Ultrasonic Transducer. Piezoelectric ceramics / Piezoelectric polymer film / Piezoelectric thin film

Size: px
Start display at page:

Download "Ultrasonic Transducer. Piezoelectric ceramics / Piezoelectric polymer film / Piezoelectric thin film"

Transcription

1 Ultrasonic Piezoelectric ceramics / Piezoelectric polymer film / Piezoelectric thin film

2 Ultrasonic Technology is gentle both to the Earth and humankind Diminution of negative influences to the environment, which are caused by certain human activities, has now become an urgent and important theme worldwide. From the ordinary life patterns of humankind to industrial operations, a balance of what is beneficial to the environment must be achieved. Ultrasonics is indispensable in the search for solutions that will preserve a wellbalanced and clean environment. Ultrasonics is demonstrating its capabilities in the analysis of damaging materials like dioxin, and also in the definition of bio-fuel in the water. With the utilization of ultrasonic technology, Honda Electronics Company, Limited will continually endeavor to achieve solutions that will aid in the prevention of pollution to the environment. Piezoelectric ceramics anion cation Contracts when a potential is applied to the upper part and a potential to the lower part Expands when a potential is applied to the upper part and a potential to the lower part. Apply pressure. Acoustic sounds are generated just by hitting an object. The generation of high frequency ultrasound, requires a special method. A transducer made of a piezoelectric ceramic material repetitively contracts and expands when subject to alternating voltage. Conversely, when alternating pressures are applied to the transducer, alternating voltage appears across the transducer. This is the piezoelectric effect. The transducer is also called an electroacoustic element. A piezoelectric ceramic material is a polycrystal ceramic made by compressing a high purity powder (titanium oxide, barium oxide, etc.) and firing it at a high temperature. When a polarization process is applied, this ceramic material attains a piezoelectric property similar to that of a single crystal such as quartz. Ultrasonic transducers based on the piezoelectric ceramics are the key technology supporting the advance of ultrasonic devices. 1

3 Piezoelectric ceramics, piezoelectric polymer film, and piezoelectric thin film are used as piezoelectric materials to generate ultrasound. Piezoelectric ceramicsbatio3, PZT, PbTiO3,(Bi,Na)TiO3 Piezoelectric ceramics is polycrystal ceramics made by compressing a high purity powder such as titanium oxide and barium oxide and firing it at a high temperature. The piezoelectric property is obtained through a polarization process. Piezoelectric polymer filmpvdf-trfe A piezoelectric polymer film is produced by forming a film from molten polymer or its solution, and applying a polarization process to the film. This type of piezoelectric material is characterized by very low acoustic impedance, flexibility and ease of forming a thin film from a solution. Piezoelectric thin filmzno A piezoelectric thin film is made by sputtering zinc oxide (ZnO). To make an ultrasonic transducer, zinc oxide film is formed on a substrate such as quartz or sapphire in a C-axis orientation. Table of physical properties Property Unit Symbol HC-70BN HC-60AH HC-50GS HC-51GS HC-40H HC-30D Zn-P Coupling factors k p k 31 k 33 Dielectric constants T 33 0 constants N p N 31 N 33 Piezoelectric strain constants d 31 d 33 Piezoelectric voltage constants g 31 g 33 Youngs modulus E Y 33 Mechanical Q Qm Dissipation factor tan Poisson ratio Density Curie point Cleaning Flaw detection Thickness measurement Medical diagnosis Airborne level measurement Fish finding Cleaning Machining Atomizing Welding Cleaning Machining Atomizing Welding Flaw detection Thickness measurement Medical diagnosis Fish finding Airborne level measurement Microscopy Flaw detection 2

4 Types of ultrasonic transducer Piezoelectric ceramics transducer Shape of electrode Double-sided electrode Folded electrode Piezoelectric polymer film / ZnO thin film Ultrasonic flaw detector Ultrasonic microscope Polymer film ZnO thin film Bolt clamped Langevin type transducer for cleaner Because of piezoelectric ceramics is mechanically combined, the transducer is very durable free from damage even under the high amplitude vibrations. Furthermore, it is possible for stable operation with high electroacoustic conversion efficiency and less heat generation. PZT type Thickness vs torque Mass(g) Diameter(mm) Length(mm) Joint screw size (khz) Measurement voltage(vrms) Impedance () Static capacity (pf) Max. input power (W) Thickness Installation (mm) torque(nm) (30 or less) (50 or less) (35 or less) (35 or less) (30 or less) (35 or less) The installation torque value is a standard. (Bi,Na)TiO3 type Lead-Free Piezoelectric Ceramics Thickness vs torque Mass(g) Diameter(mm) Length(mm) Joint screw size (khz) Measurement voltage(vrms) Impedance () Static capacity (pf) Max. input power (W) Thickness Installation (mm) torque(nm) is Honda's brand name of lead-free piezoelectric ceramics. The installation torque value is a standard. 3

5 Bolt clamped Langevin type transducer for process machinery A high amplitude can be achieved with high electroacoustic conversion efficiency, low mechanical vibration loss, and less heat generation thanks to the original structure design. Mass(g) Diameter(mm) Length(mm) Joint screw size (khz) Measurement voltage(vrms) Admittance (ms) Static capacity (pf) Max. input power (W) (Nm) Transmission installation torque The installation torque value is a standard. for high power process machinery A high-power transducer achieves high amplitude and low heat generation with a structure where intermediate heat radiation plates are inserted between ceramics. Mass(g) Diameter(mm) Length(mm) Joint screw size (khz) Measurement voltage(vrms) Admittance (ms) Static capacity (pf) Max. input (Nm) power(w) Transmission installation torque The installation torque value is a standard. 4

6 Expansion of s Ultrasonic cleaning : Ultrasonic cleaners (tank typewater flow type)/ultrasonic defoaming s for ultrasonic cleaning are used not only for cleaning but also for stirring, defoaming, and many other technologies.with its load stability, this type of transducer is best suited for gaining high output power. *For details of ultrasonic cleaners, please refer to their brochures. Ultrasonic cleaner Pizo-ceramics Bolt clamped Langevin type Ultrasonic machining : Ultrasonic welder/ultrasonic cutter s for ultrasonic machining, which use materials with small inner mechanical loss, have superior characteristics of high electrical conversion efficiency that enables large-amplitude vibration with low heat generation. Ultrasonic welder Ultrasonic cutter Bolt clamped Langevin type (with a horn) Bolt clamped Langevin type (with a horn) Ultrasonic underwater measurement : Ultrasonic fish finder/ultrasonic interface level meter s for ultrasonic underwater measurements generate ultrasonic waves in the water to get and display image information obtained by ultrasonic pulses reflected on a school of fish or the seabed. Ultrasonic fish finder Ultrasonic fish finder Ultrasonic interface level meter Bolt clamped Langevin type Pizo-ceramics Pizo-ceramics Ultrasonic airborne measurement : Airborne ultrasonic level meter/doppler speedmeter s for ultrasonic airborne measurement generate ultrasonic waves in the air to get and display information (distance, reflection intensity, move speed) obtained by ultrasonic pulses reflected on various objects. Airborne level meter Airborne sensor Ceramics (with an acoustic matching layer) Ceramics (with an acoustic matching layer) 5

7 Ultrasonic measurement : Ultrasonic flaw detecting and imaging system/ultrasonic microscope/ultrasonic medical diagnosis equipment s for ultrasonic measurement are used in a relatively high frequency band from 1MHz to 400MHz. Base on the recent evolution of ultrasonic technologies, this type of transducer has become an necessity in the medical diagnosis field and the non-destructive testing field. Ultrasonic microscope Ultrasonic flaw detecting and imaging system Ultrasonic medical diagnosis equipment Ultrasonic flow meter Piezoelectric thin film (with an acoustic lens) Ceramics (with an acoustic matching layer) Piezoelectric polymer film Ceramics (with an acoustic matching layer) Pizo-ceramics Notes on Usage Products and specifications described in this catalogue are subject to change or discontinuation without notice due to improvements. The delivery specifications should always be requested to check the details before use. The performance and quality of each product are guaranteed to the limits stated in this catalogue, however, evaluation and confirmation of factors such as suitability of piezoelectric ceramic materials, mounting methods, and drive methods for the products are required in their actual mounted state prior to us, according to customer requirements. Failure to use products in accordance with the specifications (including performance, ratings, and usage range) indicated in this catalogue may result in physical injury, fire, or social loss. If you have any questions regarding usage, please feel free to contact Honda Electronics. The products described in this catalogue are intended for use with standard equipment. Customers considering use with equipment or systems requiring exceptionally high reliability and safety should confirm the suitability of products prior to their use. Please note that Honda Electronics accepts no responsibility for any problems related to the intellectual property of third parties resulting from the use of these products, except for issues directly related to Honda Electronics' product construction and manufacturing processes. The details contained in this catalogue are correct as of September

8 Honda Electronics Co., Ltd. is certified and registered to be in conformity with ISO9001/ISO13485/ISO Oyamazuka, Oiwacho, Toyohashi, Aichi , Japan TEL : FAX : URL /

PZT/ZnO EXPERIMENT MODELLING

PZT/ZnO EXPERIMENT MODELLING Mat. Res. Soc. Symp. Proc. Vol. 655 2001 Materials Research Society High Frequency Thin Film Acoustic Ferroelectric Resonators Paul Kirby a, Qing-Xin Su a, Eiju Komuro b, Masaaki Imura b, Qi Zhang, and

More information

GUIDANCE NOTE. Application of MEMS Ultrasonic Transducers to Flow Measurement.

GUIDANCE NOTE. Application of MEMS Ultrasonic Transducers to Flow Measurement. GUIDANCE NOTE Application of MEMS Ultrasonic Transducers www.tuvnel.com Application of MEMS Ultrasonic Transducers Introduction This Guidance Note provides a review of the key issues associated with the

More information

Intrinsically Safe Ultrasonic Testers: How important are they?

Intrinsically Safe Ultrasonic Testers: How important are they? Intrinsically Safe Ultrasonic Testers: How important are they? Introduction The use of ultrasonic devices for non-destructive testing (NDT) has become more common in recent years as equipment has increased

More information

Sound in medicine. CH.12. Dr.Rajaa أ.م.د. رجاء سهيل جنم جامعة تكريت كلية طب االسنان. General Properties of Sound

Sound in medicine. CH.12. Dr.Rajaa أ.م.د. رجاء سهيل جنم جامعة تكريت كلية طب االسنان. General Properties of Sound CH.12. Dr.Rajaa Sound in medicine أ.م.د. رجاء سهيل جنم جامعة تكريت كلية Sound : It is the audible waves of frequency between 20 Hz and 20 khz. Infrasound : refers to the sound of frequency below the normal

More information

Ultrasonic Condition Monitoring MORE THAN JUST A LEAK DETECTOR

Ultrasonic Condition Monitoring MORE THAN JUST A LEAK DETECTOR Innovative Sound Solutions TM Ultrasonic Condition Monitoring MORE THAN JUST A LEAK DETECTOR Presented by Benjamin Fried May, 2006 CTRL Systems, Inc. 1004 Littlestown Pike, Suite H Westminster, MD 21157

More information

Can you believe that the ultrasonic waves are used for cleaning purpose???

Can you believe that the ultrasonic waves are used for cleaning purpose??? Introduction (Ultrasonic Cleaning Unit) Can you believe that the ultrasonic waves are used for cleaning purpose??? Learning Objectives On completion of this chapter you will be able to: 1. Describe the

More information

NMIJ measurement service on ultrasonic field parameters available to demonstrate performance and safety of ultrasonic medical equipment

NMIJ measurement service on ultrasonic field parameters available to demonstrate performance and safety of ultrasonic medical equipment NMIJ measurement service on ultrasonic field parameters available to demonstrate performance and safety of ultrasonic medical equipment Masahiro Yoshioka National Metrology Institute of Japan (NMIJ) National

More information

Ultrasonic Testing Level I:

Ultrasonic Testing Level I: Ultrasonic Testing Level I: 1- Sound Wave - Introduction - ASNT Level I - Sound Wave Propagation - Velocity / Frequency / Wave Length - Acoustic Impedance - Energy / Intensity 2- Ultrasound Wave Modes

More information

AN EXPERIMENTAL STUDY ON TRANSDUCER FOR THE DDS TECHNOLOGY DEMONSTRATOR ANDRZEJ ELMINOWICZ, WALDEMAR LIS*, WŁADYSŁAW MĘCIŃSKI

AN EXPERIMENTAL STUDY ON TRANSDUCER FOR THE DDS TECHNOLOGY DEMONSTRATOR ANDRZEJ ELMINOWICZ, WALDEMAR LIS*, WŁADYSŁAW MĘCIŃSKI AN EXPERIMENTAL STUDY ON TRANSDUCER FOR THE DDS TECHNOLOGY DEMONSTRATOR ANDRZEJ ELMINOWICZ, WALDEMAR LIS*, WŁADYSŁAW MĘCIŃSKI R&D Marine Technology Centre Dickmana 62, 81-109 Gdynia, Poland, *University

More information

Heat Drain Device for Ultrasound Imaging Probes ESAOTE SPA

Heat Drain Device for Ultrasound Imaging Probes ESAOTE SPA Heat Drain Device for Ultrasound Imaging Probes ESAOTE SPA L. Spicci, G. Vigna TRANSDUCER STRUCTURE OVERVIEW Finished probe Complete transducer Silicon lens Filling resin INTRODUCTION Electrical driving

More information

Descriptions of NDT Projects Fall 2004 October 31, 2004

Descriptions of NDT Projects Fall 2004 October 31, 2004 Descriptions of NDT Projects Fall 2004 October 31, 2004 Introduction There are two separate NDT labs in Magister: ULTRA for ultrasound and EDDY for eddy current. Both labs are equipped with mechanical

More information

Characteristics of Liquids Atomization Using Surface Acoustic Wave

Characteristics of Liquids Atomization Using Surface Acoustic Wave Characteristics of Liquids Atomization Using Surface Acoustic Wave Minoru Kurosawa, Akira Futami, and Toshiro Higuchi Dept. of Precision Machinery Engineering, The University of Tokyo, Hongo, Bunkyo-ku,

More information

COURSE DESCRIPTION FOR NONDESTRUCTIVE TESTING

COURSE DESCRIPTION FOR NONDESTRUCTIVE TESTING COURSE DESCRIPTION FOR NONDESTRUCTIVE TESTING TULSA, OKLAHOMA INTRODUCTION TO NONDESTRUCTIVE TESTING QCT1817 COURSE DESCRIPTION: In this course students will learn about materials and processes, find basic

More information

A Facile Method for Enhancing the Sensing Performance of Zinc Oxide. Nanofibers Gas Sensors

A Facile Method for Enhancing the Sensing Performance of Zinc Oxide. Nanofibers Gas Sensors Electronic Supplementary Information (ESI): A Facile Method for Enhancing the Sensing Performance of Zinc Oxide Nanofibers Gas Sensors Pei-Pei Wang a, Qi Qi a, Rui-Fei Xuan a,b, Jun Zhao a, Li-Jing Zhou

More information

Ultrasonic Testing of Composite Structures

Ultrasonic Testing of Composite Structures I. Introduction Ultrasonic Testing of Composite Structures This section of this work defines ultrasound basic concepts and Ultrasonic Technique. It describes the details of how ultrasonic testing works,

More information

Fabrication of Zinc Oxide Thin Films for Acoustic Resonators

Fabrication of Zinc Oxide Thin Films for Acoustic Resonators Fabrication of Zinc Oxide Thin Films for Acoustic Resonators Glen R. Kowach Materials Research Department, Bell Labs Murray Hill, NJ USA 550 o C ZnO Pt SiO 2 Si top view cross-section Collaborators film

More information

Custom-Made Products / Scientific Research Instruments

Custom-Made Products / Scientific Research Instruments Synchrotron Radiation Instruments Double Crystal Monochromator A double crystal monochromator is an instrument that extracts light of a specific wavelength using crystal diffraction. Light of various wavelengths

More information

IEC 87: Ultrasonics Overview update July 2002

IEC 87: Ultrasonics Overview update July 2002 - 1 - CCAUV/02-07 IEC 87: Ultrasonics Overview update July 2002 Roy C Preston Secretary IEC TC 87: Ultrasonics British Electrotechnical Committee, British Standards Institution, 389 Chiswick High Road,

More information

Solution range. Superior accuracy in surface interaction analysis

Solution range. Superior accuracy in surface interaction analysis Solution range Superior accuracy in surface interaction analysis [ Q-SENSE ] Explore the nanoscale world with Q-Sense Based on established and powerful quartz crystal microbalance with dissipation (QCM-D)

More information

We are providing Level I, II Training and Certification as per Recommended practice SNT TC 1A 2006 in the following NDT Methods.

We are providing Level I, II Training and Certification as per Recommended practice SNT TC 1A 2006 in the following NDT Methods. INTRODUCTION: Metal lab is built on strong Material Testing & Non - Destructive Testing, NDT Training & certification Courses expertise, founded in 2004 by group of professionals to serve the industry.

More information

Ultrasonic Instruments for Non-Destructive Testing

Ultrasonic Instruments for Non-Destructive Testing Ultrasonic Instruments for Non-Destructive Testing SCOPE The SoniSys Out-of-Plane Ultrasonic System, OPUS, is a unique ultrasonic system providing non-destructive Z- direction analysis of materials including

More information

(12) United States Patent (10) Patent No.: US 6,691,578 B1

(12) United States Patent (10) Patent No.: US 6,691,578 B1 USOO6691578B1 (12) United States Patent (10) Patent No.: US 6,691,578 B1 Puskas (45) Date of Patent: Feb. 17, 2004 (54) MEASUREMENT SYSTEMS FOR 4,710,233 A 12/1987 Hohmann et al.... 205/701 ULTRASOUND

More information

Ultrasonic transducers

Ultrasonic transducers Woodhead Publishing Series in Electronic and Optical Materials; Number 29 Ultrasonic transducers Materials and design for sensors, actuators and medical applications Edited by K. Nakamura Oxford Cambridge

More information

HiFFUT A New Class of Transducer

HiFFUT A New Class of Transducer HiFFUT A New Class of Transducer Kick-Off Meeting Dr Andrew Feeney, Postdoctoral Research Fellow My Background I obtained a Master s degree in Mechanical Engineering from the University of Glasgow in 2010

More information

High ultrasonic power standard by calorimetric method in NMIJ. Takeyoshi Uchida Masahiro Yoshioka

High ultrasonic power standard by calorimetric method in NMIJ. Takeyoshi Uchida Masahiro Yoshioka High ultrasonic power standard by calorimetric method in NMIJ Takeyoshi Uchida Masahiro Yoshioka 1 Typical method for measuring ultrasonic power Radiation force balance (RFB) method A method measuring

More information

Performance of phased array and conventional ultrasonic probes on the new ISO reference block

Performance of phased array and conventional ultrasonic probes on the new ISO reference block Performance of phased array and conventional ultrasonic probes on the new ISO 19675 reference block C. Udell, D. Chai 1 and F. Gattiker Proceq S.A., Ringstrasse 2, Schwerzenbach, Switzerland. More info

More information

Evaluation of the Quality of Thick Fibre Composites Using Immersion and Air- Coupled Ultrasonic Techniques

Evaluation of the Quality of Thick Fibre Composites Using Immersion and Air- Coupled Ultrasonic Techniques ECNDT 2006 - We.1.6.4 Evaluation of the Quality of Thick Fibre Composites Using Immersion and Air- Coupled Ultrasonic Techniques Kaj K. BORUM, Risø National Laboratory, Materials Research Department, Roskilde,

More information

A PRELIMINARY ANALYSIS OF POSSIBILITIES OF COMPENSATING FAULTS OF LASER AND ULTRASONIC TECHNOLOGIES IN SURGERY. Tadeusz GUDRA, Sylwia MUC

A PRELIMINARY ANALYSIS OF POSSIBILITIES OF COMPENSATING FAULTS OF LASER AND ULTRASONIC TECHNOLOGIES IN SURGERY. Tadeusz GUDRA, Sylwia MUC ARCHIVES OF ACOUSTICS 32, 4 (Supplement), 117 122 (2007) A PRELIMINARY ANALYSIS OF POSSIBILITIES OF COMPENSATING FAULTS OF LASER AND ULTRASONIC TECHNOLOGIES IN SURGERY Tadeusz GUDRA, Sylwia MUC Wrocław

More information

HiFFUT A New Class of Transducer

HiFFUT A New Class of Transducer HiFFUT A New Class of Transducer Project Meeting April 2017 Dr Andrew Feeney Study of the electro-mechanical behaviour of flexural ultrasonic transducers This work will help us to design HiFFUTs for particular

More information

LIQUID JUNCTION PHOTOCELLS SYNTHESIZED WITH DYE COATED ZINC OXIDE FILMS. Department of Physics, University of Peradeniya, Peradeniya, Sri Lanka

LIQUID JUNCTION PHOTOCELLS SYNTHESIZED WITH DYE COATED ZINC OXIDE FILMS. Department of Physics, University of Peradeniya, Peradeniya, Sri Lanka J Sci.Univ.Kelaniya 5 (2010) : 25-31 LIQUID JUNCTION PHOTOCELLS SYNTHESIZED WITH DYE COATED ZINC OXIDE FILMS P. SAMARASEKARA Department of Physics, University of Peradeniya, Peradeniya, Sri Lanka Email:

More information

DEVELOPMENT OF ULTRASONIC TESTING TECHNIQUE TO INSPECT CONTAINMENT LINERS EMBEDDED IN CONCRETE ON NUCLEAR POWER PLANTS

DEVELOPMENT OF ULTRASONIC TESTING TECHNIQUE TO INSPECT CONTAINMENT LINERS EMBEDDED IN CONCRETE ON NUCLEAR POWER PLANTS DEVELOPMENT OF ULTRASONIC TESTING TECHNIQUE TO INSPECT CONTAINMENT LINERS EMBEDDED IN CONCRETE ON NUCLEAR POWER PLANTS H. Ishida 1, Y. Kurozumi 1, and Y. Kaneshima 2 1 Institute of Nuclear Safety System,

More information

Multielement ultrasonic probes for projection imaging of biological media

Multielement ultrasonic probes for projection imaging of biological media Available online at www.sciencedirect.com Physics Physics Procedia 3 (2010) 00 (2009) 635 642 000 000 www.elsevier.com/locate/procedia International Congress on Ultrasonics, Universidad de Santiago de

More information

AlN/ZnO/Silicon Structure Combining Surface Acoustic Waves and Waveguiding Layer Acoustic Wave

AlN/ZnO/Silicon Structure Combining Surface Acoustic Waves and Waveguiding Layer Acoustic Wave Excerpt from the Proceedings of the COMSOL Conference 2010 Paris AlN/ZnO/Silicon Structure Combining Surface Acoustic Waves and Waveguiding Layer Acoustic Wave O. Legrani*, O. Elmazria*, S. Zhgoon +, L.

More information

Ultrasonic Testing (UT) Technique

Ultrasonic Testing (UT) Technique Research Group Ultrasonic Testing (UT) Technique Professor Pedro Vilaça * * Contacts: Address: Puumiehenkuja 3 (room 202), 02150 Espoo, Finland pedro.vilaca@aalto.fi October 2017 Contents Historical scope

More information

Non-Destructive Inspection of Composite Wrapped Thick-Wall Cylinders

Non-Destructive Inspection of Composite Wrapped Thick-Wall Cylinders Non-Destructive Inspection of Composite Wrapped Thick-Wall Cylinders Jikai Du, John Feldhacker, Christopher Jerred and Fereidoon Delfanian May 17-19, 2010 Joint Armaments Conference, Exhibition and Firing

More information

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System R. K. Saha, S. Karmakar, S. Saha, M. Roy, S. Sarkar and S.K. Sen Microelectronics Division, Saha Institute of

More information

771. Ultrasonic systems for liquid pulverizer

771. Ultrasonic systems for liquid pulverizer 771. Ultrasonic systems for liquid pulverizer Piotr Vasiljev Vilnius Pedagogical University, Lithuania E-mail: piotr.vasiljev@vpu.lt (Received 11 September 2011; accepted 14 May 2012) Abstract. Analyzing

More information

ULTRASONIC TRANSDUCERS WITH VIBRATING PIEZOELECTRIC PLATES

ULTRASONIC TRANSDUCERS WITH VIBRATING PIEZOELECTRIC PLATES JOURNAL DE PHYSIQUE Colloque C6, supplément au no 11-12, Tome 33, Novembre-Décembre 1972, page 258 ULTRASONIC TRANSDUCERS WITH VIBRATING PIEZOELECTRIC PLATES W. PAJEWSKI Institute of Fundamental Technological

More information

ULTRASOUND. OB/Gyn (Core) Ultrasound PIEZOELECTRIC EFFECT. Principles of Ultrasound Physics and Instrumentation. Nathan Pinkney, BS, CDOS

ULTRASOUND. OB/Gyn (Core) Ultrasound PIEZOELECTRIC EFFECT. Principles of Ultrasound Physics and Instrumentation. Nathan Pinkney, BS, CDOS 1 OB/Gyn (Core) Ultrasound Principles of Ultrasound Physics and Instrumentation Nathan Pinkney, BS, CDOS Philadelphia College of Osteopathic Medicine 2016 ULTRASOUND CATEGORIES OF SOUND INFRASOUND = below

More information

Golden standard for non-invasive body shaping Focused

Golden standard for non-invasive body shaping Focused U Ⅱ Golden standard for non-invasive body shaping Focused Focused pulsed ultrasound for selective fat cell destruction without downtime. U Ⅱ Golden standard for non-invasive body shaping U-Shape II uses

More information

Exam Practice Guide. Units 1 & 2 Physics: Detailed Study 5 - Investigations: Medical physics Examination Questions

Exam Practice Guide. Units 1 & 2 Physics: Detailed Study 5 - Investigations: Medical physics Examination Questions Exam Practice Guide Units 1 & 2 Physics: Detailed Study 5 - Investigations: Medical physics Examination Questions Key Features: 22 original examination style questions on all examinable topics. Full solutions

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60601-2-37 2001 AMENDMENT 1 2004-08 Amendment 1 Medical electrical equipment Part 2-37: Particular requirements for the safety of ultrasonic medical diagnostic and monitoring

More information

Test Procedure for Piezoelectric Accelerometer Ice Thickness Measurement

Test Procedure for Piezoelectric Accelerometer Ice Thickness Measurement 1 of 10 Test Procedure for Piezoelectric Accelerometer Ice Thickness Measurement Revision Date Reviewed By Approved By Summary: This document outlines the function test procedure for a piezoelectric accelerometer

More information

Ultrasound Measurements and Non-destructive Testing Educational Laboratory

Ultrasound Measurements and Non-destructive Testing Educational Laboratory Session 3548 Ultrasound Measurements and Non-destructive Testing Educational Laboratory Vladimir Genis, Horacio Sosa Goodwin College of Professional Studies, Drexel University, Philadelphia, 19104 Emil

More information

Developments in Ultrasonic Inspection II

Developments in Ultrasonic Inspection II Developments in Ultrasonic Inspection II An Ultrasonic Technique for the Testing of Plates Embedded in Concrete with Synthesis of Signals from a Multi-element Probe H. Ishida, Y. Kurozumi, Institute of

More information

Ultrasonic Testing. Basic Principles

Ultrasonic Testing. Basic Principles Ultrasonic Testing Ultrasonic Testing (UT) uses high frequency sound waves (typically in the range between 0.5 and 15 MHz) to conduct examinations and make measurements. Besides its wide use in engineering

More information

Supplement (videos)

Supplement (videos) Supplement (videos) Ruben s tube (sound): http://www.youtube.com/watch?v=gpcquuwqayw Doppler US (diagnostic use): http://www.youtube.com/watch?v=fgxzg-j_hfw http://www.youtube.com/watch?v=upsmenyoju8 High

More information

AK FIXATOR SYSTEM AK1

AK FIXATOR SYSTEM AK1 AK FIXATOR DESCRIPTION AK FIXATOR SYSTEM AK1 UNISORB 'S Model AKII Agile Fixator Mount has been developed specifically to meet industry's demand for a cost effective, truly "agile," machinery installation

More information

The Physics of Ultrasound. The Physics of Ultrasound. Claus G. Roehrborn. Professor and Chairman. Ultrasound Physics

The Physics of Ultrasound. The Physics of Ultrasound. Claus G. Roehrborn. Professor and Chairman. Ultrasound Physics The Physics of Ultrasound Pipe Organ 10-8000 Emission Dog 452-1080 Man 85-1100 Spectrum Bat 10,000-120,000 Porpoise 7000-120,000 Claus G. Roehrborn Professor and Chairman 10 20 Cycles per second Reception

More information

Ultrasonically-assisted Hydrothermal Method for Ferroelectric Material Synthesis

Ultrasonically-assisted Hydrothermal Method for Ferroelectric Material Synthesis Journal of the Korean Physical Society, Vol. 57, No. 4, October 2010, pp. 918 923 Ultrasonically-assisted Hydrothermal Method for Ferroelectric Material Synthesis Ryo Ageba, Yoichi Kadota, Takafumi Maeda,

More information

Ultrasonic Transducer for the Hydrothermal Method

Ultrasonic Transducer for the Hydrothermal Method Journal of the Korean Physical Society, Vol. 57, No. 4, October 2010, pp. 1122 1126 Ultrasonic Transducer for the Hydrothermal Method Peter Bornmann and Tobias Hemsel Mechatronics and Dynamics, University

More information

A micro ultrasonic motor using a micro-machined cylindrical bulk PZT transducer

A micro ultrasonic motor using a micro-machined cylindrical bulk PZT transducer Sensors and Actuators A 127 (2006) 131 138 A micro ultrasonic motor using a micro-machined cylindrical bulk PZT transducer Takefumi Kanda a,, Akira Makino a, Tomohisa Ono a, Koichi Suzumori a, Takeshi

More information

New ultrasonic technologies for food dehydration process intensification

New ultrasonic technologies for food dehydration process intensification PROCEEDINGS of the 22 nd International Congress on Acoustics Sonochemistry and Sonoprocessing: Paper ICA2016-90 New ultrasonic technologies for food dehydration process intensification Roque R. Andrés

More information

APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS

APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS Jeffrey P. Milligan, Daniel T. Peters, Structural Integrity Associates, Inc., USA Many advances in Non-Destructive Examination

More information

Advanced in vitro exposure systems

Advanced in vitro exposure systems Advanced in vitro exposure systems VITROCELL VC 1/7 SMOKING MACHINE Features for e-cigarettes VITROCELL VC 1/7 SMOKING MACHINE Linear smoking machine with high tech features square puff profiles higher

More information

Measurement of Residual Stress in Rails using Ultrasonics

Measurement of Residual Stress in Rails using Ultrasonics Measurement of Residual Stress in Rails using Ultrasonics ICRI Discussion Dr Henry Brunskill henry@pktopk.co.uk www.pktopk.co.uk Contents Introduction. New ultrasonic applications in wheel/rail. Residual

More information

ACOUSTORAPHY Acousto-Optical (AO) Ultrasonics & Its Applications

ACOUSTORAPHY Acousto-Optical (AO) Ultrasonics & Its Applications ACOUSTORAPHY Acousto-Optical (AO) Ultrasonics & Its Applications International Workshop on Imaging NDE April 2007 IGCAR, kalpakkam, India Dr D S Dulay NDT Consultants Limited Middlemarch House, Siskin

More information

Research on Digital Testing System of Evaluating Characteristics for Ultrasonic Transducer

Research on Digital Testing System of Evaluating Characteristics for Ultrasonic Transducer Sensors & Transducers 2014 by IFSA Publishing, S. L. http://www.sensorsportal.com Research on Digital Testing System of Evaluating Characteristics for Ultrasonic Transducer Qin Yin, * Liang Heng, Peng-Fei

More information

Impact of Sound Insulation in a Combine Cabin

Impact of Sound Insulation in a Combine Cabin Original Article J. of Biosystems Eng. 40(3):159-164. (2015. 9) http://dx.doi.org/10.5307/jbe.2015.40.3.159 Journal of Biosystems Engineering eissn : 2234-1862 pissn : 1738-1266 Impact of Sound Insulation

More information

Employer s Unit of Competence Ultrasonic testing of materials, products and plant

Employer s Unit of Competence Ultrasonic testing of materials, products and plant Employer s Unit of Competence Ultrasonic testing of materials, products and plant Document: AA064 Issue 2 May 2016 Image - if cover page required Supported by lead employer Overview This standard identifies

More information

Preamble (disclaimer)

Preamble (disclaimer) Preamble (disclaimer) PHYSICS AND PRINCIPLES OF HEAD/NECK ULTRASOUND Joseph C. Sniezek, MD FACS LTC, MC, USA Otolaryngology/H&N Surgery Tripler Army Medical Center 1. I am not a physicist 2. ACS has recommended

More information

THE DEVELOPMENT AND MANUFACTURE OF FIXED- ULTRASONIC INSPECTION REFERENCE REFLECTORS AND TRANSDUCERS FOR COMPRESSOR BLADE DOVETAILS

THE DEVELOPMENT AND MANUFACTURE OF FIXED- ULTRASONIC INSPECTION REFERENCE REFLECTORS AND TRANSDUCERS FOR COMPRESSOR BLADE DOVETAILS International Workshop SMART MATERIALS, STRUCTURES & NDT in AEROSPACE Conference NDT in Canada 2011 2-4 November 2011, Montreal, Quebec, Canada THE DEVELOPMENT AND MANUFACTURE OF FIXED- ULTRASONIC INSPECTION

More information

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0 The sensor series SONOFLOW CO.55/xxx V2.0 designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a few milliseconds. For applications on

More information

A STUDY ON HIGH FREQUENCY VIBRATION FOR TOOTH EXTRACTION

A STUDY ON HIGH FREQUENCY VIBRATION FOR TOOTH EXTRACTION Volume 119 No. 15 2018, 1507-1512 ISSN: 1314-3395 (on-line version) url: http://www.acadpubl.eu/hub/ http://www.acadpubl.eu/hub/ A STUDY ON HIGH FREQUENCY VIBRATION FOR TOOTH EXTRACTION Hepsiba.D 1 L.D.Vijay

More information

Stress Wave Focusing Transducers

Stress Wave Focusing Transducers UCRL-K-130697 PREPRINT Stress Wave Focusing Transducers Steven R. Visuri, Richard A. London, Luiz Da Silva This paper was prepared for submittal to Optical Society of America, Spring Topical Meetings Orlando,

More information

Simulation study of optical transmission properties of ZnO thin film deposited on different substrates

Simulation study of optical transmission properties of ZnO thin film deposited on different substrates American Journal of Optics and Photonics 2013; 1(1) : 1-5 Published online February 20, 2013 (http://www.sciencepublishinggroup.com/j/ajop) doi: 10.11648/j.ajop.20130101.11 Simulation study of optical

More information

Introduction to Nondestructive Testing

Introduction to Nondestructive Testing Introduction to Nondestructive Testing Outline Introduction to NDT Overview of Six Most Common NDT Methods Selected Applications Definition of NDT The use of noninvasive techniques to determine the integrity

More information

Pulse-Echo Ultrasound Imaging. Resolution in Ultrasound Imaging. Doppler Ultrasound. Resolution vs Penetration. Medical Imaging (EL582/BE620/GA4426)

Pulse-Echo Ultrasound Imaging. Resolution in Ultrasound Imaging. Doppler Ultrasound. Resolution vs Penetration. Medical Imaging (EL582/BE620/GA4426) Medical Imaging (EL582/BE620/GA4426) Pulse-Echo Ultrasound Imaging Ultrasound Imaging Lecture 2 Daniel (Dan) Turnbull, Ph.D. Skirball Institute and Dept of Radiology NYU School of Medicine (daniel.turnbull@med.nyu.edu)

More information

A Study of Applications of Medical Piezoelectrical Ultrasonic Transducer Materials and the Transducers

A Study of Applications of Medical Piezoelectrical Ultrasonic Transducer Materials and the Transducers A Study of Applications of Medical Piezoelectrical Ultrasonic Transducer Materials and the Transducers Quanlu Li *1, Jing Wu 2, Yinhong Zhang 3 School of Physics and Information Technology, Shaanxi Normal

More information

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion Jason Silver August 26, 2009 Presentation Outline Introduction Thesis Objectives Mathematical Model and Principles Methods

More information

Instruction Manual January 2001 PS 10/15 F SERIESTRANSDUCER

Instruction Manual January 2001 PS 10/15 F SERIESTRANSDUCER XPS 10/15 F SERIESTRANSDUCER Instruction Manual January 2001 PS 10/15 F SERIESTRANSDUCER Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect

More information

RLS /M MX SERIES

RLS /M MX SERIES The RLS/M MX series of burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above

More information

Active Thermography Imaging - an Innovative Approach for NDT Inspection

Active Thermography Imaging - an Innovative Approach for NDT Inspection Active Thermography Imaging - an Innovative Approach for NDT Inspection Opgal: Leader in Thermal Imaging Non Destructive Tests Aviation Defense Industrial Security & Safety Mobile 30 Years of Infrared

More information

Available online at ScienceDirect. Physics Procedia 87 (2016 ) 35 41

Available online at   ScienceDirect. Physics Procedia 87 (2016 ) 35 41 Available online at www.sciencedirect.com ScienceDirect Physics Procedia 87 (2016 ) 35 41 44th Annual Symposium of the Ultrasonic Industry Association, UIA 44th Symposium, 20-22 April 2015, Washington,

More information

Proceedings Amorphous SiC/c-ZnO-Based Lamb Mode Sensor for Liquid Environments

Proceedings Amorphous SiC/c-ZnO-Based Lamb Mode Sensor for Liquid Environments Proceedings Amorphous SiC/c-ZnO-Based Lamb Mode Sensor for Liquid Environments Cinzia Caliendo 1, *, Muhammad Hamidullah 1 and Farouk Laidoudi 2 1 Institute of Photonics and Nanotechnologies, IFN-CNR,

More information

RiGO801 Laboratory Requirements

RiGO801 Laboratory Requirements RiGO801 Laboratory Requirements 2015-11-25 Air Conditioning According to EN 13032 1 and LM-79-08 the temperature in the environment of the DUT needs to be 25 C +/- 1 C during the measurement. EN 13032-4

More information

Film Bulk Acoustic Resonator Based on Zinc Oxide Thin Film

Film Bulk Acoustic Resonator Based on Zinc Oxide Thin Film Film Bulk Acoustic Resonator Based on Zinc Oxide Thin Film Roger Ondo Ndong 1,2*, Brice Sorli 2, Alain Giani 2, Alain Foucaran 2 1. Laboratoire pluridisciplinaire des Sciences, LAPLUS, Ecole Normale Supérieure,

More information

Non-Destructive Inspection of Polyethylene Fusions and Electrofusions Dr. Ken Oliphant, P.Eng. and Dalton Crosswell, JANA Corporation

Non-Destructive Inspection of Polyethylene Fusions and Electrofusions Dr. Ken Oliphant, P.Eng. and Dalton Crosswell, JANA Corporation Non-Destructive Inspection of Polyethylene Fusions and Electrofusions Dr. Ken Oliphant, P.Eng. and Dalton Crosswell, JANA Corporation Abstract For buried gas distribution pipelines, the majority of the

More information

An Overview of Ultrasound Testing For Lesion Detection in Human Kidney

An Overview of Ultrasound Testing For Lesion Detection in Human Kidney Journal of Tomography System & Sensors Application Vol.1, Issue 1, June 2018 An Overview of Ultrasound Testing For Lesion Detection in Human Kidney Aina Fadhilah Abd Rahim 1, Zawin Najah Abd Halim 1, Jaysuman

More information

NON-CONTACT ULTRASOUND (NCU)

NON-CONTACT ULTRASOUND (NCU) NON-CONTACT ULTRASOUND (NCU) PHENOMENALLY HIGH EFFICIENCY TRANSDUCERS -- khz to >5.0 MHz Modern ultrasound for materials process analysis, bio-medical, liquid-sensitive materials, sensing, and other applications

More information

DIAGNOSTIC TECHNIQUE OF ABNORMALITIES IN BALL BEARINGS WITH AN ULTRASONIC METHOD

DIAGNOSTIC TECHNIQUE OF ABNORMALITIES IN BALL BEARINGS WITH AN ULTRASONIC METHOD 12 th A-PCNDT 2006 Asia-Pacific Conference on NDT, 5 th 10 th Nov 2006, Auckland, New Zealand DIAGNOSTIC TECHNIQUE OF ABNORMALITIES IN BALL BEARINGS WITH AN ULTRASONIC METHOD Akitoshi Takeuchi 1 1 Kochi

More information

Controlling noise from compressed air systems

Controlling noise from compressed air systems It s been almost a decade since the Control of Noise at Work Act 2005 ¹ was passed, becoming law in April 2006. With the aim of safeguarding workers hearing from excessive noise, this put in place more

More information

FlexiSafe MLCC Termination Device Performance

FlexiSafe MLCC Termination Device Performance FlexiSafe MLCC Termination Device Performance AVX Ltd. Jonathan Lennox Bally Castle Road Coleraine, Northern Ireland BT52 2DA AVX Ron Demcko 3900 Electronics Drive Raleigh, N.C. 27064 The MLCC advantages

More information

CRACK DETECTION AND PIPELINE INTEGRITY SOLUTIONS

CRACK DETECTION AND PIPELINE INTEGRITY SOLUTIONS CRACK DETECTION AND PIPELINE INTEGRITY SOLUTIONS The cornerstones of our success Protecting your assets in our environment Cracks, laminations and pipeline integrity Nature is one of our greatest assets.

More information

Nondestructive testing course structure

Nondestructive testing course structure Nondestructive testing course structure Basic NDT Course Training course objective: Understanding the basic principles of various NDT methods, fundamentals, discontinuities in different product forms,

More information

MODELING USING THE FINITE ELEMENT METHOD OF AN ULTRASONIC STACK USED FOR ULTRASONIC WELDING STAKING PROCESS

MODELING USING THE FINITE ELEMENT METHOD OF AN ULTRASONIC STACK USED FOR ULTRASONIC WELDING STAKING PROCESS SISOM 2011 and Session of the Commission of Acoustics, Bucharest 25-26 May MODELING USING THE FINITE ELEMENT METHOD OF AN ULTRASONIC STACK USED FOR ULTRASONIC WELDING STAKING PROCESS Doru Virgil PĂUŞAN

More information

ULTRASONIC ARRAY APPROACH FOR THE EVALUATION OF ELECTROFUSION JOINTS OF POLYETHYLENE GAS PIPING

ULTRASONIC ARRAY APPROACH FOR THE EVALUATION OF ELECTROFUSION JOINTS OF POLYETHYLENE GAS PIPING ULTRASONIC ARRAY APPROACH FOR THE EVALUATION OF ELECTROFUSION JOINTS OF POLYETHYLENE GAS PIPING H. J. Shin 1, Y. H. Jang 1, J. R. Kwan 2, H. D. Lee 3 1 INDE System Co., Ltd., Suwon, Kyunggi-do, 440-746,

More information

Chapter 1. Principles of medical ultrasound. Overview. Background history: first steps to the piezo-electric effect.

Chapter 1. Principles of medical ultrasound. Overview. Background history: first steps to the piezo-electric effect. Chapter 1 Principles of medical ultrasound GRAHAM ARTHURS, PATRICK HILL AND TREVOR FRANKEL Overview This chapter provides an introduction to the ultrasound process for trainees in anesthesia and other

More information

United Flight 232. Mumbai pipeline tragedy. Bhopal Gas Tragedy

United Flight 232. Mumbai pipeline tragedy. Bhopal Gas Tragedy Importance IfNDT were used here? United Flight 232 Railway accident Mumbai pipeline tragedy Gujrat bridge tragedy Bhopal Gas Tragedy Index 1.Definition 2.Features of NDT 3.Methods of NDT Visual inspection

More information

Spirometry air flow measurement using PVDF Film

Spirometry air flow measurement using PVDF Film Spirometry air flow measurement using PVDF Film Manisha R.Mhetre, H.K.Abhyankar Department of Instrumentation Engineering, Vishwakarma Institute of Technology, Pune - 411037, Maharashtra, India Email:

More information

Inspection of Polyethylene Fusions and Electrofusions

Inspection of Polyethylene Fusions and Electrofusions Abstract Inspection of Polyethylene Fusions and Electrofusions Dr. Ken Oliphant, Dr. Peter Angelo and Patrick Vibien, JANA Corporation Dr. Andy Burns and Dr. Michail Kalloudis, Impact Solutions For buried

More information

Sam Howard PhD Tests & measurements, Onda Corporation. Timothy Demchek PhD - Human tissue heating, Indian State University

Sam Howard PhD Tests & measurements, Onda Corporation. Timothy Demchek PhD - Human tissue heating, Indian State University Should you be using Therapeutic Ultrasound and how can we improve our research Stephen J. Straub PhD, ATC Thanks Lenn Johns PhD - cell biologist, QU Sam Howard PhD Tests & measurements, Onda Corporation

More information

Flip Chips and Acoustic Micro Imaging: An Overview of Past Applications, Present Status, And Roadmap for the Future

Flip Chips and Acoustic Micro Imaging: An Overview of Past Applications, Present Status, And Roadmap for the Future Flip Chips and Acoustic Micro Imaging: An Overview of Past Applications, Present Status, And Roadmap for the Future Janet E. Semmens Sonoscan, Inc. 2149 E. Pratt Boulevard Elk Grove Village, IL 60007 USA

More information

Basic Physics of Ultrasound and Knobology

Basic Physics of Ultrasound and Knobology WELCOME TO UTMB Basic Physics of Ultrasound and Knobology By Daneshvari Solanki, FRCA Laura B. McDaniel Distinguished Professor Anesthesiology and Pain Medicine University of Texas Medical Branch Galveston,

More information

NDT Services Division

NDT Services Division NDT Services Division Teddington Engineered Solutions Ltd. Tel: +44 (0) 870 1166 TES (837) or +44 (0) 1554 744517 Fax: +44 (0) 870 1166 838 or +44 (0) 1554 746435 e-mail: ndt@tes.uk.com Website: www.tes.uk.com/ndt

More information

ZnO Thin Films Generated by Ex-Situ Thermal Oxidation of Metallic Zn for Photovoltaic Applications

ZnO Thin Films Generated by Ex-Situ Thermal Oxidation of Metallic Zn for Photovoltaic Applications Macalester Journal of Physics and Astronomy Volume 4 Issue 1 Spring 2016 Article 12 May 2016 ZnO Thin Films Generated by Ex-Situ Thermal Oxidation of Metallic Zn for Photovoltaic Applications Kovas Zygas

More information

Chapter VI Development of ISFET model. simulation

Chapter VI Development of ISFET model. simulation Chapter VI Development of ISFET model using ZnO as gate and its simulation Introduction Theory of ISFET Experimental work Results and discussion Conclusion 6.1 General: The human bodies ph and electrolyte

More information

LION. Application Note PRECISION. Linear Position Measurement with Eddy-Current Sensors. LA March, Applicable Equipment: Applications:

LION. Application Note PRECISION. Linear Position Measurement with Eddy-Current Sensors. LA March, Applicable Equipment: Applications: LION PRECISION Application Note LA02-0061 March, 2013 Linear Position Measurement with Eddy-Current Sensors Position, Displacement Applicable Equipment: Eddy-Current position measurement systems. Applications:

More information

Ultrathin Piezotronic Transistors with 2-Nanometer Channel Lengths

Ultrathin Piezotronic Transistors with 2-Nanometer Channel Lengths Ultrathin Piezotronic Transistors with 2-Nanometer Channel Lengths Longfei Wang,,,@ Shuhai Liu,,@ Guoyun Gao,, Yaokun Pang,, Xin Yin, & Xiaolong Feng, # Laipan Zhu,, Yu Bai,, Libo Chen,, Tianxiao Xiao,,

More information

Femtosecond Laser Applications in NiTi

Femtosecond Laser Applications in NiTi Femtosecond Laser Applications in NiTi Professor Luísa Coutinho IST-UTL Instituto Superior Técnico, Universidade Técnica de Lisboa, Portugal Objectives Analyze beam/material interaction of femtosecond

More information