Assessment of Lower Limb Length and Alignment by Biplanar Linear Radiography: Comparison With Supine CT and Upright Full-Length Radiography

Size: px
Start display at page:

Download "Assessment of Lower Limb Length and Alignment by Biplanar Linear Radiography: Comparison With Supine CT and Upright Full-Length Radiography"

Transcription

1 Musculoskeletal Imaging Original Research Guggenberger et al. Assessment of Lower Limb Length and Alignment Using Different Modalities Downloaded from by on 8/23/18 from IP address Copyright ARRS. For personal use only; all rights reserved Musculoskeletal Imaging Original Research Roman Guggenberger 1 Christian W. A. Pfirrmann 1 Peter P. Koch 2 Florian M. Buck 1 Guggenberger R, Pfirrmann CWA, Koch PP, Buck FM Keywords: biplanar linear x-ray scanner, limb alignment, limb length, supine CT, upright full-length radiography DOI:1.2214/AJR Received February 17, 213; accepted after revision April 24, Department of Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 1, Zurich 891, Switzerland. Address correspondence to R. Guggenberger (roman.guggenberger@usz.ch). 2 Department of Orthopedic Surgery, Balgrist University Hospital, Zurich, Switzerland. WEB This is a web exclusive article. AJR 214; 22:W161 W X/14/222 W161 American Roentgen Ray Society Assessment of Lower Limb Length and Alignment by Biplanar Linear Radiography: Comparison With Supine CT and Upright Full-Length Radiography OBJECTIVE. The purpose of this article is to compare lower limb length and alignment measurements on supine CT, upright full-length radiography, and 3D models based on upright biplanar linear radiography. SUBJECTS AND METHODS. This study involved 51 consecutive patients (22 men and 29 women; mean age, 68.8 years; range, years) who were scheduled for total knee replacement. Lower limb length and alignment angle were measured on CT, upright fulllength radiography, and 3D models based on biplanar linear radiography with standard and composed leg methods by two independent readers. Descriptive statistics of each modality were calculated. Measurements of different modalities were compared by paired Student t tests. Agreement between readers and modalities was assessed by Bland-Altman analyses. RESULTS. Mean (± SD) limb lengths were 783 ± 56.1 mm (range, mm), 785 ± 53. mm (range, mm), 78 ± 55.4 mm (range, mm), and 783 ± 55.9 mm (range, mm) for CT, upright full-length radiography, and 3D models based on biplanar linear radiography standard and composed leg measurements, respectively. Mean alignment angles were 2.3 ± 5.5 (range, 12 to 2 ) for CT, 2.5 ± 6.7 (range, 17 to 18 ) for upright full-length radiography, and 3.4 ± 6.6 (range, 14 to 18 ) for 3D models based on biplanar linear radiography. No significant differences among modalities for mean limb length were found when using composed leg measurements in biplanar linear radiography. Very small but significant mean differences in angle measurements were seen for CT ( 1.1 ± 2.5) and upright full-length radiography (.9 ± 3.1) compared with biplanar linear radiography. Bland-Altman analyses showed no significant differences between readers, with the highest agreement for biplanar linear radiography length measurements. CONCLUSION. Measurements on 3D models based on upright biplanar linear radiographs allow lower limb length and alignment angle measurements that are interchangeable with supine CT scans and upright full-length radiographs but with superior interreader agreement. D ifferences in limb length should be reliably quantified before knee replacement surgery, allowing intraoperative correction and symmetric postoperative length of the lower limbs [1]. In addition, a physiologic alignment should be restored. Postoperative varus or valgus deformity of more than 3 has been shown to markedly reduce the durability of total knee replacements and has been associated with a higher rate of surgical revision procedures [2]. Despite some controversy in the literature, a neutral postoperative limb alignment seems to be beneficial for long-term outcome after total knee prosthesis implantation [3, 4]. Today, several imaging modalities allow length and alignment measurements of the lower limb in either a supine or upright weight- bearing position. The scout view of a supine CT scan may serve as a full-length radiograph but can be acquired only in a non-weight-bearing position. Conventional upright full-length radiography allows weight-bearing upright imaging of the patient but, analogous to supine CT scans, may be associated with measurement errors in cases of rotational misplacement or malpositioning of the lower extremities at the time of image acquisition [5 7]. To assess reliably length and alignment angle of the lower limb, full extension of the knee joint is required. This, however, may be impossible in cases of severe osteoarthritis or contractures of the extensor muscles [8]. Upright biplanar linear radiography with generation of 3D models based on simultaneously acquired frontal and lateral projections AJR:22, February 214 W161

2 Guggenberger et al. Downloaded from by on 8/23/18 from IP address Copyright ARRS. For personal use only; all rights reserved Fig year-old woman with severe osteoarthritis of knee. For all modalities (supine CT scans, upright full-length radiographs, and 3D models based on biplanar linear radiography), lower limb length was measured between center of femoral head and center of superior contour of talar trochlea (left leg). Alignment angle was defined by line through center of femoral head and intercondylar notch of femur and line between intercondylar eminence of tibia and center of ankle joint (right leg). Positive alignment values signified varus alignment, and negative values signified valgus alignment. Fig year-old woman with severe osteoarthritis of knee. A C, Supine CT scout view (A), conventional upright full-length radiograph (B), and upright biplanar linear radiograph (C) of lower limbs are shown. Note slight pelvic rotation to right (A) and stitching artifacts from postprocessing (slight dark horizontal bands, B) whereas homogeneous depiction quality is perceived in panels A and C. Upright linear radiographs from anteroposterior (C) and lateral (not shown) projections were used for generation of 3D models. Measured limb length and alignment angles of both legs in this patient ranged between 721 and 738 mm and 2 valgus for different modalities. allows both upright imaging under weightbearing conditions and the depiction of 3D structures with consecutive compensation of extension deficits in the knee joints or rotation or projection differences occurring in mere 2D projection modalities. Measurements of the lower limb from 3D models based on biplanar linear radiography have already been shown to be comparable to 3D measurements based on CT in pediatric patients [9] and have shown increased accuracy for hip-knee-ankle angle measurements compared with 2D in ex vivo and in vivo conditions [1, 11]. Measurements from 3D models of the legs allow measurement of the limb length in 3D with and without taking account of an extension deficit in the knee joint. Thus, postoperative limb length after implantation of total knee prostheses, which restores full extension in the knee joint, can be estimated. Biplanar linear radiography has therefore gained increasing attention in recent years in both the orthopedic and radiologic communities and may potentially replace traditional modalities for the assessment of lower limb geometry (i.e., length and alignment angle). However, the question arises whether limb length and alignment measurements using 3D models from upright biplanar linear radiographs are interchangeable with measurements on supine CT scans and weight-bearing upright full-length radiographs and whether measurement reliability is superior in patients with severe osteoarthritis of the knee joint. At present, to our knowledge, no comparison has been made between 3D models from upright biplanar linear radiography and projectional 2D modalities in the supine (CT scan) or weight-bearing (upright full-length radiography) position under in vivo conditions. Thus, the purpose of our study was to compare lower limb length and alignment angle measurements using supine CT scout views, weight-bearing upright full-length radiography, and 3D models based on biplanar linear radiography. Subjects and Methods Institutional review board approval was obtained before the start of the study. In total, 59 patients with severe osteoarthritis of the knee scheduled for a total knee replacement were prospectively included after giving their informed consent. Eight patients had to be excluded from data analysis because of missing scaling items or insufficient image quality of upright full-length radiographs. Patients younger than 18 W162 AJR:22, February 214

3 Assessment of Lower Limb Length and Alignment Using Different Modalities Downloaded from by on 8/23/18 from IP address Copyright ARRS. For personal use only; all rights reserved years, patients with Legg-Calvé-Perthes or developmental dysplasia of the hip, and patients who were unable to stand in an upright position would have been excluded also. Eventually, 51 patients (22 men and 29 women; mean age, 68.8 years; range, years) were included in the final data analysis. As a routine preoperative imaging workup, all patients were scheduled for a CT scan of the hip joints, knee joints, and ankle joints for the production of patient-matched cutting blocks for knee prosthesis implantation surgery. The scout views of these CT scans were used for this study. In addition, an upright full-length radiography and a biplanar linear radiography were performed the same day. CT Scans CT scans were performed using a 64-MDCT unit (Brilliance 64, Philips Healthcare). The patient was scanned in the supine position with the feet entering the gantry first. Scans included the entire lower limb from the iliac crests to the soles of the feet. Both legs were composed as much as possible, and care was taken to stabilize them in a neutral position without any rotation. Ankle joints were flexed in 9, and the toes were pointed toward the ceiling. The anteroposterior scout view was acquired using the following settings: scan length, 12 cm; tube voltage, 8 kv; tube current, 3 ma; FOV, 5 mm; and matrix, Upright Full-Length Radiography Upright full-length radiography was performed on a fully digital radiography system (Ysio, Siemens Healthcare). Different preset tube voltages were chosen by the radiology technician according to the patient s stature and weight (small, kv; medium, 77 9 kv; large, kv), and tube currents were set according to automatic exposure measurements. A scaling item (a small radiopaque sphere with a diameter of 2.5 cm) was positioned next to the right lower leg before image acquisitions and was used for image calibration. Biplanar Linear Radiography Anteroposterior and lateral linear radiographs were simultaneously acquired using a biplanar radiography system (EOS, EOS Imaging). The patient was centered in the upright position on the scanner platform. The scan included the whole lower limb from the hip joint to the ankle joint. Tube voltage of the x-ray tubes was chosen by the radiology technician among three different presets, according to the patients weight and stature (small, medium, and large; 8 14 kv with 2 32 ma for anteroposterior projection and 1 12 kv with 2 32 ma for lateral projection). A translational speed of the tubes of 5 was chosen from the vendor-specific scale, ranging from 1 Fig year-old woman with severe osteoarthritis of knee. A and B, Semiautomated generation of 3D model is based on matching of 3D model of femur and tibia with osseous contours of lower limb on frontal and lateral linear radiographs (A). Software requires identification of predefined osseous landmarks (e.g., femoral head, femoral condyles, tibial head, and medial and lateral malleolus) to generate 3D model. This model is then fine-tuned manually. Eventually, 3D limb lengths and limb alignments angle are calculated automatically by software (B). A B AJR:22, February 214 W163

4 Guggenberger et al. Downloaded from by on 8/23/18 from IP address Copyright ARRS. For personal use only; all rights reserved (fast) to 8 (slow). After scanning, the images were sent to an EOS workstation for secondary reconstruction and generation of 3D models. Postprocessing and Measurements CT scout view and full-length radiography The measurements were performed by two independent musculoskeletal radiologists with 3 and 7 years of experience. Lower limb length was defined as the distance from the center of the femoral head to the center of the superior contour of the talar trochlea. Lower limb alignment angle was defined by a line through the center of the femoral head and the intercondylar notch of the femur and a line between the intercondylar eminence of the tibia and the center of the ankle joint [12] (Figs. 1 and 2). Biplanar linear radiography Biplanar linear radiographs were postprocessed using a vendorspecific workstation (stereos, EOS Imaging) by two independent radiology technicians with special training in 3D reconstruction based on biplanar linear radiography. The user of the reconstruction software manually marks predefined osseous landmarks, such as the femoral head, femoral condyles, tibial head, and medial and lateral malleolus. Then the software semiautomatically matches a 3D model of a femur and a tibia to the contour of femur and tibia on the frontal and lateral radiographs. On the basis of this 3D model, measurements of limb length and limb alignment are automatically calculated (Fig. 3). Limb length is calculated as the distance between the center of the femoral head and the center of the superior contour of the talar trochlea in 3D models (standard limb length measurement). In addition, there is another way to measure limb length, with the software taking into account extension deficits, where the limb length is calculated by adding up the 3D lengths of the femur and tibia. We call this measurement method the composed leg limb length measurement. Limb alignment angles, however, remain unchanged. Statistical Analysis All calculations were performed using commercially available software (SPSS Statistics, version 19, IBM). Descriptive statistics (mean [± SD] and range) TABLE 1: Descriptive Statistics of Mean Limb Length and Alignment Measurements for Different Imaging Modalities and Both Readers Reader 1 Reader 2 Imaging Modality Limb Length (mm) Limb Alignment Angle ( ) Limb Length (mm) Limb Alignment Angle ( ) Supine CT scout view 783 ± ± ± ± 5.5 Upright full-length radiographs 785 ± ± ± ± 6.7 Upright biplanar linear radiographs 779 ± ± ± ± 6.6 Composed limb length measurement 783 ± ± 56. Note Data are mean ± SD. were calculated for lower limb length and alignment of the three different modalities and both readers. Interreader agreement and agreements between modalities were assessed by Bland-Altman analysis and paired two-tailed Student t testing. Bland-Altman plots were generated to graphically depict scatter of measurement differences. A p value less than.5 was considered statistically significant. Results Lower Limb Length Mean limb lengths were 783 ± 56.1 mm (range, mm) for CT scout views, 785 ± 53. mm (range, mm) for upright full-length radiographs, and 78 ± 55.4 mm (range, mm) for 3D models based on biplanar linear radiographs (Table 1). Composed leg limb length measurements revealed a mean limb length of 783 ± 55.9 mm (range, mm). Small statistically significant (p <.1) differences were seen among the different modalities for lower limb length measurements. Limb lengths measured using 3D models based on biplanar linear radiographs were significantly shorter than measurements on CT scans and upright full-length radiographs. No differences were seen between limb length measurements on CT scans and upright full-length radiographs (p =.57). On average, limb length measurements using 3D models based on biplanar linear radiographs were 2.7 ± 5.5 mm shorter than measurements on CT scans and 5.4 ± 13.1 mm shorter than measurements performed on upright full-length radiographs. Regarding the composed leg measurement method, no statistically significant differences were seen in comparison with CT scans and biplanar linear radiographs (Table 2). Lower Limb Alignment Mean alignment angles were 2.3 ± 5.5 (range, 12 to 2 ) for CT scout views, 2.5 ± 6.7 (range, 17 to 18 ) for upright full-length radiographs, and 3.4 ± 6.6 (range, 14 to 18 ) for 3D models based on biplanar linear radiographs (Table 1). Small statistically significant (p <.1) differences were seen among the different modalities for angle measurements. Compared with measurements using 3D models based on biplanar linear radiographs, angles measured on CT scans were 1.1 ± 2.5 smaller and measurements on upright fulllength radiographs were.9 ± 3.1 smaller. No differences were seen for alignment measurements between CT scans and upright fulllength radiographs (p =.54) (Table 2). Intermodality Agreement Bland-Altman analyses for comparisons of different modalities showed a constant range of measurement differences and scatter with increasing average for both length and alignment angle measurements. Consistent variability of measurements across all graphs was seen. Further results concerning specific patient subgroups (varus alignment, valgus alignment, varus angle > 1, and valgus angle > 1 as measured on upright fulllength radiography) are shown in Table 2 and Figures 4 and 5. Interreader Agreement Interreader agreement as calculated with Bland-Altman analyses was high and showed no significant differences between both readers in all modalities. The smallest mean lower limb length difference and range between both readers were seen in measurements on 3D models based on biplanar linear radiographs using the composed leg measurement (mean difference,.5 ± 3.4 mm; range, 8 mm) (Table 3). Discussion Despite small statistically significant differences, we found overall clinically comparable lower limb length and alignment angle measurements on supine CT scans, weight-bearing upright full-length radiographs, and biplanar linear radiographs in this study. Although patient posture seems to not significantly affect both measures, Bland-Altman analyses detected small but significant differences between 3D models from weight-bearing bipla- W164 AJR:22, February 214

5 Assessment of Lower Limb Length and Alignment Using Different Modalities Downloaded from by on 8/23/18 from IP address Copyright ARRS. For personal use only; all rights reserved TABLE 2: Bland-Altman Analyses of Measurement Differences in Different Modalities for Limb Length and Alignment Measurements in All Patients and Subanalyses for Patients With,, > 1, and > 1 Upright Full-Length Radiographs vs Upright Biplanar Linear Radiographs Supine CT vs Upright Full-Length Radiographs Supine CT vs Upright Biplanar Linear Radiographs > 1 (n = 4) > 1 (n = 12) > 1 (n = 4) > 1 (n = 12) > 1 (n = 4) > 1 (n = 12) Limb, Measurement Lower limb length (mm) Mean difference ± SD 2.7 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 1 Composed leg length.7 ± ± ± ± ± ± ± ± ± ± 11 95% CI 5.4 to to to to to to to to to 24 Composed leg length 1.7 to to to to to to to to to 7 12 to 23 Minimum, maximum 31, 51 31, 51 19, 18 22, 38 15, 18 21, 19 2, 19 21, 14 4, 19 1, 14 52, 36 52, 36 11, 22 19, 19 5, 2 Composed leg length 26, 1 1, 8 26, 1 1, 8 2, 1 55, 28 55, 28 15, 28 3, 17 9, 18 Range Composed leg length Lower limb alignment angle ( ) Mean difference ± SD.2 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± % CI.9 to.4 2 to to to to to to to to to 1..6 to to 1.6 Minimum, maximum 18, 8 18, 5 1, 8 12, 2 2, 7 7, 8 7, 8 2, 5 6, 2 1, 4 8, 18 8, 18 5, 3 3, 11 3, 1 Range (n = 34) (n = 68) All (n = 12) (n = 34) (n = 68) All (n = 12) (n = 34) (n = 68) All (n = 12) Note Bold type indicates a statistically significant difference (p <.5). nar linear radiography and both other modalities. However, these differences were in the order of magnitude of the measurement accuracies themselves. Interreader agreement was high for all modalities, with the highest agreement seen in lower limb length measurements using 3D models based on biplanar linear radiographs. Upright full-length radiography offers fast depiction of the lower limb in an upright patient position. Technically, it consists of three projections at different angulations that are stitched together and visually corrected by the technician to form a single image. Hence, upright full-length radiographs may, in addition to the impact of posture, be associated with a certain distortion effect when compared with supine CT scans, leading to the observed differences in severe misalignment angles [5 7]. Similarly, low-dose scout views in CT scans are also a projection of 3D structures onto a 2D plane but performed with the patient in a non-weight-bearing supine position. In contrast to upright full-length radiography, CT scout views are not associated with distortion artifacts due to possible stitching errors. Therefore, observed mean differences between both modalities for lower limb length and alignment angles were small (average, 2.7 mm and.2, respectively) and may be considered clinically irrelevant [1, 2]. Interestingly, larger differences of limb alignment angle measurements were seen when comparing supine CT scans to weight-bearing upright full-length radiography in patients with varus or valgus alignment of more than 1 (average, 4.2 for varus angles > 1 and 3.8 for valgus angles < 1 ). This increase in difference between both modalities may be caused by increased lower limb misalignment angles under upright weight-bearing conditions during upright full-length radiography imaging. Therefore, marked varus or valgus deformity posture during imaging seems to increasingly affect measured lower limb alignment angles. Upright biplanar linear radiography with reconstruction of 3D models based on simultaneously acquired contiguous frontal and lateral projections combines the advantage of a physiologic upright weight-bearing position during imaging with the possibility of 3D model generation at a low radiation dose [9, 13]. To be able to generate exact 3D models, the patient needs to be positioned in a small step position to allow delineation of the posterior contour of the femoral condyles of both legs on the lateral view. Overall, limb length measurements were comparable among different modalities, and mean differences were small from a clinical point of view. Limb length measurements on 3D models using standard measurements were, however, significantly smaller compared with supine CT scans and weight-bearing upright full-length radiography. These mean differences increased in patients with severe varus and valgus deformity (average, 4.4 and 5.8 mm, respectively) comparing biplanar linear radiography to CT. Limb length is measured on 3D models as the distance from the center of the femoral head to the center of the upper ankle joint. Thus, flexion of the knee joint at the time of image acquisition leads to a falsely short limb length measurement in these 3D models. The composed leg mea- AJR:22, February 214 W165

6 Guggenberger et al. Downloaded from by on 8/23/18 from IP address Copyright ARRS. For personal use only; all rights reserved A B Difference ( ) D surement method is able to compensate for this error due to an extension deficit in the knee joint, because the individual lengths of femur and tibia of a limb are taken into account and considered for calculation of the true limb length. Consequently, the lower limb length measurements using this method do not significantly differ from other modalities, and the subtle differences observed in the biplanar linear radiography standard measurements disappear. Usually, in the setting of planned total knee replacement, the composed leg measurement method is favored because it provides a more accurate estimation of postoperative lower limb length. Interreader agreement was very high using this method, with a mean difference between readers of only.5 mm. Mean alignment angles on biplanar linear radiography are equally calculated by both techniques and were slightly, but significantly, larger than those measured on supine CT scans and weight-bearing upright full-length radiography (average difference, 1.1 and.9 ). The difference was even larger in patients with varus alignment angles greater than 1 (2.5 and 1.7, respectively). Only in patients with a valgus deformity less than 1 alignment angles on CT scans were the differences larger than on biplanar linear radiography (2.6 ), but because of the small number of patients in this group (n = 4), this finding has Difference ( ) E 2 2 C Fig. 4 Bland-Altman analysis of limb length measurements. A E, Graphs show limb length measurements for all patients for supine CT scout views versus upright full-length radiography (A), supine CT scout views versus biplanar linear radiography (B), upright full-length radiography versus biplanar linear radiography (C), supine CT scout views versus biplanar linear radiography composed leg method (D), and supine CT scout views versus biplanar linear radiography composed leg method (E). Note constant range of measurement differences with increasing average and consistent variability across all graphs. Detailed values are provided in Table to be interpreted with caution. Larger alignment angles in biplanar linear radiography indicate that malrotation of the lower limb may lead to distortion, either in varus or valgus alignment. Maximal and true limb alignment are measured in the frontal plane only in relation to each limb. This measurement plane can be reached only by compensating malrotation of the lower limb, using 3D models based on biplanar linear radiography. These angle measurements may thus be considered as the closest approximation to the true anatomy of the lower limb. According to Fang and Ritter [2], postoperative limb alignment angles in neutral or slight valgus alignment, optimally valgus, are considered to be optimal Average Lower Limb Angle ( ) Average Lower Limb Angle ( ) Average Lower Limb Angle ( ) A B C Difference ( ) Fig. 5 Bland-Altman analysis of limb alignment measurements. A C, Graphs show limb alignment measurements for all patients for supine CT scout views versus upright full-length radiography (A), supine CT scout views versus biplanar linear radiography (B), and upright full-length radiography versus biplanar linear radiography (C). Note constant range of measurement differences with increasing average and consistent variability across all graphs. For detailed values refer to Table 2. W166 AJR:22, February 214

7 Assessment of Lower Limb Length and Alignment Using Different Modalities TABLE 3: Bland-Altman Analyses of Measurement Differences of Both Readers in Different Modalities Limb Length (mm) Limb Alignment Angle ( ) Downloaded from by on 8/23/18 from IP address Copyright ARRS. For personal use only; all rights reserved Upright Upright Biplanar Upright Biplanar Upright Upright Biplanar Full-Length Linear Radiographs, Linear Radiographs, Full-Length Linear Parameter Supine CT Radiographs Standard Composed Supine CT Radiographs Radiographs Mean difference ± SD 1.3 ± ± ± ± ± ± ± % CI.1 to to to. 1.1 to.2.4 to to.1.1 to.4 Minimum, maximum 18, 45 24, 12 16, 4 4, 4 5, 7 5, 5 1, 9 Range Note All modalities showed no significant differences between both readers (p >.5). to ensure long durability of the endoprosthesis. The measured mean angle differences between both readers and the different modalities are well within this recommended angle range and may thus be considered not clinically relevant. We are aware of certain limitations of this study. First, patients have to be able to stand upright in biplanar linear radiography. However, upright imaging also applies to upright full-length radiography, and, in our experience, many patients manage to stand up for a few seconds even if they are dependent on a wheelchair. Second, despite focusing on patients with severe osteoarthritis of the knee, there were not many patients with a significant extension deficit in the knee joint or severe varus or valgus deformity, potentially obscuring a significant advantage of 3D models. Finally, we did not compare radiation dose or time efficiency of the different modalities. Although a thorough evaluation of radiation dose lies beyond the scope of this work, this topic may be crucial in situations of repeated imaging, such as congenital deformities, or preoperative and repeated postoperative follow-up examinations in patients with complicated endoprosthesis surgery for severe osteoarthritis. In conclusion, measurements on 3D models based on upright biplanar linear radiographs allow lower limb length and alignment measurements that are interchangeable with supine CT scans and upright full-length radiographs but with superior interreader agreement. References 1. Lang JE, Scott RD, Lonner JH, Bono JV, Hunter DJ, Li L. Magnitude of limb lengthening after primary total knee arthroplasty. J Arthroplasty 212; 27: Fang D, Ritter MA. Malalignment: forewarned is forearmed. Orthopedics 29; 32:pii 3. Bonner TJ, Eardley WG, Patterson P, Gregg PJ. The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years. J Bone Joint Surg Br 211; 93-B: Parratte S, Pagnano MW, Trousdale RT, Berry DJ. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am 21; 92: Kawakami H, Sugano N, Yonenobu K, et al. Effects of rotation on measurement of lower limb alignment for knee osteotomy. J Orthop Res 24; 22: Radtke K, Becher C, Noll Y, Ostermeier S. Effect of limb rotation on radiographic alignment in total knee arthroplasties. Arch Orthop Trauma Surg 21; 13: Lonner JH, Laird MT, Stuchin SA. Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties. Clin Orthop Relat Res 1996; Myles CM, Rowe PJ, Walker CR, Nutton RW. Knee joint functional range of movement prior to and following total knee arthroplasty measured using flexible electrogoniometry. Gait Posture 22; 16: Gheno R, Nectoux E, Herbaux B, et al. Three-dimensional measurements of the lower extremity in children and adolescents using a low-dose biplanar X-ray device. Eur Radiol 212; 22: Thelen P, Delin C, Folinais D, Radier C. Evaluation of a new low-dose biplanar system to assess lower-limb alignment in 3D: a phantom study. Skeletal Radiol 212; 41: Guenoun B, Zadegan F, Aim F, Hannouche D, Nizard R. Reliability of a new method for lowerextremity measurements based on stereoradiographic three-dimensional reconstruction. Orthop Traumatol Surg Res 212; 98: Sabharwal S, Zhao C, McKeon JJ, McClemens E, Edgar M, Behrens F. Computed radiographic measurement of limb-length discrepancy: full-length standing anteroposterior radiograph compared with scanogram. J Bone Joint Surg Am 26; 88: Janssen MM, Drevelle X, Humbert L, Skalli W, Castelein RM. Differences in male and female spino-pelvic alignment in asymptomatic young adults: a three-dimensional analysis using upright lowdose digital biplanar X-rays. Spine (Phila Pa 1976) 29; 34:E826 E832 AJR:22, February 214 W167

Institutional review board approval was obtained prior to the start of this study.

Institutional review board approval was obtained prior to the start of this study. Lower Limb Alignment and Length Measurements - Comparison of Computed Tomography, Upright Full-Length Conventional Radiography and Upright Biplanar Linear-Low Dose X-ray Scanner Poster No.: C-1382 Congress:

More information

Foot and ankle radiographic parameters: validity and reproducibility of biplane imaging system versus conventional radiography

Foot and ankle radiographic parameters: validity and reproducibility of biplane imaging system versus conventional radiography Foot and ankle radiographic parameters: validity and reproducibility of biplane imaging system versus conventional radiography Chamnanni Rungpai, MD; Jessica E. Goetz, PhD; Marut Arunakul, MD; Yubo, Gao,

More information

Hindfoot Alignment Measurements: Rotation-Stability of Measurement Techniques on Hindfoot Alignment View and Long Axial View Radiographs

Hindfoot Alignment Measurements: Rotation-Stability of Measurement Techniques on Hindfoot Alignment View and Long Axial View Radiographs Musculoskeletal Imaging Original Research Buck et al. Measurements Musculoskeletal Imaging Original Research FOCUS ON: Florian M. Buck 1 Adrienne Hoffmann 1 Nadja Mamisch-Saupe 1 Norman Espinosa 2 Donald

More information

Dora Street, Hurstville 160 Belmore Road, Randwick

Dora Street, Hurstville 160 Belmore Road, Randwick Dr Andreas Loefler www.orthosports.com.au 29 31 Dora Street, Hurstville 160 Belmore Road, Randwick Dr Andreas Loefler Joint Replacement & Spine Surgery CAS or Navigation in TKA New Software for a Full

More information

Evaluation of hindfoot alignment change before and after total knee arthroplasty

Evaluation of hindfoot alignment change before and after total knee arthroplasty Evaluation of hindfoot alignment change before and after total knee arthroplasty Ohashi S, Ikoma K, Hara Y, Arai Y Nagasawa K, Maki M, Kubo T Department of Orthopaedics, Graduate School of Medical Science,

More information

2017 Resident Advanced Trauma Techniques Course COMPLICATIONS / CHALLENGES MALUNIONS/DEFORMITY

2017 Resident Advanced Trauma Techniques Course COMPLICATIONS / CHALLENGES MALUNIONS/DEFORMITY 2017 Resident Advanced Trauma Techniques Course COMPLICATIONS / CHALLENGES MALUNIONS/DEFORMITY What is a Malunion? Definition: a fracture that has healed in a nonanatomic (i.e. deformed) position Must

More information

Multiapical Deformities p. 97 Osteotomy Concepts and Frontal Plane Realignment p. 99 Angulation Correction Axis (ACA) p. 99 Bisector Lines p.

Multiapical Deformities p. 97 Osteotomy Concepts and Frontal Plane Realignment p. 99 Angulation Correction Axis (ACA) p. 99 Bisector Lines p. Normal Lower Limb Alignment and Joint Orientation p. 1 Mechanical and Anatomic Bone Axes p. 1 Joint Center Points p. 5 Joint Orientation Lines p. 5 Ankle p. 5 Knee p. 5 Hip p. 8 Joint Orientation Angles

More information

Comparison of high-flex and conventional implants for bilateral total knee arthroplasty

Comparison of high-flex and conventional implants for bilateral total knee arthroplasty ISPUB.COM The Internet Journal of Orthopedic Surgery Volume 14 Number 1 Comparison of high-flex and conventional implants for bilateral total knee arthroplasty C Martin-Hernandez, M Guillen-Soriano, A

More information

Abramsohn Retractor 1

Abramsohn Retractor 1 Abramsohn Retractor 1 Calibrated Femoral Tibial Spreaders Small Medium Large Designed to remain in position, with the femur and tibia separated, without the need of an assistant, and to minimize crushing

More information

BIOMECHANICAL EXAMINATION OF THE PEDIATRIC LOWER EXTREMITY

BIOMECHANICAL EXAMINATION OF THE PEDIATRIC LOWER EXTREMITY BIOMECHANICAL EXAMINATION OF THE PEDIATRIC LOWER EXTREMITY B.Resseque, D.P.M. ARCH HEIGHT OFF WEIGHTBEARING Evaluate arch height by placing a ruler from the heel to the first metatarsal head Compare arch

More information

A technique for calculating limb length inequality and epiphyseodesis timing using the multiplier method and a spreadsheet

A technique for calculating limb length inequality and epiphyseodesis timing using the multiplier method and a spreadsheet J Child Orthop (2007) 1:151 155 DOI 10.1007/s11832-007-0016-6 TECHNICAL NOTE A technique for calculating limb length inequality and epiphyseodesis timing using the multiplier method and a spreadsheet James

More information

CORRECTIVE OSTEOTOMY BRINGING THE PLAN TO THE BONE (TRIGONOMETERY, GUIDE WIRES, SLA MODELING AND ART)

CORRECTIVE OSTEOTOMY BRINGING THE PLAN TO THE BONE (TRIGONOMETERY, GUIDE WIRES, SLA MODELING AND ART) CORRECTIVE OSTEOTOMY BRINGING THE PLAN TO THE BONE (TRIGONOMETERY, GUIDE WIRES, SLA MODELING AND ART) Randy J. Boudrieau, DVM, DACVS, DECVS Cummings School of Veterinary Medicine at Tufts University, North

More information

Ye-Ran Li, Yu-Hang Gao, Xin Qi *, Jian-Guo Liu, Lu Ding, Chen Yang, Zheng Zhang and Shu-Qiang Li

Ye-Ran Li, Yu-Hang Gao, Xin Qi *, Jian-Guo Liu, Lu Ding, Chen Yang, Zheng Zhang and Shu-Qiang Li Li et al. Journal of Orthopaedic Surgery and Research (2017) 12:92 DOI 10.1186/s13018-017-0588-x RESEARCH ARTICLE Open Access Analysis of factors that affect the precision of the radiographic lateral femoral

More information

SEVERE VARUS AND VALGUS DEFORMITIES TREATED BY TOTAL KNEE ARTHROPLASTY

SEVERE VARUS AND VALGUS DEFORMITIES TREATED BY TOTAL KNEE ARTHROPLASTY SEVERE VARUS AND VALGUS DEFORMITIES TREATED BY TOTAL KNEE ARTHROPLASTY Th. KARACHALIOS, P. P. SARANGI, J. H. NEWMAN From Winford Orthopaedic Hospital, Bristol, England We report a prospective case-controlled

More information

Alignment of the femoral component in a mobile-bearing unicompartmental knee arthroplasty Kort, N. P.; van Raay, J. J. A. M.; Thomassen, B. J. W.

Alignment of the femoral component in a mobile-bearing unicompartmental knee arthroplasty Kort, N. P.; van Raay, J. J. A. M.; Thomassen, B. J. W. University of Groningen Alignment of the femoral component in a mobile-bearing unicompartmental knee arthroplasty Kort, N. P.; van Raay, J. J. A. M.; Thomassen, B. J. W. Published in: Knee DOI: 10.1016/j.knee.2007.04.007

More information

Imaging assessment of Unicomp candidates!

Imaging assessment of Unicomp candidates! 7th Advanced Course on Knee Surgery - 2018: Imaging assessment of Unicomp candidates! Presenter: Anders Troelsen, MD, ph.d., dr.med., Professor Distribution of the basic primary OA patterns Medial FT:

More information

A study of functional outcome after Primary Total Knee Arthroplasty in elderly patients

A study of functional outcome after Primary Total Knee Arthroplasty in elderly patients Original Research Article A study of functional outcome after Primary Total Knee Arthroplasty in elderly patients Ragesh Chandran 1*, Sanath K Shetty 2, Ashwin Shetty 3, Bijith Balan 1, Lawrence J Mathias

More information

Clinical Study Accuracy of Implant Placement Utilizing Customized Patient Instrumentation in Total Knee Arthroplasty

Clinical Study Accuracy of Implant Placement Utilizing Customized Patient Instrumentation in Total Knee Arthroplasty Hindawi Publishing Corporation Advances in Orthopedics Volume 2013, Article ID 891210, 6 pages http://dx.doi.org/10.1155/2013/891210 Clinical Study Accuracy of Implant Placement Utilizing Customized Patient

More information

ANATOMIC. Navigated Surgical Technique 4 in 1 TO.G.GB.016/1.0

ANATOMIC. Navigated Surgical Technique 4 in 1 TO.G.GB.016/1.0 ANATOMIC Navigated Surgical Technique 4 in 1 TO.G.GB.016/1.0 SCREEN LAYOUT Take screenshot Surgical step Dynamic navigation zone Information area and buttons 2 SCREEN LAYOUT Indicates action when yellow

More information

CLINICAL PAPER / ORTHOPEDIC

CLINICAL PAPER / ORTHOPEDIC HIP LEG LENGTH AND OFFSET Kelley T.C. and Swank M.L. (2009) Using CAS leads to more accurate positioning within the safe zone (inclination between 30 and 50, anteversion between 5 and 25 ) CAS improves

More information

Duration of Follow-up (mo)

Duration of Follow-up (mo) Page 1 of 7 Fig. E-1 Fig. E-2 Fig. E-1 Medial ankle arthritis with medial translation of the talus and mortise widening. Note the shape of the medial malleolus (white arrow). Fig. E-2 Measurement of mortise

More information

BIOMECHANICAL MECHANISMS FOR DAMAGE: RETRIEVAL ANALYSIS AND COMPUTATIONAL WEAR PREDICTIONS IN TOTAL KNEE REPLACEMENTS

BIOMECHANICAL MECHANISMS FOR DAMAGE: RETRIEVAL ANALYSIS AND COMPUTATIONAL WEAR PREDICTIONS IN TOTAL KNEE REPLACEMENTS Journal of Mechanics in Medicine and Biology Vol. 5, No. 3 (2005) 469 475 c World Scientific Publishing Company BIOMECHANICAL MECHANISMS FOR DAMAGE: RETRIEVAL ANALYSIS AND COMPUTATIONAL WEAR PREDICTIONS

More information

CT Evaluation of Patellar Instability

CT Evaluation of Patellar Instability CT Evaluation of Patellar Instability Poster No.: C-2157 Congress: ECR 2014 Type: Educational Exhibit Authors: R. Ruef, C. Edgar, C. Lebedis, A. Guermazi, A. Kompel, A. Murakami; Boston, MA/US Keywords:

More information

The Leg Length Discrepancy in The Entire Lower Limbs after Total Hip Arthroplasty Influences The Coronal Alignment of Pelvis and Spine.

The Leg Length Discrepancy in The Entire Lower Limbs after Total Hip Arthroplasty Influences The Coronal Alignment of Pelvis and Spine. The Leg Length Discrepancy in The Entire Lower Limbs after Total Hip Arthroplasty Influences The Coronal Alignment of Pelvis and Spine. Hiroshi Fujimaki, MD 1, Yutaka Inaba, MD, PhD 2, Naomi Kobayashi,

More information

Case Report. Antegrade Femur Lengthening with the PRECICE Limb Lengthening Technology

Case Report. Antegrade Femur Lengthening with the PRECICE Limb Lengthening Technology Case Report Antegrade Femur Lengthening with the PRECICE Limb Lengthening Technology S. Robert Rozbruch, MD Hospital for Special Surgery New York, NY, USA ABSTRACT This is a case illustrating a 4.5 cm

More information

Impact of knee varus and valgus deformity on alignment in lower extremities after total knee arthroplasty (TKA)

Impact of knee varus and valgus deformity on alignment in lower extremities after total knee arthroplasty (TKA) European Review for Medical and Pharmacological Sciences 2018; 22 (1 Suppl): 83-89 Impact of knee varus and valgus deformity on alignment in lower extremities after total knee arthroplasty (TKA) F. TIAN

More information

Kinematic vs. mechanical alignment: What is the difference?

Kinematic vs. mechanical alignment: What is the difference? Kinematic vs. mechanical alignment: What is the difference? In this 4 Questions interview, Stephen M. Howell, MD, explains the potential benefits of 3D alignment during total knee replacement. Introduction

More information

Axial alignment of the lower extremity in Chinese adults. Journal Of Bone And Joint Surgery - Series A, 2000, v. 82 n. 11, p.

Axial alignment of the lower extremity in Chinese adults. Journal Of Bone And Joint Surgery - Series A, 2000, v. 82 n. 11, p. Title Axial alignment of the lower extremity in Chinese adults Author(s) Tang, WM; Zhu, YH; Chiu, KY Citation Journal Of Bone And Joint Surgery - Series A, 2000, v. 82 n. 11, p. 1603-1608 Issued Date 2000

More information

The value of weight-bearing functional CT scans

The value of weight-bearing functional CT scans The value of weight-bearing functional scans In musculoskeletal medicine, advanced imaging like computed axial tomography () scanning, has become invaluable to the evaluation and management of patients

More information

Predicting the Position of the Femoral Head Center

Predicting the Position of the Femoral Head Center The Journal of Arthroplasty Vol. 14 No. 1 1999 Predicting the Position of the Femoral Head Center Nobuhiko Sugano, MD, Philip C. Noble, PhD, and Emir Kamaric, MS Abstract: To find an accurate method to

More information

Total Hip Arthroplasty Performed Using Conventional and Computer-Assisted, Tissue- Preserving Techniques 6

Total Hip Arthroplasty Performed Using Conventional and Computer-Assisted, Tissue- Preserving Techniques 6 Total Hip Arthroplasty Performed Using Conventional and Computer-Assisted, Tissue- Preserving Techniques 6 Stephen B. Murphy, MD, Timo M. Ecker, MD and Moritz Tannast, MD Introduction Less invasive techniques

More information

A comparative assessment of alternatives to the full-leg radiograph for determining knee joint alignment

A comparative assessment of alternatives to the full-leg radiograph for determining knee joint alignment Navali et al. Sports Medicine, Arthroscopy, Rehabilitation, Therapy & Technology 2012, 4:40 RESEARCH Open Access A comparative assessment of alternatives to the full-leg radiograph for determining knee

More information

Femoral Torsion: Impact of Femur Position on CT and Stereoradiography Measurements

Femoral Torsion: Impact of Femur Position on CT and Stereoradiography Measurements Musculoskeletal Imaging Original Research Effect of Femur Position on CT and Stereoradiography Measurements of Femoral Torsion Musculoskeletal Imaging Original Research Gérard Morvan 1 Henri Guerini Grégory

More information

B. CT protocols for the spine

B. CT protocols for the spine B. CT protocols for the spine Poster No.: A-003 Congress: ECR 2010 Type: Invited Speaker Topic: Neuro Authors: B. Tins; Oswestry/UK Keywords: CT, spine, diagnostic imaging protocol DOI: 10.1594/ecr2010/A-003

More information

OrthoMap Express Knee Product Guide. OrthoMap Express Knee Navigation Software 2.0

OrthoMap Express Knee Product Guide. OrthoMap Express Knee Navigation Software 2.0 OrthoMap Express Knee Product Guide OrthoMap Express Knee Navigation Software 2.0 Product Guide 1 Introduction Introduction The Stryker OrthoMap Express Knee Navigation System is providing surgeons with

More information

AFTER TOTAL KNEE REPLACEMENT

AFTER TOTAL KNEE REPLACEMENT CORONAL ALIGNMENT AFTER TOTAL KNEE REPLACEMENT ROBERT S. JEFFERY, RICHARD W. MORRIS, ROBIN A. DENHAM From Queen Alexandra Hospital, Portsmouth Maquet s line passes from the centre of the femoral head to

More information

VARIABILITY OF THE POSTERIOR CONDYLAR ANGLE

VARIABILITY OF THE POSTERIOR CONDYLAR ANGLE VARIABILITY OF THE POSTERIOR CONDYLAR ANGLE Łukasz Cieliński, Damian Kusz, Michał Wójcik Department of Orthopedics Medical University of Silesia in Katowice Introduction Correct positioning of implants

More information

Overview. Acceptance criteria for all protocols

Overview. Acceptance criteria for all protocols X-Ray protocol Overview The Smith & Nephew VISIONAIRE X-Ray protocol is essentially an AP leg length image. The images are preferred to be done erect, but can be done supine if necessary due to the type

More information

)116( COPYRIGHT 2016 BY THE ARCHIVES OF BONE AND JOINT SURGERY

)116( COPYRIGHT 2016 BY THE ARCHIVES OF BONE AND JOINT SURGERY )116( COPYRIGHT 2016 BY THE ARCHIVES OF BONE AND JOINT SURGERY RESEARCH ARTICLE Analysis of the Geometry of the Distal Femur and Proximal Tibia in the Osteoarthritic Knee: A 3D Reconstruction CT Scan Based

More information

Proteus XR/f Patient positioning guide

Proteus XR/f Patient positioning guide Proteus XR/f Patient positioning guide PROTEUS XR/F Now a single digital x-ray room accommodates nearly all your radiographic studies. With extended tube coverage and wireless detectors, Proteus XR/f gives

More information

Bioscience Research Print ISSN: Online ISSN:

Bioscience Research Print ISSN: Online ISSN: Available online freely at www.isisn.org Bioscience Research Print ISSN: 1811-9506 Online ISSN: 2218-3973 Journal by Innovative Scientific Information & Services Network RESEARCH ARTICLE BIOSCIENCE RESEARCH,

More information

RADIOGRAPHY OF THE ANKLE and LOWER LEG

RADIOGRAPHY OF THE ANKLE and LOWER LEG RADIOGRAPHY OF THE ANKLE and LOWER LEG Patient Position: ANKLE AP Projection Part Position: True Slight to place foot s long axis Center to Central Ray: to IR Midway Note: Ankle joint is to tips of malleoli

More information

Leg Length Discrepancy in a Patient with Ipsilateral Total Knee and Total Hip Arthroplasty

Leg Length Discrepancy in a Patient with Ipsilateral Total Knee and Total Hip Arthroplasty texas orthopaedic journal CASE REPORT Leg Length Discrepancy in a Patient with Ipsilateral Total Knee and Total Hip Arthroplasty Gaurav S. Sharma, BA; Ronald W. Lindsey, MD Department of Orthopaedic Surgery

More information

Three-dimensional Effect of the Single Plane Proximal Femur Osteotomy

Three-dimensional Effect of the Single Plane Proximal Femur Osteotomy ORIGINAL ARTICLE Hip Pelvis 27(1): 23-29, 2015 http://dx.doi.org/10.5371/hp.2015.27.1.23 Print ISSN 2287-3260 Online ISSN 2287-3279 Three-dimensional Effect of the Single Plane Proximal Femur Osteotomy

More information

Overview. Acceptance criteria for all protocols

Overview. Acceptance criteria for all protocols X-Ray protocol Overview The Smith & Nephew VISIONAIRE X-Ray protocol is essentially an AP leg length image. The images are preferred to be done erect, but can be done supine if necessary due to the type

More information

A Comparison of Plain Radiography with Computer Tomography in Determining Coronal and Sagittal Alignments following Total Knee Arthroplasty

A Comparison of Plain Radiography with Computer Tomography in Determining Coronal and Sagittal Alignments following Total Knee Arthroplasty Doi: http://dx.doi.org/10.5704/moj.1707.006 A Comparison of Plain Radiography with Computer Tomography in Determining Coronal and Sagittal Alignments following Total Knee Arthroplasty Solayar GN, FRCS

More information

The UniSpacer : correcting varus malalignment in medial gonarthrosis

The UniSpacer : correcting varus malalignment in medial gonarthrosis DOI 10.1007/s00264-009-0908-9 ORIGINAL PAPER The UniSpacer : correcting varus malalignment in medial gonarthrosis Michael Clarius & Justus F. Becker & Holger Schmitt & Joern B. Seeger Received: 20 October

More information

A Kinematic Assessment of Knee Prosthesis from Fluoroscopy Images

A Kinematic Assessment of Knee Prosthesis from Fluoroscopy Images Memoirs of the Faculty of Engineering, Kyushu University, Vol. 68, No. 1, March 2008 A Kinematic Assessment of Knee Prosthesis from Fluoroscopy Images by Mohammad Abrar HOSSAIN *, Michihiko FUKUNAGA and

More information

Analysis of 3D Foot Shape Features in Elderly with Hallux Valgus Using Multi-Dimensional Scaling Method

Analysis of 3D Foot Shape Features in Elderly with Hallux Valgus Using Multi-Dimensional Scaling Method Asian Workshop on D Body Scanning Technologies, Tokyo, Japan, 7-8 April Analysis of D Foot Shape Features in Elderly with Hallux Valgus Using Multi-Dimensional Scaling Method SungHyek KIM Health Science

More information

The radiologist and the raiders of the lost image

The radiologist and the raiders of the lost image The radiologist and the raiders of the lost image Poster No.: P-0072 Congress: ESSR 2014 Type: Educational Poster Authors: M. J. Ereño Ealo, E. Montejo Rodrigo, B. Sancho, E. Pastor; Galdakao/ES Keywords:

More information

Ankle Valgus in Cerebral Palsy

Ankle Valgus in Cerebral Palsy Ankle Valgus in Cerebral Palsy Freeman Miller Contents Introduction... 2 Natural History... 2 Treatment... 3 Diagnostic Evaluations... 3 Indications for Intervention... 3 Outcome of Treatment... 5 Complications

More information

PROPHECY INBONE. Preoperative Navigation Guides

PROPHECY INBONE. Preoperative Navigation Guides PROPHECY INBONE Preoperative Navigation Guides Simple. Fast. Accurate. Simple. Fast. Accurate. Prophecy Envision the Results PROPHECY Preoperative Navigation Guides have ushered in a new era of total ankle

More information

Relationship between Lateral Femoral Bowing and Varus Knee Deformity Based on Two-Dimensional Assessment of Side-to-Side Differences

Relationship between Lateral Femoral Bowing and Varus Knee Deformity Based on Two-Dimensional Assessment of Side-to-Side Differences Original Article Knee Surg Relat Res 2018;30(1):58-63 https://doi.org/10.5792/ksrr.17.007 pissn 2234-0726 eissn 2234-2451 Knee Surgery & Related Research Relationship between Lateral Femoral Bowing and

More information

Preliminary Outcome Using a New Free Motion Offloading KAFO for Postoperative Management of Hemiepiphysiodesis in Adolescent Tibia Vara

Preliminary Outcome Using a New Free Motion Offloading KAFO for Postoperative Management of Hemiepiphysiodesis in Adolescent Tibia Vara Preliminary Outcome Using a New Free Motion Offloading KAFO for Postoperative Management of Hemiepiphysiodesis in Adolescent Tibia Vara Joseph W. Whiteside CO/LO 1399 E. Western Reserve Road, Poland, OH

More information

Klinikum rechts der Isar, Munich - Germany plans orthopedic surgeries with medicad

Klinikum rechts der Isar, Munich - Germany plans orthopedic surgeries with medicad Klinikum rechts der Isar, Munich - Germany plans orthopedic surgeries with medicad A report by Dr. Franz Liska and Dr. Kay Eichelberg, Klinikum rechts der Isar, TU München Should operations be planned

More information

Lower Extremity Alignment: Genu Varum / Valgum

Lower Extremity Alignment: Genu Varum / Valgum Lower Extremity Alignment: Genu Varum / Valgum Arthur B Meyers, MD Nemours Children s Hospital & Health System Associate Professor of Radiology, University of Central Florida Clinical Associate Professor

More information

PRE & POST OPERATIVE RADIOLOGICAL ASSESSMENT IN TOTAL KNEE REPLACEMENT. Dr. Divya Rani K 2 nd Year Resident Dept. of Radiology

PRE & POST OPERATIVE RADIOLOGICAL ASSESSMENT IN TOTAL KNEE REPLACEMENT. Dr. Divya Rani K 2 nd Year Resident Dept. of Radiology PRE & POST OPERATIVE RADIOLOGICAL ASSESSMENT IN TOTAL KNEE REPLACEMENT Dr. Divya Rani K 2 nd Year Resident Dept. of Radiology PRE OPERATIVE ASSESSMENT RADIOGRAPHS Radiographs are used for assessment and

More information

RADIOGRAPHY OF THE KNEE, PATELLA, and FEMUR

RADIOGRAPHY OF THE KNEE, PATELLA, and FEMUR RADIOGRAPHY OF THE KNEE, PATELLA, and FEMUR KNEE AP Projection Patient Position: Part Position: Leg in Center Femoral condyles Central Ray: - Asthenic patient - if ASIS to tabletop is < 19 cm Sthenic patient

More information

Effect of Superior Placement of the Hip Center on Abductor Muscle Strength in Total Hip Arthroplasty

Effect of Superior Placement of the Hip Center on Abductor Muscle Strength in Total Hip Arthroplasty The Journal of Arthroplasty Vol. 24 No. 2 2009 Effect of Superior Placement of the Hip Center on Abductor Muscle Strength in Total Hip Arthroplasty Takahiko Kiyama, MD, Masatoshi Naito, MD, PhD, Hiroshi

More information

PediLoc Extension Osteotomy Plate (PLEO)

PediLoc Extension Osteotomy Plate (PLEO) PediLoc Extension Osteotomy Plate (PLEO) Left PLEO Plates Sizes: 6, 8 and 10 hole plates Right PLEO Plates Sizes: 6, 8 and 10 hole plates PediLoc Extension Osteotomy Plate The technique description herein

More information

Metal Artifact Reduction by Dual Energy CT

Metal Artifact Reduction by Dual Energy CT Metal Artifact Reduction by Dual Energy CT Poster No.: C-0108 Congress: ECR 2011 Type: Authors: Keywords: DOI: Scientific Paper T. Johnson, F. Bamberg, A. Dierks, H.-C. Becker, M. F. Reiser; Munich/DE

More information

BIOMECHANICAL EXAMINATION OF THE PEDIATRIC LOWER EXTREMITY 2017

BIOMECHANICAL EXAMINATION OF THE PEDIATRIC LOWER EXTREMITY 2017 BIOMECHANICAL EXAMINATION OF THE PEDIATRIC LOWER EXTREMITY 2017 B. RESSEQUE, D.P.M., D.A.B.P.O. Professor, N.Y. College of Podiatric Medicine ARCH HEIGHT OFF WEIGHTBEARING Evaluate arch height by placing

More information

2

2 1 2 3 4 5 6 7 8 9 10 11 12 13 Cine loop of tomosynthesis slice images through the chest. 14 Standard PA chest radiograph (left) and single slice from the tomosynthesis image dataset (right) of a patient

More information

Navigation for total hip arthroplasty

Navigation for total hip arthroplasty Interact Surg (2008) 3: 128 134 Springer 2008 DOI 10.1007/s11610-008-0084-4 ORIGINAL ARTICLE Navigation for total hip arthroplasty O. Guyen 1,V.Pibarot 1, J. Bejui-Hugues 2,SCORGroup 1 Service de chirurgie

More information

This is an author-deposited version published in: Handle ID:.http://hdl.handle.net/10985/8923

This is an author-deposited version published in:  Handle ID:.http://hdl.handle.net/10985/8923 Science Arts & Métiers (SAM) is an open access repository that collects the work of Arts et Métiers ParisTech researchers and makes it freely available over the web where possible. This is an author-deposited

More information

Kinematics Analysis of Different Types of Prosthesis in Total Knee Arthroplasty with a Navigation System

Kinematics Analysis of Different Types of Prosthesis in Total Knee Arthroplasty with a Navigation System Showa Univ J Med Sci 29 3, 289 296, September 2017 Original Kinematics Analysis of Different Types of Prosthesis in Total Knee Arthroplasty with a Navigation System Hiroshi TAKAGI 1 2, Soshi ASAI 1, Atsushi

More information

ORIGINAL PAPER. Department of Hand Surgery, Nagoya University School of Medicine ABSTRACT

ORIGINAL PAPER. Department of Hand Surgery, Nagoya University School of Medicine ABSTRACT Nagoya J. Med. Sci. 74. 167 ~ 171 2012 ORIGINAL PAPER TILT OF THE RADIUS FROM FOREARM ROTATIONAL AXIS RELIABLY PREDICTS ROTATIONAL IMPROVEMENT AFTER CORRECTIVE OSTEOTOMY FOR MALUNITED FOREARM FRACTURES

More information

Preoperative Planning. The primary objectives of preoperative planning are to:

Preoperative Planning. The primary objectives of preoperative planning are to: Preoperative Planning The primary objectives of preoperative planning are to: - Determine preoperative leg length discrepancy. - Assess acetabular component size and placement. - Determine femoral component

More information

Hip ultrasound for developmental dysplasia: the 50% rule

Hip ultrasound for developmental dysplasia: the 50% rule Pediatr Radiol (2017) 47:817 821 DOI 10.1007/s00247-017-3802-4 COMMENTARY Hip ultrasound for developmental dysplasia: the 50% rule H. Theodore Harcke 1 & B. Pruszczynski 2 Received: 27 October 2016 /Revised:

More information

Radiographic Positioning Summary (Basic Projections RAD 222)

Radiographic Positioning Summary (Basic Projections RAD 222) Lower Extremity Radiographic Positioning Summary (Basic Projections RAD 222) AP Pelvis AP Hip (Unilateral) (L or R) AP Femur Mid and distal AP Knee Lateral Knee Pt lies supine on table Align MSP to Center

More information

Accuracy and validity of Kinetisense joint measures for cardinal movements, compared to current experimental and clinical gold standards.

Accuracy and validity of Kinetisense joint measures for cardinal movements, compared to current experimental and clinical gold standards. Accuracy and validity of Kinetisense joint measures for cardinal movements, compared to current experimental and clinical gold standards. Prepared by Engineering and Human Performance Lab Department of

More information

A Non-CT Based Total Knee Arthroplasty System Featuring Complete Soft-Tissue Balancing

A Non-CT Based Total Knee Arthroplasty System Featuring Complete Soft-Tissue Balancing A Non-CT Based Total Knee Arthroplasty System Featuring Complete Soft-Tissue Balancing Manuela Kunz 1, Matthias Strauss 2, Frank Langlotz 1, Georg Deuretzbacher 2, Wolfgang Rüther 2, and Lutz-Peter Nolte

More information

Over 20 Years of Proven Clinical Success. Zimmer Natural-Knee II System

Over 20 Years of Proven Clinical Success. Zimmer Natural-Knee II System Over 20 Years of Proven Clinical Success Zimmer Natural-Knee II System CSTi Porous Coating Structurally similar to human bone CSTi porous coating combines the excellent biocompatibility of titanium with

More information

PROPHECY. Preoperative Navigation Guides ANKLE CT SCAN PROTOCOL

PROPHECY. Preoperative Navigation Guides ANKLE CT SCAN PROTOCOL PROPHECY Preoperative Navigation Guides ANKLE CT SCAN PROTOCOL 90 FIGURE 1 Examples FIGURE 1 Examples of neutral ankle positioning. PROPHECY Ankle CT Scan Protocol PROPHECY INBONE and PROPHECY INFINITY

More information

Total Knee Original System Primary Surgical Technique

Total Knee Original System Primary Surgical Technique Surgical Procedure Total Knee Original System Primary Surgical Technique Where as a total hip replacement is primarily a bony operation, a total knee replacement is primarily a soft tissue operation. Excellent

More information

THE KNEE SOCIETY VIRTUAL FELLOWSHIP

THE KNEE SOCIETY VIRTUAL FELLOWSHIP THE KNEE SOCIETY VIRTUAL FELLOWSHIP CHAPTER 2: RADIOGRAPHIC EVALUATION OF THE KNEE Radiographic Evaluation of the Knee Presented by: R. Michael Meneghini, MD COPYRIGHT 2016 THE KNEE SOCIETY Disclosures

More information

Digital Templating of the Non-Affected Hip as a Means of Minimizing Leg-Length Discrepancy after Primary Total Hip Arthroplasty

Digital Templating of the Non-Affected Hip as a Means of Minimizing Leg-Length Discrepancy after Primary Total Hip Arthroplasty Digital Templating of the Non-Affected Hip as a Means of Minimizing Leg-Length Discrepancy after Primary Total Hip Arthroplasty Todd V. Swanson, MD 1 Jonathon M. Brown, BS 1 Siva K. Mamillapalli, MBBS,

More information

ORTHOSCAN MOBILE DI POSITIONING GUIDE

ORTHOSCAN MOBILE DI POSITIONING GUIDE ORTHOSCAN MOBILE DI POSITIONING GUIDE Table of Contents SHOULDER A/P of Shoulder... 4 Tangential (Y-View) of Shoulder... 5 Lateral of Proximal Humerus... 6 ELBOW A/P of Elbow... 7 Extended Elbow... 8 Lateral

More information

Evaluation of Gait Mechanics Using Computerized Plantar Surface Pressure Analysis and it s Relation to Common Musculoskeletal Problems

Evaluation of Gait Mechanics Using Computerized Plantar Surface Pressure Analysis and it s Relation to Common Musculoskeletal Problems Evaluation of Gait Mechanics Using Computerized Plantar Surface Pressure Analysis and it s Relation to Common Musculoskeletal Problems Laws of Physics effecting gait Ground Reaction Forces Friction Stored

More information

Innovations 2017 & 2018

Innovations 2017 & 2018 Innovations 2017 & 2018 medicad 5.0 Hip 3D Spine 3D Knee 3D Shoulder 3D The Orthopedic Solution medicad Version 5.0 CHECK OUT WHAT'S NEW: Hip Automatic measuring of femoral or acetabular offset Automated

More information

In Vivo Kinematic Analysis of the Hip during Activities of Daily Living.

In Vivo Kinematic Analysis of the Hip during Activities of Daily Living. In Vivo Kinematic Analysis of the Hip during Activities of Daily Living. Daisuke Hara 1, Yasuharu Nakashima 1, Satoshi Hamai 1, Hidehiko Higaki 2, Takeshi Shimoto 3, Satoru Ikebe 2, Mio Akiyama 1, Masanobu

More information

Tibial deformity correction by Ilizarov method

Tibial deformity correction by Ilizarov method International Journal of Research in Orthopaedics http://www.ijoro.org Case Report DOI: http://dx.doi.org/10.18203/issn.2455-4510.intjresorthop20180422 Tibial deformity correction by Ilizarov method Robert

More information

Total knee arthroplasty (TKA) is an increasingly. Radiographic Evaluation of Alignment Following TKA, a Systematic Review

Total knee arthroplasty (TKA) is an increasingly. Radiographic Evaluation of Alignment Following TKA, a Systematic Review Mædica - a Journal of Clinical Medicine MAEDICA a Journal of Clinical Medicine 2017; 12(3): 214-218 REVIEW Radiographic Evaluation of Alignment Following TKA, a Systematic Review Serban DRAGOSLOVEANU a,

More information

Balanced Body Movement Principles

Balanced Body Movement Principles Balanced Body Movement Principles How the Body Works and How to Train it. Module 3: Lower Body Strength and Power Developing Strength, Endurance and Power The lower body is our primary source of strength,

More information

Gentle Guided Growth to Correct Knock Knees and Bowed Legs in Children

Gentle Guided Growth to Correct Knock Knees and Bowed Legs in Children PATIENT INFORMATION Gentle Guided Growth to Correct Knock Knees and Bowed Legs in Children The Guided Growth System eight-plate quad-plate INTRODUCTION Children need gentle guidance and correction in many

More information

X-ray (Radiography) - Bone

X-ray (Radiography) - Bone Scan for mobile link. X-ray (Radiography) - Bone Bone x-ray uses a very small dose of ionizing radiation to produce pictures of any bone in the body. It is commonly used to diagnose fractured bones or

More information

Radiographic Assessment of Pediatric Foot Alignment: Self-Assessment Module

Radiographic Assessment of Pediatric Foot Alignment: Self-Assessment Module 1.5 CME AJR Integrative Imaging LIFELONG LEARNING FOR RADIOLOGY Radiographic Assessment of Pediatric Foot Alignment: Self-Assessment Module Mahesh M. Thapa 1,2, Sumit Pruthi 1,2, Felix S. Chew 2 ABSTRACT

More information

Analysis of factors affecting range of motion after Total Knee Arthroplasty

Analysis of factors affecting range of motion after Total Knee Arthroplasty IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861.Volume 14, Issue 9 Ver. II (Sep. 2015), PP 01-10 www.iosrjournals.org Analysis of factors affecting range of

More information

The arc of pelvic motion has been shown to be as great as 70 through sit to stand activities 1 DiGioia CORR 2006

The arc of pelvic motion has been shown to be as great as 70 through sit to stand activities 1 DiGioia CORR 2006 The arc of pelvic motion has been shown to be as great as 70 through sit to stand activities 1 DiGioia CORR 2006 Overview Every patient moves differently 1 and their total hip replacement should be optimised

More information

Guided growth with tension band plate or definitive epiphysiodesis for treatment of limb length discrepancy?

Guided growth with tension band plate or definitive epiphysiodesis for treatment of limb length discrepancy? Borbas et al. Journal of Orthopaedic Surgery and Research (2019) 14:99 https://doi.org/10.1186/s13018-019-1139-4 RESEARCH ARTICLE Guided growth with tension band plate or definitive epiphysiodesis for

More information

Management of knee flexion contractures in patients with Cerebral Palsy

Management of knee flexion contractures in patients with Cerebral Palsy Management of knee flexion contractures in patients with Cerebral Palsy Emmanouil Morakis Orthopaedic Consultant Royal Manchester Children s Hospital 1. Introduction 2. Natural history 3. Pathophysiology

More information

Hallux Valgus Deformity: Preoperative Radiologic Assessment

Hallux Valgus Deformity: Preoperative Radiologic Assessment 119 Pictorial Essay H............ - Hallux Valgus Deformity: Preoperative Radiologic Assessment David Karasick1 and Keith L. Wapner An estimated 40% of the American adult population experiences foot problems,

More information

New Radiographic Parameter Assessing Hindfoot Alignment in Stage II Adult Acquired Flatfoot Deformity

New Radiographic Parameter Assessing Hindfoot Alignment in Stage II Adult Acquired Flatfoot Deformity New Radiographic Parameter Assessing Hindfoot Alignment in Stage II Adult Acquired Flatfoot Deformity Emilie Williamson, BS; Jeremy Chan, MD; Jayme C Burket, PhD; Jonathan T Deland, MD; Scott Ellis, MD

More information

S. Robert Rozbruch, MD. Chief, Limb Lengthening & Complex Reconstruction Service Professor of Clinical Orthopedic Surgery

S. Robert Rozbruch, MD. Chief, Limb Lengthening & Complex Reconstruction Service Professor of Clinical Orthopedic Surgery S. Robert Rozbruch, MD Chief, Limb Lengthening & Complex Reconstruction Service Professor of Clinical Orthopedic Surgery Small Bone Innovations: consultant and royalties Smith and Nephew: consultant External

More information

The Use of Computed Tomography to Determine Femoral Component Size

The Use of Computed Tomography to Determine Femoral Component Size 49 The Use of Computed Tomography to Determine Femoral Component Size A Study of Cadaver Femora Murad Uslu, M.D., Baris Ozsar, M.D., Tuba Kendi, M.D., Simay Kara, M.D., Ibrahim Tekdemir, M.D., and O. Sahap

More information

KNEE. T. J. Shelton, A. J. Nedopil, S. M. Howell, M. L. Hull

KNEE. T. J. Shelton, A. J. Nedopil, S. M. Howell, M. L. Hull T. J. Shelton, A. J. Nedopil, S. M. Howell, M. L. Hull From Department of Orthopaedic Surgery, University of California, Davis, Sacramento, United States T. J. Shelton, MD, MS, Orthopaedic Surgeon, Department

More information

Hyperpronation of the foot causes many different

Hyperpronation of the foot causes many different IMMEDIATE CHANGES IN THE QUADRICEPS FEMORIS ANGLE AFTER INSERTION OF AN ORTHOTIC DEVICE D. Robert Kuhn, DC, a Terry R. Yochum, DC, b Anton R. Cherry, c and Sean S. Rodgers c ABSTRACT Objective: To measure

More information

... ON THE JOB. Holmblad Variations

... ON THE JOB. Holmblad Variations Holmblad Variations Dan L. Hobbs, M.S.R.S., R.T.(R)(CT)(MR), is an associate professor in the department of radiographic science at Idaho State University in Pocatello. In Chicago during the summer of

More information