An Assessment of Organ and Effective Dose of Patients who Undertake CT Examinations in two Teaching Hospitals of Mashhad&Isfahan

Size: px
Start display at page:

Download "An Assessment of Organ and Effective Dose of Patients who Undertake CT Examinations in two Teaching Hospitals of Mashhad&Isfahan"

Transcription

1 An Assessment of Organ and Effective Dose of Patients who Undertake CT Examinations in two Teaching Hospitals of Mashhad&Isfahan *M.T.Bahreyni Toossi, **S.Mohandes Dastgherdi Medical Physics Dep., Faculty of Medicine, Mashhad University of Medical Sciences. Mashhad-Iran * ** Abstract. The relative public dose from CT examination depends on various factors and therefore its influence on the public dose from medical applications is varied widely in different societies. In Iran, little data are available in this field. In the present work, we have tried to estimate patient dose caused by routine CT examinations in four teaching hospitals. Organ and effective dose were estimated for 7 patients who underwent CT examination of brain, chest and abdomen pelvis. Four CT scanners were involved in this work. Application of CTDOSE software enabled us to compute for all patients doses to organs with the ICRP specified tissue weighting factors, Organs listed as remainder organs and some additional organs such as: lenses of eyes, heart and trunk. CT scans applied to all 7 patients who participated in this survey can be classified into three major examinations namely: brain, chest and abdomen pelvis. The results were analyzed to find out the CT machines and CT scans which can cause maximum and minimum organ and effective dose. Summary of our findings are as follows: patients who were scanned by G.E CT pace scanner in the abdomen pelvis region received maximum dose equal to.5 mgy to their U-bladder and minimum dose equal to.5 mgy to their thyroid. Maximum organ dose all in all was delivered to brain when brain scan was performed by G.E CT pace machine. Maximum effective dose (.97 msv) was produced when abdomen pelvis scans was carried out; minimum effective dose (. msv) was resulted from brain scan. Scan carried out by G.E CT pace scanner produced maximum effective dose (.5 msv), minimum effective dose (o.9 msv) was achieved when CT examination was performed by Siemens somatom.. Introduction In recent years application of a wide variety of CT examinations in diagnostic radiology has been increased sharply. Due to the nature of CT procedures it is considered as a relatively high dose technique, which could deliver much higher doses to patients in comparison to conventional radiology. The doses can often approach or exceed the levels at which the probability of cancer induction is known to be increased significantly [,]. In a 998 survey,the UK National Radiological Protection Board (NRPB) reported that % of the national collective dose from medical X-ray examinations was derived from CT-scans, although it represented only % in terms of the total number of such examinations. The NRPB has also reported that the contribution of CT examinations to national collective dose had risen up to one third in 995 and nearly to % in 998[,,,5,]. Many similar studies have been performed to estimate absorbed dose to organs and tissues of patients undergoing CT examinations in other countries. Iran has been no exception, and over past years the number of requests for CT examinations by medical professionals has gone up by many folds, but so far, non-or very little information are available as regards to the contribution of CT examinations in patient dose [,7]. In this research, for the first time in Iran, we have estimated organ and effective dose of 7 patients who undertook CT examinations in four hospitals of two major cities of Mashhad and Isfahan. When large number of patients and various organs are involved, indirect dosimetry is more appropriate. For this purpose different workers in different countries have compiled quite a few computer program. In this study and for our purpose CTDOSE software; compiled by John Le Heron; has been utilized. CTDOSE is a computer program, written to run on MSDOS computer to enable the calculation of organ doses and effective dose for CT examinations performed on a selection of common CT scanners. CTDOSE uses data files containing the results of Monte Carlo calculations performed at the National Radiological Protection Board (UK) [7,,].

2 . Materials and Methods CTDOSE requires a computer running MSDOS version. or later. It can also be run as an MSDOS task under Microsoft Windows.. Printed output from CTDOSE is text only and so any printer will do. The computer program is supplied as an executable file CTDOSE.EXE that should be placed in the same directory as the data files (named MCSET.DAT up to MCSET.DAT) and CTDI.DAT (CTDI.DAT contains a set of default values of CTDI per mas obtained during the survey of CT practice in the UK). The input of the software is divided into two parts. The first part is concerned with specifying the make and model of CT scanners. Scanning parameters are then entered to the second part of input. The rang of scanning parameters are as follows: -mas: values up to mas per slice are valid. -Slice width: values up to mm are valid. -Couch increment: values from to mm are acceptable. -CTDI/mAs: values up to mgy per mas are accepted. -Start position (mm): the base of the trunk is assigned a value of mm, and the top of the head 9mm.The software assumes that the sequence of slices is toward the head, values from -mm to 9mm are valid. -No of slices: it represents the number of slices in the region of interest []. Altogether 7 patients were selected from those who were referred during spring and summer of for their CT examinations to the radiology department of the following four hospitals (8 per hospital):imam Reza and Ghaem which are located in Mashhad, north east of Iran; Shariaty and AL-Zahra which are situated in Isfahan, in the center of Iran. Siemens somatom, GE CT 98, GE CT Max and GE CT Pace were the scanners used in Ghaem, Imam Reza, Shariaty and Al-Zahra respectively. The most common CT examinations carried out in these hospitals were: brain, chest, and abdomen-pelvis. According to the requirements dictated by the input file of CTDOSE software, scan parameters and the type of CT machine used for a particular examination had to be recorded. Therefore a questionnaire was designed to accommodate details of individual patient CT scan (table I). Table I. The questionnaire used in this research Name of hospital: Model of CT scanner: Start No of Couch Slice mas kvp Type of Name of Position Slices Increment Width Examination Patient 7 questionnaires were filled in for all examinations included in this study. Later this information were entered to the input file of the program. At this stage we were able to acquire from the output file organ dose in mgy for organs with ICRP- specified tissue weighting factors, the organs listed as the remainder organs in ICRP- and also dose to an additional organ and body regions. ICRP classifications for CTDOSE software are showed in table II [8]. Table II. ICRP classification for body organs/tissues applied to CTDOSE software ICRP Organs:,,,, Red Marrow,,,,,,,. Remainder Organs:,,,,,, Small Intestine,,,. Other organs:,,,.. Leg Reg. In addition to individual organ dose, effective dose was also computed for the relevant examination/patients. Organ and effective dose calculated for individual patient/examination were saved in separate files for further analysis.

3 . Results All 7 data files created for patients included in this research were divided into groups of equal numbers. Each group consisted files related to patients who undertook similar examination by one of the four CT scanners employed in this study. Average organ and effective dose were computed for pre-specified groups. Summary of all these calculations are presented in table III. Figures to show how the average dose to a single organ (as specified by ICRP-) is varied with the type of CT examination and also CT scanners of different model modify radiation dose to a particular organ arising from identical examinations. Dose ' mgy ' 8 FIG.. Organ doses by GE CT Max Dose ' mgy ' 8 8 FIG.. Organ doses by GE CT Pace

4 Dose 'mgy ' 8 FIG.. Organ dose by GE CT 98 5 Dose ' mgy ' FIG.. Organ Dose by Siemens Somatom

5

6 Average effective dose of all patients were also examined for the effect of CT scanner model and the prescribed CT examination (fig 5). Fig. shows that over all average effective doses of patients depends on the scanner s make and model. Average effective dose of all patients due to undertaking of brain, chest and abdomen-pelvis examinations were determined. The results are given in figure 7. EDE ' msv ' 5 GE CT MAX GE CT PACE GE CT 98 SIEMENS SOMATOM The model of scanner FIG. 5. Average effective dose caused in different examinations by different scanners..5 EDE ' msv ' GE CT MAX GE CT PACE GE CT 98 SIEMENS SOMATOM The model of scanner FIG.. Average effective dose arising from three types of examinations by different CT scanners. EDE ' msv ' BRAIN CHEST ABDOMAN-PELVIS Type of examoination FIG. 7. Average effective dose received by all patients due to three specified CT examinations.

7 . Discussion and conclusion A careful review of our results summarized in table I and fig to 7 enabled us to specify: the organs which absorb maximum and minimum dose; type of CT examinations delivering the highest and lowest dose to a particular organ; and the CT scanner which its employment will give rise to the highest over all average dose to patients. Figures to show that regardless of the scanners make and model: average organ dose to gonads, stomach,,, red marrow, bone, U bladder, skin, kidneys, small intestine, uterus, muscle and G bladder are higher for abdomen-pelvis examination., esophagus, breasts, thymus and heart receive a higher average dose when chest CT-scan is carried out. Also brain scan is responsible for higher average dose to brain and eye lenses. In figure 5 average effective dose to patients produced by different CT machines can be compared. It is clearly evident that abdomen-pelvis examination will give rise to the highest effective dose irrespective of the scanner model. Overall average effective dose of patients examined by GE CT Pace scanner is equal to.5msv; it is also as low as.9 msv for Siemens somatom. On the other hand from figure 7 it is evident that average effective dose produced by all four CT-scanners investigated in this study, is distinctly higher when patient is undertaking abdomen-pelvis scans, and is at its lowest value for brain examination. 5. References.International Commission on Radiological Protection, Managing patient dose in computed tomography. Publication 87. Annals of the ICRP,,No., Pergamon Press, Oxford and New York ().. Shrimpton, P.C.,Wall, B.F., The increasing importance of X-Ray computed tomograpy as a source of medical exposure. Radiat. Prot. Dosim., 57: -5, (995).. Shrimpton, P.C., Edvyen, S., CT scanner dosimetry. BR. J. Radiol., 7: -, (998).. Shrimpton, P.C., Jones,D.G., Hillier, M.C., Wall, B.F., Le Heron, J.C., and Faulkner, K., Survey of CT practice in the UK.(part ): Dosimetric aspects. NRPB R-9: -, (99). 5. Shrimpton, P.C., Wall, B.F., Reference dose for pediatric CT. Radiat. Prot.Dosim., 9: 9-5, ().. Wall, B.F., Shrimpton, P.C., The historical development of reference doses in diagnostic radiology. Radiat. Prot. Dosim. 8: 5-, (998). 7. Jones, D.G., Shrimpton, P.C., Survey of CT practice in the U.K (part) : Normalized organ doses calculated using Monte Carlo techniques. NRPB R-5: -9, (99). 8. Recommendations of the International Commission on Radiological Protection. Publication. Analls of the ICRP,, No.-, Pergamon Press, Oxford and New York (99). 7

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method Iran. J. Radiat. Res., 2004; 1(4): 187-194 Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method M.R. Ay 1, M. Shahriari 2, S. Sarkar 3, P.

More information

Assessment of effective dose in paediatric CT examinations

Assessment of effective dose in paediatric CT examinations Assessment of effective dose in paediatric CT examinations E. Dougeni 1,2 CL. Chapple 1, J. Willis 1, G. Panayiotakis 2 1 Regional Medical Physics Department, Freeman Hospital, Freeman Road, Newcastle

More information

Radiation Dose To Pediatric Patients in Computed Tomography in Sudan

Radiation Dose To Pediatric Patients in Computed Tomography in Sudan Radiation Dose To Pediatric Patients in Computed Tomography in Sudan Omer Osman,Saeed Medical Physics Department, ALNeelain University, Sudan Presentation outlines Introduction Objectives Materials and

More information

Radiation Dosimetry for CT Protocols

Radiation Dosimetry for CT Protocols Radiation Dosimetry for CT Protocols This document contains radiation dosimetry information from CT scans and can be used by investigators to estimate the dosimetry information required by the JRSC or

More information

CT Dose Estimation. John M. Boone, Ph.D., FAAPM, FSBI, FACR Professor and Vice Chair of Radiology. University of California Davis Medical Center

CT Dose Estimation. John M. Boone, Ph.D., FAAPM, FSBI, FACR Professor and Vice Chair of Radiology. University of California Davis Medical Center CT Dose Estimation John M. Boone, Ph.D., FAAPM, FSBI, FACR Professor and Vice Chair of Radiology 1 University of California Davis Medical Center CT Dose Estimation Introduction The CTDI Family of Metrics

More information

Conventional and spiral CT dose indices in Yazd general hospitals, Iran

Conventional and spiral CT dose indices in Yazd general hospitals, Iran Iran. J. Radiat. Res., 2006; 3 (4): 183-189 Conventional and spiral CT dose indices in Yazd general hospitals, Iran F. Bouzarjomehri 1*,M.H.Zare 2, D. Shahbazi 2 1 Department of Medical Physics, Shahid

More information

Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use?

Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use? Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use? Eva Godske Friberg * Norwegian Radiation Protection Authority, P.O. Box, Østerås, Norway Abstract.

More information

A more accurate method to estimate patient dose during body CT examinations with tube current modulation

A more accurate method to estimate patient dose during body CT examinations with tube current modulation A more accurate method to estimate patient dose during body CT examinations with tube current modulation Poster No.: C-0738 Congress: ECR 2014 Type: Scientific Exhibit Authors: A. Kawaguchi 1, Y. Matsunaga

More information

Skyscan 1076 in vivo scanning: X-ray dosimetry

Skyscan 1076 in vivo scanning: X-ray dosimetry Skyscan 1076 in vivo scanning: X-ray dosimetry DOSIMETRY OF HIGH RESOLUTION IN VIVO RODENT MICRO-CT IMAGING WITH THE SKYSCAN 1076 An important distinction is drawn between local tissue absorbed dose in

More information

Medical Physics and Informatics Original Research

Medical Physics and Informatics Original Research Medical Physics and Informatics Original Research Christner et al. Estimating Effective Dose for CT Medical Physics and Informatics Original Research FOCUS ON: Jodie A. Christner 1 James M. Kofler Cynthia

More information

Survey of patients CT radiation dose in Jiangsu Province

Survey of patients CT radiation dose in Jiangsu Province Original Article Page 1 of 6 Survey of patients CT radiation dose in Jiangsu Province Yuanyuan Zhou 1, Chunyong Yang 1, Xingjiang Cao 1, Xiang Du 1, Ningle Yu 1, Xianfeng Zhou 2, Baoli Zhu 1, Jin Wang

More information

Machine Learning Powered Automatic Organ Classification for Patient Specific Organ Dose Estimation

Machine Learning Powered Automatic Organ Classification for Patient Specific Organ Dose Estimation Machine Learning Powered Automatic Organ Classification for Patient Specific Organ Dose Estimation Junghwan Cho, Eunmi Lee, Hyunkwang Lee, Bob Liu, Xinhua Li, Shahein Tajmir, Dushyant Sahani, and Synho

More information

Managing Patient Dose in Computed Tomography (CT) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION

Managing Patient Dose in Computed Tomography (CT) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION Managing Patient Dose in Computed Tomography (CT) International Commission on Radiological Protection Information abstracted from ICRP Publication 87 Available at www.icrp.org Task Group: M.M. Rehani,

More information

Accounting for Imaging Dose

Accounting for Imaging Dose Accounting for Imaging Dose High Profile Over-exposures Lead to Growing Concern FDA issues warning in October 2009-209 patients exposed to 8 times typical dose for CT brain perfusion scan (3-4 Gy) - Some

More information

Calculation of Effective Doses for Radiotherapy Cone-Beam CT and Nuclear Medicine Hawkeye CT Laura Sawyer

Calculation of Effective Doses for Radiotherapy Cone-Beam CT and Nuclear Medicine Hawkeye CT Laura Sawyer Calculation of Effective Doses for Radiotherapy Cone-Beam CT and Nuclear Medicine Hawkeye CT Laura Sawyer Department of Medical Physics and Bioengineering, Royal United Hospital, Bath Overview Varian Acuity

More information

THE LEVEL OF COMPLIANCE OF SELECTED NIGERIAN X-RAY DEPARTMENTS TO EUROPEAN GUIDELINES ON GOOD RADIOGRAPHIC TECHNIQUES

THE LEVEL OF COMPLIANCE OF SELECTED NIGERIAN X-RAY DEPARTMENTS TO EUROPEAN GUIDELINES ON GOOD RADIOGRAPHIC TECHNIQUES IJRRAS 9 (1) October 11 www.arpapress.com/volumes/vol9issue1/ijrras_9_1_16.pdf THE LEVEL OF COMPLIANCE OF SELECTED NIGERIAN X-RAY DEPARTMENTS TO EUROPEAN GUIDELINES ON GOOD RADIOGRAPHIC TECHNIQUES Bamidele

More information

Radiation exposure of the Yazd population from medical conventional X-ray examinations

Radiation exposure of the Yazd population from medical conventional X-ray examinations Iran. J. Radiat. Res., 2007; 4 (4): 195-200 Radiation exposure of the Yazd population from medical conventional X-ray examinations F. Bouzarjomehri 1*, M.H. Dashti 2, M.H. Zare 1 1 Department of Medical

More information

National Cancer Institute

National Cancer Institute National Cancer Institute A Dosimetry Summary of CT Participants in the National Lung Screening Trial (NLST) U.S. DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health AAPM 2015 Anaheim,

More information

Estimated Radiation Dose Associated With Low-Dose Chest CT of Average-Size Participants in the National Lung Screening Trial

Estimated Radiation Dose Associated With Low-Dose Chest CT of Average-Size Participants in the National Lung Screening Trial Medical Physics and Informatics Original Research Larke et al. Estimated Radiation Dose for Low-Dose Chest CT Medical Physics and Informatics Original Research Frederick J. Larke 1 Randell L. Kruger 2

More information

A multicentric study on patient dose in multislice CT

A multicentric study on patient dose in multislice CT A multicentric study on patient dose in multislice CT A.Stratis 1, M.Molfetas 1, S.Kottou 2, A.Louizi 2 1. Medical Physics department, Evangelismos General hospital of Athens, Athens, Greece 2. Medical

More information

ICRP Symposium on the International System of Radiological Protection

ICRP Symposium on the International System of Radiological Protection ICRP Symposium on the International System of Radiological Protection October 24-26, 2011 Bethesda, MD, USA M. Balonov, ICRP Committee 2, IRH, Russia P. Shrimpton, HPA, UK To be used just for regulatory

More information

Austin Radiological Association Ga-68 NETSPOT (Ga-68 dotatate)

Austin Radiological Association Ga-68 NETSPOT (Ga-68 dotatate) Austin Radiological Association Ga-68 NETSPOT (Ga-68 dotatate) Overview Ga-68 dotatate binds to somatostatin receptors, with highest affinity for subtype 2 receptors (sstr2). It binds to cells that express

More information

Calculation of Normalised Organ and Effective Doses to Adult Reference Computational Phantoms from Contemporary Computed Tomography Scanners

Calculation of Normalised Organ and Effective Doses to Adult Reference Computational Phantoms from Contemporary Computed Tomography Scanners Progress in NUCLEAR SCIENCE and TECHNOLOGY, Vol. 2, pp.165-171 (2011) ARTICLE Calculation of Normalised Organ and Effective Doses to Adult Reference Computational Phantoms from Contemporary Computed Tomography

More information

Application of dose-area product compared with three other dosimetric quantities used to estimate patient effective dose in diagnostic radiology

Application of dose-area product compared with three other dosimetric quantities used to estimate patient effective dose in diagnostic radiology Iran. J. Radiat. Res., 2006; 4 (1): 21-27 Application of dose-area product compared with three other dosimetric quantities used to estimate patient effective dose in diagnostic radiology M.T. Bahreyni

More information

Austin Radiological Association Nuclear Medicine Procedure PET SODIUM FLUORIDE BONE SCAN (F-18 NaF)

Austin Radiological Association Nuclear Medicine Procedure PET SODIUM FLUORIDE BONE SCAN (F-18 NaF) Austin Radiological Association Nuclear Medicine Procedure PET SODIUM FLUORIDE BONE SCAN (F-18 NaF) Overview Indication Sodium Fluoride F18 injection is a radioactive diagnostic agent for positron emission

More information

Comparison of organ doses estimations in radiology with PCXMC application based on MIRD phantoms and CALDose-X application based on voxel phantoms

Comparison of organ doses estimations in radiology with PCXMC application based on MIRD phantoms and CALDose-X application based on voxel phantoms Comparison of organ doses estimations in radiology with PCXMC application based on MIRD phantoms and CALDose-X application based on voxel phantoms G. Gialousis 1, Z. Pappouli 2, A. Dimitriadis 2, E. Karavassilis

More information

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine ESTABLISHING DRLs in PEDIATRIC CT Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine CT Dose Indices CTDI INTRODUCTION CTDI 100, CTDI w, CTDI vol

More information

Entrance surface dose measurements for routine X-ray examinations in Chaharmahal and Bakhtiari hospitals

Entrance surface dose measurements for routine X-ray examinations in Chaharmahal and Bakhtiari hospitals Iran. J. Radiat. Res., 2006; 4 (1): 29-33 Entrance surface dose measurements for routine X-ray examinations in Chaharmahal and Bakhtiari hospitals D. Shahbazi-Gahrouei * Department of Medical Physics and

More information

Managing Patient Dose in Computed Tomography (CT)

Managing Patient Dose in Computed Tomography (CT) Managing Patient Dose in Computed Tomography (CT) International Commission on Radiological Protection Information abstracted from ICRP Publication 87 Available at www.icrp.org Task Group: M.M. Rehani,

More information

Assessment of Patient Dose from CT Examinations in Khorasan, Iran

Assessment of Patient Dose from CT Examinations in Khorasan, Iran Iranian Journal of Medical Physics Vol. 9, No. 4, Autumn 2012, 233-238 Received: July 18, 2012; Accepted: November 17, 2012 Original Article Assessment of Patient Dose from CT Examinations in Khorasan,

More information

Assessment of radiation risk to pediatric patients undergoing conventional X-ray examinations

Assessment of radiation risk to pediatric patients undergoing conventional X-ray examinations Radioprotection 50(1), 19-25 (2015) c EDP Sciences 2015 DOI: 10.1051/radiopro/2014023 Available online at: www.radioprotection.org Article Assessment of radiation risk to pediatric patients undergoing

More information

CT Radiation Risks and Dose Reduction

CT Radiation Risks and Dose Reduction CT Radiation Risks and Dose Reduction Walter L. Robinson, M.S. D.A.B.S.N.M., D.A.B.M.P., D.A.B.R. Consultant Certified Medical Radiation Health & Diagnostic Imaging Physicist Medical Radiation and Children

More information

A Standardised Approach to Optimisation

A Standardised Approach to Optimisation The Radiographer vol. 51: 105-110 A Standardised Approach to Optimisation Helen M. Warren-Forward 1 & Ronald Beckhaus 2 ABSTRACT Purpose: Optimisation of radiographic images is said to have been obtained

More information

3 rd International Symposium on the System of Radiological Protection Seoul, October John Harrison

3 rd International Symposium on the System of Radiological Protection Seoul, October John Harrison 3 rd International Symposium on the System of Radiological Protection Seoul, October 2015 John Harrison UK Task Group 79 : Use of Effective Dose as a Risk-related Radiological Protection Quantity John

More information

Radiation related cancer risk & benefit/risk assessment for screening procedures

Radiation related cancer risk & benefit/risk assessment for screening procedures WHO Workshop on Justification of CT for IHA 15-17 Oct 2014 Radiation related cancer risk & benefit/risk assessment for screening procedures Elke A. Nekolla BfS Federal Office for Radiation Protection Radiation

More information

Estimating the Radiation-Induced Cancer Risks in Pediatric Computed Tomography

Estimating the Radiation-Induced Cancer Risks in Pediatric Computed Tomography Iranian Journal of Medical Physics Vol. 13, No. 4, December 2016, 218-227 Received: August 20, 2016; Accepted: November 04, 2016 Original Article Estimating the Radiation-Induced Cancer Risks in Pediatric

More information

GUIDELINES ON IONISING RADIATION DOSE LIMITS AND ANNUAL LIMITS ON INTAKE OF RADIOACTIVE MATERIAL

GUIDELINES ON IONISING RADIATION DOSE LIMITS AND ANNUAL LIMITS ON INTAKE OF RADIOACTIVE MATERIAL RADIATION PROTECTION AUTHORITY OF ZIMBABWE (RPAZ) RADIATION PROTECTION ACT [CHAPTER 15:15] GUIDELINES ON IONISING RADIATION DOSE LIMITS AND ANNUAL LIMITS ON INTAKE OF RADIOACTIVE MATERIAL Compiled by Radiation

More information

RPR 48B. APPLICATION TO USE DIAGNOSTIC EXTERNAL RADIATION IN HUMAN RESEARCH STUDIES

RPR 48B. APPLICATION TO USE DIAGNOSTIC EXTERNAL RADIATION IN HUMAN RESEARCH STUDIES RPR 48B. APPLICATION TO USE DIAGNOSTIC EXTERNAL RADIATION IN HUMAN RESEARCH STUDIES HUMAN USE SUBCOMMITTEE OF THE RADIATION SAFETY COMMITTEE UNIVERSITY OF UTAH HEALTH SCIENCES CENTER SALT LAKE CITY, UT

More information

AAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction

AAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction AAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction Parham Alaei, Ph.D. Department of Radiation Oncology University of Minnesota NCCAAPM Fall

More information

Impact of ICRP-89 Based Models on Dose Estimates for Radiopharmaceuticals and CT Exams. Stabin MG, Kost SD, Clark JH, Pickens DR, Price RR, Carver DE

Impact of ICRP-89 Based Models on Dose Estimates for Radiopharmaceuticals and CT Exams. Stabin MG, Kost SD, Clark JH, Pickens DR, Price RR, Carver DE Impact of ICRP-89 Based Models on Dose Estimates for Radiopharmaceuticals and CT Exams Stabin MG, Kost SD, Clark JH, Pickens DR, Price RR, Carver DE Vanderbilt University, Nashville, TN, USA Abstract New

More information

CURRENT CT DOSE METRICS: MAKING CTDI SIZE-SPECIFIC

CURRENT CT DOSE METRICS: MAKING CTDI SIZE-SPECIFIC CURRENT CT DOSE METRICS: MAKING CTDI SIZE-SPECIFIC Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine Acknowledgments John Boone, PhD Michael McNitt-Grey,

More information

Introduction and Background

Introduction and Background CT Lung Cancer Screening and the Medical Physicist: Background, Findings and Participant Dosimetry Summary of the National Lung Screening Trial (NLST) Randell Kruger, PhD, DABR Medical Physics Section

More information

Cumulative radiation CT dose in young traumatic patients: a single centre 5 years retrospective review

Cumulative radiation CT dose in young traumatic patients: a single centre 5 years retrospective review Cumulative radiation CT dose in young traumatic patients: a single centre 5 years retrospective review Poster No.: C-1604 Congress: ECR 2014 Type: Scientific Exhibit Authors: S. Salerno, C. Geraci, E.

More information

Patient / Organ Dose in CT

Patient / Organ Dose in CT Patient / Organ Dose in CT Patient specific and organ dose estimation H.D. Nagel Dr. HD Nagel, Science & Technology for Radiology Buchholz / Germany www.sascrad.com 1 Topics CTDI & patient dose SSDE Organ

More information

JHM-IRB Guidelines for Radiation Statements

JHM-IRB Guidelines for Radiation Statements JHM-IRB Guidelines for Radiation Statements When a participant in a research study is subjected to ionizing radiation exposure (other than that which is incidental for the standard medical management of

More information

Prof. Dr. Doğan BOR Ankara University Institute of Nuclear Science

Prof. Dr. Doğan BOR Ankara University Institute of Nuclear Science PATIENT DOSIMETRY IN DIAGNOSTIC RADIOLOGY MODALITIES Prof. Dr. Doğan BOR Ankara University Institute of Nuclear Science Ankara University Institute of Nuclear Science USE OF RADIATION! INCREASING? Natural

More information

Cone Beam CT Protocol Optimisation for Prostate Imaging with the Varian Radiotherapy OBI imaging system. Dr Craig Moore & Dr Tim Wood

Cone Beam CT Protocol Optimisation for Prostate Imaging with the Varian Radiotherapy OBI imaging system. Dr Craig Moore & Dr Tim Wood Cone Beam CT Protocol Optimisation for Prostate Imaging with the Varian Radiotherapy OBI imaging system Dr Craig Moore & Dr Tim Wood Background With the increasing use of CBCT imaging alongside complex

More information

Patient effective dose evaluation for chest X-ray examination in three digital radiography centers

Patient effective dose evaluation for chest X-ray examination in three digital radiography centers Patient effective dose evaluation for chest X-ray examination in three digital radiography centers R. Paydar 1,3*, A. Takavar 1, M.R. Kardan 2,3, A. Babakhani 3,4, M.R. Deevband 3, S. Saber 5 1Medical

More information

Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode

Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode S.M. Ghavami 1, A. Mesbahi 2,3*, I. Pesianian 1 Iran. J. Radiat. Res., 2012; 10(2): 89-94

More information

FAX, A FEMALE ADULT VOXEL PHANTOM FOR RADIATION PROTECTION DOSIMETRY

FAX, A FEMALE ADULT VOXEL PHANTOM FOR RADIATION PROTECTION DOSIMETRY EFFECTIVE DOSE RATIOS FOR THE TOMOGRAPHIC MAX AND FAX PHANTOMS ******************************************************** EFFECTIVE DOSE RATIOS FOR TOMOGRAPHIC AND STYLIZED MODELS FROM > EXTERNAL EXPOSURE

More information

Doses from CT examinations to children suffering from hydrocephalus

Doses from CT examinations to children suffering from hydrocephalus Doses from CT examinations to children suffering from hydrocephalus E. G. Friberg 1, L. J. Holmedal 2, I. Børretzen 1, K. Rosendahl 3 and H. M. Olerud 1 1 Norwegian Radiation Protection Authority, P.O.

More information

Dosimetric Consideration in Diagnostic Radiology

Dosimetric Consideration in Diagnostic Radiology Dosimetric Consideration in Diagnostic Radiology Prof. Ng Kwan-Hoong Department of Biomedical Imaging University of Malaya ngkh@um.edu.my Radiation Dosimetry Workshop, 28-29 March 2014 2 Why do we measure

More information

Measurement of Entrance Skin Dose and Calculation of Effective Dose for Common Diagnostic X-Ray Examinations in Kashan, Iran

Measurement of Entrance Skin Dose and Calculation of Effective Dose for Common Diagnostic X-Ray Examinations in Kashan, Iran Global Journal of Health Science; Vol. 7, No. 5; 2015 ISSN 1916-9736 E-ISSN 1916-9744 Published by Canadian Center of Science and Education Measurement of Entrance Skin Dose and Calculation of Effective

More information

What Have We Learned from Children? Donald P. Frush, MD

What Have We Learned from Children? Donald P. Frush, MD What Have We Learned from Children? Donald P. Frush, MD Medical Radiation and Children: Accomplishments We can lower doses (read noisier exams) We should lower doses Multiphase exams should be justified

More information

National collection of local diagnostic reference levels in Norway and their role in optimization of X-ray examinations

National collection of local diagnostic reference levels in Norway and their role in optimization of X-ray examinations National collection of local diagnostic reference levels in Norway and their role in optimization of X-ray examinations Eva Godske Friberg *, Anders Widmark and Ingrid Helen Ryste Hauge Norwegian Radiation

More information

Radiation Doses in Radiology: Influence of Standards and Regulations

Radiation Doses in Radiology: Influence of Standards and Regulations Radiation Doses in Radiology: Influence of Standards and Regulations Beebe Symposium National Academy of Sciences December 9, 2009 Washington D.C. Orhan H Suleiman MS PhD, FAAPM Senior Science Policy Adviser

More information

Estimating Risks from CT Scans - in the Context of CT Scan Benefits

Estimating Risks from CT Scans - in the Context of CT Scan Benefits Estimating Risks from CT Scans - in the Context of CT Scan Benefits David J. Brenner Center for Radiological Research Columbia University Medical Center djb3@cumc.columbia.edu There is no question that

More information

Estimation of the number of total and pediatric CT procedures based. on a nationwide survey in Japan

Estimation of the number of total and pediatric CT procedures based. on a nationwide survey in Japan Estimation of the number of total and pediatric CT procedures based on a nationwide survey in Japan Koji Ono 1, Nobuhiko Ban 2, Kai Michiaki 1. 1 Oita University of Nursing and Health Sciences 2944-9,

More information

Estimating Patient Radiation Dose from Computed Tomography

Estimating Patient Radiation Dose from Computed Tomography Estimating Patient Radiation Dose from Computed Tomography C. Cagnon, J. DeMarco, E. Angel, M. McNitt-Gray UCLA David Geffen School of Medicine 1 Patient Dose from CT Advances in Technology... Helical

More information

Impact of ICRP-89 Based Models on Dose Estimates for Radiopharmaceuticals and CT Exams

Impact of ICRP-89 Based Models on Dose Estimates for Radiopharmaceuticals and CT Exams Impact of ICRP-89 Based Models on Dose Estimates for Radiopharmaceuticals and CT Exams Stabin MG, Kost SD, Clark JH, Pickens DR, Price RR, Carver DE Vanderbilt University Nashville, TN, USA 13th International

More information

Ask EuroSafe Imaging Tips & Tricks. CT Working Group

Ask EuroSafe Imaging Tips & Tricks. CT Working Group Ask EuroSafe Imaging Tips & Tricks CT Working Group Organ Based Tube Current Modulation to Reduce Radiation Dose to Superficial Radiosensitive Organs Eileen Kelly (Galway University Hospitals, IE) Matthias

More information

Quality Control and Patient Dosimetry on line for Computed Tomography

Quality Control and Patient Dosimetry on line for Computed Tomography Quality Control and Patient Dosimetry on line for Computed Tomography Jose I. Ten 1,2, Eliseo Vano 2,3, Jose M. Fernandez-Soto 2,3, Roberto Sanchez 3, Juan Arrazola 1,2 1 Diagnostic Radiology Service and

More information

Recent Progress in Radiation Dosimetry for Epidemiology and Radiological Protection. John Harrison ICRP Committee 2

Recent Progress in Radiation Dosimetry for Epidemiology and Radiological Protection. John Harrison ICRP Committee 2 Recent Progress in Radiation Dosimetry for Epidemiology and Radiological Protection John Harrison ICRP Committee 2 Joint ICRP-RERF-JHPS Workshop: Tokyo, December 2017 Task Group 79 : Use of Effective Dose

More information

Thoracic examinations with 16, 64, 128 and 256 slices CT: comparison of exposure doses measured with an anthropomorphic phantom and TLD dosimeters

Thoracic examinations with 16, 64, 128 and 256 slices CT: comparison of exposure doses measured with an anthropomorphic phantom and TLD dosimeters Thoracic examinations with 16, 64, 128 and 256 slices CT: comparison of exposure doses measured with an anthropomorphic phantom and TLD dosimeters Poster No.: C-2584 Congress: ECR 2015 Type: Scientific

More information

Comparison of adsorbed skin dose received by patients in cone beam computed tomography, spiral and conventional computed tomography scanninng

Comparison of adsorbed skin dose received by patients in cone beam computed tomography, spiral and conventional computed tomography scanninng (1390 3 24 ) 3 3 2 - - - 1-1 -2-3 Comparison of adsorbed skin dose received by patients in cone beam computed tomography, spiral and conventional computed tomography scanninng Ghazi Khanlou Sani K 1, Eskandarlou

More information

Estimated cumulative radiation dose from PET/CT in children with malignancies: a 5-year retrospective review

Estimated cumulative radiation dose from PET/CT in children with malignancies: a 5-year retrospective review Pediatr Radiol (1) :681 686 DOI 1.17/s247-9-1434-z ORIGINAL ARTICLE Estimated cumulative radiation dose from PET/CT in children with malignancies: a 5-year retrospective review Soni C. Chawla & Noah Federman

More information

Measurement of Kidneys Dose in Three Hospitals during Chest and Abdomen Radiographic Examinations

Measurement of Kidneys Dose in Three Hospitals during Chest and Abdomen Radiographic Examinations Measurement of Kidneys Dose in Three Hospitals during Chest and Abdomen Radiographic Examinations Nadia Alatta 1, Abdelrahaman Elnour 2, Ikhlas Abdelaziz 3, Tugua Tageldeen 4, Duha Abdu 5, Asma Elamin

More information

FDG-18 PET/CT - radiation dose and dose-reduction strategy

FDG-18 PET/CT - radiation dose and dose-reduction strategy FDG-18 PET/CT - radiation dose and dose-reduction strategy Poster No.: C-1856 Congress: ECR 2014 Type: Authors: Keywords: DOI: Scientific Exhibit P. Nicholson, S. McSweeney, K. O'Regan; Cork/IE Radiation

More information

Fetal Dose Calculations and Impact on Patient Care

Fetal Dose Calculations and Impact on Patient Care Fetal Dose Calculations and Impact on Patient Care Matt Hough, MS, DABR, DABMP Florida Hospital Diagnostic Medical Physics and Radiation Safety Resource ACR-SPR Practice Parameter for Imaging Pregnant

More information

Tracking Doses in the Pediatric Population

Tracking Doses in the Pediatric Population Tracking Doses in the Pediatric Population Frederic H. Fahey DSc Boston Children s Hospital Harvard Medical School frederic.fahey@childrens.harvard.edu Disclosures Sadly, none that pay me any money! SNMMI

More information

A Real-Time Monte Carlo System for Internal Dose Evaluation Using an Anthropomorphic Phantom with Different Shapes of Tumors Inserted

A Real-Time Monte Carlo System for Internal Dose Evaluation Using an Anthropomorphic Phantom with Different Shapes of Tumors Inserted A Real-Time Monte Carlo System for Internal Dose Evaluation Using an Anthropomorphic Phantom with Different Shapes of Tumors Inserted J. Wu, S. J. Chang, B. J. Chang, I. J. Chen, J. H. Chiu Health Physics

More information

Organ Dose Variability with Gender, Age and BMI

Organ Dose Variability with Gender, Age and BMI Organ Dose Variability with Gender, Age and BMI Dr Ted Lazo CRPPH Scientific Secretariat Article 31 Meeting, 17 May 2017, Luxembourg Background The ICRP system uses a generalised, gender and age averaged

More information

CT Optimisation for Paediatric SPECT/CT Examinations. Sarah Bell

CT Optimisation for Paediatric SPECT/CT Examinations. Sarah Bell CT Optimisation for Paediatric SPECT/CT Examinations Sarah Bell Sarah.bell14@nhs.net Outline 1. Introduction 2. Aims and Objectives 3. Methods 4. Results 5. Discussion 6. Conclusions 7. References Introduction

More information

Privileged Communication

Privileged Communication Estimation of the Radiation Dose from Thoracic CT Scans in a Cystic Fibrosis Population Journal: Manuscript ID: Manuscript Type: Date Submitted by the Author: -0-0.R Manuscript 0-Jun-0 Complete List of

More information

Radiation Dose Reduction Strategies in Coronary CT Angiography

Radiation Dose Reduction Strategies in Coronary CT Angiography Radiation Dose Reduction Strategies in Coronary CT Angiography Noor Diyana Osman, PhD noordiyana@usm.my Contents: Introduction Radiation dosimetry in CT Radiation risk associated with coronary CT angiography

More information

2005 RECOMMENDATIONS OF ICRP

2005 RECOMMENDATIONS OF ICRP IRPA 11 11 th International Congress of the International Radiation Protection Association 23 28 May 2004, Madrid, Spain 2005 RECOMMENDATIONS OF ICRP ROGER H CLARKE CHAIRMAN FEATURES OF RECOMMENDATIONS

More information

RADIATION DOSES TO PATIENTS UNDERGOING BARIUM MEAL AND BARIUM ENEMA EXAMINATIONS

RADIATION DOSES TO PATIENTS UNDERGOING BARIUM MEAL AND BARIUM ENEMA EXAMINATIONS Radiation Protection Dosimetry (2004), Vol. 109, No. 3, pp. 243±247 DOI: 10.1093/rpd/nch047 RADIATION DOSES TO PATIENTS UNDERGOING BARIUM MEAL AND BARIUM ENEMA EXAMINATIONS M. G. Delichas 1, K. Hatziioannou

More information

Background Radiation in U.S. ~ msv/yr msv/yr ~0.02 ~0.02 msv msv/day /day (~2 m rem/day) mrem/day) NCRP 4

Background Radiation in U.S. ~ msv/yr msv/yr ~0.02 ~0.02 msv msv/day /day (~2 m rem/day) mrem/day) NCRP 4 Patient Safety Concerns in Diagnostic Radiology? Lawrence T. Dauer, PhD, CHP Assistant Attending Health Physicist Department of Medical Physics RAMPS/GNYCHPS Spring Symposium April 30, 2010 Benefits?

More information

CT Radiation Dosimetry Study Using Monte Carlo Simulation and. Computational Anthropomorphic Phantoms

CT Radiation Dosimetry Study Using Monte Carlo Simulation and. Computational Anthropomorphic Phantoms CT Radiation Dosimetry Study Using Monte Carlo Simulation and Computational Anthropomorphic Phantoms by Yakun Zhang Graduate Program in Medical Physics Duke University Date: Approved: Ehsan Samei, Supervisor

More information

Water Any Inulin IV Normal renal function Inulin IV Abnormal renal function Glucose IV Normal Carfentanil IV 17.

Water Any Inulin IV Normal renal function Inulin IV Abnormal renal function Glucose IV Normal Carfentanil IV 17. Table 1: Effective Dose Equivalent (HE) values for common procedures involving the use of radiopharmaceuticals. Listings (last column) are averaged over both sexes, and are computed for adult subjects.

More information

Regional diagnostic reference levels and collective effective doses from CT scanners in India

Regional diagnostic reference levels and collective effective doses from CT scanners in India Regional diagnostic reference levels and collective effective doses from CT scanners in India Roshan S Livingstone and Paul M Dinakaran Department of Radiology Christian Medical College, Vellore, S India

More information

Dosimetry of recently introduced CBCT Units for Oral and Maxillofacial Radiology

Dosimetry of recently introduced CBCT Units for Oral and Maxillofacial Radiology Dosimetry of recently introduced CBCT Units for Oral and Maxillofacial Radiology John B Ludlow, Laura E Davies-Ludlow, André Mol University of North Carolina, Chapel Hill, NC Background CBCT is seeing

More information

Assessing the standard dose to standard patients for x-ray investigations

Assessing the standard dose to standard patients for x-ray investigations Assessing the standard dose to standard patients for x-ray investigations A. Almén and W. Leitz Swedish Radiation Protection Authority, SE-171 16 Stockholm, Sweden E-mail: anja.almen@ssi.se Abstract. The

More information

Estimation of Organ and Effective Doses for Neonate and Infant Diagnostic Cardiac Catheterizations

Estimation of Organ and Effective Doses for Neonate and Infant Diagnostic Cardiac Catheterizations Medical Physics and Informatics Original Research Kawasaki et al. Dose Estimates for Neonate and Infant Diagnostic Cardiac Catheterization Medical Physics and Informatics Original Research Toshio Kawasaki

More information

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols Personalization of Pediatric Imaging in Terms of Needed Indication-Based Quality Per Dose Acknowledgments Duke University Medical Center Ehsan Samei, PhD Donald Frush, MD Xiang Li PhD DABR Cleveland Clinic

More information

EFFECTIVENESS OF PROTECTIVE PATIENT EQUIPMENT FOR CT: AN ANTHROPOMORPHIC PHANTOM STUDY Barbara Ott 1, *, Anja Stüssi 2 and Roberto Mini 1

EFFECTIVENESS OF PROTECTIVE PATIENT EQUIPMENT FOR CT: AN ANTHROPOMORPHIC PHANTOM STUDY Barbara Ott 1, *, Anja Stüssi 2 and Roberto Mini 1 Radiation Protection Dosimetry Advance Access published September 8, 2010 Radiation Protection Dosimetry (2010), pp. 1 9 doi:10.1093/rpd/ncq214 EFFECTIVENESS OF PROTECTIVE PATIENT EQUIPMENT FOR CT: AN

More information

Patient dose assessment of CT perfusion scanning at the RSCH

Patient dose assessment of CT perfusion scanning at the RSCH Patient dose assessment of CT perfusion scanning at the RSCH Lesley Leavesley, Emma Whitehead, Matthew Pryor, Debbie Peet Regional Radiation Protection Service Royal Surrey County Hospital, Guildford Overview

More information

Radiation Protection Program Update: The Details. July 2010

Radiation Protection Program Update: The Details. July 2010 Radiation Protection Program Update: The Details July 2010 Update Topics 2 Changes mandated by Title 10, Code of Federal Regulations, Part 835, Occupational Radiation Protection (10 CFR 835) How changes

More information

United Nations Scientific Committee on the Effects of Atomic Radiation

United Nations Scientific Committee on the Effects of Atomic Radiation United Nations Scientific Committee on the Effects of Atomic Radiation ATTACHMENT D-1 ESTIMATION OF THE POSSIBLE CONTRIBUTION OF INTAKES OF SHORT-LIVED RADIONUCLIDES TO EFFECTIVE DOSE AND ABSORBED DOSES

More information

The activity. Suggested Answers

The activity. Suggested Answers Teacher notes Introduction This activity encourages students to consider the principles of radiation protection and how they might apply in the nuclear industry and in medicine. They discuss and answer

More information

Radiation dose optimization in CT planning of corrective scoliosis surgery. A phantom study.

Radiation dose optimization in CT planning of corrective scoliosis surgery. A phantom study. Radiation dose optimization in CT planning of corrective scoliosis surgery. A phantom study. Abul-Kasim, Kasim; Gunnarsson, Mikael; Maly, Pavel; Ohlin, Acke; Maly Sundgren, Pia Published in: The Neuroradiology

More information

CT Dose Reduction in Pediatric Patients

CT Dose Reduction in Pediatric Patients CT Dose Reduction in Pediatric Patients By Kelly Firestine, RT(R)(CT)(M) Executive Summary CT is an incredibly valuable imaging tool, but there are unique concerns with pediatric patients, including the

More information

Patient doses in radiographic examinations in Western and Eastern Azerbyjan provinces of Iran

Patient doses in radiographic examinations in Western and Eastern Azerbyjan provinces of Iran Patient doses in radiographic examinations in Western and Eastern Azerbyjan provinces of Iran Soraya Emamgholizadeh Minaei 1, Fariba Firouzi 1 2, 3,*, Hamid Reza Khosravi 1 Department of radiology, Shahid

More information

DETERMINATION OF ENTRANCE SKIN DOSE FROM DIAGNOSTIC X-RAY OF HUMAN CHEST AT FEDERAL MEDICAL CENTRE KEFFI, NIGERIA

DETERMINATION OF ENTRANCE SKIN DOSE FROM DIAGNOSTIC X-RAY OF HUMAN CHEST AT FEDERAL MEDICAL CENTRE KEFFI, NIGERIA DETERMINATION OF ENTRANCE SKIN DOSE FROM DIAGNOSTIC X-RAY OF HUMAN CHEST AT FEDERAL MEDICAL CENTRE KEFFI, NIGERIA Full Length Research Article 1 Ibrahim, U, 3 Daniel, I.H., 3 Ayaninola, O., 4 Ibrahim,

More information

Patient Dose Estimates. from CT Examinations. Patient Dose Estimates

Patient Dose Estimates. from CT Examinations. Patient Dose Estimates Patient Dose Estimates from CT Examinations Patient Dose Estimates from CT Examinations John M. Boone, Ph.D. Professor and Vice Chairman of Radiology Professor of Biomedical Engineering University of California,

More information

Cancer Risks from CT Scans: Now We Have Data What Next?

Cancer Risks from CT Scans: Now We Have Data What Next? Cancer Risks from CT Scans: Now We Have Data What Next? David J. Brenner, PhD, DSc Center for Radiological Research Columbia University Medical Center djb3@columbia.edu There is no question that CT has

More information

Chief Radiographer TEI Clinical Associate 2016

Chief Radiographer TEI Clinical Associate 2016 MDCT Principles i and Applications Ε ΑGADAKOS MSc Ε. ΑGADAKOS MSc Chief Radiographer TEI Clinical Associate 2016 Aim To understand d recent technological advances in MSCT and how they can be effectively

More information

Computed Tomography Dose in Paediatric Care: Simple Dose Estimation Using Dose Length Product Conversion Coefficients

Computed Tomography Dose in Paediatric Care: Simple Dose Estimation Using Dose Length Product Conversion Coefficients Original Article Computed Tomography Dose in Paediatric Care: Simple Dose Estimation Using Dose Length Product Conversion Coefficients Nor Hanani Mohd Tap, Mohamed Ariff Jaafar Sidek, Siti Farizwana Mohd

More information

Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters

Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters Original Article PROGRESS in MEDICAL PHYSICS Vol. 26, No. 2, June, 2015 http://dx.doi.org/10.14316/pmp.2015.26.2.93 Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters

More information

Dosimetric Evaluation of Multislice CT Using Anthropomorphic Head Phantom

Dosimetric Evaluation of Multislice CT Using Anthropomorphic Head Phantom Original Article Dosimetric Evaluation of Multislice CT Using Anthropomorphic Head Phantom Seyedeh Fatemeh Seyedatashi 1, Mitra Athari 1, Ahmad Bitarafan-Rajabi 2, Hadi Hasanzadeh 3, *, Mehravar Rafati

More information