ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

Size: px
Start display at page:

Download "ON/OFF zone valves (PN 16) AMZ 112, AMZ 113"

Transcription

1 ata sheet ON/OFF zone valves (PN 16) MZ 112, MZ 11 escription MZ 112 / 2-port valve N15-N2 MZ 112 / 2-port valve N40-N50 MZ 11 / -port valve The ON / OFF zone valves type MZ 112 and MZ 11 are typical used in connection with: omestic and commercial central heating applications omestic hot water applications Solar energy plants Priority control of hot water supply and heating (diverting function) Priority control of boiler and solid fuel installations (diverting function). The ON / OFF zone valves can be applied together with most anfoss Room Thermostats, particulary type RET 20 (single poled switch) and programmable Room Thermostats type TP 5000 / Other compatible room thermostats are available, please see www. danfoss.com/heating for details. The actuator can be controlled by a SPST or SPT switch. The limit stop switch can be used for start / stop of a fan or a circulation pump in an entirely open valve. Ordering MZ port valve / actuator N k vs (m /h) onnection R p ½ Max. p Valve 20V 082G5501 ode No R p 1 082G G bar 2 12 R p 1 ¼ 082G G552 24V 082G R p ¾ 082G G R p 1 ½ 082G G R p 2 082G G5525 MZ 11 -port valve / actuator N k vs (m /h) onnection 15.8 R p ½ Max. p Valve 20V 082G5511 ode No R p ¾ 6 bar 082G G V 082G R p 1 082G G5528 EN-SMT/SI V.H.N4.02 anfoss 11/2011 1

2 ata sheet ON / OFF Zone valves MZ 112 & MZ 11 pplication principles ON / OFF control of Radiator -, under floor heating and zone systems (night set back). -QM -QM ON / OFF control of one or more heating / surfaces. 10 Priority control of hot water supply and heating - diverting function. Priority control of boiler and solid fuel installations - diverting function. 2 V.H.N4.02 anfoss 11/2011 EN-SMT/SI

3 ata sheet ON / OFF Zone valves MZ 112 & MZ 11 Technical data ctuator Type Supply voltage Micro switch Power consumption Electrical protection class MZ 112 (20 V, N 15-2) 9. y operation 5 Open position 0 losed position MZ 112 (20 V, N 40/50) 20 V, 50 / 60 Hz 1 (1), 250 V 9 y operation 5 Open position 0 losed position lass II acc. EN Enclosure IP 44 acc. IE MZ 11 (20 V) 9. y operation 5 Open position 0 losed position Rotation time 0 sec / 90 2 sec / sec / 90 mbient temperature Humidity RH 0%... 80% Non condensed Wire 4 x 0.5 mm 2, L= 1.5 m 4 x 0.5 mm 2, L= 2 m 4 x 0.5 mm 2, L=1.5 m Type Supply voltage Micro switch Power consumption Electrical protection class Valve MZ 112 (24 V, N 15-2) 24 V, 50 Hz 1 (1), 250 V 6 y operation 1 Open position 0 losed position lass II acc. EN Enclosure IP 44 acc. IE MZ 11 (24 V) Rotation time 0 sec / sec / 90 mbient temperature Humidity RH 0%... 80% Non condensed Wire 4 x 0.5 mm 2, L= 1.5 m 4 x 0.5 mm 2, L= 1.5 m Type MZ 112, MZ 11 Medium temperature 2 10 Nominal pressure PN 16 Medium irculation water / glycolic water up to 0% Max. operating torque 8 Nm Max. p valve 6 bar Materials ody - stem Hot stamped brass uzn40pb2 Ni plated all Hot stamped brass uzn40pb2 r plated Gaskets PTFE - FPM - EPM onnection Internal thread Rp ISO 7/1 Sizing N 50 k 290 N 40 k 198 MZ 112 MZ 11 EN-SMT/SI V.H.N4.02 anfoss 11/2011

4 ata sheet ON / OFF Zone valves MZ 112 & MZ 11 Wiring MZ 112 / 11 SPST switch lack (L) lue (N) rown (L) Red (L) OPEN / PORT LOSE / PORT F1/250V L N MZ 112 / 11 SPT switch lack (L) lue (N) rown (L) Red (L) OPEN / PORT LOSE / PORT F1/250V L N Out signal OPEN (MZ 112) + (MZ 11) Out signal OPEN (MZ 112) + (MZ11)! p Fr MZ 112 / 11 SPST switch 1 lack (L) OPEN / PORT L N WRNING! y controlling electronic pump (energy saving, pressure controlled) use relay because of generating hight current peaks! 2 4 lue (N) rown (L) LOSE / PORT F1/250V Red (L) Out signal OPEN (MZ112) + (MZ11)! p Fr RELY 20V Installation positions MZ N15-N2! FORIEN! MZ 11! FORIEN! MZ N40-N50! FORIEN! 4 V.H.N4.02 anfoss 11/2011 EN-SMT/SI

5 MN ata sheet ON / OFF Zone valves MZ 112 & MZ 11 Manual control Manual control - MZ 1 12, N15-N2 Position indication Manual control - MZ 1 1 Position indication Manual control - MZ 1 12, N40, N50 Position indication 1 2 OPEN LOSE Note: When button for manual operating is in <MN> position, actuator stays in temporary position irrespective of control signal. EN-SMT/SI V.H.N4.02 anfoss 11/2011 5

6 ata sheet ON / OFF Zone valves MZ 112 & MZ 11 imensions MZ 112, N 15-2 MZ 1 12, N15-N ,2 N onnection G Kvs (m /h) Weight (kg) 15 1/2" /4" " /4" MZ MZ 112, 1 N 12, 40/50 N40, N MZ MZ ,8 60,2 9 N onnection G Kvs (m /h) Weight (kg) /2" " N onnection G Kvs (m /h) Weight (kg) 15 1/2" /4" " V.H.N4.02 anfoss 11/2011 EN-SMT/SI

7 ata sheet ON / OFF Zone valves MZ 112 & MZ 11 EN-SMT/SI V.H.N4.02 anfoss 11/2011 7

8 ata sheet ON / OFF Zone valves MZ 112 & MZ 11 8 V.H.N4.02 Produced by anfoss /S 11/2011

RLS/BP MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES. RLS 300/BP MX 600/ kw RLS 400/BP MX 800/ kw DUAL FUEL.

RLS/BP MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES. RLS 300/BP MX 600/ kw RLS 400/BP MX 800/ kw DUAL FUEL. RLS/BP MX series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above all,

More information

RL/B MZ SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL RL 300/B MZ RL 400/B MZ. 600/ kw 1000/ kw

RL/B MZ SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL RL 300/B MZ RL 400/B MZ. 600/ kw 1000/ kw RL/B MZ series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above all, more

More information

RLS /M MX SERIES

RLS /M MX SERIES The RLS/M MX series of burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above

More information

RLS /M MX SERIES

RLS /M MX SERIES RLS/M burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above all, more flexible.

More information

RLS /E MX SERIES

RLS /E MX SERIES RLS 310 610/E MX SERIES The RLS/E-MX series of burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier,

More information

RLS /E-EV MX SERIES

RLS /E-EV MX SERIES RLS 300 800/E-EV MX SERIES RLS/E-EV MX series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier,

More information

Liquid level transmitter Type AKS 41 / 41U REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Liquid level transmitter Type AKS 41 / 41U REFRIGERATION AND AIR CONDITIONING. Technical leaflet Liquid level transmitter Type AKS 41 / 41U REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3

More information

RLS/M MZ SERIES. Modulating Dual Fuel Burners FIRING RATES DUAL FUEL

RLS/M MZ SERIES. Modulating Dual Fuel Burners FIRING RATES DUAL FUEL The RLS/M MZ series of burners covers a fi ring range from 550 to 2460 kw, and they have been designed for use in hot or superheated water boilers, hot air or steam generators, diathermic oil boilers.

More information

RLS/E-EV MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES

RLS/E-EV MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES The RLS/E-EV MX series of burners covers a firing range from 350 to 2400 kw, and they have been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil

More information

TWO STAGE DUAL FUEL BURNERS

TWO STAGE DUAL FUEL BURNERS TWO STAGE DUAL FUEL BURNERS RLS SERIES 1/163 325 kw 116/232 442 kw RLS 5 145/29 581 kw RLS 7 232/465 814 kw RLS 1 349/698 1163 kw RLS 13 465/93 1395 kw The RLS series of burners covers a firing range from

More information

TECHNICAL CHARACTERISTICS BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS

TECHNICAL CHARACTERISTICS BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS LE GLNS able glands and plastic accessories Regulatory ompliance: able Glands: EN 50262; IE 62444 Metric pitch: IE/EN 60243 PG pitch: IN 40430 ouplings and cable glands: EN 61386-1 e EN 60670-1 as applicable

More information

Side Channel R ing Blower

Side Channel R ing Blower Side Channel R ing Blower ------------------------------------- INSTRUCTION MNUL ------------------------------------ RB20../ 30../ 40../ 50../ 60 / 80.. SERIES CONTENT PGE 1. SFETY REQUIREMENT... 1 2.

More information

Advanced in vitro exposure systems VITROCELL VC 10 S-TYPE SMOKING ROBOT

Advanced in vitro exposure systems VITROCELL VC 10 S-TYPE SMOKING ROBOT Advanced in vitro exposure systems VITROCELL VC 10 S-TYPE SMOKING ROBOT Platform concept conventional cigarettes e-cigarettes fast cleaning VITROCELL SMOKING ROBOT VC 10 S-TYPE Features all special requirements

More information

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...

More information

Advanced in vitro exposure systems VITROCELL VC 1 SMOKING MACHINE

Advanced in vitro exposure systems VITROCELL VC 1 SMOKING MACHINE Advanced in vitro exposure systems VITROCELL VC 1 SMOKING MACHINE Options for e-cigarettes VITROCELL VC 1 SMOKING MACHINE Manual smoking machine with high tech features square puff profiles higher puff

More information

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL 1 2 Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...

More information

RLS/M MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES. RLS 68/M MX 200/ kw RLS 120/M MX. 300/ kw RLS 160/M MX

RLS/M MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES. RLS 68/M MX 200/ kw RLS 120/M MX. 300/ kw RLS 160/M MX Low NOx Modulating Dual Fuel Burners RLS/M MX SERIES The RLS/M MX series of burners covers a fi ring range from 350 to 1840 kw, and they have been designed for use in low or medium temperature hot water

More information

Cerus P-Series General Specifications Section 15172

Cerus P-Series General Specifications Section 15172 Cerus P-Series s Section 15172 Variable Frequency Drives PART 1-GENERAL 1.01 SECTION INCLUDES A. Variable Frequency Drive(VFD) 1.02 RELATED SECTIONS A. Section 16195 1.03 REFERENCES A. NEMA250 B. EN 50178

More information

tado setup overview A compact setup guide on how to install the tado Smart Thermostat and the tado Extension Kit in different heating setups.

tado setup overview A compact setup guide on how to install the tado Smart Thermostat and the tado Extension Kit in different heating setups. tado setup overview A compact setup guide on how to install the tado Smart Thermostat and the tado Extension Kit in different heating setups. 1 Room thermostat + Boiler When the original heating setup

More information

Mechanically actuated valves

Mechanically actuated valves Mechanically actuated valves /2-5/2 spool valves with /8 NPT threaded ports Installation in any position Comprehensive range of actuations, direct or servo-piloted Special versions on request Materials

More information

Polyester distribution boxes

Polyester distribution boxes for Zone and Zone Description have been of great advantage in many industrial plants. They offer safe protection even when they are exposed to extreme environmental conditions, aggressive chemical media

More information

VIAVI IFR6000 DME Mode Signal Generator Reply Pulse Width Output Frequency Echo Reply Output Level Reply Pulse Rise and Fall Times (all pulses)

VIAVI IFR6000 DME Mode Signal Generator Reply Pulse Width Output Frequency Echo Reply Output Level Reply Pulse Rise and Fall Times (all pulses) Specification Sheet VIAVI IFR6000 Transponder/DME/TCAS Flight Line Test Set VIAVI Solutions DME Mode A 5-minute warm-up period is required for all specifications. Output Reply : 962 to 1213 MHz : Output

More information

MOTOR STARTING AUTOTRANSFORMERS

MOTOR STARTING AUTOTRANSFORMERS SCTION 5 MOTOR STARTING AUTOTRANSFORMRS Copper Wound Two Coil and Three Coil escription and Applications... 144 Copper Standard Specifications... 145 imensional rawings... 145 Copper, Three Phase, 2 Coil

More information

AC CENTRIFUGAL FORWARD CURVED FAN 133 x 190

AC CENTRIFUGAL FORWARD CURVED FAN 133 x 190 Micromotori Elettrici Svizzera Motor Type AC CENTRIFUGAL FORWARD CURVED FAN 133 x 19 Code: 3.9775 Project code: Poles Stator Impeller Type -4 V 5/6 Hz ~ 1 1 M35 Centrifugal Forward Curved Blade double

More information

Air Preparation Equipment

Air Preparation Equipment rochure ir Preparation quipment Setting a new standard for: Quality Reliability Value lobal ompatibility ilters M Series M ir Preparation quipment M -8-S-W- MOL imensions (mm, except where noted) RKT INLU

More information

Advanced in vitro exposure systems

Advanced in vitro exposure systems Advanced in vitro exposure systems VITROCELL VC 1/7 SMOKING MACHINE Features for e-cigarettes VITROCELL VC 1/7 SMOKING MACHINE Linear smoking machine with high tech features square puff profiles higher

More information

TC TC500-X...Proportional TC1000-X...Proportional TC500-D...3-Position TC1000-D...3-Position. Electric Actuator

TC TC500-X...Proportional TC1000-X...Proportional TC500-D...3-Position TC1000-D...3-Position. Electric Actuator Datasheet No.: TC500-02 TC500-X...Proportional TC000-X...Proportional TC500-D...3-Position TC000-D...3-Position Electric Actuator Suitable for valve stroke 20mm. Rating force 500N/000N TC500-X.../ TC000-X...

More information

PROBE CONDITIONING SYSTEM- P/N FOR BATCH FURNACES

PROBE CONDITIONING SYSTEM- P/N FOR BATCH FURNACES December 3, 2007 PROBE CONDITIONING SYSTEM- P/N 13011 FOR BATCH FURNACES INSTRUCTION MANUAL M4505E SSi SUPER SYSTEMS INC. 7205 Edington Drive Cincinnati, Ohio 45249 1-513- 772-0060 1-800- 666-4330 FAX

More information

3. Dimensions, weights Placement and Assembly Pressure drops Noise data Material... 14

3. Dimensions, weights Placement and Assembly Pressure drops Noise data Material... 14 These technical specifications state a row of manufactured sizes and models of smoke extraction dampers - single (further only dampers) SEDS-L. It is valid for production, designing, ordering, delivery,

More information

12 EEx d-conduit Material

12 EEx d-conduit Material 12 EEx d-conduit Conduit Fittings Conduit fittings, BMF, with female/male union Series Nominal Ordering code Weight RN2095 BMF 1 1 /2" NPT 461 557 0 0,15 BMF 2 3 461 558 0 0,20 BMF 3 1" NPT 461 559 0 0,28

More information

Chip Resistors WR 06 X 1000 F T L WW 25 M R002 F T L

Chip Resistors WR 06 X 1000 F T L WW 25 M R002 F T L How to Order R 06 1000 L ype code Size code unctional code Resistance olerance Packaging code ermination code R : iscrete 1~10MR 25 : 2512 (6432) : Normal 24 : 2 significant digits : +/- 1% : 7" reel taping

More information

Needle Valves. We deliver confidence through quality products

Needle Valves. We deliver confidence through quality products We deliver confidence through quality products INTRODUCTION NEEDLE VALVES SD range of Needle valves come in various sizes, sealing styles, end connections and stem types. They are available in bar stock

More information

LED light engines LED linear / area. Module ELA G1 SNC Modules ELA ESSENCE

LED light engines LED linear / area. Module ELA G1 SNC Modules ELA ESSENCE Module ELA G1 SNC Modules ELA ESSENCE Product description Edgelit panel for direct recessed mount and surface or suspended mount with accessories Two luminous flux range variants 2,8 or 3,8 lm For suspended

More information

GYMTOP USB PROFESSIONAL 20143

GYMTOP USB PROFESSIONAL 20143 GYMTOP USB PROFESSIONAL 20143 CONTENTS 1 x Gymtop USB 1 x CD Please note: please see PC requirements below. ABOUT THIS PRODUCT Can help develop users motor skills including planning Gymtop uses proprioceptors

More information

2YEARS. three-phase kVA. Digital voltage stabiliser Orion Plus. Standard features. Voltage stabilisation PC selectable output voltage

2YEARS. three-phase kVA. Digital voltage stabiliser Orion Plus. Standard features. Voltage stabilisation PC selectable output voltage «WARRANTY«WARRANTY«WARRANTY«WARRANTY 2YEARS Digital stabiliser Standard features Voltage stabilisation PC selectable output Independent phase control Frequency 50/60Hz ±5% Admitted load variation Up to

More information

NO: 24 / 2 NC: 24 / 2 at 0.1 Hz

NO: 24 / 2 NC: 24 / 2 at 0.1 Hz PCB Relays Safety Relay with double contacts monostable OA 621, OA 6 OA 621 OA 6 Acc. to DIN EN 020, DIN EN 618-1, DIN EN 60664-1 High switching safety because of gold plated double contacts Low rated

More information

S201-C2. Miniature Circuit Breaker - S200-1P - C - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

S201-C2. Miniature Circuit Breaker - S200-1P - C - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions. ABB Miniature Circuit Breaker - S200-1P - C - 2 ampere General Information Extended Product Type Product ID 2CDS251001R0024 EAN 40167795225 Catalog Description Long Description Miniature Circuit Breaker

More information

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type ABB Manual Motor Starter General Information Extended Product Type Product ID 1SAM250000R1008 EAN 4013614320316 Catalog Description Long Description Manual Motor Starter The manual motor starter (also

More information

BUSHINGS: GENERAL INFORMATION

BUSHINGS: GENERAL INFORMATION BUSHINGS: GENERAL INFORMATION 1.0 Electrical characteristics (Ir = rated current; Ur = rated voltage) 1.1Standard insulation levels Rated voltage Ur kv (r.m.s.) 1 3,6 12 24 36 52 One minute power frequency

More information

3.3 Pneumatic System Equipment (PSE) Contents

3.3 Pneumatic System Equipment (PSE) Contents 3.3 Pneumatic System Equipment (PSE) Contents 3.3 Central locking (PSE/CL) Models 170, 210 Page Diagnosis Function Test.............................. 11/1 Electrical Test Program Component Locations.............................

More information

Process lock Dalton. Use: Features: Door and hatches

Process lock Dalton. Use: Features: Door and hatches Process lock Dalton Use: Door and hatches Features: Small and robust Integrated with Eden High enclosure classification IP Withstands harsh enviroments Low current consumption Status information with LED

More information

CANADA SENSORS TECHNOLOGY INC.

CANADA SENSORS TECHNOLOGY INC. CANADA SENSORS TECHNOLOGY INC. Manufacturer of Advanced Technology Pressure & Level Transmitters PRESSURE TRANSMITTER PROCESS 1 HART Enabled Intrinsically Safe Model Canada Sensors intelligent transmitters

More information

Safe. Clean. Rapid. DAC UNIVERSAL cleans, lubricates and sterilizes at the touch of a button

Safe. Clean. Rapid. DAC UNIVERSAL cleans, lubricates and sterilizes at the touch of a button CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS DAC UNIVERSAL cleans, lubricates and sterilizes at the touch of a button Safe. Clean. Rapid. DAC UNIVERSAL The hygiene formula

More information

Science skills progression KS2

Science skills progression KS2 The principal focus of science teaching in lower key stage 2 is to enable pupils to broaden their scientific view of the world around them. They should do this through exploring, talking about, testing

More information

Mini UPS and Power Sensor. Power Output Cord. Power Input Port. Switch Port

Mini UPS and Power Sensor. Power Output Cord. Power Input Port. Switch Port AVTECH Mini UPS and Power Sensor AVTECH s Mini UPS and Power Sensor (MUPS) monitors the on/off state of a power source, such as main power, a UPS, surge protector or standard wall outlet, and also provides

More information

Exchangeable Thermocouple Probes

Exchangeable Thermocouple Probes 106 Exchangeable Thermocouple Probes For each application, ebro provides the right thermometer and also offers a wide selection of precise and robust probes for the following thermometers: TTX 120 (see

More information

MULTISMOKEDAMPER MSD EN121018

MULTISMOKEDAMPER MSD EN121018 MULTISMOKEDAMPER MSD EN11018 ALNORSyst emywent yl acj isp.zo. o. Al ej akr akowska10,0555wol amr okowska t el.7374000,f ax.7374004 www. al nor. com. pl These technical specifications state a row of manufactured

More information

Hydrolysis Unit B-411 / E-416 Technical data sheet

Hydrolysis Unit B-411 / E-416 Technical data sheet Hydrolysis Unit B-4 / E-46 Technical data sheet The Hydrolysis Unit B-4 and E-46 ensure safe and fast acid hydrolysis for total fat content determination handling four or six samples simultaneously. The

More information

ATyS D10 & D20. Notice d utilisation - Operating instructions AFFICHEURS DÉPORTÉS - REMOTE INTERFACES MAKE YOUR BUSINESS SAFE

ATyS D10 & D20. Notice d utilisation - Operating instructions AFFICHEURS DÉPORTÉS - REMOTE INTERFACES MAKE YOUR BUSINESS SAFE AFFICHEURS DÉPORTÉS - REMOTE INTERFACES ATyS D10 & D20 Notice d utilisation - Operating instructions F GB MAKE YOUR BUSINESS SAFE SOCOMEC GROUP SWITCHING PROTECTION & UPS F Sommaire PRÉSENTATION GÉNÉRALE

More information

3.1 Pneumatic System Equipment (PSE) Contents

3.1 Pneumatic System Equipment (PSE) Contents 3.1 Pneumatic System Equipment (PSE) Contents 3.1 Remote Trunk Release (PSE/RTR) Model 140 Page Diagnosis Function Test.............................. 11/1 Electrical Test Program Preparation for Test refer

More information

SYSTEM RANGE DOMESTIC RANGE

SYSTEM RANGE DOMESTIC RANGE CONTROL - SYSTEM WHITE ONE-WAYSWITCHES GW 20 571-16AX 1P - GW 20 572-16AX 1P - Backlit GW 20 583-16AX 1P - GW 20 503 2P - 16AX - GW 20 504 2P - 16AX - Backlit - GW 20 584 2P - 16AX - GW 20 005 2P - 10AX

More information

RLS Series Two Stage Dual Fuel Burners

RLS Series Two Stage Dual Fuel Burners Technical Data Leaflet Dual Fuel TS0040UK02 RLS Series Two Stage Dual Fuel Burners RLS 28 100/163 325 kw RLS 38 116/232 442 kw RLS 50 145/290 581 kw RLS 70 232/465 814 kw RLS 100 349/698 1163 kw RLS 130

More information

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type ABB MS132-6.3 Manual Motor Starter General Information Extended Product Type Product ID MS132-6.3 1SAM350000R1009 EAN 4013614400094 Catalog Description Long Description MS132-6.3 Manual Motor Starter The

More information

MINISTAR DIGITAL AND CONTROL /// The new compact stirrers

MINISTAR DIGITAL AND CONTROL /// The new compact stirrers 30 /// OVERHEAD STIRRERS OVERHEAD STIRRERS MICROSTARS 31 IKA offers the ideal overhead stirrer for your stirring and mixing tasks in the lab for low to high viscosities. IKA overhead stirrers effortlessly

More information

Keylock switches for PCB

Keylock switches for PCB lock switch for PCB General data lock switch for PCB mounting. Matching with the RS 76 full-travel keyswitch and the RF 15 and RF 19 short-travel keyswitch. Content lock switch IP5, MICROMEC - 18 lock

More information

NOE LOBBY RANGE NOE LOBBY C - 1/2 hrs CMV/Collective extraction units Flow rate 400 to m 3 /h COLLECTIVE VENTILATION

NOE LOBBY RANGE NOE LOBBY C - 1/2 hrs CMV/Collective extraction units Flow rate 400 to m 3 /h COLLECTIVE VENTILATION COLLECTIVE VENTILATION NOE LOBBY RANGE NOE LOBBY 4 4 C - 1/2 hrs CMV/Collective extraction units Flow rate 4 to 114 m 3 /h 4 4 COLLECTIVE VENTILATION Ventilation unit PULLEY/BELT TRANSMISSION 4 to 114

More information

The Phalanx. Featuring Evolv DNA250 Technology. ***Keep Out of reach of children. This device is for persons 18yrs of age or older ***

The Phalanx. Featuring Evolv DNA250 Technology. ***Keep Out of reach of children. This device is for persons 18yrs of age or older *** The Phalanx Featuring Evolv DNA250 Technology ***Keep Out of reach of children. This device is for persons 18yrs of age or older *** Congratulations on your purchase of the Phalanx DNA250 temperature protected

More information

Exchangeable Thermocouple Probes

Exchangeable Thermocouple Probes 118 Temperature Exchangeable Thermocouple Probes Exchangeable Thermocouple Probes For each application, ebro provides the right thermometer and also offers a wide selection of precise and robust probes

More information

Datasheet BR Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors

Datasheet BR Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors Datasheet BR Series /CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors NEW Compared to traditional fuse installation, the /CSA C22.2 No.5-02, UL1077/CSA

More information

needle valves 3700, 3800, 3900 Series Forged Body, Integral Bonnet Needle Valves

needle valves 3700, 3800, 3900 Series Forged Body, Integral Bonnet Needle Valves orged ody, Integral onnet Needle Valves Offered in four different body materials, this group of valves can handle a wide range of general purpose liquid and gas applications. Six types of stem tips are

More information

Armstrong IVS 102 Drive Specification

Armstrong IVS 102 Drive Specification Armstrong IVS 102 Drive Specification Part I: General Description 1. This specification covers complete variable frequency drives (VFDs) designated on the drawing schedules to be variable speed. All standard

More information

Vibration Limit Switch liquiphant S FTL 70, FTL 71

Vibration Limit Switch liquiphant S FTL 70, FTL 71 Technical Information TI 354F/00/en Vibration Limit Switch liquiphant S FTL 70, FTL 71 Level limit switch for all liquids. Version for high medium temperatures. Suitable for use in explosion hazardous

More information

S202M-K2UC. Miniature Circuit Breaker - S200MUC - 2P - K - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

S202M-K2UC. Miniature Circuit Breaker - S200MUC - 2P - K - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions. ABB Miniature Circuit Breaker - S00MUC - P - K - ampere General Information Extended Product Type Product ID S0M-KUC CDS7061R077 EAN 4013614433146 Catalog Description Long Description Miniature Circuit

More information

NO: 24 / 2 NC: 24 / 2 at 0.1 Hz

NO: 24 / 2 NC: 24 / 2 at 0.1 Hz PCB Relays Safety Relay with double contacts OA 621, OA 6 According to DIN EN 618-1, DIN EN 618-3 With forcibly guided contacts High switching safety because of gold plated double contacts Clearance and

More information

General Information. Ordering. Popular Downloads. Dimensions. Products Low Voltage Products and Systems Circuit Breakers Manual Motor Starters

General Information. Ordering. Popular Downloads. Dimensions. Products Low Voltage Products and Systems Circuit Breakers Manual Motor Starters MS132-1.6-HKF1-11 Products Low Voltage Products and Systems Circuit Breakers Manual Motor Starters Products Low Voltage Products and Systems Control Products Manual Motor Starters Manual Motor Starters

More information

Compressor Accessories

Compressor Accessories Compressor Accessories Series 11 Superior quality for superior performance COMPRESSOR OIL Description MINERAL 11.1100 1 litre container 11.1400 4 litre container SYNTHETIC 11.1200 1 litre container 11.1500

More information

Liquid ring vacuum pumps single-stage

Liquid ring vacuum pumps single-stage Liquid ring vacuum pumps single-stage LOH 20103, LOH 20107 Pressure range: Suction volume flow: 150 to 1013 mbar 7 to 58 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum pumps are displacement pumps

More information

Bosch BOVA Split System Heat Pump

Bosch BOVA Split System Heat Pump Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications Product Specifications Split System Heat Pump Up to 18 SEER 2-3-4-5 Ton Capacity R410A

More information

2D-LC as an Automated Desalting Tool for MSD Analysis

2D-LC as an Automated Desalting Tool for MSD Analysis 2D-LC as an Automated Desalting Tool for MSD Analysis Direct Mass Selective Detection of a Pharmaceutical Peptide from an MS-Incompatible USP Method Application Note Biologics and Biosimilars Author Sonja

More information

Barlows Primary School Science Curriculum Content Key Stage 1 and

Barlows Primary School Science Curriculum Content Key Stage 1 and Science Curriculum Content Key Stage 1 and 2 2017-2018 Curriculum Content Year 1 Curriculum. The content for Year 1 is detailed below: During year 1, pupils should be taught to use the following practical

More information

In-Line Check Valves. Features. Valves. Working Pressures to: Flow Ranges to:

In-Line Check Valves. Features. Valves. Working Pressures to: Flow Ranges to: Valves In-Line Check Valves Working Pressures to: Flow Ranges to: 5700 psi/393 bar 200 gpm 757 lpm Features Steel constructed check valves are compatible with all non-corrosive liquids. Valves contain

More information

Plant - 1. Plant - 2. Plant - 3

Plant - 1. Plant - 2. Plant - 3 Plant - Plant - Plant - Declaration of Conformity We Lubi Electricals Limited hereby declare under our responsibility that the products LSS Series Centrifugal Pump is in conformity to the following CE

More information

J350, J360 and J370 PLUMBING PARTS CATALOG

J350, J360 and J370 PLUMBING PARTS CATALOG PREMIUM J0, J0 and J0 PLUMBING PARTS CATALOG PUMP Pump/Motor # * 0 * 00- HOUSING: FRONT 00-0 O-RING: FRONT HOUSING 00- IMPELLER:. DIA 00-0 PUMP: SEAL ASSY / VITON 00- HOUSING: REAR BRACKET 00-0 MOTOR:.HP

More information

S201-Z2. Miniature Circuit Breaker - S200-1P - Z - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

S201-Z2. Miniature Circuit Breaker - S200-1P - Z - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions. ABB Miniature Circuit Breaker - S200-1P - Z - 2 ampere General Information Extended Product Type Product ID S201-Z2 2CDS251001R0278 EAN 40167795054 Catalog Description Long Description Miniature Circuit

More information

3.5 Pneumatic System Equipment (PSE) Contents

3.5 Pneumatic System Equipment (PSE) Contents 3.5 Pneumatic System Equipment (PSE) Contents 3.5 PSE Control Module (PSE) Models 129, 140, 170 as of M.Y. 1998 Page Diagnosis Function Test............................... 11/1 Diagnostic Trouble Code

More information

Original Chiksan Swivel Joints

Original Chiksan Swivel Joints Original hiksan Swivel Joints Steamlined bore minimizes flow restrictions Smooth, round bore design minimizes turbulence and pressure drop, Longsweep and TripleStep swivel joints have extralong radius

More information

Advanced Research Systems, Inc.

Advanced Research Systems, Inc. 4/17/01 Page 1 Huber Goniometer Interface 6.5K to 800K Closed Cycle Cryostat DESCRIPTION The DE-202G has been designed for applications requiring movement of the refrigerator, specifically for goniometers.

More information

Needle Valves Catalog 4110-NV December 2010

Needle Valves Catalog 4110-NV December 2010 Needle Valves Catalog 4110-NV December 2010 Series Needle Valves Catalog 4110-NV Introduction Parker Series nion onnet Valves have been engineered for use at pressures up to 6,000 (414 bar) and temperatures

More information

INTEGRAL-BONNET NEEDLE VALVES H-300 SERIES

INTEGRAL-BONNET NEEDLE VALVES H-300 SERIES INTEGRAL-BONNET NEEDLE VALVES SERIES INTEGRAL-BONNET NEEDLE VALVES SERIES FEATURES n Straight and angle pattern n Stainless Steel and Brass construction n MAWP 5000 psi (345 bar) n MAWT 446 F (230 C) n

More information

Plant, components and devices for very high and high pressures (7000 bar and over)

Plant, components and devices for very high and high pressures (7000 bar and over) Plant, components and devices for very high and high pressures (7000 bar and over) VALVES AND FITTINGS UP TO 1035 BAR MATERIALS All fittings are manufactured from EN 1.4404 / AISI 316L stainless steel

More information

2014 National Curriculum Science Band 1

2014 National Curriculum Science Band 1 2014 National Curriculum Science Band 1 ask simple questions and recognise that they can be answered in different ways (Year 1 variety of common animals including fish, amphibians, reptiles, birds and

More information

Misc: Interchange Coupling

Misc: Interchange Coupling Wing Style Interchange Coupling Misc: Interchange Coupling Series: W Interchange: Parker 6100 - Seals: Nitrile - Threaded sleeve allows connection/disconnection under pressure - Coupler: brass material

More information

SPARE PARTS CATALOGUE ERSATZTEILKATALOG CATALOGUE PIECES DETACHEES CATALOGO PARTI RICAMBIO CATALOGO DE PIEZAS DE RECAMBIO CATALOGO PECAS

SPARE PARTS CATALOGUE ERSATZTEILKATALOG CATALOGUE PIECES DETACHEES CATALOGO PARTI RICAMBIO CATALOGO DE PIEZAS DE RECAMBIO CATALOGO PECAS ELETTROBAR SPARE PARTS CATALOGUE ERSATZTEILKATALOG CATALOGUE PIECES DETACHEES CATALOGO PARTI RICAMBIO CATALOGO DE PIEZAS DE RECAMBIO CATALOGO PECAS, DE REPOSICAO, FAST M FAST T 0-0-009 0 9 9 0 9 FAST M-T

More information

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER New Standard for Clinical Impedance The GSI TympStar Pro is setting the clinical standard for performing a full

More information

MS MS Manual Motor Starter. Generell informasjon. Ordering. Popular Downloads. Dimensions. Technical MS Extended Product Type

MS MS Manual Motor Starter. Generell informasjon. Ordering. Popular Downloads. Dimensions. Technical MS Extended Product Type ABB Manual Motor Starter Generell informasjon Extended Product Type Product ID 1SAM451000R1015 EAN 401614486098 Catalog Description Long Description Manual Motor Starter MS165 is a compact and powerful

More information

ORIFICE FLOW METERS WITH CHAMBERS MEASURING RINGS

ORIFICE FLOW METERS WITH CHAMBERS MEASURING RINGS Bulletin E79 rev0 02/03/03 ORIFICE FLOW METERS WITH CHAMBERS MEASURING RINGS POP-U-S SERIES FEATURES UNI PN6 flanges: iron Chamber measuring rings: iron Disc: AISI30 Max. operating temperature: 00 C Max.

More information

3/4" NPT 3080 MF 185-3/4-US 1" NPT 3080 MF US

3/4 NPT 3080 MF 185-3/4-US 1 NPT 3080 MF US Port size Recommended flow Page No. (l/min) 1/8" NPT 125 MF 007-1/8-US 111-112 1/4" NPT 125 MF 007-1/4-US 1/8" NPT 200 MF 012-1/8-US 113-114 1/4" NPT 200 MF 012-1/4-US 3/8" NPT 200 MF 012-3/8-US 3/8" NPT

More information

Flow - diaphragm / limiter

Flow - diaphragm / limiter GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 () 942-9383 - Fax - 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Flow - diaphragm / limiter System Flow Diaphragm limiter Nominal

More information

If you gave any of the following conditions, you must consult your doctor before using your Confidence Vibration Plate Power Plus

If you gave any of the following conditions, you must consult your doctor before using your Confidence Vibration Plate Power Plus SAFETY TIPS Do not use your Confidence Vibration Plate Power Plus with wet hands. Always turn off the power at the mains socket after use. Not to be used by pregnant woman. DO NOT drink alcohol and then

More information

LMT-Goniophotometer GO-H 1400 Goniophotometer System for Measurement of Automotive Lamps

LMT-Goniophotometer GO-H 1400 Goniophotometer System for Measurement of Automotive Lamps LMT-Goniophotometer GO-H 1400 Goniophotometer System for Measurement of Automotive Lamps Description and Technical Specification of the Equipment List of Contents: 0 Introduction...- 3-0.1 Principle...-

More information

Mounting and Wiring VMA1200 Series Controllers

Mounting and Wiring VMA1200 Series Controllers Technical Bulletin Issue Date July 1, 2003 Mounting and Wiring VMA1200 Series Controllers Mounting and Wiring VMA1200 Series Controllers...2 Introduction... 2 Key Concepts... 3 VMA Position and Orientation...

More information

WNK5 Series High Precision Pressure Transmitter

WNK5 Series High Precision Pressure Transmitter WNK5 Series High Precision Pressure Transmitter WNK5 series pressure transmitter is the high performance pressure transmitters provided by nhui WNK Electronic Engineering Co., Ltd. It transforms the physical

More information

12 series (Pneufit) Push-in fittings

12 series (Pneufit) Push-in fittings > > Port size: Ø /8... /2, Ø 4... 2 mm tube size, SP and NPT threads > > Very compact units > > asy tube insertion for rapid assembly of pneumatic circuits > > Positive tube anchorage > > ll taper threads

More information

Class 3. Year A. Autumn Term Spring Term Summer term Invaders and Settlers (Saxons, Vikings and Romans) Science Year 3 Magnets and friction

Class 3. Year A. Autumn Term Spring Term Summer term Invaders and Settlers (Saxons, Vikings and Romans) Science Year 3 Magnets and friction Class 3 Year A Autumn Term Spring Term Summer term Invaders and Settlers (Saxons, Vikings and Romans) Tomb Raiders (Egyptians) Fantastic Fenland Year 3 Magnets and friction Year 4 Sound Year 3 Plants compare

More information

Central Institute of Plastics Engineering & Technology (CIPET), SP- 1298, Sitapura Industrial Area, Phase III, Tonk Road, Jaipur, Rajasthan

Central Institute of Plastics Engineering & Technology (CIPET), SP- 1298, Sitapura Industrial Area, Phase III, Tonk Road, Jaipur, Rajasthan Certificate Number TC-7082 Page 1 of 14 CHEMICAL TESTING I. PLASTIC & RESINS 1. Resin, Plastic & Polymers, Raw material, Plastic Films Resistance to Sulphuric Acid Vicat Softening Temperature IS 12235-2004

More information

3.5 Pneumatic System Equipment (PSE) Contents

3.5 Pneumatic System Equipment (PSE) Contents 3.5 Pneumatic System Equipment (PSE) Contents 3.5 Remote Trunk Release (PSE/RTR) Models 129, 140 as of M.Y. 1998 Page Diagnosis Function Test.............................. 11/1 Electrical Test Program

More information

General Information. Ordering. Popular Downloads. Dimensions. Technical

General Information. Ordering. Popular Downloads. Dimensions. Technical S201M-B6 Products Low Voltage Products and Systems Modular DIN Rail Products Miniature Circuit Breakers MCBs General Information Extended Product Type: S201M-B6 Product ID: 2CDS271001R0065 EAN: 4016779549424

More information

PROFIBUS Products Overview P PROFIBUS Converter/Repeater P PROFIBUS Gateway P6-3-1

PROFIBUS Products Overview P PROFIBUS Converter/Repeater P PROFIBUS Gateway P6-3-1 .1. Overview P-1-1.2. PROFIBUS Converter/Repeater P-2-1.3. PROFIBUS Gateway P-3-1.4. PROFIBUS Remote I/O Modules P-4-1.5. PROFIBUS I/O Unit P-5-1 Overview.1. Overview PROFIBUS (Process Field Bus) is a

More information

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager Quick Start Guide Step 1. Calibrate the Q-TOF LC/MS for low m/z ratios 2 Step 2. Set up a Flow Injection Analysis (FIA) method for

More information