1 Research, Educational and Other Activities at IMID Matúš Ranuša INSTITUTE OF MACHINE AND INDUSTRIAL DESIGN Faculty of Mechanical Engineering Brno University of Technology Brno, 4th April 2018
2 Contents Research Activities Introduction and Motivation Background Results Conclusion and Vision Educational Activities Events and IMID/BUT Activities 2/24
3 Introduction and motivation Total hip replacement Common and most successful surgeries 161 surgeries per population (OECD 2015) Limited longevity of implants (5-15 years) Surgeries/ 10 years 43,1% 44,9% 0,2% 0,7% 0,1% 3/24
4 Introduction and motivation Total hip replacement Common and most successful surgeries 161 surgeries per population (OECD 2015) Limited longevity of implants (5-15 years) Material Wear (mm 3 /year) UHMWPE - Kov 56 Cross linked UHMWPE - Kov 2,8 Kov - Kov 0,9 Keramika- Keramika 0,004 4/24
5 Introduction and motivation Metal - CoCr 9,8 % Polyethylene 72,1 % Ceramics 16 % Lubrication Friction Wear surgeries 5/24
6 Introduction and motivation Importance of wear analysis Lubrication Prediction of possible complications Friction Analysis of replacement failures Influence of position on replacement failures Wear Metrology Validation Application Usability 6/24
7 Background Reconstructed geometry Retrieved liner Metrology Validation Application Usability 7/24
8 Background Validation 3 new implants According ISO part 1 Gravimetric validation Wear 65 grams Diferences ± 4 miligrams Metrology Validation Application Usability 8/24
9 Results 16 retrieved implants Clinical data Scanning method Analysis of surface Martell s method 16 retrieved liners Metrology Validation Application Usability 9/24
10 Volumetric wear (mm 3 /year) Linear wear (mm/year) Results 0,4 0,3 0,2 0, retrieved liners Patient Metrology Validation Application Usability 10/24
11 Material properties Lubrication Friction Max load 3 kn 1Hz Flexion - extension ± 60 Rotation ± 10 Long term tests according ISO Wear Metrology Validation Application Usability 11/24
12 Material properties Lubrication Friction Wear Metrology Validation Application Usability 12/24
13 Friction coefficient Friction coefficient Roughness Ra Material properties 0,15 0,14 0,13 0,12 0,11 0,1 0,09 0,08 0,07 0,017 0,016 0,015 0,014 0,013 0,012 0,011 0,01 0, Cycles (x10 3 ) Cycles (x10 3 ) Lubrication Friction Wear Metrology Validation Application Usability 13/24
14 Chemical degradation Lubrication Friction Wear Metrology Validation Application Usability 14/24
15 Conclusions and Vision Conclusions Wear of liners depends mostly on: Inclination angle in pelvis Geometry of articulating surface Changes of surface structure Chemical degradation of surface Consequences: Particle loosening Delamination of surface Deformation of liner Revision surgeries Lubrication Friction Wear Visions Understanding of chemical changeses Modification of geometry Influence of particles in interaction with lubrication 15/24
16 Research identifiers CHOUDHURY, D.; RANUŠA, M.; FLEMING, R. A.; VRBKA, M.; KŘUPKA, I.; TEETER M. G.; GOSS, J.; ZOU, M. Mechanical Wear and Oxidative Degradation Analysis of Retrieved Ultra High Molecular Weight Polyethylene Acetabular Cups. Journal of the mechanical behavior of biomedical materials, 2018, roč. 79, č. 1, s ISSN: (IF 3,11 ; citation - 1 ) RANUŠA, M.; GALLO, J.; HOBZA, M.; VRBKA, M.; NEČAS, D.; HARTL, M. Opotřebení a drsnost artikulačního povrchu u extrahovaných polyetylénů jamky Bicon- Plus. Acta Chirurgie Orthopaedicae et Traumatologie Čechoslovaca, 2017, roč. 84, č. 3, s ISSN: (IF 0,56 ; citation - 2) RANUŠA, M.; GALLO, J.; VRBKA, M.; HOBZA, M.; PALOUŠEK, D.; KŘUPKA, I.; HARTL, M. Wear Analysis of Extracted Polyethylene Acetabular Cups Using a 3D Optical Scanner. TRIBOLOGY TRANSACTIONS, 2016, roč. 60, č. 3, s ISSN: (IF 1,69 ; citation - 3) RANUŠA, M.; ZEMAN, J.; GALLO, J.; VRBKA, M.; KŘUPKA, I.; HARTL,M. Experimental Determination of Effects of the Polyethylene Acetabular Positioning on the Run-in Phase of Wear and on the Surface Deformation. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B, APPLIED BIOMATERIALS. (In progress, April 2018) 16/24
17 Other activities Conferences Frejks days 2015 ( June, 25-26, Brno, Česká republika) HOBZA, M.; RANUSA, M. Valuation of Type and Wear of Retrieved Polyethylene Bicon Cups. NORDTRIB 2016 ( July, 14-17, Hämeenlinna, Fínsko) RANUSA, M.; VRBKA, M.; KŘUPKA, I.; HARTL, M. Development and Validation of an Optical Scanning Method for Volumetric Wear Analysis WTC 2017 ( September, 17 22, Beijing, China) RANUSA, M.; VRBKA, M.; GALLO, J.; KŘUPKA, I.; HARTL, M. Influence of Acetabular Cup Inclination on Wear of UHMWPE Liners. Cooperation Waterloo University, Canada, Ontario (prof. John B. Medley) internship, June, 6, 2016 August 27, 2016 Anglian Ruskin University, England, Chelmsford (Rajshree Hillstrom, PhD MBA) Arkansas University, USA, Arkansas (Dr. Dipankar Choudhury) 17/24
18 Educational activities ZKP Team Project ZIP Team Project ZTR Tribology 6KT Machine Design 0ZP Aventisc Pneumobil Racing Team Diploma theses supervision: Bc. Jakub Zeman (5r) Experimental Determination of Effects of the Polyethylene Acetabular Positioning on the Run-in Phase of Wear and on the Surface Deformation. Bc. Samuel Seidl (4r) Behavior of Polyethylene Particles in Contact Surfaces of Hip Joint Replacements 18/24
19 Pneumobil Mission: Learning by doing Mentoring Students working in a team Promotion of BUT Vision: Interfaculty cooperation Team structure Win competitions 19/24
20 20/24
21 21/24
22 Thank you.
Impingement in THA. Georgi I. Wassilew. Orthopaedic Department, Centrum für Muskuloskeletale Chirurgie Univ.-Prof. Dr. med. C.
Georgi I. Wassilew Orthopaedic Department, Centrum für Muskuloskeletale Chirurgie Univ.-Prof. Dr. med. C. Perka Charité - Universitätsmedizin Berlin Orthoload club, Berlin Reasons for revision in THA Reason
More informationThe information contained in this document is intended for healthcare professionals only.
The information contained in this document is intended for healthcare professionals only. Trident Hemispherical Acetabular Shell Trident PSL HA Acetabular Shell Featuring: The Trident Acetabular System
More information6.1 Hip Joint Simulators: State of the Art
Tribology 171 6.1 Hip Joint Simulators: State of the Art S. Affatato, W. Leardini and M. Zavalloni Abstract Wear and simulator testing are complicated tasks. Controlled wear testing should not be routinely
More informationDeveloping techniques for the dimensional assessment of true clinical wear in retrieved total joint replacements.
Developing techniques for the dimensional assessment of true clinical wear in retrieved total joint replacements. P. Bills*, L. Blunt*, G. Chakrabarty** *University of Huddersfield, Huddersfield, UK **West
More informationThe information contained in this document is intended for healthcare professionals only.
The information contained in this document is intended for healthcare professionals only. Trident Poly Acetabular System Trident PSL HA Acetabular Shell with X3 Poly insert Trident Hemispherical Acetabular
More informationOrthopedic Surgery (Adult Hip Service) (Seoul National University Hospital)
Orthopedic Surgery (Adult Hip Service) (Seoul National University Hospital) 1. Introduction Total hip replacement arthroplasty (THRA) using a metal-on-polyethylene articulation has become one of the most
More informationSurface evaluation of orthopedic hip implants marketed in Brazil
Surface evaluation of orthopedic hip implants marketed in Brazil M.M.Souza 1, R.M. Trommer 2, M.M.Maru 2, C.R.M.Roesler 3, W.S.Barros 1, M.S. Dutra 3 1 Dimensional Metrology Laboratory, Inmetro. Brazil;
More informationUHMWPE LONGEVITY: INFLUENCES OF THE ORTHOPAEDIC TRIAD
UHMWPE LONGEVITY: INFLUENCES OF THE ORTHOPAEDIC TRIAD AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS 66th Annual Meeting February 4-9, 1999 Anaheim, California COMMITTEE ON BIOMEDICAL ENGINEERING COMMITTEE ON
More informationWear Properties of UHMWPE in CHARITE Artificial Inter-vertebral Disc
Mechanics of Contact and Lubrication, MTM G230 Department of Mechanical & Industrial Enineering Northeastern University Spring 2006 Wear Properties of UHMWPE in CHARITE Artificial Inter-vertebral Disc
More informationMicroSeal Total Hip Acetabular System. Like Nothing Else
MicroSeal Total Hip Acetabular System Like Nothing Else Like Nothing Else Unique Patented Sealing and Locking Design The MicroSeal design features: Locking/Sealing mechanisms work together to minimize
More informationRetrieval Analysis of a Polycarbonate-Urethane Acetabular Cup: A Case Report
Journal of Long-Term Effects of Medical Implants, 18(1): 69 74 (2008) Retrieval Analysis of a Polycarbonate-Urethane Acetabular Cup: A Case Report W. Siebert, 1 S. Mai, 1 & S. Kurtz 2 1 Orthopädische Klinik
More informationCement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter
Design Philosophy Cementless Stems of 12/14 Taper Stem Length Neck shaft Angle STEM-N3 STEM-N4 STEM-N5 STEM-N6 STEM-N7 STEM-N8 STEM-N9 123 mm 125 mm 130 mm 135 mm 140 mm 145 mm 150 mm 132 Cement Polished
More informationInternational Journal of Engineering Research and Development e A Mathematical Model to Calculate Contact Stresses In Artificial Human Hip Joint
International Journal of Engineering Research and Development e-issn: 2278-067X, p-issn: 2278-800X, www.ijerd.com Volume 6, Issue 12 (May 2013), PP. 119-123 A Mathematical Model to Calculate Contact Stresses
More informationCeramTec Medical Products. BIOLOX DUO Ceramic Bipolar System. Bone-sparing joint reconstruction with a maximum range of motion
CeramTec Medical Products BIOLOX DUO Ceramic Bipolar System Bone-sparing joint reconstruction with a maximum range of motion 2 BIOLOX DUO Ceramic Bipolar System Less is more BIOLOX DUO is an alternative
More information6 th International Conference on Trends in Agricultural Engineering 7-9 September 2016, Prague, Czech Republic
MEASUREMENT OF PRESSURE DISTRIBUTION IN KNEE JOINT REPLACEMENT J. Volf 1, V. Novák 1, V. Ryzhenko 1, D. Novák 2 1 Faculty of Engineering, Czech University of Life Sciences Prague, Czech Republic 2 Faculty
More informationZimmer Longevity Highly Cross-linked Polyethylene. Clinical Value Dossier - APAC
Zimmer Longevity Highly Cross-linked Polyethylene Clinical Value Dossier - APAC Table of Contents 1 Executive Summary...................................................... 1 2 Burden of Illness........................................................
More informationMedical Products Division. BIOLOX DUO Ceramic Bipolar System. Bone-sparing joint reconstruction with a maximum range of motion
Medical Products Division BIOLOX DUO Ceramic Bipolar System Bone-sparing joint reconstruction with a maximum range of motion 2 BIOLOX DUO Keramisches Bipolarsystem BIOLOX DUO Ceramic Bipolar System Less
More informationWe are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors
We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists 4,000 116,000 120M Open access books available International authors and editors Downloads Our
More informationStability without compromise. Epsilon Durasul Constrained Insert
Stability without compromise Epsilon Durasul Constrained Insert History of Dislocation and Constrained Acetabular Inserts The Need for a Better Solution The Problem Dislocation is the second most common
More informationPrevention of dislocation after hip replacement in elderly patients. Piotr WOJCIECHOWSKI, Damian KUSZ, Mariusz NOWAK, Konrad KOPEĆ
Prevention of dislocation after hip replacement in elderly patients. Piotr WOJCIECHOWSKI, Damian KUSZ, Mariusz NOWAK, Konrad KOPEĆ Department of Orthopedics and Traumatology Medical University of Silesia
More informationDesign of a Hip Joint Simulator According to the ISO 14242
, July 6-8, 2011, London, U.K. Design of a Hip Joint Simulator According to the ISO 14242 Nikolaos I. Galanis, Member, IAENG and Dimitrios E. Manolakos Abstract Wear and simulator testing are complicated
More informationPrinciples of acetabular fixation in primary and revision hip arthroplasty Piotr Wojciechowski, Damian Kusz, Anna WAGNER
Principles of acetabular fixation in primary and revision hip arthroplasty Piotr Wojciechowski, Damian Kusz, Anna WAGNER Department of Orthopedics and Traumatology Medical University of Silesia Head of
More informationMerete BioBall The Innovative Hip Endoprosthesis Head Adapter System
Merete the «BioBall Company» You are better off with BioBall Your Indispensable Assistant in Hip Arthroplasties. Merete BioBall The Innovative Hip Endoprosthesis Head Adapter System 2 BioBall System Merete
More informationEffect of Femoral Head Size to Contact Stress at Pure Titanium Femoral Ball Head Outer Surface of Hip Joint Implant
Effect of Femoral Head Size to Contact Stress at Pure Titanium Femoral Ball Head Outer Surface of Hip Joint Implant Agung Setyo Darmawan, Waluyo Adi Siswanto, Haryanti Samekto Faculty of Mechanical and
More informationPyroCarbon Implants Durability + Biocompatibility
PyroCarbon Implants Durability + Biocompatibility What is PyroCarbon? PyroCarbon is a specific form of carbon that has been tailored for durability and biocompatibility. PyroCarbon exhibits favorable wear
More informationSystematic Review of Clinical Outcome using Titanium Fiber Mesh Porous Ingrowth Surfaces
Systematic Review of Clinical Outcome using Titanium Fiber Mesh Porous Ingrowth Surfaces Timothy L. Tan, BS 1, Brenna C. Moeljadi, BS 2, Edward Ebramzadeh, PhD 3, Patricia Campbell, PhD 3, Sophia Nicole
More informationActive Articulation E1
Active Articulation E1 Dual Mobility Hip System Design Rationale Knees Hips Extremities Cement and Accessories PMI Trauma Technology Active Articulation E1 Dual Mobility Hip System Dual Mobility: Not a
More informationA NEW APPROACH TO BEARING SURFACES FOR TOTAL HIP ARTHROPLASTY
A NEW APPROACH TO BEARING SURFACES FOR TOTAL HIP ARTHROPLASTY by Timothy McTighe, Exec. Dir., JISRF, Chagrin Falls, Ohio Ying Ko, Ph.D., Cincinnati, Ohio Russell B. Bennett, Ph.D., Cincinnati, Ohio James
More informationAesculap Plasmafit. Cementless Acetabular Cup System. Aesculap Orthopaedics
Aesculap Plasmafit Cementless Acetabular Cup System Aesculap Orthopaedics Aesculap Plasmafit Cementless Acetabular Cup System 2 Content Plasmafit Concept 4 Plasmafit System 6 Plasmafit Surface 8 Plasmafit
More informationEnhancing stability and increasing range of motion. Metasul LDH Large Diameter Head
Enhancing stability and increasing range of motion Metasul LDH Large Diameter Head The Metasul large diameter head technology is the result of in-depth research, development and clinical experience that
More informationBIOTRIBOLOGICAL AND MECHANICAL ANALYSIS OF TOTAL HIP ARTHROPLASTIY FAILURE: How to break the code
BIOTRIBOLOGICAL AND MECHANICAL ANALYSIS OF TOTAL HIP ARTHROPLASTIY FAILURE: How to break the code Patrick Chaboche, MD patrick.chaboche@wanadoo.fr Former Head of Department of Orthopaedic Surgery. Centre
More informationCeramic Femoral Heads and Acetabular Cup Liners
Important Information: Please read prior to use in a clinical setting. The Surgeon should be familiar with the operative technique. Caution: Federal (U.S.A) law restricts this device to sale by or on the
More informationProduct Information. *smith&nephew POLARCUP Dual Mobility System
APPLYING SCIENCE TO MOBILITY Combined with VERILAST Technology for unmatched performance Product Information *smith&nephew POLARCUP Dual Mobility System APPLYING SCIENCE TO MOBILITY Combined with VERILAST
More information(c) B. Ravi, IIT Bombay 1
Collaborative Engineering Evaluation, Testing TKP Safety, TKP System Mechanism FEA Physical testing Fatigue Wear What How Evaluate Testing Judgement Criteria's Testing Conditions Parameters Measured OrthoCAD
More informationNEW DESIGN OF PURE TITANIUM METAL ON METAL TOTAL HIP REPLACEMENT WITH ION IMPLANTED WEAR RESISTANCE SURFACE
NEW DESIGN OF PURE TITANIUM METAL ON METAL TOTAL HIP REPLACEMENT WITH ION IMPLANTED WEAR RESISTANCE SURFACE WALUYO AD1 SISWANTO GERAN PENYELIDIKAN SCIENCEFUND NO. VOT. SO15 UNIVERSITI TUN HUSSEIN ONN MALAYSIA
More informationCatherine Bladen, John Fisher, Eileen Ingham, Joanne Tipper University of Leeds, UK
Institute of Medical & Biological Engineering Reduced inflammatory potential of Antioxidant Ultra High Molecular Weight Polyethylene containing Vitamin E May Lead to Improved Longevity in Total Joint Replacement
More informationCase report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?
Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis? Diagnosis: Ceramic head fracture In the 1970 s, Boutin implemented ceramic in modern total hip arthroplasty (THA).
More information*smith&nephew POLARCUP Dual Mobility System. Product Information
Product Information *smith&nephew POLARCUP Dual Mobility System Dual Mobility 30 Years of Clinical Experience Concept combining an extended ROM, a low rate of dislocation and unexpectedly limited wear.
More informationTotal Hip Arthroplasty Using Metal Head on a Highly Cross-linked Polyethylene Liner
ORIGINAL ARTICLE Hip Pelvis 27(4): 216-222, 2015 http://dx.doi.org/10.5371/hp.2015.27.4.216 Print ISSN 2287-3260 Online ISSN 2287-3279 Total Hip Arthroplasty Using Metal Head on a Highly Cross-linked Polyethylene
More informationClinical Study Comparison of Conventional Polyethylene Wear and Signs of Cup Failure in Two Similar Total Hip Designs
Advances in Orthopedics Volume 2013, Article ID 710621, 7 pages http://dx.doi.org/10.1155/2013/710621 Clinical Study Comparison of Conventional Polyethylene Wear and Signs of Cup Failure in Two Similar
More informationReduction of In Vivo Oxidation induced by Lipid Absorption by Phospholipid Polymer Grafting on Orthopedic Bearings
Reduction of In Vivo Oxidation induced by Lipid Absorption by Phospholipid Polymer Grafting on Orthopedic Bearings Masayuki Kyomoto, Ph.D. 1,2, Toru Moro, M.D., Ph.D. 1, Shihori Yamane, MSc 1,2, Kenichi
More informationDamage of an Oxinium femoral head and polyethylene liner following routine total hip replacement
CASE REPORT Damage of an Oxinium femoral head and polyethylene liner following routine total hip replacement R. W. McCalden, K. D. Charron, R. D. Davidson, M. G. Teeter, D. W. Holdsworth From London Health
More informationCERAMIC-ON-METAL. References: Cat No: version 2
CERAMIC-ON-METAL References: 1. Beaule, P. E., et al. Jumbo femoral head for the treatment of recurrent dislocation following total hip replacement. J.Bone Joint Surg (2002). 84-A: 256-63. 2. Jolles, B.
More informationOptimum implant geometry
Design Rationale Optimum implant geometry Extending the proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available
More informationRM Philosophy Innovation based on clinical evidence.
RM Philosophy Innovation based on clinical evidence RM Philosophy Innovation based on clinical evidence Design 1973 RM Classic Cup First uncoated RM Classic Cup out of Polyacetal was inserted by E. Morscher
More information39 year old, 260 lb. park ranger. TKA in situ: 4 Years. First reported Metal-backed, non-modular PCA knee. 16% incidence. Modular metalbacked
Designer (Royalty income) - DePuy A Johnson & Johnson Company Consultant on Knee Products for Smith & Nephew Orthopaedics General Research Funding Inova Health System and the U.S. Army Medical Research
More informationWear 268 (2010) Contents lists available at ScienceDirect. Wear. journal homepage:
Wear 268 (2010) 617 621 Contents lists available at ScienceDirect Wear journal homepage: www.elsevier.com/locate/wear Wear comparison between a dual mobility total hip prosthesis and a typical modular
More informationImplants for surgery Partial and total hip joint prostheses. Part 12: Deformation test method for acetabular shells
INTERNATIONAL STANDARD ISO 7206-12 First edition 2016-10-01 Implants for surgery Partial and total hip joint prostheses Part 12: Deformation test method for acetabular shells Implants chirurgicaux Prothèses
More information[ICESTM-2018] ISSN Impact Factor
GLOBAL JOURNAL OF ENGINEERING SCIENCE AND RESEARCHES MODELING AND FINITE ELEMENT ANALYSIS OF KNEE JOINT PROSTHESIS U.D.S.Prathap varma *1,S.Rajesh 2, B.Suresh Kumar 3 & P.Rama Murthy Raju 4 *1 M.TechScholar,
More informationZimmer TM. Continuum Acetabular System. Bringing together proven technologies.
Zimmer TM Continuum Acetabular System Bringing together proven technologies. The power to meet individual patient needs. Zimmer Continuum Acetabular System provides highly flexible solutions for orthopaedic
More informationDUAL MOBILITY CUP, CEMENTED OR CEMENTLESS
HIP Documentation DUAL MOBILITY CUP, CEMENTED OR CEMENTLESS >>DUAL MOBILITY ACETABULAR CUPS Dual mobility acetabular cup P r Gilles Bousquet invented the concept of dual mobility more than thirty years
More informationADDITIVE MANUFACTURING AND ANALYSIS OF TIBIAL INSERT IN TOTAL KNEE REPLACEMENT IMPLANT
ADDITIVE MANUFACTURING AND ANALYSIS OF TIBIAL INSERT IN TOTAL KNEE REPLACEMENT IMPLANT Swathi Harish 1, V R Devadath 2 1 M.Tech Scholar, Department of Mechanical Engineering, PESCE, Mandya, Karnataka,
More informationOptimum implant geometry
Design Rationale Optimum implant geometry Extending proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available
More information*smith&nephew EP-FIT PLUS Cementless Press-Fit Cup System. Product Information
Product Information *smith&nephew EP-FIT PLUS Cementless Press-Fit Cup System EP-FIT PLUS Press-Fit Acetabular Cup System A new generation in press-fit cup technology Proven anchoring concept in combination
More informationARTICLE IN PRESS. Surface Oxidized Zirconium Total Hip Arthroplasty Head Damage Due to Closed Reduction. Effects on Polyethylene Wear
The Journal of Arthroplasty Vol. 00 No. 0 2008 Surface Oxidized Zirconium Total Hip Arthroplasty Head Damage Due to Closed Reduction Effects on Polyethylene Wear William L. Jaffe, MD,* Eric J. Strauss,
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 7206-12 First edition 2016-10-01 Implants for surgery Partial and total hip joint prostheses Part 12: Deformation test method for acetabular shells Implants chirurgicaux Prothèses
More informationThird-Body Wear Behavior of Orthopaedic Biopolymers
Proceedings of the World Congress on Mechanical, Chemical, and Material Engineering (MCM 2015) Barcelona, Spain July 20-21, 2015 Paper No. 363 Third-Body Wear Behavior of Orthopaedic Biopolymers Binnur
More informationThe Spatial Location of Impingement in Total Hip Arthroplasty
The Journal of Arthroplasty Vol. 15 No. 3 2000 The Spatial Location of Impingement in Total Hip Arthroplasty Motoi Yamaguchi, MD, PhD,* Toshihiro Akisue, MD, PhD,* Thomas W. Bauer, MD, PhD,* and Yasushi
More informationOPTIMIZATION OF SKELETAL HIP IMPLANT CROSS-SECTIONS
OPTIMIZATION OF SKELETAL HIP IMPLANT CROSS-SECTIONS Sudesh Sivarasu, Pearline Beulah, Lazar Mathew School of Bio Sciences & Technology, VIT University, Vellore sudeshsivarasu@gmail.com Abstract: Aseptic
More informationFinite Element Study of Acetabular Cup Contact Region for Total Hip Replacement (THR)
Journal of Mechanical Engineering Vol SI (), 7-8, 07 Finite Element Study of Acetabular Cup Contact Region for Total Hip Replacement (THR) Muhammad Faris Abd Manap Solehuddin Shuib Faculty of Mechanical
More informationRichard Underwood, Ph.D., CEng, P.E.
Managing Engineer Biomedical Engineering 3440 Market Street, Suite 600 Philadelphia, PA 19104 (215) 594-8875 tel runderwood@exponent.com Professional Profile Dr. Underwood is a Chartered Engineer and Member
More informationI want that next-generation knee
I want that next-generation knee High flex Potentially longer-lasting More normal feeling Gender-optimized Less-invasive procedure Advanced design technology The last ten years have yielded an explosion
More informationUnderstanding Hip Implant Options
Understanding Hip Implant Options Cup (Socket) Bearing (Liner) Head Stem (Femur) Modern Hip Implants (Ball) Metal Femoral Head on Marathon Cross-linked Polyethylene Liner Proven materials Polyethylene
More informationEffect of alumina femoral heads on polyethylene wear in cemented total hip arthroplasty
Effect of alumina femoral heads on polyethylene wear in cemented total hip arthroplasty OLD VERSUS CURRENT ALUMINA K. Tanaka, J. Tamura, K. Kawanabe, M. Shimizu, T. Nakamura From Kyoto University, Japan
More informationFIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY
FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY Fixation First FIXATION FIRST 1958 Charnley Hip Over 1,000,000 implanted 1 96.2 percent survivorship at 32 years
More informationManza Cup HA SURGICAL TECHNIQUE.
1 PRE-OPERATIVE PLANNING. Preoperative assessment of the appropriate size and position of the acetabular component will provide intraoperative guidance for acetabular reaming. To determine the acetabluar
More informationGENESIS II/ LEGION Total Knee System
GENESIS II/ LEGION Total Knee System The GENESIS II/LEGION knee with the VERILAST technology The knee tested to simulate 30 years of wear performance DISCLAIMER: Always speak to your doctor about the options
More informationSpecializing in Mechanical Testing for Medical Devices. Office:
Specializing in Mechanical Testing for Medical Devices Office: 260.489.1444 Email: sales@jtlamerica.com www.jtlamerica.com Spine Spinal implant test standards can t keep up with the rapid pace of device
More informationCURRICULUM VITAE CHRISTINE STEUBBEN HEIM Ward Drive Chesterland, OH Telephone:
EDUCATION CURRICULUM VITAE CHRISTINE STEUBBEN HEIM 12655 Ward Drive Chesterland, OH 44026 Telephone: +440 729 9274 B.Sc. (Biomedical Engineering) Case Western Reserve University, Cleveland, Ohio (1992)
More informationHip dislocation after total hip arthroplasty can be classified
Case Report Late Anterior Hip Dislocation after Metasul Metal-on-Metal Total Hip Arthroplasty for 13 Years: A Case Report Larbpaiboonpong V email : virojlarb@gmail.com Viroj Larbpaiboonpong 1 Suthorn Bavonratanavech
More informationLong-term Wear Evaluation of an Artificial Medial Meniscus Implant
Long-term Wear Evaluation of an Artificial Medial Meniscus Implant Jonathan J. Elsner, PhD, Maoz Shemesh, MSc, Adaya Shefy-Peleg, MSc, Eyal Zylberberg, BSc, Eran Linder-Ganz, PhD. Active Implants, Netanya,
More informationFeaturing. Technology. Product Rationale
Featuring Technology Product Rationale 2 Optimum implant geometry Extending proven TRI-LOCK heritage The original TRI-LOCK Stem was introduced in 1981. This implant was the first proximally coated tapered-wedge
More informationTrident Ceramic Acetabular System Technical Monograph
Trident Ceramic Acetabular System Technical Monograph Introduction Clinical research and laboratory testing have demonstrated the benefits of ceramic-on-ceramic bearings in THA. Among these benefits are
More informationProgeny Hip Stem. Surgical Protocol and Product Specifications
Progeny Hip Stem Surgical Protocol and Product Specifications Progeny Hip Stem Introduction With emphasis on maximum stability and ease of use, the StelKast ProgenyTM Hip System provides the surgeon with
More informationCementless femoral stem type SF
Cementless femoral stem type SF Cementless Femoral Hip Joint Components ARTHROPLASTY Implant Description Surgical Technique Instrumentation Set Catalogue Preface The cementless stem of a total hip joint
More informationTrusted technology. Trusted performance. Supporting healthcare professionals
Trusted technology. Trusted performance. Supporting healthcare professionals Trusted technology. Trusted performance. The POLAR3 Total Hip Solution, powered by Smith & Nephew s proprietary VERILAST Technology,
More informationMARATHON Cross-Linked Polyethylene
MARATHON Cross-Linked Polyethylene Fixation First... 1 Wear Reduction... 2 Oxidative Stability... 3 Mechanical Integrity... 4 Proven Technology...5-6 References... 7 Fixation First FIXATION FIRST Prodigy
More informationBone Bangalore
Dr Suresh Annamalai MBBS, MRCS(Edn), FRCS( Tr & Orth)(Edn), FEBOT(European Board), Young Hip and Knee Fellowship(Harrogate, UK) Consultant Arthroplasty and Arthroscopic Surgeon Manipal Hospital, Whitefield,
More informationPoor mid-term results of total hip arthroplasty with use of a Hylamer liner
Acta Orthop. Belg., 2008, 74, 337-342 ORIGINAL STUDY Poor mid-term results of total hip arthroplasty with use of a Hylamer liner Adrian SKWARA, Simone STRACKE, Carsten O. TIBESKU, Susanne FUCHS-WINKELMANN
More informationExamination of Porous-Coated Patellar Components and Analysis of the Reasons for Their Retrieval
Examination of Porous-Coated Patellar Components and Analysis of the Reasons for Their Retrieval J. P. Collier,* M. B. Mayor,+ V. A. Surprenant,* H. P. Surprenant,* and R.E. Jensen* *Dartmouth Biomedical
More informationDepartment of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Maidashi, Higashi-ku, Fukuoka , Japan
Wear Resistant Performance of Highly Cross-Linked and Annealed Ultra-High Molecular Weight Polyethylene against Ceramic Heads in Total Hip Arthroplasty Taishi Sato, Yasuharu Nakashima, Mio Akiyama, Takuaki
More informationWhat Are Hip and Knee Replacement Implants Made Of?
What Are Hip and Knee Replacement Implants Made Of? Hip and knee replacement surgery involve replacing the worn-out bone and cartilage lining your hip or knee joint with new implants that are composed
More informationExeter. Designed for Anatomic Restoration. Clinical Evidence Education
Exeter Designed for Anatomic Restoration Clinical Evidence Education Anatomic Restoration Exeter re-creating biomechanics In hip replacement, the smallest adjustment can make a big difference. Stryker
More informationCAUTION: Ceramic liners are not approved for use in the United States.
Total Hip Prostheses, Self-Centering Hip Prostheses and Hemi-Hip Prostheses IMPORTANT: This essential product information sheet does not include all of the information necessary for selection and use of
More informationSURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS
SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS INTRODUCTION The Summit Tapered Hip System s comprehensive set of implants and instruments
More informationHipNav: Pre-operative Planning and Intra-operative Navigational Guidance for Acetabular Implant Placement in Total Hip Replacement Surgery
Proc. of the Computer Assisted Orthopaedic Surgery Symposium, Bern, Switzerland, November, 1995 HipNav: Pre-operative Planning and Intra-operative Navigational Guidance for Acetabular Implant Placement
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 EMPIRICAL TESTING CORP. 4628 Northpark Drive Colorado Springs, CO 80918 Dawn Lissy Phone: 719 264 9937 dlissy@empiricaltesting.com MECHANICAL Valid To: January
More informationDesigned for life. Implant technology with unmatched wear performance
Designed for life Implant technology with unmatched wear performance Designed for life Wear performance combined with a multitude of options so you can find the right combination to restore the joints
More informationThis is a repository copy of PEEK-OPTIMA as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study.
This is a repository copy of PEEK-OPTIMA as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study. White Rose Research Online URL for this paper: http://eprints.whiterose.ac.uk/104453/
More informationFINITE ELEMENT ANALYSIS OF KNEE IMPLANT AND PROTOTYPE FABRICATION USING RPT PROCESS
International Journal of Mechanical Engineering and Technology (IJMET) Volume 8, Issue 12, December 2017, pp. 197 205, Article ID: IJMET_08_12_020 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=8&itype=12
More informationInvestigation of mechanisms leading to early aseptic. loosening of hip prostheses
Investigation of mechanisms leading to early aseptic loosening of hip prostheses A retrieval study of 27 failed cases of cemented Spectron EF stem in combination with Reflection acetabular cup Ruiting
More informationCOMMERCIAL LEAFLET. Inventor of dual mobility. in Novae. range
COMMERCIAL LEAFLET Inventor of dual mobility Novae range in 1975 Novae range Novae concept SUNFIT TH The dual mobility concept was invented in 1975 by Professor Gilles BOUSQUET and the engineer André RAMBERT,
More informationPeggers Super Summaries: THR and Revision Concepts
Total Hip replacement: ARTICUALTIONS Ceramic on polyethylene Ceramic on ceramic for young Metal on metal (resurfacing) Metal (cobalt chrome) on polyethylene WEAR Wear debris similar to bacteria o < 10
More informationR3think your options. For US distribution only.
R3think your options For US distribution only. R3think acetabular surgery It is widely accepted that total hip replacement surgery is one of the most successful procedures done today. Typically more thought
More informationCHAPTER 1 INTRODUCTION
1 CHAPTER 1 INTRODUCTION 1.1 Development history of total hip replacement Owing to the crippling nature of arthritis, the medical profession has been trying for well over a century to successfully treat
More informationCemented femoral stem - type CSC
Cemented femoral stem - type CSC Cemented Femoral Hip Joint Components ARTHROPLASTY Implant Description Preface The cemented femoral stem type CSC with centralizer was designed using the latest knowledge
More informationVolumetric Wear Assessment and Characterization of Striated Pattern of Retrieved. UHMWPE Tibial Inserts
Volumetric Wear Assessment and Characterization of Striated Pattern of Retrieved UHMWPE Tibial Inserts BY ELMIRA MOSLEMI RAD M.S., Shahid Bahonar University of Kerman, Iran, 2009 THESIS Submitted as a
More informationTrinity. Advanced Bearing Acetabular System Surgical technique
Advanced Bearing Acetabular System Surgical technique Contents Operative summary Introduction Pre-operative planning Acetabular preparation Acetabular reaming Reamer guide Acetabular shell trials Acetabular
More informationReaching new heights. Comprehensive. Efficient. Simple.
Reaching new heights Comprehensive. Efficient. Simple. Various acetabular cup choices Compatible with the different head and liner options including VERILAST Technology Reach for proven OR efficient Instrumentation
More informationIn Vivo Dissociation Of A Dual Articulation Bearing In Revision THA -Case Report-
Chagrin Falls, Ohio, USA In Vivo Dissociation Of A Dual Articulation Bearing In Revision THA -Case Report- Edward J. McPherson, MD, FACS*, Sherif Sherif, MD* Key Words: Dual Articulation, Dual Mobility,
More information