A User-Friendly Thyroid Monitor

Size: px
Start display at page:

Download "A User-Friendly Thyroid Monitor"

Transcription

1 A User-Friendly Thyroid Monitor Herman Cember & Wei-Hsung Wang Purdue University, School of Health Sciences, 1338 Civil Engineering Building, West Lafayette, IN , USA ABSTRACT Good radiation safety practice includes routine thyroid monitoring for workers who are occupationally exposed to iodine-131. This work describes the design, construction, and calibration of a simple and reliable thyroid monitoring system. This system consists of a single channel analyzer and a sodium iodide detector mounted to assure a fixed and reproducible counting geometry. The system was calibrated using a mock thyroid into which a known iodine-131 activity was injected. The mock thyroid was made by inserting one thyroid-lobe shaped sponge into each of two glass vials. The two vials were capped and placed into a neck phantom. At a 5 cm skin to detector distance, the lower limit of detection was about 142 Bq (3.84 nano-curie). This detector system provides an easy, economic, and effective means to measure the internal radioiodine deposition in radiation workers and also meets both the regulatory standards and the good health physics practice. INTRODUCTION Iodine-131 (I-131) is widely used in the application of health physics, nuclear medicine, veterinary science, biology, and chemistry. It is also a significant fission product in a nuclear power plant. Because of its high volatility under room temperature, iodine can easily be inhaled by radiation researchers and workers due to an unknown or subtle release of radioiodine to the atmosphere. Healthy subjects accumulate about 30% of the inhaled iodine in the thyroid gland which is the critical organ for iodine (1). The thyroid gland is subject to radioiodine carcinogenesis (2). The United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) report suggested that a total risk of radiation induced thyroid cancer is per year per gray (3). Hence, the most efficient way to determine the internal deposition of iodine-131 is to perform in vivo measurement of the iodine-131 thyroid burden, and thus to prevent overexposure. According to the United States Nuclear Regulatory Commission's Title 10 Code of Federal Regulation (CFR) Part , it is required to monitor the occupational intake of radioactive material for radiation workers if they are likely to receive a yearly intake in excess of ten percent of the applicable annual limit on intake (ALI), as listed in Appendix B, 10 CFR 20. The inhalation ALI for I-131 is 50 µci and the corresponding derived air concentration (DAC) is 2 x 10-8 µci/ml. DAC means the concentration of a given radionuclide in air which, if breathed by the reference person for a working year of 2,000 hours under conditions of light work, results in an intake of one ALI. Kopp et al. (4) suggested using a high-purity germanium (HPGe) detector system for routine thyroid measurements of radioiodine in radiation workers. The cost of an HPGe detector system is much higher than a sodium iodide (NaI) scintillator monitoring system. The HPGe detector system has poorer counting efficiency than a NaI scintillator monitoring system. Besides, the HPGe detector must be operated at low temperature of 77 K (5). Tran (6) proposed to use two collimated 2" x 2" NaI detectors and a Canberra 1 System 100 Multi-Channel Analyzer to calibrate the I-131 uptake in the thyroid in a neck phantom provided by the Canadian Bureau of Radiation and Medical Devices. This detector system costs about $5,500 without the computer related expense. The report presented here describes a simpler user-friendly thyroid monitor. The monitor consists of an ORTEC 2 single channel analyzer (SCA) with a 1.25" diameter x 5/16" thick NaI detector that is calibrated for the assessment of I-131 uptake in the thyroid gland of radiation workers. This NaI scintillation counting system costs less and can also be applied to various other practices. This monitoring device provides an effective and economic way to demonstrate compliance with the regulatory limits. It also accomplishes good health physics practice to use radiation sources safely. MATERIAL AND METHODS COUNTING SYSTEM Scintillation counters have widespread uses in measuring gamma rays and low-energy beta rays. The NaI scintillator has a high sensitivity for the detection of gamma rays. When the analyzer of the scintillation counting system is in the differential mode, it operates as a single channel analyzer and allows only pulses of a certain size to be counted. The essentials of a single channel analysis system consist of a detector, a high voltage power supply, a linear amplifier, a pulse height analyzer, and a readout device (timer and counter). The main use of the SCA is to optimize the signal to noise ratio when measuring a low radioactivity source in the presence of a significant background (7). 1 Canberra Industries, 800 Research Parkway, Meriden, CT EG&G ORTEC, 100 Midland Road, Oak Ridge, TN

2 The sodium iodide counting system uses an ORTEC SCA to electronically process the signals from the iodine-131 radioactivity in the thyroid. A Harshaw " diameter x 5/16" thick NaI detector which can measure the radioactivity at levels well below legal limits was utilized. Iodine-131 emits several photons of different energies. In this case, we counted the signals from the 364 kev photons with a radiation abundance of 82% (8). The use of the SCA effectively reduced the background count rate to a very low level relative to the I- 131 activity in the thyroid at levels of interest to the health physicist. PREPARATION OF THE COUNTING SYSTEM 1. Determination of the Operating Voltage Most photomultiplier (PM) tubes commonly used with a NaI crystal operate well in the 800-volt to 1,100-volt range. The appropriate high voltage setting is obtained by plotting the integral count rate vs. high voltage with the analyzer in the integral mode. In the integral mode, all pulses greater than a given size are counted. As a good rule of thumb, the operating voltage should be selected relatively close to the threshold voltage (within the lower 25% of the plateau). Since the plateau curves for different gamma-emitting nuclides vary somewhat, the operating potential must be determined individually for each isotope used (9). In order to obtain a good voltage curve, at least 30 minutes should elapse between successive increases in voltage to allow the PM tube to stabilize. This stabilization period helps minimize the variations in output voltage and ambient temperature due to the voltage shifts in the PM tube. The operating voltage should be chosen to avoid the rapidly rising thermal noise level at the higher voltages and to help preserve the life of the PM tube. The operating voltage is determined on statistical grounds as that voltage where the ratio of the square of the gross sample count rate to the total background count rate is at maximum (10). Results from this procedure are shown in Table 1 and Figure 1. From the data on Table 1, 925-volt was selected as the operating voltage. Voltage (volts) Gross (cpm) BKG (cpm) Net (cpm) (Gross) 2 /BKG * Gross: gross sample counting rate in counts per minute ** BKG: background counting rate in counts per minute *** Net: net counting rate in counts per minute = (Gross - BKG) Table 1. Determination of the Operating Voltage 3 Harshaw Chemical Company, Cleveland, Ohio 2

3 counting rate (cpm) Net Counting voltage (volts) Figure 1. Plot of Integral Count Rate vs. High Voltage 2. Energy Calibration An SCA must be calibrated before performing any sorting of the pulse sizes produced in the analyzer. The 364 kev gamma photon from I-131 was chosen for the calibration. A window can be established using the base and upper discriminators of the analyzer. This window must be wide enough to allow a narrow range in pulse sizes to get through, but not too wide or the calibration will be inaccurate. A window whose width is about 5-10% of the full energy peak is usually acceptable. This window should be placed on the division scale of the base discriminator so that a division will correspond to a gamma ray with a given energy. For this experiment, the base discriminator was set at 354 and with a 20-division window and so the center was at 364. With this analyzer setup, pulses corresponding to energies between 354 and 374 kev would pass through this window. After the 364 kev photopeak had been defined, a calibration plot of I-131 was also established to provide the complete information on the shape and position of the photopeak and help confirm the discriminator settings. The amplifier's coarse and fine gains were adjusted to maximize the counting rates in the kev channel. The data and the calibration plot of I-131spectrum are shown in Table 2 and Figure 2. Base Gross BKG Net Base Gross BKG Net * Base: base discriminator setting ** All counting rate measurements are in counts per minute *** Instrument settings: high voltage = 925 volts; coarse gain = 1K; fine gain = 1.24 Table 2. Determination of Iodine-131 Spectrum 3

4 counting rate (cpm) Net Counting Rate base discriminator setting Figure 2. Iodine-131 Spectrum THYROID MODEL Standard radiation absorbed doses are calculated for the reference person. The thyroid gland of a reference person weighs 20 g (11). Each adult lateral lobe is 2 cm x 2 cm x 4 cm, elongated in the cephalocaudal dimensions, and opposed on either side of the trachea, with the isthmus connecting the two lobes (12). Each of two simulated thyroid lobes made of sponge were placed into 15 ml vials to represent the thyroid organ. The breadth of the isthmus is 1.25 cm (13). The three thyroid organ components were positioned into a 13 cm diameter water filled plastic bottle representing the neck phantom (14). The anterior surface of the three components is 1 cm behind the outside surface of the phantom (14). The two vials were fixed at a center to center separation distance of 3.3 cm between the "lobes". Since the trachea, esophagus, and pharynx lie behind the thyroid, no photon originating from the thyroid could pass through these regions and still deposit its full energy in the detector. SETUP AND CALIBRATION OF THE COUNTING SYSTEM Simulated in vivo measurements of the thyroid were made by positioning a sodium iodide detector 5 cm from the anterior surface of the neck, centered over the isthmus between the two thyroid lobes. The center of the thyroid was aligned with the center of the NaI detector. The geometrical arrangement of the cylinder, vials, and the detector used during the experiments is shown in Figure 3. The arrangement and geometry were maintained the same for all measurements. This counting system must be appropriately calibrated to infer the I-131 thyroid burden from the measurement. Calibration was performed using an I-131 source and the neck phantom as shown in Figure 3. The I-131 source was in the form of sodium iodide solution. 7.4 kbq (0.2 µci) in 10 ml aqueous solution was injected into each "lobe". The amount of 14.8 kbq (0.4 µci) represents sixty-three percent of the maximum allowable eight-hour uptake of I-131 in the thyroid based on an ALI of 50 µci. Both thyroid and background measurements were carried out for 1,000 seconds each for continuous seven weeks. All measurements were taken at the same time everyday. Because the half-life of I-131 is much longer than the sample counting time, no correction for the counting time is needed. A plot of the net count rate of I-131 on the ordinate versus the absolute activity of I-131 on the abscissa was generated to provide a calibration curve for the thyroid monitoring. Since I-131 activity in the thyroid was related to the count rate, one could easily determine the radioiodine deposition in the thyroid. After the monitoring system has been calibrated, the counting efficiency of the NaI detector should be determined. Counting efficiency can be calculated using the ratio of the net count rate to the absolute activity of a radionuclide. The geometry of the detector and source arrangements must be fixed in order to have a constant counting efficiency. The lower limit of detection (LLD) of the monitoring system is dependent on both the detector efficiency and the counting time. The LLD should be well below the activity level of concern in operational radiation protection. 4

5 Side View 13 cm water filled 1 cm SCA 15 cm 5 cm 2 cm NaI detector within lead shield neck surface Top View 2 cm neck surface 13 cm 3.3 cm SCA 3.5 cm 5 cm isthmus :simulated thyroid lobe :detector :lead shield Figure 3. Geometry Details of the Thyroid Organ Model within the Neck Phantom RESULTS AND DISCUSSION The data and plot of the calibration are shown in Table 3 and Figure 4. The radiation background is in the range of 6 to 10 counts per minute. The calibration curve indicates a perfect linear relationship between the calculated activity and the measured net count rate (r 2 = ). This straight line also suggests that this thyroid monitoring system performed stably. The counting efficiency of the NaI detector can be easily obtained from the estimated regression function, y(cpm) = x(µci), on the calibration plot in Figure 4. The slope of cpm/µci of the regression function represents the counting efficiency of the NaI detector at this specific setup. 5

6 Day Gross BKG Net Act calc Day Gross BKG Net Act calc * Gross sample counting rate and background counting rate are in counts per 1,000 seconds ** Net counting rate is in counts per minute *** Act calc : calculated activity of I-131 based on the original activity of 0.4 µci (14.8 kbq) using the radioactive decay equation Table 3. Calibration Data of Iodine-131 counting rate (cpm) Net Counting Rate y = x r 2 = calculated activity (uci) Figure 4. Calibration Curve of Iodine-131 Monitoring System When the sample counting time is 100 seconds and the background counting time is 1,000 seconds, the LLD, in units of counts, during the 100-second sample counting time is given by (7): 6

7 t g LLD = 3.29 rb t g (1 + ) + 3 t b where r b is the background counting rate t g is the sample counting time t b is the background counting time At a maximum background count of 166 in 1,000 seconds, LLD = 3.29 = 10.24cpm above background LLD = cpm 166 counts 100 seconds counts 100 seconds (1 + ) seconds 1000 seconds 100 seconds μci 1000 nci = 3.84 nci cpm μci 37 Bq LLD = 3.84 nci = 142 Bq nci Therefore, the most conservative estimate of the LLD of this thyroid monitoring system was 142 Bq (3.84 nci) above the background for a 100 second monitoring time. At equilibrium, the accumulation rate of I-131 in the thyroid is equal to the removal rate of I-131 from the thyroid. With an ALI of 50 µci, the steady state activity of I-131 in the thyroid for an eight-hour working day can be calculated as follows, 50 μci 0.3 hours 1 8 = Q μci λe 2000 hours day day where 0.3 represents that 30% of the inhaled iodine is deposited in the thyroid 2000 hours represent the total working hours per working year 8 hours/day represent the total working hours per working day Q µci represents the steady state activity of I-131 in the thyroid λ e day -1 represents the effective clearance constant of I-131 in the thyroid In order to obtain λ e, we need to know the effective half-life, T e, which can be computed from the following formula, Tr Tb Te = Tr + Tb where T r represents the radiological half-life of I-131 of 8.04 days T b represents the biological half-life of I-131 of 80 days (15) Substituting the appropriate values into equation and solving for T e yields: 60 seconds 1minute So the effective clearance constant λ e is 8.04 days 80 days = 8.04 days + 80 days Te = 7.3 days λe = = days day The solution for the steady state activity of I-131 in the thyroid is given by hours 50 μci day Q = = 0.63μCi hours day The value of 0.63 µci represents the maximum allowable eight-hour deposition of I-131 in the thyroid based on an ALI of 50 µci. The sensitivity of this detector system can also be computed as follows, In other words, this thyroid monitoring system is capable of measuring 0.61% of the maximum allowable eighthour thyroid burden. LLD 3.84 nci 1μCi = 100% = 0.61% Q 0.63μCi 1000 nci 7

8 MONITORING SYSTEM STEUP The elements of this thyroid monitoring system are shown in Figure 5. The radiation worker places his/her chin on the chin rest to keep a fixed position during the counting period of 100 seconds. There is a Styrofoam spacer between the worker's neck and the detector to maintain a constant and reproducible geometry. The NaI detector is within lead shield which is mounted to the bottom of the chin rest. NaI detector within lead shield Styrofoam spacer 5 cm SCA : chin rest : clamp : thyroid lobe Figure 5. Setup of the Thyroid Monitoring System CONCLUSION 1. This thyroid monitoring system has reproducible geometry and stable performance. 2. The background count rate was in the range of 6 to 10 cpm with a 20 kev wide window of the analyzer. 3. With a thyroid monitoring time of 100 seconds, the lower limit of detection for this monitoring system is about 142 Bq (3.84 nci) at a 10 cpm background with a background counting time of 1,000 seconds. 4. This monitoring system is able to measure 0.61% of the maximum allowable eight-hour thyroid burden. 5. This monitoring system provides an easy, effective, and economic means not only to measure the internal radioiodine deposition for the radiation workers but also to demonstrate compliance with the regulatory limits. ACKNOWLEDGMENT The radioiodine used in this project was provided by Syncor 4 International Corporation. The authors greatly appreciated the generous offer of Syncor. Thanks are extended to Ms. Kara Duncan of Syncor for her continuous assistance. REFERENCES 1. International Commission on Radiological Protection. Limits for intakes of radionuclides by workers. Oxford: Pergamon Press; ICRP; Publication 30; Syncor International Corporation, 7920 Georgetown Road, Suite 100, Indianapolis, IN

9 2. Hall, E. J., Radiobiology for the Radiologist. Philadelphia: J. B. Lippincott, United Nations Scientific Committee on the Effects of Atomic Radiation, Sources, Effects, and Risks of Ionization Radiation. New York: UNSCEAR, Kopp, P.; Bergmann, H.; Havlik, E.; Aiginger, H.; Unfried, E. and Riedlmayer, L., "The Use of a High- Purity Germanium Detector for Routine Measurements of I-125 in Radiation Workers." Health Physics, Vol. 67, No. 6, pp , Knoll, G. F., Radiation Protection and Measurement. Singapore: John Wiley & Sons, Tran, T. D., "Thyroid Monitoring Program at Nordion International, Inc." Radiation Protection Management, Vol. 11, No. 6, pp , Cember, H., Introduction to Health Physics. New York: Pergamon Press, Radiological Health Handbook, Revised ed. U.S. Dept. of Health, Education, and Welfare, Public Health Service, Rockville, M.D., Wang, C. H. and Willis, D. L., Radiation Methodology in Biological Science. Englewood Cliff, N.J.: Prentice-Hall, Inc., Wang, C. H., Willis, D. L., and Loveland, W. D., Radiotracer Methodology in the Biological, Environmental, and Physical Sciences. Englewood Cliff, N.J.: Prentice-Hall, Inc., International Commission on Radiological Protection. Report of the Task Group on Reference Man. Oxford: Pergamon Press; ICRP; Publication 23; Dulbecco, R., Encyclopedia of Human Biology. San Diego, C.A.: Academic Press, Falk, S. A., Thyroid Disease: Endocrinology, Surgery, Nuclear Medicine, and Radiotherapy. New York: Raven Press, Mallett, M. W., "Thyroid Calibration Method for In Vivo Measurement Systems Using Monte Carlo Computations." Radiation Protection management, Vol. 13, No. 1, pp , International Commission on Radiological Protection. Individual Monitoring for Intakes of Radionuclides by Workers: Design and Interpretation. Oxford: Pergamon Press; ICRP; Publication 54;

Personnel internal radiation exposure to iodine-125 in a radioiodination laboratory: Exposure levels and trends

Personnel internal radiation exposure to iodine-125 in a radioiodination laboratory: Exposure levels and trends Iran. J. Radiat. Res., 2005; 3 (3): 117-122 Personnel internal radiation exposure to iodine-125 in a radioiodination laboratory: Exposure levels and trends F.Atabi 1, N.Alirezazadeh 2*, H. Garshasbi 2,

More information

Monitoring of iodine-125 and iodine-131 in thyroid of individuals in nuclear medicine centers of North West provinces of Iran

Monitoring of iodine-125 and iodine-131 in thyroid of individuals in nuclear medicine centers of North West provinces of Iran Iran. J. Radiat. Res., 2004; 2 (3): 141-147 Monitoring of iodine-125 and iodine-131 in thyroid of individuals in nuclear medicine centers of North West provinces of Iran G.H. Heravi, H. Garshasbi *, J.

More information

Ionizing Radiation. Michael J. Vala, CHP. Bristol-Myers Squibb

Ionizing Radiation. Michael J. Vala, CHP. Bristol-Myers Squibb Ionizing Radiation Michael J. Vala, CHP Bristol-Myers Squibb michael.vala@bms.com 732-227-5096 2013 American Industrial Hygiene Association, New Jersey Section, Inc. Course Objectives At the end of this

More information

Internal Dosimetry of Human Brain for 99m tc and 131 I Using Nuclear Imaging in Bangladesh

Internal Dosimetry of Human Brain for 99m tc and 131 I Using Nuclear Imaging in Bangladesh Sri Lankan Journal of Physics, Vol. 6 (2005) 33-41 Institute of Physics - Sri Lanka Internal Dosimetry of Human Brain for 99m tc and 131 I Using Nuclear Imaging in Bangladesh M. M. Alam a, M. I. Kabir

More information

Study of Performance of Thyroid Counter for Monitoring of Intake of Iodine-131 among Radiation Workers in Malaysia

Study of Performance of Thyroid Counter for Monitoring of Intake of Iodine-131 among Radiation Workers in Malaysia ISSN:1991-8178 Australian Journal of Basic and Applied Sciences Journal home page: www.ajbasweb.com Study of Performance of Thyroid Counter for Monitoring of Intake of Iodine-131 among Radiation Workers

More information

Captus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive

Captus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive Captus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive Performing Thyroid Uptake measurements has never been easier. The Captus 3000 combines a software program with the

More information

8.05 days 138 days 7.60 days 0.22 mr/h at 1.0 meter per millicurie 124,068 curies/gram 2 mm = 0.20 cm = 0.08 in 165 cm = 65.0 in = 5.

8.05 days 138 days 7.60 days 0.22 mr/h at 1.0 meter per millicurie 124,068 curies/gram 2 mm = 0.20 cm = 0.08 in 165 cm = 65.0 in = 5. Iodine-131 Radiological Safety Guidance Physical Data GAMMA ENERGIES 364 kev (82% abundance) 637 kev (7% abundance) 284 kev (6% abundance) 80 kev (3% abundance) 723 kev (2% abundance) 29-34 kev (4.5%/x-rays)

More information

Sodium Iodide I 131 Solution. Click Here to Continue. Click Here to Return to Table of Contents

Sodium Iodide I 131 Solution. Click Here to Continue. Click Here to Return to Table of Contents Sodium Iodide I 131 Solution Package inserts are current as of January, 1997. Contact Professional Services, 1-888-744-1414, regarding possible revisions Click Here to Continue Click Here to Return to

More information

Method for internal dose estimation of workers at the Fukushima Daiichi nuclear power station

Method for internal dose estimation of workers at the Fukushima Daiichi nuclear power station January 7, 2014 Tokyo Electric Power Company Method for internal dose estimation of workers at the Fukushima Daiichi nuclear power station TEPCO established a method of the dose estimation on August 2

More information

Radiation Detection and Measurement

Radiation Detection and Measurement Radiation Detection and Measurement Range of charged particles (e.g.,!: µm; ": mm) Range of high energy photons (cm) Two main types of interactions of high energy photons Compton scatter Photoelectric

More information

NaI Detector and Photo-multiplier Tubes

NaI Detector and Photo-multiplier Tubes NaI Detector and Photo-multiplier Tubes Summer 2014 UC Davis REU Program Jayss Marshall American River College/ UC Berkeley Advisor: Mani Tripathi August 28, 2014 Abstract A NaI Compton suppression system

More information

Austin Radiological Association Nuclear Medicine Procedure THYROID UPTAKE MEASUREMENT (I-123 or I-131 as Sodium Iodide)

Austin Radiological Association Nuclear Medicine Procedure THYROID UPTAKE MEASUREMENT (I-123 or I-131 as Sodium Iodide) Austin Radiological Association Nuclear Medicine Procedure THYROID UPTAKE MEASUREMENT (I-123 or I-131 as Sodium Iodide) Overview Indications The Thyroid Uptake Measurement measures the metabolic activity

More information

STANDARDIZED RADIOGENIC CANCER RISK COEFFICIENTS: A REVIEW OF THE METHODOLOGY PRESENTED IN FEDERAL GUIDANCE REPORT NO. 13

STANDARDIZED RADIOGENIC CANCER RISK COEFFICIENTS: A REVIEW OF THE METHODOLOGY PRESENTED IN FEDERAL GUIDANCE REPORT NO. 13 STANDARDIZED RADIOGENIC CANCER RISK COEFFICIENTS: A REVIEW OF THE METHODOLOGY PRESENTED IN FEDERAL GUIDANCE REPORT NO. 13 ABSTRACT Michael Boyd and Christopher Nelson, U.S. Environmental Protection, Office

More information

Adult: > 18 Years ALARA: As low as reasonably achievable ALI:

Adult: > 18 Years ALARA: As low as reasonably achievable ALI: Health Physics Adult: > 18 Years ALARA: As low as reasonably achievable ALI: Annual Limit on Intake. The amount of an isotope that if taken into the body over the course of a year would result in in a

More information

IONIZING RADIATION, HEALTH EFFECTS AND PROTECTIVE MEASURES

IONIZING RADIATION, HEALTH EFFECTS AND PROTECTIVE MEASURES May 2011 IONIZING RADIATION, HEALTH EFFECTS AND PROTECTIVE MEASURES KEY FACTS Ionizing radiation is a type of energy released by atoms in the form of electromagnetic waves or particles. People are exposed

More information

EVALUATION OF INTERNAL CONTAMINATION LEVELS AFTER A RADIOLOGICAL DISPERSAL DEVICE USING PORTAL MONITORS. A Thesis Presented to The Academic Faculty

EVALUATION OF INTERNAL CONTAMINATION LEVELS AFTER A RADIOLOGICAL DISPERSAL DEVICE USING PORTAL MONITORS. A Thesis Presented to The Academic Faculty EVALUATION OF INTERNAL CONTAMINATION LEVELS AFTER A RADIOLOGICAL DISPERSAL DEVICE USING PORTAL MONITORS A Thesis Presented to The Academic Faculty by Randahl Christelle Palmer In Partial Fulfillment of

More information

United Nations Scientific Committee on the Effects of Atomic Radiation

United Nations Scientific Committee on the Effects of Atomic Radiation United Nations Scientific Committee on the Effects of Atomic Radiation ATTACHMENT D-1 ESTIMATION OF THE POSSIBLE CONTRIBUTION OF INTAKES OF SHORT-LIVED RADIONUCLIDES TO EFFECTIVE DOSE AND ABSORBED DOSES

More information

Radiation Protection Program Update: The Details. July 2010

Radiation Protection Program Update: The Details. July 2010 Radiation Protection Program Update: The Details July 2010 Update Topics 2 Changes mandated by Title 10, Code of Federal Regulations, Part 835, Occupational Radiation Protection (10 CFR 835) How changes

More information

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. L19: Optimization of Protection in Mammography

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. L19: Optimization of Protection in Mammography IAEA Training Material on Radiation Protection in Diagnostic and Interventional Radiology RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY L19: Optimization of Protection in Mammography

More information

Radiation physics and radiation protection. University of Szeged Department of Nuclear Medicine

Radiation physics and radiation protection. University of Szeged Department of Nuclear Medicine Radiation physics and radiation protection University of Szeged Department of Nuclear Medicine Radiation doses to the population 1 Radiation doses to the population 2 Sources of radiation 1 Radiation we

More information

QUANTIFICATION OF THE RISK-REFLECTING STOCHASTIC AND DETERMINISTIC RADIATION EFFECTS

QUANTIFICATION OF THE RISK-REFLECTING STOCHASTIC AND DETERMINISTIC RADIATION EFFECTS RAD Conference Proceedings, vol. 2, pp. 104 108, 2017 www.rad-proceedings.org QUANTIFICATION OF THE RISK-REFLECTING STOCHASTIC AND DETERMINISTIC RADIATION EFFECTS Jozef Sabol *, Bedřich Šesták Crisis Department,

More information

Comparison of absorbed fraction of Gamma and Beta rays of I-124 and I-131radio-isotopes in thyroid gland with Monte Carlo Simulation

Comparison of absorbed fraction of Gamma and Beta rays of I-124 and I-131radio-isotopes in thyroid gland with Monte Carlo Simulation Available online at http://www.ijabbr.com International journal of Advanced Biological and Biomedical Research Volume 1, Issue 9, 2013: 993-998 Comparison of absorbed fraction of Gamma and Beta rays of

More information

45 Hr PET Registry Review Course

45 Hr PET Registry Review Course 45 HR PET/CT REGISTRY REVIEW COURSE Course Control Document Timothy K. Marshel, MBA, R.T. (R), (N)(CT)(MR)(NCT)(PET)(CNMT) The PET/CT Training Institute, Inc. SNMMI-TS 028600-028632 45hr CEH s Voice Credits

More information

Basics of nuclear medicine

Basics of nuclear medicine Basics of nuclear medicine Prof. dr. Davor Eterović Prof. dr. Vinko Marković Radioisotopes are used both in diagnostics and in therapy Diagnostics gamma emitters are used since gamma rays can penetrate

More information

PERSONNEL MONITORING AND DOSIMETRY POLICIES

PERSONNEL MONITORING AND DOSIMETRY POLICIES PERSONNEL MONITORING AND DOSIMETRY POLICIES All individuals who are required to have their exposure to ionizing radiation monitored must be trained prior to using the source(s) of radiation. The radioactive

More information

Survey of Radiation Dose Levels in Patients in X-Ray Units of Some Selected Hospitals in Jos Metropolis

Survey of Radiation Dose Levels in Patients in X-Ray Units of Some Selected Hospitals in Jos Metropolis International Journal of Innovative Scientific & Engineering Technologies Research 6(4):1-9, Oct.-.Dec., 2018 SEAHI PUBLICATIONS, 2018 www.seahipaj.org ISSN: 2360-896X Survey of Radiation Dose Levels in

More information

User's Guide for the Interactive RadioEpidemiological Program (NIOSH-IREP)

User's Guide for the Interactive RadioEpidemiological Program (NIOSH-IREP) User's Guide for the Interactive RadioEpidemiological Program (NIOSH-IREP) Designed for use by the Department of Labor in adjudicating claims under the Energy Employees Occupational Illness Compensation

More information

THYROID UPTAKE SYSTEMS

THYROID UPTAKE SYSTEMS 76 CAPTUS 4000e THYROID UPTAKE SYSTEM New and improved stand provides ergonomically adjustable monitor and easy to position articulating collimator arm. Four sided comfortable handle grips and swivel wheels

More information

Section 7 ALARA Program

Section 7 ALARA Program Page 7-1 Section 7 ALARA Program Contents A. ALARA Principle... 7-2 1. Biological Basis... 7-2 2. Applied Practices... 7-3 3. Operational Dose Limits... 7-3 4. Collective Dose... 7-3 B. Radiation Safety

More information

Chapter 22 THYROID UPTAKE TEST. R.D. Ganatra

Chapter 22 THYROID UPTAKE TEST. R.D. Ganatra XA9847619 Chapter 22 THYROID UPTAKE TEST R.D. Ganatra Measurement of the uptake of the radioiodine by the thyroid gland was one of the earliest applications of the radioisotopes in medicine but in advanced

More information

Summary of Patient Release after Radioiodine Therapy Research Review

Summary of Patient Release after Radioiodine Therapy Research Review Summary of Patient Release after Radioiodine Therapy Research Review Introduction This report provides a summary of the Office of Research (RES) staff s efforts to evaluate radiation exposure to members

More information

A Simple Model for Establishing Exemption Limits

A Simple Model for Establishing Exemption Limits A Simple Model for Establishing Exemption Limits S. Baechler 1, A. Aroua 1, J.F. Valley 1, W. Zeller 2 1 University Institute of Applied Radiation Physics, Grand-Pré 1, CH-1007 Lausanne, Switzerland E-mail:

More information

Sampling and measurements, incl. analytical issues related to clearance

Sampling and measurements, incl. analytical issues related to clearance Sampling and measurements, incl. analytical issues related to clearance Dr. J. Feinhals, DMT Dr. M. Bothe, VKTA IAEA Regional Workshop on Clearance of Decommissioning Waste, Bangkok 6-9 Nov. 2012 1 Measurement

More information

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method Iran. J. Radiat. Res., 2004; 1(4): 187-194 Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method M.R. Ay 1, M. Shahriari 2, S. Sarkar 3, P.

More information

Click Here to Continue. Click Here to Return to Table of Contents

Click Here to Continue. Click Here to Return to Table of Contents Hippuran I 131 Injection Package inserts are current as of January, 1997. Contact Professional Services, 1-888-744-1414, regarding possible revisions Click Here to Continue Click Here to Return to Table

More information

BIOLOGICAL EFFECTS OF

BIOLOGICAL EFFECTS OF BIOLOGICAL EFFECTS OF RADIATION Natural Sources of Radiation Natural background radiation comes from three sources: Cosmic Radiation Terrestrial Radiation Internal Radiation 2 Natural Sources of Radiation

More information

The Principles of Radiation Monitoring and the Radiation Protection System in Hong Kong. H.M.Mok Physicist Radiation Health Unit Department of Health

The Principles of Radiation Monitoring and the Radiation Protection System in Hong Kong. H.M.Mok Physicist Radiation Health Unit Department of Health The Principles of Radiation Monitoring and the Radiation Protection System in Hong Kong H.M.Mok Physicist Radiation Health Unit Department of Health Contents Basic properties of ionising radiation and

More information

SUMMARY OF PERSONAL DOSIMETRY PRACTICIES IN RCA MEMBER COUNTRIES

SUMMARY OF PERSONAL DOSIMETRY PRACTICIES IN RCA MEMBER COUNTRIES A Personal Dosimetry Intercomparison Study in Asian and Pacific Region Hiroyuki MURAKAMI and Fumiaki TAKAHASHI Department of Health Physics, Japan Atomic Energy Research Institute and Richard V. Griffith

More information

Patient effective dose evaluation for chest X-ray examination in three digital radiography centers

Patient effective dose evaluation for chest X-ray examination in three digital radiography centers Patient effective dose evaluation for chest X-ray examination in three digital radiography centers R. Paydar 1,3*, A. Takavar 1, M.R. Kardan 2,3, A. Babakhani 3,4, M.R. Deevband 3, S. Saber 5 1Medical

More information

Atomlab. Thyroid Uptake System BIODEX. A complete, mobile, Medical Spectrometer. The Clinical Advantage.

Atomlab. Thyroid Uptake System BIODEX. A complete, mobile, Medical Spectrometer. The Clinical Advantage. The Clinical Advantage Atomlab Thyroid Uptake System A complete, mobile, self-contained Medical Spectrometer I S O 9 0 0 1: 2 0 0 8 I S O 1 3 4 8 5 : 2 0 0 3 C E R T I F I E D www.biodex.com 1-800-224-6339

More information

Results of the Additional Re-evaluation of Committed Effective Doses of Emergency Workers at TEPCO s Fukushima Daiichi Nuclear Power Plant

Results of the Additional Re-evaluation of Committed Effective Doses of Emergency Workers at TEPCO s Fukushima Daiichi Nuclear Power Plant Results of the Additional Re-evaluation of Committed Effective Doses of Emergency Workers at TEPCO s Fukushima Daiichi Nuclear Power Plant 25 March, 2014 Labour Standards Bureau Ministry of Health, Labour

More information

RADIATION SAFETY. Junior Radiology Course

RADIATION SAFETY. Junior Radiology Course RADIATION SAFETY Junior Radiology Course Expectations for the Junior Radiology Course Medical School wants students to learn basic principles, factual knowledge, safety info, etc. Medical Students want

More information

GUIDELINES ON IONISING RADIATION DOSE LIMITS AND ANNUAL LIMITS ON INTAKE OF RADIOACTIVE MATERIAL

GUIDELINES ON IONISING RADIATION DOSE LIMITS AND ANNUAL LIMITS ON INTAKE OF RADIOACTIVE MATERIAL RADIATION PROTECTION AUTHORITY OF ZIMBABWE (RPAZ) RADIATION PROTECTION ACT [CHAPTER 15:15] GUIDELINES ON IONISING RADIATION DOSE LIMITS AND ANNUAL LIMITS ON INTAKE OF RADIOACTIVE MATERIAL Compiled by Radiation

More information

RADIATION RISK ASSESSMENT

RADIATION RISK ASSESSMENT RADIATION RISK ASSESSMENT EXPOSURE and TOXITY ASSESSMENT Osipova Nina, associated professor, PhD in chemistry, Matveenko Irina, Associate professor, PhD in philology TOMSK -2013 The contents 1.What is

More information

Site Planning and Design of PET/CT Facilities. Melissa C. Martin, M.S., FACR, FAAPM AAPM Annual Meeting, Orlando, FL August 2, 2006

Site Planning and Design of PET/CT Facilities. Melissa C. Martin, M.S., FACR, FAAPM AAPM Annual Meeting, Orlando, FL August 2, 2006 Site Planning and Design of PET/CT Facilities Melissa C. Martin, M.S., FACR, FAAPM AAPM Annual Meeting, Orlando, FL August 2, 2006 Acknowledgements: AAPM Task Group #108 on PET and PET/CT Shielding Requirements

More information

RULES AND REGULATIONS

RULES AND REGULATIONS RI-12 RI-12 BIOASSAYS FOR INTERNAL RADIOACTIVITY PURPOSE This procedure specifies the requirements, responsibilities and methods for performing and reporting measurements for detecting and verifying the

More information

DRAXIMAGE SODIUM IODIDE I 131 CAPSULES, USP DIAGNOSTIC. For Oral Use DESCRIPTION

DRAXIMAGE SODIUM IODIDE I 131 CAPSULES, USP DIAGNOSTIC. For Oral Use DESCRIPTION DRAXIMAGE SODIUM IODIDE I 131 CAPSULES, USP DIAGNOSTIC For Oral Use DESCRIPTION Sodium Iodide I 131 Capsules, USP are color-coded capsules containing sodium iodide I 131 for diagnostic use by oral administration.

More information

3/26/2017. Personal Dosimetry Monitoring and Dose Measurements. Agenda. Dosimetric Terms and Definitions Dose Limits External Dosimetry

3/26/2017. Personal Dosimetry Monitoring and Dose Measurements. Agenda. Dosimetric Terms and Definitions Dose Limits External Dosimetry Speaker David Pellicciarini, CHP, MBA Vice President, Pharmacy Safety, Practice and Technical Operations Cardinal Health Nuclear Pharmacy Services david.pellicciarini@cardinalhealth.com Personal Dosimetry

More information

Radiation Safety for New Medical Physics Graduate Students

Radiation Safety for New Medical Physics Graduate Students Radiation Safety for New Medical Physics Graduate Students John Vetter, PhD Medical Physics Department UW School of Medicine & Public Health Background and Purpose of This Training This is intended as

More information

Twelfth Annual Warren K. Sinclair Keynote Address

Twelfth Annual Warren K. Sinclair Keynote Address THE INFLUENCE OF NCRP ON RADIATION PROTECTION IN THE U.S.: REGULATION AND GUIDANCE Twelfth Annual Warren K. Sinclair Keynote Address Kenneth R. Kase Annual Meeting of NCRP 16 March 2015 1 OUTLINE Introduction

More information

PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015)

PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015) PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015) Course Description: This course is an introduction to physics in medicine and is intended to introduce

More information

COMPARING THE RESPONSES OF TLD 100, TLD 600, TLD 700 AND TLD 400 IN MIXED NEUTRON-GAMMA FIELDS

COMPARING THE RESPONSES OF TLD 100, TLD 600, TLD 700 AND TLD 400 IN MIXED NEUTRON-GAMMA FIELDS 2015 International Nuclear Atlantic Conference - INAC 2015 São Paulo, SP, Brazil, October 4-9, 2015 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-06-9 COMPARING THE RESPONSES OF TLD

More information

PGY-1. Resident Review Session Schedule

PGY-1. Resident Review Session Schedule 1. August Simulation & Treatment 1.1. Sim Setup 1.2. Sim Techniques 1.3. 4DCT 1.4. Breath Hold / Gating 1.5. Treatment Setup 1.6. Treatment Delivery 1.7. Filming 1.7.1. Port film 1.7.2. kv 1.7.3. CBCT

More information

2. RADIOPHARMACEUTICALS UTILIZED

2. RADIOPHARMACEUTICALS UTILIZED 1. OVERVIEW AND INDICATIONS (adapted from Society of Nuclear Medicine Procedure Guideline for Thyroid Uptake Measurement, Version 3.0; reprinted from http://snmmi.files.cmsplus.com/docs/thyroid%20uptake%20measure%20v3%200.pdf,

More information

Table 1 Principal Radiation Emission Data * Disintegration. Gamma Ka 1 X-ray

Table 1 Principal Radiation Emission Data * Disintegration. Gamma Ka 1 X-ray DESCRIPTIONGeneralGlofil-125 (Sodium Iothalamate I-125 Injection) is a sterile, nonpyrogenic aqueous injection containing approximately 1 mg sodium iothalamate per ml, and 0.9 percent benzyl alcohol as

More information

RADIATION SAFETY REFRESHER TRAINING FOR AUGUSTA UNIVERSITY USERS OF RADIOACTIVE MATERIAL

RADIATION SAFETY REFRESHER TRAINING FOR AUGUSTA UNIVERSITY USERS OF RADIOACTIVE MATERIAL RADIATION SAFETY REFRESHER TRAINING FOR AUGUSTA UNIVERSITY USERS OF RADIOACTIVE MATERIAL Environmental Health and Safety Division Course Content Radiation Safety Radiation Dose Limits and Dosimetry Postings

More information

Radioactive Exposure. Abstract of Article:

Radioactive Exposure. Abstract of Article: Radioactive Exposure Abstract of Article: All ionizing radiations, at sufficiently large exposures, can cause cancer. Many, in carefully controlled exposures, are also used for cancer therapy. Ionizing

More information

Estimation of annual effective dose to the adult Egyptian population due to natural radioactive elements in ingestion of spices

Estimation of annual effective dose to the adult Egyptian population due to natural radioactive elements in ingestion of spices Available online at www.pelagiaresearchlibrary.com Advances in Applied Science Research, 2013, 4(5):350-354 ISSN: 0976-8610 CODEN (USA): AASRFC Estimation of annual effective dose to the adult Egyptian

More information

Applications of radioactivity in medicine

Applications of radioactivity in medicine Lec.3 Applications of radioactivity in medicine -Nuclear medicine (N.M) -Applications of radioactive material in medicine Nuclear Medicine:- The clinical uses of radioactivity for the diagnosis of disease.

More information

Study of the Influence of Radionuclide Biokinetic Distribution in Human Body on the Efficiency Response of Lung Counters

Study of the Influence of Radionuclide Biokinetic Distribution in Human Body on the Efficiency Response of Lung Counters Study of the nfluence of Radionuclide Biokinetic Distribution in Human Body on the Efficiency Response of Counters LU Liye 1, 2, *, CAO Qinjian 1, ZHAO Yuan 1, WE Xiaofeng 1, XAO Yunshi 1, XONG Wanchun

More information

Radiologic Units: What You Need to Know

Radiologic Units: What You Need to Know Radiologic Units: What You Need to Know TODD VAN AUKEN M.ED. RT (R)(MR) Agenda Greys, Sieverts, Coulombs per kg, & Becquerel's Conventional Units Other Concepts (LET, Q-Factor, Effective Dose, NCRP Report

More information

Ionizing Radiation. Alpha Particles CHAPTER 1

Ionizing Radiation. Alpha Particles CHAPTER 1 CHAPTER 1 Ionizing Radiation Ionizing radiation is radiation that has sufficient energy to remove electrons from atoms. In this document, it will be referred to simply as radiation. One source of radiation

More information

KEYWORDS: nuclear medicine; gamma camera; radiopharmaceutical activities.

KEYWORDS: nuclear medicine; gamma camera; radiopharmaceutical activities. Radiopharmaceutical Activities Administered for Diagnostic Procedures in Nuclear Medicine in the First Six Months of the Gamma Camera Use in the Clinical Center of Montenegro - Podgorica Nevenka Antovic

More information

Training Course on Medical Preparedness and Response for a Nuclear or Radiological Emergency Pre- Test - BASIC

Training Course on Medical Preparedness and Response for a Nuclear or Radiological Emergency Pre- Test - BASIC Training Course on Medical Preparedness and Response for a Nuclear or Radiological Emergency Pre- Test - BASIC Name Date. (dd/mm/yyyy) Circle the correct answer(s). 1. Delayed effects of radiation exposure

More information

Skyscan 1076 in vivo scanning: X-ray dosimetry

Skyscan 1076 in vivo scanning: X-ray dosimetry Skyscan 1076 in vivo scanning: X-ray dosimetry DOSIMETRY OF HIGH RESOLUTION IN VIVO RODENT MICRO-CT IMAGING WITH THE SKYSCAN 1076 An important distinction is drawn between local tissue absorbed dose in

More information

Medical Physics 4 I3 Radiation in Medicine

Medical Physics 4 I3 Radiation in Medicine Name: Date: 1. This question is about radiation dosimetry. Medical Physics 4 I3 Radiation in Medicine Define exposure. A patient is injected with a gamma ray emitter. The radiation from the source creates

More information

Cancer Risk Factors in Ontario. Other Radiation

Cancer Risk Factors in Ontario. Other Radiation Cancer Risk Factors in Ontario Other Radiation OTHer radiation risk factor/ exposure Radon-222 and decay products X-radiation, gamma radiation Cancer The context where high risks were reported Magnitude

More information

Annex V of Technical Volume 4 UNSCEAR ASSESSMENT OF THE DOSE TO THE PUBLIC

Annex V of Technical Volume 4 UNSCEAR ASSESSMENT OF THE DOSE TO THE PUBLIC Annex V of Technical Volume 4 UNSCEAR ASSESSMENT OF THE DOSE TO THE PUBLIC V 1. UNSCEAR ASSESSMENT OF EXTERNAL EXPOSURE V 1.1. External exposure during passage of the plume There were not enough environmental

More information

International Food Safety Authorities Network (INFOSAN) INFORMATION on Nuclear accidents and radioactive contamination of foods 30.

International Food Safety Authorities Network (INFOSAN) INFORMATION on Nuclear accidents and radioactive contamination of foods 30. Food and Agriculture Organization of the United Nations International Food Safety Authorities Network (INFOSAN) INFORMATION on Nuclear accidents and radioactive contamination of foods 30. March 2011 This

More information

Y Physics Radiation Measurements and Monitoring

Y Physics Radiation Measurements and Monitoring 90 Y Physics Radiation Measurements and Monitoring Mack L. Richard, MS, CHP Indiana University Medical Center Phone: (317) 274-0330 Email: mrichar@iupui.edu What type of measurements are required? Dosage

More information

MODELLING A GAMMA IRRADIATION PROCESS USING THE MONTE CARLO METHOD

MODELLING A GAMMA IRRADIATION PROCESS USING THE MONTE CARLO METHOD 2011 International Nuclear Atlantic Conference - INAC 2011 Belo Horizonte, MG, Brazil, October 24-28, 2011 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-04-5 MODELLING A GAMMA IRRADIATION

More information

Monte Carlo Modelling: a reliable and efficient tool in radiation dosimetry

Monte Carlo Modelling: a reliable and efficient tool in radiation dosimetry Monte Carlo Modelling: a reliable and efficient tool in radiation dosimetry G. Gualdrini, P. Ferrari ENEA Radiation Protection Institute, Bologna (Italy) Contribution to the Italy in Japan 2011 initiative

More information

DRAXIMAGE SODIUM IODIDE I 131 SOLUTION USP DIAGNOSTIC. For Oral Use DESCRIPTION

DRAXIMAGE SODIUM IODIDE I 131 SOLUTION USP DIAGNOSTIC. For Oral Use DESCRIPTION DRAXIMAGE SODIUM IODIDE I 131 SOLUTION USP DIAGNOSTIC For Oral Use DESCRIPTION Sodium Iodide I 131 Solution is an aqueous solution of sodium iodide I-131 for diagnostic use by oral administration. The

More information

Compact Gamma Camera for Detection of Prostate Cancer

Compact Gamma Camera for Detection of Prostate Cancer Compact Gamma Camera for Detection of Prostate Cancer Presented at: Human Interest Panel Federal Laboratory Consortium Annual Conference Nashville, Tennessee Brookhaven National Laboratory and Hybridyne

More information

ICRP: What It Does and Why Dr Jack Valentin

ICRP: What It Does and Why Dr Jack Valentin ICRP: What It Does and Why Dr Jack Valentin Scientific Secretary, ICRP International Commission on Radiological Protection ICRP: Who, why, what? The 2007 Recommendations Justification (political) optimisation

More information

Calibration of Radiation Instruments Used in Radiation Protection and Radiotherapy in Malaysia

Calibration of Radiation Instruments Used in Radiation Protection and Radiotherapy in Malaysia Abstract Calibration of Radiation Instruments Used in Radiation Protection and Radiotherapy in Malaysia Taiman Bin Kadni (taiman@mint.gov.my) Secondary Standard Dosimetry Laboratory (SSDL) Malaysian Institute

More information

Radiation Safety Information for Students in Courses given by the Nuclear Physics Group at KTH, Stockholm, Sweden

Radiation Safety Information for Students in Courses given by the Nuclear Physics Group at KTH, Stockholm, Sweden Radiation Safety Information for Students in Courses given by the Nuclear Physics Group at KTH, Stockholm, Sweden September 2006 The aim of this text is to explain some of the basic quantities and units

More information

Biological Effects of Ionizing Radiation & Commonly Used Radiation Units

Biological Effects of Ionizing Radiation & Commonly Used Radiation Units INAYA MEDICAL COLLEGE (IMC) RAD 232 - LECTURE 2 & 3 Biological Effects of Ionizing Radiation & Commonly Used Radiation Units DR. MOHAMMED MOSTAFA EMAM How does radiation injure people? - High energy radiation

More information

MONTE CARLO SIMULATIONS FOR HOMELAND SECURITY USING ANTHROPOMORPHIC PHANTOMS. A Thesis Presented to The Academic Faculty.

MONTE CARLO SIMULATIONS FOR HOMELAND SECURITY USING ANTHROPOMORPHIC PHANTOMS. A Thesis Presented to The Academic Faculty. MONTE CARLO SIMULATIONS FOR HOMELAND SECURITY USING ANTHROPOMORPHIC PHANTOMS A Thesis Presented to The Academic Faculty by Kimberly A Burns In Partial Fulfillment of the Requirements for the Degree Master

More information

Table of Contents. Introduction 3. Background 4

Table of Contents. Introduction 3. Background 4 Training manual Table of Contents Introduction 3 Background 4 What are X-rays? 4 How are X-rays Generated? 5 Primary and Scatter Radiation 6 Interactions with Matter 6 Biological Effects of Radiation 7

More information

Nuclear energy, nuclear technologies, and radiological protection Vocabulary. Part 4: Dosimetry for radiation processing

Nuclear energy, nuclear technologies, and radiological protection Vocabulary. Part 4: Dosimetry for radiation processing Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 12749-4 First edition 2015-08-15 Nuclear energy, nuclear technologies, and radiological protection Vocabulary Part 4: Dosimetry for radiation processing

More information

Using Monte Carlo Method for Evaluation of kvp & mas variation effect on Absorbed Dose in Mammography

Using Monte Carlo Method for Evaluation of kvp & mas variation effect on Absorbed Dose in Mammography Using Monte Carlo Method for Evaluation of kvp & mas variation effect on Absorbed Dose in Mammography Poster No.: C-2078 Congress: ECR 2011 Type: Authors: Keywords: DOI: Scientific Exhibit F. Salmani Rezaei,

More information

Basic radiation protection & radiobiology

Basic radiation protection & radiobiology Basic radiation protection & radiobiology By Dr. Mohsen Dashti Patient care & management 202 Wednesday, October 13, 2010 Ionizing radiation. Discussion issues Protecting the patient. Protecting the radiographer.

More information

Radiation Monitoring Instruments

Radiation Monitoring Instruments Radiation Monitoring Instruments This set of slides is based on Chapter 4 authored byg. Rajan, J. Izewska of the IAEA publication (ISBN 92-0-107304-6): Radiation Oncology Physics: A Handbook for Teachers

More information

Exposure to Background Radiation In Australia

Exposure to Background Radiation In Australia AU9816851 Exposure to Background Radiation In Australia S.B.SOLOMON, Australian Radiation Laboratory, Lower Plenty Road, Yallambie, Victoria, 3085 SUMMARY The average effective dose received by the Australian

More information

Application of the Commission's Recommendations for the Protection of People in

Application of the Commission's Recommendations for the Protection of People in ICRP Publication 127 ICRP Publication 126 ICRP Publication 125 ICRP Publication 124 ICRP Publication 123 ICRP Publication 122 ICRP Publication 121 ICRP Publication 120 ICRP 2011 Proceedings Radiological

More information

Biological Effects of Ionizing Radiation & Commonly Used Radiation Units

Biological Effects of Ionizing Radiation & Commonly Used Radiation Units INAYA MEDICAL COLLEGE (IMC) RAD 232 - LECTURE 3, 4 & 5 Biological Effects of Ionizing Radiation & Commonly Used Radiation Units DR. MOHAMMED MOSTAFA EMAM How does radiation injure people? - High energy

More information

A performance comparison of two kinds of liquid scintillation counters (LSCs) from PerkinElmer, Inc.

A performance comparison of two kinds of liquid scintillation counters (LSCs) from PerkinElmer, Inc. Institute of Nuclear and New Energy Technology(INET), Tsinghua University A performance comparison of two kinds of liquid scintillation counters (LSCs) from PerkinElmer, Inc. Xiao-gui FENG 1), Guo-hua

More information

Introduction To Nuclear Power Module 3: Understanding Radiation and Its Effects

Introduction To Nuclear Power Module 3: Understanding Radiation and Its Effects Introduction To Nuclear Power Module 3: Understanding Radiation and Its Effects Course # 9CCKN1002 Nathan Hoffman, PhD Greg Johnson, PhD, PE Phil Rutherford R.Z. Litwin (Editor) 1 Introduction To Nuclear

More information

REPORT NO. 5. background material. for the development of. radiation protection. standards. July Staff Report of the FEDERAL RADIATION COUNCIL

REPORT NO. 5. background material. for the development of. radiation protection. standards. July Staff Report of the FEDERAL RADIATION COUNCIL REPORT NO. 5 background material for the development of radiation protection standards July 1964 Staff Report of the FEDERAL RADIATION COUNCIL REPORT NO. 5 background material for the development of radiation

More information

Quality and Safety of Patient Healthcare and Personalized Medicine Using Ionizing Radiation

Quality and Safety of Patient Healthcare and Personalized Medicine Using Ionizing Radiation Quality and Safety of Patient Healthcare and Personalized Medicine Using Ionizing Radiation Ana Catarina Antunes, Mariana Baptista, Ana Belchior, Jorge Borbinha, Salvatore di Maria, Célia Fernandes, Joana

More information

A NEW USER-FRIENDLY EXTREMITY DOSIMETRY SYSTEM DESIGN, COMPARISON, AND TESTING

A NEW USER-FRIENDLY EXTREMITY DOSIMETRY SYSTEM DESIGN, COMPARISON, AND TESTING A NEW USER-FRIENDLY EXTREMITY DOSIMETRY SYSTEM DESIGN, COMPARISON, AND TESTING H. Stadtmann 1, J. Fellinger 2, K.J. Velbeck 2, C. Schmitzer 1 J.E. Rotunda 2 and E. Michler 1 1 Austrian Research Centre,

More information

A Real-Time Monte Carlo System for Internal Dose Evaluation Using an Anthropomorphic Phantom with Different Shapes of Tumors Inserted

A Real-Time Monte Carlo System for Internal Dose Evaluation Using an Anthropomorphic Phantom with Different Shapes of Tumors Inserted A Real-Time Monte Carlo System for Internal Dose Evaluation Using an Anthropomorphic Phantom with Different Shapes of Tumors Inserted J. Wu, S. J. Chang, B. J. Chang, I. J. Chen, J. H. Chiu Health Physics

More information

Chapter 17 Internal Radiation Dose of KURRI Volunteers Working at Evacuation Shelters After TEPCO s Fukushima Daiichi Nuclear Power Plant Accident

Chapter 17 Internal Radiation Dose of KURRI Volunteers Working at Evacuation Shelters After TEPCO s Fukushima Daiichi Nuclear Power Plant Accident Chapter 17 Internal Radiation Dose of KURRI Volunteers Working at Evacuation Shelters After TEPCO s Fukushima Daiichi Nuclear Power Plant Accident Yuko Kinashi, Kouta Kurihara, Keiko Fujiwara, Eiko Kakihana,

More information

Survey of patients CT radiation dose in Jiangsu Province

Survey of patients CT radiation dose in Jiangsu Province Original Article Page 1 of 6 Survey of patients CT radiation dose in Jiangsu Province Yuanyuan Zhou 1, Chunyong Yang 1, Xingjiang Cao 1, Xiang Du 1, Ningle Yu 1, Xianfeng Zhou 2, Baoli Zhu 1, Jin Wang

More information

Nuclear Regulatory Commission guidance on release of radioactive patients

Nuclear Regulatory Commission guidance on release of radioactive patients Nuclear Regulatory Commission guidance on release of radioactive patients Dawn Banghart, CHP Sr. Health Physicist Alt. Radiation Safety Officer Nuc Med Can this therapy patient be released? Lu 177 Radioactive

More information

Medical Use of Radioisotopes

Medical Use of Radioisotopes Medical Use of Radioisotopes Therapy Radioisotopes prove to be useful in the application of brachytherapy, the procedure for using temporary irradiation close to the area of disease (i.e. cancer) 10% Medical

More information

Real Time Spectrometer for thermal neutrons from Radiotherapic Accelerators

Real Time Spectrometer for thermal neutrons from Radiotherapic Accelerators Real Time Spectrometer for thermal neutrons from Radiotherapic Accelerators Aldo Mozzanica, Università degli Studi di Brescia, INFN sezione di Pavia mozzanica@bs.infn.it 2 Outlines The Boron Neutron Capture

More information

ICRP 128 ICRP ICRP ICRP 1928

ICRP 128 ICRP ICRP ICRP 1928 ICRP 1928 129 ICRP 1928 ICRP ICRP ICRP 1928 129 ICRP 129 ICRP 128 Radiological Protection in Cone Beam Computed Tomography (CBCT) Radiation Dose to Patients from Radiopharmaceuticals: A Compendium of Current

More information

Application of 3D Printing to Molecular Radiotherapy Phantoms. Nick Calvert Nuclear Medicine Group The Christie NHS Foundation Trust, Manchester

Application of 3D Printing to Molecular Radiotherapy Phantoms. Nick Calvert Nuclear Medicine Group The Christie NHS Foundation Trust, Manchester Application of 3D Printing to Molecular Radiotherapy Phantoms Nick Calvert Nuclear Medicine Group The Christie NHS Foundation Trust, Manchester Molecular Radiotherapy Radionuclide administered to patient

More information