Key words: catheterization; diastole; electrical impedance; magnetic resonance imaging; pulmonary hypertension; tomography

Size: px
Start display at page:

Download "Key words: catheterization; diastole; electrical impedance; magnetic resonance imaging; pulmonary hypertension; tomography"

Transcription

1 Noninvasive Assessment of Right Ventricular Diastolic Function by Electrical Impedance Tomography* Anton Vonk Noordegraaf, MD; Theo]. C. Faes, PhD; Andre Janse, MSc; Johan T. Marcus, PhD; Jean G. F. Bronzwaer, MD; Pieter E. Postmus, MD, FCCP; and Peter M.]. M. de Vries, MD Study objectives: Electrical impedance tomography (EIT) offers the possibility to study blood volume changes within the right atrium during the cardiac cycle. The aim of this study was to determine the applicability of EIT in the assessment of right ventricular diastolic function in COPD. Design: By means of region of interest analysis, impedance changes within the right atrium during the cardiac cycle were plotted as a function of time. As a diastolic index of the right ventricle, the right atrium emptying volume (RAEV), defined as the ratio between the volume change during the rapid filling phase relative to the total ventricular filling volume, was calculated. In a first study, the validity of the EIT method was assessed by comparison of the RAEV measured by EIT and MRI in a group of eight patients with severe COPD and seven control subjects. A second study was undertaken to assess the relation between RAEV and pulmonary artery pressure in a group of 27 patients measured by right-sided heart catheterization. Results: The correlation coefficient between RAEV measured with MRI and EIT was The difference between RAEV measured by MRI and EITwas 8.3±15.7% (mean±sd) for the control subjects and 3.5± 10.9% for the COPD patients. RAEV values measured by EIT and MRI were larger in the control group (47.1±7.6%) compared with the patient group (38.1±10.4%). There was a clear nonlinear relationship between RAEV and the pulmonary artery pressure (y=315 x- 0 6\ r=0.83, p<0.001). Conclusion: Our results indicate that RAEV measured by EIT is a useful noninvasive and inexpensive method for assessing right ventricular diastolic function in COPD patients. (CHEST 1997; 111: ) Key words: catheterization; diastole; electrical impedance; magnetic resonance imaging; pulmonary hypertension; tomography Abbreviations: EIT=electrical impedance tomography; mpap = mean pulmonary artery pressure; PAP = pulmonary artery pressure; PH=pulmonary hypertension; RAEV=right atrium emptying volume; ROC=receiver operating characteristic; ROI=region of interest; RV = right ventricle T he development of a pulmonary hypertension (PH), leading to a clinical cor pulmonale, is a frequently observed complication in patients with COPD. The primary mechanisms for these complications are vasoconstriction and changes in structure *From the Departments of Pulmonary Medicine (Drs.Vonk Noordegraaf, Janse, Postmus, and de Vries), Medical Physics and Informatics (Drs. Faes and Marcus), and Cardiology (Dr. Bronzwaer), Institute for Cardiovascular Research (ICAR-VU), Academic Hospital Vrije Universiteit, Amsterdam, the Netherlands. Supported by Glaxo Wellcome pic, the Netherlands. Manuscript received August 9, 1996; revision accepted December 30. Reprint requests: Peter M.]. M. de Vries, MD, PhD, Academic Hospital Vrije Unit;ersiteit, Department of Pulmonary Medicine, PO Box 7057, 1007MB Amsterdam, the Netherlands of the microarterial bed causing a reduction of the pulmonary vascular bed. 1 Patients with cor pulmonale have low right ventricular (RV) distensibility, which is an important factor determining the activity and prognosis of the patient. 2 Accurate monitoring of reductions in RV distensibility will help in providing a proper management of the cardiovascular system throughout the clinical course of COPD. Among the methods presently available, echo Doppler has gained the widest acceptance in the study of RV diastolic dysfunction. 3 The principle of this technique is based on the characteristic biphasic appearance of trans-tricuspid flow velocities. The ratio between the early diastolic, or "passive" flow, and late diastolic, or "active" flow, is used as a measure of ventricular distensibility. However, it is 1222

2 difficult to obtain satisfactory tricuspid flow patterns in COPD patients by means of echo-doppler. Other t echniques that have the possibility to assess the diastolic function of the RV are MRI 4 and multigated equilibrium radionuclide ventriculography with Krypton-8lm ( 8 1 mkr). 5 In contrast with echo-doppler, these techniques make it possible to calculate the volume patterns over the tricuspid valves. Takao et al 5 showed that the right atrium emptying volume (RAEV), defined as the ratio between the volume change during the rapid filling phase relative to the total ventricular filling volume, not only provides information about the RV diastolic function, but is also a useful test to predict pulmonary artery pressure (PAP). 5 However, MRI and multigated equilibrium radionuclide ventriculography with 8 1 mkr are expensive, making them less suitable for routine monitoring in clinical practice. ECG-gated electrical impedance tomography (EIT) is a n ew impedance imaging technique that produces cross-sectional images of the e lecbical impedance distribution within the plane spanned by the e lectrodes. Applied at the thorax, the EIT method offers the possibility to localize visually ventricular and right atrium volume changes during the cardiac cycle.6-9 The method makes it possible to detect the three clinical phases of the diastole: (1) the rapid filling phase; (2) the slow filling phase; and (3) the atrial contraction. 9 From these data, it is possible to calculate RAEV by means of EIT (RAEVEIT). In comparison with other noninvasive techniques used for the estimation of RV diastolic function, EIT could have several advantages. First, the method is inexpensive. Second, the method is easy to transport and applicable in a way similar to ECG. The present study was undertaken to determine the applicability of EIT in the assessment of RV diastolic function in COPD. In a first study, the validity of the EIT method to measure diastolic function in COPD patients, was assessed by comparing EIT (RAEVEIT) with MRI (RAEVMRI ) results in a group of patients with severe COPD and control subjects. A second study was undertaken to assess the predictive value of RAEVEIT in the diagnosis of PH. Patients MATERIALS AND METHODS Seven healthy male subjects ( mean age. 63.8±7.4 years ) without any s ign of cardiac or respiratory diseases and eight COPD patients (seven m en and one woman; mean age, 63.4±9.6 years) were included for the MRI protocol. Functional cri teria for COPD were as follows: increased total lung capacity (> 110% of predicted ); increased residual volume with a esidual r volume/ total lung capacity ratio of > 0.40, associated with an obstructive spirographic pattern measured b y the ratio of FEV 1 to vital capacity of -s0.40. Twenty-seven patients scheduled for a diagnostic right-sided heart catheterization were included in the second part of the study. They w ere in clinically s table condition and showed sinus rhythm. Reasons for right-sided h eart catheterization were development of dyspnea after previous infarction (18 patients ), evaluation of severe valvular disease (seven patients), one patient with prima1y PH, and one patient \vith chronic pulmonary embolism. The research protocol was approved by the institutional human ethics committee. All patients gave their informed consent. Study Design In the first p art of the study, we tested the valiclity of the EIT method to measure RV diastolic function in COPD patients. Therefore, we compared the volume, of the rapid filling phase expressed as a percentage of stroke volume, both calculated by MRI (RAEVMRI) with RAEVEIT. As EIT and MRI measurements could not be performed simultaneously, EIT measurements were carried out immediately after the MRI session with the patient in the same position. In the second part of the study, the relationship between RAEVEIT and PAP was studied. PAP was measured in a group of cardiologic patients scheduled for right-sided heart catheterization, as this procedure is not performed routinely in COPD patients in our institute. EIT measurements were carried out 1 h after right-sided heart catheterization under the same baseline conditions as during the catheterization; the patient remained in the supine position. Heart rate measured during catheterization did not vary more than five beats compared with EIT measurements. To determine the interobserver v ariation, EIT data were processed by two independent observers. Both obse1vers were blinded for the PAP data measured during right-sided heart catheterization. EIT EIT measurements were performed with the same equipment (Sheffield Applied Potential Tomograph; DAS-01P Portable Data Acquisition System; Mark I; IBEES; Sheffield, England). o.u Measurements were made using an array of 16 equidistantly spaced electrodes around the thorax. In this study, the e lectrodes were attached in an oblique circular plane defined at the level of the ictus cordis anteriorly and 10 em higher posteriorly. 9 A current source, which generates a harmonic current (50 khz, 5 ma peak-peak), was used to measure impedance. Data collection was synchronized \vith the R wave of the ECG. Two hundred cardiac cycles were a veraged to obtain one complete data set. One data set contained 30 images spaced 40 ms in time. Each image visualizes the impedance distribution \vithin the thorax. The total EIT protocol lasted 15 min. The subjects were breathing normally during the measurements. To gain visual and quantitative information of the volume changes in the atria, the follo\ving steps were necessary. First, the EIT required the definition of a r eference data set. All images were reconstructed r elative to this data set. In our study, we defined the reference data set as the average value of the first five frames (end-diastole). In the produced images, the color blue indicated an increase and the color r ed a de crease of impedance relative to end-diastole. Since impedance and blood volume a re inversely proportional, a blood volume decrease in the ventricles during systole causing a n impedance increase was visualized as a blue color. At the same time, a blood volume increase in the atria CHEST I 111 I 5 I MAY,

3 EIT MRI,.-.. $ d) bj)..d u d) time (s) J d) c.c systole III diastole FIGURE 1. Top right: an MRI image, for orientation made in the same oblique plane as the EIT image. The letters RA, RV, LV, and LA are used to indicate the right atrium and ventricle and the left atrium and ventricle, respectively. Top left: EIT image made at end-systole represented as the difference to an end-diastolic reference. During systole, blood volume decreases in th e ventricles, appearing as an increase in impedance (blue), and blood volume increases in the atria, appearing as a decrease in impedance ( red). The right atrial region in the image is demarcated. Bottom: impedance changes during the cardiac cycle within the right atrial region as a function of tim e. The systolic part and the three phases of diastole are indicated in th e curve. RAEVEIT was calculated according to the fo llowing equation: RAEVEIT= {(A-B )/A}X loo. AU=arbitrary unit. 1224

4 causing an impedance decrease was visualized as a red color (Fig 1, left upper image). The MRI image (Fig 1, right upper image) made in the same oblique plane as the EIT image showed the anatomic position of different cardiac compartments. From this MRI image, it is clear that the bilobular blue spot represented the ventricles and the encircled red spot represented the right atrium. 9 To quantify the impedance change within the right atrial region, region of interest (ROI) analysis was performed. An ROI was defined around the right atrial region, including all pixels with impedance values of or less to the region by drawing a contour line automatically (white demarcation in EIT image). The computer calculated the impedance changes within the ROI over the whole sequence of images. The average pixel value of this ROI was plotted as a function of time, to show the impedance change in the right atrial region during the cardiac cycle (Fig 1, bottom). The average pixel value had no unit because it is dimensionless as a consequence of the reconstruction algorithm based on normalized differences. Therefore, the change of the average pixel value in the sequence during the cardiac cycle relative to end-diastole was expressed as an arbitrary unit. We regarded the lowest impedance (A) as the end-systolic impedance. B indicates the impedance at the middle of diastole (the diastolic phase between the rapid filling phase and the atrial contraction). We defined the RAEV (RAEVErT) as the percentage of right atrium outflow in the first half of diastole, relative to the total filling volume ((A-B)/A)XlOO%. Right-Sided Heart Catheterization Right-sided heart catheterization was performed "vith the patient in the supine position with the use a of 7F single-lumen balloon-tipped catheter (Arrow International; Reading, Pa). The mean PAP (mpap) was measured with the patient normally breathing. Pulmonary hypertension was defined as mpap > mmhg. Statistical Analysis Values were expressed as the mean±sd. Correlation analysis was used to analyze the relation between RAEVEIT and RAEVMRI for the healthy subjects and COPD patients. The difference and the SD between both methods were calculated and tested (Mann-Whitney) for the patient and control group separately. Furthermore, the patient data were tested against the control subjects by means of the Mann-\"'hitney test for comparing data from two independent groups. Regression analysis was used to analyze the relation between RAEVEIT (calculated as the mean of the hvo repeated EIT measurements) and mpap. In addition, receiver operating characteristic (ROC) analysis was performed to determine the optimal cutoff level for RAEVEIT to diagnose pulmonary hypertension (mpap > mm Hg) with EIT. To study the interobserver variation, we used the Pearson's correlation coefficienty A p value <0.05 was considered significant. RESULTS Figure 2 shows a scatter plot of RAEVEIT and RAEVMRI results measured in healthy subjects and COPD patients as well as the line of unity. The correlation coefficient between both methods was The difference between both methods was 8.3±15.7% for the healthy subjects and 3.5±10.9% for the COPD patients; both values did not differ significantly from zero (p>0.8). In the control group, RAEV was 47.1±7.6% for EIT and 55.4±14.9% for MRI (p>0.3), and in the COPD group, 38.1±10.4% and 41.6± 16.6% (p>0.3), respectively. The RAEV MRI MRI measurements were performed on a 1-T whole-body system (Impact Expert; Siemens; Erlangen, Germany), using a phased-array body coil. The flow into and out of the RV was evaluated by phase-contrast velocity quantification The RV diastolic filling was evaluated by quantifying the flow into the RV, across the tricuspid valves. The planning of the image plane for the tricuspid flow was similar to the planning for the mitral flow as applied by Fujita et al. 13 MRI phase-contrast velocity quantification (temporal resolution=28 ms; field of view=(300 mm)2; matrix, 230X256) was then applied for the tricuspid flow, v.>ith through-plane velocity encoding of 75 cm/s. At least 35 phases in the cardiac cycle were imaged. The tricuspid flow curve was evaluated as follows: phase unwrapping was first performed if necessary. Then, in each separate time phase of the velocity images, the cross-sectional area of the valvular annulus was delineated by hand, in order to account for translations with respect to the image plane. The spatial mean velocity measured in this area was plotted against time. The volume flow curve was obtained by multiplying the spatial mean velocity times the cross-sectional area. Integrating the volume flow curve over the time interval of rapid filling yielded rapid filling volume. The RV stroke volume was obtained by a similar flow quantification applied for the main pulmonary artery, with the image plane adjusted orthogonally to this artery just before the pulmonary bifurcation. Velocity encoding was 150 cm/s and the volume flow curve was integrated over systole, thus yielding stroke volume. Finally, the rapid filling volume was expressed as percentage of the RV stroke volume (RAEVMRI) , 50 > w L _ L _ L _ L _ L _ RAEVMRI FIGURE 2. Scatterplot between RAEVEIT and RAEVMRI results and the line of unity. The correlation coefficient between both methods was The difference between both methods was 8.3± 15.7% for the healthy subjects and 3.5± 10.9% for the COPD patients; both differences did not differ significantly from zero (p>0.8). CHEST I 111 I 5 I MAY,

5 values, measured by MRI and EIT, were not significantly larger in the control group compared with the patient group (p=0.2). RAEVEIT could not be determined in two cardiologic patients as it was impossible to separate the right atrium region from the surrounding lung region in the EIT image. Both patients were excluded from further analysis. The correlation coefficient between RAEVEIT results obtained from two observers was The relationship between RAEVEIT and the PAP of the 23 cardiologic patients is shown in Fig 3, top. The relation is clearly nonlinear; a multiplicative model y=315 x - o. 64 fitted the data properly with normally distributed residuals (Fig 3, bottom). The correlation coefficient between RAEVEIT and mpap was 0.83 (p<o.ool). PH (defined by a resting mpap of > mm Hg) was present in 10 patients (42% of the cases). The ROC analysis on decreased RAEVEIT in PH is shown in Figure 4. In case the EIT is used as a screening test for the diagnosis of PH, a 100% sensitivity will be preferable. At a cutoff level of RAEVEIT of 45%, a 100% sensitivity and a 79% specificity were reached in the diagnosis of PH by means of EIT y = 315 x -O 64, r = mpap (mmhg) p < DISCUSSION Diastolic abnormalities are one of the earliest manifestations of cardiac dysfunction.1 5 Earlier studies have already shown that the study of the diastolic filling of the RV is clinically useful in evaluating the diastolic function of the heart in COPD Figure l shows that it is possible to study the volume changes in the right atrium by means of ROI analysis. As blood volume changes in the atria and the lungs are in the same direction, impedance changes related to the pulmonary perfusion must be separated to distinguish blood volume changes in the atria. The separation between both regions was based on the difference in magnitude of the impedance changes between both organs, as impedance changes in the right atrium due to the cardiac contraction are larger than impedance changes due to pulmonary perfusion. The pixel value of was chosen as, to our experience, a good separation between blood volume changes in the right atrium and in the lung was obtained in this way. Only in two cardiologic patients was it impossible to separate the , 90 \ \ \ 80 ' t _ L _ L _ L J o L - -' - -' --- ' rnpap (mrnhg) FIGURE 3. Top: scatter diagram showing the relation between RAEVEIT and rnpap (y=315 x- 064, r=0.83, p<o.ool). Bottom: residuals from the regression line plotted against rnpap RAEVEIT FIGURE 4. ROC curve showing the calculated sensitivity and specificity in the diagnosis of PH for different RAEVEIT values. At a cutoff level of 45% RAEVEIT, a 100% sensitivity and a 79% specificity were reached. 1226

6 right atrial region from the surrounding lung region and left atrium in the EIT image by means of automatic contour drawing. According to radionuclide angiography and echo Doppler cardiography studies, we used RAEV as an index of RV diastolic function To exclude subjective interpreting factors, we defined the RAEV (RAEVEIT) as the volume change during the first half of diastole (which resembles the rapid filling volume) relative to the total ventricular filling volume (Fig 1). This might explain the high interobserver agreement as indicated by the correlation coefficient of 0.91 between the results of both observers. Figure 2 shows a good agreement between RAEVEIT and RAEVMRI measurements in the control and COPD patients. The mean value for the difference between both methods did not differ significantly and was not larger for COPD patients than for control subjects. This indicates that changes in thoracic cavity and respiratory movements occurring in COPD patients did not limit the usefulness of EIT. Furthermore, both the RAEVEIT and RAEVMRI were reduced in the COPD group in comparison with the control group, although not significantly, suggesting an altered diastolic RV function in COPD. A reason for the nonsignificant difference between control subjects and patients might be the small number of subjects included in the study. Probably, RV wall hypertrophy and pressure overload play an important factor in the altered diastolic filling of the RV. Therefore, the relation between RAEVEIT and mp AP was assessed. The presence of a clear relationship between RAEVEIT and mpap, measured directly by rightsided heart catheterization, suggests that this technique is useful in estimating PAP noninvasively. The correlation coefficient between RAEVEIT and mpap is in the same order in comparison with other noninvasive techniques as Doppler echocardiographf 17 and 81 mkr-equilibrium radionuclide ventriculography. Since this study was performed to assess the applicability of EIT in patients with COPD, we used the definition of PH defined by Oswald-Mammoser et al.l 8 They defined PH as mpap > mm Hg based on their findings that only % of the emphysematous patients show a resting mpap > mm Hg. The results of the ROC analysis suggest that RAEVEIT can be a sensitive and specific predictor in the diagnosis of PH. Whereas EIT is much less expensive than other a p r o to a cassess h e RV s diastolic function (MRI and 8 mkr-equilibrium radionuclide ventriculography), this method makes it possible to assess RV diastolic function in large groups of COPD patients. This not only offers the possibility to monitor therapeutic effects on RV diastolic function in COPD patients but also to diagnose cardiac dysfunction in an early stage of the disease. CONCLUSION In conclusion, our results indicate that EIT might be a useful noninvasive and inexpensive method for assessing RV diastolic function in COPD patients. Furthermore, the relationship between RAEVEIT and PAP indicates that the level of RAEVEIT allows estimation of PAP and might be a useful tool in the diagnosis of PH. REFERENCES Reid LM. Structure and function in pulmonary hypertension: new perceptions. Chest 1986; 89: Fishman AP. Chronic cor pulmonale. Am Rev Respir Dis 1976; 60: Marangoni S, Scalvini S, Schena M, et al. Right ventticular diastolic function in chronic obstructive lung disease. Eur Respir J 1992; 5: Mostbeck GH, Hartiala JJ, Foster E, et al. Right ventricular diastolic filling: evaluation with velocity-encoded cine MRI. J Comput Assist Tomogr 1993; 17: Takao M, Miyahara Y, Hinboku H, et al. Noninvasive assessment of right heart function by 81 MKr equilibrium radionuclide ventriculography in chronic pulmonary disease. Chest 1996; 109: Eyiiboglu BM, Brown BH, Barber DC. In vivo imaging of cardiac related impedance changes. IEEE Eng Med Bioi 1989; 15: McArdle FJ. Investigation of imaged conductivity changes due to volume changes of the heart. In: McArdle FJ, ed. Investigation on carcliosynchronous images of the heart and head using applied potential tomography (thesis ). Sheffield: Univ of Sheffield, 1992; Eyiiboglu BM, Brown BH, Barber DC, e t al. Localization of cardiac related impedance changes in the thorax. Clin Phys Physiol Meas 1987; 8A: Vonk Noordegraaf A, Faes TJC, Janse A, et al. Improvement of cardiac imaging in electtical impedance tomography by means of a new electrode configuration. Physiol Meas 1996; 17: Brown BH, Seagar AD. The Sheffield data collection system. Clin Phys Physiol Meas 1987; 8A: Smith RWM, Freeston IL, Brown BH. A real time electrical impedance tomography system for clinical use-design and preliminary results. IEEE Biomed 1995; BME-31: Van Rossum AC, Sprenger M, Visser FC, et al. An in dvo validation of quantitative blood flow imaging in arteries and veins using magnetic resonance phase-shift techniques. Eur Heart J 1991; 12: Fujita N, Chazouilleres AF, Hartiala JJ, et al. Quantification of mitral regurgitation by velocity-encoded cine nuclear magnetic resonance imaging. J Am Coli Cardiol 1994; 23: Snedecor KS, Gibson DC. Statistical methods. Ames, Iowa: Iowa State Univ Press, 1989; King KS, Gibson DC. Impairment of diastolic function by CHEST/111/5/MAY,

7 shortened filling period in severe left ventricular disease. Br Heatt J 1989; 62: Berger HJ, Matthay RA, Loke J, et a!. Assessment of cardiac performance \vith quantitative radionuclide angiography: right ventricular ejection fraction with reference to findings in chronic obstructive pulmonary disease. Am J Cardiol 1978; 41: Eysmann SB, Palevsky HI, Reichek N, eta!. Echo/Doppler and hemodynamic correlates of vasodilator responsiveness in primary pulmonary hypertension. Chest 1991; 99: Oswald-Mammoser M, Apprill M, Bachez P, et al. Pulmonaty hemody11amics in chronic obstructive pulmonary disease of the emphysematous type. Respiration 1991; 58:

Improvement of cardiac imaging in electrical impedance tomography by means of a new

Improvement of cardiac imaging in electrical impedance tomography by means of a new Home Search Collections Journals About Contact us My IOPscience Improvement of cardiac imaging in electrical impedance tomography by means of a new electrode configuration This content has been downloaded

More information

Policy #: 222 Latest Review Date: March 2009

Policy #: 222 Latest Review Date: March 2009 Name of Policy: MRI Phase-Contrast Flow Measurement Policy #: 222 Latest Review Date: March 2009 Category: Radiology Policy Grade: Active Policy but no longer scheduled for regular literature reviews and

More information

HEMODYNAMIC ASSESSMENT

HEMODYNAMIC ASSESSMENT HEMODYNAMIC ASSESSMENT INTRODUCTION Conventionally hemodynamics were obtained by cardiac catheterization. It is possible to determine the same by echocardiography. Methods M-mode & 2D echo alone can provide

More information

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03 Introduction Cardiac Imaging Modalities Arnaud Bistoquet 12/19/03 Coronary heart disease: the vessels that supply oxygen-carrying blood to the heart, become narrowed and unable to carry a normal amount

More information

General Cardiovascular Magnetic Resonance Imaging

General Cardiovascular Magnetic Resonance Imaging 2 General Cardiovascular Magnetic Resonance Imaging 19 Peter G. Danias, Cardiovascular MRI: 150 Multiple-Choice Questions and Answers Humana Press 2008 20 Cardiovascular MRI: 150 Multiple-Choice Questions

More information

Echocardiography as a diagnostic and management tool in medical emergencies

Echocardiography as a diagnostic and management tool in medical emergencies Echocardiography as a diagnostic and management tool in medical emergencies Frank van der Heusen MD Department of Anesthesia and perioperative Care UCSF Medical Center Objective of this presentation Indications

More information

Right Heart Catheterization. Franz R. Eberli MD Chief of Cardiology Stadtspital Triemli, Zurich

Right Heart Catheterization. Franz R. Eberli MD Chief of Cardiology Stadtspital Triemli, Zurich Right Heart Catheterization Franz R. Eberli MD Chief of Cardiology Stadtspital Triemli, Zurich Right Heart Catheterization Pressure measurements Oxygen saturation measurements Cardiac output, Vascular

More information

Measurement of Ventricular Volumes and Function: A Comparison of Gated PET and Cardiovascular Magnetic Resonance

Measurement of Ventricular Volumes and Function: A Comparison of Gated PET and Cardiovascular Magnetic Resonance BRIEF COMMUNICATION Measurement of Ventricular Volumes and Function: A Comparison of Gated PET and Cardiovascular Magnetic Resonance Kim Rajappan, MBBS 1,2 ; Lefteris Livieratos, MSc 2 ; Paolo G. Camici,

More information

Index of subjects. effect on ventricular tachycardia 30 treatment with 101, 116 boosterpump 80 Brockenbrough phenomenon 55, 125

Index of subjects. effect on ventricular tachycardia 30 treatment with 101, 116 boosterpump 80 Brockenbrough phenomenon 55, 125 145 Index of subjects A accessory pathways 3 amiodarone 4, 5, 6, 23, 30, 97, 102 angina pectoris 4, 24, 1l0, 137, 139, 140 angulation, of cavity 73, 74 aorta aortic flow velocity 2 aortic insufficiency

More information

Cardiac MRI in ACHD What We. ACHD Patients

Cardiac MRI in ACHD What We. ACHD Patients Cardiac MRI in ACHD What We Have Learned to Apply to ACHD Patients Faris Al Mousily, MBChB, FAAC, FACC Consultant, Pediatric Cardiology, KFSH&RC/Jeddah Adjunct Faculty, Division of Pediatric Cardiology

More information

MR Advance Techniques. Cardiac Imaging. Class IV

MR Advance Techniques. Cardiac Imaging. Class IV MR Advance Techniques Cardiac Imaging Class IV Heart The heart is a muscular organ responsible for pumping blood through the blood vessels by repeated, rhythmic contractions. Layers of the heart Endocardium

More information

Cor pulmonale. Dr hamid reza javadi

Cor pulmonale. Dr hamid reza javadi 1 Cor pulmonale Dr hamid reza javadi 2 Definition Cor pulmonale ;pulmonary heart disease; is defined as dilation and hypertrophy of the right ventricle (RV) in response to diseases of the pulmonary vasculature

More information

Doppler-echocardiographic findings in a patient with persisting right ventricular sinusoids

Doppler-echocardiographic findings in a patient with persisting right ventricular sinusoids Zurich Open Repository and Archive University of Zurich Main Library Strickhofstrasse 39 CH-8057 Zurich www.zora.uzh.ch Year: 1990 Doppler-echocardiographic findings in a patient with persisting right

More information

MASSACHUSETTS INSTITUTE OF TECHNOLOGY

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Harvard-MIT Division of Health Sciences and Technology HST.542J: Quantitative Physiology: Organ Transport Systems Instructors: Roger Mark and Jose Venegas MASSACHUSETTS INSTITUTE OF TECHNOLOGY Departments

More information

Hemodynamic Assessment. Assessment of Systolic Function Doppler Hemodynamics

Hemodynamic Assessment. Assessment of Systolic Function Doppler Hemodynamics Hemodynamic Assessment Matt M. Umland, RDCS, FASE Aurora Medical Group Milwaukee, WI Assessment of Systolic Function Doppler Hemodynamics Stroke Volume Cardiac Output Cardiac Index Tei Index/Index of myocardial

More information

Right Ventricle Steven J. Lester MD, FACC, FRCP(C), FASE Mayo Clinic, Arizona

Right Ventricle Steven J. Lester MD, FACC, FRCP(C), FASE Mayo Clinic, Arizona Right Ventricle Steven J. Lester MD, FACC, FRCP(C), FASE Mayo Clinic, Arizona 1. In which scenario will applying the simplified Bernoulli equation to the peak tricuspid regurgitation velocity and adding

More information

Fig.1 Normal appearance of RV in SAX:

Fig.1 Normal appearance of RV in SAX: Tutorial 7 - Assessment of the right heart Assessment of the Right heart The right heart assessment clinically and echocardiographically is not a very important part of mainstream cardiology. In the ICU,

More information

Impedance Cardiography (ICG) Application of ICG in Intensive Care and Emergency

Impedance Cardiography (ICG) Application of ICG in Intensive Care and Emergency Impedance Cardiography (ICG) Application of ICG in Intensive Care and Emergency Aim of haemodynamic monitoring in ICU and ED Detection and therapy of insufficient organ perfusion Answers to common cardiovascular

More information

Adel Hasanin Ahmed 1

Adel Hasanin Ahmed 1 Adel Hasanin Ahmed 1 PERICARDIAL DISEASE The pericardial effusion ends anteriorly to the descending aorta and is best visualised in the PLAX. PSAX is actually very useful sometimes for looking at posterior

More information

Brief View of Calculation and Measurement of Cardiac Hemodynamics

Brief View of Calculation and Measurement of Cardiac Hemodynamics Cronicon OPEN ACCESS EC CARDIOLOGY Review Article Brief View of Calculation and Measurement of Cardiac Hemodynamics Samah Alasrawi* Pediatric Cardiologist, Al Jalila Children Heart Center, Dubai, UAE *

More information

HISTORY. Question: What category of heart disease is suggested by the fact that a murmur was heard at birth?

HISTORY. Question: What category of heart disease is suggested by the fact that a murmur was heard at birth? HISTORY 23-year-old man. CHIEF COMPLAINT: Decreasing exercise tolerance of several years duration. PRESENT ILLNESS: The patient is the product of an uncomplicated term pregnancy. A heart murmur was discovered

More information

Adult Echocardiography Examination Content Outline

Adult Echocardiography Examination Content Outline Adult Echocardiography Examination Content Outline (Outline Summary) # Domain Subdomain Percentage 1 2 3 4 5 Anatomy and Physiology Pathology Clinical Care and Safety Measurement Techniques, Maneuvers,

More information

Doppler Basic & Hemodynamic Calculations

Doppler Basic & Hemodynamic Calculations Doppler Basic & Hemodynamic Calculations August 19, 2017 Smonporn Boonyaratavej MD Division of Cardiology, Department of Medicine Chulalongkorn University Cardiac Center, King Chulalongkorn Memorial Hospital

More information

Right Heart Hemodynamics: Echo-Cath Discrepancies

Right Heart Hemodynamics: Echo-Cath Discrepancies Department of cardiac, thoracic and vascular sciences University of Padua, School of Medicine Padua, Italy Right Heart Hemodynamics: Echo-Cath Discrepancies Luigi P. Badano, MD, PhD, FESC, FACC **Dr. Badano

More information

The Doppler Examination. Katie Twomley, MD Wake Forest Baptist Health - Lexington

The Doppler Examination. Katie Twomley, MD Wake Forest Baptist Health - Lexington The Doppler Examination Katie Twomley, MD Wake Forest Baptist Health - Lexington OUTLINE Principles/Physics Use in valvular assessment Aortic stenosis (continuity equation) Aortic regurgitation (pressure

More information

Cardiac Imaging Tests

Cardiac Imaging Tests Cardiac Imaging Tests http://www.medpagetoday.com/upload/2010/11/15/23347.jpg Standard imaging tests include echocardiography, chest x-ray, CT, MRI, and various radionuclide techniques. Standard CT and

More information

HISTORY. Question: How do you interpret the patient s history? CHIEF COMPLAINT: Dyspnea of two days duration. PRESENT ILLNESS: 45-year-old man.

HISTORY. Question: How do you interpret the patient s history? CHIEF COMPLAINT: Dyspnea of two days duration. PRESENT ILLNESS: 45-year-old man. HISTORY 45-year-old man. CHIEF COMPLAINT: Dyspnea of two days duration. PRESENT ILLNESS: His dyspnea began suddenly and has been associated with orthopnea, but no chest pain. For two months he has felt

More information

A NONINVASIVE METHOD FOR CHARACTERIZING VENTRICULAR DIASTOLIC FILLING DYNAMICS

A NONINVASIVE METHOD FOR CHARACTERIZING VENTRICULAR DIASTOLIC FILLING DYNAMICS A NONINVASIVE METHOD FOR CHARACTERIZING VENTRICULAR DIASTOLIC FILLING DYNAMICS R. Mukkamala, R. G. Mark, R. J. Cohen Haard-MIT Division of Health Sciences and Technology, Cambridge, MA, USA Abstract We

More information

Echocardiography Conference

Echocardiography Conference Echocardiography Conference David Stultz, MD Cardiology Fellow, PGY-6 September 20, 2005 Atrial Septal Aneurysm Bulging of Fossa Ovalis Associated commonly with Atrial septal defect or small perforations

More information

SUPPLEMENTAL MATERIAL

SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL Supplemental methods Pericardium In several studies, it has been shown that the pericardium significantly modulates ventricular interaction. 1-4 Since ventricular interaction has

More information

Assessing the Impact on the Right Ventricle

Assessing the Impact on the Right Ventricle Advances in Tricuspid Regurgitation Congress of the European Society of Cardiology (ESC) Munich, August 25-29, 2012 Assessing the Impact on the Right Ventricle Stephan Rosenkranz, MD Clinic III for Internal

More information

PROSTHETIC VALVE BOARD REVIEW

PROSTHETIC VALVE BOARD REVIEW PROSTHETIC VALVE BOARD REVIEW The correct answer D This two chamber view shows a porcine mitral prosthesis with the typical appearance of the struts although the leaflets are not well seen. The valve

More information

UK Biobank. Imaging modality Cardiovascular Magnetic Resonance (CMR) Version th Oct 2015

UK Biobank. Imaging modality Cardiovascular Magnetic Resonance (CMR) Version th Oct 2015 Imaging modality Cardiovascular Magnetic Resonance (CMR) Version 1.0 http://www.ukbiobank.ac.uk/ 30 th Oct 2015 This document details the procedure for the CMR scan performed at an Imaging assessment centre

More information

Rotation: Imaging 2. Nuclear Cardiology (in Imaging 1 and 2)

Rotation: Imaging 2. Nuclear Cardiology (in Imaging 1 and 2) Rotation: Imaging 2 Imaging 2 provides addition nuclear cardiology experience and COCATS Level 1 cardiac MRI experience. Fellows administer, process, and read VHVI cardiac nuclear studies with cardiology

More information

Left atrial function. Aliakbar Arvandi MD

Left atrial function. Aliakbar Arvandi MD In the clinic Left atrial function Abstract The left atrium (LA) is a left posterior cardiac chamber which is located adjacent to the esophagus. It is separated from the right atrium by the inter-atrial

More information

Multiple Gated Acquisition (MUGA) Scanning

Multiple Gated Acquisition (MUGA) Scanning Multiple Gated Acquisition (MUGA) Scanning Dmitry Beyder MPA, CNMT Nuclear Medicine, Radiology Barnes-Jewish Hospital / Washington University St. Louis, MO Disclaimers/Relationships Standard of care research

More information

QUIZ 1. Tuesday, March 2, 2004

QUIZ 1. Tuesday, March 2, 2004 Harvard-MIT Division of Health Sciences and Technology HST.542J: Quantitative Physiology: Organ Transport Systems Instructors: Roger Mark and Jose Venegas MASSACHUSETTS INSTITUTE OF TECHNOLOGY Departments

More information

CARDIAC CYCLE CONTENTS. Divisions of cardiac cycle 11/13/13. Definition. Badri Paudel GMC

CARDIAC CYCLE CONTENTS. Divisions of cardiac cycle 11/13/13. Definition. Badri Paudel GMC CARDIAC CYCLE Badri Paudel GMC CONTENTS Ø DEFINATION Ø DIVISION OF CARDIAC CYCLE Ø SUB DIVISION AND DURATION OF CARDIAC CYCLE Ø SYSTOLE Ø DIASTOLE Ø DESCRIPTION OF EVENTS OF CARDIAC CYCLE Ø SUMMARY Ø ELECTROCARDIOGRAPHY

More information

Evaluation of left ventricular function in patients with chronic obstructive pulmonary disease

Evaluation of left ventricular function in patients with chronic obstructive pulmonary disease Evaluation of left ventricular function in patients with chronic obstructive pulmonary disease Elżbieta Suchoń 1, Wiesława Tracz 1, Piotr Podolec 1, Monika Pieculewicz 1, Wojciech Płazak 1, Anna Prokop

More information

Stephen G. Worthley. Cardiovascular Research Centre, Royal Adelaide Hospital and University of Adelaide, Adelaide, South Australia 5000, Australia

Stephen G. Worthley. Cardiovascular Research Centre, Royal Adelaide Hospital and University of Adelaide, Adelaide, South Australia 5000, Australia RIGHT VENTRICULAR SPECKLE TRACKING STRAIN HAS A CLOSER CORRELATION WITH RIGHT VENTRICULAR EJECTION FRACTION THAN OTHER ECHOCARDIOGRAPHIC INDICES OF RIGHT VENTRICULAR FUNCTION: A COMPARISON WITH CARDIAC

More information

Title:Relation Between E/e' ratio and NT-proBNP Levels in Elderly Patients with Symptomatic Severe Aortic Stenosis

Title:Relation Between E/e' ratio and NT-proBNP Levels in Elderly Patients with Symptomatic Severe Aortic Stenosis Author's response to reviews Title:Relation Between E/e' ratio and NT-proBNP Levels in Elderly Patients with Symptomatic Severe Aortic Stenosis Authors: Mihai Strachinaru (m.strachinaru@erasmusmc.nl) Bas

More information

Titel Kardiologie-SG.ch hot topics in heart failure and mitral regurgitation

Titel Kardiologie-SG.ch hot topics in heart failure and mitral regurgitation Titel Kardiologie-SG.ch hot topics in heart failure and mitral regurgitation where and how to quantify mitral regurgitation: Echolab, Cathlab or MRI? Philipp K. Haager, St. Gallen Measuring mitral regurgitation?

More information

The Cardiac Cycle Clive M. Baumgarten, Ph.D.

The Cardiac Cycle Clive M. Baumgarten, Ph.D. The Cardiac Cycle Clive M. Baumgarten, Ph.D. OBJECTIVES: 1. Describe periods comprising cardiac cycle and events within each period 2. Describe the temporal relationships between pressure, blood flow,

More information

Appendix II: ECHOCARDIOGRAPHY ANALYSIS

Appendix II: ECHOCARDIOGRAPHY ANALYSIS Appendix II: ECHOCARDIOGRAPHY ANALYSIS Two-Dimensional (2D) imaging was performed using the Vivid 7 Advantage cardiovascular ultrasound system (GE Medical Systems, Milwaukee) with a frame rate of 400 frames

More information

Review of Cardiac Imaging Modalities in the Renal Patient. George Youssef

Review of Cardiac Imaging Modalities in the Renal Patient. George Youssef Review of Cardiac Imaging Modalities in the Renal Patient George Youssef ECHO Left ventricular hypertrophy (LVH) assessment Diastolic dysfunction Stress ECHO Cardiac CT angiography Echocardiography - positives

More information

Impedance Cardiography (ICG) Method, Technology and Validity

Impedance Cardiography (ICG) Method, Technology and Validity Method, Technology and Validity Hemodynamic Basics Cardiovascular System Cardiac Output (CO) Mean arterial pressure (MAP) Variable resistance (SVR) Aortic valve Left ventricle Elastic arteries / Aorta

More information

Normal Pericardial Physiology

Normal Pericardial Physiology Normal Pericardial Physiology Normal pericardium contains 20-30 ml of lymphoid fluid lubricating function that facilitates normal myocardial rotation and translation during each cardiac cycle in that the

More information

Καθετηριασμός δεξιάς κοιλίας. Σ. Χατζημιλτιάδης Καθηγητής Καρδιολογίας ΑΠΘ

Καθετηριασμός δεξιάς κοιλίας. Σ. Χατζημιλτιάδης Καθηγητής Καρδιολογίας ΑΠΘ Καθετηριασμός δεξιάς κοιλίας Σ. Χατζημιλτιάδης Καθηγητής Καρδιολογίας ΑΠΘ The increasing interest in pulmonary arterial hypertension (PAH), the increasing interest in implantation of LVADs, and the evolution

More information

AMERICAN IMAGING MANAGEMENT

AMERICAN IMAGING MANAGEMENT 2012 CPT Codes Computerized Tomography (CT) CPT Description Abdomen 74150 CT abdomen; w/o 74160 CT abdomen; with 74170 CT abdomen; w/o followed by Chest 71250 CT thorax; w/o 71260 CT thorax; with 71270

More information

AMERICAN IMAGING MANAGEMENT

AMERICAN IMAGING MANAGEMENT 2010 BCBS of Georgia CPT Codes With Grouper Numbers Computerized Tomography (CT) CPT Description Abdomen 74150 CT abdomen; w/o contrast 6 74160 CT abdomen; with contrast 74170 CT abdomen; w/o contrast

More information

Impaired Regional Myocardial Function Detection Using the Standard Inter-Segmental Integration SINE Wave Curve On Magnetic Resonance Imaging

Impaired Regional Myocardial Function Detection Using the Standard Inter-Segmental Integration SINE Wave Curve On Magnetic Resonance Imaging Original Article Impaired Regional Myocardial Function Detection Using the Standard Inter-Segmental Integration Ngam-Maung B, RT email : chaothawee@yahoo.com Busakol Ngam-Maung, RT 1 Lertlak Chaothawee,

More information

2

2 1 2 Although the term "cardiomyopathy" could theoretically apply to almost any disease affecting the heart, it is usually reserved for "severe myocardial disease leading to heart failure".cardiomyopathy

More information

2019 Qualified Clinical Data Registry (QCDR) Performance Measures

2019 Qualified Clinical Data Registry (QCDR) Performance Measures 2019 Qualified Clinical Data Registry (QCDR) Performance Measures Description: This document contains the 18 performance measures approved by CMS for inclusion in the 2019 Qualified Clinical Data Registry

More information

Evaluation of Left Ventricular Diastolic Dysfunction by Doppler and 2D Speckle-tracking Imaging in Patients with Primary Pulmonary Hypertension

Evaluation of Left Ventricular Diastolic Dysfunction by Doppler and 2D Speckle-tracking Imaging in Patients with Primary Pulmonary Hypertension ESC Congress 2011.No 85975 Evaluation of Left Ventricular Diastolic Dysfunction by Doppler and 2D Speckle-tracking Imaging in Patients with Primary Pulmonary Hypertension Second Department of Internal

More information

ORIGINAL ARTICLE. Takahiro HIGUCHI,*, ** Junichi TAKI,* Kenichi NAKAJIMA,* Seigo KINUYA,* Masatoshi IKEDA,*** Masanobu NAMURA*** and Norihisa TONAMI*

ORIGINAL ARTICLE. Takahiro HIGUCHI,*, ** Junichi TAKI,* Kenichi NAKAJIMA,* Seigo KINUYA,* Masatoshi IKEDA,*** Masanobu NAMURA*** and Norihisa TONAMI* ORIGINAL ARTICLE Annals of Nuclear Medicine Vol. 18, No. 6, 507 511, 2004 Left ventricular ejection and filling rate measurement based on the automatic edge detection method of ECG-gated blood pool single-photon

More information

THE CARDIOVASCULAR SYSTEM

THE CARDIOVASCULAR SYSTEM THE CARDIOVASCULAR SYSTEM AND RESPONSES TO EXERCISE Mr. S. Kelly PSK 4U North Grenville DHS THE HEART: A REVIEW Cardiac muscle = myocardium Heart divided into two sides, 4 chambers (L & R) RS: pulmonary

More information

Go With The Flow: Role of 4D Flow Imaging

Go With The Flow: Role of 4D Flow Imaging 4D Flow Go With The Flow: Role of 4D Flow Imaging Niti R. Aggarwal, MD Associate Director of Cardiac MRI Assistant Professor of Medicine & Radiology University of Wisconsin Madison Disclosures GE Healthcare

More information

Little is known about the degree and time course of

Little is known about the degree and time course of Differential Changes in Regional Right Ventricular Function Before and After a Bilateral Lung Transplantation: An Ultrasonic Strain and Strain Rate Study Virginija Dambrauskaite, MD, Lieven Herbots, MD,

More information

25 different brand names >44 different models Sizes mm

25 different brand names >44 different models Sizes mm Types of Prosthetic Valves BIOLOGIC STENTED Porcine xenograft Pericardial xenograft STENTLESS Porcine xenograft Pericardial xenograft Homograft (allograft) Autograft PERCUTANEOUS MECHANICAL Bileaflet Single

More information

Topics to be Covered. Cardiac Measurements. Distribution of Blood Volume. Distribution of Pulmonary Ventilation & Blood Flow

Topics to be Covered. Cardiac Measurements. Distribution of Blood Volume. Distribution of Pulmonary Ventilation & Blood Flow Topics to be Covered MODULE F HEMODYNAMIC MONITORING Cardiac Output Determinants of Stroke Volume Hemodynamic Measurements Pulmonary Artery Catheterization Control of Blood Pressure Heart Failure Cardiac

More information

CATCH A WAVE.. INTRODUCTION NONINVASIVE HEMODYNAMIC MONITORING 4/12/2018

CATCH A WAVE.. INTRODUCTION NONINVASIVE HEMODYNAMIC MONITORING 4/12/2018 WAVES CATCH A WAVE.. W I S C O N S I N P A R A M E D I C S E M I N A R A P R I L 2 0 1 8 K E R I W Y D N E R K R A U S E R N, C C R N, E M T - P Have you considered that if you don't make waves, nobody

More information

CARDIOVASCULAR PHYSIOLOGY

CARDIOVASCULAR PHYSIOLOGY CARDIOVASCULAR PHYSIOLOGY LECTURE 4 Cardiac cycle Polygram - analysis of cardiac activity Ana-Maria Zagrean MD, PhD The Cardiac Cycle - definitions: the sequence of electrical and mechanical events that

More information

DOPPLER HEMODYNAMICS (1) QUANTIFICATION OF PRESSURE GRADIENTS and INTRACARDIAC PRESSURES

DOPPLER HEMODYNAMICS (1) QUANTIFICATION OF PRESSURE GRADIENTS and INTRACARDIAC PRESSURES THORAXCENTRE DOPPLER HEMODYNAMICS (1) QUANTIFICATION OF PRESSURE GRADIENTS and INTRACARDIAC PRESSURES J. Roelandt DOPPLER HEMODYNAMICS Intracardiac pressures and pressure gradients Volumetric measurement

More information

Advanced imaging of the left atrium - strain, CT, 3D, MRI -

Advanced imaging of the left atrium - strain, CT, 3D, MRI - Advanced imaging of the left atrium - strain, CT, 3D, MRI - Monica Rosca, MD Carol Davila University of Medicine and Pharmacy, Bucharest, Romania Declaration of interest: I have nothing to declare Case

More information

ASCeXAM / ReASCE. Practice Board Exam Questions Monday Morning

ASCeXAM / ReASCE. Practice Board Exam Questions Monday Morning ASCeXAM / ReASCE Practice Board Exam Questions Monday Morning Ultrasound Physics Artifacts Doppler Physics Imaging, Knobology, and Artifacts Echocardiographic Evaluation of the RV Tricuspid and Pulmonary

More information

Qualitative and Quantitative Assessment of Perfusion

Qualitative and Quantitative Assessment of Perfusion APCDE 2011 Qualitative and Quantitative Assessment of Perfusion Hyun Ju Yoon Chonnam National University Hospital Gwangju, Korea ISCHEMIC CASCADE Blood flow mismatch Perfusion defects on nuclear imaging,

More information

Pulmonary Hypertension: Echocardiographic Evaluation of Pulmonary Hypertension and Right Ventricular Function. Irmina Gradus-Pizlo, MD

Pulmonary Hypertension: Echocardiographic Evaluation of Pulmonary Hypertension and Right Ventricular Function. Irmina Gradus-Pizlo, MD Pulmonary Hypertension: Echocardiographic Evaluation of Pulmonary Hypertension and Right Ventricular Function Irmina Gradus-Pizlo, MD Disclosures: Nothing to disclose Overview Is pulmonary hypertension

More information

Certificate in Clinician Performed Ultrasound (CCPU) Syllabus. Rapid Cardiac Echo (RCE)

Certificate in Clinician Performed Ultrasound (CCPU) Syllabus. Rapid Cardiac Echo (RCE) Certificate in Clinician Performed Ultrasound (CCPU) Syllabus Rapid Cardiac Echo (RCE) Purpose: Rapid Cardiac Echocardiography (RCE) This unit is designed to cover the theoretical and practical curriculum

More information

CHF and Pulmonary Edema. Rod Hetherington

CHF and Pulmonary Edema. Rod Hetherington CHF and Pulmonary Edema Rod Hetherington Objectives Given a lecture and group discussion, the paramedic will be able to: Identify and name the key anatomical structures of the heart and vessels Describe

More information

PROBLEM SET 2. Assigned: February 10, 2004 Due: February 19, 2004

PROBLEM SET 2. Assigned: February 10, 2004 Due: February 19, 2004 Harvard-MIT Division of Health Sciences and Technology HST.542J: Quantitative Physiology: Organ Transport Systems Instructors: Roger Mark and Jose Venegas MASSACHUSETTS INSTITUTE OF TECHNOLOGY Departments

More information

THE LEFT ATRIUM HOW CAN ECHO HELP US?

THE LEFT ATRIUM HOW CAN ECHO HELP US? THE LEFT ATRIUM HOW CAN ECHO HELP US? Dr. Dragos COZMA BACKGROUND Left atrium (LA) dilation can occur in a broad spectrum of cardiovascular diseases including hypertension, left ventricular dysfunction,

More information

Diagnostic Imaging Utilization Management and Consultation Management Programs Imaging Code Listing for Connecticut, Maine and New Hampshire

Diagnostic Imaging Utilization Management and Consultation Management Programs Imaging Code Listing for Connecticut, Maine and New Hampshire Diagnostic Imaging Utilization Management and Consultation Management Programs Imaging Code Listing for Connecticut, Maine and New Hampshire The grid below contains the CPT * codes that are subject to

More information

Analysis of Left Ventricular Function

Analysis of Left Ventricular Function Analysis of Left Ventricular Function from Multiple Gated Acquisition Cardiac Blood Pool Imaging Comparison to Contrast Angiography ROBERT D. BUROW, B.S., H. WILLIAM STRAUSS, M.D., Ross SINGLETON, PH.D.,

More information

Determination of Stroke Volume from Left Ventricular Isovolumetric Contraction and Ejection Times

Determination of Stroke Volume from Left Ventricular Isovolumetric Contraction and Ejection Times Determination of Stroke Volume from Left Ventricular Isovolumetric Contraction and Ejection Times Clarence M. AGRESS, M.D. and Stanley WEGNER SUMMARY Examination was made of the relationship of left ventricular

More information

Previous talks. Clinical applications for spiral flow imaging. Clinical applications. Clinical applications. Coronary flow: Motivation

Previous talks. Clinical applications for spiral flow imaging. Clinical applications. Clinical applications. Coronary flow: Motivation for spiral flow imaging Joao L. A. Carvalho Previous talks Non-Cartesian reconstruction (2005) Spiral FVE (Spring 2006) Aortic flow Carotid flow Accelerated spiral FVE (Fall 2006) 2007? Department of Electrical

More information

doi: /j.jacc This information is current as of February 11, 2008

doi: /j.jacc This information is current as of February 11, 2008 Interventricular Mechanical Asynchrony in Pulmonary Arterial Hypertension: Left-to-Right Delay in Peak Shortening Is Related to Right Ventricular Overload and Left Ventricular Underfilling J. Tim Marcus,

More information

Pathophysiology: Left To Right Shunts

Pathophysiology: Left To Right Shunts Pathophysiology: Left To Right Shunts Daphne T. Hsu, MD dh17@columbia.edu Learning Objectives Learn the relationships between pressure, blood flow, and resistance Review the transition from fetal to mature

More information

Cath Lab Essentials: Basic Hemodynamics for the Cath Lab and ICU

Cath Lab Essentials: Basic Hemodynamics for the Cath Lab and ICU Cath Lab Essentials: Basic Hemodynamics for the Cath Lab and ICU Ailin Barseghian El-Farra, MD, FACC Assistant Professor, Interventional Cardiology University of California, Irvine Department of Cardiology

More information

CARDIAC MRI. Cardiovascular Disease. Cardiovascular Disease. Cardiovascular Disease. Overview

CARDIAC MRI. Cardiovascular Disease. Cardiovascular Disease. Cardiovascular Disease. Overview CARDIAC MRI Dr Yang Faridah A. Aziz Department of Biomedical Imaging University of Malaya Medical Centre Cardiovascular Disease Diseases of the circulatory system, also called cardiovascular disease (CVD),

More information

Case Report Sinus Venosus Atrial Septal Defect as a Cause of Palpitations and Dyspnea in an Adult: A Diagnostic Imaging Challenge

Case Report Sinus Venosus Atrial Septal Defect as a Cause of Palpitations and Dyspnea in an Adult: A Diagnostic Imaging Challenge Case Reports in Medicine Volume 2015, Article ID 128462, 4 pages http://dx.doi.org/10.1155/2015/128462 Case Report Sinus Venosus Atrial Septal Defect as a Cause of Palpitations and Dyspnea in an Adult:

More information

가천의대길병원소아심장과최덕영 PA C IVS THE EVALUATION AND PRINCIPLES OF TREATMENT STRATEGY

가천의대길병원소아심장과최덕영 PA C IVS THE EVALUATION AND PRINCIPLES OF TREATMENT STRATEGY 가천의대길병원소아심장과최덕영 PA C IVS THE EVALUATION AND PRINCIPLES OF TREATMENT STRATEGY PA c IVS (not only pulmonary valve disease) Edwards JE. Pathologic Alteration of the right heart. In: Konstam MA, Isner M, eds.

More information

Cardiovascular Structure & Function

Cardiovascular Structure & Function Cardiovascular Structure & Function Cardiovascular system: The heart Arteries Veins Capillaries Lymphatic vessels Weighting of the heart ceremony: Ancient Egyptians William Harvey and Blood Flow April

More information

Objectives 8/17/2011. Challenges in Cardiac Imaging. Challenges in Cardiac Imaging. Basic Cardiac MRI Sequences

Objectives 8/17/2011. Challenges in Cardiac Imaging. Challenges in Cardiac Imaging. Basic Cardiac MRI Sequences 8/17/2011 Traditional Protocol Model for Tomographic Imaging Cardiac MRI Sequences and Protocols Frandics Chan, M.D., Ph.D. Stanford University Medical Center Interpretation Lucile Packard Children s Hospital

More information

left atrial myxoma causes paradoxical motion of the catheter; posterior

left atrial myxoma causes paradoxical motion of the catheter; posterior Am JRoentgenolla6:II55-II58, 1976 ABNORMAL LEFT VENTRICULAR CATHETER MOTION: AN ANCILLARY ANGIOGRAPHIC SIGN OF LEFT ATRIAL MYXOMA ABsTRACT: J. M. RAU5CH, R. T. REINKE, K. L. PETERSON,2 AND C. B. HIGGINs

More information

End of chapter exercises

End of chapter exercises End of chapter exercises Problem 1: The following diagrams show the heart during the cardiac cycle. The arrows represent the flow of blood. Study the diagrams and answer the questions that follow: Figure

More information

PHYSIOLOGY MeQ'S (Morgan) All the following statements related to blood volume are correct except for: 5 A. Blood volume is about 5 litres. B.

PHYSIOLOGY MeQ'S (Morgan) All the following statements related to blood volume are correct except for: 5 A. Blood volume is about 5 litres. B. PHYSIOLOGY MeQ'S (Morgan) Chapter 5 All the following statements related to capillary Starling's forces are correct except for: 1 A. Hydrostatic pressure at arterial end is greater than at venous end.

More information

Imaging in Heart Failure: A Multimodality Approach. Thomas Ryan, MD

Imaging in Heart Failure: A Multimodality Approach. Thomas Ryan, MD Imaging in Heart Failure: A Multimodality Approach Thomas Ryan, MD Heart Failure HFrEF HFpEF EF50% Lifetime risk 20% Prevalence 6M Americans Societal costs - $30B 50% 5-year survival 1 Systolic

More information

Interventricular Mechanical Asynchrony in Pulmonary Arterial Hypertension

Interventricular Mechanical Asynchrony in Pulmonary Arterial Hypertension Journal of the American College of Cardiology Vol. 51, No. 7, 2008 2008 by the American College of Cardiology Foundation ISSN 0735-1097/08/$34.00 Published by Elsevier Inc. doi:10.1016/j.jacc.2007.10.041

More information

Pathophysiology: Left To Right Shunts

Pathophysiology: Left To Right Shunts Pathophysiology: Left To Right Shunts Daphne T. Hsu, MD dh17@columbia.edu Learning Objectives Learn the relationships between pressure, blood flow, and resistance Review the transition from fetal to mature

More information

The Patient with Atrial Fibrilation

The Patient with Atrial Fibrilation Assessment of Diastolic Function The Patient with Atrial Fibrilation Assoc. Prof. Adriana Ilieşiu, FESC University of Medicine Carol Davila Bucharest, Romania Associated Conditions with Atrial Fibrillation

More information

How to assess ischaemic MR?

How to assess ischaemic MR? ESC 2012 How to assess ischaemic MR? Luc A. Pierard, MD, PhD, FESC, FACC Professor of Medicine Head, Department of Cardiology University Hospital Sart Tilman, Liège ESC 2012 No conflict of interest Luc

More information

Screening for CETPH after acute pulmonary embolism: is it needed? Menno V. Huisman Department of Vascular Medicine LUMC Leiden

Screening for CETPH after acute pulmonary embolism: is it needed? Menno V. Huisman Department of Vascular Medicine LUMC Leiden Screening for CETPH after acute pulmonary embolism: is it needed? Menno V. Huisman Department of Vascular Medicine LUMC Leiden m.v.huisman@lumc.nl Background CETPH Chronic Thrombo Embolic Pulmonary Hypertension

More information

A Magnetic Resonance Imaging Method for

A Magnetic Resonance Imaging Method for Journal of Cardiovascular Magnetic Resonance, 1(1), 59-64 (1999) INVITED PAPER Use of MRI in ASD Asessment A Magnetic Resonance Imaging Method for Evaluating Atrial Septa1 Defects Godtfred Holmvang Cardiac

More information

Atrioventricular Valve Dysplasia

Atrioventricular Valve Dysplasia Atrioventricular Valve Dysplasia How does the heart work? The heart is the organ responsible for pumping blood to and from all tissues of the body. The heart is divided into right and left sides. The job

More information

QCVC Committees Scientific Activities Central Hall General Information FAC. SPECT tomography has the advantage of quantifying biventricular volumes.

QCVC Committees Scientific Activities Central Hall General Information FAC. SPECT tomography has the advantage of quantifying biventricular volumes. QCVC Committees Scientific Activities Central Hall General Information FAC Thematic Units Arrhythmias and Electrophysiology Basic Research Bioengineering and Medical Informatics Cardiac Surgical Intensive

More information

Hemodynamic Monitoring

Hemodynamic Monitoring Perform Procedure And Interpret Results Hemodynamic Monitoring Tracheal Tube Cuff Pressure Dean R. Hess PhD RRT FAARC Hemodynamic Monitoring Cardiac Rate and Rhythm Arterial Blood Pressure Central Venous

More information

Syncope Due to Intracavitary Left Ventricular Obstruction Secondary to Giant Esophageal Hiatus Hernia

Syncope Due to Intracavitary Left Ventricular Obstruction Secondary to Giant Esophageal Hiatus Hernia American Journal of Medical Case Reports, 2017, Vol. 5, No. 4, 89-93 Available online at http://pubs.sciepub.com/ajmcr/5/4/4 Science and Education Publishing DOI:10.12691/ajmcr-5-4-4 Syncope Due to Intracavitary

More information

Diagnostic approach to heart disease

Diagnostic approach to heart disease Diagnostic approach to heart disease Initial work up History Physical exam Chest radiographs ECG Special studies Echocardiography Cardiac catheterization Echocardiography principles Technique of producing

More information

MUGA Scan. A Patient s Guide. Copyrighted Material. HeartWise Patient Education

MUGA Scan. A Patient s Guide. Copyrighted Material. HeartWise Patient Education MUGA Scan Copyrighted Material HeartWise Patient Education 800-747-1606 A Patient s Guide What Is a MUGA Scan? A multiple gated acquisition (or MUGA) scan is a test that uses a radioactive substance, called

More information

Pulmonary hypertension

Pulmonary hypertension Zurich Open Repository and Archive University of Zurich Main Library Strickhofstrasse 39 CH-8057 Zurich www.zora.uzh.ch Year: 2012 Pulmonary hypertension Glaus, T M Posted at the Zurich Open Repository

More information