Ultrasound Velocity to Measure Fillet Fat Content

Size: px
Start display at page:

Download "Ultrasound Velocity to Measure Fillet Fat Content"

Transcription

1 Ultrasound Velocity to Measure Fillet Fat Content Abstract The objective of this research is to develop a reliable non invasive method to measure fat content in fillet using ultrasound A-Mode scan. The results of the fat measurement from this non invasive method were then compared to the results of fat measurement using a proven method. The Soxhlet method is a standard fat measurement procedure recommended by the Association of Official Analytical Chemist (AOAC). The samples used in this investigation are chicken, meat and fish fillets. The experimental results showed that there is correlation between fat content and the measured ultrasound velocity travelled in the sample. This indicates that fat measurement using the ultrasound A-Mode scan technique can be used to determine fat content in fillet with reasonable accuracy by using accurate tools for the measurement process and increasing the data acquisition during the experiment. Keywords Fillet, Ultrasound velocity, Fat content I. INTRODUCTION Fat is very important to our body but consuming it exceedingly, will contribute to health complication such as heart disease, high blood pressure and obesity [1]. One of the major fat sources is meat either chicken, beef or fish. However most of these methods, for example the Soxhlet Method, cause the destruction of the food itself. A number of researchers have attempted to develop non invasive techniques to measure fat in food. For example, Buniyamin [2, 3], used near infrared Radiation (NIR) technique to measure fat content in food products such as fish fillets and burgers with some success. The research presented in this paper attempts to develop a reliable non invasive method to measure fat in meat type fillet using ultrasound. A study by Sriyani Jayasooriya [4] stated that conventional application of ultrasound such as medical imaging; cleaning and measuring fat depth of carcasses are well established. That statement is well proved by a lot of researchers and application nowadays. Ultrasound velocity measurement itself is not new since there is a research that uses ultrasound technique for fluids characterization [7]. R.A. Shannon [6] in his research, used ultrasound velocity as a tool to measure and determine fat content in salmon fillet muscle. He used Panametric 500PR pulser-receiver to produce ultrasonic pulse and two 2.25 MHz single-element transducer to transmit and receive ultrasonic pulse. 12 numbers of samples from two difference supplier is used in her study. The result found that ultrasound velocity in a sample can be affected by the non-constant density due to the in-homogeneities of fat content in salmon muscle [6]. The research presented in this paper, attempts to measure fat in a natural non-homogenous substance; that is meat fillet from various type of animal; chicken, beef and fish. The sample is naturally nonhomogenous due to natural variations in the tissue itself. II. METHODS AND SAMPLE The meat fillet fat was first measured using the ultrasound A-Mode Scan method and then using the standard Soxhlet method. The Soxhlet method is a traditional method for the analysis of fat that was developed by a German chemist Franz von Soxhlet in 1879 [5]. The results from the Soxhlet measurement were used to validate the result from the ultrasound velocity measurement method. Ten (10) pieces of meat fillet each from chicken, beef and fish from a Malaysian supplier was used. The fat content of the meat fillet was measured at room temperatures. Since the samples were frozen during storage, they were left for thaw before being used for experiment. Samples reach the room temperature defined as 27 0 C after 5 hours of thawing process. Water content in frozen state will give a slight effect on the ultrasound velocity. It has been shown that ultrasound velocity increase approximately 8% after the sample is thawed [8]. Figure 1 shows the samples exposed to room temperature. 69

2 Figure 2: Fat measurement rig C B A Figure 1: Chicken, beef and fish fillet III. ULTRASOUND MEASUREMENT METHOD The fat measurement rig for velocity measurement experiment is shown in Figure 2. The rig is used to positioning the sample between the ultrasound transmitter and receiver ultrasound. It can hold the sample with maximum thickness of 60mm. Ultrasound Echoscope GAMPT-Scan is used to generate ultrasound pulse. 2MHz ultrasound transmitter is used to transmit the ultrasound wave and 4MHz receiver for receiving transmitted ultrasound wave. To increase the sound conductivity, ultrasound gel is applied to the sample before measurement is start. Computer was used to log the data collected. The complete connection for experiment is shown in Figure 3. With label, A is fat measurement rig, B is Ultrasound Echoscope GAMPT-Scan and C is the computer. Figure 3: Connection for ultrasound velocity measurement method The set-up was built to enable the ultrasonic pulse to enter and pass through the filet. Theoretically, ultrasonic pulse velocity travel through a medium depends on the density of the medium. Medium density is majorly influenced by its meat, fat and water content assuming that no bones exist in the fillet that is measured. For this experiment, it is assumed that the water content for all samples is same after undergoing the same thawing process and that only fat content will vary in the samples. The receiver will detect the ultrasonic pulse travelled through the samples. The time-of-flight of ultrasonic pulse is recorded to measure the ultrasound velocity in the samples. Equation {1} is used to measure the velocity. {1} 70

3 The ultrasound velocity for each sample, was measured 5 times, at 5 difference locations and was then averaged [4]. IV. VALIDATION The fat in all the samples were then extracted and measured using the Soxhlet method to investigate the accuracy of the fat detection using the ultrasound velocity measurement method. In the Soxhlet method, the samples were first dried, grinded, weighed; and the fat was then collected using a chemical reactant apparatus setup as in Figure 4. Fat percentage is calculated by using equation {2}. {2} using linear regression line, the value of coefficient of determination, R 2 was obtained. In order to find the correlation between percentage of fat and ultrasound velocity ms -1, the value of the correlation coefficient, R was first determined. Table 1 shows the rule of thumb that was used, where the relationship between both parameters was determined based on the value of R. The value of R shows how much the point fits the regression line. The closer to 1.0, the better fits the regression line and thus shows that the relationship between both parameters is strong. TABLE I RULE OF THUMB FOR CORRELATION COEFFICIENT. Value of correlation coefficient, R Strength of relationship -1.0 to -0.5 or 0.5 to 1.0 Strong -0.5 to -0.3 or 0.3 to 0.5 Moderate -0.3 to -0.1 or 0.1 to 0.3 Weak -0.1 to 0.1 None or very weak A. Results for Chicken fillet samples. Figure 5 shows the ultrasound velocity versus method for Chicken fillet. Figure 5: Graph of ms -1 versus %fat for Chicken fillet. Figure 4: Soxhlet Process V. RESULTS From the graph, there is the trend of decreasing in ultrasound velocity in increasing of fat content. By using linear regression, the value for R 2 is obtained. All data from ultrasound velocity measurement method were plotted in graphs that plot ultrasound velocity, ms -1 versus percentage of fat (%). By 71

4 By using the rule of thumb, with r=0.411 and n= 10, there is moderate linear correlation between ultrasound velocity and fat percentages in chicken fillet. B. Results for beef fillet samples. Figure 6 shows the ultrasound velocity versus method for Beef fillet. With value of r= and n=10, the correlation between ultrasound velocity and fat content in fish fillet is weak. Figure 7: Graph of ms -1 versus %fat for Fish fillet. VI. DISCUSSION AND CONCLUSION Figure 6: Graph of ms -1 versus %fat for Beef fillet. From the graph, there is the trend of increasing in ultrasound velocity in increasing of fat content. This graph slightly does not satisfy the theory. For value R 2 = 0.079, With value of r= and n= 10, the graph did not satisfy the theory and showed weak correlation between ultrasound velocity and fat percentages in meat fillet. C. Results for Fish fillet samples. Figure 7 shows the ultrasound velocity versus method for Fish fillet. From the graph, there is the trend of increasing in ultrasound velocity in increasing of fat content. This graph satisfies the theory. For value R 2 = 0.049, Result from the experiment can be said to be slightly inaccurate due to several measurement weaknesses during the experiment. The measurement weaknesses mention here are tools for thickness measuring and in-homogeneities of fat concentration in a sample. Tools used for thickness measurement is a standard ruler with only 0.1cm dimension. Since the ultrasound velocity in sample is higher than 1000m/s, more accurate tools is needed to measure the sample thickness. This problem can be solved by using micrometer. Inhomogeneities fat content will affect the measurement accuracy since variation in fat content in a sample will affect the ultrasound velocity. This problem can be solved by using more samples with more reading taken from each sample. This paper showed there is a trend of decreasing ultrasound velocity with increasing fat content in the sample. This trend can be seen on chicken fillet and fish fillet result. Although the results obtained satisfy the theory, the correlations between two variables are moderates and weak. For meat fillet, result obtained did not satisfy the theory. From early observation and analysis, it due to in-homogeneities of fat concentration is sample and inappropriate tools used to measure sample thickness. This phenomenon and action can contribute to the error during the experiment. Illustration below show how weakness in fat measurement occurs due to in-homogeneities of fat concentration in the sample. As shown in Figure 8, 72

5 on the fish fillet picture, the mark x indicates the position with high fat concentration and the circle marks the place where the transducer is placed. ACKNOWLEDGMENT The authors gratefully acknowledge and thank University Teknologi Mara (UiTM) for the Research Intensive Faculty Grant. In addition, the authors would also like to thank the medical laboratory technician, Mr. Mohamad Azhar Johari and the Food Technology Laboratory assistant, Mrs. Nor Suhadah Mohammad Samri for their support throughout this project. REFERENCES Figure 8: Fish fillet As shown, the transducer is placed at different 5 points and thus do not fully represent (or accurately) the fat content in the fish fillet as for this type of fish, the fat is concentrated at the edges. This will contribute the error when compared with Soxhlet method result. This weakness also occurs in measurement for meat fillet and chicken fillet. In order to minimize this weakness, more reading should be taken from the sample. The effect of variation in fat concentration in sample also can be minimized if a large number of samples used Proper tool for measuring sample thickness is necessary. Small error in measuring sample thickness will give huge effect to the ultrasound velocity since the time-of-flight is in s unit. Tools with high dimension and accuracy such as micrometer should be used. [1] CHOLESTEROLDATABASE.COM. Saturated Fat Source: List of Food High in Saturated Fat and Total Fatty Acids (beef, pork, chicken). Internet: [December 1, 2011] [2] Norlida Buniyamin, Ringgau D., Mohamad Z., Murat Z. H., Non- Destructive Fish Fat Detection Using Infrared Sensor in 2011 International Conference on Food Engineering and Biotechnology (ICFEB 2011), Bangkok, Thailand. Vol. 9, pp 33-37, 7th 9th May [3] Norlida Buniyamin, M.A. Mohd Shari, M.H. Abdul Halim, R. Sam, Using Infrared Radiation to Measure Burger Fat Content, Proceedings of the 2012 International Conference on System Engineering and Technology (2012 ICSET), September 11-12, 2012, Bandung, Indonesia. [4] Sriyani Jayasooriya, Dr. Bhesh Bhandari, Dr. Peter Torley, Dr. Bruce D Arcy. Ultrasound in Meat Processing. Internet: f, [December 2, 2011] [5] M. Hazwan Abdul Halim, Ultrasound velocity measurement to determine fat content in chicken, beef and fish fillet, in Faculty of Electrical Engineering, Thesis, Bachelor of Elec. Engineering. Shah Alam: University Teknologi MARA (UiTM), 2007, pp. 60. [6] R.A. Shannon, P.J. Probert-Smith, J.Lines, F. Mayia. Ultrasound Velocity Measurement to Determine Lipid Content in Salmon Muscle: the effect of mysepta. January 8, 2004 [ November 24, 2010] [7] Malcolm J.W. Povey. Ultrasound Techniques for Fluids Characterization, Internet: 003#PDFExcerpt, October 18, 2007 [December 5, 2011] [8] REZA GHAEDIAN, ERIC ANDREW DECKER, DAVID JULIAN McCLEMENTS. Use of Ultrasound to Determine Cod Fillet Composition. Journal of Food Science, Internet: July 20, 2006 [December 5, 2011] 73

Ultrasound Measurements and Non-destructive Testing Educational Laboratory

Ultrasound Measurements and Non-destructive Testing Educational Laboratory Session 3548 Ultrasound Measurements and Non-destructive Testing Educational Laboratory Vladimir Genis, Horacio Sosa Goodwin College of Professional Studies, Drexel University, Philadelphia, 19104 Emil

More information

An Overview of Ultrasound Testing For Lesion Detection in Human Kidney

An Overview of Ultrasound Testing For Lesion Detection in Human Kidney Journal of Tomography System & Sensors Application Vol.1, Issue 1, June 2018 An Overview of Ultrasound Testing For Lesion Detection in Human Kidney Aina Fadhilah Abd Rahim 1, Zawin Najah Abd Halim 1, Jaysuman

More information

1. Fig. 1 shows data for the intensity of a parallel beam of X-rays after penetration through varying thicknesses of a material

1. Fig. 1 shows data for the intensity of a parallel beam of X-rays after penetration through varying thicknesses of a material 1. Fig. 1 shows data for the intensity of a parallel beam of X-rays after penetration through varying thicknesses of a material. intensity / MW m 2 thickness / mm 0.91 0.40 0.69 0.80 0.52 1.20 0.40 1.60

More information

Non-Destructive Inspection of Composite Wrapped Thick-Wall Cylinders

Non-Destructive Inspection of Composite Wrapped Thick-Wall Cylinders Non-Destructive Inspection of Composite Wrapped Thick-Wall Cylinders Jikai Du, John Feldhacker, Christopher Jerred and Fereidoon Delfanian May 17-19, 2010 Joint Armaments Conference, Exhibition and Firing

More information

Flaw Assessment Using Shear wave Phased array Ultrasonic Transducer

Flaw Assessment Using Shear wave Phased array Ultrasonic Transducer 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Flaw Assessment Using Shear wave Phased array Ultrasonic Transducer Byungsik YOON AUTHOR 1, Hee-Jong LEE CO-AUTHOR

More information

The table below shows the density and velocity of waves in two different substances. Density / kg m 3 Velocity / m s 1

The table below shows the density and velocity of waves in two different substances. Density / kg m 3 Velocity / m s 1 Q1.(a) When ultrasound is incident at an interface between two different media some energy is transmitted and some is reflected. The ratio of the reflected energy intensity I r to the incident energy intensity

More information

Ultrasonic Testing of Composite Structures

Ultrasonic Testing of Composite Structures I. Introduction Ultrasonic Testing of Composite Structures This section of this work defines ultrasound basic concepts and Ultrasonic Technique. It describes the details of how ultrasonic testing works,

More information

Ultrasound in Medicine

Ultrasound in Medicine Ultrasound in Medicine Experimental Equipment for Medical Education Universities Colleges Medical Schools Medical and Med-Technical Training Education can befun! WELCOME TO GAMPT Devices and accessories

More information

Real Time 2D Ultrasound Camera Imaging: A Higher Resolution Option to Phased Array Bob Lasser Randy Scheib Imperium, Inc.

Real Time 2D Ultrasound Camera Imaging: A Higher Resolution Option to Phased Array Bob Lasser Randy Scheib Imperium, Inc. Real Time 2D Ultrasound Camera Imaging: A Higher Resolution Option to Phased Array Bob Lasser Randy Scheib Imperium, Inc. Beltsville Imperium Involved in NDT since 1996 Sole provider of UT camera technology

More information

Evaluation of the Quality of Thick Fibre Composites Using Immersion and Air- Coupled Ultrasonic Techniques

Evaluation of the Quality of Thick Fibre Composites Using Immersion and Air- Coupled Ultrasonic Techniques ECNDT 2006 - We.1.6.4 Evaluation of the Quality of Thick Fibre Composites Using Immersion and Air- Coupled Ultrasonic Techniques Kaj K. BORUM, Risø National Laboratory, Materials Research Department, Roskilde,

More information

Controlled Cryogenic Ablation Using Ultrasonic Sensing

Controlled Cryogenic Ablation Using Ultrasonic Sensing (a) SENSORDEVICES 2015 : The Sixth International Conference on Sensor Device Technologies and Applications Controlled Cryogenic Ablation Using Ultrasonic Sensing Assaf Sharon Robots and BioMedical Micro

More information

Linear Ultrasonic Wave Propagation in Biological Tissues

Linear Ultrasonic Wave Propagation in Biological Tissues Indian Journal of Biomechanics: Special Issue (NCBM 7-8 March 29) Linear Ultrasonic Wave Propagation in Biological Tissues Narendra D Londhe R. S. Anand 2, 2 Electrical Engineering Department, IIT Roorkee,

More information

Diploma of Medical Ultrasonography (DMU) Physical Principles of Ultrasound and Instrumentation Syllabus

Diploma of Medical Ultrasonography (DMU) Physical Principles of Ultrasound and Instrumentation Syllabus Diploma of Medical Ultrasonography (DMU) Physical Principles of Ultrasound and Instrumentation Syllabus Page 1 of 7 11/18 Candidates are expected to cover all of the content of this syllabus when preparing

More information

Sensors & Transducers 2015 by IFSA Publishing, S. L.

Sensors & Transducers 2015 by IFSA Publishing, S. L. Sensors & Transducers 2015 by IFSA Publishing, S. L. http://www.sensorsportal.com Advanced Controlled Cryogenic Ablation Using Ultrasonic Sensing System * Assaf Sharon, Gabor Kosa Robots and BioMedical

More information

ULTRASOUND. OB/Gyn (Core) Ultrasound PIEZOELECTRIC EFFECT. Principles of Ultrasound Physics and Instrumentation. Nathan Pinkney, BS, CDOS

ULTRASOUND. OB/Gyn (Core) Ultrasound PIEZOELECTRIC EFFECT. Principles of Ultrasound Physics and Instrumentation. Nathan Pinkney, BS, CDOS 1 OB/Gyn (Core) Ultrasound Principles of Ultrasound Physics and Instrumentation Nathan Pinkney, BS, CDOS Philadelphia College of Osteopathic Medicine 2016 ULTRASOUND CATEGORIES OF SOUND INFRASOUND = below

More information

ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah

ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah ULTRASOUND IMAGING EE 472 F2018 Prof. Yasser Mostafa Kadah www.k-space.org Recommended Textbook Diagnostic Ultrasound: Physics and Equipment, 2nd ed., by Peter R. Hoskins (Editor), Kevin Martin (Editor),

More information

INSPECTION THROUGH AN OVERLAY REPAIR WITH A SMART FLEXIBLE ARRAY PROBE.

INSPECTION THROUGH AN OVERLAY REPAIR WITH A SMART FLEXIBLE ARRAY PROBE. INSPECTION THROUGH AN OVERLAY REPAIR WITH A SMART FLEXIBLE ARRAY PROBE. Ph. Brédif (*), G. Selby (**), S. Mahaut (*), O. Casula (*) (*) CEA/DRT, Saclay, France (**) EPRI, USA 1. ABSTRACT Contact inspection

More information

Pipeline Technology Conference 2007

Pipeline Technology Conference 2007 The Complete Solution: Combined Crack and Metal Loss Detection Tool using Phased Array Technology By A. Hugger, J. Franz, H. Charbon, R. Bauernschmitt, M. Tschuch, K.-H. Käshammer, I. Lachtchouk, J. Ehrhardt.

More information

ULTRASONIC ARRAY APPROACH FOR THE EVALUATION OF ELECTROFUSION JOINTS OF POLYETHYLENE GAS PIPING

ULTRASONIC ARRAY APPROACH FOR THE EVALUATION OF ELECTROFUSION JOINTS OF POLYETHYLENE GAS PIPING ULTRASONIC ARRAY APPROACH FOR THE EVALUATION OF ELECTROFUSION JOINTS OF POLYETHYLENE GAS PIPING H. J. Shin 1, Y. H. Jang 1, J. R. Kwan 2, H. D. Lee 3 1 INDE System Co., Ltd., Suwon, Kyunggi-do, 440-746,

More information

Principles of Ultrasound. Cara C. Prideaux, M.D. University of Utah PM&R Sports Medicine Fellow March 14, 2012

Principles of Ultrasound. Cara C. Prideaux, M.D. University of Utah PM&R Sports Medicine Fellow March 14, 2012 Principles of Ultrasound Cara C. Prideaux, M.D. University of Utah PM&R Sports Medicine Fellow March 14, 2012 None Disclosures Outline Introduction Benefits and Limitations of US Ultrasound (US) Physics

More information

Feng Xiujuan National Institute of Metrology (NIM),China

Feng Xiujuan National Institute of Metrology (NIM),China The acoustic calibration service in transportation at NIM Feng Xiujuan National Institute of Metrology (NIM),China 1. Calibration requirements 2. Calibration service at NIM 2.1 Microphone 2.2 Ultrasonic

More information

Intrinsically Safe Ultrasonic Testers: How important are they?

Intrinsically Safe Ultrasonic Testers: How important are they? Intrinsically Safe Ultrasonic Testers: How important are they? Introduction The use of ultrasonic devices for non-destructive testing (NDT) has become more common in recent years as equipment has increased

More information

Diagnostic Ultrasound. Sutiporn Khampunnip, M.D.

Diagnostic Ultrasound. Sutiporn Khampunnip, M.D. Diagnostic Ultrasound Sutiporn Khampunnip, M.D. Definition of Ultrasound Ultrasound is simply sound waves, like audible sound. High-frequency sound and refers to mechanical vibrations above 20 khz. Human

More information

Ultrasonic Thickness Procedure Pulse-Echo Thickness Gage TABLE OF CONTENTS. 1.0 Introduction Reference Documents Summary of Practice 2

Ultrasonic Thickness Procedure Pulse-Echo Thickness Gage TABLE OF CONTENTS. 1.0 Introduction Reference Documents Summary of Practice 2 Page: 1 of 6 TABLE OF CONTENTS SECTION PAGE NO. 1.0 Introduction 2 2.0 Reference Documents 2 3.0 Summary of Practice 2 4.0 Significance & Use 3 5.0 Apparatus 3 6.0 Calibration & Adjustment of Apparatus

More information

Performance of phased array and conventional ultrasonic probes on the new ISO reference block

Performance of phased array and conventional ultrasonic probes on the new ISO reference block Performance of phased array and conventional ultrasonic probes on the new ISO 19675 reference block C. Udell, D. Chai 1 and F. Gattiker Proceq S.A., Ringstrasse 2, Schwerzenbach, Switzerland. More info

More information

Q1. The diagram shows an ultrasound monitor being used to scan a fetus.

Q1. The diagram shows an ultrasound monitor being used to scan a fetus. Q1. The diagram shows an ultrasound monitor being used to scan a fetus. The table shows the velocity of ultrasound waves in different tissues of the fetus. Tissue Amniotic fluid (liquid surrounding fetus)

More information

4.17. RESEARCHING MODELS WITH AN ULTRASONIC ECHOSCOPE

4.17. RESEARCHING MODELS WITH AN ULTRASONIC ECHOSCOPE 4.17. RESEARCHING MODELS WITH AN ULTRASONIC ECHOSCOPE Purpose of experiment Determine the main characteristics of ultrasound waves, and the distances and positions of models using an ultrasonic echoscope.

More information

ESTIMATION OF LAMB CARCASS COMPOSITION USING REAL-TIME ULTRASOUND. F. Pajor - P. Póti* - Láczó E. - J. Tőzsér

ESTIMATION OF LAMB CARCASS COMPOSITION USING REAL-TIME ULTRASOUND. F. Pajor - P. Póti* - Láczó E. - J. Tőzsér ABSTRACT ESTIMATION OF LAMB CARCASS COMPOSITION USING REAL-TIME ULTRASOUND F. Pajor - P. Póti* - Láczó E. - J. Tőzsér S1.25 Szent István University, Faculty of Agricultural and Environmental Sciences,

More information

Predicting Tenderness in Beef Carcasses by Combining Ultrasound and Mechanical Techniques

Predicting Tenderness in Beef Carcasses by Combining Ultrasound and Mechanical Techniques Predicting Tenderness in Beef Carcasses by Combining Ultrasound and Mechanical Techniques A.S. Leaflet R1333 Gene H. Rouse, professor of animal science, Doyle Wilson, professor of animal science, Mehmet

More information

The Evolution and Benefits of Phased Array Technology for the Every Day Inspector

The Evolution and Benefits of Phased Array Technology for the Every Day Inspector ECNDT 2006 - Poster 198 The Evolution and Benefits of Phased Array Technology for the Every Day Inspector Dan KASS, Tom NELLIGAN, and Erich HENJES Olympus NDT, Waltham, USA Abstract. Phased arrays were

More information

Development of NDT Based Electronic System for measurement of ultrasonic Parameter of Coal Sample

Development of NDT Based Electronic System for measurement of ultrasonic Parameter of Coal Sample Development of NDT Based Electronic System for measurement of ultrasonic Parameter of Coal Sample Dipalee.M.KATE, Nitin.K.CHOUDHARI, Archana.R.CHOUDHARI Department of Electronics and Communication, Priyadarshini

More information

Routine analysis for fish farming and processing

Routine analysis for fish farming and processing Routine analysis for fish farming and processing FAT P R O T E I N M O I S T U R E A Q U E O U S S A LT Dedicated Analytical Solutions Contents 1. Introduction: typical fish processing applications 2.

More information

Latest Trends in Circuits, Control and Signal Processing

Latest Trends in Circuits, Control and Signal Processing Bone Fracture Evaluation Using A-Mode Ultrasound *ALWIN ARUL ALEXANDER, **MAHEZA IRNA MOHAMAD SALIM, *SALLEHUDDIN IBRAHIM AND **EKO SUPRIYANTO. *Faculty of Electrical Engineering **Faculty of Biosciences

More information

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System R. K. Saha, S. Karmakar, S. Saha, M. Roy, S. Sarkar and S.K. Sen Microelectronics Division, Saha Institute of

More information

Development of an Electronic Glove with Voice Output for Finger Posture Recognition

Development of an Electronic Glove with Voice Output for Finger Posture Recognition Development of an Electronic Glove with Voice Output for Finger Posture Recognition F. Wong*, E. H. Loh, P. Y. Lim, R. R. Porle, R. Chin, K. Teo and K. A. Mohamad Faculty of Engineering, Universiti Malaysia

More information

CHARACTERIZATION OF ANNULAR ARRAY TRANSDUCER

CHARACTERIZATION OF ANNULAR ARRAY TRANSDUCER Analele Universităţii de Vest din Timişoara Vol. LV, 2011 Seria Fizică CHARACTERIZATION OF ANNULAR ARRAY TRANSDUCER Luminita Moraru 1, Laura Onose 1, 2, Ana-Maria Chiselev 1 1 Dunărea de Jos University

More information

Descriptions of NDT Projects Fall 2004 October 31, 2004

Descriptions of NDT Projects Fall 2004 October 31, 2004 Descriptions of NDT Projects Fall 2004 October 31, 2004 Introduction There are two separate NDT labs in Magister: ULTRA for ultrasound and EDDY for eddy current. Both labs are equipped with mechanical

More information

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion Jason Silver August 26, 2009 Presentation Outline Introduction Thesis Objectives Mathematical Model and Principles Methods

More information

Penetration Depth of 635 nm Laser Light Into the Biological Tissue

Penetration Depth of 635 nm Laser Light Into the Biological Tissue 2017 Published in 5th International Symposium on Innovative Technologies in Engineering and Science 29-30 September 2017 (ISITES2017 Baku - Azerbaijan) Penetration Depth of 635 nm Laser Light Into the

More information

Numerical Modelling of Ultrasonic Phased Array Transducers and Their Application

Numerical Modelling of Ultrasonic Phased Array Transducers and Their Application ECNDT 2006 - Mo.2.7.5 Numerical Modelling of Ultrasonic Phased Array Transducers and Their Application Prashanth Kumar CHINTA, René MARKLEIN, University of Kassel, Department of Electrical Engineering

More information

The Physics of Ultrasound. The Physics of Ultrasound. Claus G. Roehrborn. Professor and Chairman. Ultrasound Physics

The Physics of Ultrasound. The Physics of Ultrasound. Claus G. Roehrborn. Professor and Chairman. Ultrasound Physics The Physics of Ultrasound Pipe Organ 10-8000 Emission Dog 452-1080 Man 85-1100 Spectrum Bat 10,000-120,000 Porpoise 7000-120,000 Claus G. Roehrborn Professor and Chairman 10 20 Cycles per second Reception

More information

Meat technology information sheet

Meat technology information sheet MEAT TECHNOLOGY INFORMATION SHEET Cutting edge technology for the meat processing industry Meat technology information sheet January 2006 A guide to calibration and verification of accuracy for instruments

More information

1.4 - Linear Regression and MS Excel

1.4 - Linear Regression and MS Excel 1.4 - Linear Regression and MS Excel Regression is an analytic technique for determining the relationship between a dependent variable and an independent variable. When the two variables have a linear

More information

Lesson 03: Sound Wave Propagation and Reflection. This lesson contains 15 slides plus 14 multiple-choice questions.

Lesson 03: Sound Wave Propagation and Reflection. This lesson contains 15 slides plus 14 multiple-choice questions. Lesson 03: Sound Wave Propagation and Reflection This lesson contains 15 slides plus 14 multiple-choice questions. Accompanying text for the slides in this lesson can be found on pages 8 through 14 in

More information

APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS

APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS Jeffrey P. Milligan, Daniel T. Peters, Structural Integrity Associates, Inc., USA Many advances in Non-Destructive Examination

More information

4.17. RESEARCHING MODELS WITH AN ULTRASONIC ECHOSCOPE

4.17. RESEARCHING MODELS WITH AN ULTRASONIC ECHOSCOPE 4.17. RESEARCHING MODELS WITH AN ULTRASONIC ECHOSCOPE Purpose of experiment Determine the main characteristics of ultrasound waves, and the distances and positions of models using an ultrasonic echoscope.

More information

HiFFUT A New Class of Transducer

HiFFUT A New Class of Transducer HiFFUT A New Class of Transducer Kick-Off Meeting Dr Andrew Feeney, Postdoctoral Research Fellow My Background I obtained a Master s degree in Mechanical Engineering from the University of Glasgow in 2010

More information

Basic Ultrasound Physics Board Review Questions

Basic Ultrasound Physics Board Review Questions Basic Ultrasound Physics Board Review Questions Sidney K. Edelman, PhD ESP Ultrasound The Woodlands, TX Question 1 What is the wavelength of 2 MHz sound in soft tissue? 1. 1.54 mm 2. 0.75 mm 3. 0.75 cm

More information

Evaluation of the Magnitude of Ractopamine Treatment Biases When Fat- Free Lean Mass is Predicted by Commonly Used Equations

Evaluation of the Magnitude of Ractopamine Treatment Biases When Fat- Free Lean Mass is Predicted by Commonly Used Equations Evaluation of the Magnitude of Ractopamine Treatment Biases When Fat- Introduction Free Lean Mass is Predicted by Commonly Used Equations A. P. Schinckel, C. T. Herr, B. T. Richert, and M. E. Einstein

More information

Stress Wave Focusing Transducers

Stress Wave Focusing Transducers UCRL-K-130697 PREPRINT Stress Wave Focusing Transducers Steven R. Visuri, Richard A. London, Luiz Da Silva This paper was prepared for submittal to Optical Society of America, Spring Topical Meetings Orlando,

More information

EXPERIMENTS WITH BLOOD PRESSURE MONITORING USING ECG AND PPG

EXPERIMENTS WITH BLOOD PRESSURE MONITORING USING ECG AND PPG EXPERIMENTS WITH BLOOD PRESSURE MONITORING USING ECG AND D. Špulák 1, R. Čmejla 1, V. Fabián 2 Czech Technical University in Prague, Faculty of Electrical Engineering, 1 Department of Circuit Theory 2

More information

Case Study. Complex Components Demand Innovative Ultrasound Solution

Case Study. Complex Components Demand Innovative Ultrasound Solution Complex Components Demand Innovative Ultrasound Solution Critical components in the aerospace and defense industries, such as engine housings, wings and control surfaces, undergo rigorous testing to ensure

More information

Introduction to Nondestructive Testing

Introduction to Nondestructive Testing Introduction to Nondestructive Testing Outline Introduction to NDT Overview of Six Most Common NDT Methods Selected Applications Definition of NDT The use of noninvasive techniques to determine the integrity

More information

MOTION ANALYSIS OF A LOW COST CUSTOMIZED A-SCAN NON DESTRUCTIVE TESTING UNIT. M.N. M. Zukri and E. A. Bakar

MOTION ANALYSIS OF A LOW COST CUSTOMIZED A-SCAN NON DESTRUCTIVE TESTING UNIT. M.N. M. Zukri and E. A. Bakar MOTION ANALYSIS OF A LOW COST CUSTOMIZED A-SCAN NON DESTRUCTIVE TESTING UNIT M.N. M. Zukri and E. A. Bakar 1 School of Aerospace Engineering, Universiti Sains Malaysia, * Email: meelmi@usm.my ABSTRACT

More information

The study of microwave heating on proximate composition in fish fillets and balls

The study of microwave heating on proximate composition in fish fillets and balls 2017; 6(9): 117-112 ISSN (E): 2277-7695 ISSN (P): 2349-8242 NAAS Rating 2017: 5.03 TPI 2017; 6(9): 117-112 2017 TPI www.thepharmajournal.com Received: 26-07-2017 Accepted: 27-08-2017 Valentina Chauhan

More information

UNIVERSITI TEKNOLOGI MARA

UNIVERSITI TEKNOLOGI MARA UNIVERSITI TEKNOLOGI MARA THE DEVELOPMENT OF A FINANCIAL MODEL TO PREDICT BUSINESS PERFORMANCE OF IBS CONSTRUCTION COMPANY BASED ON SELECTED FINANCIAL RATIOS NORAZUANIZA BT MOHD YUNUS Thesis submitted

More information

Ultrasound. Principles of Medical Imaging. Contents. Prof. Dr. Philippe Cattin. MIAC, University of Basel. Oct 17th, 2016

Ultrasound. Principles of Medical Imaging. Contents. Prof. Dr. Philippe Cattin. MIAC, University of Basel. Oct 17th, 2016 Ultrasound Principles of Medical Imaging Prof. Dr. Philippe Cattin MIAC, University of Basel Contents Abstract 1 Image Generation Echography A-Mode B-Mode M-Mode 2.5D Ultrasound 3D Ultrasound 4D Ultrasound

More information

1. SCOPE ELIGIBILITY EXAMINATION CONTENT RENEWAL & RECERTIFICATION PROCEDURE ESSENTIAL READING...

1. SCOPE ELIGIBILITY EXAMINATION CONTENT RENEWAL & RECERTIFICATION PROCEDURE ESSENTIAL READING... Certification Services Division Newton Building, St George s Avenue Northampton, NN2 6JB United Kingdom Tel: +44(0)1604-893-811. Fax: +44(0)1604-893-868. E-mail: pcn@bindt.org PCN/GEN ISO 20807 Appendix

More information

JAMES R. KNIGHT

JAMES R. KNIGHT JAMES R. KNIGHT knightjr@ah.org James is currently the supervisor of clinical engineering at Sonora Regional Medical Center. He is the chairman of the CMIA Training & Education Committee. He also develops

More information

A STUDY OF ULTRASOUND MEASUREMENT UTILIZED FOR THE LIVER TESTING

A STUDY OF ULTRASOUND MEASUREMENT UTILIZED FOR THE LIVER TESTING INTERNATIONNAL JOURNAL OF APPLIED BIOMEDICAL ENGINEERING VOL.4, NO.1 2011 19 A STUDY OF ULTRASOUND MEASUREMENT UTILIZED FOR THE LIVER TESTING Adisorn Leelasantitham and Supaporn Kiattisin, ABSTRACT Presently,

More information

OPTION I TEST REVIEW

OPTION I TEST REVIEW IB PHYSICS 3 Name: Period: Date: DEVIL PHYSICS BADDEST CLASS ON CAMPUS OPTION I TEST REVIEW s2. This question is about defects of hearing. The graph below shows an audiogram for a person who has not been

More information

Ractopamine Treatment Biases in the Prediction of Fat-free Lean Mass

Ractopamine Treatment Biases in the Prediction of Fat-free Lean Mass Ractopamine Treatment Biases in the Prediction of Fat-free Lean Mass A. P. Schinckel, C. T. Herr, B. T. Richert, and M. E. Einstein Department of Animal Sciences Introduction Numerous research trials have

More information

Inspection of Polyethylene Fusions and Electrofusions

Inspection of Polyethylene Fusions and Electrofusions Abstract Inspection of Polyethylene Fusions and Electrofusions Dr. Ken Oliphant, Dr. Peter Angelo and Patrick Vibien, JANA Corporation Dr. Andy Burns and Dr. Michail Kalloudis, Impact Solutions For buried

More information

Superchilling of organic food. Part 2: Storage test with superchilled organic salmon and pork chops

Superchilling of organic food. Part 2: Storage test with superchilled organic salmon and pork chops - Unrestricted Report Superchilling of organic food Part 2: Storage test with superchilled organic salmon and pork chops Authors Ingrid Camilla Claussen Per Egil Gullsvåg; Michael Bantle; Ignat Tolstorebrov;

More information

Ageing of Solid Rocket Propellants Investigated by Ultrasound Technique

Ageing of Solid Rocket Propellants Investigated by Ultrasound Technique Bulgarian Society for NDT International Journal NDT Days Volume 1, Issue 5, Year 018 ISSN: 603-4018 Ageing of Solid Rocket Propellants Investigated by Ultrasound Technique More info about this article:

More information

Dr Emma Chung. Safety first - Physical principles for excellent imaging

Dr Emma Chung. Safety first - Physical principles for excellent imaging Safety first - Physical principles for excellent imaging Dr Emma Chung Lecturer in Medical Physics, University of Leicester Clinical Scientist, University Hospitals of Leicester NHS Trust Thanks to Caroline

More information

HAND HELD ULTRASONIC SIZING OF STRESS CORROSION CRACKING

HAND HELD ULTRASONIC SIZING OF STRESS CORROSION CRACKING ABSTRACT HAND HELD ULTRASONIC SIZING OF STRESS CORROSION CRACKING Jim Marr, (Director)Marr Associates Robert Ginzel (President), James Pennie,Eclipse Scientific Products Inc. Stress corrosion cracking

More information

Rumpa Linpiyawan, MD. Biography - Certified Board of Internal Medicine - Certified Board of Dermatology, Board of Family Medicine

Rumpa Linpiyawan, MD. Biography - Certified Board of Internal Medicine - Certified Board of Dermatology, Board of Family Medicine Rumpa Linpiyawan, MD Biography - Certified Board of Internal Medicine - Certified Board of Dermatology, Board of Family Medicine Dr. Rumpa is a well-known dermatologist who had been assistant Professor

More information

Case studies on uncertainties of ultrasonic weld testing interpretation

Case studies on uncertainties of ultrasonic weld testing interpretation 17th World Conference on Nondestructive Testing, 5-8 Oct 008, Shanghai, China Case studies on uncertainties of ultrasonic weld testing interpretation Kuppusamy NACHIMUTHU 1, Sajeesh Kumar BABU 1 Non Destructive

More information

Inspection of High Temperature Pipe-work using Guided Waves Mark J. EVANS 1, Simon BUTLER 2

Inspection of High Temperature Pipe-work using Guided Waves Mark J. EVANS 1, Simon BUTLER 2 18th World Conference on Non-destructive Testing, 16-20 April 2012, Durban, South Africa Inspection of High Temperature Pipe-work using Guided Waves Mark J. EVANS 1, Simon BUTLER 2 1 Guided Ultrasonics

More information

PART 1c: Time of Flight Diffraction Ultrasonic Inspector (TOFD) of Welds in Ferritic and Non-Ferritic Materials, Levels 1, 2 and 3

PART 1c: Time of Flight Diffraction Ultrasonic Inspector (TOFD) of Welds in Ferritic and Non-Ferritic Materials, Levels 1, 2 and 3 CERTIFICATION SCHEME FOR PERSONNEL DOCUMENT No. CSWIP-ISO-NDT-11/93-R Requirements for the Certification of Personnel Engaged in Non- Destructive Testing in accordance with the requirement of BS EN ISO

More information

Terminology Tissue Appearance

Terminology Tissue Appearance By Marc Nielsen, MD Advantages/Disadvantages Generation of Image Ultrasound Machine/Transducer selection Modes of Ultrasound Terminology Tissue Appearance Scanning Technique Real-time Portable No ionizing

More information

Optimization of Vacuum Frying Condition for Shallot

Optimization of Vacuum Frying Condition for Shallot Kasetsart J. (Nat. Sci.) 41 : 338-342 (2007) Optimization of Vacuum Frying Condition for Shallot Nantawan Therdthai*, Phaisan Wuttijumnong, Anuvat Jangchud and Chatlada Kusucharid ABSTRACT Nowadays, healthy

More information

Routine Quality Assurance Cookbook

Routine Quality Assurance Cookbook This Cookbook is a companion guide to the AIUM Routine Quality Assurance (QA) for Diagnostic Ultrasound Equipment document, which outlines the basic QA requirements for AIUM-accredited practices. The Guide

More information

TG-128: Quality Assurance for Prostate Brachytherapy Ultrasound

TG-128: Quality Assurance for Prostate Brachytherapy Ultrasound TG-128: Quality Assurance for Prostate Brachytherapy Ultrasound STEVEN SUTLIEF DOUG PFEIFFER (HEATHER PIERCE, WENGZHENG FENG, JIM KOFLER) AAPM ANNUAL MEETING 2010 Educational Objectives To describe the

More information

Improved ultrasound-based navigation for robotic drilling at the lateral skull base

Improved ultrasound-based navigation for robotic drilling at the lateral skull base International Congress Series 1268 (2004) 662 666 Improved ultrasound-based navigation for robotic drilling at the lateral skull base U.W. Geisthoff a, *, S.H. Tretbar b, Ph.A. Federspil a, P.K. Plinkert

More information

Reliability Analysis of the Phased-Array Ultrasonic System used for the Inspection of Friction Stir Welds of Copper Canisters

Reliability Analysis of the Phased-Array Ultrasonic System used for the Inspection of Friction Stir Welds of Copper Canisters 19 th World Conference on Non-Destructive Testing 2016 Reliability Analysis of the Phased-Array Ultrasonic System used for the Inspection of Friction Stir Welds of Copper Canisters Mato PAVLOVIC 1, Christina

More information

Augmentation of the In Vivo Elastic Properties Measurement System to include Bulk Properties

Augmentation of the In Vivo Elastic Properties Measurement System to include Bulk Properties DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Augmentation of the In Vivo Elastic Properties Measurement System to include Bulk Properties Peter H. Rogers and Michael

More information

Ultrasonic Phased Array Testing of Complex Aircraft Structures

Ultrasonic Phased Array Testing of Complex Aircraft Structures ECNDT 2006 - Tu.1.1.2 Ultrasonic Phased Array Testing of Complex Aircraft Structures Ernst RAU, Ernst GRAUVOGL, Holger MANZKE, EADS Mil., Manching, Germany Philippe CYR, Olympus NDT, Québec, Canada 1.

More information

New Ultrasound System for Bone Assessment

New Ultrasound System for Bone Assessment New Ultrasound System for Bone Assessment Jonathan J. Kaufman a,b, Gangming Luo c, David Conroy d, William A. Johnson e, Ronald L. Altman e, Robert S. Siffert b a CyberLogic, Inc., 611 Broadway, Suite

More information

Analysis of Body Composition Changes of Swine During Growth and Development

Analysis of Body Composition Changes of Swine During Growth and Development Introduction Analysis of Body Composition Changes of Swine During Growth and Development A.P. Schinckel, J.C. Forrest, J.R. Wagner, W. Chen, M.E. Einsten, and B.L. Coe Department of Animal Sciences Mathematical

More information

SONIMAGE HS1. Premium Portable Ultrasound

SONIMAGE HS1. Premium Portable Ultrasound SONIMAGE HS1 Premium Portable Ultrasound EXIT SET F2 F1 User User Gain FREEZE PREMIUM PORTABLE ULTRASOUND DESIGNED FOR YOU Sonimage HS1 2 Sonimage HS1 is Konica Minolta s Premium Portable Ultrasound designed

More information

A-level APPLIED SCIENCE

A-level APPLIED SCIENCE Please write clearly in block capitals. Centre number Candidate number Surname Forename(s) Candidate signature A-level APPLIED SCIENCE Unit 8 Medical Physics Tuesday 24 May 2016 Morning Time allowed: 1

More information

MATCHING LAYER DESIGN OF AN ULTRASONIC TRANS- DUCER FOR WIRELESS POWER TRANSFER SYSTEM

MATCHING LAYER DESIGN OF AN ULTRASONIC TRANS- DUCER FOR WIRELESS POWER TRANSFER SYSTEM MATCHIN LAYE DESIN OF AN ULTASONIC TANS- DUCE FO WIELESS POWE TANSFE SYSTEM unn Hang Electronics and Telecommunications esearch Institute, Multidisciplinary Sensor esearch roup, Daejeon, South Korea email:

More information

Mul-ti Mode Ultrasonic Thickness Gauge MT180/190 User s Manual

Mul-ti Mode Ultrasonic Thickness Gauge MT180/190 User s Manual Mul-ti Mode Ultrasonic Thickness Gauge MT180/190 User s Manual MITECH CO., LTD. www.mitech-ndt.com CONTENTS 1 Overview... 3 1.1 Product Specifications... 3 1.2 Main Functions...3 1.3 Measuring Principle...3

More information

Hand Held Ultrasonic Sizing of Stress Corrosion Cracking

Hand Held Ultrasonic Sizing of Stress Corrosion Cracking ECNDT 2006 - Tu.4.1.5 Hand Held Ultrasonic Sizing of Stress Corrosion Cracking Robert GINZEL, James PENNIE, Eclipse Scientific Products Inc, Kitchener, ON, Canada Jim MARR, Marr Associate Inc., Calgary,

More information

INFLUENCE OF AFTERBODY SHAPE ANGLE OF TRAPEZOIDAL BLUFF BODY ON MEASURED SIGNAL PARAMETERS

INFLUENCE OF AFTERBODY SHAPE ANGLE OF TRAPEZOIDAL BLUFF BODY ON MEASURED SIGNAL PARAMETERS 27 P a g e INFLUENCE OF AFTERBODY SHAPE ANGLE OF TRAPEZOIDAL BLUFF BODY ON MEASURED SIGNAL PARAMETERS ATUL BACHAL Mechanical Department, Government College of Engineering Aurnagbad, MH, India, atul.bachal@in.endress.com

More information

Underwater Acoustic Measurements in Megahertz Frequency Range.

Underwater Acoustic Measurements in Megahertz Frequency Range. Underwater Acoustic Measurements in Megahertz Frequency Range. Current State and Prospects of Development in Russia Alexander M. Enyakov,, Many medical applications of underwater acoustic measurements

More information

Annular Array Transducer and Matched Amplifier for Therapeutic Ultrasound

Annular Array Transducer and Matched Amplifier for Therapeutic Ultrasound ARCHIVES OF ACOUSTICS 35, 4, 653 660 (2010) DOI: 10.2478/v10168-010-0049-6 Annular Array Transducer and Matched Amplifier for Therapeutic Ultrasound Wojciech SECOMSKI, Andrzej NOWICKI, Janusz WÓJCIK, Marcin

More information

COMPARISON OF ATTENUATION AND PHASE VELOCITY MEASUREMENTS IN

COMPARISON OF ATTENUATION AND PHASE VELOCITY MEASUREMENTS IN COMPARISON OF ATTENUATION AND PHASE VELOCITY MEASUREMENTS IN COMPOSITES MADE USING UNIPOLAR AND BIPOLAR PULSES INTRODUCTION M. S. Hughes 1, D. K. Hsu 1, S.J. Wormleyl, J. M. Mann 1, C. M. Fortunk 2, and

More information

Feasibility Evaluation of a Novel Ultrasonic Method for Prosthetic Control ECE-492/3 Senior Design Project Fall 2011

Feasibility Evaluation of a Novel Ultrasonic Method for Prosthetic Control ECE-492/3 Senior Design Project Fall 2011 Feasibility Evaluation of a Novel Ultrasonic Method for Prosthetic Control ECE-492/3 Senior Design Project Fall 2011 Electrical and Computer Engineering Department Volgenau School of Engineering George

More information

Blood Pressure Estimation Using Photoplethysmography (PPG)

Blood Pressure Estimation Using Photoplethysmography (PPG) Blood Pressure Estimation Using Photoplethysmography (PPG) 1 Siddhi Sham Karande, BE E&TC, VIIT Pune. 2 Kiran Rajendrasingh Thakur, BE E&TC, VIIT Pune. 3 Sneha Dattatraya Waghmare, BE E&TC, VIIT Pune 4

More information

Sound in medicine. CH.12. Dr.Rajaa أ.م.د. رجاء سهيل جنم جامعة تكريت كلية طب االسنان. General Properties of Sound

Sound in medicine. CH.12. Dr.Rajaa أ.م.د. رجاء سهيل جنم جامعة تكريت كلية طب االسنان. General Properties of Sound CH.12. Dr.Rajaa Sound in medicine أ.م.د. رجاء سهيل جنم جامعة تكريت كلية Sound : It is the audible waves of frequency between 20 Hz and 20 khz. Infrasound : refers to the sound of frequency below the normal

More information

Phased Array Ultrasonics and Eddy Current Examination for Graphite Components

Phased Array Ultrasonics and Eddy Current Examination for Graphite Components Phased Array Ultrasonics and Eddy Current Examination for Graphite Components www.inl.gov June 22, 2011 12 th International Symposium on Nondestructive Characterization of Materials Blacksburg, Virginia

More information

Effect of Washing on Quality Improvement of Mechanically Deboned Chicken Meat

Effect of Washing on Quality Improvement of Mechanically Deboned Chicken Meat Effect of Washing on Quality Improvement of Mechanically Deboned Chicken Meat Cho Cho Thein 1* and Kanithaporn Vangnai 2 ABSTRACT Mechanically deboned chicken meat (MDCM) is obtained from the skeletal

More information

Ultrasonic arrays are now widely used in underwater sonar

Ultrasonic arrays are now widely used in underwater sonar Ultrasonics NDT FUNDAMENTALS Part 12. Fundamentals of ultrasonic phased arrays S Cochran Ultrasonic arrays are now widely used in underwater sonar and in more than 25% of medical scans but their use in

More information

DC-6. Diagnostic Ultrasound System

DC-6. Diagnostic Ultrasound System DC-6 Diagnostic Ultrasound System MINDRAY is proud to introduce DC-6, a color Doppler ultrasound system for general applications. DC-6 incorporates the latest digital ultrasound image processing technology

More information

Obesity and Liver Disease:Evaluation of Fatty Infiltration of the Liver. Using Ultrasonic Attenuation

Obesity and Liver Disease:Evaluation of Fatty Infiltration of the Liver. Using Ultrasonic Attenuation J. Nutr. Sci. Vitaminol., 37, S71-S77, 1991 Obesity and Liver Disease:Evaluation of Fatty Infiltration of the Liver. Using Ultrasonic Attenuation Hideyukl FUSAMOTO, Kunio SuzuM, Norlo HAYASHI, Yutaka SASAKI,

More information

Egg Quality, Component Yield And Composition Responses To Different Levels Of Dietary Digestible Sulfur Amino Acids In Laying Hen

Egg Quality, Component Yield And Composition Responses To Different Levels Of Dietary Digestible Sulfur Amino Acids In Laying Hen Egg Quality, Component Yield And Composition Responses To Different Levels Of Dietary Digestible Sulfur Amino Acids In Laying Hen Reza Akbari Moghaddam Kakhki Akbarimoghaddam.reza@gmail.com Abolghassem

More information

Relationship Between Carcass End Points and USDA Marbling Quality Grades: A Progress Report

Relationship Between Carcass End Points and USDA Marbling Quality Grades: A Progress Report Beef Research Report, 1996 Animal Science Research Reports 1997 Relationship Between Carcass End Points and USDA Marbling Quality Grades: A Progress Report M. Izquierdo Doyle E. Wilson Gene P. Rouse V.

More information