hospital Anxiety and Depression Scale Guidance and Information

The Hospital Anxiety and Depression Scale Guidance and Information The Hospital Anxiety and Depression Scale Guidance and Information About Testwise Testwise is the powerful online testing platform developed by GL Assessment to host its digital tests. Many of GL Assessment

More information

Titrations in Cytobank

Titrations in Cytobank The Premier Platform for Single Cell Analysis (1) Titrations in Cytobank To analyze data from a titration in Cytobank, the first step is to upload your own FCS files or clone an experiment you already

More information

Mouse Th1/Th2 Cytokine CBA

Mouse Th1/Th2 Cytokine CBA BD Cytometric Bead Array Mouse Th1/Th2 Cytokine CBA Cat. No. 551287 BD Biosciences For research use only. Not for use in diagnostic or therapeutic procedures. Purchase does not include or carry any right

More information

Lu SX, 1 Na I-K, 1 Howe L, 2 McIntyre CA, 2 Sasaki D, 3 Balderas R, 3 and van den Brink MRM 1 1. BD Biosciences, San Jose, CA

Lu SX, 1 Na I-K, 1 Howe L, 2 McIntyre CA, 2 Sasaki D, 3 Balderas R, 3 and van den Brink MRM 1 1. BD Biosciences, San Jose, CA Construction of multicolor antibody panels for the flow cytometric analysis of murine thymic Lu SX, 1 Na I-K, 1 Howe L, 2 McIntyre CA, 2 Sasaki D, 3 Balderas R, 3 and van den Brink MRM 1 1 Department of

More information

ab Exosome Isolation and Analysis Kit - Flow Cytometry, Plasma

ab Exosome Isolation and Analysis Kit - Flow Cytometry, Plasma Version 1 Last updated 25 May 2018 ab228565 Exosome Isolation and Analysis Kit - Flow Cytometry, Plasma For the isolation/detection of exosomes from human plasma, urine or cell culture media. This product

More information

In vitro human regulatory T cell suppression assay

In vitro human regulatory T cell suppression assay Human CD4 + CD25 + regulatory T cell isolation, in vitro suppression assay and analysis In vitro human regulatory T cell suppression assay Introduction Regulatory T (Treg) cells are a subpopulation of

More information

Interferon γ regulates idiopathic pneumonia syndrome, a. Th17 + CD4 + T-cell-mediated GvH disease

Interferon γ regulates idiopathic pneumonia syndrome, a. Th17 + CD4 + T-cell-mediated GvH disease Interferon γ regulates idiopathic pneumonia syndrome, a Th17 + CD4 + T-cell-mediated GvH disease Nora Mauermann, Julia Burian, Christophe von Garnier, Stefan Dirnhofer, Davide Germano, Christine Schuett,

More information

Lipid Droplets Fluorescence Assay Kit

Lipid Droplets Fluorescence Assay Kit Lipid Droplets Fluorescence Assay Kit Item No. 500001 www.caymanchem.com Customer Service 800.364.9897 Technical Support 888.526.5351 1180 E. Ellsworth Rd Ann Arbor, MI USA TABLE OF CONTENTS GENERAL INFORMATION

More information

ab Exosome Isolation and Analysis Kit - Flow Cytometry, Cell culture

ab Exosome Isolation and Analysis Kit - Flow Cytometry, Cell culture Version 1 Last updated 14 March 2018 ab228564 Exosome Isolation and Analysis Kit - Flow Cytometry, Cell culture For the measurement of human exosomes in cell culture. This product is for research use only

More information

A. User s Guide. CareCenter MD Stress and Resting ECG

A. User s Guide. CareCenter MD Stress and Resting ECG 70-00533-02 A User s Guide CareCenter MD Stress and Resting ECG CARECENTER MD STRESS AND RESTING USER S GUIDE 70-00533-02 A Information in this document is subject to change without notice. Names and data

More information

Lipidomic Analysis by UPLC-QTOF MS

Lipidomic Analysis by UPLC-QTOF MS Lipidomic Analysis by UPLC-QTOF MS Version: 1 Edited by: Oliver Fiehn Summary Reagents and Materials Protocol Summary:Lipidomic analysis by UPLC-QTOF mass spectrometry Reagents and Materials: Reagent/Material

More information

Allergy Basics. This handout describes the process for adding and removing allergies from a patient s chart.

Allergy Basics. This handout describes the process for adding and removing allergies from a patient s chart. Allergy Basics This handout describes the process for adding and removing allergies from a patient s chart. Accessing Allergy Information Page 1 Recording No Known Medication Allergies Page 2 Recording

More information

EasyComp. The TPN Compatibility Software. Clinical Nutrition

EasyComp. The TPN Compatibility Software. Clinical Nutrition EasyComp The TPN Compatibility Software Clinical Nutrition Content 1. General Information 5 1.1 What is EasyComp? 4 1.2 Features and functions of EasyComp 5 1.3 IT requirements 5 t2. Starting EasyComp

More information

Sanako Lab 100 STS USER GUIDE

Sanako Lab 100 STS USER GUIDE Sanako Lab 100 STS USER GUIDE Copyright 2002-2015 SANAKO Corporation. All rights reserved. Microsoft is a registered trademark. Microsoft Windows XP, Windows Vista and Windows 7 are trademarks of Microsoft

More information

Detailed step-by-step operating procedures for NK cell and CTL degranulation assays

Detailed step-by-step operating procedures for NK cell and CTL degranulation assays Supplemental methods Detailed step-by-step operating procedures for NK cell and CTL degranulation assays Materials PBMC isolated from patients, relatives and healthy donors as control K562 cells (ATCC,

More information

Supplementary Table; Supplementary Figures and legends S1-S21; Supplementary Materials and Methods

Supplementary Table; Supplementary Figures and legends S1-S21; Supplementary Materials and Methods Silva et al. PTEN posttranslational inactivation and hyperactivation of the PI3K/Akt pathway sustain primary T cell leukemia viability Supplementary Table; Supplementary Figures and legends S1-S21; Supplementary

More information

IFN-γ Secretion Assay Detection Kit (PE) human

IFN-γ Secretion Assay Detection Kit (PE) human Miltenyi Biotec GmbH Friedrich-Ebert-Straße 68 51429 Bergisch Gladbach, Germany Phone +49 2204 8306-0 Fax +49 2204 85197 macs@miltenyibiotec.de Miltenyi Biotec Inc. 12740 Earhart Avenue Auburn CA 95602,

More information

Data Management, Data Management PLUS User Guide

Data Management, Data Management PLUS User Guide Data Management, Data Management PLUS User Guide Table of Contents Introduction 3 SHOEBOX Data Management and Data Management PLUS (DM+) for Individual Users 4 Portal Login 4 Working With Your Data 5 Manually

More information

In vitro expansion of mouse CD4 + T cells

In vitro expansion of mouse CD4 + T cells Direct ex vivo isolation, cultivation and expansion of CD4 + T cells from mouse spleen In vitro expansion of mouse CD4 + T cells Introduction CD4 + T helper (TH) cells play a central role in the adaptive

More information

Cigarette Smoke Generator

Cigarette Smoke Generator Sophisticated Life Science Research Instrumentation Cigarette Smoke Generator For Inhalation and Analytic Studies Info@TSE-Systems.com Contents Cigarette Smoke Generator Fully Automatic 3 Sensors 3 Cigarette

More information

User Manual. RaySafe i2 dose viewer

User Manual. RaySafe i2 dose viewer User Manual RaySafe i2 dose viewer 2012.03 Unfors RaySafe 5001048-A All rights are reserved. Reproduction or transmission in whole or in part, in any form or by any means, electronic, mechanical or otherwise,

More information

Table of Contents Index Next. See inside for a complete description of program functions >> Link to the Table of Contents >> Link to the Index

Table of Contents Index Next. See inside for a complete description of program functions >> Link to the Table of Contents >> Link to the Index OneTouch Diabetes Management Software User Manual Next User Manual See inside for a complete description of program functions >> Link to the Table of Contents >> Link to the Index Information in this document

More information

Rapid antigen-specific T cell enrichment (Rapid ARTE)

Rapid antigen-specific T cell enrichment (Rapid ARTE) Direct ex vivo characterization of human antigen-specific CD154+CD4+ T cell Rapid antigen-specific T cell enrichment (Rapid ARTE) Introduction Workflow Antigen (ag)-specific T cells play a central role

More information

Muse Assays for Cell Analysis

Muse Assays for Cell Analysis Muse Assays for Cell Analysis Multiple Assay Outputs for Cell Analysis Cell Health Cell Signalling Immunology Muse Count & Viability Kit Muse Cell Cycle Kit Muse Annexin V & Dead Cell Kit Muse Caspase

More information

Automated process to create snapshot reports based on the 2016 Murray Community-based Groups Capacity Survey: User Guide Report No.

Automated process to create snapshot reports based on the 2016 Murray Community-based Groups Capacity Survey: User Guide Report No. research for a sustainable future Automated process to create snapshot reports based on the 2016 Murray Community-based Groups Capacity Survey: User Guide Report No. 116 Steven Vella Gail Fuller Michael

More information

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager Quick Start Guide Step 1. Calibrate the Q-TOF LC/MS for low m/z ratios 2 Step 2. Set up a Flow Injection Analysis (FIA) method for

More information

QUICK START GUIDE SENTIERO OAE, TYMP AND AUDIOMETRY SCREENING ( and )

QUICK START GUIDE SENTIERO OAE, TYMP AND AUDIOMETRY SCREENING ( and ) QUICK START GUIDE SENTIERO OAE, TYMP AND AUDIOMETRY SCREENING (8-04-15907 and 8-04-15908) DEVICE CONNECTORS On/off button Headphones Power supply Air pump USB cable START MENU CONFIRM PRESET Label printer

More information

Dosimeter Setting Device System NRZ

Dosimeter Setting Device System NRZ User s Manual Dosimeter Setting Device System NRZ For Dosimeter NRF series (Units: msv Version:0.26 English) TA5C0903 b 1 / 50 Preface Thank you for purchasing the Dosimeter Setting Device; a product by

More information

GEX Recommended Procedure Eff. Date: 09/21/10 Rev.: D Pg. 1 of 7

GEX Recommended Procedure Eff. Date: 09/21/10 Rev.: D Pg. 1 of 7 GEX Recommended Procedure Eff. Date: 09/21/10 Rev.: D Pg. 1 of 7 NOTICE: This document is version controlled and was produced as a part of the GEX Information Program which requires that all Series 100

More information

GYMTOP USB PROFESSIONAL 20143

GYMTOP USB PROFESSIONAL 20143 GYMTOP USB PROFESSIONAL 20143 CONTENTS 1 x Gymtop USB 1 x CD Please note: please see PC requirements below. ABOUT THIS PRODUCT Can help develop users motor skills including planning Gymtop uses proprioceptors

More information

Cloud Condensation Nuclei Counter (CCN) Module

Cloud Condensation Nuclei Counter (CCN) Module Particle Analysis and Display System (PADS): Cloud Condensation Nuclei Counter (CCN) Module Operator Manual DOC-0190 A-1 PADS 2.5.6, CCN Module 2.5.1 5710 Flatiron Parkway, Unit B Boulder, CO 80301 USA

More information

Table of Contents Index Next. See inside for a complete description of program functions >> Link to the Table of Contents >> Link to the Index

Table of Contents Index Next. See inside for a complete description of program functions >> Link to the Table of Contents >> Link to the Index OneTouch Diabetes Management Software v2.3 User Manual Next User Manual See inside for a complete description of program functions >> Link to the Table of Contents >> Link to the Index Information in this

More information

Iso-inertial dynamometer

Iso-inertial dynamometer Iso-inertial dynamometer A. Equipment set up B. Data acquisition and export C. Training mode 1 P a g e A. Equipment set up 1. Connect all the devices as depicted below: 2. Launch the software by clicking

More information

Annexin V APC Assay Kit

Annexin V APC Assay Kit Annexin V APC Assay Kit Item No. 601410 www.caymanchem.com Customer Service 800.364.9897 Technical Support 888.526.5351 1180 E. Ellsworth Rd Ann Arbor, MI USA TABLE OF CONTENTS GENERAL INFORMATION 3 Materials

More information

Lionbridge Connector for Hybris. User Guide

Lionbridge Connector for Hybris. User Guide Lionbridge Connector for Hybris User Guide Version 2.1.0 November 24, 2017 Copyright Copyright 2017 Lionbridge Technologies, Inc. All rights reserved. Published in the USA. March, 2016. Lionbridge and

More information

Optimizing Intracellular Flow Cytometry:

Optimizing Intracellular Flow Cytometry: Optimizing Intracellular Flow Cytometry: Simultaneous Detection of Cytokines and Transcription Factors Presented by Jurg Rohrer, PhD, BD Biosciences 23-10780-00 Outline Introduction Cytokines Transcription

More information

Bruker D8 Discover User Manual (Version: July 2017)

Bruker D8 Discover User Manual (Version: July 2017) University of Minnesota College of Science and Engineering Characterization Facility Eulerian cradle Reference 2θ (two-theta): Detector angle (GADDS angle # 1) Bruker D8 Discover User Manual (Version:

More information

T H 1, T H 2 and T H 17 polarization of naïve CD4 + mouse T cells

T H 1, T H 2 and T H 17 polarization of naïve CD4 + mouse T cells A complete workflow for cell preparation, isolation, polarization and analysis T H 1, T H 2 and T H 17 polarization of naïve CD4 + mouse T cells Introduction Workflow CD4 + T helper (T H) cells play a

More information

Bioneer Corporation 8-11,Munpyeongseo-ro, Daedeok-gu, Daejeon 34302, Republic of Korea Tel: Fax:

Bioneer Corporation 8-11,Munpyeongseo-ro, Daedeok-gu, Daejeon 34302, Republic of Korea Tel: Fax: Bioneer Corporation 8-11,Munpyeongseo-ro, Daedeok-gu, Daejeon 34302, Republic of Korea Tel: +82-42-930-8777 Fax: +82-42-930-8688 Email: sales@bioneer.co.kr www.bioneer.co.kr Safety Warnings and Precautions

More information

DURACLONE IF BE CERTAIN ABOUT THE RESPONSE. l res. a il n c n. For Research Use Only - Not for use in Diagnostic procedures

DURACLONE IF BE CERTAIN ABOUT THE RESPONSE. l res. a il n c n. For Research Use Only - Not for use in Diagnostic procedures DURACLONE IF earch tria l res lc a om ic il n c n nio pa Yo ur BE CERTAIN ABOUT THE RESPONSE For Research Use Only - Not for use in Diagnostic procedures BE CERTAIN ABOUT THE RESPONSE The sensitive and

More information

DURACLONE RE THERE ARE EVENTS YOU CANNOT AFFORD TO MISS

DURACLONE RE THERE ARE EVENTS YOU CANNOT AFFORD TO MISS DURACLONE RE THERE ARE EVENTS YOU CANNOT AFFORD TO MISS Your clinical research trial companion For Reseach Use Only - Not for use in Diagnostic procedures THERE ARE EVENTS YOU CANNOT AFFORD TO MISS Rare

More information

Optimizing Intracellular Flow Cytometry:

Optimizing Intracellular Flow Cytometry: Optimizing Intracellular Flow Cytometry: Simultaneous Detection of Cytokines and Transcription Factors An encore presentation by Jurg Rohrer, PhD, BD Biosciences 10.26.10 Outline Introduction Cytokines

More information

Pearson r = P (one-tailed) = n = 9

Pearson r = P (one-tailed) = n = 9 8F4-Specific Lysis, % 1 UPN1 UPN3 8 UPN7 6 Pearson r =.69 UPN2 UPN5 P (one-tailed) =.192 4 UPN8 n = 9 2 UPN9 UPN4 UPN6 5 1 15 2 25 8 8F4, % Max MFI Supplementary Figure S1. AML samples UPN1-UPN9 show variable

More information