Revo MRI Pacing System

Size: px
Start display at page:

Download "Revo MRI Pacing System"

Transcription

1 Brief Statement The Revo MRI SureScan pacing system is MR Conditional and as such is designed to allow patients to undergo MRI under the specified conditions for use. Indications: The Revo MRI SureScan Model RVDR01 IPG is indicated for use as a system consisting of a Medtronic Revo MRI SureScan IPG implanted with two CapSureFix MRI SureScan 5086MRI leads. A complete system is required for use in the MRI environment. The Revo MRI SureScan Model RVDR01 IPG is indicated for the following: Rate adaptive pacing in patients who may benefit from increased pacing rates concurrent with increases in activity Accepted patient conditions warranting chronic cardiac pacing include: Symptomatic paroxysmal or permanent second- or thirddegree AV block Symptomatic bilateral bundle branch block Symptomatic paroxysmal or transient sinus node dysfunctions with or without associated AV conduction disorders Bradycardia-tachycardia syndrome to prevent symptomatic bradycardia or some forms of symptomatic tachyarrhythmias The device is also indicated for dual chamber and atrial tracking modes in patients who may benefit from maintenance of AV synchrony. Dual chamber modes are specifically indicated for treatment of conduction disorders that require restoration of both rate and AV synchrony, which include: Various degrees of AV block to maintain the atrial contribution to cardiac output VVI intolerance (for example, pacemaker syndrome) in the presence of persistent sinus rhythm Antitachycardia pacing (ATP) is indicated for termination of atrial tachyarrhythmias in bradycardia patients with one or more of the above pacing indications. Atrial rhythm management features such as Atrial Rate Stabilization (ARS), Atrial Preference Pacing (APP), and Post Mode Switch Overdrive Pacing (PMOP) are indicated for the suppression of atrial tachyarrhythmias in bradycardia patients with atrial septal lead placement and one or more of the above pacing indications. Contraindications: The device is contraindicated for: Implantation with unipolar pacing leads Concomitant implantation with another bradycardia device Concomitant implantation with an implantable cardioverter defibrillator Medtronic, Inc. 710 Medtronic Parkway Minneapolis, MN USA Tel: (763) Fax: (763) Medtronic USA, Inc. Toll-free: 1 (800) (24-hour technical support for physicians and medical professionals) There are no known contraindications for the use of pacing as a therapeutic modality to control heart rate. The patient s age and medical condition, however, may dictate the particular pacing system, mode of operation, and implantation procedure used by the physician. Rate responsive modes may be contraindicated in those patients who cannot tolerate pacing rates above the programmed Lower Rate Dual chamber sequential pacing is contraindicated in patients with chronic or persistent supraventricular tachycardias, including atrial fibrillation or flutter Single chamber atrial pacing is contraindicated in patients with an AV conduction disturbance ATP therapy is contraindicated in patients with an accessory antegrade pathway Warnings and Precautions: Changes in patient s disease and/or medications may alter the efficacy of the device s programmed parameters. Patients should avoid sources of magnetic and electromagnetic radiation to avoid possible underdetection, inappropriate sensing and/or therapy delivery, tissue damage, induction of an arrhythmia, device electrical reset, or device damage. Do not place transthoracic defibrillation paddles directly over the device. Use of the device should not change the application of established anticoagulation protocols. Patients and their implanted systems must be screened to meet the MRI Conditions of Use. Do not scan patients who do not have a complete Revo MRI SureScan pacing system consisting of a SureScan device and two SureScan leads; patients who have previously implanted devices, or broken or intermittent leads; or patients who have a lead impedance value of < 200 Ω or > 1,500 Ω. Do not scan patients with a SureScan pacing system implanted in sites other than the left and right pectoral region; or patients positioned such that the isocenter (center of MRI bore) is inferior to C1 vertebra and superior to the T12 vertebra. Potential Complications: Potential complications include, but are not limited to, rejection phenomena, erosion through the skin, muscle or nerve stimulation, oversensing, failure to detect and/or terminate arrhythmia episodes, acceleration of tachycardia, and surgical complications such as hematoma, infection, inflammation, and thrombosis. Potential lead complications include, but are not limited to, valve damage, fibrillation, thrombosis, thrombotic and air embolism, cardiac perforation, heart wall rupture, cardiac tamponade, pericardial rub, infection, myocardial irritability, and pneumothorax. Other potential complications related to the lead may include lead dislodgement, lead conductor fracture, insulation failure, threshold elevation, or exit block. The SureScan system has been designed to minimize potential complications in the MRI environment. Potential MRI complications include, but are not limited to, lead electrode and/or device heating which may cause tissue damage, impact the pacing system functionality such as failure to detect/treat irregular heartbeats, or potential for VT/VF induction. See the device manuals before performing an MRI Scan for detailed information regarding the implant procedure, indications, MRI conditions of use, contraindications, warnings, precautions, and potential complications/adverse events. For further information, call Medtronic at 1 (800) and/or consult Medtronic s website at Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. UC b EN Medtronic, Inc Minneapolis, MN. All Rights Reserved. Printed in USA. 07/2012 Revo MRI Pacing System ENGINEERED WITH SURESCAN TECHNOLOGY FDA-approved for MRI use The first pacing system to break the image barrier The Revo MRI SureScan pacing system is MR Conditional designed to allow patients to undergo MRI under the specified conditions for use. A complete system, consisting of a Medtronic Revo MRI SureScan IPG implanted with two CapSureFix MRI SureScan leads is required for use in the MRI environment.

2 The First and Only Pacing System FDA-Approved for MRI Use MRI Development Program Initiated research Began technology work with international experts Commenced formal discussions with regulatory bodies (TUV, FDA ) Completed first system modifications; started extensive test program Finalized device modifications; defined human clinical trial Clinical trial completed 2011 Commenced worldwide 1st-generation Revo MRI SureScan pacing system clinical trial Revo MRI pacing system receives FDA approval Specifically engineered for MRI safety, with reliable lead technology and a proven pacemaker platform this is state-of-the-art pacing. Now your patients get proven cardiac care with MRI access.

3 Meeting the Need for MRI Pacemaker Implants in an Aging Population The number of pacemakers currently implanted in the United States is approximately 1.5 million 1,2 Average Age of Pacemaker Patient 13% Age % Age 65+ The Pacemaker Population Elderly patients are the primary users of MRI: individuals over age 65 are twice as likely to need an MRI compared to younger recipients. 3

4 Part of Comprehensive Patient Care Now, for the first time, you can implant a state-of-the-art pacing system to provide proven cardiac care AND MRI access when your patients need it Number of Comorbidities in Pacemaker Patients Medical and Surgical Specialties Rely on MRI for Diagnosis. Your choice can affect their decisions and diagnostic capabilities Cardiologist DEVICE CHOICE Electrophysiologist 15% 0 comorbidities 27% 3 or more comorbidities 30% 1 comorbidity 28% 2 comorbidities 85% 1 1 or more comorbidities Ophthalmology Otolaryngology Cardiothoracic Surgery Surgical Oncology Nephrology Gynecologic Oncology Urology Neurosurgery Neurology Oncology Radiation Oncology Interventional Radiology Gastrointestinal Surgery Orthopedic Surgery Comprehensive Care Given that 85% of all pacemaker patients have one or more comorbidities, facilitating comprehensive multi-specialty care is important in today s environment Rheumatology Vascular Surgery

5 Prevalence of Common Comorbidities in the Pacemaker Patient Population MRI Is the Gold Standard Diagnostic Tool for Neurologists, Oncologists, and Orthopedic Surgeons, Whose Patients Are Often over 65 Years of Age. 7 MRI is unmatched in its ability to accurately visualize soft tissue The Prevalence of Common Comorbidities Increases Rapidly Over Age It is estimated that 50 to 75% of pacemaker patients will have a medical need for an MRI over the lifetime of their device 1 18% Prevalence in US Population 16% 14% 12% 10% 8% 6% 4% Stroke Prostate Cancer Osteoarthritis Colorectal Cancer The Most Common Reasons for MRI Referral Are Musculoskeletal and Neurological Symptoms. 8 Medicare records show that in patients > 65 years of age with an implanted pacemaker: 34% have spine and intervertebral disc disease 9 36% have chronic pain of wrist, foot, ankle, or elbow 9 2% 14% suffer from injury or trauma to the spine, knee, or shoulder 9 0% 30s 40s 50s 60s 70s Age by Decade Prevalence of Coexisting Conditions

6 Hazards and Risks of MRI with Current Pacing Systems Since 2008, the safety and risk concerns of MRIs in cardiac device patients have been documented in 17 studies MRI can put pacemaker patients at risk for any of the following 25 : Potential Hazard Lead Heating The conductive pacing lead acts as an antenna, picking up radiofrequency energy. A portion of this energy is dissipated as heat in the cardiac tissue nears the tip electrode. Unintended Cardiac Stimulation The gradient and radiofrequency fields will induce voltages in pacemaker leads that will be applied to the pacing lead electrodes. If these voltage pulses are large enough, they may directly stimulate the heart. Device Interactions The gradient, radiofrequency, and static fields may adversely affect the electrical operation of the pacemaker system if its operation is not protected from the effects of those fields. Device Field Impact Static Gradient RF Tissue damage may affect pacing therapy. May lead to a single or intermittent stimulation, or sustained tachycardia. Pacemaker malfunction or failure may affect pacing therapy. Hazards and Risks of MRI MR Conditional Risk Information A complete Revo MRI SureScan pacing system including a Revo MRI SureScan IPG and two CapSureFix MRI SureScan leads is required for use in the MRI environment Any other pacing system combination may result in a hazard to the patient during an MRI scan When programmed to On, the MRI SureScan feature allows the patient to be safely scanned while the device continues to provide appropriate pacing Refer to the Revo MRI Pacing System Conditions for Use located in the device manuals prior to scanning a patient. Consult Medtronic s website at or call Medtronic at 1 (800)

7 Specifically Engineered for MRI Safety Device Design Solutions Input circuits optimized Circuit design immune to interference SureScan pacing mode Asynchronous pacing High pacing outputs The Revo MRI SureScan pacing system has completed clinical evaluation, regulatory review, and FDA approval and is safe for use when used according to the MRI conditions for use as defined in the SureScan manual The implanted system must consist solely of a Medtronic Revo MRI SureScan Model RVDR01 device and two CapSureFix MRI SureScan Model 5086MRI leads Revo MRI SureScan Pacemaker A Pacemaker Engineered with Multiple Safety Features Device verification appears on pacemaker programmer screen Automatic testing ensures only appropriate battery and impedance data are collected during MRI Dedicated programming mode provides additional security/backup for Power On Reset (POR) Hall sensor immune to strong magnetic fields Key Product Features Easily Identifiable, Radiopaque Icon Confirms SureScan Device Implant Revo MRI Pacing System Size 12.7 cc Weight 21.5 g

8 Lead Heating Design Solution Lead inner conductor coil design mitigates lead heating 4 filar to 2 filar increases inductance and reduces heating Materials identical to 5076* Model 5086MRI lead flex testing Connector/body Lead body Model 5086MRI clinical implant experience starting February 2007 (928 leads implanted) Easily Identifiable, Radiopaque Icon Confirms SureScan Device Implant CapSureFix MRI Model 5086 Polarity Shape Fixation Inner/Outer Insulator Body Recommended Introducer Size Tip-to-Ring Spacing Standard Lengths Bipolar Straight Screw-in Silicone 7 Fr 8 Fr (without guide wire) 10 mm 45 cm, 52 cm, 58 cm * Exception of MRI Marker band and electrode coating Lead Heating Model 5076 versus Model 5086MRI CapSureFix MRI SureScan Lead Model 5086 A Lead Designed for MRI Use The state-of-the-art 5086 leads are specifically designed and engineered for safety within an MRI environment The 5086 lead is based on the CapSureFix family of leads, which have been implanted in more than 1 million patients worldwide that s 2.5 million leads, with 99.5% reliability Percent of Maximum Temperature Model Model Lead Path the x-axis represents 50 anatomically relevant leads paths the results demonstrate significant variability in lead tip heating as a function of the lead path overall the 5086MRI lead heats approximately 3 times less than the 5076 for most lead paths

9 Preclinical Research Demonstrates the Safety of Revo MRI Pacing System 7 Testing Summary Extensive preclinical evaluation was based on clinically relevant as well as worst-case scan conditions, using in vitro (bench) testing, in vivo (animal) testing, and computer simulations (modeling). MRI-Induced Lead Heating Simulations in Human Body Models Using Different Lead Combinations MRI-Induced Unintended Cardiac Stimulation (UCS) Analysis combined a prediction for the induced voltage pulse widths and amplitudes and an in vivo canine study to evaluate the stimulation threshold to these pulses The risk of reaching the gradient stimulation range is 1/1,000,000 which remains outside the capture range Results confirmed that patient risk from UCS is at an acceptable level Gradient Stimulation Strength Duration Curve Human Body Library Lead Paths 1/1,000 Pulse Amplitude Voltage (V) Capture Preclinical Research Human body models encompassed 2nd to 97th percentile of all human bodies, with ten different lead paths Over 400,000 different lead/body combinations were analyzed to derive a minimal probability of a 0.5 V threshold Gradient Stimulation Range /1,000 Pulse Width Effective Pulse Width (ms)

10 Clinical Trial Demonstrates the Safety of Revo MRI SureScan 26 Study Design Multicenter, randomized, controlled clinical trial designed to evaluate the safety of the Revo MRI SureScan pacing system, including any MRI-related complications, as well as to analyze pacing capture thresholds and sensing amplitude 464 patients received a Revo MRI SureScan pacing system and were then randomized to elective MRI or no MRI, approximately 9-12 weeks post-implant MRI imaging intended to represent commonly used, clinically relevant scans Methods Visit Schedule Percent of Subjects Key Results 100% were free of MRI-related complications (n = 211, p < 0.001) No sustained atrial or ventricular arrhythmias, no asystole, no pacemaker output inhibition, and no electrical resets in the group receiving MRI Minimal changes in pacing capture thresholds, as shown on the following chart Primary Effectiveness End Point: Atrial and Ventricular Capture Threshold Threshold changes pre-mri/control visit to 1-month post-mri/control visit Percent of Subjects MRI Group Control Group Enrollment Implant and Randomization 9-12-Week Visit Pre-MRI Change in Atrial Threshold (V) Change in Ventricular Threshold (V) 2-Month Visit MRI Group MRI Scans Post-MRI Control Group No MRI 1-Week Post-MRI Visit 1-Month Post-MRI Visit 6-Month Post-Implant Visit and Every 6 Months Thereafter No discernible difference between the MRI and control groups Clinical Support

11 Builds upon Medtronic Innovations Medtronic founded First external pacemaker Activitrax pacemaker rate response Thera pacemaker first microprocessor-based, mode switching Kappa pacemaker rate-response via activity and minute ventilation Medtronic CareLink Network MVP promotes intrinsic conduction 2011 Revo MRI Pacing System A History of Innovation MVP Managed Ventricular Pacing Exclusive technology that used Atrial Pacing (AAIR) primarily with DDD pacing only when necessary MVP reduces unnecessary RV pacing by 99% 27 ACC/AHA/HRS guidelines 28 state the need to reduce unnecessary pacing as much as possible. The following studies support the guidelines: MOST 29 : Every incremental 1% of unnecessary VP increases the risk for heart failure hospitalizations by 5.4% and for AF by 1%. CareLink Network* The leading Internet-based remote monitoring service for implanted devices 32 Serving nearly 500,000 patients in 3,000 clinics in the United States * Not all devices are available on the CareLink Network. Danish II 30 : Even with long AV delays, the risk of AF doubles with DDD(R) pacing compared to AAI(R) with DDD(R) backup. Gardiwal 31 : Patients with 72% RV pacing are at increased risk for VT/VF.

12 References 1 Kalin R, Stanton MS. Current clinical issues for MRI scanning of pacemaker and defibrillator patients. PACE. April 2005;28(4): Zhan C, Baine WB, Sedrakyan A, Steiner C. Cardiac device implantation in the United States from 1997 through 2004: a population-based analysis. Gen Intern Med. January 2008;23(suppl 1): Global Industry Analysts, Inc. Magnetic Resonance Imaging (MRI) Equipment A Global Strategic Business Report. San Jose, CA National Cancer Institute April US estimated complete prevalence (including counts) by age on 1/1/2006. Based on November 2008 SEER data submission; DCCPS, Surveillance Research Program, Statistical Research and Applications Branch. 5 Lawrence RC, Helmick CG, Arnett FC, et al. Estimates of the prevalence of arthritis and selected musculoskeletal disorders in the United States. Arthritis Rheum. May 1998;41(5): American Heart Association. Heart Disease and Stroke Statistics 2010 Update: Learn and Live. Prevalence of stroke by age and sex (NHANES: ). 7 Medtronic Revo MRI FDA Panel Pack: CommitteesMeetingMaterials/MedicalDevices/ MedicalDevicesAdvisoryCommittee/ CirculatorySystemDevicesPanel/ucm htm. 8 Medical Imaging Survey, Medicare Fee-for-Service Review, Naehle CP, Zeijlemaker V, Thomas D, et al. Evaluation of cumulative effects of MR imaging on pacemaker systems at 1.5 Tesla. Pacing Clin Electrophysiol. December 2009;32(12): Goldsher D, Jahshan S, Roguin A. Successful cervical MR scan in a patient several hours after pacemaker implantation. Pacing Clin Electrophysiol. October 2009;32(10): Gimbel JR. Unexpected asystole during 3T magnetic resonance imaging of a pacemaker-dependent patient with a modern pacemaker. Europace. September 2009;11(9): Naehle CP, Strach K, Thomas D, et al. Magnetic resonance imaging at 1.5-T in patients with implantable cardioverter-defibrillators. J Am Coll Cardiol. August 4, 2009;54(6): Roguin A. Magnetic resonance imaging in patients with implantable cardioverter-defibrillators and pacemakers. J Am Coll Cardiol. August 4, 2009;54(6): Mollerus M, Albin G, Lipinski M, Lucca J. Cardiac biomarkers in patients with permanent pacemakers and implantable cardioverter-defibrillators undergoing an MRI scan. Pacing Clin Electrophysiol. October 2008;31(10): Pulver AF, Puchalski MD, Bradley DJ, et al. Safety and imaging quality of MRI in pediatric and adult congenital heart disease patients with pacemakers. Pacing Clin Electrophysiol. April 2009;32(4): Nordbeck P, Weiss I, Ehses P, et al. Measuring RF-induced currents inside implants: impact of device configuration on MRI safety of cardiac pacemaker leads. Magn Reson Med. March 2009;61(3): Sutton R, Kanal E, Wilkoff BL, et al. Safety of magnetic resonance imaging of patients with a new Medtronic EnRhythm MRI SureScan pacing system: clinical study design. Trials. December 2, 2008;9(1): Naehle CP, Meyer C, Thomas D, et al. Safety of brain 3-T MR imaging with transmit-receive head coil in patients with cardiac pacemakers: pilot prospective study with 51 examinations. Radiology. December 2008;249(3): Calcagnini G, Triventi M, Censi F, et al. In vitro investigation of pacemaker lead heating induced by magnetic resonance imaging: role of implant geometry. J Magn Reson Imaging. October 2008;28(4): Dyrda K, Khairy P. Implantable rhythm devices and electromagnetic interference: myth or reality? Expert Rev Cardiovasc Ther. July 2008;6(6): Gimbel JR. Magnetic resonance imaging of implantable cardiac rhythm devices at 3.0 tesla. Pacing Clin Electrophysiol. July 2008;31(7): Nordbeck P, Bauer WR. [Safety of cardiac pacemakers and implantable cardioverter-defibrillators in magnetic resonance imaging. Assessment of the aggregate function at 1.5 tesla.] Dtsch Med Wochenschr. March 2008;133(13): [Article in German.] 24 Tandri H, Zviman MM, Wedan SR, Lloyd T, Berger RD, Halperin H. Determinants of gradient field-induced current in a pacemaker lead system in a magnetic resonance imaging environment. Heart Rhythm. March 2008;5(3): Roguin A, Zviman MM, Meininger GR, et al. Modern pacemaker and implantable cardioverter/defibrillator systems can be magnet resonance imaging safe: in vitro and in vivo assessment of safety and function at 1.5 T. Circulation. August 3, 2004;110(5): Medtronic, Inc. Revo MRI SureScan pacing system clinical summary Gillis AM, Pürerfellner H, Israel CW, et al. Reduction of unnecessary right ventricular pacing due to the Managed Ventricular Pacing (MVP) mode in patients with symptomatic bradycardia: benefit for both sinus node disease and AV block indications. Heart Rhythm. 2005;Abstract AB Epstein AE, DiMarco JP, Ellenbogen KA, et al. ACC/ AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices) developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons. J Am Coll Cardiol. May 27, 2008;51(21):e Sweeney MO, Hellkamp AS, Ellenbogen KA, et al. Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation. June 17, 2003;107(23): Nielsen JC, Kristensen L, Andersen HR, Mortensen PT, Pedersen OL, Pedersen AK. A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome: echocardiographic and clinical outcome. J Am Coll Cardiol. August 20, 2003;42(4): Gardiwal A, Yu H, Oswald H, et al. Right ventricular pacing is an independent predictor for ventricular tachycardia/ventricular fibrillation occurrence and heart failure events in patients with an implantable cardioverter-defibrillator. Europace. March 2008;10(3): Medtronic CareLink Metrics Database. Revo MRI Pacing System Conditions for Use A complete Revo MRI SureScan pacing system, including a Revo MRI SureScan IPG and two SureScan leads is required for use in the MRI environment. Any other combination may result in a hazard to the patient during an MRI scan. The SureScan feature must be programmed to On prior to scanning a patient according to the specified conditions for use. Cardiology requirements: Patients and their implanted systems must be screened to meet the following requirements: no previously implanted (active or abandoned) medical devices, leads, lead extenders, or lead adaptors no broken leads or leads with intermittent electrical contact as confirmed by lead impedance history a Revo MRI SureScan pacing system that has been implanted for a minimum of 6 weeks a Revo MRI SureScan pacing system implanted in the left or right pectoral region pacing capture thresholds of 2.0 volts (V) at a pulse width of 0.4 milliseconds (ms) a lead impedance value of 200 ohms (Ω) and 1,500 Ω no diaphragmatic stimulation at a pacing output of 5.0 V and at a pulse width of 1.0 ms in patients whose device will be programmed to an asynchronous pacing mode when MRI SureScan is on Radiology requirements: Horizontal cylindrical bore magnet, clinical MRI systems with a static magnetic field of 1.5 Tesla (T) must be used Gradient systems with maximum gradient slew rate performance per axis of 200 Teslas per meter per second (T/m/s) must be used The scanner must be operated in Normal Operating Mode: The whole body averaged specific absorption rate (SAR) must be 2.0 watts per kilogram (W/kg) The head SAR must be < 3.2 W/kg The patient must be positioned within the bore such that the isocenter (center of the MRI bore) is superior to the C1 vertebra or inferior to the T12 vertebra Proper patient monitoring must be provided during the MRI scan. The methods include visual and verbal contact with the patient, electrocardiography, and pulse oximetry (plethysmography) Training requirements: A health professional who has completed cardiology SureScan training must be present during the programming of the SureScan feature A health professional who has completed radiology SureScan training must be present during the MRI scan Brief Statement Medtronic CareLink Monitor/CareLink Network Intended Use The CareLink Monitor and the CareLink Network are indicated for use in the transfer of patient data from some Medtronic implantable cardiac devices based on physician instructions and as described in the product manual. These products are not a substitute for appropriate medical attention in the event of an emergency and should only be used as directed by a physician. Contraindications There are no contraindications for the CareLink Monitor. Potential complications include, but are not limited to, rejection phenomena, erosion through the skin, muscle or nerve stimulation, oversensing, failure to detect and/or terminate arrhythmia episodes, acceleration of tachycardia, and surgical complications such as hematoma, infection, inflammation, and thrombosis. Warnings and Precautions The CareLink Monitor must only be used for interrogating compatible Medtronic implantable devices. The CareLink Monitor is intended for use within the prescribing country. See the device manual for detailed information regarding the instructions for use, indications, contraindications, warnings, precautions, and potential complications/adverse events. For further information, please call Medtronic at 1 (800) and/or consult Medtronic s website at Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.

Q & A: How to Safely Scan Patients with a SureScan MRI Pacemaker

Q & A: How to Safely Scan Patients with a SureScan MRI Pacemaker Q & A: How to Safely Scan Patients with a SureScan MRI Pacemaker Patient Scheduling and Screening Q: Is there any special (other than regular MRI consent) consent form that should be signed by the patient?

More information

CARDIAC DEVICE MR-CONDITIONAL PRODUCT SUMMARY CHART

CARDIAC DEVICE MR-CONDITIONAL PRODUCT SUMMARY CHART CARDIAC DEVICE MR-CONDITIONAL PRODUCT SUMMARY CHART December 2015 This chart encompasses all Medtronic cardiac devices FDA-Approved as MR Conditional and included in the MRI SureScan portfolio. If a device

More information

Call Medtronic at 1 (800) to verify the patient s current implanted system

Call Medtronic at 1 (800) to verify the patient s current implanted system MRI SURESCAN SYSTEMS Patient Scanning Process Transvenous Implantable Cardiac Systems PATIENT PRESCREENING SureScan Pacing, Defibrillation, and CRT (CRT-D and CRT-P) Systems Verification Verify that patient

More information

MEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring

MEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring MEDTRONIC CARELINK NETWORK FOR PACEMAKERS Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring Transtelephonic Monitoring Transmission What can you determine

More information

EXAMPLE PROTOCOL FOR PATIENT SCANNING PROCESS

EXAMPLE PROTOCOL FOR PATIENT SCANNING PROCESS EXAMPLE PROTOCOL FOR PATIENT SCANNING PROCESS MRI SureScan Pacing, ICD, and CRT (CRT-D and CRT-P) Transvenous Implantable Cardiac Systems Timothy S. E. Albert, M.D. President CVMR Solutions, Inc. Carmel

More information

MRI SURESCAN SYSTEMS. Patient Scanning Process PATIENT PRESCREENING. SureScan Pacing, Defibrillation, and CRT-D Systems Verification

MRI SURESCAN SYSTEMS. Patient Scanning Process PATIENT PRESCREENING. SureScan Pacing, Defibrillation, and CRT-D Systems Verification MRI SURESCAN SYSTEMS Patient Scanning Process PATIENT PRESCREENING SureScan Pacing, Defibrillation, and CRT-D Systems Verification Verify that patient has a complete SureScan pacing, defibrillation, or

More information

ENGINEERED TO ENABLE THE FUTURE OF CONNECTED HEALTH

ENGINEERED TO ENABLE THE FUTURE OF CONNECTED HEALTH ENGINEERED TO ENABLE THE FUTURE OF CONNECTED HEALTH Introducing Azure with BlueSync Technology Completely Redesigned Improved Longevity 1 AF Detection and Reduction 2 Secure Wireless Communication with

More information

Managing Metallic Artifacts in MRI

Managing Metallic Artifacts in MRI Managing Metallic Artifacts in MRI William Faulkner, BS, RT (R) (MR) (CT), FSMRT Background Magnetism is a fundamental property of matter. As such, all substances have some type of magnetic property. Magnetic

More information

Advisa MRI and Ensura MRI SureScan pacing systems

Advisa MRI and Ensura MRI SureScan pacing systems Advisa MRI and Ensura MRI SureScan pacing systems MR Conditional dual chamber and single chamber SureScan pacing systems with SureScan leads MRI Technical Manual The following list includes trademarks

More information

Micra MC1VR01. MRI procedural information for Micra Model MC1VR01 MR Conditional single chamber transcatheter pacing device (VVIR)

Micra MC1VR01. MRI procedural information for Micra Model MC1VR01 MR Conditional single chamber transcatheter pacing device (VVIR) Micra MC1VR01 MRI procedural information for Micra Model MC1VR01 MR Conditional single chamber transcatheter pacing device (VVIR) MRI Technical Manual The following list includes trademarks or registered

More information

CONSULTA CRT-P Model C4TR01

CONSULTA CRT-P Model C4TR01 CONSULTA CRT-P Model C4TR01 Physical characteristics Volume a 15 cm 3 Mass H x W x D Surface area of titanium device can Surface area of each titanium nitride LECG electrode Radiopaque ID Materials in

More information

PACING SYSTEMS.

PACING SYSTEMS. References 1 Ensura SR MRI SureScan EN1SR01 Clinician Manual. 2 Medtronic Adapta ADSR01/03/06 Implant Manual, 2005. 3 Advisa MRI SureScan pacing system included on the ARTG 22/8/2009, with full body MRI

More information

Model 5392 EPG Temporary Pacer

Model 5392 EPG Temporary Pacer Model 5392 EPG Temporary Pacer Compatible Components Reference Card 5392 Surgical Cables 5487 Disposable, short 5487L Disposable, long 5832S Reusable, small clip 5833S 5833SL Disposable, small clip, short

More information

Advisa MRI SureScan. PACING SYSTEMs. References 1

Advisa MRI SureScan. PACING SYSTEMs.  References 1 References 1 Zhan C, Baine WB, Sedrakyan A, Steiner C. Cardiac device implantation in the United States from 1997 through 2004: a population-based analysis. J Gen Intern Med. January 2008;23(Suppl 1):13-19.

More information

MRI SureScan pacemakers & ICDs what you need to know

MRI SureScan pacemakers & ICDs what you need to know MRI SureScan pacemakers & ICDs what you need to know Many variables can affect the device patient s likelihood of risks w/ an MRI Type of imaging sequence Type of scanner MRI scan duration Strength of

More information

11 YEARS PROVEN PERFORMANCE. Sprint Quattro Defibrillation Leads

11 YEARS PROVEN PERFORMANCE. Sprint Quattro Defibrillation Leads 11 YEARS PROVEN PERFORMANCE Sprint Quattro Defibrillation Leads PROVEN PERFORMANCE. PROVEN RELIABLE. We made intentional choices and took proactive steps from lead design to active product monitoring to

More information

MRI ACCESS. Evera MRI SureScan ICD Systems

MRI ACCESS. Evera MRI SureScan ICD Systems ACCESS Evera SureScan ICD Systems ACCESS. 36% of ICD patients are likely to have an ordered over 4 years 3 Introducing Evera, featuring SureScan Technology. ICD Patients are not receiving s 1.4% 36% CONTOURED.

More information

12 YEARS PROVEN PERFORMANCE. Sprint Quattro Defibrillation Leads

12 YEARS PROVEN PERFORMANCE. Sprint Quattro Defibrillation Leads 12 YEARS PROVEN PERFORMANCE Sprint Quattro Defibrillation Leads PROVEN PERFORMANCE. PROVEN RELIABLE. We made intentional choices and took proactive steps from lead design to active product monitoring to

More information

VNS Therapy System Physician s Manual

VNS Therapy System Physician s Manual VNS Therapy System Physician s Manual Pulse Generator Model 102 Pulse Duo Generator Model 102R Demipulse Generator Model 103 Demipulse Duo Generator Model 104 AspireHC Generator Model 105 AspireSR Generator

More information

INTERPRETING THE ECG IN PATIENTS WITH PACEMAKERS

INTERPRETING THE ECG IN PATIENTS WITH PACEMAKERS INTERPRETING THE ECG IN PATIENTS WITH PACEMAKERS BEFORE INTERPRETING THE ECG: Nora Goldschlager, M.D. MACP, FACC, FAHA, FHRS. Cardiology San Francisco General Hospital UCSF Disclosures: None 1 2 QUESTIONS

More information

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System MRI-Ready Systems Manual MRI Procedure Information for the St. Jude Medical MR Conditional System CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician. WARNING: This

More information

PACING AT THE BUNDLE OF HIS

PACING AT THE BUNDLE OF HIS PACING AT THE BUNDLE OF HIS Cardiac Rhythm Heart Failure Coding Corner Disclaimer While Medtronic offers opinions about how to code when using our technology according to its FDA-approved labeling, these

More information

MRI conditional devices. A luxury or a real clinical need? Sophie Mavrogeni, MD, FESC Onassis Cardiac Surgery Center, Athens, Greece

MRI conditional devices. A luxury or a real clinical need? Sophie Mavrogeni, MD, FESC Onassis Cardiac Surgery Center, Athens, Greece MRI conditional devices. A luxury or a real clinical need? Sophie Mavrogeni, MD, FESC Onassis Cardiac Surgery Center, Athens, Greece Increase of MRI scans in recent decades In the USA, the number of procedures

More information

MRI imaging for patients with cardiac implantable electronic devices (CIEDs)

MRI imaging for patients with cardiac implantable electronic devices (CIEDs) MRI imaging for patients with cardiac implantable electronic devices (CIEDs) 13 th annual International Winter Arrhythmia School Collingwood, Ontario, Canada February 6, 2016 Andrew C.T. Ha, MD, MSc, FRCPC

More information

SJM MRI ACTIVATOR HANDHELD DEVICE WORKFLOW Model: EX4000. SJM-EDTR Item approved for U.S. use only.

SJM MRI ACTIVATOR HANDHELD DEVICE WORKFLOW Model: EX4000. SJM-EDTR Item approved for U.S. use only. SJM MRI ACTIVATOR HANDHELD DEVICE WORKFLOW Model: EX4000 1 APPROVED MRI SCAN CONDITIONS 1.5 TESLA FULL BODY 2 SETUP SJM MRI ACTIVATOR HANDHELD DEVICE The SJM MRI Activator handheld device must be enabled

More information

Programming of Bradycardic Parameters. C. W. Israel, M.D. Dept. of Cardiology Evangelical Hospital Bielefeld Germany

Programming of Bradycardic Parameters. C. W. Israel, M.D. Dept. of Cardiology Evangelical Hospital Bielefeld Germany Programming of Bradycardic Parameters C. W. Israel, M.D. Dept. of Cardiology Evangelical Hospital Bielefeld Germany Carsten.Israel@evkb.de Programming of ICD Brady Parameters Conflict of Interest Biotronik

More information

Percepta CRT-P MRI SureScan W1TR01

Percepta CRT-P MRI SureScan W1TR01 Percepta CRT-P MRI SureScan W1TR01 MR Conditional pacemaker with cardiac resynchronization therapy, SureScan technology, and Bluetooth wireless telemetry (OAE-DDDR) Device Manual Caution: Federal law (USA)

More information

FREQUENTLY ASKED QUESTIONS MONITORING

FREQUENTLY ASKED QUESTIONS MONITORING Core Devices Pacemakers (PM) Implantable Cardioverter-Defibrillators (ICD) Cardiac Resynchronization Therapy (CRT) devices OptiVol Fluid Status Monitoring FREQUENTLY ASKED QUESTIONS MONITORING SEPTEMBER

More information

Pediatric pacemakers & ICDs:

Pediatric pacemakers & ICDs: Pediatric pacemakers & ICDs: perioperative management Manchula Navaratnam Clinical Assistant Professor LPCH, Stanford SPA 2016 Conflict of interest: none Objectives Indications in pediatrics Components

More information

IMAGEREADY MR CONDITIONAL PACING SYSTEM

IMAGEREADY MR CONDITIONAL PACING SYSTEM CAUTION: Federal law (USA) restricts this device to sale by or on the order of a physician trained or experienced in device implant and follow-up procedures. MRI TECHNICAL GUIDE IMAGEREADY MR CONDITIONAL

More information

MRI and CIEDs. Disclosures

MRI and CIEDs. Disclosures Date Clinical Title MRI and CIEDs C. p. Lao Raul Weiss MD, FAHA, FACC, FHRS and CCDS Director, Electrophysiology Fellowship Program Professor of Medicine The Ohio State University Wexner Medical Center

More information

STANDARD OPERATING PROCEDURE (SOP)

STANDARD OPERATING PROCEDURE (SOP) STANDARD OPERATING PROCEDURE (SOP) MRI Scanning for Patients with Cardiac Implantable Electronic Devices (Pacemakers and Implantable Cardiac Defibrillators) Effective date 05/04/2018 Version number V1.0

More information

Automatic Identification of Implantable Cardioverter-Defibrillator Lead Problems Using Intracardiac Electrograms

Automatic Identification of Implantable Cardioverter-Defibrillator Lead Problems Using Intracardiac Electrograms Automatic Identification of Implantable Cardioverter-Defibrillator Lead Problems Using Intracardiac Electrograms BD Gunderson, AS Patel, CA Bounds Medtronic, Inc., Minneapolis, USA Abstract Implantable

More information

Solara CRT-P MRI SureScan W1TR06

Solara CRT-P MRI SureScan W1TR06 Solara CRT-P MRI SureScan W1TR06 MR Conditional pacemaker with cardiac resynchronization therapy, SureScan technology, and Bluetooth wireless telemetry (OAE-DDDR) Device Manual The following list includes

More information

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs Dear EHRA Member, Dear Colleague, As you know, the EHRA Accreditation Process is becoming increasingly recognised as an important step for

More information

Version überholt. Nicht verwenden. Version obsolète. Ne pas utiliser. Versione obsoleta. Non utilizzare. Verouderde versie. Niet gebruiken.

Version überholt. Nicht verwenden. Version obsolète. Ne pas utiliser. Versione obsoleta. Non utilizzare. Verouderde versie. Niet gebruiken. MRI TECHNICAL GUIDE IMAGEREADY MR CONDITIONAL PACING SYSTEM REF J065, J066, J067, J175, J176, J177, J275, J276, J277, J279, L110, L111, L131, L210, L211, L231, L310, L311, L331, 4456, 4457, 4458, 4459,

More information

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE GUIDANCE EXECUTIVE (GE)

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE GUIDANCE EXECUTIVE (GE) NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE GUIDANCE EXECUTIVE (GE) Review of TA88; Dual-chamber pacemakers for symptomatic bradycardia due to sick sinus syndrome and/or atrioventricular block

More information

MEET MICRA. Micra TM ACTUAL SIZE. Transcatheter Pacing System

MEET MICRA. Micra TM ACTUAL SIZE. Transcatheter Pacing System MEET MICRA ACTUAL SIZE Micra TM Transcatheter Pacing System MEET MICRA The world s smallest pacemaker 1 MINIATURIZED. 93% smaller than modern-day pacemakers 6 Completely self contained within the heart,

More information

Advanced ICD Concepts

Advanced ICD Concepts 1 4 2 5 7 3 6 8 Advanced ICD Concepts This presentation is provided with the understanding that the slide content must not be altered in any manner as the content is subject to FDA regulations. This presentation

More information

Cardiovascular magnetic resonance with an MR compatible pacemaker

Cardiovascular magnetic resonance with an MR compatible pacemaker Washington University School of Medicine Digital Commons@Becker Open Access Publications 2013 Cardiovascular magnetic resonance with an MR compatible pacemaker Anita R. Bhandiwad Kristopher W. Cummings

More information

MEET MICRA. Micra TM ACTUAL SIZE. Transcatheter Pacing System

MEET MICRA. Micra TM ACTUAL SIZE. Transcatheter Pacing System MEET MICRA ACTUAL SIZE Micra TM Transcatheter Pacing System MEET MICRA The world s smallest pacemaker 1 MINIATURIZED. 93% smaller than modern-day pacemakers 7 Completely self contained within the heart,

More information

Clinical Data Summary: Avoid FFS Study

Clinical Data Summary: Avoid FFS Study Atrial Pacing Lead with 1.1 mm Tip-to-Ring Spacing Clinical Data Summary: Avoid FFS Study A Multi-center, Randomized, Prospective Clinical Study Designed to Evaluate the 1699T Lead Clinical Data Summary:

More information

Azure XT DR MRI SureScan W2DR01

Azure XT DR MRI SureScan W2DR01 Azure XT DR MRI SureScan W2DR01 MR Conditional dual chamber pacemaker with SureScan technology and Bluetooth wireless telemetry (OAE-DDDR) Device Manual The following list includes trademarks or registered

More information

Evera MRI S SureScan FIRST. Fit for LIVING. Fit for MRI. ICD SYSTEM

Evera MRI S SureScan FIRST. Fit for LIVING. Fit for MRI. ICD SYSTEM Evera MRI S SureScan ICD SYSTEM Fit for LIVING. Fit for MRI. FULL BODY FIRST MRI ICD It s contoured. 3 reduction in skin pressure, designed for greater patient comfort. 1 It lasts longer. Up to 25% greater

More information

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500) 1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500). ONLY NEVRO CORP. All questions or concerns about Nevro products should be forwarded to: Nevro

More information

Cardiac implantable electronic devices (CIEDs) in children include pacemakers and implantable cardioverter defibrillators (ICDs).

Cardiac implantable electronic devices (CIEDs) in children include pacemakers and implantable cardioverter defibrillators (ICDs). Management of Children with Cardiac Devices Guideline originally developed by Leann Miles, APRN; Lindsey Pumphrey, RN; Srikant Das, MD, and the ANGELS Team. Last reviewed by Lindsey Pumphrey, RN, Srikant

More information

MRI Guidelines for the Axonics Sacral Neuromodulation System

MRI Guidelines for the Axonics Sacral Neuromodulation System MRI Guidelines for the Axonics Sacral Neuromodulation System For Healthcare Professionals Rx only Note: This document is a supplement to the physician manuals provided with the Axonics SNM System. This

More information

MRI for Patients with MRI-Conditional Pacing System: Radiographers Role. Lawrance Yip DM, DR, QMH

MRI for Patients with MRI-Conditional Pacing System: Radiographers Role. Lawrance Yip DM, DR, QMH MRI for Patients with MRI-Conditional Pacing System: Radiographers Role Lawrance Yip DM, DR, QMH MRI & Pacemaker MRI is a crucial and growing imaging modality Plays an important role in clinical management

More information

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART I

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART I 1 PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART I Cynthia Webner DNP, RN, CCNS, CCRN-CMC Karen Marzlin DNP, RN, CCNS, CCRN-CMC 2 PROFESSIONAL NURSING PRACTICE CAN ONLY ADVANCE AS MUCH AS INDIVIDUAL

More information

Cardiac Rhythm Device Management. PBL STOP Your acronym for a standardized follow-up

Cardiac Rhythm Device Management. PBL STOP Your acronym for a standardized follow-up Cardiac Rhythm Device Management PBL STOP Your acronym for a standardized follow-up What s in it for you? What do you need to feel comfortable with a pacemaker/icd follow-up? 2 CORE OBJECTIVE Provide a

More information

Active Fixation Models: 7740, 7741 and 7742 Passive Fixation Models: 7731, 7732, 7735 and 7736

Active Fixation Models: 7740, 7741 and 7742 Passive Fixation Models: 7731, 7732, 7735 and 7736 The INGEVITY MRI pacing leads are 6F (2.0 mm) steroid-eluting, endocardial pace / sense leads designed for permanent implantation for either atrial or ventricular applications. INGEVITY MRI is the only

More information

MICRA TRANSCATHETER PACING SYSTEM (TPS) REIMBURSEMENT OVERVIEW

MICRA TRANSCATHETER PACING SYSTEM (TPS) REIMBURSEMENT OVERVIEW MICRA TRANSCATHETER PACING SYSTEM (TPS) REIMBURSEMENT OVERVIEW MARCH 20, 2017 DISCLAIMER This presentation is intended only for educational use. Any duplication is prohibited without written consent of

More information

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500) 1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500) ONLY NEVRO CORP. All questions or concerns about Nevro products should be forwarded to: Nevro

More information

Lead Management for MRI

Lead Management for MRI Lead Management for MRI Charles J. Love, MD FACC FAHA FHRS CCDS Professor of Medicine Director, Cardiac Rhythm Device Services The Ohio State University Medical Center Columbus, OH USA President, International

More information

Puzzling Pacemakers Cheryl Herrmann, APN, CCRN, CCNS-CSC-CMC

Puzzling Pacemakers Cheryl Herrmann, APN, CCRN, CCNS-CSC-CMC Puzzling Pacemakers Cheryl Herrmann, APN, CCRN, CCNS-CSC-CMC Pacemaker: An electric device implanted in the body to regulate the heart beat. Delivers electrical stimuli over leads with electrodes in contact

More information

Product Performance Report. Implantable devices. Pacing leads. Pacemakers. Defibrillators SNIA GROUP

Product Performance Report. Implantable devices. Pacing leads. Pacemakers. Defibrillators SNIA GROUP Product Performance Report Implantable devices Pacing leads Pacemakers Defibrillators SNIA GROUP A message from the chairman For ELA, quality is an essential criterion in the everyday decision making process.

More information

UNLOCK THE ANSWER. The Reveal LINQ TM System lets your physician learn about your heart while you live your life.

UNLOCK THE ANSWER. The Reveal LINQ TM System lets your physician learn about your heart while you live your life. UNLOCK THE ANSWER The Reveal LINQ TM System lets your physician learn about your heart while you live your life. WHY LONG-TERM MONITORING MAY BE RIGHT FOR YOU Accurate information is the key to better

More information

PERIOPERATIVE MANAGEMENT: CARDIAC PACEMAKERS AND DEFIBRILLATORS

PERIOPERATIVE MANAGEMENT: CARDIAC PACEMAKERS AND DEFIBRILLATORS PERIOPERATIVE MANAGEMENT: CARDIAC PACEMAKERS AND DEFIBRILLATORS DR SUSAN CORCORAN CARDIOLOGIST ONCE UPON A TIME.. Single chamber pacemakers Programmed at 70/min VVI 70 UNIPOLAR SYSTEMS A Unipolar Pacing

More information

MRI GUIDELINES FOR INSPIRE THERAPY

MRI GUIDELINES FOR INSPIRE THERAPY MRI GUIDELINES FOR INSPIRE THERAPY Clinician s Manual ONLY The following is a trademark of Inspire Medical Systems, Inc.: Inspire Introduction Read the information in this manual prior to conducting an

More information

EnTrust D154VRC Single Chamber ICD 35J delivered 8 seconds BOL, 11.8 seconds ERI 10.7 years**** 35cc, 68g Programmable Active Can

EnTrust D154VRC Single Chamber ICD 35J delivered 8 seconds BOL, 11.8 seconds ERI 10.7 years**** 35cc, 68g Programmable Active Can EnTrust D154ATG Dual Chamber ICD 35J delivered 8 seconds BOL, 11 seconds ERI 7.7 years** 35cc***, 68g Programmable Active Can EnTrust D154VRC Single Chamber ICD 35J delivered 8 seconds BOL, 11.8 seconds

More information

Diagnostic capabilities of the implantable therapeutic systems

Diagnostic capabilities of the implantable therapeutic systems Cardiac pacing 2012 and beyound Monday August 27, 2012 Diagnostic capabilities of the implantable therapeutic systems Pekka Raatikainen Heart Center Co. Tampere University Hospital and University of Tampere

More information

Magnetic resonance imaging of pacemakers and implantable cardioverter-defibrillators without specific absorption rate restrictions

Magnetic resonance imaging of pacemakers and implantable cardioverter-defibrillators without specific absorption rate restrictions Europace (2010) 12, 947 951 doi:10.1093/europace/euq092 CLINICAL RESEARCH Pacing and CRT Magnetic resonance imaging of pacemakers and implantable cardioverter-defibrillators without specific absorption

More information

Leadless pacing: Technical challenges and concerns. Panos Vardas President Elect of the ESC, Prof. of Cardiology, Heraklion University Hospital

Leadless pacing: Technical challenges and concerns. Panos Vardas President Elect of the ESC, Prof. of Cardiology, Heraklion University Hospital Leadless pacing: Technical challenges and concerns Panos Vardas President Elect of the ESC, Prof. of Cardiology, Heraklion University Hospital Modest consultancy fees/honoraria from Bayer Boehringer Ingelheim

More information

Essentials of Pacemakers and ICD s. Rajesh Banker, MD, MPH

Essentials of Pacemakers and ICD s. Rajesh Banker, MD, MPH Essentials of Pacemakers and ICD s Rajesh Banker, MD, MPH Pacemakers have 4 basic functions: Stimulate cardiac depolarization Sense intrinsic cardiac function Respond to increased metabolic demand by providing

More information

Industry-Tested. Stacks Up To the Competition 2

Industry-Tested. Stacks Up To the Competition 2 With READY TM Industry-Tested Stacks Up To the Competition 2 INGEVITY TM MRI Pacing Lead, the industry s leading-edge pacing technology, 1 is also the most extensively studied. 2 % of leads 10% 9% 8% 7%

More information

Evera MRI XT SureScan ICD SYSTEM

Evera MRI XT SureScan ICD SYSTEM References 1 Flo, Daniel. Device Shape Analysis. January 2013. Medtronic data on file. 2 Evera MRI DR/VR ICD Manuals. Protecta DR/VR ICD Manuals. 3 Schloss EJ, Auricchio A, Kurita T, et al. PainFree SST

More information

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System MRI-Ready Systems Manual MRI Procedure Information for the St. Jude Medical MR Conditional System Unless otherwise noted, indicates that the name is a trademark of, or licensed to, St. Jude Medical or

More information

Devices and EP- Safety in MRI

Devices and EP- Safety in MRI Devices and EP- Safety in MRI Mohammad Shenasa M.D. FACC, FHRS, FESC O Connor Hospital San Jose, CA Biblioteca-Alexandria Alexandria-Egypt Cardio Alex June 10-13, 2014 Effect of External Electrical and

More information

Azure S DR MRI SureScan W3DR01

Azure S DR MRI SureScan W3DR01 Azure S DR MRI SureScan W3DR01 MR Conditional dual chamber pacemaker with SureScan technology and Bluetooth wireless telemetry (OOE-DDDR) Device Manual The following list includes trademarks or registered

More information

New generations pacemakers and ICDs: an update

New generations pacemakers and ICDs: an update Advances in Cardiac Arrhythmias and Great Innovations in Cardiology XXVII Giornate Cardiologiche Torinesi New generations pacemakers and ICDs: an update Prof. Fiorenzo Gaita, MD Division of Cardiology

More information

Leadless pacing. P.E. Vardas Professor of Cardiology University of Crete, Greece

Leadless pacing. P.E. Vardas Professor of Cardiology University of Crete, Greece Leadless pacing P.E. Vardas Professor of Cardiology University of Crete, Greece DISCLOSURES Small teaching fees from: Bayer/J&J, Boeringer, Menarini Small consulting fees from: Medtronic 1957: First External

More information

ICD: Basics, Programming and Trouble-shooting

ICD: Basics, Programming and Trouble-shooting ICD: Basics, Programming and Trouble-shooting Amir AbdelWahab, MD Electrophysiology and Pacing Service Cardiology Department Cairo University Feb 2013 Evolution of ICD Technology ICD Evolution Indications

More information

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System MRI-Ready Systems Manual MRI Procedure Information for the St. Jude Medical MR Conditional System Unless otherwise noted, indicates that the name is a trademark of, or licensed to, St. Jude Medical or

More information

ΤΟ ΗΚΓ ΣΤΟΝ ΒΗΜΑΤΟΔΟΤΟΥΜΕΝΟ ΑΣΘΕΝΗ

ΤΟ ΗΚΓ ΣΤΟΝ ΒΗΜΑΤΟΔΟΤΟΥΜΕΝΟ ΑΣΘΕΝΗ ΤΟ ΗΚΓ ΣΤΟΝ ΒΗΜΑΤΟΔΟΤΟΥΜΕΝΟ ΑΣΘΕΝΗ ΤΖΩΡΤΖ ΔΑΔΟΥΣ ΕΠΙΚΟΥΡΟΣ ΚΑΘΗΓΗΤΗΣ Α.Π.Θ. ΜΑΡΙΑ ΚΑΡΑΛΙΟΛΙΟΥ ΕΙΔΙΚΕΥΟΜΕΝΗ ΙΑΤΡΟΣ ΚΑΡΔΙΟΛΟΓΟΣ Β ΚΑΡΔΙΟΛΟΓΙΚΗ ΚΛΙΝΙΚΗ Α.Π.Θ. ΙΠΠΟΚΡΑΤΕΙΟ Γ.Ν.Θ. 5 Why a Pacemaker is Implanted

More information

HOW TO PERFORM HIS-BUNDLE PACING. Training Presentation

HOW TO PERFORM HIS-BUNDLE PACING. Training Presentation HOW TO PERFORM HIS-BUNDLE PACING Training Presentation AGENDA Overview of His-Bundle Pacing SelectSecure Lead Overview C315 Catheter Family Overview His-Bundle Pacing Implant Technique Including locating

More information

Pediatric Pacemaker Implantation Endocardial or Epicardial

Pediatric Pacemaker Implantation Endocardial or Epicardial Pediatric Pacemaker Implantation Endocardial or Epicardial HAITHAM BADRAN, MD, FEHRA CONSULTANT OF INTERVENTIONAL CARDIOLOGY CONSULTANT OF CARDIAC PACING AND ELECTROPHYSIOLOGY LECTURER OF CARDIOLOGY AIN

More information

MODEL EPG SINGLE CHAMBER TEMPORARY EXTERNAL PACEMAKER

MODEL EPG SINGLE CHAMBER TEMPORARY EXTERNAL PACEMAKER MODEL 53401 EPG SINGLE CHAMBER TEMPORARY EXTERNAL PACEMAKER In-service Guide 53401 TRAINING LEARNING OBJECTIVES Identify the control knobs and be able to explain how to use them to program device. Distinguish

More information

Pocket Adaptor Kit FOR SPINAL CORD STIMULATION. Tip Cards

Pocket Adaptor Kit FOR SPINAL CORD STIMULATION. Tip Cards Pocket Adaptor Kit FOR SPINAL CORD STIMULATION Tip Cards model 74001 (1 4) model 74002 (2 4) The Pocket Adaptor Tip Cards are to be used for educational purposes only. Please refer to the Pocket Adaptor

More information

Review of Pacemakers and ICD Therapy: Overview and Patient Management

Review of Pacemakers and ICD Therapy: Overview and Patient Management Review of Pacemakers and ICD Therapy: Overview and Patient Management Pacing Systems Charles J. Love, MD FACC FAHA FHRS CCDS Professor of Medicine Director, Cardiac Rhythm Device Services OSU Division

More information

WHAT CAN I DO ABOUT ATRIAL FIBRILLATION? Finding answers about atrial fibrillation

WHAT CAN I DO ABOUT ATRIAL FIBRILLATION? Finding answers about atrial fibrillation WHAT CAN I DO ABOUT ATRIAL FIBRILLATION? Finding answers about atrial fibrillation DEBBIE S STORY With a full schedule of entertaining friends, dancing, working as a nurse and babysitting her granddog,

More information

M Series with Rectilinear Biphasic Waveform Defibrillator Option Indications for Use

M Series with Rectilinear Biphasic Waveform Defibrillator Option Indications for Use DEFIBRILLATOR OPTION General Information Introduction M Series products are available with an advanced electrical design that provides a unique rectilinear biphasic waveform for defibrillation and cardioversion.

More information

Read this manual before performing an MRI scan on a patient implanted with an Algovita Spinal Cord Stimulation System.

Read this manual before performing an MRI scan on a patient implanted with an Algovita Spinal Cord Stimulation System. Algovita Spinal Cord Stimulation System MRI Procedure Guidelines Read this manual before performing an MRI scan on a patient implanted with an Algovita Spinal Cord Stimulation System. ONLY 0300-000175-001

More information

Algovita. MRI Procedure Guidelines. Spinal Cord Stimulation System. 201x

Algovita. MRI Procedure Guidelines. Spinal Cord Stimulation System. 201x Algovita Spinal Cord Stimulation System MRI Procedure Guidelines Read this manual before performing an MRI scan on a patient implanted with an Algovita Spinal Cord Stimulation System. ONLY 201x Algovita

More information

Safety Issue of Static Magnetic Field (1)

Safety Issue of Static Magnetic Field (1) MRI Safety Safety Issue of Static Magnetic Field (1) Currently, typical MRI utilizes static field with strengths of 0.5 to 3 Tesla (FDA guideline is max 4 T for infants < 1 month and 8 T for others) 1

More information

Perioperative Management of Cardiac Implantable Devices

Perioperative Management of Cardiac Implantable Devices Financial Disclosures Breandan Sullivan MD Assistant Professor Co Director Cardiothoracic and Vascular Surgery ICU Department of Anesthesiology and Critical Care Medicine University of Colorado None Perioperative

More information

The heart's "natural" pacemaker is called the sinoatrial (SA) node or sinus node.

The heart's natural pacemaker is called the sinoatrial (SA) node or sinus node. PACEMAKER Natural pacemaker: The heart's "natural" pacemaker is called the sinoatrial (SA) node or sinus node. Artificial pacemaker: It is a small, battery-operated device that helps the heart beat in

More information

MRI GUIDELINES FOR INSPIRE THERAPY

MRI GUIDELINES FOR INSPIRE THERAPY MRI GUIDELINES FOR INSPIRE THERAPY Clinician s Manual The following is a trademark of Inspire Medical Systems, Inc.: Inspire This product and/or the use of this product in a method may be covered by one

More information

Figure 2. Normal ECG tracing. Table 1.

Figure 2. Normal ECG tracing. Table 1. Figure 2. Normal ECG tracing that navigates through the left ventricle. Following these bundle branches the impulse finally passes to the terminal points called Purkinje fibers. These Purkinje fibers are

More information

PARAD/PARAD+ : P and R Based Arrhythmia Detection

PARAD/PARAD+ : P and R Based Arrhythmia Detection Tech Corner PARAD/PARAD+ : P and R Based Arrhythmia Detection NOTE: PLEASE NOTE THAT THE FOLLOWING INFORMATION IS A GENERAL DESCRIPTION OF THE FUNCTION. DETAILS AND PARTICULAR CASES ARE NOT DESCRIBED IN

More information

Cardiac Implanted Electronic Devices Pacemakers, Defibrillators, Cardiac Resynchronization Devices, Loop Recorders, etc.

Cardiac Implanted Electronic Devices Pacemakers, Defibrillators, Cardiac Resynchronization Devices, Loop Recorders, etc. Cardiac Implanted Electronic Devices Pacemakers, Defibrillators, Cardiac Resynchronization Devices, Loop Recorders, etc. The Miracle of Living February 21, 2018 Matthew Ostrom MD,FACC,FHRS Division of

More information

Leadless Pacing. Osama Diab Assistant Prof. of Cardiology Ain Shams University Egypt

Leadless Pacing. Osama Diab Assistant Prof. of Cardiology Ain Shams University Egypt Leadless Pacing Osama Diab Assistant Prof. of Cardiology Ain Shams University Egypt The weakest link in Pacemaker system the lead. The more the leads the more the complications Dislodgement Fracture Insulation

More information

Implantable Cardioverter-Defibril. Defibrillators. Ratko Magjarević

Implantable Cardioverter-Defibril. Defibrillators. Ratko Magjarević Implantable Cardioverter-Defibril Defibrillators Ratko Magjarević University of Zagreb Faculty of Electrical Engineering and Computing Croatia ratko.magjarevic@fer.hr Ventricular Fibrillation Ventricular

More information

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing Key Points Defibrillators: - know the definition & electrical value of a joule - monophasic vs biphasic types:

More information

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing. D. J. McMahon cewood rev

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing. D. J. McMahon cewood rev Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing D. J. McMahon 141001 cewood rev 2017-10-04 Key Points Defibrillators: - know the definition & electrical value

More information

Pacing and Device Jargon Made Simple. Dr Jonathan Timperley MB ChB MD FRCP Consultant Cardiologist Northampton General Hospital

Pacing and Device Jargon Made Simple. Dr Jonathan Timperley MB ChB MD FRCP Consultant Cardiologist Northampton General Hospital Pacing and Device Jargon Made Simple Dr Jonathan Timperley MB ChB MD FRCP Consultant Cardiologist Northampton General Hospital Disclosure Dr Jonathan Timperley Honorarium from Bayer Arne Larson (1915

More information

Size (mm) (H W D) Mass (g) Volume (cc)

Size (mm) (H W D) Mass (g) Volume (cc) The FORMIO pacing system from Boston Scientific provides an ImageReady * MR conditional pacing system. FORMIO offers RightRate the newest generation of MV sensor technology, and the only MV sensor clinically

More information

ICD leads survival and troubles in the last 10 years

ICD leads survival and troubles in the last 10 years XVI Symposium on Progress in Clinical Pacing, Rome, Italy - Dec 2 to 7, 2014 ICD leads survival and troubles in the last 10 years Antonio Raviele, MD, FESC, FHRS President ALFA Alliance to Fight Atrial

More information

A SIMPLE SOLUTION FOR CARDIAC MONITORING

A SIMPLE SOLUTION FOR CARDIAC MONITORING A SIMPLE SOLUTION FOR CARDIAC MONITORING SEEQ Mobile Cardiac Telemetry System Actual size. NOW THERE S AN EXTERNAL HEART MONITOR THAT S AS SIMPLE TO WEAR AS A BANDAGE It s called the SEEQ Mobile Cardiac

More information

WHY AM I FAINTING? Finding answers about unexplained fainting

WHY AM I FAINTING? Finding answers about unexplained fainting WHY AM I FAINTING? Finding answers about unexplained fainting PERSONAL STORIES For about 15 years, Lloyd s friends and family thought he was clumsy. Each spring, he seemed to have an unusual accident.

More information

November 2016 POWERFULLY SIMPLE CARDIAC MONITORING. SEEQ External Cardiac Monitor (ECM) System. From the leaders who brought you Reveal LINQ ICM

November 2016 POWERFULLY SIMPLE CARDIAC MONITORING. SEEQ External Cardiac Monitor (ECM) System. From the leaders who brought you Reveal LINQ ICM November 2016 POWERFULLY SIMPLE CARDIAC MONITORING SEEQ External Cardiac Monitor (ECM) System From the leaders who brought you Reveal LINQ ICM TRADITIONAL HOLTER MONITORING TYPICALLY 1-2 DAYS NOT LONG

More information