CPM Specifications Document Aortofemoral Normal:

Size: px
Start display at page:

Download "CPM Specifications Document Aortofemoral Normal:"

Transcription

1 CPM Specifications Document Aortofemoral Normal: OSMSC 0003_ _0000 May 24, 2013 Version 1 Open Source Medical Software Corporation 2013 Open Source Medical Software Corporation. All Rights Reserved.

2 1. Clinical Significance & Condition Studying the hemodynamics of the vasculature distal to the abdominal aorta may be important in understanding common diseases in peripheral arteries downstream of the thoracic aorta. Diseases in the peripheral vasculature affect millions of people in the U.S and can have a profound effect on daily quality of life. Peripheral arterial disease is the build-up of fatty tissue, or atherosclerosis, in lower extremity arteries. By 2001 at least 10 million people in the U.S were estimated to have peripheral arterial disease. The prevalence of peripheral arterial occlusive disease increases with age and can increase to up to 20% of the population in the geriatric population [1]. Up to 4 million people in the U.S suffer from intermittent claudication causing pain in the legs during exercise. Atherosclerotic occlusive disease of the lower extremity arteries is a major cause of walking impairment, pain, ulcerations and gangrene. Renal artery stenosis can have a prevalence of up to 45% in selective populations, specifically populations with other vascular disease. Prevalence can be from 1-6% in hypertensive patients to 30-45% in patients with aortoiliac occlusive disease or abdominal aortic aneurysms [1]. It is most often caused by atherosclerosis in the renal arteries and is often undetected until symptoms become severe. The most common symptom of renal artery stenosis is hypertension, which can have significant effects on the entire vascularture. Up to 24% of patients with renal insuffiency, which can lead to end-stage renal disease renal disease, had renal artery stenosis, suggesting that renal artery stenosis may play an important role in kidney failure [1]. 2. Clinical Data Patient-specific volumetric image data was obtained to create physiological models and blood flow simulations. Details of the imaging data used can be seen in Table 1. See Appendix 1 for details on image data orientation. Table 1 Patient-specific volumetric image data details (mm). Voxel Spacing, voxel dimensions, and physical dimensions are provided in the Right-Left (R), Anterior-Posterior (A), and Superior-Inferior (S) direction. OSMSC ID Modality Voxel Spacing Voxel Dimensions Physical Dimensions R A S R A S R A S 0003_0000 CT _0000 MR Open Source Medical Software Corporation. All Rights Reserved. Page 2

3 Patient specific clinical data can be seen in Table 2.Note that no patient specific clinical data other than age and gender were available for patient 0003_0000. Table 2 Available patient-specific clinical data OSMSC ID Age Gender Height Weight DP (mmhg) MP (mmhg) SP (mmhg) 0003_ F _ M Anatomic Model Description Anatomic models were created using customized SimVascular software (Simtk.org) and the image data described in Section 2. Aortofemoral models extend from the ascending or thoracic aorta to the femoral arteries. See Table 3 for a visual summary of the image data, paths, segmentations and solid model constructed. Table 3 Visual summary of image data, paths, segmentations and solid model. OSMSC ID Image Data Paths Paths and Segmentations Model ID: OSMSC0003 subid: 0000 Age: 21 Gender: F 2013 Open Source Medical Software Corporation. All Rights Reserved. Page 3

4 ID: OSMSC0006 subid: 0000 Age: 30 Gender: M Details of anatomic models, such has number of outlets and model volume, can be seen in Table 4. OSMSC ID Inlets Outlets (cm 3 ) Table 4 Anatomic Model details Volume (cm 2 ) Surface Area (cm 2 ) Vesel Paths 2-D Segementations 0003_ _ Physiological Model Description In addition to the clinical data gathered for this model, several physiological assumptions were made in preparation for running the simulation. See Appendix 3 for details. 5. Simulation Parameters & Details 5. 1 Simulation Parameters See Appendix 4 for information on the physiology and simulation specifications. Simulation Parameters are shown in Table 5. Table 5- Simulation Parameters OSMSC ID Time Steps per Cycle Time Stepping Strategy 0003_ fixed_step _ fixed_step Open Source Medical Software Corporation. All Rights Reserved. Page 4

5 5. 2 Inlet Boundary Conditions For 0003_0000 the inflow waveform was adapted from Olufsen et. al. and then smoothed [2]. The mean value of the inflow waveform was reasonably in the range of mean cardiac output of 4.6 L/min given for women in Collis and the standard 5.0 L/min given in Berne and Levy [3, 4]. For 0006_0000, clinically acquired patient height and weight were used to calculate patient BSA based on the Moseller equation. The BSA was then used to calculate the cardiac output based on the Baker equation. Flow to the supraceliac aorta was assumed to be 66% of the cardiac output [5, 6]. Patient-specific inflow waveforms were created by scaling a gender-matched representative supraceliac aortic waveform. Inflow waveforms were prescribed to the inlets of the computational fluid dynamics (CFD) models (Figure 1). See Table 6 for the period and prescribed cardiac inflow for each simulation. Table 6 Period and Cardiac Output from waveforms seen in Figure 1 OSMSC ID Period (s) Cardiac Output (L/min) Profile Type 0003_ Womersley 0006_ Womersley 2013 Open Source Medical Software Corporation. All Rights Reserved. Page 5

6 Figure 1 Inflow waveforms in L/min 5. 3 Outlet Boundary Conditions A three element Windkessel model was applied at each outlet. For more information refer to Exhibit 1 and Appendix 5. To define the parameters in the Windkessel model the mean flow to each outlet was calculated. For both 0003 and 0006 various literature sources were used to calcite the outflow to each artery. Target flow splits are shown in 2013 Open Source Medical Software Corporation. All Rights Reserved. Page 6

7 Table _0000: It is thought that 10-18% of total cardiac output goes to the brain [7, 8, 9, 10, 11]. From this range, 13% of cardiac output to the brain was selected (6.5% to each carotid artery). Because 65% of cardiac output is thought to go down the descending thoracic aorta, then the remaining 22% of cardiac output was assumed to enter the subclavian arteries (11% to each subclavian) [12]. The thoracic aortic flow (65% of the total cardiac output) is equal to the flow entering the abdominal aorta at the supraceliac level. The amount of flow entering the infrarenal aorta was determined from a ratio of infrarenal to supraceliac flow from Cheng and colleagues [13]. Because the supraceliac and infrarenal flow were calculated, the total amount of flow exiting the upper branch vessels (the hepatic, splenic, SMA, and left and right renal arteries) could be determined. This flow to the upper branch vessels was distributed to each upper branch vessel according to measurements made by Moore and Ku [14]. The remaining aortic infrarenal flow was divided equally to the right and left common iliac arteries. From each common iliac artery, each external iliac artery received 70% and each internal iliac received 30% of the common iliac flow flow [15]. The desired flow to the right and left femoral, profunda, and external circumflex arteries was based approximately on the areas of their outlets. 0006_0000: Flow to the supraceliac aorta was taken as 66% of the cardiac output [5, 6]. From the supraceliac flow 21.7% was prescribed to the celiac artery and 14.7% to the superior mesenteric artery [16]. The flow to the celiac artery was split evenly between the hepatic and splenic artery. About 23.3% of cardiac output is thought to go to the kidneys [17]. This flow was also split evenly between the right and left renal arteries. This leaves 29.8% of the remaining flow from the supraceliac aorta to flow through the infrarenal aorta, which is consistent with findings from Cheng et. al. based on PCMRI flow data collected in healthy male subjects ages 20 to 24 years [18]. The remaining flow to the infrarenal aorta was then split evenly between the left and right common iliac arteries. That flow was then distributed to the external iliac and internal iliac arteries at a 70% and 30% of the common iliac artery flow respectively. Target Pressures for 0003_0000 were set based on typical pressures for healthy adults, while target pressures for 0006_0000 were based on clinically-acquired pressure measurements. See Table 6 for target pressures Open Source Medical Software Corporation. All Rights Reserved. Page 7

8 Table 7 Flow distributions and Pressures OSMSC ID 0003_ _0000 Hepatic 7.6% 10.8% Left External Iliac % Left Femoral 2.6% - Left Internal Iliac 2.8% 4.5% Left Profunda 1.3% - Left Renal 10.4% 16.9% Left Common Carotid 6.6% - Left External Circumflex 2.6% - Left Subclavian 11.0% - Right External Iliac % Right Femoral 2.6% - Right Internal Iliac 2.8% 4.5% Right Profunda 1.3% - Right Renal 10.5% 16.9% Right Common Carotid 6.6% - Right External Circumflex 2.6% - Right Subclavian 11.0% - Superior Mesenteric 10.3% 14.7% Splenic 7.5% 10.8% Systolic Pressure (mmhg) Diastolic Pressure (mmhg) Mean Pressure (mmhg) Simulation Results Simulation results were quantified for the last cardiac cycle. Paraview (Kitware, Clifton Park, NY), an opensource scientific visualization application, was used to visualize the results. A volume rendering of velocity magnitude for three time points during the cardiac cycle can be seen in 2013 Open Source Medical Software Corporation. All Rights Reserved. Page 8

9 Table 8 for each model Open Source Medical Software Corporation. All Rights Reserved. Page 9

10 Table 8 Volume rendering velocity during peak systole, end systole, and end diastole. All renderings have the scale below with units of cm/s OSMSC ID Peak Systole End Systole End Diastole ID: OSMSC0003 subid: 0000 Age: 21 Gender: F ID: OSMSC0006 subid: 0000 Age: 30 Gender: M 2013 Open Source Medical Software Corporation. All Rights Reserved. Page 10

11 Surface distribution of time-averaged blood pressure (TABP), time-averaged wall shear stress (TAWSS) and oscillatory shear index (OSI) were also visualized and can be seen in Table 9. Table 9 Time averaged blood pressure (TABP), time-average wall shear stress (TAWSS), and oscillatory shear index (OSI) surface distributions OSMSC ID TABP TAWSS OSI ID: OSMSC0003 subid: 0000 Age: 21 Gender: F ID: OSMSC0006 subid: 0000 Age: 30 Gender: M 2013 Open Source Medical Software Corporation. All Rights Reserved. Page 11

12 7. References [1] W. R. Hiatt, A. T. Hirsch and J. Regensteiner, Peripheral Artery Disease Handbook, Boca Raton, FL: CRC Press LLC, [2] M. Olufsen, C. Peskin, W. Kim, E. Pedersen, A. Nadim and J. Larsen, "Numerical simulation and experimental validation of blood flow in arteries with structured-tree outflow conditions," Annals of Biomediacl Engineering, vol. 28, pp , [3] T. Collis, R. Devereux, M. Roman, G. de Simone, J. Yeh, B. Howard, R. Fabsitz and T. Welty, "Relations of stroke volume and cardiac output to body composition - the strong heart study," Circulation, vol. 103, pp , [4] R. Berne and M. Levy, " Cardiovascular Physiology," no. 8th Edition, [5] P. Reymond, F. Merenda, F. Perren, D. Rufenacht and N. Stergiopulos, "Validation of a One-Dimensional Model of the Systemic Arterial Tree," Am J Physiol Heart Circ Physiol, no. 297, pp. H208-H222, [6] B. N. Steele, M. S. Olufsen and C. A. Taylor, "Fractal network for Simulating Abdominal and Lower Extremity Blood Flow During Resting and Exercise Conditions," Comput. Methods Biomech. Biomed Engin., vol. 10, no. 1, pp , [7] L. Williams et. al., "Reference values for resting blood flow to organs of man," Clin. Phys. Physiol. Meas., vol. 10, no. 3, pp , [8] H. Keller at. al., "Noninvasive Measurement of Velocity Profiles and Blood Flow in the Common Carotid Artery by Pulsed Doppler Ultrasound," Stroke, vol. 7, no. 4, pp , [9] P. Scheel et. al., "Color Duplex Measurement of Cerebral Blood Flow Volume in Healthy Adults," Stroke, vol. 31, pp , [10] B. Chu et. al., "Flow Volume in the Common Carotid Artery Detected by Color Duplex Sonography: An Approach to the Normal Value and Predictability of Cerebral Blood Flow.," Radiation Medicina, vol. 18, no. 4, pp , [11] H. Bogren et. al., "Blood Flow Measurements in the Aorta and Major Arteries with MR Velocity Mapping," JMRI, vol. 4, pp , [12] F. Nicoud et. al., "Integral Boundary Conditions for Unsteady Biomedical CFD Applications," Int. J. Numer. Meth. Fluids, vol. 40, pp , [13] C. Cheng, R. Herfkens and C. Taylor, "Comparison of abdominal aortic hemodynamics between men and women at rest and during lower limb exercise," Journal of Vascular Surgery, vol. 37, pp , Open Source Medical Software Corporation. All Rights Reserved. Page 12

13 [14] J. J. Moore and D. Ku, "Pulsatile velocity measurements in a model of the human abdominal aorta under resting conditions," J Biomech Eng., vol. 116, pp , [15] B. Steele, M. Olufsen and C. Taylor, "Fractal network model for simulating abdominal and lower extremity blood flow during resting and exercise conditions," Computer Methods in Biomechanics and Biomedical Engineering, vol. 10, pp , [16] J. E. Moore Jr. and D. N. Ku, "Pulsatile Velocity Meaurements in a Model of the Human Abdominal aorta Under Resting Conditions," ASME Journal of Biomechanical Engineering, vol. 116, pp , [17] W. W. Nichols, M. F. Rourke and C. Vlachopoulos, McDonald's Blood Flow Arteries: Theoretical, Experimental and Clinical Principles, London: Hoddel Arnold, [18] C. P. Cheng, R. J. Herfkens and C. A. Taylor, "Comparison of Abdominal Aortic Hemodynamics Between Men and Women at Rest and During Lowe Limb Exercise," Journal of Vascular Surgery, vol. 37, no. 1, pp , Open Source Medical Software Corporation. All Rights Reserved. Page 13

14 Exhibit 1: Aortofemoral Simulations RCR Values Information on how RCR values were obtained is included in Appendix 5. RCR values for the final simulations are shown on Tables 9 and 10 for 0003_0000 and 0006_0000 respectively. Table 10 RCR Values for 0003_0000 in cgs Solver ID Face Name Artery Name Rp C Rd 2 Brachiocephalic_Right_Subclavian Right Subclavian Right_Common_Carotid Right Common Carotid Left_Common_Carotid Left Common Carotid Left_Subclavian Left Subclavian Celiac_Hepatic Hepatic Splenic Splenic SMA Superior Mesenteric Left_Renal Left Renal Right_Renal Right Renal Left_Internal Left Internal Right_Internal Right Internal Left_Profunda Left Profunda Right_Profunda Right Profunda Left_Profunda_2 Left External Circumflex Right_Profunda_2 Right External Circumflex Aorta_Smoothed Left Femoral Common_External_Femoral Right Femoral Table 11 RCR values for 0006_0000 in cgs Solver ID Face Name Artery Name Rp C Rd 2 hepatic Heptic splenic Splenic SMA Superior Mesenteric right_renal Right Renal left_renal Left Renal right_internal_iliac Right Internal Iliac left_internal_iliac Left Internal Iliac right_external_iliac Right External Iliac left_external_iliac Left External Iliac Open Source Medical Software Corporation. All Rights Reserved. Page 14

15 Appendix 1. Image Data Orientation The RAS coordinate system was assumed for the image data orientation. Voxel Spacing, voxel dimensions, and physical dimensions are provided in the Right-Left (R), Anterior-Posterior (A), and Superior-Inferior (S) direction in all specification documents unless otherwise specified. 2. Model Construction All anatomic models were constructed in RAS Space. The models are generated by selecting centerline paths along the vessels, creating 2D segmentations along each of these paths, and then lofting the segmentations together to create a solid model. A separate solid model was created for each vessel and Boolean addition was used to generate a single model representing the complete anatomic model. The vessel junctions were then blended to create a smoothed model. 3. Physiological Assumptions Newtonian fluid behavior is assumed with standard physiological properties. Blood viscosity and density are given below in units used to input directly into the solver. Blood Viscosity: 0.04 g/cm s 2 Blood Density: 1.06 g/cm 3 4. Simulation Parameters Conservation of mass and Navier-Stokes equations were solved using 3D finite element methods assuming rigid and non-slip walls. All simulations were ran in cgs units and ran for several cardiac cycles to allow the flow rate and pressure fields to stabilize. 5. Outlet Boundary Conditions 5.1 Resistance Methods Resistances values can be applied to the outlets to direct flow and pressure gradients. Total resistance for the model is calculated using relationships of the flow and pressure of the model. Total resistance is than distributed amongst the outlets using an inverse relationship of outlet area and the assumption that the outlets act in parallel. 5.2 Windkessel Model In order to represent the effects of vessels distal to the CFD model, a three-element Windkessel model can be applied at each outlet. This model consists of proximal resistance (R p ), capacitance (C), and distal resistance (R d ) representing the resistance of the proximal vessels, the capacitance of the proximal vessels, and the resistance of the distal vessels downstream of each outlet, respectively (Figure 1). Figure 2 - Windkessel model 2013 Open Source Medical Software Corporation. All Rights Reserved. Page 15

16 First, total arterial capacitance (TAC) was calculated using inflow and blood pressure. The TAC was then distributed among the outlets based on the blood flow distributions. Next, total resistance (R t ) was calculated for each outlet using mean blood pressure and PC-MRI or calculated target flow (R t =P mean /Q desired ). Given that R t =R p +R d, total resistance was distributed between R p and R d adjusting the R p to R t ratio for each outlet Open Source Medical Software Corporation. All Rights Reserved. Page 16

CPM Specifications Document Aortofemoral Normal:

CPM Specifications Document Aortofemoral Normal: CPM Specifications Document Aortofemoral Normal: OSMSC 0110_0000 May 27, 2013 Version 1 Open Source Medical Software Corporation 2013 Open Source Medical Software Corporation. All Rights Reserved. 1. Clinical

More information

CPM Specifications Document Aortic Coarctation: Exercise

CPM Specifications Document Aortic Coarctation: Exercise CPM Specifications Document Aortic Coarctation: Exercise OSMSC 0091_2000 0102_2000 0107_0000 0111_0000 May 29, 2013 Version 1 Open Source Medical Software Corporation 2013 Open Source Medical Software

More information

CPM Specifications Document Fontan - Exercise:

CPM Specifications Document Fontan - Exercise: CPM Specifications Document Fontan - Exercise: OSMSC 0063_2000, 0063_3000, 0063_4000, 0064_2000, 0064_3000, 0064_4000, 0065_2000, 0065_3000, 0065_4000, 0075_2000, 0075_3000, 0075_4000, 0076_2000, 0076_3000,

More information

CPM Specifications Document Fontan Aorta - Exercise:

CPM Specifications Document Fontan Aorta - Exercise: CPM Specifications Document Fontan Aorta - Exercise: OSMSC 0063_1000, 0064_1000, 0065_1000, 0075_1000, 0076_1000, 0077_1000 May 1, 2013 Version 1 Open Source Medical Software Corporation 2013 Open Source

More information

CFD Challenge: Simulation of Hemodynamics in a Patient-Specific Aortic Coarctation Model

CFD Challenge: Simulation of Hemodynamics in a Patient-Specific Aortic Coarctation Model CFD Challenge: Simulation of Hemodynamics in a Patient-Specific Aortic Coarctation Model Background Coarctation of the aorta (CoA) accounts for 8%-11% of congenital heart defects, affecting tens of thousands

More information

Numerical simulations of fluid mechanical interactions between two abdominal aortic branches

Numerical simulations of fluid mechanical interactions between two abdominal aortic branches Korea-Australia Rheology Journal Vol. 16, No. 2, June 2004 pp. 75-83 Numerical simulations of fluid mechanical interactions between two abdominal aortic branches Taedong Kim, Taewon Seo* 1,2 and Abdul.I.

More information

Refinements in Mathematical Models to Predict Aneurysm Growth and Rupture

Refinements in Mathematical Models to Predict Aneurysm Growth and Rupture Refinements in Mathematical Models to Predict Aneurysm Growth and Rupture RAMON BERGUER, a,b JOSEPH L. BULL, a,b AND KHALIL KHANAFER a a Vascular Mechanics Laboratory, Department of Biomedical Engineering,

More information

CFD Analysis of Pulsatile Flow and Non-Newtonian Behavior of Blood in Arteries

CFD Analysis of Pulsatile Flow and Non-Newtonian Behavior of Blood in Arteries Copyright 2015 Tech Science Press MCB, vol.12, no.1, pp.37-47, 2015 CFD Analysis of Pulsatile Flow and Non-Newtonian Behavior of Blood in Arteries P. Jhunjhunwala,, P.M. Padole, and S.B. Thombre, Abstract:

More information

Artery 1 Head and Thoracic Arteries. Arrange the parts in the order blood flows through them.

Artery 1 Head and Thoracic Arteries. Arrange the parts in the order blood flows through them. Artery 1 Head and Thoracic Arteries 1. Given the following parts of the aorta: 1. abdominal aorta 2. aortic arch 3. ascending aorta 4. thoracic aorta Arrange the parts in the order blood flows through

More information

Radiologic Evaluation of Peripheral Arterial Disease

Radiologic Evaluation of Peripheral Arterial Disease January 2003 Radiologic Evaluation of Peripheral Arterial Disease Grace Tye, Harvard Medical School Year III Patient D.M. CC: 44 y/o male with pain in his buttocks Occurs after walking 2 blocks. Pain is

More information

Non-Newtonian pulsatile blood flow in a modeled artery with a stenosis and an aneurysm

Non-Newtonian pulsatile blood flow in a modeled artery with a stenosis and an aneurysm Non-Newtonian pulsatile blood flow in a modeled artery with a stenosis and an aneurysm I. Husain, C. Langdon and J. Schwark Department of Mathematics Luther College University of Regina Regina, Saskatchewan

More information

Blood Flow Simulation toward Actual Application at Hospital

Blood Flow Simulation toward Actual Application at Hospital THE 5 TH ASIAN COMPUTAITIONAL FLUID DYNAMICS BUSAN, KOREA, OCTOBER 27 ~ OCTOBER 30, 2003 Blood Flow Simulation toward Actual Application at Hospital Abstract R. Himeno 1 1. Advanced Center for Computing

More information

Finite Element Modeling of Three-Dimensional Pulsatile Flow in the Abdominal Aorta: Relevance to Atherosclerosis

Finite Element Modeling of Three-Dimensional Pulsatile Flow in the Abdominal Aorta: Relevance to Atherosclerosis Annals of Biomedical Engineering, Vol. 26, pp. 975 987, 1998 0090-6964/98 $10.50.00 Printed in the USA. All rights reserved. Copyright 1998 Biomedical Engineering Society Finite Element Modeling of Three-Dimensional

More information

4D model of hemodynamics in the abdominal aorta

4D model of hemodynamics in the abdominal aorta Bio-Medical Materials and Engineering 26 (2015) S257 S264 DOI 10.3233/BME-151312 IOS Press S257 4D model of hemodynamics in the abdominal aorta Ireneusz Zbicinski a,*, Natalia Veshkina a and Ludomir Stefa

More information

Computational analysis of effects of external carotid artery flow and occlusion on adverse carotid bifurcation hemodynamics

Computational analysis of effects of external carotid artery flow and occlusion on adverse carotid bifurcation hemodynamics Computational analysis of effects of external carotid artery flow and occlusion on adverse carotid bifurcation hemodynamics Sinjae Hyun, PhD, a Clement Kleinstreuer, PhD, b and Joseph P. Archie, Jr, PhD,

More information

EasyChair Preprint. Computational Fluid Dynamics Simulations of Flow in the Renal Arteries after Stent Graft Implantation

EasyChair Preprint. Computational Fluid Dynamics Simulations of Flow in the Renal Arteries after Stent Graft Implantation EasyChair Preprint 259 Computational Fluid Dynamics Simulations of Flow in the Renal Arteries after Stent Graft Implantation Tianyi Xia, Matthew Doyle, Thomas Forbes and Cristina H. Amon EasyChair preprints

More information

Non-invasive examination

Non-invasive examination Non-invasive examination Segmental pressure and Ankle-Brachial Index (ABI) The segmental blood pressure (SBP) examination is a simple, noninvasive method for diagnosing and localizing arterial disease.

More information

Effect of exercise on hemodynamic conditions in the abdominal aorta

Effect of exercise on hemodynamic conditions in the abdominal aorta BASIC RESEARCH PAPERS Effect of exercise on hemodynamic conditions in the abdominal aorta Charles A. Taylor, PhD, Thomas J.R. Hughes, PhD, and Christopher K. Zarins, MD, Stanford, Calif Purpose: The beneficial

More information

Numerical Simulation of Blood Flow through Asymmetric and Symmetric Occlusion in Carotid Artery

Numerical Simulation of Blood Flow through Asymmetric and Symmetric Occlusion in Carotid Artery Proceedings of the 3 rd International Conference on Fluid Flow, Heat and Mass Transfer (FFHMT 16) Ottawa, Canada May 2 3, 2016 Paper No. 170 Numerical Simulation of Blood Flow through Asymmetric and Symmetric

More information

A computational fluid dynamics simulation study of coronary blood flow affected by graft placement

A computational fluid dynamics simulation study of coronary blood flow affected by graft placement Interactive CardioVascular and Thoracic Surgery 19 (2014) 16 20 doi:10.1093/icvts/ivu034 Advance Access publication 22 April 2014 ORIGINAL ARTICLE ADULTCARDIAC A computational fluid dynamics simulation

More information

Translating In-vitro and Computational Multi-scale Models for the Vascular Surgeon

Translating In-vitro and Computational Multi-scale Models for the Vascular Surgeon Translating In-vitro and Computational Multi-scale Models for the Vascular Surgeon Benjamin A. Eslahpazir MS, BSME 1, Kyle W. Beggs 2, Zoe M. Lauters 2 Alain J. Kassab PhD 2 William M. DeCampli MD, PhD

More information

Arteriovenous Graft Modeling and Hemodynamic Interpretation

Arteriovenous Graft Modeling and Hemodynamic Interpretation Open Journal of Fluid Dynamics, 2012, 2, 324-330 http://dx.doi.org/10.4236/ojfd.2012.24a040 Published Online December 2012 (http://www.scirp.org/journal/ojfd) Arteriovenous Graft Modeling and Hemodynamic

More information

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 4, Issue 1, July 2014

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 4, Issue 1, July 2014 Mathematical Modelling and Simulation of Human Systemic Arterial System Ketan B. Naik, Dr. P H. Bhathawala Department of Applied Sciences and Humanities, Parul Institute of Engineering and Technology,

More information

EVALUATION OF ABDOMINAL AORTIC ANEURYSM WALL STESS BASED ON FLOW INDUCED LOAD

EVALUATION OF ABDOMINAL AORTIC ANEURYSM WALL STESS BASED ON FLOW INDUCED LOAD International Journal of Mechanical Engineering and Technology (IJMET) Volume 9, Issue 11, November 2018, pp. 684 688, Article ID: IJMET_09_11_068 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=9&itype=11

More information

A study of computational modeling of abdominal aortic aneurysm

A study of computational modeling of abdominal aortic aneurysm A study of computational modeling of abdominal aortic aneurysm S.M. Kim (a), M.P Lee (b), H.C Kang (c), J.H Lee (d), J.H Jeong (e), S.G Roh (f) (a) Department of Medical Bio Engineering, College of Biosystem,

More information

Numerical analysis of blood flow in human abdominal aorta

Numerical analysis of blood flow in human abdominal aorta Advances in Fluid Mechanics VI 603 Numerical analysis of blood flow in human abdominal aorta M. Podyma 1, I. Zbicinski 1, J. Walecki 2, M. L. Nowicki 2, P. Andziak 3, P. Makowski 4 & L. Stefanczyk 5 1

More information

Simulations of pulsatile blood flow in tapered S-shaped inplane and out-of-plane coronary arteries

Simulations of pulsatile blood flow in tapered S-shaped inplane and out-of-plane coronary arteries Simulations of pulsatile blood flow in tapered S-shaped inplane and out-of-plane coronary arteries Author Johnston, Barbara, Johnston, Peter Published 2009 Conference Title 18th IMACS World Congress MODSIM09

More information

DICOM Correction Item

DICOM Correction Item Correction Number DICOM Correction Item CP-449 Log Summary: Type of Modification Correct Value Name of Standard PS 3.16-2004 Rationale for Correction: Clinical applications use arterial and venous branches

More information

What is the mechanism of the audible carotid bruit? How does one calculate the velocity of blood flow?

What is the mechanism of the audible carotid bruit? How does one calculate the velocity of blood flow? CASE 8 A 65-year-old man with a history of hypertension and coronary artery disease presents to the emergency center with complaints of left-sided facial numbness and weakness. His blood pressure is normal,

More information

ISSUES ON COMPUTATIONAL MODELING FOR COMPUTATION-AIDED DIAGNOSIS 臨床診断支援ツールのための計算力学モデリング

ISSUES ON COMPUTATIONAL MODELING FOR COMPUTATION-AIDED DIAGNOSIS 臨床診断支援ツールのための計算力学モデリング ISSUES ON COMPUTATIONAL MODELING FOR COMPUTATION-AIDED DIAGNOSIS 臨床診断支援ツールのための計算力学モデリング Hao LIU Advanced Computer and Information Division, RIKEN 2-1, Hirosawa, Wako-shi, Saitama 351-0198 JAPAN e-mail:

More information

Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with and without Bypass Graft

Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with and without Bypass Graft Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with and without Bypass Graft BURASKORN NUNTADILOK 1, BENCHAWAN WIWATANAPATAPHEE 1 MEECHOKE CHUEDOUNG 1, THANONGCHAI SIRIAPISITH

More information

Steady State Computer Model of Human Vascular for Analyzing Effects of Stenosis

Steady State Computer Model of Human Vascular for Analyzing Effects of Stenosis Steady State Computer Model of Human Vascular for Analyzing Effects of Stenosis University of Illinois at Chicago Professor Andreas Linninger Michael Naskrent December 2, 2013 Table of Contents Abstract...

More information

COMPUTER SIMULATION OF BLOOD FLOW IN ARTERIES AFFECTED BY MULTIPLE ANEURYSM

COMPUTER SIMULATION OF BLOOD FLOW IN ARTERIES AFFECTED BY MULTIPLE ANEURYSM COMPUTER SIMULATION OF BLOOD FLOW IN ARTERIES AFFECTED BY MULTIPLE ANEURYSM H. GIRIJA BAI 1 and K.B. NAIDU 2 Department of Mathematics, Sathyabama University, Chennai-600 119, Tamil Nadu, India 1 girijanameprakash@gmail.com

More information

Contents 1 Computational Haemodynamics An Introduction 2 The Human Cardiovascular System

Contents 1 Computational Haemodynamics An Introduction 2 The Human Cardiovascular System Contents 1 Computational Haemodynamics An Introduction... 1 1.1 What is Computational Haemodynamics (CHD)... 1 1.2 Advantages of CHD... 3 1.3 Applications in the Cardiovascular System... 4 1.3.1 CHD as

More information

Using Computational Fluid Dynamics Model to Predict Changes in Velocity properties in Stented Carotid Artery

Using Computational Fluid Dynamics Model to Predict Changes in Velocity properties in Stented Carotid Artery Excerpt from the Proceedings of the COMSOL Conference 2010 Paris (COMSOL Conference) Using Computational Fluid Dynamics Model to Predict Changes in Velocity properties in Stented Carotid Artery Vaidehi

More information

Marquette University Sung Kwon Marquette University Recommended Citation

Marquette University Sung Kwon Marquette University Recommended Citation Marquette University e-publications@marquette Master's Theses (2009 -) Dissertations, Theses, and Professional Projects Quantification of Local Hemodynamic Alterations Caused by Virtual Implantation of

More information

Physician s Vascular Interpretation Examination Content Outline

Physician s Vascular Interpretation Examination Content Outline Physician s Vascular Interpretation Examination Content Outline (Outline Summary) # Domain Subdomain Percentage 1 2 3 4 5 6 Cerebrovascular Abdominal Peripheral Arterial - Duplex Imaging Peripheral Arterial

More information

Effects of Non-Newtonian Behavior of Blood on Wall Shear Stress in an Elastic Vessel with Simple and Consecutive Stenosis

Effects of Non-Newtonian Behavior of Blood on Wall Shear Stress in an Elastic Vessel with Simple and Consecutive Stenosis Biomedical & Pharmacology Journal Vol. 8(1), 123-131 (2015) Effects of Non-Newtonian Behavior of Blood on Wall Shear Stress in an Elastic Vessel with Simple and Consecutive Stenosis M. JAHANGIRI 1 *, M.

More information

Blood flow in vessels with artificial or pathological geometrical changes

Blood flow in vessels with artificial or pathological geometrical changes Blood flow in vessels with artificial or pathological geometrical changes P. Tibaut 1, B. Wiesler 1, M. Mayer 2 & R. Wegenkittel 3 1 AVL LIST GmbH, Graz, Austria 2 VRVIs, Vienna, Austria 3 Tiani Medgraph

More information

HD Scanning: Velocities and Volume Flow

HD Scanning: Velocities and Volume Flow HD Scanning: Velocities and Volume Flow Non-Invasive Lab Symposium West Orange, NJ April 27, 2018 Volume Flow Cindy Sturt, MD, FACS, RVT 500,000 Americans on dialysis 20-25% annual mortality 65% 5 year

More information

What Do We Know? Disclosure Statement: 3/11/2015. Deep abdominal imaging

What Do We Know? Disclosure Statement: 3/11/2015. Deep abdominal imaging Marsha M. Neumyer, BS, RVT, FSVU, FSDMS, FAIUM International Director Vascular Diagnostic Educational Services Vascular Resource Associates Harrisburg, PA Disclosure Statement: CME Calendar QR Code Marsha

More information

Image Formation (10) 2 Evaluation and Selection of Representative Images (10)

Image Formation (10) 2 Evaluation and Selection of Representative Images (10) STRUCTURED SELF ASSESSMENT CONTENT SPECIFICATIONS SSA LAUNCH DATE: JANUARY 1, 2018 Vascular Sonography The purpose of continuing qualifications requirements (CQR) is to assist registered technologists

More information

CFD Study of the Blood Flow in Cerebral Aneurysms Treated with Flow Diverter Stents

CFD Study of the Blood Flow in Cerebral Aneurysms Treated with Flow Diverter Stents CFD Study of the Blood Flow in Cerebral Aneurysms Treated with Flow Diverter Stents Augusto F. Sanches and Eva Gutheil Interdisciplinary Center for Scientific Computing, Heidelberg University Flow diverters

More information

A Multiphysics Simulation of a Healthy and a Diseased Abdominal Aorta

A Multiphysics Simulation of a Healthy and a Diseased Abdominal Aorta A Multiphysics Simulation of a Healthy and a Diseased Abdominal Aorta No Author Given No Institute Given Abstract. Abdominal Aortic Aneurysm is a potentially life-threatening disease if not treated adequately.

More information

Research Article Hemodynamic Features in Stenosed Coronary Arteries: CFD Analysis Based on Histological Images

Research Article Hemodynamic Features in Stenosed Coronary Arteries: CFD Analysis Based on Histological Images Applied Mathematics Volume, Article ID 77, pages http://dx.doi.org/.//77 Research Article Hemodynamic Features in Stenosed Coronary Arteries: CFD Analysis Based on Histological Images Mahsa Dabagh,, Wakako

More information

History of Vascular Modelling. William Harvey discovery of the circulation 1628

History of Vascular Modelling. William Harvey discovery of the circulation 1628 History of Vascular Modelling William Harvey discovery of the circulation 1628 William Harvey (1578-1657) Since all things, both argument and ocular demonstration, show that the blood passes through the

More information

Studying the Flow Dynamics Within Endografts in Abdominal Aortic Aneurysms

Studying the Flow Dynamics Within Endografts in Abdominal Aortic Aneurysms Chapter 8 Studying the Flow Dynamics Within Endografts in Abdominal Aortic Aneurysms Efstratios Georgakarakos, Antonios Xenakis, George S. Georgiadis, Konstantinos C. Kapoulas, Evagelos Nikolopoulos and

More information

Subclavian artery Stenting

Subclavian artery Stenting Subclavian artery Stenting Etiology Atherosclerosis Takayasu s arteritis Fibromuscular dysplasia Giant Cell Arteritis Radiation-induced Vascular Injury Thoracic Outlet Syndrome Neurofibromatosis Incidence

More information

Vascular Sonography Examination

Vascular Sonography Examination Vascular Sonography Examination The purpose of The American Registry of Radiologic Technologists (ARRT ) Vascular Sonography Examination is to assess the knowledge and cognitive skills underlying the intelligent

More information

Simulations of the blood flow in the arterio-venous fistula for haemodialysis

Simulations of the blood flow in the arterio-venous fistula for haemodialysis Acta of Bioengineering and Biomechanics Vol. 16, No. 1, 2014 Original paper DOI: 10.5277/abb140109 Simulations of the blood flow in the arterio-venous fistula for haemodialysis DANIEL JODKO*, DAMIAN OBIDOWSKI,

More information

Computational medical imaging and hemodynamics framework for functional analysis and assessment of cardiovascular structures

Computational medical imaging and hemodynamics framework for functional analysis and assessment of cardiovascular structures DOI 10.1186/s12938-017-0326-y BioMedical Engineering OnLine REVIEW Open Access Computational medical imaging and hemodynamics framework for functional analysis and assessment of cardiovascular structures

More information

STRUCTURED EDUCATION REQUIREMENTS IMPLEMENTATION DATE: JULY 1, 2016

STRUCTURED EDUCATION REQUIREMENTS IMPLEMENTATION DATE: JULY 1, 2016 STRUCTURED EDUCATION REQUIREMENTS Vascular Sonography The purpose of structured education is to provide the opportunity for individuals to develop mastery of discipline-specific knowledge that, when coupled

More information

Open fenestration for complicated acute aortic B dissection

Open fenestration for complicated acute aortic B dissection Art of Operative Techniques Open fenestration for complicated acute aortic B dissection Santi Trimarchi 1, Sara Segreti 1, Viviana Grassi 1, Chiara Lomazzi 1, Marta Cova 1, Gabriele Piffaretti 2, Vincenzo

More information

Computational Simulations Demonstrate Altered Wall Shear Stress in Aortic Coarctation Patients Treated by Resection with End-to-end Anastomosis

Computational Simulations Demonstrate Altered Wall Shear Stress in Aortic Coarctation Patients Treated by Resection with End-to-end Anastomosis 432 Computational Simulations Demonstrate Altered Wall Shear Stress in Aortic Coarctation Patients Treated by Resection with End-to-end Anastomosischd_553 432..443 John F. Jr. LaDisa, PhD,*,, Ronak J.

More information

Tibial artery stenosis icd 10

Tibial artery stenosis icd 10 Search Search Tibial artery stenosis icd 10 Free, official information about 2012 (and also 2013-2015) ICD -9-CM diagnosis code 998.89, including coding notes, detailed descriptions, index cross-references

More information

On the relationship between competitive flow and FFT analysis of the flow waves in the left internal mammary artery graft in the process of CABG

On the relationship between competitive flow and FFT analysis of the flow waves in the left internal mammary artery graft in the process of CABG DOI 10.1186/s12938-016-0260-4 BioMedical Engineering OnLine RESEARCH Open Access On the relationship between competitive flow and FFT analysis of the flow waves in the left internal mammary artery graft

More information

Design and Simulation of Blocked Blood Vessel for Early Detection of Heart Diseases

Design and Simulation of Blocked Blood Vessel for Early Detection of Heart Diseases Proceedings of the 215 2nd International Symposium on Physics and Technology of Sensors, 8-1th March, 215, Pune, India Design and Simulation of Blocked Blood Vessel for Early Detection of Heart Diseases

More information

Case Report 1. CTA head. (c) Tele3D Advantage, LLC

Case Report 1. CTA head. (c) Tele3D Advantage, LLC Case Report 1 CTA head 1 History 82 YEAR OLD woman with signs and symptoms of increased intra cranial pressure in setting of SAH. CT Brain was performed followed by CT Angiography of head. 2 CT brain Extensive

More information

JADAVPUR UNIVERSITY & 2 SCHOOL OF BIOSCIENCE AND ENGINEERING ABHIRUP ROY CHOUDHURY 1, KRITTIKA DASGUPTA 2, ABHIJIT CHANDA 1,2, DEBABRATA NAG 1

JADAVPUR UNIVERSITY & 2 SCHOOL OF BIOSCIENCE AND ENGINEERING ABHIRUP ROY CHOUDHURY 1, KRITTIKA DASGUPTA 2, ABHIJIT CHANDA 1,2, DEBABRATA NAG 1 Presented at the COMSOL Conference 2010 India ABHIRUP ROY CHOUDHURY 1, KRITTIKA DASGUPTA 2, ABHIJIT CHANDA 1,2, DEBABRATA NAG 1 1 DEPARTMENT OF MECHANICAL ENGINEERING & 2 SCHOOL OF BIOSCIENCE AND ENGINEERING

More information

BLOOD FLOW VISUALISATION THROUGH CAROTID BIFURCATION USING ANSYS CFD

BLOOD FLOW VISUALISATION THROUGH CAROTID BIFURCATION USING ANSYS CFD BLOOD FLOW VISUALISATION THROUGH CAROTID BIFURCATION USING ANSYS CFD Roopa.V.Chanashetty 1, Dr.Channappa Bhyri 2 and Vijaykumar Chanashetty 3 1 Department of Electronics and Communication Engineering,

More information

Learning Objectives for Rotations in Vascular Surgery Year 3 Basic Clerkship

Learning Objectives for Rotations in Vascular Surgery Year 3 Basic Clerkship Learning Objectives for Rotations in Vascular Surgery Year 3 Basic Clerkship CLINICAL PROBLEMS IN VASCULAR SURGERY 1. ABDOMINAL AORTIC ANEURYSM A 70 year old man presents in the emergency department with

More information

1Pulse sequences for non CE MRA

1Pulse sequences for non CE MRA MRI: Principles and Applications, Friday, 8.30 9.20 am Pulse sequences for non CE MRA S. I. Gonçalves, PhD Radiology Department University Hospital Coimbra Autumn Semester, 2011 1 Magnetic resonance angiography

More information

BILLING BULLETIN. Re: Interventional Cardiology. Bulletin #: 1. Date Issued: November 10, Background

BILLING BULLETIN. Re: Interventional Cardiology. Bulletin #: 1. Date Issued: November 10, Background BILLING BULLETIN Re: Interventional Cardiology Bulletin #: 1 Date Issued: November 10, 2016 Background This Billing Bulletin provides billing guidance when submitting claims to Manitoba Health, Seniors

More information

Duplex Ultrasound of the Renal Arteries. Duplex Ultrasound. In the Beginning

Duplex Ultrasound of the Renal Arteries. Duplex Ultrasound. In the Beginning Duplex Ultrasound of the Renal Arteries DIMENSIONS IN HEART AND VASCULAR CARE 2013 PENN STATE HEART AND VASCULAR INSTITUTE ROBERT G. ATNIP MD PROFESSOR OF SURGERY AND RADIOLOGY Duplex Ultrasound Developed

More information

UNIVERSITY OF CINCINNATI

UNIVERSITY OF CINCINNATI UNIVERSITY OF CINCINNATI Date: 5-Nov-2010 I, Justin Niehaus, hereby submit this original work as part of the requirements for the degree of: Master of Science in Aerospace Engineering It is entitled: Use

More information

Imaging for Peripheral Vascular Disease

Imaging for Peripheral Vascular Disease Imaging for Peripheral Vascular Disease James G. Jollis, MD Director, Rex Hospital Cardiovascular Imaging Imaging for Peripheral Vascular Disease 54 year old male with exertional calf pain in his right

More information

PHYSIOLOGICAL PULSATILE WAVEFORM THROUGH AXISYMMETRIC STENOSED ARTERIES: NUMERICAL SIMULATION

PHYSIOLOGICAL PULSATILE WAVEFORM THROUGH AXISYMMETRIC STENOSED ARTERIES: NUMERICAL SIMULATION PHYSIOLOGICAL PULSATILE WAVEFORM THROUGH AXISYMMETRIC STENOSED ARTERIES: NUMERICAL SIMULATION Jayme Pinto Ortiz University of São Paulo - Avenida Prof. Luciano Gualberto, travessa3 nº 380 - CEP - 05508-900

More information

Is a Flat Inlet Profile Sufficient for WSS Estimation in the Aortic Arch?

Is a Flat Inlet Profile Sufficient for WSS Estimation in the Aortic Arch? Is a Flat Inlet Profile Sufficient for WSS Estimation in the Aortic Arch? J. Renner 1, D. Loyd 1, T. Länne 2, M. Karlsson 1 1 Department of Management and Engineering 2 Department of Medical and Health

More information

Visualization and Quantification of Blood Flow in the Human Aorta. From in vivo 4D Phase Contrast MRI to Subject-Specific Computational Hemodynamics

Visualization and Quantification of Blood Flow in the Human Aorta. From in vivo 4D Phase Contrast MRI to Subject-Specific Computational Hemodynamics Visualization and Quantification of Blood Flow in the Human Aorta. From in vivo 4D Phase Contrast MRI to Subject-Specific Computational Hemodynamics Industrial Bioengineering Group Department of Mechanics,

More information

Breathing. Heart Rate

Breathing. Heart Rate Breathing Heart Rate Inspiration Expiration (Pressos not Stretched) Heart Rate increases with inspiration (Pressos Stretched) Heart Rate decreases with expiration Upside Down (Pressos Stretched) HR Decreases

More information

Simulation of Aorta Artery Aneurysms Using Active Electronic Circuit

Simulation of Aorta Artery Aneurysms Using Active Electronic Circuit American Journal of Applied Sciences 4 (4): 03-0, 007 ISSN 546-939 007 Science Publications Simulation of Aorta Artery Aneurysms Using Active Electronic Circuit Kamran Hassani, Mahdi Navidbakhsh and 3

More information

Vascular Technology Examination Content Outline

Vascular Technology Examination Content Outline Vascular Technology Examination Content Outline (Outline Summary) # Domain Subdomain Percentage 1 Normal Anatomy, Perfusion, and Function Evaluate normal anatomy, perfusion, function 2 Pathology, Perfusion,

More information

Peripheral Vascular Disease

Peripheral Vascular Disease Peripheral artery disease (PAD) results from the buildup of plaque (atherosclerosis) in the arteries of the legs. For people with PAD, symptoms may be mild, requiring no treatment except modification of

More information

Predicting flow in aortic dissection: comparison of computational model with PC-MRI velocity measurements

Predicting flow in aortic dissection: comparison of computational model with PC-MRI velocity measurements Predicting flow in aortic dissection: comparison of computational model with PC-MRI velocity measurements Z. Cheng 1, C. Juli 3 N.B. Wood 1, R.G.J. Gibbs 2, X.Y. Xu 1 1 Department of Chemical Engineering,

More information

CLINICAL PRESENTATION AND RADIOLOGY QUIZ QUESTION

CLINICAL PRESENTATION AND RADIOLOGY QUIZ QUESTION Donald L. Renfrew, MD Radiology Associates of the Fox Valley, 333 N. Commercial Street, Suite 100, Neenah, WI 54956 6/30/2012 Radiology Quiz of the Week # 79 Page 1 CLINICAL PRESENTATION AND RADIOLOGY

More information

Computational Fluid Dynamics Analysis of Blood Flow in Human Aorta

Computational Fluid Dynamics Analysis of Blood Flow in Human Aorta Computational Fluid Dynamics Analysis of Blood Flow in Human Aorta Yogesh V. Borse 1, Prof. S.A. Giri 2 M. Tech Scholar, Dept of Mechanical Engg, Ramdeobaba College of Engineering and Management, Nagpur,

More information

Acute Type B dissection. Closure of the infra diaphragmatic tear: how and when?

Acute Type B dissection. Closure of the infra diaphragmatic tear: how and when? Acute Type B dissection. Closure of the infra diaphragmatic tear: how and when? Prof. Olgierd Rowiński II Department of Clinical Radiology Medical University of Warsaw Disclosure Speaker name: Olgierd

More information

Chapter 05 Cardiovascular System

Chapter 05 Cardiovascular System Chapter 05 Cardiovascular System 1 Cardiovascular System: Heart and Blood Vessels 2 Points to ponder What are the functions of the cardiovascular system? What is the anatomy of the heart? Of blood vessels,

More information

2015 ARDMS Physicians Vascular Interpretation Job Task Analysis Summary Report

2015 ARDMS Physicians Vascular Interpretation Job Task Analysis Summary Report P a g e 1 2015 ARDMS Physicians Vascular Interpretation Job Task Analysis Summary Report American Registry for Diagnostic Medical Sonography (ARDMS) P a g e 2 Table of Contents ABOUT THE REPORT... 3 METHODOLOGY...

More information

Identification of Atherosclerotic Lesion-Prone Sites through Patient-Specific Simulation of Low-Density Lipoprotein Accumulation

Identification of Atherosclerotic Lesion-Prone Sites through Patient-Specific Simulation of Low-Density Lipoprotein Accumulation Identification of Atherosclerotic Lesion-Prone Sites through Patient-Specific Simulation of Low-Density Lipoprotein Accumulation Ufuk Olgac 1, Vartan Kurtcuoglu 1, Stefan C. Saur 2, and Dimos Poulikakos

More information

THE VESSELS OF BLOOD CIRCULATION

THE VESSELS OF BLOOD CIRCULATION THE VESSELS OF BLOOD CIRCULATION scientistcindy.com /the-vessels-of-blood-circulation.html NOTE: You should familiarize yourself with the anatomy of the heart and have a good understanding of the flow

More information

The anterior communicating artery (AcomA) is a recognized

The anterior communicating artery (AcomA) is a recognized ORIGINAL RESEARCH M.A. Castro C.M. Putman M.J. Sheridan J.R. Cebral Hemodynamic Patterns of Anterior Communicating Artery Aneurysms: A Possible Association with Rupture BACKGROUND AND PURPOSE: The anterior

More information

54. Simulation and research on the influence of the shape and the geometrical parameters of a blood vessel bypass graft upon hemodynamics

54. Simulation and research on the influence of the shape and the geometrical parameters of a blood vessel bypass graft upon hemodynamics 54. Simulation and research on the influence of the shape and the geometrical parameters of a blood vessel bypass graft upon hemodynamics Andžela Šešok 1, Donatas Lukšys 2 Vilnius Gediminas Technical University,

More information

Edinburgh Imaging Academy online distance learning courses

Edinburgh Imaging Academy online distance learning courses Course: Biomechanics Semester 1 / Autumn 10 Credits Each Course is composed of Modules & Activities. Modules: Biomechanics basics Ultrasound advanced Cardiovascular IMSc IMSc IMSc Each Module is composed

More information

Effects of Renin-Angiotensin System blockade on arterial stiffness and function. Gérard M. LONDON Manhès Hospital Paris, France

Effects of Renin-Angiotensin System blockade on arterial stiffness and function. Gérard M. LONDON Manhès Hospital Paris, France Effects of Renin-Angiotensin System blockade on arterial stiffness and function Gérard M. LONDON Manhès Hospital Paris, France Determinants of vascular overload (afterload) on the heart Peripheral Resistance

More information

Recommendations for Follow-up After Vascular Surgery Arterial Procedures SVS Practice Guidelines

Recommendations for Follow-up After Vascular Surgery Arterial Procedures SVS Practice Guidelines Recommendations for Follow-up After Vascular Surgery Arterial Procedures 2018 SVS Practice Guidelines vsweb.org/svsguidelines About the guidelines Published in the July 2018 issue of Journal of Vascular

More information

Figure ) The specific chamber of the heart that is indicated by letter A is called the. Diff: 1 Page Ref: 364

Figure ) The specific chamber of the heart that is indicated by letter A is called the. Diff: 1 Page Ref: 364 Essentials of Anatomy and Physiology, 9e (Marieb) Chapter 11 The Cardiovascular System Short Answer Figure 11.1 Using Figure 11.1, identify the following: 1) The Purkinje fibers are indicated by label.

More information

An Experimental Computational Study of Catheter Induced Alterations in Pulse Wave Velocity in Anesthetized Mice

An Experimental Computational Study of Catheter Induced Alterations in Pulse Wave Velocity in Anesthetized Mice An Experimental Computational Study of Catheter Induced Alterations in Pulse Wave Velocity in Anesthetized Mice Federica Cuomo, Jacopo Ferruzzi, Jay D. Humphrey & C. Alberto Figueroa Annals of Biomedical

More information

Introduction History Preceded by Arterial Doppler and ABI Indications

Introduction History Preceded by Arterial Doppler and ABI Indications Elise Brady, RVT, RDMS Introduction History Preceded by Arterial Doppler and ABI Indications 1) Abnormal ABI (within 2weeks of duplex) 2) Abnormal Doppler waveforms 3) Claudication 4) History of PVD 5)

More information

Computational design of Intracranial Stent using 3D visualization system

Computational design of Intracranial Stent using 3D visualization system Computational design of Intracranial Stent using 3D visualization system Institute of Fluid Science, Tohoku University Makoto OHTA Graduate school of Engineering Hitomi Anzai Graduate school of Biomedical

More information

Appendix II: ECHOCARDIOGRAPHY ANALYSIS

Appendix II: ECHOCARDIOGRAPHY ANALYSIS Appendix II: ECHOCARDIOGRAPHY ANALYSIS Two-Dimensional (2D) imaging was performed using the Vivid 7 Advantage cardiovascular ultrasound system (GE Medical Systems, Milwaukee) with a frame rate of 400 frames

More information

Lower Extremity Artery: Physiologic Testing

Lower Extremity Artery: Physiologic Testing Master Title Ultrasound for Initial Evaluation of Lower Extremity Arterial Occlusive Disease: WHY? Gregory L. Moneta MD Professor and Chief Knight Cardiovascular Institute Division of Vascular Surgery

More information

The Cardiovascular System

The Cardiovascular System PowerPoint Lecture Slide Presentation by Patty Bostwick-Taylor, Florence-Darlington Technical College The Cardiovascular System 11PART B The Heart: Cardiac Output Cardiac output (CO) Amount of blood pumped

More information

Hematocrit Level on Blood flow through a Stenosed Artery with Permeable Wall: A Theoretical Study

Hematocrit Level on Blood flow through a Stenosed Artery with Permeable Wall: A Theoretical Study Available at http://pvamu.edu/aam Appl. Appl. Math. ISSN: 1932-9466 Vol. 12, Issue 1 (June 2017), pp. 291-304 Applications and Applied Mathematics: An International Journal (AAM) Hematocrit Level on Blood

More information

Late False Lumen Expansion Predicted by Preoperative Blood Flow Simulation in a Patient with Chronic Type B Aortic Dissection

Late False Lumen Expansion Predicted by Preoperative Blood Flow Simulation in a Patient with Chronic Type B Aortic Dissection Accepted Manuscript Late False Lumen Expansion Predicted by Preoperative Blood Flow Simulation in a Patient with Chronic Type B Aortic Dissection Chikara Ueki, MD, Hiroshi Tsuneyoshi, MD, PhD PII: S0022-5223(18)32652-7

More information

Abdominal Exam: The examination of the abdomen used by physicians to detect an abdominal aortic aneurysm.

Abdominal Exam: The examination of the abdomen used by physicians to detect an abdominal aortic aneurysm. Glossary of Terms Abdominal Exam: The examination of the abdomen used by physicians to detect an abdominal aortic aneurysm. Angiogram: A diagnostic test requiring the insertion of a catheter into an artery

More information

Validation of a computational model versus a bench top model of an aortic dissection model

Validation of a computational model versus a bench top model of an aortic dissection model ORIGINAL ARTICLES Validation of a computational model versus a bench top model of an aortic dissection model Khalil Khanafer 1, 2, Marty S. Schlicht 2, Kambiz Vafai 3, Saurabh Prabhaar 4, Mohamed Gaith

More information

V.A. is a 62-year-old male who presents in referral

V.A. is a 62-year-old male who presents in referral , LLC an HMP Communications Holdings Company Clinical Case Update Latest Trends in Critical Limb Ischemia Imaging Amit Srivastava, MD, FACC, FABVM Interventional Cardiologist Bay Area Heart Center St.

More information

ARTICLE IN PRESS Medical Engineering & Physics xxx (2012) xxx xxx

ARTICLE IN PRESS Medical Engineering & Physics xxx (2012) xxx xxx Medical Engineering & Physics xxx (2012) xxx xxx Contents lists available at SciVerse ScienceDirect Medical Engineering & Physics jou rnal h omepa g e: www.elsevier.com/locate/medengphy Including aortic

More information

Case 9799 Stanford type A aortic dissection: US and CT findings

Case 9799 Stanford type A aortic dissection: US and CT findings Case 9799 Stanford type A aortic dissection: US and CT findings Accogli S, Aringhieri G, Scalise P, Angelini G, Pancrazi F, Bemi P, Bartolozzi C Department of Diagnostic and Interventional Radiology, University

More information