1 LECTURE 3 Ionization Techniques for Mass Spectrometry Jack Henion, Ph.D. Emeritus Professor, Analytical Toxicology Cornell University Ithaca, NY Lecture 3, Page 1
2 Contents Electron ionization (EI) Electrospray ionization (ESI) Nano ESI Atmospheric pressure chemical ionization ( APCI) Atmospheric pressure photoionization ( APPI) Matrix assisted laser desorption ionization (MALDI) LAESI Direct analysis in real time (DART) Desorption electrospray ionization (DESI) Atmospheric sampling analysis probe (ASAP) And there are many more that may or may not mature. Lecture 3, Page 2
3 Many Forms of Ionization have been Reported EI APCI ESI APPI ASAP MALDI DESI RADIO DAPPI REIMS PESI LIAD-ESI DART FAPA LAESI/IR- LDESI/MALDESI ELDI LIAD-ESI Lecture 3, Page 3
4 Electron Ionization (EI) Source (not yet commercially available for LC/MS) High vacuum Lecture 3, Page 4
5 Ionization Processes: Electron Ionization (EI) vs. API Electron ionization (EI) forms radical cations as shown below: M e - M. 2 e - 70 ev electrons The radical cation is very reactive and often is the primary director of the ensuing fragmentation API techniques generate (M1) ions as shown below: Electrospray or APCI: (MH) (MH) (in solution) (ion evaporation or APCI) (gas-phase ion) But how does this occur? Lecture 3, Page 5
6 Positive Ions: Odd-Electron and Even-Electron Ions Odd Electron Ions N H H H e N H H H EE (8) OE (7) 2e Even Electron Ions N H H H H H N H H H EE (8) EE (8) Lecture 3, Page 6 OE and EE Ions
7 Electrospray Ionization Lecture 3, Page 7
8 Electrospray Process A method by which ions present in solution can be transferred to the gas phase High Flow ESI Gas Assisted: Droplet size influenced by high velocity gas & electrostatic repulsion Classical or Pure ESI or NSI: Droplet Size influenced purely by electrostatic repulsion Courtesy ThermoFinnigan Lecture 3, Page 8
9 Ink Jet printing Taylor Cone 8 x 10-3 Torr kv OXIDATION electrons High-Voltage Power Supply electrons 1 kv REDUCTION Lecture 3, Page 9
10 Maximizing Signal. Minimizing Noise. Agilent Animation of S/N Lecture 3, Page 10
11 AB SCIEX Turbo-V Gas Entrainment Source High sensitivity at any flow rate. 1. Increased Thermal Efficiency of Heater 2. Second Heater Double Thermal Load 3. Promote Turbulent Mixing Improved Heat and Mass Transfer Maximize Desolvation 4. Controlled Entrainment Background Reduction 5. Reduced Dispersion of Droplets Signal Enhancement Flow Rate Dependent Lecture 3, Page 11
12 Electrospray Ionization Technology Enhancements: Thermo HESI-II Benefits: Sensitivity across a wider range of flow rates Higher desolvation for >1mL/min flow rates More heated nitrogen auxiliary gas flow aids desolvation at high flow rates One piece metal needle allows for easy replacement Available as low flow and regular (high) flow Contoured tip for enhanced low flow (micro-spray; 5-25uL) stability Generates better electrostatic fields enabling spray stability for lower flow rates * Available on all TSQ products Higher desolvation Contoured tip Metal Needle Standard Lecture 3, Page 12
13 Waters Z-Spray Synapt HDMS System Lecture 3, Page 13
14 Agilent Jet Stream Technology Courtesy of Dr. Alex Mordehai, Agilent Technologies Lecture 3, Page 14
15 H-SRM Operation Enhancing Specificity Lower chemical noise Lower detection limits Collision Cell = only pre-cursor ion transmitted Thermo TSQ Quantum Lecture 3, Page 15
16 Enhancing Detection Limits 90º Collision Cell Design No Line of sight enhanced S/N 5x better SRM transmission efficiency Argon as collision gas for higher sensitivity Exit lens assembly Collision cell housing Entrance lens assembly Square quadrupole collision cell Lecture 3, Page 16
17 A trace of DMSO to Improve Peptide Ionization Reponse Page 17 Jesse G. Meyer, Elizabeth A. Komives, Charge State Coalescence During Electrospray Ionization Improves Peptide Identification by Tandem Mass Spectrometry, J. Am. Soc. Mass Spectrom. (2012) 23:1390Y1399.
18 APPI Atmospheric Pressure Photoionization Lecture 3, Page 18
19 Molecular Weight APPI Source and Compound Strike Zone 100,000 10,000 Electrospray Ionization 1, APPI APCI Non-Polar Polarity Very Polar APPI source configuration employing a VUV light source and orthogonal spray geometry. Qualitative diagram representing ionization of nonpolar compounds by APPI Lecture 3, Page 19
20 Direct vs. Dopant APPI Direct APPI M hv M M S MH S[-H] Analyte molecule M is ionized to a molecular ion M. (If analyte ionization potential is below photon energy) In the presence of protic solvents, M may abstract a hydrogen atom to form MH. Dopant APPI D hv D D M MH D[-H] D M M D A photoionizable dopant is delivered in large concentration to yield many D ions. D ionizes analyte M by proton or electron transfer. This is PI-initiated APCI. Lecture 3, Page 20
21 Benefits of APPI Ionizes a relatively wide range of compounds (e.g., non-polars, electronegative cpds, etc.) Predominantly parent ion signal (minimum fragmentation) Low noise source (minimum solvent signal) Minimum ion suppression Large linear dynamic range Works for positive and negative ionization Lecture 3, Page 21
22 Peak Area Peak Area APPI Is Best For 1.2E05 1.0E05 8.0E04 Dibenzo[a,h]anthracene, 278 > ,000 pg R 2 = E04 Environmental 4.0E04 PAHs 2.0E04 Steroids 0.0E00 Pesticides Injection Amount (pg) Food Safety PAHs 2.E06 >5-decade linear Pesticides response on 2.E06 the ZQ Fish Oil Lipids R 2 = Vitamins 1.E Petroleum/Oils/Biofuels E05 Petroleum 0 Biofuels 0.E00 Triacylglycerol Lipids Inj. Amount (ng) Pharmaceuticals/Small Molecules Steroids Metabolites (especially lacking functional groups) Chiral Separations (i.e., normal phase LC) Analysis of Lipids: Diarachidin (1:1 100 ul/min) R 2 = >10 4 linear response 100 % ESI APPI Progesterone [MH] % Ion m ass Lecture 3, Page 22
23 APPI Very Resistant to Ion/Matrix Suppression APPI TIC Full Scan - Rat Plasma Extract Ratio of signal for FIA/MS vs. LC/MS APPI APCI ESI APPI Average deviation 74% 57% 23% Median deviation 68% 52% 22% APCI Measurement performed on a 29-compound library of unknown purity ESI Determination of ion suppression susceptibility for APPI, APCI, and ESI by post-column addition and detection of fluphenazine while running an LC/MS chromatogram of rat plasma. min These results show minimal ion suppression by APPI. APCI shows less ion suppression than ESI, but APCI signal is noisier than by APPI Lecture 3, Page 23
Introduction to LC/MS/MS
Trends in 2006 Introduction to LC/MS/MS By Crystal Holt, LC/MS Product Specialist, Varian Inc. Toxicology laboratories Increased use of LC/MS Excellent LD Cheaper (still expensive) Much more robust Solves
More informationAgilent s LC/MS Portfolio and Applications Examples
Agilent s LC/MS Portfolio and Applications Examples Sean Orlowicz LC/MS Product Specialist Agilent Technologies 31August Agilent s > 40 year heritage in mass spectrometry 1971, 5930A GC/MS 1971-2011 2005,
More informationAnalyzing Phenyl Ureas and Carbamates with HPLC/API-MS. Presented by Chen-Kai Meng, Ph.D. Applications Chemist
Analyzing Phenyl Ureas and Carbamates with HPLC/API-MS Presented by Chen-Kai Meng, Ph.D. Applications Chemist Outline Overview of ESI, APPI, and APCI sources Comparing ESI, APPI, and APCI results Identifying
More informationMethods in Mass Spectrometry. Dr. Noam Tal Laboratory of Mass Spectrometry School of Chemistry, Tel Aviv University
Methods in Mass Spectrometry Dr. Noam Tal Laboratory of Mass Spectrometry School of Chemistry, Tel Aviv University Sample Engineering Chemistry Biology Life Science Medicine Industry IDF / Police Sample
More informationAgilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value
Agilent 64 Triple Quadrupole LC/MS Sensitivity, Reliability, Value Sensitivity, Reliability, Value Whether you quantitate drug metabolites, measure herbicide levels in food, or determine contaminant levels
More informationBreaking the Sensitivity Barrier in Triple Quad LC/MS Performance
Breaking the Sensitivity Barrier in Triple Quad LC/MS Performance Tim Schlabach Alex Mordehai Michael Zumwalt Page 1 Sensitivity enhancements for ESI-MS Reduce the column diameter! 30 fold gains in sensitivity
More informationSCS Mass Spectrometry Laboratory
SCS Mass Spectrometry Laboratory Contact Information Staff 31 Noyes Laboratory (8:00-5:00 M-F) 217-333-2545 http://scs.illinois.edu/massspec/ Furong Sun (frs@illinois.edu) Furong Sun Director Training
More informationQuadrupole and Ion Trap Mass Analysers and an introduction to Resolution
Quadrupole and Ion Trap Mass Analysers and an introduction to Resolution A simple definition of a Mass Spectrometer A Mass Spectrometer is an analytical instrument that can separate charged molecules according
More informationMolecular Cartography:
Molecular Cartography: Moving Towards Combined Topographical and Chemical Imaging Using AFM and Mass Spectrometry Olga S. Ovchinnikova Organic and Biological Mass Spectrometry Group, Chemical Sciences
More informationIonization Methods. Neutral species Charged species. Removal/addition of electron(s) Removal/addition of proton(s)
Ionization Methods Neutral species Charged species Removal/addition of electron(s) M + e - (M +. )* + 2e - electron ionization Removal/addition of proton(s) M + (Matrix)-H MH + + (Matrix) - chemical ionization
More informationPolymer Additive Analysis by EI and APCI
Polymer Additive Analysis by EI and APCI Kate Yu, Eric Block LC/MS Waters Corporation Introduction to polymer additive analysis by LC/MS. Electron Ionization (EI) Advantages Classical spectra Library searchable
More informationMaking your LC Method Compatible with Mass Spectrometry
Making your LC Method Compatible with Mass Spectrometry Technical Overview Author Edgar aegele Agilent Technologies, Inc. Waldbronn, Germany Introduction The power of traditional high-performance liquid
More informationMass Spectrometry Course Árpád Somogyi Chemistry and Biochemistry MassSpectrometry Facility) University of Debrecen, April 12-23, 2010
Mass Spectrometry Course Árpád Somogyi Chemistry and Biochemistry MassSpectrometry Facility) University of Debrecen, April 12-23, 2010 Introduction, Ionization Methods Mass Analyzers, Ion Activation Methods
More informationMetabolomics: quantifying the phenotype
Metabolomics: quantifying the phenotype Metabolomics Promises Quantitative Phenotyping What can happen GENOME What appears to be happening Bioinformatics TRANSCRIPTOME What makes it happen PROTEOME Systems
More informationIon Suppression Minimized in LC/MSD
Welcome to our E-Seminar: Ion Suppression Minimized in LC/MSD Outline What is ion/signal suppression and why Approaches to minimize suppression Different ionization process ESI source design Fruit and
More informationFundamentals of Soft Ionization and MS Instrumentation
Fundamentals of Soft Ionization and MS Instrumentation Ana Varela Coelho varela@itqb.unl.pt Mass Spectrometry Lab Analytical Services Unit Index Mass spectrometers and its components Ionization methods:
More informationOzonolysis of phospholipid double bonds during electrospray. ionization: a new tool for structure determination
Ozonolysis of phospholipid double bonds during electrospray ionization: a new tool for structure determination Michael C. Thomas, Todd W. Mitchell, Stephen J. Blanksby Departments of Chemistry and Biomedical
More informationCalifornia TOF/QTOF Users Meetings: MS Settings. Jim Lau, Agilent Technologies.
California TOF/QTOF Users Meetings: MS Settings Jim Lau, Agilent Technologies. Data Acquisition Overview How to Improve Performance Optimize Source Parameters: Drying Gas Temperature, Gas Flow, and Neb
More informationMSQ. Hardware. Document No Revision 02 October 2003
MSQ Hardware Document No. 031871 Revision 02 October 2003 2003 by Dionex Corporation All rights reserved worldwide. Printed in the United States of America. This publication is protected by federal copyright
More informationMore structural information with MS n
PRODUCT SPECIFICATIONS The LTQ XL linear ion trap mass spectrometer More structural information with MS n The LTQ XL linear ion trap mass spectrometer delivers more structural information faster and with
More informationBiological Mass Spectrometry. April 30, 2014
Biological Mass Spectrometry April 30, 2014 Mass Spectrometry Has become the method of choice for precise protein and nucleic acid mass determination in a very wide mass range peptide and nucleotide sequencing
More informationThree and Four Mass Spectrometers t in Parallel for Lipid Analysis How Many Instruments are Enough?
Three and Four Mass Spectrometers t in Parallel l for Lipid Analysis How Many Instruments are Enough? Wm. Craig Byrdwell Food Composition and Methods Development Laboratory USDA, ARS, Beltsville Human
More informationSample Concentration and Analysis of Human Hormones in Drinking Water
Sample Concentration and Analysis of Human Hormones in Drinking Water Carl Fisher Applications Chemist Ion Chromatography/Sample Preparation Thermo Fisher Scientific March 1, 215 1 The world leader in
More informationChip-Based E-Tip SPE followed by Infusion MS. Copyright by Jack Henion, 2015 Lecture 1, Page 30
Chip-Based E-Tip SPE followed by Infusion MS Copyright by Jack Henion, 2015 Lecture 1, Page 30 Infusion -MS Analysis of Sample Mixtures HPLC Mass Spec Elution/spray solvent Pipette tip with micro SPE packing
More informationMetabolomic fingerprinting of serum samples by direct infusion mass spectrometry
Metabolomic fingerprinting of serum samples by direct infusion mass spectrometry Raúl González-Domínguez * Department of Chemistry, Faculty of Experimental Sciences. University of Huelva, Spain. * Corresponding
More informationSmall Molecule Science: Experimental designs for achieving ultra trace analysis
Small Molecule Science: Experimental designs for achieving ultra trace analysis Michael P. Balogh Principal scientist Waters Corporation 211 Waters Corporation 1 www.cosmoscience.org The Society for Small
More informationMALDI-TOF. Introduction. Schematic and Theory of MALDI
MALDI-TOF Proteins and peptides have been characterized by high pressure liquid chromatography (HPLC) or SDS PAGE by generating peptide maps. These peptide maps have been used as fingerprints of protein
More informationMass Spectrometry Introduction
Mass Spectrometry Introduction Chem 744 Spring 2013 What MS is and is not MS is NOT a spectroscopic method. Molecules are not absorbing EM radiation MS is the generation, separation and characterization
More informationAgilent 6490 Triple Quadrupole LC/MS System with ifunnel Technology. Ultra sensitive quantitative performance
Agilent 6490 Triple Quadrupole LC/MS System with ifunnel Technology Ultra sensitive quantitative performance Unmatched quantitative performance for the most challenging analyses The Agilent 6490 Triple
More informationDetection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer
APPLICATION NOTE 72819 Detection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer Author Maria Grübner; Thermo Fisher Scientific, Germering,
More informationLC/MS/MS Analysis of Gabapentin, and Opiates. Applications. Presentation Outline. Polarity, MW and Volatility LC/MS Triple Quad Components
Presentation Outline LC/MS/MS Analysis of Gabapentin, LC/MS/MS Benzodiazepines, Introduction and Applications and Opiates Brian Nies LC/MS Product Specialist Varian Inc. Winter CAT Meeting Redondo Beach
More informationLC/MS Crossroads. Jerry Pappas Sales Representative 265 Davidson Avenue Somerset, NJ
LC/MS Crossroads Jerry Pappas Sales Representative 265 Davidson Avenue Somerset, NJ 08873 jerry.pappas@thermo.com 732-698-2778 1 Comparison of Quads and Traps Ion Traps Quadrupoles Mass Separation in time
More informationSupplementary Information
Supplementary Information Molecular imaging of brain localization of liposomes in mice using MALDI mass spectrometry Annabelle Fülöp 1,2, Denis A. Sammour 1,2, Katrin Erich 1,2, Johanna von Gerichten 4,
More informationSUPPORTING INFORMATION FOR: CONCENTRATIONS OF POLYBROMINATED DIPHENYL ETHERS, HEXABROMOCYCLODODECANES AND TETRABROMOBISPHENOL-A IN BREAST MILK FROM
SUPPORTING INFORMATION FOR: CONCENTRATIONS OF POLYBROMINATED DIPHENYL ETHERS, HEXABROMOCYCLODODECANES AND TETRABROMOBISPHENOL-A IN BREAST MILK FROM UNITED KINGDOM WOMEN DO NOT DECREASE OVER TWELVE MONTHS
More informationVitamin D3 and related compounds by ESI and APCI
Liquid Chromatography Mass Spectrometry SSI-LCMS-9 Vitamin D and related compounds by ESI and APCI LCMS-8 Summary Vitamin D and related compounds were measured by LC-ESI/APCI-MS-MS. Background Accurate
More informationSPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine
SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA
More informationNeosolaniol. [Methods listed in the Feed Analysis Standards]
Neosolaniol [Methods listed in the Feed Analysis Standards] 1 Simultaneous analysis of mycotoxins by liquid chromatography/ tandem mass spectrometry [Feed Analysis Standards, Chapter 5, Section 1 9.1 ]
More informationAgilent 7700x ICP-MS
Agilent 7700x ICP-MS Metals analysis Mid ppt to low ppb detection range Option to detect in four different gas modes to gain optimum detection of multiple metals or interferences in a sample Autosampler
More informationLC/MS Method for Comprehensive Analysis of Plasma Lipids
Application Note omics LC/MS Method for Comprehensive Analysis of Plasma s Authors Tomas Cajka and Oliver Fiehn West Coast Metabolomics Center, University of California Davis, 451 Health Sciences Drive,
More informationapplication Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS
application LC/MS Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS Introduction Many kinds of natural colors are used in beverages,
More information2. Ionization Sources 3. Mass Analyzers 4. Tandem Mass Spectrometry
Dr. Sanjeeva Srivastava 1. Fundamental of Mass Spectrometry Role of MS and basic concepts 2. Ionization Sources 3. Mass Analyzers 4. Tandem Mass Spectrometry 2 1 MS basic concepts Mass spectrometry - technique
More informationIdentification and Quantification at ppb Levels of Common Cations and Amines by IC-MS
Application Note 269 Identification and Quantification at ppb Levels of Common Cations and Amines by IC-MS INTRODUCTION Ion chromatography (IC) has been extensively used as the preferred separation technique
More informationEnhanced LC-MS Sensitivity of Vitamin D Assay by Selection of Appropriate Mobile Phase
Enhanced LC-MS Sensitivity of Vitamin D Assay by Selection of Appropriate Mobile Phase Subhra Bhattacharya and Stephen C. Roemer Thermo Fisher Scientific Global Chemicals, Fair Lawn, NJ, USA AbstrAct Liquid
More informationProtein Analysis using Electrospray Ionization Mass Spectroscopy *
OpenStax-CNX module: m38341 1 Protein Analysis using Electrospray Ionization Mass Spectroscopy * Wilhelm Kienast Andrew R. Barron This work is produced by OpenStax-CNX and licensed under the Creative Commons
More informationMeasuring Lipid Composition LC-MS/MS
Project: Measuring Lipid Composition LC-MS/MS Verification of expected lipid composition in nanomedical controlled release systems by liquid chromatography tandem mass spectrometry AUTHORED BY: DATE: Sven
More informationAn Alternative Approach: Top-Down Bioanalysis of Intact Large Molecules Can this be part of the future? Lecture 8, Page 27
An Alternative Approach: Top-Down Bioanalysis of Intact Large Molecules Can this be part of the future? Lecture 8, Page 27 Top-down HRAM Bioanalysis of Native Proteins/Molecules Relative Abundance 100
More informationIon fragmentation of small molecules in mass spectrometry
Ion fragmentation of small molecules in mass spectrometry Jeevan Prasain jprasain@uab.edu 6-2612 Nomenclature: the main names and acronyms used in mass spectrometry Molecular ion: Ion formed by addition
More informationIon Source. Mass Analyzer. Detector. intensity. mass/charge
Proteomics Informatics Overview of spectrometry (Week 2) Ion Source Analyzer Detector Peptide Fragmentation Ion Source Analyzer 1 Fragmentation Analyzer 2 Detector b y Liquid Chromatography (LC)-MS/MS
More informationSupporting information
Supporting information Figure legends Supplementary Table 1. Specific product ions obtained from fragmentation of lithium adducts in the positive ion mode comparing the different positional isomers of
More informationQuantification of PtdInsP 3 molecular species in cells and tissues by mass spectrometry
Nature Methods Quantification of PtdInsP 3 molecular species in cells and tissues by mass spectrometry Jonathan Clark, Karen E Anderson, Veronique Juvin, Trevor S Smith, Fredrik Karpe, Michael J Wakelam,
More informationComponents of a Mass Spectrometer
Components of a Mass Spectrometer Sample Introduction Inlet GC LC Direct Insertion (Syringe/Probe) Ionization Ion Separation Ion Detection Ion Source EI,CI,,, MALDI Mass Analyzer Under vacuum TOF, Quadrupole,
More informationThe Raptor HILIC-Si Column
The Raptor HILIC-Si Column With Raptor LC columns, Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or core-shell particles) with the resolution
More informationO O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions
Simplifying Qual/Quan Analysis in Discovery DMPK using UPLC and Xevo TQ MS Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION The determination of the drug metabolism
More informationMS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager
MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager Quick Start Guide Step 1. Calibrate the Q-TOF LC/MS for low m/z ratios 2 Step 2. Set up a Flow Injection Analysis (FIA) method for
More informationMass Spectrometry. Actual Instrumentation
Mass Spectrometry Actual Instrumentation August 2017 See also http://www.uni-bielefeld.de/chemie/analytik/ms f additional infmation 1. MALDI TOF MASS SPECTROMETRY ON THE ULTRAFLEX 2 2. ESI MASS SPECTROMETRY
More informationMS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine
Application Note: 346 MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine Gargi Choudhary and Diane Cho, Thermo Fisher Scientific, San Jose, CA Wayne Skinner and
More informationDIRECT EXTRACTION OF BENZODIAZEPINE METABOLITE WITH SUPERCRITICAL FLUID FROM WHOLE BLOOD
DIRECT EXTRACTION OF BENZODIAZEPINE METABOLITE WITH SUPERCRITICAL FLUID FROM WHOLE BLOOD Kenichi TAKAICHI, Shuji SAITOH, Yoshio KUMOOKA, Noriko TSUNODA National Research Institute of Police Science, Chiba,
More informationUptake and Metabolism of Phthalate Esters by Edible Plants
1 Supporting Information for 2 3 Uptake and Metabolism of Phthalate Esters by Edible Plants 4 Jianqiang Sun, Xiaoqin Wu, Jay Gan * 5 6 7 Department of Environmental Sciences, University of California,
More informationDetermination of Aflatoxins in Food by LC/MS/MS. Application. Authors. Abstract. Experimental. Introduction. Food Safety
Determination of Aflatoxins in Food by LC/MS/MS Application Food Safety Authors Masahiko Takino Agilent Technologies 9-1 Takakura-Cho Hachiouji-Shi, Tokyo Japan Toshitsugu Tanaka Kobe Institute of Health
More informationStrengthening Results. Advanced Chromatography with Mass Detection
Strengthening Results Advanced Chromatography with Mass Detection UV Detection Why Not Use UV For Everything? Identification Difficult selectivity in complex matrices Sensitivity Need sufficient molar
More informationMass Spectrometry at the Laboratory of Food Chemistry. Edwin Bakx Laboratory of Food Chemistry Wageningen University
Mass Spectrometry at the Wageningen University Mass Spectrometry at the 3 UPLC/CE - ESI - Ion trap MS systems UPLC Thermo Acella with a Velos or VelosPro CE Beckman PA800 with a Thermo VelosPro 1 UPLC-
More information2013 Waters Corporation 1
High Definition Mass Spectrometry (HDMS) application of ion mobility in oil and petroleum analysis Patrice Lemire Waters Corporation WCTOW Vancouver, May 13, 2013 2013 Waters Corporation 1 Introduction
More informationAnalysis of Pesticides (II) Metribuzin & their metabolites in Rice Jun Yonekubo, Nihon Waters, JAPAN
Waters Alliance LC/MS System Analytical Conditions Chromatograms Mass Spectra Calibration Quantitation Analysis of Pesticides (II) Metribuzin & their metabolites in Rice Jun Yonekubo,, JAPAN Key Words
More informationREDOX PROTEOMICS. Roman Zubarev.
REDOX PROTEOMICS Roman Zubarev Roman.Zubarev@ki.se Physiological Chemistry I, Department for Medical Biochemistry & Biophysics, Karolinska Institutet, Stockholm What is (RedOx) Proteomics? Proteomics -
More informationLCMS-8030 Application Report. Steroids: Testosterone, Progesterone, Estradiol, Ethinylestradiol
LCMS-8030 Application Report Steroids: Testosterone, Progesterone, Estradiol, Ethinylestradiol Summary: Sensitivity was tested for four steroids on the LCMS-8030 triple quadrupole mass spectrometer coupled
More informationANALYTICAL SCALE AGILENT LCMS SYSTEMS OPERATIONAL QUALIFICATION
ANALYTICAL SCALE AGILENT LCMS SYSTEMS OPERATIONAL QUALIFICATION Overview This document describes the test program for qualifying Agilent LCMS systems. The following tables list all MS source-specific OQ
More informationImpurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF
Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF PUSHER TOF DETECTOR ZSPRAY TM Ion Source SAMPLING CONE SKIMMER RF HEXAPOLE RF HEXAPOLE QUADRUPOLE IN NARROW BANDPASS MODE
More informationApplication of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices
Application ote #LCMS-2 esquire series Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices Introduction The simple monitoring
More informationApplication Note # FTMS-46 solarix XR: Analysis of Complex Mixtures
Application Note # FTMS-46 solarix XR: Analysis of Complex Mixtures Introduction Natural organic matter (NOM) as well as crude oil and crude oil fractions are very complex mixtures of organic compounds
More informationThe use of mass spectrometry in lipidomics. Outlines
The use of mass spectrometry in lipidomics Jeevan Prasain jprasain@uab.edu 6-2612 utlines Brief introduction to lipidomics Analytical methodology: MS/MS structure elucidation of phospholipids Phospholipid
More informationRapid Generation of Fatty Acid Methyl Ester Profiles using (Direct Analysis in Real Time) DART- Mass Spectrometry
Rapid Generation of Fatty Acid Methyl Ester Profiles using (Direct Analysis in Real Time) DART- Mass Spectrometry Brian Musselman, Jordan Krechmer, Tim Ng, and Joseph LaPoint IonSense, Inc. 999 Broadway
More informationNew Solvent Grade Targeted for Trace Analysis by UHPLC-MS
New Solvent Grade Targeted for Trace Analysis by UHPLC-MS Subhra Bhattacharya, Deva H. Puranam, and Stephen C. Roemer Thermo Fisher Scientific Fisher Chemical, One Reagent Lane, Fair Lawn, NJ Material
More informationRapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer
Robert Plumb, Michael D. Jones, and Marian Twohig Waters Corporation, Milford, MA, USA INTRODUCTION The detection and characterization of impurities and degradation products of an active pharmaceutical
More informationIonization Methods. Ionization Methods
Ionization Methods Árpád Somogyi Associate Director CCIC, Mass Spectrometry and Proteomics Laboratory OSU August 17, 2015 Ionization Methods Neutral species Charged species Removal/addition of electron(s)
More informationWelcome! Mass Spectrometry meets Cheminformatics WCMC Metabolomics Course 2014 Tobias Kind. Course: Search of MS/MS files with the NIST MS Search GUI
Biology Informatics Chemistry Welcome! Mass Spectrometry meets Cheminformatics WCMC Metabolomics Course 2014 Tobias Kind Course: Search of MS/MS files with the NIST MS Search GUI http://fiehnlab.ucdavis.edu/staff/kind
More informationLC-MS/MS Method for the Determination of Tenofovir from Plasma
LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract
More informationComparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D
Comparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D Julie A. Horner 1, Marta Kozak 1, Subodh Nimkar 1, and August A. Specht 1 1 Thermo Fisher Scientific, San Jose,
More informationJohn Haselden 1, Gordon Dear 1, Jennifer H. Granger 2, and Robert S. Plumb 2. 1GlaxoSmithKline, Ware, UK; 2 Waters Corporation, Milford, MA, USA
Challenges of Polar Compound Analysis Routine LC/MS-based analyses usually rely on using reversed-phase column chemistries (e.g. C 18, C 8, C 4 ) in their LC methodology. However, one of the shortcomings
More informationFat-Soluble Vitamins Analysis on an Agilent ZORBAX Eclipse PAH Polymeric C18 Bonded Column
Fat-Soluble Vitamins Analysis on an Agilent ZORBAX Eclipse PAH Polymeric C8 Bonded Column Application Note Food Authors Rongjie FU Agilent Technologies (Shanghai) Co. Ltd. Ying Lun Road Waigaoqiao Free
More informationComparison of mass spectrometers performances
Comparison of mass spectrometers performances Instrument Mass Mass Sensitivity resolution accuracy Quadrupole 1 x 10 3 0.1 Da* 0.5-1.0 pmol DE-MALDI 2 x 10 4 20 ppm 1-10 fmol peptide 1-5 pmol protein Ion
More informationMass Spectrometry. Mass spectrometer MALDI-TOF ESI/MS/MS. Basic components. Ionization source Mass analyzer Detector
Mass Spectrometry MALDI-TOF ESI/MS/MS Mass spectrometer Basic components Ionization source Mass analyzer Detector 1 Principles of Mass Spectrometry Proteins are separated by mass to charge ratio (limit
More informationThe New 6495 Triple Quadrupole LC/MS
The New 6495 Triple Quadrupole LC/MS Experience A New Level of Confidence Martin Haex Product Specialist MS and Automation 1 Overview of Topics The New 6495 QQQ LC/MS Technology Innovations Quantitation
More informationMass Spectrometry based metabolomics
Mass Spectrometry based metabolomics Metabolomics- A realm of small molecules (
More informationDienes Derivatization MaxSpec Kit
Dienes Derivatization MaxSpec Kit Item No. 601510 www.caymanchem.com Customer Service 800.364.9897 Technical Support 888.526.5351 1180 E. Ellsworth Rd Ann Arbor, MI USA TABLE OF CONTENTS GENERAL INFORMATION
More informationIC-MS Environmental Applications - Water Testing. Application Notebook
IC-MS Environmental Applications - Water Testing Application Notebook Table of Contents Environmental Sample Using IC-MS 3 Environmental Applications: Water Testing Acrylamide in Water 4 Trace Urea in
More informationChapter 3. Structure of Enzymes. Enzyme Engineering
Chapter 3. Structure of Enzymes Enzyme Engineering 3.1 Introduction With purified protein, Determining M r of the protein Determining composition of amino acids and the primary structure Determining the
More informationTHE ROLE OF LABORATORY MEDICINE FOR BIOPASSPORTIZATION IN SPORTS. Dobrin Svinarov Alexander Hospital Medical University of Sofia, Bulgaria
THE ROLE OF LABORATORY MEDICINE FOR BIOPASSPORTIZATION IN SPORTS Dobrin Svinarov Alexander Hospital Medical University of Sofia, Bulgaria SYNOPSIS The flood of new technologies in Lab Medicine Principles
More informationCAMAG TLC-MS INTERFACE
CAMAG TLC-MS INTERFACE 93.1 249.2 40 30 97.1 20 10 250.2 0 200 400 m/z WORLD LEADER IN PLANAR-CHROMATOGRAPHY Identification and elucidation of unknown substances by hyphenation of TLC / HPTLC and MS The
More informationSulfate Radical-Mediated Degradation of Sulfadiazine by CuFeO 2 Rhombohedral Crystal-Catalyzed Peroxymonosulfate: Synergistic Effects and Mechanisms
Supporting Information for Sulfate Radical-Mediated Degradation of Sulfadiazine by CuFeO 2 Rhombohedral Crystal-Catalyzed Peroxymonosulfate: Synergistic Effects and Mechanisms Submitted by Yong Feng, Deli
More informationDetermination of Selected Illegal Drugs and its Important Metabolites in Waste Water by Large Volume Direct Injection HPLC-MS/MS
Determination of Selected Illegal Drugs and its Important Metabolites in Waste Water by Large Volume Direct Injection HPLC-MS/MS Jean-Daniel Berset 1 and André Schreiber 2 1 Water and Soil Protection Laboratory,
More informationA General Unknown Screening for Drugs and Toxic Compounds in Human Serum. Thesis
A General Unknown Screening for Drugs and Toxic Compounds in Human Serum Thesis Submitted to the Faculty of Natural Sciences of the University of Basel, Switzerland for the Fulfilment of the Requirements
More informationTime (min) Supplementary Figure 1: Gas decomposition products of irradiated DMC.
200000 C 2 CH 3 CH 3 DMC 180000 160000 140000 Intensity 120000 100000 80000 60000 40000 C 2 H 6 CH 3 CH 2 CH 3 CH 3 CCH 3 EMC DEC 20000 C 3 H 8 HCCH 3 5 10 15 20 25 Time (min) Supplementary Figure 1: Gas
More informationMoving from targeted towards non-targeted approaches
Gesundheitsdirektion Moving from targeted towards non-targeted approaches Anton Kaufmann Official Food Control Authority of the Canton of Zurich () Switzerland 2 Overview I From single residue to multi
More informationCONTENT. i iv ix. SVKM s NMIMS, School of Pharmacy and Technology Management
CONTENT Chapter No. Title Page No. Abbreviations List of Figures List of Tables 1 Introduction 1 1.1 Practical aspects 4 1.2 Stability-indicating assay method (SIAM) 5 1.3 Regulatory aspects 6 1.4 Techniques
More informationRobust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS
TECHNICAL NOTE 21882 Robust extraction, separation, and quantitation of structural isomer steroids human plasma by SPE-UHPLC-MS/MS Authors Jon Bardsley 1, Kean Woodmansey 1, and Stacy Tremintin 2 1 Thermo
More informationUltra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification
22 SEPARATION SCIENCE REDEFINED MAY 2005 Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification In the drug discovery process the detection and
More informationMetabolite identification in metabolomics: Database and interpretation of MSMS spectra
Metabolite identification in metabolomics: Database and interpretation of MSMS spectra Jeevan K. Prasain, PhD Department of Pharmacology and Toxicology, UAB jprasain@uab.edu utline Introduction Putative
More informationConsiderations of the use of Triple Quadrupoles or Ion Traps in Quantitative Applications
Considerations of the use of Triple Quadrupoles or Ion Traps in Quantitative Applications Triple Stage Quadrupole API MS / MS Full Scan Products / - IONS AND NEUTRALS FORMED IN API SOURCE Q0 LENS TRANSPORTS
More informationImproved method for the quantification of lysophospholipids including enol ether
Supplemental Material Improved method for the quantification of lysophospholipids including enol ether species by liquid chromatography-tandem mass spectrometry James G. Bollinger *, Hiromi Ii*, Martin
More information