High-Spatial-Resolution 3D Balanced Turbo Field-Echo Technique for MR Angiography of the Renal Arteries: Initial Experience 1

Size: px
Start display at page:

Download "High-Spatial-Resolution 3D Balanced Turbo Field-Echo Technique for MR Angiography of the Renal Arteries: Initial Experience 1"

Transcription

1 Kenneth L. Coenegrachts, MD Romhild M. Hoogeveen, PhD Johan A. Vaninbroukx, MD Hilde T. Bosmans, PhD Didier J. Bielen, MD Geert Maleux, MD Frederik Maes, PhD Pascal Hamaekers Raymond H. Oyen, MD, PhD Guy J. Marchal, MD, PhD Index terms: Magnetic resonance (MR), threedimensional, Magnetic resonance (MR), vascular studies, Renal arteries, stenosis or obstruction, , Published online before print /radiol Radiology 2004; 231: Abbreviations: DSA digital subtraction angiography MIP maximum intensity projection 3D three-dimensional 1 From the Department of Radiology (K.L.C., J.A.V., H.T.B., D.J.B., G.M., P.H., R.H.O., G.J.M.) and Laboratory of Medical Imaging Research (F.M.), University Hospitals Gasthuisberg, Herestraat 49, B-3000 Leuven, Belgium; and Philips Medical Systems, Best, the Netherlands (R.M.H.). Received January 11, 2003; revision requested March 24; final revision received August 4; accepted September 29. Address correspondence to K.L.C. ( kcoenegrachts74@yahoo.com). Author contributions: Guarantors of integrity of entire study, K.L.C., H.T.B., R.H.O., G.J.M.; study concepts and design, K.L.C., H.T.B., R.H.O., G.J.M.; literature research, K.L.C., H.T.B.; clinical studies, K.L.C., J.A.V., G.M., P.H.; data acquisition, K.L.C., P.H.; data analysis/interpretation, K.L.C., R.M.H., H.T.B., D.J.B., G.M.; statistical analysis, K.L.C., F.M.; manuscript preparation, K.L.C., H.T.B.; manuscript definition of intellectual content, K.L.C., H.T.B., R.H.O., G.J.M.; manuscript editing, K.L.C., H.T.B.; manuscript revision/review, J.A.V., R.H.O., G.J.M.; manuscript final version approval, H.T.B., G.J.M. RSNA, 2004 High-Spatial-Resolution 3D Balanced Turbo Field-Echo Technique for MR Angiography of the Renal Arteries: Initial Experience 1 PURPOSE: To compare a multislab balanced turbo field-echo magnetic resonance (MR) angiographic technique, without the use of a contrast agent, with digital subtraction angiography (DSA) for imaging of the renal arteries. MATERIALS AND METHODS: Twenty-five randomly selected patients (eight women and 17 men; age range, years; mean age, 72 years) suspected of having renal artery stenosis underwent both DSA and balanced turbo field-echo MR angiography. A consensus result was obtained among three radiologists in evaluation of main renal arteries on balanced turbo field-echo images and DSA images. Sensitivity, specificity, and negative and positive predictive values of the balanced turbo field-echo technique were calculated, and receiver operating characteristic analysis was performed for depiction of hemodynamically significant stenosis. Cohen analysis was used to assess agreement between the two imaging methods in grading of stenoses and depiction of significant stenosis. Accessory renal arteries also were evaluated. RESULTS: Fifty main renal arteries and 11 accessory arteries were fully depicted with DSA. DSA depicted 11 stenotic lesions in the main renal arteries. In comparison, enabled visualization of 46 of 50 main renal arteries to their first branching points and depicted 10 of 11 accessory arteries. Sensitivity, specificity, negative predictive value, and positive predictive value of this technique for depiction of significant stenosis were 100% (four of four), 98% (41 of 42), 100% (41 of 41), and 80% (four of five), respectively. The area under the receiver operating characteristic curve was was for grading of stenoses and for depiction of significant stenosis. CONCLUSION: Multislab balanced turbo field-echo imaging has potential as an MR angiography technique for depiction of normal and diseased renal arteries. RSNA, 2004 The current state-of-the-art magnetic resonance (MR) angiographic technique for renal artery imaging involves the application of a fast gradient-echo sequence during intravenous injection of a T1 contrast agent. Several studies in which contrast-enhanced MR angiography was compared with digital subtraction angiography (DSA) have established the value of contrast-enhanced MR angiography (1 7). Some authors have concluded that contrast-enhanced MR angiography can be used to screen for renovascular disease (8). Compared with contrast-enhanced MR techniques, flow-based MR techniques such as time-of-flight or phase-contrast imaging have never been used successfully for this purpose. One of the main problems has been insufficient vessel to soft-tissue signal intensity contrast relative to the saturation of the signal of inflowing blood. In addition, relatively long acquisition times made image acquisition during a single breath hold impossible with flow-based techniques. Image blurring was the result. In practice, only the proximal centimeters of the main renal arteries could be successfully visualized (9,10). 237

2 There are several clinical situations in which the use of a contrast agent for MR angiography compromises the quality of other investigations performed during the same MR imaging session. A typical example is the work-up of a patient prior to renal surgery: A single imaging session that includes the acquisition both of a renal perfusion study and of contrast-enhanced MR angiographic images is not optimal for either one or the other of these measurements. The relative invasiveness and cost of the intravenous contrast agent used at MR angiography limit the potential of this technique for large-scale screening. The balanced turbo field-echo MR angiographic technique is based on a gradient-echo sequence in which the gradients are fully balanced without spoiling of the transverse magnetization. The result is a steady-state signal that is nearly independent of the actual repetition time. The signal-to-noise ratio is relatively high even without the use of a contrast agent (11). The short repetition time allows imaging during a single breath hold. High spatial resolution is achieved with the small voxel sizes and dedicated k-space schemes. Because of the specific characteristics of the balanced turbo field-echo technique on the one hand and the relatively high T2/T1 ratio of the blood on the other hand (11,12), blood vessels maintain a hyperintense signal over a longer distance than with conventional time-of-flight techniques. The purpose of our study was to compare a multislab balanced turbo fieldecho MR angiographic technique, without the use of a contrast agent, with DSA for imaging of the renal arteries. MATERIALS AND METHODS Patients Twenty-five patients (eight women and 17 men aged years; mean age of women, 75.6 years 5.8 [SD]; mean age of men, 70.6 years 15.5) who were suspected of having renal artery stenosis and were scheduled for abdominal DSA were randomly selected for additional examination of the renal arteries with balanced turbo field-echo MR angiography. There were no statistically significant differences between the age distributions by sex. Written informed consent was obtained for all patients. Our institutional ethics committee approved our study. MR Imaging Technique All MR examinations were performed with a 1.5-T MR imager (Intera; Philips Medical Systems, Best, the Netherlands). The maximum gradient strength was 30 mt/m. The minimum time taken to reach this gradient amplitude was 200 sec. All examinations were performed with a phased-array body coil. A balanced fast field-echo sequence was applied in the coronal plane for localization of the origin of the main renal arteries and in the sagittal plane for localization of the origin of the superior mesenteric artery. A balanced turbo fieldecho sequence then was applied with the following parameters: repetition time msec/echo time msec, 6.9/3.45; flip angle, 80. The water-fat shift was 0.4 pixel (bandwidth, Hz/pixel). The number of shots was 39. The matrix was reconstructed to a matrix. A field of view of 300 mm and a rectangular field of view of 35% (reduction to 35% in the number of phase encodings) were used. The imaging percentage was 100%. Reconstructed voxel dimensions were mm. Water-selective excitation was performed for fat suppression. Phase wrapping was eliminated in the anteroposterior direction with activation of fold-over suppression (number of signals acquired, two) and caudocephalad with 5% section oversampling. Three saturation pulses were applied prior to each balanced turbo field-echo shot to provide venous signal suppression (Fig 1). Two saturation slabs covered the hilum of each kidney. A third saturation slab was positioned parallel and caudal to the three-dimensional (3D) imaging volume at a distance of 10 mm to provide suppression of signal from the inferior vena cava. The acquisition time per 3D slab was 21 seconds. Breath holding was performed at end expiration. The acquisition protocol consisted of two measurements: a single-slab acquisition at the level of the main renal arteries, and a multislab acquisition (multiple overlapping thin-slab acquisitions, or MOTSA) that covered the arterial anatomy from the origin of the superior mesenteric artery to the aortic bifurcation. Total imaging time was less than 10 minutes per patient. After acquisition of the 3D MR angiographic data, maximum intensity projection (MIP) images in different planes were obtained at the main console of the MR imaging unit by using the standard tools. Conventional angiography was preceded by sterile preparation of the groin with a 70% alcohol solution containing 0.5% chlorhexidine. Angiography was performed with local anesthesia by using a 1% xylocaine solution (Astra Zeneca, Brussels, Belgium). Prior to puncture of the femoral artery, a small cutaneous incision was made with a no. 11 surgical blade (Swann-Morton, Sheffield, England) held flat. Either a single arterial wall puncture or the Seldinger technique was used with a needle-styletted 18- gauge intravenous catheter (SurFlash; Terumo, Louvain, Belgium). After introduction of a inch, 150-cm, angledtip hydrophilic guide wire (Kayak; Boston Scientific Medi-Tech, Natick, Mass), a 5-F, 150-cm-long sheath (Radiofocus Introducer II; Terumo) was inserted, along which a calibrated pigtail catheter (Royal Flush; Cook, Winston-Salem, NC) was advanced to the estimated level of the ostium of the renal arteries. An anteroposterior view and two oblique projections at an angle of approximately 45 were obtained during the injection of 30 ml of iobitridol (Xenetix 300; Codali Guerbet, Brussels, Belgium), a nonionic contrast agent containing 300 mg of iodine per milliliter, at a rate of 15 ml per second by using an injector (Mark V Plus; Medrad, Indianola, Pa). Angiography was performed with a C-arm system (Integris 3000; Philips Medical Systems). MR angiography and DSA were performed within 1 week of each other, with MR angiography preceding DSA in all cases. Image Evaluation All images were evaluated independently by three vascular radiologists (J.A.V., D.J.B., G.M., with 6, 16, and 11 years of experience, respectively, in the interpretion of MR angiography and DSA studies). All MR images were stored on optical disk and reviewed at a picture archiving and communication system workstation (Agfa, Antwerp, Belgium). In a first session, the balanced turbo field-echo images were evaluated. To prevent bias, the images from the different patients were presented in random order. The DSA images were evaluated in a second session 2 weeks after the first session. In cases of disagreement among the three evaluating radiologists, a final evaluation was performed by consensus in a third evaluation session. A third evaluation session was performed for images from one patient. Images were evaluated for depiction of the entire main renal artery to the point of its branching into the segmental arteries at the level of the renal hilum. Detection of stenosis at the level of the main renal arteries was recorded. Ostial loca- 238 Radiology April 2004 Coenegrachts et al

3 Figure 1. Coronal (left), transverse (upper right), and sagittal (lower right) images from balanced fast field-echo MR imaging show the positioning of the 3D acquisition volume at the level of the main renal arteries, the two saturation slabs over the hila of both kidneys, and the third saturation slab parallel and caudal to the acquisition volume at a distance of 10 mm. tion of stenosis was defined as location within 5 mm of the origin of the main renal artery; nonostial location was defined as location more than 5 mm from the origin of the main renal artery. Detected stenoses were classified in four groups according to grade (ie, percentage of reduction in luminal diameter): less than 50%, 50% 80%, more than 80%, and occlusion. All detected stenoses were measured with calipers on the images. Images also were evaluated for depiction of accessory renal arteries. In addition, the source images and MIP images obtained with balanced turbo field-echo MR angiography were assessed for artifacts. Motion artifacts were evaluated as absent, present without degradation of diagnostic quality, or present with degradation of diagnostic quality. Saturation of the venous signal and overlapping hyperintensities in the surrounding tissues were assessed as either absent or present. Statistical Analysis For statistical analysis, each stenosis grade was assigned an ordinal score. Absence of stenosis was assigned a score of 0, stenosis of less than 50% was assigned a score of 1, stenosis of 50% 80% was assigned a score of 2, stenosis of more than 80% was assigned a score of 3, and occlusion was assigned a score of 4. Sensitivity, specificity, negative predictive value, and positive predictive value of as a diagnostic test for renal artery stenosis were calculated for all main renal arteries evaluated for stenosis. Receiver operating characteristic analysis was performed for evaluation of all main renal arteries for hemodynamically significant stenosis. DSA was the method of reference. Because stenoses of more than 80% were considered hemodynamically significant, grades 0 2 were regarded as negative test results for renal artery stenosis and grades 3 and 4 were regarded as positive test results for renal artery stenosis. The Cohen analysis was used to test for agreement between balanced turbo fieldecho MR angiography and DSA with respect to grade of stenosis and with respect to the presence or absence of hemodynamically significant stenosis. RESULTS DSA depicted 50 main renal arteries in 25 patients. Eleven stenotic lesions, six with ostial locations and five with nonostial locations, were detected. In another patient, a string-of-beads pattern compatible with fibromuscular dysplasia was detected on the right side. The results of stenosis grading with DSA and with balanced turbo field-echo MR angiography are shown in the Table for 46 of 50 main renal arteries. The Table does not include grading results from one patient who was uncooperative and in whom the main renal arteries, which appeared normal on DSA images, could not be evaluated with balanced turbo field-echo imaging. In addition, results from the patient with fibromuscular dysplasia are not shown in the Table. Eleven accessory renal arteries one in each patient with detected stenosis were depicted with DSA. Balanced turbo field-echo MR angiography successfully depicted 46 of 50 main renal arteries at least to the point of their branching into the segmental arteries (Fig 2). Two main renal arteries were not depicted because the patient was uncooperative during MR angiography. In the remaining two main renal arteries, the part of the main artery that was distal to a high-grade stenosis could not be visualized until the branching point. All 11 stenotic lesions were detected and accurately localized with the balanced turbo field-echo technique, which Volume 231 Number 1 MR Angiography of Renal Arteries 239

4 Comparison of Grading with Both Balanced Turbo Field-Echo MR Angiography and DSA in 46 Main Renal Arteries Grade at Balanced Turbo Field-Echo MR Angiography No 50% also correctly depicted the abnormalities in the patient with fibromuscular dysplasia (Fig 3). This patient was not evaluated further for stenosis grading. The results of stenosis grading with versus DSA are shown in the Table. With balanced turbo field-echo imaging, seven of 11 stenotic lesions were correctly graded (Fig 4); there was disagreement, however, in the grading of four stenotic lesions. Results with the balanced turbo field-echo technique were the same as those with DSA in 42 of the 46 main renal arteries evaluated for stenosis, including all 35 main renal arteries with no stenosis, three with stenosis of less than 50%, and four with stenosis of more than 80%. The results of stenosis grading with differed from those with DSA in four main renal arteries with stenotic lesions (the same four of 11 mentioned in the preceding paragraph). Although the results of stenosis grading with the balanced turbo field-echo technique were wrong in these four arteries, the grading error in three of the arteries would have had no influence on patient work-up (Table). The results of stenosis grading and the diagnostic work-up based only on were wrong in one main renal artery. In the assessment of all 46 main renal arteries for the presence of significant stenosis, had a sensitivity, specificity, negative predictive value, and positive predictive value of four of four (100%), 41 of 42 (98%), 41 of 41 (100%), and four of five (80%), respectively. The area under the receiver operating characteristic curve was (standard error, 0.039; 95% CI: 0.901, 0.994). With respect to the presence or absence of significant stenosis, the value was (95% CI: 0.639, 1.115). With respect to grade of stenosis, the value was (95% CI: 0.578, 0.986). Balanced turbo field-echo Grade at DSA 50% 80% MR angiography also depicted 10 of 11 accessory renal arteries (Fig 5). In 22 of 25 patients, there was no visible motion degradation of the source images. On images from two patients, motion degradation was present, but the images were considered diagnostically useful. One study was nondiagnostic because of motion degradation. In all but one patient, there was complete saturation of the venous signal. On the other hand, the MIP images were mostly of poor quality due to overlapping hyperintensities from surrounding tissues. DISCUSSION 80% Occlusion No stenosis % stenosis % 80% stenosis % stenosis Occlusion Balanced turbo field-echo imaging belongs to the same category as the earlierintroduced time-of-flight techniques. Because of the specific features of the balanced turbo field-echo technique and the relatively high T2/T1 ratio of the blood, blood vessels show hyperintense signal over a longer distance with balanced turbo field-echo imaging than with conventional time-of-flight techniques. The application of water-selective excitation is crucial to obtain good fat suppression. The unique property of balanced turbo field-echo techniques the splitting of the train of radiofrequency pulses into several trains of balanced turbo field-echo pulses (balanced turbo field-echo shots) is crucial for venous signal suppression. With the proposed use of saturation pulses, the balanced turbo field-echo technique allows robust saturation of the signal coming from blood in the renal veins and the inferior vena cava. Acquisition of volumes in the transverse plane is preferred to maximize the inflow effect, as in time-of-flight studies in the brain, in which multiple overlapping thin slabs are routinely acquired if the whole brain must be imaged (13). The shortest possible repetition time and echo time are used: A short echo time is Figure 2. (a) Source image from balanced turbo field-echo (6.9/3.45; flip angle, 80 ) MR angiography shows two normal main renal arteries at the level of their branching into the segmental and intrarenal arteries. (b) Corresponding coronal MIP image and (c) coronal image from DSA show the main renal arteries (arrows). A fluid accumulation in the bile duct (arrowhead) degrades the MIP image. Figure 3. (a) Source image from balanced turbo field-echo (6.9/3.45; flip angle, 80 ) MR angiography and coronal image from DSA show a string-of-beads pattern (arrow) indicative of fibromuscular dysplasia in the distal right main renal artery. used to minimize flow-induced dephasing, and a short repetition time guarantees an acceptable acquisition time. 240 Radiology April 2004 Coenegrachts et al

5 Figure 4. (a) Source image and corresponding (b) coronal MIP image from balanced turbo field-echo (6.9/3.45; flip angle, 80 ) MR angiography and (c) coronal image from DSA show a stenotic lesion (arrow) in the ostium of the left main renal artery. Theoretically, the extent of the segment of the renal arteries visualized with the balanced turbo field-echo technique still partly depends on the inflow saturation effect. The amount of saturation is much smaller with the balanced turbo field-echo technique than with time-offlight methods because of intrinsic preservation of the transverse magnetization. Saturation is not problematic for evaluation of the main renal arteries in either young or old patients on source images acquired with the balanced turbo fieldecho technique, compared with the previously used flow-based techniques (time-of-flight and phase-contrast imaging). This finding is remarkable because only the first few proximal centimeters of the main renal arteries could be visualized with these earlier techniques on a routine basis (9,10). The correct grading of stenoses has always been a challenge with MR angiography. Time-of-flight techniques tend to lead to overestimation of stenosis because of signal dispersion in turbulent flow. This situation is aggravated in phase-contrast imaging. Contrast-enhanced MR angiography is less sensitive to this effect because the echo time is extremely short. In a recent study, Saloner et al (14) found that even with contrast-enhanced MR angiography, grading of stenoses might be incorrect. A true reference standard may be intraoperative measurement. Ex vivo validation can be based on casts made from specimens, as proposed by Saloner et al (14). Specimens were not available to us, however, because most of the patients in our study did not undergo renal artery surgery. DSA was chosen as the reference standard. This study shows that it is feasible to correctly grade stenotic lesions of different severity with the balanced turbo field-echo technique, although there is a tendency to overestimate stenoses with this technique, compared with DSA. This can be explained by a dephasing effect at the level of stenosis that is similar to known effects in time-of-flight and phase-contrast techniques. In the balanced turbo field-echo sequence, echo time is as short as possible to minimize its sensitivity to dephasing effects. There is no clear explanation for the underestimation of one stenosis with balanced turbo field-echo MR angiography. In four of 50 main renal arteries in this study, imaging with the balanced turbo field-echo technique was suboptimal. In two main renal arteries, depiction was poor because the patient was uncooperative. In two main renal arteries, the part of the main renal artery distal to a highgrade stenosis could not be visualized until the point of branching into the segmental arteries. A dephasing effect at the level of these stenoses and a loss of sufficient inflow could explain the loss of signal in the main renal artery distal to the stenosis. In such cases, use of the balanced turbo field-echo technique for initial evaluation may result in a need for additional angiographic examinations that would have been obviated by use of contrast-enhanced MR angiography. evaluation with the balanced turbo field-echo sequence resulted in neither false-positive nor false-negative findings. This fact is important for the comparison of this technique with previously used flow-based techniques (time-of-flight and phase-contrast imaging), because many false-positive results in the past were caused by flow artifacts (9,15,16). The combination of a good inflow effect and a good T2/T1 ratio of the blood can explain these findings. A benefit of the balanced turbo fieldecho sequence is the acquisition speed and the ability to perform imaging during breath holding. The advantages of imaging during breath holding are obvious and include the reduction or avoidance of motion artifacts. The spatial resolution of images acquired with this technique is acceptable overall but may have to be further improved for more accurate assessment of stenoses. The one patient with fibromuscular dysplasia is not a sufficiently large sample from which to draw conclusions concerning the ability of balanced turbo field-echo MR angiography to depict fibromuscular dysplasia. More patients with proved fibromuscular dysplasia at DSA will have to be evaluated with balanced turbo field-echo MR angiography for comparison in future studies. The quality of the MIP images was mostly insufficient because of overlapping hyperintensities from fluid in the intestines, bile in the distal extrahepatic ducts, or fluid in a prominent ureter. In this regard, the source images from balanced turbo field-echo MR angiography are far more important for diagnosis and stenosis grading than are MIP images. More advanced visualization techniques should be used in future MR angiographic examinations with balanced turbo field-echo techniques. The high sensitivity and negative predictive value of balanced turbo field-echo MR angiography for the evaluation of hemodynamically significant main renal artery stenoses suggest that this method may have prospects for use in the screening and selection of patients for interventional DSA of the renal arteries. With respect to grading of stenosis, the value reveals substantial agreement. With respect to depicting the presence of significant stenosis, the value reveals almost perfect agreement. The main limitation of this study is the restricted number of cases. Further clinical studies are needed to confirm these preliminary results. Technical optimizations are needed to improve the quality of the MIP images and the grading of stenoses. A reduction of echo time may further reduce the dephasing effect at the level of stenoses. A further reduction of the acquisition time with, for instance, parallel imaging or more powerful slew Volume 231 Number 1 MR Angiography of Renal Arteries 241

6 Figure 5. (a, b) Source images and (c) corresponding oblique transverse MIP image from balanced turbo field-echo (6.9/3.45; flip angle, 80 ) MR angiography show an accessory right renal artery (arrows). These images exemplify the high spatial resolution achievable with the balanced turbo field-echo technique. (d) Coronal image from DSA confirms the presence and location of the accessory artery (arrows). rates will probably allow improvement of the results in uncooperative patients. The use of a navigator-gated technique might also help to improve image quality in uncooperative patients. An improvement of spatial resolution will probably be of benefit in the evaluation of fibromuscular dysplasia and of stenotic lesions. In conclusion, the balanced turbo fieldecho technique in most cases enabled accurate visualization of the main renal arteries to the point of their branching into the segmental arteries without the use of an intravenous contrast agent. Correlation with DSA was good in the grading of main renal artery stenoses and in the depiction of accessory renal arteries. The balanced turbo field-echo technique presented holds promise for accurate differentiation between normal arteries and arteries with atherosclerotic disease. References 1. Schoenberg SO, Bock M, Knopp MV, et al. Renal arteries: optimization of three-dimensional gadolinium-enhanced MR angiography with bolus-timing-independent fast multiphase acquisition in a single breath hold. Radiology 1999; 211: Masunaga H, Takehara Y, Isoda H, et al. Assessment of gadolinium-enhanced time-resolved three-dimensional MR angiography for evaluating renal artery stenosis. AJR Am J Roentgenol 2001; 176: Van Hoe L, De Jaegere T, Bosmans H, et al. Breath-hold contrast-enhanced three-dimensional MR angiography of the abdomen: time-resolved imaging versus single-phase imaging. Radiology 2000; 214: Maki JH, Chenevert TL, Prince MR. Contrastenhanced MR angiography. Abdom Imaging 1998; 23: Hany TF, Debatin JF, Leung DA, Pfammatter T. Evaluation of the aortoiliac and renal arteries: comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography. Radiology 1997; 204: Schoenberg SO, Knopp MV, Bock M, Prince MR, Allenberg JR. Combined morphologic and functional assessment of renal artery stenosis using gadolinium enhanced magnetic resonance imaging. Nephrol Dial Transplant 1998; 13: Schoenberg SO, Essig M, Bock M, Hawighorst H, Sharafuddin M, Knopp MV. Comprehensive MR evaluation of renovascular disease in five breath holds. J Magn Reson Imaging 1999; 10: Dong Q, Schoenberg SO, Carlos RC, et al. Diagnosis of renal vascular disease with MR angiography. RadioGraphics 1999; 19: Loubeyre P, Revel D, Garcia P, et al. Screening patients for renal artery stenosis: value of three-dimensional time-of-flight MR angiography. AJR Am J Roentgenol 1994; 162: Duda SH, Schick F, Teufl F, et al. Phase-contrast MR angiography for detection of arteriosclerotic renal artery stenosis. Acta Radiol 1997; 38: Hoogeveen RM, Vasbinder B. High-resolution 3D breath-hold inflow balanced-ffe of the renal arteries (abstr). In: Proceedings of the Tenth Meeting of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: International Society for Magnetic Resonance in Medicine, 2002; Scheffler K, Heid O, Hennig J. Magnetization preparation during the steady state: fat-saturated 3D TrueFISP. Magn Reson Med 2001; 45: Davis WL, Warnock SH, Harnsberger HR, Parker DL, Chen CX. Intracranial MRA: single volume vs. multiple thin slab 3D time-offlight acquisition. J Comput Assist Tomogr 1993; 17: Saloner D, Ong K, Rapp JH, and the ACSCEPT investigators. Overestimation of carotid stenosis on contrast-enhanced MRA (abstr). In: Proceedings of the Tenth Meeting of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: International Society for Magnetic Resonance in Medicine, 2002; Lewin JS. Time-of-flight magnetic resonance angiography of the aorta and renal arteries. Invest Radiol 1992; 27(suppl):S84 S Loubeyre P, Cahen R, Grozel F, et al. Transplant renal artery stenosis: evaluation of diagnosis with magnetic resonance angiography compared with color duplex sonography and arteriography. Transplantation 1996; 62: Radiology April 2004 Coenegrachts et al

Essentials of Clinical MR, 2 nd edition. 99. MRA Principles and Carotid MRA

Essentials of Clinical MR, 2 nd edition. 99. MRA Principles and Carotid MRA 99. MRA Principles and Carotid MRA As described in Chapter 12, time of flight (TOF) magnetic resonance angiography (MRA) is commonly utilized in the evaluation of the circle of Willis. TOF MRA allows depiction

More information

Magnetic Resonance Angiography

Magnetic Resonance Angiography Magnetic Resonance Angiography 1 Magnetic Resonance Angiography exploits flow enhancement of GR sequences saturation of venous flow allows arterial visualization saturation of arterial flow allows venous

More information

MR Advance Techniques. Vascular Imaging. Class II

MR Advance Techniques. Vascular Imaging. Class II MR Advance Techniques Vascular Imaging Class II 1 Vascular Imaging There are several methods that can be used to evaluate the cardiovascular systems with the use of MRI. MRI will aloud to evaluate morphology

More information

1Pulse sequences for non CE MRA

1Pulse sequences for non CE MRA MRI: Principles and Applications, Friday, 8.30 9.20 am Pulse sequences for non CE MRA S. I. Gonçalves, PhD Radiology Department University Hospital Coimbra Autumn Semester, 2011 1 Magnetic resonance angiography

More information

Non Contrast MRA. Mayil Krishnam. Director, Cardiovascular and Thoracic Imaging University of California, Irvine

Non Contrast MRA. Mayil Krishnam. Director, Cardiovascular and Thoracic Imaging University of California, Irvine Non Contrast MRA Mayil Krishnam Director, Cardiovascular and Thoracic Imaging University of California, Irvine No disclosures Non contrast MRA-Why? Limitations of CTA Radiation exposure Iodinated contrast

More information

Contrast material enhanced threedimensional

Contrast material enhanced threedimensional Winfried A. Willinek, MD Jürgen Gieseke, PhD Rudolf Conrad, MD Holger Strunk, MD Romhild Hoogeveen, PhD Marcus von Falkenhausen, MD Ewald Keller, MD Horst Urbach, MD Christiane K. Kuhl, MD Hans H. Schild,

More information

Anatomic Evaluation of the Circle of Willis: MR Angiography versus Intraarterial Digital Subtraction Angiography

Anatomic Evaluation of the Circle of Willis: MR Angiography versus Intraarterial Digital Subtraction Angiography Anatomic Evaluation of the Circle of Willis: MR Angiography versus Intraarterial Digital Subtraction Angiography K. W. Stock, S. Wetzel, E. Kirsch, G. Bongartz, W. Steinbrich, and E. W. Radue PURPOSE:

More information

Diagnosis of Vertebral Artery Ostial Stenosis on Contrast-Enhanced MR Angiography: Usefulness of a Thin-Slab MIP Technique

Diagnosis of Vertebral Artery Ostial Stenosis on Contrast-Enhanced MR Angiography: Usefulness of a Thin-Slab MIP Technique Diagnosis of Vertebral Artery Ostial Stenosis on Contrast-Enhanced MR Angiography: Usefulness of a Thin-Slab MIP Technique Sun Mi Kim 1, Deok Hee Lee 2 Jin Woo Choi 3, Byung Se Choi 4, Hyun Sin In 5 It

More information

RECENT ADVANCES IN CLINICAL MR OF ARTICULAR CARTILAGE

RECENT ADVANCES IN CLINICAL MR OF ARTICULAR CARTILAGE In Practice RECENT ADVANCES IN CLINICAL MR OF ARTICULAR CARTILAGE By Atsuya Watanabe, MD, PhD, Director, Advanced Diagnostic Imaging Center and Associate Professor, Department of Orthopedic Surgery, Teikyo

More information

Anatomical and Functional MRI of the Pancreas

Anatomical and Functional MRI of the Pancreas Anatomical and Functional MRI of the Pancreas MA Bali, MD, T Metens, PhD Erasme Hospital Free University of Brussels Belgium mbali@ulb.ac.be Introduction The use of MRI to investigate the pancreas has

More information

Department of Radiology University of California San Diego. MR Angiography. Techniques & Applications. John R. Hesselink, M.D.

Department of Radiology University of California San Diego. MR Angiography. Techniques & Applications. John R. Hesselink, M.D. Department of Radiology University of California San Diego MR Angiography Techniques & Applications John R. Hesselink, M.D. Vascular Imaging Arterial flow void Flow enhancement Gadolinium enhancement Vascular

More information

CT Versus MR for the Runoff

CT Versus MR for the Runoff CT Versus MR for the Runoff Robert R. Edelman, M.D. Dept. of Radiology NorthShore University HealthSystem Feinberg School of Medicine, Northwestern University Magnetic Resonance Computed Tomography Radio

More information

MR Angiography in the evaluation of Lower Extremity Arterial Disease

MR Angiography in the evaluation of Lower Extremity Arterial Disease March 2001 MR Angiography in the evaluation of Lower Extremity Arterial Disease Ted Mau, Harvard Medical School Year III Objectives We will cover: Indications for Magnetic Resonance Angiography (MRA) Basic

More information

Time-resolved Magnetic Resonance Angiography for assessment of recanalization after coil embolization of visceral artery aneurysms

Time-resolved Magnetic Resonance Angiography for assessment of recanalization after coil embolization of visceral artery aneurysms Signature: Pol J Radiol, 2013; 78(1): 64-68 DOI: 10.12659/PJR.883769 CASE REPORT Received: 2012.09.29 Accepted: 2013.01.15 Time-resolved Magnetic Resonance Angiography for assessment of recanalization

More information

How I do it: Non Contrast-Enhanced MR Angiography (syngo NATIVE)

How I do it: Non Contrast-Enhanced MR Angiography (syngo NATIVE) Clinical How-I-do-it Cardiovascular How I do it: Non Contrast-Enhanced MR Angiography (syngo NATIVE) Manuela Rick, Nina Kaarmann, Peter Weale, Peter Schmitt Siemens Healthcare, Erlangen, Germany Introduction

More information

Renal artery stenosis (RAS) evaluation with Nonenhanced MR Angiography.

Renal artery stenosis (RAS) evaluation with Nonenhanced MR Angiography. Renal artery stenosis (RAS) evaluation with Nonenhanced MR Angiography. Poster No.: C-1329 Congress: ECR 2012 Type: Scientific Exhibit Authors: B. Corcioni, C. Gaudiano, F. Busato, M. G. Orrei, D. Valerio,

More information

Endovascular treatment of intracranial aneurysms with detachable

Endovascular treatment of intracranial aneurysms with detachable ORIGINAL RESEARCH L. Pierot C. Delcourt F. Bouquigny D. Breidt B. Feuillet O. Lanoix S. Gallas Follow-Up of Intracranial Aneurysms Selectively Treated with Coils: Prospective Evaluation of Contrast-Enhanced

More information

Original Research. Tadateru Sumi, DDS, 1 Misa Sumi, DDS, PhD, 1 Marc Van Cauteren, PhD, 2 Yasuo Kimura, DDS, PhD, 1 and Takashi Nakamura, DDS, PhD 1 *

Original Research. Tadateru Sumi, DDS, 1 Misa Sumi, DDS, PhD, 1 Marc Van Cauteren, PhD, 2 Yasuo Kimura, DDS, PhD, 1 and Takashi Nakamura, DDS, PhD 1 * JOURNAL OF MAGNETIC RESONANCE IMAGING 25:1028 1034 (2007) Original Research Parallel Imaging Technique for the External Carotid Artery and its Branches: Comparison of Balanced Turbo Field Echo, Phase Contrast,

More information

Flow Quantification from 2D Phase Contrast MRI in Renal Arteries using Clustering

Flow Quantification from 2D Phase Contrast MRI in Renal Arteries using Clustering Flow Quantification from 2D Phase Contrast MRI in Renal Arteries using Clustering Frank G. Zöllner 1,2, Jan Ankar Monnsen 1, Arvid Lundervold 2, Jarle Rørvik 1 1 Department for Radiology, University of

More information

Non-contrast-enhanced MR portography and hepatic venography with time-spatial labeling inversion pulses: comparison at 1.5 Tesla and 3 Tesla

Non-contrast-enhanced MR portography and hepatic venography with time-spatial labeling inversion pulses: comparison at 1.5 Tesla and 3 Tesla Research Non-contrast-enhanced MR portography and hepatic venography with time-spatial labeling inversion pulses: comparison at 1.5 Tesla and 3 Tesla Acta Radiologica Open 4(5) 1 8! The Foundation Acta

More information

Raja Muthupillai, PhD. Department of Diagnostic and Interventional Radiology St. Luke s Episcopal Hospital. Research Support: Philips Healthcare

Raja Muthupillai, PhD. Department of Diagnostic and Interventional Radiology St. Luke s Episcopal Hospital. Research Support: Philips Healthcare 3D Cardiac Imaging Raja Muthupillai, PhD Department of Diagnostic and Interventional Radiology St. Luke s Episcopal Hospital Houston, TX Disclosures Research Support: Philips Healthcare This presentation

More information

Assessment of Coronary Arteries with Total Study Time of Less than 30 Minutes by Using Whole-Heart Coronary MR Angiography

Assessment of Coronary Arteries with Total Study Time of Less than 30 Minutes by Using Whole-Heart Coronary MR Angiography Hajime Sakuma, MD Yasutaka Ichikawa, MD Naohisa Suzawa, MD Tadanori Hirano, MD Katsutoshi Makino, MD Nozomu Koyama, RT Marc Van Cauteren, PhD Kan Takeda, MD Published online before print 10.1148/radiol.2371040830

More information

Methods. Yahya Paksoy, Bülent Oğuz Genç, and Emine Genç. AJNR Am J Neuroradiol 24: , August 2003

Methods. Yahya Paksoy, Bülent Oğuz Genç, and Emine Genç. AJNR Am J Neuroradiol 24: , August 2003 AJNR Am J Neuroradiol 24:1364 1368, August 2003 Retrograde Flow in the Left Inferior Petrosal Sinus and Blood Steal of the Cavernous Sinus Associated with Central Vein Stenosis: MR Angiographic Findings

More information

Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR: Comparison with Fast Spin-Echo MR in Diseases of the Brain

Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR: Comparison with Fast Spin-Echo MR in Diseases of the Brain Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR: Comparison with Fast Spin-Echo MR in Diseases of the Brain Mahesh R. Patel, Roman A. Klufas, Ronald A. Alberico, and Robert R. Edelman PURPOSE:

More information

Fibromuscular Dysplasia (FMD) of the renal arteries Angiographic features and therapeutic options

Fibromuscular Dysplasia (FMD) of the renal arteries Angiographic features and therapeutic options Fibromuscular Dysplasia (FMD) of the renal arteries Angiographic features and therapeutic options Poster No.: C-0630 Congress: ECR 2012 Type: Educational Exhibit Authors: K. I. Ringe, B. Meyer, F. Wacker,

More information

High-Resolution MR Angiography: Results in Diseased Arteries

High-Resolution MR Angiography: Results in Diseased Arteries IAGS Proceedings NEW IMAGING FOR NEW AND OLD DISEASES High-Resolution MR Angiography: Results in Diseased Arteries Peter Gonschior, M D, Ingo Pragst, M D, Gregor Valassis, M D, Claudia Vo g e l - Wiens,

More information

Perforating arteries originating from the posterior communicating artery: a 7.0-Tesla MRI study

Perforating arteries originating from the posterior communicating artery: a 7.0-Tesla MRI study Eur Radiol (2009) 19: 2986 2992 DOI 10.1007/s00330-009-1485-4 MAGNETIC RESONANCE Mandy M. A. Conijn Jeroen Hendrikse Jaco J. M. Zwanenburg Taro Takahara Mirjam I. Geerlings Willem P. Th. M. Mali Peter

More information

Renal vascular evaluation with 64 Multislice Computerized Tomography Daniela Stoisa, Fabrizzio E. Galiano, Andrés Quaranta, Roberto L.

Renal vascular evaluation with 64 Multislice Computerized Tomography Daniela Stoisa, Fabrizzio E. Galiano, Andrés Quaranta, Roberto L. Renal vascular evaluation with 64 Multislice Computerized Tomography Daniela Stoisa, Fabrizzio E. Galiano, Andrés Quaranta, Roberto L. Villavicencio Footnote Diagnóstico Médico Oroño. Bv. Oroño 1515. 2000.

More information

CT angiography techniques. Boot camp

CT angiography techniques. Boot camp CT angiography techniques Boot camp Overview Basic concepts Contrast administration arterial opacification Time scan acquisition during the arterial phase Protocol examples Helical non-gated CTA Pulmonary

More information

Non-Contrast MRA. How and When 1996! Why Non-Contrast MRA? Angiography: What are our goals? Inflow Techniques Differences in excitation hx

Non-Contrast MRA. How and When 1996! Why Non-Contrast MRA? Angiography: What are our goals? Inflow Techniques Differences in excitation hx A major teaching hospital of Harvard Medical School Angiography: What are our goals? Non-Contrast MRA: How and When Neil M. Rofsky, M.D. Professor of Radiology, Harvard Medical School Director of MRI &

More information

CLINICAL PRESENTATION AND RADIOLOGY QUIZ QUESTION

CLINICAL PRESENTATION AND RADIOLOGY QUIZ QUESTION Donald L. Renfrew, MD Radiology Associates of the Fox Valley, 333 N. Commercial Street, Suite 100, Neenah, WI 54956 6/23/2012 Radiology Quiz of the Week # 78 Page 1 CLINICAL PRESENTATION AND RADIOLOGY

More information

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography 16-MDCT Coronary Angiography Shim et al. 16-MDCT Coronary Angiography Sung Shine Shim 1 Yookyung Kim Soo Mee Lim Received December 1, 2003; accepted after revision June 1, 2004. 1 All authors: Department

More information

Inhance (Inflow Inversion Recovery) Non-contrast Renal MRA in the assessment of renal artery disease.

Inhance (Inflow Inversion Recovery) Non-contrast Renal MRA in the assessment of renal artery disease. Inhance (Inflow Inversion Recovery) Non-contrast Renal MRA in the assessment of renal artery disease. Poster No.: C-1304 Congress: ECR 2013 Type: Scientific Exhibit Authors: A. D. Sotomayor 1, M. C. Sebastia

More information

Evaluation of Intracranial Vasculatures in Healthy Subjects with Arterial-Spin-Labeling-Based 4D-MR Angiography at 3T

Evaluation of Intracranial Vasculatures in Healthy Subjects with Arterial-Spin-Labeling-Based 4D-MR Angiography at 3T Magn Reson Med Sci, Vol. 15, No. 3, pp. 335 339, 2016 doi:10.2463/mrms.tn.2015-0081 TECHNICAL NOTE Evaluation of Intracranial Vasculatures in Healthy Subjects with Arterial-Spin-Labeling-Based 4D-MR Angiography

More information

MR coronary artery imaging with 3D motion adapted gating (MAG) in comparison to a standard prospective navigator technique

MR coronary artery imaging with 3D motion adapted gating (MAG) in comparison to a standard prospective navigator technique Journal of Cardiovascular Magnetic Resonance (2005) 7, 793 797 Copyright D 2005 Taylor & Francis Inc. ISSN: 1097-6647 print / 1532-429X online DOI: 10.1080/10976640500287547 ANGIOGRAPHY MR coronary artery

More information

Real-time Projection MR Angiography: Feasibility Study 1

Real-time Projection MR Angiography: Feasibility Study 1 Jean-Michel Serfaty, MD Ergin Atalar, PhD Jerome Declerck, PhD Perry Karmakar, MS Harald H. Quick, MS Kendrick A. Shunk, MD Alan W. Heldman, MD Xiaoming Yang, MD, PhD Index terms: Angiography, contrast

More information

Dynamic 3D MR Angiography of Intra- and Extracranial Vascular Malformations at 3T: A Technical Note

Dynamic 3D MR Angiography of Intra- and Extracranial Vascular Malformations at 3T: A Technical Note AJNR Am J Neuroradiol 26:630 634, March 2005 Technical Note Dynamic 3D MR Angiography of Intra- and Extracranial Vascular Malformations at 3T: A Technical Note S. Ziyeh, R. Strecker, A. Berlis, J. Weber,

More information

Clinical Applications

Clinical Applications C H A P T E R 16 Clinical Applications In selecting pulse sequences and measurement parameters for a specific application, MRI allows the user tremendous flexibility to produce variations in contrast between

More information

A free-breathing non-contrast-enhanced pulmonary magnetic resonance angiography at 3 Tesla

A free-breathing non-contrast-enhanced pulmonary magnetic resonance angiography at 3 Tesla Chinese Medical Journal 2009;122(18):2111-2116 2111 Original article A free-breathing non-contrast-enhanced pulmonary magnetic resonance angiography at 3 Tesla YANG Jian, WANG Wei, WANG Ya-rong, NIU Gang,

More information

The Low Sensitivity of Fluid-Attenuated Inversion-Recovery MR in the Detection of Multiple Sclerosis of the Spinal Cord

The Low Sensitivity of Fluid-Attenuated Inversion-Recovery MR in the Detection of Multiple Sclerosis of the Spinal Cord The Low Sensitivity of Fluid-Attenuated Inversion-Recovery MR in the Detection of Multiple Sclerosis of the Spinal Cord Mark D. Keiper, Robert I. Grossman, John C. Brunson, and Mitchell D. Schnall PURPOSE:

More information

MRI Abdomen Protocol Pancreas/MRCP with Contrast

MRI Abdomen Protocol Pancreas/MRCP with Contrast MRI Abdomen Protocol Pancreas/MRCP with Contrast Reviewed By: Brett Mollard, MD; Anna Ellermeier, MD Last Reviewed: July 2018 Contact: (866) 761-4200 Standard uses: 1. Characterization of cystic and solid

More information

Functional Chest MRI in Children Hyun Woo Goo

Functional Chest MRI in Children Hyun Woo Goo Functional Chest MRI in Children Hyun Woo Goo Department of Radiology and Research Institute of Radiology Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea No ionizing radiation

More information

Recognition of individuals with possible renal artery stenosis (RAS) is widely considered an important clinical application of contrast material enhan

Recognition of individuals with possible renal artery stenosis (RAS) is widely considered an important clinical application of contrast material enhan Note: This copy is for your personal non-commercial use only. To order presentation-ready copies for distribution to your colleagues or clients, contact us at www.rsna.org/rsnarights. Gilles Soulez, MD,

More information

Non-Invasive Follow-up Evaluation of Post-Embolized AVM with Time-Resolved MRA: A Case Report

Non-Invasive Follow-up Evaluation of Post-Embolized AVM with Time-Resolved MRA: A Case Report Non-Invasive Follow-up Evaluation of Post-Embolized AVM with Time-Resolved MRA: A Case Report Yong Woon Shim, MD 1 Tae-Sub Chung, MD 1 Won-Suk Kang, MD 1 Jin-Yang Joo, MD 2 Ralph Strecker, MD 3 Juergen

More information

B-Flow, Power Doppler and Color Doppler Ultrasound in the Assessment of Carotid Stenosis: Comparison with 64-MD-CT Angiography

B-Flow, Power Doppler and Color Doppler Ultrasound in the Assessment of Carotid Stenosis: Comparison with 64-MD-CT Angiography Med. J. Cairo Univ., Vol. 85, No. 2, March: 805-809, 2017 www.medicaljournalofcairouniversity.net B-Flow, Power Doppler and Color Doppler Ultrasound in the Assessment of Carotid Stenosis: Comparison with

More information

Index words : Bile duct radiography, technology Bile ducts MR Bile ducts surgery Liver, transplantation

Index words : Bile duct radiography, technology Bile ducts MR Bile ducts surgery Liver, transplantation Hilar Branching Anatomy of Living Adult Liver Donors: Comparison of T2-MR Cholangiography and Contrast Enhanced T1-MR Cholangiography in Terms of Diagnostic Utility 1 Joon Seok Lim, M.D. 1, Myeong-Jin

More information

MRA Evaluation of Intravascular Stents

MRA Evaluation of Intravascular Stents MR Evaluation of Intravascular Stents MR can be successfully utilized in evaluating intravascular stents, particularly in the case of newer nonferromagnetic stents. Y KEVIN W. MENNITT, MD, ND JOHN H. RUNDCK,

More information

The ejournal of the European Society of Minimally Invasive Neurological Therapy

The ejournal of the European Society of Minimally Invasive Neurological Therapy The ejournal of the European Society of Minimally Invasive Neurological Therapy Diagnostic performance of contrast enhanced magnetic resonance presenting with subarachnoid haemorrhage Willem van Zwam,

More information

MRA of the hand at 3 Tesla: Technical considerations and spectrum of findings

MRA of the hand at 3 Tesla: Technical considerations and spectrum of findings MRA of the hand at 3 Tesla: Technical considerations and spectrum of findings Poster No.: C-837 Congress: ECR 2009 Type: Educational Exhibit Topic: Chest - Vascular Authors: T. M. Carr III, A. P. Crane,

More information

Postoperative Assessment of Extracranial Intracranial Bypass by Time- Resolved 3D Contrast-Enhanced MR Angiography Using Parallel Imaging

Postoperative Assessment of Extracranial Intracranial Bypass by Time- Resolved 3D Contrast-Enhanced MR Angiography Using Parallel Imaging AJNR Am J Neuroradiol 26:2243 2247, October 2005 Postoperative Assessment of Extracranial Intracranial Bypass by Time- Resolved 3D Contrast-Enhanced MR Angiography Using Parallel Imaging Kazuhiro Tsuchiya,

More information

Fulfilling the Promise

Fulfilling the Promise Fulfilling the Promise of Cardiac MR Non-contrast, free-breathing technique generates comprehensive evaluation of the coronary arteries By Maggie Fung, MR Cardiovascular Clinical Development Manager; Wei

More information

Evaluation of Carotid Vessels and Vertebral Artery in Stroke Patients with Color Doppler Ultrasound and MR Angiography

Evaluation of Carotid Vessels and Vertebral Artery in Stroke Patients with Color Doppler Ultrasound and MR Angiography Evaluation of Carotid Vessels and Vertebral Artery in Stroke Patients with Color Doppler Ultrasound and MR Angiography Dr. Pramod Shaha 1, Dr. Vinay Raj R 2, Dr. (Brig) K. Sahoo 3 Abstract: Aim & Objectives:

More information

Three-Dimensional Dynamic Subtraction Contrast Enhanced Magnetic Resonance Angiography of the Peripheral Arteries An Initial Experience

Three-Dimensional Dynamic Subtraction Contrast Enhanced Magnetic Resonance Angiography of the Peripheral Arteries An Initial Experience ORIGINAL ARTICLE Three-Dimensional Dynamic Subtraction Contrast Enhanced Magnetic Resonance Angiography of the Peripheral Arteries An Initial Experience C K Ho, M. Med (Radiology), Department of Imaging,

More information

Liver imaging takes a step forward with Ingenia

Liver imaging takes a step forward with Ingenia Publication for the Philips MRI Community ISSUE 49 2013 / 2 Liver imaging takes a step forward with Ingenia Lyon South Hospital strives to move from several studies first CT, then MR or PET to using just

More information

Extracranial Carotid Arteries: Evaluation with Black Blood MR Angiography

Extracranial Carotid Arteries: Evaluation with Black Blood MR Angiography Robert R. Edelman, MD #{149} Heinrich P. Mattle, MD #{149} Bernd Wallner, MD #{149} Richard Bajakian, MD #{149} Jonathan Kleefield, MD #{149} Craig Kent, MD #{149} John J. Skillman, MD Jeffrey B. Mendel,

More information

Original Article Cardiovascular Imaging

Original Article Cardiovascular Imaging Original Article Cardiovascular Imaging http://dx.doi.org/10.3348/kjr.2016.17.1.69 pissn 1229-6929 eissn 2005-8330 Korean J Radiol 2016;17(1):69-78 Optimal Blood Suppression Inversion Time Based on Breathing

More information

Coronary angiography is the standard way of visualizing

Coronary angiography is the standard way of visualizing Clinical Investigation and Reports Coronary Artery Fly-Through Using Electron Beam Computed Tomography Peter M.A. van Ooijen, MSc; Matthijs Oudkerk, MD, PhD; Robert J.M. van Geuns, MD; Benno J. Rensing,

More information

Magnetic Resonance Imaging. Basics of MRI in practice. Generation of MR signal. Generation of MR signal. Spin echo imaging. Generation of MR signal

Magnetic Resonance Imaging. Basics of MRI in practice. Generation of MR signal. Generation of MR signal. Spin echo imaging. Generation of MR signal Magnetic Resonance Imaging Protons aligned with B0 magnetic filed Longitudinal magnetization - T1 relaxation Transverse magnetization - T2 relaxation Signal measured in the transverse plane Basics of MRI

More information

Cervical Spine: Three-dimensional Fast Spin-Echo MR Imaging Improved Recovery of Longitudinal Magnetization with Driven Equilibrium Pulse 1

Cervical Spine: Three-dimensional Fast Spin-Echo MR Imaging Improved Recovery of Longitudinal Magnetization with Driven Equilibrium Pulse 1 Elias R. Melhem, MD Ryuta Itoh, MD, PhD Paul J. M. Folkers, PhD Index terms: Magnetic resonance (MR), technology, 34.121419 Spinal cord, MR, 341.121419 Spine, MR, 34.121419 Radiology 2001; 218:283 288

More information

Multislice CTA for Renal Artery Stenting

Multislice CTA for Renal Artery Stenting Multislice CT for Renal rtery Stenting How CT can be a useful modality for diagnosing and managing renal artery stenosis for stent placement. Y MICHEL WHOLEY, MD, M; JMES WU, ; WILLIM C.L. WU, MD, FCC;

More information

MR Imaging with the CCSVI or Haacke protocol

MR Imaging with the CCSVI or Haacke protocol MR Imaging with the CCSVI or Haacke protocol Reports from the Haacke protocol are often made available to the patients. The report consists of four major components: 1. anatomical images of major neck

More information

3D time-of-flight (3D TOF) MR angiography (MRA)

3D time-of-flight (3D TOF) MR angiography (MRA) ORIGINAL RESEARCH H.A. Deutschmann M. Augustin J. Simbrunner B. Unger H. Schoellnast G.A. Fritz G.E. Klein Diagnostic Accuracy of 3D Time-of-Flight MR Angiography Compared with Digital Subtraction Angiography

More information

Time-Of-Flight MRA. Faculty Disclosures Vincent B. Ho, M.D. Presentation Objectives. MRA Techniques. Pros and Cons of MRA

Time-Of-Flight MRA. Faculty Disclosures Vincent B. Ho, M.D. Presentation Objectives. MRA Techniques. Pros and Cons of MRA Faculty Disclosures Vincent B. Ho, M.D. MR Angiography Techniques and Pitfalls Financial Disclosure Grant/Research Support General Electric Medical Systems Off-Label/Investigational Drug Use Dr. Ho will

More information

Cerebral MR Venography: Normal Anatomy and Potential Diagnostic Pitfalls

Cerebral MR Venography: Normal Anatomy and Potential Diagnostic Pitfalls AJNR Am J Neuroradiol 21:74 78, January 2000 Cerebral MR Venography: Normal Anatomy and Potential Diagnostic Pitfalls R. H. Ayanzen, C. R. Bird, P. J. Keller, F. J. McCully, M. R. Theobald, and J. E. Heiserman

More information

History and Science of CO 2 Digital Subtraction Angiography

History and Science of CO 2 Digital Subtraction Angiography History and Science of CO 2 Digital Subtraction Angiography Kyung Cho, M.D. University of Michigan The First Use of CO 2 as a Nonvascular Contrast Agent 1920s Carelli and Sordelli of Buenos Aires performed

More information

Imaging for Peripheral Vascular Disease

Imaging for Peripheral Vascular Disease Imaging for Peripheral Vascular Disease James G. Jollis, MD Director, Rex Hospital Cardiovascular Imaging Imaging for Peripheral Vascular Disease 54 year old male with exertional calf pain in his right

More information

Robert R. Edelman, 1 * John J. Sheehan, 1 Eugene Dunkle, 1 Nancy Schindler, 2 James Carr, 3 and Ioannis Koktzoglou 1

Robert R. Edelman, 1 * John J. Sheehan, 1 Eugene Dunkle, 1 Nancy Schindler, 2 James Carr, 3 and Ioannis Koktzoglou 1 Magnetic Resonance in Medicine 63:951 958 (2010) Quiescent-Interval Single-Shot Unenhanced Magnetic Resonance Angiography of Peripheral Vascular Disease: Technical Considerations and Clinical Feasibility

More information

Duplex ultrasound is first-line imaging for all

Duplex ultrasound is first-line imaging for all Our Protocol for Transabdominal Pelvic Vein Duplex Ultrasound A summary of s protocol for pelvic vein duplex ultrasonography, including equipment, patient positioning, ultrasound settings, and technique.

More information

Guide to Small Animal Vascular Imaging using the Vevo 770 Micro-Ultrasound System

Guide to Small Animal Vascular Imaging using the Vevo 770 Micro-Ultrasound System Guide to Small Animal Vascular Imaging using the Vevo 770 Micro-Ultrasound System January 2007 Objectives: After completion of this module, the participant will be able to accomplish the following: Understand

More information

Renal Artery Stenosis With Severe Hypertension: A Case Report

Renal Artery Stenosis With Severe Hypertension: A Case Report CASE REPORT Renal Artery Stenosis With Severe Hypertension: A Case Report Suwaid MA ABSTRACT Background: Renal artery stenosis (RAS) is found in 77% of hypertensive patients and is responsible for 1-2%

More information

Carotid MR angiography with traditional bolus timing: clinical observations and Fourier-based modelling of contrast kinetics

Carotid MR angiography with traditional bolus timing: clinical observations and Fourier-based modelling of contrast kinetics Eur Radiol (2009) 19: 2654 2662 DOI 10.1007/s00330-009-1448-9 MAGNETIC RESONANCE Jan Menke Carotid MR angiography with traditional bolus timing: clinical observations and Fourier-based modelling of contrast

More information

Neuroradiology MR Protocols

Neuroradiology MR Protocols Neuroradiology MR Protocols Brain protocols N 1: Brain MRI without contrast N 2: Pre- and post-contrast brain MRI N 3 is deleted N 4: Brain MRI without or pre-/post-contrast (seizure protocol) N 5: Pre-

More information

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved. Interventional Radiology Coding Case Studies Prepared by Stacie L. Buck, RHIA, CCS-P, RCC, CIRCC, AAPC Fellow President & Senior Consultant Week of November 19, 2018 Abdominal Aortogram, Bilateral Runoff

More information

Venous compression to reduce peripheral venous contamination in gadofosveset-enhanced first-pass wholebody

Venous compression to reduce peripheral venous contamination in gadofosveset-enhanced first-pass wholebody Venous compression to reduce peripheral venous contamination in gadofosveset-enhanced first-pass wholebody MRA Poster No.: C-3421 Congress: ECR 2010 Type: Scientific Exhibit Topic: Vascular Authors: Y.

More information

MR Angiography for Abdominal and Thoracic Aortic Aneurysms: Assessment Before Endovascular Repair in Patients with Impaired Renal Function

MR Angiography for Abdominal and Thoracic Aortic Aneurysms: Assessment Before Endovascular Repair in Patients with Impaired Renal Function Atar et al. Angiographi c Measuremen ts of Aneurysms Vascular Imaging Clinical Observations A C M E D E N T U R I C A L I M A G I N G AJR 2006; 186:386 393 0361 803X/06/1862 386 American Roentgen Ray Society

More information

Spontaneous Recanalization after Complete Occlusion of the Common Carotid Artery with Subsequent Embolic Ischemic Stroke

Spontaneous Recanalization after Complete Occlusion of the Common Carotid Artery with Subsequent Embolic Ischemic Stroke Original Contribution Spontaneous Recanalization after Complete Occlusion of the Common Carotid Artery with Subsequent Embolic Ischemic Stroke Abstract Introduction: Acute carotid artery occlusion carries

More information

Guidelines, Policies and Statements D5 Statement on Abdominal Scanning

Guidelines, Policies and Statements D5 Statement on Abdominal Scanning Guidelines, Policies and Statements D5 Statement on Abdominal Scanning Disclaimer and Copyright The ASUM Standards of Practice Board have made every effort to ensure that this Guideline/Policy/Statement

More information

Abdominal applications of DWI

Abdominal applications of DWI Postgraduate course, SPR San Antonio (Texas), May 14-15, 2013 Abdominal applications of DWI Rutger A.J. Nievelstein Wilhelmina Children s s Hospital, Utrecht (NL) Outline What is DWI? How to perform? Challenges

More information

Field Strength. Regional Perfusion Imaging (RPI) matches cerebral arteries to flow territories

Field Strength. Regional Perfusion Imaging (RPI) matches cerebral arteries to flow territories Field Strength Changing how the world looks at MR. Regional Perfusion Imaging (RPI) matches cerebral arteries to flow territories Research groups in Utrecht, Baltimore and Singapore collaborate on this

More information

What Do We Know? Disclosure Statement: 3/11/2015. Deep abdominal imaging

What Do We Know? Disclosure Statement: 3/11/2015. Deep abdominal imaging Marsha M. Neumyer, BS, RVT, FSVU, FSDMS, FAIUM International Director Vascular Diagnostic Educational Services Vascular Resource Associates Harrisburg, PA Disclosure Statement: CME Calendar QR Code Marsha

More information

Duplex Doppler Sonography of the Carotid Artery: False-Positive Results in an Artery Contralateral to an Artery with Marked Stenosis

Duplex Doppler Sonography of the Carotid Artery: False-Positive Results in an Artery Contralateral to an Artery with Marked Stenosis 049 Duplex Doppler Sonography of the Carotid Artery: False-Positive Results in an Artery Contralateral to an Artery with Marked Stenosis William W. Beckett, Jr. Patricia C. Davis James C. Hoffman, Jr.

More information

Vascular Imaging Original Research

Vascular Imaging Original Research MDCT Angiography of Renal Arteries Vascular Imaging Original Research Adam D. Talenfeld 1 Ryan B. Schwope Huntley J. Alper Emil I. Cohen Robert A. Lookstein Talenfeld AD, Schwope RB, Alper HJ, Cohen EI,

More information

AJNR Am J Neuroradiol 26: , June/July 2005

AJNR Am J Neuroradiol 26: , June/July 2005 AJNR Am J Neuroradiol 26:1525 1531, June/July 2005 Three-Dimensional Dynamic MR Digital Subtraction Angiography Using Sensitivity Encoding for the Evaluation of Intracranial Arteriovenous Malformations:

More information

Duplex Ultrasound of the Renal Arteries. Duplex Ultrasound. In the Beginning

Duplex Ultrasound of the Renal Arteries. Duplex Ultrasound. In the Beginning Duplex Ultrasound of the Renal Arteries DIMENSIONS IN HEART AND VASCULAR CARE 2013 PENN STATE HEART AND VASCULAR INSTITUTE ROBERT G. ATNIP MD PROFESSOR OF SURGERY AND RADIOLOGY Duplex Ultrasound Developed

More information

Usefulness of the Navigator-echo triggering Technique for Free-Breathing 3D MRCP

Usefulness of the Navigator-echo triggering Technique for Free-Breathing 3D MRCP Usefulness of the Navigator-echo triggering Technique for Free-Breathing 3D MRCP Poster No.: C-1257 Congress: ECR 2012 Type: Scientific Exhibit Authors: K. Matsunaga, G. Ogasawara, K. Fujii, T. Irie, T.

More information

The Many Views of PAD: Imaging Modalities for the Interventionist

The Many Views of PAD: Imaging Modalities for the Interventionist The Many Views of PAD: Imaging Modalities for the Interventionist Timothy E. Yates, MD Interventional Vascular & Oncological Radiology Mount Sinai Medical Center 5 December 2015 None Disclosures Objectives

More information

KNEE ALIGNMENT SYSTEM (KAS) MRI Protocol

KNEE ALIGNMENT SYSTEM (KAS) MRI Protocol KNEE ALIGNMENT SYSTEM (KAS) MRI Protocol Sample referral sticker Referral Sticker Insert here Corin 17 Bridge Street Pymble NSW Australia 2073 P: +61 (0)2 9497 7400 F: +61 (0)2 9497 7498 E: KAS.customerservice@coringroup.com

More information

Speed, Comfort and Quality with NeuroDrive

Speed, Comfort and Quality with NeuroDrive Speed, Comfort and Quality with NeuroDrive Echelon Oval provides a broad range of capabilities supporting fast, accurate diagnosis of brain conditions and injuries. From anatomical depiction to vascular

More information

The Use and Pitfalls of Intracranial Vessel Wall Imaging: How We Do It 1

The Use and Pitfalls of Intracranial Vessel Wall Imaging: How We Do It 1 This copy is for personal use only. To order printed copies, contact reprints@rsna.org Reviews and Commentary n How I Do It Arjen Lindenholz, MD Anja G. van der Kolk, MD, PhD Jaco J. M. Zwanenburg, PhD

More information

Pre-and Post Procedure Non-Invasive Evaluation of the Patient with Carotid Disease

Pre-and Post Procedure Non-Invasive Evaluation of the Patient with Carotid Disease Pre-and Post Procedure Non-Invasive Evaluation of the Patient with Carotid Disease Michael R. Jaff, D.O., F.A.C.P., F.A.C.C. Assistant Professor of Medicine Harvard Medical School Director, Vascular Medicine

More information

ASL BASICS II. Learning Objectives. Outline. Acquisition. M. A. Fernández-Seara, Ph. D. Arterial spin labeled perfusion MRI: basic theory

ASL BASICS II. Learning Objectives. Outline. Acquisition. M. A. Fernández-Seara, Ph. D. Arterial spin labeled perfusion MRI: basic theory Acquisition ASL BASICS II M. A. Fernández-Seara, Ph. D. Neuroimaging Laboratory Center for Applied Medical Research University of Navarra Pamplona, Spain Outline Arterial spin labeled perfusion MRI: basic

More information

非對比劑與對比劑增強 MRA. 血管攝影與對比劑 A Course of MRI. 本週課程內容 -MR Angiography (MRA) Unenhanced MRA

非對比劑與對比劑增強 MRA. 血管攝影與對比劑 A Course of MRI. 本週課程內容 -MR Angiography (MRA) Unenhanced MRA 本週課程內容 -MR Angiography (MRA) 血管攝影與對比劑 A Course of MRI 盧家鋒助理教授國立陽明大學物理治療暨輔助科技學系 alvin4016@ym.edu.tw 非對比劑增強 MRA(Unenhanced MRA) Time-of-flight (TOF) angiography Phase-contrast (PC) angiography 對比劑增強 MRA(Contrast-enhanced

More information

Subclavian steal syndrome: an underdiagnosed disease

Subclavian steal syndrome: an underdiagnosed disease Subclavian steal syndrome: an underdiagnosed disease Poster No.: C-0753 Congress: ECR 2017 Type: Educational Exhibit Authors: R. O. Martins 1, M. C. Calegari 2, M. Lopes 3, L. Santos 3, L. Cruz 3, R. Vasconcelos

More information

Peripheral arterial disease.

Peripheral arterial disease. Peripheral arterial disease. Navarro Cronberg, Carin; Sjöberg, S; Albrechtsson, Ulf; Leander, Peter; Lindh, Mats; Norgren, Lars; Danielsson, Peter; Sonesson, Björn; Larsson, Elna-Marie Published in: Acta

More information

Vascular Imaging in the Pediatric Abdomen. Jonathan Swanson, MD

Vascular Imaging in the Pediatric Abdomen. Jonathan Swanson, MD Vascular Imaging in the Pediatric Abdomen Jonathan Swanson, MD Goals and Objectives To understand the imaging approach, appearance, and clinical manifestations of the common pediatric abdominal vascular

More information

Diagnostic Performance of the Modern Imaging Modalities in Renovascular Disease: An Evaluation

Diagnostic Performance of the Modern Imaging Modalities in Renovascular Disease: An Evaluation DOI: 10.7860/IJARS/2016/18883:2159 Radiology Section Original Article Diagnostic Performance of the Modern Imaging Modalities in Renovascular Disease: An Evaluation Surg Cdr Brijesh K Soni, Surg Cdr SN

More information

Myocardial Viability: Breath-hold 3D MR Imaging of Delayed Hyperenhancement with Variable Sampling in Time 1

Myocardial Viability: Breath-hold 3D MR Imaging of Delayed Hyperenhancement with Variable Sampling in Time 1 Technical Developments Radiology Thomas K. F. Foo, PhD David W. Stanley, BS Ernesto Castillo, MD Carlos E. Rochitte, MD Yi Wang, MD João A. C. Lima, MD David A. Bluemke, MD, PhD Katherine C. Wu, MD Index

More information

CARDIAC MRI. Cardiovascular Disease. Cardiovascular Disease. Cardiovascular Disease. Overview

CARDIAC MRI. Cardiovascular Disease. Cardiovascular Disease. Cardiovascular Disease. Overview CARDIAC MRI Dr Yang Faridah A. Aziz Department of Biomedical Imaging University of Malaya Medical Centre Cardiovascular Disease Diseases of the circulatory system, also called cardiovascular disease (CVD),

More information

Added value of MR myelography using 3D COSMIC sequence in the diagnosis of lumbar canal stenosis: comparison with routine MR imaging

Added value of MR myelography using 3D COSMIC sequence in the diagnosis of lumbar canal stenosis: comparison with routine MR imaging Added value of MR myelography using 3D COSMIC sequence in the diagnosis of lumbar canal stenosis: comparison with routine MR imaging Poster No.: C-1099 Congress: ECR 2012 Type: Authors: Scientific Exhibit

More information