Strengthening Results. Advanced Chromatography with Mass Detection
|
|
- Adrian Alexander
- 5 years ago
- Views:
Transcription
1 Strengthening Results Advanced Chromatography with Mass Detection
2 UV Detection Why Not Use UV For Everything? Identification Difficult selectivity in complex matrices Sensitivity Need sufficient molar absorptivity Method Development Peak assignments require confirmation runs Quantitation Relatively high detection limits and narrow dynamic ranges Definitive Confirmation May require confirmation analysis Structural Information Limited information 2
3 What Are Some of the Benefits to Mass Detection? UltiMate LC System MSQ Plus Mass Detector 3
4 Benefits: Reduce Matrix Background Interference Mass detectors allow analyte-specific detection within matrices Column Hypersil Gold PFP 50 x 2.1, 1.9 um Gradient H2O:ACN 0.1% FA Flow Rate 500 ul/min Injection 2 ul Analyte 10 ppm Detector nm 4
5 Benefits: Improve Limit of Quantitation Mass detectors allow analyte-specific detection within matrices Column Hypersil Gold PFP 50 x 2.1, 1.9 um Gradient H2O:ACN 0.1% FA Flow Rate 500 ul/min Injection 2 ul Analyte 10 ppm Detector ESI Positive Capillary 4.5 kv Probe 550 C Standard in Urine Water 152 m/z 152 m/z m/z m/z Filter contaminants, isolate analyte, and increase sensitivity Minimize sample preparation, simplify workflow, increase throughput 195 m/z 195 m/z 5
6 Benefit: Improve Limit of Quantitation Mass detectors allow sensitive, robust, multi-component quantitation across large linear dynamic ranges Column Hypersil Gold PFP 100 x 2.1, 1.9 um Gradient (Ternary) H2O:MeOH:ACN 0.1% Acetic Acid Flow Rate 1,000 ul/min Injection 2 ul Analyte Variable Detector ESI Positive Capillary 4.5 kv Probe 450 C 6
7 Benefit: Improve Limit of Quantitation Mass detectors allow sensitive, robust, multi-component quantitation across large linear dynamic ranges Column Hypersil Gold PFP 100 x 2.1, 1.9 um Gradient (Ternary) H2O:MeOH:ACN 0.1% Acetic Acid Flow Rate 1,000 ul/min Injection 2 ul Analyte Variable Detector ESI Positive Capillary 4.5 kv Probe 450 C Improve limits of detection and quantitation for multi-component analyses 7
8 Benefit: No Chromaphore required Mass detectors ionize and detect analytes that do not exhibit strong UV absorbencies Column Hypersil Gold PFP 100 x 2.1, 1.9 um Gradient H2O:MeOH Ammonium Formate Flow Rate 500 ul/min Injection 2 ul Analyte Triacetone triperoxide (TATP) Detector APCI Positive Corona 30 ua Probe 350 C TATP Common for terrorist activities 348 m/z No significant absorption No florescence activity Highly unstable TATP (222 m/z) + Fragment (108 m/z) + Ammonium (18 m/z) Heat, friction, shock, and UV light TATP Overcome limitations associated with conventional LC detection 8
9 Benefit: Detect Inorganic Analytes Mass detectors allow inorganic analysis concurrent with organic analysis Column Hypercarb 100 x 2.1, 5 um Gradient H2O:MeOH 1% FA Flow Rate 300 ul/min Injection 5 ul Analyte Gunpowder Extraction ~ 50 ug/ml Detector ESI Positive/Negative Capillary 3.5 kv Probe 550 C Cations Anions Time (min) Increase throughput by using an all-in-one detector 9
10 Benefit: Confirm Identification Mass detectors allows confident and efficient identification of analyte peaks Method 1 Column Hypersil Gold PFP 100 x 2.1, 1.9 um Gradient Caffeine Cocaine H2O:ACN 0.1% Acetic Acid Flow Rate Method 2 1,000 ul/min Injection Caffeine Cocaine 2 ul Analyte 500 ppb Detector ESI Positive Capillary 3.5 kv Probe 450 C 195 m/z Caffeine Cocaine 304 m/z Quickly identify peaks after changing columns, gradients, or flow rates 10
11 Benefit: Additional Information on Impurities Mass detectors strengthen purity analysis by generating impurity spectra Column Hypersil Gold 100 x 2.1, 1.9 um Isocratic H2O:MeOH AU Flow Rate 800 ul/min Injection 5 ul Analyte Simvastatin Detector (UV) 254 nm Detector (Mass) ESI Positive/Negative Capillary 3.0 kv Probe 550 C Degradant m/z 4 Statin Minutes Statin Degradation Lactone Hydroxy Acid 8 9 Identify the mass, structure, and source of impurities 11
12 Benefit: Definitive Confirmation Mass detectors allow systematic and reproducible fragmentation of analyte for multiple orders of confirmation Column Hypersil Gold 100 x 2.1, 1.9 um Isocratic H2O:MeOH Flow Rate 800 ul/min Injection 5 ul Analyte Illicit Drugs Detector ESI Positive Capillary 3.5 kv Probe 550 C Relative Abundance Psilocin Seized Evidence Increase Cone Voltage Increase Cone Voltage 115 m/z Loss of OH Loss of C 2 H 4 m/z Loss of HN(CH 3 ) 2 m/z 132 m/z 160 m/z 205 m/z Psilocin Time (min) m/z Effectuate compound-specific fragmentation and match to theoretical behavior 12
13 Benefit: Library Search Mass detectors allow matching of spectra against user-generated libraries Column Hypersil Gold PFP 100 x 2.1, 1.9 um Gradient H2O:MeOH Ammonium Formate Flow Rate 500 ul/min Injection 2 ul Analyte Soil Extraction LOD 0.2 ug/kg Detector APCI Negative Corona 30 ua Probe 350 C RT 7.18 min Trinitrotoluene 98.19% Probability Unknown Soil Sample Library Data Confidently screen samples for target analytes using library matching 13
14 Mass Detection Strengthen Chromatography Easier Identification Ionize analyte with low molar absorptivity Create positive and negative ions simultaneously Greater Sensitivity Enhance selectivity Filter contaminants Faster Method Development Simplify peak assignment Enhanced Quantitation Isolate analytes More Definitive Confirmation Match against spectral libraries Induce compound-specific fragmentation Structural Information Identify impurities Increase sensitivity Improve quantitation UltiMate LC System MSQ Plus Mass Detector 14
15 How Does Mass Detection Work? UltiMate LC System MSQ Plus Mass Detector 15
16 What is a Mass Detection? Mass detection is the measurement of the mass-to-charge ratio of individual molecules that have been converted to gas phase ions. Mass Spectrum: A plot of mass to charge (m/z) vs. relative or absolute intensity. Light Filter Mass Filter 16
17 MSQ Plus Mass Detector Single Quadrupole Strengthen chromatography with enhanced mass detection Mass confirmation Robust quantitation Structural elucidation Positive identification FastLoc Probe Entrance Cone Exit Cone Ion Bright Detector Cone Wash Transfer Lens Quadrupole Analyzer Analyte from LC Column Vacuum Signal to Data System 17
18 MSQ Plus Mass Detector: Advanced LC Detection Expanded Application Versatility Extended Da mass range FastLoc TM ESI and APCI Probes Maximum flow rate 2 ml/min for both ESI and APCI Minimized Operation Costs Patented titanium entrance cone Increased Sensitivity Scan speeds up to 12,000 amu/sec Patented Cone Wash technology 18
19 MSQ Plus Mass Detector: Advanced LC Detection Maximized Sample Throughput Patented M-path Source Wipe clean surfaces for easy maintenance Greater User Confidence Automatic tune and calibration Improved Quantitative Ability Source CID (Collision Induced Dissociation) for ion fragmentation Simultaneous quantitative and qualitative determinations by combining Full Scan and SIM. Multiple scan modes with one injection (+/-, FS, SIM, overlapping segments) 19
20 Example Applications UltiMate LC System MSQ Plus Mass Detector 20
21 A Single Ternary Method for 14 Drugs Fourteen drugs baseline separated in twelve minutes by employing UHPLC/MS with a ternary solvent gradient. Identified Quantified Hypersil GOLD PFP 1.9um, 100 x 2.1 mm; ternary gradient of water, acetonitrile, and methanol with acetic acid at 1 ml/min; 1 ul injection; ESI Positive 21
22 22 A Single Ternary Method for 14 Drugs
23 Hallucinogenic Mushrooms in Chocolate Easily separate psilocybin and psilocin using UHPLC/MS, avoiding detection difficulties such as low concentration, thermal lability, and matrix interference that are typical with other techniques Psilocybin Psilocin Standard Psilocybin (RT: 0.65min) Relative Abundance Psilocybin Psilocin Chocolate Relative Abundance Psilocin (RT: 2.26min) Time (min) m/z Identified Confirmed Hypersil GOLD PFP 1.9um, 100 x 2.1 mm; ternary gradient of water, acetonitrile, and methanol with acetic acid at 1 ml/min; 2 ul injection; ESI Positive 23
24 Confirmation of Psilocin Definitively confirm the presence of illicit drugs using UHPLC/MS, by creating and searching spectral libraries for fragmentation patterns produced through in-source collision induced dissociation Relative Abundance Psilocin (low cone voltage) m/z Relative Abundance In-Source CID (medium cone voltage) Relative Abundance In-Source CID (high cone voltage) m/z Confirmed Rodriguez Cruz, Sandra E., Analysis and Characterization of Psilocybin and Psilocin Using Liquid Chromatography Electrospray Ionization Mass Spectrometry (LC ESI MS) with Collision-Induced-Dissociation (CID) and Source-Induced-Dissociation (SID), Microgram Journal, Volume 3 Numbers 3-4 (2005) m/z Confirmed 24
25 LSD in Candy Hearts Positively identify LSD within a complex matrix using UHPLC/MS, requiring no downtime for instrument bake-out and clean-up Relative Abundance Standard Candy Heart LSD LSD Relative Abundance LSD (RT: 4.49min) Time (min) m/z Identified Confirmed Hypersil GOLD PFP 1.9um, 100 x 2.1 mm; ternary gradient of water, acetonitrile, and methanol with acetic acid at 1 ml/min; 2 ul injection, ESI Positive 25
26 Marijuana in Brownies Efficiently separate and detect THC, cannabinol, and cannabidiol using UHPLC/MS, consuming only milligram amounts of evidence Standard Cannabidiol THC Cannabinol Cannabidiol (RT: 4.1min) Relative Abundance Brownie THC Relative Abundance THC (RT: 5.1min) Cannabinol (RT: 5.4min) Time (min) m/z Identified Confirmed Hypersil GOLD PFP 1.9um, 100 x 2.1 mm; ternary gradient of water, acetonitrile, and methanol with acetic acid at 1 ml/min; 2 ul injection; ESI Positive 26
27 Pseudoephedrine in Tablets Quantify ephedrine, pseudoephedrine, methamphetamine, amphetamine, and 3,4-MDMA using UHPLC/MS; and, elucidate the current manufacturing pathways of clandestine chemistry Relative Abundance Standard Tablet Ephedrine Pseudoephedrine Pseudoephedrine Amphetamine Methamphetamine 3,4-MDMA Area (10 4 ) Pseudoephedrine (RT: 2.60min) R 2 = LOQ = 1.2 ppb LOD = 0.4 ppb Time (min) Concentration (ppb) Identified Quantified Hypersil GOLD PFP 1.9um, 100 x 2.1 mm; binary gradient of water and acetonitrile with acetic acid at 1 ml/min; 1 ul injection; ESI Positive 27
28 Pseudoephedrine in Tablets Definitively confirm the presence of illicit drug product using UHPLC/ MS, by creating and searching spectral libraries for fragmentation patterns produced through in-source CID Relative Abundance Relative Abundance Molecular Ion (low cone voltage) In-Source CID (high cone voltage) Pseudoephedrine (RT: 2.60min) m/z Hypersil GOLD PFP 1.9um, 100 x 2.1 mm; binary gradient of water and acetonitrile with acetic acid at 1 ml/min; 1 ul injection; ESI Positive 28
29 Salt Forms of Product Characterize illicit drugs and their precursors by distinguishing unique salt forms with low mass, polarity switching UHPLC/MS Bromide Iodide 20 Relative Abundance Phosphate Chloride Nitrate Chlorate Sulfate Perchlorate Amphetamine Meth 3,4-MDMA Cocaine Area (10 4 ) Chloride (RT: 1.59min) R 2 = LOQ = 50.0 ppb Time (min) Concentration (ppm) Identified Quantified Hypercarb 3um, 50 x 2.1 mm; binary gradient of water and methanol with formic acid at 300 ul/min; 2 ul injection; ESI Positive and Negative 29
30 Gunpowder in Particles Determine the make and manufacturer of gunpowder found in particles, pellets, and residue by characterizing their unique salt compositions through low mass, polarity switching UHPLC/MS Hodgdon Triple Seven Sodium Sodium Hodgdon Pyrodex Normalized Abundance Potassium Nitrate Gluconate Perchlorate Dicyandiamide Potassium Nitrate Gluconate Perchlorate Dicyandiamide Time (min) Benzoate Time (min) Benzoate Hypercarb 5um, 100 x 2.1 mm; binary gradient of water and methanol with formic acid at 300 ul/min; 5 ul injection; ESI Positive and Negative 30
31 Explosive Compounds in Soil Simultaneously analyze nitroamines, nitroaromatics, nitrate esters, and peroxide explosives by UHPLC/MS in under 15 minutes. Confirm the identifications by spectral library search. Peak Compound 1 HMTD Match scores 2 EGDN 3 TNB 4 DEGDN 5 HMX 6 1,3-DNB 7 RDX Target spectrum 8 TNT 9 2,6-DNT 10 NG 11 2,4-DNT 12 4-A-2,6-DNT Library spectrum 13 TATP 14 TETRYL 15 TMETN 16 2-A-4,6-DNT 17 PETN 31 Identified Confirmed
32 MSQ Plus Mass Detector: Advanced LC Detection For cost conscious chemists who require increased productivity through dependable simplicity, the Thermo Scientific MSQ is a turnkey UHPLC/MS solution providing superior chromatographic efficiency and enhanced mass detection with unsurpassed ease of use, performance, and ruggedness. 32
33 Thank you! Increase Productivity Ultra-Fast Speed, Resolution and Mass Detection 33
34 34 Thank you!
Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer
application Note Liquid Chromatography/ Mass Spectrometry Authors Sharanya Reddy Blas Cerda PerkinElmer, Inc. Shelton, CT USA Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate
More informationQualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection
Application Note Cannabis Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection Authors Mike Adams, Annette Roth, Sue D
More informationRapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition
Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Evelyn Goh Waters Pacific, Singapore APPLICATION BENEFITS This method allows for the simultaneous analysis of 12 water-soluble
More informationAgilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value
Agilent 64 Triple Quadrupole LC/MS Sensitivity, Reliability, Value Sensitivity, Reliability, Value Whether you quantitate drug metabolites, measure herbicide levels in food, or determine contaminant levels
More informationImpurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF
Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF PUSHER TOF DETECTOR ZSPRAY TM Ion Source SAMPLING CONE SKIMMER RF HEXAPOLE RF HEXAPOLE QUADRUPOLE IN NARROW BANDPASS MODE
More informationO O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions
Simplifying Qual/Quan Analysis in Discovery DMPK using UPLC and Xevo TQ MS Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION The determination of the drug metabolism
More informationLC-MS/MS Method for the Determination of Tenofovir from Plasma
LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract
More informationNew Solvent Grade Targeted for Trace Analysis by UHPLC-MS
New Solvent Grade Targeted for Trace Analysis by UHPLC-MS Subhra Bhattacharya, Deva H. Puranam, and Stephen C. Roemer Thermo Fisher Scientific Fisher Chemical, One Reagent Lane, Fair Lawn, NJ Material
More informationJoin the mass movement towards mass spectrometry
Join the mass movement towards mass spectrometry Thermo Scientific ISQ EC single quadrupole mass spectrometer Embrace the power of mass spectrometry Achieving a comprehensive understanding of the samples
More informationPolymer Additive Analysis by EI and APCI
Polymer Additive Analysis by EI and APCI Kate Yu, Eric Block LC/MS Waters Corporation Introduction to polymer additive analysis by LC/MS. Electron Ionization (EI) Advantages Classical spectra Library searchable
More informationCannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system
Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 9 Infinity II/63B LC/TOF system Application Brief Authors Mike Adams, Karen Kaikaris, and A. Roth CWC Labs Joan Stevens, Sue D
More informationThe Development of LC/MS Methods for Determination of Polar Drugs of Abuse in Biological Samples
WA20259 The Development of LC/MS Methods for Determination of Polar Drugs of Abuse in Biological Samples Michael S. Young and Kevin M. Jenkins Waters Corporation, 34 Maple Street, Milford, MA 01757 Introduction
More informationIdentification & Confirmation of Structurally Related Degradation Products of Simvastatin
Identification & Confirmation of Structurally Related Degradation Products of Simvastatin Power of QTRAP Systems for Identification and Confirmation of Degradation Products Dilip Reddy 1, Chandra Sekar
More informationUPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes
UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes Catalin E. Doneanu, Weibin Chen, and Jeffrey R. Mazzeo Waters Corporation, Milford, MA, U.S. A P P L I C AT ION B E N E F
More informationRapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer
Robert Plumb, Michael D. Jones, and Marian Twohig Waters Corporation, Milford, MA, USA INTRODUCTION The detection and characterization of impurities and degradation products of an active pharmaceutical
More informationLiquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188E
Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188E Ultra-High Sensitivity By incorporating newly improved ion optics and collision cell technology, the LCMS-8040 provides higher multiple reaction
More informationAutomated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System
Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System Keywords Introduction Application Note PHA0413 High Pressure Liquid Chromatography
More informationDetection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer
APPLICATION NOTE 72819 Detection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer Author Maria Grübner; Thermo Fisher Scientific, Germering,
More informationIntroduction to LC/MS/MS
Trends in 2006 Introduction to LC/MS/MS By Crystal Holt, LC/MS Product Specialist, Varian Inc. Toxicology laboratories Increased use of LC/MS Excellent LD Cheaper (still expensive) Much more robust Solves
More informationChemical Analysis Business Operations Waters Corporation Milford MA
The Detection and Identification of Unknown Contaminants During ToF Screening and Structural Elucidation for Pesticides in River Water Using an Integrated Software Approach Chemical Analysis Business Operations
More informationACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS
ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS Tanya Jenkins Waters Corporation, Milford, MA, USA INTRODUCTION Some of the most challenging methods
More informationKey Advantages of Comprehensive Cannabis Analysis
Comprehensive Cannabis Analysis: Pesticides, Aflatoxins, Terpenes, and High Linear Dynamic Range Potency from One Extract Using One Column and One Solvent System Robert Di Lorenzo 1, Diana Tran 2, KC Hyland
More informationAdvancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations
Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations For Research Use Only. Not for use in diagnostic procedures. 1 2015 AB Sciex RUO-MKT-11-1018-A For research
More informationThe Raptor HILIC-Si Column
The Raptor HILIC-Si Column With Raptor LC columns, Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or core-shell particles) with the resolution
More informationWorkflow for Screening and Quantification of the SAMHSA (NIDA) Panel in Urine Using UHPLC-TOF
APPLICATIO OTE Liquid Chromatography/ Mass Spectrometry Authors: Avinash Dalmia Joanne Mather PerkinElmer, Inc. Shelton, CT Workflow for Screening and Quantification of the SAMHSA (IDA) Panel in Urine
More informationapplication Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS
application LC/MS Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS Introduction Many kinds of natural colors are used in beverages,
More informationIncreased Identification Coverage and Throughput for Complex Lipidomes
Increased Identification Coverage and Throughput for Complex Lipidomes Reiko Kiyonami, David Peake, Yingying Huang, Thermo Fisher Scientific, San Jose, CA USA Application Note 607 Key Words Q Exactive
More informationAuthors. Abstract. Introduction. Environmental
Determination of Ultratrace Amitrol in Water Samples by in situ Derivatization-Solid Phase Extraction-Liquid Chromatography-Mass Selective Detector Application Environmental Authors Gerd Vanhoenacker,
More informationQuantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 6410 Triple Quadrupole LC/MS system
Quantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 641 Triple Quadrupole LC/MS system Application Note Clinical Research Author Siji Joseph Agilent Technologies Bangalore, India
More informationRobust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS
TECHNICAL NOTE 21882 Robust extraction, separation, and quantitation of structural isomer steroids human plasma by SPE-UHPLC-MS/MS Authors Jon Bardsley 1, Kean Woodmansey 1, and Stacy Tremintin 2 1 Thermo
More informationInternational Journal of Applied Pharmaceutical Sciences and Research
International Journal of Applied Pharmaceutical Sciences and Research 2017; 2(3): 55-63 Anas et al/international Journal of Applied Pharmaceutical Sciences and Research 2017; 2(3): 55-63 International
More informationAgilent 7700x ICP-MS
Agilent 7700x ICP-MS Metals analysis Mid ppt to low ppb detection range Option to detect in four different gas modes to gain optimum detection of multiple metals or interferences in a sample Autosampler
More informationAmphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS
Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 643 LC/MS/MS Application Note Forensics Authors Jason Hudson, Ph.D., James Hutchings, Ph.D., and Rebecca Wagner, Ph.D. Virginia
More informationSingle Quadrupole Compact Mass Spectrometer for Liquid Sample
Single Quadrupole Compact Mass Spectrometer for Liquid Sample YL INSTRUMENT CO., LTD. YL9900 MS quickly provides essential information and improves the chemist's workflow. Mordern organic labs have become
More informationApplying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis
Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis Ying Qing Yu Waters Corporation, Milford, MA, USA APPLICATION BENEFITS
More informationRapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS
Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS Mark Ritchie and Evelyn Goh Waters Pacific Pte Ltd., Singapore A P P L I C AT ION B E N E F I T S Delivers a rapid 10-min MRM method
More informationA RAPID AND SENSITIVE UPLC/UV/MS METHOD FOR SIMVASTATIN AND LOVA S TAT IN IN SU P P O RT O F C L E A NING VA L I DAT IO N S T U DIES
RPID ND SENSITIVE PLC/V/MS METD FR SIMVSTTIN ND LV S TT IN IN S P P RT F C L E NING V L I DT I N S T DIES Erin Chambers, Diane Diehl, and Jeff Mazzeo Waters Corporation, Milford, M, S BCKGRND tilizing
More informationIC-MS Environmental Applications - Water Testing. Application Notebook
IC-MS Environmental Applications - Water Testing Application Notebook Table of Contents Environmental Sample Using IC-MS 3 Environmental Applications: Water Testing Acrylamide in Water 4 Trace Urea in
More informationApplication Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.
Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice Application Note Author Food Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India 8 6 4 2
More informationSimple Method (IS-MRM) to Monitor Lysophospholipids and Phospholipids During LC-MS Method Development via In-Source CID
Simple Method (IS-MRM) to Monitor Lysophospholipids and Phospholipids During LC-MS Method Development via In-Source CID James Little, Eastman Chemical Company, Kingsport, TN Overview Phospholipids and
More informationSPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine
SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA
More informationMS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine
Application Note: 346 MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine Gargi Choudhary and Diane Cho, Thermo Fisher Scientific, San Jose, CA Wayne Skinner and
More informationIdentification and Quantification at ppb Levels of Common Cations and Amines by IC-MS
Application Note 269 Identification and Quantification at ppb Levels of Common Cations and Amines by IC-MS INTRODUCTION Ion chromatography (IC) has been extensively used as the preferred separation technique
More informationShuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W
Simple, Fast and Accurate Quantitation of Human Plasma Vitamins and Their Metabolites by Protein Precipitation Combined with Columns Using HPLC-UV, HPLC-FLD or LC/MS/MS Shuguang Li, Jason Anspach, Sky
More informationQuadrupole and Ion Trap Mass Analysers and an introduction to Resolution
Quadrupole and Ion Trap Mass Analysers and an introduction to Resolution A simple definition of a Mass Spectrometer A Mass Spectrometer is an analytical instrument that can separate charged molecules according
More informationRapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column
APPLICATION NOTE 21673 Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column Authors Aaron Lamb and Brian King, Thermo Fisher Scientific, Runcorn, UK
More informationIdentification of Steroids in Water by Ion Trap LC/MS/MS Application
Identification of Steroids in Water by Ion Trap LC/MS/MS Application Environmental Author Paul Zavitsanos and Christine Miller Agilent Technologies, Inc. Centerville Road Wilmington, DE 9- USA Abstract
More information[ APPLICATION NOTE ] Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector
Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector Mark Benvenuti, Gareth Cleland, and Jennifer Burgess Waters Corporation, Milford, MA, USA
More informationBreaking the Sensitivity Barrier in Triple Quad LC/MS Performance
Breaking the Sensitivity Barrier in Triple Quad LC/MS Performance Tim Schlabach Alex Mordehai Michael Zumwalt Page 1 Sensitivity enhancements for ESI-MS Reduce the column diameter! 30 fold gains in sensitivity
More informationSupporting information
Supporting information Figure legends Supplementary Table 1. Specific product ions obtained from fragmentation of lithium adducts in the positive ion mode comparing the different positional isomers of
More informationEvaluation of UHPLC System Performance Under High Throughput Conditions. William Hedgepeth, Masatoshi Takahashi, Shimadzu Scientific Instruments
Evaluation of UHPLC System Performance Under High Throughput Conditions William Hedgepeth, Masatoshi Takahashi, Shimadzu Scientific Instruments Introduction The use of UHPLC technology has continued to
More informationApplication of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices
Application ote #LCMS-2 esquire series Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices Introduction The simple monitoring
More informationA Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography
Application Note LCMS-109 A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography Time of Flight (LC-TOF) Mass Spectrometry Introduction Many clinical
More informationAnalysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research
Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research Dominic Foley, Michelle Wills, and Lisa Calton Waters Corporation, Wilmslow, UK APPLICATION
More informationInternational Journal of Applied Pharmaceutical Sciences and Research
International Journal of Applied Pharmaceutical Sciences and Research Research Article http://dx.doi.org/10.21477/ijapsr.v2i03.8254 Analytical Separation and Characterisation of Degradation Products and
More informationQuantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System
Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System Marta Kozak Clinical Research Applications Group Thermo Fisher Scientific San Jose CA Clinical Research use only, Not for
More informationDetermination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.
Page 1 of 10 Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection EPL-BAS Method No. 205G881B Method Summary: Residues of 6-CPA are
More informationSue D Antonio Application Chemist Cedar Creek, TX
Sue D Antonio Application Chemist Cedar Creek, TX What is Hemp Oil? CBD hemp oil is a natural botanical extract of the common hemp plant. CBD hemp oil is derived from the seeds and stem of the Cannabis
More informationUltra High Performance Liquid Chromatograph. Nexera X2 C196-E079
Ultra High Performance Liquid Chromatograph Nexera X2 C196-E79 Maximizing the Potential of UHPLC/HPLC Analyses Intelligence Intelligent data solutions, including a new i -PDeA peak calculation method for
More informationQuantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics
Quantitative Analysis of piates in Urine Using RRHT LC/MS/MS Application Forensics Authors Sheher Mohsin Agilent Technologies, Inc. 10 N. Martingale Rd., Suite 550 Schaumburg, IL 60173 USA Yanan Yang Agilent
More informationSWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids
SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids Data Independent Acquisition on TripleTOF and X-Series QTOF Systems for Seized Drug Analysis Oscar G. Cabrices
More informationLECTURE 3. Ionization Techniques for Mass Spectrometry
LECTURE 3 Ionization Techniques for Mass Spectrometry Jack Henion, Ph.D. Emeritus Professor, Analytical Toxicology Cornell University Ithaca, NY 14850 Lecture 3, Page 1 Contents Electron ionization (EI)
More informationBioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS
Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS Jenny Chen, Hongxia Wang, Zhiqi Hao, Patrick Bennett, and Greg Kilby Thermo Fisher
More informationDetection of Cannabinoids in Oral Fluid with the Agilent 7010 GC-MS/MS System
Application Note Forensics, Workplace Drug Testing Detection of Cannabinoids in Oral Fluid with the Agilent 7010 GC-MS/MS System Authors Fred Feyerherm and Anthony Macherone Agilent Technologies, Inc.
More informationMS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager
MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager Quick Start Guide Step 1. Calibrate the Q-TOF LC/MS for low m/z ratios 2 Step 2. Set up a Flow Injection Analysis (FIA) method for
More informationDesigner Cannabinoids
Liquid Chromatography Mass Spectrometry SSI-LCMS-010 Designer Cannabinoids LCMS-8030 Summary A rapid LC-MS-MS method for determination of designer cannabinoids in smokeable herbs was developed. Background
More informationMASS SPECTROMETRY BASED METABOLOMICS. Pavel Aronov. ABRF2010 Metabolomics Research Group March 21, 2010
MASS SPECTROMETRY BASED METABOLOMICS Pavel Aronov ABRF2010 Metabolomics Research Group March 21, 2010 Types of Experiments in Metabolomics targeted non targeted Number of analyzed metabolites is limited
More informationVitamin D3 and related compounds by ESI and APCI
Liquid Chromatography Mass Spectrometry SSI-LCMS-9 Vitamin D and related compounds by ESI and APCI LCMS-8 Summary Vitamin D and related compounds were measured by LC-ESI/APCI-MS-MS. Background Accurate
More informationAnalysis of Pesticides (II) Metribuzin & their metabolites in Rice Jun Yonekubo, Nihon Waters, JAPAN
Waters Alliance LC/MS System Analytical Conditions Chromatograms Mass Spectra Calibration Quantitation Analysis of Pesticides (II) Metribuzin & their metabolites in Rice Jun Yonekubo,, JAPAN Key Words
More informationDetermination of Amantadine Residues in Chicken by LCMS-8040
Liquid Chromatography Mass Spectrometry Determination of Amantadine Residues in Chicken by LCMS-8040 A method for the determination of amantadine in chicken was established using Shimadzu Triple Quadrupole
More informationUltra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification
22 SEPARATION SCIENCE REDEFINED MAY 2005 Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification In the drug discovery process the detection and
More informationAgilent s LC/MS Portfolio and Applications Examples
Agilent s LC/MS Portfolio and Applications Examples Sean Orlowicz LC/MS Product Specialist Agilent Technologies 31August Agilent s > 40 year heritage in mass spectrometry 1971, 5930A GC/MS 1971-2011 2005,
More informationAuthor. Introduction. Abstract
Simultaneous Measurement of Sirolimus and Tacrolimus Concentrations in Blood by Semi-Automated Extraction and Liquid Chromatography-Electrospray Ionization Mass Spectrometry Application Author Gary L.
More informationTime-of-Flight LC/MS Identification and Confirmation of a Kairomone in Daphnia magna Cultured Medium. Application. Authors. Abstract.
Time-of-Flight LC/MS Identification and Confirmation of a Kairomone in Daphnia magna Cultured Medium Application Natural Product Chemistry Authors Hideaki Uchida Agilent Technologies Japan, Ltd. Tokyo
More informationUsing Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.
Using Software Tools to Improve the Detection of Impurities Application Note Christine Miller Introduction The analysis of raw materials and finished products for or impurities presents a challenge in
More informationFast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS
TECHNICAL NOTE 21883 Fast and easy separation of 23 drugs of abuse including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS Authors Kean Woodmansey 1, Jon Bardsley 1 and Stacy
More informationComprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids
PO-CON1576E Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids HPLC 2015 PSB-MULTI-06 Yoshiyuki WATABE, Tetsuo IIDA, Daisuke NAKAYAMA, Kanya TSUJII, Saki
More informationApplication Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer
Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer Abstract This study demonstrates a sensitive, rapid and reliable research
More informationCONTENT. i iv ix. SVKM s NMIMS, School of Pharmacy and Technology Management
CONTENT Chapter No. Title Page No. Abbreviations List of Figures List of Tables 1 Introduction 1 1.1 Practical aspects 4 1.2 Stability-indicating assay method (SIAM) 5 1.3 Regulatory aspects 6 1.4 Techniques
More informationMeasuring Phytosterols in Health Supplements by LC/MS. Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA
Measuring Phytosterols in Health Supplements by LC/MS Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA Overview Purpose: Develop a method for the extraction of phytosterols
More informationDETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS
FORENSICS AND TOXICOLOGY ANALYSIS DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS Solutions for Your Analytical Business Markets and Applications
More informationSUPPORTING INFORMATION FOR: CONCENTRATIONS OF POLYBROMINATED DIPHENYL ETHERS, HEXABROMOCYCLODODECANES AND TETRABROMOBISPHENOL-A IN BREAST MILK FROM
SUPPORTING INFORMATION FOR: CONCENTRATIONS OF POLYBROMINATED DIPHENYL ETHERS, HEXABROMOCYCLODODECANES AND TETRABROMOBISPHENOL-A IN BREAST MILK FROM UNITED KINGDOM WOMEN DO NOT DECREASE OVER TWELVE MONTHS
More informationTHE POWER OF MASS SPECTROMETRY FOR IC ANALYTICAL CHEMISTS. Unleash New Possibilities with Enhanced Detection for IC Applications
THE PWER F MA PECTRMETRY FR IC ANALYTICAL CHEMIT Unleash New Possibilities with Enhanced Detection for IC Applications THE PWER F MA PECTRMETRY Ion chromatography (IC) excels in analyzing ionic species
More informationWorkflow for Screening and Quantification of the SAMHSA (NIDA) Panel in Serum Using UHPLC-TOF
APPLICATIO OTE Liquid Chromatography/ Mass Spectrometry Authors: Avinash Dalmia Bonnie Marmor PerkinElmer, Inc. Shelton, CT Workflow for Screening and Quantification of the SAMHSA (IDA) Panel in Serum
More informationMore structural information with MS n
PRODUCT SPECIFICATIONS The LTQ XL linear ion trap mass spectrometer More structural information with MS n The LTQ XL linear ion trap mass spectrometer delivers more structural information faster and with
More informationProbing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION
Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection Michael Jones Waters Corporation, Wilmslow, UK APPLICATION BENEFITS The ACQUITY Arc System is
More informationLiquid Chromatograph Mass Spectrometer LCMS-8050 C146-E232A
Liquid Chromatograph Mass Spectrometer LCMS-85 C146-E232A Speed and Sensitivity Beyond Comparison Continuing the evolution of Shimadzu's UF technology, Shimadzu introduces the LCMS-85 triple quadrupole
More informationNew Instruments and Services
New Instruments and Services Liwen Zhang Mass Spectrometry and Proteomics Facility The Ohio State University Summer Workshop 2016 Thermo Orbitrap Fusion http://planetorbitrap.com/orbitrap fusion Thermo
More informationLC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ
LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ Anthony Sullivan, LC/MS Product Specialist Melanie Mülek and Christoph Müller LC-MS Applications Specialists Hewlett-Packard-Str.
More informationCharacterization of an Unknown Compound Using the LTQ Orbitrap
Characterization of an Unknown Compound Using the LTQ rbitrap Donald Daley, Russell Scammell, Argenta Discovery Limited, 8/9 Spire Green Centre, Flex Meadow, Harlow, Essex, CM19 5TR, UK bjectives unknown
More informationAnalysis of several common. organic acids in tobacco leaf, snus, and moist snuff
Analysis of several common organic acids in tobacco leaf, snus, and moist snuff S. C. Moldoveanu, W. A. Scott R.J. Reynolds Tobacco Co. Background Among the organic acids commonly present in tobacco, are
More informationAnalysis of the Non-Ionic Surfactant Triton-X Using UltraPerformance Convergence Chromatography (UPC 2 ) with MS and UV Detection
Analysis of the Non-Ionic Surfactant Triton-X Using UltraPerformance Convergence Chromatography (UPC 2 ) with MS and UV Detection Jane Cooper, 1 Baiba Cabovska 2 1 Waters Corporation, Wilmslow, UK 2 Waters
More informationAnalysis of HMF by HPLC
COST Action 927 Training School Building Skills on the Analysis of Thermal Process Contaminants in Foods 22-26 October 2007, Ankara Analysis of HMF by HPLC Vural Gökmen O O OH Background O COOH O R 2 Carbonyl
More informationAmadeo R. Fernández-Alba
% of compounds % of compounds % of compounds % of compounds Amadeo R. Fernández-Alba LC-Orbitrap QExactive Focus Instrumental LOQ 1% 9% 8% 7% 6% 5% 4% 3% 2% 1% %.1 mg/g.2 mg/g Tomato.5 mg/g ddms2 Target
More informationApplication Note. Author. Abstract. Introduction. Food Safety
Determination of β2-agonists in Pork with SPE eanup and LC-MS/MS Detection Using Agilent BondElut PCX Solid-Phase Extraction Cartridges, Agilent Poroshell 120 column and Liquid Chromatography-Tandem Mass
More informationEdgar Naegele. Abstract
Simultaneous determination of metabolic stability and identification of buspirone metabolites using multiple column fast LC/TOF mass spectrometry Application ote Edgar aegele Abstract A recent trend in
More informationSample Concentration and Analysis of Human Hormones in Drinking Water
Sample Concentration and Analysis of Human Hormones in Drinking Water Carl Fisher Applications Chemist Ion Chromatography/Sample Preparation Thermo Fisher Scientific March 1, 215 1 The world leader in
More information[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS
[ APPLICATI TE ] Ion Mobility-enabled Data-dependent Experiments Distinguishing Co-eluting Isomeric Metabolites Using an IMS-QTof Mass Spectrometer Jayne Kirk, 1 Russell Mortishire Smith, 1 Robert Beecher,
More informationDetermination of Multi-Residue Tetracyclines and their Metabolites in Milk by High Performance Liquid Chromatography - Tandem Mass Spectrometry
Determination of Multi-Residue Tetracyclines and their Metabolites in Milk by igh Performance Liquid Chromatography - Tandem Mass Spectrometry Application ote Food Authors Yanyan Fang, ao Zhai, and Yun
More information