Systems for Below the Knee Interventions

Size: px
Start display at page:

Download "Systems for Below the Knee Interventions"

Transcription

1 VCULR THERPIE rterial Venous Neurovascular ystems for Below the Knee Interventions Nitrex Guidewire TrailBlazer upport Catheter Viance Crossing Catheter Enteer Re-entry ystem TurboHawk Plaque Excision ystem NanoCross Elite.0 OTW PT Balloon Catheter PowerCross.01 OTW PT Balloon Catheter RapidCross.0 Rapid Exchange PT Balloon Dilatation Catheter mplatz GooseNeck nare and Microsnare

2 NitrexTM Guidewires Nitinol Technology Designed for High Performance. The Nitrex TM guidewire s superelastic nitinol core extends from proximal to distal tip to provide an atraumatic wire solution for Below the Knee vessels with your choice of 0.0" and sizes. KINK REITNCE COIL DHEIVE Gently tapered, continuous nitinol core extends from tip to tip, providing flexibility and kink resistance TIP UPERELTIC NITINOL CORE GOOD RDIOPCITY Gold tungsten coiling enhances radiopacity for fluoroscopic visualization TRUE 1:1 TORQUE Nitrex nitinol guidewires feature true 1:1 torque on your choice of a stiff or flexible shaft, with standard, intermediate and floppy tips PRE-HPED TIP traight 1

3 TrailBlazerTM upport Catheter Crossing Boundaries. Expanding Options. TrailBlazer TM support catheter is designed to provide support and increased pushability in difficult Below the Knee lesions. INCREED PUHBILITY 1 CrossCoat hydrophilic coating on distal 0 cm creates smooth tracking through challenging vasculature LUBRICIOU INNER LYER ROBUT OUTER LYER GUIDEWIRE LUMEN Robust catheter outer provides robust pushability Lubricious catheter inner enables smooth guidewire movement OPTIMIZED VIIBILITY Three embedded marker bands aid visibility with seamless catheter advancement TPERED, LOW PROFILE TIP FOR EE OF LEION ENTRY Rounded tip provides ultra smooth transition to wire Increases pushability without sacrificing profile 1 Covidien Internal testing CRD

4 VianceTM Crossing Catheter Finesse over Force. The Viance TM crossing catheter is designed to quickly and safely deliver a guidewire via true lumen or subintimal path. UME CONTROL Tracks via fast spin technique: traumatic tip reduces chance for perforation Highly torqueable coiled-wire shaft Fast spin reduces push required to cross lesion FIND YOUR WY Multi-wired coil shaft traumatic distal tip advanced ahead of guidewire VINCE DITL TIP VINCE CTHETER HFT COMPTIBILITY No capital equipment required OTW 0.0 guidewire compatible 0.0 crossing profile Multi-wire coiled shaft delivers 1:1 torque Handle enables fast-spin technique Ratchet limits torque output if too much resistance is built up

5 EnteerTM Re-entry ystem Intuitive Design. The Enteer TM re-entry system is designed to easily self-orient and reliably target the true lumen above and below the knee. THE ENTEER RE-ENTRY YTEM CONIT OF: DITL TIP The Enteer re-entry catheter elf-orienting balloon has a flat shape for true lumen targeting 1 opposed and offset exit ports for selective guidewire re-entry ENTEER RE-ENTRY GUIDEWIRE The Enteer guidewire Re-entry probe at guidewire tip DITL PORT PROXIML PORT 1 opposed MRKER BND vailable in Flexible, tandard and tiff COMPTIBILITY No capital equipment required OTW 0.0 and 0.01 guidewire compatible

6 TurboHawkTM Plaque Excision ystem for mall Vessels Preserve Treatment Options. Remove the plaque. Maximize lumen gain. Minimize barotrauma. OPTIMIZED TIUE COLLECTION ND CPCITY (COMPRED TO PREDICTE DEVICE) MEC (Micro Efficient Compression) technology provides tiny laser drilled holes in the nosecone, releasing fluid and maximizing tissue collection compacity, potentially resulting in fewer insertions and reduced overall procedure time MEC (MICRO EFFICIENT COMPREION) TECHNOLOGY

7 CUTTING PRECIION angled cutter blades added for high efficiency cutter performance Innovative cutter design addresses all plaque morphologies including moderately to severe calcified lesions CONITENT PERFORMNCE IN WIDE RNGE OF VEEL Dual catheter jog ensures consistent cutter contact, enabling effective tissue engagement in vessels mm in diameter Jog design controls maximum apposition force in smaller vessel diameters and provides improved cutter apposition as vessel diameters increase during treatment

8 NanoCrossTM Elite.0 OTW PT Balloon Catheter Push Treatment Further. The NanoCross TM Elite balloon catheter has the pushability to take you deep into the anatomy and across difficult lesions. LOW TIP ENTRY PROFILE Enables successful crossing of tandem lesions TIGHTER PLET FOLD Reduces the crossing profile for easier access to smaller, tighter, more distal regions MOOTH, TPERED TIP Offers control to easily navigate turns and tortuosity ROBUT HFT DEIGN For buckle-resistant pushability and delivery across the length of the catheter TPERED LONG BLLOON Tailored for distal and pedal anatomy Tapered balloon available on 10 mm balloon length

9 PowerCrossTM.01 OTW PT Balloon Catheter Experience The Power. The PowerCross TM 0.01 balloon catheter is an over-the-wire balloon designed to treat distal lesions with refined pushability. ULTR-LOW CROING PROFILE trength and crossiblity designed into ThermoFlex balloon material mooth transition from tip to wire with Bevel Tip IMPROVED DELIVERBILITY 1 Optimized pushability and tracking with robust catheter shaft 1 TY ORIENTED Long length NanoCross and PowerCross balloons feature DUL MIDDLE MRKER BND to facilitate visualization and orientation during high magnification fluoroscopy..0 CROING PROFILE PREFERRED Covidien PowerCross TM xx10 Boston terling TM * xx1 Invatec Pacific Extreme TM * x10x10 Cordis avvy TM * xx10 Cordis avvy Long TM * x0x10 Invatec ubmarine Plus TM * x10x10 1 Internal PT OTW Competitive Testing no. RE-PV10.

10 RapidCrossTM.0 Rapid Exchange PT Balloon Dilatation Catheter Treat Tighter and More Distal Lesions. Finally, an RX balloon engineered for below the knee the RapidCross TM catheter was exclusively developed for peripheral anatomies and thoughtfully designed for exceptional performance. CRO ND TRET EVEN THE TIGHTET LEION Low profile for ease in crossing Dual middle marker bands, available on 10 mm and 10 mm balloon lengths, for enhanced visualization and accuracy Proprietary balloon coating ensures sustained lubricity for crossing challenging lesions KINK-REITNT PUHBILITY TO WITHTND TORTUOITY Maximum inner lumen diameter for faster deflation Tapered long balloon tailored to distal tibial and pedal anatomy In-line proximal wire exit port and alloy support wire to reduce kinking LONG LENGTH FOR IMPROVED DITL CCE OVER HORT HFT 170 cm length enables distal access to BTK lesions cm RX port length

11 mplatz Goose NeckTM nare and Microsnare Pulling You Through. Easy guidewire pull-through in retrograde pedal artery access with Goose Neck TM snares and microsnares. ENHNCED VIULIZTION Gold tungsten for excellent radiopacity under fluoroscopy TRUE 9 NRE LOOP True 9 snare loop remains coaxial to the lumen for easier wire capture Images courtesy of Dr. ndrej chmidt, Parkkrankenhaus Leipzig, Germany

12 Nitrex TM Guidewires Product Number Diameter (in) Length (cm) Tip tyle Tip Length (cm) Tip hape Tip ngle 0.0" N01 N1 0.0" 0.0" N " 00 1 N11 N1 7 N11 TD N1 N1 1 TD 1 N N11 1 FLOP 0 1 N1 00 TD N " N11 N1 0.0" 0.0" 1 1 TD 1 N1 0.0" 1 N1 0.0" 1 0.0" Flexible haft N N1 N1 0.0" 0.0" 0.0" N " 00 1 N01 0.0" 9 N 0.0" FLOP N 0.0" 9 N 0.0" FLOP 0.0" tiff haft N N1 N 0.0" 0.0" 0.0" 1 1 TD FLOP 9 N 0.0" TD N 0.0" 9 N " 00 9 N00 0.0" 00 9 TIP HPE: = ngled Tip; = traight Tip; TIP TYLE: = Intermediate Tip; TD = tandard Tip; FLOP = Floppy Tip pecifications Nominal. Nitrex TM products are sold /box; Babywire TM products are sold 10/box. Torque device included on 0.0" and Nitrex TM guidewires. Baby Wire TM Double-Ended Guidewires Product Number BW BW101 Diameter (in) 0.01" 0.01" Length (cm) 1 0 TrailBlazer TM upport Catheter Minimum Guide Catheter (Fr) Minimum Introducer heath (Fr) Marker pace (mm) cm (Product #) 90 cm (Product #) 1 cm (Product #) 10 cm (Product #) CROING PROFILE Distal Crossing Profile (Fr) Proximal Crossing Profile (Fr) 0.0" 1 C-0-1 C-0-10,0,0 1 C C-01-1 C-01-10,, 0.0" 0 C-0-0 C C-0-1 C-0-10,, Viance TM Crossing Catheter Product Number Feature Working Length (cm) Crossing Profile (in) Distal Coating Length / Material heath Compatibility (Fr) VNC-FX-10 Flexible cm / Hydrophilic VNC-D-10 tandard cm / Hydrophilic Enteer TM Re-entry Catheter Product Number natomy Crossing Profile (in) Balloon Dimensions width x height x length (mm) Working Length (cm) Guidewire Compatibility (in) heath Compatibility (Fr) ENB BTK x 1.0 x ENB TK x 1. x

13 Enteer TM Guidewire Product Number Feature Diameter (in) Length (cm) Distal Coating Tip ngle Tip Reach (mm) ENW-FX-0-00 Flexible Hydrophilic 1. ENW-D-0-00 tandard Hydrophilic 1. ENW-F-0-00 tiff Hydrophilic. TurboHawk TM Plaque Excision ystem for mall Vessels Product Number Vessel Diameter (mm) heath Compatibility 1 (F) Crossing Profile (in / mm) Working Length (cm) Effective Length (cm) Tip Length (cm) Max. Cut Length (mm) X-C mall Vessel Extended Calcium Tip TH-X-C / C mall Vessel tandard Calcium Tip TH--C / CL mall Vessel tandard Calcium Tip Long Catheter TH--CL / Max guidewire is 0.0 for all TurboHawk devices. 1 heath Compatibility Per the Instructions For Use. Data on file with manufacturer. Working Length distal end of strain relief to the distal end of tip. Packing Device vs. MEC TM Tech X-C: mall Vessel Extended Calcium Tip -C: mall Vessel tandard Calcium Tip Packing Device X MEC TM Tech X X Effective Length distal end of strain relief to the proximal end of cutter window. -CL: mall Vessel tandard Calcium Tip Long Catheter X mplatz Goose Neck TM nare and Microsnare Product Number Loop Diameter (mm) nare Length (cm) Catheter ize (Fr) Catheter Length (cm) mplatz Goose Neck TM nare Kit GN00 GN0 GN1 GN GN KIT INCLUDE: - nare - nare Catheter GN00 GN01 GN GN Microsnare KIT INCLUDE: - nare - Microcatheter K00 K01 K00 K01 K700 K Product Number Catheter ize (Fr) Catheter Length (cm) nare Replacement Catheters pecifications Nominal. MC000 MC001 MC00 MC

14 NanoCross TM Elite.0 OTW PT Balloon Catheter Catheter Length 90 cm Catheter Length 10 cm Balloon Diameter (mm) Balloon Length (mm) RapidCross TM PT Balloon Dilatation Catheter Catheter Length 90 cm Catheter Length 170 cm Balloon Diameter (mm) Balloon Length (mm) BW0090 BW BX BX BW0090 BW BX BX BW BW BX BX BW BW BX BX BW BW BX00090 BX BW BW BX0090 BX BW00090 BW BX0090 BX BW0090 BW BX0090 BX (proximal) / 1. (distal) 10 BW0090 BW BX BX BW0090 BW (proximal) / 1. (distal) 10 BX BX BW BW BX00090 BX BW BW BX00090 BX BW00090 BW0010. BX0090 BX0170. BW00090 BW0010. BX090 BX BW0090 BW010. BX090 BX BW090 BW BX090 BX (proximal) /.0 (distal) 10 BW090 BW BX BX BW090 BW (proximal) /.0 (distal) 10 BX BX BW BW BX BX BW BW BX BX BW BW BX00090 BX BW BW BX0090 BX BW00090 BW BX0090 BX BW0090 BW BX0090 BX (proximal) /. (distal) 10 BW0090 BW BX BX BW0090 BW (proximal) /. (distal) 10 BX BX BW BW BX00090 BX BW BW BX00090 BX BW00090 BW0010. BX0090 BX0170. BW00090 BW0010. BX090 BX BW0090 BW010. BX090 BX BW090 BW BX090 BX (proximal) /.0 (distal) 10 BW090 BW BX BX BW090 BW (proximal) /.0 (distal) 10 BX BX BW BW BX BX BW BW BX BX BW BW BX00090 BX BW BW BX0090 BX BW00090 BW0090 BW0090 BW0090 BW0010 BW BW BW (proximal) /. (distal) Recommended Introducer heath for all NanoCross Elite = (Fr) Nominal Pressure for all NanoCross Elite = (atm) Rated Burst Pressure for all NanoCross Elite = (atm) BX0090 BX0090 BX BX (proximal) /. (distal) Recommended Introducer heath for all RapidCross = (Fr) Nominal Pressure for all RapidCross = (atm) Rated Burst Pressure for all RapidCross = (atm) 10 10

15 PowerCross TM.01 PT Balloon Balloon Diameter (mm) Catheter Length 90 cm Catheter Length 10 cm Balloon Length (mm) Nominal Pressure (atm) Rated Burst Pressure (atm) Recommended Introducer heath (Fr) B1W B1W B1W00090 B1W0090 B1W B1W B1W B1W0090 B1W090 B1W B1W B1W B1W B1W B1W00090 B1W0090 B1W0090 B1W B1W B1W B1W B1W B1W00090 B1W0090 B1W0090 B1W B1W B1W B1W B1W B1W00090 B1W0090 B1W0090 B1W B1W B1W B1W00090 B1W00090 B1W0090 B1W090 B1W090 B1W B1W B1W B1W0010 B1W B1W B1W00010 B1W00010 B1W010 B1W01010 B1W00010 B1W B1W B1W00010 B1W00010 B1W0010 B1W B1W B1W B1W B1W B1W00010 B1W00010 B1W0010 B1W B1W B1W B1W B1W B1W00010 B1W00010 B1W0010 B1W B1W B1W B1W00010 B1W00010 B1W0010 B1W0010 B1W010 B1W01010 B1W01010 B1W

16 IMPORTNT: Please refer to the package insert for complete instructions, contraindications, warnings and precautions. COVIDIEN, COVIDIEN with logo, Covidien logo and positive results for life are U and internationally registered trademarks of Covidien G. * Trademark of its respective owner. Other brands are trademarks of a Covidien company. 0 Covidien () MR/1 Intl. EU To contact us, please visit and select contact us Use scan app to read

SFA Solutions VASCULAR THERAPIES. Arterial Venous Neurovascular. Wholey Guidewire System. Nitrex Guidewires. TrailBlazer Support Catheter

SFA Solutions VASCULAR THERAPIES. Arterial Venous Neurovascular. Wholey Guidewire System. Nitrex Guidewires. TrailBlazer Support Catheter VCULR THERPIE rterial Venous Neurovascular F olutions Wholey Guidewire ystem Nitrex Guidewires TrailBlazer upport Catheter Viance Crossing Catheter Enteer Re-entry ystem TurboHawk Plaque Excision ystem

More information

Iliac Solutions. Arterial Venous Neurovascular. Wholey Guidewire System. Nitrex Guidewires. TrailBlazer Support Catheter

Iliac Solutions. Arterial Venous Neurovascular. Wholey Guidewire System. Nitrex Guidewires. TrailBlazer Support Catheter VCULR THERPIE rterial Venous Neurovascular Iliac olutions Wholey Guidewire ystem Nitrex Guidewires TrailBlazer upport Catheter EverCross.03 OTW PT Balloon Catheter VisiPro Balloon Expandable tent Protege

More information

TurboHawk. Plaque Excision System

TurboHawk. Plaque Excision System TurboHawk Plaque Excision System Twelve-month Patency in Diabetics DIABETICS VS. NON-DIABETICS 12-month Primary Patency (%) Diabetic patients show a more positive response to directional atherectomy than

More information

PERIPHERAL US PRODUCT

PERIPHERAL US PRODUCT PERIPHERAL US PRODUCT CATALOG July 2017 1 TABLE OF CONTENTS DIRECTIONAL ATHERECTOMY SYSTEMS HawkOne Directional Atherectomy System --------------------------------------------------------------------------------------------

More information

MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES

MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES PUSHING BOUNDARIES Terumo Interventional Systems is committed to your success with innovative procedural solutions and ongoing support for your most challenging

More information

Chronic Total Occlusion (CTO) Technologies

Chronic Total Occlusion (CTO) Technologies to receive our latest news and key activities. Chronic Total Occlusion (CTO) Technologies Re-open vital channels LinkedIn page Follow us on CORDIS EMEA OUTBACK LTD Re-Entry Catheter True Lumen Re-Entry

More information

Advanced Innovation for Exceptional Performance

Advanced Innovation for Exceptional Performance Advanced Innovation for Exceptional Performance longest BALLOON LENGTHS ON THE MARKET Bard Peripheral Vascular Ultraverse 014 300 mm Boston Scientific Coyote 220 mm Cordis SLEEK RX 220 mm Aviator Plus

More information

The Art of. Flow Restoration. Ikazuchi Zero. Semi-Compliant PTCA Balloon OVERVIEW CROSSABILITY LOW PROFILE CASE STUDY CODES

The Art of. Flow Restoration. Ikazuchi Zero. Semi-Compliant PTCA Balloon OVERVIEW CROSSABILITY LOW PROFILE CASE STUDY CODES The Art of Flow Restoration Japan s Recognized PCI Technology For Both Everyday and Complex CTO Cases* Manufactured by Kaneka Corporation, one of Japan s leading providers of interventional devices. Now

More information

SMOOTH VASCULAR ACCESS COMPARATIVE BENCH TOP RESULTS

SMOOTH VASCULAR ACCESS COMPARATIVE BENCH TOP RESULTS SMOOTH VASCULAR ACCESS COMPARATIVE BENCH TOP RESULTS A NEW STANDARD FOR SMOOTH VASCULAR ACCESS NEEDLE PENETRATION FORCE Needle penetration was measured by the amount of force it took for the needle to

More information

NIRxcell CoCr Coronary Stent System

NIRxcell CoCr Coronary Stent System cordis.com/nirxcell NIRxcell CoCr Coronary Stent System Exceptional Outcomes by Design Exceptionally low TLR rate of 5.1 % at 9 months 1 Superior Deliverability and Crossability 2 Best-in-class Conformability

More information

Phoenix Atherectomy System Product Overview /LB

Phoenix Atherectomy System Product Overview /LB Phoenix Atherectomy System Product Overview Phoenix Atherectomy System- The next generation of atherectomy The first hybrid atherectomy system available Combines the benefits of existing atherectomy systems

More information

Penumbra INTRACRANIAL ACCESS REDEFINED

Penumbra INTRACRANIAL ACCESS REDEFINED Penumbra INTRACRANIAL ACCESS REDEFINED BENCHMARK Case Examples Stability & Compatibility Atraumatic Navigation Flow Diverter Delivery Pipeline BENCHMARK Stability Without Surpass Full distal shaft radiopacity

More information

Chronic Total Occlusion (CTO) Technologies. Re-open vital channels

Chronic Total Occlusion (CTO) Technologies. Re-open vital channels Chronic Total Occlusion (CTO) Technologies Re-open vital channels OUTBACK LTD Re-Entry Catheter True Lumen Re-Entry Technology Get back into the true lumen with ease and precision There are a number of

More information

Guide Wires design and selection Abbott Vascular. All rights reserved.

Guide Wires design and selection Abbott Vascular. All rights reserved. Guide Wires design and selection the cardiac catheter was...the key in the lock Cournand AF, Nobel lecture December 11, 1956; nowadays, the coronary guidewire is the master key to all locks Colombo et

More information

CTO: Technique and Tools

CTO: Technique and Tools CTO: Technique and Tools S. Hinan Ahmed, MD Associate Professor: Cardiology and Cardiothoracic Surgery Program Director: Interventional Fellowship Program Associate Editor: Cath Cardiov Interventions UT

More information

NAVIGATE DISTAL AND TORTUOUS ANATOMY

NAVIGATE DISTAL AND TORTUOUS ANATOMY PROGREAT ALPHA PUSHINGBOUNDARIES Terumo Interventional Systems is committed to your success with innovative procedural solutions and ongoing support for your most challenging cases. We are relentlessly

More information

Guidewire Selection. Making the Most Out of My Guidewire: LINC 2016: Leipzig Interventional Course Leipzig, Germany January 26-29, 2016

Guidewire Selection. Making the Most Out of My Guidewire: LINC 2016: Leipzig Interventional Course Leipzig, Germany January 26-29, 2016 Making the Most Out of My Guidewire: Guidewire Selection LINC 2016: Leipzig Interventional Course Leipzig, Germany January 26-29, 2016 Brian DeRubertis, MD, FACS Associate Professor of Surgery Division

More information

Navigate Complex Interventions at Every Turn

Navigate Complex Interventions at Every Turn Navigate Complex Interventions at Every Turn Keep Driving Forward The portfolio of Catheters places the power in your hands. Navigate tortuous anatomy with agility and precision. No matter the challenge,

More information

My idea on intimal tracking guide wire selection for Pop-BTK treatment

My idea on intimal tracking guide wire selection for Pop-BTK treatment LINC 2017 Leipzig January 24-27, 2017 My idea on intimal tracking guide wire selection for Pop-BTK treatment Jos C. van den Berg, MD PhD Ospedale Regionale di Lugano, sede Civico Lugano University of Bern

More information

Solitaire FR Revascularization Device

Solitaire FR Revascularization Device Solitaire FR Revascularization Device FEATURING PARAMETRIC DESIGN Restore. Retrieve. Revive. 5 Revolutionizing Mechanical Thrombectomy with Parametric Design Solitaire FR Device The Solitaire FR revascularization

More information

JETSTREAM Atherectomy System DELIVERING VERSATILITY TO RESTORE FLOW

JETSTREAM Atherectomy System DELIVERING VERSATILITY TO RESTORE FLOW JETSTREAM Atherectomy System DELIVERING VERSATILITY TO RESTORE FLOW DISCOVER THE VALUE OF VERSATILITY Versatility means not having to guess the morphology! Peripheral arterial lesions can present with

More information

We Catch. What Others Miss

We Catch. What Others Miss We Catch What Others Miss GORE Embolic Filter Diamond Frame Circumferential Filter Attachment eptfe Filter Media with 100-Micron Pores and Hydrophilic Heparin Coating Diamond Frame designed to enhance

More information

New Devices Pedro Pinto Cardoso

New Devices Pedro Pinto Cardoso New Devices Pedro Pinto Cardoso HSM, CHLN, CALM for CTOs Guidewires Microcatheters Radiofrequency Pharmacotherapy Pedro Pinto Cardoso, Serviço de Cardiologia HSM CHLN New Guidewires SENTAI family Samurai

More information

HLS Cannulae Solutions from tip to tip.

HLS Cannulae Solutions from tip to tip. HLS Cannulae Solutions from tip to tip. This document is intended to provide information to an international audience outside of the US. 5 HLS cannulae HLS Cannulae Vessels access becomes easier. Maquet

More information

HLS Cannulae Solutions from tip to tip.

HLS Cannulae Solutions from tip to tip. HLS Cannulae Solutions from tip to tip. This document is intended to provide information to an international audience outside of the US. 3 HLS cannulae Standard for single lumen cannulation. Smooth transition

More information

Combine the best of both worlds

Combine the best of both worlds S c i e n c e B a s e d E v o l u t i o n s l e a d t o R e v o l u t i o n a r y S o l u t i o n s PIONEER CoCr STENT ON DEB Combine the best of both worlds A next step in cardiovascular treatment should

More information

Antegrade techniques for CTO recanalization. Dr. George Karavolias, MD, PhD, FESC, FACC Interventional Cardiologist

Antegrade techniques for CTO recanalization. Dr. George Karavolias, MD, PhD, FESC, FACC Interventional Cardiologist Antegrade techniques for CTO recanalization Dr. George Karavolias, MD, PhD, FESC, FACC Interventional Cardiologist can CTOs be reliably opened by PCI? Meta-Analysis of 18,061 Patients Patel V, J Am Coll

More information

Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family

Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family MICRO-INTRODUCERS Micro-Introducer Kits Galt s Micro-Introducer Kits with smooth transition,

More information

Ultrasound User Demonstration

Ultrasound User Demonstration Ultrasound User Demonstration Disclaimer: This presentation is intended to be used as a demonstration educational device to showcase Terumo products. It is NOT intended to be used as a diagnostic device

More information

Access More Patients. Customize Each Seal.

Access More Patients. Customize Each Seal. Access More. Customize Each Seal. The Least Invasive Path Towards Proven Patency ULTRA LOW PROFILE TO EASE ADVANCEMENT The flexible, ultra-low 12F ID Ovation ix delivery system enables you to navigate

More information

Ruby Coil. Large Volume Detachable Coils

Ruby Coil. Large Volume Detachable Coils Ruby Coil Ruby Case Examples 38 mm Hepatic Artery Aneurysm Pulmonary AVM 2 Coils Dr. James Benenati Miami Cardiac and Vascular Institute, FL Y90 Embolization Type 2 Endoleak Dr. J Moskovitz Florida Hospital,

More information

Ureteroscopy solutions for your most challenging cases.

Ureteroscopy solutions for your most challenging cases. Ureteroscopy solutions for your most challenging cases. IT TAKES INSIGHT TO SEE THAT NO TWO STONE PATIENTS ARE ALIKE. THAT S THE DIFFERENCE BETWEEN MAKING DEVICES AND MAKING PROGRESS. There is nothing

More information

2.4 mm deflecting 2.4 mm tracking Above the knee Phoenix Below the knee 2.2 mm tracking 1.8 mm tracking

2.4 mm deflecting 2.4 mm tracking Above the knee Phoenix Below the knee 2.2 mm tracking 1.8 mm tracking Deep femoral artery Superficial femoral artery Popliteal artery Phoenix Above the knee Below the knee Atherectomy system Anterior tibial artery Peroneal artery Posterior tibial artery Dorsalis pedis artery

More information

RECOMMENDED INSTRUCTIONS FOR USE

RECOMMENDED INSTRUCTIONS FOR USE Rapid Exchange PTCA Dilatation Catheter RECOMMENDED INSTRUCTIONS FOR USE Available in diameters 1.25mm to 4.5mm and in lengths 09mm to 40mm Caution: This device should be used only by physicians trained

More information

Versatility and Proven Safety

Versatility and Proven Safety Versatility and Proven Safety Indicated for: Temporary or Permanent placement Standard or Over-The-Wire Delivery Jugular, Femoral, Antecubital, and Popliteal Access > Proven Safety Initial Clinical Trial

More information

Protecting Patients. Preserving Access.

Protecting Patients. Preserving Access. MAHURKAR * Family of Acute Care Catheters Protecting Patients. Preserving Access. A full spectrum of acute care catheters for use in hemodialysis, apheresis, infusion and renal replacement therapy The

More information

PressureWire Aeris with Agile Tip Technology. Wireless FFR Functionality and Handles like a Workhorse PCI Guidewire 1

PressureWire Aeris with Agile Tip Technology. Wireless FFR Functionality and Handles like a Workhorse PCI Guidewire 1 Home» Products» All International Products» PressureWire Aeris with Agile Tip Technology PressureWire Aeris with Agile Tip Technology This device is commercially available for use in select international

More information

NC EMERGE TM PTCA Dilatation Catheter

NC EMERGE TM PTCA Dilatation Catheter LEARN MORE Indications, contraindications, warnings and instructions for use can be found in the product labeling supplied with each device. Information for use only in countries with applicable health

More information

Optimized for Performance and Ease of Use. Designed with Titanium Oxide Surface. References

Optimized for Performance and Ease of Use. Designed with Titanium Oxide Surface. References References MicroVention data on file low Re-direction Endoluminal Device in treatment of cerebral aneurysms: initial experience with short-term follow-up results, Author: Naci Kocer et al. The RED and

More information

Pipeline Embolization Device

Pipeline Embolization Device Pipeline Embolization Device The power to redefine aneurysm treatment. REDEFINE The Pipeline device redefines treatment for large or giant wide-necked aneurysms by reconstructing the parent artery and

More information

Catheters and Wires. Dr. Vaibhav Jain MD,DNB,MNAMS Senior Consultant, IR Medanta, the Medicity, Gurgaon

Catheters and Wires. Dr. Vaibhav Jain MD,DNB,MNAMS Senior Consultant, IR Medanta, the Medicity, Gurgaon Catheters and Wires Dr. Vaibhav Jain MD,DNB,MNAMS Senior Consultant, IR Medanta, the Medicity, Gurgaon Guidewires: Guidewires (solid wires navigated within the vascular system / extravascular tract) act

More information

Protecting Patients. Preserving Access.

Protecting Patients. Preserving Access. MAHURKAR * Family of Acute Care Catheters Protecting Patients. Preserving Access. The Gold Standard Mahurkar * Acute Care Catheter Family Ease of insertion. Optimal flow rates. Patient comfort. A variety

More information

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER Page 1 of 5 NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER STERILE. SINGLE USE ONLY. Sterilized with ethylene oxide gas. Non pyrogenic. Do not resterilize. Do not use opened or damaged packages.

More information

Quick Reference Guide

Quick Reference Guide Quick Reference Guide Indications for Use The AFX Endovascular AAA System is indicated for endovascular treatment in patients with AAA. The devices are indicated for patients with suitable aneurysm morphology

More information

Colonic Metal Stents MAKING A DIFFERENCE TO HEALTH

Colonic Metal Stents MAKING A DIFFERENCE TO HEALTH Colonic Metal Stents In a fast paced and maturing market, Diagmed Healthcare s Hanarostent has managed to continue to innovate and add unique and clinically superior features to its already premium range.

More information

A CATHETER FAMILY FOR ALL YOUR PATIENT NEEDS

A CATHETER FAMILY FOR ALL YOUR PATIENT NEEDS A CATHETER FAMILY FOR ALL YOUR PATIENT NEEDS MAHURKAR * Elite acute dialysis catheter family EFFICIENCY OF DIALYSIS IN REVERSE FLOW Less than one percent recirculation Symmetrical tip design minimizes

More information

UC SF. Introduction: Retrograde Access. Pedal Access: When to Do It How Does it Fare. Introduction: Retrograde Access. Introduction: Retrograde Access

UC SF. Introduction: Retrograde Access. Pedal Access: When to Do It How Does it Fare. Introduction: Retrograde Access. Introduction: Retrograde Access Introduction: Retrograde Access Pedal Access: When to Do It How Does it Fare Wide spread application of endovascular techniques to infrageniculate arterial occlusive disease Technical failure rate of crossing

More information

Algorithm and Tools for the Uncrossable CTO

Algorithm and Tools for the Uncrossable CTO Algorithm and Tools for the Uncrossable CTO David E. Kandzari, MD, FACC, FSCAI Chief Scientific Officer Director, Interventional Cardiology Piedmont Heart Institute Atlanta, Georgia david.kandzari@piedmont.org

More information

System.

System. System www.penumbrainc.com POD System Case Examples 45 cm of POD Packing Coil in 1.5 to 3 mm diameter dilating vessel Bronchial Artery Embolization Dr. Amit Kakkar and Dr. Aksim Rivera, Bronx, NY Inflow:

More information

1 Comparison of Warfarin and Aspirin for Symptomatic Intracranial Arterial Stenosis. N Engl J Med 352;13, March 31, 2005

1 Comparison of Warfarin and Aspirin for Symptomatic Intracranial Arterial Stenosis. N Engl J Med 352;13, March 31, 2005 The risk of ischemic stroke in patients with Intracranial Atherosclerotic Disease (ICAD) ranges from 7 to 24%. 1,2 Developed specifically for the treatment of ICAD, the Wingspan Stent System and Gateway

More information

HLS CANNULAE SOLUTIONS FROM TIP TO TIP

HLS CANNULAE SOLUTIONS FROM TIP TO TIP HLS CANNULAE SOLUTIONS FROM TIP TO TIP HLS CANNULAE SETS VESSEL ACCESS BECOMES EASIER MAQUET THE GOLD STANDARD MAQUET is an international synonym for innovative and technological advances in operating

More information

Biliary Metal Stents MAKING A DIFFERENCE TO HEALTH

Biliary Metal Stents MAKING A DIFFERENCE TO HEALTH Biliary Metal Stents In a fast paced and maturing market, Diagmed Healthcare s Hanarostent has managed to continue to innovate and add unique and clinically superior features to its already premium range.

More information

SIS Medical AG. Standard PTCA Guide Wires. Key features

SIS Medical AG. Standard PTCA Guide Wires. Key features Standard 0.014 PTCA Guide Wires Key features - Excellent torque control - Superior navigation - Tapered shaping ribbon - Heat treated shaping ribbon to provide for easy J shaping combined with optimum

More information

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE INDICATIONS FOR USE The LATERA Absorbable Nasal Implant is indicated for supporting upper and lower lateral nasal cartilage. CAUTION: Federal law restricts

More information

Pocket Reference Guide For (CTO) Technologies

Pocket Reference Guide For (CTO) Technologies to receive our latest news and key activities. Pocket Reference Guide For (CTO) Technologies LinkedIn page Follow us on CORDIS EMEA Table of Contents Essential prescribing information for both FRONTRUNNER

More information

Gastric / EUS Metal Stents

Gastric / EUS Metal Stents Gastric / EUS Metal Stents In a fast paced and maturing market, Diagmed Healthcare s Hanarostent has managed to continue to innovate and add unique and clinically superior features to its already premium

More information

Endovascular Treatment of Aortoiliac Occlusive Disease: What s in My Toolbox in Jade S. Hiramoto, MD, MAS UCSF Vascular Symposium April 20, 2018

Endovascular Treatment of Aortoiliac Occlusive Disease: What s in My Toolbox in Jade S. Hiramoto, MD, MAS UCSF Vascular Symposium April 20, 2018 Endovascular Treatment of Aortoiliac Occlusive Disease: What s in My Toolbox in 2018 Jade S. Hiramoto, MD, MAS UCSF Vascular Symposium April 20, 2018 Disclosures Research support and royalties, Cook Inc.

More information

Indications. The AngioVac cannula is intended for use as a venous drainage cannula and for the removal of fresh, soft thrombi or emboli

Indications. The AngioVac cannula is intended for use as a venous drainage cannula and for the removal of fresh, soft thrombi or emboli Indications Straight Cannula or Cannula with 20 O Angle 17F Working Channel The AngioVac cannula is intended for use as a venous drainage cannula and for the removal of fresh, soft thrombi or emboli Radiopaque

More information

Solving the Dilemma of Ostial Stenting: A Case Series Illustrating the Flash Ostial System

Solving the Dilemma of Ostial Stenting: A Case Series Illustrating the Flash Ostial System Volume 1, Issue 1 Case Report Solving the Dilemma of Ostial Stenting: A Case Series Illustrating the Flash Ostial System Robert F. Riley * and Bill Lombardi University of Washington Medical Center, Division

More information

SURPASS FLOW DIVERTER

SURPASS FLOW DIVERTER SURPASS FLOW DIVERTER SCENT TRIAL UPDATE Ajay K. Wakhloo, M.D., Ph.D., FAHA Department of Radiology, Neurology and Neurosurgery Division Neuroimaging and Intervention University of Massachusetts SVIN -

More information

DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS

DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS HALYARD* MIC* AND MIC-KEY* INTRODUCER KITS HALYARD* MIC* and MIC-KEY* Introducer Kits provide physicians with an innovative solution to facilitate the primary

More information

LINEAR 7.5Fr. IAB Catheter

LINEAR 7.5Fr. IAB Catheter LINEAR 7.5Fr. IAB Catheter The LINEAR 7.5Fr. Catheter Easier to insert* Proprietary IAB Membrane provides better performance* Abrasion resistance improved 43%* Improved fatigue resistance* Immediate inflation

More information

Integra Miltex. Endodontic Files. Limit uncertainty with the brand you trust

Integra Miltex. Endodontic Files. Limit uncertainty with the brand you trust Limit uncertainty with the brand you trust Liberator Niti Rotary Files The Rotary File that Will Not Self-Thread Liberator rotary nickel-titanium endodontic files are the result of years of research and

More information

Appropriate Device Selection for Endovascular Procedures

Appropriate Device Selection for Endovascular Procedures Appropriate Device Selection for Endovascular Procedures Thomas M. Shimshak, MD Florida Hospital Heartland Medical Center Sebring, Florida Disclosures Speaker s Bureau: Abbott Vascular Boston Scientific

More information

Angioplasty Summit TCTAP Technical Aspects of Overview in CTO-PCI Toyohashi Heart Center Takahiko Suzuki, M.D

Angioplasty Summit TCTAP Technical Aspects of Overview in CTO-PCI Toyohashi Heart Center Takahiko Suzuki, M.D Angioplasty Summit TCTAP 2010 Technical Aspects of Overview in CTO-PCI Toyohashi Heart Center Takahiko Suzuki, M.D Introduction CTO-PCI has been technically and technologically evolved over the past two

More information

EluNIR. Ridaforolimus Eluting Coronary Stent System. Advancing Deliverability for the Road Ahead

EluNIR. Ridaforolimus Eluting Coronary Stent System. Advancing Deliverability for the Road Ahead Ridaforolimus Eluting Coronary Stent System Advancing Deliverability for the Road Ahead The Coronary Stent System Raising the Bar on Drug-Eluting Stent Technology Introducing the Coronary Stent System,

More information

PTA Balloon Dilatation Catheter

PTA Balloon Dilatation Catheter PTA Balloon Dilatation Catheter March 2016 1/6(3214-0) Catalogue number Serial number Lot number Use by Do not reuse Do not resterilize Do not use if package is damaged Consult instructions for use Keep

More information

ROTABLATORTM. Peripheral. Rotational Atherectomy System. Quick Reference Cards

ROTABLATORTM. Peripheral. Rotational Atherectomy System. Quick Reference Cards Peripheral ROTABLATORTM Rotational Atherectomy System Quick Reference Cards Technical Assistance: 1.800.949.6708 Customer Service: 1.888.272.1001 Complaints: 1.800.811.3211 Setup Video: www.bostonscientific.com/rotablatorsetup

More information

SENSATION and CS300 Smaller meets faster. IABP System

SENSATION and CS300 Smaller meets faster. IABP System SENSATION and CS300 Smaller meets faster IABP System Cardiac Assist SENSATION and CS300 3 Cardiac Assist SENSATION and CS300 5 Smaller The SENSATION 7Fr. Fiber-Optic IAB Catheter Faster The CS300 with

More information

Proven Performance Through Innovative Design *

Proven Performance Through Innovative Design * Proven Performance Through Innovative Design * Deliver Our Next Generation AV Covered Stent Results The COVERA Vascular Covered Stent builds upon proven technologies from the category leader in AV Access.

More information

i INTERACTIVE CATALOG FIND YOUR IDEAL CANNULAE

i INTERACTIVE CATALOG FIND YOUR IDEAL CANNULAE i INTERACTIVE CATALOG FIND YOUR IDEAL CANNULAE Catalog 2017 i USER TIPS Easily navigate through the pages in our 2017 Cannula Catalog by using the mini-menu shown on upper right of each page. Navigate

More information

Cordis VISTA BRITE TIP

Cordis VISTA BRITE TIP to receive our latest news and key activities. Cordis VISTA BRITE TIP Guiding Catheter LinkedIn page Follow us on CORDIS EMEA Designed for support and performance Giving you the confidence and support

More information

MICRO-TECH Europe. MICRO-TECH Colon and rectum stents. Colon and rectum stents

MICRO-TECH Europe. MICRO-TECH Colon and rectum stents. Colon and rectum stents MICRO-TECH Europe MICRO-TECH. MICRO-TECH Europe Colon and rectum stents OTW. Maximum hold for maximum patient comfort. Colon stents demand a particularly high positional stability. The OTW colon and rectum

More information

INNOVATIVE TWO-IN- ONE FUNCTIONALITY. ARROW GPSCATH FEATURING VISIOVALVE Navigate with confidence

INNOVATIVE TWO-IN- ONE FUNCTIONALITY. ARROW GPSCATH FEATURING VISIOVALVE Navigate with confidence INNOVATIVE TWO-IN- ONE FUNCTIONALITY ARROW GPSCATH FEATURING VISIOVALVE Navigate with confidence TELEFLEX PRESENTS THE ARROW GPSCATH TM BALLOON DILATATION CATHETER NOW FOR BTK* Below-the-knee interventions

More information

Peripheral Intravascular Lithotripsy (IVL) Catheter Instructions for Use (IFU)

Peripheral Intravascular Lithotripsy (IVL) Catheter Instructions for Use (IFU) Peripheral Intravascular Lithotripsy (IVL) Catheter Instructions for Use (IFU) For use with the Shockwave Medical, Inc. IVL Generator and Connector Cable Indication for Use The Shockwave Medical IVL System

More information

Indications for use. Contraindications within the United States

Indications for use. Contraindications within the United States Indications for use Indications within the United States The GORE TAG Thoracic Endoprosthesis is intended for endovascular repair of all lesions of the descending thoracic aorta, including: Isolated lesions

More information

Cordis ExoSeal. Maximise Clinical Safety*. The novel approach to secure and easy closure. Vascular Closure Device CORDIS EXOSEAL VCD

Cordis ExoSeal. Maximise Clinical Safety*. The novel approach to secure and easy closure. Vascular Closure Device CORDIS EXOSEAL VCD Cordis ExoSeal Vascular Closure Device CORDIS EXOSEAL VCD Maximise Clinical Safety*. The novel approach to secure and easy closure. * Clinical data from the ECLIPSE Trial indicates safety in terms of vascular

More information

THE ENVOY FAMILY OF GUIDING CATHETERS. Supporting your neurointerventional access needs

THE ENVOY FAMILY OF GUIDING CATHETERS. Supporting your neurointerventional access needs THE ENVOY FAMILY OF GUIDING CATHETERS Supporting your neurointerventional access needs VERSATILITY & CHOICE ENVOY FAMILY OF GUIDING CATHETERS Innovating in guiding catheter technology and building on the

More information

Straub Endovascular System &

Straub Endovascular System & Straub Endovascular System & S t r a u b E n d o v a s c u l a r To o l s Straub Endovascular System Effective debulking in occluded arteries and veins Effective debulking in many indications Rotarex

More information

Finally, the Control You Need to Deliver Accurate Treatment

Finally, the Control You Need to Deliver Accurate Treatment Finally, the Control You Need to Deliver Accurate Treatment LIFESTREAM Covered Stent. has joined BD When you reach for a balloon expandable stent, you require accuracy. The LIFESTREAM Balloon Expandable

More information

LINEAR. 7.5Fr. IAB Catheter. This document is intended to provide information to an international audience outside of the US.

LINEAR. 7.5Fr. IAB Catheter. This document is intended to provide information to an international audience outside of the US. LINEAR 7.5Fr. IAB Catheter This document is intended to provide information to an international audience outside of the US. Maquet offers a range of convenient and innovative clinical solutions for counterpulsation

More information

THE THE MORE MORE NATURAL APPROACH TO OPTIMAL FIT

THE THE MORE MORE NATURAL APPROACH TO OPTIMAL FIT THE THE MORE MORE NATURAL APPROACH Natural Approach TO Optimal Fit TO OPTIMAL FIT Conformability without Compromise THE STANDARD IN Conformability AND Designed for flexibility and conformability in tortuous

More information

PTA Balloon Dilatation Catheter

PTA Balloon Dilatation Catheter PTA Balloon Dilatation Catheter 1/6(3211-0) February 2016 TIS-488-06272017 Catalogue number Serial number Lot number Use by Do not reuse Do not resterilize Do not use if package is damaged Consult instructions

More information

Chronic total occlusions (CTOs) are frequently

Chronic total occlusions (CTOs) are frequently Specialty Crossing Devices: Understanding the Learning Curve Technical pearls and new devices for crossing peripheral CTOs. y Usman Javed, MD, and John R. Laird, MD (Courtesy of ard Peripheral Vascular,

More information

Extracorporeal Circuit Cannulae { VENOUS}

Extracorporeal Circuit Cannulae { VENOUS} Extracorporeal Circuit Cannulae { VENOUS} Medtronic are designed to provide optimal venous drainage while providing flexibility and ease of use. We offer a variety of single stage venous cannulae with

More information

AXS Catalyst Distal Access Catheter

AXS Catalyst Distal Access Catheter AXS Catalyst Distal Access Catheter Directions for Use 2 AXS Catalyst Distal Access Catheter ONLY Caution: Federal Law (USA) restricts this device to sale by or on the order of a physician. warning Contents

More information

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up Zenith Renu AAA Converter Graft Device Description Planning and Sizing Deployment Sequence Patient Follow-Up Device description: Device indications The Zenith Renu AAA Converter Graft with Z-Trak Introduction

More information

Balloon in Balloon (BIB )

Balloon in Balloon (BIB ) in (BIB ) Dilatation Catheter INSTRUCTIONS FOR USE CAUTION: FEDERAL (USA) LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN. Read all instructions prior to use. Distributed by: B. Braun

More information

Single Pass MCA Revascularization with Trevo

Single Pass MCA Revascularization with Trevo Single Pass MCA Revascularization with Trevo By Concentric Medical ProVueTM Retriever Case Reported By Sascha Prothmann, MD Klinikum rechts der Isar, Munich, Germany Images contained herein courtesy of

More information

Maximise Clinical Safety*. Cordis ExoSeal. The novel approach to secure and easy closure. Vascular Closure Device CORDIS EXOSEAL VCD

Maximise Clinical Safety*. Cordis ExoSeal. The novel approach to secure and easy closure. Vascular Closure Device CORDIS EXOSEAL VCD Cordis ExoSeal Vascular Closure Device Cardiology and Endovascular CORDIS EXOSEAL VCD Maximise Clinical Safety*. The novel approach to secure and easy closure. * Clinical data from the ECLIPSE Trial indicates

More information

Instructions for Use 1

Instructions for Use 1 Instructions for Use 1 Instructions for Use IMPORTANT! Please read before use. Description The Sniper is a dual lumen catheter comprised of an inner guidewire/infusion lumen and an outer, annular lumen

More information

INNOVATIVE PRODUCTS G, J AND GJ-TUBES WITH ENFit TM CONNECTION

INNOVATIVE PRODUCTS G, J AND GJ-TUBES WITH ENFit TM CONNECTION MIC * & MIC-KEY * Enterostomy Tubes INNOVATIVE PRODUCTS G, J AND GJ-TUBES WITH ENFit TM CONNECTION DIGESTIVE HEALTH PRODUCT CATALOGUE INNOVATIVE PRODUCTS - G, J AND GJ-TUBES WITH ENFit TM CONNECTION DIGESTIVE

More information

PTCA Dilatation Catheter. Instructions for Use

PTCA Dilatation Catheter. Instructions for Use PTCA Dilatation Catheter Instructions for Use Rx ONLY Caution: Federal law restricts this device to sale by or on the order of a physician STERILE. Sterilized with ethylene oxide gas Distributed by Medinol

More information

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER Page 1 of 5 ASPIRATION CATHETER Carefully read all instructions prior to use, observe all warnings and precautions noted throughout these instructions. Failure to do so may result in complications. STERILE.

More information

Peripheral Embolization Products

Peripheral Embolization Products Peripheral Embolization Products PRODUCT CATALOG AND ORDERING INFORMATION Setting Standards. Exceeding Expectations. BOSTON SCIENTIFIC Peripheral Embolization Solved Complete Offering Throughout our history,

More information

LOWERING THE PROFILE RAISING THE BAR

LOWERING THE PROFILE RAISING THE BAR LOWERING THE PROFILE RAISING THE BAR INNOVATIVE LOW PROFILE. ADVANCED CLINICAL PERFORMANCE. The AFX TM Endovascular AAA System integrates anatomical fixation with an advanced delivery system and graft

More information

Part 1: General requirements

Part 1: General requirements Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 10555-1 Second edition 2013-06-15 Corrected version 2014-01-15 Intravascular catheters Sterile and single-use catheters Part 1: General requirements

More information

-vita THORACIC 3G. Stent Graft System SOLUTIONS FOR VASCULAR DISEASE

-vita THORACIC 3G. Stent Graft System SOLUTIONS FOR VASCULAR DISEASE Stent Graft SOLUTIONS FOR VASCULAR DISEASE 1 PURE PERFORMANCE AND QUALITY: STENT GRAFT SYSTEMS BY JOTEC JOTEC is an innovation-oriented company with consistent focus on its core competencies: the development

More information

5F Devices with 0.035

5F Devices with 0.035 Ambulatory mamagement for PAD endovascular treatment 5F Devices with 0.035 Flavio Airoldi, MD Multmedica IRCCS Milan - ITALY flavio.airoldi@multimedica.it Is there a need for low profile delivery systems?

More information