SMAC CABLE CATALOGUE. SMAC, the innovative elastomer expert FIT/10/05B
|
|
- Erik Tyler
- 6 years ago
- Views:
Transcription
1 SMAC CABLE CATALOGUE SMAC, the innovative elastomer expert FIT/10/05B
2 SMAC CABLE The SMAC CABLE wire rope isolators are entirely metallic and possess multi-axis characteristics. They are well adapted for the isolation of materials exposed to shock and vibration in harsh environment (ex: embedded electronic enclosures). The assembly of plates is ensured by stainless steel staples for 2513s to 2516s series, by stainless steel or bichromated coated with zinc steel screw for 2518s to 2526s series. The plates can be delivered with Clearence, Countersink, or Threaded fixation holes. All products can be customized to your exact requirements upon request. La gamme d amortisseurs SMAC CABLE est entièrement métallique et possède des caractéristiques multiaxiales. Ces amortisseurs sont particulièrement bien adaptés pour l isolation des matériels exposés à des chocs et des vibrations dans des environnements sévères (ex. baies électroniques embarquées). L assemblage des barrettes est assuré par des agrafes en acier inoxydable pour la série 2513S à 2516S, par des vis en acier inoxydable ou acier zingué bichromaté pour les séries 2518S à 2526S. Les barrettes peuvent être livrées avec des trous de fixation lisses, fraisés ou taraudés. Réalisations hors standard sur demande (matériaux, nombre de boucles, fixations etc.).
3 2513S to 2516S a v b h c d A L LF F M Sez. A-A e e f e A Part number a b c d e f Mass 2513S dia. 5 M4 30g to 50g 2514S dia. 6 M5 70g to 100g 2515S dia. 6 M5 130g to 160g 2516S dia. 6 M5 130g to 160g Dimensions in millimeters Descriptions Bars: Aluminum alloy Clips: Stainless steel Threaded insert: Stainless steel Standard treatment: SurTec 650 Number of loops: (W) 10 (standard) Fixing holes: No. 4 Tolerances: Hole ± 0.3 mm Center distances ± 0.5 mm h ± 2 mm v ± 2 mm Characteristics Transmissibilty: Factor at the resonance ~3 Damping: Damping factor 0.10 to 0.20 Work frequencies: Depend of weight and input level Work configuration: Every orthogonal direction Operating temperature: -180 C to +300 C
4 Technical Features P/Number h v W F 45 Cable Bar fixing 2513S dan mm dan mm L2: 4 Clearence hole dia S dan FL: 2 Countersink hole dia. 5 mm Clearence hole dia. 5 dan Stainless F2: 4 Countersink hole dia. 5 mm steel 2513S dan dia. ML: 2 threaded insert M4 1.5 mm 2 Clearence hole dia. 5 mm dan M2: 4 Threaded insert M4 mm dan FM: 2 Countersink hole dia. 5 2 threaded insert M4 mm S The value indicated corresponds dan to two 3.8 points of compression: one point minimum of 2 mm and, approx. one point maximum mm 27.0 of utile 10.0 compression S S S S dan mm dan mm dan mm dan mm dan mm dan mm dan mm dan mm Stainless steel dia. 2.4 mm L2: 4 Clearence hole dia. 6 FL: 2 Countersink hole dia. 6 2 Clearence hole dia. 6 F2: 4 Countersink hole dia. 6 ML: 2 threaded insert M5 2 Clearence hole dia. 6 M2: 4 Threaded insert M5 FM: 2 Countersink hole dia. 6 2 threaded insert M5
5 Technical Features P/Number h v W F 45 Cable Bar fixing 2515S dan mm dan L2: 4 Clearence hole dia. 6 mm S dan FL: 2 Countersink hole dia. 6 mm Clearence hole dia. 6 dan Stainless F2: 4 Countersink hole dia. 6 mm steel 2515S dan dia. ML: 2 threaded insert M5 3.0 mm 2 Clearence hole dia. 6 mm dan M2: 4 Threaded insert M5 mm S dan FM: 2 Countersink hole dia. 6 2 threaded insert M5 mm dan mm S dan mm dan L2: 4 Clearence hole dia. 6 mm dan FL: 2 Countersink hole dia. 6 mm Clearence hole dia S dan Stainless F2: 4 Countersink hole dia. 6 mm steel dan dia. ML: 2 threaded insert M5 The value indicated corresponds Max to static two points of compression: one point minimum of mm mm and, approx. 2 Clearence one point hole maximum of utile compression. mm dia S dan M2: 4 Threaded insert M5 References & Identifications mm dan FM: 2 Countersink hole dia. 6 2 threaded insert M5 mm S dan mm For Example, Part Number: 2513S 10-08M2 Bar Fixing Number of Loops Type Series Internal Bar Marking: SMAC Work Order Part Number SMAC H000XX 000/00
6 2518S S Part number a b c d e f Mass 2518S 2519S dia. 7 M6 350g to 600g Dimensions in millimeters Descriptions Bars: Aluminum alloy Screws: Inox A2 Threaded insert: Stainless steel Standard treatment: SurTec 650 Number of loops: (W) 8 (standard) Fixing holes: No. 4 Tolerances: Hole ± 0.3 mm Center distances ± 0.5 mm h ± 2.5 mm v ± 3.5 mm Characteristics Transmissibilty: Factor at the resonance ~3 Damping: Damping factor 0.10 to 0.20 Work frequencies: Depend of weight and input level Work configuration: Every orthogonal direction Operating temperature: -180 C to +300 C
7 Technical Features P/Number h v W F 45 Cable Bar fixing 2518S dan mm dan mm S dan mm dan L2: 4 Clearence hole dia. 7 mm S dan FL: 2 Countersink hole dia. 7 mm Clearence hole dia. 7 dan Stainless F2: 4 Countersink hole dia. 7 mm steel 2518S dan dia. ML: 2 threaded insert M6 6.3 mm 2 Clearence hole dia. 7 mm dan M2: 4 Threaded insert M6 mm S dan FM: 2 Countersink hole dia. 7 2 threaded insert M6 mm dan mm S dan mm dan mm The value indicated corresponds to two points of compression: one point minimum of 2 mm and, approx. one point maximum of utile compression.
8 Technical Features P/Number h v W F 45 Cable Bar fixing 2519S dan mm dan mm S dan mm dan L2: 4 Clearence hole dia. 7 mm S dan FL: 2 Countersink hole dia. 7 mm Clearence hole dia. 7 dan Stainless F2: 4 Countersink hole dia. 7 mm steel 2519S dan dia. ML: 2 threaded insert M6 mm mm 2 Clearence hole dia. 7 dan M2: 4 Threaded insert M6 mm S dan FM: 2 Countersink hole dia. 7 2 threaded insert M6 mm dan mm S dan mm dan mm The value indicated corresponds to two points of compression: one point minimum of 2 mm and, approx. one point maximum of utile compression. References & Identifications For Example, Part Number: 2519S 10-08M2 Bar Fixing Number of Loops Type Series Internal Bar Marking: SMAC Work Order Part Number SMAC H000XX 000/00
9 2521S S Part number a b c d e f g i j k Mass 2521S dia. 7 M6 1 to 1.5 kg 2523S dia. 11 M to 4.5 kg 2524S dia. 15 M kg Dimensions in millimeters Descriptions Bars: Aluminum alloy Screws: Inox A2 Threaded insert: Stainless steel Standard treatment: SurTec 650 Number of loops: (W) 8 (standard) Fixing holes: No. 8 Tolerances: Hole ± 0.3 mm Center distances ± 0.5 mm h ± 5 mm v ± 5 mm Characteristics Transmissibilty: Factor at the resonance ~3 Damping: Damping factor 0.10 to 0.20 Work frequencies: Depend of weight and input level Work configuration: Every orthogonal direction Operating temperature: -180 C to +300 C
10 Technical Features P/Number h v W F 45 Cable Bar fixing 2521S dan mm dan mm S dan mm dan L2: 8 Clearence hole dia. 7 mm S dan FL: 4 Countersink hole dia. 7 mm Clearence hole dia. 7 dan Stainless F2: 8 Countersink hole dia. 7 mm steel 2521S dan dia. ML: 4 threaded insert M6 11 mm 4 Clearence hole dia. 7 mm dan M2: 8 Threaded insert M6 mm S dan FM: 4 Countersink hole dia. 7 4 threaded insert M6 mm dan mm S dan mm dan mm The value indicated corresponds to two points of compression: one point minimum of 2 mm and, approx. one point maximum of utile compression. References & Identifications For Example, Part Number 2521S 10-08M2 Bar Fixing Number of Loops Type Series Internal Bar Marking: SMAC Work Order Part Number SMAC H000XX 000/00 :
11 Technical Features P/Number h v W F 45 Cable Bar fixing 2523S dan mm dan mm S dan mm dan L2: 8 Clearence hole dia. 11 mm S dan FL: 4 Countersink hole dia. 11 mm Clearence hole dia. 11 dan Stainless F2: 8 Countersink hole dia. 11 mm steel 2523S dan dia. ML: 4 threaded insert M10 16 mm 4 Clearence hole dia. 11 mm dan M2: 8 Threaded insert M10 mm S dan FM: 4 Countersink hole dia threaded insert M10 mm dan mm S dan mm dan mm S dan mm dan L2: 8 Clearence hole dia. 15 mm S dan FL: 4 Countersink hole dia. 15 mm Clearence hole dia. 15 dan Stainless F2: 8 Countersink hole dia. 15 mm steel 2524S dan dia. ML: 4 threaded insert M14 19 mm 4 Clearence hole dia. 15 mm dan M2: 8 Threaded insert M14 mm S dan FM: 4 Countersink hole dia threaded insert M14 mm dan mm The value indicated corresponds to two points of compression: one point minimum of 2 mm and, approx. one point maximum of utile compression.
12 2525S S Part number a b c d e f g i j k Mass 2525S = 267 = 40 dia. 13 M12 from 10 kg 2526S dia. 19 M18 21 kg Dimensions in millimeters Descriptions Bars: Aluminum alloy Screws: Inox A2 Threaded insert: Stainless steel Standard treatment: SurTec 650 Number of loops: (W) 8 (standard) Fixing holes: No. 8 Tolerances: Hole ± 0.3 mm Center distances ± 0.5 mm h ± 5 mm v ± 7.5 mm Characteristics Transmissibilty: Factor at the resonance ~3 Damping: Damping factor 0.10 to 0.20 Work frequencies: Depend of weight and input level Work configuration: Every orthogonal direction Operating temperature: -180 C to +300 C
13 Technical Features 45 P/Number h v W F Cable Bar fixing 2525S S dan mm dan mm dan mm dan mm Stainless steel dia. 22 mm L2: 8 Clearence hole dia. 13 FL: 4 Countersink hole dia Clearence hole dia. 13 F2: 8 Countersink hole dia. 13 ML: 4 threaded insert M12 4 Clearence hole dia. 13 M2: 8 Threaded insert M12 FM: 4 Countersink hole dia threaded insert M S S dan mm dan mm dan mm dan mm Stainless steel dia mm L2: 8 Clearence hole dia. 19 FL: 4 Countersink hole dia Clearence hole dia. 19 F2: 8 Countersink hole dia. 19 ML: 4 threaded insert M18 4 Clearence hole dia. 19 M2: 8 Threaded insert M18 FM: 4 Countersink hole dia threaded insert M18 The value indicated corresponds to two points of compression: one point minimum of 2 mm and, approx. one point maximum of utile compression. References & Identifications For Example, Part Number 2525S 10-08M2 Bar Fixing Number of Loops Type Series Internal Bar Marking: SMAC Work Order Part Number SMAC H000XX 000/00
14 CONTACT US SMAC Z.I. TOULON EST 66, impasse Branly B.P TOULON CEDEX 9 FRANCE Tél. : Fax : smac@smac.fr FOLLOW US
3. Insert Tocar Sleeves Insert the NCB tissue protection sleeve assembly 1.6 to 10mm through a skin incision (Fig. 38).
NCB Proximal Humerus Plating System Surgical Technique 19 2. Temporary Plate Fixation The plate can be temporary fixed to the bone with 1.6mm K-wire through the proximal cannulated fixation screw of the
More informationKITS KITS. 695 g 759 g. 75 kg 100 kg. Normale
Kit pour prothèse tibiale provisoire k temporary kit GTP200 Cet ensemble permet un réglage en translation et en angulation de la prothèse. llows angulation and shifting adjustment of the prosthesis. GTP100
More informationRiGO801 Laboratory Requirements
RiGO801 Laboratory Requirements 2015-11-25 Air Conditioning According to EN 13032 1 and LM-79-08 the temperature in the environment of the DUT needs to be 25 C +/- 1 C during the measurement. EN 13032-4
More informationANATOMIC LOCKED PLATING SYSTEM
ANATOMIC LOCKED PLATING SYSTEM There is only one...dvr Anatomic. There is only one... ANATOMIC LOCKED PLATING SYSTEM Distal Tibia TiMAX for strength, biocompatibility and enhanced imaging capabilities
More informationCHARLOTTE. 7.0 Multi-Use Compression Screw System SURGICAL TECHNIQUE
CHARLOTTE 7.0 Multi-Use Compression Screw System SURGICAL TECHNIQUE Contents Chapter 1 1 Chapter 2 2 2 3 4 Appendix A 5 6 Appendix B 7 8 Preoperative Planning Surgical Technique Subtalar Arthrodesis Guide
More informationADAPTER IECEx-ATEX, RNC, IP66 / 68, NICKEL PLATED BRASS
ADAPTER IECEx-ATEX, RNC, IP66 / 68, NICKEL PLATED BRASS Anamet IECEx-ATEX adapter fitting, type RNC and RAC, nickel plated brass Type RNC IECEx-ATEX approved 45 or 90 nickel plated brass adapter, male
More information1. Product Name. 2. Product Code. 3. Colour. 4. Brief Description. 5. Contents. 6. Snoezelen Stimulations. Single Panel Porter.
1. Product Name Single Panel Porter 2. Product Code 18518 3. Colour As shown 4. Brief Description One panel can be used at one time and placed anywhere in a room. 5. Contents 1 x Porter 4 x Screws Please
More informationModular Structural Parts Knee Joints
Prosthetic knee joint systems are used to replace the missing healthy knee joint. Their design must therefore meet very high technical demands in order to enable the amputee to live a carefree life again.
More informationFittings & Accessories
Fittings & Accessories Adalet offers a range of fittings and accessories for use in general purpose or industrial locations. These fittings and accessories are used in conjunction with our industrial electrical
More informationDARCO MFS. Locked plating system for reconstructive forefoot surgery.
DARCO MFS Locked plating system for reconstructive forefoot surgery. DARCO MFS Locked plating system for reconstructive forefoot surgery System Basics The DARCO MFS plating system for the forefoot has
More informationO.S.2-C & O.S.2-V. Static Staple - Stainless steel
O.S.2-C & O.S.2-V Compression Staple PEEK Static Staple - Stainless steel 2 O.S.2 - TABLE OF CONTENTS O.S.2-C 3 Product description 4 Indications 8 Surgical technique 9 O.S.2-V 13 Product description 14
More information...vibration isolation. Mounts
...vibration isolation ov-mounts-divider - Updated - 18-09-2017 Anti-vibration type 1 type 2 h P2103 Rubber on silver zinc plated steel (rubber hardness - 60 Shore A). Provides an elastic support mechanism
More informationFlow - diaphragm / limiter
GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 () 942-9383 - Fax - 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Flow - diaphragm / limiter System Flow Diaphragm limiter Nominal
More informationappreciable (0.15 nm) are also nearly reached at intermediate voltages (0.17 nm at 300 or 400 kv) due to
appreciable investigation Microsc. Microanal. Microstruct. 4 (1993) APRIUJUNE 1993, PAGE 111 111 Classification Physics Abstracts 61.16D 61.16F 07.80 In situ experiments in the new transmission electron
More informationSignet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems
Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems Features Certificate of calibration supplied with all sensors. Universal Mount Custom cell constant programmed into the electronics.
More informationEXTERNAL FIXATION SYSTEM
EXTERNAL FIXATION SYSTEM The Apex Pin Fixation System is a one step procedure reducing insertion time and reducing insertion temperature. There are three types of fixation pins: Self-drilling / Self-tapping
More informationYY Translated English of Chinese Standard: YY
Translated English of Chinese Standard: YY0341-2009 www.chinesestandard.net Sales@ChineseStandard.net YY ICS 11.040.40 C 35 Pharmaceutical Industry Standard of the People s Republic of China YY/T 0341-2009
More informationCategory 5e Shielded Keystone Panel Mount Coupler
Category 5e Shielded Keystone Panel Mount Coupler Category 5e Shielded Keystone Panel Mount Coupler (FACK2S) Features Designed to fit industry standard keystone outlets, wall plates and patch panels High
More informationNEOMIS standard SET. The Neomis set can be used with the Neosys single Use instruments set and the I.B.S. compression screws Ø3.0mm / Ø2.5mm / Ø2.0mm.
NEOMIS standard SET PERCUTANEOUS SINGLE USE INSTRUMENTATION NEOMIS STANDARD set is a sterile, singleuse supportive instrumentation, dedicated for minimally invasive surgery in the forefoot. Complementary
More informationR-Group Finland Oy. RLS Lifting Sockets Technical Manual According to Eurocodes, EU Machinery directive 2006/42/EC and VDI/BV-BS 6205 CE Approved
R-Group Finland Oy RLS Lifting Sockets Technical Manual According to Eurocodes, EU Machinery directive 2006/42/EC and VDI/BV-BS 6205 CE Approved 9.1.2017 2 Table of Contents 1 DESCRIPTION OF THE SYSTEM...
More informationSignet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor
Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Features Test certificate supplied with all sensors Universal Mount Custom cell constant programmed into the
More informationPre-Operative Planning. Positioning of the Patient
Surgical Technique Pre-Operative Planning Decide upon the size and angle of the barrel plate to be used from measuring the x-rays. To maximise the sliding action when using shorter lag screws, the Short
More informationTelya. Varisation staple. Surgical Technique. Irish Distributer: O'Mara Medical Tel
Surgical Technique Indications The varisation is used to stabilize an osteotomy of the great toe proximal phalanx (Akin osteotomy), in order to correct : Hallux valgus interphalangeus, Phalangeal pronation,
More informationCABLE GRIP SYSTEM COMPREHENSIVE CABLE GRIP SYSTEM. Family Ties
CABLE GRIP SYSTEM COMPREHENSIVE CABLE GRIP SYSTEM Family Ties Contoured for Optimal Fit with Proximal Femur The GTR cradles the bone anatomically while the strategically placed proximal and distal fins
More informationAC CENTRIFUGAL FORWARD CURVED FAN 133 x 190
Micromotori Elettrici Svizzera Motor Type AC CENTRIFUGAL FORWARD CURVED FAN 133 x 19 Code: 3.9775 Project code: Poles Stator Impeller Type -4 V 5/6 Hz ~ 1 1 M35 Centrifugal Forward Curved Blade double
More informationAlignment Rod. For intraoperatively confirming correction of the mechanical leg axis.
Alignment Rod. For intraoperatively confirming correction of the mechanical leg axis. Easy to use Accuracy of surgery Reduces X-ray exposure Table of Contents Introduction Alignment Rod 2 Handling Technique
More informationNCB Distal Femur System. Surgical Technique
NCB Distal Femur System Surgical Technique NCB Distal Femur System Surgical Technique 3 Surgical Technique NCB Distal Femur System Table of Contents Introduction 4 Indications 8 Preoperative Planning
More informationIndividual oncological implants
Individual oncological implants Catalogue - individual oncological implants ONCOLOGICAL Materials for implants List of materials MATERIAL ISO ČSN DIN ASTM Stainless steel 5832-1 17350 výběr 17 443 W.Nr.
More informationJNL454 55" STOP. 40kg 88lbs. 140cm. AVF Group Ltd. Hortonwood 30, Telford, Shropshire, TF1 7YE, England. Leaflet No rev00
JNL454 STOP Leaflet No. 465391 rev00 Read through ALL instructions before coencing installation. If you have any questions about this product or issues with installation contact the customer services helpline
More informationThe Vilex FUZETM. Dual Thread Screw & Intramedullary Nail in One Implant. The Ultimate TTC Arthrodesis Internal Fixator
The Vilex FUZETM Dual Thread Screw & Intramedullary Nail in One Implant The Ultimate TTC Arthrodesis Internal Fixator Introduction The Vilex FUZE TM TTC Arthrodesis Compression Nail combines the attributes
More informationSMV Scientific Bone Plate and Screw System Surgical Technique
SMV Scientific Bone Plate and Screw System Surgical Technique Description: The SMV Scientific Bone Plate and Screw System consists of non-locking plates and bone screw fasteners in a variety of lengths,
More informationVariable Angle LCP Locking Technology
BUILDING ON SUCCESS Variable Angle LCP Locking Technology The Evolution of Plating Technology Round Screw Hole Dynamic Compression Plate Limited-Contact Dynamic Compression Less Invasive Stabilization
More informationCHARLOTTE. 7.0 Multi-Use Compression Screw System SURGICAL TECHNIQUE
CHARLOTTE 7.0 Multi-Use Compression Screw System SURGICAL TECHNIQUE Contents Chapter 1 1 Chapter 2 2 Chapter 3 3-9 Chapter 4 10-12 Appendix A 13-14 Design Rationale Screw Behavior Surgical Technique Procedure
More informationMonoloc. Med cable. Locking Compression Plate System LCP 3,5 mm. Supplied in sterile packaging. Key Features &Benefits:
Med cable Monoloc Locking Compression Plate System LCP 3,5 mm Supplied in sterile packaging Key Features &Benefits: Separate locking hole & Compression hole design Unique design for locking screw head
More informationLINESCAPES SYSTEM. Made in Italy
LINESCAPES SYSTEM LINESCAPES SYSTEM Made in Italy 03 Linescapes is a modular system that is completely changing the approach to high performance diffused direct and indirect lighting. The singular modules
More informationSilent Gliss. Roman Blind Systems
Roman Blind Systems 2 Chain Operated Roman Blind System Product Information Simple-to-operate and robust bead chain operation Blind stops at any required height without slippage or the need to lock-off
More informationIntegra. Solustaple Standard staple SURGICAL TECHNIQUE. Uni-Clip Compression staple. Products for sale in Europe, Middle-East and Africa only.
eng Integra Solustaple Standard staple SURGICAL TECHNIQUE Uni-Clip Compression staple Table of Contents Solustaple Standard staple...04 Implants Details...04 Indications...04 Instruments Details...04 Surgical
More informationdesigned to advance the treatment of hip fractures.
designed to advance the treatment of hip fractures. introducing the tfn-advanced proximal femoral nailing system (tfna). the tfna system is a new system designed to solve a wide range of unmet needs for
More informationCompact Distal Radius System. Consolidated solution for Distal Radius Plating Systems
Compact Distal Radius System. Consolidated solution for Distal Radius Plating Systems Designed to allow customized system configurations Variable Angle (VA) and Locking Compression Plate (LCP ) options
More informationDUAL MOBILITY CUP, CEMENTED OR CEMENTLESS
HIP Documentation DUAL MOBILITY CUP, CEMENTED OR CEMENTLESS >>DUAL MOBILITY ACETABULAR CUPS Dual mobility acetabular cup P r Gilles Bousquet invented the concept of dual mobility more than thirty years
More informationAll dimensions are in mm. Plug: Coding Pin: HOODS TOP ENTRY HOODS. NPT Part # NP NP 10.
HA 3&4 Plugs & Receptacles HA 3&4 Housings: Single Lever on Base SCREW TERMINATED INSERTS HA 3 HA 4 All dimensions are in mm. HA 3 HA 4 Plug: 10.40 10.4310 Receptacle: 10.40 10.43 Coding Pin: 10.4513 TOP
More information2.4 mm LCP Volar Column Distal Radius Plates. Part of the 2.4 mm LCP Distal Radius System.
2.4 mm LCP Volar Column Distal Radius Plates. Part of the 2.4 mm LCP Distal Radius System. 12 anatomically shaped volar plates Multiple screw options for fixedangle support to articular surface Combi holes
More informationMultipower. User Guide E S S E N T I A L S T R E N G T H
E L E M E N T E S S E N T I A L S T R E N G T H User Guide The identification plate of and manufacturer, affixed to the frame behind the barbell rack, gives the following details: A B C D E Name and address
More informationVariable Angle LCP Forefoot/Midfoot System 2.4/2.7. Procedure specific plates for osteotomies, arthrodeses and fractures of the foot.
Variable Angle LCP Forefoot/Midfoot System 2.4/2.7. Procedure specific plates for osteotomies, arthrodeses and fractures of the foot. Compression technology Variable angle locking technology Anatomic and
More informationoperative technique Universal Application
operative technique Universal Application Introduction Introduction Building upon the design rationale of the Xia Spinal System, the new Xia Spinal System represents the latest advancement in spinal implant
More informationCS 2.0. Product information. Intelligent innovations for a better life. Presented by: Syntellix AG Schiffgraben Hannover Germany
Presented by: CS 2.0 Product information Syntellix AG Schiffgraben 11 30159 Hannover Germany T +49 511 270 413 50 F +49 511 270 413 79 info@syntellix.com www.syntellix.com Implants are manufactured in
More informationAstrid Modular Forefoot System. Surgical Technique
Astrid Modular Forefoot System Surgical Technique Table of Contents Astrid a System for Surgery of the Forefoot... Scarf Osteotomies...6 Stabilization by Means of Two Parallel Double-Threaded Screws Introduced
More informationAcUMEDr. Anatomic Midshaft Forearm Plates
AcUMEDr Anatomic Midshaft Forearm Plates Anatomic Midshaft Forearm Plates Since 1988, Acumed has been designing solutions to the demanding situations facing orthopaedic surgeons, hospitals and their patients.
More informationDURABILITY, LOW AND HIGH TEMPERATURE BEHAVIOUR OF ULTRA HIGH-PERFORMANCE FIBRE REINFORCED CONCRETE
DURABILITY, LOW AND HIGH TEMPERATURE BEHAVIOUR OF ULTRA HIGH-PERFORMANCE FIBRE REINFORCED CONCRETE Emmanuel Ferrier (1), Laurent Michel (1) and Dominique Corvez (2) (1) LGCIE Site Bohr, Université Claude
More informationCHARLOTTE. Compression Staple
CHARLOTTE Compression Staple CHARLOTTE compression staple surgical technique SURGICAL ADVISORS ROBERT ANDERSON, MD BRUCE COHEN, MD W. HODGES DAVIS, MD Proper surgical procedures and techniques are the
More informationAneurysm Clips: Evaluation of Magnetic Field Interactions With an 8.0 T MR System
JOURNAL OF MAGNETIC RESONANCE IMAGING 12:107 111 (2000) Original Research Aneurysm Clips: Evaluation of Magnetic Field Interactions With an 8.0 T MR System Allahyar Kangarlu, PhD, 1* and Frank G. Shellock,
More informationLiquid level transmitter Type AKS 41 / 41U REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Liquid level transmitter Type AKS 41 / 41U REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3
More informationAcUMEDr. Olecranon Threaded Compression Rod
AcUMEDr Olecranon Threaded Compression Rod Olecranon Threaded Compression Rod Since 1988, Acumed has been designing solutions to the demanding situations facing orthopaedic surgeons, hospitals and their
More informationToeMobile. Surgical Technique. Great Toe Endoprosthesis
Great Toe Endoprosthesis Surgical Technique Merete Medical, Inc. 99 Purchase Street Rye, N.Y. 10580 Phone: 914 967-1532 Fax: 914-967-1542 E-Mail: service@merete-medical.com www.merete-medical.com - Description
More informationThe Flower Forefoot PROCEDURE GUIDE.
The Flower Forefoot PROCEDURE GUIDE www.flowerortho.com The Flower Foot & Ankle Application NC FUSION PLATE 2-HOLE COMPRESSION PLATE TMT FUSION PLATE LAPIDUS FUSION PLATE COMPRESSION T-PLATE, OBLIQUE MTP
More informationIntegra. surgical technique. Advansys Midfoot Plating System. eng. D.L.P. Dorsal Lisfranc Plate. M.L.P. Medial Lisfranc Plate
eng Integra Advansys Midfoot Plating System surgical technique D.L.P. Dorsal Lisfranc Plate M.L.P. Medial Lisfranc Plate Table of Contents Advansys Medial Lisfranc Plate (DLP)... 4 Indications... 4 Contraindications...
More informationORTHOPAEDICS & M MEDICAL DEVICES GENERAL CATALOGUE
ORTHOPAEDICS OR RTH & M MEDICAL DEVICES GENERAL CATALOGUE 2 GENERAL CATALOGUE INDEX TRAUMA PRODUCT CATALOGUE NEW GENERATION TRAUMA PRODUCTS 4-14 PLATES INTRAMEDULLARY NAILS EXTERNAL FIXATORS 15-76 77-95
More informationA Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >
A Higher Level of Performance Data Sheet Centurion Guided Radar CGR Series For more information, please visit > www.hawkmeasure.com / Dimensions Centurion Guided Wave Radar Radar Principle of Operation
More information7% - 15% Single Tunnel Repair of Plantar Plate. Savings of. are common with EcoSMART *Patent Pending
* Provide Value Sterile kit packaging provides high quality, surgical grade instruments and implants making your O.R. more efficient. No hassles or expense from cleaning, storing, sterilizing, and maintaining
More informationExternal Skeletal Fixation (ESF)
External Skeletal Fixation (ESF) Technique for fracture repair in animals Introduction External Skeletal Fixation is a versatile and effective technique for fracture repair in animals, rigidly stabilizing
More informationLCP Distal Femur Plates. Shape based on Distal Femur LISS Plate design.
LCP Distal Femur Plates. Shape based on Distal Femur LISS Plate design. Preshaped plate Round threaded holes in plate head Combi holes in plate shaft LCP Distal Femur Plates Plates The LCP Distal Femur
More informationImproving Fixation of a Previously Designed Pediatric Tibial Stent
Improving Fixation of a Previously Designed Pediatric Tibial Stent Evan Lange, Karl Kabarowski, Tyler Max, Sarah Dicker, Lida Acuña-Huete Client: Dr. Matthew Halanski, MD Advisor: Dr. Wan-Ju Li, PhD Biomedical
More informationCS 2.7. Product information. Intelligent innovations for a better life. Presented by: Syntellix AG Aegidientorplatz 2a Hannover Germany
Presented by: CS 2.7 Product information Aegidientorplatz 2a 30159 Hannover Germany T +49 511 270 413 50 F +49 511 270 413 79 info@syntellix.com www.syntellix.com Implants are manufactured in Germany in
More informationThe Do s and Don ts of Pressure Transducers
The Do s and Don ts of Pressure Transducers ABSTRACT When specifying a pressure transducer for a process measurement, a number of items have to be considered. Some of the more important ones are discussed
More informationAreamaster 250/400 Integrally Ballasted Floodlights 100 W to 400 W HID For hazardous and marine locations.
Lighting HID NEC/CEC ENCLOSED AND GASKETED CLASS/ZONE RATED FLOODLIGHT Applications Powerful, efficient weatherproof lighting for medium and large areas such as: Pulp and paper mills Processing plants
More informationLCP Metaphyseal Plate for distal medial tibia. Anatomically precontoured metaphyseal plate.
Indications The LCP Metaphyseal Plate for distal medial tibia is a preshaped plate that allows optimal treatment of juxta-articular fractures of the distal tibia extending into the shaft area. This plate
More informationV New HGP 20. Standard grippers 7.5. Economical and versatile. Self centring. Choice of gripping action. Standard grippers.
V New HGP 20 Economical and versatile Self centring Choice of gripping action 2004/10 Subject to change Products 2004/2005 1 / 1 Key features HGD HGP 06 HGP... B HGR HGW System product for handling and
More informationMEDICAL ADVANCED TECHNOLOGY FOOT SURGERY: COMPRESSION AND VARISATION STAPLE SYSTEM FOOT SURGERY STAPLE FIXATION
MEDICAL ADVANCED TECHNOLOGY FOOT SURGERY: COMPRESSION AND VARISATION STAPLE SYSTEM FOOT SURGERY STAPLE FIXATION FOOT SURGERY STAPLE FIXATION Design rationale & Main features Progressive controlled compression
More information2.0. The Unrivaled Solution for MidFoot Fusion. Reinforced Bone Bridge. Zero Profile. Because Uniform Compression is Better Compression
2.0 The Unrivaled Solution for MidFoot Fusion Uniform Compression Reinforced Bone Bridge Zero Profile Enhanced Implants Refined Instrumentation Efficient Technique Because Uniform Compression is Better
More information2.7 mm/3.5 mm LCP Distal Fibula Plate System. Part of the Synthes locking compression plate (LCP) system.
2.7 mm/3.5 mm LCP Distal Fibula Plate System. Part of the locking compression plate (LCP) system. Anatomically contoured Multiple screw options for fixedangle support Coaxial holes minimize screw head
More informationCS 2.0. Product information. Intelligent innovations for a better life.
CS 2.0 Product information Intelligent innovations for a better life. 02. 03 Syntellix AG MAGNEZIX Compression Screw 2.0 Introduction CAUTION This product description is not sufficient or adequate to allow
More informationSurgical Technique International Version. Clavicle Locking Plate
Surgical Technique International Version Clavicle Locking Plate PERI-LOC Upper Extremity Locked Plating System Clavicle Surgical Techniquefor Table of Contents Introduction........................................................2
More informationGRAFTEK. Pre-implant surgery
GRAFTEK Pre-implant surgery Table of contents Self-drilling screws 4 Self-drilling compression screws 5 Ancillary instruments Drill bits and shafts 6 Screwdriver and container 7 Performance for your expertise...votre
More informationNeedle Valves Catalog 4110-NV December 2010
Needle Valves Catalog 4110-NV December 2010 Series Needle Valves Catalog 4110-NV Introduction Parker Series nion onnet Valves have been engineered for use at pressures up to 6,000 (414 bar) and temperatures
More informationA unique pocket design preventing slugs as the drill exits the component. This allows stacked plates and welded assemblies to be drilled.
POSIDRILL PLUS Stellram s new Posidrill Plus system offers excellent performance in shorthole drilling. The body and insert combination offer an unbeatable combination for 2x or 3x diameter shorthole drilling.
More information3.5 mm LCP Tibial Plateau Sets. Configuration options.
3.5 mm LCP Tibial Plateau Sets. Configuration options. Multiple trays Multiple levels Multiple options 3.5 mm LCP Tibial Plateau Sets The tibial plateau trays allow the hospital to build a custom - ized
More informationFlower Medium Headless & Cannulated Screws
Flower Medium Headless & Cannulated Screws PROCEDURE GUIDE www.flowerortho.com The Flower Foot & Ankle Application NC FUSION PLATE 2-HOLE COMPRESSION PLATE TMT FUSION PLATE LAPIDUS FUSION PLATE COMPRESSION
More informationRUBBER WATERBLAST HOSES
up to 15, PSI (1 Bar) RUBBER WATERBLAST HOSES These high pressure hose assemblies combine rugged construction, dependability and safe performance. Designed specifically for waterblast applications Lightweight
More informationMEDICAL CORPORATION Asbury Rd., P.O. Box 758, Farmingdale, NJ USA Fax
MEDICAL CORPORATION 5206 Asbury Rd., P.O. Box 758, Farmingdale, NJ 07727 USA 732-938-2266 800-323-4035 Fax 732-938-2399 MYO/WIRE Temporary Cardiac Pacing Wire System MYO/WIRE temporary cardiac pacing wires.
More informationCam & Groove Fittings. King Nipples
Cam & Groove Fittings King Nipples Index Aluminum Type A, Male Adapter x Female NPT...3 Type B, Female Coupler x Male NPT...3 Type C, Female Coupler x Hose Shank...4 Type D, Female Coupler x Female NPT...4
More informationSilent Gliss. Cord Operated Curtain Track Systems
Cord Operated Curtain Track Systems 2 Cord Operated Curtain Track System Product Information Strong and elegant, the most attractive heavy duty track available Roller glider glides on rim of front channel
More informationManulife Vitality. Condensed brand guidelines
Manulife Vitality Condensed brand guidelines October 2016 Table of contents Use of Vitality in text...3 When to use Vitality in italics...3 When italics are not required...3 Disclaimers...4 Trademarks...5
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 8157 NORME INTERNATIONALE Second edition Deuxième édition 2015-07-01 Fertilizers and soil conditioners Vocabulary Engrais et amendements Vocabulaire Reference number Numéro de
More informationBODY STRONG FITNESS FINLAND Golf Coat Oy Karvaamokuja 4, Helsinki Finland Tel (0)
BODY STRONG FITNESS FINLAND Golf Coat Oy Karvaamokuja 4, 00380 Helsinki Finland Tel. +358 (0)400 819 007 ITEM NUMBER PICTURE PRODUCT NAME DESCRIPTION UNIT PRICE ALV0% IR3402 Urethane Dumbbell 2.-80kg,
More informationCompression Screw 3.2 Bioabsorbable. Product information
Compression Screw 3.2 Bioabsorbable Product information Caution The current product description is not sufficient for the immediate application of instruments and implants. Instructional training by an
More informationversatile SOLUTION for COMPLEX fractures
hand plating system versatile SOLUTION for COMPLEX fractures hand plating system hps provides everything you need to treat the personality of the fracture. hps includes 53 different plates, 5 screw designs,
More informationversatile SOLUTION for COMPLEX fractures
hand plating system versatile SOLUTION for COMPLEX fractures hps advantages Minimizing soft tissue irritation and adhesions The hps plates are highly polished to reduce surface microroughness, resulting
More informationST SERIES. design, development, production made in Germany
ST SERIES design, development, production made in Germany ST 01 - Crunch Bench ST 02 - Push-up Bars ST 03 - Pull-up Bars ST 04 - Back Bench ST 05 - Balance Board ST 06 - Stretching Bars SE ST 01 - Crunch
More informationupper extremity fixation system
upper extremity fixation system fully disposable fixation system InstaFix in the open position Bi-cortical compression when staple is implanted The InstaFix system is a body temperature activated shape
More informationINSTRUCTION MANUAL (MAN-70254)
INSTRUCTION MANUAL (MAN-70254) CLEVELAND-KIDDER ULTRA SERIES UNDER PILLOW BLOCK TRANSDUCER MODELS: UPB1 & UPB2 REVISION AA Industrial Products Division 7550 Hub Parkway Cleveland, Ohio 44125 Phone: 216.524.8800
More informationINTRAMEDULLARY NAILING TIBIA AND FEMUR 1.3 TIBIAL AND FEMORAL NAILING FEMORAL NAILING WITH RETROGRADE INSERTION IMPLANTS AND OPERATING MANUAL
1.3 TIBIA AND FEMORA NAIING FEMORA NAIING WITH RETROGRADE INSERTION IMPANTS AND OPERATING MANUA INTRAMEDUARY NAIING TIBIA AND FEMUR Medical Products Manufacturing and Trading td. General informations
More informationSERVING THE DEWATERING MARKETS
ELECTRIC ELECTRIC SERVING THE DEWATERING MARKETS ABOUT MODY, INC..... The Initial Start in India. The roots of Mody Pumps, Inc. began in India in 1957, almost 5 years ago by D.N. Mody; a successful businessman
More informationLow Row. User manual E S S E N T I A L S T R E N G T H
E L E M E N T E S S E N T I A L S T R E N G T H User manual 1 The identification plate of and manufacturer, affixed on the back panel of the weight stack, gives the following details: A B C D E Name and
More informationRATCHETS RATCHET ACCESSORIES DENTAL PRODUCTS PRODUCT CATALOG A company of the KLINGEL GROUP
RATCHETS RATCHET ACCESSORIES DENTAL PRODUCTS PRODUCT CATALOG 0 A company of the KLINGEL GROUP Contents Universal ratchet without torque function General information All ratchets are available with different
More informationPEEK SS Columns & Guard Columns
PEEK SS Columns & Guard Columns ~ Stainless Steel Analytical Columns ~ PEEK Columns ID 2.1, 4.0, 4.6 & 7.5 mm ~ Jour-Guard Cartridges Stainless Steel or PEEK ~ Stainless Steel End Fittings 1/4 OD Columns
More informationTechnique Guide Small Bone Fusion System
Technique Guide Small Bone Fusion System The Pinit Plate Small Bone Fusion System is a super low profile, modular bone plate and screw system designed to stabilize a bunionectomy with a medial to lateral
More informationMisc: Interchange Coupling
Wing Style Interchange Coupling Misc: Interchange Coupling Series: W Interchange: Parker 6100 - Seals: Nitrile - Threaded sleeve allows connection/disconnection under pressure - Coupler: brass material
More information3.0/3.5/4.0/4.5/6.5/7.0/7.3. Cannulated Screws. Surgical Technique
3.0/3.5/4.0/4.5/6.5/7.0/7.3 Cannulated Screws Surgical Technique Image intensifier control This description alone does not provide sufficient background for direct use of DePuy Synthes products. Instruction
More informationACTIV ANKLE DISTAL TIBIA PLATE MEDIAL MALLEOLUS INNOVATION MEANS MOTION. DUALTEC SYSTEM II and III
INNOVATION MEANS MOTION ACTIV ANKLE DISTAL TIBIA PLATE MEDIAL MALLEOLUS POLYAXIAL LOCKING FIXATION DUALTEC SYSTEM II and III Precontoured implants Polyaxiality of 20 2 types of plates: hook and standard
More informationPRODUCT SCHEDULE FOR CERTIFICATE CE JRI ORTHOPAEDICS LIMITED
HIP STEM (Class III) Active Stem Active H-AC Stem / 09mm - 16mm Cemented Hemiarthroplasty (formally LOL 127) Cemented Hemiarthroplasty Stem / X-X-Small - Large Cemented Hemiarthroplasty Stem - Long / Small
More information