Vitamin Testing APPLICATIONS GUIDE

Size: px
Start display at page:

Download "Vitamin Testing APPLICATIONS GUIDE"

Transcription

1 Vitamin Testing APPLICATIONS GUIDE

2 Vitamins play an essential role in human health and wellness. While essential, many vitamins cannot be synthesized within the body and must be obtained externally, most commonly from food. Due to poverty, lack of awareness, a person s health, and other factors, many people do not have healthy levels of vitamins in their body and suffer physical and cognitive consequences as a result. Phenomenex strives to continually improve the field of vitamin research testing by offering solutions that improve medical care and increase lab efficiency. Our goal is provide solutions that are: Accurate High-Throughput Reproducible Low Cost 2 For Research Use Only. Not for use in diagnostic procedures. Phenomenex 213 Inc. All rights reserved.

3 Improve Your Vitamin Analysis Applications Vitamin B 1 from Whole Blood: Thiamine Diphosphate (TDP) Vitamin B 1 from Plasma: Thiamine Monophosphate (TMP) and Thiamine Vitamin B Vitamin B OH-Vitamin D 2 and D OH-Vitamin D 3 and 3-epi-25-OH-Vitamin D HPLC Columns Kinetex Core-Shell HPLC/UHPLC Columns...16 Gemini High ph HPLC Columns...17 Sample Preparation Solutions Impact Protein Precipitation Plates...18 Phree Phospholipid Removal Solutions...19 Strata -X Polymeric Solid Phase Extraction (SPE)...2 Technical Support PhenoLogix SM : Your Analytical Support Laboratory

4 Vitamin B 1 from Whole Blood: Thiamine Diphosphate (TDP) Thiamine Diphosphate (TDP) concentration is a useful index for determining thiamine deficiency. Samples are commonly obtained from whole blood because approximately 9 % of total thiamine in blood is in the red blood cells. Deficiency can lead to diseases such as Beriberi and optic neuropathy. Vitamin B 1 Method Highlights Total run time under 4 min Analytical measurement range: 4 nmol/l Good linearity: R 2 =.9991 N NH 2 N + N S O OH P O OH O P OH O Sample Preparation 1. Collect: venous blood into EDTA or heparin containing tubes. 2. Freeze: sample immediately at -7 C or -2 C for up to 7 days. 3. Add: 5 µl of 1 % TCA to 5 µl thawed hemolysates, water blank, calibrators, and controls to precipitate proteins. 4. Vortex: 15 seconds and leave standing on rack for 15 minutes at room temperature. 5. Centrifuge: 14, rpm for 6 minutes at room temperature. Note: The relative centrifugal force (RCF) = 16, g. 6. Transfer: 5 µl supernatant into a glass tube. i. Wash twice with methyl-tert-butyl ether (75 µl) to remove TCA. ii. Vortex for 15 seconds. iii. Centrifuge the tubes at 3,5 rpm for 3 minutes. iv. Remove the tubes and discard the top organic layer. v. Repeat once. 7. Transfer: 5 µl of extract to an autosampler injection vial. 8. Add: 5 µl of water. 9. Add: 5 µl of derivatizing reagent. 1. Vortex: 15 seconds and place the vial on the autosampler at RT. Thiamine Diphosphate 11. Inject: 2 µl of prepared sample. *Derivatizing reagent: Potassium ferricyanide [K 3 Fe(CN) 6 ] was prepared as the following: Dissolve 6 mg of K 3 Fe(CN) 6 in 15 ml 15 % sodium hydroxide solution. Prepare fresh daily. 4

5 Vitamin B 1 from Whole Blood: Thiamine Diphosphate (TDP) (cont d) LC/MS/MS Method Multi-standards of TDP (-4 nmol/l) injected after sample cleanup mau Column: Gemini 5 µm C18 Dimensions: 5 x 4.6 mm Part No.: B-4435-B Mobile Phase: A: 25 mm Disodium hydrogen phosphate, 1 % Methanol, ph 7. B: 25 mm Disodium hydrogen phosphate, 7 % Methanol, ph 7. Gradient: Time (min) % B Flow Rate: 1. ml/min Detection: Fluorescence. Excitation: 375 nm; Emission: 435 nm Sample: TDP (thiamine diphosphate) App ID min Standard curve of TDP (Whole blood), 4 nmol/l 9 8 Peak area y =.1969x R 2 = TDP Concentration (nmol/l) App ID 288 Statistic analysis of ten consecutive injections of whole blood sample spiked with TDP and injected after sample cleanup Data summary Whole blood spiked with TDP and injected after sample cleanup Seq. No. RT Area Peak Height Mean STDV CV (%) Questions or Requests? Contact ClinicalResearch@phenomenex.com for questions on applications or to request additional applications. 5

6 Vitamin B 1 from Plasma: Thiamine Monophosphate (TMP) and Thiamine Total Thiamine reflects the measurement of Thiamine (Vitamin B 1 ) and Thiamine Monophosphate (TMP). Method Highlights Vitamin B 1 Excellent linearity. TMP R 2 = Thiamine R 2 =.9986 Sample Preparation 1. Add: 4 µl of methanol to a well of an Impact Protein Precipitation Plate. 2. Add: 1 µl plasma to the well. Mix 3 times with pipette tip (or vortex the whole plate briefly). 3. Wait: 5 minutes. 4. Filter: Under vacuum (5 Hg) for 5 minutes. Ensure that a collection plate is positioned underneath the Impact Protein Precipitation Plate. 5. Transfer: 5 µl to an autosampler vial (or leave sample in collection plate). 6. Add: 1 µl water and 25 µl of derivatizing reagent*. 7. Cover: vial with lid (or collection plate with sealing mat). 8. Vortex: 15 seconds. 9. Put: vial or collection plate into an autosampler. OH O N P OH S O N N NH 2 Thiamine Monophosphate All conditions are at room temperature (RT). *Derivatizing reagent: Potassium ferricyanide [K 3 Fe(CN) 6 ] was prepared as the following: Dissolve 6 mg of K 3 Fe(CN) 6 in 15 ml 15 % sodium hydroxide solution. Prepare fresh daily. LC/MS/MS Method Column: Kinetex 5 µm C18 Dimensions: 1 x 4.6 mm Part No.: D-461-E Mobile Phase: A: 25 mm Disodium hydrogen phosphate, 1 % Methanol, ph 7. B: 25 mm Disodium hydrogen phosphate, 7 % Methanol, ph 7. Gradient: Time (min) % B Flow Rate: 1 ml/min Temperature: 25 C Backpressure: 15 bar Detection: Fluorescence Detector Excitation: 375 nm; Emission: 435 nm Sample: 1. TMP (Thiamine monophospate) 2. Thiamine 2 nmol/l filtered by an Impact Protein Precipitation Plate mau App ID min

7 Vitamin B 1 from Plasma: Thiamine Monophosphate (TMP) and Thiamine (cont d) 5 nmol/l filtered by an Impact Protein Precipitation Plate mau App ID min Standard Curve of TMP Filtered by an Impact Protein Precipitation Plate 35 3 Peak area y =.1434x -.36 R 2 = TMP Concentration (nmol/l) App ID 2876 Data summary Plasma spiked with TMP Plasma spiked with Thiamine Seq. No. RT Area RT Area Mean STDV CV (%) Questions or Requests? Contact ClinicalResearch@phenomenex.com for questions on applications or to request additional applications. 7

8 Vitamin B 3 Vitamin B 3, also known as Niacin or Nicotinic Acid is an important part of the human diet. A deficiency of Vitamin B 3 leads to pellagra, which can affect the skin and cause cognitive problems, amongst other symptoms. Method Highlights Fast sample prep using Impact Protein Precipitation Plates Fast run time of under 4 minutes N O Vitamin B 3 OH SAMPLE PREPARATION 1. Place: Impact plate onto a suitable 96-well sample manifold or rotor. 2. Dispense: 3 µl acetonitrile into the wells of the Impact plate. 3. Add: 1 µl of plasma/serum samples to each well of the Impact plate. 4. Mix: 3 times with a pipette tip. 5. Vacuum: to filter the sample and collect the purified filtrate. Ensure that a collection plate is positioned underneath the Impact plate. LC/MS/MS METHOD LC/MS/MS Chromatogram of Nicotinamide and Nicotinic Acid at 1 ng/ml 3.6e e5 Intensity, cps 3.2e5 3e5 2.8e5 2.6e5 2.4e5 2.2e5 2e5 1.8e5 1.6e5 1.4e5 Column: Gemini 3 µm C18 Dimensions: 1 x 4.6 mm Part No.: D-4439-E Mobile Phase: A:.1 % Formic acid in water B: Methanol Gradient: Time (min) % B Flow Rate:.6 ml/min Detection: Electrospray Mass Spec (ESMS) Detector: AB SCIEX API 4 Sample: 1. Nicotinamide 2. Nicotinic Acid 2 1.2e5 1e5 8e4 6e4 4.e4 2.e min App ID 299 8

9 Vitamin B 3 (cont d) LC/MS/MS Chromatogram of Nicotinamide and Nicotinic Acid at 1 ng/ml 1 8 Intensity, cps Column: Gemini 3 µm C18 Dimensions: 1 x 4.6 mm Part No.: D-4439-E Mobile Phase: A:.1 % Formic acid in water B: Methanol Gradient: Time (min) % B Flow Rate:.6 ml/min Detection: Electrospray Mass Spec (ESMS) Detector: AB SCIEX API 4 Sample: 1. Nicotinamide 2. Nicotinic Acid App ID min Nicotinic Acid Standard Curve, 2-2 ng/ml 1.5e6 1.4e6 1.3e6 1.2e6 1.1e6 1.e6 R 2 =.9996 Area, counts 9.e5 8.e5 7.e5 6.e5 MRM Transitions Used for Data Analysis Peak Name MRM Channel Nicotinamide Nicotinic acid e5 4.e5 3.e5 2.e5 1.e5. App ID min Concentration, ng/ml 9

10 Vitamin B 6 Vitamin B 6 currently refers to six biologically interconvertible 3-hydroxy-2- methylpyridine compounds: pyridoxal (PL), pyridoxine (PN), pyridoxamine (PM), and their respective 5 -phosphate (PLP, PNP, and PMP). Of these compounds, PLP is the primary biologically active form of vitamin B 6. HO O N HO OH O P O Method Highlights Vitamin B 6 Gemini NX-C18 HPLC columns provide baseline separation of PLP, 4-PA and PL Accurately quantitate PLP and 4-PA Sample Preparation 1. Thaw patient plasma samples and sera/plasma spiked calibrators or pre-manufactured calibration standards and controls at ambient temperature. Protect from light. 2. Pipette 4 μl of the blank (Water), calibration standards, controls and plasma specimens into the appropriate labeled 1.5 ml Eppendorf microcentrifuge tubes. i. Briefly vortex the calibrators and controls immediately prior to sampling. ii. Mix the plasma samples by gentle inversion immediately prior to sampling. iii. Protect the tubes from light. 3. Add 3 μl of 25 mg/ml semicarbazide/glycine solution in rapid succession into all the tubes containing samples; cap the tubes, vortex for 15 seconds. 4. Incubate in the dark at room temperature for 3 minutes. 5. Uncap the tubes; add 5 μl of 2 % meta-phosphoric acid to the controls and patient samples. 6. Recap the tubes and vortex for 3 seconds at room temperature. 7. Centrifuge for 5 minutes at 14, rpm. Note: The relative centrifugal force (RCF)=16, g. 8. Transfer 35 μl of supernatant to a 2 ml amber vial. 9. Cover the vial with lid and place in the autosampler (RT). 1. Inject 3 µl. 1

11 Vitamin B 6 (cont d) HPLC Analysis Sample chromatogram of semicarbazide derivatized PLP and PL mau Column: Gemini NX-C18 3 µm Dimensions: 1 x 4.6 mm Part No.: D-4453-E Guard: SecurityGuard Cartridge C18, 4 x 3. mm ID Part No.: AJ-8368 Mobile Phase: A: 2 mm Sodium phosphate and 1. ml Acetic acid in DI water; ph = ~6.; no ph adjustment. B: Acetonitrile/Methanol (7:3) Gradient: Time (min) % B Flow Rate: 1 ml/min Injection Volume: 3 µl Temperature: 35 C Detection: Fluorescence: Ex 36; Em 45 Sample: 1. PLP (Pyridoxal 5 -Phosphate) 2. PA (4-pyridoxic acid) 3. PL (Pyridoxal) 6 App ID min Human Serum PLP Standard Curve Example Standard Curve from 6.25 nmol/l to 2 nmol/l for PLP in Human Serum (external standard method) y = x R 2 =.9999 Peak Area 8 6 Questions or Requests? Contact ClinicalResearch@phenomenex.com for questions on applications or to request additional applications PLP Concentration in Human Serum (nmol/l) App ID

12 25-OH-Vitamin D 2 and D 3 Vitamin D is recognized as an essential nutrient for intestinal absorption of calcium and phosphate and for promoting bone resorption and formation. Deficiency can lead to bone diseases such as rickets and osteomalacia. Vitamin D levels are measured by the total serum concentrations of the two common forms of 25-OH-Vitamin D, which are 25-OH D 2 and 25-OH D 3. H Method Highlights Customer-submitted patient sample run on a multi-channel system HO Vitamin D 2 ergocalciferol 4-5 µl injection volume Sample Preparation 1. Add: 5 µl of precipitating reagent containing internal standard to a 1.5 ml centrifuge tube. 2. Pipette: 1 µl of serum into a centrifuge tube. 3. Vortex: 2 3 seconds. 4. Inspect: each tube to ensure no unmixed sample remains in the bottom of the tube. i. A homogeneous mixture is critical. ii. 5. Centrifuge: 15 minutes at 13, rpm. If unmixed sample remains at the bottom of the tube, dislodge by inverting and tapping, then re-vortex. 6. Transfer: supernatant into sample vial without disturbing the pellet. Vitamin D 3 cholecalciferol TIP: Consider Impact for high-throughput protein precipitation. See 12

13 25-OH-Vitamin D 2 and D 3 (cont d) LC/MS/MS Analysis Analyte Q1 Q3 25-OH D OH D OH D3-d Patient sample run on a multi-channel system Intensity, cps Intensity, cps 1.14e4 1.e e4 1.4e4 1.2e4 1.e OH D2 25-OH D3 2 1 Column: Kinetex 2.6 µm C18 Dimensions: 5 x 4.6 mm Part No.: B-4462-E Mobile Phase: A:.5 % Formic acid in Water B: 5 mm Ammonium acetate with.1 % Formic acid in Methanol % B Gradient: Time (min) Flow Rate: 1 ml/min Temperature 35 ºC Detection: Mass Spectrometer (MS) Detector: AB SCIEX API 4 Sample: Hydroxyvitamin D2 (25-OH D2) Hydroxyvitamin D3 (25-OH D3) Hydroxyvitamin D3-d6 (25-OH D3-d6) min min 6.e4 5.e4 25-OH D3-d6 (IS) 3 Intensity, cps 4.e4 3.e4 2.e4 1.e min App ID View our technical note on 25-OH-Vitamin D 2 and D 3 at Questions or Requests? Contact ClinicalResearch@phenomenex.com for questions on applications or to request additional applications. 13

14 25-OH-Vitamin D 3 and 3-epi-25-OH-Vitamin D 3 Vitamin D (Ergocalciferol, D 2 and Cholecalciferol, D 3 ) has been under intense investigations and its beneficial health effects have been associated with various treatments from treating bone deficiency to a potent anticancer agent. However, isomerization of monohydroxy Vitamin D produces 3-epi (conversion of a-oh to ß-OH), a diasteromeric form. There is some ambiguity as to the clinical significance of the 3-epi isomer in general population and is currently under investigation. Method Highlights Good separation of 25-OH-Vitamin D 3 and 3-epi-25-OH-Vitamin D 3 for accurate quantitation using Kinetex 2.6 µm PFP HPLC column Fast run time in less than 5 minutes LC/MS/MS Analysis Column: Kinetex 2.6 µm PFP Dimensions: 1 x 2.1 mm Part No.: D-4477-AN Mobile Phase: A:.1 % Formic acid in DI Water B:.1 % Formic acid in Methanol Gradient: Time (min) % B Flow Rate:.4 ml/min Temperature: Ambient Detection: Mass Spectrometer (MS/MS) Detector: AB SCIEX API 5 View our technical note on 3-epi-25-OH Vitamin D 3 at MRM Transitions Analyte Q1 Q3 OH-Vit D OH-Vit D3/Epi-D IS (OH-D3-2H3) OH-Vit D3 (Sec trans) OH-Vit D2 (Sec trans)

15 25-OH-Vitamin D 3 and 3-epi-25-OH-Vitamin D 3 (cont d) 2.4e6 2.2e6 2.e6 1.8e6 25-OH-D 3 1.6e6 Intensity, cps 1.4e6 1.2e6 1.e6 8.e5 6.e5 3-Epi-25-OH-D 3 25-OH-D 2 4.e5 2.e min App ID 23 OH-Vitamin D 3 Calibration Curve from ng/ml Analyte Area / IS Area Analyte Conc. / IS Conc. App ID 27 OH-Vitamin D 2 Calibration Curve from ng/ml.34 Analyte Area / IS Area Analyte Conc. / IS Conc. App ID 26 15

16 Kinetex Ordering Information 2.6 µm Analytical Columns (mm) SecurityGuard ULTRA Cartridges Phases 3 x x x x x 4.6 3/pk XB-C18 B-4496-E C-4496-E D-4496-E F-4496-E AJ-8768 C18 A-4462-E B-4462-E C-4462-E D-4462-E F-4462-E AJ-8768 C8 B-4497-E C-4497-E D-4497-E F-4497-E AJ-877 PFP A-4477-E B-4477-E C-4477-E D-4477-E F-4477-E AJ-8773 HILIC A-4461-E B-4461-E C-4461-E D-4461-E F-4461-E AJ-8772 Phenyl-Hexyl B-4495-E D-4495-E F-4495-E AJ-8774 for 4.6 mm ID NEW 5 µm Columns Available! Call for details 5 µm 2.6 µm MidBore Columns (mm) SecurityGuard ULTRA Cartridges Phases 3 x 3. 5 x x 3. 1 x x 3. 3/pk XB-C18 A-4496-Y B-4496-Y C-4496-Y D-4496-Y F-4496-Y AJ-8775 C18 A-4462-Y B-4462-Y C-4462-Y D-4462-Y F-4462-Y AJ-8775 C8 A-4497-Y B-4497-Y C-4497-Y D-4497-Y F-4497-Y AJ-8777 PFP A-4477-Y B-4477-Y C-4477-Y D-4477-Y F-4477-Y AJ-878 HILIC A-4461-Y F-4461-Y AJ-8779 Phenyl-Hexyl D-4495-Y F-4495-Y AJ-8781 for 3. mm ID 2.6 µm Minibore Columns (mm) SecurityGuard ULTRA Cartridges Phases 3 x x x x 2.1 3/pk XB-C18 A-4496-AN B-4496-AN D-4496-AN F-4496-AN AJ-8782 C18 A-4462-AN B-4462-AN D-4462-AN F-4462-AN AJ-8782 C8 A-4497-AN B-4497-AN D-4497-AN F-4497-AN AJ-8784 PFP A-4477-AN B-4477-AN D-4477-AN F-4477-AN AJ-8787 HILIC A-4461-AN B-4461-AN D-4461-AN F-4461-AN AJ-8786 Phenyl-Hexyl A-4495-AN B-4495-AN D-4495-AN F-4495-AN AJ-8788 for 2.1 mm ID 1.7 µm MidBore Columns (mm) SecurityGuard ULTRA Cartridges Phases 3 x 3. 5 x 3. 1 x 3. 3/pk XB-C18 A-4498-Y B-4498-Y D-4498-Y AJ-8775 C18 B-4475-Y D-4475-Y AJ-8775 C8 A-4499-Y B-4499-Y D-4499-Y AJ-8777 PFP D-4476-Y AJ-878 HILIC B-4474-Y AJ-8779 Phenyl-Hexyl AJ-8781 for 3. mm ID 1.7 µm Minibore Columns (mm) SecurityGuard ULTRA Cartridges Phases 3 x x x x 2.1 3/pk XB-C18 A-4498-AN B-4498-AN D-4498-AN F-4498-AN AJ-8782 C18 A-4475-AN B-4475-AN D-4475-AN F-4475-AN AJ-8782 C8 A-4499-AN B-4499-AN D-4499-AN F-4499-AN AJ-8784 PFP A-4476-AN B-4476-AN D-4476-AN F-4476-AN AJ-8787 HILIC A-4474-AN B-4474-AN D-4474-AN AJ-8786 Phenyl-Hexyl B-45-AN D-45-AN F-45-AN AJ-8788 for 2.1 mm ID SecurityGuard ULTRA cartridges require holder, Part No.: AJ-9 If Kinetex core-shell columns do not provide at least an equivalent separation as compared to a competing column of the same phase, return the column with the comparative data within 45 days for a FULL REFUND. SecurityGuard ULTRA Cartridge System The SecurityGuard ULTRA cartridge system protects ultra-high performance columns, like Kinetex, from damaging contaminants and microparticulates. Extend UHPLC column lifetime Simple to use Pressure rated to 2, psi (1,378 bar) Fits virtually all manufacturers columns SecurityGuard ULTRA Cartridge Holders Part No. Description Unit AJ-9 SecurityGuard ULTRA Cartridge Holder ea UHPLC / HPLC Sure-Lok High Pressure PEEK Male Nut Fittings Part No. Description Unit AQ-853 Sure-Lok High Pressure PEEK 1-Pc Nut 1-32, 1/pk for 1/16 in. Tubing, 12, psi (827 bar) AQ-853 Sure-Lok Fitting Tightening Tool, Aluminum ea AQ-853 AQ

17 Gemini U.S. Patent No. 7,563,367 Ordering Information 3 µm Microbore, Minibore and Narrow Bore Columns (mm) SecurityGuard Cartridges (mm) Phases 5 x 1. 2 x 2. 3 x 2. 5 x 2. 1 x x 2. 5 x 3. 1 x x 3. 4 x 2.* /1pk C18 B-4439-A M-4439-B A-4439-B B-4439-B D-4439-B F-4439-B B-4439-Y D-4439-Y F-4439-Y AJ-7596 C6-Phenyl B-4443-A A-4443-B B-4443-B D-4443-B F-4443-B B-4443-Y D-4443-Y F-4443-Y AJ-7914 /1pk NX-C18 M-4453-B A-4453-B B-4453-B D-4453-B F-4453-B B-4453-Y D-4453-Y F-4453-Y AJ-8367 for ID: mm 3 µm Analytical Columns (mm) SecurityGuard Cartridges (mm) Phases 2 x 4. 3 x x x x x x 3.* /1pk C18 M-4439-D A-4439-E B-4439-E D-4439-E F-4439-E G-4439-E AJ-7597 C6-Phenyl A-4443-E B-4443-E D-4443-E F-4443-E G-4443-E AJ-7915 /1pk NX-C18 B-4453-E D-4453-E F-4453-E G-4453-E AJ-8368 for ID: mm 5 µm Minibore and Narrow Bore Columns (mm) SecurityGuard Cartridges (mm) Phases 3 x 2. 5 x x x 2. 5 x 3. 1 x x x 3. 4 x 2.* /1pk C18 A-4435-B B-4435-B F-4435-B G-4435-B B-4435-Y D-4435-Y F-4435-Y G-4435-Y AJ-7596 C6-Phenyl A-4444-B B-4444-B F-4444-B B-4444-Y F-4444-Y G-4444-Y AJ-7914 /1pk NX-C18 A-4454-B B-4454-B F-4454-B B-4454-Y D-4454-Y F-4454-Y G-4454-Y AJ-8367 for ID: mm 5 µm Analytical Columns (mm) SecurityGuard Cartridges (mm) Phases 3 x x x x x x 3.* /1pk C18 A-4435-E B-4435-E D-4435-E F-4435-E G-4435-E AJ-7597 C6-Phenyl A-4444-E B-4444-E D-4444-E F-4444-E G-4444-E AJ-7915 /1pk NX-C18 B-4454-E D-4454-E F-4454-E G-4454-E AJ-8368 for ID: mm *SecurityGuard Analytical Cartridges require holder, Part No.: KJ-4282 If Gemini analytical columns do not provide at least an equivalent separation as compared to a competing column of the same particle size, similar phase and dimensions, return the column with comparative data within 45 days for a FULL REFUND. 17

18 Impact Rapid protein precipitation Quickly clean up sample by passing biological samples through the Impact filter Increase sensitivity of your analysis by eliminating proteins which contribute to baseline noise and decreased column lifetime Increase reproducibility with the leak-free membrane, preventing premature sample breakthrough and incomplete protein precipitation Impact Ordering Information Impact Precipitation Products Part No. Description Unit Impact Precipitation Products CE-7565 Impact Protein Precipitation, Square Well, Filter Plate, 2 ml 2/box Impact Starter Kit for Protein Precipitation CE-821 Impact Protein Precipitation Plate (2 ea) Collection Plate 2 ml (2 ea) Sealing Mat, Santoprene (AH-8199) (2 ea) ea If Impact does not perform as well or better than your current protein precipitation plate with similar specifications, return the product with comparative data within 45 days for a FULL REFUND. Product Limitations 18 The products offered in this catalog and Phenomenex Analyte Specific Reagent products are not intended for clinical use. Because they are not intended for clinical use, no claim or representation is made or intended for their clinical use (including, but not limited to diagnostic, prognostic, therapeutic or blood banking). It is the user s responsibility to validate the performance of Phenomenex products for any particular use, since the performance characteristics are not established. Phenomenex products may be used in clinical diagnostic laboratory systems after the laboratory has validated their complete system as required by the Clinical Laboratory Improvements Amendments of 1988 (CLIA 88) regulation in the U.S. or equivalent in other countries.

19 Phree Phree is a high-throughput solution for simultaneous removal of protein and all classes of phospholipids to maximize sensitivity and column lifetime. Phospholipid Removal Solutions Remove Proteins Solvent Shielding Technology prevents dripping of organic solvent, allowing for protein precipitation within the wells of the Phree Phospholipid Removal Product. Eliminate Phospholipids The Phree sorbent selectively removes phospholipids from precipitated plasma samples. No Method Development One method for acids, bases, and neutrals Proteins Phospholipids Target Analyte Phree Ordering Information Part No. Description Unit 8E-S133-TGB Phree Phospholipid Removal 96-Well Plates 2/box Collection Plates (deep well, polypropylene) AH-7192 Strata 96-Well Collection Plate 35 µl/well 5/pk AH-7193 Strata 96-Well Collection Plate 1 ml/well 5/pk AH-7194 Strata 96-Well Collection Plate 2 ml/well 5/pk AH-8635 Strata 96-Well Collection Plate, 2 ml Square/Round-Conical 5/pk AH-8636 Strata 96-Well Collection Plate, 2 ml Round/Round, 8 mm 5/pk AH-7279 Strata 96-Well Collection Plate, 1 ml/well Round, 7 mm 5/pk Sealing Mats AH-8597 Sealing Mats, Pierceable, 96-Square Well, Silicone 5/pk AH-8598 Sealing Mats, Pre-Slit, 96-Square Well, Silicone 5/pk AH-8631 Sealing Mats, Pierceable, 96-Round Well 7 mm, Silicone 5/pk AH-8632 Sealing Mats, Pre-Slit, 96-Round Well 7 mm, Silicone 5/pk AH-8633 Sealing Mats, Pierceable, 96-Round Well 8 mm, Silicone 5/pk AH-8634 Sealing Mats, Pre-Slit, 96-Round Well 8 mm, Silicone 5/pk AH-7362 Sealing Tape Pad 1/pk Vacuum Manifold AH-895 Strata 96-Well Plate Manifold, Universal with Vacuum Gauge ea If Phree Phospholipid Removal products do not perform as well or better than your current phospholipid removal products, return the product with comparative data within 45 days for a FULL REFUND. 19

20 ) ) ) Solid Phase Extraction for Optimal Cleanup Strata-X U.S. Patent No. 7,119,145 A reversed phase functionalized polymeric sorbent that gives strong retention of neutral, acidic, or basic compounds under aggressive, high organic wash conditions. Material Characteristics Particle Size (µm) 33 Pore Size (Å) 85 Surface Area (m 2 /g) 8 ph Stability Mechanisms of Retention π-π Bonding Hydrogen Bonding Dipole-Dipole Interactions Hydrophobic Interaction )n O )n O )n O Ṅ. Ṅ. Ṅ. Strata-X Ordering Information Sorbent Format Mass Part Number Unit Tube 3 mg 8B-S1-TAK 1 ml (1/box) 3 mg 8B-S1-TBJ 3 ml (5/box) 6 mg 8B-S1-UBJ 3 ml (5/box) 1 mg 8B-S1-EBJ 3 ml (5/box) 1 mg 8B-S1-ECH 6 ml (3/box) 2 mg 8B-S1-FBJ 3 ml (5/box) 2 mg 8B-S1-FCH 6 ml (3/box) 5 mg 8B-S1-HBJ 3 ml (5/box) 5 mg 8B-S1-HCH 6 ml (3/box) Giga Tube 5 mg 8B-S1-HDG 12 ml (2/box) 1 g 8B-S1-JDG 12 ml (2/box) 1 g 8B-S1-JEG 2 ml (2/box) 2 g 8B-S1-KEG 2 ml (2/box) 5 g 8B-S1-LFF 6 ml (16/box) Teflon Tube 2 mg 8B-S1-FBJ-T 3 ml (5/box) 2 mg 8B-S1-FDG-T 12 ml (2/box) 96-Well Plate 1 mg 8E-S1-AGB 2 Plates/Box 3 mg 8E-S1-TGB 2 Plates/Box 6 mg 8E-S1-UGB 2 Plates/Box General Extraction Protocol Method written for a 3 mg/1 ml tube 1. Condition 1 ml Methanol followed by 1 ml DI Water 2. Load: Pretreated sample 3. Wash: 1 ml 5-6 % Methanol in DI Water 4. Dry: Sorbent for 3 seconds 5. Elute: 2x 5 µl 2 % Formic acid in Methanol or Acetonitrile On-line Extraction Cartridge Description Part Number Unit/Box Strata-X on-line extraction M-S33-B-CB ea cartridge, 2 x 2. mm Cartridge holder, 2 mm CH-5845 ea If Strata-X SPE products do not perform as well or better than your current SPE product of similar phase, mass and size, return the product with comparative data within 45 days for a FULL REFUND. Instant Method Development Create your Own SPE Method in under 1 minute! 2

21 An Analytical Support Laboratory PhenoLogix customizes solutions to fit your exact needs and requirements so methods can be transferred efficiently and effectively back into your lab upon completion. Please contact us to get started on your method. or Visit: How can we be of service? PhenoLogix worldwide technical teams are here to provide full service method support and training for you and your lab. Our services include: Method Improvement and Optimization New Method Development Validation and Pre-validation Services On-Site Training and Consulting Partial list of resources used in the PhenoLogix lab Agilent, Shimadzu, ACQUITY and JASCO HPLC and UHPLC systems API 3 LC/MS/MS API 4 LC/MS/MS API 5 LC/MS/MS 4 Q-TRAP LC/MS/MS Waters Micromass Quattro MS Agilent and Shimadzu GC/MS systems Gilson and PerkinElmer liquid handlers

22 Australia t: f: Austria t: f: Belgium t: (French) t: (Dutch) f: +31 () beinfo@phenomenex.com Canada t: (8) f: (31) info@phenomenex.com Denmark t: f: nordicinfo@phenomenex.com Finland t: f: nordicinfo@phenomenex.com France t: f: franceinfo@phenomenex.com Germany t: f: anfrage@phenomenex.com India t: f: indiainfo@phenomenex.com Ireland t: f: eireinfo@phenomenex.com Italy t: f: italiainfo@phenomenex.com Luxembourg t: +31 () f: +31 () nlinfo@phenomenex.com Mexico t: f: tecnicomx@phenomenex.com The Netherlands t: f: nlinfo@phenomenex.com New Zealand t: f: nzinfo@phenomenex.com Norway t: f: nordicinfo@phenomenex.com Puerto Rico t: (8) 541-HPLC f: (31) info@phenomenex.com Sweden t: f: nordicinfo@phenomenex.com United Kingdom t: f: ukinfo@phenomenex.com United States t: (31) f: (31) info@phenomenex.com All other countries: Corporate Office USA t: (31) f: (31) info@phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com BR _W Terms and Conditions Subject to Phenomenex Standard Terms & Conditions, which may be viewed at Trademarks Phenomenex, Luna, Gemini, Kinetex, and Strata are registered trademarks, and MidBore, Phree, Solvent Shielding Technology, ph-lc, Impact, Giga, SecurityGuard, Strata-X, Sure-Lok, Synergi, and TWIN are trademarks of Phenomenex. Micromass, Waters, and ACQUITY are registered trademarks, and Quattro is a trademark of Waters Corporation. JASCO is a registered trademark of JASCO, Inc. Agilent is a registered trademark of Agilent Technologies, Inc. API 3, API 4, and API 5 are trademarks and QTRAP is a registered trademark of AB SCIEX Pte. Ltd. Gilson is a registered trademark of Gilson, Inc. PerkinElmer is a registered trademark of PerkinElmer Inc. SGE is a registered trademark and FocusLiner is a trademark of SGE. Teflon is a registered trademark of E.I. du Pont de Nemours. Shimadzu is a registered trademark of Shimadzu Corporation. Disclaimer Phenomenex is not affiliated with Agilent Technologies, JASCO, Gilson, PerkinElmer, or Waters Corporation. Comparative separations may not be representative of all applications. Gemini-NX is patented by Phenomenex. U.S. Patent No. 7,563,367 SecurityGuard is patented by Phenomenex. U.S. Patent No. 6,162,362 CAUTION: this patent only applies to the analytical-sized guard cartridge holder, and does not apply to SemiPrep, PREP or ULTRA holders, or to any cartridges. Strata-X is patented by Phenomenex. U.S. Patent No. 7,119, Phenomenex, Inc. All rights reserved.

Labs Across the World Are Advancing Their Protein Precipitation

Labs Across the World Are Advancing Their Protein Precipitation Phospholipid Removal Solutions Labs Across the World Are Advancing Their Protein Precipitation Achieve Cleaner Samples Extend HPLC Column Lifetime Improve Analyte Sensitivity Reduce Mass Spec Maintenance

More information

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns Shuguang Li, Sky Countryman, and Erica Pike Phenomenex,

More information

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1. APPLICATIONS A Simple and Effective High ph LC/MS/MS Method for Determination of Underivatized Vitamin B1 and B6 in Human Whole Blood Ramkumar Dhandapani Technical Manager Ramkumar loves to write poems,

More information

Keep it Clean with Strata -X

Keep it Clean with Strata -X Simplified Solid Phase Extraction Solutions Neutral Compounds Acidic Compounds Basic Compounds Strong Acids (pk a < 2 Weak Acids (pk a 2-4 Neutral Compounds Weak Bases (pk a 8-10 Strong Bases (pk a > 10

More information

APPLICATIONS TN Materials and Methods

APPLICATIONS TN Materials and Methods APPLICATIONS A Simple, Fast, and Efficient HPLC Method for Sensitive, Accurate, and Reproducible Quantitation of Vitamin C in Human Plasma by Applying Impact Protein Precipitation Plate Technology with

More information

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W Simple, Fast and Accurate Quantitation of Human Plasma Vitamins and Their Metabolites by Protein Precipitation Combined with Columns Using HPLC-UV, HPLC-FLD or LC/MS/MS Shuguang Li, Jason Anspach, Sky

More information

PAIN PANEL. Research and Solutions

PAIN PANEL. Research and Solutions PAIN PANEL Research and Solutions Pain management drug use and abuse has increased significantly in recent years. The 21 National Survey on Drug Use & Health (NSDUH) reports that 17.3% of first-time drug

More information

Phospholipid Removal Solutions

Phospholipid Removal Solutions Remove Phospholipids Remove Protein No Method Development www.phenomenex.com/phree One Quick Method, Three Big Advantages 1 2 Remove Proteins that can clog HPLC columns Eliminate Phospholipids that cause

More information

Protect Your Mass Spec

Protect Your Mass Spec Protect Your Mass Spec Sample Preparation Solutions for Biological Samples www.phenomenex.com/bioms Dirty Samples Could be Costing You Money and Sensitivity Biological samples contain a wide variety of

More information

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex.6 µm Core-Shell Technology Column Philip J. Koerner, Matthew Trass, and Jeff Layne Phenomenex, Inc., Madrid Ave.,

More information

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse Keep It Clean Solid Phase Extraction Solutions for Drugs of Abuse Analysis Neutral Drugs of Abuse Basic Drugs of Abuse Strata -X-Drug B: Basic Drugs of Abuse Working with basic drugs? Here are 3 reasons

More information

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE)

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE) APPLICATIONS A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE) Ann Montross Technical Specialist Ann enjoys cooking/baking and roasting her

More information

Finally, a Solid Phase Extraction product for Drugs of Abuse

Finally, a Solid Phase Extraction product for Drugs of Abuse n io t c a r t x E e s a h P d li Finally, a So e s u b A f o s g u r D r fo product Imagine Only Needing 1 SPE Sorbent For All of Your Drugs of Abuse Extractions Extract over 11 drugs using the same sorbent

More information

APPLICATIONS TN Analytical Method

APPLICATIONS TN Analytical Method APPLICATIONS Simultaneous Determination of Antidepressants and Metabolites in Urine Using Ultra-High Performance Liquid Chromatography Tandem Mass Spectrometry (UHPLC-MS/MS) using a Kinetex Core-Shell

More information

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite T-1154 APPLICATIS Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS Matthew Trass, Shahana Huq, Seyed Sadjadi, Sky Countryman and Zdravko

More information

PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes

PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes Application Guide PAIN PANEL Screen 41 compounds in under 4 minutes Solutions for large compound screens and individual compound classes such as benzodiazepines, opiates, and more Achieve resolution of

More information

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns. For Far Greater UHPLC Column Performance... You Must Have Kinetex Core-Shell UHPLC Columns www.phenomenex.com/kinetex The UHPLC Core-Shell Advantage Kinetex Core-Shell Technology produces increased efficiencies

More information

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology. Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology Jeff Layne, Phenomenex, Inc. Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 951 USA With virtually

More information

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD Determination of Sugars in Animal Feed using HPLC-ELSD Laura Snow, Zeshan Aqeel, Allen Misa and Scott Krepich Phenomenex, Inc., Madrid Ave., Torrance, CA 9050 USA Laura Snow Scientist- Phenologix Outside

More information

Core-Shell Technology for Proteins and Peptides

Core-Shell Technology for Proteins and Peptides Core-Shell Technology for Proteins and Peptides Better BioSeparations on HPLC and UHPLC Systems www.phenomenex.com/aeris Aeris Core-Shell Technology Core-Shell Particles Precision Engineered for Protein

More information

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1 APPLICATIONS A Comparison of Various Kinetex C18 Phases Zeshan Aqeel and Jeff Layne Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA Introduction When performing reversed phase LC separations, there

More information

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market Better UHPLC Performance Starts NW.7 µm Core-Shell * Columns The IRST and NLY sub- µm core-shell columns on the market Phenomenex India Laxmi Cyber City, Ground loor, B Block, Survey no: Kondapur, Hyderabad

More information

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Michael McGinley, Deborah Jarrett, and Jeff Layne Phenomenex, Inc., 411 Madrid Avenue, Torrance, CA 91 USA Aeris WIDEPORE

More information

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology Determination of Impurities and Related Substances for Acetylsalicylic Acid (Ph. Eur. Monograph 9): Increased Sensitivity and Resolution, Faster Analysis, and Reduced Solvent Usage Using Kinetex 2.6 µm

More information

Preparative Chromatography Meets UHPLC

Preparative Chromatography Meets UHPLC Preparative Chromatography Meets UHPLC The Power of Kinetex Core-Shell Technology with the Performance of Piston Packed Prep Columns Ultra-High Efficiencies Ultra-Long Lifetimes NO Added Pressure Two Award

More information

Strata -X Polymeric SPE

Strata -X Polymeric SPE Strata - Polymeric SPE Strata- Benefits of Strata- SPE vs. Traditional SPE Increase Detection Sensitivity by removing matrix contaminants Increase Column Lifetime by removing matrix contaminants Quality

More information

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you!

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you! Core-Shell Technology NEW Kinetex enyl Biph Biphenyl TM S TM Selectivity that a C8 just can t give you! S Bip he ylhenyl Bnip Remarkable Separation Power Rugged and Reliable % Aqueous Stable Kinetex Core-Shell

More information

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit Kinetex 5 µm Core-Shell Columns Deliver Significant Improvements in Chromatographic Efficiency and Resolution versus Traditional Fully Porous 5 µm Columns Philip J. Koerner and Jeff Layne Phenomenex, Inc.,

More information

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs. Table 1. List of pain panel drugs

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs. Table 1. List of pain panel drugs APPLICATION Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs Seyed Sadjadi, Shahana Huq, Sean Orlowicz, and Laura Snow Phenomenex, 4 Madrid Avenue, Torrance,

More information

Strata-X- NEW! Drug B. Drug B Plus for In-Well Hydrolysis. Simplify Your Solid Phase Extraction.

Strata-X- NEW! Drug B. Drug B Plus for In-Well Hydrolysis. Simplify Your Solid Phase Extraction. Polymeric SPE Strata-X- Drug B Simplify Your Solid Phase Extraction QC Tested for Drugs of Abuse No Equilibration or Conditioning Required NEW! Drug B Plus for In-Well Hydrolysis www.phenomenex.com/strataxdrug

More information

METHAMPHETAMINE & AMPHETAMINE

METHAMPHETAMINE & AMPHETAMINE METHAMPHETAMINE & AMPHETAMINE Enantiomers from Urine Rapid and Accurate Chiral Separation Polysaccharide Chiral Chiral LC LC Columns and SFC PHEN-RUO-49 Revision: Lux 3 µm AMP Column High Efficiency LC/MS/MS

More information

Supported Liquid Extraction (SLE) For Food Applications

Supported Liquid Extraction (SLE) For Food Applications Supported Liquid Extraction (SLE) For Food Applications Novum Synthetic SLE Unique, Synthetic Sorbent that Provides Consistent, Reliable Results Strata DE Diatomaceous Earth SLE Cost-Effective, Guaranteed

More information

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases T-1164 APPLICATIS Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases Marc Jacob, Liming Peng, Michael Klein, Tom eveland,

More information

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced SIMPLIFIED IRAL SEPARATIS Lux ellulose- Guaranteed Alternative to IRALEL D- Exceptional Quality Sensibly Priced Lux ellulose- ellulose tris(3,5-dimethylphenylcarbamate) This dimethyl cellulose selector

More information

CANNABIS TESTING ACCESSORIES

CANNABIS TESTING ACCESSORIES CANNABIS TESTING ACCESSORIES HPLC/GC/Sample Prep www.phenomenex.com/cannabis Popular Accessories for Cannabis Testing Cannabis Testing Accessories Sample Preparation Vials Sample Preparation Phenex Syringe

More information

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns Core-Shell Technology 11 HPLC Myths Uncovered & Why You Must Have Kinetex Core-Shell HPLC Columns 2.6 www.phenomenex.com/kinetex HPLC myths have been around since the early 19 s! From the one about the

More information

Yes You Can! New! Amazing EVO C18. Core-Shell Technology

Yes You Can! New! Amazing EVO C18. Core-Shell Technology Core-Shell Technology Yes You Can! New! Amazing EVO C8 Develop robust methods from ph - Get improved peak shape for bases Easily reduce run times and increase sensitivity THE PAST Fully Porous You used

More information

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE Aeris Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations Aeris is a specialized line of reversed phase core-shell UHPLC columns, built exclusively for the ultra-high performance

More information

Figure 1. Core-Shell Particle Technology

Figure 1. Core-Shell Particle Technology Purification of Chlorogenic cid from Green Coffee using Kinetex Core-Shell Technology in xia Preparative Formats Zeshan qeel Technical Magician Zeeshan loves to collect watches and the ack to the Future

More information

CLINICAL RESEARCH APPLICATIONS GUIDE

CLINICAL RESEARCH APPLICATIONS GUIDE CLINICAL RESEARCH APPLICATINS GUIDE More throughput Greater sensitivity Reduced costs Less downtime Your job has never demanded more from you. Doctors need accurate results yesterday. You need to minimize

More information

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS) High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS) Michael Rummel, Matthew Trass, Michael Campognone, and Sky Countryman Phenomenex, Inc., 411 Madrid Avenue, Torrance,

More information

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS By Shun-Hsin Liang and Frances Carroll Abstract Vitamin K₁ and K₂ analysis is typically complex and time-consuming because these

More information

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS Introduction Drug analysis from whole blood is gaining popularity due to a more complete measurement

More information

APPLICATION TN Materials and Methods Reagents and Chemicals

APPLICATION TN Materials and Methods Reagents and Chemicals TN-8 APPLICATION Fast Analysis of Sucrose,, and Composition in Fruit Juices and Processed Beverages using Simplified HPLC Methodology Brian Rivera Product Manager In addition to chromatography, Brian also

More information

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput ULTIMATE HPLC/UHPLC CMB Kinetex Luna mega Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput NEW MEGA Core-Shell Technology Luna mega Luna mega PS Kinetex. Kinetex Luna mega Cutting

More information

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA

More information

APPLICATIONS TN Rapid, High Resolution Analysis of Aflatoxin Extracts from Peanut Butter Using Kinetex Core-Shell Technology and Strata SPE

APPLICATIONS TN Rapid, High Resolution Analysis of Aflatoxin Extracts from Peanut Butter Using Kinetex Core-Shell Technology and Strata SPE APPLICATINS Rapid, High Resolution Analysis of Aflatoxin Extracts from Peanut Butter Using Kinetex Core-Shell Technology and Strata SPE Sky Countryman, Shahana Huq, Terrell Mathews, et al. Phenomenex,

More information

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB:

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB: Exceed your Purification Goals Guaranteed The Axia Prep Column Advantage Extended column lifetime Reproducibility: column-to-column and batch-to-batch igher efficiency Improved peak shape Increased loadability

More information

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology Core-Shell Technology Kinetex EVO C8 HPLC/UHPLC Core-Shell Columns Greater Polar Retention with % Aqueous Stability Robust Methods from ph - Improved Peak Shape for Bases NEW.7 µm NEW. µm µm Unconventionally

More information

CLINICAL RESEARCH APPLICATIONS GUIDE

CLINICAL RESEARCH APPLICATIONS GUIDE CLINICAL RESEARC APPLICATINS GUIDE Your job has never demanded more from you. Doctors need accurate results yesterday. You need to minimize costs while increasing the number of samples run. New tests require

More information

Dienes Derivatization MaxSpec Kit

Dienes Derivatization MaxSpec Kit Dienes Derivatization MaxSpec Kit Item No. 601510 www.caymanchem.com Customer Service 800.364.9897 Technical Support 888.526.5351 1180 E. Ellsworth Rd Ann Arbor, MI USA TABLE OF CONTENTS GENERAL INFORMATION

More information

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis Application Note AN784 Extraction of Multiple Mycotoxins from Nuts Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis This application note

More information

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis Application Note AN807 Extraction of Aflatoxin M From Infant Formula Using ISLUTE Myco Page Extraction of Aflatoxin M From Infant Formula Using ISLUTE Myco SPE Columns prior to LC-MS/MS Analysis This application

More information

An Easier QuEChERS Solution for Diverse Matrices. Learn more at

An Easier QuEChERS Solution for Diverse Matrices. Learn more at An Easier QuEChERS Solution for Diverse Matrices Learn more at www.phenomenex.com/roq What is roq QuEChERS? QuEChERS is a descriptive acronym that stands for Quick, Easy, Cheap, Effective, Rugged, and

More information

NEW Kinetex F5. HPLC/UHPLC Core-Shell Columns

NEW Kinetex F5. HPLC/UHPLC Core-Shell Columns Core-Shell Technology NEW Kinetex Whoa! I can even separate structural isomers! TMS TMS HPLC/UHPLC Core-Shell Columns Reduce Method Development Time by Days Greater Reproducibility than other PPs Glorious

More information

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Evelyn Goh Waters Pacific, Singapore APPLICATION BENEFITS This method allows for the simultaneous analysis of 12 water-soluble

More information

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis Application Note AN782 Extraction of Multiple Mycotoxins from Grain Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis This application

More information

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis Providing a Universal, ne-step Alternative to Liquid-Liquid Extraction in Bioanalysis Jessalynn P. Wheaton, Erin E. Chambers, and Kenneth J. Fountain APPLICATIN BENEFITS n Simple, one-step sample preparation

More information

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates Application Note Clinical Research Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates Authors Limian Zhao and Megan Juck Agilent Technologies, Inc. Abstract

More information

There's a Cleaner Way!

There's a Cleaner Way! Using Liquid-Liquid Extraction (LLE)? There's a Cleaner Way! LLE Liquid-Liquid Extraction START SPE Solid Phase Extraction SLE Supported Liquid Extraction STOP STOP Cleanest Cleaner www.phenomenex.com/replacelle

More information

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry Application Note Food Safety Authors Chenhao Zhai Agilent

More information

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis The Investigation of Factors Contributing to Immunosuppressant Drugs Variability in LC-MS/MS Analysis Joseph Herman, Dayana Argoti, and Sarah Fair Thermo Fisher Scientific, Franklin, MA, USA Overview Purpose:

More information

APPLICATION TN Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns

APPLICATION TN Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns APPLICATION Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns Sean Orlowicz Manager, PhenoLogix When not in the lab, Sean

More information

Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE. PLD+ Prior to LC-MS/MS Analysis

Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE. PLD+ Prior to LC-MS/MS Analysis Application Note AN842.V. Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE PLD+ Prior to LC-MS/MS Analysis Page Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE PLD+ Prior to LC-MS/MS

More information

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No. Page 1 of 10 Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection EPL-BAS Method No. 205G881B Method Summary: Residues of 6-CPA are

More information

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation PO-CON69E Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation MSACL 6 EU Stéphane Moreau, Daisuke Kawakami, Toshikazu Minohata Shimadzu Europe GmbH, Duisburg,

More information

Comprehensive Study of SLE as a Sample. Preparation Tool for Bioanalysis

Comprehensive Study of SLE as a Sample. Preparation Tool for Bioanalysis Comprehensive Study of SLE as a Sample Preparation Tool for Bioanalysis Wan Wang, Warren Chen, Jerry Wang Bonna-Agela Technologies 179 Southern Street, West TEDA, Tianjin, China Abstract A simple, fast,

More information

Polymeric Sorbents for Sample Preparation

Polymeric Sorbents for Sample Preparation Polymeric Sorbents for Sample Preparation Better Reproducibility Cleaner Extracts Faster Method Development Discover the benefits of strata -X It s Absolute Magic! We re now using half the reagents, half

More information

TN-0116 Scott Krepich

TN-0116 Scott Krepich TN-116 APPLICATIONS Analysis of Perfluorinated Compounds (PFCs) in Aqueous Matrices, Evaluating Various Online SPE Sorbents by LC-MS/MS Scott Krepich Senior Field Application Scientist Scott enjoys surfing

More information

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system Xiang He 1, Adrian Taylor 2 and Alexandre Wang 1 1 SCIEX, Redwood City, USA. 2 SCIEX, Concord,

More information

Determination of Patulin in Apple Juice Using SPE and UHPLC-MS/MS Analysis

Determination of Patulin in Apple Juice Using SPE and UHPLC-MS/MS Analysis Determination of Patulin in Apple Juice Using SPE and UHPLC-MS/MS Analysis UCT Part Numbers ECHLD126-P ENVIRO-CLEAN HLDVB mg/6ml SPE cartridge PE Frit SLDAID21-18UM Selectra DA UHPLC column ( 2.1 mm, 1.8

More information

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column Clinical, Forensic & Toxicology Applications 4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column By Amanda Rigdon Abstract A rapid, sensitive method

More information

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs Seyed Sadjadi, Shahana Huq, Sean Orlowicz and Laura Snow Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis

More information

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography Application ote Food Safety Authors Chen-Hao Zhai and Yun Zou Agilent Technologies Co. Ltd.

More information

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid Application Note Clinical Research Authors Derick Lucas and Limian Zhao Agilent Technologies, Inc. Abstract Lipids from

More information

Application Note. Author. Abstract. Introduction. Food Safety

Application Note. Author. Abstract. Introduction. Food Safety Determination of β2-agonists in Pork with SPE eanup and LC-MS/MS Detection Using Agilent BondElut PCX Solid-Phase Extraction Cartridges, Agilent Poroshell 120 column and Liquid Chromatography-Tandem Mass

More information

Core E Analysis of Neutral Lipids from Human Plasma June 4, 2010 Thomas J. Leiker and Robert M. Barkley

Core E Analysis of Neutral Lipids from Human Plasma June 4, 2010 Thomas J. Leiker and Robert M. Barkley Core E Analysis of Neutral Lipids from Human Plasma June 4, 2010 Thomas J. Leiker and Robert M. Barkley This protocol describes the extraction and direct measurement of cholesterol esters (CEs) and triacylglycerols

More information

SecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed!

SecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed! U.S. Patent No. 6, 162, 362 Column Protection for UHPLC, HPLC to PREP Protect HPLC columns and extend lifetime Virtually no change in chromatography Available in analytical, semi-prep, and preparative

More information

Detection of Low Level of Chloramphenicol in Milk and Honey with MIP SPE and LC-MS-MS

Detection of Low Level of Chloramphenicol in Milk and Honey with MIP SPE and LC-MS-MS Detection of Low Level of Chloramphenicol in Milk and Honey with MIP SPE and LC-MS-MS Olga Shimelis, An Trinh, and Michael Ye Supelco, Div. of Sigma-Aldrich, Bellefonte, PA T407125 Introduction Molecularly

More information

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer A Robustness Study for the Agilent 7 LC-MS/MS Mass Spectrometer Application Note Clinical Research Authors Linda Côté, Siji Joseph, Sreelakshmy Menon, and Kevin McCann Agilent Technologies, Inc. Abstract

More information

LC-MS/MS Method for the Determination of Tenofovir from Plasma

LC-MS/MS Method for the Determination of Tenofovir from Plasma LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract

More information

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring and in Urine Xiaolei Xie, Joe DiBussolo, Marta Kozak; Thermo Fisher Scientific, San Jose, CA Application Note 627 Key Words, norbuprenorphine,

More information

Enrichment of Phospholipids from Biological Matrices with Zirconium Oxide-Modified Silica Sorbents

Enrichment of Phospholipids from Biological Matrices with Zirconium Oxide-Modified Silica Sorbents Enrichment of Phospholipids from Biological Matrices with Zirconium Oxide-Modified Silica Sorbents Xiaoning Lu, Jennifer E. Claus, and David S. Bell Supelco, Div. of Sigma-Aldrich Bellefonte, PA 16823

More information

[ APPLICATION NOTE ] Oasis PRiME HLB Cartridge for Cleanup of Infant Formula Extracts Prior to UPLC-MS/MS Multiresidue Veterinary Drugs Analysis

[ APPLICATION NOTE ] Oasis PRiME HLB Cartridge for Cleanup of Infant Formula Extracts Prior to UPLC-MS/MS Multiresidue Veterinary Drugs Analysis Prior to UPLC-MS/MS Multiresidue Veterinary Drugs Analysis Michael S Young and Kim Van Tran Waters Corporation, Milford, MA, USA APPLICATION BENEFITS Efficient, timesaving multiclass/ multiresidue methodology

More information

Overcoming the Challenges of Sample Preparation and LC/MS/MS Method Development for Clinical Applications

Overcoming the Challenges of Sample Preparation and LC/MS/MS Method Development for Clinical Applications Overcoming the Challenges of Sample Preparation and LC/MS/MS Method Development for Clinical Applications Speaker: Sky Countryman, Manager of PhenoLogix and Applied Technologies, Phenomenex Webinar Host:

More information

Filtration Approaches to Sample Preparation and Cleanup. Golnar Javadi Application Engineer Sample Preparation Products

Filtration Approaches to Sample Preparation and Cleanup. Golnar Javadi Application Engineer Sample Preparation Products Filtration Approaches to Sample Preparation and Cleanup Golnar Javadi Application Engineer Sample Preparation Products Spp-support@agilent.com 1 Today s Agenda How does filtration work a brief overview

More information

Performance of an ultra low elution volume 96-well plate

Performance of an ultra low elution volume 96-well plate Performance of an ultra low elution volume 96-well plate Claude R. Mallet, Ziling Lu, Jeff R. Mazzeo, Uwe D. Neue Waters Corporation PittCon 2003 March 10-14 2003 Orlando, Florida Today s Challenges Faced

More information

Analyze Barbiturates in Urine with Agilent 6430 LC/MS/MS and Poroshell 120 EC-C18

Analyze Barbiturates in Urine with Agilent 6430 LC/MS/MS and Poroshell 120 EC-C18 Analyze Barbiturates in Urine with Agilent 6 LC/MS/MS and Poroshell EC-C8 Application ote Forensic Toxicology Authors Elijah Steinbauer and Pat Friel Toxicology Laboratory at the Veterans Administration

More information

Author. Introduction. Abstract

Author. Introduction. Abstract Simultaneous Measurement of Sirolimus and Tacrolimus Concentrations in Blood by Semi-Automated Extraction and Liquid Chromatography-Electrospray Ionization Mass Spectrometry Application Author Gary L.

More information

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS SCIEX QTRAP 4500 LC-MS/MS System and Spark Holland PICO Adrian M. Taylor 1, Peter Ringeling 2, Martin Sibum 2, Stefan Sturm

More information

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases Clinical, Forensic & Toxicology Applications Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases By Shun-Hsin

More information

Validation of an Automated Method to Remove

Validation of an Automated Method to Remove Shahana Wahab Huq 1, Richard Thomas 2, Agnes Cua 2, Seyed Sadjadi 1 1 Phenomenex, 411 Madrid Avenue, Torrance, CA 951 2 Precision Toxicology, 33 Bunker Hill Street, San Diego, CA 9219 Validation of an

More information

Fast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS

Fast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS Fast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS Christophe Deckers, M.Sc. Sample prep Application Scientist Types of ``Interferences``

More information

Analytes. Sample Preparation Procedure. Introduction. Format: Sample Pre-treatment. Sample Loading. Analyte Extraction and Derivatization.

Analytes. Sample Preparation Procedure. Introduction. Format: Sample Pre-treatment. Sample Loading. Analyte Extraction and Derivatization. Application Note AN857 Ultra-Sensitive Method for the Determination of 1,25 di-oh Vitamin D2 and 1,25 di-oh Vitamin D3 Page 1 Ultra-Sensitive Method for the Determination of 1,25 di-oh Vitamin D2 and 1,25

More information

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages APPLICATION NOTE 21671 Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages Authors Jon Bardsley, Thermo Fisher Scientific, Runcorn, UK Keywords Vanquish Flex, Acclaim PolarAdvantage

More information

LC-Based Lipidomics Analysis on QTRAP Instruments

LC-Based Lipidomics Analysis on QTRAP Instruments LC-Based Lipidomics Analysis on QTRAP Instruments Junhua Wang and Paul RS Baker SCIEX LC-Based Lipidomics Analysis Topics Covered Lipid extraction techniques Hydrophilic Interaction Chromatography (HILIC)

More information

[ CARE AND USE MANUAL ] GlycoWorks Single Use Sample Preparation Kit CONTENTS

[ CARE AND USE MANUAL ] GlycoWorks Single Use Sample Preparation Kit CONTENTS GlycoWorks Single Use Sample Preparation Kit CONTENTS I. INTRODUCTION General Guideline of Sample Preparation from Glycoprotein to enrich FLR Labeled Glycans Using Reductive Amination Reaction. II. STORAGE

More information

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS A RAPID AD SESITIVE AALYSIS METD OF SUDA RED I, II, III & IV I TOMATO SAUCE USIG ULTRA PERFORMACE LC MS/MS Choon Keow G, aomi TAAKA, Michelle KIM, Swee Lee YAP Waters Asia, Regional Technology Center,

More information

Comparison of Biotage Extrahera vs. Manual Sample Processing Using a Vacuum Manifold

Comparison of Biotage Extrahera vs. Manual Sample Processing Using a Vacuum Manifold Technical Note PPS366 Extraction of 25-OH Vitamin D from Plasma Using ISOLUTE SLE+ Page 1 Comparison of Biotage vs. Sample Processing Using a Vacuum Manifold Extraction of 25-OH Vitamin D from Plasma Using

More information