Fenestrated stent grafts for the treatment of complex aortic aneurysm disease: A mature treatment paradigm

Size: px
Start display at page:

Download "Fenestrated stent grafts for the treatment of complex aortic aneurysm disease: A mature treatment paradigm"

Transcription

1 631841VMJ / X Vascular MedicineGeorgiadis et al. research-article2016 Review Article Fenestrated stent grafts for the treatment of complex aortic aneurysm disease: A mature treatment paradigm Vascular Medicine 2016, Vol. 21(3) The Author(s) 2016 Reprints and permissions: sagepub.co.uk/journalspermissions.nav DOI: / X vmj.sagepub.com George S Georgiadis 1,2, Joost A van Herwaarden 1, George A Antoniou 3, Athanasios D Giannoukas 4, Miltos K Lazarides 2 and Frans L Moll 1 Abstract The introduction of fenestrated stent grafts (SGs) to treat abdominal aortic aneurysms (AAAs) with short proximal necks began in Nowadays, the whole visceral aorta can be treated totally by endovascular means. The established use of fenestrated devices to treat complex AAAs as a first-line management option has been previously reported. An up-to-date evaluation of the literature was performed including all types of publications regarding the use of fenestrated technology to repair complex AAAs. Fenestrated repair is now an established alternative to hybrid/chimney/snorkel repairs. However, specific criteria and prerequisites are required for the use and improvement of this method. Multiple device morphologies have been used incorporating the visceral arteries in various combinations. This modular strategy connects different devices (bridging covered stents and bifurcated SGs) with the aortic main body, thus excluding the aneurysm from the circulation. Precise deployment of the fenestrated SG is mandatory for successful visceral vessel revascularization. Accurate SG sizing and customization, a high level of technical skill, and facilities with modern imaging techniques including 3D road mapping and dedicated hybrid rooms are required. Most experience has been with the custom-made Zenith Cook platform, although off-the-shelf devices have been recently implanted. More complex repairs have been performed over the last few years, but device complexity has also increased. Perioperative, mid-term, and a few recently reported long-term results are encouraging. Secondary interventions remain the main problem, similar to that observed after traditional endovascular abdominal aortic aneurysm repair (EVAR). Keywords complex aortic aneurysms, fenestrated stent grafts, endovascular, AAA Evolution of the fenestrated technology: from EVAR to stent grafts with holes and scallops Endovascular abdominal aortic aneurysm repair (EVAR) is an established alternative to open surgery for the treatment of infrarenal abdominal aortic aneurysms (AAAs). 1 Overall, its suitability is primarily affected by poor proximal and distal sealing zones and limited iliac access. 2 Short, wide or severely angulated proximal aortic necks are found to be too unfavorable to be used as a landing zone and are thought to be the most likely causes for ineligibility of EVAR. 3,4 Should these circumstances be ignored, or attempts made to extend the use of commercial infrarenal stent grafts (SGs) (Table 1) into complex anatomy, problems related to early and late failure will eventually arise. 5 For example, the shorter the non-dilated segment between the aneurysm and the lowest renal artery (what we call proximal neck), the less contact there is between an entirely infrarenal SG device, and the higher the likelihood of a type I endoleak or SG migration. 6 Besides the above-described unsuitable infrarenal neck anatomy, many patients possess aortic aneurysm changes that encroach upon the visceral region and might be 1 Department of Vascular Surgery, University Medical Center, Utrecht, The Netherlands 2 Department of Vascular Surgery, Demokritus University of Thrace, University General Hospital of Alexandroupolis, Alexandroupolis, Greece 3 Liverpool Vascular and Endovascular Service, Royal Liverpool University Hospital, Liverpool, UK 4 Department of Vascular Surgery, University of Thessaly, Larissa, Greece Corresponding author: George S Georgiadis, Department of Vascular Surgery, Demokritus University of Thrace, University General Hospital of Alexandroupolis, Alexandrou Papanastasiou 7 str., Alexandroupolis 68131, Greece. ggeorgia@med.duth.gr

2 224 Vascular Medicine 21(3) unsuitable candidates for infrarenal aortic devices. 7 Furthermore, a high percentage of them have severe comorbidities precluding traditional open repair Thus, the unmet medical needs to preserve the endovascular management of complex aortic aneurysms urged clinicians and manufactures to develop SGs with fenestrations (holes) or scallops (gaps or valleys in the upper graft fabric margin) to access visceral arteries, called fenestrated SGs, simply to allow extension of the sealing zone indefinitely, limited only by the desire to limit the number of visceral vessels incorporated into the repair. 11 When successful, fenestrated EVAR (FEVAR) leads to complete exclusion of the aneurysm while maintaining antegrade renovisceral perfusion in vital organs. Some designs are without fenestrations but with branches (pre-attached limbs or cuffs) targeted for the visceral aortic vessels, suitable for the endovascular treatment of thoracoabdominal aortic aneurysms (TAAAs). At least for short-necked and juxtarenal aortic aneurysms (JRAs), fenestrated stent-grafting technology has been shown to be feasible, with published results of highvolume experienced single centers and a few recent multicenter trials 32,33 sharing remarkable short- and midterm results, with the durability of the technique being satisfactory (technical success > 95%, low mortality rates averaging 1 2% and low rates of mid-term branch vessel occlusion averaging 4 9%) ,34 Other imaginative procedures have also been developed or modified to allow for the segmental or complete coverage of the aorta in the region of vital branches, including the chimney, snorkel, periscope and combined endovascular exclusion and extra-anatomic mesenteric/renal bypasses (hybrid visceral revascularization). 38 The objective of this paper was to provide an up-to-date review on the elective repair of perirenal and TAAAs via the FEVAR approach. Criteria and prerequisites for use and improvement of the fenestrated technology General criteria The most important indications for fenestrated SGs are listed in Table 2. 2,22,24,27,28,30,34,39 50 Owing to the normal suprarenal aortic lumen, it is generally accepted that fenestrated devices are preferably used for pararenal aneurysms (PRAs). Appropriate terminology is important when referring to FEVAR to fully understand the repair. Aortic aneurysms in the region of the renal arteries are named PRAs and further classified into juxtarenal and suprarenal types. 51 A JRA is defined as an aneurysm with a < 10 mm infrarenal aortic neck (i.e. with involvement of the aneurysmal dilatation up to the level of the renal arteries) that originates from normal aorta. 52 Although a JRA by definition is that in which the surgeon is able to place an infrarenal cross-clamp safely, a clear definition or a clear stratified classification system for JRAs does not exist, 40 especially in FEVAR studies. Donas et al. described a primary JRA as that with a short infrarenal neck < 9 mm or an aneurysmal extension to the inter-renal aorta. 40 Depending on the definition, JRAs represent almost 15% of all AAAs. 20 SRAs involve the origin of at least one renal artery and include the PRAs, which involve the renal arteries but do not extend into the superior mesenteric artery (SMA), and paravisceral aortic aneurysms, which involve the renal arteries and the SMA, but not the celiac axis. 52 Type IV TAAAs involve the origin of all four visceral arteries including the celiac axis, extending up to the diaphragmatic hiatus. 17,52,53 Other authors prefer to classify repairs based on the postoperative degree of aortic coverage. 31 Anatomical criteria Basic anatomic conditions. Generally, patients will have a survival benefit if the size of their AAA exceeds cm. 1 Slightly larger diameters are universally accepted for fenestrated repair of JRAs and paravisceral aneurysms. Indications for treatment with FEVAR include short-necked AAAs (Figure 1), JRAs, or SRAs with diameters 55 mm 2,22,30,34,39,40 in men and 50 mm 34 or > 45 mm 39 in women. Other described indications are listed in Table 1. Specific anatomic conditions. Extended basic anatomic criteria and technical issues for application of FEVAR with custom-made endografts are summarized in Table 2. 39,44,54 58 Despite the use of fenestrations which are necessary to incorporate visceral vessels bearing the desired sealing zone, a segment of relatively normal suprarenal aorta that constitutes the proximal neck is still required in fenestrated grafts. Most authors have developed a practice of establishing proximal landing zones in a region of > 2 cm parallel-walled and thrombus-free aorta and of minimal tortuosity. This is conceptually different to landing zone choice in conventional infrarenal repair, given the lack of confinement to the non-branched aorta. However, with FEVAR there is likely additional risk incurred by incorporating the entire visceral segment. Traveling up the supravisceral segment, there is concern about whether the incidence of spinal cord ischemia markedly rises. 31 Physiologic criteria Given the complexity of open aortic aneurysm repair and its complications, the application of a less invasive aortic intervention, like FEVAR, for patients deemed to be at physiological risk for open repair is intuitive. 33 The terms unfit or at high risk for open aneurysm repair patients, combined with unfavorable anatomic criteria for standard EVAR, were used as inclusion criteria in several FEVAR studies. 23,27,28,30 Significant comorbidities which were analyzed are based on Societies or National reporting guidelines. 59 The French counterpart of the US Food and Drug Administration (FDA) determined the following high-risk patient characteristics for open repair: age > 80 years; coronary artery bypass graft (CABG)/coronary stent or previous myocardial infarction (MI) with no possible coronary

3 Georgiadis et al. 225 Table 1. Available EVAR devices. a. Device (manufacturer, region) / year of FDA approval or CE mark Graft material / support / design / proximal fixation Device proximal / distal size range (in mm) Proximal / distal profile (in Fr) Accepted anatomical criteria Proximal neck diameter treatment range (in mm) Minimum proximal neck length (in mm) Maximum proximal neck angulation Iliac artery treatment diameter range (in mm) Minimum common iliac artery length (in mm) Enlarged-neck Zenith LP (Cook Medical Technologies, USA) / 2006 Talent (Medtronic Vascular, Inc., USA) / 2008 Polyester / complete stainless steel stent exoskeleton / tri-modular / suprarenal active (+ suprarenal stent with hooks) Polyester / complete nitinol stent endoskeleton / bimodular / suprarenal active (+ suprarenal stent) E-Vita (Jotek, Germany) / 2008 Polyester / complete nitinol mesh endoskeleton / bimodular / suprarenal (+ suprarenal stent) Enlarged-neck Excluder C3 (WL Gore & Associates, Inc., USA) / 2010 Endurant II (Medtronic Vascular, Inc., USA) / 2010 Enlarged-neck AFX Powerlink (Endologix, Inc., USA) / 2011 Ovation Prime (Trivascular, Inc., USA) / 2011 Fenestrated Zenith / (Cook Medical Technologies, USA) / 2012 Aorfix (Lombard Medical, UK) / 2013 Treovance (Bolton Medical, Spain) / 2013 Anaconda One-Lok (Vascutek Ltd, Scotland, UK) / 2014 eptfe / complete nitinol stent exoskeleton / bimodular / infrarenal (+ 8 pairs of anchors) Polyester / complete nitinol stent exoskeleton / bimodular / suprarenal active (+ suprarenal stent with anchor pins) Multilayer eptfe / complete elgiloy mesh endoskeleton / unibody / optional suprarenal, infrarenal (active seal) + anatomic at bifurcation PTFE, polyethylene glycol-based polymers, fluorinated ethylene propylene or nitinol / tri-modular / suprarenal (+ suprarenal stent with anchors), infrarenal (inflatable rings) Full thickness polyester / stainless steel stent exoskeleton (mid)-endoskeleton (proximal and distal) Polyester / complete internal helical circular nitinol frame / bi-modular / infrarenal (+ 4 pairs of hooks) Polyester / complete nitinol stent exoskeleton / trimodular / suprarenal infrarenal active (+ suprarenal stent with barbs and infrarenal barbs) Polyester / body unsupported limbs with internal nitinol rings structure / tri-modular / infrarenal (+ 4 pairs of hooks) Nellix (Endologix, Inc., USA) / NA Biostable in situ PEG-filled sacs / dual, cobaltchromium balloon-expandable endoframes, each surrounded by an endobag / non-modular (2 separated SGs) / infrarenal (+ PEG material that forms to seal the aneurysm sac) Incraft (Cordis Corp., USA) / NA Polyester / complete nitinol stent endoskeleton / trimodular / suprarenal (+ suprarenal stent with 8 barbs) / , 20, 22 / (b), 45 (c) / / / , 22 / 16, (c) / / 12, 14 and / , 20 / (b) / 60 (c) (if neck >15 mm) 60 (b) / 45 (c) (if neck mm) / / 14 16, 9 (d) / , 15 / 13, 14, (b) if neck 10 mm 45 (b) if neck <10 mm / , 22 / (e) (d) / / / , 19 / 15, (b) / 60 (c) (if neck (8 13 diameter) >15 mm) 60 (b) / 45 (c) (if neck 15 (14 20 diameter) mm) / , 22.5 / / 10 (excluding endobag) (blood lumen diameter < 60 mm) 5 < / / (b) / 60 (c) EVAR, endovascular aortic aneurysm repair; FDA, Food and Drug Administration; CE, Conformité Européenne; Fr, French; eptfe, expanded polytetrafluoroethylene; PEG, polyethylene glycol. a Includes also the FDA approved Zenith fenestrated system enabling treatment of short-necked and juxtarenal abdominal aortic aneurysms. b Suprarenal; c infrarenal; d contralateral; e ipsilateral.

4 226 Vascular Medicine 21(3) Table 2. Patient selection/anatomical considerations and prerequisites for use of fenestrated technology. a. General Anatomic Physiologic Surgeon and facility based JRAs, SRAs (preferably used for PRAs) or type IV TAAAs as classified by Crawford with diameter 55 mm 2,22,26,30,34,39,40 in men and 50 mm 34 or > 45 mm 39 in women or aneurysm growth > 1 cm per year 41 AAAs with short (4 12 mm, 22 8 mm, mm 26,41 or < 15 mm 42 ), non-existent, angulated b or poor quality (cone-shaped, 26,41 heavily thrombus-lined 28 ) proximal necks 24,43 precluding an adequate proximal seal with conventional EVAR devices (see Table 1) Failure of previous endovascular or open aortic aneurysm repair with the proximal or anastomotic aneurysm, respectively, involving the renal arteries 44 (para-anastomotic aneurysms of diameter 55 mm in men 27 and 50 mm in women 45 ) Type Ia endoleak not amenable to conventional repair (aortic cuff, Palmaz stenting or proximal neck reballooning), aneurysm expansion or migration after previous EVAR 45,46 Previous open 27,40,45,47 49 or endovascular 40,41,49,50 aortic surgery in patients with perirenal aneurysmal disease Aneurysm neck diameter should be no more than 42 mm Radiographically healthy proximal aorta (parallel walls, consistent diameter, free of luminal debris) and distal sealing zones of length 15 mm c Iliac arteries diameter should measure no more than 22 mm d Iliac/femoral arteries compatible with the introducer sheath (> 7 mm) e or suitable for access conduit 39 Absence of severe aortic angulation f Renal and visceral arteries intended to be perfused through the SG should have diameter > 4 mm without severe stenotic lesions g Adequate length of the target vessel to be stented 54 (renal bifurcation > 13 mm h ) 55 No multiple or important accessory renal anatomy 44 (consider intentional coverage of small accessory branches if these contribute to < 25% of both kidneys or < 40% of one kidney) 55 No excessive renal artery downward angulation or prior renal stents Termination of proximal fenestrated component mm above the aortic bifurcation 54 Sufficient fenestrated SG overlap with the bifurcated component ( 30 mm 56,57 or > 50 mm 54 ) For patients deemed to be at physiological risk for open repair Age < 85 years Hybrid rooms with advanced intraoperative imaging options as image fusion and intraoperative threedimensional rotational imaging are the best conditions for this demanding procedure JRAs, juxtarenal aortic aneurysms; SRAs, suprarenal aortic aneurysms; PRAs, pararenal aortic aneurysms; TAAAs, thoracoabdominal aortic aneurysms; AAAs, abdominal aortic aneurysms; EVAR, endovascular aortic aneurysm repair; SG, stent graft. a Manufacturing times are up to 4 8 weeks for custom-made devices; possible loss of perfect alignment of the SG to the target vessels and native aortic anatomy with off-the-shelf devices should not be overlooked. b Excessive angulation (> 60 ) poses the risk of SG malrotation/misalignment, making implantation more difficult and imperfect, adds strain into the visceral stents and may compromise the apposition between the SG fabric and the aortic wall. Furthermore, patients may be subjected to greater risk of stent fracture, dislodgment, and target vessel loss. 58 Others suggest that aortic angulation should be below 80 unless through-and-through wires and ballooning can help to advance the SGs through severe angulated anatomy. 44 c Most authors have developed a practice of establishing proximal landing zones in a region of > 2 cm parallel-walled and thrombus-free aorta and of minimal tortuosity. d Otherwise an iliac branched device would be required. e Otherwise external conduits must be created. f Aortic angulation should be below 80 unless through-and-through wires and ballooning can help to advance the SGs through severe angulated anatomy. g These can be treated before or during the fenestrated repair in high-risk open surgery patients. h This is because the shortest stent is 15 mm. revascularization; clinical symptoms of congestive heart failure (CHF); left ventricular ejection fraction (LVEF) < 40%; severe chronic obstructive lung disease (COPD), renal insufficiency (creatinine > 120 µmol/l) and hostile abdomen. 56 In other reports on FEVAR, medical high risk was also complementary based on patients anticipated to be unable to tolerate aortic cross-clamping 60 or redo surgery (abdominal 30 and/or iliac aortic repair), 40 patients with LVEF < 25%, 30,43 patients with an American Society of Anaesthesiologists (ASA) score more than 3, 40,61 or evidence of non-reconstructable cardiac ischemia. 30 Surgeon and facility-based criteria In general, FEVAR is indicated for elective cases due to the customization required for the SGs, although surgeon-modified SGs and fixed-design standardized off-the-shelf devices have been used in the acute setting 62 or for specific anatomies, respectively. 42,57,63 The surgeon/interventionalist and his tools (armamentarium) and imaging facility (operating theatre environment) are important for the FEVAR procedure. Current developments in fixed X-ray platforms enable advanced intraoperative imaging options

5 Georgiadis et al. 227 of patients (> 10,000) who underwent EVAR with commercial devices in the US between 1999 and 2008, the incidence of AAA sac enlargement after EVAR was 41% at 5 years, a rate that increased over the study period. As shown in pre-evar anatomic computed tomography (CT) imaging data, liberalization of the anatomic characteristics deemed suitable for EVAR has occurred, and several of these factors, including aortic neck diameter and aortic neck angle, were independently associated with aortic aneurysm sac enlargement, 68 which is a clinical parameter of increased risk of rupture. Patients with low compliance with EVAR guidelines had an incidence of endoleak and sac enlargement at 5 years: 32% and 41%, respectively. 68 Recently, a greater incidence of type I endoleak was documented in an off-label group of patients versus an IFU group of patients receiving the new generation Endurant II device (Medtronic Inc, Minneapolis, MN). This endoleak, identified at 1 year, persisted in this patient population up to 5 years, although there was no difference between the IFU and off-label groups as regards survival, graft thrombosis, or re-intervention rates. 69 These mid- and long-term data support a recommendation for cautious application of standard EVAR in patients outside the device-specific IFU. 69 Figure 1. Angiography of a high-risk patient with a very short-necked infrarenal abdominal aortic aneurysm, which is unsuitable for standard endovascular repair (EVAR) but suitable for fenestrated repair. such as image fusion and intraoperative three-dimensional (3D) rotational imaging. Device planning and implantation are complex, requiring advanced training and a steep learning curve. Owing to the demanding nature of the procedure, considerable debate still exists about whether fenestrated endografts should be limited to a small number of specialized centers. 64 Compelling evidence suggests that FEVAR requires appropriately dedicated teams, experience, technical infrastructure and definitely a minimum annual enrollment rate (institutional and individual practitioner rate) in order to offer acceptable results for these fragile patients. An annual threshold of complex aneurysms performed with FEVAR technology, preferably treating JRAs or PRAs with one or two fenestrations and a SMA scallop, including a few cases with proper proctoring, are necessary until a requisite level of competency is achieved. 64 Alternative options to FEVAR Off-label use of EVAR outside instructions for use Newer and more flexible SGs have marginally extended their instructions for use (IFU): proximal neck length > 10 mm when straight, or angulation < 90 where neck length is > 20 mm. 16,65 Although not considered an alternative option, in some instances the use of standard EVAR for suboptimal necks, and outside IFU of commercially available devices, has been advocated; 66,67 however, late reintervention rates are likely to be higher. 66 In a large cohort Hybrid, chimney and snorkel repairs A variety of alternative approaches have been used to extend the indications of EVAR to patients with unfavorable anatomy. 70,71 Retrograde revascularization of the visceral vessels (surgical bypass) followed by endovascular exclusion of the aortic aneurysmal site (open debranching technique) has been used, 72 but complication rates remain similar to that of open repair. 73,74 Other options include the chimney and snorkel techniques. These were first described by Greenberg et al., 35 and use commercially available devices by creating parallel channels with covered stents (CVs) to maintain renal and visceral branch perfusion and to intentionally relocate the EVAR seal zone cranially. The chimney, snorkel, periscope and sandwich grafts are cheaper than the fenestrated graft, require limited endovascular tools for implantation, and have immediate availability and broader applicability in the acute setting; 75 for example, in patients suffering from large or rapidly expanding aneurysms (> 0.5 cm/annually), emergent ruptured or symptomatic aneurysms 40 and in those who cannot withstand the time required by the manufacturer for device customization. 76 This approach, which is considered as another off-theshelf solution, can also be used as a bailout from accidental coverage of vital side branches during deployments requiring close approximation of the main body to the branch artery in question. 36,77,78 Elective indications include JRAs or aneurysms with severely angulated necks, when alternative techniques and/or devices are not options. 57 The chimney technique fundamentally differs from fenestrated and branched EVAR with regards to the relationship of the visceral stents to the aortic SG. While fenestrated and branched visceral stents are mated and sealed within integral constructs of the SG, chimney stents are positioned along the outside of the SG. Thus, the technique relies on the close

6 228 Vascular Medicine 21(3) conformation of the SG and the aortic wall around the chimney stent. The sandwich technique involves the use of CVs placed in the abdominal aorta branches, like chimneys, that are sandwiched between two aortic endografts. 75 This concept of parallel endografting, although off-label, has been popularized, but the additional seal achieved is imperfect. As such, concern remains about the effects of type I endoleak through the gutters created by the multiple side-by-side CVs outside the main endograft on long-term durability as well as branched vessel patency. 70,71 Potential strategies to nullify the gutter effect include the achievement of a ring of seal, or gasket seal, in the neck of the aneurysm (JRAs) outside the area of the parallel endografts, the use of long overlap zones (no neck aneurysms) or, more attractively, direct obliteration of the gutters ( eye of the tiger maneuver ). These adjuncts might help to improve outcomes with parallel grafts, not for only bailout situations. 79 Although technical success is high, two systematic reviews have shown that operative mortality (6% and 4.3%) and rate of type I endoleak (10% and 14%) are unquestionably high. 70,71 In anatomically matched populations undergoing open or chimney repair of JRAs or SRAs, operative mortality did not differ between groups (4.8%); however, acute kidney injury was higher in the endovascular arm (29% vs 4.8%), possibly due to planned renal artery coverage in some patients. Nonetheless, permanent dialysis occurred only in open surgery patients (9.5%). 78 In a recent comparable study with a population of 90 consecutive JRA patients, early mortality and permanent hemodialysis have been reported as higher in the endovascular arm (chimney and fenestrated repair) versus open repair arm (0% vs 6.4% and 0% vs 6.5%, respectively). 40 In another similar study (50 consecutive JRA patients undergoing fenestrated or chimney repair), early mortality did not differ between groups (8%); however, renal complications including deterioration of renal function (> 50% rise in serum creatinine) and renal infarction were considerably higher in the chimney group (25% vs 13% and 25% vs 8%, respectively). 80 In the latter study, the occurrence of early postoperative high-flow type I/III endoleaks was in favor of the fenestrated option (7.9% vs 25%). 80 Although the potential for this type of endoleak is reduced by creating two chimneys with a 20 mm seal zone length, 7 such a proximal segment endoleak is difficult to repair, and proximal extremity ballooning of the endograft with a compliant balloon or placement of a Palmaz stent may not be sufficient in the long term. 80 The high rate of complications like persistent dialysis and type I or III endoleak were also confirmed in other single-center studies for the chimney procedure (7.1% dialysis and 14% endoleak rate, respectively). 81 Available devices Fenestrated SGs are usually custom-made and significantly more expensive than standard SGs. Manufacturing that is based on precise plans of the location of the visceral arteries from CT datasets is time-consuming and may take up to 4 8 weeks. Currently, fenestrated or branched endografts are not commercially available. The Zenith Cook device (Cook Medical Inc, Bloomington, IN) formed the foundation of the fenestrated grafts in nearly all the cases, now with over 15 years of experience. It is composed of woven polyester fabric and Gianturco stainless steel stents. The top of the fabric is attached to a barbed anchor stent, while the stent below this is the high radial force sealing stent. The abdominal fenestrated Zenith SG has a composite body with an individual customized tubular proximal body (which typically contains from one to four fenestrations, depending on patient characteristics, for preservation of flow to both renals, SMA and celiac axis), a distal bifurcated body and iliac limb components. 82 The required length of the SG portion placed above the renal arteries will dictate which vessels must be incorporated in the repair as fenestrations. 83 Proximal SG components have holes in the fabric or scallops at the end of the fabric that are positioned precisely adjacent to the aortic branch artery orifices. Fenestrations are nitinol reinforced and can be constructed of varying sizes. Small fenestrations (6 6 mm, 6 8 mm) are preferably designed for the renal arteries, while larger (8, 10, or 12 mm) strut-free ones are used preferably for the SMA and celiac axis. 51 Scallops used for the celiac artery (or combined with the SMA), represent a U-shaped gap within the proximal fabric of the SG and are provided in mm widths and 6 12 mm heights depending on the device manufacturer and design. These fenestrations can be fixed in position over the ostia by deploying CVs (side branches) through the fenestrations and into the arterial branches. CVs are inserted in places where the aorta is aneurysmal, and ordinary stents are inserted in places where the aorta is of normal caliber. 84 Since 2005, more and more bare metal stents have been replaced by CVs. Almost all bridging stents used in recently published reports are balloon-expandable CVs. CVs have enhanced the applicability of endovascular options, such as the use of side branches and fenestrations apart from aortic wall, and the use of SGs without stent-supported proximal components (PCs). Scallops are intended to preserve vessel perfusion with aneurysm exclusion without the use of further bridging devices. In contrast to fenestrated SGs, branched SGs incorporate pre-attached limbs or cuffs targeted for the visceral aortic branches. 27 In fenestrated endografting, the seal occurs between the CVs and the nitinol ring of the reinforced fenestration but the seal in a branched repair is obtained between the outer wall of the CVs and the inner wall of the branch artery. 85 The Zenith system has been commercially available in the European Union (CE-marked) since late 2005 and was approved by the FDA in April Consequently, an explosive increase in FEVAR may be expected also in the USA. However, several manufacturers are in the process of developing fenestrated devices for JRAs based on their corresponding infrarenal SG platform. Results on the use of the custom-made human implant Anaconda (Vascutek, Paisley, Scotland) have been reported recently. 42 As increasingly complex aortic pathology is treated via endovascular means, innovation has been driven through the use of novel techniques and devices customized

7 Georgiadis et al. 229 in consultation with manufacturers. 75 For example, the combination of fenestrations and branches in the same proximal SG component has been used in narrow or angulated reno-visceral aortic segments, 86 or internal/external cuffs (axially oriented or caudally directed) for TAAAs and PRAs. 87 Moreover, to overcome the necessity of aortic main body customization, off-the-shelf devices have become apparent. These are fixed SG configurations, depending on the manufacturer, developed to accommodate in a wide range of aortic anatomies owing to the fact that recurrent patterns of similar arterial morphologies exist. Thus, off-the-shelf devices are applicable in predicted but not all possible anatomies (~54 88% in the literature). Currently, the main reason for their use is to treat patients with symptomatic or ruptured complex aortic aneurysms who are poor candidates for open surgical repair or have limited or no other immediate endovascular options. 88 Offthe-shelf designs are intended to treat patients with JRAs or PRAs, provided that a healthy neck exists below the SMA. Additionally, two other anatomical parameters are fundamental for the high applicability of the device: an adequate proximal neck, which is required for sealing and fixation, and the proper geometric relationship of the visceral vessels in order to provide a means of accommodating a large range of anatomies. Standard off-the-shelf devices developed for the treatment of patients with complex AAAs include the Ventana (Endologix, Irvine, CA, USA) (no longer clinically available) and p-branch (Cook Inc., Bloomington, IN, USA) systems, which can be used for the treatment of JRAs/PRAs, or for aneurysms that limit just below the SMA, respectively. The p-branch standardized device is a modular system intended to incorporate the renals with two conical pivot fenestrations and the SMA with one fixed fenestration and maintain patency to the celiac axis with a scallop. Recent reports describe up to 97% and up to 75% of neck and visceral vessel applicability using this SG. 62 Several authors have attempted to modify existing endografts to offer this technique to some patients who have no other options for aneurysm repair. 89 Of interest, 30-day mortality has been quoted as low (2%) in a recent report, suggesting that physician-modified off-the-shelf devices will definitely play a future role in the management of these complex patients. 89 Lack of quality control, inconsistent use of modifications, the potential risk of device contamination, and integrity issues that could originate from structural changes in the device are the most significant drawbacks of this practice. 88 Procedure planning Planning procedures that extend the proximal sealing zone above the renal arteries are challenging since there is little margin for error. FEVAR work-up consists of clinical examination and high-resolution contrast-enhanced spiral CT scans (slice thickness < 2 mm), which are then reconstructed in a vascular 3D workstation. Custom-made SGs are then designed on multiplanar (axial, sagittal and coronal) reconstructions and centerline of flow calculations. Essential information required includes the relationship of the aneurysm to the aortic branches and the spatial relationships between visceral vessels (including the presence and orientation of supernumerary or aberrant vessels). An appreciation of the angulations and the tortuosity, calcification, diameter and coexisting occlusive disease of the access vessels is also required. Diameters and lengths of the aorta and iliac arteries (sealing zone cross-sectional diameters, total aorta length to be covered by the SG, diameter of the aortic lumen at the level of the target vessels), and visceral vessel morphology length between the ostium of each target vessel, diameter and clock position (refers to the circumferential position related to the clock face, recorded to the quarter hour) of the origin of each target vessel are used to measure the relative positions of visceral arteries to match the fenestrations. Small, large or scalloped fenestrations (located at the uppermost portion of the fabric) are incorporated in the device design according to individualized patient anatomy. 2,56 The required length of the SG portion placed above renal arteries will dictate which vessels must be incorporated in the repair as fenestrations. 83 Details of the technique SG implantation technique has been described in more detail previously, 25,30,90 but has undergone several modifications over time. In brief (basic steps), open or percutaneous arterial access is required via both femoral arteries. In case of small and calcified external iliac arteries, a retroperitoneal approach and an iliac conduit may be required. The PC is introduced in one side (the delivery sheath of the PC has a diameter of Fr and a large (20 24 Fr) sheath is inserted on the contralateral side, each over a stiff wire. The latter is positioned just above the aortic bifurcation and after retrieval of the stiff wire three or four smaller sheaths are introduced through the large sheath valve. Through one of these sheaths, a pig-tail angiography catheter is then advanced into the aneurysm, proximal to the target vessels. 56 In some institutions, to reduce the amount of contrast medium required, branch vessels are pre-cannulated at this point to serve as markers for easier alignment of the device. 4 The PC is then advanced to the pre-planned aneurysm position and oriented with respect to branch arteries prior to unsheathing. To match the intended target vessels, not only is precise longitudinal positioning required, but correct rotational torque control of the delivery system must be applied. 46 When accurate positioning of the unsheathed SG is confirmed using small injections of contrast volume in repeated angiograms, implantation of the PC starts slowly (first two stents are deployed). This slow deployment and the partially constrained PC allows for last-minute repositioning if required, 56 taking into account that this facility to reposition the device is compromised in adverse neck angles. 82 The lumen of the distal end of the PC is then catheterized from the contralateral side and, accordingly, after over-the-wire side branch access sheath insertion (7 or 8 Fr depending on the stent diameter to be used), each target vessel is selectively cannulated through its corresponding fenestration (Figure 2). Successful catheterization is confirmed with a small amount of contrast medium injection.

8 230 Vascular Medicine 21(3) Figure 3. Fluoroscopy image of the proximal component of the stent graft: through a 7 Fr sheath, BeGraft balloon-expandable covered stents are advanced and deployed into the renal arteries. The superior mesenteric artery covered stent is in place but not yet expanded. Figure 2. With the proximal component still partially constrained, the superior mesenteric artery (SMA) and renal arteries are cannulated through the dedicated fenestrations (in this patient the stent graft has a scallop fenestration for the celiac axis). After all access sheaths are sequentially advanced to target arteries over stiff wires, appropriately sized CVs are inserted in places where the aorta is aneurysmal, and ordinary stents are inserted in places where the aorta is of normal caliber (Figure 3). 84 When all bridging stents/cvs are in place, the constrained PC is fully deployed. Prior to CVs deployment, the PC is dilated with a large compliant balloon. Using C-arm tube projections perpendicular to the fenestrations, the CVs are then deployed to their profile and flared proximally (the segment protruding into the SG lumen beyond the fenestration, usually 3 5 mm) with a balloon (10 12 mm); all maneuvers were performed after partial access sheath withdrawal (Figure 4). The procedure ends with cannulation of the PC gate permitting its connection with the bifurcated and other distal aortic components as planned (iliac extensions and/or iliac side branch devices) (Figure 5). A final angiogram confirms the absence of endoleak and patency of all SG components (Figure 6). The last steps are similar to the standard EVAR technique. Large sheaths in both femoral arteries must be removed as quickly as possible in order to avoid the occurrence of leg ischemia. Outcome measures Perioperative and late mortality Despite the theoretical advantages of FEVAR over open surgery, like the minimal invasive technique and avoidance of laparotomy and suprarenal aortic cross-clamping, investigations revealed comparable perioperative mortality rates 9,20 (with some studies reporting higher mortality with open repair). 12,91 In specialized centers, FEVAR was associated with even lower 30-day mortality rates (1% to 2.6%). 22,25,26,30,31 This compares favorably with that of open surgical repair of short-necked aneurysms, which has operative mortality rates of 2.5% to 5.8%. 92,93 Notably, in a recent meta-analysis, the mortality rate in open repair and FEVAR studies (21 and 14 studies, respectively) were exemplary and equivalent (4.1%), although a higher rate of postoperative major complications and re-interventions due to bleeding and embolic events were observed with open repair. 9 Noteworthy, greater rates of postoperative complications such as renal impairment (18.5% vs 9.8%), new onset of dialysis (3.9% vs 1.5%) and cardiac complications (11.3% vs 3.7%) were reported for open repair. 20 In a large UK registry not including less experienced centers, perioperative mortality was marginally higher (4.1%) than that reported in single-center or single-operator studies, suggesting that patient comorbidities should be taken into account. 10 Despite the fear of target vessel loss, ischemic consequences of end-organs appear to be more frequent with open repair in the early postoperative period, as shown by instances of mesenteric ischemia necessitating bowel resection and acute renal failure requiring permanent dialysis. 91 In a recent large national database, 94 FEVAR had comparable mortality to EVAR, but FEVAR was associated with an increased risk of overall complications attributed to the higher morphological complexity of an operation utilizing, for example, visceral vessel cannulation and renal stenting with attendant risks of embolization and thrombosis, lasts longer, and requires a learning curve with new technology. Pooled estimated

9 Georgiadis et al. 231 Figure 4. Flaring of the aortic portion of the left renal artery bridging covered stent is performed using the tip of a large (10 12 mm diameter) balloon catheter (A). Selective angiography of the left renal artery after covered stent placement showing good patency of the target vessel and no signs of type I or type III endoleak at this level (B). Figure 5. After all the sheaths and covered stents are in the correct place, the proximal component is fully deployed (A). Insertion of the bifurcated distal component of the stent graft from the right side (B), which is then deployed after adjustment for correct overlapping with the proximal component (C). Cannulation of the contralateral limb (C) and retrograde angiogram through the left-sided sheath showing the iliac bifurcation (D) for the correct length measurement and placement of the left iliac limb. perioperative mortality for patients undergoing fenestrated repair is 2.3%, 31 which is lower than that reported for open or endovascular repair of standard infrarenal aneurysms. Deaths because of technical errors or intraoperative complications, fortunately at the early phases of the learning curve, are not uncommon. 27,34,95 An increased duration of surgery (> 260 minutes) and postoperative events (postoperative complications, the need for dialysis and redo procedures) are strongly associated with a greater risk of 30-day and in-hospital death. 39 Mortality has also been correlated with adverse renal events, as shown in several studies. 34,96 Patients experiencing spinal cord ischemia, for example, have a 10 times greater risk of death and notably the majority of those not fully recovered die rapidly. 39 There is also evidence that outcomes are strongly correlated to the level and to the proximal extension of aneurysm disease. In a multicenter study, in-hospital mortality, combined (30-day, in-hospital) mortality and/or severe

10 232 Vascular Medicine 21(3) Figure 6. Completion angiogram after the fenestrated repair (fenestrations for the renal arteries and the SMA; scallop fenestration for the celiac axis). All visceral and renal vessels are nicely patent and no endoleak is detected. complications were strongly associated (more than double risk of death) with the aneurysm disease extension (JRAS and PRAs vs SRAs and all types of TAAAs). 39 Besides the prognostication in endovascular repair of TAAAs depending in the classical Crawford classification, there is also a trend for poorer long-term outcomes for patients treated with a device that requires coverage above the celiac artery. 31 Also, the extent of the aneurysm repair, as determined by the proximal sealing zone of the SG, is also associated with outcome. As the proximal zone of SG coverage ascends, mortality significantly increases. 97 Worse 5-year survival rates were seen with FEVAR compared to open repair (55% vs 73%) in a large meta-analysis. As stated, selection bias, higher-risks patients offered FEVAR and significantly higher secondary re-interventions rates of FEVAR might explain the decreased long-term survival. 9 Data emerged from a 12-year experience center reported decreased, survival (20%) after a mean follow-up of 8 years. This survival was negatively associated with increased age, congestive heart failure, cancer and previous aneurysm repair. Only 2% of these deaths were aortic aneurysm-related. 31 In a similar study, overall survival was 76% at 3 years and 60% at 5 years. During the 10-year study period, 54% of the patients died (9% of aneurysm related causes), an overall mortality rate which is in line with that observed in patients with peripheral vascular disease, indicating severe comorbidities in this patient group. 95 Target vessel stenosis/occlusion Target vessel occlusion still represents one of the most main complications of FEVAR. 85 Series from referral centers have included between 45 and 607 patients, with target vessels. 5,10,29,32 34,39,80,97 Up to July 2012, a total of 2463 target vessels have been accessed through fenestrations and/or scallops, all within the use of the fenestrated Zenith SG. 20 Overall, early target vessel patency rate ranges from 90.5% to 99.7%. 33 The published 1-year target vessel patency rates ranges from 90.5% to 97%. 12 Recently pooled estimates of vessel patency at completion angiogram and in the long-term (5 years) during follow-up were reported 98.2% and 95.8%, respectively. 9 Verhoeven et al., reported a cumulative visceral target vessel patency (275 target vessels in 100 patients) of 93.3% at 5 years. 22 However, stent patency of target vessels must be differentiated from target vessel patency and was reported 95.7% at 1 year and 88.6% at 4 years. 34 In-stent-visceral stenosis/occlusion can be catastrophic with serious clinical sequelae (death, lifelong dialysis, bowel ischemia). Stenting of a fenestration is mandatory to avoid early visceral artery occlusion. Scallops are generally not stented. 22 Cannulating target vessels followed by tracking sheaths and CVs can be challenging when doing a FEVAR. Unsuccessful catheterization/stenting and visceral vessel loose is reported rather low despite the more complexity of FEVAR compared to standard EVAR. Important factors contributing to technical failure include the inadequate device design and suboptimal procedure planning. 86 Intraoperative technical failure was reported only 1.1% and 2.1% by Verhoeven et al. 22 and by Mastracci et al., 31 suggesting that expertise is of paramount importance. Renal issues One concern regarding FEVAR is the potential of negative effect on renal function. Postoperative renal impairment was not rare in a multicenter trial (18%) 39 and in a literature review (22.2%), 17 and was mostly observed in patients with PAOD, long-lasting operations and complex cases. 39 Moreover, the risk for adverse renal events was 16% in patients without preoperative renal dysfunction and 39% in patients with preoperative renal dysfunction. 96 In other studies, transient as well as permanent post-procedural renal impairment was not influenced by preoperative renal status. 34 If the high prevalence of renal insufficiency of the patient population prior to treatment of aneurysms that involve or abut the renal arteries is a stronger contributing factor, remains to be determined. Notably, Rao et al., reported that preoperative renal dysfunction is rather common in patients with JRAs scheduled for FEVAR (6 44% in all 13 included studies, > 10% in 8/13 studies). 9 High incidence of renal insufficiency has been reported in patients with AAAs (up to 25%); however, no correlation with greater risk of failure of primary EVAR has been found. In contrast, an increased tendency for FEVAR failure in those patients with renal insufficiency has been reported. 46 The primary reason for renal deterioration or transient/ permanent dialysis is renal artery thrombosis after failed catheterization of this target vessel. 33 The renal artery as a target vessel was strongly correlated with perioperative vessel related events (technical failure, vessel injuries and early occlusions). 86 Renal insults not requiring hemodialysis, such as iatrogenic arteriovenous fistula, perinephric

11 Georgiadis et al. 233 hemorrhages and small infarcts to the renal pole, are not uncommon. 21,82,98 Postoperative evolution of estimated glomerular filtration rate (egfr) has been reported in a few studies. In the French multicenter trial (n = 134 patients), renal function showed a significant improvement or remained stable in 90% of patients and hemodialysis, either temporary or permanent, was required in 4.5%. 33 Renal dysfunction is prevalent also after open repair techniques. Long-term survival after open repair of infrarenal AAAs decreases from 51% to only 12% at 10 years in the setting of the presence or absence of post-procedural renal dysfunction. 96 Short-term mean endovascular postoperative egfr and serum creatinine values were presented significantly lower compared to those obtained after open surgical repair. 40 The avoidance of suprarenal clamping and ischemia possibly explains the excellent results of the endovascular arm (FEVAR and chimney EVAR) in comparable studies with open surgical repair (0 vs 6.5% requirement of persistent dialysis). 40 In contrast to these results, a recent well-conducted meta-analysis reported similar perioperative mortality rates (30-day and in-hospital) between open and endovascular repair of juxtarenal aneurysms (4.1%). Similarly, pooled proportions for postoperative renal insufficiency and permanent dialysis were not statistically different (13.9% vs 11.4% and 2.8% vs 1.9%, respectively). However, secondary interventions were more and long-term survival was lower (at a statistically significant level) in FEVAR compared to open repair (pooled event rate 12.7% vs 4.9% and survival rate 55% vs 73%). Furthermore, more FEVAR patients developed renal impairment during follow-up than open repair patients (19.7% vs 7.7%, p < ), suggesting that apart from possible higher preoperative comorbidities and heterogenous reporting of renal outcomes, repeat interventions and contrast nephropathy from utilization of CT angiography surveillance at short intervals might play a role in this progressive renal damage. 9 Type I and type III endoleaks Like standard EVAR, successful aneurysm exclusion should follow any fenestrated endograft implanted in the perirenal position without any type I or III endoleaks (failure of graft/aorta or branch stent/branch artery wall interface (e.g. branch stent dislocation from poor apposition of branch walls) or failure of device device interface, respectively (either from PC/branch stent, branch stent/branch stent, PC/bifurcated device or bifurcated device/limb extension component separation or from branch stent/branch stent fracture)) at completion angiogram. Failure to obtain an adequate seal between the various SG modular components and the arterial wall may lead to continuous pressurization of the aneurysm sac and subsequent rupture. Sealing zone failure in EVAR has been related to morphologic factors such as neck angulation, short neck, conical geometry, excessive calcium burden, 66 and non-adherence to device instructions for repairs. 68 However, within FEVAR, the physician has the opportunity to customize more proximal and longer sealing zones, thus removing the anatomical barrier of the visceral aorta. 99 Although more complex, higher than juxtarenal repairs to achieve healthier sealing zones correspond to lower endoleak rates, 99 despite the greater risk of spinal cord ischemia with increasing graft coverage above the celiac artery, and the greater risk of celiac occlusion with supraceliac landing zones. 31 Parallelwalled aortas are more protective against proximal endoleaks than non-cylindrical shaped aortas. 99 Proximal endoleaks detected at the operative room can be corrected with ancillary procedures, usually with the insertion of a Palmaz stent. However, their occurrence is considered a bad prognostic sign for the durability of the repair, as many of them, regardless of the immediate success, usually recur during follow-up. 99 The rates of early types I and III endoleak were 5.8% and 2.6%, respectively, and the rates of late endoleaks were 2.2% and 3.2% in the latest meta-analysis on FEVAR versus open repair. 9 Overall, and in a recent large data (607 patients receiving four design devices), the rates of types I, II and III endoleak through the entire follow-up period (mean = 8 years) were 3%, 16% and 4.6%, respectively. Notably, a higher incidence of type I endoleak was observed in patients receiving device configurations with only renal fenestrations, suggesting that sealing in the mid-visceral aorta, with a shorter length of aorta coverage, jeopardizes the stability of the proximal SG. 31 A high percentage of endoleaks eventually require redo operations, which puts into question the longevity of the repair. 28,31 Regular CT examinations are required to adjudicate the absence of endoleaks. Not all patients demonstrate shrinkage of the aneurysm sac during follow-up. Aneurysm diameter changes after FEVAR are considered significant when 5 mm. Aneurysm diameter decreased 5 mm in 39% of patients at 12 months, 64% at 36 months and 71% at 60 months in a recent study with a mean follow-up of 67 months. 95 Endograft migration Migration in infrarenal EVAR has been classified as any movement > 10 mm or that caused symptoms or required re-intervention. There is little detailed information regarding migration in fenestrated SGs in the literature. Early identification of any migration is crucial. This early recognition of device instability gives the physician the opportunity to intervene early and avert any serious clinical sequelae. 100 The main concerns are blood flow compromise to target vessels and loss of an aortic seal leading to aneurysm reperfusion. Noteworthy, only those cases complicated by serious clinical events or requiring re-intervention are reported in the literature. Migration rates between 1% and 7% have been reported, 25,29 or higher in other studies, all requiring re-interventions. 85 Previous evaluation confirmed that insufficient landing zone or imprecise planning of the procedure could explain most of the adverse events, including migrations/ type I endoleak with or without visceral stent fractures. 85 England et al. 100 pointed out that protective contributing factors to a low incidence of migration rates in FEVAR include barbs, higher fixation of SG fabric, bare proximal stent struts and a separate proximal component. Technical

Access More Patients. Customize Each Seal.

Access More Patients. Customize Each Seal. Access More. Customize Each Seal. The Least Invasive Path Towards Proven Patency ULTRA LOW PROFILE TO EASE ADVANCEMENT The flexible, ultra-low 12F ID Ovation ix delivery system enables you to navigate

More information

FEVAR FIFTEEN YEARS OF EFFICIENCY E.DUCASSE MD PHD FEBVS CHU DE BORDEAUX

FEVAR FIFTEEN YEARS OF EFFICIENCY E.DUCASSE MD PHD FEBVS CHU DE BORDEAUX FEVAR FIFTEEN YEARS OF EFFICIENCY E.DUCASSE MD PHD FEBVS CHU DE BORDEAUX 2018 A BIT OF HISTORY First use of F-EVAR : 1990s Park et al. J Vasc Interv Radiol. 1996;7:819-823. Faruqi et al. J Endovasc Surg.

More information

Optimizing Accuracy of Aortic Stent Grafts in Short Necks

Optimizing Accuracy of Aortic Stent Grafts in Short Necks Optimizing Accuracy of Aortic Stent Grafts in Short Necks Venkatesh Ramaiah, MD, FACS Medical Director Arizona Heart Hospital Director Peripheral Vascular and Endovascular Research Arizona Heart Institute

More information

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully Physician Training Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully supported by self-expanding z-stents H&L-B

More information

Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System,

Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System, Young-Guk Ko, M.D., Dangas G, J Am Coll Cardiol Intv 2012;5:1071 All-cause Mortality Dangas Severance G, J Am Coll Cardiovascular Cardiol Intv Hospital, 2012;5:1071 Yonsei University Health System Aneurysm-related

More information

Robert F. Cuff, MD FACS SHMG Vascular Surgery

Robert F. Cuff, MD FACS SHMG Vascular Surgery Robert F. Cuff, MD FACS SHMG Vascular Surgery Objectives To become familiar with the commercially available fenestrated EVAR graft Discuss techniques to increase success Review available data to determine

More information

Talent Abdominal Stent Graft

Talent Abdominal Stent Graft Talent Abdominal with THE Xcelerant Hydro Delivery System Expanding the Indications for EVAR Treat More Patients Short Necks The Talent Abdominal is the only FDA-approved device for proximal aortic neck

More information

Current Status of EVAR for Infrarenal AAA. 31 st Annual Florida Vascular Society. PENN Surgery

Current Status of EVAR for Infrarenal AAA. 31 st Annual Florida Vascular Society. PENN Surgery Current Status of EVAR for Infrarenal AAA 31 st Annual Florida Vascular Society PENN Surgery No Disclosures Stent Grafts Design Related Differences What really matters? Modular Unibody Supported Unsupported

More information

Conflicts of Interest. When and Why Complex EVAR in Tx of juxta/suprarenal AAA? Summary. Infrarenal EVAR for short necks 2y postop

Conflicts of Interest. When and Why Complex EVAR in Tx of juxta/suprarenal AAA? Summary. Infrarenal EVAR for short necks 2y postop When and Why Complex EVAR in Tx of juxta/suprarenal AAA? Tim Resch MD Vascular Center Skane University Hospital Conflicts of Interest COOK Medical - Consulting, Speakers Bureau, IP, Research support Medtronic

More information

Nellix Endovascular System: Clinical Outcomes and Device Overview

Nellix Endovascular System: Clinical Outcomes and Device Overview Nellix Endovascular System: Clinical Outcomes and Device Overview Jeffrey P. Carpenter, MD Professor and Chief, Department of Surgery CAUTION: Investigational device. This product is under clinical investigation

More information

A New EVAR Device for Infrarenal AAAs

A New EVAR Device for Infrarenal AAAs A New EVAR Device for Infrarenal AAAs Peter Nelson, MD, MS Assistant Professor of Surgery MM0203 Rev. 01 Current U.S. EVAR Devices Anatomical Fixation Proximal Fixation Powerlink - Endologix Excluder WL

More information

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ History of the Powerlink System Design and Clinical Results Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ Powerlink System: Unibody-Bifurcated Design Long Main Body Low-Porosity Proprietary eptfe

More information

Hostile Proximal Neck: A New Conformable EVAR Device

Hostile Proximal Neck: A New Conformable EVAR Device Hostile Proximal Neck: A New Conformable EVAR Device Young-Guk Ko, M.D., Seoul, Korea Currently Available Devices for EVAR in Korea, 2018 Zenith Flex, Cook Endurant IIs, Medtronic INCRAFT, Cordis AFX2,

More information

Cook Medical. Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training

Cook Medical. Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training Cook Medical Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full-thickness,

More information

TriVascular Ovation Prime Abdominal Stent Graft System

TriVascular Ovation Prime Abdominal Stent Graft System TriVascular Ovation Prime Abdominal Stent Graft System Science of the Seal O-Ring Sealing Technology O-Ring Sealing in Proven Engineering Solutions O-rings are designed to seal by blocking the flow of

More information

Current Status of Abdominal Aortic Stent Grafts. John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center

Current Status of Abdominal Aortic Stent Grafts. John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center Current Status of Abdominal Aortic Stent Grafts John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center Autumn Greetings Disclosure Statement of Financial Interest Within

More information

How to select FEVAR versus EVAR + endoanchors in short-necked AAAs

How to select FEVAR versus EVAR + endoanchors in short-necked AAAs How to select FEVAR versus EVAR + endoanchors in short-necked AAAs Jean-Paul P.M. de Vries, Richte C.L. Schuurmann St. Antonius Hospital Nieuwegein, The Netherlands 21st Critical Issues Congress Nuernberg,

More information

Aortic stents, types, selection, tricks in deployment.

Aortic stents, types, selection, tricks in deployment. Aortic stents, types, selection, tricks in deployment. Hamdy Soliman.M.D,FSCAI Consultant of Cardiology&Head of Endovascular Unit National Heart Institute Endovascular Treatment of Thoracic Aortic Aneurysms

More information

My personal experience with INCRAFT in standard and challenging cases

My personal experience with INCRAFT in standard and challenging cases My personal experience with INCRAFT in standard and challenging cases G Pratesi, MD Vascular Surgery University of Rome Tor Vergata giovanni.pratesi@uniroma2.it Disclosure Speaker name: Giovanni Pratesi,

More information

The Ventana Off-the-Shelf Graft for Pararenal AAA. Andrew Holden Associate Professor of Radiology Auckland Hospital

The Ventana Off-the-Shelf Graft for Pararenal AAA. Andrew Holden Associate Professor of Radiology Auckland Hospital The Ventana Off-the-Shelf Graft for Pararenal AAA Andrew Holden Associate Professor of Radiology Auckland Hospital Disclosures Andrew Holden, MBChB, FRANZCR Investigator in Nellix and Ventana Trials Clinical

More information

Abdominal and thoracic aneurysm repair

Abdominal and thoracic aneurysm repair Abdominal and thoracic aneurysm repair William A. Gray MD Director, Endovascular Intervention Cardiovascular Research Foundation Columbia University Medical Center Abdominal Aortic Aneurysm Endografts

More information

ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients

ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients The Ovation System is approved to treat infrarenal abdominal aortic aneurysms and is not

More information

LOWERING THE PROFILE RAISING THE BAR

LOWERING THE PROFILE RAISING THE BAR LOWERING THE PROFILE RAISING THE BAR INNOVATIVE LOW PROFILE. ADVANCED CLINICAL PERFORMANCE. The AFX TM Endovascular AAA System integrates anatomical fixation with an advanced delivery system and graft

More information

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up Zenith Renu AAA Converter Graft Device Description Planning and Sizing Deployment Sequence Patient Follow-Up Device description: Device indications The Zenith Renu AAA Converter Graft with Z-Trak Introduction

More information

INCRAFT system: Update from the Pivotal INSPIRATION Study

INCRAFT system: Update from the Pivotal INSPIRATION Study INCRAFT system: Update from the Pivotal INSPIRATION Study Michel S. Makaroun MD Co-Director, UPMC Heart and Vascular Institute Professor and Chair, Division of Vascular Surgery University of Pittsburgh

More information

Challenges. 1. Sizing. 2. Proximal landing zone 3. Distal landing zone 4. Access vessels 5. Spinal cord ischemia 6. Endoleak

Challenges. 1. Sizing. 2. Proximal landing zone 3. Distal landing zone 4. Access vessels 5. Spinal cord ischemia 6. Endoleak Disclosure I have the following potential conflicts of interest to report: Consulting: Medtronic, Gore Employment in industry Stockholder of a healthcare company Owner of a healthcare company Other(s)

More information

Taming The Aorta. David Minion, MD Program Director, Vascular Surgery University of Kentucky Medical Center Lexington, Kentucky, USA

Taming The Aorta. David Minion, MD Program Director, Vascular Surgery University of Kentucky Medical Center Lexington, Kentucky, USA Taming The Aorta David Minion, MD Program Director, Vascular Surgery University of Kentucky Medical Center Lexington, Kentucky, USA Faculty Disclosure Consulting: Endologix, Cook 1 Objectives Review the

More information

When to use standard EVAR with EndoAnchors or CHEVAR in short-neck AAAs LINC ASIA 18

When to use standard EVAR with EndoAnchors or CHEVAR in short-neck AAAs LINC ASIA 18 When to use standard EVAR with EndoAnchors or CHEVAR in short-neck AAAs JEAN-PAUL P.M. DE VRIES, DIRECTOR OF VASCULAR SURGERY ST.ANTONIUS HOSPITAL NIEUWEGEIN, THE NETHERLANDS. LINC ASIA-PACIFIC HongKong,

More information

Lessons learned from Ch-EVAR for the treatment of. Miltos Matsagkas MD, PhD, FEBVS Professor of Vascular Surgery University of Thessaly

Lessons learned from Ch-EVAR for the treatment of. Miltos Matsagkas MD, PhD, FEBVS Professor of Vascular Surgery University of Thessaly Lessons learned from Ch-EVAR for the treatment of pararenal AAAs Miltos Matsagkas MD, PhD, FEBVS Professor of Vascular Surgery University of Thessaly Ch-EVAR Ch-EVAR = Chimney-EVAR Placement of single

More information

Endovascular Repair o Abdominal. Aortic Aneurysms. Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida

Endovascular Repair o Abdominal. Aortic Aneurysms. Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida Endovascular Repair o Abdominal Aortic Aneurysms Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida Disclosure Nothing to disclose. 2 Mr. X AAA Mr. X. Is a 70 year old male who presented to

More information

Technology. The introduction of endovascular aortic repair. cover story

Technology. The introduction of endovascular aortic repair. cover story Infrarenal EVAR Technology Review Steady evolution in device design and delivery has expanded endovascular repair to more patients, but further advancements are integral to this technology s future. By

More information

Ovation. Sean Lyden, MD Department Chair, Vascular Surgery Cleveland Clinic

Ovation. Sean Lyden, MD Department Chair, Vascular Surgery Cleveland Clinic Ovation Sean Lyden, MD Department Chair, Vascular Surgery Cleveland Clinic Disclosure Statement of Financial Interest Within the past 12 months, I or my spouse/partner have had a financial interest/arrangement

More information

Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC

Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC Interventional Cardiologist/Endovascular Specialist Bradenton Cardiology Center Bradenton, FL, USA Disclosures

More information

GORE EXCLUDER AAA Endoprosthesis ANNUAL CLINICAL UPDATE OCTOBER Section I Clinical experience. Section II Worldwide commercial experience

GORE EXCLUDER AAA Endoprosthesis ANNUAL CLINICAL UPDATE OCTOBER Section I Clinical experience. Section II Worldwide commercial experience GORE EXCLUDER AAA Endoprosthesis ANNUAL CLINICAL UPDATE OCTOBER 2018 Abstract This annual clinical update provides a review of the ongoing experience with the GORE EXCLUDER AAA Endoprosthesis used in the

More information

Endovascular Treatment of the Aorta with Fenestrated and Branched Grafts

Endovascular Treatment of the Aorta with Fenestrated and Branched Grafts Endovascular Treatment of the Aorta with Fenestrated and Branched Grafts Eric LG Verhoeven,MD, PhD, A. Katsargyris, MD Vascular and Endovascular Surgery, Paracelsus Medical University, Nuremberg, Germany

More information

Challenging anatomies demand versatility.

Challenging anatomies demand versatility. Challenging anatomies demand versatility. The Distinct Advantages of Separating Seal and Fixation ANATOMICAL FIXATION Unlike proximal fixation designs, the AFX bifurcated unibody endograft allows for natural

More information

Case Report A Case of Successful Coil Embolization for a Late-Onset Type Ia Endoleak after Endovascular Aneurysm Repair with the Chimney Technique

Case Report A Case of Successful Coil Embolization for a Late-Onset Type Ia Endoleak after Endovascular Aneurysm Repair with the Chimney Technique Case Reports in Vascular Medicine Volume 2016, Article ID 5307416, 4 pages http://dx.doi.org/10.1155/2016/5307416 Case Report A Case of Successful Coil Embolization for a Late-Onset Type Ia Endoleak after

More information

Off-the-Shelf Devices. Mark A Farber, MD FACS Director, Aortic Center Professor of Radiology and Surgery University of North Carolina

Off-the-Shelf Devices. Mark A Farber, MD FACS Director, Aortic Center Professor of Radiology and Surgery University of North Carolina Off-the-Shelf Devices Mark A Farber, MD FACS Director, Aortic Center Professor of Radiology and Surgery University of North Carolina Disclosures Cook - Research Support, Consultant, Clinical Trials WL

More information

Right Choice for Right Angles

Right Choice for Right Angles Right Choice for Right Angles The Anatomy of Technology Aorfix gives you technology that conforms to patient anatomy, optimising both procedure and post-operative performance. Fishmouth for optimum neck

More information

How to Categorize the Infrarenal Neck Properly? I Van Herzeele Dept. Thoracic and Vascular Surgery, Ghent University, Belgium

How to Categorize the Infrarenal Neck Properly? I Van Herzeele Dept. Thoracic and Vascular Surgery, Ghent University, Belgium How to Categorize the Infrarenal Neck Properly? I Van Herzeele Dept. Thoracic and Vascular Surgery, Ghent University, Belgium Disclosure Speaker name: Isabelle Van Herzeele I have the following potential

More information

Ancillary Components with Z-Trak Introduction System

Ancillary Components with Z-Trak Introduction System Ancillary Components with Z-Trak Introduction System Zenith Flex AAA Endovascular Graft Ancillary Components Converter Converters can be used to convert a bifurcated graft into an aortouniiliac graft if

More information

FROM THE EVERYDAY TO THE EXTRAORDINARY

FROM THE EVERYDAY TO THE EXTRAORDINARY FROM THE EVERYDAY TO THE EXTRAORDINARY Created with the collaboration of more than 250 physicians around the world, ENDURANT empowers you to create stronger outcomes for more patients, including those

More information

Durability of The Endurant Stent-Graft through 5 Years

Durability of The Endurant Stent-Graft through 5 Years Durability of The Endurant Stent-Graft through 5 Years Michel S. Makaroun MD Co-Director, UPMC Heart and Vascular Institute Professor and Chair, Division of Vascular Surgery University of Pittsburgh School

More information

Percutaneous Approaches to Aortic Disease in 2018

Percutaneous Approaches to Aortic Disease in 2018 Percutaneous Approaches to Aortic Disease in 2018 Wendy Tsang, MD, SM Assistant Professor, University of Toronto Toronto General Hospital, University Health Network Case 78 year old F Lower CP and upper

More information

COMBINED TECHNIQUE CHIMNEY + FENESTRATED ENDOGRAFT FOR COMPLEX ANEURYSMS ERIC DUCASSE - MD PHD FEVBS CHU BORDEAUX

COMBINED TECHNIQUE CHIMNEY + FENESTRATED ENDOGRAFT FOR COMPLEX ANEURYSMS ERIC DUCASSE - MD PHD FEVBS CHU BORDEAUX COMBINED TECHNIQUE CHIMNEY + FENESTRATED ENDOGRAFT FOR COMPLEX ANEURYSMS ERIC DUCASSE - MD PHD FEVBS CHU BORDEAUX DISCLOSURE SPEAKER NAME: PR. E. DUCASSE I HAVE THE FOLLOWING POTENTIAL CONFLICTS OF INTEREST

More information

Jean M Panneton, MD Professor of Surgery Program Director Vascular Surgery Chief EVMS. Arch Pathology: The Endovascular Era is here

Jean M Panneton, MD Professor of Surgery Program Director Vascular Surgery Chief EVMS. Arch Pathology: The Endovascular Era is here Jean M Panneton, MD Professor of Surgery Program Director Vascular Surgery Chief EVMS Arch Pathology: The Endovascular Era is here Disclosures Consultant: Cook Medical, Bolton Medical, Medtronic Inc, Volcano,

More information

14F OD Ovation Abdominal Stent Graft System

14F OD Ovation Abdominal Stent Graft System 14F OD Ovation Abdominal Stent Graft System 2 Year Results from the European Study Dierk Scheinert, MD Center for Vascular Medicine Angiology and Vascular Surgery Park Hospital Leipzig, Germany Disclosure

More information

Durable outcomes. Proven performance.

Durable outcomes. Proven performance. Durable outcomes. Proven performance. GORE EXCLUDER AAA Endoprosthesis GORE EXCLUDER Iliac Branch Endoprosthesis GORE EXCLUDER AAA Endoprosthesis The most-studied* EVAR stent graft designed for durable

More information

Increased Flexibility of AneuRx Stent-Graft Reduces Need for Secondary Intervention Following Endovascular Aneurysm Repair

Increased Flexibility of AneuRx Stent-Graft Reduces Need for Secondary Intervention Following Endovascular Aneurysm Repair 583 Increased Flexibility of AneuRx Stent-Graft Reduces Need for Secondary Intervention Following Endovascular Aneurysm Repair Frank R. Arko, MD; W. Anthony Lee, MD; Bradley B. Hill, MD; Paul Cipriano,

More information

EndoVascular Aneurysm Sealing (EVAS) with Nellix

EndoVascular Aneurysm Sealing (EVAS) with Nellix 1 2 EndoVascular Aneurysm Sealing (EVAS) with Nellix Designed to seal entire aneurysm with contained biostable polymer Non-modular design with complete fixation Expands endovascular patient eligibility

More information

Ventana Fenestrated Stent-Graft System for Endovascular Repair of Juxtarenal Aortic Aneurysms

Ventana Fenestrated Stent-Graft System for Endovascular Repair of Juxtarenal Aortic Aneurysms J ENDOVASC THER 173 TECHNICAL NOTE Ventana Fenestrated Stent-Graft System for Endovascular Repair of Juxtarenal Aortic Aneurysms Renato Mertens, MD; Michel Bergoeing, MD; Leopoldo Mariné, MD; Francisco

More information

Hostile Neck During EVAR, The Role Of Endoanchores

Hostile Neck During EVAR, The Role Of Endoanchores Hostile Neck During EVAR, The Role Of Endoanchores Samer Koussayer, MD, FACS, RVT Prof, Al Faisal University Section Head and consultant Vascular & Endovascular Surgery Division King Faisal Specialist

More information

Arch Repair with the Bolton Medical RelayBranch Thoracic Stent-graft system: Multicenter experience

Arch Repair with the Bolton Medical RelayBranch Thoracic Stent-graft system: Multicenter experience Arch Repair with the Bolton Medical RelayBranch Thoracic Stent-graft system: Multicenter experience Joost van Herwaarden, MD, PhD University Medical Center, Utrecht Disclosure I have the following potential

More information

ChEVAR Vs. fevar for juxtarenal Aneurysm. E.Ducasse MD PhD FEVBS Unit of vascular surgery CHU bordeaux

ChEVAR Vs. fevar for juxtarenal Aneurysm. E.Ducasse MD PhD FEVBS Unit of vascular surgery CHU bordeaux ChEVAR Vs. fevar for juxtarenal Aneurysm E.Ducasse MD PhD FEVBS Unit of vascular surgery CHU bordeaux CH-EVAR VS. F-EVAR IN JAAAs Meta-analysis, 2001-2012 5 CH-EVAR studies (94 patients, 151 target vessels)

More information

Endoleaks after F-BEVAR How to Assess & Treat? Gustavo S. Oderich, MD Mayo Clinic Rochester, MN

Endoleaks after F-BEVAR How to Assess & Treat? Gustavo S. Oderich, MD Mayo Clinic Rochester, MN Endoleaks after F-BEVAR How to Assess & Treat? Gustavo S. Oderich, MD Mayo Clinic Rochester, MN FACULTY DISCLOSURE Gustavo S. Oderich MD Consulting, DSMB, CEC* Cook Medical Inc., WL Gore, Lombardi Honoraria

More information

Residual Dissection and False Lumen Aneurysm After TEVAR

Residual Dissection and False Lumen Aneurysm After TEVAR WHAT WOULD YOU DO? Residual Dissection and False Lumen Aneurysm After MODERATOR: MARK FARBER, MD PANEL: YAZAN DUWAYRI, MD; MATTHEW J. EAGLETON, MD; WILLIAM D. JORDAN Jr, MD; TILO KÖLBEL, MD, PhD; AND ERIC

More information

Obesity, Scaring, Access in EVAR. Kiskinis D, Melas N, Ktenidis K. 1 st Department of Surgery Aristotle University of Thessaloniki, Greece

Obesity, Scaring, Access in EVAR. Kiskinis D, Melas N, Ktenidis K. 1 st Department of Surgery Aristotle University of Thessaloniki, Greece Obesity, Scaring, Access in EVAR Kiskinis D, Melas N, Ktenidis K. 1 st Department of Surgery Aristotle University of Thessaloniki, Greece Obesity Decreased radiolucency (visibility) Max weight load < 160

More information

The clinical update for the Zenith AAA Endovascular Graft has included results from the Zenith AAA Endovascular Graft multi-center clinical study,

The clinical update for the Zenith AAA Endovascular Graft has included results from the Zenith AAA Endovascular Graft multi-center clinical study, The clinical update for the Zenith AAA Endovascular Graft has included results from the Zenith AAA Endovascular Graft multi-center clinical study, the 36 mm diameter Zenith Flex AAA Endovascular Graft

More information

EVAR Revision Setting - How can Heli-FX EndoAnchors improve the outcomes?

EVAR Revision Setting - How can Heli-FX EndoAnchors improve the outcomes? D. Böckler Department of Vascular and Endovascular Surgery University Hospital Heidelberg EVAR Revision Setting - How can Heli-FX EndoAnchors improve the outcomes? Disclosures Speaker name: Dittmar Böckler

More information

Treatment of Thoracoabdominal Aneurysms Is there a need for custom-made devices?

Treatment of Thoracoabdominal Aneurysms Is there a need for custom-made devices? : FETURED TECHNOLOGY: JOTEC E-XTR DESIGN ENGINEERING Treatment of Thoracoabdominal neurysms Is there a need for custom-made devices? INTERVIEW ND CSE PRESENTTIONS WITH DNIEL RNZN, MD, ND NDREJ SCHMIDT,

More information

Degeneration of the Neck Post Implementation - a New Era of AAA Stent

Degeneration of the Neck Post Implementation - a New Era of AAA Stent Degeneration of the Neck Post Implementation - a New Era of AAA Stent New Mexico Heart Institute Albuquerque, New Mexico USA - Gore Current FDA-Approved EVAR Devices Sealing Mechanism Endologix Lombard

More information

Patient selection in Hostile Necks and how. to prevent endoleaks a word of caution

Patient selection in Hostile Necks and how. to prevent endoleaks a word of caution Patient selection in Hostile Necks and how to prevent endoleaks a word of caution P M Kasprzak, K. Pfister Department of Vascular Surgery Endovascular Surgery University Hospital Regensburg, Germany Conflict

More information

Anatomical challenges in EVAR

Anatomical challenges in EVAR Anatomical challenges in EVAR M.H. EL DESSOKI, MD,FRCS PROFESSOR OF VASCULAR SURGERY CAIRO UNIVERSITY Disclosure Speaker name:... I have the following potential conflicts of interest to report: Consulting

More information

Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment

Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment Robert Y. Rhee, MD Chief, Vascular and Endovascular Surgery Director, Aortic Center Maimonides Medical Center Brooklyn,

More information

Influence of patient selection and IFU compliance on outcomes following EVAS

Influence of patient selection and IFU compliance on outcomes following EVAS Influence of patient selection and IFU compliance on outcomes following EVAS LUNCH SYMPOSIUM LINC 2017 Jan MM Heyligers, MD, PhD, FEBVS Consultant Vascular Surgeon Elisabeth TweeSteden Hospital Tilburg,

More information

No Neck Is Needed! Treat the Aneurysm Instead! Andrew Holden, MD Associate Professor of Radiology Auckland City Hospital

No Neck Is Needed! Treat the Aneurysm Instead! Andrew Holden, MD Associate Professor of Radiology Auckland City Hospital No Neck Is Needed! Treat the Aneurysm Instead! Andrew Holden, MD Associate Professor of Radiology Auckland City Hospital Disclosures Andrew Holden, MBChB, FRANZCR No financial investment to disclose Investigator

More information

Aortic Neck Issues Associated Clinical Sequelae/Implications for Graft Choice

Aortic Neck Issues Associated Clinical Sequelae/Implications for Graft Choice Aortic Neck Issues Associated Clinical Sequelae/Implications for Graft Choice Eric Verhoeven, MD, PhD, A. Katsargyris, MD Department of Vascular and Endovascular Surgery, Paracelsus Medical University,

More information

EVAR replaced standard repair in most cases. Why?

EVAR replaced standard repair in most cases. Why? EVAR replaced standard repair in most cases. Why? Initial major steps in endograft evolution Papazoglou O. Konstantinos M.D. The story of a major breakthrough in vascular surgery 1991 Parodi introduces

More information

Abdominal Aortic Aneurysms. A Surgeons Perspective Dr. Derek D. Muehrcke

Abdominal Aortic Aneurysms. A Surgeons Perspective Dr. Derek D. Muehrcke Abdominal Aortic Aneurysms A Surgeons Perspective Dr. Derek D. Muehrcke Aneurysm Definition The abnormal enlargement or bulging of an artery caused by an injury or weakness in the blood vessel wall A localized

More information

Bilateral use of the Gore IBE device for bilateral CIA aneurysms and a first interim analysis of the prospective Iceberg registry

Bilateral use of the Gore IBE device for bilateral CIA aneurysms and a first interim analysis of the prospective Iceberg registry Bilateral use of the Gore IBE device for bilateral CIA aneurysms and a first interim analysis of the prospective Iceberg registry Michel MPJ Reijnen, MD, PhD Department of Vascular Surgery, Rijnstate Hospital

More information

Endovascular aneurysm repair (EVAR) for the

Endovascular aneurysm repair (EVAR) for the The Fenestrated Anaconda for the Treatment of Complex Abdominal Aortic Aneurysms An overview of the design, applicability, and clinical success of the Fenestrated Anaconda System for complex abdominal

More information

Citation for published version (APA): Tielliu, I. F. J. (2010). Endovascular repair of peripheral artery aneurysms Groningen: s.n.

Citation for published version (APA): Tielliu, I. F. J. (2010). Endovascular repair of peripheral artery aneurysms Groningen: s.n. University of Groningen Endovascular repair of peripheral artery aneurysms Tielliu, Ignace François Jacques IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish

More information

Challenges in the treatment of infrarenal aneurysm & considerations for a durable repair

Challenges in the treatment of infrarenal aneurysm & considerations for a durable repair Challenges in the treatment of infrarenal aneurysm & considerations for a durable repair Nilo J Mosquera, MD. Head of Department Angiology and Vascular Surgery. CHUO Hospital. Ourense. Spain Disclosure

More information

Disclosures. EVAR follow-up: actual recommendation. EVAR follow-up: critical issues

Disclosures. EVAR follow-up: actual recommendation. EVAR follow-up: critical issues Disclosures is it time to discuss individualized follow-up schemes based on preoperative anatomy and high quality completion angiography? Consultant / Speaker / Proctor Cook Cordis Medtronic Invatec W.L.

More information

Thoracoabdominal Aorta: Advances and Novel Therapies

Thoracoabdominal Aorta: Advances and Novel Therapies Thoracoabdominal Aorta: Advances and Novel Therapies Robert Meisner, MD FACS Sidney Kimmel Medical Center Assistant Professor of Surgery Vascular / Endovascular Surgeon at Lankenau Medical Center November

More information

NASDAQ: ELGX December Innovation that Empowers

NASDAQ: ELGX  December Innovation that Empowers NASDAQ: ELGX www.endologix.com December 2014 Innovation that Empowers Safe Harbor This presentation contains forward-looking statements within the meaning of the Private Securities Litigation Reform Act

More information

MODERN METHODS FOR TREATING ABDOMINAL ANEURYSMS AND THORACIC AORTIC DISEASE

MODERN METHODS FOR TREATING ABDOMINAL ANEURYSMS AND THORACIC AORTIC DISEASE MODERN METHODS FOR TREATING ABDOMINAL ANEURYSMS AND THORACIC AORTIC DISEASE AAA FACTS 200,000 New Cases Each Year Ruptured AAA = 15,000 Deaths per Year in U.S. 13th Leading Cause of Death 80% Chance of

More information

THE ENDURANT STENT GRAFT IN HOSTILE ANEURYSM NECK ANATOMY

THE ENDURANT STENT GRAFT IN HOSTILE ANEURYSM NECK ANATOMY THE ENDURANT STENT GRAFT IN HOSTILE ANEURYSM NECK ANATOMY Patrice Mwipatayi FCS (SA), MMed, FRACS Professor of Vascular surgery Royal Perth Hospital, University of Western Australia, Perth, WA Co-Authors:

More information

for Thoracoabdominal Aneurysms

for Thoracoabdominal Aneurysms Durability of F/BEVAR for Thoracoabdominal Aneurysms Athanasios Katsargyris, MD, Eric Verhoeven MD, PhD Department of Vascular and Endovascular Surgery Paracelsus Medical University, Nuremberg, Germany

More information

Endovascular Management of Thoracic Aortic Pathology Stéphan Haulon, J Sobocinski, B Maurel, T Martin-Gonzalez, R Spear, A Hertault, R Azzaoui

Endovascular Management of Thoracic Aortic Pathology Stéphan Haulon, J Sobocinski, B Maurel, T Martin-Gonzalez, R Spear, A Hertault, R Azzaoui Endovascular Management of Thoracic Aortic Pathology Stéphan Haulon, J Sobocinski, B Maurel, T Martin-Gonzalez, R Spear, A Hertault, R Azzaoui Aortic Center, Lille University Hospital, France Disclosures

More information

Dr Peter Bungay Derbyshire Vascular Services Royal Derby Hospital Derby UK

Dr Peter Bungay Derbyshire Vascular Services Royal Derby Hospital Derby UK Dr Peter Bungay Derbyshire Vascular Services Royal Derby Hospital Derby UK Disclosure I have the following potential conflicts of interest to report Consultant, proctor and paid speaker for Vascutek UK

More information

The evolution. AORFIX AAA Stent Graft now with the new AORFLEX Delivery System

The evolution. AORFIX AAA Stent Graft now with the new AORFLEX Delivery System The evolution of AORFIX AORFIX AAA Stent Graft now with the new AORFLEX Delivery System The confident choice for the right angles AORFIX the only AAA stent graft approved for all angulations from 0 90,

More information

GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability. Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands

GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability. Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands Disclosure Speaker name: Michel Reijnen I have the following potential conflicts

More information

2014 ANNUAL CLINICAL UPDATE. TriVascular Inc. Ovation and Ovation Prime Abdominal Stent Graft Systems

2014 ANNUAL CLINICAL UPDATE. TriVascular Inc. Ovation and Ovation Prime Abdominal Stent Graft Systems 2014 ANNUAL CLINICAL UPDATE TriVascular Inc. Ovation and Ovation Prime Abdominal Stent Graft Systems 2014 ANNUAL CLINICAL UPDATE TriVascular Inc. Ovation and Ovation Prime Abdominal Stent Graft Systems

More information

Treatment options of late failures of EVAS. Michel Reijnen Rijnstate Arnhem The Netherlands

Treatment options of late failures of EVAS. Michel Reijnen Rijnstate Arnhem The Netherlands Treatment options of late failures of EVAS Michel Reijnen Rijnstate Arnhem The Netherlands Disclosure Speaker name: Michel Reijnen I have the following potential conflicts of interest to report: Consulting

More information

THORACOABDOMINAL AORTIC ANEURYSMS HYBRID REPAIR

THORACOABDOMINAL AORTIC ANEURYSMS HYBRID REPAIR Update on Open and Endovascular Therapeutic Option for Aortic Repair CENTRE CARDIO-TORACIQUE DE MONACO Friday November 7 th, 2014 THORACOABDOMINAL AORTIC ANEURYSMS HYBRID REPAIR Roberto Chiesa Vascular

More information

Quick Reference Guide

Quick Reference Guide Quick Reference Guide Indications for Use The AFX Endovascular AAA System is indicated for endovascular treatment in patients with AAA. The devices are indicated for patients with suitable aneurysm morphology

More information

Aorfix Pythagoras US Clinical Trial:

Aorfix Pythagoras US Clinical Trial: Overall 1 Year Results from the Aorfix Pythagoras US Clinical Trial: 1 st IDE Study in Highly Angulated 60 133 Aortic Necks Mark Fillinger MD for the PYTHAGORAS Investigators Disclosure Speaker name: Mark

More information

FLEXIBLE, BALOON EXPANDABLE

FLEXIBLE, BALOON EXPANDABLE EARLY RESULTS OF A CLINICAL TRIAL OF FLEXIBLE, BALOON EXPANDABLE COVERED STENT GRAFT IN ILIAC OCCLUSIVE DISEASE Chris LeCroy Coastal Vascular and Interventional Pensacola, Florida Clinical Trial WL GORE

More information

Important Update to Field Safety Notice Nellix EndoVascular Aneurysm Sealing System Updated Instructions for Use (IFU)

Important Update to Field Safety Notice Nellix EndoVascular Aneurysm Sealing System Updated Instructions for Use (IFU) October 6, 2017 Important Update to Field Safety Notice Nellix EndoVascular Aneurysm Sealing System Updated Instructions for Use (IFU) Dear Physician, This notification is to provide you with further information

More information

Acute dissections of the descending thoracic aorta (Debakey

Acute dissections of the descending thoracic aorta (Debakey Endovascular Treatment of Acute Descending Thoracic Aortic Dissections Nimesh D. Desai, MD, PhD, and Joseph E. Bavaria, MD Acute dissections of the descending thoracic aorta (Debakey type III or Stanford

More information

Technique and Tips for Complicated AAA Cases with Stent Graft

Technique and Tips for Complicated AAA Cases with Stent Graft Technique and Tips for Complicated AAA Cases with Stent Graft Seung-Woon Rha, MD, PhD FACC, FAHA, FESC, FSCAI, FAPSIC Cardiovascular Center, Korea University Guro Hospital Mar 15, 2018 LINC AP 2018 Endoleak;

More information

Overcoming Challenging Aortic Anatomy: from Hostile Necks to Tortuous Iliac arteries

Overcoming Challenging Aortic Anatomy: from Hostile Necks to Tortuous Iliac arteries Overcoming Challenging Aortic Anatomy: from Hostile Necks to Tortuous Iliac arteries Robert Fisher Royal Liverpool University Hospital, UK Liverpool Vascular and Endovascular Service Introduction Late

More information

COMPLICATIONS OF TEVAR

COMPLICATIONS OF TEVAR COMPLICATIONS OF TEVAR P. Bergeron, A.Petrosyan, F.Markatis, T.Abdulamit, J.-C. Trastour IMAD CONGRESS 2010 Liège Belgium BACKGROUND Stentgrafting is a recognized treatment for TAA & TAD and has been proposed

More information

Anatomical applicability of current off-the-shelf branched endografts in thoracoabdominal aortic aneurysms managed by open surgery.

Anatomical applicability of current off-the-shelf branched endografts in thoracoabdominal aortic aneurysms managed by open surgery. Leipzig Interventional Course Update on clinical trials Tuesday, January 30 th, 2018 Anatomical applicability of current off-the-shelf branched endografts in thoracoabdominal aortic aneurysms managed by

More information

Type 1a Endoleak in hostile neck anatomies: Endoanchor can fix it! D. Böckler University Hospital Heidelberg, Germany

Type 1a Endoleak in hostile neck anatomies: Endoanchor can fix it! D. Böckler University Hospital Heidelberg, Germany Type 1a Endoleak in hostile neck anatomies: Endoanchor can fix it! D. Böckler University Hospital Heidelberg, Germany Disclosures Speaker name: Dittmar Böckler I have the following potential conflicts

More information

Title. Different arch branched devices are available, is morphology the. main criteria of choice? Ciro Ferrer, MD

Title. Different arch branched devices are available, is morphology the. main criteria of choice? Ciro Ferrer, MD Different arch branched devices are available, is morphology the Title main criteria of choice? Ciro Ferrer, MD Vascular Surgery Unit Sapienza University of Rome Disclosure Speaker name: Ciro Ferrer Proctoring/speaking

More information

Development of a Branched LSA Endograft & Ascending Aorta Endograft

Development of a Branched LSA Endograft & Ascending Aorta Endograft Development of a Branched LSA Endograft & Ascending Aorta Endograft Frank R. Arko III, MD Sanger Heart & Vascular Institute Carolinas Medical Center Charlotte, North Carolina, USA Disclosures Proximal

More information

Management of Endoleaks

Management of Endoleaks Management of Endoleaks Murray Shames, MD Professor and Chief, Director Tampa General Hospital Aortic Program Vice Chair of Research, Dept. of Surgery Conflict of Interests: Speaker: Gore, Medtronic, Cook

More information

2015 Clinical Update Endovascular Systems for AAA Repair

2015 Clinical Update Endovascular Systems for AAA Repair Endovascular Systems for AAA Repair 2 Musick Irvine, CA 92618 Tel 949.595.7200 Fax 949.612.1893 www.endologix.com TABLE OF CONTENTS Section Page ABSTRACT... 3 READER S GUIDE... 4 SECTION 1: US PIVOTAL

More information