Brief History of the BAM s for paper thickness s pollution measures spm10fem E-BAM developed PM 2.5 FEM

Size: px
Start display at page:

Download "Brief History of the BAM s for paper thickness s pollution measures spm10fem E-BAM developed PM 2.5 FEM"

Transcription

1 Preliminary PM 2.5 BAM/TEOM/FRM Data Hoke P. Kimball MARAMA Monitoring Meeting Richmond, VA November 17-19, 19, 2008

2 Brief History of the BAM s for paper thickness s pollution measures spm10fem E-BAM developed PM 2.5 FEM

3 Beta Attenuation Carbon 14 beta rays are emitted to a detector. Particles absorb the radiation and the monitor measures the reduction in the Beta count in relation to the Beer-Lambert law.

4 BAM 1020 (Beta Attenuation Monitor) Met One Instruments Grants Pass, Oregon August, 2008

5 FEM Status EPA Granted Federal Equivalent Method (FEM) Status to the BAM 1020 for the Measurement of PM 2.5 on 3/12/08

6 To Maintain FEM Status the BAM 1020 Must: Provide 1-hour Average Concentration Values Provide at Least 18 1-hour Average Values per 24-Hour Period Provide Concentrations Based on Actual Flow (local ambient conditions of Temp./Pressure)

7 To Maintain FEM Status, Cont d Use Firmware Version or Later Use Tape Drive Transport Rev D or later Control Shelter Temperature to within ± 2 Degrees C over any 1-Hour Sampling Period Use a PM 10 Head and a PM 2.5 VSCC

8 To Maintain FEM Status, Cont d Maintain Sample RH < 35% Use a Glass Fiber Filter Tape Sample for 42 Minutes of Each Hour Count Beta Particles For 8 minutes Operate at a Flow Rate of LPM

9 BAM Operational Features Attenuation of Beta Particles Carbon 14 (exempt source) New Filter Spot Every Hour Hourly Zero and Span Checks Filter Tape Good for Two Months Changing g PM Composition Has No Affect On Beta Attenuation Post Filter Analysis Possible Standard Range is ug/m 3

10 Bam Operational Features, Cont d Accuracy (24 hour Average) = ±2 ug Resolution = ± 1 ug/m 3 Maintains Sample Stream RH < 35% Compatible With ESC Data Loggers

11 BX-802 PM 10 Head BX-808 BGI VSCC PM 2.5 Cyclone (optional) BX-596 AT/BP Sensor (or BX-592) Inlet Tube 8119 Seal adds 14.0 adds typical Inlet tube BX-827 or 830 Smart Heater with Mounting insulation Rack BX-902/903 Environment al Enclosure BAM 1020 MET ONE INSTRUMENTS SETUPMODESENSOR CHID TYPE UNITS PREC MULT OFFSET 0100 no V SENSORFSVOLT:1.0 INVSLOPE:NVECT/SCALAR:SMODE:AUTO VECT/SCALAR:SMODE:AUTO ID SAVE IDMODE EXIT -Total Height- 6.6 ft (2.0 meters) without cyclone 7.0 ft (2.1 meters) with cyclone BX-126 Vacuum Pump or equivalent

12 BAM Components

13 Method Comparison (Flow Rate Through Filter) FRM BAM TEOM LPM 16.7 LPM 3.0 LPM

14 Method Comparison, Cont d (PM Collection Time Period) FRM TEOM BAM 24 hours Continuous 1 hr. Readings Continuous 1 Hour

15 Method Comparison, Cont d (Filter Material) FRM TEOM BAM Teflon Teflon Coated Glass Fiber Glass Fiber

16 Method Comparison, Cont d (Filter Conditions) FRM TEOM BAM Subject to Ambient Conditions of Ambient Temp. and RH Operates at 50 Degrees C RH Controlled to 35% or Less

17 Method Comparison, Cont d (Data Availability) FRM TEOM BAM 4-5 Days After Sampling Hourly Hourly

18 TEOM vs BAM vs FRM (February) Millbrook February 25 ug/ /m /4 2/6 2/8 2/10 2/12 2/14 2/16 Date 2/18 2/20 2/22 2/24 2/26 2/28 TEOM BAM FRM

19 TEOM vs BAM vs FRM (March) Millbrook March ug g/m TEOM BAM FRM 3/1 3/4 3/7 3/10 3/13 3/16 3/19 3/22 3/25 3/28 3/31 Date

20 TEOM vs BAM vs FRM (April) Millbrook April ug g/m TEOM BAM FRM 4/1 4/4 4/7 4/10 4/13 4/16 4/19 4/22 4/25 4/28 Date

21 TEOM vs BAM vs FRM (May) Millbrook May ug g/m TEOM BAM FRM 5/1 5/4 5/7 5/10 5/13 5/16 5/19 5/22 5/25 5/28 5/31 Date

22 TEOM vs BAM vs FRM (June) Millbrook June TEOM BAM FRM ug /m 3 6/1 6/3 6/5 6/7 6/9 6/11 6/13 6/15 6/17 6/19 6/21 6/23 6/25 6/27 6/29 Date

23 Data Comparison (Avg. Monthly Concentration, ug/m 3 ) Feb March April May June * June ** FRM TEOM BAM * Includes 6/12/08 Exceptional Event ** Excludes 6/12/08 Exceptional Event

24 Data Comparison, Cont d (Avg. Monthly Conc. Difference vs FRM, ug/m 3 ) Feb March April May June * June ** TEOM BAM * Includes 6/12/08 Exceptional Event ** Excludes 6/12/08 Exceptional Event

25 Data Comparison, Cont d (BAM vs TEOM) Feb March April May June * June ** Avg. ug/m 3 Diff Avg. % Diff * Includes 6/12/08 Exceptional Event ** Excludes 6/12/08 Exceptional Event

26 Data Comparison, Cont d (Exceptional Event of June 12, 2008, FRM vs TEOM vs BAM) FRM TEOM BAM * 24-Hr. Avg., ug/m * BAM Measures Volatile Components Lost by FRM and TEOM

27

28

29

30 Conclusions (Based on Limited Data) BAM & TEOM* >FRMbyupto20-25% 25% BAM > TEOM by up to 5-6% Including 6/12/08 Exceptional Event Data -BAM & FRM are Significantly Different - BAM & TEOM are not Significantly Different - FRM & TEOM are not Significantly Different Loss of Volatile PM Reason for Difference Need d1y Year of fd Data From the 3P Proposed dsit Sites * TEOM is normally corrected to be FRM-like

31 Questions?

What is the Difference Between the New BAM-1020 PM2.5 FEM and Older BAM-1020 Monitors?

What is the Difference Between the New BAM-1020 PM2.5 FEM and Older BAM-1020 Monitors? Met One Technical Bulletin Revised: April 21, 2009 By: Dennis Hart Met One Instruments, Inc. 1600 N.W. Washington Blvd. Grants Pass, OR 97526 (541) 471-7111 www.metone.com What is the Difference Between

More information

BAM Monitor Performance. Seasonal and Geographic Variation in NC

BAM Monitor Performance. Seasonal and Geographic Variation in NC BAM Monitor Performance Seasonal and Geographic Variation in NC 2009-10 2 Presenter Wayne Cornelius 3 Introduction Unsuccessful ARM tests in 2007 and 2009, using a configuration of R&P TEOM monitor. Acquired

More information

Laboratory Evaluation Aeroqual S-500 OZU Ozone Sensor

Laboratory Evaluation Aeroqual S-500 OZU Ozone Sensor Laboratory Evaluation Aeroqual S-5 OZU Ozone Sensor Background Three Aeroqual Series S-5 (model OZU, -.15ppm) portable ozone monitors that were previously field-tested at the SCAQMD Rubidoux fixed ambient

More information

EMERGING TECHNOLOGIES: MONITORING FOR TOMORROW

EMERGING TECHNOLOGIES: MONITORING FOR TOMORROW EMERGING TECHNOLOGIES: MONITORING FOR TOMORROW 1 2 Background & Purposes Introduction Tech #1 BAM 1022 Purpose: Standalone cont. PM2.5 BAM unit Tech #2 Carbon-SASS Purpose: Combining SASS and URG units

More information

Beach Name City No. of Fire Rings LOS ANGELES COUNTY Total = 79. ORANGE COUNTY Total = 687

Beach Name City No. of Fire Rings LOS ANGELES COUNTY Total = 79. ORANGE COUNTY Total = 687 Newport Beach June 13th El Segundo June 14th Background Newport Beach request to the Coastal Commission to remove fire rings Commission staff cited exemption in SCAQMD rules as justification to deny request

More information

STANDARD OPERATING PROCEDURE: RIGAKU RU 300 XRD POWDER SAMPLES

STANDARD OPERATING PROCEDURE: RIGAKU RU 300 XRD POWDER SAMPLES STANDARD OPERATING PROCEDURE: RIGAKU RU 300 XRD POWDER SAMPLES Purpose of this instrument: The Rigaku RU 300 XRD is used for phase analysis of polycrystalline films, characterizing single crystal, and

More information

IRRADIATORS. September 11, :00 am-5:00 pm Hock Plaza Auditorium Duke University Medical Center, Erwin Road

IRRADIATORS. September 11, :00 am-5:00 pm Hock Plaza Auditorium Duke University Medical Center, Erwin Road IRRADIATORS Terry Yoshizumi,, PhD September 11, 2006 8:00 am-5:00 pm Hock Plaza Auditorium Duke University Medical Center, Erwin Road Radiation Countermeasures Center of Research Excellence 1 Acknowledgements

More information

GRIMM. European Approval PM10 & PM2.5. situation & legislation for. Aerosol Technik

GRIMM. European Approval PM10 & PM2.5. situation & legislation for. Aerosol Technik GRIMM Aerosol Technik European Approval situation & legislation for PM10 & PM2.5 AGENDA Legislation Guidance of euqivalence EDM180 - PM10 EDM180 - PM2.5 Certifications PM2.5 start with 1.1.2009 For PM10

More information

Appendix A. Ambient PM2.5 Data Analysis

Appendix A. Ambient PM2.5 Data Analysis Appendix A Ambient PM2.5 Data Analysis DRAFT 218 Plan for the 1997, 26, and 212 PM2.5 Standards August 31, 218 This page intentionally blank. Appendix A: Ambient PM2.5 Data Analysis DRAFT 218 Plan for

More information

Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2

Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2 Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2 Ordering Information You may contact us via phone, fax, e-mail, or through our website. EPOND S.A. CP 389 CH-1800 Vevey Switzerland Phone:

More information

Brian P. Frank 1, Jacqueline Perry 1, H.D. Felton 1, Robert C. Anderson 2, Oliver Rattigan 1, Kevin Civerolo 1, and Olga Hogrefe 3

Brian P. Frank 1, Jacqueline Perry 1, H.D. Felton 1, Robert C. Anderson 2, Oliver Rattigan 1, Kevin Civerolo 1, and Olga Hogrefe 3 Intercomparison of Long-Term Ambient Ultrafine Particle Size Distribution Measurements at a Near-Roadway and a Representative Urban Site in New York City Brian P. Frank 1, Jacqueline Perry 1, H.D. Felton

More information

Dental Intraoral X-ray Systems

Dental Intraoral X-ray Systems Dental Intraoral X-ray Systems PROPOSED REVISIONS TO 4732.XXXX, 2.0 4732.#### DENTAL INTRAORAL X-RAY SYSTEMS; STATIONARY AND MOBILE. Commented [JC(1]: Based on part 4732.0880. Subpart 1. Applicability.

More information

Alignment and Calibration of the APEX Instrument. March 30, Chemical Crystallography Laboratory

Alignment and Calibration of the APEX Instrument. March 30, Chemical Crystallography Laboratory Alignment and Calibration of the APEX Instrument Page 1 of 8 Alignment and Calibration of the APEX Instrument March 30, 2017 Chemical Crystallography Laboratory Author: Douglas R. Powell Alignment and

More information

Hydrolysis Unit B-411 / E-416 Technical data sheet

Hydrolysis Unit B-411 / E-416 Technical data sheet Hydrolysis Unit B-4 / E-46 Technical data sheet The Hydrolysis Unit B-4 and E-46 ensure safe and fast acid hydrolysis for total fat content determination handling four or six samples simultaneously. The

More information

Ordering Information You may contact us via phone, fax, , or through our website.

Ordering Information You may contact us via phone, fax,  , or through our website. Elemental Scientific (ESI) designs and produces a range of sample introduction systems for the determination of trace element concentrations and isotope ratios in liquid samples when using inductively

More information

APPENDIX A Ambient PM2.5 Data Analysis

APPENDIX A Ambient PM2.5 Data Analysis APPENDIX A Ambient PM2.5 Data Analysis DRAFT 218 Plan for the 1997, 26, and 212 PM2.5 Standards Appendix A: Ambient PM2.5 Data Analysis This page intentionally blank. Appendix A: Ambient PM2.5 Data Analysis

More information

Ordering Information You may contact us via phone, fax, , or through our website.

Ordering Information You may contact us via phone, fax,  , or through our website. (ESI) designs and produces a range of sample introduction systems for the determination of trace element concentrations and isotope ratios in liquid samples when using inductively coupled plasma instrumentation

More information

There are many varieties of particulate pollutants in our homes and offices. Ones from outside include industrial

There are many varieties of particulate pollutants in our homes and offices. Ones from outside include industrial Model: IAQ Indoor PM2.5 -PM2.5 Particulate matter (PM) is a particle pollution, which is produced in a great number of ways that can be classified into either mechanical or chemical processes. Traditionally,

More information

Ordering Information You may contact us via phone, fax, , or through our website.

Ordering Information You may contact us via phone, fax,  , or through our website. Elemental Scientific (ESI) designs and produces a range of sample introduction systems for the determination of trace element concentrations and isotope ratios in liquid samples when using inductively

More information

Radiation Safety Refresher Training for 2017 PREPARED BY SUE DUPRÉ RADIATION SAFETY OFFICER

Radiation Safety Refresher Training for 2017 PREPARED BY SUE DUPRÉ RADIATION SAFETY OFFICER Radiation Safety Refresher Training for 2017 PREPARED BY SUE DUPRÉ RADIATION SAFETY OFFICER Topics Radiation safety training for new lab members Preoperational checks for survey meters Radioactive package

More information

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL 1 2 Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...

More information

Validation of Isovaleraldehyde Using SKC UMEx 100 Diffusive Samplers (Cat. No )

Validation of Isovaleraldehyde Using SKC UMEx 100 Diffusive Samplers (Cat. No ) Validation of Isovaleraldehyde Using SKC UMEx 100 Diffusive Samplers (Cat. No. 500-100) Page 1 of 9 Publication 1874 Rev 1607 Research Report Validation of Isovaleraldehyde Using SKC UMEx 100 Diffusive

More information

Dental Clinics Employment of Amalgam Separators, Best Management Practices

Dental Clinics Employment of Amalgam Separators, Best Management Practices Goethe Institut Friday 25 May 2007, 9:50 AM. Dental Clinics Employment of Amalgam Separators, Best Management Practices Public Dental Health Service, County of Uppsala Dental Sector as a Source of Mercury

More information

45 Hr PET Registry Review Course

45 Hr PET Registry Review Course 45 HR PET/CT REGISTRY REVIEW COURSE Course Control Document Timothy K. Marshel, MBA, R.T. (R), (N)(CT)(MR)(NCT)(PET)(CNMT) The PET/CT Training Institute, Inc. SNMMI-TS 028600-028632 45hr CEH s Voice Credits

More information

Radon Gas & What You Need to Know. Bob Caskanette, B.A.Sc., CEC, CAQS, CRS, CIEC, C.E.T., EP (C-NRPP Certified) Caskanette Udall Consulting Engineers

Radon Gas & What You Need to Know. Bob Caskanette, B.A.Sc., CEC, CAQS, CRS, CIEC, C.E.T., EP (C-NRPP Certified) Caskanette Udall Consulting Engineers Radon Gas & What You Need to Know Bob Caskanette, B.A.Sc., CEC, CAQS, CRS, CIEC, C.E.T., EP (C-NRPP Certified) Caskanette Udall Consulting Engineers What is Radon? Naturally occurring radioactive soil

More information

EUEC 2015 Experience using Cavity Enhanced Absorption Spectroscopy (CEAS) for HCl measurement on a coal-fired power plant

EUEC 2015 Experience using Cavity Enhanced Absorption Spectroscopy (CEAS) for HCl measurement on a coal-fired power plant Steve Gibbons, Business Development - CEMS EUEC 2015 Experience using Cavity Enhanced Absorption Spectroscopy (CEAS) for HCl measurement on a coal-fired power plant Introduction Steve Gibbons Business

More information

Savillex Technical Note C-Flow 700d PFA Concentric Nebulizer for ICP-OES

Savillex Technical Note C-Flow 700d PFA Concentric Nebulizer for ICP-OES Savillex Technical Note C-Flow 700d PFA Concentric Nebulizer for ICP-OES Summary The Savillex C-Flow 700d (C700d) is a concentric PFA nebulizer designed specifically for ICP-OES, combining extreme matrix

More information

Comparison of a UPLC Method across Multiple UHPLC Systems

Comparison of a UPLC Method across Multiple UHPLC Systems Comparison of a UPLC Method across Multiple UHPLC Systems Tanya Jenkins Waters Corporation, Milford, MA, U.S. INTRODUCTION In 2004, Waters introduced the ACQUITY UPLC System. Since this launch, many liquid

More information

Basic understanding of smoke impacts. Overview-NM Smoke Management Program. Show tools we use to inform YOU about smoke

Basic understanding of smoke impacts. Overview-NM Smoke Management Program. Show tools we use to inform YOU about smoke Basic understanding of smoke impacts Overview-NM Smoke Management Program Show tools we use to inform YOU about smoke PARTICULATE MONITORING REGIONAL HAZE FIRE BEHAVIOR FUEL CONSUMPTION PM 10 VENTILATION

More information

Radon in Chelsea. September 2014 Louis-Marie Poissant, M. Sc. Env.

Radon in Chelsea. September 2014 Louis-Marie Poissant, M. Sc. Env. Radon in Chelsea September 2014 Louis-Marie Poissant, M. Sc. Env. Outline 1. Understanding radon 2. Health risks related to radon 3. Cancer and probability 4. Importance of taking long term measurements

More information

Risk and Risk Reduction. Environmental Health and Safety. Radiation Safety. Radiation is all around us

Risk and Risk Reduction. Environmental Health and Safety. Radiation Safety. Radiation is all around us Risk and Risk Reduction Radiation is all around us Environmental Health and Safety Radiation Safety Risk and Risk Reduction Risk Webster s dictionary defines risk as the chance of injury, damage, or loss;

More information

Section 3 Evaluation of the Effectiveness of Air-Purifying Respirator Cartridges in Removing MDI Aerosols from Air

Section 3 Evaluation of the Effectiveness of Air-Purifying Respirator Cartridges in Removing MDI Aerosols from Air Section 3 Evaluation of the Effectiveness of Air-Purifying Respirator Cartridges in Removing MDI Aerosols from Air SUMMARY Authors M. W. Spence* T. D. Landry* D. W. Huff* *Environment, Health, and Safety

More information

David M. Shelow, Restek Corporation, 110 Benner Circle, Bellefonte, PA 16823

David M. Shelow, Restek Corporation, 110 Benner Circle, Bellefonte, PA 16823 USE OF SILCOCAN CANISTERS FOR STORING LOW-LEVEL (1ppb-ppb) REACTIVE SULFURS IN AIR David M. Shelow, Restek Corporation, 11 Benner Circle, Bellefonte, PA 16823 INTRODUCTION Analysis of sulfur-containing

More information

THE RIGAKU JOURNAL VOL. 23 / 2006, A1-A10 CONSIDERATIONS REGARDING THE ALIGNMENT OF DIFFRACTOMETERS FOR RESIDUAL STRESS ANALYSIS

THE RIGAKU JOURNAL VOL. 23 / 2006, A1-A10 CONSIDERATIONS REGARDING THE ALIGNMENT OF DIFFRACTOMETERS FOR RESIDUAL STRESS ANALYSIS THE RIGAKU JOURNAL VOL. 23 / 2006, A1-A10 CONSIDERATIONS REGARDING THE ALIGNMENT OF DIFFRACTOMETERS FOR RESIDUAL STRESS ANALYSIS THOMAS R. WATKINS, O. BURL CAVIN, CAMDEN R. HUBBARD, BETH MATLOCK, AND ROGER

More information

Instruction for the Laboratory of Biophysics. Colorimetric assay. Laboratory 4

Instruction for the Laboratory of Biophysics. Colorimetric assay. Laboratory 4 Laboratory 4 Colorimetric assay Instruction for the Laboratory of Biophysics I. THEORETICAL INTRODUCTION The term absorption refers to the physical process of absorbing light, which is the basic principal

More information

ELEMENT 2/ ELEMENT XR Consumables and Parts Catalog

ELEMENT 2/ ELEMENT XR Consumables and Parts Catalog ELEMENT 2/ ELEMENT XR Consumables and Parts Catalog Revision B - 2 470 Analyze Detect Measure Control 2007 Thermo Fisher Scientific. All rights reserved. Viton is a registered trademark of DuPont Dow Elastomers.

More information

Nitrogen and Protein Determination in Meat Products by Accelerated Digestion with Hydrogen Peroxide and Sulfuric Acid

Nitrogen and Protein Determination in Meat Products by Accelerated Digestion with Hydrogen Peroxide and Sulfuric Acid 071/2011 SpeedDigester K-436, K-439 Kjeldahl Sampler System K-370/K-371 Nitrogen and Protein Determination in Meat Products by Accelerated Digestion with Hydrogen Peroxide and Sulfuric Acid 071/2011 SpeedDigester

More information

Dollars and Sense: Are We Overshielding Imaging Facilities? Part 2

Dollars and Sense: Are We Overshielding Imaging Facilities? Part 2 Disclosure Dollars and Sense: Are We Overshielding Imaging Facilities? Part 2 Bryon M. Murray, M.S., DABR Paid consultant to NELCO Worldwide Owner, CEO ZapIT! Medical Objectives Understand methods for

More information

Investigating the Oxidative Rancidity of Polyunsaturated Oils

Investigating the Oxidative Rancidity of Polyunsaturated Oils 1 Investigating the Oxidative Rancidity of Polyunsaturated Oils Research Question How do different storage temperatures (-20.0, 4.0, 25.0, 40.0, 60.0 ºC) of sunflower oil affect the relative concentration

More information

Radiation Detection and Measurement

Radiation Detection and Measurement Radiation Detection and Measurement Range of charged particles (e.g.,!: µm; ": mm) Range of high energy photons (cm) Two main types of interactions of high energy photons Compton scatter Photoelectric

More information

Topic 6 Benefits and drawbacks of using radioactive materials

Topic 6 Benefits and drawbacks of using radioactive materials Topic 6 Benefits and drawbacks of using radioactive materials CHANGING IDEAS When radioactivity was first discovered in the late 1800s, scientists did not know it was dangerous: o Becquerel handled radioactive

More information

Disclosures. Outline. Learning Objectives. Introduction. Introduction. Stereotactic Breast Biopsy vs Mammography: Image Quality and Dose.

Disclosures. Outline. Learning Objectives. Introduction. Introduction. Stereotactic Breast Biopsy vs Mammography: Image Quality and Dose. Disclosures Stereotactic Biopsy vs Mammography: and Dose None Vikas Patel, PhD, DABR Upstate Medical Physics 2014 Annual Meeting The American Association of Physicists in Medicine Austin, TX Learning Objectives

More information

Savillex Technical Note

Savillex Technical Note Savillex Technical Note C700d PFA Concentric Nebulizer for ICP-OES Summary The Savillex C-Flow 700d (C700d) is a concentric PFA nebulizer designed specifically for ICP-OES, combining extreme matrix tolerance

More information

Amalgam Containment and Recycling: Attaining Zero Mercury Discharge in Dental Office Wastewater

Amalgam Containment and Recycling: Attaining Zero Mercury Discharge in Dental Office Wastewater Amalgam Containment and Recycling: Attaining Zero Mercury Discharge in Dental Office Wastewater Legislation: Regulations Effective December 31, 2013 Amalgam Separator; installation and operation; Requirements.

More information

RADIATION MONITORING DEVICES R A D I A T I O N P R O T E C T I O N & B I O L O G Y - R H O D E S

RADIATION MONITORING DEVICES R A D I A T I O N P R O T E C T I O N & B I O L O G Y - R H O D E S RADIATION MONITORING DEVICES 10-526- 1 9 7 R A D I A T I O N P R O T E C T I O N & B I O L O G Y - R H O D E S DETECTION AND MEASUREMENT OF IONIZING RADIATION Dosimeter Dose-measuring device Two classifications:

More information

Particulate Matter and NSR Permitting in Maryland and Delaware

Particulate Matter and NSR Permitting in Maryland and Delaware Particulate Matter and NSR Permitting in Maryland and Delaware Gerallyn Duke EPA Region 3 March 28, 2012 4/2/2012 1 Today s Discussion What is PM/PM10/PM2.5? How is it measured? What does the PM2.5 NSR

More information

Computational Fluid Dynamics Modeling of Amsino OneMask Oxygen Mask

Computational Fluid Dynamics Modeling of Amsino OneMask Oxygen Mask Computational Fluid Dynamics Modeling of Amsino OneMask Oxygen Mask Abstract This study s objective was to model the Amsino OneMask Oxygen Mask using Computational Fluid Dynamics (CFD). A three-dimensional

More information

Restek PAL SPME Fibers cat.#

Restek PAL SPME Fibers cat.# 1 Restek PAL SPME Fibers cat.# 27478 27483 Solid phase microextraction (SPME) fibers are used to extract organic compounds from solid, liquid, and vapor matrices onto a stationary phase that is bonded

More information

MEDICAL EQUIPMENT II HEMODIALYSIS

MEDICAL EQUIPMENT II HEMODIALYSIS MEDICAL EQUIPMENT II - 2012 HEMODIALYSIS Lecture 1 Prof. Yasser Mostafa Kadah Hemodialysis Machines Single-patient hemodialysis machines deliver a patient s dialysis prescription by controlling blood and

More information

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. L19: Optimization of Protection in Mammography

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. L19: Optimization of Protection in Mammography IAEA Training Material on Radiation Protection in Diagnostic and Interventional Radiology RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY L19: Optimization of Protection in Mammography

More information

Calibration Factors and Time-and-Distance Guidelines For Use of Theatrical Fog Equipment

Calibration Factors and Time-and-Distance Guidelines For Use of Theatrical Fog Equipment Calibration Factors and Time-and-Distance Guidelines NewRuleFX Electronic Actor Cigarette Prop with Cartridge Fluid Prepared for: New Rule Productions, Inc. Van Nuys, California and Foresight Theatrical

More information

SHORT TERM HEALTH IMPACTS OF HIGH PM EPISODES ON THE BISHOP PAIUTE RESERVATION

SHORT TERM HEALTH IMPACTS OF HIGH PM EPISODES ON THE BISHOP PAIUTE RESERVATION BISHOP PAIUTE TRIBE ENVIRONMENTAL MANAGEMENT OFFICE AIR PROGRAM SHORT TERM HEALTH IMPACTS OF HIGH PM EPISODES ON THE BISHOP PAIUTE RESERVATION Prepared for The Bishop Tribal Council 50 Tu Su Lane Bishop,

More information

CANADA SENSORS TECHNOLOGY INC.

CANADA SENSORS TECHNOLOGY INC. CANADA SENSORS TECHNOLOGY INC. Manufacturer of Advanced Technology Pressure & Level Transmitters PRESSURE TRANSMITTER PROCESS 1 HART Enabled Intrinsically Safe Model Canada Sensors intelligent transmitters

More information

ESS Method 310.2: Phosphorus, Total, Low Level (Persulfate Digestion)

ESS Method 310.2: Phosphorus, Total, Low Level (Persulfate Digestion) ESS Method 310.2: Phosphorus, Total, Low Level (Persulfate Digestion) Environmental Sciences Section Inorganic Chemistry Unit Wisconsin State Lab of Hygiene 465 Henry Mall Madison, WI 53706 Revised October

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the

More information

PtPt-electrode with temperature sensor, Intellical MTC695

PtPt-electrode with temperature sensor, Intellical MTC695 Total Chlorine DOC316.52.93092 Based on 4500-Cl D in Standard Methods for the Examination of Water and Wastewater Amperometric Forward Titration 0.003 5.00 mg/l as Cl 2 1. Introduction This application

More information

M. A. CECIL & ASSOCIATES, INC Shannon Way, Port Republic, Maryland (301) INDUSTRIAL HYGIENE AND ENVIRONMENTAL HEALTH

M. A. CECIL & ASSOCIATES, INC Shannon Way, Port Republic, Maryland (301) INDUSTRIAL HYGIENE AND ENVIRONMENTAL HEALTH M. A. CECIL & ASSOCIATES, INC. 4475 Shannon Way, Port Republic, Maryland 20676 (301) 855-7710 INDUSTRIAL HYGIENE AND ENVIRONMENTAL HEALTH October 17, 2013 Mr. Sean Yarup Montgomery County Public Schools

More information

Membrane Systems for Recovery of CFC-12 and Other Aerosol Propellants

Membrane Systems for Recovery of CFC-12 and Other Aerosol Propellants Membrane Systems for Recovery of CFC-12 and Other Aerosol Propellants Marc Jacobs, David Dortmundt, Jiirgen Kaschemekat and Anna Russell Membrane Technology and Research, nc. 1360 Willow Road, Menlo Park,

More information

DLR / FOCA Line Loss Study 2009 /2010

DLR / FOCA Line Loss Study 2009 /2010 DLR / FOCA Line Loss Study 2009 /2010 SAE E-31 Cardiff Nov 2010 C. Wahl*, M. Kapernaum*, T. Zornek*, Th. Rindlisbacher #, * # Bundesamt für Zivilluftfahrt BAZL Abteilung Luftfahrtentwickung Folie 1 26.10.2010

More information

"Optimal Dose Techniques and Image Quality: Can We Have Both?" Lorusso, J. R., Fitzgeorge, L., Lorusso, D., & Lorusso, E. 2014

Optimal Dose Techniques and Image Quality: Can We Have Both? Lorusso, J. R., Fitzgeorge, L., Lorusso, D., & Lorusso, E. 2014 "Optimal Dose Techniques and Image Quality: Can We Have Both?" Lorusso, J. R., Fitzgeorge, L., Lorusso, D., & Lorusso, E. 2014 Introduction Background Important to regularly investigate dose optimization

More information

Nuclear Radiation Today

Nuclear Radiation Today CHAPTER 10 13 SECTION Nuclear Changes Nuclear Radiation Today KEY IDEAS As you read this section, keep these questions in mind: Where are some common sources of radiation? What are some beneficial uses

More information

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...

More information

Radiation Safety Characteristics of the NOMAD Portable X-ray System

Radiation Safety Characteristics of the NOMAD Portable X-ray System Radiation Safety Characteristics of the NOMAD Portable X-ray System D. Clark Turner 1, Donald K. Kloos 1, Robert Morton 2 1 ARIBA X-Ray, Inc., 754 South 400 East, Orem, UT 84097 USA, www.aribaxray.com

More information

Paradigm/Guardian CGM Screens. CareLink Online Reports. Make Your Own Jackson Pollack. CGM by Jackson Pollack. How To Read CGM Screens/Reports

Paradigm/Guardian CGM Screens. CareLink Online Reports. Make Your Own Jackson Pollack. CGM by Jackson Pollack. How To Read CGM Screens/Reports CGM by Jackson Pollack One Pollack sold for $140 million in 1996! Make Your Own Jackson Pollack How To Read CGM Screens/Reports For only $1,000! Paradigm/Guardian CGM Screens On-Screen Reports 3 / 6 /

More information

PEEK SS Columns & Guard Columns

PEEK SS Columns & Guard Columns PEEK SS Columns & Guard Columns ~ Stainless Steel Analytical Columns ~ PEEK Columns ID 2.1, 4.0, 4.6 & 7.5 mm ~ Jour-Guard Cartridges Stainless Steel or PEEK ~ Stainless Steel End Fittings 1/4 OD Columns

More information

YY Translated English of Chinese Standard: YY PHARMACEUTICAL INDUSTRY STANDARD

YY Translated English of Chinese Standard: YY PHARMACEUTICAL INDUSTRY STANDARD Translated English of Chinese Standard: YY0766-2009 www.chinesestandard.net Sales@ChineseStandard.net PHARMACEUTICAL INDUSTRY STANDARD YY OF THE PEOPLE S REPUBLIC OF CHINA ICS 11.040.70 C 41 YY 0766-2009

More information

EVALUATION OF CONTINUOUS AND FILTER-BASED METHODS FOR MEASURING PM2.5 MASS CONCENTRATION IN BANDUNG URBAN AREA

EVALUATION OF CONTINUOUS AND FILTER-BASED METHODS FOR MEASURING PM2.5 MASS CONCENTRATION IN BANDUNG URBAN AREA EVALUATION OF CONTINUOUS AND FILTER-BASED METHODS FOR MEASURING PM2.5 MASS CONCENTRATION IN BANDUNG URBAN AREA Fatimah Dinan Qonitan 1*, Puji Lestari 2, and Haryo S. Tomo 3 Master Program of Environmental

More information

Dental Extraoral X-ray Systems

Dental Extraoral X-ray Systems Dental Extraoral X-ray Systems PROPOSED REVISIONS TO 4732.XXXX, 1.0 4732.#### DENTAL EXTRAORAL X-RAY SYSTEMS; STATIONARY AND MOBILE. Subpart 1. Applicability. A registrant s x-ray system used for dental

More information

General Single Ion Calibration. Pete 14-May-09

General Single Ion Calibration. Pete 14-May-09 General Single Ion Calibration Pete 14-May-09 Purpose of SI calibration Measure the instrument response of a single ion. Necessary for understanding of error in instrument (counting statistics) Calculation

More information

Investigation of the Photocatalytic Degradation of Ethanol and Acetone

Investigation of the Photocatalytic Degradation of Ethanol and Acetone ESL-IC--- ICEBO, Shenzhen, China Maximize Comfort: Temperature, Humidity, and IAQ Vol. I-- Investigation of the Photocatalytic Degradation of Ethanol and Acetone Yanhua Liu Bo Ding Shuping Dong Professor

More information

Basic Press Information

Basic Press Information Basic Press Information Contact MedAustron EBG MedAustron GmbH Marie Curie-Strasse 5 A-2700 Wiener Neustadt Austria T +43 2622 26 100-0 e-mail: office@medaustron.at Internet: www.medaustron.at Press contact:

More information

Mammograms Obtained with Rhodium vs Molybdenum Anodes: Contrast and Dose Differences

Mammograms Obtained with Rhodium vs Molybdenum Anodes: Contrast and Dose Differences 1313 C. Kimme-Smith1 J. Wang2 N. DeBruhl1 M. Basic2 L. W. Bassett1 Received October 27, 1 993; accepted after revision January 25, 1994. Presented at the annual meeting of the American Roentgen Ray Society,

More information

Membrane Chip Interface and Accessories

Membrane Chip Interface and Accessories Unit 1, Anglian Business Park, Orchard Road, Royston, Hertfordshire, SG8 5TW, UK T: +44 (0)1763 242491 F: +44 (0)1763 246125 E: sales@dolomite-microfluidics.com W: www.dolomite-microfluidics.com Dolomite

More information

Choose smart valves for balancing Flow

Choose smart valves for balancing Flow Choose smart valves for balancing Flow For easy balancing of the flow NC Flow balancing valves NC Flow is designed for balancing heating and cooling systems. Incorrectly balanced flow is a common cause

More information

Controlling Natural Occurring Radioactive Material (NORM) Exposure

Controlling Natural Occurring Radioactive Material (NORM) Exposure Controlling Natural Occurring Radioactive Material (NORM) Exposure Agenda What is NORM? What is Radiation? Radiation Types Health Effects NORM Oil & Gas Where is NORM Located? How Could I Be Exposed? NORM

More information

The next generation.

The next generation. The next generation. Get active If you re looking for a great kick-start to an active, healthier life, then the Polar Loop is for you. 2 Touch button Suitable for swimming Polar Loop Free guidance with

More information

Skin Model and its impact on Digital Mammography

Skin Model and its impact on Digital Mammography Skin Model and its impact on Digital Mammography Rodrigo T. Massera; Alessandra Tomal Institute of Physics "Gleb Wataghin University of Campinas Campinas, Brazil 1 Outline Motivation Methodology Results

More information

8.05 days 138 days 7.60 days 0.22 mr/h at 1.0 meter per millicurie 124,068 curies/gram 2 mm = 0.20 cm = 0.08 in 165 cm = 65.0 in = 5.

8.05 days 138 days 7.60 days 0.22 mr/h at 1.0 meter per millicurie 124,068 curies/gram 2 mm = 0.20 cm = 0.08 in 165 cm = 65.0 in = 5. Iodine-131 Radiological Safety Guidance Physical Data GAMMA ENERGIES 364 kev (82% abundance) 637 kev (7% abundance) 284 kev (6% abundance) 80 kev (3% abundance) 723 kev (2% abundance) 29-34 kev (4.5%/x-rays)

More information

AIR COOLED CONDENSERS

AIR COOLED CONDENSERS AIR COOLED CONDENSERS SELECTION GUIDE Data Aire, Inc. 230 W. BlueRidge Ave. Orange, CA 92865 www.dataaire.com TABLE OF CONTENTS DARC - Standard outdoor condenser general description... 3 DARC LD - Low

More information

GE Healthcare Life Sciences. Quality matters. Whatman TM filters for air monitoring

GE Healthcare Life Sciences. Quality matters. Whatman TM filters for air monitoring GE Healthcare Life Sciences Quality matters Whatman TM filters for air monitoring Quality matters Why does quality matter? Particulate testing Examples include PM 10 & PM 2.5 particulate monitoring. Quality

More information

Kadi Sarva Vishvavidyalaya, Gandhinagar Bachelor of Engineering (Electrical Engineering Syllabus)

Kadi Sarva Vishvavidyalaya, Gandhinagar Bachelor of Engineering (Electrical Engineering Syllabus) B.E Semester: VI th (EE) Subject Name & Subject code: Industrial Instrumentation (EE-605) Course Objective: To focus on the application of industrial instrumentation of various electrical parameters. To

More information

Short guidelines for the use of the MEMORI dosimeter

Short guidelines for the use of the MEMORI dosimeter Short guidelines for the use of the MEMORI dosimeter Introduction This guide provides advice about how the MEMORI dosimeter should be used to obtain the best information about air quality for the safeguarding

More information

Applications of radioactivity in medicine

Applications of radioactivity in medicine Lec.3 Applications of radioactivity in medicine -Nuclear medicine (N.M) -Applications of radioactive material in medicine Nuclear Medicine:- The clinical uses of radioactivity for the diagnosis of disease.

More information

Determination of Copper in Green Olives using ICP-OES

Determination of Copper in Green Olives using ICP-OES Application Note Food and Agriculture Determination of Copper in Green Olives using ICP-OES Intelligent Rinse function reduced analysis time by 60%, saving 191.4 L of argon Authors Ryley Burgess, Agilent

More information

Agenda: Dental Cone Beam Imaging

Agenda: Dental Cone Beam Imaging Cone Beam Imaging Agenda: Dental Cone Beam Imaging *Definition and Functionality *Usage and diagnostics benefits *Comparative radiation information *Federal regulatory responsibilities: manufacturing *State

More information

BOHS / OHlearning Course Specification

BOHS / OHlearning Course Specification BOHS / OHlearning Course Specification Course Title Noise Measurement and Its Effects Code W503 Level Foundation Intermediate Advanced Other Pre-requisites None Coordinating Editor Bruce Gantner Approval

More information

POTENTIAL HEALTH RISKS

POTENTIAL HEALTH RISKS POTENTIAL HEALTH RISKS July 24, 2018 By: Marjenah Issapour issapom@farmingdale.edu WATER QUALITY REPORTS Have you looked at your water report? Do you know how to get your drinking water report? How do

More information

OG TAL ODUCT CA PR e e HEALTH

OG TAL ODUCT CA PR e e HEALTH PRODUCT CATALOG e e HEALTH MODEL: OC 5 HEALTH OXYGEN CONCENTRATOR ACCESSORIES FILTER AIR FILTER NASAL CANNULA BUBBLE HUMIDIFIER Oxygen concentrator is a device that generates oxygen with a purity of %90-92

More information

EXPOSURE SCHEDULES FOR SUNTANNING PRODUCTS

EXPOSURE SCHEDULES FOR SUNTANNING PRODUCTS EXPOSURE SCHEDULES FOR SUNTANNING PRODUCTS It is generally accepted that proper use of indoor tanning methods may be safer for the tanner than the uncontrolled environment of outdoor tanning. However,

More information

March 8, DxNow, Inc. Kevin Sly Senior Advisor to DxNow, Inc. 401 Professional Drive, Suite 130 Gaithersburg, Maryland

March 8, DxNow, Inc. Kevin Sly Senior Advisor to DxNow, Inc. 401 Professional Drive, Suite 130 Gaithersburg, Maryland March 8, 2018 Kevin Sly Senior Advisor to 401 Professional Drive, Suite 130 Gaithersburg, Maryland 20879-3429 Re: Trade/Device Name: ZyMot ICSI Sperm Separation Device, ZyMot Multi Sperm Separation Device

More information

Laboratory Safety 197/405. Types of Radiation 198/405

Laboratory Safety 197/405. Types of Radiation 198/405 Laboratory Safety 197/405 Types of Radiation 198/405 Particle Radiation Alpha He nucleus (heavy particle) +2 charge Internal hazard only Beta Electron -1 charge Internal and external hazard Neutron 199/405

More information

PREMIXES FOR MEDICATED FEEDING STUFFS FOR VETERINARY USE. Praeadmixta ad alimenta medicata ad usum veterinarium. Effervescent powders

PREMIXES FOR MEDICATED FEEDING STUFFS FOR VETERINARY USE. Praeadmixta ad alimenta medicata ad usum veterinarium. Effervescent powders Preparations for inhalation administered in or with water or another suitable liquid. They may also be swallowed directly. They are presented as single-dose or multidose preparations. Where applicable,

More information

Qualification of NDT Sensors and Sensor Module used in In-Service Inspection of Coolant Channels of 220 MWe Indian Pressurized Heavy Water Reactors

Qualification of NDT Sensors and Sensor Module used in In-Service Inspection of Coolant Channels of 220 MWe Indian Pressurized Heavy Water Reactors National Seminar & Exhibition on Non-Destructive Evaluation, NDE 2014, Pune, December 4-6, 2014 (NDE-India 2014) Vol.20 No.6 (June 2015) - The e-journal of Nondestructive Testing - ISSN 1435-4934 www.ndt.net/?id=17844

More information

Application Note No. 107/2013 Nitrogen & protein determination in beer and malt KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376:

Application Note No. 107/2013 Nitrogen & protein determination in beer and malt KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376: Application Note No. 107/2013 Nitrogen & protein determination in beer and malt KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376: Accelerated Nitrogen and Protein Determination in Beer and Malt

More information

INTERCHANGEABLE HEAD SYSTEM. Easily and quickly change between caries diagnosis and intraoral imaging. T r i t o n H D

INTERCHANGEABLE HEAD SYSTEM. Easily and quickly change between caries diagnosis and intraoral imaging. T r i t o n H D INTERCHANGEABLE HEAD SYSTEM. Easily and quickly change between caries diagnosis and intraoral imaging. T r i t o n H D Whether its patient education, caries detection or accurate clinical documentation,

More information

User Manual. RaySafe i2 dose viewer

User Manual. RaySafe i2 dose viewer User Manual RaySafe i2 dose viewer 2012.03 Unfors RaySafe 5001048-A All rights are reserved. Reproduction or transmission in whole or in part, in any form or by any means, electronic, mechanical or otherwise,

More information

Efficient Dosimetry for Proton Therapy

Efficient Dosimetry for Proton Therapy Efficient Dosimetry for Proton Therapy Why IBA Dosimetry? IBA Dosimetry offers the full product range tailored to fit any Proton Therapy QA needs. PT treatment safety, as well as most efficient dosimetry

More information

Pille Measurements on ISS (May 2014 March 2015)

Pille Measurements on ISS (May 2014 March 2015) Pille Measurements on ISS (May 2014 March 2015) I. Apáthy 1, A. Hirn 1, S. Deme 1, P. Szántó 1, T. Pázmándi 1 Y. A. Akatov 2, V. V. Arkhangelsky 2, I. Nikolaev 3 1 MTA Centre for Energy Research, Budapest,

More information

Even Moderate Air Pollution Can Raise Stroke Risks

Even Moderate Air Pollution Can Raise Stroke Risks Beth Israel Deaconess Medical Center - A Teaching Hospital of Harvard Medical School Home > News > In Medicine > Even Moderate Air Pollution Can Raise Stroke Risks Even Moderate Air Pollution Can Raise

More information

PHYSICS 2: HSC COURSE 2 nd edition (Andriessen et al) CHAPTER 20 Radioactivity as a diagnostic tool (pages 394-5)

PHYSICS 2: HSC COURSE 2 nd edition (Andriessen et al) CHAPTER 20 Radioactivity as a diagnostic tool (pages 394-5) PHYSICS 2: HSC COURSE 2 nd edition (Andriessen et al) CHAPTER 20 Radioactivity as a diagnostic tool (pages 394-5) 1. (a) A radioisotope is an isotope that is unstable and will emit particles from the nucleus

More information