MDCT of Right Ventricular Function: Comparison of Right Ventricular Ejection Fraction Estimation and Equilibrium Radionuclide Ventriculography, Part 1

Size: px
Start display at page:

Download "MDCT of Right Ventricular Function: Comparison of Right Ventricular Ejection Fraction Estimation and Equilibrium Radionuclide Ventriculography, Part 1"

Transcription

1 Right Ventricular MDCT Cardiac Imaging Original Research A C D E M N E U T R Y L I A M C A I G O F I N G Damien Delhaye 1 Martine Remy-Jardin 1 Antoine Teisseire 1 Claude Hossein-Foucher 2 Sylvie Leroy 3 Alain Duhamel 4 Jacques Remy 1 Delhaye D, Remy-Jardin M, Teisseire A, et al. Keywords: cardiopulmonary imaging, CT technique, heart, lung, MDCT DOI: /AJR Received July 11, 2005; accepted after revision October 31, Department of Thoracic Imaging, Hospital Calmette, University Center of Lille, Blvd. Jules Leclerc, Lille, France. Address correspondence to: M. Remy-Jardin (mremy-jardin@chru-lille.fr). 2 Department of Nuclear Medicine, Hospital Roger Salengro, Lille, France. 3 Department of Pulmonology, Hospital Calmette, University Center of Lille, Lille, France. 4 Department of Medical Statistics, Hospital Calmette, University Center of Lille, Lille, France. AJR 2006; 187: X/06/ American Roentgen Ray Society MDCT of Right Ventricular Function: Comparison of Right Ventricular Ejection Fraction Estimation and Equilibrium Radionuclide Ventriculography, Part 1 OBJECTIVE. The aim of this study was to calculate right ventricular ejection fraction by use of ECG-gated MDCT and to compare the results with those of equilibrium radionuclide ventriculography. SUBJECTS AND METHODS. Forty-nine consecutively examined patients (30 men, 19 women; mean age, 59 years) with known or suspected right ventricular dysfunction secondary to bronchopulmonary (n = 30) or pulmonary vascular (n = 19) disease underwent ECG-gated 16-MDCT angiography of the heart (rotation time, 0.42 second; 120 kv; 300 mas; collimation, mm; pitch, 0.2) after CT angiographic examination of the entire thorax according to a standard protocol. Biphasic administration of a 30% contrast agent was systematically performed (phase 1, 90 ml at 3 ml/s; phase 2, 30 ml at 1.5 ml/s); no patient received additional medication. Right ventricular ejection fraction was calculated after two reviewers in consensus determined the reconstruction windows and segmentation of the right ventricular cavity on a series of diastolic and systolic short-axis images. The results were compared with those of equilibrium radionuclide ventriculography. RESULTS. At data acquisition, the mean (± SD) heart rate of the study group was 82 ± beats per minute (BPM) (range, BPM). ECG showed a sinus rhythm in 30 (61%) of the patients and irregular cardiac rhythm in 19 (39%) of the patients. Agreement between the two techniques was estimated by intraclass correlation coefficient (0.77), the method of Bland and Altman (limits of concordance, 14.9 and 13.7), and percentage of variability between two measurements expressed by mean absolute percentage error (12.1%). The estimated effective dose for heart examination was 7.48 msv with CT and 5 msv with scintigraphy. The mean effective dose for the chest and heart CT examinations was msv. CONCLUSION. Right ventricular ejection fraction can be reliably estimated with 16- MDCT in unselected patients. easurements of right ventricular M (RV) volume and function provide important information for the diagnosis, treatment, follow-up, and prognosis of various cardiac and pulmonary diseases [1 7]. Noninvasive techniques such as radionuclide ventriculography, MRI, and echocardiography have been used for the evaluation of RV function, but not without limitations. Among these techniques, the most readily available is echocardiography, but the complex shape of the right ventricle and its position directly beneath the sternum makes assessment of ventricular function difficult no matter which method (2D or 3D) is used [8 10]. On the other hand, MRI has had high accuracy and reproducibility in the evaluation of RV volume in experimental and clinical studies [11 15] and is now considered the reference standard. However, MRI cannot be used in the evaluation of patients with metal implants (e.g., pacemakers and defibrillators) or severe claustrophobia. In addition, long examination times in a supine position and repeated breath-hold periods not only are stressful for patients with congestive heart failure and high-grade dyspnea but also can lead to considerable impairment of image quality. Also, this technique may not be readily available in clinical practice for such indications, limiting its applicability. RV function can be assessed with radionuclide ventriculography by two types of techniques: first pass and equilibrium [16 18]. Both techniques require selection of views of the right ventricle to optimize separation from the surrounding structures, but both techniques have difficulties inherent to gated blood pool imag- AJR:187, December

2 ing, such as border recognition and chamber overlap. Despite these limitations, radionuclide ventriculography appears to be the simplest approach to quantitative assessment of global RV function [19]. MDCT can be used for assessment of RV performance with the addition of retrospective ECG gating and use of dedicated cardiac analysis software. Most attention has been directed at validation of such tools for left ventricular functional analysis [20 23]. The purposes of this study were to assess RV ejection fraction (RVEF) with ECG-gated MDCT and to compare the results with those of equilibrium radionuclide ventriculography in a population of patients with respiratory disorders referred for CT angiography of the chest. Subjects and Methods Population Conducted over the 5-month period from January 2004 to May 2004, this prospective study included 49 consecutively registered patients (30 men, 19 women; mean age, 59 ± 14 years; age range, years) with known or suspected RV dysfunction secondary to bronchopulmonary (n = 30) or pulmonary vascular (n = 19) disease. Underlying bronchopulmonary diseases were chronic obstructive pulmonary disease (n =14), chronic infiltrative lung disease (n = 9), and bronchopulmonary carcinoma managed by chemotherapy with potential cardiac toxicity (n =7). Underlying pulmonary vascular diseases were acute (n =8) or chronic (n = 7) pulmonary embolism and primary pulmonary hypertension (n =4). Before the introduction of MDCT technology, each patient referred for the management of chronic lung disease at our institution underwent unenhanced CT of the thorax. Because MDCT can give additional information about right heart function, inclusion of CT angiography was approved by our institutional review board and ethics committee in the clinical context of known or suspected RV dysfunction. Informed consent from patients was not required. No β-blockers for reducing heart rate were administered before the examination. The mean heart rate of the study population was 82 ± beats per minute (BPM) (range, BPM). The cardiac rhythm was regular in 30 (61%) of the patients and irregular (i.e., presence of a few extrasystolic beats) in 19 (39%) of the patients. CT Acquisition Parameters CT examinations were performed with a 16- MDCT scanner (Sensation 16, Siemens Medical Solutions). The CT protocol consisted of two successive acquisitions, both in the craniocaudal direction, with the patients scanned in the supine position and after deep inspiration. The first acquisition consisted of non ECG-gated CT angiography of the entire thorax and was called the diagnostic scan (scanning parameters: kv; mas; rotation time, 0.5 second; collimation, mm; pitch, 1.5). This examination was systematically performed with online tube current modulation (Care Dose, Siemens Medical Solutions). The second acquisition was focused on the cardiac cavities and consisted of ECG-gated CT angiographic examination of the heart (rotation time, 0.42 second; 120 kv; 300 mas; collimation, mm; pitch, 0.2) and was called the functional scan. Because ECG-controlled dose modulation reduces the milliamperage during the systolic phase, it could theoretically be responsible for degradation of systolic images and thus influence the segmentation process at the level of the right ventricle during systole. Consequently, no dose reduction system monitored with the ECG tracing was used during this acquisition. The interval between the two acquisitions varied between 8 and 10 seconds, including a minimum of 4 seconds between the two helical scans and the time needed to reposition the table for the second acquisition. The patient was allowed to breathe between the two scans. The dose length product was systematically recorded after each acquisition. CT Injection Protocol Biphasic administration of 120 ml of 300 mg I/mL contrast material ([iohexol], Visipaque 300, Amersham Health) was systematically performed. The first phase was aimed at obtaining optimal vascular opacification for the diagnostic scan and consisted of administration of 90 ml at 3 ml/s. The automatic bolus-triggering software program available on the CT unit (Care Bolus, Siemens Medical Solutions) was systematically used. A circular region of interest was positioned at the level of the ascending aorta, and the threshold for triggering data acquisition was preset at 100 H (standard chest CT angiographic protocol in our department). The second phase was aimed at obtaining enhancement of the cardiac cavities compatible with delineation of the ventricular cavities during the functional scan (i.e., without streak artifacts caused by too high a concentration of contrast material within the right cardiac cavities). Images were obtained with administration of 30 ml of contrast material at 1.5 ml/s immediately after administration of the first 90 ml of contrast medium for the diagnostic scan. CT Image Reconstruction The diagnostic scans were reconstructed according to the protocol used in clinical practice. Contiguous 1-mm-thick images were viewed in both mediastinal (window width, 450 H; window center, 80 H; soft reconstruction kernel) and lung parenchymal (window width, 1,600 H; window center, 600 H; high spatial frequency algorithm) window settings. The functional scans were reconstructed as follows. The first step consisted of choosing the temporal window for reconstruction of systolic and diastolic images. To identify the maximal systolic contraction and diastolic relaxation phases, we acquired transverse test images in 5% steps through the entire R R interval at the midventricular level. Enddiastolic and end-systolic phases were identified from the ECG tracing and were controlled visually as the images showing the largest and smallest endocavitary diameters, respectively. The second step consisted of reconstruction of the volume scanned during the functional scan in the diastolic and systolic phases. Two sets of 1-mm-thick axial transverse scans obtained at 0.7-mm intervals were reconstructed with a soft kernel (B30f) on the basis of the temporal window previously chosen. The third step consisted of reconstruction of 3-mm-thick contiguous 2D images of the cardiac cavities along the short axis. Two series of images were then reconstructed: the diastolic and systolic short-axis images, which enabled subsequent calculation of functional parameters (Fig. 1). The first two steps of the retrospective ECG-gated image reconstruction were performed on the scanner workstation (Navigator, Siemens Medical Solutions). The third step of image reconstruction was performed on a commercially available console (Leonardo workstation, Siemens Medical Solutions). To improve the temporal resolution and to avoid motion artifacts, we used a multisegmental image reconstruction algorithm (with raw data from up to two cardiac cycles) (Adaptive Cardio-Volume algorithm, release VA 70, Siemens Medical Solutions) for generating images in each case. CT Parameters Evaluated on Short-Axis Images Image quality of functional scans Two categories of parameters were evaluated, namely, level of enhancement within the RV cavity and presence of artifacts. There were two goals of measurement of the level of enhancement within the RV cavity on medioventricular short-axis images of the right ventricle. The first was analysis of the overall attenuation value within the right ventricle, measured after positioning of a region of interest over almost the entire RV surface (Fig. 2A). The second goal was a search for a gradient of attenuation from top to bottom of the right ventricle potentially created by the injection protocol. The short-axis image of the right ventricle was divided into upper, middle, and lower thirds. The attenuation values were individually measured at these levels after positioning of the region of interest within the central portion of each zone (Fig. 2B). During analysis of the CT scans, the two reviewers noted the presence or ab AJR:187, December 2006

3 Right Ventricular MDCT A C A B D B Fig year-old woman with chronic obstructive pulmonary disease. Reconstruction of short-axis ECGgated CT angiographic images of cardiac cavities. A, Diastolic reconstructed transverse image. B, Multiplanar reconstruction of A in short-axis orientation. C, Systolic reconstructed transverse image. D, Multiplanar reconstruction of C in short-axis orientation. Fig year-old man with bronchopulmonary carcinoma treated by chemotherapy with resulting cardiac toxity. Analysis of level of enhancement of ECGgated CT angiographic images of right ventricular cavity. A, Overall attenuation value within right ventricle was measured after positioning of region of interest (outline) over almost entire right ventricular surface. B, Search for gradient of attenuation from top to bottom of right ventricle was evaluated with measurements obtained in upper, middle, and lower thirds (circles) of right ventricle. sence of image artifacts caused by irregular cardiac rhythm, metal (e.g., presence of a pacemaker), or calcifications. The observers were aware of the presence of extrasystolic beats (arrhythmic ECG gating of the sequence) during the CT examination because this parameter was systematically noted by the examiner on the sequence protocol sheet. Segmentation of RV cavity The segmentation process required delineation of the RV endocardial contours and identification of the RV borders with the pulmonary trunk and right atrium. The endomyocardial contours were manually delineated on short-axis images of the right ventricle at end-diastole and end-systole (Fig. 3). Window settings were adapted for each examination to achieve the best AJR:187, December

4 Fig year-old woman with acute pulmonary embolism. ECG-gated CT angiographic images show segmentation of right ventricular cavity. A D, Endocardial borders of systolic multiplanar reconstruction traced manually. (Fig. 3 continues on next page) A C contrast between myocardium and blood. Papillary muscles, the moderator band, and trabeculations of the right ventricle were included in the lumen. The RV outflow tract was included in the RV volume. Endocardial drawings were rated as precise when RV endocardial contours were easily delineated and as imprecise in cases of difficult delineation. In the latter situation, factors affecting the manual tracing of endocardial contours were systematically noted. The junction between the right ventricle and the pulmonary trunk was recognized by means of visualization of the pulmonic valves or identification of the junction between the ventricular myocardium and the pulmonary trunk. The junction between the right atrium and the right ventricle was based on recognition of the junction between the interatrial and interventricular septa, identification of the atrioventricular valve, and/or identification of the right coronary artery in the atrioventricular septum. Calculation of RVEF RV function was evaluated on the Leonardo console with the manufacturer s software dedicated to analysis of cardiac function (Syngo Argus software, 2003 version; Siemens Medical Solutions). The analysis software calculated RV end-diastolic and end-systolic volumes by summing the volumes of all short-axis slices (Simpson method), RV stroke volume (RV end-diastolic volume minus RV end-systolic volume), and RVEF (RV stroke volume / by RV enddiastolic volume 100%). RVEF results were compared with those of equilibrium radionuclide ventriculography performed within 24 hours. The CT protocol was supervised by two reviewers, each of whom had 1 year of experience in cardiac CT at the time of initiation of this study. The reviewers determined in consensus the two operator-dependent steps, namely the choice of the reconstruction window and delineation of the endocardial contours of the right ventricle. Equilibrium Radionuclide Ventriculography All patients underwent equilibrium radionuclide ventriculography at rest in the supine position. The procedure was performed with red blood cells labeled in vivo with 20 mci of 99m Tc. Data were acquired in 45-degree left anterior and in 30-degree right anterior oblique views with a gamma camera (DST, SMV International). All studies were formatted at 16 frames per cardiac cycle. R R interval and heart rate were recorded. Cardiac cycles with B D R R intervals not within 20% of the average value were discarded. Left ventricular ejection fraction and RVEF were determined with the equilibrium technique by automated detection of end-diastolic and end-systolic contours with manual correction if necessary. All radionuclide angiograms were interpreted by the same experienced investigator, who was not aware of the CT results. Statistical Analysis Statistical analysis was performed with commercially available software (SAS Institute). Statistical significance was set at p < Results were expressed as mean, standard deviation, and interquartile range for continuous variables and as frequencies and percentages for categorical variables. Concordance between MDCT and equilibrium radionuclide ventriculography was assessed with intraclass correlation coefficient (ICC) for continuous variables. The scale used for interpretation of this concordance was that described by Fleiss [24]. A concordance value of was rated moderate and a value > 0.80, good. A Bland-Altman [25] diagram was used for further examination of concordance between the two techniques. Mean absolute percentage 1600 AJR:187, December 2006

5 Right Ventricular MDCT Fig. 3 (continued) 49-year-old woman with acute pulmonary embolism. ECG-gated CT angiographic images show segmentation of right ventricular cavity. E H, Diastolic multiplanar reconstruction traced manually. error (MAPE) also was calculated. The 95% CI for mean difference was an estimate of the limits of concordance between the two methods. MAPE is the absolute value of the difference between the two measurements over the mean of the two measurements expressed as a percentage. The kappa coefficient was used to assess agreement between qualitative variables. The scale used to describe the degree of agreement was that proposed by Landis and Koch [26]. A degree of concordance < 0.20 was rated poor; , fair; , moderate; , good; and , excellent. The primary end point of this study was the ICC between the RVEF values estimated with two examinations. The number of subjects needed was calculated by the method described by Walter et al. [27]. For a minimum acceptable ICC of 0.8, it was estimated that 46 patients were needed for 80% power with significance at 5% for an estimated intraclass correlation of 0.9. Additional statistical analyses were performed as follows. Mean attenuation values in the various regions of the right ventricle were compared by repeated analyses of variance. For continuous parameters, the results of CT and scintigraphy were compared by paired Student s t test or paired E G Wilcoxon s test when the sample size was less than 30. Comparisons between groups were performed with the Mann-Whitney test. Results Image Quality of CT Scans All diagnostic scans were compatible with adequate evaluation of the underlying disorder. Concerning functional scans, all patients were able to hold their breath during data acquisition, and the mean duration of data acquisition was 22 ± 1.18 seconds (range, seconds). The mean attenuation value within the RV cavity was 199 ± H (range, H). No significant difference was found in mean attenuation value measured in the upper ( ± H; range, H), middle ( ± H; range, H) and lower ( ± H; range, H) thirds of the right ventricle (repeated analysis of variance, p = ). Calculation of RVEF with MDCT Segmentation of RV cavity Clear delineation of the endocardial contours was possible in 34 (69%) of the examinations. In all of F H these cases, homogeneous enhancement of the right ventricle without streak artifacts was present around the ventricular cavity (mean attenuation value within right ventricle, ± H; range, H), and no motion artifacts related to irregular cardiac rhythm were present. Imprecise endocardial delineation was found in 15 (31%) of the examinations. The delineation process was rated as imprecise because a low level of enhancement within the right ventricle led to suboptimal delineation of the endocardial contours (n = 11). The mean attenuation value in the right ventricles of these patients was significantly lower than that measured in the group of 34 patients with images graded as having easily delineated endocardial contours ( ± H; range, H) (Mann-Whitney test, p < 0.001). The presence of artifacts was related to extrasystolic beats (n = 4), myocardial or pericardial calcification (n = 2), and/or presence of a pacemaker (n = 1). In these 15 cases, alteration of image quality did not hamper the RV segmentation process. Table 1 summarizes the frequency of identification of the anatomic bor- AJR:187, December

6 TABLE 1: Frequency of Identification of Anatomic Borders of Right Ventricle in 49 Patients Structure Identified No. of Patients (%) Anatomic junction between right ventricle and pulmonary trunk Junction between right ventricular myocardium and pulmonary trunk 43 (88) Pulmonary valves 17 (35) Anatomic junction between the right ventricle and right atrium Junction between interatrial and interventricular septa 46 (94) Tricuspid valve 7 (14) Right coronary artery in atrioventricular septum 23 (47) Fig. 4 Plot of difference between MDCT and equilibrium scintigraphy measurements of right ventricular ejection fraction against their means. Thin line represents mean difference. Solid lines represent 95% CIs for mean difference. Difference Between CT and Scintigraphy 0 0 ders between the right ventricle and the right atrium and between the right ventricle and the pulmonary trunk. Calculation of RV volume and RVEF The mean values of end-diastolic and end-systolic RV volume were ± ml (range, ml) and ± ml (range, ml), respectively. Mean RVEF was 43.63% ± 8.95% (range, 13 61%). The time needed to obtain RVEF measurements was minutes, including 5 minutes for generation of diastolic and systolic short-axis images and 3 5 minutes for segmentation of RV volume at both phases of the cardiac cycle. Comparison of MDCT and Equilibrium Radionuclide Ventriculography Mean RVEF was 43.63% ± 8.95% (range, 13 61%) with CT and 44.20% ± (range, 13 66%) with equilibrium radionuclide ventriculography. No significant difference was found between the mean values obtained with either technique (paired Student s t test, p = 0.57). Concordance between the Mean Difference in Ejection Fraction (%) two methods was moderate (ICC = 0.77). The dispersion of differences in RVEF assessed with MDCT and scintigraphy are illustrated with a Bland-Altman plot in Figure 4. Only three values (6% of the data) were outside the limits. The limit of concordance for MDCT ranged from 14.9 to The percentage of variability between two measurements expressed by MAPE was 12.1%. In a subanalysis, the mean value of RVEF obtained with CT was compared with that obtained with scintigraphy in two subgroups of patients according to the precision of RV cavity segmentation. There was no significant difference between the mean values determined with CT and scintigraphy in evaluation of the 34 patients for whom delineation of the endocardial contours was rated as precise (mean value with CT, 45.26% ± 8.89%; mean value with radionuclide ventriculography, 46.15% ± 12.43%; paired Student s test, p = 0.49) and the 15 patients for whom delineation of the endocardial contours was rated as imprecise (mean value with CT, 39.93% ± 8.21%; mean value with radionuclide ventriculography, 39.8% ± 8.56%; p = 0.83, Wilcoxon s test). The ICC was 0.77 for the 34 examinations with clear delineation of endocardial contours and 0.68 for the other 15 examinations. According to the ventriculoscintigraphic results, 34 patients had a normal RVEF ( 40%) (mean RVEF, 50.06% ± 8.19%; range, 40 66%) and 15 patients had a low RVEF (< 40%) (mean RVEF, 30.93% ± 6.13%; range, 13 38%). Thirty-two of the 34 patients with a normal RVEF on ventriculoscintigraphy had a normal RVEF on CT (mean RVEF, 48.08% ± 4.88%; range, 40 61%). Twelve of the 15 patients with a low RVEF on ventriculoscintigraphy had a low RVEF on CT (mean RVEF, 32.5% ± 6.83%; range, 13 39%). Thus there was a total of 44 (90%) concordant results between the two techniques. Agreement between the two methods was good (κ = 0.75) in a comparison of the subgroups of patients with normal and reduced RVEF. Radiation Dose The mean dose length product of functional scans was ± mgy cm (range, mgy cm). The estimated mean radiation dose of functional scans was 7.27 msv. The mean theoretic dose for ventriculoscintigraphy was 5 msv. The mean dose length product of diagnostic scans was ± mgy cm (range, mgy cm), leading to an estimated radiation dose of 4.37 msv. The mean effective dose for both chest and heart examinations was msv. Discussion In this study, RVEF calculated from retrospectively ECG-gated MDCT images was found accurate in patients with known or suspected RV dysfunction secondary to bronchopulmonary or pulmonary vascular disease. Imaging of underlying disease was technically successful in all 49 patients, and all scans were suitable for calculation of RVEF. Comparing CT with equilibrium radionuclide ventriculography, we observed that estimates of RVEF with CT were similar with scintigraphy for the overall study group and for the two subgroups of patients with normal and reduced RVEF. We also found that the precision of RV cavity segmentation on CT scans did not affect estimation of RVEF. The latter situation was of particular interest owing to the lack of selection of our population and the lack of administration of specific medication before data acquisition AJR:187, December 2006

7 Right Ventricular MDCT These results suggest that this technique can be used in a wide range of patients in routine clinical practice, allowing precise evaluation of RV function in unselected patients, even those with irregular cardiac rhythm. These results open the possibility of including functional imaging in CT examinations of the chest. The findings are clinically relevant owing to the importance of RV function in the treatment and prognosis of variety of clinical problems [28]. We investigated a CT protocol aimed at providing morphologic information on the underlying respiratory disease as well as functional information about the right ventricle during the same imaging session. To our knowledge, this investigation was the first aimed at integrating functional information into a diagnostic scan; previous investigations of RV function with MDCT focused on cardiac examinations [29, 30]. Using 16-MDCT technology, we designed a two-phase protocol. We started with non ECG-gated acquisition over the entire thorax and followed with ECG-gated examination of the cardiac cavities with biphasic administration of contrast medium. Whereas the first phase was similar to a standard CT angiographic examination of the chest, the second phase was designed to allow acquisition of systolic and diastolic short-axis images of the right ventricle with a level of enhancement compatible with precise delineation of the endocardial contours. The time needed to obtain RVEF measurements varied between 11 and 15 minutes, including two time-consuming steps: creation of diastolic and systolic short-axis images of the cardiac cavities followed by RV segmentation in both cardiac phases, which is in the range reported for CT and MR volumetric left ventricular measurements [22]. The introduction of automated tools for generation of short-axis images of the cardiac cavities at various phases of the cardiac cycle is expected to shorten part of the procedure. With regard to the reconstruction parameters selected in our study, we decided to generate 3-mm-thick contiguous short-axis images of the cardiac cavities. This section thickness, thinner than that reported for CT and MR in evaluation of the left ventricle [22], was chosen to enhance sharpness of the RV endocardial contours and to facilitate precise recognition of the valvular borders of the right ventricle, a well-known potential source of error in scintigraphy [16]. Inclusion of the RV trabeculations and RV outflow tract led to overestimation of RV enddiastolic and end-systolic volumes but did not affect the overall estimate of RVEF. Electron beam CT was the first imaging technique to be compared with MRI for assessment of RV volume and global ventricular function, and it had good agreement with a close correlation and acceptable interobserver variability [31]. Lembcke et al. [29] were the first authors to report their experience with 8- and 16-MDCT performed to measure RV dimensions and function. They conducted their study with a population of 25 patients undergoing cardiac surgery. Those authors found that compared with MRI, MDCT was an accurate and reliable noninvasive technique for evaluating RV measurements. In that study, volumetric evaluation was obtained on a stack of 5-mm-thick axial images with exclusion of the papillary muscles and trabeculae of the right ventricle. Despite different acquisition times for MDCT and MRI, the investigators found good agreement between the techniques, leading them to suggest that differences in temporal resolution between the two techniques are less important than systematic and random measurement errors resulting from the geometry of the right ventricle. Similar conclusions were recently been drawn by Koch et al. [30], who investigated assessment of RV function with 16-MDCT by using two software tools to compare CT with MRI in a population of 19 patients. At a gantry rotation time of 420 milliseconds, the temporal resolution achieved with CT in the study varied between 105 and 210 milliseconds, compared with milliseconds for MRI [29]. Advances in MDCT technology, especially the introduction of 64- MDCT scanners, offer further improvement in this concept of integration of structure and function during CT examinations of the chest, which are first-line imaging tools for most patients with respiratory disease. With the latter technology, one can to obtain two sets of information from a single data set, but this capability requires further confirmation. Assessing RV function with CT raises practical questions regarding radiation dose. In the present study, the mean of 7.27 msv for the functional scan was higher than the mean theoretic dose delivered in radionuclide ventriculography, that is, 5 msv [32]. However, CT provides not only functional but also morphologic information at the level of the cardiac cavities. In this preliminary investigation, we did not use dose-modulation software, which can be used efficiently in such examinations. There were several limitations to this study. First, we compared CT not with MRI, the accepted standard for assessment of RV function, but with radionuclide ventriculography, a method with limitations when applied to the right ventricle, especially in patients with abnormal RV shape and size [15]. However, this method has been shown to have adequate accuracy for routine clinical use [16, 18, 33]. Second, we did not evaluate intraindividual or interindividual variability of cardiac function measurements on CT scans. Because the study was aimed at assessing the accuracy of CT versus a reference method, we decided to focus on the consensus reading of CT scans and to compare these results with those of radionuclide ventriculography. This important practical issue is specifically addressed in a separate study [34]. Third, our analysis was based on a study group of 49 patients, a limitation directly linked to the lack of wide availability of equilibrium scintigraphy for RVEF measurement at our institution. Our conclusions need to be validated in a larger population. In conclusion, this study shows the accuracy of RVEF measurements during CT angiographic examination of the chest performed with 16-MDCT equipment in patients with underlying respiratory disease. References 1. Zehender M, Kasper W, Kauder E, et al. Right ventricular infarction as an independent predictor of prognosis after acute inferior myocardial infarction. N Engl J Med 1993; 328: Setaro JF, Souter R, Remetz MS, et al. Long-term outcome in patients with congestive heart failure and intact systolic left ventricular performance. Am J Cardiol 1992; 69: Menzel T, Kramm T, Brukner A, Mohr-Kahaly S, Mayer E, Meyer J. Quantitative assessment of right ventricular volumes in severe chronic thromboembolic pulmonary hypertension using transthoracic three-dimensional echocardiography: changes due to pulmonary thromboendarterectomy. Eur J Echocardiog 2002; 3: Borer JS, Hochreiter CA, Supino PG, et al. Importance of right ventricular performance measurement in selecting asymptomatic patients with mitral regurgitation for valve surgery. Adv Cardiol 2002; 39: Redington AN. Right ventricular function. Cardiol Clin 2002; 20: Julliere Y, Barbier G, Feldmann L, et al. Additional predictive value of both left and right ventricular ejection fractions on long-term survival in idiopathic dilated cardiomyopathy. Eur Heart J 1997; 18: Polak JF, Holman BL, Wynne J, et al. Right ventricular ejection fraction: an indicator of increased AJR:187, December

8 mortality in patients with congestive heart failure associated with coronary artery disease. J Am Coll Cardiol 1983; 2: Levine RA, Gibson TC, Aretz T, et al. Echocardiographic measurements of right ventricular volumes. Circulation 1984; 69: Kaul S, Tei C, Hopkins JM, Shah PM. Assessment of right ventricular function using two-dimensional echocardiography. Am Heart J 1984; 107: Chan KL, Currie P, Seward J, Hagler D, Mair D, Tajik J. Comparison between three Doppler ultrasound methods in the prediction of pulmonary artery pressures. Am J Coll Cardiol 1987; 9: Sechtem U, Pflugfelter PW, Gould RG, Cassidy MM, Higgins CB. Measurement of right and left ventricular volumes in healthy individuals with cine MR imaging. Radiology 1987; 163: Helbing WA, Bosch HG, Malipaart C, et al. Comparison of echocardiographic methods with magnetic resonance imaging for assessment of right ventricular function in children. Am J Cardiol 1995; 76: Pattynama PM, De Roos A, Van der Wall EE, et al. Evaluation of cardiac function with magnetic resonance imaging. Am Heart J 1994; 128: Niwa K, Uchishiba M, Aotsuka H, et al. Measurement of ventricular volumes by cine magnetic resonance imaging in complex congenital heart disease with morphologically abnormal ventricles. Am Heart J 1996; 131: Rominger MB, Bachmann GF, Pabst W, et al. Right ventricular volumes and ejection fraction with fast cine MR imaging in breath-hold technique: applicability, normal values from 52 volunteers and evaluation of 325 adult cardiac patients. J Magn Reson Imaging 1999; 10: FOR YOUR INFORMATION 16. Maddahi J, Berman DS, Matsuoka DT, et al. A new technique for assessing right ventricular ejection fraction using rapid multiple-gated equilibrium cardiac blood pool scintigraphy: description, validation and findings in chronic coronary artery disease. Circulation 1979; 60: Harpen MD, Robinson AE. Radionuclide determination of right and left ventricular mixing. Eur J Nucl Med 1985; 10: Schulman DS. Assessment of the right ventricle with radionuclide techniques. J Nucl Cardiol 1996; 3: Zaret BL, Wackers FJ. Nuclear cardiology. Part 2. N Engl J Med 1993; 329: Juergens KU, Grude M, Fallenberg EM, et al. Using ECG-gated multidetector CT to evaluate global left ventricular myocardial function in patients with coronary artery disease. AJR 2002; 179: Dirksen MS, Bax JJ, de Roos A, et al. Usefulness of dynamic multislice computed tomography of left ventricular function in unstable angina pectoris and comparison with echocardiography. Am J Cardiol 2002; 90: Juergens KW, Grude M, Maintz D, et al. Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: initial experience. Radiology 2004; 230: Hundt W, Siebert K, Wintersperger BJ, et al. Assessment of global left ventricular function: comparison of cardiac multidetector-row computed tomography with angiocardiography. J Comput Asssist Tomogr 2005; 29: Fleiss JL. Design and analysis of clinical experiments. New York, NY: Wiley, 1986: Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: The reader s attention is directed to part 2 accompanying this article, titled MDCT of Right Ventricular Function: Impact of Methodologic Approach in Estimation of Right Ventricular Ejection Fraction, Part 2, which begins on page Landis J, Koch GG. The measurement of observer agreement for categorical data. Biometrics 1977; 33: Walter SD, Eliasziw M, Donner A. Sample size and optimal designs for reliability studies. Stat Med 1998; 17: Oldershaw P. Assessment of right ventricular function and its role in clinical practice. Br Heart J 1992; 68: Lembcke A, Dohmen PM, Dewey M, et al. Multislice computed tomography for preoperative evaluation of right ventricular volumes and function: comparison with magnetic resonance imaging. Ann Thorac Surg 2005; 79: Koch K, Oellig F, Oberholzer K, et al. Assessment of right ventricular function by 16-detector-row CT: comparison with magnetic resonance imaging. Eur Radiol 2005; 15: Elgetti T, Lembcke A, Enzweiler CN, Breitwieser C, Hamm B, Kivelitz DE. Comparison of electron beam computed tomography with magnetic resonance imaging in assessment of right ventricular volumes and function. J Comput Assist Tomogr 2004; 28: Urr IPC, Ell P. Radiation protection and dosimetry in clinical practice. In: Clinical diagnosis and treatment. New York, NY: Churchill Livingstone, 1998: Le Guludec D, Gauthier H, Porcher R, et al. Prognostic value of radionuclide angiography in patients with right ventricular arrhythmias. Circulation 2001; 103: Remy-Jardin M, Delhaye D, Teisseire A, et al. MDCT of right ventricular function: impact of methodological approach in estimation of right ventricular ejection fraction, part 2. AJR 2006; 187: AJR:187, December 2006

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography 16-MDCT Coronary Angiography Shim et al. 16-MDCT Coronary Angiography Sung Shine Shim 1 Yookyung Kim Soo Mee Lim Received December 1, 2003; accepted after revision June 1, 2004. 1 All authors: Department

More information

General Cardiovascular Magnetic Resonance Imaging

General Cardiovascular Magnetic Resonance Imaging 2 General Cardiovascular Magnetic Resonance Imaging 19 Peter G. Danias, Cardiovascular MRI: 150 Multiple-Choice Questions and Answers Humana Press 2008 20 Cardiovascular MRI: 150 Multiple-Choice Questions

More information

Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot

Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot Korean J Thorac Cardiovasc Surg 2017;50:71-77 ISSN: 2233-601X (Print) ISSN: 2093-6516 (Online) CLINICAL RESEARCH https://doi.org/10.5090/kjtcs.2017.50.2.71 Use of Cardiac Computed Tomography for Ventricular

More information

Cardiac Imaging Tests

Cardiac Imaging Tests Cardiac Imaging Tests http://www.medpagetoday.com/upload/2010/11/15/23347.jpg Standard imaging tests include echocardiography, chest x-ray, CT, MRI, and various radionuclide techniques. Standard CT and

More information

Fellows on this rotation are expected to attend nuclear conferences and multimodality imaging conference.

Fellows on this rotation are expected to attend nuclear conferences and multimodality imaging conference. Rotation: Imaging 1 Imaging 1 provides COCATS Level 1 experience for nuclear cardiology (including SPECT and PET) and cardiac CT. Fellows will administer, process, and read cardiac nuclear studies with

More information

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement 3 rd Annual Imaging & Physiology Summit November 20-21, 21, 2009 Seoul, Korea Wm. Guy Weigold, MD, FACC Cardiovascular

More information

Noncoronary Cardiac MDCT

Noncoronary Cardiac MDCT Noncoronary Cardiac MDCT David A. Bluemke, M.D., Ph.D. Professor, of Radiology and Medicine Johns Hopkins University School of Medicine Baltimore, Maryland Toshiba Disclosures Grant support Noncoronary

More information

Cardiac MRI in ACHD What We. ACHD Patients

Cardiac MRI in ACHD What We. ACHD Patients Cardiac MRI in ACHD What We Have Learned to Apply to ACHD Patients Faris Al Mousily, MBChB, FAAC, FACC Consultant, Pediatric Cardiology, KFSH&RC/Jeddah Adjunct Faculty, Division of Pediatric Cardiology

More information

Certificate in Clinician Performed Ultrasound (CCPU) Syllabus. Rapid Cardiac Echo (RCE)

Certificate in Clinician Performed Ultrasound (CCPU) Syllabus. Rapid Cardiac Echo (RCE) Certificate in Clinician Performed Ultrasound (CCPU) Syllabus Rapid Cardiac Echo (RCE) Purpose: Rapid Cardiac Echocardiography (RCE) This unit is designed to cover the theoretical and practical curriculum

More information

Cardiac Computed Tomography

Cardiac Computed Tomography Cardiac Computed Tomography Authored and approved by Koen Nieman Stephan Achenbach Francesca Pugliese Bernard Cosyns Patrizio Lancellotti Anastasia Kitsiou Contents CARDIAC COMPUTED TOMOGRAPHY Page 1.

More information

Aims and objectives. Page 2 of 13

Aims and objectives. Page 2 of 13 Evaluation of right heart function with use of retrospectively ECG- gated 64-slice low dose computed tomography in subjects with and without pulmonary hypertension Poster No.: C-2562 Congress: ECR 2015

More information

Triple Rule-out using 320-row-detector volume MDCT: A comparison of the wide volume and helical modes

Triple Rule-out using 320-row-detector volume MDCT: A comparison of the wide volume and helical modes Triple Rule-out using 320-row-detector volume MDCT: A comparison of the wide volume and helical modes Poster No.: C-0488 Congress: ECR 2012 Type: Authors: Keywords: DOI: Scientific Exhibit E.-J. Kang,

More information

Pulmonary Embolism. Thoracic radiologist Helena Lauri

Pulmonary Embolism. Thoracic radiologist Helena Lauri Pulmonary Embolism Thoracic radiologist Helena Lauri 8.5.2017 Statistics 1-2 out of 1000 adults annually are diagnosed with deep vein thrombosis (DVT) and/or pulmonary embolism (PE) About half of patients

More information

Multiple Gated Acquisition (MUGA) Scanning

Multiple Gated Acquisition (MUGA) Scanning Multiple Gated Acquisition (MUGA) Scanning Dmitry Beyder MPA, CNMT Nuclear Medicine, Radiology Barnes-Jewish Hospital / Washington University St. Louis, MO Disclaimers/Relationships Standard of care research

More information

Recent developments in cardiac CT

Recent developments in cardiac CT REVIEW Recent developments in cardiac CT With the introduction of 64-multidetector row CT, coronary CT angiography has become a clinical tool, owing to improved image quality and reduced breath-hold time,

More information

Perspectives of new imaging techniques for patients with known or suspected coronary artery disease

Perspectives of new imaging techniques for patients with known or suspected coronary artery disease Perspectives of new imaging techniques for patients with known or suspected coronary artery disease Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands Correspondence: Jeroen

More information

Impaired Regional Myocardial Function Detection Using the Standard Inter-Segmental Integration SINE Wave Curve On Magnetic Resonance Imaging

Impaired Regional Myocardial Function Detection Using the Standard Inter-Segmental Integration SINE Wave Curve On Magnetic Resonance Imaging Original Article Impaired Regional Myocardial Function Detection Using the Standard Inter-Segmental Integration Ngam-Maung B, RT email : chaothawee@yahoo.com Busakol Ngam-Maung, RT 1 Lertlak Chaothawee,

More information

Coronary Artery Anomalies from Birth to Adulthood; the Role of CT Coronary Angiography in Sudden Cardiac Death Screening

Coronary Artery Anomalies from Birth to Adulthood; the Role of CT Coronary Angiography in Sudden Cardiac Death Screening Coronary Artery Anomalies from Birth to Adulthood; the Role of CT Coronary Angiography in Sudden Cardiac Death Screening E O Dwyer 1, C O Brien 1, B Loo 1, A Snow Hogan 1, O Buckley1 2, B 1. Department

More information

Gated blood pool ventriculography: Is there still a role in myocardial viability?

Gated blood pool ventriculography: Is there still a role in myocardial viability? Gated blood pool ventriculography: Is there still a role in myocardial viability? Oliver C. Alix, MD Adult Clinical and Nuclear Cardiology St. Luke s Medical Centre - Global City Case Presentation A 62-year-old

More information

Horizon Scanning Technology Summary. Magnetic resonance angiography (MRA) imaging for the detection of coronary artery disease

Horizon Scanning Technology Summary. Magnetic resonance angiography (MRA) imaging for the detection of coronary artery disease Horizon Scanning Technology Summary National Horizon Scanning Centre Magnetic resonance angiography (MRA) imaging for the detection of coronary artery disease April 2007 This technology summary is based

More information

Ischemic heart disease is the leading cause of morbidity and

Ischemic heart disease is the leading cause of morbidity and REVIEW ARTICLE Assessment of Cardiac Function Using Multidetector Row Computed Tomography Sarwar H. Orakzai, MD,* Raza H. Orakzai, MD,* Khurram Nasir, MD, MPH,*Þ and Matthew J. Budoff, MDþ Abstract: In

More information

Pushing the limits of cardiac CT. Steven Dymarkowski Radiology / Medical Imaging Research Centre

Pushing the limits of cardiac CT. Steven Dymarkowski Radiology / Medical Imaging Research Centre Pushing the limits of cardiac CT Steven Dymarkowski Radiology / Medical Imaging Research Centre 5 X 2013 Introduction Rapid technological advances and new clinical applications in cardiovascular imaging

More information

Improving Diagnostic Accuracy of MDCT Coronary Angiography in Patients with Mild Heart Rhythm Irregularities Using ECG Editing

Improving Diagnostic Accuracy of MDCT Coronary Angiography in Patients with Mild Heart Rhythm Irregularities Using ECG Editing Cademartiri et al. Heart Rhythm Irregularities on MDCT Angiography Cardiac Imaging Original Research A C M E D E N T U R I C A L I M A G I N G AJR 2006; 186:634 638 0361 803X/06/1863 634 American Roentgen

More information

Echocardiography as a diagnostic and management tool in medical emergencies

Echocardiography as a diagnostic and management tool in medical emergencies Echocardiography as a diagnostic and management tool in medical emergencies Frank van der Heusen MD Department of Anesthesia and perioperative Care UCSF Medical Center Objective of this presentation Indications

More information

Index of subjects. effect on ventricular tachycardia 30 treatment with 101, 116 boosterpump 80 Brockenbrough phenomenon 55, 125

Index of subjects. effect on ventricular tachycardia 30 treatment with 101, 116 boosterpump 80 Brockenbrough phenomenon 55, 125 145 Index of subjects A accessory pathways 3 amiodarone 4, 5, 6, 23, 30, 97, 102 angina pectoris 4, 24, 1l0, 137, 139, 140 angulation, of cavity 73, 74 aorta aortic flow velocity 2 aortic insufficiency

More information

Left atrial function. Aliakbar Arvandi MD

Left atrial function. Aliakbar Arvandi MD In the clinic Left atrial function Abstract The left atrium (LA) is a left posterior cardiac chamber which is located adjacent to the esophagus. It is separated from the right atrium by the inter-atrial

More information

New Cardiovascular Devices and Interventions: Non-Contrast MRI for TAVR Abhishek Chaturvedi Assistant Professor. Cardiothoracic Radiology

New Cardiovascular Devices and Interventions: Non-Contrast MRI for TAVR Abhishek Chaturvedi Assistant Professor. Cardiothoracic Radiology New Cardiovascular Devices and Interventions: Non-Contrast MRI for TAVR Abhishek Chaturvedi Assistant Professor Cardiothoracic Radiology Disclosure I have no disclosure pertinent to this presentation.

More information

Measurement of Ventricular Volumes and Function: A Comparison of Gated PET and Cardiovascular Magnetic Resonance

Measurement of Ventricular Volumes and Function: A Comparison of Gated PET and Cardiovascular Magnetic Resonance BRIEF COMMUNICATION Measurement of Ventricular Volumes and Function: A Comparison of Gated PET and Cardiovascular Magnetic Resonance Kim Rajappan, MBBS 1,2 ; Lefteris Livieratos, MSc 2 ; Paolo G. Camici,

More information

MR Advance Techniques. Cardiac Imaging. Class IV

MR Advance Techniques. Cardiac Imaging. Class IV MR Advance Techniques Cardiac Imaging Class IV Heart The heart is a muscular organ responsible for pumping blood through the blood vessels by repeated, rhythmic contractions. Layers of the heart Endocardium

More information

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T.

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T. The feasibility of biphasic contrast-media-injection-protocol for chest imaging on 320-slice volume MDCT: Direct comparison of biphasic and bolus contrast-media injection protocols on 320-slice volume

More information

Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT

Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT Eur Radiol (2006) 16: 1964 1972 DOI 10.1007/s00330-006-0262-x CARDIAC Sebastian Leschka Lars Husmann Lotus M. Desbiolles Oliver Gaemperli Tiziano Schepis Pascal Koepfli Thomas Boehm Borut Marincek Philipp

More information

Rotation: Imaging 2. Nuclear Cardiology (in Imaging 1 and 2)

Rotation: Imaging 2. Nuclear Cardiology (in Imaging 1 and 2) Rotation: Imaging 2 Imaging 2 provides addition nuclear cardiology experience and COCATS Level 1 cardiac MRI experience. Fellows administer, process, and read VHVI cardiac nuclear studies with cardiology

More information

A Snapshot on Nuclear Cardiac Imaging

A Snapshot on Nuclear Cardiac Imaging Editorial A Snapshot on Nuclear Cardiac Imaging Khalil, M. Department of Physics, Faculty of Science, Helwan University. There is no doubt that nuclear medicine scanning devices are essential tool in the

More information

The Final 10-Year Follow-up Results from the Bari Randomized Trial J Am Coll Cardiol (2007) 49;1600-6

The Final 10-Year Follow-up Results from the Bari Randomized Trial J Am Coll Cardiol (2007) 49;1600-6 The Final 10-Year Follow-up Results from the Bari Randomized Trial J Am Coll Cardiol (2007) 49;1600-6 n&list_uids=17433949 64-Multislice Detector Computed Tomography Coronary Angiography as Potential Alternative

More information

Isolated congenital coronary anomalies: Evaluation by multislice-ct or MRI

Isolated congenital coronary anomalies: Evaluation by multislice-ct or MRI Isolated congenital coronary anomalies: Evaluation by multislice-ct or MRI B.K. Velthuis, Dept. of Radiology UMC Utrecht, the Netherlands ESC 2010 Coronary artery anomalies CAA Uncommon 0.3-5% normal population

More information

CARDIAC MRI. Cardiovascular Disease. Cardiovascular Disease. Cardiovascular Disease. Overview

CARDIAC MRI. Cardiovascular Disease. Cardiovascular Disease. Cardiovascular Disease. Overview CARDIAC MRI Dr Yang Faridah A. Aziz Department of Biomedical Imaging University of Malaya Medical Centre Cardiovascular Disease Diseases of the circulatory system, also called cardiovascular disease (CVD),

More information

Case 47 Clinical Presentation

Case 47 Clinical Presentation 93 Case 47 C Clinical Presentation 45-year-old man presents with chest pain and new onset of a murmur. Echocardiography shows severe aortic insufficiency. 94 RadCases Cardiac Imaging Imaging Findings C

More information

Adult Echocardiography Examination Content Outline

Adult Echocardiography Examination Content Outline Adult Echocardiography Examination Content Outline (Outline Summary) # Domain Subdomain Percentage 1 2 3 4 5 Anatomy and Physiology Pathology Clinical Care and Safety Measurement Techniques, Maneuvers,

More information

Imaging congestive heart failure: role of coronary computed tomography angiography (CCTA)

Imaging congestive heart failure: role of coronary computed tomography angiography (CCTA) Imaging congestive heart failure: role of coronary computed tomography angiography (CCTA) Gianluca Pontone, MD, PhD, FESC, FSCCT Director of MR Unit Deputy Director of Cardiovascul CT Unit Clinical Cardiology

More information

CHAPTER. Quantification in cardiac MRI. This chapter was adapted from:

CHAPTER. Quantification in cardiac MRI. This chapter was adapted from: CHAPTER Quantification in cardiac MRI This chapter was adapted from: Quantification in cardiac MRI Rob J. van der Geest, Johan H.C. Reiber Journal of Magnetic Resonance Imaging 1999, Volume 10, Pages 602-608.

More information

Coronary CT Angiography

Coronary CT Angiography Coronary CT Angiography Byoung Wook Choi, M.D. Department of Diagnostic Radiology Yonsei University College of Medicine, Severance Hospital E mail : bchoi@yumc.yonsei.ac.kr Abstract With the advent of

More information

2019 Qualified Clinical Data Registry (QCDR) Performance Measures

2019 Qualified Clinical Data Registry (QCDR) Performance Measures 2019 Qualified Clinical Data Registry (QCDR) Performance Measures Description: This document contains the 18 performance measures approved by CMS for inclusion in the 2019 Qualified Clinical Data Registry

More information

Multimodality Imaging of Anomalous Left Coronary Artery from the Pulmonary

Multimodality Imaging of Anomalous Left Coronary Artery from the Pulmonary 1 IMAGES IN CARDIOVASCULAR ULTRASOUND 2 3 4 Multimodality Imaging of Anomalous Left Coronary Artery from the Pulmonary Artery 5 6 7 Byung Gyu Kim, MD 1, Sung Woo Cho, MD 1, Dae Hyun Hwang, MD 2 and Jong

More information

SYMPOSIA. Coronary CTA. Indications, Patient Selection, and Clinical Implications

SYMPOSIA. Coronary CTA. Indications, Patient Selection, and Clinical Implications SYMPOSIA Indications, Patient Selection, and Clinical Implications Christian Thilo, MD,* Mark Auler, MD,* Peter Zwerner, MD,w Philip Costello, MD,* and U. Joseph Schoepf, MD* Abstract: Recent technical

More information

Dr Felix Keng. Imaging of the heart is technically difficult because: Role of Cardiac MSCT. Current: Cardiac Motion Respiratory Motion

Dr Felix Keng. Imaging of the heart is technically difficult because: Role of Cardiac MSCT. Current: Cardiac Motion Respiratory Motion Siemens Philips Dr Felix Keng GE Toshiba Role of Cardiac MSCT Current: Structural / congenital heart imaging Extra-cardiac / Great vessel imaging Volumes and ejection fractions (cine + gating) Calcium

More information

Left ventricle pseudoaneurysm as late postoperative complication of a large apical aneurysm

Left ventricle pseudoaneurysm as late postoperative complication of a large apical aneurysm CASE REPORT Left ventricle pseudoaneurysm as late postoperative complication of a large apical aneurysm Mariana M. Floria 1, 4, Carmen Elena Pleșoianu 2, 4, Michel Buche 3, Baudouin Marchandise 4, Erwin

More information

Cardiac CT - Coronary Calcium Basics Workshop II (Basic)

Cardiac CT - Coronary Calcium Basics Workshop II (Basic) Cardiac CT - Coronary Calcium Basics Workshop II (Basic) J. Jeffrey Carr, MD, MSCE Dept. of Radiology & Public Health Sciences Wake Forest University School of Medicine Winston-Salem, NC USA No significant

More information

Review of Cardiac Imaging Modalities in the Renal Patient. George Youssef

Review of Cardiac Imaging Modalities in the Renal Patient. George Youssef Review of Cardiac Imaging Modalities in the Renal Patient George Youssef ECHO Left ventricular hypertrophy (LVH) assessment Diastolic dysfunction Stress ECHO Cardiac CT angiography Echocardiography - positives

More information

Contrast-enhanced echocardiography improves agreement on the assessment of ejection fraction and left ventricular function. A multicentre study

Contrast-enhanced echocardiography improves agreement on the assessment of ejection fraction and left ventricular function. A multicentre study Eur J Echocardiography 7 Suppl. 2 (2006) S16 S21 Contrast-enhanced echocardiography improves agreement on the assessment of ejection fraction and left ventricular function. A multicentre study Rainer Hoffmann*

More information

Cardiovascular Images

Cardiovascular Images Cardiovascular Images Pulmonary Embolism Diagnosed From Right Heart Changes Seen After Exercise Stress Echocardiography Brian C. Case, MD; Micheas Zemedkun, MD; Amarin Sangkharat, MD; Allen J. Taylor,

More information

RIGHT VENTRICULAR SIZE AND FUNCTION

RIGHT VENTRICULAR SIZE AND FUNCTION RIGHT VENTRICULAR SIZE AND FUNCTION Edwin S. Tucay, MD, FPCC, FPCC, FPSE Philippine Society of Echocardiography Quezon City, Philippines Echo Mission, BRTTH, Legaspi City, July 1-2, 2016 NO DISCLOSURE

More information

Reproducibility and Accuracy of Echocardiographic Measurements of Left Ventricular Parameters Using Real-Time Three-Dimensional Echocardiography

Reproducibility and Accuracy of Echocardiographic Measurements of Left Ventricular Parameters Using Real-Time Three-Dimensional Echocardiography Journal of the American College of Cardiology Vol. 44, No. 4, 2004 2004 by the American College of Cardiology Foundation ISSN 0735-1097/04/$30.00 Published by Elsevier Inc. doi:10.1016/j.jacc.2004.05.050

More information

A Magnetic Resonance Imaging Method for

A Magnetic Resonance Imaging Method for Journal of Cardiovascular Magnetic Resonance, 1(1), 59-64 (1999) INVITED PAPER Use of MRI in ASD Asessment A Magnetic Resonance Imaging Method for Evaluating Atrial Septa1 Defects Godtfred Holmvang Cardiac

More information

Little is known about the degree and time course of

Little is known about the degree and time course of Differential Changes in Regional Right Ventricular Function Before and After a Bilateral Lung Transplantation: An Ultrasonic Strain and Strain Rate Study Virginija Dambrauskaite, MD, Lieven Herbots, MD,

More information

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03 Introduction Cardiac Imaging Modalities Arnaud Bistoquet 12/19/03 Coronary heart disease: the vessels that supply oxygen-carrying blood to the heart, become narrowed and unable to carry a normal amount

More information

I have no financial disclosures

I have no financial disclosures Manpreet Singh MD I have no financial disclosures Exercise Treadmill Bicycle Functional capacity assessment Well validated prognostic value Ischemic assessment ECG changes ST segments Arrhythmias Hemodynamic

More information

Low Dose Era in Cardiac CT

Low Dose Era in Cardiac CT Low Dose Era in Cardiac CT DIANA E. LITMANOVICH, MD Department of Radiology Beth Israel Deaconess Medical Center Harvard Medical School Disclosures Neither I nor my immediate family members have a financial

More information

Assessment of L.V. Function by Multislice Cardiac Ct As Compared to 2d_Echocardiography

Assessment of L.V. Function by Multislice Cardiac Ct As Compared to 2d_Echocardiography THE MULTISLICE IRAQI POSTGRADUATE CARDIAC MEDICAL CT JOURNAL VOL. 14,NO.1, 2015 Assessment of L.V. Function by Multislice Cardiac Ct As Compared to 2d_Echocardiography Hayder Ryaid Abdul Satar*,Hasan Ali

More information

Index. Note: Page numbers of article titles are in boldface type.

Index. Note: Page numbers of article titles are in boldface type. Index Note: Page numbers of article titles are in boldface type. A Acute coronary syndrome(s), anticoagulant therapy in, 706, 707 antiplatelet therapy in, 702 ß-blockers in, 703 cardiac biomarkers in,

More information

B. CT protocols for the spine

B. CT protocols for the spine B. CT protocols for the spine Poster No.: A-003 Congress: ECR 2010 Type: Invited Speaker Topic: Neuro Authors: B. Tins; Oswestry/UK Keywords: CT, spine, diagnostic imaging protocol DOI: 10.1594/ecr2010/A-003

More information

Echocardiographic Assessment of the Left Ventricle

Echocardiographic Assessment of the Left Ventricle Echocardiographic Assessment of the Left Ventricle Theodora Zaglavara, MD, PhD, BSCI/BSCCT Department of Cardiovascular Imaging INTERBALKAN EUROPEAN MEDICAL CENTER 2015 The quantification of cardiac chamber

More information

Cover Page. The handle holds various files of this Leiden University dissertation.

Cover Page. The handle   holds various files of this Leiden University dissertation. Cover Page The handle http://hdl.handle.net/1887/19768 holds various files of this Leiden University dissertation. Author: Langevelde, Kirsten van Title: Are pulmonary embolism and deep-vein thrombosis

More information

Michael Rose 1, Bernard Rubal 1, Edward Hulten 2, Jennifer N Slim 1, Kevin Steel 1, James L Furgerson 1, Todd C Villines 2 and Ahmad M Slim 1

Michael Rose 1, Bernard Rubal 1, Edward Hulten 2, Jennifer N Slim 1, Kevin Steel 1, James L Furgerson 1, Todd C Villines 2 and Ahmad M Slim 1 522789SMO0010.1177/2050312114522789SAGE Open MedicineRose et al. research-article2014 Original Article SAGE Open Medicine Chamber dimensions and functional assessment with coronary computed tomographic

More information

RAMA-EGAT Risk Score for Predicting Coronary Artery Disease Evaluated by 64- Slice CT Angiography

RAMA-EGAT Risk Score for Predicting Coronary Artery Disease Evaluated by 64- Slice CT Angiography RAMA-EGAT Risk Score for Predicting Coronary Artery Disease Evaluated by 64- Slice CT Angiography Supalerk Pattanaprichakul, MD 1, Sutipong Jongjirasiri, MD 2, Sukit Yamwong, MD 1, Jiraporn Laothammatas,

More information

cardiac imaging planes planning basic cardiac & aortic views for MR

cardiac imaging planes planning basic cardiac & aortic views for MR cardiac imaging planes planning basic cardiac & aortic views for MR Dianna M. E. Bardo, M. D. Assistant Professor of Radiology & Cardiovascular Medicine Director of Cardiac Imaging cardiac imaging planes

More information

Jin Hur, MD 1 Tae Hoon Kim, MD 1 Sang Jin Kim, MD 1 Young Hoon Ryu, MD 1 Hyung Jung Kim, MD 2

Jin Hur, MD 1 Tae Hoon Kim, MD 1 Sang Jin Kim, MD 1 Young Hoon Ryu, MD 1 Hyung Jung Kim, MD 2 ssessment of the Right Ventricular Function and Mass Using Cardiac Multi-Detector Computed Tomography in Patients with Chronic Obstructive Pulmonary Disease Jin Hur, MD 1 Tae Hoon Kim, MD 1 Sang Jin Kim,

More information

SPECT-CT: Τι πρέπει να γνωρίζει ο Καρδιολόγος

SPECT-CT: Τι πρέπει να γνωρίζει ο Καρδιολόγος SPECT-CT: Τι πρέπει να γνωρίζει ο Καρδιολόγος Δρ Αναστασία Κίτσιου Διευθύντρια, Καρδιολογική Κλινική, Σισμανόγλειο ΓΝΑ Chair, Education Committee, Section on Nuclear Cardiology & Cardiac CT, EACVI, ESC

More information

Doppler-echocardiographic findings in a patient with persisting right ventricular sinusoids

Doppler-echocardiographic findings in a patient with persisting right ventricular sinusoids Zurich Open Repository and Archive University of Zurich Main Library Strickhofstrasse 39 CH-8057 Zurich www.zora.uzh.ch Year: 1990 Doppler-echocardiographic findings in a patient with persisting right

More information

Coronary Artery Imaging. Suvipaporn Siripornpitak, MD Inter-hospital Conference : Rajavithi Hospital

Coronary Artery Imaging. Suvipaporn Siripornpitak, MD Inter-hospital Conference : Rajavithi Hospital Coronary Artery Imaging Suvipaporn Siripornpitak, MD Inter-hospital Conference : Rajavithi Hospital Larger array : cover scan area Detector size : spatial resolution Rotation speed : scan time Retrospective

More information

Combined Anatomical and Functional Imaging with Revolution * CT

Combined Anatomical and Functional Imaging with Revolution * CT GE Healthcare Case studies Combined Anatomical and Functional Imaging with Revolution * CT Jean-Louis Sablayrolles, M.D. Centre Cardiologique du Nord, Saint-Denis, France Case 1 Whole Brain Perfusion and

More information

Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography

Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography Journal of the American College of Cardiology Vol. 46, No. 3, 2005 2005 by the American College of Cardiology Foundation ISSN 0735-1097/05/$30.00 Published by Elsevier Inc. doi:10.1016/j.jacc.2005.05.056

More information

Automatic cardiac contour propagation in short axis cardiac MR images

Automatic cardiac contour propagation in short axis cardiac MR images International Congress Series 1281 (2005) 351 356 www.ics-elsevier.com Automatic cardiac contour propagation in short axis cardiac MR images G.L.T.F. Hautvast a,b, T, M. Breeuwer a, S. Lobregt a, A. Vilanova

More information

Cardiopulmonary Imaging Original Research

Cardiopulmonary Imaging Original Research Cardiopulmonary Imaging Original Research Bischoff et al. Versus Helical Mode for Coronary CTA Cardiopulmonary Imaging Original Research Bernhard Bischoff 1 Franziska Hein 1 Tanja Meyer 1 Markus Krebs

More information

Analysis of Left Ventricular Function

Analysis of Left Ventricular Function Analysis of Left Ventricular Function from Multiple Gated Acquisition Cardiac Blood Pool Imaging Comparison to Contrast Angiography ROBERT D. BUROW, B.S., H. WILLIAM STRAUSS, M.D., Ross SINGLETON, PH.D.,

More information

Computed tomography. Department of Radiology, University Medical School, Szeged

Computed tomography. Department of Radiology, University Medical School, Szeged Computed tomography Department of Radiology, University Medical School, Szeged voxel +1-4 +2 +5 +3 +1 0-2 pixel -2 0 +1-4 -6 +5 +2 +1 Department of Radiology, University Medical School, Szeged

More information

LV function in ischemic heart failure - decreased correlation between Echo and CMR

LV function in ischemic heart failure - decreased correlation between Echo and CMR LV function in ischemic heart failure - decreased correlation between Echo and CMR Poster No.: C-0590 Congress: ECR 2011 Type: Scientific Exhibit Authors: K. Gruszczy#ska, L. Krzych, K. Golba, P. Ulbrych,

More information

PART II ECHOCARDIOGRAPHY LABORATORY OPERATIONS ADULT TRANSTHORACIC ECHOCARDIOGRAPHY TESTING

PART II ECHOCARDIOGRAPHY LABORATORY OPERATIONS ADULT TRANSTHORACIC ECHOCARDIOGRAPHY TESTING PART II ECHOCARDIOGRAPHY LABORATORY OPERATIONS ADULT TRANSTHORACIC ECHOCARDIOGRAPHY TESTING STANDARD - Primary Instrumentation 1.1 Cardiac Ultrasound Systems SECTION 1 Instrumentation Ultrasound instruments

More information

128-slice dual-source CT coronary angiography using highpitch scan protocols in 102 patients

128-slice dual-source CT coronary angiography using highpitch scan protocols in 102 patients 128-slice dual-source CT coronary angiography using highpitch scan protocols in 102 patients Poster No.: C-0634 Congress: ECR 2010 Type: Scientific Exhibit Topic: Cardiac Authors: Y. H. Choe, J. W. Lee,

More information

left atrial myxoma causes paradoxical motion of the catheter; posterior

left atrial myxoma causes paradoxical motion of the catheter; posterior Am JRoentgenolla6:II55-II58, 1976 ABNORMAL LEFT VENTRICULAR CATHETER MOTION: AN ANCILLARY ANGIOGRAPHIC SIGN OF LEFT ATRIAL MYXOMA ABsTRACT: J. M. RAU5CH, R. T. REINKE, K. L. PETERSON,2 AND C. B. HIGGINs

More information

A new method for radiation dose reduction at cardiac CT with multi-phase data-averaging and non-rigid image registration: preliminary clinical trial

A new method for radiation dose reduction at cardiac CT with multi-phase data-averaging and non-rigid image registration: preliminary clinical trial A new method for radiation dose reduction at cardiac CT with multi-phase data-averaging and non-rigid image registration: preliminary clinical trial Poster No.: C-0595 Congress: ECR 2013 Type: Authors:

More information

Cigna - Prior Authorization Procedure List: Radiology & Cardiology

Cigna - Prior Authorization Procedure List: Radiology & Cardiology Cigna - Prior Authorization Procedure List: Radiology & Cardiology Category CPT Code CPT Code Description 93451 Right heart catheterization 93452 Left heart catheterization 93453 Combined right and left

More information

Chapter 6. Hester Gietema Cornelia Schaefer-Prokop Willem Mali Gerard Groenewegen Mathias Prokop. Accepted for publication in Radiology

Chapter 6. Hester Gietema Cornelia Schaefer-Prokop Willem Mali Gerard Groenewegen Mathias Prokop. Accepted for publication in Radiology Chapter 6 Interscan variability of semiautomated volume measurements in intraparenchymal pulmonary nodules using multidetector-row computed tomography: Influence of inspirational level, nodule size and

More information

PULMONARY EMBOLISM ANGIOCT (CTA) ASSESSMENT OF VASCULAR OCCLUSION EXTENT AND LOCALIZATION OF EMBOLI 1. BACKGROUND

PULMONARY EMBOLISM ANGIOCT (CTA) ASSESSMENT OF VASCULAR OCCLUSION EXTENT AND LOCALIZATION OF EMBOLI 1. BACKGROUND JOURNAL OF MEDICAL INFORMATICS & TECHNOLOGIES Vol. 11/2007, ISSN 1642-6037 Damian PTAK * pulmonary embolism, AngioCT, postprocessing techniques, Mastora score PULMONARY EMBOLISM ANGIOCT (CTA) ASSESSMENT

More information

2004;77:800 4 MSCT OF CORONARY ARTERY BYPASS GRAFTS. Results. CABG With Adequate Diagnostic Quality

2004;77:800 4 MSCT OF CORONARY ARTERY BYPASS GRAFTS. Results. CABG With Adequate Diagnostic Quality Isotropic Half-Millimeter Angiography of Coronary Artery Bypass Grafts With 16-Slice Computed Tomography Marc Dewey, MD, Alexander Lembcke, MD, Christian Enzweiler, MD, Bernd Hamm, MD, and Patrik Rogalla,

More information

Managing Hypertrophic Cardiomyopathy with Imaging. Gisela C. Mueller University of Michigan Department of Radiology

Managing Hypertrophic Cardiomyopathy with Imaging. Gisela C. Mueller University of Michigan Department of Radiology Managing Hypertrophic Cardiomyopathy with Imaging Gisela C. Mueller University of Michigan Department of Radiology Disclosures Gadolinium contrast material for cardiac MRI Acronyms Afib CAD Atrial fibrillation

More information

Improved Noninvasive Assessment of Coronary Artery Bypass Grafts With 64-Slice Computed Tomographic Angiography in an Unselected Patient Population

Improved Noninvasive Assessment of Coronary Artery Bypass Grafts With 64-Slice Computed Tomographic Angiography in an Unselected Patient Population Journal of the American College of Cardiology Vol. 49, No. 9, 2007 2007 by the American College of Cardiology Foundation ISSN 0735-1097/07/$32.00 Published by Elsevier Inc. doi:10.1016/j.jacc.2006.10.066

More information

ECG-gated multidetector-row computed tomography in the assessment of left ventricular function

ECG-gated multidetector-row computed tomography in the assessment of left ventricular function REVIEW ECG-gated multidetector-row computed tomography in the assessment of left ventricular function An accurate quantitative and qualitative assessment of cardiac function is critical for clinical diagnosis,

More information

MSRS 6473 Vascular Noninvasive Imaging Procedures

MSRS 6473 Vascular Noninvasive Imaging Procedures MSRS 6473 Vascular Noninvasive Imaging Procedures Rex T. Christensen MHA RT (R) (MR) (CT) (ARRT) CIIP Basic Physics Equipment Cardiac Positioning Perfusion Pathology MRI 1 Animal Magnetism MRI Basic Physics

More information

Comparison of Cardiac MDCT with MRI and Echocardiography in the Assessement of Left Ventricular Function

Comparison of Cardiac MDCT with MRI and Echocardiography in the Assessement of Left Ventricular Function Comparison of Cardiac MDCT with MRI and Echocardiography in the Assessement of Left Ventricular Function Poster No.: C-0969 Congress: ECR 2012 Type: Scientific Exhibit Authors: B. Kara, Y. Paksoy, C. Erol,

More information

10/7/2013. Systolic Function How to Measure, How Accurate is Echo, Role of Contrast. Thanks to our Course Director: Neil J.

10/7/2013. Systolic Function How to Measure, How Accurate is Echo, Role of Contrast. Thanks to our Course Director: Neil J. Systolic Function How to Measure, How Accurate is Echo, Role of Contrast Neil J. Weissman, MD MedStar Health Research Institute & Professor of Medicine Georgetown University Washington, D.C. No Disclosures

More information

Case Report. Heon Lee, MD, PhD 1, Seok-Yeon Kim, MD 2, U. Joseph Schoepf, MD 3 CASE REPORT INTRODUCTION

Case Report. Heon Lee, MD, PhD 1, Seok-Yeon Kim, MD 2, U. Joseph Schoepf, MD 3 CASE REPORT INTRODUCTION Case Report http://dx.doi.org/10.3348/kjr.2012.13.2.244 pissn 1229-6929 eissn 2005-8330 Korean J Radiol 2012;13(2):244-248 Isolated Non-Compaction of the Left Ventricle in a Patient with New-Onset Heart

More information

Policy #: 222 Latest Review Date: March 2009

Policy #: 222 Latest Review Date: March 2009 Name of Policy: MRI Phase-Contrast Flow Measurement Policy #: 222 Latest Review Date: March 2009 Category: Radiology Policy Grade: Active Policy but no longer scheduled for regular literature reviews and

More information

Radiation dose of cardiac CT what is the evidence?

Radiation dose of cardiac CT what is the evidence? Eur Radiol (2009) 19: 1311 1315 DOI 10.1007/s00330-009-1312-y CARDIAC Hatem Alkadhi Radiation dose of cardiac CT what is the evidence? Received: 10 December 2008 Revised: 2 January 2009 Accepted: 12 January

More information

ECG Gated CT Aorta in Transcatheter Aortic Valve Implantation

ECG Gated CT Aorta in Transcatheter Aortic Valve Implantation ECG Gated CT Aorta in Transcatheter Aortic Valve Implantation Poster No.: C-2014 Congress: ECR 2014 Type: Educational Exhibit Authors: M. A. Ottesen; Oslo/NO Keywords: Cardiac, Arteries / Aorta, CT, CT-Angiography,

More information

좌심실수축기능평가 Cardiac Function

좌심실수축기능평가 Cardiac Function Basic Echo Review Course 좌심실수축기능평가 Cardiac Function Seonghoon Choi Cardiology Hallym university LV systolic function Systolic function 좌심실수축기능 - 심근의수축으로심실에서혈액을대동맥으로박출하는기능 실제임상에서 LV function 의의미 1Diagnosis

More information

Global left ventricular circumferential strain is a marker for both systolic and diastolic myocardial function

Global left ventricular circumferential strain is a marker for both systolic and diastolic myocardial function Global left ventricular circumferential strain is a marker for both systolic and diastolic myocardial function Toshinari Onishi 1, Samir K. Saha 2, Daniel Ludwig 1, Erik B. Schelbert 1, David Schwartzman

More information

Impact of the ECG gating method on ventricular volumes and ejection fractions assessed by cardiovascular magnetic resonance imaging

Impact of the ECG gating method on ventricular volumes and ejection fractions assessed by cardiovascular magnetic resonance imaging Journal of Cardiovascular Magnetic Resonance (2005) 7, 441 446 Copyright D 2005 Taylor & Francis Inc. ISSN: 1097-6647 print / 1532-429X online DOI: 10.1081/JCMR-200053515 VENTRICULAR FUNCTION Impact of

More information

Cigna - Prior Authorization Procedure List Cardiology

Cigna - Prior Authorization Procedure List Cardiology Cigna - Prior Authorization Procedure List Cardiology Category CPT Code CPT Code Description 33206 Insertion of new or replacement of permanent pacemaker with transvenous electrode(s); atrial 33207 Insertion

More information

27-year-old professionnal rugby player: asymptomatic

27-year-old professionnal rugby player: asymptomatic 27-year-old professionnal rugby player: asymptomatic Benefits and limits of cardiac MRI in the young athlete with a suspected heart disease. Philippe PAULE Service de Cardiologie, HIA Clermont Tonnerre,

More information

A ortic stenosis (AS) is the most common valvular disease

A ortic stenosis (AS) is the most common valvular disease 1121 VALVULAR HEART DISEASE Comprehensive evaluation of preoperative patients with aortic valve stenosis: usefulness of cardiac multidetector computed tomography Jean-Pierre Laissy, David Messika-Zeitoun,

More information