Predicting flow in aortic dissection: comparison of computational model with PC-MRI velocity measurements

Size: px
Start display at page:

Download "Predicting flow in aortic dissection: comparison of computational model with PC-MRI velocity measurements"

Transcription

1 Predicting flow in aortic dissection: comparison of computational model with PC-MRI velocity measurements Z. Cheng 1, C. Juli 3 N.B. Wood 1, R.G.J. Gibbs 2, X.Y. Xu 1 1 Department of Chemical Engineering, Imperial College London, South Kensington Campus, London SW7 2AZ, UK 2 Imperial Vascular Unit, St Mary s Hospital, Imperial College Healthcare NHS Trust, London W2 1NY, UK 3 Department of Radiology, St Mary s Hospital, Imperial College Healthcare NHS Trust, London W2 1NY, UK Abstract Aortic dissection is a life threatening process in which the weakened wall develops a tear, causing separation of wall layers. The dissected layers separate the original true aortic lumen and a newly created false lumen. If untreated, the condition can be fatal. Flow rate in the false lumen is a key feature for false lumen patency, which has been regarded as one of the most important predictors of adverse early and later outcomes. Detailed flow analysis in the dissected aorta may assist vascular surgeons in making treatment decisions, but computational models to simulate flow in aortic dissections often involve several assumptions. The purpose of this study is to assess the computational models adopted in previous studies by comparison with in vivo velocity data obtained by means of phase contrast magnetic resonance imaging (PC- MRI). Aortic dissection geometry was reconstructed from computed tomography (CT) images, while PC-MRI velocity data were used to define inflow conditions and to provide distal velocity components for comparison with the simulation results. The 1

2 computational fluid dynamics (CFD) simulation incorporated a laminar-turbulent transition model, which is necessary for adequate flow simulation in aortic conditions. Velocity contours from PC-MRI and CFD in the two lumens at the distal plane were compared at four representative time points in the pulse cycle. The computational model successfully captured the complex regions of flow reversal and recirculation qualitatively, although quantitative differences exist. With a rigid wall assumption and exclusion of arch branches, the CFD model over-predicted the false lumen flow rate by 25% at peak systole. Nevertheless, an overall good agreement was achieved, confirming the physiological relevance and validity of the computational model for type B aortic dissection with a relatively stiff dissection flap. Keywords: Aortic dissection, computational fluid dynamics, magnetic resonance velocity imaging 1. Introduction Aortic dissection is a life threatening process in which a tear in the aortic wall allows blood to track within the wall, separating its component layers. The dissected layers (dissection lamellae or flap) separate the original true aortic lumen and a newly created false lumen. The anatomical position of the entry tear is used to define Type A dissection (starting in the ascending aorta) and Type B dissection (starting in the distal aortic arch). Type A dissection normally requires immediate surgery, whereas for Type B the decision for medical treatment or surgical intervention depends upon the clinical presentation. In these cases, detailed analysis of flow patterns in the dissection aorta can provide useful information for clinical decision making. 2

3 The development of high-resolution medical imaging and robust image processing techniques has promoted image-based computational fluid dynamics (CFD) modelling of in vivo hemodynamics [1]. A number of studies have been carried out to investigate the flow patterns and hemodynamic environment in dissected aorta. Karmonik et al. [2] examined changes in anatomy as well as pressure and wall shear stress in an aortic dissection case with aneurysmal dilatation. In a longitudinal study, Tse et al. [3] investigated variations of certain hemodynamic parameters in the development of a dissecting aneurismal aorta. In our previous studies, an advanced transitional turbulence model was employed to investigate the complex flow patterns and detailed hemodynamic environment in multiple cases of type B dissection [4, 5]. Results were analysed in each case and compared between different groups. One of the most important findings was that flow rate into the false lumen was strongly correlated with the primary entry tear size. Since false lumen patency is a key predictor of adverse early and later outcomes [6], false lumen flow rate (or entry tear size) may be an important parameter for risk stratification of dissection patients. However, computational models for the analysis of flow in aortic dissections (e.g. [2-5]) often involve several assumptions, including compensated exclusion of the aortic arch branches, flat velocity profile at the inlet, and rigid walls accompanied by fixed, constant distal outflow pressures. The purpose of this study is to assess the computational models adopted in our previous studies by comparison with in vivo velocity data obtained by means of phase contrast magnetic resonance imaging (PC- MRI). Computed tomography (CT) is the standard imaging modality for diagnostic imaging of aortic dissection, but for flow simulations, 4D ciné PC-MRI would be desirable to provide patient-specific flow boundary conditions [7]. PC-MRI flow imaging is considered the only imaging technique that can provide measurement of blood 3

4 velocities in vivo with good resolution both spatially and temporally. In this study, a typical type B aortic dissection case was analysed by using the same computational model design and numerical analysis methods as adopted in our previous studies [4, 5]. This case was chosen for its comprehensive set of PC-MRI data which provided not only the necessary boundary conditions but also additional data required for validation. 2. Methods 2.1 Medical image processing and geometry reconstruction Anatomical information was extracted from CT scan of a patient (male, age 56) diagnosed with a typical type B aortic dissection. Subsequently, PC-MRI data was acquired for further examination. The study complied with the Declaration of Helsinki and was approved by the local Research Ethics Committee. The patient gave written, informed consent. The model geometry was based on the initial CT images covering the entire aorta (approximately 300 slices, 2 mm thick, spacing 1 mm; pixel resolution 0.86 mm), as shown in Figure 1(a). The proximal entry tear can be seen clearly in the transparent image (Figure 1(b)). Anatomical MR images had relatively low axial resolution, and were only used for registration and localization of imaging planes between the CT and PC-MRI data. The CT images were imported into an image processing package Mimics (Materialise HQ, Louvain, Belgium) and the geometry of the dissected aorta was reconstructed from the contours of the segmented lumen area from the serial CT slices and was smoothed accordingly before meshing. PC-MRI was performed at three planes in the aortic dissection (Figure 1(b)), providing sufficient data for inlet boundary condition and validation (TE 2.6 ms, TR 4

5 4.7 ms, flip Angle 15 degrees, pixel spacing mm, slice thickness 8 mm). At the imaging planes 1 and 3, encoding velocity (V enc ) was 200 mm/s for IS (inferiorsuperior) direction and 100 mm/s for AP (anterior posterior) and RL (right left) directions. At imaging plane 2, V enc was 200 mm/s for AP direction, and 100 mm/s for the other two directions. Plane 1 was located in the proximal ascending aorta in order to obtain velocity profiles distal to the aortic valve. Plane 2 was in the aortic arch between the root of the left subclavian artery and the site of proximal entry tear. Since the tear occurred very close to the left subclavian artery, there was limited space to fit plane 2 between the artery and the entry tear. Flow imaging at plane 2 was required to determine the amount of flow distal to the arch branches, and velocity profiles proximal to the tear. Plane 3 was in the mid-thoracic descending aorta distal to the proximal entry tear, at the level of pulmonary bifurcation, covering both the true and false lumen. The PC-MRI data from this plane were used to compare with those from the computational simulation for model validation. Images acquired with PC-MRI were processed by using an in-house programme. The region of interest was segmented from magnitude images and then mapped on to the corresponding phase images; the grayscale of the pixels inside the region of interest was converted to velocity information according to the applied encoding sequence of the scanner (Philips Medical Systems). For imaging planes 1 and 2, the flow rate through each plane was calculated based on the converted velocity and pixel size; this was utilized as boundary conditions for the flow model described in the next section. The PC-MRI data acquired at plane 3 were processed in the same way, and 2D velocity contours of the true and false lumen were plotted for the purpose of comparison with the simulation results. The computational model (Figure 1(c)) shows the inlet at imaging plane 1. To keep the approach consistent with previous patient specific studies, the model was 5

6 simplified by excluding the three branches in the aortic arch and other small branches in the descending aorta, whilst matching the flow at planes 1 and 2 to provide the correct amount of flow through planes 2 and 3. The false lumen propagated down the lateral side of the thoracic descending aorta, before spiralling around the true lumen toward its anterior side at the mid-descending aorta. It continued to twist to the rightposterior side of the aorta, then to the lateral side in the distal segment of the abdominal aorta. As it extended to the left iliac artery below the abdominal bifurcation, two adjacent outlets (one for each lumen) were included in the model, both located in the abdominal aorta far distal to the imaging plane 3 (Figure 1(c)). The length of the descending aorta was approximately 381 mm. The proximal entry tear was about 22 mm in width and 25 mm in height, and only 0.4 mm below the top of the aortic arch. The false lumen was prevented from propagating proximally by the left subclavian artery. No distal tears could be identified. 2.2 Flow simulation and boundary conditions Simulations were carried out with ANSYS CFX 12, and the γ-θ correlation-based laminar-turbulent transition model ( SST Tran ) was adopted [8], as described previously [4]. Blood was assumed to be Newtonian with viscosity 4.0 mpa s and density 1060 kg/m 3. The aortic walls were assumed to be rigid with no slip. Flow boundary conditions were extracted from the PC-MRI velocity images. The flow data at each imaging plane were recorded at 29 time points along a cardiac cycle of 0.98 s duration. The flow rate waveforms at imaging plane 1 (ascending aorta root) and imaging plane 2 (aortic arch after the branches) are presented in Figure 2. The peak systolic flow rate was 446 cm 3 /s in the ascending aorta, and 370 cm 3 /s in the distal aortic arch. Hence, the flow exiting through the three main branches on the arch 6

7 at peak systole was 76 cm 3 /s, which was 17% of the peak flow rate from the heart. This ratio is close to the value (15%) assumed previously [4, 5]. The flow waveform derived from imaging plane 2 was specified at the model inlet in the ascending aorta with a flat through plane profile, as adopted in previous patientspecific studies. Based on the inlet area, the mean and maximum Reynolds numbers were 850 and 3512 respectively, and the Womersley parameter was A low inlet turbulence level of 1.5% was chosen to represent initial disturbances in the flow and allow true transition to occur realistically. At the model outlets, zero relative static pressure was applied across both surfaces. A uniform time step of 0.001s was used. All simulations were carried out for three cardiac cycles to achieve a periodic solution, and the results of the last cycle were used for comparison. 2.3 Mesh sensitivity test The reconstructed model was imported into ANSYS ICEM CFX for mesh generation. Unstructured mesh consisting of 3D tetrahedral cells combined with prismatic cells near the wall was created. A very fine near wall resolution in the tear region was ensured by using a minimum of ten layers of prismatic cells at the wall, height of wall cells in wall units (y+) < 2, together with local refinement. Mesh independence tests were carried out with an initial mesh consisting of 2,600,000 elements, and finer meshes with increased number of prismatic wall elements. The results in terms of maximum time-averaged wall shear stress (WSS) and turbulence kinetic energy were compared between different meshes. The differences in these parameters were less than 4% between the initial 2,600,000 elements mesh and the 3,200,000 elements mesh, and less than 3.5% between the 3,200,000 elements mesh and the 4,700,000 elements mesh. Hence, the mesh of 3,200,000 elements was deemed to be sufficient. 7

8 2.4 Analysis of simulation results The simulation results were analysed using ANSYS CFX-Post 12. For the purpose of comparison, velocities are displayed by plotting colour-coded contours at the crosssectional plane corresponding to imaging plane 3 where PC-MRI data were acquired. Instantaneous streamlines are presented at different time points for better visualisation of time-varying flow patterns. In order to examine the turbulence level in the model, turbulence intensity (Tu) was evaluated, which is defined as: (1) where is the turbulence kinetic energy and is the instantaneous local velocity. The iso-surface of Tu is presented to indicate the corresponding turbulence zone with specified value at the systolic mid-deceleration phase, when Tu is usually at its highest value. 3. Results 3.1 Flow distribution in the true and false lumen As reported by Cheng et al. [5], the flow division between the two lumens was strongly dependent on the size and location of the proximal entry tear. Figure 3 shows the comparison of time varying flow rate at the location of imaging plane 3 obtained from the CFD simulation and the corresponding PC-MRI data. Based on the simulation results, the peak flow rate in the false lumen was 293 cm 3 /s, and 72 cm 3 /s in the true lumen, whereas the cycle-averaged values were cm 3 /s and 27.1 cm 3 /s respectively. Hence, about 80% of the peak flow was diverted to the false lumen. As shown in Figure 3, the measured and computed flow rate waveforms are similar in shape but the CFD model over-predicted flow in the false lumen and under-predicted flow in the true lumen. The differences between the computed and measured flow rates were 8.5% for the true lumen and 25% for the false lumen at peak flow rate (the 8

9 cycle-averaged values were 35% for the true lumen and 28% for the false lumen). A number of factors could have contributed to the differences; delineation of the lumen contours on PC-MRI images; motion of the intra-arterial septum; limited spatial resolution, noise and apparent artefacts associated with the PC-MRI velocity data. 3.2 Comparison of flow structure and velocity profiles Comparisons were made between the time-varying velocity contours from PC-MRI measurements and flow simulation results at plane 3 (defined in Figure 1(b)) for all three velocity components. Figures 4 7 present the velocity contours in the main inferior-superior (labelled FH, foot-head), secondary AP (anterior-posterior), and RL (right-left) directions extracted from the PC-MRI data and simulations at four time points along the cardiac cycle. Both sets of data are displayed in the conventional MRI direction, looking towards the head. The corresponding magnitude images from the PC-MRI are included, indicating the shape and size of the false (FL) and true lumen (TL). As can be seen, the FL is approximately four times larger than the TL at this location. For better understanding of the complex flow patterns, secondary velocity vectors have been superimposed on the FH velocity contours. Complementary instantaneous streamlines for the four time points are shown in Figure 8. At mid-systolic acceleration, the velocity contours (Figure 4) show that the main direction of the flow in the TL was from superior to inferior (distal) with a maximum velocity of 0.45 m/s based on PC-MRI. The high velocity flow was skewed towards the left-anterior side of the TL owing to the curvature of the arch; a similar pattern can be seen in the simulation result. The flow in the FL showed more spatial variation than in the TL. The simulation results captured the relatively high velocity at the left anterior side near the septum and in the middle of the FL. The corresponding 9

10 secondary velocity vectors show that in the TL the direction of secondary flow was predominantly anterior-posterior, pointing to the right. Similar patterns can also be observed in the AP and RL contours. The proportion of the flow remaining in the TL was accelerated by the narrowing of the lumen, so stretching the helical pattern induced by the non-planar arch. In the FL the pattern was more complex, with a weak vortex centred near the right (R) wall, but extending across most of the area. The vortex originated from the flow entering at the tear proximally to this plane, curving along the opposite wall, setting up a large proximal vortex (Figure 8(a)), which expanded to fill the lumen by half-way along the descending thoracic aorta. At peak systole (Figure 5); the PC-MRI flow patterns in the TL showed fairly uniform high velocities at this location, which were well captured by the CFD simulation. The corresponding streamlines and secondary velocity vectors again reflected the deviation of the TL axis from the FH direction. In the FL the pattern had changed in response to the higher velocities through the tear, shown clearly in Figure 8(b). The vortex previously centred near the right wall had moved anteriorly and the effect of the stronger jet deflected along the left wall could be seen (recall flow is shown from the inferior aspect, as with the MRI convention). The high velocities along the left wall resulted from the jet through the tear as it impacted the opposite wall and followed the curvature of the arch; at plane 3 (Figure 8(b)) the jet had spread to fill the cross-section, with lower velocities towards the right-anterior wall resulting from the greater expansion of the jet distal to the separated, recirculating flow immediately below the tear. At mid-systolic deceleration (Figure 6), flow in the TL was still dominated by the superior- inferior component, and the velocity distribution was similar to that at peak systole, with a good agreement between measured and simulated velocities. There 10

11 was a subtle change in flow near the anterior wall as a result of the helical flow in the aortic arch induced by flow deceleration, as seen in the instantaneous streamlines (Figure 8(c)). The effect of the retardation was clearer in the FL. The flow distal to the weaker jet through the tear was more disorganised, as shown in Figure 8(c), whilst in the region of Plane 3 the somewhat disorganised flow became more evident. In Figure 6 the simulation showed the high velocity zone having moved farther along the right wall than the measurements, while the secondary vectors revealed that the main vortex had moved towards the centre of the area and a weak secondary vortex had formed at the left-posterior wall. The simulation predicted significant turbulence in the FL distal to the tear, particularly in late systole (Figure 9). Comparisons of velocities in early diastole, when the maximum retrograde flow occurred in the proximal ascending aorta, are given in Figure 7. All velocity contours from MR and CFD showed excellent agreement in both lumens. The TL was dominated by a helical flow in the superior- inferior direction, despite the area mean flow in the ascending aorta being retrograde. The corresponding streamlines and secondary vectors revealed a complex flow structure in the arch (Figure 8(d)). Flow in the FL at Plane 3 showed retrograde flow on the left-anterior area, occupying two thirds of the cross-sectional area, whilst it was antegrade in the remaining third, at the right-posterior aspect (Figure 7). The streamlines reflected this feature, where it would appear from Figure 8(d) that part of the flow changed direction approximately one diameter distal to Plane 3. Quantitative comparisons were made for the maximum velocities in the TL and FL between the PC-MRI data and CFD results. The maximum difference of instantaneous velocities in both TL and FL was found at the systolic mid-deceleration phase, when the TL velocity was 29% higher with the PC-MRI measurement than with the CFD 11

12 prediction, whilst the FL velocity was 30% higher with the CFD than with the PC- MRI. For the overall time-averaged comparison, the equivalent differences were 20% and 16 %. Reasons for the over-prediction of FL velocity have been explained in the preceding section. 4. Discussion There have been a few limited examples of such studies in the literature; Tse et al [3] examined a dissected aorta pre- and post-aneurysm, whilst Karmonik et al [2] reported on a chronic type III dissection both at initial examination and at 10-month follow-up. Neither of the studies incorporated a transitional or turbulence model in their CFD simulations. Based on the stability diagram adopted by Kousera et al. [8], the combination of peak Reynolds number and Womersley parameter considered here is likely in the region of disturbed flow, justifying the need for a transitional flow model With regard to boundary conditions. Karmonik et al. [2] used patient-specific flow waveform measured with PC-MRI as the inlet boundary condition, while Tse et al. [3] applied a typical aortic flow waveform at the inlet and a corresponding pressure waveform at the exits in the iliac arteries. Although Karmonik et al. [2] showed comparison of PC-MRI and CFD predicted velocities at a transverse plane in the descending aorta, it was for the axial through-plane velocity magnitudes only. Detailed assessment of CFD predictions using MR velocity imaging in three orthogonal directions is lacking. False lumen flow rate is a key predictor of FL patency, being the most important predictor of adverse early and later outcomes [6]. An interesting finding of Cheng et al. [5] was the correlation between the FL flow rate and the size and location of the primary entry tear, based on the computational results of four patient-specific models with the same assumptions and simplified boundary conditions as employed here. 12

13 Comparison of the FL flow rate obtained from the CFD simulation and that from the PC-MRI data (Figure 3) showed that the computational model gave comparable results to the MR measurements with similar flow waveforms for each lumen, and the percentage of flow in the FL (80% vs. 76%). The size and location of the primary entry tear and the percentage of FL flow rate extracted from the MR data were found to fit well to the regression lines presented by Cheng et al. [5]. Further careful comparison was made between the 4D PC-MRI velocity data and the simulation results at the proximal mid-descending aorta. The velocity data were compared in each of the three components. It was found that (Figures 4 7) velocity contours derived from the CFD simulation were in good agreement with those from PC-MRI. No retrograde flow was found in the TL, as the dominant velocity component (in the IS or FH direction) was directed from head to feet throughout the cardiac cycle. The other two velocity components also showed consistent patterns in pointing towards the posterior and right directions respectively, caused mainly by the inclination of the TL to the FH direction. The organized flow pattern in the TL, which was also demonstrated in previous studies [2-5], was related to its compressed size and relatively straight geometry. Flow patterns in the FL were much more complicated, seen both in the contours (Figures 4-7) and related instantaneous streamlines (Figure 8). The main flow was generally in the superior-inferior direction and the flow velocity was lower in the other two directions. At mid-systolic acceleration, no clear velocity pattern can be observed in the FH direction but CFD results successfully captured the patterns in the AP and RL directions. By peak systole, the FH velocity was higher near the left wall where CFD and PC-MRI data showed the same pattern. However, the other two directions showed weaker agreement. One likely reason for this was the patchy nature of the PC-MRI 13

14 data which was especially amplified when velocity was low. Another key reason might be the rigid wall assumption in the CFD simulations. The movement of the dissection flap is likely to be most significant at peak systole when the pressure difference between the TL and FL is at the highest [10]. Although the intimal flap was found to have been calcified and quite stiff in the particular case concerned here, small motions could still happen, hence affect the flow velocity near the flap especially in the AP and RL directions. During retardation (Figure 6) the agreement between simulations and PC-MRI was good for all velocity components. The TL flow remained antegrade, whilst there was a substantial retrograde zone in the FL at plane 3. It could be discerned from the streamlines in Figure 8(c) that flow was largely disturbed and recirculating. There was a good agreement between PC-MRI and simulations at the maximal retrograde flow in early diastole as seen in the velocity contours of Figure 7. Considerably disorganised flow in the FL was also evident in Figure 8(d). In the region of the tear there was major recirculation but, because the septum does not lie perpendicular to the oblique sagittal plane, it remains difficult to discern the boundary between FL and TL. In summary, the computational model successfully captured the complex regions of flow reversal and recirculation qualitatively, although quantitative differences exist. The overall good degree of agreement confirmed the validity of the computational model utilized in our previous case studies, providing reliable data on flow patterns and hemodynamic parameters. Limitations The CFD model presented here involved several assumptions. First, the aortic wall and dissection flap were assumed to be rigid. While this assumption was acceptable in the case discussed here owing to its stiff flap, this might not be true in cases when the 14

15 flap is more compliant. The dissection flap is initially very mobile immediately after the dissection has occurred, but becomes more rigid over time. Ganten et al. [11] examined the intimal flap and wall motion in 32 type B aortic dissection patients by using dynamic, ECG-gated CT imaging technique. It was found that distensibility of the dissected descending aorta was significantly lower than that in healthy subjects of the same age, and the average true lumen narrowing by intimal flap motion was 4.4% (maximum 29%). However, in 14 of the 32 patients there was no detectable flap motion. Another study based on a smaller number of cases demonstrated the highly variable flap motion in type B dissections [10], with up to 30% change in true lumen area. Using 2D PC-MRI in a longitudinal study, Karmonik et al. [12] found that flap motion in type B aortic dissections reduced over time. The exclusion of the arch branches is another assumption in this study. To compensate for the flow loss through the three branches, the inlet flow rate at the aortic root was scaled down to maintain the correct amount of flow into the descending aorta. This appeared to give satisfactory results, although the flow structure in the entry tear region would have been compromised. However, owing to the nature of the geometry of dissected aorta, the flow pattern is significantly changed after passing through the tear into the false lumen, as well as in the highly compressed true lumen. In conclusion, we have demonstrated good agreement in flow structure and velocity contours in the dissected aorta, proving the validity of the computational model and the simulation approach for type B aortic dissection with a relatively stiff dissection flap. Future studies are needed to examine the effect of flap motion on flow in the true and false lumen. 15

16 Acknowledgement Zhuo Cheng was supported by a scholarship from the Institute of Biomedical Engineering and the National Heart and Lung Institute, Imperial College London. The authors also wish to acknowledge funding support from the Imperial College Healthcare Charity. References [1] Steinman, D. A Image-Based Computational Fluid Dynamics Modeling in Realistic Arterial Geometries. Ann. Biomed. Eng. 30(4): [2] Karmonik, C., Partovi, S., Müller-Eschner, M., Bismuth, J., Davies, M. G., Shah, D. J., Loebe, M., Böckler, D., Lumsden, A. B., von Tengg-Kobligk, H., Longitudinal computational fluid dynamics study of aneurysmal dilatation in a chronic DeBakey type III aortic dissection. Journal of Vascular Surgery 56, [3] Tse, K. M., Chiu, P., Lee, H. P., Ho, P., Investigation of hemodynamics in the development of dissecting aneurysm within patient-specific dissecting aneurismal aortas using computational fluid dynamics (CFD) simulations. Journal of Biomechanics 44, [4] Cheng, Z., Tan, F. P. P., Riga, C. V., Bicknell, C. D., Hamady, M. S., Gibbs, R. G. J., Wood, N. B., Xu, X. Y., Analysis of flow patterns in a patient-specific aortic dissection model. Journal of Biomechanical Engineering 132, [5] Cheng, Z., Riga, C. V., Chan, J., Hamady, M. S., Wood, N. B., Cheshire, N. J. W., Xu, X. Y., Gibbs, R. G. J., Computational Simulation of the Aorta in Acute 16

17 Type B Dissection: Initial Findings and Potential Applicability. Journal of Vascular Surgery 57, 35S-43S. [6] Eggebrecht, H., Herold, U., Kuhnt, O., Schmermund, A., Bartel, T., Martini, S., Lind, A., Naber, C. K., Kienbaum, P., Kuhl, H., Peters, J., Jakob, H., Erbel, R. & Baumgart, D., Endovascular stent graft treatment of aortic dissection: determinants of post interventional outcome. European Heart Journal 26, [7] Clough, R.E., Waltham, M., Giese D., Taylor P.R., Schaeffter T., A new imaging method for assessment of aortic dissection using four-dimensional phase contrast magnetic resonance imaging. Journal of Vascular Surgery 55, [8] Menter, F., Langtry, R., and Volker, S., Transition modelling for general purpose CFD codes. Flow Turbulence Combust 77, [9] Kousera, C. A., Wood, N. B., Seed, W. A., Torii, R., O Regan, D., Xu, X. Y., A numerical study of aortic flow stability and comparison with in vivo flow measurements. Journal of Biomechanical Engineering 135, [10] Murayyama, T., Funabashi, N., Uehara, M., Takaoka, H., Komuro, Issei, New classification of aortic dissection during the cardiac cycle as pulsating type and static type evaluated by electrocardiogram-gated multislice CT. International Journal of Cardiology 142, [11] Ganten, M. K., Weber, T. F., von Tengg-Kobligk, H., Bockler, D., Stiller, W., Geisbusch, P., Kauffmann, G. W., Delorme, S., Bock, M. & Kauczor, H. U. (2009), 17

18 Motion Characterization of Aortic Wall and Intimal Flap by ECG-Gated CT in Patients With Chronic B-Dissection, Eur. J. Radiol. 72: [12] Karmonik, C., Duran, C., Shah, D. J., Anaya-Ayala, J. E., Davies, M. G., Lumsden, A. B., Bismuth, J., Preliminary findings in quantification of changes in septal motion during follow-up of type B aortic dissections. Journal of Vascular Surgery 55,

19 Figure 1: Reconstructed geometries of the aortic dissection used in validation. (a) The entire aorta including the ascending aorta lumen (AL), the aortic arch branches, the descending aorta lumen (DL), and the iliac arteries (IA), but excluding the branches off the descending thoracic and abdominal aorta; (b) the locations of three imaging planes where phase contrast MR velocity mapping was acquired, and (c) the computational model used in validation, with arrows indicating the locations of inlet, outlet, tear, false and true lumen. Figure 2: The flow rate waveforms at imaging plane 1 and plane 2 as defined in Figure 1 (b). The flow rate was calculated based on the converted velocity at each pixel and the pixel size of the PC-MRI data. Figure 3: The flow rate waveforms of the true and false lumen from both CFD results and PC-MRI velocity data at imaging plane 3. Figure 4: Comparison of velocity profiles in FH, AP and RL directions at mid-systolic acceleration phase of the cardiac cycle between PC-MRI velocity data (in m/s) and simulation results. In Figures 4 7 the red colour represents positive velocities from superior to inferior, anterior to posterior (IS contours), right to left (AP and RL contours); the blue colour represents negative velocities. Note different colour scales for different directions and time points according to the range of velocity values. The secondary velocity vectors are also presented as project on the plane. Figure 5: Comparison of velocity profiles (in m/s) between PC-MRI velocity data and simulation results in FH, AP and RL directions at peak systole. 19

20 Figure 6: Comparison of velocity profiles (in m/s) between PC-MRI velocity data and simulation results in FH, AP and RL directions at systolic deceleration phase. Figure 7: Comparison of velocity profiles (in m/s) between PC-MRI velocity data and simulation results in FH, AP and RL directions at maximum retrograde flow in early diastole. Figure 8: Instantaneous streamlines of blood flow from left posterior aspect at (a) systolic mid-acceleration phase, (b) peak systole, (c) systolic mid-deceleration phase, and (d) maximum retrograde flow in diastole. Figure 9: Turbulence intensity isosurfaces at mid-systolic deceleration from left posterior (left) and right anterior (right) aspects. 20

21 Figure 1. Reconstructed geometries of the aortic dissection used in validation. (a) The entire aorta including the ascending aorta lumen (AL), the aortic arch branches, the descending aorta lumen (DL), and the iliac arteries (IA), but excluding the branches off the descending thoracic and abdominal aorta; (b) the locations of three imaging planes where phase contrast MR velocity mapping was acquired, and (c) the computational model used in validation, with arrows indicating the locations of inlet, outlet, tear, false and true lumen. 21

22 Figure 2. The flow rate waveforms at imaging plane 1 and plane 2 as defined in Figure 1 (b). The flow rate was calculated based on the converted velocity at each pixel and the pixel size of the PC-MRI data. 22

23 Figure 3. The flow rate waveforms of the true and false lumen from both CFD results and PC-MRI velocity data at imaging plane

24 Figure 4. Comparison of velocity profiles in FH, AP and RL directions at midsystolic acceleration phase of the cardiac cycle between MR velocity data (in m/s) and simulation results. In Figures 4 7 the red colour represents positive velocities from superior to inferior, anterior to posterior (IS contours), right to left (AP and RL contours); the blue colour represents negative velocities. Note different colour scales for different directions and time points according to the range of velocity values. The secondary velocity vectors are projected on the plane and included in the velocity contours of FH component. 24

25 Figure 5. Comparison of velocity profiles (in m/s) between PC-MRI velocity data and simulation results in FH, AP and RL directions at peak systole. 25

26 Figure 6. Comparison of velocity profiles (in m/s) between PC-MRI velocity data and simulation results in FH, AP and RL directions at systolic deceleration phase. 26

27 Figure 7. Comparison of velocity profiles (in m/s) between PC-MRI velocity data and simulation results in FH, AP and RL directions at maximum retrograde flow in early diastole. 27

28 Figure 8. Instantaneous streamlines of blood flow from left posterior aspect at (a) systolic mid-acceleration phase, (b) peak systole, (c) systolic mid-deceleration phase, and (d) maximum retrograde flow in diastole. 28

29 Figure 9. Turbulence intensity isosurfaces at mid-systolic deceleration from left posterior (left) and right anterior (right) aspects. 29

4D model of hemodynamics in the abdominal aorta

4D model of hemodynamics in the abdominal aorta Bio-Medical Materials and Engineering 26 (2015) S257 S264 DOI 10.3233/BME-151312 IOS Press S257 4D model of hemodynamics in the abdominal aorta Ireneusz Zbicinski a,*, Natalia Veshkina a and Ludomir Stefa

More information

CFD Challenge: Simulation of Hemodynamics in a Patient-Specific Aortic Coarctation Model

CFD Challenge: Simulation of Hemodynamics in a Patient-Specific Aortic Coarctation Model CFD Challenge: Simulation of Hemodynamics in a Patient-Specific Aortic Coarctation Model Background Coarctation of the aorta (CoA) accounts for 8%-11% of congenital heart defects, affecting tens of thousands

More information

Longitudinal computational fluid dynamics study of aneurysmal dilatation in a chronic DeBakey type III aortic dissection

Longitudinal computational fluid dynamics study of aneurysmal dilatation in a chronic DeBakey type III aortic dissection Longitudinal computational fluid dynamics study of aneurysmal dilatation in a chronic DeBakey type III aortic dissection Christof Karmonik, PhD, a Sasan Partovi, MD, a,b Matthias Müller-Eschner, MD, b,c

More information

La dissection aortique de type B : Dépistage et Suivi

La dissection aortique de type B : Dépistage et Suivi La dissection aortique de type B : Dépistage et Suivi Philippe Cluzel Département d Imagerie Cardiovasculaire et de Radiologie Interventionnelle et Thoracique (DICVRIT) Sorbonne Université Médecine, UMR

More information

Refinements in Mathematical Models to Predict Aneurysm Growth and Rupture

Refinements in Mathematical Models to Predict Aneurysm Growth and Rupture Refinements in Mathematical Models to Predict Aneurysm Growth and Rupture RAMON BERGUER, a,b JOSEPH L. BULL, a,b AND KHALIL KHANAFER a a Vascular Mechanics Laboratory, Department of Biomedical Engineering,

More information

Arteriovenous Graft Modeling and Hemodynamic Interpretation

Arteriovenous Graft Modeling and Hemodynamic Interpretation Open Journal of Fluid Dynamics, 2012, 2, 324-330 http://dx.doi.org/10.4236/ojfd.2012.24a040 Published Online December 2012 (http://www.scirp.org/journal/ojfd) Arteriovenous Graft Modeling and Hemodynamic

More information

Numerical simulations of fluid mechanical interactions between two abdominal aortic branches

Numerical simulations of fluid mechanical interactions between two abdominal aortic branches Korea-Australia Rheology Journal Vol. 16, No. 2, June 2004 pp. 75-83 Numerical simulations of fluid mechanical interactions between two abdominal aortic branches Taedong Kim, Taewon Seo* 1,2 and Abdul.I.

More information

Morphological analysis of the thoracic aorta in case of TBAD without treatment.

Morphological analysis of the thoracic aorta in case of TBAD without treatment. Master project: Hemodynamic pattern of type B aortic dissection progression and remodelling of the false lumen after endovascular treatment: imaging informed numerical simulations Aortic dissection is

More information

Computational Study of Haemodynamic Effects of Entry- and Exit-Tear Coverage in a DeBakey Type III Aortic Dissection: Technical Report

Computational Study of Haemodynamic Effects of Entry- and Exit-Tear Coverage in a DeBakey Type III Aortic Dissection: Technical Report Eur J Vasc Endovasc Surg (2011) 42, 172e177 Computational Study of Haemodynamic Effects of Entry- and Exit-Tear Coverage in a DeBakey Type III Aortic Dissection: Technical Report C. Karmonik a,b, *, J.

More information

Numerical Simulation of Blood Flow through Asymmetric and Symmetric Occlusion in Carotid Artery

Numerical Simulation of Blood Flow through Asymmetric and Symmetric Occlusion in Carotid Artery Proceedings of the 3 rd International Conference on Fluid Flow, Heat and Mass Transfer (FFHMT 16) Ottawa, Canada May 2 3, 2016 Paper No. 170 Numerical Simulation of Blood Flow through Asymmetric and Symmetric

More information

Non-Newtonian pulsatile blood flow in a modeled artery with a stenosis and an aneurysm

Non-Newtonian pulsatile blood flow in a modeled artery with a stenosis and an aneurysm Non-Newtonian pulsatile blood flow in a modeled artery with a stenosis and an aneurysm I. Husain, C. Langdon and J. Schwark Department of Mathematics Luther College University of Regina Regina, Saskatchewan

More information

J. Laustsen ~, W. P. Paaske ~, S. Oyre 2 and E. Morre Pedersen ~'2

J. Laustsen ~, W. P. Paaske ~, S. Oyre 2 and E. Morre Pedersen ~'2 Eur J Vasc Endovasc Surg 9, 383-388 (1995) Dynamic Quantification, Visualisation and Animation of Blood Velocities and Flows in Infrarenal Aortic Aneurysms in vivo by Three-Dimensional MR Phase Velocity

More information

A Magnetic Resonance Imaging Method for

A Magnetic Resonance Imaging Method for Journal of Cardiovascular Magnetic Resonance, 1(1), 59-64 (1999) INVITED PAPER Use of MRI in ASD Asessment A Magnetic Resonance Imaging Method for Evaluating Atrial Septa1 Defects Godtfred Holmvang Cardiac

More information

Numerical analysis of blood flow in human abdominal aorta

Numerical analysis of blood flow in human abdominal aorta Advances in Fluid Mechanics VI 603 Numerical analysis of blood flow in human abdominal aorta M. Podyma 1, I. Zbicinski 1, J. Walecki 2, M. L. Nowicki 2, P. Andziak 3, P. Makowski 4 & L. Stefanczyk 5 1

More information

CPM Specifications Document Aortofemoral Normal:

CPM Specifications Document Aortofemoral Normal: CPM Specifications Document Aortofemoral Normal: OSMSC 0110_0000 May 27, 2013 Version 1 Open Source Medical Software Corporation 2013 Open Source Medical Software Corporation. All Rights Reserved. 1. Clinical

More information

Magnetic Resonance Angiography

Magnetic Resonance Angiography Magnetic Resonance Angiography 1 Magnetic Resonance Angiography exploits flow enhancement of GR sequences saturation of venous flow allows arterial visualization saturation of arterial flow allows venous

More information

Nouveaux marqueurs de la pathologie de l aorte thoracique

Nouveaux marqueurs de la pathologie de l aorte thoracique Nouveaux marqueurs de la pathologie de l aorte thoracique 1- I2MR, Inserm, CHU de Rangueil, Toulouse, 2- I3M, Université de Montpellier 2, Montpellier, 3- ALARA OCFIA (ANR 2007) optimised computational

More information

ISSUES ON COMPUTATIONAL MODELING FOR COMPUTATION-AIDED DIAGNOSIS 臨床診断支援ツールのための計算力学モデリング

ISSUES ON COMPUTATIONAL MODELING FOR COMPUTATION-AIDED DIAGNOSIS 臨床診断支援ツールのための計算力学モデリング ISSUES ON COMPUTATIONAL MODELING FOR COMPUTATION-AIDED DIAGNOSIS 臨床診断支援ツールのための計算力学モデリング Hao LIU Advanced Computer and Information Division, RIKEN 2-1, Hirosawa, Wako-shi, Saitama 351-0198 JAPAN e-mail:

More information

CPM Specifications Document Aortic Coarctation: Exercise

CPM Specifications Document Aortic Coarctation: Exercise CPM Specifications Document Aortic Coarctation: Exercise OSMSC 0091_2000 0102_2000 0107_0000 0111_0000 May 29, 2013 Version 1 Open Source Medical Software Corporation 2013 Open Source Medical Software

More information

Blood flow in vessels with artificial or pathological geometrical changes

Blood flow in vessels with artificial or pathological geometrical changes Blood flow in vessels with artificial or pathological geometrical changes P. Tibaut 1, B. Wiesler 1, M. Mayer 2 & R. Wegenkittel 3 1 AVL LIST GmbH, Graz, Austria 2 VRVIs, Vienna, Austria 3 Tiani Medgraph

More information

MR Advance Techniques. Vascular Imaging. Class II

MR Advance Techniques. Vascular Imaging. Class II MR Advance Techniques Vascular Imaging Class II 1 Vascular Imaging There are several methods that can be used to evaluate the cardiovascular systems with the use of MRI. MRI will aloud to evaluate morphology

More information

The risk of stanford type A aortic dissection with different tear size and location: a numerical study

The risk of stanford type A aortic dissection with different tear size and location: a numerical study DOI 10.1186/s12938-016-0258-y BioMedical Engineering OnLine RESEARCH Open Access The risk of stanford type A aortic dissection with different tear size and location: a numerical study Yue Shi 1, Minjia

More information

ON FLOW DYNAMICS IN TYPE B AORTIC DISSECTION (TBAD)

ON FLOW DYNAMICS IN TYPE B AORTIC DISSECTION (TBAD) ON FLOW DYNAMICS IN TYPE B AORTIC DISSECTION (TBAD) A. Rabin 1, R. Karmeli 1, P. Bar-Yoseph 2 1- Vascular & Endovascular surgery department Hadassah university hospital, Jerusalem, Israel 2- Mechanical

More information

Case 9799 Stanford type A aortic dissection: US and CT findings

Case 9799 Stanford type A aortic dissection: US and CT findings Case 9799 Stanford type A aortic dissection: US and CT findings Accogli S, Aringhieri G, Scalise P, Angelini G, Pancrazi F, Bemi P, Bartolozzi C Department of Diagnostic and Interventional Radiology, University

More information

Material characterization of HeartPrint models and comparison with arterial tissue properties

Material characterization of HeartPrint models and comparison with arterial tissue properties Material characterization of HeartPrint models and comparison with arterial tissue properties Over the years, catheter-based interventions have gained popularity for the treatment of cardiovascular diseases

More information

Finite element modeling of the thoracic aorta: including aortic root motion to evaluate the risk of aortic dissection

Finite element modeling of the thoracic aorta: including aortic root motion to evaluate the risk of aortic dissection Journal of Medical Engineering & Technology, Vol. 32, No. 2, March/April 2008, 167 170 Short Communication Finite element modeling of the thoracic aorta: including aortic root motion to evaluate the risk

More information

Contents 1 Computational Haemodynamics An Introduction 2 The Human Cardiovascular System

Contents 1 Computational Haemodynamics An Introduction 2 The Human Cardiovascular System Contents 1 Computational Haemodynamics An Introduction... 1 1.1 What is Computational Haemodynamics (CHD)... 1 1.2 Advantages of CHD... 3 1.3 Applications in the Cardiovascular System... 4 1.3.1 CHD as

More information

Is a Flat Inlet Profile Sufficient for WSS Estimation in the Aortic Arch?

Is a Flat Inlet Profile Sufficient for WSS Estimation in the Aortic Arch? Is a Flat Inlet Profile Sufficient for WSS Estimation in the Aortic Arch? J. Renner 1, D. Loyd 1, T. Länne 2, M. Karlsson 1 1 Department of Management and Engineering 2 Department of Medical and Health

More information

Computational Fluid Dynamics Analysis of Blood Flow in Human Aorta

Computational Fluid Dynamics Analysis of Blood Flow in Human Aorta Computational Fluid Dynamics Analysis of Blood Flow in Human Aorta Yogesh V. Borse 1, Prof. S.A. Giri 2 M. Tech Scholar, Dept of Mechanical Engg, Ramdeobaba College of Engineering and Management, Nagpur,

More information

Late False Lumen Expansion Predicted by Preoperative Blood Flow Simulation in a Patient with Chronic Type B Aortic Dissection

Late False Lumen Expansion Predicted by Preoperative Blood Flow Simulation in a Patient with Chronic Type B Aortic Dissection Accepted Manuscript Late False Lumen Expansion Predicted by Preoperative Blood Flow Simulation in a Patient with Chronic Type B Aortic Dissection Chikara Ueki, MD, Hiroshi Tsuneyoshi, MD, PhD PII: S0022-5223(18)32652-7

More information

EVALUATION OF ABDOMINAL AORTIC ANEURYSM WALL STESS BASED ON FLOW INDUCED LOAD

EVALUATION OF ABDOMINAL AORTIC ANEURYSM WALL STESS BASED ON FLOW INDUCED LOAD International Journal of Mechanical Engineering and Technology (IJMET) Volume 9, Issue 11, November 2018, pp. 684 688, Article ID: IJMET_09_11_068 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=9&itype=11

More information

FLUID MECHANICAL PERTURBATIONS INDUCED BY STENT IMPLANTATION: A NUMERICAL STUDY

FLUID MECHANICAL PERTURBATIONS INDUCED BY STENT IMPLANTATION: A NUMERICAL STUDY LABORATORY OF BIOLOGICAL STRUCTURE MECHANICS www.labsmech.polimi.it FLUID MECHANICAL PERTURBATIONS INDUCED BY STENT IMPLANTATION: A NUMERICAL STUDY Rossella Balossino, Francesca Gervaso, Francesco Migliavacca,

More information

Assessment of wall shear stress in patients without aortic disease and with aortic dissection using velocity encoding 4D MRI

Assessment of wall shear stress in patients without aortic disease and with aortic dissection using velocity encoding 4D MRI Assessment of wall shear stress in patients without aortic disease and with aortic dissection using velocity encoding 4D MRI Poster No.: C-0841 Congress: ECR 2015 Type: Scientific Exhibit Authors: J. P.

More information

Simulations of the blood flow in the arterio-venous fistula for haemodialysis

Simulations of the blood flow in the arterio-venous fistula for haemodialysis Acta of Bioengineering and Biomechanics Vol. 16, No. 1, 2014 Original paper DOI: 10.5277/abb140109 Simulations of the blood flow in the arterio-venous fistula for haemodialysis DANIEL JODKO*, DAMIAN OBIDOWSKI,

More information

Impaired Regional Myocardial Function Detection Using the Standard Inter-Segmental Integration SINE Wave Curve On Magnetic Resonance Imaging

Impaired Regional Myocardial Function Detection Using the Standard Inter-Segmental Integration SINE Wave Curve On Magnetic Resonance Imaging Original Article Impaired Regional Myocardial Function Detection Using the Standard Inter-Segmental Integration Ngam-Maung B, RT email : chaothawee@yahoo.com Busakol Ngam-Maung, RT 1 Lertlak Chaothawee,

More information

CFD Analysis of Pulsatile Flow and Non-Newtonian Behavior of Blood in Arteries

CFD Analysis of Pulsatile Flow and Non-Newtonian Behavior of Blood in Arteries Copyright 2015 Tech Science Press MCB, vol.12, no.1, pp.37-47, 2015 CFD Analysis of Pulsatile Flow and Non-Newtonian Behavior of Blood in Arteries P. Jhunjhunwala,, P.M. Padole, and S.B. Thombre, Abstract:

More information

Cardiac Physiology an Overview

Cardiac Physiology an Overview Cardiac Physiology an Overview Dr L J Solomon Department of Paediatrics and Child Health School of Medicine Faculty of Health Sciences University of the Free State and PICU Universitas Academic Hospital

More information

EasyChair Preprint. Computational Fluid Dynamics Simulations of Flow in the Renal Arteries after Stent Graft Implantation

EasyChair Preprint. Computational Fluid Dynamics Simulations of Flow in the Renal Arteries after Stent Graft Implantation EasyChair Preprint 259 Computational Fluid Dynamics Simulations of Flow in the Renal Arteries after Stent Graft Implantation Tianyi Xia, Matthew Doyle, Thomas Forbes and Cristina H. Amon EasyChair preprints

More information

Acute Aortic Syndromes

Acute Aortic Syndromes Acute Aortic Syndromes Carole J. Dennie, MD Acute Thoracic Aortic Syndromes Background Non-Traumatic Acute Thoracic Aortic Syndromes Carole Dennie MD FRCPC Associate Professor of Radiology and Cardiology

More information

Open fenestration for complicated acute aortic B dissection

Open fenestration for complicated acute aortic B dissection Art of Operative Techniques Open fenestration for complicated acute aortic B dissection Santi Trimarchi 1, Sara Segreti 1, Viviana Grassi 1, Chiara Lomazzi 1, Marta Cova 1, Gabriele Piffaretti 2, Vincenzo

More information

UK Biobank. Imaging modality Cardiovascular Magnetic Resonance (CMR) Version th Oct 2015

UK Biobank. Imaging modality Cardiovascular Magnetic Resonance (CMR) Version th Oct 2015 Imaging modality Cardiovascular Magnetic Resonance (CMR) Version 1.0 http://www.ukbiobank.ac.uk/ 30 th Oct 2015 This document details the procedure for the CMR scan performed at an Imaging assessment centre

More information

Flow Analysis with Stent Placement in the Cerebral Aneurysm

Flow Analysis with Stent Placement in the Cerebral Aneurysm Proceedings of the ECCOMAS Thematic International Conference on Simulation and Modeling of Biological Flows (SIMBIO 2011) September 21-23, 2011, VUB, Brussels, Belgium Flow Analysis with Stent Placement

More information

Go With The Flow: Role of 4D Flow Imaging

Go With The Flow: Role of 4D Flow Imaging 4D Flow Go With The Flow: Role of 4D Flow Imaging Niti R. Aggarwal, MD Associate Director of Cardiac MRI Assistant Professor of Medicine & Radiology University of Wisconsin Madison Disclosures GE Healthcare

More information

Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with and without Bypass Graft

Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with and without Bypass Graft Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with and without Bypass Graft BURASKORN NUNTADILOK 1, BENCHAWAN WIWATANAPATAPHEE 1 MEECHOKE CHUEDOUNG 1, THANONGCHAI SIRIAPISITH

More information

Update on Acute Aortic Syndrome

Update on Acute Aortic Syndrome SUNDAY Update on Acute Aortic Syndrome Diana Litmanovich, MD Learning objectives To be familiar with the definition, natural history, and imaging findings of acute aortic syndrome, including: I. Aortic

More information

Simulating the Motion of Heart Valves Under Fluid Flows Induced by Cardiac Contraction

Simulating the Motion of Heart Valves Under Fluid Flows Induced by Cardiac Contraction Simulating the Motion of Heart Valves Under Fluid Flows Induced by Cardiac Contraction Eann A. Patterson Department of Mechanical Engineering, The University of Sheffield Mappin Street, Sheffield, S1 3JD

More information

ACUTE AORTIC SYNDROMES

ACUTE AORTIC SYNDROMES ACUTE AORTIC SYNDROMES AGNETA FLINCK MD, PhD Dept. of Thoracic Radiology Sahlgrenska University Hospital ACUTE AORTIC SYNDROMES Aortic dissection Intramural hematoma (IMH) 5-20% Penetrating atherosclerotic

More information

CFD Study of the Blood Flow in Cerebral Aneurysms Treated with Flow Diverter Stents

CFD Study of the Blood Flow in Cerebral Aneurysms Treated with Flow Diverter Stents CFD Study of the Blood Flow in Cerebral Aneurysms Treated with Flow Diverter Stents Augusto F. Sanches and Eva Gutheil Interdisciplinary Center for Scientific Computing, Heidelberg University Flow diverters

More information

Effects of Aortic Root Motion on Wall Stress in the Marfan Aorta Before and After

Effects of Aortic Root Motion on Wall Stress in the Marfan Aorta Before and After 1 2 3 4 5 6 7 8 9 10 11 12 13 Effects of Aortic Root Motion on Wall Stress in the Marfan Aorta Before and After Personalised Aortic Root Support (PEARS) Surgery S. D. Singh a, X. Y. Xu a,*, J. R. Pepper

More information

COMPUTER SIMULATION OF BLOOD FLOW IN ARTERIES AFFECTED BY MULTIPLE ANEURYSM

COMPUTER SIMULATION OF BLOOD FLOW IN ARTERIES AFFECTED BY MULTIPLE ANEURYSM COMPUTER SIMULATION OF BLOOD FLOW IN ARTERIES AFFECTED BY MULTIPLE ANEURYSM H. GIRIJA BAI 1 and K.B. NAIDU 2 Department of Mathematics, Sathyabama University, Chennai-600 119, Tamil Nadu, India 1 girijanameprakash@gmail.com

More information

IMAGING the AORTA. Mirvat Alasnag FACP, FSCAI, FSCCT, FASE June 1 st, 2011

IMAGING the AORTA. Mirvat Alasnag FACP, FSCAI, FSCCT, FASE June 1 st, 2011 IMAGING the AORTA Mirvat Alasnag FACP, FSCAI, FSCCT, FASE June 1 st, 2011 September 11, 2003 Family is asking $67 million in damages from two doctors Is it an aneurysm? Is it a dissection? What type of

More information

Scientific Exhibit Authors: M. Sugiyama, Y. Takehara, T. Saito, N. Ooishi, M. Alley,

Scientific Exhibit Authors: M. Sugiyama, Y. Takehara, T. Saito, N. Ooishi, M. Alley, Abnormal flow dynamics within the ascending aorta of the patients with aortic valve stenosis. Assessments with phase resolved three dimensional phase contrast MR image (4DFlow). Poster No.: C-2504 Congress:

More information

Predicting Aneurysm Rupture: Computer Modeling of Geometry and Hemodynamics

Predicting Aneurysm Rupture: Computer Modeling of Geometry and Hemodynamics Predicting Aneurysm Rupture: Computer Modeling of Geometry and Hemodynamics Robert E. Harbaugh, MD, FACS, FAHA Director, Penn State Institute of the Neurosciences University Distinguished Professor & Chair,

More information

cardiac imaging planes planning basic cardiac & aortic views for MR

cardiac imaging planes planning basic cardiac & aortic views for MR cardiac imaging planes planning basic cardiac & aortic views for MR Dianna M. E. Bardo, M. D. Assistant Professor of Radiology & Cardiovascular Medicine Director of Cardiac Imaging cardiac imaging planes

More information

Essentials of Clinical MR, 2 nd edition. 99. MRA Principles and Carotid MRA

Essentials of Clinical MR, 2 nd edition. 99. MRA Principles and Carotid MRA 99. MRA Principles and Carotid MRA As described in Chapter 12, time of flight (TOF) magnetic resonance angiography (MRA) is commonly utilized in the evaluation of the circle of Willis. TOF MRA allows depiction

More information

Studying the Flow Dynamics Within Endografts in Abdominal Aortic Aneurysms

Studying the Flow Dynamics Within Endografts in Abdominal Aortic Aneurysms Chapter 8 Studying the Flow Dynamics Within Endografts in Abdominal Aortic Aneurysms Efstratios Georgakarakos, Antonios Xenakis, George S. Georgiadis, Konstantinos C. Kapoulas, Evagelos Nikolopoulos and

More information

Indications: following: embolization. artery that has diseases 5. The evaluation. of suspected. such entities. a cold hand. biopsy

Indications: following: embolization. artery that has diseases 5. The evaluation. of suspected. such entities. a cold hand. biopsy Peripheral Arterial Ultrasound Protocol Using Color and Spectral Doppler Reviewed by: Mark Yuhasz, MD Last Review Date: January 2015 Contact: (866) 761 4200, Option 1 Indications: The indications for peripheral

More information

Normal TTE/TEE Examinations

Normal TTE/TEE Examinations Normal TTE/TEE Examinations Geoffrey A. Rose, MD FACC FASE Sanger Heart & Vascular Institute Before you begin imaging... Obtain the patient s Height Weight BP PLAX View PLAX View Is apex @ 9-10 o clock?

More information

Validation of a computational model versus a bench top model of an aortic dissection model

Validation of a computational model versus a bench top model of an aortic dissection model ORIGINAL ARTICLES Validation of a computational model versus a bench top model of an aortic dissection model Khalil Khanafer 1, 2, Marty S. Schlicht 2, Kambiz Vafai 3, Saurabh Prabhaar 4, Mohamed Gaith

More information

CPM Specifications Document Aortofemoral Normal:

CPM Specifications Document Aortofemoral Normal: CPM Specifications Document Aortofemoral Normal: OSMSC 0003_0000 0006_0000 May 24, 2013 Version 1 Open Source Medical Software Corporation 2013 Open Source Medical Software Corporation. All Rights Reserved.

More information

CT angiography in type I acute aortic dissection complicated with malperfusion - a visual review of obstruciton patterns

CT angiography in type I acute aortic dissection complicated with malperfusion - a visual review of obstruciton patterns CT angiography in type I acute aortic dissection complicated with malperfusion - a visual review of obstruciton patterns Eneva M. St. Ekaterna University Hospital Report objectives 1. Review malperfusion

More information

There has been extensive speculation in the literature about

There has been extensive speculation in the literature about TECHNICAL NOTE A. Mantha C. Karmonik G. Benndorf C. Strother R. Metcalfe Hemodynamics in a Cerebral Artery before and after the Formation of an Aneurysm SUMMARY: Using data obtained from 3D digital subtraction

More information

The study on hemodynamic effect of series type LVAD on aortic blood flow pattern: a primary numerical study

The study on hemodynamic effect of series type LVAD on aortic blood flow pattern: a primary numerical study DOI 10.1186/s12938-016-0252-4 BioMedical Engineering OnLine RESEARCH Open Access The study on hemodynamic effect of series type LVAD on aortic blood flow pattern: a primary numerical study Qi Zhang, Bin

More information

A Multiphysics Simulation of a Healthy and a Diseased Abdominal Aorta

A Multiphysics Simulation of a Healthy and a Diseased Abdominal Aorta A Multiphysics Simulation of a Healthy and a Diseased Abdominal Aorta No Author Given No Institute Given Abstract. Abdominal Aortic Aneurysm is a potentially life-threatening disease if not treated adequately.

More information

Computational Fluid Dynamics Analysis of Blalock-Taussig Shunt

Computational Fluid Dynamics Analysis of Blalock-Taussig Shunt Washington University in St. Louis Washington University Open Scholarship Mechanical Engineering and Materials Science Independent Study Mechanical Engineering & Materials Science 12-23-2017 Computational

More information

March 12th, 2018, Orlando FL. The American College of Cardiology 67 th Annual Scientific Meeting

March 12th, 2018, Orlando FL. The American College of Cardiology 67 th Annual Scientific Meeting Cavitation Phenomenon Creating Bubbles and their Explosion in the Coronary Artery Causes Damage to the Endothelium and Starts the Atheroslerotic Process Thach N. Nguyen, Nhan MT Nguyen, Tri M. Pham, Quang

More information

Malperfusion Syndromes Type B Aortic Dissection with Malperfusion

Malperfusion Syndromes Type B Aortic Dissection with Malperfusion Malperfusion Syndromes Type B Aortic Dissection with Malperfusion Jade S. Hiramoto, MD, MAS April 27, 2012 Associated with early mortality Occurs when there is end organ ischemia secondary to aortic branch

More information

Case 47 Clinical Presentation

Case 47 Clinical Presentation 93 Case 47 C Clinical Presentation 45-year-old man presents with chest pain and new onset of a murmur. Echocardiography shows severe aortic insufficiency. 94 RadCases Cardiac Imaging Imaging Findings C

More information

Research Article Hemodynamic Features in Stenosed Coronary Arteries: CFD Analysis Based on Histological Images

Research Article Hemodynamic Features in Stenosed Coronary Arteries: CFD Analysis Based on Histological Images Applied Mathematics Volume, Article ID 77, pages http://dx.doi.org/.//77 Research Article Hemodynamic Features in Stenosed Coronary Arteries: CFD Analysis Based on Histological Images Mahsa Dabagh,, Wakako

More information

Reliable World Class Insights Your Silicon Valley Partner in Simulation ANSYS Sales, Consulting, Training & Support

Reliable World Class Insights Your Silicon Valley Partner in Simulation ANSYS Sales, Consulting, Training & Support www.ozeninc.com info@ozeninc.com (408) 732 4665 1210 E Arques Ave St 207 Sunnyvale, CA 94085 Reliable World Class Insights Your Silicon Valley Partner in Simulation ANSYS Sales, Consulting, Training &

More information

Computational simulation of 4D blood flow dynamics of the thoraco-abdominal aorta: prediction of long-term changes in aneurysm morphology

Computational simulation of 4D blood flow dynamics of the thoraco-abdominal aorta: prediction of long-term changes in aneurysm morphology Computational simulation of 4D blood flow dynamics of the thoraco-abdominal aorta: prediction of long-term changes in aneurysm morphology Poster No.: B-044 Congress: ECR 2011 Type: Scientific Paper Topic:

More information

The effect of angulation in abdominal aortic aneurysms: fluid structure interaction simulations of idealized geometries

The effect of angulation in abdominal aortic aneurysms: fluid structure interaction simulations of idealized geometries DOI 10.1007/s11517-010-0714-y ORIGINAL ARTICLE The effect of angulation in abdominal aortic aneurysms: fluid structure interaction simulations of idealized geometries Michalis Xenos Yared Alemu Dan Zamfir

More information

Computational medical imaging and hemodynamics framework for functional analysis and assessment of cardiovascular structures

Computational medical imaging and hemodynamics framework for functional analysis and assessment of cardiovascular structures DOI 10.1186/s12938-017-0326-y BioMedical Engineering OnLine REVIEW Open Access Computational medical imaging and hemodynamics framework for functional analysis and assessment of cardiovascular structures

More information

Papers Arising from the Vertebral Artery Study

Papers Arising from the Vertebral Artery Study Papers Arising from the Vertebral Artery Study 1. Brief Introduction to quaternions and framed vectors and their application to the description of anatomical movements. The mathematical description of

More information

Ultrasound Physics & Terminology

Ultrasound Physics & Terminology Ultrasound Physics & Terminology This module includes the following: Basic physics terms Basic principles of ultrasound Ultrasound terminology and terms Common artifacts seen Doppler principles Terms for

More information

Flow features in and around a (stented) coarctation

Flow features in and around a (stented) coarctation Flow features in and around a (stented) coarctation BMTE04.44 Marcel van t Veer January 2004 March 2004 Supervisors: - C.A. Taylor - F.N. Van de Vosse Abstract: A coarctation is a local narrowing of the

More information

STUDY OF FLOW PHENOMENA IN AORTIC DISSECTION

STUDY OF FLOW PHENOMENA IN AORTIC DISSECTION STUDY OF FLOW PHENOMENA IN AORTIC DISSECTION Maurizio Bordone *, Eugenio Oñate *, Paula Rudenick, Bart Bijnens and Eduardo Soudah * * International Centre for Numerical Methods in Engineering (CIMNE) Campus

More information

Deb Coghlan AMS (Vascular and General ) Brisbane, Australia

Deb Coghlan AMS (Vascular and General ) Brisbane, Australia Deb Coghlan AMS (Vascular and General ) Brisbane, Australia ANEURYSMAL DIISEASE The infrarenal aorta enlarges with age, and is the commonest site for arterial aneurysms. An aneurysm is a permanent focal

More information

1Pulse sequences for non CE MRA

1Pulse sequences for non CE MRA MRI: Principles and Applications, Friday, 8.30 9.20 am Pulse sequences for non CE MRA S. I. Gonçalves, PhD Radiology Department University Hospital Coimbra Autumn Semester, 2011 1 Magnetic resonance angiography

More information

Saccular Aneurysm Formation in Curved and Bifurcating Arteries

Saccular Aneurysm Formation in Curved and Bifurcating Arteries AJNR Am J Neuroradiol 20:1309 1317, August 1999 Saccular Aneurysm Formation in Curved and Bifurcating Arteries George N. Foutrakis, Howard Yonas, and Robert J. Sclabassi BACKGROUND AND PURPOSE: Distinguishing

More information

Visualization and Quantification of Blood Flow in the Human Aorta. From in vivo 4D Phase Contrast MRI to Subject-Specific Computational Hemodynamics

Visualization and Quantification of Blood Flow in the Human Aorta. From in vivo 4D Phase Contrast MRI to Subject-Specific Computational Hemodynamics Visualization and Quantification of Blood Flow in the Human Aorta. From in vivo 4D Phase Contrast MRI to Subject-Specific Computational Hemodynamics Industrial Bioengineering Group Department of Mechanics,

More information

Previous talks. Clinical applications for spiral flow imaging. Clinical applications. Clinical applications. Coronary flow: Motivation

Previous talks. Clinical applications for spiral flow imaging. Clinical applications. Clinical applications. Coronary flow: Motivation for spiral flow imaging Joao L. A. Carvalho Previous talks Non-Cartesian reconstruction (2005) Spiral FVE (Spring 2006) Aortic flow Carotid flow Accelerated spiral FVE (Fall 2006) 2007? Department of Electrical

More information

Endovascular Management of Thoracic Aortic Pathology Stéphan Haulon, J Sobocinski, B Maurel, T Martin-Gonzalez, R Spear, A Hertault, R Azzaoui

Endovascular Management of Thoracic Aortic Pathology Stéphan Haulon, J Sobocinski, B Maurel, T Martin-Gonzalez, R Spear, A Hertault, R Azzaoui Endovascular Management of Thoracic Aortic Pathology Stéphan Haulon, J Sobocinski, B Maurel, T Martin-Gonzalez, R Spear, A Hertault, R Azzaoui Aortic Center, Lille University Hospital, France Disclosures

More information

Effects of Non-Newtonian Behavior of Blood on Wall Shear Stress in an Elastic Vessel with Simple and Consecutive Stenosis

Effects of Non-Newtonian Behavior of Blood on Wall Shear Stress in an Elastic Vessel with Simple and Consecutive Stenosis Biomedical & Pharmacology Journal Vol. 8(1), 123-131 (2015) Effects of Non-Newtonian Behavior of Blood on Wall Shear Stress in an Elastic Vessel with Simple and Consecutive Stenosis M. JAHANGIRI 1 *, M.

More information

ViosWorks: A Paradigm Shift in Cardiac MR Imaging

ViosWorks: A Paradigm Shift in Cardiac MR Imaging Figure 1. ViosWorks image of a patient with shunted pulmonary venous return. Image courtesy of Dr. Shreyas Vasanawala, Stanford University. ViosWorks: A Paradigm Shift in Cardiac MR Imaging The value of

More information

CT angiography techniques. Boot camp

CT angiography techniques. Boot camp CT angiography techniques Boot camp Overview Basic concepts Contrast administration arterial opacification Time scan acquisition during the arterial phase Protocol examples Helical non-gated CTA Pulmonary

More information

Asymptomatic Radiology / Clinical data Report / Cohort bias Referral bias. UCSF Vascular Symposium April 7-9, Acute Aortic Dissection

Asymptomatic Radiology / Clinical data Report / Cohort bias Referral bias. UCSF Vascular Symposium April 7-9, Acute Aortic Dissection Aortic Dissection: Natural History What is the Natural History of Aortic Dissection? UCSF Vascular Symposium April 7-9, 2011 Asymptomatic Radiology / Clinical data Report / Cohort bias Referral bias Stephen

More information

Χρόνιος διαχωρισμός. υπερηχοκαρδιογραφική. αορτής. παρακολούθηση ή άλλη; Α. Παπασπυρόπουλος ΕΠΙΜΕΛΗΤΗΣ ΓΝ.ΝΙΚΑΙΑΣ ΠΕΜΠΤΗ

Χρόνιος διαχωρισμός. υπερηχοκαρδιογραφική. αορτής. παρακολούθηση ή άλλη; Α. Παπασπυρόπουλος ΕΠΙΜΕΛΗΤΗΣ ΓΝ.ΝΙΚΑΙΑΣ ΠΕΜΠΤΗ Χρόνιος διαχωρισμός αορτής υπερηχοκαρδιογραφική παρακολούθηση ή άλλη; Α. Παπασπυρόπουλος ΕΠΙΜΕΛΗΤΗΣ ΓΝ.ΝΙΚΑΙΑΣ ΠΕΜΠΤΗ 8-2-2018 The Normal Aorta (conduit function + control ) *Aortic expansion is about

More information

3D cine PCA enables rapid and comprehensive hemodynamic assessment of the abdominal aorta

3D cine PCA enables rapid and comprehensive hemodynamic assessment of the abdominal aorta 3D cine PCA enables rapid and comprehensive hemodynamic assessment of the abdominal aorta Poster No.: C-1138 Congress: ECR 2013 Type: Scientific Exhibit Authors: M. Takahashi 1, Y. Takehara 2, H. Isoda

More information

JADAVPUR UNIVERSITY & 2 SCHOOL OF BIOSCIENCE AND ENGINEERING ABHIRUP ROY CHOUDHURY 1, KRITTIKA DASGUPTA 2, ABHIJIT CHANDA 1,2, DEBABRATA NAG 1

JADAVPUR UNIVERSITY & 2 SCHOOL OF BIOSCIENCE AND ENGINEERING ABHIRUP ROY CHOUDHURY 1, KRITTIKA DASGUPTA 2, ABHIJIT CHANDA 1,2, DEBABRATA NAG 1 Presented at the COMSOL Conference 2010 India ABHIRUP ROY CHOUDHURY 1, KRITTIKA DASGUPTA 2, ABHIJIT CHANDA 1,2, DEBABRATA NAG 1 1 DEPARTMENT OF MECHANICAL ENGINEERING & 2 SCHOOL OF BIOSCIENCE AND ENGINEERING

More information

Is it time to stent the ascending aorta? Martin Czerny

Is it time to stent the ascending aorta? Martin Czerny Is it time to stent the ascending aorta? Martin Czerny Content Basic insights into pathological process Dissection induced geometry changes Initial attempts Dedicated programme Future developments Summary

More information

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03 Introduction Cardiac Imaging Modalities Arnaud Bistoquet 12/19/03 Coronary heart disease: the vessels that supply oxygen-carrying blood to the heart, become narrowed and unable to carry a normal amount

More information

Blood Flow Simulation toward Actual Application at Hospital

Blood Flow Simulation toward Actual Application at Hospital THE 5 TH ASIAN COMPUTAITIONAL FLUID DYNAMICS BUSAN, KOREA, OCTOBER 27 ~ OCTOBER 30, 2003 Blood Flow Simulation toward Actual Application at Hospital Abstract R. Himeno 1 1. Advanced Center for Computing

More information

On the feasibility of speckle reduction in echocardiography using strain compounding

On the feasibility of speckle reduction in echocardiography using strain compounding Title On the feasibility of speckle reduction in echocardiography using strain compounding Author(s) Guo, Y; Lee, W Citation The 2014 IEEE International Ultrasonics Symposium (IUS 2014), Chicago, IL.,

More information

Four-Dimensional Aortic Blood Flow Patterns in Thoracic Aortic Grafts

Four-Dimensional Aortic Blood Flow Patterns in Thoracic Aortic Grafts Journal of Cardiovascular Magnetic Resonance@, 2(3), 201-208 (2000) Magnetic Resonance Angiography Four-Dimensional Aortic Blood Flow Patterns in Thoracic Aortic Grafts Hugo G. Bogren, Michael H. Buonocore,

More information

Assessment of Cardio- & Neurovascular Hemodynamics in the Human Circulatory System using 4D flow MRI

Assessment of Cardio- & Neurovascular Hemodynamics in the Human Circulatory System using 4D flow MRI Assessment of Cardio- & Neurovascular Hemodynamics in the Human Circulatory System using 4D flow MRI Michael Markl, Ph.D. Departments of Radiology & Biomedical Engineering Northwestern University, Chicago,

More information

Diseases of the Aorta

Diseases of the Aorta Diseases of the Aorta ASE Review 2018 Susan E Wiegers, MD, FASE, FACC Professor of Medicine My great friend Dr. Roberto Lang Disclosure None related to this presentation 1 Objectives Aneurysm Dissection

More information

Post-conditioning. P a g e 1. To my Thesis Committee,

Post-conditioning. P a g e 1. To my Thesis Committee, P a g e 1 To my Thesis Committee, This document seeks to clarify my research project. After describing what post-conditioning (PC) is, I will explain differences between my research and the recent peristaltic

More information

Non Contrast MRA. Mayil Krishnam. Director, Cardiovascular and Thoracic Imaging University of California, Irvine

Non Contrast MRA. Mayil Krishnam. Director, Cardiovascular and Thoracic Imaging University of California, Irvine Non Contrast MRA Mayil Krishnam Director, Cardiovascular and Thoracic Imaging University of California, Irvine No disclosures Non contrast MRA-Why? Limitations of CTA Radiation exposure Iodinated contrast

More information

Simulations of pulsatile blood flow in tapered S-shaped inplane and out-of-plane coronary arteries

Simulations of pulsatile blood flow in tapered S-shaped inplane and out-of-plane coronary arteries Simulations of pulsatile blood flow in tapered S-shaped inplane and out-of-plane coronary arteries Author Johnston, Barbara, Johnston, Peter Published 2009 Conference Title 18th IMACS World Congress MODSIM09

More information