NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you!

Size: px
Start display at page:

Download "NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you!"

Transcription

1 Core-Shell Technology NEW Kinetex enyl Biph Biphenyl TM S TM Selectivity that a C8 just can t give you! S Bip he ylhenyl Bnip Remarkable Separation Power Rugged and Reliable % Aqueous Stable

2 Kinetex Core-Shell Advantage Kinetex Core-Shell Technology produces increased efficiencies over traditional, fully porous columns on the market, yielding remarkable chromatographic resolution, higher peak capacities, and greater sensitivity, so labs can get the most out of every HPLC/UHPLC analysis. Kinetex Core-Shell Fully Porous Less Band Broadening More Band Broadening If you are not completely satisfied with Kinetex core-shell columns, send in your comparative data to a similar product with the Kinetex column within days for a FULL REFUND. Phenomenex, Inc. All rights reserved.

3 Core-Shell Technology Introducing the High Performance Kinetex Biphenyl! Biphenyl Transform your reversed phase analysis... pp. - Comprehensive pain panel testing... p. Extended lifetime with biological samples... p. Wide range of Kinetex selectivities... p. 8 Full scalability from HPLC to UHPLC... p. 9 Reproducibility and quality you can rely on... p. Ordering information... p. Phenomenex India Tel: - Fax: - indiainfo@phenomenex.com Web:

4 Transform Your Reversed Phase Analysis Think high performance, enhanced retention, and the ability to go where a traditional C8 can t. The Kinetex Biphenyl offers the high performance benefits of a core-shell particle with a unique stationary phase capable of becoming the go-to selectivity for reversed phase method development. Use Kinetex Biphenyl columns to get enhanced retention, higher sensitivity, and overall better results; especially for aromatic compounds. Mycotoxins Kinetex. µm Biphenyl.e.e.e.e..e.e.e.e. min Waters SunFire. µm C8 8,,, 9, 8,9 Enhanced Retention and Sensitivity min App ID 9 App ID 9 Conditions for all columns: Column: Kinetex. µm Biphenyl Waters SunFire. µm C8 Dimensions: x. mm Mobile Phase: A: mm Ammonium acetate with.% Acetic acid B: Methanol with mm Ammonium acetate with.% Acetic acid Gradient: Time (min) %B Flow Rate:. ml/min Temperature: C Detection: MS/MS (AB SCIEX API ) Sample:. -Acetyldeoxynivalenol. DAS. FB. HT Toxin. FB. T Toxin. Aflatoxin M 8. Aflatoxin G 9. Ochratoxin A. Aflatoxin G. Aflatoxin B. Aflatoxin B Waters and SunFire are registered trademarks of Waters Corporation. Phenomenex is in no way affiliated with Waters Corporation. Comparative separations may not be representative of all applications.

5 Enhanced Separation Power Core-Shell Technology Kinetex Biphenyl is a high efficiency core-shell product capable of adding extra separation power to your analysis of non-polar and polar compounds. Imagine what you could do with this new chromatography solution. Opiate Isomers Kinetex. µm Biphenyl Fused-Core. µm C8.e Impressive Increase in Resolution.e.e.e App ID 99 App ID 99. min. min Conditions for all columns: Column: Kinetex. µm Biphenyl Fused-Core. µm C8 Dimensions: x. mm Mobile Phase: A: Water with. % Formic acid B: Methanol with. % Formic acid Gradient: Time (min)..... %B Customer Example - Polar Therapeutic Drug Kinetex µm Biphenyl vs. Fully Porous µm C8 Flow Rate:. ml/min Temperature: C Detection: MS/MS (AB SCIEX API ) Sample:. Morphine. Hydromorphone. Norhydrocodone C8 Biphenyl ~x Increase in Retention % min Fused-Core is a registered trademark of Advanced Materials Technology, Inc. Phenomenex is in no way affiliated with Advanced Materials Technology, Inc. Comparative separations may not be representative of all applications. Share your Kinetex success stories at: KinetexShare Phenomenex India Tel: - Fax: - indiainfo@phenomenex.com Web:

6 Comprehensive Pain Panel Testing Important methods demand high performance and complete reliability. If a system or column interrupts the flow of samples, time and money can be lost. The new Kinetex Biphenyl ensures that your comprehensive screens display the needed performance with a ruggedness and reliability that will keep you at ease. Pain Panel Screen Kinetex. µm Biphenyl.e.e.8e.e.e.e.e 8.e.e.e.e Full Panel min App ID Find more Clinical applications at: ClinicalApps Conditions for all separations: Column: Kinetex. µm Biphenyl Dimensions: x. mm Part No.: B--Y Mobile Phase: A: Water with. % Formic Acid B: Methanol with. % Formic Acid Gradient: Time (min)..... %B Flow Rate:. ml/min Temperature: C Detection: MS/MS (AB SCIEX API ) Opiates Benzodiazepines Other Drugs of Abuse.e.e. App ID 8 min.e.e.e.e.e.e.e App ID 9 min.e.e.e 8.e.e.e.e App ID min Samples:. Morphine. Oxymorphone. Hydromorphone. Naloxone. Codeine. -MAM. Oxycodone 8. Naltrexone 9. Hydrocodone. Norfentanyl. Tramadol. Normeperidine. Meperidine. Norbuprenorphine. Fentanyl. Buprenorphine. Propoxyphene 8. Norpropoxyphene 9. EDDP. Methadone Samples:. Flurazepam. Midazolam. Lorazepam. Clonazepam. Oxazepam. Hydroxyalprazolam. Nordiazepam 8. Flunitrazepam 9. Temazepam. Alprazolam. Diazepam Samples:. Amphetamine. Methamphetamine. MDA. MDMA. MDEA. Benzoylecgonine. Meprobamate 8. PCP 9. Carisoprodol. Sufentanil

7 Improved Retention of Clinical Samples Core-Shell Technology Pain Panel - Opiates Kinetex. µm Biphenyl Fused-Core. µm C8.e Dramatic Improvement in Retention,e.e,e.e. min App ID 9,e, min App ID 9 Conditions for all columns: Column: Kinetex. µm Biphenyl Fused-Core. µm C8 Dimensions: x. mm Mobile Phase: A: Water with. % Formic acid B: Methanol with. % Formic acid Gradient: Time (min).. %B 9 9 Extended Lifetime with Biological Samples Flow Rate:. ml/min Temperature: C Detection: MS/MS (AB SCIEX API ) Sample:. Morphine. Oxymorphone. Hydromorphone. Naloxone. Codeine. Oxycodone. Naltrexone 8. Hydrocodone 9. Norfentanyl. Tramadol. Normeperidine. Meperidine. Meprobamate. Norbuprenorphine. Fentanyl. Buprenorphine. Carisoprodol 8. Sufentanil 9. Methadone Kinetex Biphenyl Stability in Urine (First injections) Retention Time (min) 8 Injection # 8 Fused-Core is a registered trademark of Advanced Materials Technology, Inc. Phenomenex is in no way affiliated with Advanced Materials Technology, Inc. Comparative separations may not be representative of all applications. -Aminoclonazepam -Aminoflunitrazepam Alprazolam Amphetamine Benzoylecgonine Buprenorphine Clonazepam Codeine Estazolam Flunitrazepam Hydrocodone Hydromorphone Lorazepam MDMA Methadone Midazolam Morphine Norbuprenorphine Nordiazepam Norhydrocodone Oxazepam Temazepam Triazolam Phenomenex India Tel: - Fax: - indiainfo@phenomenex.com Web:

8 Wide Range of Kinetex Selectivities Choose from an extensive selection of phases for greater flexibility in UHPLC/ HPLC method development. Kinetex columns come in a variety of stationary phases to cover a full spectrum of applications ranging from acids and bases, to isomers and extremely polar compounds. Steroids Kinetex. µm Biphenyl Kinetex. µm C8 Kinetex. µm XB-C8 8 9 min 9 min App ID 9 App ID 98 App ID 99 Conditions for all columns: Column: Kinetex. µm Biphenyl Kinetex. µm C8 Kinetex. µm XB-C8 Kinetex. µm Phenyl-Hexyl Dimensions: x. mm Mobile Phase: A: Water B: Acetonitrile Gradient: to % B in minutes Flow Rate:.8 ml/min Temperature: C Detection: nm Samples:. Estriol. Hydrocortisone. Prednisone. Cortisone. Corticosterone. β-estradiol. Cortisone Acetate 8. -Hydroxyprogesterone 9. -Hydroxyprogesterone. Deoxycorticosterone min Kinetex. µm Phenyl-Hexyl 9 8 App ID 9 min Take your pick from six stationary phases! Phase Selectivity Kinetex Biphenyl Excellent reversed phase and aromatic retention and selectivity Kinetex C8 General hydrophobic selectivity and increased retention of polar basic compounds Kinetex XB-C8 Excellent hydrophobic selectivity and increased retention of polar acidic compounds Kinetex C8 Less hydrophobic than a C8 phase Kinetex Phenyl-Hexyl Greater retention and separation of aromatic hydrocarbons Kinetex HILIC Increased polar retention under HILIC conditions Want more? - Applications - Development tips - Method comparisons Request your full Kinetex product guide at: KinetexRequest 8

9 Full Scalability from HPLC to UHPLC With four fully scalable particle sizes, Kinetex Core-Shell Technology allows you to easily develop and transfer methods to and from any LC platform you choose. Kinetex. µm and. µm Biphenyl are coming soon! Core-Shell Technology Kinetex µm C8 µm or better efficiencies at µm pressures for HPLC and PREP LC methods µm App ID min Kinetex. µm C8 Achieve sub- µm performance on HPLC and UHPLC systems. µm App ID min Kinetex. µm C8 % higher efficiency than fully porous. µm columns. µm App ID min Kinetex. µm C8 Incredible UHPLC efficiency and performance gains. µm App ID min * Gingerols analyzed on x. mm columns. Phenomenex India Tel: - Fax: - indiainfo@phenomenex.com Web: 9

10 Reproducibility and Quality You Can Rely On Your time and energy is incredibly important and should never be spent on issues with column irreproducibility. While other manufacturers skimp on quality, Phenomenex has and always will take extra steps to ensure that you get the highest quality products, each and every time. Trust us. We are overwhelmingly passionate when it comes to making sure our products live up to the standards that you demand. Batch-to-Batch Reproducibility Drugs of Abuse - Kinetex. µm Biphenyl.e.e.e 8.e.e.e.e Batch App ID % Aqueous Stable Amphetamine - Initial Injection.e.e.e App ID 98 min min Amphetamine - Final Injection.e.e.e Batch 8.e After hr storage in % water 8.e.e.e.e App ID.e.e App ID 98 min min.e.e.e 8.e.e.e.e Batch App ID Conditions for above separations: Column: Kinetex. µm Biphenyl Dimensions: x. mm Part No.: B--AN Mobile Phase:. % Formic Acid in Water Flow Rate:. ml/min Injection Volume: µl Temperature: C Detection: MS (AB SCIEX API ) Sample: Amphetamine ( ng/ml) min * Conditions for this test can be found on page.

11 Extend Your Column Lifetime R&D Award Recipient Protect your Kinetex core-shell columns and other UHPLC columns from damaging contaminants and microparticulates with the SecurityGuard ULTRA guard cartridge system. Easy to use Extends column lifetime Pressure rated to, psi (,8 bar) From Injector SecurityGuard ULTRA UHPLC Column to Detector Cartridge* Holder Frit Compounds of Interest Material Chamber Contaminants and Particulates UHPLC Column Protection *Cartridge schematic not drawn to scale See it in action at: Ordering Information Kinetex core-shell columns come in a variety of phases, dimensions, and particle sizes. Visit for more info. Kinetex. µm Columns (mm) SecurityGuard ULTRA Cartridges SecurityGuard ULTRA Cartridges SecurityGuard ULTRA Cartridges Phases x. x. /pk x. /pk x. x. x. /pk Biphenyl B--AN D--AN AJ-99 B--Y AJ-98 B--E D--E F--E AJ-9 for. mm ID for. mm ID for. mm ID Kinetex µm Columns (mm) SecurityGuard ULTRA Cartridges SecurityGuard ULTRA Cartridges SecurityGuard ULTRA Cartridges Phases x. /pk x. /pk x. x. x. x. /pk Biphenyl B--AN AJ-99 B--Y AJ-98 B--E D--E F--E G--E AJ-9 for. mm ID for. mm ID for. mm ID SecurityGuard ULTRA cartridges require holder, Part No. AJ-9. Terms and Conditions Phenomenex reserves the right to refuse sale at its discretion. Subject to Phenomenex Standard Terms & Conditions, which may be viewed at Trademarks Phenomenex, SecurityGuard and Kinetex are trademarks of Phenomenex. SunFire and Waters are registered trademarks of Waters Corporation. API, API, and API are trademarks of AB SCIEX Pte. Ltd. Fused-Core is a registered trademark of Advanced Materials Technology, Inc. Disclaimer Phenomenex is not affiliated with Advanced Materials Technology, Inc. or Waters Corporation. Comparative separations may not be representative of all applications. Phenomenex, Inc. All rights reserved. Phenomenex India Tel: - Fax: - indiainfo@phenomenex.com Web:

12 NEW Kinetex Biphenyl Biphenyl enyl Selectivity that a C8 just can t give you! Biphenyl Australia t: -98- f: -98- auinfo@phenomenex.com Austria t: -9- f: -9- anfrage@phenomenex.com Belgium t: (French) t: 8 (Dutch) f: + ()-89 beinfo@phenomenex.com Canada t: (8) -8 f: () 8-8 info@phenomenex.com Denmark t: 8 88 f: + 8 nordicinfo@phenomenex.com Finland t: 9 89 f: + 8 nordicinfo@phenomenex.com France t: 9 f: 9 franceinfo@phenomenex.com Germany t: -88- f: -88- anfrage@phenomenex.com India t: - f: - indiainfo@phenomenex.com Ireland t: f: + -9 eireinfo@phenomenex.com Italy t: f: italiainfo@phenomenex.com Luxembourg t: + ()-8 f: + ()-89 nlinfo@phenomenex.com Mexico t: f: tecnicomx@phenomenex.com The Netherlands t: -8 f: -89 nlinfo@phenomenex.com New Zealand t: 9-89 f: 9-89 nzinfo@phenomenex.com Norway t: 8 f: + 8 nordicinfo@phenomenex.com Puerto Rico t: (8) -HPLC f: () 8-8 info@phenomenex.com Sweden t: 8 9 f: + 8 nordicinfo@phenomenex.com United Kingdom t: - f: -9 ukinfo@phenomenex.com United States t: () - f: () 8-8 info@phenomenex.com All other countries: Corporate Office USA t: () - f: () 8-8 info@phenomenex.com BR8_in Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com

PAIN PANEL. Research and Solutions

PAIN PANEL. Research and Solutions PAIN PANEL Research and Solutions Pain management drug use and abuse has increased significantly in recent years. The 21 National Survey on Drug Use & Health (NSDUH) reports that 17.3% of first-time drug

More information

METHAMPHETAMINE & AMPHETAMINE

METHAMPHETAMINE & AMPHETAMINE METHAMPHETAMINE & AMPHETAMINE Enantiomers from Urine Rapid and Accurate Chiral Separation Polysaccharide Chiral Chiral LC LC Columns and SFC PHEN-RUO-49 Revision: Lux 3 µm AMP Column High Efficiency LC/MS/MS

More information

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns. For Far Greater UHPLC Column Performance... You Must Have Kinetex Core-Shell UHPLC Columns www.phenomenex.com/kinetex The UHPLC Core-Shell Advantage Kinetex Core-Shell Technology produces increased efficiencies

More information

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns Core-Shell Technology 11 HPLC Myths Uncovered & Why You Must Have Kinetex Core-Shell HPLC Columns 2.6 www.phenomenex.com/kinetex HPLC myths have been around since the early 19 s! From the one about the

More information

PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes

PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes Application Guide PAIN PANEL Screen 41 compounds in under 4 minutes Solutions for large compound screens and individual compound classes such as benzodiazepines, opiates, and more Achieve resolution of

More information

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market Better UHPLC Performance Starts NW.7 µm Core-Shell * Columns The IRST and NLY sub- µm core-shell columns on the market Phenomenex India Laxmi Cyber City, Ground loor, B Block, Survey no: Kondapur, Hyderabad

More information

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology. Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology Jeff Layne, Phenomenex, Inc. Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 951 USA With virtually

More information

Finally, a Solid Phase Extraction product for Drugs of Abuse

Finally, a Solid Phase Extraction product for Drugs of Abuse n io t c a r t x E e s a h P d li Finally, a So e s u b A f o s g u r D r fo product Imagine Only Needing 1 SPE Sorbent For All of Your Drugs of Abuse Extractions Extract over 11 drugs using the same sorbent

More information

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs. Table 1. List of pain panel drugs

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs. Table 1. List of pain panel drugs APPLICATION Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs Seyed Sadjadi, Shahana Huq, Sean Orlowicz, and Laura Snow Phenomenex, 4 Madrid Avenue, Torrance,

More information

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse Keep It Clean Solid Phase Extraction Solutions for Drugs of Abuse Analysis Neutral Drugs of Abuse Basic Drugs of Abuse Strata -X-Drug B: Basic Drugs of Abuse Working with basic drugs? Here are 3 reasons

More information

Core-Shell Technology for Proteins and Peptides

Core-Shell Technology for Proteins and Peptides Core-Shell Technology for Proteins and Peptides Better BioSeparations on HPLC and UHPLC Systems www.phenomenex.com/aeris Aeris Core-Shell Technology Core-Shell Particles Precision Engineered for Protein

More information

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS Introduction Drug analysis from whole blood is gaining popularity due to a more complete measurement

More information

Preparative Chromatography Meets UHPLC

Preparative Chromatography Meets UHPLC Preparative Chromatography Meets UHPLC The Power of Kinetex Core-Shell Technology with the Performance of Piston Packed Prep Columns Ultra-High Efficiencies Ultra-Long Lifetimes NO Added Pressure Two Award

More information

APPLICATION TN Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns

APPLICATION TN Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns APPLICATION Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns Sean Orlowicz Manager, PhenoLogix When not in the lab, Sean

More information

APPLICATIONS TN Analytical Method

APPLICATIONS TN Analytical Method APPLICATIONS Simultaneous Determination of Antidepressants and Metabolites in Urine Using Ultra-High Performance Liquid Chromatography Tandem Mass Spectrometry (UHPLC-MS/MS) using a Kinetex Core-Shell

More information

Labs Across the World Are Advancing Their Protein Precipitation

Labs Across the World Are Advancing Their Protein Precipitation Phospholipid Removal Solutions Labs Across the World Are Advancing Their Protein Precipitation Achieve Cleaner Samples Extend HPLC Column Lifetime Improve Analyte Sensitivity Reduce Mass Spec Maintenance

More information

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Michael McGinley, Deborah Jarrett, and Jeff Layne Phenomenex, Inc., 411 Madrid Avenue, Torrance, CA 91 USA Aeris WIDEPORE

More information

Strata-X- NEW! Drug B. Drug B Plus for In-Well Hydrolysis. Simplify Your Solid Phase Extraction.

Strata-X- NEW! Drug B. Drug B Plus for In-Well Hydrolysis. Simplify Your Solid Phase Extraction. Polymeric SPE Strata-X- Drug B Simplify Your Solid Phase Extraction QC Tested for Drugs of Abuse No Equilibration or Conditioning Required NEW! Drug B Plus for In-Well Hydrolysis www.phenomenex.com/strataxdrug

More information

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced SIMPLIFIED IRAL SEPARATIS Lux ellulose- Guaranteed Alternative to IRALEL D- Exceptional Quality Sensibly Priced Lux ellulose- ellulose tris(3,5-dimethylphenylcarbamate) This dimethyl cellulose selector

More information

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1 APPLICATIONS A Comparison of Various Kinetex C18 Phases Zeshan Aqeel and Jeff Layne Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA Introduction When performing reversed phase LC separations, there

More information

Validation of an Automated Method to Remove

Validation of an Automated Method to Remove Shahana Wahab Huq 1, Richard Thomas 2, Agnes Cua 2, Seyed Sadjadi 1 1 Phenomenex, 411 Madrid Avenue, Torrance, CA 951 2 Precision Toxicology, 33 Bunker Hill Street, San Diego, CA 9219 Validation of an

More information

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit Kinetex 5 µm Core-Shell Columns Deliver Significant Improvements in Chromatographic Efficiency and Resolution versus Traditional Fully Porous 5 µm Columns Philip J. Koerner and Jeff Layne Phenomenex, Inc.,

More information

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology Determination of Impurities and Related Substances for Acetylsalicylic Acid (Ph. Eur. Monograph 9): Increased Sensitivity and Resolution, Faster Analysis, and Reduced Solvent Usage Using Kinetex 2.6 µm

More information

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1. APPLICATIONS A Simple and Effective High ph LC/MS/MS Method for Determination of Underivatized Vitamin B1 and B6 in Human Whole Blood Ramkumar Dhandapani Technical Manager Ramkumar loves to write poems,

More information

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD Determination of Sugars in Animal Feed using HPLC-ELSD Laura Snow, Zeshan Aqeel, Allen Misa and Scott Krepich Phenomenex, Inc., Madrid Ave., Torrance, CA 9050 USA Laura Snow Scientist- Phenologix Outside

More information

Yes You Can! New! Amazing EVO C18. Core-Shell Technology

Yes You Can! New! Amazing EVO C18. Core-Shell Technology Core-Shell Technology Yes You Can! New! Amazing EVO C8 Develop robust methods from ph - Get improved peak shape for bases Easily reduce run times and increase sensitivity THE PAST Fully Porous You used

More information

Protect Your Mass Spec

Protect Your Mass Spec Protect Your Mass Spec Sample Preparation Solutions for Biological Samples www.phenomenex.com/bioms Dirty Samples Could be Costing You Money and Sensitivity Biological samples contain a wide variety of

More information

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs Seyed Sadjadi, Shahana Huq, Sean Orlowicz and Laura Snow Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis

More information

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns Shuguang Li, Sky Countryman, and Erica Pike Phenomenex,

More information

Phospholipid Removal Solutions

Phospholipid Removal Solutions Remove Phospholipids Remove Protein No Method Development www.phenomenex.com/phree One Quick Method, Three Big Advantages 1 2 Remove Proteins that can clog HPLC columns Eliminate Phospholipids that cause

More information

Rapid and Sensitive Analysis of a 93-Compound Forensic Panel in Urine using the QTRAP /Triple Quad 4500 LC- MS/MS System

Rapid and Sensitive Analysis of a 93-Compound Forensic Panel in Urine using the QTRAP /Triple Quad 4500 LC- MS/MS System Rapid and Sensitive Analysis of a 93-Compound Forensic Panel in Urine using the QTRAP /Triple Quad 4500 LC- MS/MS System Xiang He, 1 Casey Burrows 1, Matthew Noestheden 2, Michael Jarvis, 2 Adrian Taylor,

More information

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases T-1164 APPLICATIS Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases Marc Jacob, Liming Peng, Michael Klein, Tom eveland,

More information

LCMS-8050 Drugs of Abuse: 113 Analytes with Polarity Switching

LCMS-8050 Drugs of Abuse: 113 Analytes with Polarity Switching Liquid Chromatography Mass Spectrometry SSI-LCMS-8 LCMS-8 Drugs of Abuse: Analytes with Polarity Switching LCMS-8 Summary Seventy six analytes and their internal standards are described below. Multiple

More information

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite T-1154 APPLICATIS Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS Matthew Trass, Shahana Huq, Seyed Sadjadi, Sky Countryman and Zdravko

More information

A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography

A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography Application Note LCMS-109 A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography Time of Flight (LC-TOF) Mass Spectrometry Introduction Many clinical

More information

APPLICATIONS TN Materials and Methods

APPLICATIONS TN Materials and Methods APPLICATIONS A Simple, Fast, and Efficient HPLC Method for Sensitive, Accurate, and Reproducible Quantitation of Vitamin C in Human Plasma by Applying Impact Protein Precipitation Plate Technology with

More information

1/27/ New Release, Quest Diagnostics Nichols Institute, Valencia

1/27/ New Release, Quest Diagnostics Nichols Institute, Valencia NEW TESTS Please Note: Not all test codes assigned to each assay are listed in the table of contents. Please refer to the complete listing on the page numbers indicated. Test Code Test Name Effective Date

More information

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology Core-Shell Technology Kinetex EVO C8 HPLC/UHPLC Core-Shell Columns Greater Polar Retention with % Aqueous Stability Robust Methods from ph - Improved Peak Shape for Bases NEW.7 µm NEW. µm µm Unconventionally

More information

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput ULTIMATE HPLC/UHPLC CMB Kinetex Luna mega Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput NEW MEGA Core-Shell Technology Luna mega Luna mega PS Kinetex. Kinetex Luna mega Cutting

More information

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine High-Throughput Quantitative LC-MS/MS Analysis of and 14 Benzodiazepines in Urine Bill Yu, Kristine Van Natta, Marta Kozak, Thermo Fisher Scientific, San Jose, CA Application Note 588 Key Words Opiates,

More information

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE Aeris Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations Aeris is a specialized line of reversed phase core-shell UHPLC columns, built exclusively for the ultra-high performance

More information

E XCEL LENCE JUST GOT BETTER UCT FORENSICS CLEAN SCREEN XCEL SPE COLUMNS

E XCEL LENCE JUST GOT BETTER UCT FORENSICS CLEAN SCREEN XCEL SPE COLUMNS FORENSICS UCT E XCEL LENCE JUST GOT BETTER CLEAN SCREEN XCEL SPE COLUMNS CLEAN SCREEN XCEL COLUMNS EXTRACTION OF BASIC DRUGS AND METABOLITES FROM URINE/ BLOOD USING SPE CARTRIDGES 130mg Clean Screen Xcel

More information

Agilent Clinical LC/MS: Review of Established LC-MS QQQ Clinical Research Applications. dr. Jan Srbek, HPST. Page 1

Agilent Clinical LC/MS: Review of Established LC-MS QQQ Clinical Research Applications. dr. Jan Srbek, HPST. Page 1 Agilent Clinical LC/MS: Review of Established LC-MS QQQ Clinical Research Applications dr. Jan Srbek, HPST Page 1 Major LC-MS Clinical Applications Steroids/Endocrinology Vitamin D Testosterone, Estradiol

More information

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS TECHNICAL NOTE 21883 Fast and easy separation of 23 drugs of abuse including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS Authors Kean Woodmansey 1, Jon Bardsley 1 and Stacy

More information

Figure 1. Core-Shell Particle Technology

Figure 1. Core-Shell Particle Technology Purification of Chlorogenic cid from Green Coffee using Kinetex Core-Shell Technology in xia Preparative Formats Zeshan qeel Technical Magician Zeeshan loves to collect watches and the ack to the Future

More information

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS A Comprehensive Method for the Analysis of Pain Management Drugs and Drugs of Abuse Incorporating Simplified, Rapid Mixed-Mode SPE with UPLC-MS/MS for Clinical Research Jonathan P. Danaceau, Scott Freeto,

More information

APPLICATION TN Materials and Methods Reagents and Chemicals

APPLICATION TN Materials and Methods Reagents and Chemicals TN-8 APPLICATION Fast Analysis of Sucrose,, and Composition in Fruit Juices and Processed Beverages using Simplified HPLC Methodology Brian Rivera Product Manager In addition to chromatography, Brian also

More information

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE)

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE) APPLICATIONS A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE) Ann Montross Technical Specialist Ann enjoys cooking/baking and roasting her

More information

LC Application Note. Dangerous driver?

LC Application Note. Dangerous driver? LC Application Note Dangerous driver? www.palsystem.com Dangerous driver? Robert M. Sears 1 ; Kenneth C. Lewis 2 ; and Kim Gamble 3 1 SC Law Enforcement Division, Columbia, SC 29221; 2 OpAns LLC, Durham

More information

Ultra-Fast Forensic Toxicological Screening and Quantitation under 3 Minutes using SCIEX X500R QTOF System and SCIEX OS 1.

Ultra-Fast Forensic Toxicological Screening and Quantitation under 3 Minutes using SCIEX X500R QTOF System and SCIEX OS 1. Ultra-Fast Forensic Toxicological Screening and Quantitation under 3 Minutes using SCIEX X500R QTOF System and SCIEX OS 1.0 Software Xiang He 1, Adrian M. Taylor 2, Michael Jarvis 2 and Alexandre Wang

More information

Using Liquid Chromatography Tandem Mass Spectrometry Urine Drug Testing to Identify Licit and Illicit Drug-Use in a Community-based Patient Population

Using Liquid Chromatography Tandem Mass Spectrometry Urine Drug Testing to Identify Licit and Illicit Drug-Use in a Community-based Patient Population Using Liquid Chromatography Tandem Mass Spectrometry Urine Drug Testing to Identify Licit and Illicit Drug-Use in a Community-based Patient Population Adam S. Ptolemy 1, Colleen Murray 2, Edward Dunn 3,

More information

NEW Kinetex F5. HPLC/UHPLC Core-Shell Columns

NEW Kinetex F5. HPLC/UHPLC Core-Shell Columns Core-Shell Technology NEW Kinetex Whoa! I can even separate structural isomers! TMS TMS HPLC/UHPLC Core-Shell Columns Reduce Method Development Time by Days Greater Reproducibility than other PPs Glorious

More information

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB:

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB: Exceed your Purification Goals Guaranteed The Axia Prep Column Advantage Extended column lifetime Reproducibility: column-to-column and batch-to-batch igher efficiency Improved peak shape Increased loadability

More information

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex.6 µm Core-Shell Technology Column Philip J. Koerner, Matthew Trass, and Jeff Layne Phenomenex, Inc., Madrid Ave.,

More information

Biphenyl. Stationary Phase: Fast, Rugged Raptor Columns with Time-Tested Selectivity. Pure Chromatography. Selectivity Accelerated

Biphenyl. Stationary Phase: Fast, Rugged Raptor Columns with Time-Tested Selectivity. Pure Chromatography. Selectivity Accelerated Fast, Rugged Raptor Columns with Time-Tested Selectivity Selectivity Accelerated Stationary Phase: Biphenyl CH 3 Si CH 3 O Pure Chromatography www.restek.com/raptor The Raptor Biphenyl Column With Raptor

More information

Fully Automated Online Sample Preparation and LC-MS/MS Analysis of Drugs of Abuse in Oral Fluids

Fully Automated Online Sample Preparation and LC-MS/MS Analysis of Drugs of Abuse in Oral Fluids PO-CON1753E Fully Automated Online Sample Preparation and LC-MS/MS Analysis of Drugs of Abuse in Oral Fluids ASMS 2017 TP-442 Joshua F. Emory 1, Nathan DeFreitas 2, Michael Roberts 1, Manoj Tyagi 2, M.

More information

Alcohol Biomarkers by UHPLC-MS/MS

Alcohol Biomarkers by UHPLC-MS/MS Alcohol Biomarkers by UHPLC-MS/MS Application #AN9 ACE Excel. C8 x. mm EXL--U A: mm ammonium fluoride B: MeCN....... ml/ µl C AB SCIEX triple quad Negative ESI MRM Source temperature: C IonSpray voltage:

More information

Core-Shell Technology. Kinetex. Columns. The chosen core-shell brand to drive UHPLC performance to the next level. Core-Shell Technology

Core-Shell Technology. Kinetex. Columns. The chosen core-shell brand to drive UHPLC performance to the next level. Core-Shell Technology Kinetex. µm UHPLC Coumns The chosen core-she brand to drive UHPLC performance to the next eve Simpy Advantageous The band broadening (wide peaks) and engthy retention times of traditiona fuy porous products

More information

Proof of Concept for Automated SPE/HPLC/MS/MS Methods to Replace Traditional Immunoassay with MS Confirmation of Driving Under the Influence Samples

Proof of Concept for Automated SPE/HPLC/MS/MS Methods to Replace Traditional Immunoassay with MS Confirmation of Driving Under the Influence Samples Proof of Concept for Automated SPE/HPLC/MS/MS Methods to Replace Traditional Immunoassay with MS Confirmation of Driving Under the Influence Samples Robert M. Sears, Toxicology Technical Leader 1, Kenneth

More information

3703 Camino del Rio South 100-A San Diego, CA, Phone Fax CLIA# 05D years

3703 Camino del Rio South 100-A San Diego, CA, Phone Fax CLIA# 05D years Drug Adherence Assessment Report CleanAssure TM (DRIED BLOOD SPOT): Detection Range see NOTES. Prescribed Medications: NO MEDICATION LIST PROVIDED CONSISTENT RESULTS - MEDICATION DETECTED (PARENT DRUG

More information

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column Clinical, Forensic & Toxicology Applications 4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column By Amanda Rigdon Abstract A rapid, sensitive method

More information

Opiates, Opioids and Benzodiazepines, Amphetamines & Illicit Drug Forensic Analysis by LC/MS

Opiates, Opioids and Benzodiazepines, Amphetamines & Illicit Drug Forensic Analysis by LC/MS Opiates, Opioids and Benzodiazepines, Amphetamines & Illicit Drug Forensic Analysis by LC/MS Julie Cichelli, PhD Agilent Technologies Application Engineer April 29, 2014 Agenda A method for the rapid analysis

More information

Keep it Clean with Strata -X

Keep it Clean with Strata -X Simplified Solid Phase Extraction Solutions Neutral Compounds Acidic Compounds Basic Compounds Strong Acids (pk a < 2 Weak Acids (pk a 2-4 Neutral Compounds Weak Bases (pk a 8-10 Strong Bases (pk a > 10

More information

3703 Camino del Rio South 100-A San Diego, CA, Phone Fax CLIA# 05D Director: David J.

3703 Camino del Rio South 100-A San Diego, CA, Phone Fax CLIA# 05D Director: David J. Drug Adherence Assessment Report Prescribed Medications: NO MEDICATION LIST PROVIDED CONSISTENT RESULTS - REPORTED MEDICATION DETECTED (PARENT DRUG AND/OR METABOLITE) REPORTED PRESCRIPTION FLAG ANTICIPATED

More information

Pain Management and Compliance Toxicology. Greg Jellick, MSFS, D-ABFT-FT Technical Director Quality Toxicology San Antonio, TX

Pain Management and Compliance Toxicology. Greg Jellick, MSFS, D-ABFT-FT Technical Director Quality Toxicology San Antonio, TX Pain Management and Compliance Toxicology Greg Jellick, MSFS, D-ABFT-FT Technical Director Quality Toxicology San Antonio, TX Prescription Drug Abuse: A National Problem Prescription drug abuse is a growing

More information

Drugs of Abuse in Oral Fluids: Automated SPE Extraction and LC/MS/MS Determination using a Robotic Autosampler

Drugs of Abuse in Oral Fluids: Automated SPE Extraction and LC/MS/MS Determination using a Robotic Autosampler Drugs of Abuse in Oral Fluids: Automated SPE Extraction and LC/MS/MS Determination using a Robotic Autosampler Fred D. Foster 1, John R. Stuff 1, Jacqueline A. Whitecavage 1, Edward A. Pfannkoch 1, Mark

More information

The Drug Testing Process. Employer or Practice

The Drug Testing Process. Employer or Practice Disclosures Clinical Professor, Jefferson Medical College BOD MROCC [Medical Review Officer Certification Council] BOD National Sleep Foundation BOD POEMS [Pennsylvania Occupational & Environmental Medicine

More information

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W Simple, Fast and Accurate Quantitation of Human Plasma Vitamins and Their Metabolites by Protein Precipitation Combined with Columns Using HPLC-UV, HPLC-FLD or LC/MS/MS Shuguang Li, Jason Anspach, Sky

More information

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency

More information

Rapid LC/TOF MS for Analytical Screening of Drugs in the Clinical Research Lab

Rapid LC/TOF MS for Analytical Screening of Drugs in the Clinical Research Lab Application Note Clinical Research Rapid LC/TOF MS for Analytical Screening of Drugs in the Clinical Research Lab Authors Adam Barker 1,2, Frederick G. Strathmann 3, Natalie N. Rasmussen 4, and Carrie

More information

Supported Liquid Extraction (SLE) For Food Applications

Supported Liquid Extraction (SLE) For Food Applications Supported Liquid Extraction (SLE) For Food Applications Novum Synthetic SLE Unique, Synthetic Sorbent that Provides Consistent, Reliable Results Strata DE Diatomaceous Earth SLE Cost-Effective, Guaranteed

More information

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations For Research Use Only. Not for use in diagnostic procedures. 1 2015 AB Sciex RUO-MKT-11-1018-A For research

More information

September HCMC Toxicology Transition: Additional information and Frequently Asked Questions

September HCMC Toxicology Transition: Additional information and Frequently Asked Questions September 2016 HCMC Toxicology Transition: Additional information and Frequently Asked Questions Many clinicians have asked for more information about the Urine Drug Compliance Analysis (LAB8742) switch

More information

An Easier QuEChERS Solution for Diverse Matrices. Learn more at

An Easier QuEChERS Solution for Diverse Matrices. Learn more at An Easier QuEChERS Solution for Diverse Matrices Learn more at www.phenomenex.com/roq What is roq QuEChERS? QuEChERS is a descriptive acronym that stands for Quick, Easy, Cheap, Effective, Rugged, and

More information

Confidence. A New Standard of. Calibration, Surrogate, & Internal Standards for Environmental Analysis

Confidence. A New Standard of. Calibration, Surrogate, & Internal Standards for Environmental Analysis A New Standard of Confidence Calibration, Surrogate, & Internal Standards for Environmental Analysis Meets ISO/IEC 17025 & ISO Guide 34 Criteria Stay in Calibration Longer Lot-to-Lot Consistency ACCREDITED

More information

Laboratory Testing to Support Pain Management: Methods, Concepts and Case Studies

Laboratory Testing to Support Pain Management: Methods, Concepts and Case Studies Laboratory Testing to Support Pain Management: Methods, Concepts and Case Studies Frederick G. Strathmann, PhD, DABCC, (CC,TC) Medical Director, Toxicology Associate Scientific Director of MS ARUP Laboratories

More information

Determination of 78 Banned or Controlled Racing Industry Drugs in Horse Urine Using SPE and LC-MS/MS

Determination of 78 Banned or Controlled Racing Industry Drugs in Horse Urine Using SPE and LC-MS/MS Determination of 78 Banned or Controlled Racing Industry Drugs in Horse Urine Using SPE and LC-MS/MS UCT Part Numbers XRDAH203 Gravity Flow XtrackT DAU 200 mg, 3 ml column SPHPHO6001-5 Select ph Buffer

More information

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine J. Jones, S. Westwood, T. Liddicoat, L. Pereira, T. Edge Thermo Fisher Scientific, Manor Park, Runcorn, UK Overview Purpose:

More information

INTERPATH LABORATORY, INC. TEST UPDATES

INTERPATH LABORATORY, INC. TEST UPDATES EFFECTIVE DATE: February 16, 2016 INTERPATH LABORATORY, INC. TEST UPDATES Please take note of the following test updates and make the appropriate changes in your Interpath Service Manual. Feel free to

More information

Oral Fluid Drugs of Abuse Testing

Oral Fluid Drugs of Abuse Testing Solutions at Work Oral Fluid Drugs of Abuse Testing Volume indicator turns blue when collection is complete (average 3 minutes) Non-invasive collection test anytime, anywhere Directly observed, no gender

More information

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases Phenyl-Hexyl UHPLC Columns lternate, complementary selectivity to A C8 and C8 bonded phases articularly recommended for P compounds containing aromatic groups xcellent bonded phase stability for E durable,

More information

New Luna Omega. Columns. The Final Word in Fully Porous UHPLC

New Luna Omega. Columns. The Final Word in Fully Porous UHPLC New Luna Omega 1.6 µm UHPLC Coumns The Fina Word in Fuy Porous UHPLC Enhanced with 2 Years of Technoogy, Innovation, and Experience One of the word s eading HPLC brands, now enhanced for incredibe UHPLC

More information

ORAL FLUID AS A CHEMICAL TEST FOR THE DRE PROGRAM : HISTORY, THE FUTURE, AND PRACTICAL CONSIDERATIONS

ORAL FLUID AS A CHEMICAL TEST FOR THE DRE PROGRAM : HISTORY, THE FUTURE, AND PRACTICAL CONSIDERATIONS ORAL FLUID AS A CHEMICAL TEST FOR THE DRE PROGRAM : HISTORY, THE FUTURE, AND PRACTICAL CONSIDERATIONS Barry K Logan PhD, DABFT National Director of Forensic Services, NMS Labs Willow Grove PA Disclaimer

More information

3703 Camino del Rio South 100-A San Diego, CA, Phone Fax CLIA# 05D years

3703 Camino del Rio South 100-A San Diego, CA, Phone Fax CLIA# 05D years Drug Adherence Assessment Report CleanAssure TM (DRIED BLOOD SPOT): Detection Range see NOTES. Prescribed Medications: HYDROMORPHONE (DILAUDID, EXALGO), CYCLOBENZAPRINE (FLEXERIL), METHADONE (METHADOSE),

More information

Vitamin Testing APPLICATIONS GUIDE

Vitamin Testing APPLICATIONS GUIDE Vitamin Testing APPLICATIONS GUIDE Vitamins play an essential role in human health and wellness. While essential, many vitamins cannot be synthesized within the body and must be obtained externally, most

More information

Validation Report for the Neogen Fentanyl Kit for ELISA Screening of Whole Blood and Urine Specimens

Validation Report for the Neogen Fentanyl Kit for ELISA Screening of Whole Blood and Urine Specimens Validation Report for the Neogen Fentanyl Kit for ELISA Screening of Whole Blood and Urine Specimens This document describes the validation of a Neogen Fentanyl kit for the semi-quantitative analysis of

More information

APPLICATIONS TN Rapid, High Resolution Analysis of Aflatoxin Extracts from Peanut Butter Using Kinetex Core-Shell Technology and Strata SPE

APPLICATIONS TN Rapid, High Resolution Analysis of Aflatoxin Extracts from Peanut Butter Using Kinetex Core-Shell Technology and Strata SPE APPLICATINS Rapid, High Resolution Analysis of Aflatoxin Extracts from Peanut Butter Using Kinetex Core-Shell Technology and Strata SPE Sky Countryman, Shahana Huq, Terrell Mathews, et al. Phenomenex,

More information

Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites

Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites Valérie Thibert 1, Norbert Dirsch 2, Johannes Engl 2, Martin Knirsch 2 1 Thermo Fisher Scientific,

More information

Overview. Introduction. Experimental. Cliquid Software for Routine LC/MS/MS Analysis

Overview. Introduction. Experimental. Cliquid Software for Routine LC/MS/MS Analysis A Fast and Sensitive LC/MS/MS Method for the Quantification and Confirmation of 3 Benzodiazepines and Nonbenzodiazepine Hypnotics in Forensic Urine Samples Cliquid Software for Routine LC/MS/MS Analysis

More information

Drug Adherence Assessment Report

Drug Adherence Assessment Report Prescribed Medications: Drug Adherence Assessment Report FENTANYL, OXYCODONE CONSISTENT RESULTS - REPORTED MEDICATION DETECTED (PARENT DRUG AND/OR METABOLITE) REPORTED ANTICIPATED TEST PRESCRIPTION (S)

More information

CANNABIS TESTING ACCESSORIES

CANNABIS TESTING ACCESSORIES CANNABIS TESTING ACCESSORIES HPLC/GC/Sample Prep www.phenomenex.com/cannabis Popular Accessories for Cannabis Testing Cannabis Testing Accessories Sample Preparation Vials Sample Preparation Phenex Syringe

More information

C30 ISOMERS HAVE MET THEIR MATCH

C30 ISOMERS HAVE MET THEIR MATCH C30 ISOMERS HAVE MET THEIR MATCH INTRODUCING THE NEW! Built on proven Fused-Core particle technology, the is designed to deliver fast separations ideal for lipids and isomers compared to your C18. FEATURES

More information

CLINICAL RESEARCH APPLICATIONS GUIDE

CLINICAL RESEARCH APPLICATIONS GUIDE CLINICAL RESEARCH APPLICATINS GUIDE More throughput Greater sensitivity Reduced costs Less downtime Your job has never demanded more from you. Doctors need accurate results yesterday. You need to minimize

More information

Validation of a Benzodiazepine and Z-Drug Method Using an Agilent 6430 LC/MS/MS

Validation of a Benzodiazepine and Z-Drug Method Using an Agilent 6430 LC/MS/MS Validation of a Benzodiazepine and Z-Drug Method Using an Agilent 6430 LC/MS/MS Application Note Forensics Authors Jason Hudson, Ph.D., James Hutchings, Ph.D., and Rebecca Wagner, Ph.D. Virginia Department

More information

Modernizing the Forensic Lab with LC-MS/MS Technology

Modernizing the Forensic Lab with LC-MS/MS Technology Modernizing the Lab with LC-MS/MS Technology Innovative SCIEX Analytical Tools for the Rapid Identification of Drugs of Abuse in Samples Oscar G. Cabrices 1, Holly McCall 1, Xiang He 1, Alexandre Wang

More information

A New Era in SFC Column Technology

A New Era in SFC Column Technology B TM A ew Era in SFC Column Technology Combining state-of-the-art media manufacturing with the industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC) columns bring a new level

More information

Urine Opioid Dependency Panel (UODP) 1

Urine Opioid Dependency Panel (UODP) 1 Drug Testing Panels Urine Opioid Dependency Panel (UODP) 1 Amphetamines Amphetamine Methamphetamine Methylenedioxyamphetamine Adderall, Dexedrine, Vyvanse, Lisdexamfetamine (Speed, Bennies, Crystal Meth,

More information

Applications of High Resolution Mass Spectrometry in Forensic Toxicology. Patrick Kyle, PhD.

Applications of High Resolution Mass Spectrometry in Forensic Toxicology. Patrick Kyle, PhD. Applications of High Resolution Mass Spectrometry in Forensic Toxicology Patrick Kyle, PhD pkyle@umc.edu Financial Disclosures Grant/Research Support: None Salary/Consultant Fees: None Board/Committee/Advisory

More information

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis Application Note AN784 Extraction of Multiple Mycotoxins from Nuts Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis This application note

More information

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis Application Note AN782 Extraction of Multiple Mycotoxins from Grain Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis This application

More information